Worm Gear Reducers (MRT) - Rotor UK
Worm Gear Reducers (MRT) - Rotor UK
Worm Gear Reducers (MRT) - Rotor UK
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Ratio i<br />
n 2<br />
[rpm]<br />
Ratio i<br />
n 2<br />
[rpm]<br />
Performance data of gear units are shown in the Tables 7.1 to 7.4<br />
Tables 7.1 to 7.3 show max. values of the output torque M k2<br />
and power P 1<br />
with operation factor = 1. The values shown in the<br />
Tables 7.1 to 7.3 also applicable for the RT execution.<br />
Example:<br />
Type<br />
–<br />
i<br />
–<br />
n 1<br />
= 1400 [rpm]<br />
n 2<br />
[rpm<br />
Mk 2<br />
[Nm]<br />
P 1<br />
[kW]<br />
η d<br />
[%]<br />
(M)RT 30A 5 280 16 0.54 87<br />
i – gear ratio<br />
n 1<br />
– input shaft speed<br />
n 2<br />
– output shaft speed<br />
M k2<br />
– output torque<br />
P 1<br />
– rated input power<br />
η d<br />
– dynamic gear unit efficiency<br />
The Table 8.4 shows parameters of <strong>MRT</strong> and MRP gear units with an electric motor classified by power and the output speed.<br />
Example:<br />
P 1<br />
= 0,37 kW n 1<br />
= 1400 [rpm] 71-4p<br />
n 2<br />
[rpm]<br />
i<br />
[–]<br />
M 2<br />
[Nm]<br />
Sf<br />
[–]<br />
Size<br />
–<br />
St. As.<br />
Flange<br />
280 5 11 3.3 <strong>MRT</strong> 40 F40M (85)<br />
187 7,5 16 2.2 <strong>MRT</strong> 40 F40M (85)<br />
P 1<br />
– electric motor power<br />
n 1<br />
– input shaft speed<br />
n 2<br />
– output shaft speed<br />
i – gear ratio<br />
M 2<br />
– output torque<br />
Sf – gear unit service factor<br />
St. As. Flange – standard motor flange fitted – see Table 11.1<br />
9 prior to alterations