2001<br />

LOW-SLOPE<br />

ROOFING<br />

MATERIALS<br />

GUIDE<br />

The information source on low-slope membranes, insulation boards, roof coatings and cements,<br />

roof fastener products and membrane warranties for the commercial roof designer, specifier,<br />

installer, manufacturers and user<br />

10255 W. Higgins Road, Suite 600<br />

Rosemont, IL 60018-5607<br />

847/29-9070<br />

FAX: 847/299-1183<br />

E-mail: nrca@nrca.net<br />

Internet: www.nrca.net


Copyright © 2001 by the <strong>National</strong> <strong>Roof</strong>ing Contrac<strong>to</strong>rs <strong>Association</strong>. No part of this publication may<br />

be reproduced or distributed in any form by any means, or s<strong>to</strong>red in a data base retrieval system,<br />

without prior written permission from the publisher.


Table of Contents<br />

Low-Slope <strong>Roof</strong>ing Materials Guide<br />

5 Introduction<br />

6 How the Guide Is Organized<br />

6 Product Listing With Incomplete Data<br />

7 General Index<br />

Section 1: <strong>Roof</strong> <strong>Coverings</strong><br />

23 Information on Low-Slope <strong>Roof</strong> Membrane Products<br />

31 Index <strong>to</strong> Listed <strong>Roof</strong> <strong>Coverings</strong><br />

44 Built-up <strong>Roof</strong>ing, Part 1: General Information<br />

74 Built-up <strong>Roof</strong>ing, Part 2: Specifications<br />

118 Modified Bitumen, Part 1: General Information<br />

172 Modified Bitumen, Part 2: Test Results<br />

264 Modified Bitumen, Part 3: Specifications<br />

292 PVC, Part 1: General Information<br />

298 PVC, Part 2: Test Results<br />

304 EPDM, Part 1: General Information<br />

316 EPDM, Part 2: Test Results<br />

326 CSPE, Part 1: General Information<br />

327 CSPE, Part 2: Test Results<br />

328 PIB, Part 1: General Information<br />

329 PIB, Part 2: Test Results<br />

330 TPO, Part 1: General Information<br />

332 TPO, Part 2: Test Results<br />

336 Other Prefabricated Sheet-Applied Membranes, Part 1: General Information<br />

342 Other Prefabricated Sheet-Applied Membranes, Part 2: Test Results<br />

352 Spray Polyurethane Foam-based Systems, Part 1: Insulation<br />

354 Spray Polyurethane Foam-based Systems, Part 2: Coatings<br />

366 Metal <strong>Roof</strong> Panels<br />

411 Manufacturers Appendix<br />

Section 2: Rigid Board Insulation<br />

419 Information on Rigid Board Insulation<br />

423 Index <strong>to</strong> Listed Rigid Board Insulation<br />

425 Cellular Glass<br />

426 Composite<br />

432 Expanded Polystyrene<br />

442 Extruded Polystyrene<br />

454 Glass Fiber<br />

456 Glass-Mat Faced Gypsum<br />

458 Perlite<br />

460 Polyisocyanurate<br />

470 Wood Fiberboard


Table of Contents<br />

474 Manufacturers Appendix<br />

Section 3: <strong>Roof</strong> Fasteners<br />

483 Information on <strong>Roof</strong> Fasteners<br />

485 Index <strong>to</strong> Listed <strong>Roof</strong> Fasteners<br />

486 <strong>Roof</strong> Fasteners: Steel Decks<br />

512 <strong>Roof</strong> Fasteners: Wood Decks<br />

544 <strong>Roof</strong> Fasteners: Concrete Decks<br />

560 <strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum, and Cementitious Wood Fiber<br />

Decks<br />

582 Manufacturers Appendix<br />

Section 4: <strong>Roof</strong> Cements & Adhesives, and Coatings<br />

587 Information on <strong>Roof</strong> Cements and Adhesives, and Coatings<br />

589 Index <strong>to</strong> Listed <strong>Roof</strong> Cements and Adhesives, and Coatings<br />

592 <strong>Roof</strong> Cements and Adhesives, and Coatings Part 1: General Information<br />

638 <strong>Roof</strong> Cements & Adhesives, Part 2: Technical Data<br />

668 <strong>Roof</strong> Coatings, Part 2: Technical Data<br />

719 Manufacturers Appendix<br />

Section 5: <strong>Roof</strong> Membrane Warranties<br />

723 Information on <strong>Roof</strong> Membrane Warranties<br />

724 Understanding the Warranty Listing<br />

730 Index <strong>to</strong> <strong>Roof</strong> Membrane Warranties<br />

734 <strong>Roof</strong> Membrane Warranties<br />

Section 6: Incomplete Data<br />

829 Index <strong>to</strong> Incomplete Data


Low-Slope <strong>Roof</strong>ing Materials Guide<br />

Introduction<br />

The 2001 edition of NRCA’s Low-Slope <strong>Roof</strong>ing<br />

Materials Guide is a comprehensive report on<br />

commercial, industrial and institutional low-slope<br />

roof covering, rigid insulation board, fastener, and<br />

cements and coating products currently on the<br />

market in the United States. It also provides<br />

pertinent information about the warranties offered<br />

for most membrane roof systems.<br />

The <strong>National</strong> <strong>Roof</strong>ing Contrac<strong>to</strong>rs <strong>Association</strong><br />

(NRCA) publishes the guide annually as a service<br />

<strong>to</strong> the roofing industry. The objective of the guide<br />

is <strong>to</strong> provide information that will be helpful <strong>to</strong><br />

users in determining which specific manufacturers’<br />

products will best serve their particular needs. It is<br />

of special value <strong>to</strong> those associated with the<br />

design, specification, application and use of lowslope<br />

roof systems.<br />

The guide’s first edition was published in 1983.<br />

From its inception until 1992, it was titled the<br />

<strong>Roof</strong>ing Materials Guide. The 1993 edition of this<br />

publication was the first one <strong>to</strong> bear the title<br />

Commercial Low-Slope <strong>Roof</strong>ing Materials Guide.<br />

The term “commercial low-slope” distinguished it<br />

from a companion publication, the Residential<br />

Steep-Slope <strong>Roof</strong>ing Materials Guide, which was<br />

first published in November 1992. The Residential<br />

Steep-Slope <strong>Roof</strong>ing Materials Guide provided<br />

information on asphalt shingle, clay and concrete<br />

tile, wood shake and shingle, fiber-cement and<br />

synthetic shingle, slate, architectural metal panel<br />

and underlayment products, and asphalt shingle<br />

warranties.<br />

When applied <strong>to</strong> the U.S. roofing market, the<br />

terms “commercial low-slope” and “residential<br />

steep-slope” are by no means definitive. Lowslope<br />

roofing products commonly are used on nonresidential<br />

buildings (e.g., commercial, industrial,<br />

and institutional buildings) and are sometimes<br />

used on residential buildings (e.g., single family<br />

homes, <strong>to</strong>wnhouses). Conversely, steep-slope<br />

roofing products are commonly used on residential<br />

buildings and are sometimes used on nonresidential<br />

buildings.<br />

Beginning in 1999, the titles of these guides<br />

changed <strong>to</strong> the Low-Slope <strong>Roof</strong>ing Materials<br />

Guide and the Steep-Slope <strong>Roof</strong>ing Materials<br />

Guide. The reason for these title changes, and<br />

division of product categories, is for consistency with<br />

other NRCA publications, including The NRCA<br />

<strong>Roof</strong>ing and Waterproofing Manual.<br />

Low-slope roofing products are those primarily<br />

intended for roofs with slopes of 3:12 (14 degrees) or<br />

less. Built-up, polymer modified bitumen, single-ply,<br />

spray polyurethane foam-based, and structural metal<br />

panel roof systems fit this category.<br />

Steep-slope roofing products are defined as those<br />

primarily intended for roofs with slopes greater than<br />

3:12 (14 degrees). Asphalt shingle, fiber-cement and<br />

synthetic, clay and concrete tile, wood shake and<br />

shingle, slate and architectural metal panel roof<br />

systems fit this category.<br />

In publishing the Low-Slope <strong>Roof</strong>ing Materials Guide,<br />

NRCA maintains a policy of objectivity in its reporting<br />

of data. Nothing is required from listing manufacturers<br />

other than <strong>to</strong> adhere <strong>to</strong> the prescribed reporting<br />

format. Any manufacturer of a product in the product<br />

categories included in the guide can be listed by<br />

submitting its information in accordance with<br />

procedures developed for this purpose. Companies<br />

involved only in the distribution of other companies’<br />

brand-name roofing products are not included in this<br />

publication. Manufacturers interested in having their<br />

products listed in future editions of the guide are<br />

encouraged <strong>to</strong> contact NRCA at:<br />

<strong>National</strong> <strong>Roof</strong>ing Contrac<strong>to</strong>rs <strong>Association</strong><br />

Attention: <strong>Roof</strong>ing Materials Guide<br />

10255 West Higgins Road, Suite 600<br />

Rosemont, Illinois 60018-5607<br />

NRCA exercises due care in accurately reporting the<br />

data supplied by product manufacturers. NRCA does<br />

not audit test procedures used <strong>to</strong> arrive at the reported<br />

data, nor assume responsibility for the accuracy or<br />

completeness of the data submitted. The presence or<br />

absence of a listing of products or manufacturers in<br />

the guide does not imply NRCA’s approval or<br />

disapproval of the products or companies, nor does<br />

NRCA recommend that any specific materials be used<br />

or not.<br />

NRCA does not develop standards itself but, instead,<br />

works <strong>to</strong>wards and supports the improvements of<br />

existing standards and development of new ones by<br />

those organizations responsible for standards<br />

development. The fact that materials listed in the<br />

guide do or do not meet all the values of the reference<br />

5


Low-Slope <strong>Roof</strong>ing Materials Guide<br />

standards, documents, recommendations or Product Listings with Incomplete Data<br />

criteria does not necessarily imply that they will or<br />

will not produce acceptable roof systems. Product manufacturers included in the guide are<br />

encouraged <strong>to</strong> provide NRCA with listing information<br />

How the Guide is Organized<br />

for their products that is as complete as possible for<br />

publication in the guide. When manufacturers submit<br />

The Low-Slope <strong>Roof</strong>ing Materials Guide is product information (e.g., test results) that is<br />

divided in<strong>to</strong> six primary sections:<br />

incomplete, these specific products have been omitted<br />

C Section 1: <strong>Roof</strong> <strong>Coverings</strong><br />

from the detailed listing sections of the guide.<br />

C Section 2: Rigid Board Insulation<br />

Manufacturers and products with incomplete product<br />

C Section 3: <strong>Roof</strong> Fasteners<br />

listing information are included in a new section of the<br />

C Section 4: <strong>Roof</strong> Cements & Adhesives, and guide, entitled Section 6: Incomplete Data.<br />

Coatings<br />

C Section 5: <strong>Roof</strong> Membrane Warranties NRCA has established this policy regarding<br />

C Section 6: Incomplete Data.<br />

manufacturers’ product listings with incomplete data at<br />

the request of users of the guide, who are clearly<br />

There is a general index listing all product seeking detailed and complete product information<br />

manufacturers included in the guide and the from the guide and the companies listed.<br />

locations of their specific product listings at the<br />

end of this introduc<strong>to</strong>ry section. Also a listing of all Users of the guide who are interested in specific<br />

product manufacturers and the locations of their product information on a manufacturer’s product that<br />

specific products is provided at the beginning of is included in Section 6: Incomplete Data are<br />

each section, with exception <strong>to</strong> Section 6: encouraged <strong>to</strong> contact the product manufacturer<br />

Incomplete Data. directly. Manufacturers’ contact information is<br />

provided in the index section of the guide.<br />

There is also an introduction <strong>to</strong> information for<br />

each section at the beginning of each section.<br />

The introduction <strong>to</strong> Section 1: <strong>Roof</strong> <strong>Coverings</strong><br />

encompasses built-up, polymer modified bitumen,<br />

single-ply, spray polyurethane foam-based and<br />

metal panel roof system products.<br />

Finally, there are separate appendices at the end<br />

of Section 1: <strong>Roof</strong> <strong>Coverings</strong>, Section 2: Rigid<br />

Board Insulation, Section 3: <strong>Roof</strong> Fasteners and<br />

Section 4: <strong>Roof</strong> Cements and Coatings. The<br />

purpose of these appendices is <strong>to</strong> provide<br />

manufacturer-supplied information that expands<br />

data listed in the category section itself. Appendix<br />

information can be found for a product when an<br />

“X” appears in the space at the end of the listing<br />

entitled “See Appendix if Checked”.<br />

When reviewing the data in the guide, users<br />

should keep in mind that the format is designed <strong>to</strong><br />

facilitate side-by-side product comparisons. For<br />

this reason, listing companies can only respond <strong>to</strong><br />

existing items of requested information; they<br />

cannot add their own items. Footnoting is not<br />

permitted in guide listings; companies instead<br />

may expand on or clarify information by providing<br />

copy for the appendix.<br />

6


General Index<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

AEP-SPAN 366<br />

P O Box 150449<br />

Dallas, TX 75315<br />

214/827-1746<br />

FAX: 214/828-1394<br />

E-mail: info@aep-span.com<br />

Web site: www.aep-span.com<br />

AFM R-CONTROL BUILDING SYS. 426 432<br />

2400 W. Highway 7, Suite 201<br />

Excelsior, MN 55331<br />

800/255-0176<br />

FAX: 952/474-2074<br />

E-mail: afm@r-control.com<br />

Web site: www.r-control.com<br />

ALCM 592 833<br />

7301 Bessemer Avenue 638<br />

Cleveland, OH 44127 668<br />

800/556-8030<br />

FAX: 216/341-5833<br />

E-mail: sales@alum.com<br />

Web:<br />

ALCO-NVC, INC. 594 833<br />

P O Box 14001 639<br />

Detroit, MI 48214 670<br />

800/323-0029<br />

FAX: 313/331-4726<br />

E-mail: alconvc@aol.com<br />

Web site: www.alconvc.com<br />

AMERICAN LUBRICANTS CO. 118 734<br />

1227 Deeds Avenue 172<br />

Day<strong>to</strong>n, OH 45401<br />

937/222-2851<br />

FAX: 937/461-7729<br />

E-mail:<br />

Web:<br />

AMERICAN STEEL BUILDING CO. 369<br />

P O Box 14244<br />

Hous<strong>to</strong>n, TX 77221<br />

800/ 872-8335 or 713/433-5661<br />

FAX: 713/433-0847<br />

E-mail: sreiners@hal-pc.org<br />

Web:<br />

AMERICAN TAR COMPANY 595<br />

A Division of Fields Company, LLC 641<br />

2240 Taylor Way 671<br />

Tacoma, WA 98421<br />

253/627-4098<br />

FAX 253/627-3859<br />

E-mail:<br />

ANDEK CORPORATION 354 597<br />

P O Box 392 641<br />

850 Glen Avenue 675<br />

Moores<strong>to</strong>wn, NJ 08057-0392<br />

888/88ANDEK (26335)<br />

FAX: 888/44ANDEK (26335)<br />

E-mail: andekcorp.@aol.com<br />

ARCHITECTURAL METAL SYSTEMS 369<br />

1150 State Docks Road<br />

Eufaula, AL 36027<br />

888/621-5020<br />

FAX: 334/687-9297<br />

E:mail: info@ametalsystems.com<br />

ARS INDUSTRIES 372<br />

9606 Parkway East, Suite E<br />

Birmingham, AL 32515<br />

205/836-6777<br />

FAX: 205/836-4090<br />

E-mail:<br />

Web:<br />

7


General Index<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

ARVRON INC. 433<br />

4720 Clay, SW<br />

Grand Rapids, MI 49548<br />

616/530-1888<br />

Fax:<br />

E-mail:<br />

Web:<br />

ATAS INTERNATIONAL, INC. 374<br />

Iron Run Industrial Park<br />

6612 Snowdrift Road<br />

Allen<strong>to</strong>wn, PA 18106<br />

610/395-8445<br />

FAX: 610/395-9342<br />

E-mail: info@atas.com<br />

ATLAS ROOFING CORP. 460<br />

1775 The Exchange, Suite 160<br />

Atlanta, GA 30339<br />

770/933-4478<br />

FAX: 770/952-3170<br />

E-mail: rrgelatka@atlasroofing.com<br />

Web site: www.atlasroofing.com<br />

BAKOR div. Of Henry Company 118<br />

284 Watline Avenue 196<br />

Mississauga, ON L4Z 1P4<br />

CANADA<br />

905/890-4800<br />

FAX: 905/890-4866<br />

Web: www.bakor.com<br />

BARRETT COMPANY 44 734<br />

3422 Old Capi<strong>to</strong>l Trail 74<br />

Wilming<strong>to</strong>n, DE 19808<br />

800/647-0100<br />

FAX: 908/647-0100<br />

E-mail:<br />

Web: www.barrettroofs.com<br />

BENCHMARK FOAM INC. 427 434<br />

3200 9th Ave., S.E.<br />

Water<strong>to</strong>wn, SD 57201-9102<br />

800/658-3444<br />

FAX: 605/886-8099<br />

E-mail: getfoam@benchmarkfoam.com<br />

Web site: www.benchmarkfoam.com<br />

BERRIDGE MANUFACTURING CO. 376<br />

<strong>Roof</strong> Division<br />

Hous<strong>to</strong>n, TX 77026<br />

713/223-4971<br />

FAX: 713/433-0847<br />

E-mail: sales@berridge.com<br />

Web site: www.berridge.com<br />

BIG SKY INSULATION INC. 435<br />

15 Arden Drive<br />

P O Box 838<br />

Belgrade, MT 59714<br />

406/388-4146<br />

FAX:<br />

E-mail:<br />

BITEC INC. 120 738<br />

#2 Industrial Park Dr. 172<br />

Morril<strong>to</strong>n, AR 72110 199<br />

800/535-8597 264<br />

FAX 501/354-3019<br />

E-mail: dga@bitec.com<br />

Web site: www.bi-tec.com<br />

BONDCOTE ROOFING SYSTEMS 336 740<br />

4090 Pepperell Way 342<br />

Dublin, VA 24084<br />

800/368-2160<br />

FAX: 540/674-6511<br />

E-mail: bcrtech@bondcote.com<br />

Web: www.bondcote.com<br />

8


General Index<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

BUTLER MANUFACTURING CO. 381<br />

BMA Tower<br />

Penn Valley Park<br />

Kansas City, MO 64141<br />

816/968-2370<br />

FAX 816/968-2371<br />

E-mail:<br />

CARLISLE SYNTEC INC 304 330 336 436 442 463 470 486 740 830<br />

P.O. Box 7000 316 332 343 512<br />

Carlisle, PA 17013 544<br />

717/245-7000 560<br />

FAX 717/245-7245<br />

E-mail:<br />

Web: www.carlislesyntec.com<br />

CELOTEX CORP. 123 305 488 742 829<br />

4010 Boy Scout Blvd. 173 317 514<br />

Tampa, FL 33607 265 545<br />

813/873-1700 562<br />

FAX: 813/873-4080<br />

E-mail: aharring<strong>to</strong>n@celotex.com<br />

Web:<br />

CERTAINTEED 46 123<br />

ROOFING PRODUCTS GROUP 76 173<br />

750 E. Swedesford Rd 203<br />

P O Box 860 266<br />

Valley Forge, PA 19482<br />

800/359-7298 FAX: 610/341-7055<br />

Web site: www.certainteed.com<br />

CONKLIN CO. 326 355 598 744<br />

P.O. Box 155 327 675<br />

Shakopee, MN 55379-0155<br />

800/888-8838<br />

FAX 952/496-4285<br />

E-mail: marketing@conklin. com<br />

Web site: www.conklin.com<br />

CONSTRUCTION FASTENERS INC. 489<br />

Dekfast Product Group 515<br />

Spring & Van Reed Box 6326 546<br />

Wyomissing, PA 19610 562<br />

610/376-5751<br />

FAX: 610/376-8551<br />

Web site: www.constructionfasteners.com<br />

COOLEY ENGINEERED 336<br />

MEMBRANE INC. 343<br />

50 Esten Avenue Box 939<br />

Pawtucket, RI 02862-0939<br />

401/724-0490<br />

FAX: 401/726-8731<br />

E-mail: cooleygroup.com<br />

CURVELINE INC. 382<br />

1745 Monticello Court<br />

Ontario, CA 91761<br />

909/947-6022<br />

FAX 909/947-1510<br />

E-mail: curveline@curveline.com<br />

Web site: www.met.tile/com/curveline<br />

DANOSA CARIBBEAN INC. 125 746<br />

Box 13757, Santurce Station 205<br />

San Juan, PR 00908-3757 267<br />

787/785-4545<br />

FAX 787/787-3902<br />

E-mail: danosapr@icepr.com<br />

Web site: www.danosapr.com<br />

DERMABIT, WATERPROOFING 126 748<br />

INDUSTRIES INC. 175<br />

P. O Box 3952 207<br />

Greenville, DE 19807-3952<br />

302/652-2740<br />

FAX: 302/652-0195<br />

E-mail:<br />

9


General Index<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

DEWITT PRODUCTS CO. 598<br />

5860 Plumer 642<br />

Detroit, MI 48209 675<br />

313/554-0575 800/962-8599<br />

FAX 313/554-2171<br />

E-mail:<br />

Web site: www.dewitt@globalbiz.com<br />

DIBITEN 127 748<br />

P.O. Box 5108 179<br />

Denver, CO 80217-5108 268<br />

800/342-4836<br />

FAX 303/978-3904<br />

E-mail:<br />

Web:<br />

DOW CHEMICAL CO., THE 445<br />

Fabricated Products Business Center<br />

1605 Joseph Drive, Larkin 200 Building<br />

Midland, MI 48674<br />

517/638-5225<br />

E-mail:<br />

Web:<br />

DOW CORNING CORPORATION 355<br />

P.O. Box 994<br />

Midland, MI 48686-0994<br />

517/496-6000<br />

FAX 517/496-8026<br />

E-mail:<br />

Web:<br />

DURO-LAST INC. 337 491 752<br />

525 Morley Drive 373 517<br />

Saginaw, MI 48601 575<br />

800/248-0280 (All U.S.) 563<br />

FAX 800/432-9331<br />

E-mail: dlsagmi.concentric.net<br />

Web: duro-last.com<br />

ECOLOGY ROOF SYSTEMS 49 127 337 600<br />

505 N. Tustin Avenue #188 79 175 344 643<br />

Santa Ana, CA 92705 208 677<br />

714/972-1001 269<br />

FAX: 714/972-1079<br />

E-mail:<br />

Web site: www.ecologyroofystems.com<br />

ENGLERT INC. 382<br />

1200 Amboy Ave.<br />

Perth Amboy, NJ 08862<br />

732/826-8614<br />

FAX 732/826-8865<br />

E-mail:<br />

Web:<br />

ERSYSTEMS 306 337 355 754<br />

Elas<strong>to</strong>meric <strong>Roof</strong>ing Systems, Inc. 318 344<br />

