<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

www.codanbroadcast.com


<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

Table of Contents<br />

<strong>NK</strong> <strong>Series</strong> System Overview 2<br />

Routers 5<br />

<strong>NK</strong>-MD SD/HD Multi-Definition Video Router Level 6<br />

<strong>NK</strong>-S SDI Video Router Level 8<br />

<strong>NK</strong>-V Analogue Video Router Level 10<br />

<strong>NK</strong>-D AES/EBU Digital Audio Router Level (75 Ω) 12<br />

<strong>NK</strong>-D AES/EBU Digital Audio Router Level (110 Ω) 14<br />

<strong>NK</strong>-A Stereo Analog Audio Router Level 16<br />

<strong>NK</strong>-M Machine Control/Data Router Level 18<br />

Kondor 2 Large Scale Router Levels 19<br />

Remote Control Panels 21<br />

<strong>NK</strong> <strong>Series</strong> Remote Control Panel Overview 22<br />

Remote Control Panel Selection Guide 23<br />

RCP-<strong>NK</strong>Q Remote Control Panel 24<br />

RCP-<strong>NK</strong>M Remote Control Panel 25<br />

RCP-<strong>NK</strong>1 Remote Control Panel 26<br />

Control Interface 27<br />

<strong>NK</strong>-IPS Network Bridge 28<br />

<strong>NK</strong>-VRC Virtual <strong>Routing</strong> Core 30<br />

<strong>NK</strong>-JBX Geneos RCP Interface 32<br />

<strong>NK</strong>-SCP/A ASCII/RS-232 Control Interface 34<br />

<strong>NK</strong>-SCP/K2 RS-485 Control Interface 35<br />

<strong>NK</strong>-GPI General Purpose Interface 36<br />

<strong>NK</strong>-RP1 Redundant Power Supply 37<br />

Phoenix Control Surface 39<br />

A Single Point Solution 40<br />

Locating Devices 41<br />

Intuitive Configuration 42<br />

Advanced Control 43<br />

Advanced Features 44<br />

Automatic Software Updates 45<br />

Ordering Information 46<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

2


<strong>NK</strong> <strong>Series</strong> System Overview<br />

Key Features<br />

►►<br />

Distributed architecture, no single<br />

point of failure<br />

►►<br />

All signal types supported<br />

►►<br />

Up to 32 independent routing levels<br />

►►<br />

Intuitive extendable GUI—Phoenix<br />

Control Surface<br />

►►<br />

Up to 2 000 data labels using <strong>NK</strong>-VRC<br />

►►<br />

16 x 4/16 x 16 in 1 RU, 64 mm depth<br />

►►<br />

32 x 32/34 x 34 in 2 RU, 64 mm depth<br />

►►<br />

64 x 64/72 x 72 in 3 RU, 120 mm<br />

depth<br />

►►<br />

Configure using Phoenix or web<br />

browser using the <strong>NK</strong>-IPS network<br />

bridge<br />

►►<br />

Low jitter for digital routers<br />

►►<br />

Various configuration and control<br />

options including remote control<br />

panels, web browsers and Phoenix<br />

Control Surface<br />

►►<br />

Expandable to 256 x 256 (SDI and<br />

HDTV) and 128 x 128 (AES/EBU,<br />

Analogue Audio and Analogue Video)<br />

using Kondor 2 router levels<br />

Family Overview<br />

Family Overview<br />

Codan Broadcast’s <strong>NK</strong> <strong>Series</strong> of routers offers a low cost,<br />

low risk transition path from simple routers to sophisticated<br />

Codan Broadcast’s <strong>NK</strong> <strong>Series</strong> of routers offers a low cost,<br />

routing systems.<br />

low risk transition path from simple routers to sophisticated<br />

The routing <strong>NK</strong> systems. <strong>Series</strong> is a family of routing products that caters for<br />

both basic and sophisticated applications. The <strong>NK</strong> <strong>Series</strong><br />

The <strong>NK</strong> <strong>Series</strong> is a family of routing products that caters for<br />

supports video (SD/HD, SD and analogue), audio (AES/EBU<br />

both basic and sophisticated applications. The <strong>NK</strong> <strong>Series</strong><br />

and analogue) and machine control (reciprocal RS-422).<br />

supports video (SD/HD, SD and analogue), audio (AES/EBU<br />

Additional and analogue) system and components machine control include (reciprocal the Phoenix RS-422). Control<br />

Surface, a broad range of fully programmable control panels,<br />

Additional system components include the Phoenix Control<br />

Surface, a broad range of fully programmable control panels,<br />

<strong>NK</strong> <strong>Series</strong> Router Levels<br />

1RU 2RU 3RU<br />

Levels 16 x 4 16 x 16 32 x 32 34 x 34 64 x 64 72 x 72<br />

MD (SD and HD) <strong>NK</strong>-MD164 <strong>NK</strong>-MD16 <strong>NK</strong>-MD34 <strong>NK</strong>-MD72*<br />

SD SDI <strong>NK</strong>-S164 <strong>NK</strong>-S16 <strong>NK</strong>-S34 <strong>NK</strong>-S72*<br />

Analogue Video <strong>NK</strong>-V164 <strong>NK</strong>-V16 <strong>NK</strong>-V32<br />

AES/EBU (75 Ω / 110 Ω) <strong>NK</strong>-D164 <strong>NK</strong>-D16 <strong>NK</strong>-D32 <strong>NK</strong>-D64*<br />

Stereo Analogue Audio <strong>NK</strong>-A164 <strong>NK</strong>-A16 <strong>NK</strong>-A32 <strong>NK</strong>-A64*<br />

Data (RS-422 Machine Control) <strong>NK</strong>-M16 <strong>NK</strong>-M32<br />

a virtual routing core, a network bridge, a GPI interface,<br />

automation interfaces and other protocol converters, plus<br />

a virtual routing core, a network bridge, a GPI interface,<br />

rack-mount redundant power supplies.<br />

automation interfaces and other protocol converters, plus<br />

Kondor rack-mount 2 router redundant frames power further supplies. expand system size and<br />

enhance functionality with no change in the control system.<br />

Kondor 2 router frames further expand system size and<br />

An enhance <strong>NK</strong> router functionality system, with whether no change consisting in the control of one system. level or<br />

many, is simple to configure and operate.<br />

An <strong>NK</strong> router system, whether consisting of one level or<br />

many, is simple to configure and operate.<br />

*Expandable from 8x8 in groups of 8<br />

3 Codan Broadcast


Configuration and Operation<br />

Configuration for all <strong>NK</strong> devices is via the Phoenix Control<br />

Surface or a web browser. Each router level may be divided<br />

into smaller partitions that may be assigned to a unique or<br />

common switching level.<br />

Operation is via any <strong>NK</strong> <strong>Series</strong> remote control panel,<br />

the Phoenix Control Surface or <strong>NK</strong>-VCP virtual control<br />

panel. Every key of each <strong>NK</strong> <strong>Series</strong> remote control panel<br />

is configurable to enable panels to be customised for the<br />

project or the operator.<br />

Phoenix is a simple-to-use, highly visual GUI. With Phoenix,<br />

the full capabilities of the <strong>NK</strong> system are available from your<br />

PC, including configuration of all router levels and remote<br />

control panels, monitoring and system control.<br />

The <strong>NK</strong>-VCP virtual control panel enables users to remotely<br />

control an entire <strong>NK</strong> system, making crosspoints as easy as<br />

a mouse click!<br />

Kondor 2 Router Levels<br />

1 x 6 RU Frame 2 x 6 RU Frame 4 x 6 RU Frame<br />

Levels 48 x 48 64 x 64 96 x 96 128 x 128 64 x 64 96 x 96 128 x 128 144 x 144 128 x 128 160 x 160 192 x 192 256 x 256<br />

MD (SD and HD) K2-MD144 K2-MD256<br />

SD SDI K2-S144 K2-S256<br />

Analogue Video K2-V64 K2-V128<br />

AES/EBU (75Ω / 110Ω)<br />

K2-D128<br />

Mono Analogue Audio<br />

K2-A128-M<br />

Stereo Analogue Audio<br />

K2-A128<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

4


Product Range<br />

►►<br />

SD/HD Multi-Definition Router Level (<strong>NK</strong>-MD)<br />

►►<br />

SD/SDI Digital Video Router Level (<strong>NK</strong>-S)<br />

►►<br />

Analogue Video Router Level (<strong>NK</strong>-V)<br />

►►<br />

AES/EBU Digital Audio Router Level (<strong>NK</strong>-D)<br />

►►<br />

Stereo Analogue Audio Router Level (<strong>NK</strong>-A)<br />

►►<br />

Machine Control/Data Router Level (<strong>NK</strong>-M)<br />

►►<br />

Kondor 2 Router Levels (K2)<br />

►►<br />

Selection of fully programmable Remote<br />

Control Panels (RCP-<strong>NK</strong>Q, RCP-<strong>NK</strong>M and<br />

RCP-<strong>NK</strong>1, plus Geneos Control Panels via<br />

<strong>NK</strong>-JBX)<br />

►►<br />

Network Bridge(<strong>NK</strong>-IPS)<br />

►►<br />

Virtual <strong>Routing</strong> Core (<strong>NK</strong>-VRC)<br />

►►<br />

Serial Control Port—ASCII/RS-232 Interface<br />

(<strong>NK</strong>-SCP/A)<br />

►►<br />

Serial Control Port—RS-485 Interface<br />

(<strong>NK</strong>-SCP/K2)<br />

►►<br />

General Purpose Interface (<strong>NK</strong>-GPI)<br />

►►<br />

Redundant Power Supply (<strong>NK</strong>-RP1)<br />

►►<br />

Phoenix Control Surface (<strong>NK</strong>-PCS)<br />

The T-Bus Control System<br />

The <strong>NK</strong>-IPS Network Bridge is connected to other <strong>NK</strong> <strong>Series</strong><br />

devices via the Codan Broadcast T-Bus control system,<br />

a multi-drop RS-485 control system supporting collision<br />

detection and half-duplex communication. The T-Bus control<br />

system minimises cable connections between devices, acting<br />

as both the communications line and a reliable means to<br />

phantom power <strong>NK</strong> <strong>Series</strong> devices, such as the RCP-<strong>NK</strong>1, the<br />

