05.03.2015 Views

GSX CURVED BLADES SWIRL DIFFUSERS - Madel

GSX CURVED BLADES SWIRL DIFFUSERS - Madel

GSX CURVED BLADES SWIRL DIFFUSERS - Madel

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>GSX</strong> <strong>CURVED</strong> <strong>BLADES</strong> <strong>SWIRL</strong> <strong>DIFFUSERS</strong><br />

Rotational diffuser of the series <strong>GSX</strong> are designed to be applied in air conditioning,<br />

ventilation and heating.<br />

They are mounted in false ceilings or hanging.<br />

The design of its plates and their disposition in four sectors cause a rotational<br />

impulsion of the air with a Coanda effect, obtaining a high induction index and<br />

a stratification reduction.<br />

Its vanes make possible the graduation of the air impulsion horizontally for cold<br />

air or vertically for hot air.<br />

These diffusers are made to be used from 2.6 m. up to high heights, with a<br />

temperature differential up to 10º C, obtaining a high performance in the sound<br />

pressure level in the comfort zone.<br />

1 09/04


CLASSIFICATION<br />

<strong>GSX</strong> Diffuser with individually adjustable<br />

vanes arranged in four sectors with<br />

different directions, in order to give a<br />

rotational effect to the air stream.<br />

MATERIAL<br />

Diffuser made of extruded aluminium.<br />

All diffusers have a joint on the rear side<br />

to achieve an airtight sealing all around<br />

the perimeter in contact with the plenum.<br />

ADDITIONAL ACCESSORIES<br />

PLSX Plenum box with a lateral circular<br />

connection for square diffusers. It<br />

includes supports to hang from the<br />

ceiling.<br />

Made in galvanised steel.<br />

…-R Plenum box with a flow damper in<br />

the spigot.<br />

…/S/ Plenum box with an upper circular<br />

neck connector.<br />

…/AIS/ Plenum thermo acoustically<br />

insulated by means of foam with a<br />

coefficient of thermal conductivity of 0,04<br />

w/mk.<br />

The said foam meets the fire reaction<br />

standards:<br />

UNE 23-727 M2<br />

NFP 92-501 M2<br />

DIN 4102 M2<br />

2 09/04


FIXING SYSTEMS<br />

1) Connection into the PLSX plenum<br />

box by means of central screw, to hang<br />

the assembly from the ceiling with drops<br />

rods.<br />

1) Connection into the PMSX crossbar<br />

by means of central screw. Suitable for<br />

mounting in false ceiling with rectangular<br />

duct. Constructed in galvanised steel.<br />

FINISHES<br />

AA Anodised in matt silver.<br />

RAL… Lacquer in other colours (RAL<br />

specifications).<br />

3 09/04


<strong>GSX</strong><br />

SERIES<br />

RECOMMENDED VELOCITY.<br />

<strong>GSX</strong> Vmin<br />

m/s<br />

Vmax<br />

m/s<br />

400 2.5 4.5<br />

600 2.5 4.5<br />

V k ( m / s )<br />

9<br />

8<br />

7<br />

6<br />

5<br />

NECK VELOCITY.<br />

<strong>GSX</strong>-400<br />

<strong>GSX</strong>-600<br />

4<br />

NECK AREA m2.<br />

3<br />

<strong>GSX</strong><br />

400<br />

600<br />

Ak<br />

0,07<br />

0,16<br />

Qmin<br />

m3/h<br />

Qmax<br />

m3/h<br />

630 1134<br />

1440 2592<br />

2<br />

1<br />

300 500 700 800 1000 12501500 2000 2500 3000 4000<br />

Q ( m<br />

3<br />

/ h )<br />

PRESSURE LOSS AND SOUND POWER LEVEL.<br />

Pt<br />

DPt ( Pa )<br />

100<br />

75<br />

50<br />

40<br />

30<br />

20<br />

15<br />

Lwa1=(dB(A))<br />

40 45 50<br />

30 35<br />

<strong>GSX</strong>-400<br />

<strong>GSX</strong>-600<br />

10<br />

25<br />

5<br />

2<br />

300<br />

500<br />

700 800<br />

1000 12501500 2000 2500 3000<br />

3<br />

Q ( m / h )<br />

4000<br />

4<br />

<strong>GSX</strong>-GR1-09/04


<strong>GSX</strong> SERIES<br />

A B B C<br />

ALv 0,2 (m)<br />

ALv 0,2 ( m)<br />

1,8<br />

H<br />

ALh<br />

ALh<br />

ALh<br />

0,2<br />

0,2<br />

0,2<br />

(m) = A<br />

(m) = B + H<br />

(m) = C + H<br />

ISOTHERM TRHOW.<br />

<strong>GSX</strong> 400<br />

AL h<br />

300 500 700 800 1000 12501500 2000 2500 3000<br />

3<br />

1<br />

Q (m /h)<br />

2<br />

3 4 5 6 7 8 10 1214 17 20<br />

Horizontal throw, ALh 0,2 (m).<br />

MAXIMUM VERTICAL DEPTH IN HEATING.<br />

- + 0<br />

5<br />

+<br />

+10<br />

+15<br />

AL v<br />

<strong>GSX</strong> 400<br />

= 45<br />

60<br />

75<br />

90<br />

300<br />

500<br />

700 800 1000 12501500 2000 2500 3000<br />

3<br />

1<br />

Q (m /h)<br />

2 3 4 5 6 7 8 10 1214 17 20<br />

Vertical throw, ALv 0,2 (m).<br />

5<br />

<strong>GSX</strong>-GR2-09/04


<strong>GSX</strong> SERIES<br />

ISOTHERM TRHOW.<br />

<strong>GSX</strong> 600<br />

AL h<br />

300<br />

500<br />

700<br />

800 1000 12501500 2000 2500<br />

3<br />

Q (m /h)<br />

3000<br />

1<br />

2 3 4 5 6 7 8 10 1214 17 20<br />

Horizontal throw, ALh 0,2 (m).<br />

MAXIMUM VERTICAL DEPTH IN HEATING.<br />

<strong>GSX</strong> 600<br />

- + 0<br />

+15<br />

+5<br />

+10<br />

AL v<br />

= 45<br />

60<br />

75<br />

90<br />

300 500 700 800 1000 12501500 2000 2500 3000 2 3 4 5 6 7 8 10 1214 17 20<br />

3<br />

1<br />

Q (m /h)<br />

Vertical throw, ALv 0,2 (m).<br />

6<br />

<strong>GSX</strong>-GR3-09/04

Hooray! Your file is uploaded and ready to be published.

Saved successfully!