Hot Shield PTC High Operating Temperature Smoke ... - Actionair
Hot Shield PTC High Operating Temperature Smoke ... - Actionair
Hot Shield PTC High Operating Temperature Smoke ... - Actionair
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Hot</strong><strong>Shield</strong> <strong>PTC</strong> TM<br />
For Circular and Flat Oval Dampers spigots are 3mm under duct size.<br />
Basic Dampers<br />
Dampers with Installation Systems<br />
Dampers with DWFX-F<br />
HEVAC / HVCA IF<br />
Circular Dampers Series 2601 and 3601<br />
=<br />
DUCT DIA<br />
100 - 150<br />
=<br />
50<br />
OVERALL FLANGE WIDTH = 370mm<br />
OVERALL FLANGE HEIGHT = 395MM<br />
50<br />
OVERALL WIDTH OF INSTALLATION<br />
FRAME IS 316mm<br />
OVERALL HEIGHT OF INSTALLATION<br />
FRAME IS 340mm<br />
90<br />
=<br />
25<br />
DUCT<br />
DIAMETER<br />
100 - 150<br />
108<br />
28<br />
200<br />
CIRCULAR<br />
CIRCULAR<br />
=<br />
25<br />
200<br />
25<br />
25<br />
25<br />
65 38 78<br />
38<br />
65<br />
85<br />
82<br />
DUCT DIA<br />
=<br />
151 - 199<br />
=<br />
OVERALL FLANGE WIDTH = 420mm<br />
OVERALL FLANGE HEIGHT = 445mm<br />
OVERALL WIDTH OF INSTALLATION<br />
FRAME IS 366mm<br />
OVERALL HEIGHT OF INSTALLATION<br />
FRAME IS 390mm<br />
90<br />
DUCT<br />
= DIAMETER =<br />
151 - 199<br />
25 250<br />
28<br />
25<br />
50<br />
25 250<br />
25<br />
25 CIRCULAR<br />
CIRCULAR<br />
110<br />
85<br />
108<br />
82<br />
65 38 78<br />
38<br />
65<br />
50<br />
DUCT DIA<br />
50<br />
200 - 950<br />
OVERALL FLANGE WIDTH =<br />
DUCT DIA. + 220mm<br />
OVERALL FLANGE HEIGHT =<br />
DUCT DIA. + 245mm<br />
50<br />
OVERALL WIDTH OF INSTALLATION<br />
FRAME IS DUCT DIA + 166mm<br />
OVERALL HEIGHT OF INSTALLATION<br />
FRAME IS DUCT DIA + 190mm<br />
90<br />
DUCT<br />
DIAMETER<br />
50<br />
75<br />
50<br />
25<br />
110<br />
108<br />
110<br />
50<br />
200 - 950<br />
25 Duct<br />
28<br />
25<br />
25 Duct<br />
DIA + 50mm*<br />
25 CIRCULAR<br />
CIRCULAR<br />
85<br />
82<br />
FOR 951 – 1000mm<br />
DUCT DIM + 30mm<br />
65 38 78<br />
38<br />
65<br />
Flat Oval Dampers Series 2701 and 3701<br />
50 DUCT WIDTH * 50<br />
300 – 950<br />
75<br />
50<br />
25<br />
OVERALL FLANGE WIDTH =<br />
DUCT WIIDTH + 220mm<br />
OVERALL FLANGE HEIGHT =<br />
DUCT HEIGHT + 245mm<br />
50<br />
110<br />
OVERALL WIDTH OF INSTALLATION<br />
FRAME IS DUCT WIDTH + 166mm<br />
OVERALL HEIGHT OF INSTALLATION<br />
FRAME IS DUCT HEIGHT +190mm<br />
90<br />
108<br />
DUCT<br />
HEIGHT<br />
50<br />
200 - 500<br />
25 DUCT WIDTH + 50mm* 25<br />
28<br />
25 DUCT HEIGHT<br />
+50MM<br />
25 FLAT OVAL<br />
65 38 78<br />
38 65<br />
FLAT OVAL<br />
85<br />
82<br />
FOR 951 – 1000mm<br />
DUCT DIM + 30mm<br />
*<br />
www.actionair.co.uk<br />
9