<strong>NK</strong>-SCP/A and the <strong>NK</strong>-GPI.<br />

The T-Bus control system’s collision detection support ensures<br />

that if two devices transmit messages at the same time they<br />

will not send incorrect data to other devices on the line. All<br />

components that utilise the T-Bus Control System are able<br />

to monitor communication on the line to ensure that no<br />

two devices are transmitting at the same time, maximising<br />

reliability and minimising the risk of communication errors.<br />

Router Flexibility<br />

The <strong>NK</strong> <strong>Series</strong> of routers may be configured with multiple<br />

partitions, effectively making two or more smaller routers from<br />

the one frame. Partitioning enables a flexible routing solution<br />

for applications where multiple switches must be activated<br />

on the one level. Partitions configured on the analogue<br />

video level enables users to configure single routers to switch<br />

independent YUV or RGB signals simultaneously. For the<br />

analogue and digital audio levels, users can partition routers<br />

to switch simultaneously when using multiple language<br />

streams.<br />

Sources<br />

32 24 16 8 1<br />

Sources<br />

32 24 16 8 1<br />

1 8 16 24 32<br />

Destinations<br />

1 8 16 24 32<br />

Destinations<br />

Legend<br />

Unused Crosspoints<br />

Sources<br />

32 24 16 8 1<br />

Sources<br />

32 24 16 8 1<br />

Router Partitioning<br />

1 8 16 24 32<br />

Destinations<br />

1 8 16 24 32<br />

Destinations<br />

The example above shows crosspoint assignments<br />

when a 32 x 32 router is partitioned. The image<br />

displays a 32 x 32 router with no partitions (top<br />

left); a 32 x 32 router partitioned as two 16 x 16<br />

routers (top right); a 32 x 32 router partitioned<br />

as three 10 x 10 routers (bottom left); and a<br />

32 x 32 router partitioned as four 8 x 8 routers<br />

(bottom right).<br />

5 Codan Broadcast


Routers


<strong>NK</strong>-MD<br />

SD/HD Multi-Definition Video Router Level<br />

Key Features<br />

►►<br />

Compact size<br />

►►<br />

Data rates 143 Mb/s to 1.485 Gb/s<br />

►►<br />

Cable equalising inputs<br />

►►<br />

Non-reclocking outputs<br />

►►<br />

<strong>NK</strong>-MD72 modular — expandable<br />

from 8 x 8 in groups of 8<br />

►►<br />

Supports SMPTE standards 259M,<br />

292M and 344M<br />

►►<br />

Excellent performance and<br />

specifications<br />

►►<br />

Low power consumption<br />

►►<br />

Fully integrated with other <strong>NK</strong> <strong>Series</strong><br />

devices<br />

<strong>NK</strong>-MD164<br />

<strong>NK</strong>-MD16<br />

<strong>NK</strong>-MD34<br />

Ordering Information<br />

<strong>NK</strong>-MD164 16 x 4 SD/HD Video Router<br />

<strong>NK</strong>-MD16 16 x 16 SD/HD Video Router<br />

<strong>NK</strong>-MD34 34 x 34 SD/HD Video Router<br />

<strong>NK</strong>-MD72 72 x 72 SD/HD Video Router<br />

<strong>NK</strong>-MD-FRM 72 x 72 SD/HD Video Router Frame<br />

<strong>NK</strong>-IMD SD/HD Input Card (8 channel)<br />

<strong>NK</strong>-OMD SD SD/HD Output Card (8 channel)<br />

<strong>NK</strong>-ISD SD Input Card (8 channel)<br />

<strong>NK</strong>-OSD SD Output Card (8 channel)<br />

<strong>NK</strong>-MD72<br />

7 Codan Broadcast


Overview<br />

<strong>NK</strong>-MD router levels are available in three sizes:<br />

►►<br />

1 RU 16 x 4 and 16 x 16 (fixed capacity)<br />

►►<br />

2 RU 34 x 34 (fixed capacity)<br />

►►<br />

3 RU 72 x 72 (expandable from 8 x 8 in groups of 8)<br />

The operational capacity of the <strong>NK</strong>-MD72 router level is determined by the number of<br />

input and output cards inserted. The <strong>NK</strong>-MD72 can accept SD only or SD/HD multidefinition<br />

I/O cards. Adding new I/O cards is a simple operation taking just a few minutes.<br />

Ask your Codan Broadcast representative for more details.<br />

The <strong>NK</strong>-MD router levels are designed from the ground up to handle high-bandwidth,<br />

broadcast-quality, digital video signals.<br />

The multi-definition router level of the <strong>NK</strong> family is capable of handling SD and HD signal<br />

streams, as well as DVB-ASI and SDTI streams, supporting SMPTE standards 259M, 292M<br />

and 344M.<br />

<strong>NK</strong>-MD router levels may be divided into smaller partitions, which may be assigned to a<br />

unique or common switching level.<br />

Technical Specifications<br />

<strong>NK</strong>-MD164 <strong>NK</strong>-MD16 <strong>NK</strong>-MD34 <strong>NK</strong>-MD72<br />

INPUTS<br />

Connection<br />

75 Ω BNC<br />

Total # of Inputs 16 16 34 72 (max.)<br />

Return Loss<br />

>17 dB<br />

Level<br />

800 mV p–p<br />

Cable EQ Up to 100 m Belden 8281<br />

OUTPUTS<br />

Connection<br />

75 Ω BNC<br />

Total # of Outputs 4 16 34 72 (max.)<br />

Clocking<br />

Non-reclocking<br />

Level<br />

800 mV p–p<br />

Return Loss<br />

15 dB<br />

PERFORMANCE<br />

Jitter<br />


<strong>NK</strong>-S<br />

SDI Video Router Level<br />

Key Features<br />

►►<br />

Compact size<br />

►►<br />

Data rates 143 to 540 Mb/s<br />

►►<br />

Cable equalising inputs<br />

►►<br />

Non-reclocking outputs<br />

►►<br />

<strong>NK</strong>-S72 modular — expandable from<br />

8 x 8 in groups of 8<br />

►►<br />

Supports SMPTE standard 259M<br />

►►<br />

Excellent performance and<br />

specifications<br />

►►<br />

Low power consumption<br />

►►<br />

Fully integrated with other <strong>NK</strong> <strong>Series</strong><br />

devices<br />

<strong>NK</strong>-S164<br />

<strong>NK</strong>-S16<br />

<strong>NK</strong>-S34<br />

Ordering Information<br />

<strong>NK</strong>-S164 16 x 4 SDI Video Router<br />

<strong>NK</strong>-S16 16 x 16 SDI Video Router<br />

<strong>NK</strong>-S34 34 x 34 SDI Video Router<br />

<strong>NK</strong>-S72 72 x 72 SDI Video Router<br />

<strong>NK</strong>-MD-FRM 72 x 72 SD/HD Video Router Frame<br />

<strong>NK</strong>-ISD SD Input Card (8 channel)<br />

<strong>NK</strong>-OSD SD Output Card (8 channel)<br />

<strong>NK</strong>-S72<br />

9 Codan Broadcast


Overview<br />

<strong>NK</strong>-S router levels are available in three sizes:<br />

►►<br />

1 RU 16 x 4 and 16 x 16 (fixed capacity)<br />

►►<br />

2 RU 34 x 34 (fixed capacity)<br />

►►<br />

3 RU 72 x 72 (expandable from 8 x 8 in groups of 8)<br />

The operational capacity of the <strong>NK</strong>-S72 is determined by the number of input and output<br />

cards inserted. Adding new I/O cards is a simple operation taking just a few minutes.<br />

The <strong>NK</strong>-S72 core can be upgraded to be SD/HD capable. Ask your Codan Broadcast<br />

representative for more details.<br />

The <strong>NK</strong>-S router levels are designed from the ground up to handle high-bandwidth,<br />

broadcast-quality, digital video signals.<br />

The SD router level of the <strong>NK</strong> family is capable of handling SD signal streams, as well as<br />

DVB-ASI and SDTI streams.<br />

<strong>NK</strong>-S router levels may be divided into smaller partitions, which may be assigned to a<br />

unique or common switching level.<br />

Technical Specifications<br />

<strong>NK</strong>-S164 <strong>NK</strong>-S16 <strong>NK</strong>-S34 <strong>NK</strong>-S72<br />

INPUTS<br />

Connection<br />

75 Ω BNC<br />

Total # of Inputs 16 16 34 72 (max.)<br />

Return Loss<br />

>22 dB<br />

Level<br />

800 mV p–p<br />

Cable EQ Up to 350 m Belden 8281<br />

OUTPUTS<br />

Connection<br />

75 Ω BNC<br />

Total # of Outputs 4 16 34 72 (max.)<br />

Clocking<br />

Non-reclocking<br />

Level<br />

800 mV p–p<br />

Return Loss<br />

15 dB<br />

PERFORMANCE<br />

Jitter<br />


<strong>NK</strong>-V<br />

Analogue Video Router Level<br />

Key Features<br />

►►<br />

Compact size<br />

►►<br />

Excellent frequency response<br />

characteristics<br />

►►<br />

Input return loss 44 dB<br />

►►<br />

Output return loss 30 dB<br />

►►<br />

Excellent performance and<br />

specifications<br />

►►<br />

Low power consumption<br />

►►<br />

Fully integrated with other <strong>NK</strong> <strong>Series</strong><br />

devices<br />

<strong>NK</strong>-V164<br />

<strong>NK</strong>-V16<br />

Ordering Information<br />

<strong>NK</strong>-V164 16 x 4 Analogue Video Router<br />

<strong>NK</strong>-V16 16 x 16 Analogue Video Router<br />

<strong>NK</strong>-V32 32 x 32 Analogue Video Router<br />

<strong>NK</strong>-V32<br />

11 Codan Broadcast


Overview<br />

<strong>NK</strong>-V router levels are available in two sizes:<br />

►►<br />

1 RU 16 x 4 and 16 x 16<br />

►►<br />

2 RU 32 x 32<br />

The <strong>NK</strong>-V router levels are designed from the ground up with high-bandwidth and highperformance<br />

specifications, normally only found in large scale routers, and are capable<br />

of handling broadcast-quality analogue video signals.<br />

<strong>NK</strong>-V router levels may be divided into smaller partitions, which may be assigned to a<br />

unique or common switching level.<br />

<strong>NK</strong> <strong>Series</strong> analogue video routers may be configured to switch individual RGB or YUV<br />

channels simultaneously when the router is configured into multiple smaller partitions.<br />

The <strong>NK</strong>-V16 router may be configured as three 5 x 5 routers, and the <strong>NK</strong>-V32 may be<br />

configured as three 10 x 10 routers. For RGB or YUV router sizes larger than 10 x 10,<br />

multiple <strong>NK</strong>-V16 or <strong>NK</strong>-V32 routers may be used to switch RGB or YUV channels in<br />

specific user applications. Ask your Codan Broadcast representative for more details.<br />

Technical Specifications<br />

INPUTS<br />

Connection<br />

<strong>NK</strong>-V164 <strong>NK</strong>-V16 <strong>NK</strong>-V32<br />

75 Ω BNC<br />

Total # of Inputs 16 16 32<br />

Nominal Input Level<br />

Maximum Input Level<br />

Clamping Method<br />

Clamping DC Adjustment<br />

Return Loss<br />

OUTPUTS<br />

Connection<br />

1 V p–p<br />

2 V p–p<br />

AC coupled with sync-tip clamping<br />

Between blanking = 0 V and sync-tip = 0 V<br />

44 dB<br />

75 Ω BNC<br />

Total # of Outputs 4 16 32<br />

Level<br />

Coupling<br />

1 V p–p<br />

DC coupled<br />

Return Loss<br />

30 dB<br />

PERFORMANCE<br />

Differential Gain 0.05%<br />

Differential Phase 0.05°<br />

Frequency Response 30 MHz, ±0.1 dB<br />

60 MHz, ±1 dB<br />

230 MHz, −3 dB<br />

Noise<br />

−76 dB peak<br />

Crosstalk<br />

−60 dB, 5 MHz<br />

Transmit Time<br />

2 ns<br />

Timing Scatter<br />

0.5° Fsc<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

GENERAL<br />

Partitioning<br />

Up to 8 partitions with independent level assignment<br />

Configuration<br />

Web browser via <strong>NK</strong>-IPS<br />

Phoenix Control Surface via <strong>NK</strong>-IPS<br />

Dimensions 1 RU x 64 mm 1 RU x 64 mm 2 RU x 64 mm<br />

Power Consumption 12 W 12 W 26 W<br />

Power Supply<br />

±15 V DC<br />

Specifications subject to change without prior notice.<br />

12


<strong>NK</strong>-D<br />

AES/EBU Digital Audio Router Level (75 Ω)<br />

Key Features<br />

►►<br />

Compact size<br />

►►<br />

Data rates 32 to 192 kHz<br />

►►<br />

Available in 75 Ω unbalanced and<br />

110 Ω balanced versions<br />

►►<br />

<strong>NK</strong>-D64 modular — expandable from<br />

8 x 8 in groups of 8<br />

►►<br />

Excellent performance and<br />

specifications<br />

►►<br />

Low power consumption<br />

►►<br />

Fully integrated with other <strong>NK</strong> <strong>Series</strong><br />

devices<br />

<strong>NK</strong>-D164/75<br />

<strong>NK</strong>-D16/75<br />

<strong>NK</strong>-D32/75<br />

Ordering Information<br />

<strong>NK</strong>-D164/75 16 x 4 AES/EBU Digital Audio<br />

Router (75 Ω)<br />

<strong>NK</strong>-D16/75 16 x 16 AES/EBU Digital Audio<br />

Router (75 Ω)<br />

<strong>NK</strong>-D32/75 32 x 32 AES/EBU Digital Audio<br />

Router (75 Ω))<br />

<strong>NK</strong>-D64/75 64 x 64 AES/EBU Digital Audio<br />

Router (75 Ω)<br />

<strong>NK</strong>-D-FRM-75 64 x 64 AES/EBU Compact Router<br />

Frame<br />

<strong>NK</strong>-IDE-75 AES/EBU Input Card (8 channel)<br />

<strong>NK</strong>-ODE-75 AES/EBU Output Card (8 channel)<br />

<strong>NK</strong>-D64/75<br />

13 Codan Broadcast


Overview<br />

<strong>NK</strong>-D router levels are available in three sizes:<br />

►►<br />

1 RU 16 x 4 or 16 x 16 (fixed capacity)<br />

►►<br />

2 RU 32 x 32 (fixed capacity)<br />

►►<br />

3 RU 64 x 64 (expandable from 8 x 8 in groups of 8)<br />

The <strong>NK</strong>-D AES/EBU router level of the <strong>NK</strong> family is capable of handling AES/EBU signal<br />

streams, as well as other compressed digital audio streams that are within the router’s<br />

clocking rate.<br />

The operational capacity of the <strong>NK</strong>-D64 is determined by the number of input and output<br />

cards inserted. Adding new I/O cards is a simple operation taking just a few minutes.<br />

