LEGEND<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
AP<br />
TM<br />
FOIL FACED SHEATHING<br />
FLASHING TAPE<br />
THROUGH-WALL FLASHING INTERFACED W/ AIR BARRIER TO PROVIDE A SHINGLE AFFECT.<br />
TYPE 1 VAPOR BARRIER.<br />
MOISTURE BARRIER UP TO LEVEL OF GRADE.<br />
OPTIONAL EXTERIOR SHEATHING.<br />
FOAM GASKET<br />
6<br />
1<br />
2<br />
7<br />
3 4<br />
1<br />
5<br />
SKETCH NO. SCALE ISSUE DATE<br />
REV. NO.<br />
CAD FILE:<br />
06/27/13<br />
FLOOR SLAB TO FOUNDATION.dwg
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
AP<br />
TM<br />
FOIL FACED SHEATHING<br />
FLASHING TAPE<br />
THROUGH-WALL FLASHING.<br />
AIRTIGHT GASKET BETWEEN WALL PLATE & SUBFLOOR. SEAL FLOOR JOINTS.<br />
SEALANT BETWEEN SUBFLOOR & RIM JOIST.<br />
FOAM GASKET.<br />
MOISTURE BARRIER UP TO LEVEL OF GRADE.<br />
APPROVED SEALANT<br />
9<br />
OPTIONAL EXTERIOR SHEATHING<br />
8<br />
9<br />
5<br />
4<br />
2<br />
1<br />
6<br />
2<br />
3<br />
6<br />
7<br />
1<br />
SKETCH NO. SCALE ISSUE DATE<br />
REV. NO.<br />
CAD FILE:<br />
06/27/13
LEGEND<br />
1<br />
2<br />
3<br />
4<br />
5<br />
AP<br />
TM<br />
FOIL FACED SHEATHING<br />
FLASHING TAPE<br />
OPTIONAL EXTERIOR SHEATHING.<br />
FLASHING TAPE<br />
OPTIONAL CAVITY INSULATION<br />
1<br />
2<br />
1<br />
3<br />
3<br />
5<br />
SKETCH NO. SCALE ISSUE DATE<br />
REV. NO.<br />
CAD FILE:<br />
06/27/13<br />
WALL CORNER (PLAN).dwg
LEGEND<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
AP<br />
TM<br />
FOIL FACED SHEATHING<br />
SEALANT BEAD & BACKER ROD AROUND WINDOW CASING<br />
FLASHING TAPE<br />
SEALANT BEAD & BACKER ROD<br />
OPTIONAL EXTERIOR SHEATHING<br />
APPROVED SEALANT<br />
OPTIONAL CAVITY INSULATION<br />
2<br />
4<br />
4<br />
3<br />
6<br />
1<br />
5<br />
7<br />
SKETCH NO. SCALE ISSUE DATE<br />
REV. NO.<br />
3"=1'-0"<br />
CAD FILE:<br />
06/27/13<br />
WINDOW SILL.dwg
LEGEND<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
AP<br />
TM<br />
FOIL FACED SHEATHING<br />
SEALANT BEAD & BACKER ROD<br />
FLASHING TAPE<br />
THROUGH-WALL FLASHING<br />
OPTIONAL EXTERIOR SHEATHING<br />
APPROVED SEALANT<br />
5<br />
6<br />
1<br />
3<br />
4<br />
2<br />
2<br />
SKETCH NO. SCALE ISSUE DATE<br />
REV. NO.<br />
3"=1'-0"<br />
CAD FILE:<br />
06/27/13<br />
WINDOW HEAD.dwg
LEGEND<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
AP<br />
TM<br />
FOIL FACED SHEATHING<br />
VAPOR BARRIER WHEN REQUIRED BY LOCAL JURISDICTION<br />
ROOFING MEMBRANE<br />
ROOFING SYSTEM FULLY BONDED TO FLASHING COVERING PARAPET FRAME<br />
