Catalogue HY17-8546/UK<br />

System connection<br />

<strong>Directional</strong> <strong>Control</strong> <strong>Valve</strong>s<br />

<strong>P70</strong><br />

Below are a few examples of how the <strong>P70</strong> can be connected up.<br />

A. Power beyond connection, multi-valve system,<br />

<strong>P70</strong>CF only<br />

The pump is connected to the first valve. Flow that is not directed<br />

to a consumer via the first valve continues to the next valve. The<br />

first valve therefore has priority, i.e. in the event of full spool actuation<br />

in the first valve, no flow continues to the next valve.<br />

Inlet section Spool section End section<br />

S-function*<br />

If an additional pump is connected to valve 2, then valve 2<br />

receives the flow from pump 2 plus any residual flow from valve 1.<br />

S-function*<br />

B. Power beyond connection, single-valve system,<br />

<strong>P70</strong>CF only<br />

The pump is connected to the inlet section. Flow that is not<br />

directed out to consumers connected before the mid-inlet section<br />

continues to consumers connected after the mid-inlet section.<br />

This means that the first spool sections have priority, i.e. in the<br />

event of full spool actuation in a section before the mid-inlet<br />

section, no flow continues to the sections after the mid-inlet<br />

section.<br />

Mid-inlet section<br />

If an additional pump is connected to the mid-inlet section, then<br />

subsequent sections will receive the flow from pump 2 plus any<br />

flow from pump 1 that has not been used by the sections before<br />

the mid-inlet section.<br />

Mid-inlet section<br />

= Alternative connection<br />

= Signal line<br />

* The different functions are described in more detail on<br />

pages 14 - 21.<br />

<br />

Parker Hannifin<br />

Mobile <strong>Control</strong>s Division Europe<br />

Borås, Sweden