The <strong>NK</strong>-D router levels are designed from the ground up to handle high-bandwidth,<br />

broadcast-quality, digital audio signals.<br />

<strong>NK</strong>-D router levels may be divided into smaller partitions, which may be assigned to a<br />

unique or common switching level.<br />

Technical Specifications<br />

<strong>NK</strong>-D164/75 <strong>NK</strong>-D16/75 <strong>NK</strong>-D32/75 <strong>NK</strong>-D64/75<br />

INPUTS<br />

Connection<br />

75 Ω unbalanced BNC<br />

Total # of Inputs 16 16 32 64 (max.)<br />

Level<br />

1 V p–p<br />

Cable EQ<br />

Up to 300 m RG59/U<br />

OUTPUTS<br />

Connection<br />

75 Ω unbalanced BNC<br />

Total # of Outputs 4 16 32 64 (max.)<br />

Clocking<br />

Non-reclocking<br />

Level<br />

1 V p–p<br />

PERFORMANCE<br />

Jitter<br />


<strong>NK</strong>-D<br />

AES/EBU Digital Audio Router Level (110 Ω)<br />

Key Features<br />

►►<br />

Compact size<br />

►►<br />

Data rates 32 to 192 kHz<br />

►►<br />

Available in 75 Ω unbalanced and<br />

110 Ω balanced versions<br />

►►<br />

<strong>NK</strong>-D64 modular — expandable from<br />

8 x 8 in groups of 8<br />

►►<br />

Excellent performance and<br />

specifications<br />

►►<br />

Low power consumption<br />

►►<br />

Fully integrated with other <strong>NK</strong> <strong>Series</strong> devices<br />

devices<br />

<strong>NK</strong>-D164/110<br />

<strong>NK</strong>-D16/110<br />

<strong>NK</strong>-D32/110<br />

Ordering Information<br />

<strong>NK</strong>-D164/110 16 x 4 AES/EBU Audio Router (110 Ω)<br />

<strong>NK</strong>-D16/110 16 x 16 AES/EBU Audio Router (110 Ω)<br />

<strong>NK</strong>-D32/110 32 x 32 AES/EBU Audio Router (110 Ω)<br />

<strong>NK</strong>-D64/110 64 x 64 AES/EBU Audio Router (110 Ω)<br />

<strong>NK</strong>-D-FRM-110 64 x 64 AES/EBU Compact Router Frame<br />

<strong>NK</strong>-IDE-110 AES/EBU Input Card (8 channel)<br />

<strong>NK</strong>-ODE-110 AES/EBU Output Card (8 channel)<br />

<strong>NK</strong>-D64/110<br />

15 Codan Broadcast


Overview<br />

<strong>NK</strong>-D router levels are available in three sizes:<br />

►►<br />

1 RU 16 x 4 or 16 x 16 (fixed capacity)<br />

►►<br />

2 RU 32 x 32 (fixed capacity)<br />

►►<br />

3 RU 64 x 64 (expandable from 8 x 8 in groups of 8)<br />

The <strong>NK</strong>-D AES/EBU router level of the <strong>NK</strong> family is capable of handling AES/EBU signal<br />

streams, as well as other compressed digital audio streams that are within the router’s<br />

clocking rate.<br />

The operational capacity of the <strong>NK</strong>-D64 is determined by the number of input and output<br />

cards inserted. Adding new I/O cards is a simple operation taking just a few minutes.<br />

The <strong>NK</strong>-D router levels are designed from the ground up to handle high-bandwidth,<br />

broadcast-quality, digital audio signals.<br />

<strong>NK</strong>-D router levels may be divided into smaller partitions, which may be assigned to a<br />

unique or common switching level.<br />

Technical Specifications<br />

<strong>NK</strong>-D164/110 <strong>NK</strong>-D16/110 <strong>NK</strong>-D32/110 <strong>NK</strong>-D64/110<br />

INPUTS<br />

Connection<br />

110 Ω balanced DB-25 connectors<br />

Total # of Inputs 16 16 32 64 (max.)<br />

Level<br />

1 – 7 V p–p<br />

Cable EQ<br />

Up to 100 m Belden B1800B<br />

OUTPUTS<br />

Connection<br />

110 Ω balanced DB-25 connectors<br />

Total # of Outputs 4 16 32 64 (max.)<br />

Clocking<br />

Non-reclocking<br />

Level<br />

2 – 4 V p–p<br />

PERFORMANCE<br />

Jitter<br />

Data Rates<br />

GENERAL<br />

Partitioning<br />

Configuration<br />


<strong>NK</strong>-A<br />

Stereo Analogue Audio Router Level<br />

Key Features<br />

►►<br />

Compact size<br />

►►<br />

Balanced inputs (can be wired as<br />

unbalanced)<br />

►►<br />

Excellent frequency response<br />

characteristics<br />

►►<br />

Common mode rejection ratio 60 dB<br />

►►<br />

Output impedance 50 Ω<br />

►►<br />

<strong>NK</strong>-A64 modular — expandable from<br />

8x8 in groups of 8<br />

►►<br />

Excellent performance and<br />

specifications<br />

►►<br />

Low power consumption<br />

►►<br />

Fully integrated with other <strong>NK</strong> <strong>Series</strong> devices<br />

devices<br />

<strong>NK</strong>-A164<br />

<strong>NK</strong>-A16<br />

<strong>NK</strong>-A32<br />

Ordering Information<br />

<strong>NK</strong>-A164<br />

<strong>NK</strong>-A16<br />

<strong>NK</strong>-A32<br />

<strong>NK</strong>-A64<br />

<strong>NK</strong>-A-FRM<br />

<strong>NK</strong>-IA<br />

<strong>NK</strong>-OA<br />

16 x 4 Stereo An. Audio Router<br />

16 x 16 Stereo An. Audio Router<br />

32 x 32 Stereo An. Audio Router<br />

64 x 64 Stereo An. Audio Router<br />

64 x 64 Stereo An. Audio Router Frame<br />

Stereo An. Audio Input Card (8 channel)<br />

Stereo An. Audio Output Card<br />

(8 channel)<br />

<strong>NK</strong>-A64<br />

17 Codan Broadcast


Overview<br />

<strong>NK</strong>-A router levels are available in three sizes:<br />

►►<br />

1 RU 16 x 4 and 16 x 16 (fixed capacity)<br />

►►<br />

2 RU 32 x 32 (fixed capacity)<br />

►►<br />

3 RU 64 x 64 (expandable from 8 x 8 in groups of 8)<br />

The <strong>NK</strong>-A router levels are designed from the ground up with high-bandwidth and highperformance<br />

specifications, normally only found in large scale routers, and are capable<br />

of handling broadcast-quality, analogue audio signals.<br />

<strong>NK</strong>-A router levels may be divided into smaller partitions, which may be assigned to a<br />

unique or common switching level.<br />

The operational capacity of the <strong>NK</strong>-A64 is determined by the number of input and output<br />

cards inserted. Adding new I/O cards is a simple operation taking just a few minutes.<br />

The <strong>NK</strong>-A analogue audio level of <strong>NK</strong>-A64 routers offers unparalleled configuration<br />

and audio processing, enabling users to mix left and right audio channels to suit their<br />

broadcast requirements. Channels may be swapped, phase inverted or converted to mono<br />

(both channels left, both channels right, both channels average, sum and difference).<br />

Technical Specifications<br />

<strong>NK</strong>-A164 <strong>NK</strong>-A16 <strong>NK</strong>-A32 <strong>NK</strong>-A64<br />

INPUTS<br />

Connection<br />

Balanced active differential DB-25<br />

Total # of Inputs 16 16 34 64 (max.)<br />

Input Z<br />

24 kΩ<br />

Nominal Input Level +4 dBu or −10 dBu (selectable via solder links per input)<br />

Maximum Input Level +24 dBu<br />

CMRR<br />

60 dB<br />

OUTPUTS<br />

Connection<br />

Balanced active differential DB-25<br />

Total # of Outputs 4 16 34 64 (max.)<br />

Output Z<br />

50 Ω<br />

Nominal Input Level +4 dBu or −10 dBu (selectable via solder links per output)<br />

Maximum Input Level +24 dBu<br />

PERFORMANCE<br />

Frequency Response ±0.1 dB, 20 Hz to 20 kHz<br />

−3 dB, 100 kHz<br />

Distortion 0.005%<br />

Noise<br />

−90 dB below +4 dBu<br />

Crosstalk<br />

Below noise<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

GENERAL<br />

Number of Levels Dual independent matrix layers<br />

Control Level No Yes<br />

Partitioning<br />

Up to 8 partitions per layer with independent level assignment<br />

Configuration Web browser via <strong>NK</strong>-IPS<br />

Phoenix Control Surface via <strong>NK</strong>-IPS<br />

Dimensions 1 RU x 64 mm 1 RU x 64 mm 2 RU x 64 mm 3 RU x 120 mm<br />

Power Consumption 19 W 19 W 38 W 75 W<br />

Power Supply ±15 V DC +15 V<br />

Specifications subject to change without prior notice.<br />

18


<strong>NK</strong>-M<br />

Machine Control/Data Router Level<br />

Key Features<br />

►►<br />

Compact size<br />

►►<br />

True reciprocal switching<br />

►►<br />

Allows one master to multiple slaves<br />

►►<br />

Auto port direction switching<br />

►►<br />

Excellent performance and<br />

specifications<br />

►►<br />

Low power consumption<br />

►►<br />

Fully integrated with other <strong>NK</strong> <strong>Series</strong> devices<br />

devices<br />

Ordering Information<br />

<strong>NK</strong>-M16<br />

<strong>NK</strong>-M32<br />

16 Port Machine Control (RS-422)<br />

Router<br />

32 Port Machine Control (RS-422)<br />

Router<br />

<strong>NK</strong>-M16<br />

<strong>NK</strong>-M32<br />

Overview<br />

Technical Specifications<br />

<strong>NK</strong>-M router levels are available in two sizes:<br />

<strong>NK</strong>-M16<br />

<strong>NK</strong>-M32<br />

►►<br />

1 RU 16 port<br />

INPUTS<br />

Connection<br />

DB-9 female on chassis<br />

►►<br />

2 RU 32 port<br />

Electrical Standard<br />

RS-422<br />

The <strong>NK</strong>-M machine control level of the <strong>NK</strong> family is designed<br />

from the ground up to route RS-422 signals for reciprocal<br />

switches.<br />

Direction<br />

PERFORMANCE<br />

Data Rate<br />

Auto port direction switching<br />

Up to 115.2 kBd<br />

<strong>NK</strong>-M routers are available as either a 16 port version<br />

GENERAL<br />

(<strong>NK</strong>-M16) or 32 port version (<strong>NK</strong>-M32), both able to switch<br />

