10 STORAGE<br />

ENGINE STORAGE<br />

- When the engines are not for more than 6 months, they have to be protected performing the operations described in<br />

the following pages.<br />

- If the engine is not to be used for extensive periods, check the storage area conditions and the type of packaging and<br />

make sure that these are suitable for correct storage.<br />

If necessary, cover the engine with a proper protective sheet.<br />

- Avoid storing the engine in direct contact with the ground, in environments that are humid and exposed to bad weather,<br />

near high voltage electric lines, etc.<br />

Important<br />

If, after the first 6 months, the engine is still not used, it is necessary to carry out a further measure to extend<br />

the protection period (see “Protective treatment”).<br />

PROTECTIVE TREATMENT<br />

1 - Pour in the engine housing AGIP RUSTIA C protective oil up to the maximum level.<br />

2 - Fill up with fuel containing 10% AGIP RUSTIA NT.<br />

3 - Make sure that the coolant is up to the maximum level.<br />

4 - Start the engine and keep it idle at minimum speed for some minutes.<br />

5 - Bring the engine to ¾ of the maximum speed for 5÷10 minutes.<br />

6 - Turn off the engine.<br />

7 - Empty out completely the fuel tank.<br />

8 - Spray SAE 10W on the exhaust and intake manifolds.<br />

9 - Seal the exhaust and intake ducts to prevent foreign bodies from entering.<br />

10 - Thoroughly clean all external parts of the engine using suitable products.<br />

11 - Treat non-painted parts with protective products (AGIP RUSTIA NT).<br />

12 - Loosen the alternator/fan belt.<br />

13 - Cover the engine with a proper protective sheet.<br />

Caution - Warning<br />

In countries in which AGIP products are not available, find an equivalent product (with specifications: MIL-L-<br />

21260C).<br />

Important<br />

Maximum every 24 months of inactivity, the engine must be started up by repeating all "Engine Storage"<br />

operations.<br />

- 78 - FOCS Workshop Manual_cod. 1.5302.858_1° ed_ rev. 00