TRANE ®<br />

Model Number Description<br />

MCDP Model Nomenclature<br />

M C D P 0 7 5 B 1 0 0 0 0 A A<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

Digit 1,2,3<br />

Digit 4<br />

M C D<br />

P<br />

InDoor Unit, Horizontal Discharge / Cooling Only<br />

Development Sequence<br />

Digit 5,6,7<br />

0 7 5<br />

Nominal Cooling Capacity, MBH<br />

075 = 75 MBH<br />

100 = 100 MBH<br />

125 = 125 MBH<br />

MCDP Models<br />

MCDP 075<br />

MCDP 100 / 125<br />

MTR, Kw<br />

D = 0.75<br />

E = 1.1<br />

Digit 8<br />

B<br />

Electrical Rating / Utilization Range<br />

B = 220 - 240V / 1Ph / 50 Hz<br />

Digit 9<br />

Digit 10<br />

Digit 11<br />

Digit 12<br />

Digit 13<br />

Digit 14<br />

1<br />

0<br />

0<br />

0<br />

0<br />

A<br />

Factory Mounted Control<br />

1 = DOL Starter c/w Temperature Controller<br />

Future Use<br />

Future Use<br />

Future Use<br />

Future Use<br />

Minor Design Sequence<br />

Digit 15<br />

A Service Indicator<br />

TTH Model Nomenclature<br />

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

T T H 1 2 5 Q D 1 D 0 0 0 B A<br />

Digit 1,2<br />

Digit 3<br />

Digit 4,5,6<br />

Digit 7<br />

Digit 8<br />

Digit 9<br />

T T<br />

H<br />

1 5 0<br />

Q<br />

D<br />

1<br />

InDoor Unit / Cooling Only<br />

Air Flow Configuration<br />

H = Horizontal Discharge<br />

V = Vertical Discharge<br />

Nominal Cooling Capacity, MBH<br />

150 = 150 MBH 200 = 200 MBH<br />

175 = 175 MBH 240 = 240 MBH<br />

Development Sequence<br />

Electrical Rating / Utilization Range<br />

B = 220 - 240V / 1Ph / 50 Hz<br />

Factory Mounted Control<br />

1 = DOL Starter c/w Temperature Controller<br />

Digit 10<br />

Digit 11<br />

Digit 12<br />

Digit 13<br />

G<br />

0<br />

0<br />

0<br />

Installed Motor kW<br />

Future Use<br />

Future Use<br />

Future Use<br />

TTH Models<br />

TTH 150/175<br />

TTH 200<br />

TTH 240<br />

Std. MTR, kW<br />

G = 2.2<br />

H = 3.0<br />

J = 4.0<br />

Oversize MTR; Kw<br />

J = 4.0<br />

K = 5.5<br />

K = 5.5<br />

Digit 14<br />

Digit 15<br />

B<br />

A<br />

Minor Design Sequence<br />

B = Second. (Year 2006, TTH/BDHB Casing Rationalization)<br />

Service Indicator<br />

7