Configuration<br />

Web browser via <strong>NK</strong>-IPS<br />

data rates up to 115.2 kBd.<br />

Phoenix Control Surface via <strong>NK</strong>-IPS<br />

Dimensions 1 RU x 64 mm 2 RU x 64 mm<br />

Power Consumption 9 W 15 W<br />

Power Supply<br />

+15 V DC<br />

Specifications subject to change without prior notice.<br />

19 Codan Broadcast


Kondor 2<br />

Large Scale Router Levels<br />

Overview<br />

Codan Broadcast’s <strong>NK</strong> <strong>Series</strong> of routers extend to sizes up to<br />

256 x 256 through the use of Kondor 2 router levels.<br />

The Kondor 2 provides a trusted and proven routing<br />

switcher capability in its own right. Many hundreds of<br />

Kondor 2 systems have been used worldwide in outside<br />

broadcast vans, production, post-production and studio<br />

environments, encompassing the most sophisticated and<br />

demanding applications. The Kondor 2 is engineered with<br />

no active components fixed inside the frame. The flexibility<br />

of the Kondor 2 is the uniquely engineered architecture of<br />

the 8-channel and 16-channel I/O cards and the innovative<br />

free-form backplane.<br />

The Kondor 2 offers users the ability to mix and match video,<br />

SDI, HDTV (SD/HD multi-definition), audio and AES/EBU<br />

signals —all in the same high-density rack frame.<br />

A 5 RU frame houses 25 modules. Multiple frames may be<br />

joined together for large configurations. Each frame slot can<br />

house input or output cards, a matrix switching core or a<br />

power supply, giving maximum flexibility to customers.<br />

All devices in a Kondor 2 frame (I/O cards, matrix switching<br />

cores and power supplies) are hot swappable without taking<br />

the router off-line and without removing any signal cable.<br />

In addition, users can move from SDI to HDTV eight inputs/<br />

outputs at a time—all at nominal cost.<br />

Key Features<br />

►►<br />

Every module hot swappable<br />

►►<br />

Fully expandable<br />

►►<br />

Mix and match video, SDI, HDTV, audio<br />

and AES/EBU in the same frame<br />

►►<br />

Supports SMPTE standards 259M,<br />

292M and 344M<br />

►►<br />

Performance remains constant with<br />

size<br />

►►<br />

Status LEDs for alarms<br />

►►<br />

Very efficient 1000 W power supplies<br />

►►<br />

Redundancy options for power supplies<br />

and matrix switching cores<br />

►►<br />

Signal presence indicators for each<br />

input and output<br />

►►<br />

Universal 5 RU frame<br />

►►<br />

Short signal path<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

20


A 1 RU fan system with front removable fan tray is located on top or bottom depending<br />

on cooling needs. The fan trays slide out for service and replacement while the system is<br />

operational. Three high efficiency fans draw air in through the filtered front door, through<br />

the power supplies, up through the cards, and exhaust via the back and sides. Other<br />

cooling options are available for systems made up with multiple frames.<br />

With the Kondor 2 router levels, the <strong>NK</strong> <strong>Series</strong> of routers now provides capacity from<br />

the smallest applications through to the very large; all in a modular fashion. The full<br />

capabilities of the <strong>NK</strong> <strong>Series</strong> systems are available when using Kondor 2 router levels,<br />

including the Phoenix Control Surface, <strong>NK</strong>-IPS network bridge, <strong>NK</strong>-VRC virtual routing<br />

core and <strong>NK</strong>-GPI interface. Naturally, all <strong>NK</strong> <strong>Series</strong> remote control panels may be used as<br />

well as Geneos control panels via the <strong>NK</strong>-JBX interface.<br />

Phoenix Control<br />

Surface<br />

<strong>NK</strong>-IPS - Network Bridge<br />

RCP-<strong>NK</strong>M - Remote Control Panel<br />

<strong>NK</strong>-VRC - Virtual <strong>Routing</strong> Core<br />

Technical Specifications<br />

Available on request.<br />

Ordering Information<br />

K2-RFA-15<br />

Kondor 2 ‘15’ Rack Frame Kit<br />

K2-RFA-1551 Kondor 2 ‘1551’ Rack Frame Kit<br />

PSU-55PP<br />

PSU-55PP 1000 W Power Supply<br />

PSU-55PN<br />

PSU-55PN 500 W/500 W +/- Power Supply<br />

K2-144XH<br />

144 x 144 SD/HD (Multi-Definition) Matrix Board<br />

K2-IMD/OMD SD/HD (Multi-Definition) Input (EQ)/Output 8 Ch<br />

K2-ISE/OSN SDI Input (EQ)/Output 8 ch<br />

K2-64XV<br />

64 x 64 Analogue Video Matrix Board<br />

K2-IV/OV<br />

Analogue Video Input/Output 8 Ch<br />

K2-64XD<br />

64 x 64 AES Matrix Board<br />

K2-IDE/ODE AES Input/Output 16 ch<br />

K2-64XA<br />

64 x 64 x 1 Analogue Audio Matrix Board<br />

K2-IA/OA<br />

Analogue Audio Input/Output 16 ch<br />

<strong>NK</strong>-K2<br />

Kondor 2 Interface<br />

<strong>NK</strong>-K2<br />

Legend<br />

T-Bus<br />

Serial<br />

Ethernet<br />

<strong>NK</strong>-M32 - Router Level<br />

Kondor 2 - Router Levels<br />

21 Codan Broadcast


Remote Control Panels


<strong>NK</strong> <strong>Series</strong> Remote Control Panel Overview<br />

The <strong>NK</strong> <strong>Series</strong> offers users complete system control with its native selection of remote<br />

control panels. Simple system control may be achieved with the use of the RCP-<strong>NK</strong>1<br />

or RCP-<strong>NK</strong>M. The <strong>NK</strong> <strong>Series</strong> RCP-<strong>NK</strong>M and RCP-<strong>NK</strong>Q also offer users more advanced<br />

functions including multiple-page menus and panel displays.<br />

In addition to the native <strong>NK</strong> <strong>Series</strong> remote control panels, the <strong>NK</strong>-JBX gives users the ability<br />

to integrate Geneos control panels into an <strong>NK</strong> <strong>Series</strong> system, substantially increasing<br />

control options for users who own or wish to use Geneos control panels.<br />

All <strong>NK</strong> <strong>Series</strong> remote control panels feature panel link functionality, allowing panels to be<br />

joined to act as one larger panel.<br />

T-Bus (RS-485)<br />

Address<br />

21<br />

22<br />

<strong>NK</strong> <strong>Series</strong> Remote Control Panels<br />

14<br />

<strong>NK</strong> <strong>Series</strong> Router Levels<br />

Panel Link Function<br />

In the diagram above, the RCP-<strong>NK</strong>Q and RCP-<strong>NK</strong>M remote control<br />

panels are operating individually.<br />

In the diagram below, the RCP-<strong>NK</strong>Q and RCP-<strong>NK</strong>M have been linked,<br />

effectively operating as one 80-key remote control panel.<br />

The <strong>NK</strong>-VCP<br />

In addition to hardware remote control panels, users may also use software control<br />

panels including the <strong>NK</strong>-VCP virtual control panel available on the installation CD-ROM<br />

accompanying the <strong>NK</strong>-IPS, or the <strong>NK</strong> Switchboard (see page 43) from the Phoenix Control<br />

Surface.<br />

Please refer to the Remote Control Panel Selection Guide on the following page for an<br />

overview of remote control panel features.<br />

T-Bus (RS-485)<br />

Address<br />

21<br />

21<br />

<strong>NK</strong> <strong>Series</strong> Remote Control Panels<br />

14<br />

Panel Link<br />

Address<br />

3<br />

4<br />

<strong>NK</strong> <strong>Series</strong> Router Levels<br />

23 Codan Broadcast


Remote Control Panel Selection Guide<br />

<strong>NK</strong> <strong>Series</strong> Panels<br />

Rack<br />

Units<br />

RCP-<strong>NK</strong>1 1<br />

RCP-<strong>NK</strong>M 1<br />

RCP-<strong>NK</strong>Q 1<br />

Power<br />

Supply<br />

Phantom<br />

(via T-Bus)<br />

5 V @<br />

2A Power<br />

Supply<br />

5 V @<br />

2A Power<br />

Supply<br />

Comms.<br />

Connector<br />

Assignable<br />

Keys<br />

RJ-45 40 Backlit LED<br />

RJ-45 40 Backlit LED<br />

RJ-45 17<br />

Key Type Functionality Display<br />

Graphic LCD<br />

(32x16 pix.)<br />

Cutbus<br />

Mode<br />

XY<br />

Mode<br />

Levels I/O Labels<br />

Virtual<br />

<strong>Routing</strong> Macros Panel<br />

Linking<br />

Phoenix<br />

Custom<br />

Module<br />

Userprogrammable<br />

P P 8 255 P P P P<br />

Userprogrammable<br />

Userprogrammable<br />

Backlit LCD<br />

(16 x 2 char.) P P 32 2000 Up to<br />

4000 P P P P<br />

17 LCD<br />

buttons P P 32 2000 Up to<br />

4000 P P P P<br />

Automation<br />

<strong>NK</strong>-GPI<br />

<strong>NK</strong>-SCP/A<br />

Box<br />

Box<br />

Phantom<br />

(via T-Bus)<br />

Phantom<br />

(via T-Bus)<br />

DB-37<br />

16 GPI Ins<br />

Contact<br />

Closure<br />

Return/Latch 16 GPI Outs 8 255<br />

P P<br />

DB-9 RS-232 ASCII Protocol 8 255<br />

P<br />

Kameleon<br />

(RCP-K)*<br />

1<br />

Internal<br />

IEC<br />

DB-9 48 LED<br />

Userprogrammable<br />

LED<br />

(8 x 2 char.) P P 8 255 255 P<br />

<strong>NK</strong>-JBX Supported Panels<br />

RCP-251* 1<br />

RCP-SN 2<br />

RCP-SK1 2<br />

RCP-SK4 2<br />

Internal<br />

IEC<br />

Internal<br />

IEC<br />

Internal<br />

IEC<br />

Internal<br />

IEC<br />

DB-9<br />

DB-9<br />

20<br />

(+ 10 set<br />

function keys)<br />

12<br />

(+ 8 set<br />

function keys)<br />

LED<br />

LED function<br />

DB-9 84 LED<br />

DB-9 48 LED<br />

Dedicated<br />

function keys<br />

Userprogrammable<br />

Userprogrammable<br />

Userprogrammable<br />

LED<br />

(16 x 2 char.) P P 8 255 255 P<br />

12 keys +<br />

status info.<br />

(240 x 64 pix.)<br />

P P 8 255 255 P P<br />

4 LED displays<br />

(8 char.) P P 8 255 255 P<br />

12 LED<br />

displays<br />

(8 char.)<br />

P P 8 255 255 P<br />

Virtual Panels<br />

<strong>NK</strong>-VCP User-defined GUI 8 255 255<br />

P<br />

N/A<br />

<strong>NK</strong><br />

Switchboard<br />

(via Phoenix)<br />

User-defined Phoenix 32 1 000 1 000<br />

P P<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

*Please note that while still supported by the <strong>NK</strong>-JBX, manufacture of this panel has been discontinued.<br />