50 Medina Street<br />

Loret<strong>to</strong>, MN 55357-0056<br />

612/479-6690 FAX: 612/479-6691<br />

E-mail: ersinfo@ersystems.com<br />

Web site: www.ersystems.com<br />

ES PRODUCTS 517<br />

280 Franklin Street, P.O. Box 810 563<br />

Bris<strong>to</strong>l, RI 02809<br />

401/253-8600<br />

FAX: 401/253-8896<br />

E-mail:<br />

Web:<br />

FABRAL 384<br />

3449 Hempland Road<br />

Lancaster, PA 17601<br />

717/397-2741<br />

FAX 717/397-1040<br />

E-mail: fabinf@fabral.com<br />

Web:<br />

10


General Index<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

FALCON FOAM 436<br />

Division of Atlas <strong>Roof</strong>ing Corp.<br />

8240 Byron Center Road<br />

Byron Center, MI 49315<br />

616/878-1568<br />

FAX: 616/878-9942<br />

E-mail:<br />

FIELDS COMPANY, LLC 49 602<br />

2240 Taylor Way 83 644<br />

Tacoma, WA 98421 679<br />

253/627-4098<br />

FAX 253/383-2181<br />

E-mail:<br />

Web:<br />

FIRESTONE BUILDING 55 129 292 307 330 427 456 464 470 491 760<br />

PRODUCTS CO. 86 176 298 332 332 518<br />

525 Congressional Blvd. 211 548<br />

Carmel, IN 46032 270 568<br />

800/428-4442<br />

E-mail: fires<strong>to</strong>nebpco.com<br />

Web:<br />

FLEX MEMBRANE INTERNATIONAL, 292 337 762<br />

INC. 298 345<br />

Bethelem Drive<br />

Morgan<strong>to</strong>wn, PA 19543<br />

610/286-7788<br />

FAX 610/286-7786<br />

E-mail flexroof@compuserve.com<br />

FOAM ENTERPRISES, INC. 352<br />

13630 Water<strong>to</strong>wer Circle 356<br />

Minneapolis,MN 55441<br />

888/900-3626 or 763/559-9390<br />

FAX: 763/559-0945<br />

E-mail: foamnet@aol.com<br />

Web:<br />

FOLLANSBEE STEEL 389<br />

P.O. Box 610<br />

Follansbee, WV 26037<br />

800/624-6906<br />

FAX 304/527-1269<br />

E-mail: folrfg@lbcorp.com<br />

Web:<br />

GAF MATERIALS CORP. 57 131 292 330 437 447 458 465 471 493 605 762<br />

1361 Alps Road 91 177 298 332 519 647<br />

Wayne, NJ 07470 214 549 685<br />

973/628-3000 271 569<br />

800/766-3411<br />

FAX: 973/628-3451<br />

Web site: www.gaf.com<br />

GACO WESTERN, INC. 353<br />

P.O. Box 88698 357<br />

Seattle, WA 98138-2698<br />

800/456-4226<br />

FAX 206/575-0587<br />

E-mail:<br />

Web:<br />

GALVAMET, INC. 389<br />

2267 Via Bur<strong>to</strong>n Street<br />

Anaheim, CA 92806<br />

714/758-4848<br />

FAX 714/758-4855<br />

E-mail: jgeortner@galvamet.com<br />

Web:<br />

GARDNER ASPHALT CORP./APOC 358 607<br />

DIVISION 648<br />

P.O. Box 5449 686<br />

Tampa, FL 33675-5449<br />

FAX 813/248-6768<br />

E-mail:<br />

Web:<br />

11


General Index<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

GARLAND COMPANY INC. 134 390 610<br />

3800 E. 91st Street 217 651<br />

Cleveland, OH 44105 679<br />

216/641-7500<br />

FAX 216/641-0633<br />

E-mail:<br />

Web:<br />

G.E. SEALANTS & ADHESIVES 359<br />

16325 Northcross Drive<br />

Charlotte, NC 28078<br />

704/655-2022<br />

FAX: 704/655-2060<br />

E-mail:<br />

Web site:<br />

GENFLEX ROOFING SYSTEMS 293 308 330 338 792<br />

1722 Indian Wood Circle, Suite A 299 320 333 345<br />

Maumee, OH 43537<br />

800/448-4272<br />

FAX: 419/891-4436<br />

E-mail:<br />

Web site: www.genflex.com<br />

GMX, INC. 612<br />

9105 Way Ave. 692<br />

Cleveland, OH 44105<br />

216/641-7502<br />

FAX 216/641-0633<br />

E-mail:<br />

Web:<br />

G-P GYPSUM CORPORATION 456<br />

133 Peachtree St, NE<br />

Atlanta, GA 30303<br />

800/225-6119<br />

FAX: 404/230-7052<br />

E-mail:<br />

Web:<br />

HENRY COMPANY 58 137 613 770<br />

(includes Monsey Bakor, Grundy, Monsey) 96 221 653<br />

2911 Slauson Avenue 273 693<br />

Hunting<strong>to</strong>n Park, CA 90255<br />

323/583-5000<br />

FAX: 323/582-6429<br />

Web site: www.henry.com<br />

HICKMAN SYSTEMS INC., W.P. 69 168 824<br />

30700 Solon Industrial Parkway 113 184<br />

Solon, OH 44139 263<br />

440/248-7760<br />

FAX 440/248-6524<br />

E-mail: wphickman@wphickman.com<br />

Web:<br />

HONEYWELL INDUSTRIES, INC. 59 139<br />

2000 Regency Parkway, Suite 255 98 273<br />

Cary, NC 27511<br />

800/221-6490<br />

FAX: 919/461-4720<br />

E-mail:<br />

Web site:<br />

HUEBERT FIBERBOARD CO. 471<br />

1545 E. Morgan Street, Box 167<br />

Booneville, MO 65233<br />

660/882-2704<br />

FAX: 660/882-2704<br />

E-mail:<br />

Web: www.huebertfiberboard.com<br />

HYLOAD INC. 338 774<br />

9976 Rittman Road 346<br />

Wadsworth, OH 44281<br />

800/457-4056<br />

Fax: 330/336-5512<br />

E-mail:<br />

Web site:<br />

12


General Index<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

IB ROOF SYSTEMS 295<br />

2877 Chad Drive-B 300<br />

Eugene, OR 97408<br />

541/242-2871<br />

FAX: 541/302-6692<br />

E-mail: solution@ibroof.com<br />

Web:<br />

ICA, INC. 139<br />

P.O. Box 679 178<br />

Warring<strong>to</strong>n, PA 18976 275<br />

800/352-7002<br />

FAX 215/918-0890<br />

E-mail: hedgese1@aol.com<br />

Web:<br />

IKO INDUSTRIES 139<br />

120 Hay Rd. 179<br />

Wilming<strong>to</strong>n, DE 19809 226<br />

302/764-3100 276<br />

FAX 302/764-5852<br />

E-mail:<br />

Web site: iko.com<br />

INNOVATIVE METALS CO., INC. 390<br />

2070 Steel Drive<br />

Tucker, GA 30084<br />

770/908-1030<br />

FAX 770/908-2264<br />

E-mail<br />

Web:<br />

INSUL-BOARD, INC. 438<br />

2120 Colonial Ave.<br />

P.O. Box 679<br />

Erie, PA 16505<br />

814/833-7400<br />

FAX: 814/838-4774<br />

E-mail: insul@erie.net<br />

INSULATED BUILDING SYSTEMS, INC. 428 438<br />

9912 George<strong>to</strong>wn Pike, Suite D2<br />

Great Falls, VA 22066<br />

703/757-0118<br />

FAX: 703/757-0119<br />

E-mail: nicos@rcontrollbs.com<br />

Web:<br />

INTERCONTINENTAL COATINGS 339<br />

CORP, (I-CON) 348<br />

16744 W. Park Circle Drive<br />

Chagrin Falls, OH 44023<br />

440/543-3114<br />

FAX: 440/543-3443<br />

E-mail:<br />

INTERNATIONAL DIAMOND 308 776<br />

SYSTEMS INC. 320<br />

P.O. Box 351950<br />

Toledo, OH 43635<br />

419/382-0111<br />

FAX 419/382-3275<br />

E-mail: internationaldiamond@att.com<br />

IPS Insulated Panel Systems 391<br />

P . O. Box 968<br />

Stafford, TX 77497-0968<br />

281/499-2605<br />

FAX 281/499-3363<br />

E-mail:<br />

Web: www.insulated-panels.com<br />

ITW BUILDEX 495<br />

1349 W. Bryn Mawr Avenue 521<br />

Itasca, IL 60143 550<br />

800/284-5339 630/595-33500 571<br />

FAX: 630/595-6329<br />

E-mail:<br />

Web:<br />

13


General Index<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

JOHNS MANVILLE INTERNATIONAL 60 142 285 309 331 429 454 459 465 498 778<br />

<strong>Roof</strong>ing Systems Group 101 179 301 321 333 523<br />

P.O. Box 5108 229 551<br />

Denver, CO 80217 277 572<br />

303/978-2000<br />

FAX 303/978-3904<br />

E-mail:<br />

KARNAK CORPORATION 32 619<br />

330 Central Avenue 104 659<br />

Clark, NJ 07066 700<br />

732/388-0300 800/526-4236<br />

FAX 732/388-9422<br />

E-mail:<br />

Web site: www.karnakcorp.com<br />

KOKEM PRODUCTS INC. 623<br />

4432 N.E. Davis 703<br />

Portland, OR 97213<br />

503/235-9206<br />

FAX 503/235-9206<br />

E-mail:<br />

Web:<br />

KOPPERS INDUSTRIES INC. 63 145 429 459 466 471 786<br />

436 Seventh Avenue, #1650 105 181<br />

Pittsburgh, PA 15219 232<br />

800468-9629 279<br />

FAX: 412/227-2002<br />

E-mail:<br />

Web site: www.koppers.com<br />

MALARKEY ROOFING CO. 64 146 790<br />

P.O. Box 17217 108 181<br />

Portland, OR 97217-0217 233<br />

503/283-1191 OR 800/545-1191 280<br />

E-mail:<br />

Web:<br />

MBCI/NCI 392<br />

P.O. Box 38217<br />

Hous<strong>to</strong>n, TX 77238<br />

281/445-8555<br />

FAX 281/445-1791<br />

E-mail www.mbci.com<br />

Web:<br />

MCELROY METAL CO. 396<br />

1500 Hamil<strong>to</strong>n Road<br />

Bossier City, LA 71111<br />

318/747-8000<br />

FAX 318/747-8029<br />

E-mail:<br />

Web:<br />

MERCHANT & EVANS INC. 399<br />

100 Connecticut Drive<br />

Burling<strong>to</strong>n, NJ 08016<br />

609/387-3033<br />

FAX 609/387-4838<br />

E-mail:<br />

Web:<br />

METACRYLICS ACRYLIC 623<br />

POLYESTER ROOFING PRODUCT 661<br />

142 N. 27th Street 703<br />

San Jose, CA 95116<br />

408/280-7733<br />

FAX 408/280-6329<br />

Web site: www.metacrylics.com<br />

METAL SALES MFG CORP 401<br />

7800 State Rd. 60<br />

Sellersburg, IN 47172<br />

812/246-0819<br />

FAX 812/246-0829<br />

E-mail: pserv@aye.net<br />

Web site: www.mtlsales.com<br />

14


General Index<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

MFM BUILDING PRODUCTS 65<br />

P.O. Box 340 109<br />

520 Orange St.<br />

Coshoc<strong>to</strong>n, OH 43812<br />

7404/622-2645 800/882-7663<br />

E-mail: mfm@coshoc<strong>to</strong>n.com<br />

Web:<br />

MULE HIDE PRODUCTS CO., INC. 296 310 326 791<br />

2924 Wyetta Drive 301 322 327<br />

Beloit, WI 53511<br />

608/365-3111<br />

FAX: 608/365-7852<br />

E-mail:<br />

Web:<br />

NATIONAL COATINGS CORP. 359<br />

1201 Calle Suerte<br />

Camarillo, CA 93012<br />

805/388-7112<br />

FAX 805/388-8140<br />

E-mail: nationalcoatings.com<br />

Web:<br />

NATIONAL NAIL CORP. 524<br />

2964 Clydon, SW 551<br />

Grand Rapids, MI 49509<br />

800/746-5659<br />

FAX: 616/531-5970<br />

E-mail:<br />

Web:<br />

NEOGARD, DIV JONES BLAIR 359 625<br />

6900 Maple Avenue P.O. Box 35288 705<br />

Dallas, TX 75235<br />

800/321-6588<br />

FAX 214/357-7532<br />

E-mail: neogard@neogard.org<br />

Web:<br />

NORTH CAROLINA FOAM IND. 353<br />

1515 Carter St. P.O. Box 1528<br />

Mount Airy, NC 27030<br />

336/789-9161<br />

FAX 336/789-9586<br />

E-mail: rogerm@ncfi.com<br />

Web site: www.ncfi.com<br />

OLYMPIC FASTENERS 499<br />

P.O. Box 508 526<br />

153 Bowles Road 552<br />

Agawam, MI 01001 573<br />

800/633-3800 413/789-0252<br />

FAX: 413/789-1069<br />

E-mail: info@olyfast.com<br />

OMNOVA SOLUTIONS 792<br />

GenFlex <strong>Roof</strong>ing Systems<br />

1722 Indian Wood Circle, Suite A<br />

Maumee, OH<br />

419/891-4470<br />

FAX: 419/891-4436<br />

E-mail: mike.fenner@omnova.com<br />

Web:<br />

OWENS CORNING 448<br />

275 Southwest Avenue<br />

Tallmadge, OH 44278<br />

330/633-6735<br />

E-mail:<br />

Web<br />

PACEMAKER PLASTICS CO., INC. 429 439<br />

126 New Pace Road, P. O. Box 279<br />

Newcomers<strong>to</strong>wn, OH 43832<br />

800/446-2188<br />

FAX: 740/498-4184<br />

E-mail: pacemaker@tusco.net<br />

Web site: www.pacemakerplastics.com<br />

15


General Index<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

PACTIV BUILDING PRODUCTS 453<br />

2100 RiverEdge Parkway, Suite 175<br />

Atlanta, GA 30328<br />

800/241-4402<br />

FAX:<br />

E-mail:<br />

Web: www.pactivbuilding products.com<br />

PERFORMANCE ROOF SYSTEMS 147 792<br />

4821 Chelsea Ave. 181<br />

Kansas City, MO 64130 282<br />

816/921-0221<br />

FAX 816/921-5540<br />

E-mail: prshunt@aol.com<br />

Web:<br />

PETERSEN ALUMINUM 402<br />

1005 Tonne Rd.<br />

Elk Grove Village, IL 60007<br />

800/323-1960<br />

FAX 800/722-7150<br />

E-mail:<br />

www.pac-clad.com<br />

PITTSBURGH CORNING CORP. 425<br />

800 Presque Isle Drive<br />

Pittsburg, PA 15239<br />

800/359-8433<br />

FAX: 724/327-5890<br />

E-mail:<br />

Web site: www.foamglasinsulation.com<br />

PLASTIC COATINGS CORP. 360<br />

P.O. Box 1068<br />

St. Albans, WV 25177<br />

304/755-9151<br />

FAX 304/755-0229<br />

E-mail:<br />

Web:<br />

PLYMOUTH FOAM INC. 441<br />

1800 Sunset Drive<br />

Plymouth, WI 53073<br />

920/893-0535<br />

FAX: 920/892-4986<br />

E-mail:<br />

Web site: www.plymouthfoam.com<br />

POLY FOAM INC. 441<br />

116 Pine Street, South<br />

Lester Prairie, MN 55354-0218<br />

320/395-2551<br />

E-mail:<br />

Web:<br />

POLYGLASS USA 148<br />

150 Lyon Drive 183<br />

Fernley, NV 89408 234<br />

702/575-6007 283<br />

FAX 702/575-2314<br />

E-mail: cus<strong>to</strong>merservice@polyglass.com<br />

Web: www.polyglass.com<br />

POWERS RAWL, 502<br />

Powers Fasteners, Inc. 527<br />

New Rochelle, NY 10801 553<br />

914/235-6300 575<br />

FAX: 914/576-6483<br />

E-mail:<br />

Web:<br />

PROTECTIVE COATINGS INC. 311 796<br />

1602 Birchwood Avenue 323<br />

Fort Wayne, IN 46803<br />

219/424-2900 800/992-8299<br />

FAX: 219/422-7147<br />

E-mail:<br />

Web:<br />

16


General Index<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

QUANTUM COATING 361<br />

9200 Latty Avenue<br />

St. Louis, MO 63042<br />

800/624-4995<br />

FAX: 314/524-6522<br />

E-mail:<br />

Web:<br />

R-MAX INC. 430 467<br />

13524 Welch Road<br />

Dallas, TX 75244<br />

972/387-4500<br />

FAX: 972/387-4673<br />

E-mail:<br />

Web site: www.rminc.com<br />

REPUBLIC POWDERED METALS, INC. 328 625 796 831<br />

3735 Green Road 329 705<br />

Beachwood, OH 44122<br />

800/551-7081<br />

FAX: 888/742-1759<br />

E-mail:<br />

Web:<br />

ROOFING PRODUCTS 312 798<br />

INTERNATIONAL 324<br />

57460 Dewitt St.<br />

Elkhart, IN 46517<br />

800/628-2957 219/293-9096<br />

FAX 219/294-3450<br />

E-mail:<br />

Web site: www.roofingproductsint.com<br />

SARNAFIL INC. 296 800<br />

100 Dan Road 302<br />

Can<strong>to</strong>n, MA 02021<br />

800/451-2504 or 781/828-5400<br />

FAX: 781/828-3528<br />

E-mail: webmaster@sarnafil.com<br />

Web site: sarnafilus.com<br />

SEAMAN CORPORATION 341 800<br />

FiberTite <strong>Roof</strong>ing Systems by Seaman 350<br />

1000 Venture Blvd.<br />

Wooster, OH 44691<br />

800/927-8578<br />

FAX: 800/649-2737<br />

Web site: www.fibertite.com<br />

SENCO PRODUCTS 529<br />

8485 Broadwell Road<br />

Cincinnati, OH 45244<br />

800/543-4596<br />

FAX: 800/543-3299<br />

E-mail:<br />

Web site: www.senco.com<br />

SFS STADLER INC. 503<br />

5460 Wegman Drive 530<br />

Valley City, OH 44280 55<br />

330/273-7171 800/648-6032 576<br />

FAX: 330/273-7181<br />

E-mail:<br />

Web:<br />

SIMPLEX NAILS & FASTENERS, INC. 533<br />

100 Petty Road, Suite A 556<br />

Lawrenceville, GA 30043-4813 578<br />

800/622-3354<br />

FAX: 770/822-6822<br />

E-mail: technical@www.simplexnails.com<br />

Web:<br />

SIPLAST INC. 151 804<br />

1111 Hwy. 67 South 236<br />

Arkadelphia, AR 71923 284<br />

870/246-8094<br />

FAX: 870/246-3696<br />

E-mail: tkersey@siplast.com<br />

Web:<br />

17


General Index<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

SOMAY PRODUCTS, INC. 625<br />

4301 N.W. 35th Avenue 707<br />

Miami, FL 33142-4382<br />

305/633-6333 or 888/24-somay<br />

FAX 305/638-5524<br />

E-mail: paint@somay.com<br />

Web: www.somay.com<br />

SOPREMA, INC. 153 806<br />

310 Quadral Drive 241<br />

Wadsworth, OH 44281<br />

330/334-0066 800/356-3521<br />

FAX 330/334-4289<br />

E-mail:<br />

Web:<br />

SOUTHWESTERN PETROLEUM 66 158 626 806<br />

CORPORATION (SWEPCO) 111 187 662<br />

534 No. Main St. P.O. Box 961005 285 707<br />

Fort Worth, TX 76161-0005<br />

817/332-2336 800/877-9372<br />

FAX 817/877-4047<br />

E-mail: swepcousa.com<br />

SPM THERMO-SHIELD INC. 628<br />

Rt. 2, Box 208A 710<br />

Custer, SD 57730<br />

605/673-3201<br />

FAX 605/673-3200<br />

E-mail: spm@thermoshield.com<br />

Web:<br />

STEELOX ROOF SYSTEMS 405<br />

P.O. Box 8181<br />

Mason, OH 45040-8181<br />

513/573-5200<br />

FAX 513/573-5511<br />

E-mail: tab.colbert@steelox.com<br />

Web:<br />

STEVENS ROOFING SYSTEMS 326 331<br />

J.P.S. Elas<strong>to</strong>merics Corp. 327 334<br />

9 Sullivan Road<br />

Holyoke, MA 01040-2800<br />

800/621-ROOF<br />

FAX 413/552-1198<br />

E-mail: info@stvroof.com<br />

SUNGUARD MARKETING CORP. 628<br />

4432 N.E. Davis 710<br />

Portland, OR 97213<br />

503/235-9206<br />

FAX 503/235-9206<br />

E-mail:<br />

Web:<br />

SWD URETHANE COMPANY 353<br />

222 South Date St. 363<br />

Mesa, AZ 85210<br />

480/969-8413 800/828-1394<br />

FAX 480/461-6926<br />

E-mail: whip@swdurethane.com<br />

Web site: www.swdurethane.com<br />

T-CLEAR CORPORATION 430<br />

P. O. Box 416<br />

Hamil<strong>to</strong>n, OH 45012<br />

800/544-7398 or 513/870-9243<br />

FAX: 513/870-9606<br />

E-mail: telesouth1.com<br />

Web:<br />

TAMKO ROOFING PRODUCTS, INC. 67 158 628 808<br />

220 West 4th Street PO Box 1404 111 249 663<br />

Joplin, MO 64802 285 711<br />

417/624-6644<br />

FAX 417/624-8935<br />

E-mail:<br />

Web site: www.tamko.com<br />

18


General Index<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

TEMPLE 472<br />

P O Drawer N<br />

Diboll, TX 75941<br />

936/829-1254 800/231-6060<br />

FAX: 800/426-7382<br />

E-mail: gkeeling@temple.com<br />

Web site: www.temple.com<br />

TEXAS REFINERY CORP. 159 812<br />

One Refinery Place P.O. Box 711 187<br />

Ft. Worth, TX 76101 287<br />

817/332-1161<br />

FAX 817/332-2340<br />

E-mail:<br />

Web site: www.texasrefinery.com<br />

TEXSA, S.A. 160<br />

Poligono Can Pelegri 187<br />

San Andreu de la Barca, Spain 250<br />

34-3-6820770 287<br />

FAX 34-3-6820752<br />

E-mail:<br />

Web:<br />

TOPCOAT, INC., A SUBSIDIARY 630<br />

OF GAF MATERIALS CORP. 711<br />

1361 Alps Road<br />

Wayne, NJ 07470<br />

800/766-3411 or 873/628-3000<br />

FAX: 973/628-3451<br />

Web site: www.gaf.com<br />

TREMCO INC. 68 166 326 467 473 508 632 814<br />

3735 Green Rd. 112 257 327 579 665<br />

P.O. Box 228069 328 714<br />

Beachwood, OH 44122-8069 329<br />

216/292-5000<br />

FAX: 216/766-5629<br />

Web site: www.tremcoroofing.com<br />

TRU-FAST CORPORATION 509<br />

02105 William County Road 12-C 541<br />

Bryan, OH 43506 557<br />

800/443-9602 580<br />

FAX: 419/636-1784<br />

E-mail: tru-fast@bright.net<br />

Web site: trufast.com<br />

UNITED COATINGS 363 635<br />

19011 E Cataldo 717<br />

Greenacres, WA 99016<br />

509/926-7143<br />

