DYN<strong>CA</strong>T Commands<br />

CIMSG=<br />

Optional parameter. It defines user-specified messages <strong>for</strong> the dataset. These<br />

messages will be issued Open Input (OIMSG=), Open Output (OOMSG=),<br />

Close Input (CIMSG=), and/or Close Output (COMSG=) <strong>for</strong> the dataset, as<br />

specified, and will be directed to the operator console and/or SYSLST as<br />

indicated by the routing code. Routing codes are as follows:<br />

C - Console (default)<br />

P - Printer<br />

B - Both<br />

Valid input is 1 to 70 alphanumeric characters of message text, followed by a<br />

comma, followed by single-character routing code, following optionally by a , A<br />

if message should ring the console. All are enclosed by apostrophes.<br />

Example<br />

OIMSG='MY MESSAGE,C'<br />

OOMSG='MY MESSAGE FOR OUTPUT, C,A'<br />

CLOSE=<br />

Optional parameter that specifies the DTF rewind option set by <strong>CA</strong> <strong>Dynam</strong>/T or<br />

<strong>CA</strong> <strong>Dynam</strong>/FI <strong>for</strong> CLOSE.<br />

NORWD<br />

RWD<br />

UNL<br />

tape is not rewound<br />

<strong>for</strong>ce rewind<br />

<strong>for</strong>ce rewind and unload<br />

COMment=<br />

Optional parameter. Specifies the comment field to be associated with this<br />

dataset. Valid entries are 1 to 100 alphanumeric characters enclosed in<br />

apostrophes.<br />

Note that, even though up to 100 bytes of comment may be specified, the<br />

comment shown on some reports may be truncated due to space limitations.<br />

COMSG=<br />

DEFvlt=<br />

See CIMSG operand description.<br />

Optional parameter. Defines the default vault location <strong>for</strong> all versions of the<br />

dataset not specified by VLTLOC parameter. Normally, the default vault<br />

location is A. Valid entry is:<br />

One alphabetic character in the range A-Z.<br />

If omitted, the main tape vault (A) is assumed.<br />