24


RCP-<strong>NK</strong>Q<br />

Remote Control Panel<br />

Key Features<br />

►►<br />

17 backlit graphic LCD keys<br />

►►<br />

Menu driven and single key<br />

configurations<br />

►►<br />

Fast and simple to change<br />

configurations<br />

►►<br />

8 backlight colours<br />

►►<br />

Individual 5 V, 2 A power supply<br />

►►<br />

Compact 1 RU design<br />

CPU Upgrade for RCP-KQ1<br />

A simple, user-upgradeable controller board<br />

(<strong>NK</strong>Q-CPU) is available for users who already<br />

own a Geneos Q Panel (RCP-KQ1), providing<br />

a cost-effective solution for migrating devices<br />

to an <strong>NK</strong> <strong>Series</strong> routing switcher system. Ask<br />

your Codan Broadcast representative for more<br />

details.<br />

Ordering Information<br />

RCP-<strong>NK</strong>Q<br />

<strong>NK</strong>Q-CPU<br />

Remote Control Panel<br />

Controller board for upgrading<br />

existing Geneos RCP-KQ1 panels<br />

Overview<br />

The RCP-<strong>NK</strong>Q remote control panel offers 17 coloured<br />

backlit graphic LCD keys with multiple menus, enabling users<br />

to instantly navigate through the system with few key presses.<br />

The press of a menu key in the main menu opens a submenu,<br />

which refreshes the panel keys with new functions and<br />

labels.<br />

Assignment of navigation keys enables quick access to menus.<br />

Custom key labels (up to 10 characters across 2 lines), icons<br />

and colours can also be defined by the user for instant<br />

recognition of any key function. The colours and functions<br />

of the keys are set up using the Phoenix Control Surface,<br />

then this configuration document is sent to the panel. This<br />

eliminates unauthorised or accidental reprogramming.<br />

The RCP-<strong>NK</strong>Q is ideal for use on Outside Broadcast vans<br />

or in production houses where configurations change<br />

regularly. It is equally as useful in studios where the unlimited<br />

configurations enable fast and simple customised setups of<br />

each panel.<br />

Technical Specifications<br />

PANEL<br />

Number of Keys<br />

Display<br />

CONNECTIONS<br />

T-Bus<br />

GENERAL<br />

Configuration<br />

17 x graphic LCD keys<br />

17 x LCD (32 x 16 pix.)<br />

2 x RJ-45 (female, looping)<br />

Web browser via <strong>NK</strong>-IPS<br />

Phoenix Control Surface via<br />

<strong>NK</strong>-IPS<br />

1 RU x 44 mm deep<br />

External power pack 5 V @ 2 A<br />

11 W max. inc. plug pack<br />

Dimensions<br />

Power Supply<br />

Power Consumption<br />

Specifications subject to change without prior notice.<br />

25 Codan Broadcast


RCP-<strong>NK</strong>M<br />

Remote Control Panel<br />

Overview<br />

Each of the 40 keys of the RCP-<strong>NK</strong>M remote control panel<br />

can be assigned from a range of switch functions in the<br />

Phoenix Control Surface. The back-lit 16 x 2 LCD provides<br />

a large source and destination status display. The fully<br />

illuminated keys also have removable clear polycarbonate<br />

caps to enable labelling. Backlighting enables the labels to<br />

be viewed in low-lit control rooms making the panel perfect<br />

for almost any application. The panel can be used with any<br />

size router as XY, cutbus or multi-cutbus. The panel may also<br />

control multiple router levels, either tied or as breakaways.<br />

The flexibility of the RCP-<strong>NK</strong>M means that even after major<br />

system changes, it can be fully reprogrammed without the<br />

limitations of fixed function panels. Each panel can be<br />

assigned to any portion of the router with an individual set of<br />

labels and panel layout.<br />

Technical Specifications<br />

PANEL<br />

Number of Keys<br />

Display<br />

CONNECTIONS<br />

T-Bus<br />

GENERAL<br />

Configuration<br />

40 x backlit LED<br />

16 x 2 character LCD<br />

2 x RJ-45 (female, looping)<br />

Web browser via <strong>NK</strong>-IPS<br />

Phoenix Control Surface via<br />

<strong>NK</strong>-IPS<br />

1 RU x 44 mm deep<br />

External power pack 5 V @ 2 A<br />

10 W max. inc. plug pack<br />

Dimensions<br />

Power Supply<br />

Power Consumption<br />

Specifications subject to change without prior notice.<br />

Key Features<br />

►►<br />

40 fully illuminated keys<br />

►►<br />

Backlit 16 x 2 LCD display<br />

►►<br />

Fast and simple to change<br />

configurations<br />

►►<br />

Super slim<br />

►►<br />

Individual 5 V power supply<br />

►►<br />

Compact 1 RU design<br />

CPU Upgrade for RCP-KM1<br />

A simple, user-upgradeable controller board<br />

(<strong>NK</strong>M-CPU) is available for users who already<br />

own RCP-KM1 Geneos control panel, providing<br />

a cost-effective solution for migrating devices<br />

to an <strong>NK</strong> <strong>Series</strong> routing switcher system. Ask<br />

your Codan Broadcast representative for more<br />

details.<br />

Ordering Information<br />

RCP-<strong>NK</strong>M<br />

<strong>NK</strong>M-CPU<br />

Remote Control Panel<br />

Controller board for upgrading<br />

existing Geneos RCP-KM1 remote<br />

control panels<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

26


RCP-<strong>NK</strong>1<br />

Remote Control Panel<br />

Key Features<br />

►►<br />

40 fully illuminated keys<br />

►►<br />

Super slim<br />

►►<br />

Key panel can be localised to front of<br />

<strong>NK</strong>-16 routers<br />

►►<br />

Low cost<br />

►►<br />

Phantom powered via the T-Bus<br />

►►<br />

Compact 1 RU design<br />

Ordering Information<br />

RCP-<strong>NK</strong>1 Remote Control Panel<br />

Overview<br />

The RCP-<strong>NK</strong>1 features 40 soft, fully programmable backlit<br />

keys arranged in a 32 + 8 configuration for convenient<br />

function key layout. The RCP-<strong>NK</strong>1 remote control panel can<br />

be used with any size router as XY, cutbus or multi-cutbus.<br />

The RCP-<strong>NK</strong>1 panel may also control multiple router levels,<br />

either tied or as breakaways.<br />

Connected via the T-Bus control system, the RCP-<strong>NK</strong>1 is<br />

phantom-powered by the router to which it is connected.<br />

Multiple control panels can be linked together and powered<br />

from the one router.<br />

One of the most useful and flexible features of the RCP-<strong>NK</strong>1<br />

remote control panel is the ability to install the front key panel<br />

locally to <strong>NK</strong>-16 routers. Localising RCP-<strong>NK</strong>1 remote control<br />

panels ensures that rack space is maximised and cable<br />

connections are minimised. Alternatively, installing panels<br />

remotely means that panels do not necessarily have to be<br />

installed in the immediate vicinity of the routers, and can be<br />

connected and installed in other rooms if required.<br />

Technical Specifications<br />

PANEL<br />

Number of Keys<br />

CONNECTIONS<br />

T-Bus<br />

GENERAL<br />

Configuration<br />

40 x backlit LED<br />

2 x RJ-45 (female, looping)<br />

Web browser via <strong>NK</strong>-IPS<br />

Phoenix Control Surface via<br />

<strong>NK</strong>-IPS<br />

Panel Program Mode<br />

1 RU x 44 mm deep<br />

Phantom Power via T-Bus<br />

Dimensions<br />

Power Supply<br />

Specifications subject to change without prior notice.<br />

27 Codan Broadcast


Control Interface


<strong>NK</strong>-IPS<br />

Network Bridge<br />

Key Features<br />

►►<br />

Interface from any computer on<br />

a network to configure, upgrade,<br />

monitor or remotely control <strong>NK</strong> <strong>Series</strong><br />

devices<br />

►►<br />

Increases flexibility of installation and<br />

fault tolerance of system<br />

►►<br />

8 port hub for T-Bus compliant<br />

devices<br />

►►<br />

Compact size (1 RU, 24 mm depth)<br />

►►<br />

Internal web server<br />

►►<br />

Can be password protected to<br />

prevent unauthorised changes<br />

►►<br />

Front panel indication of<br />

communications status and activity<br />

►►<br />

Network monitoring of connected<br />

<strong>NK</strong> <strong>Series</strong> devices<br />

►►<br />

DHCP and TCP/IP compatible<br />

►►<br />

Easy to install<br />

Ordering Information<br />

<strong>NK</strong>-IPS Network Bridge<br />

Overview<br />

The <strong>NK</strong>-IPS network bridge is the external gateway to all<br />

<strong>NK</strong> <strong>Series</strong> devices for configuration, firmware upgrades,<br />

monitoring and remote control.<br />

The full capabilities of the Phoenix Control Surface, a web<br />

browser or the <strong>NK</strong>-VCP virtual control panel are available<br />

from any computer when connected locally or through a<br />

network to the <strong>NK</strong>-IPS network bridge.<br />

The 8-port hub on the rear of the <strong>NK</strong>-IPS enables flexibility<br />

of installation and isolating groups of devices. In the event<br />

of a critical error, the 8 port hub and connection of devices<br />

in a star layout means that individual device failure does not<br />

affect the entire system.<br />

Alarm status and monitoring is displayed on the <strong>NK</strong>-IPS On<br />

line Devices web page enabling users to locate errors and<br />

troubleshoot problems.<br />

Applications<br />

The <strong>NK</strong>-IPS network bridge is suited to environments where<br />

systems and devices must periodically be reconfigured, for<br />

remote control, or within environments where devices need<br />

to be locked to prevent changes in configuration.<br />

When coupled with the Phoenix Control Surface, a web<br />

browser or the <strong>NK</strong>-VCP virtual control panel, users have<br />

unparalleled versatility for device customisation, firmware<br />

upgrades, alarm display and system operation. At the same<br />

time, the <strong>NK</strong>-IPS can limit access through password control.<br />

The alarm status, visible from the Phoenix Control Surface<br />

or a web browser, shows warnings, and errors. Users can<br />

select the device to display information and a brief alarm<br />

description.<br />

29 Codan Broadcast


<strong>NK</strong>-IPS System Diagram<br />

Phoenix<br />

Control Surface<br />

Web Browser<br />

Legend<br />

T-Bus<br />

Serial<br />

Ethernet<br />

London<br />

Sydney<br />

<strong>NK</strong>-IPS - Network Bridge<br />

Network/<br />

Ethernet Hub<br />

Internet/LAN/VPN<br />

<strong>NK</strong>-IPS - Network Bridge<br />

RCP-<strong>NK</strong>M - Remote Control Panel<br />

RCP-<strong>NK</strong>Q - Remote Control Panel<br />

<strong>NK</strong>-S34 - SDI Video Router<br />

<strong>NK</strong>-MD72 - SD/HD Video Router<br />

<strong>NK</strong>-JBX - Geneos RCP Interface<br />

<strong>NK</strong>-VRC - Virtual <strong>Routing</strong> Core<br />

Geneos Control Panels<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

30


<strong>NK</strong>-VRC<br />

Virtual <strong>Routing</strong> Core<br />

Key Features<br />

►►<br />

Provides virtual routing for<br />

an <strong>NK</strong> <strong>Series</strong> routing switcher<br />

system<br />

►►<br />

1 000 virtual input mappings and<br />

1 000 virtual output mappings<br />

►►<br />

Four status LEDs for visual<br />

error checking<br />

►►<br />

Compact 1 RU design<br />

Ordering Information<br />

<strong>NK</strong>-VRC Virtual <strong>Routing</strong> Core<br />

Overview<br />

The <strong>NK</strong>-VRC offers a virtual routing solution to any <strong>NK</strong> routing<br />

swicther system. The <strong>NK</strong>-VRC offers up to 2 000 virtual source<br />

