<strong>ETC</strong> ®<br />

G e n e r a l I n f o r m a t I o n<br />

the <strong>Sensor</strong>+ <strong>Control</strong> electronics module (Cem+) receives and<br />

manages ethernet control signals as well as two DmX512 inputs. It<br />

controls dimmer output, and communicates feedback information to<br />

compatible lighting control devices and network peripherals.<br />

APPLICATIONS<br />

• Professional and educational theatre<br />

• Production studios<br />

• Performance halls<br />

• retail and dining<br />

• Houses of worship<br />

• High density architectural dimming<br />

• touring and Portable dimming<br />

FEATURES<br />

• Direct ethernet connectivity for dimmer levels, feedback and<br />

system control<br />

• two DmX512 input connections<br />

• rugged industrial construction<br />

• modular design<br />

• local menu-driven User Interface<br />

• two operating modes: Standard and Basic/Portable mode<br />

• 128 Presets with programmable fade times<br />

• System and rack feedback standard<br />

• Support for advanced features (af) dimmer-specific reporting<br />

• Supports etC Dimmer Doubling <br />

ACCESSORIES<br />

• <strong>Sensor</strong>+ Connect – a browser-based Graphical User Interface<br />

– accessible thru any server or computer on the network<br />

• DimStat – monitoring software<br />

• Smartlink ® Stations<br />

• Smartlink timeClock<br />

• retrofit kits to upgrade existing <strong>Sensor</strong> racks to Cem+<br />

modules<br />

1 of 4<br />

<strong>CEM+</strong> <strong>Control</strong> Module<br />

o r D e r I n G I n f o r m a t I o n<br />

<strong>Control</strong> Module<br />

<strong>Sensor</strong>+ Series<br />

MOdEL dESCRIPTION<br />

Cem+ <strong>Sensor</strong>+ <strong>Control</strong> electronics module<br />

Compatible Systems<br />

MOdEL dESCRIPTION<br />

SENSOR+ INSTALLATION RACkS<br />

Sr48+/Sr48af+ <strong>Sensor</strong>+ 48 module Installation racks<br />

Sr24+/Sr24af+ <strong>Sensor</strong>+ 24 module Installation racks<br />

Sr12+/Sr12af+ <strong>Sensor</strong>+ 12 module Installation racks<br />

Sr6+/Sr6af+ <strong>Sensor</strong>+ 6 module Installation racks<br />

HSr+/HSraf+ <strong>Sensor</strong>+ 230V Installation racks<br />

Srafn+ <strong>Sensor</strong>+ GfCI Installation racks<br />

SrD2+ <strong>Sensor</strong>+ Delta Installation racks<br />

eSrafn+ <strong>Sensor</strong>+ Ce Installation racks<br />

SENSOR+ TOURINg RACkS<br />

SP48+ <strong>Sensor</strong>+ 48 module touring rack<br />

SP24+ <strong>Sensor</strong>+ 24 module touring rack<br />

SENSOR+ PORTAbLE PACkS<br />

SP12+ <strong>Sensor</strong>+ 12 module Portable pack<br />

SP6+ <strong>Sensor</strong>+ 6 module Portable pack<br />

<strong>CEM+</strong> Accessories<br />

MOdEL dESCRIPTION<br />

SS-10005/10 Smartlink 5 or 10 Button Station<br />

rK and rK-af retrofit kit for <strong>Sensor</strong> standard and af racks


<strong>ETC</strong><br />

S P e C I f I C a t I o n S<br />

gENERAL<br />

• Universal <strong>Control</strong> electronics module<br />

• Direct ethernet connectivity for dimmer levels, feedback and<br />

system control<br />

• Ul, cUl lISteD and Ce marked<br />

PHYSICAL<br />

• formed steel body finished with textured epoxy paint<br />

• Injection molded face panel<br />

• Slide-in module installs and removes without tools<br />

• Spring-loaded module release<br />

• airflow sensor to ensure adequate airflow<br />

ELECTRICAL<br />

• accepts:<br />

- Single phase<br />

- three phase WYe or Delta<br />

• Universal Voltage range 91-139V and 181-265 VaC*<br />

