7<br />
Fuel system<br />
Static injection advance tuning<br />
If the injection advance value found does not correspond to the<br />
previously described value, adjust the screw E and repeat the test.<br />
Rotating screw E by ½ turn will change the injection advance by 5°.<br />
If turned clockwise, injection is advanced.<br />
In the opposite direction, injection is delayed.<br />
155<br />
Preliminary steps to pump/injector unit delivery balancing test<br />
Closing the oilhole<br />
To perform this test you must remove the rocker arms cover and<br />
close hole 1 with an M 8x1.25 or M 10x1.5 screw (on latest model<br />
engines) not longer than 8 mm. Also remove the copper gasket.<br />
If the camshaft and rocker arms are dry, lubricate them with engine<br />
oil.<br />
Note: If you only want to check the nozzle it is not necessary to<br />
balance the deliveries; provided that when you dismount the<br />
rod you do not loosen adjusting screws 1 and 2 (fig. 160).<br />
156<br />
Test head B assembly<br />
Remove fuel pipe A and mount one test head B in its place per<br />
pump/injector.<br />
The test heads complete with pipes are supplied together with<br />
instrument ref. 7104-1460-069.<br />
157 158<br />
Instrument connection<br />
Place the instrument 1, se.no. 7104-1460-127 at least 20 cm above<br />
the pump/injector level.<br />
Connect pipe A (outlet from every instrument test piece) with pipe A<br />
(inlet of every pump/injector) and pipe B (return to the instrument)<br />
with pipe B (outlet from the pump/injector).<br />
Open tap 2 and 3 of each pipe and fill the instrument with diesel.<br />
Start the engine and bring it to 1500 rpm idle running.<br />
Close the fuel supply to the engine from the instrument’s tank using<br />
lever 4 and after 1 minute observe the levels in the test piece.<br />
If a level goes down more than the others it is necessary to decrease<br />
the delivery of the corresponding pump (see below) and vice versa<br />
to increase the delivery if the level increases.<br />
159<br />
- 66 - FOCS Workshop Manual_cod. 1.5302.858_1° ed_ rev. 00