Tape File Management Utilities<br />

REMOVE<br />

Optional. Removes all catalog entries <strong>for</strong> a particular CPUID.<br />

Detailed descriptions of the commands follow, presented in alphabetical order.<br />

APPLY Command<br />

The APPLY command takes as input one of the two output files from the SYNC<br />

processing and updates the <strong>CA</strong> <strong>Dynam</strong> Catalog with tape volume status<br />

in<strong>for</strong>mation. When the <strong>CA</strong> <strong>Dynam</strong>/T TDYNSYNC APPLY commands <strong>for</strong> each <strong>CA</strong><br />

<strong>Dynam</strong> Catalog, and the equivalent commands <strong>for</strong> each participating database<br />

(such as DYNUPDTE <strong>for</strong> <strong>CA</strong> 1 MVS) are completed, the tape management<br />

systems will be synchronized with respect to tape volume status.<br />

Format:<br />

APPLY<br />

Examples:<br />

// JOB APPLY // JOB APPLY<br />

// DLBL <strong>CA</strong>T1IN,'DOS<strong>VSE</strong>.APPLY' - OR - // TLBL <strong>CA</strong>T1IN,'DOS<strong>VSE</strong>.APPLY'<br />

// EXTENT SYS004, // ASSGN SYS004,CUU<br />

// ASSGN SYS004,CUU // EXEC TDYNSYNC,SIZE=128K<br />

// EXEC TDYNSYNC,SIZE=128K APPLY<br />

APPLY /*<br />

/* /&<br />

/&<br />

Note:<br />

• TDYNSYNC output files can be created on disk or on tape.<br />

• The dtfname <strong>for</strong> the input file must be specified as <strong>CA</strong>T1IN, even if the file<br />

being used as input was created using dtfname <strong>CA</strong>T2OUT from the SYNC<br />

step.<br />

• TDYNSYNC can only APPLY data to the <strong>CA</strong> <strong>Dynam</strong> Catalog. To update<br />

volume status in<strong>for</strong>mation <strong>for</strong> the <strong>CA</strong> 1 TMC, use the <strong>CA</strong> 1 supplied<br />

DYNUPDTE utility.<br />

• The default dtfname of the catalog from which the volume status<br />

in<strong>for</strong>mation is to be extracted is <strong>CA</strong>I<strong>CA</strong>TL. If you are extracting data from<br />

another catalog, use the <strong>CA</strong>TNAME control statement to specify the<br />

dtfname of the catalog.<br />