• line feed frequencies from 47-63Hz<br />

• automatic frequency variation compensation<br />

*note: Suggested max main transformer tap 135V or 260V to<br />

allow for line fluxuation.<br />

CONTROL FEATURES<br />

• 2-line by 20-character backlit lCD for system configuration,<br />

status display and error indication<br />

• Backlit 7-button keypad includes reset button<br />

• 4 status leD indicators: Power, network activity, DmX-a<br />

and DmX-B<br />

• two configurable DmX512 inputs (2500V opto-isolated)<br />

• 128 user-programmable presets assignable to 4 rooms<br />

• maximum of 1024 racks (64 groups of 16)<br />

• Single Panic circuit with flexible programming<br />

• Individual Cem+ failure does not disable multi-rack group<br />

• replacement Cem+ can download configuration from<br />

adjacent racks, rack back plane or online server<br />

• multi-rack configuration can be restored from a single Cem+<br />

• Dimmer outputs are regulated to maintain constant power to<br />

loads ±1V<br />

• Individual output scale voltage settings for load wiring<br />

compensation (60 – 140V)<br />

• Selectable Dimmer modes: normal, Dimmer Doubled,<br />

Switched (unregulated on/off with adjustable threshold),<br />

fluorescent with adjustable threshold, always on, off<br />

• Selectable Dimmer output Curves: linear, modified linear,<br />

Square, modified Square, and <strong>Sensor</strong> 2.0<br />

• 16-Bit fade resolution option<br />

• over 30,000-Step resolution per half cycle<br />

• response speed


<strong>ETC</strong><br />

P H Y S I C a l<br />

<strong>CEM+</strong> dimensions<br />

MOdEL HEIgHT WIdTH dEPTH<br />

inches mm inches mm inches mm<br />

Cem+ 2.06 52 11.80 300 7.00 178<br />

t Y P I C a l n e t W o r K r I S e r<br />

Eos Console<br />

11.80”<br />

300mm<br />

PC for <strong>ETC</strong> software<br />

Net3 DMX Gateway<br />

DMX from<br />

external source<br />

Switch<br />

7.00”<br />

178mm<br />

2.06”<br />

52mm<br />

Unison <strong>Control</strong> Stations<br />

3 of 4<br />

<strong>CEM+</strong> Weight<br />

Radio Focus<br />

Remote<br />

(Receiver)<br />

<strong>CEM+</strong> <strong>Control</strong> Module<br />

Link Power<br />

Aux Power<br />

Link Power<br />

Eos Remote Video Interface<br />

Net3 DMX Gateway<br />

DMX<br />

CMEi in<br />

ER4 Rack<br />

To moving lights<br />

or any DMX device<br />

<strong>Sensor</strong>+ Series<br />

MOdEL WEIgHT SHIPPINg WEIgHT<br />

lbs kgs lbs kgs<br />

Cem+ 4.2 2 6.2 2.8<br />

Maximum bTU Production per module<br />

MOdEL bTUS WATTS EFFICIENCY<br />

all Cem+


<strong>ETC</strong><br />

S e n S o r + C o n n e C t<br />

<strong>Sensor</strong>+ Connect duplicates the functions of the <strong>Control</strong> electronics<br />

module (Cem+), but on a network server or computer. this graphical<br />

user interface (GUI) allows you to monitor rack activity, reconfigure<br />

dimmer curves, record or activate presets – plus a whole lot more.<br />

offers all the features needed to create, edit and download specific<br />

information to the racks and modules.<br />

FEATURES<br />

• Configure rack and module information<br />

• Patch/address 2 DmX Universes<br />

• file transfer capabilities<br />

• record and activate 128 preset looks<br />

• assign presets to up to 4 rooms<br />

SYSTEM REQUIREMENTS<br />

• network computer<br />

• Internet Browser Software such as Internet explorer 6.0<br />

or better<br />

• network connection (wired or wireless) to a <strong>Sensor</strong>+ System<br />

