16 Thermal energy metering – GE556 user satellites with instantaneous SHW production GE556 USER SATELLITES. User satellites for the handling of heating and the production of sanitary hot water in centralized systems with zone distribution. On the heating delivery, it has a zone valve that can be equipped with a K270 or K272 motor (to be ordered separately). The metering of thermal energy and of the consumption of sanitary cold water is possible by means of GE552 meters (to be ordered separately). The thermal energy meter and the sanitary cold water meter are preset for the communication on M-Bus. Also available with increased plate exchanger or with an additional inlet for pre-heated water. Main features • Heating handling and sanitary cold water production • Satellite to be inserted in template (external or to be embedded) • Satellite with preset electrical wiring • 3/4” connections • Motorized zone valve, heating side • Balancing lockshield valve, heating side • Sanitary cold water production power: 44 or 58 kW • Thermostatic mixer for sanitary water • Box for electrical components • Dimensions (B x H x P): 540 x 390 x 155 mm To complete GE556 satellites, order separately: • K270 or K272 zone valve motor (24V~ or 230V~ option) • Sanitary cold and hot water meters • Components for the centralization and remote control of the consumption data through M-Bus • Templates for installation on building site - template for external (GE551Y054) - template to be embedded (GE551Y056) • Additional valve kit for template (only for GE556Y304) • Pipe kit for installation of the satellite into the template (GE551Y107) • Pipe kit for washing and pressure test (GE551Y108) GE556Y306 Main features • Heating handling function (low temperature) and sanitary hot water production • Innovative configuration with auxiliary heat exchanger supporting the heater serpentine • Electronic regulator of thermoregulation with remote control (anti arrearage function) • 100l cylinder, enamelled and insulated, with magnesium anode, 5 year guarantee • painted sheet cabinet • Satellite with preset electrical wiring • 3/4” connections • Motorized zone valve, heating side • Sanitary cold water production power: 10kW-44kW • Thermostatic mixer for sanitary water • Box for electrical components • Dimensions (B x H x P): 580 x 480 x 1610 mm To complete GE556Y306 satellites, order separately: • K270 or K272 zone valve motor (24V~ or 230V~ option) • Sanitary cold and hot water meters • Components for the centralization and remote control of the consumption data through M-Bus . PART NUMBER MAIN FUNCTIONS EXCHANGER FILTER GE556Y301 Priority valve 44kW YES GE556Y302 Priority valve 58kW YES GE556Y303 Thermostatic control and dynamic balancing 58kW YES GE556Y304 Solar thermal integration 44kW YES GE556Y305 For external heater (optional) max 58kW YES GE556Y306 Integrated 100 l cylinder 10kW-44kW YES For all versions the power of the exchanger refers to the following working conditions: - primary 75°C, capacity 1 m 3 /h - secondary 15-50°C, 18 l/min (24 l/in for GE556Y302, GE556Y303 and GE556Y305) For versions having increased exchanger (GE556Y302, GE556Y303 and GE556Y305), the power can be considered equal to 44kW to the following operation conditions: - primary 65°C, capacity 1 m 3 /h - secondary 15-50°C, 18 l/min For GE556Y306 version, 10kW value is the power of the heater serpentine; 44kW is the power of the auxiliary exchanger. GE556Y301 GE556Y302 GE556Y303 GE556Y304 GE556Y305 GE556Y306

17 Thermal energy metering – GE556 user satellites with instantaneous SHW production ACCESSORIES TO BE ORDERED SEPARATELY FOR GE556 SATELLITES GE552 Thermal energy meters. Part numbers: GE552Y115 (volumetric 3/4” 1.5m3/h) GE552Y122 (ultrasounds sing. reg. 3/4” 1.5m3/h) GE552 water meter for sanitary water. Water meter for sanitary cold and hot water with 3/4” connections and 100 mm distance between the axis. Part number: GE552Y111 (SCW water meter) GE552Y113 (SHW water meter) K270-K272 motor for zone valve. Motor for zone valves having end stroke microswitch. Part numbers: K270Y001 (230 V~ supply) K270Y002 (24 V~ supply) K272Y001 (230 V~ supply) K272Y002 (24 V~ supply) ACCESSORIES FOR GE556Y301, GE556Y3002, GE556Y303, GE556Y304 AND GE556Y305 ONLY GE551 template. Template for installation on building site including closing door with lock. Part numbers: GE551Y054 (external version) Dimensions: 550 x 680 x165 mm (B x H x P) GE551Y056 (version to be embedded) Dimensions: 570 x 770 x165 mm (B x H x P) Additional valve kit. Additional valve for the satellite with solar integration (GE556Y304). Part number: GE500Y251 GE551 connection pipe kit. Pipe kit for the satellite connection to the template. Part numbers: GE551Y107 GE551Y112 (for GE556Y304 only) GE551 washing pipe kit. Pipe kit for the washing and pressure test of the system. Part number: GE551Y108 R189 fitting with stop. Fitting with stop for the sanitary water circuit (it is possible to install two in parallel, one for the cold water and one for the hot water). Part number: R189VY004 ACCESSORIES FOR GE556Y305 SATELLITE ONLY BS1-BS2 cylinder. High efficiency cylinder with single or double serpentine to be joined to GE556Y305 satellite.