and destination assignments for the routing system, making<br />

it ideal for environments where resources may be added in<br />

the future.<br />

Virtual routing enables grouping of several physical inputs<br />

and outputs for a switch. The virtual routing capability of the<br />

<strong>NK</strong>-VRC allows the creation of virtual I/O assignments for up<br />

to 1 000 sources and 1 000 destinations.<br />

Users can configure the <strong>NK</strong>-VRC so that the <strong>NK</strong> <strong>Series</strong> routing<br />

switcher system knows which physical input socket to use for<br />

each of the 32 levels and each virtual I/O assignment.<br />

Physical inputs and outputs may be assigned to more than<br />

one virtual label, resulting in a virtual routing table (physical<br />

source/destination and level combinations) larger than the<br />

actual system size.<br />

Technical Specifications<br />

VIRTUAL I/O<br />

Sources<br />

Up to 1000 (per <strong>NK</strong>-VRC)<br />

Destinations Up to 1000 (per <strong>NK</strong>-VRC)<br />

Levels 32<br />

CONNECTIONS<br />

T-Bus<br />

2 x RJ-45 (female, looping)<br />

GENERAL<br />

Configuration<br />

Web browser via <strong>NK</strong>-IPS<br />

Phoenix Control Surface via<br />

<strong>NK</strong>-IPS<br />

1 RU x 25 mm deep<br />

+15 V DC<br />

3 W<br />

Dimensions<br />

Power Supply<br />

Power Consumption<br />

Specifications subject to change without prior notice.<br />

31 Codan Broadcast


<strong>NK</strong>-VRC System Diagram<br />

Phoenix<br />

Control Surface<br />

Web Browser<br />

Network /<br />

Ethernet Hub<br />

RCP-<strong>NK</strong>1 - Remote Control Panel<br />

(Must be enabled for Virtual <strong>Routing</strong>)<br />

<strong>NK</strong>-VRC - Virtual <strong>Routing</strong> Core<br />

<strong>NK</strong>- IPS - Network Bridge<br />

The <strong>NK</strong>-VRC receives virtual data from a remote<br />

control panel<br />

The <strong>NK</strong>-VRC then sends the physical data to the router<br />

Legend<br />

T-Bus<br />

Ethernet<br />

Upon activation, a switch completion message is<br />

returned to the <strong>NK</strong>-VRC<br />

The <strong>NK</strong>-VRC converts the physical data to virtual data<br />

and returns it to the panel<br />

Router Levels<br />

<strong>NK</strong>-D16, <strong>NK</strong>-S34<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

32


<strong>NK</strong>-JBX<br />

Geneos RCP Interface<br />

Key Features<br />

►►<br />

Enables existing Geneos panels to<br />

control an <strong>NK</strong> <strong>Series</strong> routing switcher<br />

system<br />

►►<br />

Connects up to 252 panels<br />

►►<br />

Enables multiple <strong>NK</strong>-JBX units to be<br />

connected<br />

►►<br />

Compact 1RU design<br />

Supported Panels<br />

►<br />

►<br />

RCU-251/RCP-251*<br />

Compact Controller<br />

►<br />

►<br />

RCU-252/RCP-SN<br />

SpinKnob Controller<br />

►<br />

►<br />

RCU-348/RCP-K*<br />

Kameleon Controller<br />

►<br />

►<br />

SK-x/RCP-SKx<br />

SK <strong>Series</strong> Kameleon Controllers 1–4<br />

*Please note that while still supported by the <strong>NK</strong>-JBX,<br />

manufacture of this panel has been discontinued<br />

Ordering Information<br />

<strong>NK</strong>-JBX<br />

Geneos RCP Interface<br />

Overview<br />

The <strong>NK</strong>-JBX is an expansion module giving users the ability<br />

to integrate Geneos control panels into an <strong>NK</strong> <strong>Series</strong> routing<br />

switcher system. The <strong>NK</strong>-JBX connects directly to the T-Bus<br />

and may connect up to 252 panels. Each panel can then be<br />

easily configured via a web browser or the Phoenix Control<br />

Surface. The <strong>NK</strong>-JBX supports bi-directional communication<br />

with each panel.<br />

Each <strong>NK</strong>-JBX can control a subset of 255 inputs, 255 outputs<br />

and 8 levels from the total of 65 535 inputs, 65 535 outputs<br />

and 32 levels available within the <strong>NK</strong> <strong>Series</strong> routing switcher<br />

system.<br />

The <strong>NK</strong>-JBX substantially increases the control options for<br />

users of an <strong>NK</strong> <strong>Series</strong> routing switcher who own or wish to<br />

use Geneos control panels.<br />

Technical Specifications<br />

CONNECTIONS<br />

RCP Connections<br />

RCP Communication<br />

T-Bus<br />

GENERAL<br />

Configuration<br />

4 x DB-9 (female)<br />

RS-422<br />

2 x RJ-45 (female, looping)<br />

Web browser via <strong>NK</strong>-IPS<br />

Phoenix Control Surface via<br />

<strong>NK</strong>-IPS<br />

1 RU x 25 mm deep<br />

+15 V DC<br />

3 W<br />

Dimensions<br />

Power Supply<br />

Power Consumption<br />

Specifications subject to change without prior notice.<br />

33 Codan Broadcast


<strong>NK</strong>-JBX System Diagram<br />

Legend<br />

T-Bus<br />

Serial<br />

Ethernet<br />

Phoenix<br />

Control Surface<br />

Web Browser<br />

Network /<br />

Ethernet Hub<br />

<strong>NK</strong>-JBX - Geneos RCP Interface<br />

<strong>NK</strong>-IPS - Network Bridge<br />

Geneos Control Panels<br />

Router Levels<br />

<strong>NK</strong>- D16, <strong>NK</strong>-S34<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

34


<strong>NK</strong>-SCP/A<br />

ASCII/RS-232 Control Interface<br />

Key Features<br />

►►<br />

Allows <strong>NK</strong> <strong>Series</strong> routers to be<br />

controlled from an automation<br />

system or other device (via the ASCII<br />

protocol)<br />

►►<br />

Easy to install and operate<br />

►►<br />

Phantom-powered via the T-Bus<br />

►►<br />

Stand-alone module<br />

Actual Size of <strong>NK</strong>-SCP/A Size<br />

Overview<br />

The <strong>NK</strong>-SCP/A model enables an RS-232<br />

device, such as an automation system or<br />

computer terminal, to control <strong>NK</strong> <strong>Series</strong> routers<br />

using the ASCII protocol. Any combination of<br />

<strong>NK</strong> <strong>Series</strong> routers can be controlled with a<br />

maximum size of 255 inputs and 255 outputs<br />

with up to 8 levels. The bi-directional protocol<br />

includes crosspoint status monitoring and<br />

crosspoint switching. Crosspoint switching<br />

can be performed using individual levels or<br />

through user-defined breakaway mapping.<br />

<strong>NK</strong>-SCP/A System Diagram<br />

Bi-directional communications<br />

<strong>NK</strong>-IPS - Network Bridge<br />

Ordering Information<br />

Computer or<br />

Automation system<br />

<strong>NK</strong>-SCP/A<br />

ASCII/RS232 Control Interface<br />

<strong>NK</strong>-SCP/A<br />

ASCII/RS-232 Control Interface<br />

Legend<br />

T-Bus<br />

Router Levels<br />

<strong>NK</strong>-S16, <strong>NK</strong>-D32<br />

Serial<br />

RCP-<strong>NK</strong>1 - Remote Control Panel<br />

35 Codan Broadcast


<strong>NK</strong>-SCP/K2<br />

RS-485 Control Interface<br />

Overview<br />

The <strong>NK</strong>-SCP/K2 allows Kondor 2 routers to<br />

be extended by utilising <strong>NK</strong> <strong>Series</strong> routers.<br />

Any combination of <strong>NK</strong> <strong>Series</strong> routers can be<br />

added to a Kondor 2 system with a maximum<br />

size of 255 inputs and 255 outputs with up to<br />

8 levels. Kondor 2 inputs, outputs and levels<br />

are directly mapped to <strong>NK</strong> <strong>Series</strong> inputs,<br />

outputs and levels, meaning that no user<br />

mapping is required.<br />

Actual Size of <strong>NK</strong>-SCP/K2<br />

Key Features<br />

►►<br />

Allows <strong>NK</strong> routers to operate as a<br />

Kondor 2/Geneos level<br />

►►<br />

Easy to install and operate<br />

►►<br />

Phantom powered via the T-Bus<br />

►►<br />

Stand-alone box<br />

<strong>NK</strong>-SCP/K2 System Diagram<br />

Uni-directional communications<br />

K2/Geneos RCP<br />

RCP-SN<br />

Geneos CPU<br />

<strong>NK</strong>-SCP/K2<br />

<strong>NK</strong>-IPS - Network Bridge<br />

Router Levels<br />

<strong>NK</strong>-S16, <strong>NK</strong>-D32<br />

Ordering Information<br />

<strong>NK</strong>-SCP/K2 RS-485 Control Interface<br />

PC operating Geneos<br />

software<br />

Kondor 2 - Router Levels<br />

Legend<br />

T-Bus<br />

Serial<br />

Ethernet<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

36


<strong>NK</strong>-GPI<br />

General Purpose Interface<br />

Key Features<br />

►►<br />

16 GPI inputs and outputs<br />

►►<br />

Return/Latch mode<br />

►►<br />

Easy to install and operate<br />

►►<br />

No DIP switches for configuration<br />

►►<br />

Phantom-powered via the T-Bus<br />

►►<br />

Stand-alone module<br />

Overview<br />

The <strong>NK</strong>-GPI is a stand-alone, universal<br />

general purpose interface for the Codan<br />

Broadcast <strong>NK</strong> <strong>Series</strong> family of routers.<br />

Providing both GPI inputs and outputs,<br />

the <strong>NK</strong>-GPI enables flexible GPI control,<br />

configured from a web browser or the<br />

Phoenix Control Surface, via the <strong>NK</strong>-IPS. The<br />

<strong>NK</strong>-GPI also supports both GPI input return<br />

and latch modes.<br />

<strong>NK</strong>-GPI System Diagram<br />

16 GPI Inputs<br />

Ordering Information<br />

16 GPI Outputs<br />

<strong>NK</strong>-GPI<br />

T-Bus<br />

RS-485<br />

<strong>NK</strong>-IPS - Network Bridge<br />

<strong>NK</strong>-GPI<br />

General Purpose Interface<br />

<strong>NK</strong>-S16 - SDI Video Router<br />

CCUs 1-16<br />

1 16<br />

GPI Tallies<br />

RCP-<strong>NK</strong>1 - Remote Control Panel<br />

37 Codan Broadcast


<strong>NK</strong>-RP1<br />

Redundant Power Supply<br />

Overview<br />

The <strong>NK</strong>-RP1 offers a reliable, fault tolerant and fail-safe option<br />

for <strong>NK</strong> <strong>Series</strong> routers and peripheral devices. The <strong>NK</strong>-RP1<br />

supplies redundant power to up to four routers and devices, to<br />

a total power consumption of 100 watts. The <strong>NK</strong>-RP1 provides<br />

GPI outputs to indicate alarms, in the event that one power<br />

supply has failed. The heartbeat LED on the front of the unit<br />

also blinks if one PSU has failed.<br />

During normal operation, the design of the <strong>NK</strong>-RP1 enables<br />

balancing of the power load, delivering high reliability to all<br />

connected routers and devices. When configured as a dualredundant<br />

positive and negative power supply, the <strong>NK</strong>-RP1<br />

has greater than 80% efficiency as a negative power source,<br />

providing both efficient and low-temperature operation.<br />

The <strong>NK</strong>-RP1 comes standard as a positive power rail supply.<br />

A negative power rail option may be installed as an upgrade<br />

by simply removing the front panel and inserting the <strong>NK</strong>-RP1-<br />

