2.02 ACCESSORIES<br />

A. Fasteners: Galvanized steel, with soft neoprene washers.<br />

B. Primer: Zinc chromate type.<br />

C. Protective Backing Paint: Zinc alkyd.<br />

D. Sealant: (SLNT6) specified in Section 07900.<br />

E. Bituminous Plastic Cement: ASTM D 4586, Type I. Verify compatibility with roofing membrane<br />

2.03 REGLETS<br />

A. Reglets: Recessed and surface mounted types for concrete and unit masonry applications; 26<br />

gauge galvanized steel.<br />

1. Recessed Reglet: Type MA reglet with Springlok Flashing.<br />

2. Surface Mounted Reglet: Type SM reglet with Springlok Flashing and 7/8” diameter,<br />

stainless steel washers with neoprene facing.<br />

B. Acceptable Manufacturers and Product:<br />

1. Fry Reglet Corporation: Springlok Reglets and Flashing System.<br />

2.04 FABRICATION<br />

A. Form sections true to shape, accurate in size, square, and free from distortion or defects.<br />

B. Form pieces in longest possible lengths.<br />

C. Hem exposed edges on underside 1/2 inch; miter and seam corners.<br />

D. Form material with flat lock seams, except where otherwise indicated. At moving joints, use<br />

sealed lapped, bayonet-type or interlocking hooked seams.<br />

E. Fabricate corners from one piece with minimum 18 inch long legs; seam for rigidity, seal with<br />

sealant.<br />

F. Fabricate vertical faces with bottom edge formed outward 1/4 inch (6 mm) and hemmed to form<br />

drip.<br />

G. Fabricate flashings to allow toe to extend 2 inches over roofing gravel. Return and brake edges.<br />

2.05 SCUPPER FABRICATION<br />

A. Scuppers: Fabricate to dimensions and configurations shown on the Drawings.<br />

B. Seal metal joints.<br />

2.06 MULTI-PIPE ROOF PENETRATIONS<br />

A. Fabricate hooded sheet metal enclosure at multiple roof penetrations. Do not use pitch pockets.<br />

1. Fabricate enclosure of proper size to accommodate pipes, insulation and necessary work<br />

clearances.<br />

2. Pipe penetrations shall be through the side of the exterior of the enclosure and shall occur<br />

a minimum of 8 inches above the roof membrane.<br />

3. Provide sloping sheet metal top on enclosure with hemmed drip edges on all sides and<br />

extended overhang a minimum of 6 inches on the side where pipe penetrations occur.<br />

4. Coordinate with Section 06100 for required curbing.<br />

PART 3 EXECUTION<br />

3.01 EXAMINATION<br />

A. Verify roof openings, curbs, pipes, sleeves, ducts, and vents through roof are solidly set, reglets<br />

in place, and nailing strips located.<br />