Caice/Flameshield Fire Rated <strong>Attenuator</strong>s<br />

Fire Rating<br />

The risk of fire in any type of building is an ever present concern<br />

and so all measures must be taken at the design stages to<br />

ensure the risks are minimised.<br />

Where a fire strategy is to be adopted, it is usual for certain parts<br />

of the ventilation ductwork to be fire rated, in order to offer the<br />

necessary protective measures for the finished development.<br />

For each individual development, the degree of fire rating<br />

required will depend on a number of variables. The employment<br />

of a specialist sub-contractor to advise on the required fire rating<br />

treatment is therefore essential to ensure that that all relevant<br />

current standards and legislation are complied with.<br />

Fire Rated <strong>Attenuator</strong>s<br />

<strong>Attenuator</strong>s form part of the ventilation systems and must<br />

therefore meet the fire rating requirements for the ductwork in<br />

which they are installed.<br />

There are various specialist fire rating sub-contractors all<br />

offering different systems, however one such company is<br />

Flameshield Ltd.<br />

Flameshield<br />

As one of the UK’s leading providers of fire-rated ductwork,<br />

Flameshield offer the UK’s first non-coated fire-rated ductwork<br />

system that receives LPCB certification.<br />

Made from galvanised sheet steel, the system withstands fire<br />

tests to BS476 Part 24 and BS5588 Part 9, without the need for<br />

additional spray to be applied to the external surface.<br />

Caice / Flameshield Alliance<br />

Caice have worked closely with Flameshield, and are now able<br />

to offer a full range of rectangular galvanised steel fire rated<br />

attenuators. This key strategic alliance offers a number of<br />

benefits to our clients:<br />

1. <strong>Attenuator</strong>s manufactured by Caice are fully approved<br />

and certified for use with the Flameshield range of fire<br />

rated ductwork, removing any doubts over compatibililty<br />

issues.<br />

2. Both Caice and Flameshield use the same manufacturing<br />

technique, where integral flanges are formed from the<br />

parent material of the duct casing. This provides integral<br />

strength and reduced air leakage when compared to<br />

conventional flanging systems such as Doby or MEZ.<br />

3. Caice attenuators and Flameshield duct sections are<br />

visually similar, so there is no mismatch when aesthetics<br />

are a consideration.<br />

4. No spray means no application or curing time, and no<br />

risk of damaging expensive coatings once the product is<br />

on site. <strong>Attenuator</strong>s and ductwork can be produced with<br />

the quickest possible turnaround times at competitive<br />

prices.<br />

Standards and Certification<br />

Flameshield ductwork and Caice/Flameshield attenuators meet<br />

all current standards:<br />

BS 476: Part 24: 1987 (ISO 6944)<br />

BS 9999 (formerly BS 5588)<br />

<br />

<br />

<br />

<br />

DW/144<br />

DW/172<br />

Document B1 (means of escape)<br />

Document B3 (internal fire spread structure)<br />

Flameshield ductwork has been tested by BRE and has also<br />

been certified by the LPCB (Loss Prevention Certification<br />

Board).<br />

26<br />

www.caice.co.uk<br />

<strong>CAICE</strong> <strong>Attenuator</strong> Brochure