with a Cem+ module<br />

NAvIgATION FEATURES<br />

• Security level passwords determine screens and modes<br />

available to user<br />

• System Summary – rack status, active Presets, error list<br />

• form style application for rack name and type, address mode,<br />

temperature alarm, Power Balance – Column, Single Phase or<br />

three Phase, fan time mode<br />

• easy searches for dimmer(s) by specifying a number of search<br />

criteria – quick dimmer configuration<br />

• table style format for dimmer configuration – name and<br />

module type, dimmer mode, dimmer curve, Scale Voltage<br />

and threshold levels, Voltage regulation, Preheat, DC output<br />

Prevention, and Inrush Protection<br />

• Quick format for assigning dimmers to rooms, playing and<br />

recording presets, setting fade times and priority levels<br />

• Simple menu selections for Panic attributes<br />

• Patch table includes Port enable, DmX loss Behavior, Dimmer<br />

number Start, length, Priority, fade and Hold time.<br />

• network Setup and basic system wide commands such as<br />

dimmer check and setting a dimmer level<br />

4 of 4<br />

D I m S t a t <br />

<strong>CEM+</strong> <strong>Control</strong> Module<br />

<strong>Sensor</strong>+ Series<br />

DimStat is a comprehensive and user-friendly tool for error<br />

reporting and configuration of etC and IeS Dimming Systems.<br />

DimStat software takes the functions of these dimming systems to<br />

the next level, adding logging of feedback, text messaging, and<br />

quick exchange of show settings to the host of features that the<br />

control modules already support. DimStat, like <strong>Sensor</strong>+ Connect,<br />

offers all the features needed to create, edit and download specific<br />

information to the racks and modules.<br />

FEATURES<br />

• Configure Cem+ Systems online and offline<br />

• error and Status reporting<br />

• easy Patch/address of DmX, eDmX, saCn<br />

• file transfer capabilities<br />

SYSTEM REQUIREMENTS<br />

• Pentium 533mhz PC computer, 64mB of ram, 5mB of free<br />

hard drive space, XGa monitor (1024x768 resolution or<br />

above), Windows 2000 or XP Professional<br />

• network connection (wired or wireless) to a <strong>Sensor</strong>+ System<br />

with a Cem+ module<br />

CURRENT FUNCTIONS<br />

• optional password protections<br />

• System Status – overview of rack and system errors<br />

• monitor a rack to look at level, status, voltage, etc.<br />

• “find” an individaul channel to quickly get information<br />

• table style format for dimmer configuration – name and<br />

module type, dimmer mode, dimmer curve, Scale Voltage<br />

and threshold levels, Voltage regulation, Preheat, DC output<br />

Prevention, and Inrush Protection<br />

• Patch table includes Port enable, DmX loss Behavior, Dimmer<br />

number Start, length, Priority, fade and Hold time.<br />

• network Setup and basic system wide commands such as<br />

dimmer check and setting a dimmer level<br />

• full load recording and load reporting features for <strong>Sensor</strong>+<br />

advanced features systems<br />

• “no load”quick check<br />

• load file upload/download – load data stored per show.<br />

• error and status reporting via e-mail, SmS (text message)<br />

• Preset and panic configuration and control<br />

Corporate Headquarters • 3031 Pleasant View rd, Po Box 620979, middleton WI 53562 0979 USa • tel +1 608 831 4116 • fax +1 608 836 1736<br />

London, Uk • Unit 26-28, Victoria Industrial estate, Victoria road, london W3 6UU, UK • tel +44 (0)20 8896 1000 • fax +44 (0)20 8896 2000<br />

Rome, IT • Via ennio Quirino Visconti, 11, 00193 rome, Italy • tel +39 (06) 32 111 683 • fax +44 (0) 20 8752 8486<br />

Holzkirchen, dE • ohmstrasse 3, 83607 Holzkirchen, Germany • tel +49 (80 24) 47 00-0 • fax +49 (80 24) 47 00-3 00<br />

Hong kong • room 1801, 18/f, tower 1 Phase 1, enterprise Square, 9 Sheung Yuet road, Kowloon Bay, Kowloon, Hong Kong • tel +852 2799 1220 • fax +852 2799 9325<br />

Web • www.etcconnect.com • Copyright©2008 etC. all rights reserved. all product information and specifications subject to change. 7150l1001 rev. e Printed in USa 02/10<br />

<strong>Sensor</strong> ® products protected by one or more of the following U.S. Patent numbers 5,323,088, 5,352,088, 7,233,112, 7,019,469, 6,849,943, and 6,002,563; european number 0603333t2; German 69203609.

Hooray! Your file is uploaded and ready to be published.