GROUND HANDLING AND<br />

SERVICING HANDBOOK<br />

HARD COPY IS UNCONTROLLED. ONCE PRINTED, THIS PAGE MUST NOT BE RETAINED FOR FUTURE REFERENCE.<br />

BEFORE USING, MAKE SURE THIS HARD COPY IS THE LATEST ISSUE.<br />

• De-energize the aircraft (GHSH TASK 24-41-00-860-802-A/200).<br />

(5) Open the access door 523BL.<br />

C. Fuel Tank - Water Draining<br />

WARNING: DO NOT LET JET FUEL AND LUBRICATING OILS TOUCH<br />

YOU. THESE FLUIDS CAUSE INJURY TO THE SKIN.<br />

(1) Do the steps that follow to drain the water from the fuel tanks:<br />

(a) Use the fuel sampler (GSE 022) to push the drain valve poppet up to<br />

open the drain valve. Refer to GSE Appendix.<br />

NOTE: The drain valve closes when you remove the fuel sampler<br />

(GSE 022) from the drain valve poppet. Drain several<br />

times until the fuel in the container shows no water. Examine<br />

the collected fuel for contamination, especially at the<br />

fuel/water interface.<br />

(b) Remove the fuel sampler (GSE 022) after you drain a sufficient<br />

amount of fuel.<br />

NOTE: Make sure that the drain valve poppet is in the closed position<br />

and that there is no fuel leak.<br />

(2) Visually examine the collected fuel for contamination. If you see microorganisms<br />

or other unwanted matter in the fuel, use a Fuel Microorganisms<br />

Test Kit (Microb Monitor 2) to check for the presence of microorganisms.<br />

Obey the instructions of the test kit manufacturer.<br />

NOTE: Refer to the full instructions (aviation fuel item) to do the procedures.<br />

(4) If the Fuel Microorganisms Test Kit (Microb Monitor 2) detects the presence<br />

of microorganisms, please use the contact information given in the GHSH<br />

Introduction for the applicable maintenance action to wing fuel tank decontamination.<br />

WARNING: WHEN YOU DISCARD DANGEROUS CONSUMABLE<br />

MATERIALS, USE PROCEDURES THAT AGREE WITH<br />

LOCAL REGULATIONS. THESE MATERIALS CAN<br />

CAUSE INJURY TO PERSONS AND CONTAMINATION OF<br />

THE ENVIRONMENT.<br />

(5) Discard the collected fuel.<br />

(6) Do this procedure again for the other drain valve.<br />

D. Job Close-Up<br />

(1) Close the access door 523BL.<br />

(2) Remove the grounding cable(s) from the aircraft (GHSH TASK 20-40-02-<br />

910-801-A/200).<br />

EFFECTIVITY: ALL<br />

12-11-00-680-801-A/300<br />

Page 302<br />

Rev.04 - JUN 16/09<br />