CONCERTINA FOIL BATTS TM - SUB-FLOOR<br />

QUICK AND EASY TO INSTALL<br />

EASY TO RETROFIT<br />

Total R-value of the structure (R T ) is the sum of all component R-values, including the internal airspaces and the surface air films<br />

on either side of the structure. NB: Framing timbers are excluded from the Total R-value (R T ), as per AS/NZS 4859.1:2002.<br />

SUB - FLOOR - <strong>SmartFrame</strong> JOISTS<br />

ENCLOSED BUILDING PERIMETER<br />

SFREBP-1<br />

SUB - FLOOR - SmartJOIST<br />

ENCLOSED BUILDING PERIMETER<br />

SFREBP-2<br />

Brick veneer walls and/or close weave shade cloth behind base boards.<br />

Brick veneer walls and/or close weave shade cloth behind base boards.<br />

Perforated CONCERTINA FOIL BATT<br />

for floors - Over-lapped and stapled<br />

MIN 90 mm<br />

depth <strong>SmartFrame</strong><br />

LVL floor joists<br />

Perforated CONCERTINA FOIL BATT<br />

for floors - Over-lapped and stapled<br />

<strong>SmartFrame</strong><br />

SJ200 & SJ240<br />

I-Joists<br />

Non ventilated<br />

air-space MIN 90 mm<br />

Non ventilated<br />

air-space 90 mm<br />

Non -<br />

ventilated<br />

air-space<br />

(still air)<br />

soil<br />

<strong>SmartFrame</strong> LVL bearer<br />

Stumps<br />

WINTER R T<br />

R T 3.0*<br />

SUMMER<br />

R T 1.5<br />

Non ventilated<br />

air-space<br />

(still air)<br />

soil<br />

Stumps<br />

WINTER<br />

R T 3.0*<br />

SUMMER<br />

R T 1.5<br />

Adapted from Wren Industries Pty Ltd.- TF1 from WREN DD-1<br />

To view WREN DD-1 see www.concertinafoilbatts.com<br />

LINK Thermal Performance<br />

Adapted from Wren Industries Pty Ltd.- TF1 from WREN DD-1<br />

To view WREN DD-1 see www.concertinafoilbatts.com<br />

LINK Thermal Performance<br />

SUSPENDED FLOOR - RED ALERT JOISTS<br />

OPEN BUILDING PERIMETER WITH<br />

CLOSED JOIST CAVITIES<br />

SFROBP-1<br />

SUSPENDED FLOOR - SmartJoist<br />

- OPEN BUILDING PERIMETER<br />

WITH CLOSED JOIST CAVITIES<br />

SFROBP-2<br />

Perforated CONCERTINA FOIL BATT<br />

for floors - Over-lapped and stapled<br />

Non ventilated 50 mm<br />

Non ventilated 50 mm<br />

Ventilated sub-floor air-space<br />

Continuous lining material to create a<br />

still air joist cavity (with small gaps or<br />

perforation holes for drainage and breathing)<br />

Examples - standard RFL roll foil - foil<br />

side down or fibre cement sheet<br />

Minimum of 100 mm<br />

depth <strong>SmartFrame</strong><br />

LVL floor joists<br />

WINTER<br />

R T 2.8*<br />

SUMMER<br />

R T 1.2<br />

Perforated CONCERTINA FOIL BATT<br />

for floors - Over-lapped and stapled<br />

Non ventilated<br />

air-space 100 mm<br />

Non ventilated<br />

air-space<br />

Ventilated sub-floor air-space<br />

Continuous lining material to create a<br />

still air joist cavity (with small gaps or<br />

perforation holes for drainage and breathing)<br />

Examples - standard RFL roll foil - foil<br />

side down or fibre cement sheet<br />

<strong>SmartFrame</strong><br />

SJ200 & SJ240<br />

I-Joists<br />

WINTER<br />

R T 2.8 *<br />

SUMMER<br />

R T 1.2<br />

Adapted from Wren Industries Pty Ltd.- TF2 from WREN DD-1<br />

To view WREN DD-1 see www.concertinafoilbatts.com<br />

LINK Thermal Performance<br />

Adapted from Wren Industries Pty Ltd.- TF2 from WREN DD-1<br />

To view WREN DD-1 see www.concertinafoilbatts.com<br />

LINK Thermal Performance<br />

* R T value is dependent upon depth of non-ventilated airspace. For R T values for alternative joist depths, contact Wren Industries Pty Ltd<br />

Perforated CONCERTINA FOIL<br />

BATTS TM allow moisture<br />

drainage and maximum<br />

breathing of timber flooring,<br />

and combined with still<br />

airspaces, produce high and<br />

consistent thermal<br />

performance, reflecting 97%<br />

of radiant heat back to the<br />

floor.<br />

FOIL BATTS do not absorb<br />

or retain heat and therefore<br />

do not create warm cosy<br />

nesting environments for<br />

rodents or pests.<br />

“BREATHING” AIRSPACES<br />

ALLOWS GLUEING OF SHEETING<br />

<strong>SmartFrame</strong> Sub-floor Design Guide 7