FAX 509/928-1116<br />

E-mail: info@unitedcoatings<br />

Web: www.unitedcoatings.com<br />

UNITED STEEL DECK INC. 407<br />

475 Springfield Avenue<br />

P.O. Box 662<br />

Summit, NJ 07902-0662<br />

908/277-1617<br />

FAX 908/277-1619<br />

E-mail: heagler@ix.netcom.com<br />

U.S. INTEC INC. 167 468 542 816<br />

1361 Alps Road 193 559<br />

Wayne, NJ 07470 259 581<br />

800/624-6832 287<br />

FAX: 973/628-4167<br />

E-mail:<br />

Web site: www.usintec.com<br />

VERSICO INCORPORATED 313 341 822<br />

3485 Fortuna Drive 325 351<br />

Akron, OH 44312<br />

330/644-6700 800/992-7663<br />

FAX 330/644-2613<br />

E-mail:<br />

Web:<br />

19


General Index<br />

EXTRUDED INSULATION<br />

EPS INSULATION<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

METAL<br />

GLASS-MAT FACED GYPSUM<br />

BOARD<br />

INCOMPLETE DATA<br />

MEMBRANE WARRANTIES<br />

ROOF CEMENTS & ADHESIVE,<br />

AND COATINGS<br />

ROOF FASTENERS<br />

WOOD FIBERBOARD INSULATION<br />

POLYISOCYANURATE<br />

INSULATION<br />

PERLITE INSULATION<br />

OTHER PRE-FABRICATED<br />

GLASS FIBER INSULATION<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

SPF BASED SYSTEMS<br />

CSPE/PIB<br />

EPDM<br />

PVC<br />

TPO<br />

VINCENT METAL GOODS 409<br />

P.O. Box 360<br />

Minneapolis, MN 55440<br />

763/717-9000<br />

FAX 763/717-7122<br />

E-mail:<br />

Web: www.vincentmetalgoods.com<br />

W P HICKMAN SYSTEMS INC. 69 168 824<br />

30700 Solon Industrial Parkway 113 193<br />

Solon, OH 44139 259<br />

440/248-7760<br />

FAX 440/248-6524<br />

E-mail: wphickman@wphickman.com<br />

Web: www.wphickman.com<br />

20


Section 1<br />

<strong>Roof</strong> <strong>Coverings</strong>


Information on Section 1: <strong>Roof</strong> <strong>Coverings</strong><br />

General Information 6. Manufacturers plant locations<br />

7. Method of distribution<br />

Section 1: <strong>Roof</strong> <strong>Coverings</strong> in the 2001 edition of 8. Number of regional locations<br />

NRCA’s Low-Slope <strong>Roof</strong>ing Materials Guide is divided 9. Licensed applica<strong>to</strong>r agreement<br />

in<strong>to</strong> 10 primary sections based on roof covering 10. Sales information contact<br />

product type. These primary sections are as follows: 11. Technical information contact<br />

C Built-up membrane 12. See appendix<br />

C Modified bitumen sheet membrane<br />

C PVC single-ply membrane Reporting of compliance data in Item 4 is based upon<br />

C EPDM single-ply membrane the following American Society for Testing and<br />

C CSPE single-ply membrane Materials (ASTM) standards:<br />

C PIB single-ply membrane<br />

C TPO single-ply membrane Base Sheets:<br />

C Other prefabricated single-ply membranes • ASTM D4601, titled “Standard Specification for<br />

C Spray polyurethane foam-based Asphalt-Coated Glass Fiber Base Sheet Used in<br />

C Metal panels <strong>Roof</strong>ing”<br />

• ASTM D4897, titled “Standard Specification for<br />

A specific description of each particular roof covering Asphalt-Coated Glass-Fiber Venting Base Sheet<br />

type and a general description of the specific Used in <strong>Roof</strong>ing”<br />

information contained within each primary section are • ASTM D2626, titled “Standard Specification for<br />

included at the conclusion of this General Information Asphalt-Saturated and Coated Organice Felt<br />

section.<br />

Base Sheet Used in <strong>Roof</strong>ing”<br />

Ply Sheets:<br />

An index of the manufacturers included in Section 1: • ASTM D2178, titled “ Standard Specification for<br />

<strong>Roof</strong> <strong>Coverings</strong> and locations of their specific Asphalt Glass Felt Used in <strong>Roof</strong>ing and<br />

products within this section immediately follows this Waterproofing”<br />

<strong>Roof</strong> <strong>Coverings</strong> section. • ASTM D4990, titled “Standard Specification for<br />

Built-Up Membrane •<br />

Coal Tar Glass Felt Used in <strong>Roof</strong>ing and<br />

Waterproofing”<br />

ASTM D226, titled “ Standard Specification for<br />

A built-up roof membrane is defined in The NRCA<br />

Asphalt-Saturated Oragnic Felt Used in <strong>Roof</strong>ing<br />

and Waterproofing”<br />

<strong>Roof</strong>ing and Waterproofing Manual, Fifth Edition as • ASTM D227, titled “ Standard Specification for<br />

“a continuous, semi-flexible roof membrane, Coal-Tar-Saturated Organic Felt Used in<br />

consisting of plies of saturated felts, coated felts, <strong>Roof</strong>ing and Waterproofing”<br />

fabrics or mats assembled in place with alternate • ASTM D1668, titled “Standard Specification for<br />

layers of bitumen and surfaced with mineral Glass Fabrics (Woven and Treated) for <strong>Roof</strong>ing<br />

aggregate, bituminous materials, a liquid-applied and Waterproofing”<br />

coating or a granule-surfaced cap sheet.” • ASTM D5665, titled “Standard Specification for<br />

Information on built-up roofs is presented in the guide<br />

Thermoplastic Fabrics Used in Cold-Applied<br />

<strong>Roof</strong>ing and Waterproofing”<br />

in two parts: Part 1: General Information, Part 2: • ASTM D5726, titled “Standard Specification for<br />

Specifications.<br />

Thermoplastic Fabrice Used in Hot-Applied<br />

<strong>Roof</strong>ing and Waterproofing”<br />

Specific listing information included in part 1: General Cap Sheets:<br />

Information is as follows: • ASTM D249, titled “Standard Specification for<br />

Asphalt Roll <strong>Roof</strong>ing (Organic Felt) Saturated<br />

1. Company name with Mineral Granules”<br />

2. Product name • ASTM D371, titled “Standard Specification for<br />

3. Product description Asphalt Roll <strong>Roof</strong>ing (Organic Felt) Surfaced<br />

4. Complies with (ASTM standard designation) with Mineral Granules; Wide Selvage”<br />

5. Product width<br />

23


• ASTM D3909, titled “Standard Specification for Information on modified bitumen sheet products is<br />

Asphalt Roll <strong>Roof</strong>ing (Glass Felt) Surfaced With presented in the guide in three parts: Part 1: General<br />

Mineral Granules”<br />

Information, Part 2: Test Results and Part 3: Modified<br />

Bitumen Specifications. Part 2: Test Results is further<br />

In Part 2: Specifications, manufacturers listing divided in<strong>to</strong> two sections based upon polymer modifier<br />

information is provided based upon the following: type, APP Modified Bitumen Part 2: Test Results and<br />

SBS Modified Bitumen Part 2: Test Results.<br />

1. Company name<br />

2. Specification number legend Specific listing information included in Part 1: General<br />

3. Specification number Information is as follows:<br />

4. Hot and/or cold applied 1. Company name<br />

5. Deck type 2. Product name<br />

6. Slope requirement 3. Product description<br />

7. Number of plies 4. Kinds of field surfacing required<br />

8. Type of ply sheet 5. Use in<br />

9. Interply adhesive 6. Field joint lap method<br />

10. Surfacing 7. Types of roof systems<br />

11. Flashing materials/method 8. Minimum slope required<br />

12. Weight 9. Acceptable substrates<br />

13. Restricted regions 10. Restricted regions<br />

14. Test results 11. Workable temperature range<br />

15. See appendix 12. Flashing material<br />

13. Flashing method<br />

Reporting of test result data in Item 14: Test Results 14. Preformed accessories available<br />

per NBS BSS #55 is on the basis of the <strong>National</strong> 15. Country of origin and manufacture<br />

Bureau of Standards (NBS) Building Science Series 16. Year of first commercial use<br />

(BSS) #55, titled “Preliminary Criteria for Bituminous 17. Number of squares installed<br />

Membrane <strong>Roof</strong>ing”, dated 1974. 18. Methods of distribution<br />

19. Number of regional locations<br />

Warranty information for built-up membrane roof 20. Licensed applica<strong>to</strong>r agreement<br />

systems is provided in Section 5: <strong>Roof</strong> Membrane 21. Sales information contact<br />

Warranties. 22. Technical information contact<br />

Users of the guide who are interested in additional In Part 2: Test Results for APP modified bitumen<br />

information regarding built-up membrane roof sheet products, specific listing information is as<br />

systems are encouraged <strong>to</strong> refer <strong>to</strong> The NRCA follows:<br />

<strong>Roof</strong>ing and Waterproofing Manual, Fifth Edition. 1. Company name<br />

2. Product name<br />

3. Product description<br />

Modified Bitumen Sheet Membrane 4. Complies with (ASTM standard<br />

designation)<br />

A modified bitumen sheet membrane is defined in The 5. Dimensions and masses of sheet materials<br />

NRCA <strong>Roof</strong>ing and Waterproofing Manual, Fifth 6. Physical properties<br />

Edition as a “composite sheet consisting of a polymer 7. See appendix<br />

modified bitumen often reinforced with various types<br />

of mats or films, and sometimes surfaced films, foils or Reporting of test result data for Items 4, 5 and 6 is<br />

mineral granules.” Polymer modified bitumen is based upon the following American Society for<br />

further defined as “a bitumen modified through the Testing and Materials (ASTM) and Canadian General<br />

inclusion of one or more polymers.” The most Standards Board (CGSB) standards:<br />

common modifiers used in bitumen polymer C ASTM D6222, titled “Standard Specification for<br />

modification are atactic polypropylene (APP) and Atactic Polypropylene (APP) Modified Bituminous<br />

styrene butadiene styrene (SBS).<br />

Sheet Materials Using Polyester Reinforcements”<br />

24


C ASTM D6223, titled “Standard Specification for<br />

Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Materials Using a Combination of Polyester<br />

and Glass Fiber Reinforcements”.<br />

• CGSB 37-GP-56M, titled ‘Standard for Membrane,<br />

Modified Bituminous, Prefabricated and<br />

Reinforced for <strong>Roof</strong>ing”<br />

Users of the guide who are interested in additional<br />

information regarding modified bitumen membrane<br />

roof systems are encouraged <strong>to</strong> refer <strong>to</strong> The NRCA<br />

<strong>Roof</strong>ing and Waterproofing Manual, Fifth Edition.<br />

PVC Single-Ply Membrane<br />

In Part 2: Test Results for SBS modified bitumen A polyvinyl chloride (PVC) single-ply membrane is a<br />

sheet products, specific listing information is as fac<strong>to</strong>ry-manufactured thermoplastic sheet consisting<br />

follows:<br />

of a reinforcing fabric and a synthetic thermoplastic<br />

1. Company name polymer prepared from vinyl chloride.<br />

2. Product name<br />

3. Product description Information on PVC single-ply membrane sheet<br />

4. Complies with (ASTM standard designation) products is presented in the guide in two parts: Part<br />

5. Dimensions and masses of sheet materials 1: General Information and Part 2: Test Results.<br />

6. Physical properties<br />

7. See appendix Specific information included in Part 1: General<br />

Information is as follows:<br />

Reporting of test result data for Items 4, 5 and 6 is 1. Company name<br />

based on the following American Society for Testing 2. Product name<br />

and Materials (ASTM) and Canadian General 3. Product description<br />

Standards Board (CGSB) standards: 4. Coating required<br />

C ASTM D6162, titled “Standard Specification for 5. Use in<br />

Styrene Butadiene Styrene (SBS) Modified 6. Field lap joint method<br />

Bituminous Sheet Materials Using a Combination 7. Types of roof systems<br />

of Polyester and Glass Fiber Reinforcements” 8. Minimum slope required<br />

C ASTM D6163, titled “Standard Specification for 9. Acceptable substrates<br />

Styrene Butadiene Styrene (SBS) Modified 10. Restricted regions<br />

Bituminous Sheet Materials Using Glass Fiber 11. Workable temperature range<br />

Reinforcements” 12. Flashing material<br />

C ASTM D6164, titled “Standard Specification for 13. Flashing method<br />

Styrene Butadiene Styrene (SBS) Modified 14. Preformed accessories available<br />

Bituminous Sheet Materials Using Polyester 15. Country of origin and manufacture<br />

Reinforcements” 16. Year of first commercial use<br />

• CGSB 37-GP-56M, titled ‘Standard for Membrane, 17. Number of squares installed<br />

Modified Bituminous, Prefabricated and 18. Method of distribution<br />

Reinforced for <strong>Roof</strong>ing” 19. Number of regional locations<br />

20. Licensed applica<strong>to</strong>r agreement<br />

In Part 3: Modified Bitumen Specifications, 21. Sales information contact<br />

manufacturers listing information is provided based 22. Technical information contact<br />

upon the following 23. See appendix<br />

1. Company name<br />

2. Manufacturers specification number In Part 2: Test Results, specific information included<br />

3. Type of roof installation and substrate is as follows:<br />

4. Total number of plies<br />

5. Base sheet description 1. Company name<br />

6. Names of sheet products used in membrane 2. Product name<br />

3. Type (ASTM standard designation)<br />

Warranty information for modified bitumen membrane 4. Overall thickness<br />

roof systems is provided in Section 5: <strong>Roof</strong> Membrane 5. Tensile strength<br />

Warranties. 6. Breaking strength<br />

7. Elongation<br />

8. Seam strength<br />

9. Retention of properties after heat aging<br />

25


10. Tear resistance 16. Year of first commercial use<br />

11. Tear strength 17. Number of squares installed<br />

12. Low temperature bend 18. Methods of distribution<br />

13. Accelerated weathering 19. Number of regional locations<br />

14. Linear dimensional change 20. Licensed applica<strong>to</strong>r agreement<br />

15. Change in weight after water immersion 21. Sales information contact<br />

22. Technical information contact<br />

Reporting of test result data in Items 3 though 15 is 23. See appendix<br />

based on American Society for Testing and Materials<br />

(ASTM) Standard D4434-95, titled “Specification for In Part 2: Test Results, specific information included<br />

Poly (Vinyl Chloride) Sheet <strong>Roof</strong>ing.”<br />

is as follows:<br />

1. Company name<br />

Warranty information for PVC single-ply membrane 2. Product name<br />

roof systems is provided in Section 5: <strong>Roof</strong> Membrane 3. Grade<br />

Warranties. 4. Class<br />

5. Thickness<br />

Users of the guide who are interested in additional 6. Breaking strength<br />

information regarding PVC single-ply membrane roof 7. Tensile strength<br />

systems are encouraged <strong>to</strong> refer <strong>to</strong> The NRCA 8. Ultimate elongation<br />

<strong>Roof</strong>ing and Waterproofing Manual, Fifth Edition. 9. Tensile set<br />

10. Tear resistance<br />

11. Tearing strength<br />

EPDM Single-Ply Membrane 12. Brittleness point<br />

13. Ozone resistance<br />

An ethylene propylene diene monomer (EPDM), or 14. Heat aging<br />

terpolymer, single-ply membrane is fac<strong>to</strong>ry- 15. Water absorption<br />

manufactured thermoset single-ply membrane that is 16. Fac<strong>to</strong>ry seam strength<br />

principally composed of two components, ethylene 17. Weather resistance<br />

and propylene. When these components are 18. See appendix<br />

combined with diene, a flexible rubber matrix is<br />

formed. EPDM single-ply membranes are available in Reporting of test result data for Items 3 though 17 is<br />

two types, non-reinforced and reinforced.<br />

based upon American Society for Testing and<br />

Materials (ASTM) Standard D4637-96, titled<br />

Information on EPDM single-ply membrane sheet “Specification for Vulcanized Rubber Sheet Used in<br />

products is presented in the guide in two parts: Part Single-Ply <strong>Roof</strong> Membrane.”<br />

1: General Information and Part 2: Test Results.<br />

Warranty information for EPDM single-ply membrane<br />

Specific information included in Part 1: General roof systems is provided in Section 5: <strong>Roof</strong> Membrane<br />

Information is as follows:<br />

Warranties.<br />

1. Company name<br />

2. Product name Users of the guide who are interested in additional<br />

3. Product description information regarding EPDM single-ply membrane<br />

4. Coatings required roof systems are encouraged <strong>to</strong> refer <strong>to</strong> The NRCA<br />

5. Use in <strong>Roof</strong>ing and Waterproofing Manual, Fifth Edition.<br />

6. Field lap joint method<br />

7. Types of roof systems<br />

8. Minimum slope required CSPE Single-Ply Membrane<br />

9. Acceptable substrates<br />

10. Restricted regions A chlorosulfonated polyethylene (CSPE) single-ply<br />

11. Workable temperature range membrane is fac<strong>to</strong>ry-manufactured thermoset single-<br />

12. Flashing material ply membrane that is principally composed of a<br />

13. Flashing method synthetic rubber material commonly called Hypalon,<br />

14. Preformed accessories available which is a proprietary trade name of a compound<br />

15. Country of origin and manufacture developed by E.I. duPont de Nemours & Co., Inc.<br />

26


Information on CSPE single-ply membrane sheet Reporting of test result data for Items 3 though 19 is<br />

products is presented in the guide in two parts: Part based on American Society for Testing and Materials<br />

1: General Information and Part 2: Test Results. (ASTM) Standard D5019-96, titled “Specification for<br />

Reinforced Non-Vulcanized Polymeric Sheet Used in<br />

Specific information included in Part 1: General <strong>Roof</strong>ing Membrane.”<br />

