Section 20<br />

TROUBLE-SHOOTING<br />

SERVICE<br />

illuminated. If not, raise the feed bed and clean the reflector<br />

and the eyes on the sensor with a brush. If the reflector and<br />

sensor eyes are very dirty, use a cloth moistened with<br />

water.<br />

2. Check the sensor connector at the rear of the control box is<br />

secure.<br />

3. Check that the sensor alignment by referring to section 7.4.<br />

4. If the green light under the counter display fails to illuminate<br />

after realignment, change the control box or counter board<br />

if available.<br />

20.1 .....Electric Delivery - Not Running<br />

1. Check that the lead is plugged into the socket on the rear<br />

panel.<br />

2. Check the fuse by removing the electric delivery control<br />

box.<br />

3. Check the fuse FS2 (2.0 amp) on the main control box.<br />

4. Check the electric delivery motor brushes.<br />

5. If fuse keeps blowing, check that the catch plate at the end<br />

of the delivery is not fouling on the cord roller .<br />

6. Make sure that the screws which hold the catch plates are<br />

not loose and preventing the cord roller from rotating.<br />

7. Check the voltage at the motor plug on the underside of the<br />

delivery bed. It should be 20 to 200 VDC depending on the<br />

position of the speed control knob. If its incorrect, replace<br />

the PCB if available, or the electric delivery control box.<br />

8. Finally, replace the motor.<br />

PAGE 58<br />