SECTION 03600<br />

GROUTING STEEL BASE PLATES<br />

PART 1 - GENERAL<br />

1.01. SUMMARY<br />

A. Section Includes<br />

1. Grout for steel baseplates<br />

1.02. REFERENCE STANDARDS<br />

A. American Society for Testing and Materials:<br />

1. ASTM C1090, Standard Test Method for Measuring Changes in Height of Cylindrical Specimens from<br />

Hydraulic Cement Grout<br />

2. ASTM C1107, Standard Specification for Packaged Dry, Hydraulic-Cement Grout (Non-Shrinkable)<br />

B. Corps of Engineers:<br />

1. CRD-C621, Specification for Non-Shrink Grout.<br />

1.03. SUBMITTALS<br />

A. Product Data: submit manufacturer's data indicating product compliance for the following:<br />

1. Non-shrink grout.<br />

B. Recycled Content:<br />

1. Indicate recycled content; indicate percentage of pre-consumer and post-consumer recycled content per<br />

unit of product.<br />

2. Indicate material cost of product less labor included in project.<br />

3. If recycled content product is part of an assembly, indicate the percentage of recycled content product in<br />

the assembly by weight.<br />

C. Local / Regional Materials:<br />

1. Sourcing location(s): Indicate location of extraction, harvesting, and recovery; indicate distance between<br />

extraction, harvesting, and recovery and the project site.<br />

2. Manufacturing location(s): Indicate location of manufacturing facility; indicate distance between<br />

manufacturing facility and the project site.<br />

3. Product Value: Indicate dollar value of product containing local/regional materials; include materials cost<br />

only.<br />

4. Product Component(s) Value: Where product components are sourced or manufactured in separate<br />

locations, provide location information for each component. Indicate the percentage by weight of each<br />

component per unit of product.<br />

D. Submit information on EPA Waste Minimization Priority Chemicals associated with products provided under<br />

work of this Section. For each Priority Chemical, indicate whether the Priority Chemical is produced as a byproduct<br />

during manufacture and whether it is contained in the final product. Indicate amount produced during<br />

manufacture and the amount contained in final product in terms of percentage by weight per unit of product.<br />

1.04. DELIVERY, STORAGE AND HANDLING<br />

A. Store grout materials in dry condition above ground.<br />

PART 2 - PRODUCTS<br />

2.01. MATERIALS<br />

A. Non-Shrink Grout:<br />

1. Pre-mixed non-shrinking, high strength grout.<br />

2. Compressive strength in 28 days: 5000 psi minimum, but not less than specified strength of base<br />

concrete.<br />

3. Comply with ASTM C1107, and CRD-C621.<br />

4. Non-oxidizing, if grout will be permanently exposed to view.<br />

5. Exhibits positive expansion when testing in accordance with ASTM C1090.<br />

6. Acceptable products:<br />

a. Euco N-S Grout, manufactured by Euclid Chemical Co.<br />

b. Masterflow 713, manufactured by Master Builders Co.<br />

NAPA CENTURY CENTER XD 12<br />