Operating manual 27.09.2011 CC Heating Thermostats - HUBER
Operating manual 27.09.2011 CC Heating Thermostats - HUBER Operating manual 27.09.2011 CC Heating Thermostats - HUBER
Main menu The following functions are available: Compact menu Comfort menu Control parameters Acoustic alarm Comfort menu Auto-Start Display modes Clock Enter program Com.G@te (with connected Com.G@te only) Overtemperature protection Compact menu Pump settings Compressor automatic (not valid for all units) Set-point Control parameters Set-point limits Display functions Start & stop Display modes Start ramp E-Grade packages Temperature control mode Enter program User menu - select Factory default Exit Language Limits Overtemperature protection (for units with heating) Program start&stop Protection functions Pump settings Sensor adjustment Service Set-point Set-point limits Settings (others) Software version Start & stop Start ramp Temperature control mode Temperature scale Time scale User menu - config. User menu - select 2nd set-point Web.G@te (with connected Web.G@te only) Exit The individual functions are described in the following pages: 26
Compact menu Control parameters: The default setting is Automatic control parameter. CONFIGURATION MANUAL CONTROL PARAMETERS: Change control parameters Display control parameters Go back Control parameters KPInt. 181.3 200,0 TNInt. 77.6 100,0 TVInt. 0.0 0.0 CONTROL PARAMETERS Internal Cascade jacket control Cascade process Go back Control and Ident. param. KPInt. 181.3 TtInt. 1.4 TNInt. 77.6 TIInt. 7033.2 TVInt. 0.0 KSInt 0.00 SELECT THERMAL FLUID: No specification M120.08.02 M90.200.02 (DW-Therm) M90.055.03 (Sil. oil) M40.165.10 (Sil.oil) FILLING QUANTITY: Please enter the approx. thermal fluid filling capacity Temperature control in a bath… … CONTROL PARAMETERS: Select auto./ manual Config. automatic Config. manual param. Reset control parameters Display Parameter Return to main menu Select auto./ manual Automatic control parameters AUTOMATIC CONFIGURATION: Find control parameters Control dynamics Display control parameters Fluid properties Go back THERMAL FLUID: Thermal fluid Circulation volume Bypass usage Show fluid Go back BYPASS: If there is a partial short cut through a bypass, please choose “yes”. AUTOMATIC / MANUAL SELECTION: Manual control parameters Automatic control parameters Go back AUTOMATIC MODE: Fast identification With preliminary test Estimate control parameters Go back CONTROL DYNAMICS: Fast, small OS Without overshoot Go back SHOW FLUID: Thermal fluid: M90 Min. working temperature: [°C]: -90 Characteristics: (zero) 27
- Page 1 and 2: Valid for: Operating manual CC 27.0
- Page 3 and 4: Filling and air purging an external
- Page 5 and 6: Quick guide for CC-thermostats Chec
- Page 7 and 8: Chapter 1: Safety In this chapter i
- Page 9 and 10: Intended Use and General Safety Ins
- Page 11 and 12: Duties of responsible person The op
- Page 13 and 14: To 1. Temperature control machines
- Page 15 and 16: Operating conditions Please make su
- Page 17 and 18: Chapter 2: Electronics and operatio
- Page 19 and 20: Information Displays CC The followi
- Page 21 and 22: Field 10: Display delta T This fiel
- Page 23 and 24: Operation CC Please note, there are
- Page 25: CC Operation using the simulated Nu
- Page 29 and 30: 2. With preliminary Test: To achiev
- Page 31 and 32: Example: Indication when choosing L
- Page 33 and 34: To create a new program, continue a
- Page 35 and 36: Comfort menu Acoustic alarm Here yo
- Page 37 and 38: Enter program A description on this
- Page 39 and 40: Warning time level As low-level pro
- Page 41 and 42: Time scale The time display can be
- Page 43 and 44: Analogue Interface AIF INPUT FUNCTI
- Page 45 and 46: Settings: 1. Settings on temperatur
- Page 47 and 48: POCO alarm Pot. free Contact (POCO)
- Page 49 and 50: Function Numbers and their meaning
- Page 51 and 52: F30 Set date Setting the date. F31
- Page 53 and 54: F90 Language / Sprache Selecting th
- Page 55 and 56: User menu - config. Using this main
- Page 57 and 58: Chapter 3: Connect the machine, fil
- Page 59 and 60: Counter cooling (valid for CC Heati
- Page 61 and 62: Switching on the temperature contro
- Page 63 and 64: Setting the safety value: Select th
- Page 65 and 66: Ending CC Temperature control The t
- Page 67 and 68: Draining the machine and an externa
- Page 69 and 70: Interface modules (RS232/SERIAL, Co
- Page 71 and 72: The following interfaces are availa
- Page 73 and 74: RS232 / RS485 Serial Socket A PC, P
- Page 75 and 76: Pin Designation 1 Level Test (Bridg
Compact menu<br />
Control parameters: The default setting is Automatic control parameter.<br />
CONFIGURATION MANUAL<br />
CONTROL PARAMETERS:<br />
Change control parameters<br />
Display control parameters<br />
Go back<br />
Control parameters<br />
KPInt. 181.3 200,0<br />
TNInt. 77.6 100,0<br />
TVInt. 0.0 0.0<br />
CONTROL PARAMETERS<br />
Internal<br />
Cascade jacket control<br />
Cascade process<br />
Go back<br />
Control and Ident. param.<br />
KPInt. 181.3 TtInt. 1.4<br />
TNInt. 77.6 TIInt. 7033.2<br />
TVInt. 0.0 KSInt 0.00<br />
SELECT THERMAL FLUID:<br />
No specification<br />
M120.08.02<br />
M90.200.02 (DW-Therm)<br />
M90.055.03 (Sil. oil)<br />
M40.165.10 (Sil.oil)<br />
FILLING QUANTITY:<br />
Please enter the approx. thermal<br />
fluid filling capacity<br />
Temperature control in a bath…<br />
…<br />
CONTROL PARAMETERS:<br />
Select auto./ <strong>manual</strong><br />
Config. automatic<br />
Config. <strong>manual</strong> param.<br />
Reset control parameters<br />
Display Parameter<br />
Return to main menu<br />
Select auto./ <strong>manual</strong><br />
Automatic control parameters<br />
AUTOMATIC CONFIGURATION:<br />
Find control parameters<br />
Control dynamics<br />
Display control parameters<br />
Fluid properties<br />
Go back<br />
THERMAL FLUID:<br />
Thermal fluid<br />
Circulation volume<br />
Bypass usage<br />
Show fluid<br />
Go back<br />
BYPASS:<br />
If there is a partial short cut<br />
through a bypass, please choose<br />
“yes”.<br />
AUTOMATIC / MANUAL<br />
SELECTION:<br />
Manual control parameters<br />
Automatic control parameters<br />
Go back<br />
AUTOMATIC MODE:<br />
Fast identification<br />
With preliminary test<br />
Estimate control parameters<br />
Go back<br />
CONTROL DYNAMICS:<br />
Fast, small OS<br />
Without overshoot<br />
Go back<br />
SHOW FLUID:<br />
Thermal fluid: M90<br />
Min. working temperature: [°C]:<br />
-90<br />
Characteristics: (zero)<br />
27