DYN<strong>CA</strong>T Commands<br />

Note: You must specify KEKL1 if you want to specify KEKL2. If you don’t<br />

specify KEKL2, then the value of KEKL1 is used <strong>for</strong> KEKL2.<br />

KEKL2=<br />

Optional parameter. Defines the KEKL2 specification <strong>for</strong> the dataset. Valid<br />

input is a 1 to 64 character KEKL specification followed by a comma, followed<br />

by a single–character Key Encryption Method. All is enclosed by apostrophes.<br />

Valid Key Encryption Methods are as follows:<br />

L<br />

H<br />

Encode the Key label as the label is specified<br />

Encode the Key label as a hash of the public key<br />

Note: You can specify KEKL2 only if you have specified KEKL1. If you don’t<br />

specify KEKL2, then the value of KEKL1 is used <strong>for</strong> KEKL2.<br />

LENgth=<br />

Optional parameter. Changes the tape length specification <strong>for</strong> this dataset.<br />

Valid entries are:<br />

XS<br />

S<br />

MS<br />

M<br />

ML<br />

L<br />

NO<br />

extra short<br />

short<br />

medium short<br />

medium<br />

medium long<br />

long<br />

removes the length specification.<br />

LOCK|UNLOCK<br />

Optional parameter that prevents or allows access to a specific version of a<br />

dataset or to the entire dataset.<br />

LOCK<br />

If the LOCK function is used <strong>for</strong> a specific version, only<br />

that version will be locked <strong>for</strong> input. New versions may<br />

still be created.<br />

If the LOCK function is used to LOCK the entire dataset, no new versions will<br />

be cataloged, but existing versions will be available to be used as input. If the<br />

entire dataset has been locked and the dataset is used <strong>for</strong> output, the output<br />

will not be cataloged and the output tape is changed from SCRATCH to LOCK<br />

status. The next scratch function will return this tape to SCRATCH status.<br />

No batch maintenance may be per<strong>for</strong>med on a dataset that is LOCKed, except<br />

to UNLOCK it.<br />

UNLOCK<br />

Reverses the effect of the LOCK parameter.<br />

Chapter 8: Maintaining the Catalog−DYN<strong>CA</strong>T Program 8–27