NEG option card (required for <strong>NK</strong>-A16/32 and <strong>NK</strong>-V16/32<br />

router levels).<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

Technical Specifications<br />

PERFORMANCE<br />

Input<br />

100 to 240 V @ 1.5 A (47 to 63 Hz)<br />

Positive Output +15 V @ 6.67 A (100 W)<br />

Negative Output –15 V @ 3.33 A (Optional)<br />

Maximum Total Output 100 W<br />

Relative +/– Output See table below<br />

GENERAL<br />

On-board Cooling<br />

Dimensions<br />

2 x 40 mm fans<br />

1 RU x 190 mm deep<br />

Specifications subject to change without prior notice.<br />

Relative Positive/Negative Power Output<br />

POWER DISTRIBUTION (Watts)<br />

POSITIVE POWER 100 90 80 70 60 50 40<br />

NEGATIVE POWER 0 8.4 16.8 25.2 33.6 42 50<br />

Key Features<br />

►►<br />

Fault tolerant power supply option<br />

for <strong>NK</strong> <strong>Series</strong> routers<br />

►►<br />

Supplies redundant power to up to<br />

four routers<br />

►►<br />

GPI alarms for status output<br />

►►<br />

Available in positive rail and<br />

positive/negative rail models<br />

►►<br />

Front access enables easy<br />

replacement of power supply<br />

modules and negative option card<br />

►►<br />

Inexpensive power source for<br />

multiple <strong>NK</strong> <strong>Series</strong> devices<br />

Ordering Information<br />

<strong>NK</strong>-RP1/P<br />

<strong>NK</strong>-RP1/PN<br />

<strong>NK</strong>-RP1-NEG<br />

<strong>NK</strong>-D12/PN<br />

<strong>NK</strong>-S12/P<br />

Positive rail only model<br />

Positive/Negative rail model<br />

Negative option card (field retrofit<br />

to <strong>NK</strong>-RP1/P)<br />

1.2 m PSU cable for <strong>NK</strong> <strong>Series</strong><br />

devices with DB-9 power connector<br />

1.2 m PSU cable for <strong>NK</strong> <strong>Series</strong><br />

devices with Neutrik ® Speakon ®<br />

power connector<br />

38


<strong>NK</strong>-RP1<br />

<strong>NK</strong>-RP1 System Diagram<br />

Supported Devices:<br />

►►<br />

All <strong>NK</strong> <strong>Series</strong> routers<br />

Power<br />

<strong>NK</strong>-RP1<br />

Dual Redundant PSU<br />

Power<br />

►►<br />

<strong>NK</strong>-IPS network bridge<br />

►►<br />

<strong>NK</strong>-VRC virtual routing core<br />

►►<br />

<strong>NK</strong>-JBX Geneos RCP interface<br />

Device Connectors<br />

<strong>NK</strong>-IPS - Network Bridge<br />

DB-9:<br />

►►<br />

All <strong>NK</strong>-164 router levels<br />

►►<br />

All <strong>NK</strong>-16 router levels<br />

►►<br />

All <strong>NK</strong>-32 router levels<br />

►►<br />

<strong>NK</strong>-IPS network bridge<br />

►►<br />

<strong>NK</strong>-VRC virtual routing core<br />

►►<br />

<strong>NK</strong>-JBX Geneos RCP interface<br />

Neutrik ® Speakon ® :<br />

►►<br />

All <strong>NK</strong>-64 router levels<br />

<strong>NK</strong>-S34 - SDI Video Router<br />

<strong>NK</strong>-V16 - Analogue Video Router<br />

RCP-<strong>NK</strong>1 - Remote Control Panel<br />

<strong>NK</strong>-D64 - AES/EBU Digital Audio Router<br />

RCP-<strong>NK</strong>1 - Remote Control Panel<br />

Legend<br />

T-Bus<br />

Distributed Power<br />

39 Codan Broadcast


Phoenix Control Surface


A Single Point Solution<br />

Key Features<br />

►►<br />

Provides a graphical user<br />

interface for configuration of<br />

<strong>NK</strong> <strong>Series</strong> devices<br />

►►<br />

Save and restore functionality<br />

IPS Explorer<br />

Lists all connected devices.<br />

Document Tabs<br />

Tabbed view enables multiple devices<br />

to be viewed and edited quickly.<br />

Device Configuration<br />

Graphically displays configuration<br />

options for all devices on T-Bus.<br />

Properties Pane<br />

Enables quick editing of<br />

device properties.<br />

►►<br />

Future-proof design<br />

►►<br />

Allows off-line editing of<br />

devices<br />

►►<br />

Secure access via USB<br />

hardware key<br />

►►<br />

Automatic or manual software<br />

updates from the Codan<br />

Broadcast website<br />

►►<br />

Java-based software<br />

File Explorer<br />

Displays saved templates<br />

and firmware files.<br />

Online Help<br />

Direct online help for<br />

selected configuration field.<br />

Details Pane<br />

Shows brief description of<br />

selected configuration field.<br />

Main View<br />

View can be customised to suit<br />

any requirement.<br />

Automatic Updates<br />

Update icon shows when<br />

new or updated modules are<br />

available for installation.<br />

Overview<br />

Surface. Some devices have a custom module, or plug-in,<br />

with a more intuitive configuration interface (for example, <strong>NK</strong><br />

The Overview Phoenix Control Surface provides an enhanced graphical Surface. Some devices have a custom module, or plug-in,<br />

<strong>Series</strong> remote control panels). Custom modules also enable<br />

user interface (GUI) solution for locating, configuring and with a more intuitive configuration interface (for example, <strong>NK</strong><br />

The Phoenix Control Surface provides an enhanced graphical users to only install the modules that they require.<br />

controlling <strong>NK</strong> <strong>Series</strong> devices.<br />

<strong>Series</strong> remote control panels). Custom modules also enable<br />

user interface (GUI) solution for locating, configuring and The users Phoenix to only USB install Security the modules Key allows that they secure require. access to device<br />

Ordering Information<br />

Phoenix controlling unlocks <strong>NK</strong> <strong>Series</strong> the devices. potential for system growth through<br />

configuration and control. To restrict program access when<br />

<strong>NK</strong>-PCS Phoenix Control Surface<br />

the off-line editing feature, enabling users to configure new The Phoenix USB Security Key allows secure access to device<br />

Phoenix unlocks the potential for system growth through users are not at their workstation, the Security Key may be<br />

devices before they’ve even been installed and connected to configuration and control. To restrict program access when<br />

the off-line editing feature, enabling users to configure new removed without having to exit the program.<br />

the system.<br />

users are not at their workstation, the Security Key may be<br />

devices before they’ve even been installed and connected to<br />

removed without having to exit the program.<br />

Any the system. device that can be configured by the <strong>NK</strong>-IPS network<br />

bridge may also be configured by the Phoenix Control<br />

Any device that can be configured by the <strong>NK</strong>-IPS network<br />

bridge may also be configured by the Phoenix Control<br />

41 Codan Broadcast


Locating Devices<br />

Network /<br />

Ethernet Hub<br />

<strong>NK</strong>-GPI<br />

Phoenix Control<br />

Surface<br />

<strong>NK</strong>-IPS - Network Bridge<br />

RCP-<strong>NK</strong>1 - Remote Control Panel<br />

<strong>NK</strong>-A32 - Stereo Analogue Audio Router<br />

<strong>NK</strong>-V32 - Analogue Video Router<br />

Whether your system is spread over different rooms, different<br />

cities or even different countries, Phoenix can locate and<br />

display devices over LAN, VPN or the Internet.<br />

Upon start-up, Phoenix broadcasts a search command over<br />

the T-Bus control system via any connected <strong>NK</strong>-IPS network<br />

bridges. All compatible and connected devices return their<br />

status, and Phoenix displays the relevant status information.<br />

Any alarms are indicated by coloured labels on the device in<br />

the IPS Explorer window.<br />

Legend<br />

T-Bus<br />

Ethernet<br />

The IPS Explorer displays all connected devices, and<br />

also becomes the central point for configuration and<br />

system management. The IPS Explorer allows users to<br />

save device configuration, load new firmware and send<br />

new configurations to devices without opening the device<br />

configuration.<br />

Router Alarms<br />

The IPS Explorer enables users to<br />

visually monitor the health of their<br />

routing system.<br />

There are four degrees of alarm<br />

urgency: green (normal operation),<br />

yellow (warning), orange (error)<br />

and red (critical error).<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

42


Intuitive Configuration<br />

Router Interface<br />

The default configuration screen for<br />

<strong>NK</strong> <strong>Series</strong> routers provides simple and<br />

efficient configuration for all <strong>NK</strong> <strong>Series</strong><br />

router levels.<br />

The RCP-<strong>NK</strong>M Custom Module<br />

The custom module for the RCP-<strong>NK</strong>M<br />

remote control panel provides simple<br />

and intuitive graphical editing of key<br />

layout and key definitions.<br />

The RCP-<strong>NK</strong>Q Custom Module<br />

The custom module for the RCP-<strong>NK</strong>Q<br />

remote control panel provides simple<br />

and intuitive graphical editing of keys,<br />

LCD displays and menus.<br />

Phoenix provides simple, intuitive configuration for all <strong>NK</strong> <strong>Series</strong> devices.<br />

Any new <strong>NK</strong> <strong>Series</strong> devices may be configured immediately, without<br />

having to upgrade the program or install new modules. Some devices<br />

have their own custom module design, providing user-friendly features.<br />

Custom modules provide a natural and interactive interface for<br />

configuration. The custom modules for remote control panels display a<br />

visual representation of the panel, allowing users to edit buttons easily<br />

with the mouse.<br />

When used with the off-line editing feature, custom modules enable<br />

users to get a feel for devices before they are connected to the system.<br />

43 Codan Broadcast


Advanced Control<br />

London<br />

Sydney<br />

Network /<br />

Ethernet Hub<br />

<strong>NK</strong>-IPS - Network Bridge<br />

Phoenix Control<br />

Surface<br />

Internet/LAN/VPN<br />

RCP-<strong>NK</strong>Q - Remote Control Panel<br />

<strong>NK</strong>-IPS - Network Bridge<br />

RCP-<strong>NK</strong>M - Remote Control Panel<br />

<strong>NK</strong>-MD72 - SD/HD Video Router<br />

<strong>NK</strong>-S34 - SDI Video Router<br />

Legend<br />

T-Bus<br />

<strong>NK</strong>-A64 - Analogue Audio Router<br />

<strong>NK</strong>-D32 - AES/EBU Audio Router<br />

Ethernet<br />

In this distributed <strong>NK</strong> <strong>Series</strong> routing switcher system,<br />

the Phoenix Control Surface in London can control<br />

or configure equipment located in Sydney.<br />

The <strong>NK</strong> Switchboard enables users to locally<br />

or remotely control an entire <strong>NK</strong> <strong>Series</strong> routing<br />

switcher system. If required, it is also possible<br />

to control multiple systems, alternating between<br />

each as needed. Each system may be configured<br />

by the <strong>NK</strong>-IPS independently of other systems on<br />

the network.<br />

The <strong>NK</strong> Switchboard also allows users to protect<br />

outputs as well as providing machine control<br />

functionality. Each system may be configured<br />

on-the-fly to display and control almost any<br />

amount of inputs, outputs and levels.<br />

Any protected outputs are displayed on the<br />

<strong>NK</strong> Switchboard, including protects activated<br />

from control panels or other Phoenix users.<br />

The <strong>NK</strong> Switchboard<br />

The <strong>NK</strong> Switchboard provides users with a simple interface<br />

for crosspoint switching and router status display.<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

44


Advanced Features<br />

The advanced features of the Phoenix Control Surface provide users with unique options for system<br />

management and control. The USB key provides secure access for engineers and system integrators.<br />

