2 7 3<br />

Setting<br />

o<br />

F<br />

F<br />

Serial comm. contact broken<br />

(alarm code F15)<br />

Default: 2<br />

Range: oFF, 1, 2, 3, 4<br />

oFF<br />

Serial comm. contact broken disabled<br />

1 Warning<br />

2 Coast<br />

3 Stop<br />

4 Brake<br />

7.5 Selection of control sources<br />

Setting up the control source has to be done from the local <strong>MSF</strong> <strong>2.0</strong> control<br />

panel.<br />

2 0 0<br />

Setting<br />

2<br />

Control source<br />

Default: 2 (remote control)<br />

Range: 1, 2, 3<br />

1 Control panel.<br />

2 Remote control.<br />

3 Serial communication control.<br />

In all control sources it is possible to readout all the bit map (see 7.8)<br />