Information is as follows:<br />

1. Company name Warranty information for CSPE single-ply membrane<br />

2. Product name roof systems is provided in Section 5: <strong>Roof</strong> Membrane<br />

3. Product description Warranties.<br />

4. Coating required<br />

5. Use in Users of the guide who are interested in additional<br />

6. Field lap joint method information regarding CSPE single-ply membrane roof<br />

7. Types of roof systems systems are encouraged <strong>to</strong> refer <strong>to</strong> The NRCA<br />

8. Minimum slope required <strong>Roof</strong>ing and Waterproofing Manual, Fifth Edition.<br />

9. Acceptable substrates<br />

10. Restricted regions PIB Single-Ply Membrane<br />

11. Workable temperature range<br />

12. Flashing material A polyisobutylene (PIB) single-ply membrane is<br />

13. Flashing method fac<strong>to</strong>ry-manufactured thermoset single-ply membrane<br />

14. Preformed accessories available that is composed of a butyl-based compound that is<br />

15. Country of origin and manufacture extruded in<strong>to</strong> sheet form.<br />

16. Year of first commercial use<br />

17. Number of squares installed Information on PIB single-ply membrane sheet<br />

18. Methods of distribution products is presented in the guide in two parts: Part<br />

19. Number of regional locations 1: General Information and Part 2: Test Results.<br />

20. Licensed applica<strong>to</strong>r agreement<br />

21. Sales information contact Specific information included in Part 1: General<br />

22. Technical information contact Information is as follows:<br />

23. See appendix 1. Company name<br />

2. Product name<br />

In Part 2: Test Results, specific information included 3. Product description<br />

is as follows: 4. Coating required<br />

1. Company name 5. Use in<br />

2. Product name 6. Field lap joint method<br />

3. Sheet construction 7. Types of roof systems<br />

4. Thickness 8. Minimum slope required<br />

5. Breaking strength 9. Acceptable substrates<br />

6. Elongation 10. Restricted regions<br />

7. Tearing strength 11. Workable temperature range<br />

8. Low temperature bend 12. Flashing material<br />

9. Linear dimensional change 13. Flashing method<br />

10. Fabric adhesion 14. Preformed accessories available<br />

11. Ply adhesion 15. Country of origin and manufacture<br />

12. Hydrostatic resistance 16. Year of first commercial use<br />

13. Ozone resistance 17. Number of squares installed<br />

14. Weather resistance 18. Methods of distribution<br />

15. Tensile strength 19. Number of regional locations<br />

16. Elongation 20. Licensed applica<strong>to</strong>r agreement<br />

17. Tear resistance 21. Sales information contact<br />

18. Ozone resistance 22. Technical information contact<br />

19. Water absorption 23. See appendix<br />

20. See appendix<br />

27


In Part 2: Test Results, specific information included 4. Coating required<br />

is as follows: 5. For use in<br />

1. Company name 6. Field lap joint method<br />

2. Product name 7. Types of roof systems<br />

3. Thickness 8. Minimum slope required<br />

4. Breaking strength 9. Acceptable substrates<br />

5. Elongation 10. Restricted regions<br />

6. Tearing strength 11. Workable temperature range<br />

7. Low temperature bend 12. Flashing material<br />

8. Linear dimensional change 13. Flashing method<br />

9. Fabric adhesion 14. Preformed accessories available<br />

10. Hydrostatic resistance 15. Country of origin and manufacture<br />

11. Ozone resistance 16. Year of first commercial use<br />

12. Weather resistance 17. Manufacturing plant location(s)<br />

13. Tensile strength of coating 18. Methods of distribution<br />

14. Elongation of coating 19. Number of regional locations<br />

15. Tear resistance of coating 20. Licensed applica<strong>to</strong>r agreement<br />

16. Ozone resistance of coating 21. Sales information contact<br />

17. Water absorption of coating 22. Technical information contact<br />

18. See appendix 23. See appendix<br />

Reporting of test result data for Items 3 though 17 is In Part 2: Test Results, specific information included<br />

based on American Society for Testing and Materials is as follows:<br />

(ASTM) Standard D5019-96, titled “Specification for 1. Company name<br />

Reinforced Non-Vulcanized Polymeric Sheet Used in 2. Product name<br />

<strong>Roof</strong>ing Membrane.” 3. Type/class<br />

4. Physical properties<br />

Warranty information for PIB single-ply membrane 5. See appendix<br />

roof systems is provided in Section 5: <strong>Roof</strong> Membrane<br />

Warranties.<br />

Reporting of test results data for Items 3 and 4 is<br />

based on a draft American Society for Testing and<br />

Users of the guide who are interested in additional Materials (ASTM) product standard for the sheet<br />

information regarding PIB single-ply membrane roof membrane.<br />

systems are encouraged <strong>to</strong> refer <strong>to</strong> The NRCA<br />

<strong>Roof</strong>ing and Waterproofing Manual, Fifth Edition. Warranty information for TPO single-ply membrane<br />

roof systems is provided in Section 5: <strong>Roof</strong> Membrane<br />

Warranties.<br />

TPO Single-Ply Membrane<br />

Users of the guide who are interested in additional<br />

A thermoplastic olefin (TPO) is a fac<strong>to</strong>ry information regarding TPO single-ply membrane roof<br />

manufactured thermoplastic single-ply membrane that systems are encouraged <strong>to</strong> refer <strong>to</strong> The NRCA<br />

is compounded from a blend of polypropylene and <strong>Roof</strong>ing and Waterproofing Manual, Fifth Edition.<br />

ethylene-propylene polymers. TPO single-ply<br />

membranes are available in two types, non-reinforced<br />

and reinforced.<br />

Other Prefabricated Single-Ply Membranes<br />

Information on TPO single-ply membrane sheet Other prefabricated single-ply membrane products<br />

products is presented in the guide in two parts: Part are sheet-applied membrane products that do not fit<br />

1: General Information and Part 2: Test Results. classifications as PVC, EPDM, CSPE, PIB or TPO<br />

products.<br />

Specific information included in Part 1: General<br />

Information is as follows: Information on other prefabricated single-ply<br />

1. Company name membrane products is presented in the guide in two<br />

2. Product name parts: Part 1: General Information and Part 2: Test<br />

3. Product description Results.<br />

28


Specific information included in Part 1: General test methods utilized by the manufacturers are listed<br />

Information is as follows:<br />

within the test data.<br />

1. Company name<br />

2. Product name Warranty information for other prefabricated single-<br />

3. Product description ply membrane roof systems is provided in Section 5:<br />

4. Coating required <strong>Roof</strong> Membrane Warranties.<br />

5. Use in<br />

6. Field lap joint method Users of the guide who are interested in additional<br />

7. Types of roof systems information regarding other prefabricated single-ply<br />

8. Minimum slope required membrane roof systems are encouraged <strong>to</strong> refer <strong>to</strong><br />

9. Acceptable substrates The NRCA <strong>Roof</strong>ing and Waterproofing Manual, Fifth<br />

10. Restricted regions Edition.<br />

11. Workable temperature range<br />

12. Flashing material<br />

13. Flashing method Spray Polyurethane Foam-Based<br />

14. Preformed accessories available<br />

15. Country of origin and manufacture Spray polyurethane foam-based (SPF) roof systems<br />

16. Year of first commercial use consist of a two-part liquid that is spray-applied in the<br />

17. Number of squares installed field <strong>to</strong> form an insulation base. Over this base, a<br />

18. Methods of distribution protective coating is applied, which provides the<br />

19. Number of regional locations weatherproofing component of the roof system.<br />

20. Licensed applica<strong>to</strong>r agreement<br />

21. Sales information contact Information on SPF-based roof system products is<br />

22. Technical information contact presented in the guide in two parts: Part 1: Insulation<br />

23. See appendix and Part 2: Protective Coatings.<br />

In Part 2: Test Results, specific information included Specific information included in Part 1: insulation is as<br />

is as follows:<br />

follows:<br />

1. Company name 1. Company name<br />

2. Product name 2. Product name<br />

3. Product description 3. Recommended types of protective coatings<br />

4. Thickness 4. System coating available from<br />

5. Tensile strength manufacturer<br />

6. Lap joint method 5. Required application conditions<br />

7. Elongation at break 6. Physical properties of the foam<br />

8. Tensile set 7. UL 790, Class A<br />

9. Low temperature flexibility 8. Year of first commercial use<br />

10. Water absorption 9. Number of squares installed<br />

11. Dimensional stability 10. Manufacturer-qualified applica<strong>to</strong>rs required<br />

12. Heat aging 11. Methods of distribution<br />

13. Ozone resistance 12. Number of regional sales locations<br />

14. Accelerated weathering 13. Sales and technical information contacts<br />

15. Dynamic impacting 14. See appendix<br />

16. Tear resistance<br />

17. Tearing strength Specific information included in Part 2: Protective<br />

18. Low temperature impact Coatings is as follows:<br />

19. Permeability 1. Company name<br />

20. Dimensional change 2. Product name<br />

21. Cone penetration 3. Coating description<br />

22. See appendix 4. Name of base coat and <strong>to</strong>p coat<br />

5. Number of coating applications required<br />

Reporting of test results data for Items 4 through 21 6. Required dry film thickness<br />

is based on recognized test methods. The specific 7. Film cure time<br />

test methods utilized are at the discretion of the listing<br />

manufacturers for their specific products; the specific<br />

29


8. Minimum slope required 9. Specialty applications<br />

9. Requirements for use 10. Manufacturer and product data<br />

10. Flashing material 11. ASTM E 1646 water penetration<br />

11. Application conditions 12. ASTM E 1680 air infiltration<br />

12. Application equipment requirements 13. FM/UL wind uplift ratings<br />

13. Restricted regions 14. See appendix<br />

14. Restricted building uses<br />

15. Recommended recoating schedule Users of the guide who are interested in additional<br />

16. Physical properties information regarding metal panel roof systems are<br />

17. UL 790, Class A encouraged <strong>to</strong> refer <strong>to</strong> The NRCA Metal <strong>Roof</strong>ing<br />

18. Foam insulation requirements Manual or The NRCA <strong>Roof</strong>ing and Waterproofing<br />

19. Foam available from manufacturer Manual, Fifth Edition.<br />

20. Year of first commercial use<br />

21. Number of squares installed<br />

22. Manufacturer-qualified applica<strong>to</strong>r<br />

required<br />

23. Methods of distribution<br />

24. Number of regional service locations<br />

25. Sales and technical information contacts<br />

Users of the guide who are interested in additional<br />

information regarding SPF-based roof systems are<br />

encouraged <strong>to</strong> refer <strong>to</strong> The NRCA SPF-Based<br />

<strong>Roof</strong>ing Manual or The NRCA <strong>Roof</strong>ing and<br />

Waterproofing Manual, Fifth Edition.<br />

Metal Panel<br />

Metal panel roof systems are traditionally divided in<strong>to</strong><br />

two categories: structural metal panels and<br />

architectural metal panels. Generally, structural metal<br />

panel roof systems are installed on low-slope roofs,<br />

that is roofs with slopes less than 3:12 (14 degrees).<br />

Architectural metal panel roof systems are generally<br />

installed on steep-slope roof systems, that is roofs<br />

with slopes of 3:12 (14 degrees) or greater.<br />

Structural metal panel roof systems can support<br />

structural loads without being applied over separate<br />

roof decks. Architectural metal panel roof systems<br />

are applied over structural roof decks that resists<br />

structural loads.<br />

Information on metal panel roof systems, both<br />

structural metal panels and architectural metal<br />

panels, is contained in the guide. Specific information<br />

in included is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Architectural/structural applications<br />

4. Panel configuration<br />

5. System requirements<br />

6. Panel profile<br />

7. Seam processing, height and sealant<br />

8. Fastening method<br />

30


EPDM<br />

Index <strong>to</strong> <strong>Roof</strong> <strong>Coverings</strong><br />

METAL ROOF PANELS<br />

SPRAY POLYURETHANE<br />

FOAM-BASED SYSTEM<br />

OTHER PRE-FABRICATED<br />

TPO<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

WARRANTIES<br />

INCOMPLETE<br />

CSPE/PIB<br />

PVC<br />

AEP-SPAN 366<br />

P O Box 150449<br />

Dallas, TX 75315<br />

214/827-1746<br />

FAX: 214/828-1394<br />

E-mail: info@aep-span.com<br />

Web: www.aep-span.com<br />

AMERICAN LUBRICANTS CO. 118 734<br />

1227 Deeds Avenue 172<br />

Day<strong>to</strong>n, OH 45401<br />

937/222-2851<br />

FAX: 937/461-7729<br />

Web:<br />

AMERICAN STEEL BUILDING CO. 369<br />

P O Box 14244<br />

Hous<strong>to</strong>n, TX 77221<br />

800/877-8335 713/433-5661<br />

FAX: 713/433-0847<br />

E-mail: sreiners@hal-pc.com<br />

ANDEK CORPORATION 354<br />

P O Box 392<br />

850 Glen Avenue<br />

Moores<strong>to</strong>wn, NJ 08057-0392<br />

888/88ANDEK (26335)<br />

FAX: 888/44ANDEK (26335)<br />

E-mail: andekcorp@aol.com<br />

ARCHITECTURAL METAL SYSTEMS 369<br />

1150 State Docks Road<br />

Eufaula, AZ 36027<br />

888/621-5020<br />

FAX: 334/687-9297<br />

E-mail: info@ametalsystem.com<br />

ARS INDUSTRIES 372<br />

9606 Parkway East, Suite E<br />

Birmingham, AL 32515<br />

205/836-6777<br />

FAX: 205/836-4090<br />

Web:<br />

ATAS INTERNATIONAL, INC. 374<br />

Iron Run Industrial Park<br />

6612 Snowdrift Road<br />

Allen<strong>to</strong>wn, PA 18106<br />

610/395-8445<br />

FAX: 610/395-9342<br />

E-mail: info@atas.com<br />

BAKOR - div of Henry Company 118 833<br />

284 Watkline Road 196<br />

Mississauga, ON L4Z 1P4<br />

CANADA<br />

905/890-4800<br />

FAX: 905/890-4866<br />

Web: www.bakor.com<br />

31


EPDM<br />

Index <strong>to</strong> <strong>Roof</strong> <strong>Coverings</strong><br />

METAL ROOF PANELS<br />

SPRAY POLYURETHANE<br />

FOAM-BASED SYSTEM<br />

OTHER PRE-FABRICATED<br />

TPO<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

WARRANTIES<br />

INCOMPLETE<br />

CSPE/PIB<br />

PVC<br />

BARRETT COMPANY 44 730<br />

3422 Old Capi<strong>to</strong>l Trail 74<br />

Wilming<strong>to</strong>n, DE 19808<br />

800/647-0100<br />

FAX: 908/647-0100<br />

E-mail:<br />

Web: www.barrettroofs.com<br />

BERRIDGE MANUFACTURING CO. 376 734<br />

<strong>Roof</strong> Division<br />

Hous<strong>to</strong>n, TX 77026<br />

713/223-4971<br />

FAX: 713/433-0847<br />

E-mail: sales@berridge.com<br />

Web: www.berridge.com<br />

BITEC INC. 120 738<br />

#2 Industrial Park Dr. 172<br />

Morril<strong>to</strong>n, AR 72110 199<br />

800/535-8597 264<br />

FAX 501/354-3019<br />

E-mail: dga@bitec.com<br />

Web: www.bi-tec.com<br />

BONDCOTE ROOFING SYSTEMS 336 740<br />

4090 Pepperell Way 342<br />

Dublin, VA 24084<br />

800/358-2160<br />

FAX: 540/674-6511<br />

E-mail: bcrtech@bondcote.com<br />

Web: www.bondcote.com<br />

BUTLER MANUFACTURING CO. 380<br />

BMA Tower<br />

Penn Valley Park<br />

Kansas City, MO 64141<br />

816/968-2370<br />

FAX 816/968-2371<br />

E-mail:<br />

CARLISLE SYNTEC INCORPORATED 301 330 336 740 832<br />

P.O. Box 7000 316 332 343<br />

Carlisle, PA 17013<br />

717/245-7000<br />

FAX 717/245-7245<br />

E-mail:<br />

Web: www.carlislesyntec.com<br />

CELOTEX CORP. 123 305 742 831<br />

4010 Boy Scout Blvd. 173 317<br />

Tampa, FL 33607 265<br />

813/873-1700<br />

FAX: 813/873-4080<br />

E-mail: aharring<strong>to</strong>n@celotex.com<br />

Web:<br />

32


EPDM<br />

Index <strong>to</strong> <strong>Roof</strong> <strong>Coverings</strong><br />

METAL ROOF PANELS<br />

SPRAY POLYURETHANE<br />

FOAM-BASED SYSTEM<br />

OTHER PRE-FABRICATED<br />

TPO<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

WARRANTIES<br />

INCOMPLETE<br />

CSPE/PIB<br />

PVC<br />

CERTAINTEED / <strong>Roof</strong>ing Prods. 46 123 833<br />

750 E. Swedesford Rd 76 173<br />

P O Box 860 203<br />

Valley Forge, PA 19482 266<br />

800/359-7298 FAX: 610/341-7055<br />

Web: www.certainteed.com<br />

CONKLIN CO. 326 355 744<br />

P.O. Box 155 327<br />

Shakopee, MN 55379-0155<br />

800/888-8838<br />

FAX: 952/496-4285<br />

E-mail: marketing@conklin. com<br />

Web: www.conklin.com<br />

COOLEY ENGINEERED 336<br />

MEMBRANE INC. 343<br />

50 Esten Avenue Box 939<br />

Pawtucket, RI 02862-0939<br />

401/724-0490<br />

FAX: 401/726-8731<br />

E-mail: cooleygroup.com<br />

CURVELINE INC. 382<br />

1745 Monticello Court<br />

Ontario, CA 91761<br />

909/947-6022<br />

FAX 909/947-1510<br />

E-mail: curveline@curveline.com<br />

Web: www.met.tile/com/curveline<br />

DANOSA CARIBBEAN INC. 125 746<br />

Box 13757, Santurce Station 205<br />

San Juan, PR 00908-3757 267<br />

787/785-4545<br />

FAX 787/787-3902<br />

E-mail: danosapr@icepr.com<br />

Web: www.danosapr.com<br />

DERMABIT, WATERPROOFING 126 748<br />

INDUSTRIES INC. 175<br />

P O Box 3952 207<br />

Greenville, DE 19807-3952<br />

302/652-2740<br />

FAX: 302/652-0195<br />

E-mail:<br />

DIBITEN 127 748<br />

P.O. Box 5108 175<br />

Denver, CO 80217-5108 268<br />

800/342-4836<br />

FAX 303/978-3904<br />

E-mail:<br />

Web:<br />

33


EPDM<br />

Index <strong>to</strong> <strong>Roof</strong> <strong>Coverings</strong><br />

METAL ROOF PANELS<br />

SPRAY POLYURETHANE<br />

FOAM-BASED SYSTEM<br />

OTHER PRE-FABRICATED<br />

TPO<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

WARRANTIES<br />

INCOMPLETE<br />

CSPE/PIB<br />

PVC<br />

DOW CORNING CORPORATION 355<br />

P.O. Box 994<br />

Midland, MI 48686-0994<br />

517/496-6000<br />

FAX 517/496-8026<br />

E-mail:<br />

Web:<br />

DURO-LAST INC. 337 752<br />

525 Morley Drive 343<br />

Saginaw, MI 48601<br />

800/248-0280 (All U.S.)<br />

FAX 800/432-9331<br />

E-mail: dlsagmi@concentric.com<br />

Web: duro-last.com<br />

ECOLOGY ROOF SYSTEMS 49 127 337 833<br />

505 N. Tustin Avenue #188 79 175 344<br />

Santa Ana, CA 92705 208<br />

714/972-1001 269<br />

FAX: 714/972-1079<br />

E-mail:<br />

Web: www.ecologyroofystems.com<br />

ENGLERT INC. 382<br />

1200 Amboy Ave.<br />

Perth Amboy, NJ 08862<br />

732/826-8614<br />

FAX 732/826-8865<br />

E-mail:<br />

Web:<br />

ERSYSTEMS 306 337 355 754<br />

Elas<strong>to</strong>meric <strong>Roof</strong>ing Systems, Inc. 318 344<br />

