DYNINFO Parameter List<br />

28 insufficient length <strong>for</strong> all volumes<br />

32 syntax error (DYNRQDSN all spaces or DYNRQDVC invalid)<br />

GV<br />

Initiates or continues a scan of the Catalog in volser sequence starting at the<br />

first volume whose volser matches the partial key supplied in DYNRQVOL up to<br />

the first blank.<br />

Required fields:<br />

Optional fields:<br />

DYNRQVOL<br />

DYNRQPSW<br />

Return codes:<br />

6 volume is scratch - no active data sets<br />

16 password protected data set<br />

24 no more volumes<br />

32 syntax error (DYNRQVOL all spaces)<br />

NF<br />

Is used after an SV, GV, DV, or NF call to return the next file on a multifile<br />

tape volume without reaccessing the volume in<strong>for</strong>mation. It is functionally<br />

equivalent to a DV with the DYNRQFSQ value incremented by one, but is<br />

significantly faster. DYGFILSQ indicates the actual file sequence number<br />

returned.<br />

Required fields:<br />

Optional fields:<br />

None<br />

None<br />

Return codes:<br />

16 password-protected data set<br />

26 no more files <strong>for</strong> volume<br />

32 syntax error (previous command was not SV, GV, DV, or NF)<br />

NG<br />

Is used after a SD, GD, DD, NX, or NG call to return the next generation <strong>for</strong><br />

the data set without reaccessing the data set in<strong>for</strong>mation. It is functionally<br />

equivalent to a DD call with DYNRQVER incremented by 1, but is significantly<br />

faster. If DYNRQDVC is specified, only data sets and versions of the specified<br />

device class will be returned. If DYNRQVER is nonblank, it will be validated as<br />

a packed field. A valid packed number is assumed to be the number of<br />

versions retrieved <strong>for</strong> this data set so far, and is incremented by one. It is not<br />

used in any other way. Scratched, test and invalid generations are ignored and<br />

do not count in calculating the relative generation number.<br />

Required fields:<br />

Optional fields:<br />

None<br />

DYNRQDVC, DYNRQVER<br />