Tape File Management Utilities<br />

SYSTEM NODEIDS DO NOT MATCH<br />

Indicates that the NODEIDs (under the column SYSTEM) do not reflect the<br />

same in<strong>for</strong>mation about the owning system. The conflict is resolved<br />

automatically by selecting the volume with the most recent creation date and<br />

time. If both volumes have the same date and time, the owning system is<br />

assumed to have the correct NODEID and will be used to update the other<br />

system.<br />

SYSn EXTRACT HAS BAD STATUS/OWNER<br />

Indicates that the volume or owner in<strong>for</strong>mation <strong>for</strong> the volume in question<br />

does not contain appropriate values. This may indicate a problem in the<br />

extract utility. If attempting to resolve this error, contact a <strong>CA</strong> Technical<br />

Support representative <strong>for</strong> the system indicated in the message.<br />

VOLSER NOT ON SYSn EXTRACT<br />

Indicates that the volume is active on one system and either not defined or<br />

out-of-service (DELETE status) on the other system. The system that does not<br />

have the volume defined is notified of the status of the volume on the owning<br />

system.<br />

VOLUME STATUS DOES NOT MATCH<br />

Indicates that the volumes are not in the same status on both systems. The<br />

conflict is resolved automatically by selecting the volume with the most recent<br />

creation date and time. If both volumes have the same date and time, the<br />

owning system is assumed to have the correct status, and will be used to<br />

update the other system.<br />

If processing cannot be per<strong>for</strong>med, the following messages appear:<br />

END-OF-FILE ON SYSTEMn EXTRACT, EXPECTED SYSTEM IDENTIFI<strong>CA</strong>TION<br />

RECORD<br />

The extract <strong>for</strong> the system specified does not contain any data. Verify that the<br />

data set is specified correctly and that it was created by the appropriate<br />

extract utility.<br />

END-OF-FILE ON SYSTEMn EXTRACT, EXPECTED VOLUME INFORMATION<br />

RECORDS<br />

The extract of the system specified does not contain any volume in<strong>for</strong>mation.<br />

Verify that the data set is specified correctly and that it was created by the<br />

appropriate extract utility. If attempting to resolve this error, contact a <strong>CA</strong><br />

Technical Support representative <strong>for</strong> the system indicated in the message.<br />