50 Medina Street<br />

Loret<strong>to</strong>, MN 55357-0056<br />

612/479-6690 FAX: 612/479-6691<br />

E-mail: ersinfo@ersystems.com<br />

Web: www.ersystems.com<br />

FABRAL 384<br />

3449 Hempland Road<br />

Lancaster, PA 17601<br />

717/397-2741<br />

FAX 717/397-1040<br />

E-mail: fabinf@fabral.com<br />

Web:<br />

FIELDS COMPANY, LLC 49 833<br />

2240 Taylor Way 83<br />

Tacoma, WA 98421<br />

253/627-4098<br />

FAX 253/383-2181<br />

E-mail:<br />

Web:<br />

34


EPDM<br />

Index <strong>to</strong> <strong>Roof</strong> <strong>Coverings</strong><br />

METAL ROOF PANELS<br />

SPRAY POLYURETHANE<br />

FOAM-BASED SYSTEM<br />

OTHER PRE-FABRICATED<br />

TPO<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

WARRANTIES<br />

INCOMPLETE<br />

CSPE/PIB<br />

PVC<br />

FIRESTONE BUILDING 55 129 292 307 330 756<br />

PRODUCTS CO. 86 176 298 319 332<br />

525 Congressional Blvd. 211<br />

Carmel, IN 46032 270<br />

800/428-4442<br />

E-mail: fires<strong>to</strong>nebpco.com<br />

Web:<br />

FLEX MEMBRANE INTERNATIONAL, 292 337 760<br />

INC. 298 345<br />

Bethelem Drive<br />

Morgan<strong>to</strong>wn, PA 19543<br />

610/286-7788<br />

FAX 610/286-7786<br />

E-mail flexroof@compuserve.com<br />

FOAM ENTERPRISES, INC. 352<br />

13630 Water<strong>to</strong>wer Circle 356<br />

Minneapolis, MN 55441<br />

888/900-3626 or 763/559-9390<br />

FAX: 763/559-0945<br />

E-mail: foamnet@aol.com<br />

Web:<br />

FOLLANSBEE STEEL 389<br />

P.O. Box 610<br />

Follansbee, WV 26037<br />

800/624-6906<br />

FAX 304/527-1269<br />

E-mail: folrfg@lbcorp.com<br />

Web:<br />

GAF MATERIALS CORP. 57 131 292 330 762<br />

1361 Alps Road 91 177 298 332<br />

Wayne, NJ 07470 213<br />

973/628-3000 271<br />

800/766-3411<br />

FAX: 973/628-3451<br />

Web: www.gaf.com<br />

GACO WESTERN, INC. 353<br />

P.O. Box 88698 357<br />

Seattle, WA 98138-2698<br />

800/456-4226<br />

FAX 206/575-0587<br />

E-mail:<br />

Web:<br />

GALVAMET, INC. 389<br />

2267 Via Bur<strong>to</strong>n Street<br />

Anaheim, CA 92806<br />

714/758-4848<br />

FAX 714/758-4855<br />

E-mail: jgeortner@galvamet.com<br />

Web:<br />

35


EPDM<br />

Index <strong>to</strong> <strong>Roof</strong> <strong>Coverings</strong><br />

METAL ROOF PANELS<br />

SPRAY POLYURETHANE<br />

FOAM-BASED SYSTEM<br />

OTHER PRE-FABRICATED<br />

TPO<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

WARRANTIES<br />

INCOMPLETE<br />

CSPE/PIB<br />

PVC<br />

GARDNER ASPHALT CORP./APOC 358 833<br />

DIVISION<br />

P.O. Box 5449<br />

Tampa, FL 33675-5449<br />

FAX 813/248-6768<br />

Web:<br />

GARLAND COMPANY INC. 134 390 833<br />

3800 E. 91st Street 217<br />

Cleveland, OH 44105<br />

216/641-7500<br />

FAX 216/641-0633<br />

Web:<br />

G.E. SEALANTS & ADHESIVES 359<br />

16325 Northcross Drive<br />

Charlotte, NC 28078<br />

704/655-2022<br />

E-mail:<br />

GENFLEX ROOFING SYSTEMS 293 308 330 338 792<br />

1722 Indian Wood Circle, Suite A 299 320 333 345<br />

Maumee, OH 43537<br />

800/448-4272<br />

FAX: 419/891-4436<br />

Web: www.genflex.com<br />

HENRY COMPANY 58 137 770<br />

(includes Monsey Bakor, Grundy, Monsey) 96 221<br />

2911 Slauson Avenue 273<br />

Hunting<strong>to</strong>n Park, CA 90255<br />

213/583-5000<br />

FAX 213/582-6429<br />

E-mail:<br />

Web:<br />

HICKMAN SYSTEMS INC., W.P. 69 168 824<br />

30700 Solon Industrial Parkway 113 194<br />

Solon, OH 44139 263<br />

440/248-7760<br />

FAX 440/248-6524<br />

E-mail: wphickman@wphickman.com<br />

Web:<br />

HONEYWELL INTERNATIONAL INC. 59 139 834<br />

2000 Regency Parkway, Suite 225 98 273<br />

Cary, NC 27511-8507<br />

800/221-6490<br />

FAX: 919/46-4720<br />

E-mail:<br />

Web:<br />

HYLOAD 338 774<br />

9976 Rittman Road 346<br />

Wadsworth,OH 44281<br />

800/457-4056<br />

FAX: 330/336-5512<br />

E-mail:<br />

Web:<br />

36


EPDM<br />

Index <strong>to</strong> <strong>Roof</strong> <strong>Coverings</strong><br />

METAL ROOF PANELS<br />

SPRAY POLYURETHANE<br />

FOAM-BASED SYSTEM<br />

OTHER PRE-FABRICATED<br />

TPO<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

WARRANTIES<br />

INCOMPLETE<br />

CSPE/PIB<br />

PVC<br />

IB ROOF SYSTEMS 295<br />

2877 Chad Drive-B 300<br />

Eugene, OR 97408<br />

541/242-2871<br />

FAX: 541/302-6692<br />

E-mail: solution@ibroof.com<br />

Web:<br />

ICA, INC. 139 834<br />

P.O. Box 679 178<br />

Warring<strong>to</strong>n, PA 18976 275<br />

800/352-7002<br />

FAX 215/918-0890<br />

E-mail: hedgese1@aol.com<br />

Web:<br />

IKO INDUSTRIES 139 834<br />

120 Hay Rd. 179<br />

Wilming<strong>to</strong>n, DE 19809 226<br />

302/764-3100 276<br />

FAX 302/764-5852<br />

E-mail:<br />

Web: www.iko.com<br />

INNOVATIVE METALS CO., INC. 390<br />

2070 Steel Drive<br />

Tucker, GA 30084<br />

770/908-1030<br />

FAX 770/908-2264<br />

E-mail:<br />

Web:<br />

INTERCONTINENTAL COATINGS 339<br />

CORP, (I-CON) 348<br />

16744 W. Park Circle Drive<br />

Chagrin Falls, OH 44023<br />

440/543-3114<br />

FAX: 440/543-3443<br />

E-mail:<br />

INTERNATIONAL DIAMOND 308 776<br />

SYSTEMS INC. 320<br />

P.O. Box 351950<br />

Toledo, OH 43635<br />

419/382-0111<br />

FAX 419/382-3275<br />

E-mail: internationaldiamond@att.net<br />

IPS Insulated Panel Systems 391<br />

P . O. Box 968<br />

Stafford, TX 77497-0968<br />

281/499-2605<br />

FAX 281/499-3363<br />

Web: www.insulated-panels.com<br />

37


EPDM<br />

Index <strong>to</strong> <strong>Roof</strong> <strong>Coverings</strong><br />

METAL ROOF PANELS<br />

SPRAY POLYURETHANE<br />

FOAM-BASED SYSTEM<br />

OTHER PRE-FABRICATED<br />

TPO<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

WARRANTIES<br />

INCOMPLETE<br />

CSPE/PIB<br />

PVC<br />

JOHNS MANVILLE INT'L, INC. 60 142 295 309 331 778<br />

<strong>Roof</strong>ing Systems Group 101 179 301 321 333<br />

P.O. Box 5108 229<br />

Denver, CO 80217 277<br />

303/978-2000<br />

FAX 303/978-3904<br />

Web: www.jm.com<br />

KARNAK CORPORATION 62 834<br />

330 Central Avenue 104<br />

Clark, NJ 07066<br />

732/388-0300 800/526-4236<br />

FAX 732/388-9422<br />

Web: www.karnakcorp.com<br />

KOPPERS INDUSTRIES INC. 63 145 786<br />

436 Seventh Avenue 105 181<br />

Pittsburgh, PA 15219 232<br />

800/468-9629 279<br />

FAX: 412/227-2002<br />

Web: www.koppers.com<br />

MALARKEY ROOFING CO. 64 146 786<br />

P.O. Box 17217 108 181<br />

Portland, OR 97217-0217 233<br />

503/283-1191 OR 800/545-1191 280<br />

FAX:<br />

Web:<br />

MBCI/NCI 392<br />

P.O. Box 38217<br />

Hous<strong>to</strong>n, TX 77238<br />

281/445-8555<br />

FAX 281/445-1791<br />

E-mail www.mbci.com<br />

Web:<br />

MCELROY METAL CO. 396<br />

1500 Hamil<strong>to</strong>n Road<br />

Bossier City, LA 71111<br />

318/747-8000<br />

FAX 318/747-8029<br />

Web:<br />

MERCHANT & EVANS INC. 399<br />

100 Connecticut Drive<br />

Burling<strong>to</strong>n, NJ 08016<br />

609/387-3033<br />

FAX 609/387-4838<br />

Web:<br />

METAL SALES MFG CORP 401<br />

7800 State Rd. 60<br />

Sellersburg, IN 47172<br />

812/246-0819<br />

FAX 812/246-0829<br />

E-mail: pserv@aye.net<br />

Web: www.mtlsales.com<br />

38


EPDM<br />

Index <strong>to</strong> <strong>Roof</strong> <strong>Coverings</strong><br />

METAL ROOF PANELS<br />

SPRAY POLYURETHANE<br />

FOAM-BASED SYSTEM<br />

OTHER PRE-FABRICATED<br />

TPO<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

WARRANTIES<br />

INCOMPLETE<br />

CSPE/PIB<br />

PVC<br />

MFM BUILDING PRODUCTS CORP. 65 834<br />

P.O. Box 340 109<br />

520 Orange St.<br />

Coshoc<strong>to</strong>n, OH 43812<br />

7404/622-2645 800/882-7663<br />

E-mail: mfm@coshoc<strong>to</strong>n.com<br />

Web:<br />

MULE HIDE PRODUCTS CO., INC. 296 310 326 790<br />

2924 Wyetta Drive 301 322 327<br />

Beloit, WI 53511<br />

608/365-3111<br />

FAX: 608/365-7852<br />

E-mail:<br />

Web:<br />

NATIONAL COATINGS CORP. 359<br />

1201 Calle Suerte<br />

Camarillo, CA 93012<br />

805/388-7112<br />

FAX 805/388-8140<br />

E-mail: nationalcoatings.com<br />

Web:<br />

NEOGARD, DIV JONES BLAIR 359<br />

6900 Maple Avenue P.O. Box 35288<br />

Dallas, TX 75235<br />

800/321-6588<br />

FAX 214/357-7532<br />

E-mail: neogard@neogard.org<br />

Web:<br />

NORTH CAROLINA FOAM IND. 353<br />

1515 Carter St. P.O. Box 1528<br />

Mount Airy, NC 27030<br />

336/789-9161<br />

FAX 336/789-9586<br />

E-mail: rogerm@ncfi.com<br />

Web site: www.ncfi.com<br />

PERFORMANCE ROOF SYSTEMS 147 794 831<br />

4821 Chelsea Ave. 181<br />

Kansas City, MO 64130 282<br />

816/921-0221<br />

FAX 816/921-5540<br />

E-mail: prshunt@aol.com<br />

Web:<br />

PETERSEN ALUMINUM 402<br />

1005 Tonne Rd.<br />

Elk Grove Village, IL 60007<br />

800/323-1960<br />

FAX 800/722-7150<br />

E-mail:<br />

www.pac-clad.com<br />

39


EPDM<br />

Index <strong>to</strong> <strong>Roof</strong> <strong>Coverings</strong><br />

METAL ROOF PANELS<br />

SPRAY POLYURETHANE<br />

FOAM-BASED SYSTEM<br />

OTHER PRE-FABRICATED<br />

TPO<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

WARRANTIES<br />

INCOMPLETE<br />

CSPE/PIB<br />

PVC<br />

PLASTIC COATINGS CORP. 360<br />

P.O. Box 1068<br />

St. Albans, WV 25177<br />

304/755-9151<br />

FAX 304/755-0229<br />

E-mail:<br />

Web:<br />

POLYGLASS USA 148 831<br />

150 Lyon Drive 183 834<br />

Fernley, NV 89408 234<br />

702/575-6007 283<br />

FAX 702/575-2314<br />

E-mail: cus<strong>to</strong>merservice@polyglass.com<br />

Web: www.polyglass.com<br />

PROTECTIVE COATINGS INC. 311 796<br />

1602 Birchwood Avenue 323<br />

Fort Wayne, IN 46803<br />

800/992-8299<br />

FAX: 219/422-7147<br />

E-mail:<br />

Web:<br />

QUANTUM COATING 361<br />

9200 Latty Avenue<br />

St. Louis, MO 63042<br />

800/624-4995<br />

FAX: 314/524-6522<br />

E-mail:<br />

Web:<br />

REPUBLIC POWDERED METALS 328 796 833<br />

3735 Green Road 329<br />

Beachwood, OH 44122<br />

800/551-7081<br />

FAX: 888/742-1759<br />

E-mail:<br />

Web:<br />

ROOFING PRODUCTS 312 798<br />

INTERNATIONAL 324<br />

57460 Dewitt St.<br />

Elkhart, IN 46517<br />

800/628-2957 219/293-9096<br />

FAX 219/294-3450<br />

E-mail:<br />

Web: www.roofingproductsint.com<br />

SARNAFIL INC. 296 800<br />

100 Dan Road 302<br />

Can<strong>to</strong>n, MA 02021<br />

800/451-2504<br />

FAX: 781/828-3529<br />

E-mail: webmaster@sarnafil.com<br />

Web: www.sarnafilus.com<br />

40


EPDM<br />

Index <strong>to</strong> <strong>Roof</strong> <strong>Coverings</strong><br />

METAL ROOF PANELS<br />

SPRAY POLYURETHANE<br />

FOAM-BASED SYSTEM<br />

OTHER PRE-FABRICATED<br />

TPO<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

WARRANTIES<br />

INCOMPLETE<br />

CSPE/PIB<br />

PVC<br />

SEAMAN CORPORATION 341 800<br />

FiberTite <strong>Roof</strong>ing Systems by Seaman 350<br />

1000 Venture Blvd.<br />

Wooster, OH 44691<br />

800/927-8578<br />

FAX: 800/649-2737<br />

E-mail: fibertite.com<br />

SIPLAST INC. 151 804<br />

1111 Hwy. 67 South 236<br />

Arkadelphia, AR 71923 284<br />

870/246-8094<br />

FAX: 870/246-3696<br />

E-mail: tkersey@siplast.com<br />

Web:<br />

SOPREMA, INC. 153 806<br />

310 Quadral Drive 241<br />

Wadsworth, OH 44281<br />

330/334-0066 800/356-3521<br />

FAX 330/334-4289<br />

E-mail:<br />

Web:<br />

SOUTHWESTERN PETROLEUM 66 158 806<br />

CORPORATION (SWEPCO) 111 187<br />

534 No. Main St. P.O. Box 961005 285<br />

Fort Worth, TX 76161-0005<br />

817/332-2336 800/877-9372<br />

FAX 817/877-4047<br />

E-mail: swepcousa.com<br />

STEELOX ROOF SYSTEMS 405<br />

P.O. Box 8181<br />

Mason, OH 45040-8181<br />

513/573-5200<br />

FAX 513/573-5511<br />

E-mail: tab.colbert@steelox.com<br />

Web:<br />

STEVENS ROOFING SYSTEMS 326 331 784<br />

J.P.S. Elas<strong>to</strong>merics Corp. 327 334<br />

9 Sullivan Road<br />

Holyoke, MA 01040-2800<br />

800/621-ROOF<br />

FAX 413/552-1198<br />

E-mail: info@stvroof.com<br />

SWD URETHANE COMPANY 353<br />

222 South Date St. 363<br />

Mesa, AZ 85210<br />

480/969-8413 800/828-1394<br />

FAX 480/461-6926<br />

E-mail: whip@swdurethane.com<br />

Web: www.swdurethane.com<br />

41


EPDM<br />

Index <strong>to</strong> <strong>Roof</strong> <strong>Coverings</strong><br />

METAL ROOF PANELS<br />

SPRAY POLYURETHANE<br />

FOAM-BASED SYSTEM<br />

OTHER PRE-FABRICATED<br />

TPO<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

WARRANTIES<br />

INCOMPLETE<br />

CSPE/PIB<br />

PVC<br />

TAMKO ROOFING PRODUCTS, INC. 67 158 808<br />

220 West 4th Street PO Box 1404 111 248<br />

Joplin, MO 64802 285<br />

417/624-6644<br />

FAX 417/624-8935<br />

E-mail:<br />

Web: www.tamko.com<br />

TEXAS REFINERY CORP. 159 812 159<br />

One Refinery Place P.O. Box 711 187<br />

Ft. Worth, TX 76101 287<br />

817/332-1161<br />

FAX 817/332-2340<br />

E-mail<br />

Web: www.texasrefinery.com<br />

TEXSA, S.A. 160 814 834<br />

Poligono Can Pelegri 187<br />

San Andreu de la Barca, Spain 250<br />

34-3-6820770 287<br />

FAX 34-3-6820752<br />

E-mail:<br />

Web:<br />

TREMCO INC. 68 166 326 814<br />

3735 Green Rd. 112 251 327<br />

P.O. Box 228069 328<br />

Beachwood, OH 44122-8069 329<br />

216/292-5000<br />

FAX: 216/766-5629<br />

Web: www.tremcoroofing.com<br />

UNITED COATINGS 363<br />

19011 E Cataldo<br />

Greenacres, WA 99016<br />

509/926-7143<br />

FAX 509/928-1116<br />

E-mail: info@unitedcoatings<br />

Web: www.unitedcoatings.com<br />

UNITED STEEL DECK INC. 407<br />

475 Springfield Avenue<br />

P.O. Box 662<br />

Summit, NJ 07902-0662<br />

908/277-1617<br />

FAX 908/277-1619<br />

E-mail: heagler@ix.netcom.com<br />

U.S. INTEC INC. 167 816<br />

1361 Alps Road 193<br />

Wayne, NJ 07470 259<br />

973/628-3000 or 800/766-3411 287<br />

FAX: 973/628-3451<br />

E-mail:<br />

Web: www.gaf.com<br />

42


EPDM<br />

Index <strong>to</strong> <strong>Roof</strong> <strong>Coverings</strong><br />

METAL ROOF PANELS<br />

SPRAY POLYURETHANE<br />

FOAM-BASED SYSTEM<br />

OTHER PRE-FABRICATED<br />

TPO<br />

MODIFIED BITUMEN<br />

BUILT-UP ROOFING<br />

WARRANTIES<br />

INCOMPLETE<br />

CSPE/PIB<br />

PVC<br />

VERSICO INCORPORATED 313 341 822<br />

3485 Fortuna Drive 325 350<br />

Akron, OH 44312<br />

330/644-6700 800/992-7663<br />

FAX 330/644-2613<br />

E-mail:<br />

Web:<br />

VINCENT METAL GOODS 409<br />

P.O. Box 360<br />

Minneapolis, MN 55440<br />

763/717-9000<br />

FAX 763/717-7122<br />

E-mail:<br />

Web: www.vincentmetalgoods.com<br />

W P HICKMAN SYSTEMS INC. 69 168 824<br />

30700 Solon Industrial Parkway 113 193<br />

Solon, OH 44139 259<br />

440/248-7760<br />

FAX 440/248-6524<br />

E-mail: wphickman@wphickman.com<br />

Web: www.wphickman.com<br />

43


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME BARRETT BARRETT<br />

COMPANY<br />

COMPANY<br />

2. PRODUCT NAME RAM-TOUGH RAM-TOUGH<br />

3. PRODUCT DESCRIPTION<br />

Base Sheet<br />

Ply Sheet<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II)<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

POLY FELT RAM 30<br />

265VP<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI)<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI) X X<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

5. PRODUCT WIDTH 39-1/2" 39-1/2"<br />

6. MANUFACTURERS PLANT LOCATIONS ALLENTOWN, PA ALLENTOWN, PA<br />

X<br />

GREENVILLE, SC<br />

X<br />

X<br />

GREENVILLE, SC<br />

MILLINGTON,NJ<br />

MILLINGTON,NJ<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTOR DISTRIBUTOR<br />

DIRECT<br />

DIRECT<br />

8. NUIMBER OF REGIONAL LOCATIONS 2 2<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES<br />

10. SALES INFORMATION CONTACT DAVE HANZG DAVE HANZG<br />

800/647-0120 800/647-0120<br />

11. TECHNICAL INFORMATION CONTACT TECH SERVICE TECH SERVICE<br />

800/647-0120 800/647-0120<br />

12. SEE MEMBRANE APPENDIX IF CHECKED<br />

44


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

BARRETT BARRETT BARRETT BARRETT BARRETT BARRETT<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

RAM-TOUGH RAM-TOUGH RAM-TOUGH RAM-TOUGH RAM-TOUGH RAM-TOUGH<br />

RAM GLASS 4 RAM GLASS 6 POLY FELT RAM 32 RAM GLASS RAM GLASS<br />

155 VP MAT CAP SHEET<br />

X X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

36" 36" 39-1/2" 36" 12 " AND 36" 36"<br />

ALLENTOWN, PA ALLENTOWN, PA ALLENTOWN, PA ALLENTOWN, PA ALLENTOWN, PA ALLENTOWN, PA<br />

GREENVILLE, SC GREENVILLE, SC GREENVILLE, SC GREENVILLE, SC GREENVILLE, SC GREENVILLE, SC<br />

MILLINGTON,NJ MILLINGTON,NJ MILLINGTON,NJ MILLINGTON,NJ MILLINGTON,NJ MILLINGTON,NJ<br />

DISTRIBUTOR DISTRIBUTOR DISTRIBUTOR DISTRIBUTOR DISTRIBUTOR DISTRIBUTOR<br />

DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT<br />

2 2 2 2 2 2<br />

YES YES YES YES YES YES<br />

DAVE HANZG DAVE HANZG DAVE HANZG DAVE HANZG DAVE HANZG DAVE HANZG<br />

800/647-0120 800/647-0120 800/647-0120 800/647-0120 800/647-0120 800/647-0120<br />

TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE<br />

800/647-0120 800/647-0120 800/647-0120 800/647-0120 800/647-0120 800/647-0120<br />

45


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME BARRETT CERTAINTEED<br />

COMPANY<br />

CORPORATION<br />

2. PRODUCT NAME RAM-TOUGH FLINTGLAS<br />

RAM 203<br />

CAP SHEET<br />

3. PRODUCT DESCRIPTION<br />

Base Sheet<br />

X<br />

Ply Sheet<br />

X<br />

Cap Sheet X X<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II)<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI)<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X") X X<br />

5. PRODUCT WIDTH 36" 36"<br />

6. MANUFACTURERS PLANT LOCATIONS ALLENTOWN, PA CHESTER, PA<br />

X<br />

X<br />

GREENVILLE, SC<br />

LITTLE ROCK, AK<br />

MILLINGTON,NJ<br />

LOS ANGELES, CA<br />

SHREVEPORT, LA<br />

SOUTHGATE, CA<br />

WILMINGTON, CA<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTOR DISTRIBUTORS<br />

DIRECT<br />

8. NUIMBER OF REGIONAL LOCATIONS 2 3<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES<br />

10. SALES INFORMATION CONTACT DAVE HANZG REGIONAL<br />

800/647-0120<br />

11. TECHNICAL INFORMATION CONTACT TECH SERVICE<br />

800/647-0120<br />

12. SEE MEMBRANE APPENDIX IF CHECKED<br />

46


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED<br />

CORPORATION CORPORATION CORPORATION CORPORATION CORPORATION CORPORATION<br />

FLEXIGLAS FLEXIGLAS GLASBASE ALL WEATHER / NO. 15 YOSEMITE<br />

PREMIUM CAP BASE SHEET BASE SHEET EMPIRE BASE PERFORATED BUFFER BASE<br />

SHEET 960 SHEET FELT SHEET<br />

X X X X<br />

X<br />

X<br />

TYPE II<br />

TYPE I<br />

X<br />

X<br />

36" 36" 36" 36" 36" 36"<br />

CHESTER, PA CHESTER, PA CHESTER, PA CHESTER, PA CHESTER, PA CHESTER, PA<br />

LITTLE ROCK, AK LITTLE ROCK, AK LITTLE ROCK, AK LITTLE ROCK, AK LITTLE ROCK, AK LITTLE ROCK, AK<br />

LOS ANGELES, CA LOS ANGELES, CA LOS ANGELES, CA LOS ANGELES, CA LOS ANGELES, CA LOS ANGELES, CA<br />

SHREVEPORT, LA SHREVEPORT, LA SHREVEPORT, LA SHREVEPORT, LA SHREVEPORT, LA SHREVEPORT, LA<br />

SOUTHGATE, CA SOUTHGATE, CA SOUTHGATE, CA SOUTHGATE, CA SOUTHGATE, CA SOUTHGATE, CA<br />

WILMINGTON, CA WILMINGTON, CA WILMINGTON, CA WILMINGTON, CA WILMINGTON, CA WILMINGTON, CA<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

