Catalogue HY17-8546/UK<br />
System connection<br />
<strong>Directional</strong> <strong>Control</strong> <strong>Valve</strong>s<br />
<strong>P70</strong><br />
Below are a few examples of how the <strong>P70</strong> can be connected up.<br />
A. Power beyond connection, multi-valve system,<br />
<strong>P70</strong>CF only<br />
The pump is connected to the first valve. Flow that is not directed<br />
to a consumer via the first valve continues to the next valve. The<br />
first valve therefore has priority, i.e. in the event of full spool actuation<br />
in the first valve, no flow continues to the next valve.<br />
Inlet section Spool section End section<br />
S-function*<br />
If an additional pump is connected to valve 2, then valve 2<br />
receives the flow from pump 2 plus any residual flow from valve 1.<br />
S-function*<br />
B. Power beyond connection, single-valve system,<br />
<strong>P70</strong>CF only<br />
The pump is connected to the inlet section. Flow that is not<br />
directed out to consumers connected before the mid-inlet section<br />
continues to consumers connected after the mid-inlet section.<br />
This means that the first spool sections have priority, i.e. in the<br />
event of full spool actuation in a section before the mid-inlet<br />
section, no flow continues to the sections after the mid-inlet<br />
section.<br />
Mid-inlet section<br />
If an additional pump is connected to the mid-inlet section, then<br />
subsequent sections will receive the flow from pump 2 plus any<br />
flow from pump 1 that has not been used by the sections before<br />
the mid-inlet section.<br />
Mid-inlet section<br />
= Alternative connection<br />
= Signal line<br />
* The different functions are described in more detail on<br />
pages 14 - 21.<br />
<br />
Parker Hannifin<br />
Mobile <strong>Control</strong>s Division Europe<br />
Borås, Sweden