MANUAL<br />

CROSS-FOLD UNIT<br />

Section 18<br />

18.2 .....Motor Speed Board - Continued<br />

To set the minimum motor speed, turn the front panel speed<br />

control to minimum and connect a volt meter (set to read up to 50V<br />

dc) across the red and black supply cables to the motor. Adjust the<br />

Low speed pre-set to read 25V dc .<br />

To set the maximum motor speed, turn the front panel speed<br />

control to maximum and connect a volt meter (set to read up to<br />

200V dc) across the red and black supply cables to the motor.<br />

Adjust the High speed pre-set to read 170V dc .<br />

Note ........ Take care when working with high voltages.<br />

Current Limit Set to 2.0 amps with Motor<br />

IR Compensation Set to Min. (Anti-Clockwise)<br />

Maximum Speed<br />

Set to 170 V/dc<br />

Minimum Speed<br />

Set to 25 V/dc<br />

Tangs<br />

PCB Supports<br />

Terminal Block<br />

(See Circuit Diagram for Connection Details)<br />

Control Box<br />

Circuit Board - Motor Speed ......................................Fig 18.21<br />