Earth-Rite - Newson Gale
Earth-Rite - Newson Gale
Earth-Rite - Newson Gale
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Newson</strong><br />
<strong>Gale</strong><br />
Leading the way in hazardous area static control<br />
<strong>Earth</strong>-<strong>Rite</strong><br />
®<br />
Indication, monitoring and system control outputs<br />
<strong>Earth</strong>-<strong>Rite</strong> RTR<br />
®<br />
<br />
Technical Specification<br />
and Certification Data<br />
Mechanical Installation Data<br />
5.5" (140 mm)<br />
<strong>Newson</strong><br />
<strong>Gale</strong><br />
Ø 0.3" (7 mm)<br />
5.5 “ (140 mm)<br />
3" (75 mm)<br />
2.2" (57 mm)<br />
7.5" (192 mm)<br />
5.2" (132 mm)<br />
ATEX certified / UL Approved copper free cast<br />
aluminium enclosure - IP 66 / NEMA 4X, 7 & 9<br />
1.8" (45 mm)<br />
2 x Tungsten<br />
Carbide Tips<br />
Stainless Steel<br />
Handles (304)<br />
Retractable<br />
Hytrel Cable<br />
2.7" (68 mm)<br />
3.15" (80 mm)<br />
Simple Apparatus GRP clamp<br />
stowage box with grounding<br />
clamp stowage pin<br />
Universal<br />
Grip<br />
237mm<br />
ATEX certified / FM Approved 2 Pole stainless steel<br />
grounding clamp fitted with one pair of tungsten carbide tips<br />
IECEx<br />
SIL 2<br />
www.newson-gale.com<br />
Turn Over
<strong>Earth</strong>-<strong>Rite</strong> RTR<br />
®<br />
<br />
Electrical and Certification Data<br />
Monitoring Unit<br />
Power Supply<br />
Power Rating<br />
Ambient Temperature Range<br />
Ingress Protection<br />
Weight<br />
Construction<br />
Hazardous Location Approvals (CSA)<br />
USA / Canada Approvals<br />
USA Approvals<br />
Canada Approvals<br />
Monitoring Circuit<br />
Operational Series Ground Resistance<br />
Output Relay Contact Rating<br />
Cable Entries<br />
Junction Box/Stowage Point<br />
Enclosure Material<br />
Terminals<br />
Stowage Device<br />
Cable Entries<br />
Clamp Cable Connection<br />
Grounding Clamp<br />
Clamp Design<br />
Body<br />
Spiral Cable<br />
Cable<br />
Conductors<br />
Length<br />
110/120V or 220/240V AC, 50-60 Hz<br />
12V or 24V DC<br />
10 watt<br />
o o o o<br />
-25 C to +55 C / -13 F to + F<br />
NEMA 4X, 7, 9 (IP 66)<br />
9.9 lbs (4.5 kg) nett<br />
Copper-free cast aluminium<br />
131<br />
Class I, Div. 1, Groups A, B, C, D<br />
Class II, Div. 1, Groups E, F, G<br />
Class III<br />
Class I, Zone 1, AEx d(ia) IIC T4,<br />
Class II, Zone 21, A21, IP66, T80C<br />
Class I, Zone 1, Ex d(ia) IIC T4,<br />
DIP A21, IP66, T80C<br />
Intrinsically Safe<br />
Nominally