18.02.2015 Views

EMB-500 - Embraer

EMB-500 - Embraer

EMB-500 - Embraer

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GROUND HANDLING AND<br />

SERVICING HANDBOOK<br />

HARD COPY IS UNCONTROLLED. ONCE PRINTED, THIS PAGE MUST NOT BE RETAINED FOR FUTURE REFERENCE.<br />

BEFORE USING, MAKE SURE THIS HARD COPY IS THE LATEST ISSUE.<br />

(c) Close the window shades.<br />

(d) Set the gust locks.<br />

CAUTION: MAKE SURE THAT ALL COVERS ARE IN GOOD CON-<br />

DITIONS, WITH NO DAMAGE AND FREE OF LINTS. IF<br />

YOU DO NOT OBEY THIS PRECAUTION, DAMAGE TO<br />

THIS EQUIPMENT CAN OCCUR.<br />

(e) Install the covers to these parts:<br />

1. Pitot probe (GSE 009).<br />

2. Pitot-static probe (GSE 003).<br />

3. Dual static port (GSE 008).<br />

4. Engine (GSE 030).<br />

(f) Cover the outlet and inlet openings that follow with a cotton fabric or<br />

equivalent attached to the aircraft skin with adhesive tape:<br />

1. Ram air inlet<br />

2. Ground cooling fan inlet.<br />

3. Ground cooling fan exhaust.<br />

(g) Close all the doors and access panels.<br />

(h) Make sure that wheel chocks are installed.<br />

(i) Where there are freezing or ice conditions, do the subsequent step:<br />

1. Remove, drain and storage the waste tank. Refer to GHSH TASK<br />

12-15-03-600-801-A/300.<br />

NOTE: For matter of hygiene, we recommend that the waste<br />

tank be serviced.<br />

EFFECTIVITY: ALL 10-10-00-<strong>500</strong>-801-A/200<br />

Page 202<br />

Rev.06 - OCT 09/09<br />

Copyright © by <strong>EMB</strong>RAER S.A - All rights reserved - See title page for details.