FURNACE & CABLE COOLING<br />
mm inch mm inch bar psi mm inch % kg/m lb/ft<br />
13 1/2 25 0,98 10 150 0,460 0,310<br />
19 3/4 31 1,22 10 150 0,620 0,420<br />
25 1 41 1,61 10 150 1,080 0,730<br />
32 1 1/4 48 1,89 10 150 1,310 0,880<br />
38 1 1/2 54 2,13 10 150 1,300 0,870<br />
51 2 67 2,64 10 150 1,940 1,300<br />
NA LA NEU CEU SA AP AU<br />
249LE<br />
Air-<strong>water</strong> delivery 10 bar (150 psi)<br />
non conductive<br />
Tube: White EPDM<br />
Reinforcement: High tensile textile cords<br />
Cover: Blue EPDM - heat, abrasion and ozone resistant<br />
Use: Non conductive air and <strong>water</strong> delivery in foundry applications<br />
Safety factor: 4:1<br />
Temperature: -40 °C +150 °C (-40 °F +300 °F)<br />
FURNACE & CABLE COOLING<br />
mm inch mm inch bar psi mm inch % kg/m lb/ft<br />
19 3/4 31 1,22 10 150 0,590 0,400<br />
25 1 37 1,46 10 150 0,740 0,500<br />
32 1 1/4 46 1,81 10 150 1,110 0,750<br />
38 1 1/2 52 2,05 10 150 1,290 0,870<br />
51 2 65 2,56 10 150 1,690 1,140<br />
NA LA NEU CEU SA AP AU<br />
mm inch mm inch bar psi mm inch % kg/m lb/ft<br />
51 2 63 2,48 10 150 255 10,00 100 1,600 1,080<br />
60 2 3/8 72 2,83 10 150 300 12,00 100 1,980 1,330<br />
63 2 1/2 75 2,95 10 150 300 12,00 90 2,070 1,390<br />
76 3 88 3,46 10 150 330 13,00 90 2,470 1,660<br />
80 3 1/8 92 3,62 10 150 400 15,75 90 2,660 1,790<br />
90 3 1/2 102 4,02 10 150 450 17,50 90 3,040 2,040<br />
102 4 114 4,49 10 150 510 20,00 90 3,430 2,310<br />
NA LA NEU CEU SA AP AU<br />
254AL<br />
Furnace cooling 10 bar (150 psi) - soft wall<br />
Tube: Black SBR<br />
Reinforcement: High tensile textile cords<br />
Cover: Black SBR - resin coated dust free fibreglass cover<br />
Use: General purpose <strong>water</strong> delivery in furnace cooling applications.<br />
Specially designed to withstand heat, splashes of molten metal and<br />
open flame<br />
Safety factor: 3:1<br />
Temperature: -30 °C +80 °C (-22 °F +176 °F)<br />
Cover resistant up to 540 °C (1000 °F)<br />
203AL<br />
Furnace cooling 10 bar (150 psi) - hard wall<br />
Tube: Black SBR<br />
Reinforcement: High tensile textile cords with embedded steel helix wire<br />
Cover: Black SBR - resin coated dust free fibreglass cover<br />
Use: General purpose <strong>water</strong> suction and delivery in furnace cooling<br />
applications.<br />
Specially designed to withstand heat, splashes of molten metal and<br />
open flame<br />
Safety factor: 3:1<br />
Temperature: -30 °C +80 °C (-22 °F +176 °F)<br />
Cover resistant up to 540 °C (1000 °F)<br />
mm inch mm inch bar psi mm inch % kg/m lb/ft<br />
13 1/2 25 0,98 10 150 0,440 0,300<br />
16 5/8 28 1,10 10 150 0,500 0,340<br />
19 3/4 33 1,30 10 150 0,700 0,470<br />
25 1 39 1,54 10 150 0,860 0,580<br />
32 1 1/4 48 1,89 10 150 1,250 0,840<br />
38 1 1/2 54 2,13 10 150 1,460 0,980<br />
51 2 67 2,64 10 150 1,860 1,250<br />
63 2 1/2 81 3,19 10 150 2,290 1,540<br />
76 3 96 3,78 10 150 3,170 2,130<br />
NA LA NEU CEU SA AP AU<br />
957LL<br />
Cable cooling 10 bar (150 psi)<br />
non conductive<br />
Tube: White EPDM<br />
Reinforcement: High tensile textile cords<br />
Cover: White non conductive EPDM, heat resistant -<br />
resin coated dust free fibreglass cover<br />
Use: Non conductive cable cooling in electric furnaces.<br />
Specially designed to withstand heat, splashes of molten metal and<br />
open flame<br />
Safety factor: 4:1<br />
Temperature: -40 °C +120 °C (-40 °F +248 °F)<br />
Cover resistant up to 540 °C (1000 °F)<br />
44 www.alfagomma.com<br />
Dimensions shown may be changed without notice