OPTIONAL EXTERIOR SHEATHING<br />
FLASHING TAPE BONDED TO ROOFING SYSTEM (CONTINUITY W/ PLANE OF AIR TIGHTNESS)<br />
APROVED SEALANT<br />
4<br />
6<br />
7<br />
3<br />
2<br />
5<br />
1<br />
SKETCH NO. SCALE ISSUE DATE<br />
REV. NO.<br />
CAD FILE:<br />
06/27/13<br />
PARAPET DETAIL.dwg
LEGEND<br />
1<br />
2<br />
3<br />
4<br />
AP<br />
TM<br />
FOIL FACED SHEATHING<br />
FLASHING TAPE<br />
CAULK & BACKER ROD<br />
OPTIONAL EXTERIOR SHEATHING<br />
3<br />
2<br />
1<br />
4<br />
SKETCH NO. SCALE ISSUE DATE<br />
REV. NO.<br />
3"=1'-0"<br />
CAD FILE:<br />
06/27/13<br />
EXPANSION JOINT.dwg
LEGEND<br />
1<br />
2<br />
3<br />
AP<br />
TM<br />
FOIL FACED SHEATHING<br />
EXTERIOR GYPSUM SHEATHING.<br />
BACKER ROD AS NEEDED.<br />
1<br />
2<br />
3<br />
SKETCH NO. SCALE ISSUE DATE<br />
REV. NO.<br />
3"=1'-0"<br />
CAD FILE:<br />
06/27/13<br />
CHANGE IN SUBSTRATE.dwg
LEGEND<br />
1<br />
2<br />
3<br />
4<br />
AP<br />
TM<br />
FOIL FACED SHEATHING<br />
PIPE<br />
APPROVED SEALANT<br />
OPTIONAL EXTERIOR SHEATHING<br />
1<br />
4<br />
3<br />
3<br />
2<br />
3<br />
2<br />
A<br />
A<br />
SKETCH NO. SCALE ISSUE DATE<br />
REV. NO.<br />
3"=1'-0"<br />
CAD FILE:<br />
06/27/13<br />
PENETRATIONS.dwg
LEGEND<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
AP<br />
TM<br />
FOIL FACED SHEATHING<br />
METAL FLANGE<br />
FIRE CAULK<br />
NON COMBUSTIBLE SHEATHING<br />
MINWOOL MINERAL FIBER<br />
OVERSIZED PIPE COLLAR<br />
HIGH TEMPERTURE PIPE<br />
FLASHING TAPE<br />
1<br />
2<br />
3 5 6 7<br />
4<br />
7<br />
3"<br />
3<br />
5<br />
3"<br />
2<br />
8<br />
A<br />
6<br />
8<br />
(TYPICAL)<br />
VIEW AT SURFACE<br />
OF SHEATHING<br />
A<br />
SKETCH NO. SCALE ISSUE DATE<br />
REV. NO.<br />
3"=1'-0"<br />
CAD FILE:<br />
06/27/13<br />
HIGH TEMP PENETRATIONS.dwg
LEGEND<br />
1<br />
2<br />
3<br />
4<br />
5<br />
AP<br />
TM<br />
FOIL FACED SHEATHING<br />
FLOOR STRUCTURE<br />
WALL STRUCTURE<br />
OPTIONAL EXTERIOR SHEATHING<br />
OPTIONAL CAVITY INSULATION<br />
5<br />
3<br />
4<br />
1<br />
2<br />
1<br />
3<br />
4<br />
3<br />
5<br />
STEEL COLUMN PLAN<br />
SKETCH NO. SCALE ISSUE DATE<br />
REV. NO.<br />
3"=1'-0"<br />
CAD FILE:<br />
06/27/13<br />
INTERSTORY CONNECTIONS.dwg
LEGEND<br />
1<br />
2<br />
3<br />
4<br />
AP<br />
TM<br />
FOIL FACED SHEATHING<br />
WALL STRUCTURE.<br />
OPTIONAL EXTERIOR SHEATHING.<br />
JOINT IN EXTERIOR GYPSUM.<br />
1<br />
2<br />
3<br />
4<br />
SKETCH NO. SCALE ISSUE DATE<br />
REV. NO.<br />
3"=1'-0"<br />
CAD FILE:<br />
06/27/13<br />
SUBSTRATE JOINTS & DEFECTS.dwg