Section 19<br />

TROUBLE-SHOOTING<br />

SERVICE<br />

1. Check both motor fuses - F 3 = 2.0 Amp & F 4 = 3.15 Amp<br />

2. Replace control box<br />

19.5 .....No Air - Motors Running -<br />

1. Check compressor control fuse - F 5 on control box =<br />

200mA.<br />

2. Check the mains supply to the compressor. The<br />

compressor start contactor is housed inside the rear<br />

electrical panel. Check across pins 1Ll and 5L3 which<br />

should be at mains supply voltage.<br />

3. Check that the pins in the connector inside the roof of the<br />

base unit are clean, and there are no signs of sparking, or<br />

replace as required.<br />

4. Unbolt the compressor and remove it from the machine.<br />

Inspect and replace the complete unit if necessary.<br />

19.6 .....Loss of Power when Starting Compressor<br />

1. Ensure that an extension cable is not being used causing a<br />

drop in voltage. Due to the relatively high current required<br />

to start the compressor, the mains cable supplied should<br />

not be extended in any way<br />

2. Check the main fuse in the plug or distribution board.<br />

3. Check the main isolator switch on the rear panel.<br />

4. Check filters are not clogged and change them frequently.<br />

Cleaning has only a short term effect.<br />

WARNING<br />

EXPENSIVE DAMAGE WILL OCCUR IF THE<br />

COMPRESSOR IS ALLOWED TO RUN WITHOUT ITS<br />

FILTERS.<br />

5. Check customers supply voltage and if necessary fit a<br />

Voltage Boosting Transformer of sufficient output level.<br />

PAGE 56<br />