Com.G@te menu Here, the functions (analogue interface, RS232/RS485, ECS-Standby, POCO Alarm) used in connection with an external control (e.g process control system “PCS”) are listed. 42 ANALOGUE-INTERFACE: Config. input Config. output Go back USE EXTERNAL SIGNAL TO: No action Switch to 2nd setp. 2nd set-point selectiv Internal / Process Temp. contr. on/off Enable machine Go back COM.G@TE: Analogue interface RS232/RS485 ECS Standby POCO Alarm Return to main menu POCO ACTION: OFF Check act. value External Alarm Unipump/PCS Control by RS232 Check process temp. Unipump with echo Programmerr Check int. temp. abs. Check proc. temp. abs. Go back DIGITAL INTERFACE: Select RS232/485 Baud rate Slave address (LAI) Go back

Analogue Interface AIF INPUT FUNCTION: AIF ->Input off AIF ->Internal temp. AIF ->Process Temp. AIF ->Set-point AIF ->Heating 0-100% AIF ->Power AIF ->Pump speed setp. AIF ->Pump press. setp. Go back ADJUST: Adj. current value Enter in table Go back Adjustment of the current measured value by input of the reference value ANALOGUE INPUT: Means: AIF -> Input off Action on analogue error: Switch off Action on cable break: Trigger an alarm Configuration In/Out 4.00mA -> 274.0 °C 20.00mA -> 274.0 °C Actual AIF input values: 0 Bit -> 0.00mA->0.00 °C Continue: Press Encoder button ANALOGUE-INTERFACE: Config. input Config. output Go back ANALOGUE INPUT: AIF–Input - Function On cable break Cfg. input range Adjustment On analogue error Display AIF value Reset AIF input Show table values Current / voltage switch Filter constant Go back SHOW TABLE VALUES: ref. val meas. val P1 10485 10485 P2 52428 52428 WARNING: Following Parameters are going to be removed when resetting the analogue interface Measurement range Adjustment In / output function AIF FILTER CONST: Act. Setting: 0002 Max. Setting 0010 Min. Setting 0000 New setting 0002 CURRENT / VOLTAGE SWITCH: Current Voltage Go back ON CABLE BREAK: Trigger an alarm No alarm, normal operation Go back Temperature T1 Actual setting: -40,00 Max. setting 350,00 Min. setting -150.00 New value: : -40,0 OK ESC OK KEYB Temperature T2 Actual setting -40,00 Max. setting 350,00 Min. setting -150.00 New value: -40,0 ESC OK KEYB ON ANALOGUE ERROR: Switch off Act. 2 nd Set-point Go back 43

Com.G@te menu<br />

Here, the functions (analogue interface, RS232/RS485, ECS-Standby, POCO Alarm)<br />

used in connection with an external control (e.g process control system “PCS”) are<br />

listed.<br />

42<br />

ANALOGUE-INTERFACE:<br />

Config. input<br />

Config. output<br />

Go back<br />

USE EXTERNAL SIGNAL TO:<br />

No action<br />

Switch to 2nd setp.<br />

2nd set-point selectiv<br />

Internal / Process<br />

Temp. contr. on/off<br />

Enable machine<br />

Go back<br />

COM.G@TE:<br />

Analogue interface<br />

RS232/RS485<br />

ECS Standby<br />

POCO Alarm<br />

Return to main menu<br />

POCO ACTION:<br />

OFF<br />

Check act. value<br />

External Alarm<br />

Unipump/PCS<br />

Control by RS232<br />

Check process temp.<br />

Unipump with echo<br />

Programmerr<br />

Check int. temp. abs.<br />

Check proc. temp. abs.<br />

Go back<br />

DIGITAL INTERFACE:<br />

Select RS232/485<br />

Baud rate<br />

Slave address (LAI)<br />

Go back