3 3 3 3 3 3<br />

YES YES YES YES YES YES<br />

REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

47


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME CERTAINTEED CERTAINTEED<br />

CORPORATION<br />

CORPORATION<br />

2. PRODUCT NAME FLINTGLAS FLINTGLAS<br />

3. PRODUCT DESCRIPTION<br />

PLY SHEET<br />

TYPE IV<br />

PLY SHEET<br />

Base Sheet<br />

Ply Sheet X X<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II)<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

TYPE VI<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI) TYPE IV TYPE VI<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

5. PRODUCT WIDTH 36" 36"<br />

6. MANUFACTURERS PLANT LOCATIONS CHESTER, PA CHESTER, PA<br />

LITTLE ROCK, AK<br />

LITTLE ROCK, AK<br />

LOS ANGELES, CA<br />

SHREVEPORT, LA<br />

SOUTHGATE, CA<br />

WILMINGTON, CA<br />

LOS ANGELES, CA<br />

SHREVEPORT, LA<br />

SOUTHGATE, CA<br />

WILMINGTON, CA<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS<br />

8. NUIMBER OF REGIONAL LOCATIONS 3 3<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES<br />

10. SALES INFORMATION CONTACT REGIONAL REGIONAL<br />

11. TECHNICAL INFORMATION CONTACT<br />

12. SEE MEMBRANE APPENDIX IF CHECKED<br />

48


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

ECOLOGY ECOLOGY ECOLOGY FIELDS FIELDS FIELDS<br />

ROOF SYSTEMS ROOF SYSTEMS ROOF SYSTEMS COMPANY, LLC COMPANY, LLC COMPANY, LLC<br />

ERS ERS ERS F50 F 52 F 54<br />

400-6 401 400 POLYSHIELD GLASBASE 2 GLASPLY 4<br />

X X X<br />

X X X<br />

TYPE II TYPE I X TYPE II<br />

X TYPE IV<br />

TYPE I<br />

40" 36" 36"<br />

TUSCALOOSA, MI TUSCALOOSA, MI TUSCALOOSA, MI TACOMA, WA TACOMA, WA TACOMA, WA<br />

DIRECT DIRECT DIRECT DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

4 4 4 15+ 15+ 15+<br />

YES YES YES YES YES YES<br />

ED NELSON ED NELSON ED NELSON T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA<br />

714/972-1001 714/972-1001 714/972-1001 800/627-4098 800/627-4098 800/627-4098<br />

BILL PFIEFER BILL PFIEFER BILL PFIEFER B. SHEIN B. SHEIN B. SHEIN<br />

714/972-1001 714/972-1001 714/972-1001 800/627-4098 800/627-4098 800/627-4098<br />

49


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME FIELDS FIELDS<br />

COMPANY, LLC<br />

COMPANY, LLC<br />

2. PRODUCT NAME F 55 M 60<br />

POLY SHIELD 2<br />

RUBRPOLY<br />

3. PRODUCT DESCRIPTION<br />

Base Sheet X X<br />

Ply Sheet X X<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II) X X<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI) X X<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

5. PRODUCT WIDTH 40 40"<br />

6. MANUFACTURERS PLANT LOCATIONS TACOMA, WA TACOMA, WA<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS<br />

8. NUIMBER OF REGIONAL LOCATIONS 15+ 15+<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES<br />

10. SALES INFORMATION CONTACT T. VANDERLINDA T. VANDERLINDA<br />

800/627-4098 800/627-4098<br />

11. TECHNICAL INFORMATION CONTACT B. SHEIN B. SHEIN<br />

800/627-4098 800/627-4098<br />

12. SEE MEMBRANE APPENDIX IF CHECKED<br />

50


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS<br />

COMPANY, LLC COMPANY, LLC COMPANY, LLC COMPANY, LLC COMPANY, LLC COMPANY, LLC<br />

M 62 M 64 M 66 M 68 M 69 P 70<br />

RUBRGLAS RUBRPOLY 42 RUBRGLAS 2 GLASS RUBR CAP POLY RUBR CAP POLY ROOF<br />

X X X<br />

X X X X<br />

X<br />

X<br />

X X X<br />

X X X<br />

TYPE II<br />

40" 40" 36" 36" 40" 40"<br />

TACOMA, WA TACOMA, WA TACOMA, WA TACOMA, WA TACOMA, WA TACOMA, WA<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

15+ 15+ 15+ 15+ 15+ 15+<br />

YES YES YES YES YES YES<br />

T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA<br />

800/627-4098 800/627-4098 800/627-4098 800/627-4098 800/627-4098 800/627-4098<br />

B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN<br />

800/627-4098 800/627-4098 800/627-4098 800/627-4098 800/627-4098 800/627-4098<br />

51


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME FIELDS FIELDS<br />

COMPANY, LLC<br />

COMPANY, LLC<br />

2. PRODUCT NAME P 72 P 74<br />

POLY ROOF 2<br />

POLYWEB<br />

3. PRODUCT DESCRIPTION<br />

Base Sheet<br />

Ply Sheet X X<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II)<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI)<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

TYPE II<br />

5. PRODUCT WIDTH 40" 6"<br />

TYPE VII<br />

6. MANUFACTURERS PLANT LOCATIONS TACOMA, WA TACOMA, WA<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS<br />

8. NUIMBER OF REGIONAL LOCATIONS 15+ 15+<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES<br />

10. SALES INFORMATION CONTACT T. VANDERLINDA T. VANDERLINDA<br />

800/627-4098 800/627-4098<br />

11. TECHNICAL INFORMATION CONTACT B. SHEIN B. SHEIN<br />

800/627-4098 800/627-4098<br />

12. SEE MEMBRANE APPENDIX IF CHECKED<br />

52


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS<br />

COMPANY, LLC COMPANY, LLC COMPANY, LLC COMPANY, LLC COMPANY, LLC COMPANY, LLC<br />

P 75 P 76 P 77 P 78 P 79 G 360<br />

POLYWEB POLYWEB POLYTEX POLYTEX POLYTEX 2 GLASWEB<br />

X X X X X X<br />

TYPE VII<br />

TYPE VII<br />

TYPE III<br />

36" 36" 40" 40" 40" 36"<br />

TACOMA, WA TACOMA, WA TACOMA, WA TACOMA, WA TACOMA, WA TACOMA, WA<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

15+ 15+ 15+ 15+ 15+ 15+<br />

YES YES YES YES YES YES<br />

T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA<br />

800/627-4098 800/627-4098 800/627-4098 800/627-4098 800/627-4098 800/627-4098<br />

B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN<br />

800/627-4098 800/627-4098 800/627-4098 800/627-4098 800/627-4098 800/627-4098<br />

53


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME FIELDS FIELDS<br />

COMPANY, LLC<br />

COMPANY, LLC<br />

2. PRODUCT NAME G 362 G 60<br />

GLASWEB<br />

GLASWEB<br />

3. PRODUCT DESCRIPTION<br />

Base Sheet<br />

Ply Sheet X X<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II)<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI)<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III) TYPE I TYPE III<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

5. PRODUCT WIDTH 36" 6"<br />

6. MANUFACTURERS PLANT LOCATIONS TACOMA, WA TACOMA, WA<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS<br />

8. NUIMBER OF REGIONAL LOCATIONS 15+ 15+<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES<br />

10. SALES INFORMATION CONTACT T. VANDERLINDA T. VANDERLINDA<br />

800/627-4098 800/627-4098<br />

11. TECHNICAL INFORMATION CONTACT B. SHEIN B. SHEIN<br />

800/627-4098 800/627-4098<br />

12. SEE MEMBRANE APPENDIX IF CHECKED<br />

54


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

FIELDS FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE<br />

COMPANY, LLC BUILDING BUILDING BUILDING BUILDING BUILDING<br />

PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS<br />

G 62 MB BASE VENTING BASE PLY IV PLY VI METAL<br />

GLASWEB<br />

FLASH AL<br />

X<br />

X<br />

X X X<br />

TYPE II<br />

TYPE II<br />

X<br />

TYPE IV<br />

TYPE VI<br />

TYPE I<br />

6" 36" 36" 36"<br />

TACOMA, WA INDIANAPOLIS, IN BEECH GROVE, IN INDIANAPOLIS, IN INDIANAPOLIS, IN PUERTO RICO<br />

TUSCALOOSA, AL TUSCALOOSA, AL TUSCALOOSA, AL<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTOR DISTRIBUTOR DISTRIBUTORS DISTRIBUTORS<br />

15+ 5 5 5 5 5<br />

YES YES YES YES YES YES<br />

T. VANDERLINDA REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

800/627-4098 SALES OFFICE SALES OFFICE SALES OFFICE SALES OFFICE SALES OFFICE<br />

B. SHEIN REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

800/627-4098 COORDINATOR COORDINATOR COORDINATOR COORIDNATOR COORDINATOR<br />

X<br />

X<br />

55


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME FIRESTONE FIRESTONE<br />

BUILDING<br />

PRODUCTS<br />

BUILDING<br />

PRODUCTS<br />

2. PRODUCT NAME SBS SBS CAP<br />

FLASHING<br />

3. PRODUCT DESCRIPTION<br />

Base Sheet<br />

Ply Sheet<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II)<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix) X X<br />

4B. PLY SHEETS:<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI)<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

5. PRODUCT WIDTH<br />

6. MANUFACTURERS PLANT LOCATIONS INDIANAPOLIS, IN INDIANAPOLIS, IN<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS<br />

8. NUIMBER OF REGIONAL LOCATIONS 5 5<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES<br />

10. SALES INFORMATION CONTACT REGIONAL REGIONAL<br />

SALES OFFICE SALES OFFICE<br />

11. TECHNICAL INFORMATION CONTACT REGIONAL REGIONAL<br />

COORDINATOR COORDINATOR<br />

12. SEE MEMBRANE APPENDIX IF CHECKED X X<br />

56


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

GAF GAF GAF GAF GAF GAF<br />

MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS<br />

CORP. CORP. CORP. CORP. CORP. CORP.<br />

GAFGLAS GAFGLAS MINERAL GAFGLAS STRATAVENT STRATEVENT<br />

PLY 4 FLEX PLY 6 SURFACED #75 BASE PERFORATED NAILABLE<br />

CAP SHEET SHEET BASE SHEET BASE SHEET<br />

X<br />

X<br />

X<br />

X<br />

X<br />

TYPE II<br />

TYPE II<br />

TYPE II<br />

TYPE IV<br />

TYPE VI<br />

X<br />

39-5/8" 39-5/8" 39-5/8" 39-5/8" 39-5/8" 39-5/8"<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

5 5 5 5 5 5<br />

YES YES YES YES YES YES<br />

REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE<br />

TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE<br />

800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411<br />

57


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME GAF HENRY CO.<br />

MATERIALS<br />

CORP.<br />

2. PRODUCT NAME TRI PLY #604<br />

3. PRODUCT DESCRIPTION<br />

Base Sheet<br />

Ply Sheet<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II)<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI)<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

PLY 4<br />

X<br />

TYPE IV<br />

25# FIBERGLASS<br />

BASE SHEET<br />

5. PRODUCT WIDTH 36"<br />

X<br />

TYPE II<br />

6. MANUFACTURERS PLANT LOCATIONS HUNTINGTON PARK, CA<br />

KIMBERTON, PA<br />

GARLAND, TX<br />

INDIANAPOLIS, IN<br />

BARTOW, FL<br />

KINGMAN, AZ<br />

ROCK HILL, SC<br />

PORTLAND, OR<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS<br />

8. NUIMBER OF REGIONAL LOCATIONS 5<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES<br />

10. SALES INFORMATION CONTACT REGIONAL J. HOLLERAN<br />

OFFICE 800/598-7663<br />

11. TECHNICAL INFORMATION CONTACT TECH SERVICE S. LEONARD<br />

800/766-3411 800/486-1278<br />

12. SEE MEMBRANE APPENDIX IF CHECKED X<br />

58


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

HENRY CO. HENRY CO. HENRY CO. HENRY CO. HONEYWELL HONEYWELL<br />

INTERNATIONAL,<br />

INC.<br />

INTERNATIONAL,<br />

#605 #606 #607 #608 BLACK ARMOR POLYMOP<br />

80# MIN SURFACE 80# MIN SURFACE 33# FIBERGLASS #33 FIBERGLASS COAL TAR BUR<br />

UNDERLAYMENT SBS BASE BASE SHEET SBS BASE BUR SYSTEM ROOF SYSTEM<br />

INC.<br />

X X X X X X<br />

X<br />

X<br />

X<br />

X<br />

TYPE II TYPE II TYPE II TYPE II<br />

TYPE II<br />

TYPE II<br />

X<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

36" 36" 36" 36" 36" 36"<br />

HUNTINGTON PARK, CA HUNTINGTON PARK, CA HUNTINGTON PARK, CA HUNTINGTON PARK, CA<br />

KIMBERTON, PA KIMBERTON, PA KIMBERTON, PA KIMBERTON, PA<br />

GARLAND, TX GARLAND, TX GARLAND, TX GARLAND, TX<br />

INDIANAPOLIS, IN INDIANAPOLIS, IN INDIANAPOLIS, IN INDIANAPOLIS, IN<br />

BARTOW, FL BARTOW, FL BARTOW, FL BARTOW, FL<br />

KINGMAN, AZ KINGMAN, AZ KINGMAN, AZ KINGMAN, AZ<br />

ROCK HILL, SC ROCK HILL, SC ROCK HILL, SC ROCK HILL, SC<br />

PORTLAND, OR PORTLAND, OR PORTLAND, OR PORTLAND, OR<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTOR DISTRIBUTOR<br />

DIRECT<br />

DIRECT<br />

YES YES YES YES YES YES<br />

J. HOLLERAN J. HOLLERAN J. HOLLERAN J. HOLLERAN 800/221-6990 800/221-6990<br />

800/598-7663 800/598-7663 800/598-7663 800/598-7663<br />

S. LEONARD S. LEONARD S. LEONARD S. LEONARD 800/221-6990 800/221-6990<br />

800/486-1278 800/486-1278 800/486-1278 800/486-1278<br />

X X X X<br />

59


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME JOHNS JOHNS<br />

MANVILLE<br />

MANVILLE<br />

2. PRODUCT NAME GLASPLY GLASPLY<br />

IV<br />

PREMIER<br />

3. PRODUCT DESCRIPTION<br />

Base Sheet<br />

Ply Sheet X X<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II)<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI) TYPE IV TYPE VI<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

5. PRODUCT WIDTH 36" 36"<br />

6. MANUFACTURERS PLANT LOCATIONS OKLAHOMA CITY, OK OKLAHOMA CITY, OK<br />

MACON, GA<br />

MACON, GA<br />

PITTSBURG,CA<br />

PITTSBURG,CA<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS<br />

8. NUIMBER OF REGIONAL LOCATIONS 5 5<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES<br />

10. SALES INFORMATION CONTACT REGIONAL REGIONAL<br />

OFFICE<br />

OFFICE<br />

11. TECHNICAL INFORMATION CONTACT GUARANTEE GUARANTEE<br />

SERVICES<br />

SERVICES<br />

12. SEE MEMBRANE APPENDIX IF CHECKED<br />

60


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

JOHNS JOHNS JOHNS JOHNS JOHNS JOHNS<br />

MANVILLE MANVILLE MANVILLE MANVILLE MANVILLE MANVILLE<br />

PERMA PLY GLASBASE VENT GLAS KAP GLAS BASE GLAS KAP<br />

28 SOLUTION PLUS PLUS<br />

X X X X<br />

X<br />

X<br />

TYPE II TYPE I TYPE II<br />

TYPE II<br />

X<br />

36" 36" 36" 36" 36" 36"<br />

OKLAHOMA CITY, OK OKLAHOMA CITY, OK OKLAHOMA CITY, OK OKLAHOMA CITY, OK OKLAHOMA CITY, OK OKLAHOMA CITY, OK<br />

MACON, GA MACON, GA MACON, GA MACON, GA MACON, GA MACON, GA<br />

PITTSBURG,CA PITTSBURG,CA PITTSBURG,CA PITTSBURG,CA PITTSBURG,CA PITTSBURG,CA<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

5 5 5 5 5 5<br />

YES YES YES YES YES YES<br />

REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE<br />

GUARANTEE GUARANTEE GUARANTEE GUARANTEE GUARANTEE GUARANTEE<br />

SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES<br />

61


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME KARNAK KARNAK<br />

CORPORATION<br />

CORPORATION<br />

2. PRODUCT NAME #31 #34 UTILITY<br />

3. PRODUCT DESCRIPTION<br />

FIBER GLASS<br />

MEMBRANE<br />

GRADE COTTON<br />

ASPHALT FABRIC<br />

Base Sheet X X<br />

Ply Sheet X X<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II)<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI)<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

TYPE III<br />

5. PRODUCT WIDTH 4, 6, 9, 12, 18, 36" 4, 6, 9, 12, 18, 36"<br />

6. MANUFACTURERS PLANT LOCATIONS CLARK, NJ CLARK, NJ<br />

FT. LAUDERDALE, FL FT. LAUDERDALE, FL<br />

BROADVIEW, IL<br />

BROADVIEW, IL<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS<br />

8. NUIMBER OF REGIONAL LOCATIONS 7 7<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) NO NO<br />

10. SALES INFORMATION CONTACT 800/526-4236 800/526-4236<br />

11. TECHNICAL INFORMATION CONTACT 800/526-4236 800/526-4236<br />

12. SEE MEMBRANE APPENDIX IF CHECKED<br />

62


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

KARNAK KARNAK KOPPERS KOPPERS KOPPERS KOPPERS<br />

CORPORATION CORPORATION INDUSTRIES, INC. INDUSTRIES, INC. INDUSTRIES, INC. INDUSTRIES, INC.<br />

#3036 #5548 TARRED TAR-GLAS PREMIUM ORGANIC<br />

POLY MAT RESAT MAT FELT TAR-GLAS BASE SHEET<br />

X X X<br />

X X X X X<br />

X<br />

X<br />

X<br />

X<br />

4, 6, 9, 12, 18, 36" 36" 36" 36" 36"<br />

CLARK, NJ CLARK, NJ WOODWARD, AL WOODWARD, AL WOODWARD, AL WOODWARD, AL<br />

FT. LAUDERDALE, FL FT. LAUDERDALE, FL<br />

BROADVIEW, IL<br />

BROADVIEW, IL<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

7 7 4 4 4 4<br />

NO NO YES YES YES YES<br />

800/526-4236 800/526-4236 800/558-2706 800/558-2706 800/558-2706 800/558-2706<br />

800/526-4236 800/526-4236 800/468-9629 800/468-9629 800/468-9629 800/468-9629<br />

X X X X<br />

63


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME KOPPERS MALARKEY<br />

INDUSTRIES, INC.<br />

ROOFING<br />

COMPANY<br />

2. PRODUCT NAME GLASS FIBER #515 FIBERGLASS<br />

3. PRODUCT DESCRIPTION<br />

BASE SHEET<br />

STANDARD<br />

BASE SHEET<br />

Base Sheet X X<br />

Ply Sheet<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II) X TYPE I or II<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI)<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

5. PRODUCT WIDTH 36" 39-3/8"<br />

6. MANUFACTURERS PLANT LOCATIONS WOODWARD, AL PORTLAND, OR<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS<br />

8. NUIMBER OF REGIONAL LOCATIONS 4 15<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES<br />

10. SALES INFORMATION CONTACT 800/558-2706 D. CRANFORD<br />

503/283-1191<br />

11. TECHNICAL INFORMATION CONTACT 800/468-9629 J. KOUBA<br />

503/283-1191<br />

12. SEE MEMBRANE APPENDIX IF CHECKED X<br />

64


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

MALARKEY MALARKEY MALARKEY MALARKEY MALARKEY MFM<br />

ROOFING ROOFING ROOFING ROOFING ROOFING BUILDING<br />

COMPANY COMPANY COMPANY COMPANY COMPANY PRODUCTS CORP.<br />

#501 PREMIUM #500 PREMIUM #506 #502 PREMIUM #350 PREMIUM DURAPLY IV<br />

SBS BASE PLY SHEET SUPER 6 MINERAL SBS MINERAL<br />

SHEET TYPE IV PLY SHEET CAP SHEET CAP SHEET<br />

X<br />

X X X<br />

X<br />

X<br />

TYPE I or II<br />

TYPE IV TYPE VI X<br />

X<br />

X<br />

39-3/8" 39-3/8" 39-3/8" 39-3/8" 39-3/8" 36"<br />

PORTLAND, OR PORTLAND, OR PORTLAND, OR PORTLAND, OR PORTLAND, OR COSHOCTON, OH<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

DIRECT<br />

15 15 15 15 15<br />

YES YES YES YES YES NO<br />

D. CRANFORD D. CRANFORD D. CRANFORD D. CRANFORD D. CRANFORD S. FOSTER<br />

503/283-1191 503/283-1191 503/283-1191 503/283-1191 503/283-1191 800/882-7663<br />