The save and restore function is especially useful for applications where devices need to be reconfigured<br />

regularly and quickly. Off-line editing allows users to edit device configurations while the system itself is<br />

on line or on air. Another significant feature of Phoenix is the ability to send one configuration to multiple<br />

devices, making it perfect for redundant applications.<br />

The File Explorer<br />

The File Explorer provides users with quick and easy access<br />

to saved device configurations and firmware files.<br />

Save and Restore<br />

The Phoenix Control Surface can save any number of system<br />

configurations to disk, making the <strong>NK</strong> <strong>Series</strong> ideal for applications<br />

such as OB vans where significant and rapid configuration<br />

changes are required. Configurations may each be saved to a<br />

separate folder and recalled when required.<br />

Off-line Editing<br />

The off-line editing feature of Phoenix makes it the ideal solution<br />

when planning for growth of an <strong>NK</strong> <strong>Series</strong> routing switcher system.<br />

Default device configurations may be accessed from the Phoenix<br />

Installation CD and edited before the device has been physically<br />

installed into the existing system.<br />

Secure Access<br />

The Phoenix USB key provides secure access for device configuration and system control. The USB key<br />

may be removed when users leave their workstation, without having to exit the program itself. This ensures<br />

that Phoenix can stay on line 24 hours a day if required, and the ability to change system configuration<br />

can be restricted to selected engineers.<br />

Upgrading Device Firmware<br />

The Phoenix USB Key<br />

Support for New <strong>NK</strong> <strong>Series</strong> Devices<br />

Newly released and future products in the <strong>NK</strong> <strong>Series</strong> family can be edited straight away, but many new<br />

devices will have a custom module for easier configuration. Simply download the custom module for the<br />

newly purchased hardware module for an immediate start!<br />

The Phoenix Control Surface allows easy uploading of firmware to devices. New firmware may be<br />

downloaded from the Codan Broadcast website and displayed in the File Explorer in Phoenix.<br />

45 Codan Broadcast


Automatic Software Updates<br />

Phoenix is composed of a series of independent modules, allowing each module to be updated without<br />

the need to update the program core itself. If a specific device module does require a core update for<br />

functionality, the dependency is resolved automatically when installing updates from the Update Centre.<br />

The Update Centre may be used to update the Phoenix Control Surface core modules, library modules,<br />

existing device modules as well as install new custom modules.<br />

Updates may also be installed manually if the updates have been downloaded directly from the Codan<br />

Broadcast website.<br />

The Automatic Update Check can be enabled to search the Update Centre for module updates,<br />

enhancements and additions, keeping Phoenix up-to-date when features are implemented.<br />

System Requirements for Phoenix Control Surface<br />

CPU<br />

RAM<br />

Intel Pentium 600 MHz CPU or equivalent (Recommended: 1 GHz or greater)<br />

128 MB RAM (Recommended: 256 MB RAM or greater)<br />

Display 1024 x 768<br />

Operating System<br />

Hard Disk Space<br />

USB<br />

Other<br />

Microsoft Windows® XP Professional or Home Edition<br />

Up to 40 MB of available hard disk space<br />

1 x USB port for hardware key<br />

Java Runtime Environment 1.5 (available on Phoenix Installation CD)<br />

<strong>NK</strong>-IPS (with firmware 2.0 or greater)<br />

<strong>NK</strong> <strong>Series</strong> routing switcher system operating with either v1.x or v2.x firmware<br />

The Update Centre<br />

An example of how the Update Centre displays new or<br />

upgradeable modules for installation. In this example,<br />

the <strong>NK</strong>-VRC editor is a new module that may be installed;<br />

other modules have upgrades available.<br />

Package Contents<br />

1 x Installation CD-ROM<br />

1 x Hardware Key<br />

1 x Quick Start Guide<br />

Specifications subject to change without prior notice.<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

46


Ordering Information<br />

<strong>NK</strong> <strong>Series</strong> Router Levels<br />

CAT. CODE SIZE ROUTER FORMAT PSU MODEL<br />

<strong>NK</strong>-A164 16 x 4 Stereo Analogue Audio Router <strong>NK</strong>-PN1<br />

<strong>NK</strong>-A16 16 x 16 Stereo Analogue Audio Router <strong>NK</strong>-PN1<br />

<strong>NK</strong>-A32 32 x 32 Stereo Analogue Audio Router <strong>NK</strong>-PN1<br />

<strong>NK</strong>-A64 64 x 64 Stereo Analogue Audio Router <strong>NK</strong>-P3<br />

<strong>NK</strong>-D164/75 16 x 4 AES/EBU Digital Audio Router (75 Ω) <strong>NK</strong>-P1<br />

<strong>NK</strong>-D16/75 16 x 16 AES/EBU Digital Audio Router (75 Ω) <strong>NK</strong>-P1<br />

<strong>NK</strong>-D32/75 32 x 32 AES/EBU Digital Audio Router (75 Ω) <strong>NK</strong>-P1<br />

<strong>NK</strong>-D64/75 64 x 64 AES/EBU Digital Audio Router (75 Ω) <strong>NK</strong>-P4<br />

<strong>NK</strong>-D164/110 16 x 4 AES/EBU Digital Audio Router (110 Ω) <strong>NK</strong>-P1<br />

<strong>NK</strong>-D16/110 16 x 16 AES/EBU Digital Audio Router (110 Ω) <strong>NK</strong>-P1<br />

<strong>NK</strong>-D32/110 32 x 32 AES/EBU Digital Audio Router (110 Ω) <strong>NK</strong>-P1<br />

<strong>NK</strong>-D64/110 64 x 64 AES/EBU Digital Audio Router (110 Ω) <strong>NK</strong>-P4<br />

<strong>NK</strong>-M16 16 Port Machine Control (RS-422) Router <strong>NK</strong>-P1<br />

<strong>NK</strong>-M32 32 Port Machine Control (RS-422) Router <strong>NK</strong>-P1<br />

<strong>NK</strong>-MD164 16 x 4 SD/HD Video Router <strong>NK</strong>-P1<br />

<strong>NK</strong>-MD16 16 x 16 SD/HD Video Router <strong>NK</strong>-P1<br />

<strong>NK</strong>-MD34 34 x 34 SD/HD Video Router <strong>NK</strong>-P1<br />

<strong>NK</strong>-MD72 72 x 72 SD/HD Video Router <strong>NK</strong>-P2<br />

<strong>NK</strong>-S164 16 x 4 SDI Video Router <strong>NK</strong>-P1<br />

<strong>NK</strong>-S16 16 x 16 SDI Video Router <strong>NK</strong>-P1<br />

<strong>NK</strong>-S34 32 x 32 SDI Video Router <strong>NK</strong>-P1<br />

<strong>NK</strong>-S72 72 x 72 SDI Video Router <strong>NK</strong>-P2<br />

<strong>NK</strong>-V164 16 x 4 Analogue Video Router <strong>NK</strong>-PN1<br />

<strong>NK</strong>-V16 16 x 16 Analogue Video Router <strong>NK</strong>-PN1<br />

<strong>NK</strong>-V32 32 x 32 Analogue Video Router <strong>NK</strong>-PN1<br />

<strong>NK</strong> <strong>Series</strong> Router Levels Power Supplies<br />

CAT. CODE<br />

<strong>NK</strong>-RP1/P<br />

<strong>NK</strong>-RP1/PN<br />

<strong>NK</strong>-RP1-NEG<br />

<strong>NK</strong>-P1<br />

<strong>NK</strong>-P2<br />

<strong>NK</strong>-P3<br />

<strong>NK</strong>-P4<br />

<strong>NK</strong>-PN1<br />

PRODUCT DESCRIPTION<br />

Redundant Power Supply (Positive rail only model)<br />

Redundant Power Supply (Positive/Negative rail model)<br />

Negative option card (for existing <strong>NK</strong>-RP1 Positive models)<br />

Stand-alone Positive PSU (50 W) for selected <strong>NK</strong>-16/<strong>NK</strong>-32 routers<br />

Stand-alone Positive PSU (72 W) for selected <strong>NK</strong>-64 routers<br />

Stand-alone Positive PSU (100 W) for selected <strong>NK</strong>-64 routers<br />

Stand-alone Positive PSU (50 W) for selected <strong>NK</strong>-64 routers<br />

Stand-alone Positive/Negative PSU (42 W) for selected <strong>NK</strong>-16/<br />

<strong>NK</strong>-32 routers<br />

47 Codan Broadcast


Kondor 2 Router Levels<br />

CAT. CODE PRODUCT DESCRIPTION PSU MODEL<br />

K2-RFA-15<br />

K2-RFA-1551<br />

Kondor 2 Router Levels Power Supplies<br />

CAT. CODE<br />

PSU-55PP<br />

PSU-55PN<br />

Kondor 2 ‘15’ Rack Frame Kit<br />

Kondor 2 ‘1551’ Rack Frame Kit<br />

K2-144XH 144 x 144 SD / HD (Multi-Definition) Matrix Board PSU-55PP<br />

K2-IMD/OMD<br />

K2-ISE/OSN<br />

SD/HD (Multi-Definition) Input (EQ)/Output 8 Ch<br />

SDI Input (EQ)/Output 8 ch<br />

K2-64XV 64 x 64 Analogue Video Matrix Board PSU-55PN<br />

K2-IV/OV<br />

Analogue Video Input/Output 8 Ch<br />

K2-64XD 64 x 64 AES Matrix Board PSU-55PP<br />

K2-IDE/ODE<br />

AES Input/Output 16 ch<br />

K2-64XA 64 x 64 x 1 Analogue Audio Matrix Board PSU-55PN<br />

K2-IA/OA<br />

<strong>NK</strong>-K2<br />

Analogue Audio Input/Output 16 ch<br />

Kondor 2 Interface<br />

PRODUCT DESCRIPTION<br />

PSU-55PP 1000 W Power Supply for SD, HD and AES<br />

PSU-55PN 500 W/500 W +/- Power Supply for Video and An.<br />

Audio<br />

Remote Control Panels<br />

CAT. CODE PRODUCT DESCRIPTION<br />

RCP-<strong>NK</strong>1 Remote Control Panel<br />

RCP-<strong>NK</strong>M Remote Control Panel comes with 5 V PSU<br />

RCP-<strong>NK</strong>Q Remote Control Panel comes with 5 V PSU<br />

Control Interface and Software<br />

CAT. CODE PRODUCT DESCRIPTION PSU MODEL<br />

<strong>NK</strong>-IPS Network Bridge <strong>NK</strong>-P1<br />

<strong>NK</strong>-GPI General Purpose Interface N/A (Phantom)<br />

<strong>NK</strong>-JBX Geneos RCP Interface <strong>NK</strong>-P1<br />

<strong>NK</strong>-SCP/A ASCII/RS-232 Control Interface N/A (Phantom)<br />

<strong>NK</strong>-SCP/K2 RS-485 Control Interface N/A (Phantom)<br />

<strong>NK</strong>-VRC Virtual <strong>Routing</strong> Core <strong>NK</strong>-P1<br />

<strong>NK</strong>-PCS Phoenix Control Surface N/A<br />

<strong>NK</strong> <strong>Series</strong> <strong>Routing</strong> <strong>Switchers</strong><br />

48


With over 20 years experience, Codan Broadcast delivers you the best<br />

in leading edge broadcast equipment through innovation, experience<br />

and unsurpassed service and support. Our wide range of signal<br />

management products offers extraordinary reliability and value to suit<br />

TV broadcasters, pre- and post-production houses, and government and<br />

news facilities.<br />

We design and manufacture routers and switchers, interface products<br />

and signal converters and audio monitoring bridges that operate<br />

seamlessly with your broadcast operations. Our commitments include<br />

product designs that meet the highest specifications and industry<br />

standards, backed by a 3 year parts and labour warranty. We provide the<br />

best available service and support as well as fast, on time deliveries.<br />

Head Office (Australia): T: +61 (0)8 8336 0600 E: broadcast@codan.com.au<br />