MANUAL ELECTRIC DELIVERY Section 16<br />
Low Speed Pre-set<br />
Motor Speed PCB<br />
Enclosure<br />
High Speed Pre-set<br />
Terminal Block<br />
Electric Delivery Control Box .....................................Fig 16.11<br />
16.1 .....Electric Delivery - Speed<br />
The electric delivery speed range should be set to suitable levels<br />
by adjusting the high and low pre-sets on the PCB. This speed<br />
range is voltage dependant and will therefore vary according to the<br />
supply voltage.<br />
WARNING.<br />
HIGH VOLTAGE ON THESE PRE-SETS, GIVING RISK OF<br />
ELECTRIC SHOCK. USE INSULATED TOOL OR<br />
DISCONNECT FROM MAINS BEFORE ADJUSTING<br />
17.1 .....Swing-up Perforating Unit - Removal<br />
The swing-up unit is removed from the machine as a unit by<br />
releasing the two M10 nuts. Both shoulder bushes are then pulled<br />
inwards and removed.<br />
The M10 bolt on the operator side is then pulled outwards and the<br />
swing-up unit is removed.<br />
SYSTEMS PAGE 45