16<br />

Thermal <strong>energy</strong> <strong>metering</strong> – GE556 user satellites with instantaneous SHW production<br />

GE556 USER SATELLITES.<br />

User satellites for the handling of heating and the production of sanitary hot water in centralized <strong>system</strong>s with zone distribution. On the heating delivery,<br />

it has a zone valve that can be equipped with a K270 or K272 motor (to be ordered separately). The <strong>metering</strong> of <strong>thermal</strong> <strong>energy</strong> and of the consumption of<br />

sanitary cold water is possible by means of GE552 meters (to be ordered separately). The <strong>thermal</strong> <strong>energy</strong> meter and the sanitary cold water meter are preset<br />

for the communication on M-Bus. Also available with increased plate exchanger or with an additional inlet for pre-heated water.<br />

Main features<br />

• Heating handling and sanitary cold water production<br />

• Satellite to be inserted in template (external or to be embedded)<br />

• Satellite with preset electrical wiring<br />

• 3/4” connections<br />

• Motorized zone valve, heating side<br />

• Balancing lockshield valve, heating side<br />

• Sanitary cold water production power: 44 or 58 kW<br />

• Thermostatic mixer for sanitary water<br />

• Box for electrical components<br />

• Dimensions (B x H x P): 540 x 390 x 155 mm<br />

To complete GE556 satellites, order separately:<br />

• K270 or K272 zone valve motor (24V~ or 230V~ option)<br />

• Sanitary cold and hot water meters<br />

• Components for the centralization and remote control<br />

of the consumption data through M-Bus<br />

• Templates for installation on building site<br />

- template for external (GE551Y054)<br />

- template to be embedded (GE551Y056)<br />

• Additional valve kit for template (only for GE556Y304)<br />

• Pipe kit for installation of the satellite into the template (GE551Y107)<br />

• Pipe kit for washing and pressure test (GE551Y108)<br />

GE556Y306 Main features<br />

• Heating handling function (low temperature)<br />

and sanitary hot water production<br />

• Innovative configuration with auxiliary heat exchanger supporting<br />

the heater serpentine<br />

• Electronic regulator of thermoregulation with remote control<br />

(anti arrearage function)<br />

• 100l cylinder, enamelled and insulated, with magnesium anode,<br />

5 year guarantee<br />

• painted sheet cabinet<br />

• Satellite with preset electrical wiring<br />

• 3/4” connections<br />

• Motorized zone valve, heating side<br />

• Sanitary cold water production power: 10kW-44kW<br />

• Thermostatic mixer for sanitary water<br />

• Box for electrical components<br />

• Dimensions (B x H x P): 580 x 480 x 1610 mm<br />

To complete GE556Y306 satellites, order separately:<br />

• K270 or K272 zone valve motor (24V~ or 230V~ option)<br />

• Sanitary cold and hot water meters<br />

• Components for the centralization<br />

and remote control of the consumption data through M-Bus<br />

.<br />

PART NUMBER MAIN FUNCTIONS EXCHANGER FILTER<br />

GE556Y301 Priority valve 44kW YES<br />

GE556Y302 Priority valve 58kW YES<br />

GE556Y303 Thermostatic control and dynamic balancing 58kW YES<br />

GE556Y304 Solar <strong>thermal</strong> integration 44kW YES<br />

GE556Y305 For external heater (optional) max 58kW YES<br />

GE556Y306 Integrated 100 l cylinder 10kW-44kW YES<br />

For all versions the power of the exchanger refers to the following working conditions:<br />

- primary 75°C, capacity 1 m 3 /h<br />

- secondary 15-50°C, 18 l/min (24 l/in for GE556Y302, GE556Y303 and GE556Y305)<br />

For versions having increased exchanger (GE556Y302, GE556Y303 and GE556Y305), the power can be considered equal to 44kW to the following operation<br />

conditions:<br />

- primary 65°C, capacity 1 m 3 /h<br />

- secondary 15-50°C, 18 l/min<br />

For GE556Y306 version, 10kW value is the power of the heater serpentine; 44kW is the power of the auxiliary exchanger.<br />

GE556Y301 GE556Y302 GE556Y303 GE556Y304<br />

GE556Y305<br />

GE556Y306