MANUAL MANIFOLDS<br />
Section 2<br />
2.2 .......Manifolds - Adjustment<br />
The manifolds are a sealed assembly and do not have any<br />
serviceable parts or internal adjustments, however the height to<br />
which the front clamp assembly tightens up is adjustable.<br />
The clamp assembly is set, so that the manifolds are not tight<br />
against the loading table, and thus do not push down on the feed<br />
bed and affect the height of the vacuum roller.<br />
The clamp assembly is set so that when tight, the manifold has<br />
0.5mm of vertical movement when pushed down-ward against the<br />
clamp spring, at the front end.<br />
This adjustment is obtained by altering the length of the front<br />
clamp assembly which consists of two socket set screws tightened<br />
together within the knob.<br />
The short clamp screw, (inside the knob) is released using a 3mm<br />
allen key through the hole in the end of the knob. Adjust the long<br />
(protruding) clamp screw as required and re-tighten the short<br />
clamp screw inside the knob.<br />
SYSTEMS PAGE 9