05.03.2015 Views

New Generation Auto-Injectors - DALI Medical Devices

New Generation Auto-Injectors - DALI Medical Devices

New Generation Auto-Injectors - DALI Medical Devices

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

International Patents Pending<br />

<strong>New</strong> <strong>Generation</strong><br />

<strong>Auto</strong>-<strong>Injectors</strong><br />

for Drugs in<br />

Prefilled Syringes or Vials<br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

The Universe of Pre-filled Syringes and Injection <strong>Devices</strong><br />

Oct 23-25, 2006<br />

Presentation Outline<br />

• Introduction – ELCAM and <strong>DALI</strong><br />

• <strong>New</strong> <strong>Generation</strong> Disposable <strong>Auto</strong>-<strong>Injectors</strong> –<br />

Features<br />

• Proof-of-Concept Studies:<br />

Disposable <strong>Auto</strong>-<strong>Injectors</strong> for Drugs in<br />

Vials / Prefilled Syringes:<br />

– Usability Study: from problem to solution<br />

– In-vivo Animal Study<br />

• Other Platforms (SEDAI, <strong>Auto</strong>-Needle …)<br />

2 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

1


Product Lines<br />

• Stopcocks<br />

• Manifolds<br />

• Needle-less<br />

• Valves<br />

• Disposable Pressure Transducers<br />

• I3D—<strong>Auto</strong>-<strong>Injectors</strong><br />

3<br />

Elcam <strong>Medical</strong> Facility<br />

• 27,000 sq. ft. of class 100,000 clean rooms<br />

• Second facility to open in mid-year 2007<br />

• Precision injection molding processes –<br />

including 2C<br />

• Fully automated production floor utilizing<br />

custom made assembly machines<br />

4<br />

2


Elcam’s Partners<br />

• Arrow<br />

• Baxter<br />

• Edwards<br />

• Sicor Pharmaceuticals<br />

• Hospira<br />

• Abbott<br />

• B. Braun<br />

• St. Jude<br />

• U.S. Surgical<br />

• Cardinal Health<br />

• Applied <strong>Medical</strong><br />

• Medtronic<br />

• Utah <strong>Medical</strong><br />

• Cook<br />

• ICU <strong>Medical</strong><br />

• Bard<br />

• Argon<br />

5<br />

<strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

• <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong> brings over 15 years of<br />

