Catalogue HY17-8546/UK<br />
Inlet Section<br />
<strong>Directional</strong> <strong>Control</strong> <strong>Valve</strong>s<br />
<strong>P70</strong><br />
Tank connection, T2 [25]<br />
Pump connection, P2 [27]<br />
Parallel connection, L [27]<br />
Main pressure relief<br />
valve [16]<br />
Pump connection,<br />
P1 [26]<br />
Standard inlet section<br />
The inlet section comes in two basic versions: the standard<br />
version and a version with pump unloading.<br />
The standard inlet section has two pump connections, P1 and<br />
P2, and a tank connection T2. The inlet section also contains the<br />
pilot-operated main pressure relief valve, in which either the UL<br />
connection for external pump unloading or the multi-level pressure<br />
relief function are located (see page 17).<br />
The <strong>P70</strong> with closed centre (<strong>P70</strong>CP) is created by combining<br />
inlet I with L or CUI at item [27]. <strong>P70</strong>LS shall always use the<br />
L option at item [27]. The difference between the <strong>P70</strong>CP and<br />
<strong>P70</strong>CF is that, in the <strong>P70</strong>CP, the open centre is used to break a<br />
hydraulic signal rather than to convey unused pump flow to tank.<br />
<strong>P70</strong>LS is using the open centre gallery for the load signal from<br />
the work port to the variable pump.<br />
Type of inlet section [15]<br />
I<br />
IU<br />
Standard inlet.<br />
Inlet with integrated pump-unloading function<br />
(<strong>P70</strong>CF only).<br />
P2<br />
P2<br />
P1B<br />
P1<br />
UL<br />
T2<br />
T2<br />
Standard inlet I without main<br />
pressure relief valve (<strong>P70</strong>CF).<br />
Standard inlet I with L-function<br />
and main pressure-relief function<br />
PS (<strong>P70</strong>CP, <strong>P70</strong>LS).<br />
14 Parker Hannifin<br />
Mobile <strong>Control</strong>s Division Europe<br />
Borås, Sweden