Indication, monitoring and system control outputs<br />

<strong>Earth</strong>-<strong>Rite</strong> RTR<br />

®<br />

<br />

Technical Specification<br />

and Certification Data<br />

Mechanical Installation Data<br />

5.5" (140 mm)<br />

<strong>Newson</strong><br />

<strong>Gale</strong><br />

Ø 0.3" (7 mm)<br />

5.5 “ (140 mm)<br />

3" (75 mm)<br />

2.2" (57 mm)<br />

7.5" (192 mm)<br />

5.2" (132 mm)<br />

ATEX certified / UL Approved copper free cast<br />

aluminium enclosure - IP 66 / NEMA 4X, 7 & 9<br />

1.8" (45 mm)<br />

2 x Tungsten<br />

Carbide Tips<br />

Stainless Steel<br />

Handles (304)<br />

Retractable<br />

Hytrel Cable<br />

2.7" (68 mm)<br />

3.15" (80 mm)<br />

Simple Apparatus GRP clamp<br />

stowage box with grounding<br />

clamp stowage pin<br />

Universal<br />

Grip<br />

237mm<br />

ATEX certified / FM Approved 2 Pole stainless steel<br />

grounding clamp fitted with one pair of tungsten carbide tips<br />

IECEx<br />

SIL 2<br />

www.newson-gale.com<br />

Turn Over


<strong>Earth</strong>-<strong>Rite</strong> RTR<br />

®<br />

<br />

Electrical and Certification Data<br />

Monitoring Unit<br />

Power Supply<br />

Power Rating<br />

Ambient Temperature Range<br />

Ingress Protection<br />

Weight<br />

Construction<br />

Hazardous Location Approvals (CSA)<br />

USA / Canada Approvals<br />

USA Approvals<br />

Canada Approvals<br />

Monitoring Circuit<br />

Operational Series Ground Resistance<br />

Output Relay Contact Rating<br />

Cable Entries<br />

Junction Box/Stowage Point<br />

Enclosure Material<br />

Terminals<br />

Stowage Device<br />

Cable Entries<br />

Clamp Cable Connection<br />

Grounding Clamp<br />

Clamp Design<br />

Body<br />

Spiral Cable<br />

Cable<br />

Conductors<br />

Length<br />

110/120V or 220/240V AC, 50-60 Hz<br />

12V or 24V DC<br />

10 watt<br />

o o o o<br />

-25 C to +55 C / -13 F to + F<br />

NEMA 4X, 7, 9 (IP 66)<br />

9.9 lbs (4.5 kg) nett<br />

Copper-free cast aluminium<br />

131<br />

Class I, Div. 1, Groups A, B, C, D<br />

Class II, Div. 1, Groups E, F, G<br />

Class III<br />

Class I, Zone 1, AEx d(ia) IIC T4,<br />

Class II, Zone 21, A21, IP66, T80C<br />

Class I, Zone 1, Ex d(ia) IIC T4,<br />

DIP A21, IP66, T80C<br />

Intrinsically Safe<br />