Vault Location Control Program—TDYNVLT<br />

Establishing Vault Locations<br />

To establish the desired location <strong>for</strong> each version of a data set, you can do the<br />

following:<br />

• Specify a location <strong>for</strong> each of the first 999 versions.<br />

• Specify up to 26 different locations.<br />

• Attach to each location, a 77-character description to be printed on the<br />

vault reports.<br />

If a version does not have a specified vault location, TDYNVLT uses the data<br />

set's default vault location.<br />

You can specify the starting version of a data set <strong>for</strong> the vault location by<br />

including the VLTSEQ=nnn parameter with VLTLOC. Vault sequencing lets you<br />

define which of up to 999 versions of a data set has vault control. VLTSEQ<br />

must be used with VLTLOC on a DYN<strong>CA</strong>T ALTER command.<br />

You can also define slot numbers within all vault locations, except vault A.<br />

These slot numbers enable you to further control the vault locations. For each<br />

vault, you can do the following:<br />

• Define up to 10 ranges of slot numbers, with a maximum of 65,536 slots<br />

per range.<br />

• Define and delete slot-number ranges using the DYN<strong>CA</strong>T program.<br />

Defining Slots<br />

To define slots within vaults, use the DYN<strong>CA</strong>T VAULT control statement, as<br />

follows:<br />

VAULT VLTLOC=x [DESC='xxxxx'] SLOTS=(x1,y1)<br />

You can define up to 10 ranges of slot numbers, but only one range per<br />

statement. Each slot range must be uniquely associated with a VLTLOC=<br />

parameter and a VAULT command. For example,<br />

VAULT VLTLOC=B SLOTS=(100,200)<br />

VAULT VLTLOC=B SLOTS=(300,400)<br />

VAULT VLTLOC=B SLOTS=(500,600)<br />

VAULT VLTLOC=C SLOTS=(50,100)<br />

To place slot numbers within your <strong>CA</strong> <strong>Dynam</strong> Catalog, run the following as the<br />

first VAULT movement after the conversion:<br />

// JOB TDYNVLT<br />

// DLBL WORK1,'WORK.01'<br />

// EXTENT SYS001..........<br />

// ASSGN SYS001,cuu<br />

3–46 <strong>User</strong> <strong>Guide</strong>