Operating manual 27.09.2011 CC Heating Thermostats - HUBER

Operating manual 27.09.2011 CC Heating Thermostats - HUBER Operating manual 27.09.2011 CC Heating Thermostats - HUBER

14.11.2012 Views

Main menu The following functions are available: Compact menu Comfort menu Control parameters Acoustic alarm Comfort menu Auto-Start Display modes Clock Enter program Com.G@te (with connected Com.G@te only) Overtemperature protection Compact menu Pump settings Compressor automatic (not valid for all units) Set-point Control parameters Set-point limits Display functions Start & stop Display modes Start ramp E-Grade packages Temperature control mode Enter program User menu - select Factory default Exit Language Limits Overtemperature protection (for units with heating) Program start&stop Protection functions Pump settings Sensor adjustment Service Set-point Set-point limits Settings (others) Software version Start & stop Start ramp Temperature control mode Temperature scale Time scale User menu - config. User menu - select 2nd set-point Web.G@te (with connected Web.G@te only) Exit The individual functions are described in the following pages: 26

Compact menu Control parameters: The default setting is Automatic control parameter. CONFIGURATION MANUAL CONTROL PARAMETERS: Change control parameters Display control parameters Go back Control parameters KPInt. 181.3 200,0 TNInt. 77.6 100,0 TVInt. 0.0 0.0 CONTROL PARAMETERS Internal Cascade jacket control Cascade process Go back Control and Ident. param. KPInt. 181.3 TtInt. 1.4 TNInt. 77.6 TIInt. 7033.2 TVInt. 0.0 KSInt 0.00 SELECT THERMAL FLUID: No specification M120.08.02 M90.200.02 (DW-Therm) M90.055.03 (Sil. oil) M40.165.10 (Sil.oil) FILLING QUANTITY: Please enter the approx. thermal fluid filling capacity Temperature control in a bath… … CONTROL PARAMETERS: Select auto./ manual Config. automatic Config. manual param. Reset control parameters Display Parameter Return to main menu Select auto./ manual Automatic control parameters AUTOMATIC CONFIGURATION: Find control parameters Control dynamics Display control parameters Fluid properties Go back THERMAL FLUID: Thermal fluid Circulation volume Bypass usage Show fluid Go back BYPASS: If there is a partial short cut through a bypass, please choose “yes”. AUTOMATIC / MANUAL SELECTION: Manual control parameters Automatic control parameters Go back AUTOMATIC MODE: Fast identification With preliminary test Estimate control parameters Go back CONTROL DYNAMICS: Fast, small OS Without overshoot Go back SHOW FLUID: Thermal fluid: M90 Min. working temperature: [°C]: -90 Characteristics: (zero) 27

Compact menu<br />

Control parameters: The default setting is Automatic control parameter.<br />

CONFIGURATION MANUAL<br />

CONTROL PARAMETERS:<br />

Change control parameters<br />

Display control parameters<br />

Go back<br />

Control parameters<br />

KPInt. 181.3 200,0<br />

TNInt. 77.6 100,0<br />

TVInt. 0.0 0.0<br />

CONTROL PARAMETERS<br />

Internal<br />

Cascade jacket control<br />

Cascade process<br />

Go back<br />

Control and Ident. param.<br />

KPInt. 181.3 TtInt. 1.4<br />

TNInt. 77.6 TIInt. 7033.2<br />

TVInt. 0.0 KSInt 0.00<br />

SELECT THERMAL FLUID:<br />

No specification<br />

M120.08.02<br />

M90.200.02 (DW-Therm)<br />

M90.055.03 (Sil. oil)<br />

M40.165.10 (Sil.oil)<br />

FILLING QUANTITY:<br />

Please enter the approx. thermal<br />

fluid filling capacity<br />

Temperature control in a bath…<br />

…<br />

CONTROL PARAMETERS:<br />

Select auto./ <strong>manual</strong><br />

Config. automatic<br />

Config. <strong>manual</strong> param.<br />

Reset control parameters<br />

Display Parameter<br />

Return to main menu<br />

Select auto./ <strong>manual</strong><br />

Automatic control parameters<br />

AUTOMATIC CONFIGURATION:<br />

Find control parameters<br />

Control dynamics<br />

Display control parameters<br />

Fluid properties<br />

Go back<br />

THERMAL FLUID:<br />

Thermal fluid<br />

Circulation volume<br />

Bypass usage<br />

Show fluid<br />

Go back<br />

BYPASS:<br />

If there is a partial short cut<br />

through a bypass, please choose<br />

“yes”.<br />

AUTOMATIC / MANUAL<br />

SELECTION:<br />

Manual control parameters<br />

Automatic control parameters<br />

Go back<br />

AUTOMATIC MODE:<br />

Fast identification<br />

With preliminary test<br />

Estimate control parameters<br />

Go back<br />

CONTROL DYNAMICS:<br />

Fast, small OS<br />

Without overshoot<br />

Go back<br />

SHOW FLUID:<br />

Thermal fluid: M90<br />

Min. working temperature: [°C]:<br />

-90<br />

Characteristics: (zero)<br />

27