17.02.2015 Views

Emotron FDU 2.0 Variable Speed Drive

Emotron FDU 2.0 Variable Speed Drive

Emotron FDU 2.0 Variable Speed Drive

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Addendum<br />

11.5.4 Digital Outputs [540]<br />

and 11.5.5 Relays [550]<br />

The brake trip/warning is signalled on digital/relay outputs<br />

via new selections in Menus Digital Out 1-2 [541] - [542]<br />

and Menu Relay 1 to 3 [551] - [55C]<br />

Digital Out 1 to 2 [541] - [542]<br />

Default<br />

Brk Fault<br />

BrkNotEngage<br />

11.7.2 Status [720]<br />

The brake trip/warning is signalled as “Brake” in Menu<br />

Warning[722] and Trip message log [810].<br />

Warning [722].<br />

Ready<br />

88 Tripped on brake fault (not released)<br />

89<br />

... ...<br />

Warning and continued operation (keep<br />

torque) due to Brake not engaged during<br />

stop.<br />

14 Brake<br />

... ...<br />

541 DigOut 1<br />

Stp Brk Fault<br />

A<br />

722 Warnings<br />

Stp Brake<br />

12.1 Trips, warnings and limits<br />

New trip/warning message, “Brake” added<br />

Trip/Warning<br />

messages<br />

Selections<br />

Trip<br />

(Normal/<br />

Soft)<br />

... ... ... ...<br />

Brake Via DigIn Normal<br />

... ... ... ...<br />

12.2 Trip conditions, causes and<br />

remedial action<br />

New trip/warning message “Brake” added.<br />

Trip<br />

condition<br />

Possible<br />

Cause<br />

.... ... ...<br />

Brake<br />

<strong>Drive</strong> tripped<br />

on brake fault<br />

(not released)<br />

or Brake not<br />

engaged<br />

warning<br />

during stop<br />

... ... ...<br />

Remedy<br />

Warning<br />

indicators<br />

(Area D)<br />

- Check Brake acknowledge<br />

signal wiring to selected digital<br />

input.<br />

- Check programming of digital<br />

input DigIn 1-8, [520].<br />

- Check circuit breaker feeding<br />

mechanical brake circuit.<br />

- Check mechanical brake if<br />

acknowledge signal is wired from<br />

brake limit switch.<br />

- Check brake contactor.<br />

11.2.7 Trip Auto reset/Trip conditions<br />

[250]<br />

The brake trip auto reset is activated and delay time is specified<br />

by the new parameter in Menu Brake Fault [25V].<br />

Brake Fault [25V]<br />

Select the preferred way to react to an alarm trip.<br />

Default Off<br />

25V Brk Fault<br />

Stp Off<br />

A<br />

Off 0 Autoreset not activated.<br />

1 - 3600s 1 - 3600s Brake fault auto reset delay time.<br />

<strong>Emotron</strong> AB 01-4934-01r1 Brake acknowledge functionality 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!