MANUAL<br />
TROUBLE-SHOOTING<br />
Section 19<br />
6. Check all wiring connections, especially on the mains<br />
cables<br />
Note ........ Always let the compressor reach full speed Before<br />
starting the motors.<br />
19.7 .....Rollers Not Turning - Feed Working<br />
1. Turn the handwheel on the drive side of machine. If the<br />
rollers will not turn, remove operator side cover and check<br />
the transmission. If all the gears and their grub screws are<br />
intact, remove drive side cover and check the main pulley.<br />
2. If the rollers turn when the handwheel is turned, check the<br />
fuse for motor 1 (#FS4 - 3.15 amp) on the main control box.<br />
3. If the fuse blows again, disconnect the motor terminals and<br />
replace the fuse. If the fuse blows repeatedly, replace the<br />
control box.<br />
4. Check connections on the motor and choke and<br />
connections at the back of the control box.<br />
5. Set motor speed to 12 o'clock and check voltage at motor<br />
which should read approx l00v.<br />
6. If no voltage, re check connections on control box. If ok<br />
change control box.<br />
19.8 .....Counter Not Working<br />
The counter operates by means of a sensor housed under the feed<br />
bed in front of the paper gate, and a reflector that is attached to<br />
the paper gate tie bar. The counter sees ( reflects ) the gaps<br />
between the sheets so therefore accurate counting cannot be<br />
achieved on stream feed. If the counter is erratic or fails to function<br />
when feeding in ‘auto’, check the following.<br />
1. Look to see if the green light under the counter display is<br />
SYSTEMS PAGE 57