Typical Construction Code<br />

Example:<br />

SG02V / 3C / B / SM / B2 / X<br />

A rectangular attenuator with splitter elements, constructed from<br />

galvanised sheet steel.<br />

The unit shall be delivered to site split in two sections in length,<br />

and splitters shall be installed in the vertical plane.<br />

The unit casing shall have a high pressure rating, with 30mm<br />

profile flanges at both ends. The attenuator shall be protected<br />

by bubble wrap.<br />

The attenuator shall be provided with side splitters and the infill<br />

shall be protected by Melinex polyester film. The unit shall have<br />

a base colour polyester powder paint finish on external surfaces<br />

only. The unit shall also have a special feature.<br />

Construction Code Format<br />

The first three sections of the construction code, up to and<br />

including the packing are always shown:<br />

Example:<br />

SG02V / 3C / L<br />

Optional features, paint options and special features are only<br />

shown if applicable, and in the order as they are shown in the<br />

construction codes layout on the previous page.<br />

Further examples:<br />

<br />

<br />

<br />

SG02V / 3C / B / S / B2<br />

SG02V / 3C / H / SM / X<br />

SG02V / 3C / L / X<br />

Other Materials<br />

This brochure only provides details on attenuators constructed<br />

from galvanised sheet steel. However <strong>CAICE</strong> can also provide<br />

attenuators constructed from a range of other materials where<br />

required:<br />

Stainless steel - for duct systems handling corrosive chemically<br />

laden air, or with high standards of cleanliness, or for external<br />

applications, etc.<br />

Plastic - for duct systems handling corrosive chemically laden<br />

air, etc. Various types of plastic are available depending on the<br />

application.<br />

Heavy duty galvanised steel - for industrial applications, or<br />

where casings need to be welded for very high pressure duct<br />

systems, etc. Rolled steel angle (RSA) flanges would normally<br />

be provided for these types of application.<br />

Generally attenuators can be constructed in these materials to<br />

the same sizes as the standard galvanised sheet steel products<br />

that are detailed in this brochure. However if you require more<br />

detailed information on attenuators constructed in alternative<br />

materials then please contact our sales personnel for further<br />

assistance.<br />

Fire Rating<br />

All <strong>CAICE</strong> attenuators detailed within this brochure are capable<br />

of maintaining their internal air circulating area when subjected<br />

to an internal temperature of 300° C for a period of 120 minutes.<br />

These attenuators are therefore suitable for installation within<br />

smoke or heat exhaust systems, providing the internal<br />

temperature does not exceed 300° C for a period longer than<br />

120 minutes.<br />

Warrington Fire Research have undertaken an independent<br />

assessment and compiled a report that supports this statement.<br />

For more onerous conditions or where proprietary systems, such<br />

as Flameshield are specified, matching attenuators can also be<br />

provided by enhancing the constructional specification of the<br />

products.<br />

Fire rating is a diverse topic, and therefore if you do require<br />

more details on the attenuator options that we can provide then<br />

please contact our sales personnel for further assistance.<br />

www.caice.co.uk<br />