Vault Location Control Program—TDYNVLT<br />

// DLBL WORK2,'WORK.02'<br />

// EXTENT SYS002..........<br />

// ASSGN SYS002,cuu<br />

// EXEC TDYNVLT,SIZE=128K<br />

MOVEMENT<br />

VERIFY<br />

/*<br />

The MOVEMENT function activates the vault movement. The VERIFY function<br />

gets a slot number <strong>for</strong> all volumes whose vault is not rotated and <strong>for</strong> whose<br />

vault location slot support is defined. You can run this first with the DUMMY<br />

option to avoid <strong>CA</strong> <strong>Dynam</strong> Catalog update.<br />

For more in<strong>for</strong>mation about these functions, see TDYNVLT Commands.<br />

Running TDYNVLT<br />

Run TDYNVLT daily or weekly, depending on how often you transfer tapes from<br />

one location to another. By definition, vault location A is the main tape library.<br />

The DYN<strong>CA</strong>T SCRATCH function will scratch expired versions only if they<br />

currently reside in location A. There<strong>for</strong>e, if you run both programs each day,<br />

run TDYNVLT be<strong>for</strong>e DYN<strong>CA</strong>T.<br />

TDYNVLT has the following six phases of execution:<br />

1. Gathers all vaults that will require an automatic verify<br />

2. Collects vault location changes<br />

3. Verifies, frees, and gets slot numbers; also updates the <strong>CA</strong> <strong>Dynam</strong> Catalog<br />

4. Prints movement reports<br />

5. Generates inventory reports<br />

6. Prints the inventory reports<br />

If TDYNVLT cancels <strong>for</strong> any reason during execution, run the DYN<strong>CA</strong>T BACKUP<br />

function to verify the integrity of the Catalog: Vault movement in<strong>for</strong>mation<br />

may have been lost. (DYN<strong>CA</strong>T RESTORE is unnecessary if you are running<br />

TDYNVLT with the DUMMY option, or if the <strong>CA</strong>DT602I message has not been<br />

issued.)<br />

You can activate TDYNVLT functions with control statements. If you do not<br />

submit any control statements, TDYNVLT will end normally unless TDYNVLT<br />

detects that an automatic verify is required. In that case, TDYNVLT continues<br />

as if the VERIFY control statement had been submitted.<br />

Chapter 3: Supporting Tape File Management 3–47