<strong>Buffalo</strong> <strong>Wild</strong> <strong>Wings</strong><br />

1.04 QUALITY ASSURANCE<br />

A. Perform in accordance with ASTM C 840. Comply with requirements of GA-600 for fire-rated<br />

assemblies.<br />

B. Applicator Qualifications: Company specializing in performing gypsum board application and<br />

finishing.<br />

PART 2 PRODUCTS<br />

2.01 METAL FRAMING MATERIALS<br />

A. Non-Loadbearing Framing System Components: ASTM C 645; galvanized sheet steel, of size<br />

and properties necessary to comply with ASTM C 754 for the spacing indicated, with maximum<br />

deflection of wall framing of L/240 at 5 psf.<br />

1. Exception: The minimum metal thickness and section properties requirements of ASTM C<br />

645 are waived provided steel of 40 ksi minimum yield strength is used, the metal is<br />

continuously dimpled, the effective thickness is at least twice the base metal thickness, and<br />

maximum stud heights are determined by testing in accordance with ASTM E 72 using<br />

assemblies specified by ASTM C 754.<br />

2. Studs: "C" shaped with flat or formed webs with knurled faces.<br />

3. Runners: U shaped, sized to match studs.<br />

4. Insulation Furring: Z shaped for use with board insulation, 1 1/2 inch.<br />

B. Partition Head To Structure Connections: Provide track fastened to structure with legs of<br />

sufficient length to accommodate deflection, for friction fit of studs cut short and fastened as<br />

indicated on drawings.<br />

C. Partition Head to Structure Connections: Provide mechanical anchorage devices that<br />

accommodate deflection using slotted holes, screws and anti-friction bushings, preventing<br />

rotation of studs while maintaining structural performance of partition.<br />

1. Structural Performance: Maintain lateral load resistance and vertical movement capacity<br />

required by applicable code, when evaluated in accordance with AISI North American<br />

Specification for the Design of Cold-Formed Steel Structural Members.<br />

2. Material: ASTM A 653/A 653M steel sheet, SS Grade 50/340, with G60/Z180 hot dipped<br />

galvanized coating.<br />

2.02 SUSPENDED CEILING COMPONENTS<br />

A. Hanger Wire: ASTM A 641/A 641M, Class 1 zinc coating, soft temper, 12 gauge wire.<br />

B. Flat Hangers: Steel sheet, 1 by 3/16 inch.<br />

C. Tie Wire: ASTM A 641/A 641M, Class 1 zinc coating, soft temper, 18 gauge wire.<br />

D. Ceiling Channels: 0.0312-inch, (20 Gauge) base metal thickness, with minimum 1/2-inch wide<br />

flanges.<br />

1. Depth: 2-1/2 inch.<br />

E. Furring Channels: Hat-Shaped, 2-9/16 inch wide with 1-1/4 inch face.<br />

1. Minimum Base Metal Thickness: 0.0179 inch, (25 Gauge).<br />

2. Depth: 7/8 inch or 1-1/2 inch, as indicated on Drawings.<br />

2.03 GYPSUM BOARD MATERIALS<br />

A. Acceptable Manufacturers:<br />

1. G-P Gypsum Corporation: www.gp.com.<br />

2. National Gypsum Company: www.nationalgypsum.com.<br />

3. USG Corporation: www.usg.com.<br />

4. Substitutions: See Section 01600 - Product Requirements.<br />

04-27-11 GYPSUM BOARD ASSEMBLIES<br />

09260 -2