Section 12<br />

FOLD PLATES<br />

SERVICE<br />

Locking Screw<br />

Adjusting Screw<br />

Upper Rail<br />

Jacking Screw<br />

Lower Rail<br />

Fold Plate - Lower Rail Adjustment .............................Fig 12.11<br />

12.1 .....Fold Plate - Lower Rail Adjustment<br />

Plate Shown Up-side Down<br />

The fold plate lower rail on each fold plate may be adjusted to<br />

reduce the gap between the upper and lower rails or may be<br />

moved closer to, or further away from, the fold rollers.<br />

If heavy stock sticks in the fold plate without folding ( providing the<br />

rollers are set correctly ) this may indicate that the lower rail has<br />

been set too close to the fold rollers.<br />

If light stock does not enter the fold plate, has a very small fold, or<br />

damage to the lead edge, this may indicate that the lower rail has<br />

been set too far away from the fold rollers.<br />