SECTION 07212 - BOARD AND BATT INSULATION<br />

PART 1 GENERAL<br />

1.01 SECTION INCLUDES<br />

A. Batt insulation in exterior wall construction.<br />

B. Batt insulation for filling perimeter window and door shim spaces, crevices in exterior wall and<br />

roof, and roof and miscellaneous stud spaces.<br />

C. Batt insulation for acoustic insulation in interior partitions.<br />

D. Board Insulation at roof.<br />

E. Board Insulation for exterior foundations.<br />

1.02 RELATED SECTIONS<br />

A. Section 05400 - Cold Formed Metal Framing: Supporting construction for batt insulation.<br />

B. Section 06100 – Rough Carpentry.<br />

C. Section 07260 – Air and Vapor Barriers.<br />

D. Section 07535 - Mechanically Attached Membrane Roofing.<br />

1.03 REFERENCES<br />

A. ASTM C 665 - Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light<br />

Frame Construction and Manufactured Housing.<br />

B. ASTM E 136 - Standard Test Method for Behavior of Materials in a Vertical Tube Furnace At<br />

750 Degrees C.<br />

C. ASTM C 578 – Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation.<br />

D. ASTM C 1289 - Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal<br />

Insulation Board.<br />

E. ASTM D 1621 - Standard Test Method for Compressive Properties Of Rigid Cellular Plastics.<br />

F. ASTM D 1622 - Standard Test Method for Apparent Density of Rigid Cellular Plastics.<br />

G. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials.<br />

1.04 QUALITY ASSURANCE<br />

A. Source Limitations: Obtain each type of building insulation through one source from a single<br />

manufacturer.<br />

B. Verify that polyisocyanurate roof insulation is acceptable with roof membrane manufacturer.<br />

Refer to Section 07535.<br />

1.05 DELIVERY, STORAGE, AND HANDLING<br />

A. Protect insulation materials from physical damage and from deterioration by moisture, soiling,<br />

and other sources. Store inside and in a dry location. Comply with manufacturer's written<br />

instructions for handling, storing, and protecting during installation.<br />

03/09/10 BOARD AND BATT INSULATION<br />