2045 LX Centrifugal Pump DISASSEMBLY OF LX PUMP Remove rear seal. 19
2045 LX Centrifugal Pump DISASSEMBLY OF LX PUMP Check this area inside shaft for wear. Hydraulic Motor Shaft Severe wear may occur to pump shaft at a point where splines of hydraulic motor contact shaft splines. Since it may not be possible to see this wear from the outside of shaft, the internal splines in shaft should be cleaned thoroughly with solvent and then inspected under a strong light. If the wear in this area exceeds .030, shaft should be discarded and no attempt to reuse or repair should be made. When splines become worn beyond the .030 limit, it becomes difficult and sometimes impossible to disengage hydraulic motor from pump shaft. If this occurs, the only solution is to cut motor shaft or splined end of pump shaft off with a torch. 20
- Page 1 and 2: 2045 LX Centrifugal Pump
- Page 3 and 4: 2045 LX Centrifugal Pump DISASSEMBL
- Page 5 and 6: 2045 LX Centrifugal Pump DISASSEMBL
- Page 7 and 8: 2045 LX Centrifugal Pump DISASSEMBL
- Page 9 and 10: 2045 LX Centrifugal Pump DISASSEMBL
- Page 11 and 12: 2045 LX Centrifugal Pump DISASSEMBL
- Page 13 and 14: 2045 LX Centrifugal Pump DISASSEMBL
- Page 15 and 16: 2045 LX Centrifugal Pump DISASSEMBL
- Page 17 and 18: 2045 LX Centrifugal Pump DISASSEMBL
- Page 19: 2045 LX Centrifugal Pump DISASSEMBL
- Page 23 and 24: 2045 LX Centrifugal Pump ASSEMBLY O
- Page 25 and 26: 2045 LX Centrifugal Pump ASSEMBLY O
- Page 27 and 28: 2045 LX Centrifugal Pump ASSEMBLY O
- Page 29 and 30: 2045 LX Centrifugal Pump ASSEMBLY O
- Page 31 and 32: 2045 LX Centrifugal Pump ASSEMBLY O
- Page 33 and 34: 2045 LX Centrifugal Pump ASSEMBLY O
- Page 35 and 36: 2045 LX Centrifugal Pump ASSEMBLY O
- Page 37 and 38: 2045 LX Centrifugal Pump ASSEMBLY O
- Page 39 and 40: 2045 LX Centrifugal Pump ASSEMBLY O
- Page 41 and 42: 2045 LX Centrifugal Pump ASSEMBLY O
- Page 43 and 44: 2045 LX Centrifugal Pump ASSEMBLY O
- Page 45 and 46: 2045 LX Centrifugal Pump ASSEMBLY O
- Page 47 and 48: 2045 LX Centrifugal Pump GAR
- Page 49 and 50: 2045 LX Centrifugal Pump GARDNER DE
- Page 51 and 52: 2045 LX Centrifugal Pump GARDNER DE
- Page 53: Drilling & Production Pumps Gardner
<strong>2045</strong> <strong>LX</strong> <strong>Centrifugal</strong> <strong>Pump</strong><br />
DISASSEMBLY OF <strong>LX</strong> PUMP<br />
Check this area inside<br />
shaft for wear.<br />
Hydraulic<br />
Motor Shaft<br />
Severe wear may occur to pump shaft at a point where<br />
splines of hydraulic motor contact shaft splines. Since it may not<br />
be possible to see this wear from the outside of shaft, the internal<br />
splines in shaft should be cleaned thoroughly with solvent and<br />
then inspected under a strong light. If the wear in this area<br />
exceeds .030, shaft should be discarded and no attempt to reuse<br />
or repair should be made.<br />
When splines become worn beyond the .030 limit, it becomes<br />
difficult and sometimes impossible to disengage hydraulic motor<br />
from pump shaft. If this occurs, the only solution is to cut motor<br />
shaft or splined end of pump shaft off with a torch.<br />