J. KOUBA J. KOUBA J. KOUBA J. KOUBA J. KOUBA M. WRIGHT<br />

503/283-1191 503/283-1191 503/283-1191 503/283-1191 503/283-1191 800/882-7663<br />

65


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME MFM SOUTHWESTERN<br />

BUILDING<br />

PRODUCTS CORP.<br />

PETROLEUM<br />

CORPORATION<br />

2. PRODUCT NAME DURABASE ASPHALT<br />

3. PRODUCT DESCRIPTION<br />

Base Sheet<br />

Ply Sheet<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II)<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI)<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

X<br />

X<br />

ROLL<br />

ROOFING<br />

5. PRODUCT WIDTH 36" 36"<br />

6. MANUFACTURERS PLANT LOCATIONS COSHOCTON, OH<br />

X<br />

X<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DIRECT<br />

DIRECT<br />

8. NUIMBER OF REGIONAL LOCATIONS 1<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) NO NO<br />

10. SALES INFORMATION CONTACT S. FOSTER P. DICKERSON<br />

800/882-7663 817/332-2336<br />

11. TECHNICAL INFORMATION CONTACT M. WRIGHT R. KLEINTOP<br />

800/882-7663 817/332-2336<br />

12. SEE MEMBRANE APPENDIX IF CHECKED<br />

66


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO<br />

ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING<br />

PRODUCTS, INC. PRODUCTS, INC. PRODUCTS, INC. PRODUCTS, INC. PRODUCTS, INC. PRODUCTS, INC.<br />

TAM-PLY IV TAM-GLAS VAPOR-CHAN GLASS-BASE TYPE 43 TAM-CAP<br />

PREMIUM<br />

BASE<br />

X<br />

X<br />

X X X<br />

X<br />

TYPE II<br />

TYPE II<br />

X<br />

TYPE IV<br />

TYPE VI<br />

X<br />

39-3/8" 39-3/8" 39-3/8" 39-3/8" 36" 39-3/8"<br />

NAPLES, TX NAPLES, TX NAPLES, TX NAPLES, TX JOPLIN, MO NAPLES, TX<br />

GREEN COVE SPRING, FL<br />

PHILLIPSBURG, KS<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

27 27 27 27 27 27<br />

YES YES YES YES YES YES<br />

DISTRICT DISTRICT DISTRICT DISTRICT DISTRICT DISTRICT<br />

OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE<br />

TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE<br />

800/641-4691 800/641-4691 800/641-4691 800/641-4691 800/641-4691 800/641-4691<br />

67


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME TAMKO TREMCO<br />

ROOFING<br />

PRODUCTS, INC.<br />

2. PRODUCT NAME BASE-N-PLY BURMASTIC<br />

INC.<br />

100<br />

3. PRODUCT DESCRIPTION<br />

Base Sheet<br />

Ply Sheet<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II)<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI)<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

X<br />

TYPE II<br />

5. PRODUCT WIDTH 39-3/8" 36"<br />

6. MANUFACTURERS PLANT LOCATIONS JOPLIN, MO CLEVELAND, OH<br />

X<br />

X<br />

VERNON, CA<br />

MEDINA, OH<br />

TORONTO, ONTARIO<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DIRECT<br />

8. NUIMBER OF REGIONAL LOCATIONS 27 14<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES<br />

10. SALES INFORMATION CONTACT DISTRICT SALES<br />

OFFICE<br />

OFFICE<br />

11. TECHNICAL INFORMATION CONTACT TECH SERVICE TECHNICAL<br />

800/641-4691 DEPT.<br />

12. SEE MEMBRANE APPENDIX IF CHECKED X<br />

68


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

TREMCO TREMCO TREMCO TREMCO W. P. HICKMAN W. P. HICKMAN<br />

INC. INC. INC. INC. SYSTEMS, INC. SYSTEMS, INC.<br />

BURMASTIC BURMASTIC THERM THERM BUR PLUS PIKA PLY<br />

200 300 100 200 POLYESTER PLY CAP SHEET<br />

X X X X X<br />

TYPE VI<br />

X<br />

X<br />

TYPE II<br />

TYPE II<br />

36" 1 M 36" 1 M 39-1/2" 39-1/2"<br />

CLEVELAND, OH CLEVELAND, OH CLEVELAND, OH CLEVELAND, OH<br />

VERNON, CA VERNON, CA VERNON, CA VERNON, CA<br />

MEDINA, OH MEDINA, OH MEDINA, OH MEDINA, OH<br />

TORONTO, ONTARIO TORONTO, ONTARIO TORONTO, ONTARIO TORONTO, ONTARIO<br />

DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT<br />

14 14 14 14 5 5<br />

YES YES YES YES YES YES<br />

SALES SALES SALES SALES C. FITZGERALD C. FITZGERALD<br />

OFFICE OFFICE OFFICE OFFICE<br />

TECHNICAL TECHNICAL TECHNICAL TECHNICAL K. BRZOZOWSKI K. BRZOZOWSKI<br />

DEPT. DEPT. DEPT. DEPT.<br />

X X X X<br />

69


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME W. P. HICKMAN W. P. HICKMAN<br />

SYSTEMS, INC.<br />

SYSTEMS, INC.<br />

2. PRODUCT NAME PREMIUM PLY PERFORMANCE<br />

PLY<br />

3. PRODUCT DESCRIPTION<br />

Base Sheet<br />

X<br />

Ply Sheet X X<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II)<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI)<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

TYPE VI<br />

5. PRODUCT WIDTH 36" 39-1/2"<br />

6. MANUFACTURERS PLANT LOCATIONS<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DIRECT DIRECT<br />

8. NUIMBER OF REGIONAL LOCATIONS 5 5<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES<br />

10. SALES INFORMATION CONTACT C. FITZGERALD C. FITZGERALD<br />

11. TECHNICAL INFORMATION CONTACT K. BRZOZOWSKI K. BRZOZOWSKI<br />

12. SEE MEMBRANE APPENDIX IF CHECKED<br />

70


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

W. P. HICKMAN W. P. HICKMAN W. P. HICKMAN W. P. HICKMAN W. P. HICKMAN W. P. HICKMAN<br />

SYSTEMS, INC. SYSTEMS, INC. SYSTEMS, INC. SYSTEMS, INC. SYSTEMS, INC. SYSTEMS, INC.<br />

MULTI-PLY MULTI-PLY WEATHER PLY WEATHER PLY HK GLASS PLY HICKMAN<br />

GLASS GLASS CL MA MA FR IV WEATHER PLY<br />

X<br />

X<br />

X X X X<br />

X<br />

X<br />

TYPE II<br />

TYPE IV<br />

36" 36" 39.5" 39.5" 36" 39-1/2"<br />

DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT<br />

5 5 5 5 5 5<br />

YES YES YES YES YES YES<br />

C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD<br />

K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI<br />

71


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

1. COMPANY NAME W. P. HICKMAN W. P. HICKMAN<br />

SYSTEMS, INC.<br />

SYSTEMS, INC.<br />

2. PRODUCT NAME HK TARRED HICKMAN<br />

3. PRODUCT DESCRIPTION<br />

FELT<br />

TARRED GLASS<br />

Base Sheet<br />

Ply Sheet X X<br />

Cap Sheet<br />

4. COMPLIES WITH: (indicate type where applicable)<br />

4A. BASE SHEETS:<br />

ASTM D 4601, Asphalt glass-fiber mat base sheet (Type I or II)<br />

ASTM D 4897, Asphalt glass-fiber mat venting base sheet (Type I or II)<br />

ASTM D 2626, Asphalt organic base sheet (Indicate "X")<br />

Other (indicate "X" and describe in Appendix)<br />

4B. PLY SHEETS:<br />

ASTM D 2178, Asphalt glass-fiber felt (Type III, IV or VI)<br />

ASTM D 4990, Coal tar glass-fiber felt (Type I)<br />

ASTM D 226, Asphalt organic felt (Type I)<br />

ASTM D 227, Coal tar organic felt (indicate "X")<br />

ASTM D 1668, Woven-glass fabric (Type I, II or III)<br />

ASTM D 5665, Cold-applied thermoplastic fabric (Types I through VI)<br />

ASTM D 5726, Hot-applied thermoplastic fabric (Types I through VI)<br />

Other (indicate "X" and describe in Appendix)<br />

4C. CAP SHEETS:<br />

ASTM D 249, Roll roofing with granules (Types I or II)<br />

ASTM D 371, Roll roofing with granules, wide selvage (Type I, II, III, or IV)<br />

ASTM D 3909, Glass-fiber felt roll roofing (indicate "X")<br />

5. PRODUCT WIDTH 36" 36"<br />

6. MANUFACTURERS PLANT LOCATIONS<br />

X<br />

TYPE I<br />

TYPE I<br />

7. METHOD OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DIRECT DIRECT<br />

8. NUIMBER OF REGIONAL LOCATIONS 5 5<br />

9. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES<br />

10. SALES INFORMATION CONTACT C. FITZGERALD C. FITZGERALD<br />

11. TECHNICAL INFORMATION CONTACT K. BRZOZOWSKI K. BRZOZOWSKI<br />

12. SEE MEMBRANE APPENDIX IF CHECKED<br />

72


Built-Up <strong>Roof</strong>ing, Part 1 -- General Information<br />

W. P. HICKMAN W. P. HICKMAN W. P. HICKMAN<br />

SYSTEMS, INC. SYSTEMS, INC. SYSTEMS, INC.<br />

HICKMAN PERFORMANCE PERFORMANCE<br />

TARRED GLASS PLY MS PLY MS FR<br />

TYPE II<br />

X<br />

X<br />

X<br />

TYPE II<br />

S<br />

36" 39-1/2" 39-1/2"<br />

DIRECT DIRECT DIRECT<br />

5 5 5<br />

YES YES YES<br />

C. FITZGERALD C. FITZGERALD C. FITZGERALD<br />

K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI<br />

73


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME BARRETT CO.<br />

2. SPECIFICATION NUMBER LEGEND<br />

3. SPECIFICATION NUMBER KLB100.1P-PR KLB100.2P-I K 312-2P-I<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable<br />

X<br />

Insulated<br />

X<br />

Non-nailable<br />

X<br />

6. SLOPE REQUIREMENT (range in inches) 0 - 3 0 - 3 0 - 3<br />

7. NUMBER OF PLIES<br />

Total Plies 1 2 2<br />

Base Sheet<br />

Interply(ies) 1 2 2<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester X X X<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt<br />

X<br />

Modifed Asphalt X X<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) X X<br />

Slag (lbs/ft²) X X<br />

Crushed Rock (lbs/ft²) X X<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback X X<br />

Aluminum Coating X X X<br />

Vinvl/Vinyl Coating X X X<br />

10C. SURFACING - OTHER<br />

Mineral Granules X X X<br />

Cap Sheet X X X<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

X<br />

11A. FLASHING MATERIALS POLYESTER POLYESTER POLYESTER<br />

11B. FLASHING METHOD STANDARD STANDARD STANDARD<br />

BUR BUR BUR<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 0 - 6 0 - 6 2 - 6<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED X X X<br />

74


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

K 312-3P-I K 312-4P-I CP 80-3P CP 80-3M CP 80-4P KLB100-3F-I KLB100-4F-I KLB100-2M KLB100-3M<br />

HOT HOT COLD COLD COLD HOT HOT HOT HOT<br />

X X X X<br />

X X X X<br />

X X X X<br />

0 - 3 0 - 3 1/8 - 3 1/8 - 3 1/8 - 3 0 - 3 0 - 3 0 - 3 0 - 3<br />

3 4 3 3 4 3 4 2 3<br />

1 1 1 1<br />

3 4 3 2 2 3 4 1 1<br />

1 1<br />

X X X X<br />

X X X X X X X X<br />

X<br />

X<br />

X X X<br />

X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X<br />

X X X X X X<br />

X X X X X X<br />

X X X<br />

X X X X X X<br />

X X X<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD STANDARD<br />

BUR BUR BUR BUR BUR BUR BUR BUR BUR<br />

2 - 6 2 - 6 2 - 6 2 - 6 2 - 6 2 - 6 2 - 4 2 - 6 2 - 6<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X<br />

75


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME<br />

2. SPECIFICATION NUMBER LEGEND<br />

CERTAINTEED CORPORATION<br />

SYSTEM SURFACE:<br />

G = Gravel surface<br />

M = Mineral surface<br />

SR = Smooth reinforced<br />

S = Smooth<br />

DECK TYPE:<br />

C = Non Nailable<br />

N = Nailable<br />

3. SPECIFICATION NUMBER G-C-04 G-N-04 G-C-B4<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable<br />

X<br />

Insulated X X X<br />

Non-nailable X X<br />

6. SLOPE REQUIREMENT (range in inches) 0 – 3 0 – 3 0 – 3<br />

7. NUMBER OF PLIES<br />

Total Plies 4 4 4<br />

Base Sheet 1 1 1<br />

Interply(ies) 3 3 3<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber<br />

X<br />

Organic X X<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4 4 4<br />

Slag (lbs/ft²) 3 3 3<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

Aluminum Coating<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS<br />

11B. FLASHING METHOD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²)<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

76


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

BASE SHEET:<br />

TOTAL # PLIES (SYSTEM):<br />

B = Base Sheet 2<br />

P = Ply Sheet 3<br />

O = Organic System 4<br />

5<br />

G-N-B4 G-C-P4 G-C-B3 G-N-B3 G-C-P3 M-C-04 M-N-04 M-C-B4 M-N-B4<br />

HOT HOT HOT HOT HOT HOT HOT HOT/CA HOT/CA<br />

X X X X<br />

X X X X X X X X X<br />

X X X X X<br />

0 – 3 0 – 3 0 – 3 0 – 3 0 – 3 0 – 6 0 – 6 0 – 6 0 – 6<br />

4 4 3 3 3 4 4 4 4<br />

1 1 1 1 1 1 1<br />

3 4 2 2 3 2 2 2 2<br />

1 1 1 1<br />

X X X X X X X X<br />

X<br />

X<br />

X X X X X X X X<br />

4 4 4 4 4<br />

3 3 3 3 3<br />

X<br />

X X X<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

77


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME<br />

2. SPECIFICATION NUMBER LEGEND<br />

CERTAINTEED CORPORATION<br />

SYSTEM SURFACE:<br />

G = Gravel surface<br />

M = Mineral surface<br />

SR = Smooth reinforced<br />

S = Smooth<br />

DECK TYPE:<br />

C = Non Nailable<br />

N = Nailable<br />

3. SPECIFICATION NUMBER M-C-B3 M-N-B3 M-C-B5<br />

4. HOT AND/OR COLD APPLIED HOT/CA HOT/CA HOT/CA<br />

5. DECK TYPE<br />

Nailable<br />

X<br />

Insulated X X X<br />

Non-nailable X X<br />

6. SLOPE REQUIREMENT (range in inches) 0 – 6 0 – 6 0 – 6<br />

7. NUMBER OF PLIES<br />

Total Plies 3 3 5<br />

Base Sheet 1 1 1<br />

Interply(ies) 1 1 3<br />

Cap Sheet 1 1 1<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive X X X<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²)<br />

Slag (lbs/ft²)<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

Aluminum Coating<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet X X X<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS<br />

11B. FLASHING METHOD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²)<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) 1 1 NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

78


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

ECOLOGY ROOF SYSTEMS<br />

BASE SHEET:<br />

B = Base Sheet<br />

P = Ply Sheet<br />

O = Organic System<br />

SEE NEXT PAGE<br />

FOR SPECIFICATION<br />

LEGEND<br />

TOTAL # PLIES<br />

2<br />

3<br />

4<br />

5<br />

M-N-B5 SR-C-B3 SR-N-B3 S-C-B4 S-N-B4 S-C-B3 S-N-B3 1000-3IN-M 1000-3IN-C<br />

HOT/CA HOT/CA HOT/CA HOT/CA HOT/CA HOT/CA HOT/CA HOT HOT<br />

X X X X<br />

X X X X X X X X X<br />

X X X<br />

0 – 6 0 – 6 0 – 6 0 – 6 0 – 6 0 – 6 0 – 6 0 - 1 0 - 1<br />

5 3 3 4 4 3 3 3 3<br />

1 1 1 1 1 1 1 1 1<br />

3 2 2 3 3 2 2 1 2<br />

1 1<br />

X X X X X X X X X<br />

X<br />

X X X X X X X X X<br />

X<br />

X<br />

X X X X X X X<br />

X X X X X X X<br />

X<br />

X<br />

X<br />

X<br />

1.60 1.62<br />

NONE 1 & 2 1 & 2 NONE NONE NONE NONE NONE NONE<br />

79


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME ECOLOGY ROOF SYSTEMS<br />

2. SPECIFICATION NUMBER LEGEND<br />

1000 SERIES BUR<br />

3 = # of Plies<br />

4 = # of Plies<br />

SUBSTRATE TYPE:<br />

IN = Insulated<br />

ND - Nailable Deck<br />

LWT = Lightweight Concrete<br />

CON = Concrete<br />

3. SPECIFICATION NUMBER 1000-3IN-G 1000-3-ND-M 1000-3-ND-C<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable X X<br />

Insulated<br />

X<br />

Non-nailable<br />

6. SLOPE REQUIREMENT (range in inches) 0 - 1 0 - 1 0 - 1<br />

7. NUMBER OF PLIES<br />

Total Plies 3 3 3<br />

Base Sheet 1 1 1<br />

Interply(ies) 2 1 2<br />

Cap Sheet 1<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt X X X<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4<br />

Slag (lbs/ft²) 3<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

X<br />

Aluminum Coating<br />

X<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet<br />

X<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS<br />

11B. FLASHING METHOD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 5.70 1.60 1.62<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

80


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

SYSTEM SURFACE:<br />

M = Mineral Surface<br />

C = Coated Surface<br />

G = Gravel<br />

1000-3-ND-G 1000-3-CON-M 1000-3-CON-C 1000-4-IN-G 1000-4-ND-M 1000-4-ND-C 1000-4-ND-G 1000-4-CON-M 1000-4-CON-C<br />

HOT HOT HOT HOT HOT HOT HOT HOT HOT<br />

X X X X<br />

X X X X X<br />

0 - 1 0 - 2 0 - 2 0 - 1 0 - 1 0 - 1 0 - 1 0 - 2 0 - 2<br />

3 3 3 4 4 4 4 4 4<br />

1 1 1 1 1 1 1 1 1<br />

2 1 2 3 2 3 3 2 3<br />

1 1 1<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

4 4 4<br />

3 3 3<br />

X X X<br />

X X X<br />

X X X<br />

5.70 1.60 1.62 6.0 2.0 2.0 6.0 2.0 2.0<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

81


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME ECOLOGY ROOF SYSTEMS<br />

2. SPECIFICATION NUMBER LEGEND<br />

1000 SERIES BUR<br />

3 = # of Plies<br />

4 = # of Plies<br />

SUBSTRATE TYPE:<br />

IN = Insulated<br />

ND - Nailable Deck<br />

LWT = Lightweight Concrete<br />

CON = Concrete<br />

3. SPECIFICATION NUMBER 1000-3-CON-G 1000-3-LWT-M 1000-3-LWT-C<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable X X<br />

Insulated<br />

Non-nailable<br />

X<br />

6. SLOPE REQUIREMENT (range in inches) 0 - 2 0 -2 0 - 2<br />

7. NUMBER OF PLIES<br />

Total Plies 3 3 3<br />

Base Sheet 1 1 1<br />

Interply(ies) 2 1 2<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt X X X<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4<br />

Slag (lbs/ft²) 3<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

X<br />

Aluminum Coating<br />

X<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet<br />

X<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS<br />

11B. FLASHING METHOD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 5.7 1.6 1.6<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

82


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

FIELDS COMPANY, LLC<br />

SYSTEM SURFACE:<br />

M = Mineral Surface<br />

C = Coated Surface<br />

G = Gravel<br />

SEE NEXT PAGE FOR<br />

SPECIFICATION LEGEND<br />

1000-3-LWT-G 1000-4-IN-M 1000-4-IN-C 1000-4-C0N-G 1000-4-LWT-M 1000-4-LWT-C 1000-4-LWT-G H-337-P(F58) H-335-P(F58)<br />

HOT HOT HOT HOT HOT HOT HOT HOT HOT<br />

X X X X X X<br />

X X X X X<br />

X<br />

X<br />

0 - 2 0 - 1 0 - 1 0 - 2 0 - 2 0 - 2 0 - 2<br />

3 4 4 4 4 4 4 5 5<br />

1 1 1 1 1 1 1 1 1<br />

2 2 3 3 1 3 3 3 3<br />

1 1 1<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X<br />

4 4 4<br />

3 3 3<br />

X<br />

X<br />

X<br />

X<br />

X X X X<br />

5.7 2.0 2.0 6.0 2.0 2.0 6.0 2.50 2.50<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X<br />

X<br />

83


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME FIELDS COMPANY, LLC<br />

2. SPECIFICATION NUMBER LEGEND<br />

ASPHALT CLASS:<br />

B = SEBS Ambient<br />

M = SEBS Hot<br />

A = Ambient Asphalt<br />

H = Hot Asphalt<br />

3. SPECIFICATION NUMBER H-X36-P(F58) H-226-P(M68) H-626-P(M68)<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable X X<br />

Insulated X X X<br />

Non-nailable X X X<br />

6. SLOPE REQUIREMENT (range in inches)<br />

7. NUMBER OF PLIES<br />

Total Plies 4 4 4<br />

Base Sheet 0 1 1<br />

Interply(ies) 3 2 2<br />

Cap Sheet 1 1 1<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²)<br />

Slag (lbs/ft²)<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

Aluminum Coating<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet X X X<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS<br />

11B. FLASHING METHOD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 2.10 2.10 2.10<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED X X X<br />

84


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

BASE SHEET TYPE: TOTAL PLY SHEETS: PLY SHEET TYPE: SURFACING CLASS:<br />

0 = M60 RubrPoly Excludes Base Sheets 0 = M60 RubrPoly C = Reflective Coating<br />

