Section 03411<br />

Page 3<br />

1. Warpage: Not to exceed one-eighth (1/8) inch per six (6) feet of length.<br />

2. Linear Shrinkage: Shrinkage in any dimension shall not exceed plus or minus one-eighth (1/8) inch.<br />

3. Squareness: No unit shall be more than one-eighth (1/8) inch in six (6) feet out of square.<br />

4. Location of Inserts: In locations shown on drawings without any deviations.<br />

5. Reinforcing: Within plus or minus one-fourth (1/4) inch of the position given on shop drawings.<br />

3.06. CURING AND PROTECTION<br />

A. Protect freshly placed concrete from washing by rain, flowing water, etc. Do not allow the concrete to dry out<br />

from the time it is deposited in the forms until the expiration of the curing period. Finished surfaces shall be<br />

cured with black polyethylene film secured tightly to the form to prevent evaporation of moisture. In no case<br />

shall the covering be removed before a period of at least seven (7) days has elapsed after the placing and<br />

finishing of the concrete. Curing liquid, if used, shall be applied in accordance with the recommendations of<br />

the manufacturer of the material approved for use, and to sufficient extent to effectively hold the moisture in<br />

the concrete.<br />

3.07. LIFTING AND ERECTION OF PANELS<br />

A. The Contractor shall not lift panels out of forms until the panels have gained a compressive strength of 2500<br />

psi. Panels shall be stored and cured in a flat position to prevent warpage.<br />

B. The panels shall be sufficiently braced until attached to the floor and roof structural assemblies. Panels shall<br />

be accurately positioned and plumbed before welding connection plates and expansion joint material shall be<br />

cemented to the end face of an erected panel before the adjacent panel is set. All lifting and erection shall be<br />

accomplished in a neat and workmanlike manner to prevent cracking, breaking or damaging panels or other<br />

work in any way.<br />

1. Damaged Panels: Any panels showing defects of any kind shall be set only at the risk of the Contractor.<br />

All defects shall be repaired to the satisfaction of the Architect, or shall be replaced; to the end that all<br />

panels, upon completion of the work, be acceptable in every detail.<br />

2. Setting: Set panels and anchor to the structure as detailed on the Drawings.<br />

3.08. TEMPORARY BRACING OF PANELS<br />

A. Provide temporary bracing for panels to resist lateral wind pressures required by the Building Code. Bracing<br />

shall remain in place until permanent structural bracing system is installed and connections are complete.<br />

END OF SECTION<br />