4<br />

Thermal <strong>energy</strong> <strong>metering</strong> – GE555 user modules<br />

GE555 – VERSIONS WITH VOLUMETRIC METER FOR THERMAL ENERGY.<br />

User modules for the handling of the heating and conditioning in centralized <strong>system</strong>s having zone distribution. The components are installed inside painted<br />

sheet cabinets, available in two different dimensions. They have a 3-way motorized zone valve having a 24V~ or 230V~ motor. All units have regulation of<br />

the third way (balancing only By-pass); a balancing valve permits to effect the capacity regulation for the house (static balancing); an automatic regulation<br />

of the capacity (dynamic balancing) is possible in coupling with a differential by-pass. The units can be used either for heating or for conditioning due to the<br />

double register <strong>energy</strong> counters (to be ordered separately). Possibility of horizontal or vertical installation of the cabinet and possibility of unit positioning<br />

with flow direction from left to right, or from right to left (in this case the unit and the collars shall be repositioned at customer’s care). Guides are present in<br />

the cabinets to lodge from one to three units dedicated to sanitary water.<br />

Cabinet dimensions:<br />

See following table<br />

To complete GE555 module, it is possible to order separately:<br />

- GE552 <strong>thermal</strong> <strong>energy</strong> meter<br />

- GE550 units or preassembled groups, with thermostatic mixer, to measure the consumption of hot and/or cold sanitary water and grey waters<br />

- K270 or K272 motor to drive the zone valve<br />

- Components for the data consumption centralization and remote control through M-Bus<br />

GE555 STANDARD MODULES<br />

Part numbers<br />

CABINET DIMENSIONS<br />

(B x H x P)<br />

mm<br />

CONNECTIONS<br />

BALANCING<br />

GUIDES FOR SANITARY<br />

WATER UNITS<br />

GE555Y401 500x500x145 3/4” By-pass only 2<br />

GE555Y402 600x600x145 3/4” Static 3<br />

GE555Y403 600x600x145 1” Static 3<br />

GE555Y404 600x600x145 3/4” Dynamic 3<br />

GE555Y405 600x600x145 1” Dynamic 3<br />

GE555Y401 GE555Y402 GE555Y403 GE555Y404 GE555Y405<br />

GE552 Thermal <strong>energy</strong> meters.<br />

Part numbers: GE552Y117 (volumetric 3/4” 0.6m3/h)<br />

GE552Y115 (volumetric 3/4” 1.5m3/h)<br />

GE552Y118 (volumetric 1” 2.5m3/h)<br />

GE550 units or preassembled groups for sanitary<br />

water.<br />

Units or preassembled groups for the measurement<br />

of the consumption of the hot and cold sanitary<br />

water and grey waters.<br />

K270-K272 motor for zone valve.<br />

Motor for zone valves having end stroke microswitch.<br />

Part numbers: K270Y001 (230 V~ supply)<br />

K270Y002 (24 V~ supply)<br />

K272Y001 (230 V~ supply)<br />

K272Y002 (24 V~ supply)