Emotron FDU 2.0 Variable Speed Drive

Emotron FDU 2.0 Variable Speed Drive Emotron FDU 2.0 Variable Speed Drive

17.02.2015 Views

1. Introduction FDU is used most commonly to control and protect pump and fan applications that put high demands on flow control, process uptime and low maintenance costs. It can also be used for e.g. compressors and blowers. The used motor control method is V/Hz-control. Several options are available, listed in chapter 13. page 157, that enable you to customize the variable speed drive for your specific needs. NOTE: Read this instruction manual carefully before starting installation, connection or working with the variable speed drive. The following symbols can appear in this manual. Always read these first before continuing: NOTE: Additional information as an aid to avoid problems. ! CAUTION: Failure to follow these instructions can result in malfunction or damage to the variable speed drive. WARNING: Failure to follow these instructions can result in serious injury to the user in addition to serious damage to the variable speed drive. HOT SURFACE: Failure to follow these instructions can result in injury to the user. Users This instruction manual is intended for: • installation engineers • maintenance engineers • operators • service engineers 1.1 Delivery and unpacking Check for any visible signs of damage. Inform your supplier immediately of any damage found. Do not install the variable speed drive if damage is found. The variable speed drives are delivered with a template for positioning the fixing holes on a flat surface. Check that all items are present and that the type number is correct. 1.2 Using of the instruction manual Within this instruction manual the abbreviation “VSD” is used to indicate the complete variable speed drive as a single unit. Check that the software version number on the first page of this manual matches the software version in the variable speed drive. With help of the index and the contents it is easy to track individual functions and to find out how to use and set them. The Quick Setup Card can be put in a cabinet door, so that it is always easy to access in case of an emergency. 1.3 Type code number Fig. 1 gives an example of the type code numbering used on all variable speed drives. With this code number the exact type of the drive can be determined. This identification will be required for type specific information when mounting and installing. The code number is located on the product label, on the front of the unit. FDU48-175-54 C E – – – A – N N N N A N – Position number: 1 2 3 4 5 6 7 8 9101112131415161718 Fig. 1 Type code number Motors The variable speed drive is suitable for use with standard 3- phase asynchronous motors. Under certain conditions it is possible to use other types of motors. Contact your supplier for details. Position for 003- 046 Position for 060- 1500 1 1 VSD type Configuration 2 2 Supply voltage FDU VFX 40/48=400 V mains 50/52=525 V mains 69=690 V mains 3 3 Rated current (A) continuous -003=2.5 A - -1500=1500 A Emotron AB 01-4428-01r2 Introduction 5

Position for 003- 046 4 4 Protection class 5 5 Control panel 6 6 EMC option 7 7 8 8 - 9 Brake chopper option Stand-by power supply option Safe stop option (Not valid for 003-046) 20=IP20 54=IP54 –=Blank panel C=Standard panel E=Standard EMC (Category C3) F=Extended EMC (Category C2) I=IT-Net –=No chopper B=Chopper built in D=DC+/- interface –=No SBS S=SBS included –=No safe stop T=Safe stop incl. (Only 090-1500) 9 10 Brand label A=Emotron 10 - 11 11 Painted VSD (Only valid for 003-046) Coated boards, option A=Standard paint B=White paint RAL9010 A=Standard boards V=Coated boards 12 12 Option position 1 N=No option 13 13 Option position 2 C=Crane I/O E=Encoder 14 14 Option position 3 P=PTC/PT100 I=Extended I/O S=Safe Stop (only 003-046) 15 15 Option position, communication N=No option D=DeviceNet P=Profibus S=RS232/485 M=Modbus/TCP 16 16 Software type A=Standard 17 17 18 18 Position for 060- 1500 Configuration Motor PTC. (Only valid for 003-046) Gland kit. (Only valid for 003- 046) N=No option P=PTC –=Glands not included G=Gland kit included 1.4 Standards The variable speed drives described in this instruction manual comply with the standards listed in Table 1. For the declarations of conformity and manufacturer’s certificate, contact your supplier for more information or visit www.emotron.com. 1.4.1Product standard for EMC Product standard EN(IEC)61800-3, second edition of 2004 defines the: First Environment (Extended EMC) as environment that includes domestic premises. It also includes establishments directly connected without intermediate transformers to a low voltage power supply network that supplies buildings used for domestic purposes. Category C2: Power Drive System (PDS) of rated voltage

Position<br />

for 003-<br />

046<br />

4 4 Protection class<br />

5 5 Control panel<br />

6 6 EMC option<br />

7 7<br />

8 8<br />

- 9<br />

Brake chopper<br />

option<br />

Stand-by power supply<br />

option<br />

Safe stop option<br />

(Not valid for<br />

003-046)<br />

20=IP20<br />

54=IP54<br />

–=Blank panel<br />

C=Standard panel<br />

E=Standard EMC<br />

(Category C3)<br />

F=Extended EMC<br />

(Category C2)<br />

I=IT-Net<br />

–=No chopper<br />

B=Chopper built in<br />

D=DC+/- interface<br />

–=No SBS<br />

S=SBS included<br />

–=No safe stop<br />

T=Safe stop incl.<br />

(Only 090-1500)<br />

9 10 Brand label A=<strong>Emotron</strong><br />

10 -<br />

11 11<br />

Painted VSD<br />

(Only valid for<br />

003-046)<br />

Coated boards,<br />

option<br />

A=Standard paint<br />

B=White paint<br />

RAL9010<br />

A=Standard<br />

boards<br />

V=Coated boards<br />

12 12 Option position 1 N=No option<br />

13 13 Option position 2<br />

C=Crane I/O<br />

E=Encoder<br />

14 14 Option position 3<br />

P=PTC/PT100<br />

I=Extended I/O<br />

S=Safe Stop (only<br />

003-046)<br />

15 15<br />

Option position, communication<br />

N=No option<br />

D=DeviceNet<br />

P=Profibus<br />

S=RS232/485<br />

M=Modbus/TCP<br />

16 16 Software type A=Standard<br />

17 17<br />

18 18<br />

Position<br />

for 060-<br />

1500<br />

Configuration<br />

Motor PTC. (Only<br />

valid for 003-046)<br />

Gland kit.<br />

(Only valid for 003-<br />

046)<br />

N=No option<br />

P=PTC<br />

–=Glands not<br />

included<br />

G=Gland kit<br />

included<br />

1.4 Standards<br />

The variable speed drives described in this instruction manual<br />

comply with the standards listed in Table 1. For the declarations<br />

of conformity and manufacturer’s certificate,<br />

contact your supplier for more information or visit<br />

www.emotron.com.<br />

1.4.1Product standard for EMC<br />

Product standard EN(IEC)61800-3, second edition of 2004<br />

defines the:<br />

First Environment (Extended EMC) as environment that<br />

includes domestic premises. It also includes establishments<br />

directly connected without intermediate transformers to a<br />

low voltage power supply network that supplies buildings<br />

used for domestic purposes.<br />

Category C2: Power <strong>Drive</strong> System (PDS) of rated voltage