product development experience<br />

• Over 10 years in the field of <strong>Auto</strong>matic Drug<br />

Delivery <strong>Devices</strong><br />

• Specializing in innovative proprietary Injectable<br />

Drug Delivery <strong>Devices</strong> for self-administration<br />

Fully-Disposable <strong>Auto</strong>-<strong>Injectors</strong><br />

(FUDAI)<br />

Semi-Disposable <strong>Auto</strong>-Injector<br />

(SEDAI)<br />

<strong>Auto</strong>matic-Needle<br />

(AN)<br />

6 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

3


<strong>New</strong> <strong>Generation</strong> Disposable<br />

<strong>Auto</strong>-<strong>Injectors</strong> – Features<br />

Fully-Disposable<br />

<strong>Auto</strong>-Injector<br />

for<br />

Drugs in Vials<br />

(FUDAI DV)<br />

• Safe & Simple<br />

• Less Pain<br />

• Injection starts only after<br />

full needle penetration<br />

• Easy drug reconstitution<br />

and aspiration from vials<br />

• Single or multiple vials<br />

Fully-Disposable<br />

<strong>Auto</strong>-Injector<br />

for<br />

Pre-filled Syringe<br />

(FUDAI PFS)<br />

7 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

FUDAI DV Usability Case Study:<br />

from problem to solution<br />

Background<br />

• Developed with a major pharmaceutical company<br />

• Drug in vial (expensive)<br />

• Generally elderly patient population (50-75 years)<br />

• Frequent or infrequent injections<br />

• Market transition from injection by healthcare<br />

providers to self-injection at home<br />

• Design Concept: a Plunger Rod is used to fill the<br />

drug from the vial into the injector<br />

8 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

4


FUDAI DV Usability Case Study:<br />

from problem to solution<br />

Device Used in the Study<br />

• Note Plunger tip design<br />

• Note no Device Labeling was used<br />

9 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

FUDAI DV Usability Case Study:<br />

from problem to solution<br />

The Problem<br />

• In a usability study performed in the US with 28<br />

participants, occasionally, some people pushed on<br />

the Plunger Rod instead of pressing the Inject<br />

Button for activation (while not looking at the<br />

instructions for use)<br />

• Result: Spillage of expensive drug<br />

Oops… What do<br />

we do now???<br />

10 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

5


FUDAI DV Usability Case Study:<br />

from problem to solution<br />

The Way to Solution<br />

• About 40 solutions were screened…<br />

• From which 4 reached the ―finals‖….<br />

Parameters Considered:<br />

Usability, Manufacturability, COGS, Timeline<br />

11 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

FUDAI DV Usability Case Study:<br />

from problem to solution<br />

The Way to Solution<br />

• Chosen Solution…<br />

12 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

6


FUDAI DV Usability Case Study:<br />

from problem to solution<br />

The “Elizabeth Show”:<br />

A 70 years old lady with<br />

Essential Tremor<br />

operating the FUDAI DV<br />

An Example for a<br />

Successful Operation<br />

13 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

FUDAI DV Usability Case Study:<br />

from problem to solution<br />

Lessons Learned<br />

• Whatever you think users will do – they would find<br />

a way to make it even worse…<br />

• Device labels can make the difference<br />

• Perform as many usability trials as possible<br />

• NOTE: There is always a better way / easy way to<br />

do it – it’s just a matter of time and money<br />

14 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

7


In-vivo Animal Case Study:<br />

successfully performed as expected<br />

Injection into Pig - Example from X-Ray video<br />

• 0.5 mL or 1.0 mL<br />

• 6 injections /<br />

device / volume<br />

15 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

In-vivo Animal Case Study:<br />

successfully performed as expected<br />

Before Activation<br />

0.00 sec.<br />

Needle Penetration<br />

0.04 sec.<br />

Drug Injection<br />

0.08 sec.<br />

16 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

8


In-vivo Animal Case Study:<br />

successfully performed as expected<br />

Conclusions<br />

In-vivo injection with the injectors (FUDAI, SEDAI, AN)<br />

work as expected:<br />

√ Full needle penetration<br />

√ Complete SC dose injection<br />

√ MOST IMPORTANT: Injection performed with the<br />

FUDAI / SEDAI starts ONLY AFTER full needle<br />

penetration is achieved<br />

X<br />

17 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

<strong>New</strong> <strong>Generation</strong> Disposable<br />

<strong>Auto</strong>-<strong>Injectors</strong> – Features<br />

Fully-Disposable<br />

<strong>Auto</strong>-Injector<br />

for<br />

Drugs in Vials<br />

(FUDAI DV)<br />

• Safe & Simple<br />

• Less Pain<br />

• Injection starts only after<br />

full needle penetration<br />

• Easy drug reconstitution<br />

and aspiration from vials<br />

• Single or multiple vials<br />

Fully-Disposable<br />

<strong>Auto</strong>-Injector<br />

for<br />

Pre-filled Syringe<br />

(FUDAI PFS)<br />

18 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

9


Thank you for your attention<br />

and for waking up so early…<br />

See us also at the<br />

AAPS Annual Meeting<br />

San Antonio, TX<br />

Booth: 2091<br />

Contact (Head Office):<br />

Dr. Menachem Zucker<br />

VP Marketing, Sales & Business Development<br />

Elcam <strong>Medical</strong><br />

Kibbutz Bar’Am, 13860, Israel<br />

Tel: +972-4-698 8890 (Direct)<br />

+972-4-698 8120<br />

Fax: +972-4-698 0777<br />

Email: menachem@elcam.co.il<br />

www.elcam-medical.com<br />

Contact (USA):<br />

Lloyd Fishman<br />

VP Marketing & Business Development<br />

Elcam <strong>Medical</strong> Inc.<br />

2 University Plaza, Suite 620<br />

Hackensack, NJ 07601, USA<br />

Tel: 201-457 1120 (x 103)<br />

Fax: 201-457 1125<br />

Email: lloyd.fishman@elcam-medical.com<br />

www.elcam-medical.com<br />

Contact:<br />

David Daily<br />

CEO<br />

<strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

2 Rojanski St’, <strong>New</strong> Ind. Zone<br />

Rishon LeZion 75706, Israel<br />

Tel: +972-3-951 9675<br />

Fax: +972-3-951 9649<br />

Email: ddaily@dalimed.com<br />

10


Drug injection<br />

0.08 sec.<br />

21 David Daily, <strong>DALI</strong> <strong>Medical</strong> <strong>Devices</strong><br />

Lloyd Fishman, ELCAM <strong>Medical</strong><br />

October 25, 2006<br />

Universe of PFS & Injection <strong>Devices</strong><br />

11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!