7306 Charging Generator
7306 Charging Generator
7306 Charging Generator
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Simco-Ion<br />
Electrostatic <strong>Charging</strong> Systems<br />
SPECIFICATION SHEET<br />
ION Impact TM MODEL <strong>7306</strong><br />
Electrostatic charging using ionization is often the most elegant and<br />
efficient way of accomplishing many physical tasks in handling paper and<br />
plastic films, webs and sheets. The users who design charging into their<br />
process seldom go back to mechanical means of accomplishing the same<br />
task.<br />
A charging generator and charge applicator make up an electrostatic<br />
charging system. A single charging system or a combination of two<br />
charging systems are used for “pinning” or “tacking” together sheets<br />
and webs of film or paper. Typical applications include manufacturing<br />
of binders, chill roll edge pinning on cast film lines, lamination, in-mold<br />
labeling (IML), plastic bag manufacturing, roll transfer, shrink wrapping<br />
and others.<br />
<strong>7306</strong> <strong>Charging</strong> <strong>Generator</strong>,<br />
single-polarity model, with<br />
the 7430 <strong>Charging</strong> Bar<br />
An ITW Company<br />
Simco-Ion, Hatfield, PA USA<br />
www.simco-ion.com<br />
In the press room and in the bindery, charging applications are a part of<br />
several processes, such as ribbon tacking, chill roll tacking, inserting cards<br />
into magazines and catalogs in saddle stitchers and perfect bound lines,<br />
and catalog stacking.<br />
Simco-Ion<br />
Hatfield, PA USA<br />
www.simco-ion.com<br />
(215) 97-0590<br />
An ITW Company<br />
I O N I M P A C T 7 3 0 6 C H A R G I N G G E N E R A T O R<br />
The ION Impact <strong>7306</strong> <strong>Charging</strong> <strong>Generator</strong> is a 30 kV, 5 mA solid-state<br />
microprocessor-based, quick set-up high voltage DC power supply for<br />
use with specified charge applicators. The <strong>7306</strong> <strong>Charging</strong> <strong>Generator</strong> is<br />
available in three versions:<br />
• With negative output voltage<br />
• With a positive output voltage<br />
• With outputs of both positive and negative polarities<br />
Using the multifunctional display and controls, the <strong>7306</strong> generator is easily<br />
set up to operate in the CONSTANT CURRENT mode, with timed charging<br />
action, output level alarms and remote output control features. In the<br />
CONSTANT CURRENT mode, the system maintains stable and strong<br />
pinning power even as the ambient conditions change or the ionizing<br />
electrodes get contaminated with time or the material’s properties vary.<br />
The <strong>7306</strong> generator can also operate in the Constant Voltage mode<br />
in applications where the load impedance changes and the charging<br />
system must provide the required stability.<br />
The <strong>7306</strong> can be fully integrated into a process for:<br />
• Remote activation of the high voltage output<br />
• Remote output voltage or charging current adjustment via a choice of<br />
10K pot, 4-20 mA or 0-10V-signal follower<br />
• Remote output voltage and charging current analog output signals<br />
• RS-485 communications<br />
A large, easy-to-read LED readout in the front panel of the generator<br />
displays both charging current and operating voltage, making it simple to<br />
adjust, monitor and control the static charging process.<br />
The <strong>7306</strong> generator is mounted using four holes located on two mounting<br />
flanges. The <strong>7306</strong> charging generator uses convenient twist-and-lock<br />
quick-disconnect high-voltage connectors for charge applicators, such<br />
as Ion model 7430 <strong>Charging</strong> Bar.<br />
SEE SPECIFICATIONS FOR 7430/4 AND 7402 CHARGING BARS, AND<br />
7430 MATRIX CHARGER IN THEIR RESPECTIVE SPECIFICATION<br />
SHEETS.<br />
1<br />
DS-<strong>7306</strong>_SI - 06/11
SP1<br />
SP2<br />
AL1<br />
AL2<br />
SoF<br />
An ITW Company<br />
Current Setpoint<br />
(single 5 mA /dual<br />
Voltage Setpoint<br />
(single 31 kV /dual<br />
Current Over Alarm (mA)<br />
Voltage Under Alarm (kV)<br />
Software Version<br />
Simco-Ion, Hatfield, PA USA<br />
www.simco-ion.com<br />
2.5 mA max)<br />
31 kV max)<br />
Pr1<br />
Pr2<br />
Pr3<br />
Pr4<br />
Pr5<br />
HV On enable (Unlock/Lock)<br />
Output Voltage limit (kV)<br />
Timer Mode<br />
(Disabled/Timed ON/Delayed OFF/Delayed ON)<br />
Delay timer (sec)<br />
Current Shutdown (Disabled/Enabled)<br />
Pr6-Pr0 See Instruction Manual<br />
<br />
SPECIFICATION SHEET<br />
I O N I M P A C T 7 3 0 6 C H A R G I N G G E N E R A T O R<br />
The true value of the dual-polarity version of the <strong>7306</strong> is realized<br />
when a charging application requires two charge applicators, one<br />
positive and the other negative. Common dual polarity applications<br />
include electrostatic ribbon tacking on heatset printing presses, in-line<br />
finishing, and electrostatic magazine tacking on incline stackers where<br />
finished magazines pass between two 7430 Matrix Chargers and get<br />
electrostatically compressed for packaging in neat and strong bundles.<br />
Dual-polarity <strong>7306</strong> <strong>Generator</strong> Powers Two<br />
7430 Matrix Chargers<br />
1 - positive Matrix Charger; 2 - negative<br />
Matrix Charger; 3 - dual-polarity model of the<br />
<strong>7306</strong> charging generator<br />
1<br />
0.24”<br />
(6mm)<br />
2<br />
FRONT VIEW<br />
ALARM<br />
3<br />
An ITW Company<br />
Simco-Ion, Hatfield, PA USA<br />
w.simco-ion.com<br />
SIDE VIEW<br />
SPECIFICATIONS<br />
Configurations:<br />
Mains Voltage:<br />
Power Consumption:<br />
Output (<strong>7306</strong>P & -N):<br />
Output (<strong>7306</strong>D):<br />
Voltage Rise Time:<br />
Voltage Fall Time:<br />
Maximum Load:<br />
Operation Temp:<br />
Maximum RH:<br />
Dimensions:<br />
Weight:<br />
Installation Category:<br />
P/N 91-<strong>7306</strong>P - Positive voltage output (2 connectors)<br />
P/N 91-<strong>7306</strong>N - Negative voltage output (2 connectors)<br />
P/N 91-<strong>7306</strong>D - Dual polarity voltage outputs (2<br />
connectors for each polarity)<br />
Selectable 115 or 230 VAC, 50/60 Hz<br />
400 VA at full load<br />
0-31 kV ±10% @ 0-5 mA, positive or negative<br />
0-31 kV ±10% @ 0-2.5 mA, positive and negative<br />