1 = F50 PolyShield and Reflective Cap 1 = F50 PolyShield M = Reflective Minerals<br />

2 = M62 RubrGlas Sheets 2 = M62 RubrGlas P = Reflective Cap Sheets<br />

3 = F52 GlasBase 2 3 = F52 GlasBase 2 A = Asphalt Coating²<br />

4 = M64 RubrPoly2 4 = M64 RubrPoly2<br />

5 = F54 GlasPly4 5 = F54 GlasPly4 SURFACING TYPE³:<br />

6 = M66 RubrGlas2 6 = M66 RubrGlas2 Fields Product Number<br />

7= F56 GlasPly6 7= F56 GlasPly6 for Surfacing Type -<br />

8 = F55 PolyShield2 8 = F55 PolyShield2 Refer <strong>to</strong> Fields Product<br />

9 = Other Sheet¹ 9 = Other Sheet¹ Guide<br />

X = None<br />

X = None<br />

H-626-P(F58) H-627-P(M68) H-625-P(M68) H-327-P(F58) H-325-P(F58) H-226-P(M68) M-X36-P(M68) A-325-C(F640) A-042-C(M630)<br />

HOT HOT HOT HOT HOT HOT HOT COLD COLD<br />

X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

4 4 4 4 4 4 4 3 5<br />

1 1 1 1 1 1 0 1 1<br />

2 2 2 2 2 2 3 2 4<br />

1 1 1 1 1 1 1 0 0<br />

X X X X X X X X X<br />

X<br />

X X X X X X X<br />

X<br />

X<br />

X<br />

X<br />

X X X X X X X<br />

2.10 2.10 2.10 2.0 2.0 2.10 2.10 1.4 1.9<br />

NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X<br />

85


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME FIRESTONE BUILDING PRODUCTS<br />

2. SPECIFICATION NUMBER LEGEND<br />

DECK TYPE:<br />

I = Insulated<br />

S = Steel<br />

C = Concrete<br />

P = Primed<br />

N = Nailable<br />

L = Lightweight<br />

3. SPECIFICATION NUMBER I-3F-G I-3F-AL I-3G-G<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable<br />

Insulated X X X<br />

Non-nailable<br />

6. SLOPE REQUIREMENT (range in inches) 1/4-3 1/4-6 1/4-3<br />

7. NUMBER OF PLIES<br />

Total Plies 3 3 3<br />

Base Sheet<br />

Interply(ies)<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt X X X<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4 4<br />

Slag (lbs/ft²) 3 3<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

Aluminum Coating<br />

X<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS Base, Interply and Base, Interply and Base, Interply and<br />

Membranes listed in 2. Membranes listed in 2. Membranes listed in 2.<br />

11B. FLASHING METHOD Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch<br />

Cold Adhesive Cold Adhesive Cold Adhesive<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 5.9 5.9<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) 1.2<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED X X<br />

86


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

BASE OR INTERPLY TYPE: MEMBRANE TYPES: SURFACING:<br />

M = MB Base S = SBS Base 30 = SBS 16 = APP 160 M = Mineral Granules<br />

V = Vent Base X = SBS Premium Base 31 = SBS FR 17 = APP 170 G = Flood Coat & Gravel<br />

F = Ply 4 44 = SBS Poly Base 32 = SBS Smooth 18 = APP 180 AC = Acrylic Coating<br />

G = Ply 6 32 = SBS Smooth 33 = SBS Premium 18 FR = AL = Aluminum Coating<br />

16 = APP 160 45 = Poly Torch Base 36 = SBS Premium FR APP 180FR P = PMR<br />

17 = APP 170 46 = SBS Glass Torch Base 40 = SBS Torch N = None<br />

80 = APP 80 Glass Base 41 = SBS Torch FR<br />

42 = SBS Metal Flash AL<br />

I-3G-AL I-4F-G I-4F-AL I-4G-G I-4G-AL N-3F-G N-3F-AL N-3G-AL N-3G-AL<br />

HOT HOT HOT<br />

X X X<br />

1/4-6 1/4-3 1/4-6 1/4-3 1/4-3 1/4-3<br />

3 4 4 4 4 4 4 4 4<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

4 4 4 4<br />

3 3 3 3<br />

X X X X X<br />

Base, Interply and Base, Interply and Base, Interply and Base, Interply and Base, Interply and Base, Interply and Base, Interply and Base, Interply and Base, Interply and<br />

Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2.<br />

Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch<br />

Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive<br />

6.3 6.3 6.1 6.1<br />

1.2 1.6 1.6 1.4 1.4<br />

87


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME FIRESTONE BUILDING PRODUCTS<br />

2. SPECIFICATION NUMBER LEGEND<br />

DECK TYPE:<br />

I = Insulated<br />

S = Steel<br />

C = Concrete<br />

P = Primed<br />

N = Nailable<br />

L = Lightweight<br />

3. SPECIFICATION NUMBER N-3G-AL N-3G-AL N-4G-G<br />

4. HOT AND/OR COLD APPLIED<br />

5. DECK TYPE<br />

Nailable<br />

Insulated<br />

Non-nailable<br />

6. SLOPE REQUIREMENT (range in inches)<br />

7. NUMBER OF PLIES<br />

Total Plies 4 4 4<br />

Base Sheet<br />

Interply(ies)<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt X X X<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4 4<br />

Slag (lbs/ft²) 3 3<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

Aluminum Coating<br />

X<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS Base, Interply and Base, Interply and Base, Interply and<br />

Membranes listed in 2. Membranes listed in 2. Membranes listed in 2.<br />

11B. FLASHING METHOD Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch<br />

Cold Adhesive Cold Adhesive Cold Adhesive<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 6.5 6.5<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) 1.8<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

88


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

BASE OR INTERPLY TYPE: MEMBRANE TYPES: SURFACING:<br />

M = MB Base S = SBS Base 30 = SBS 16 = APP 160 M = Mineral Granules<br />

V = Vent Base X = SBS Premium Base 31 = SBS FR 17 = APP 170 G = Flood Coat & Gravel<br />

F = Ply 4 44 = SBS Poly Base 32 = SBS Smooth 18 = APP 180 AC = Acrylic Coating<br />

G = Ply 6 32 = SBS Smooth 33 = SBS Premium 18 FR = AL = Aluminum Coating<br />

16 = APP 160 45 = Poly Torch Base 36 = SBS Premium FR APP 180FR P = PMR<br />

17 = APP 170 46 = SBS Glass Torch Base 40 = SBS Torch N = None<br />

80 = APP 80 Glass Base 41 = SBS Torch FR<br />

42 = SBS Metal Flash AL<br />

N-4G-AL L-3F-G L-3F-AL L-3G-G L-3G-AL L-4F-G L-4F-AL L-4G-G L-4G-AL<br />

HOT HOT HOT HOT<br />

X X X X<br />

1/4-3 1/4-6 1/4-3 1/4-6<br />

4 4 4 4 4 3 3 3 3<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

4 4 4 4<br />

3 3 3 3<br />

X X X X X<br />

Base, Interply and Base, Interply and Base, Interply and Base, Interply and Base, Interply and Base, Interply and Base, Interply and Base, Interply and Base, Interply and<br />

Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2.<br />

Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch<br />

Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive<br />

6.6 6.6 7.0 7.0<br />

1.8 1.9 1.9 2.3 2.3<br />

89


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME FIRESTONE BUILDING PRODUCTS<br />

2. SPECIFICATION NUMBER LEGEND<br />

DECK TYPE:<br />

I = Insulated<br />

S = Steel<br />

BASE OR INTERPLY TYPE:<br />

M = MB Base<br />

V = Vent Base<br />

C = Concrete F = Ply 4<br />

P = Primed G = Ply 6<br />

N = Nailable 16 = APP 160<br />

L = Lightweight 17 = APP 170<br />

80 = APP 80 Glass Base<br />

3. SPECIFICATION NUMBER C-3F-G C-3F-AL C-3G-G<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable<br />

Insulated X X<br />

Non-nailable<br />

6. SLOPE REQUIREMENT (range in inches) 1/4-3 1/4-6<br />

7. NUMBER OF PLIES<br />

Total Plies 4 4 4<br />

Base Sheet<br />

Interply(ies)<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt X X X<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4 4<br />

Slag (lbs/ft²) 3 3<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

Aluminum Coating<br />

X<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS Base, Interply and Base, Interply and Base, Interply and<br />

Membranes listed in 2. Membranes listed in 2. Membranes listed in 2.<br />

11B. FLASHING METHOD Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch<br />

Cold Adhesive Cold Adhesive Cold Adhesive<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 5.9 5.9<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) 1.2<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

90


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

GAF MATERIALS CORP.<br />

MEMBRANE TYPES:<br />

SURFACING:<br />

S = SBS Base 30 = SBS 16 = APP 160 M = Mineral Granules SEE NEXT PAGE FOR<br />

X = SBS Premium Base31 = SBS FR 17 = APP 170 G = Flood Coat & Gravel SPECIFICATION MATRIX<br />

44 = SBS Poly Base 32 = SBS Smooth 18 = APP 180 AC = Acrylic Coating<br />

32 = SBS Smooth 33 = SBS Premium18 FR = AL = Aluminum Coating<br />

45 = Poly Torch Base 36 = SBS Premium FRAPP 180FR P = PMR<br />

46 = SBS Glass Torch 40 Base = SBS Torch N = None<br />

41 = SBS Torch FR<br />

42 = SBS Metal Flash AL<br />

C-3G-AL C-3F-G C-4F-AL C-4G-G C-4G-AL NN-O-4-G I-O-4-G NN-O-4-C I-O-4-C<br />

HOT HOT HOT HOT HOT HOT HOT HOT HOT<br />

X<br />

X<br />

X<br />

X<br />

0 - 3 0 - 3 0 - 6 0 - 6<br />

4 4 4 4 4 4 4 4 4<br />

4 4 4 4<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

4 4 4 4<br />

3 3 3 3<br />

4 4<br />

X<br />

X<br />

X<br />

X<br />

X X X X X<br />

Base, Interply and Base, Interply and Base, Interply and Base, Interply and Base, Interply and RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH<br />

Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. Membranes listed in 2. MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS<br />

Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch Hot Asphalt, Torch HOT/COLD/ HOT/COLD/ HOT/COLD/ HOT/COLD/<br />

Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive Cold Adhesive TORCH TORCH TORCH TORCH<br />

6.3 6.3 6 6 2 2<br />

1.2 1.6 1.6 NONE NONE NONE NONE<br />

X X X X<br />

91


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME GAF MATERIALS CORP.<br />

2. SPECIFICATION NUMBER LEGEND<br />

SUBSTRATE:<br />

I = Insulated<br />

N = Nailable<br />

NN = Non-nailable<br />

3. SPECIFICATION NUMBER NN-B-4-G I-B-4-G NN-B-4-C<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable<br />

Insulated<br />

X<br />

Non-nailable X X<br />

6. SLOPE REQUIREMENT (range in inches) 0 - 3 0 - 3 0 - 6<br />

7. NUMBER OF PLIES<br />

Total Plies 4 4 4<br />

Base Sheet 1 1 1<br />

Interply(ies) 3 3 3<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt X X X<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4 4<br />

Slag (lbs/ft²) 3 3<br />

Crushed Rock (lbs/ft²) 4 4<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

X<br />

Coal Tar<br />

Emulsion/Cutback<br />

X<br />

Aluminum Coating<br />

X<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH<br />

MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS<br />

11B. FLASHING METHOD HOT/COLD/ HOT/COLD/ HOT/COLD/<br />

TORCH TORCH TORCH<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 6 6 2<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED X X X<br />

92


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

BASE SHEET: TOTAL PLIES: SURFACING:<br />

B = Bse Sheet 3 = 3 Plies G = Bitumen & Gravel<br />

O = No Base Sheet 4 = 4 Plies C = Coating<br />

M = Mineral Surfaced Cap Sheet<br />

I-B-4-C NN-0-3-G I-0-3-G NN-B-3-6 I-B-3-G NN-0-3-C I-O-3-C NN-B-3-C I-B-3-C<br />

HOT HOT HOT HOT HOT HOT HOT HOT HOT<br />

X X X X X<br />

X X X X<br />

0 - 6 0 - 3 0 - 3 0 - 3 0 - 3 0 - 6 0 - 6 0 - 6 0 - 6<br />

4 3 3 3 3 3 3 3 3<br />

1 1 1 1<br />

3 3 3 2 2 3 3 3 2<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

4 4 4 4<br />

3 3 3 3<br />

4 4 4 4<br />

X X X X X<br />

X X X X X<br />

X X X X X<br />

RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH<br />

MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS<br />

HOT/COLD/ HOT/COLD/ HOT/COLD/ HOT/COLD/ HOT/COLD/ HOT/COLD/ HOT/COLD/<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH<br />

2 6 6 6 6 2 2 2 2<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X<br />

93


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME GAF MATERIALS CORP.<br />

2. SPECIFICATION NUMBER LEGEND<br />

SUBSTRATE:<br />

I = Insulated<br />

N = Nailable<br />

NN = Non-nailable<br />

3. SPECIFICATION NUMBER NN-O-4-M I-O-4-M NN-B-4-M<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable<br />

Insulated<br />

X<br />

Non-nailable X X<br />

6. SLOPE REQUIREMENT (range in inches) 0 - 6 0 - 6 0 - 6<br />

7. NUMBER OF PLIES<br />

Total Plies 4 4 4<br />

Base Sheet 1<br />

Interply(ies) 3 3 2<br />

Cap Sheet 1 1 1<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt X X X<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²)<br />

Slag (lbs/ft²)<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

Aluminum Coating<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet X X X<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS<br />

11B. FLASHING METHOD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 2 2 2<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED X X X<br />

94


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

BASE SHEET: TOTAL PLIES: SURFACING:<br />

B = Bse Sheet 3 = 3 Plies G = Bitumen & Gravel<br />

O = No Base Sheet 4 = 4 Plies C = Coating<br />

M = Mineral Surfaced Cap Sheet<br />

I-B-4-M NN-O-3-M I-O-3-M N-B-4-G N-B-4-C N-B-3-G N-B-3-C N-B-4-M N-B-3-M<br />

HOT HOT HOT HOT HOT HOT HOT HOT HOT<br />

X X X X X X<br />

X<br />

X<br />

X<br />

0 - 6 0 - 6 0 - 6 0 - 3 0 - 6 0 - 3 0 - 6<br />

4 3 3 4 4 3 3 4 3<br />

1 1 1 1 1 1 1<br />

2 2 2 3 3 2 2 2 1<br />

1 1 1 1 1<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

4 4<br />

3 3<br />

4 4<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X X X<br />

RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH RUBEROID TORCH<br />

MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS MOP/GAFGLAS<br />

HOT/COLD/ HOT/COLD/ HOT/COLD/ HOT/COLD/ HOT/COLD/ HOT/COLD/ HOT/COLD/ HOT/COLD/<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH<br />

2 2 2 6 2 6 2 2 2<br />

NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X<br />

95


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME GAF MATERIALS CORP. HNERY CO.<br />

2. SPECIFICATION NUMBER LEGEND<br />

SUBSTRATE:<br />

I = Insulated<br />

N = Nailable<br />

NN = Non-nailable<br />

TOTAL PLIES:<br />

BASE SHEET:<br />

B = Bse Sheet<br />

O = No Base<br />

SURFACING:<br />

G = Bit & Grvl<br />

3 = 3 Plies C = Coating<br />

4 = 4 Plies M = Mineral<br />

Cap Sheet<br />

3. SPECIFICATION NUMBER I-B-5-M NN-B-5-M H3-NGC-MR<br />

4. HOT AND/OR COLD APPLIED HOT HOT COLD<br />

5. DECK TYPE<br />

Nailable<br />

X<br />

Insulated<br />

X<br />

Non-nailable<br />

X<br />

6. SLOPE REQUIREMENT (range in inches) 1/8 - 3<br />

7. NUMBER OF PLIES<br />

Total Plies 5 5 3<br />

Base Sheet 1 1 1<br />

Interply(ies) 3 3 2<br />

Cap Sheet 1 1<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X<br />

Modifed Asphalt X X<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

X<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²)<br />

Slag (lbs/ft²)<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

X<br />

Aluminum Coating<br />

X<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet X X<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS RUBEROID TORCH RUBEROID TORCH M, R, P<br />

MOP/GAFGLAS MOP/GAFGLAS<br />

11B. FLASHING METHOD HOT/COLD/ HOT/COLD/ COLD<br />

TORCH TORCH<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 2 2 196<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED X X X<br />

Suraced<br />

96


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

H = HENRY 2, 3, 4 = # of Plies PLY TYPE: SURFACING:<br />

M = Modified<br />

R = Ruftac<br />

DECK TYPE: G = Fiberglass Sheets C = Cutback<br />

I = Insulated & Non-nailable P = Polyester E = Emulsion<br />

N - Nailable<br />

GV = Gravel<br />

CR = Cutback + Reflective Coating<br />

GN = Ganules<br />

MR - Monolithic + Reflective Coating<br />

H4-NGC-MR H3-IBC-MR H4-IGC-MR H3-IGC-<br />

GV/VGN<br />

H4-IGC-GV/GN H3-NPE-MR H3-IPE-MR H3-NPE-GV-<br />

GN<br />

H3-IPE-GV/GN<br />

COLD COLD COLD COLD COLD COLD COLD COLD COLD<br />

X X X X X<br />

X X X X<br />

X X X X<br />

0 -3 1/8 - 3 0 - 3 1/8 - 3 1/8 - 3 1/8 - 3 1/8 - 3 1/8 - 3 1/8 - 3<br />

4 3 4 3 4 3 3 3<br />

1 1 1 1 1 1<br />

3 3 4 2 3 2 2 2<br />

X X X X X<br />

X X X X<br />

X X X X X X X X X<br />

4 4 4 4<br />

3 3 3 3<br />

4 4 4 4<br />

X X X X X X X X X<br />

X X X X X<br />

X X X X<br />

M, R, P M, R, P M, R, P M, R, P M, R, P M, R, P M, R, P M, R, P M, R, P<br />

COLD COLD COLD COLD COLD COLD COLD COLD COLD<br />

234 215 252 578 616 169 132 547 509<br />

X X X X X X X X X<br />

97


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME HENRY CO. HONEYWELL<br />

2. SPECIFICATION NUMBER LEGEND (RP) COAL TAR SYSTEMS:<br />

SEE<br />

PREVIOUS<br />

PAGE FOR<br />

SPECIFICATION<br />

IDENTIFICATION<br />

MATRIX<br />

3. SPECIFICATION NUMBER H3-NGC-<br />

GV/GN<br />

PLY TYPE:<br />

4= Tarred Organic<br />

5 = Asphalt Glass<br />

6 = Organic/glass composite<br />

SUBSTRATE:<br />

0 = Nailable<br />

I = Non-nailable or Insulated<br />

4. HOT AND/OR COLD APPLIED COLD HOT HOT<br />

5. DECK TYPE<br />

Nailable X X<br />

Insulated<br />

X<br />

Non-nailable<br />

X<br />

6. SLOPE REQUIREMENT (range in inches) 1/8 - 1/4 0 - 1/2 0 - 1/2<br />

7. NUMBER OF PLIES<br />

Total Plies 4 4<br />

Base Sheet 1<br />

Interply(ies) 3 4<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber<br />

X<br />

Organic X X<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt<br />

Modifed Asphalt<br />

Coal Tar X X<br />

Elas<strong>to</strong>meric Adhesive<br />

X<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4 4 4<br />

Slag (lbs/ft²) 3 3 3<br />

Crushed Rock (lbs/ft²) 4<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

X<br />

Aluminum Coating<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

X<br />

Cap Sheet<br />

Other (Indicate "X" and describe in Membrane Appendix) X X<br />

11A. FLASHING MATERIALS M, R, P<br />

11B. FLASHING METHOD COLD HOT / HOT /<br />

COLD COLD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 646 6.0 6.0<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED X<br />

RP-40<br />

RP-41<br />

98


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

HONEYWELL INTERNATIONAL<br />

TOTAL # PLIES:<br />

5 = 5 (otherwise 4 ply)<br />

GLASS FELT TYPE:<br />

TC = Tarred glass<br />

(otherwise tarred<br />

organic felt)<br />

RP-40-5 RP-41-5 RP-60 RP-61 RP-60-5 RP-61-5 RP-50-TC RP-51-TC PM-50<br />

HOT HOT HOT HOT HOT HOT HOT HOT HOT<br />

X X X X X<br />

X X X X<br />

X X X X<br />

0 - 1/2 0 - 1/2 0 - 1/8 0 - 1/8 0 - 1/8 0 - 1/8 0 - 1/4 0 - 1/4 1/4 - 3<br />

5 5 4 4 5 5 4 4 4<br />

1 1 1 1 1<br />

4 5 3 4 4 5 3 4 3<br />

X X X X X X X<br />

X X X X X X<br />

X X X X X X X X X<br />

4 4 4 4 4 4 4 4 4<br />

3 3 3 3 3 3 3 3 3<br />

X X X X X X X X<br />

HOT / HOT / HOT / HOT / HOT / HOT / HOT / HOT / HOT /<br />

COLD COLD COLD COLD COLD COLD COLD COLD COLD<br />

6.5 6.5 6.0 6.5 6.5 6.5 6.0 6.0 6.0<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

99


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME HONEYWELL INTERNATIONAL<br />

2. SPECIFICATION NUMBER LEGEND<br />

(PM) POLY MOP SYSTEMS:<br />

PLY TYPE:<br />

5 = Asphalt Glass<br />

SUBSTRATE:<br />

0 = Nailable<br />

I = Non-nailable<br />

or Insulated<br />

3. SPECIFICATION NUMBER PM-51 PM-50-PM PM-51-PM<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable X X<br />

Insulated<br />

X<br />

Non-nailable<br />

X<br />

6. SLOPE REQUIREMENT (range in inches) 1/4 - 3 1/4 - 3 1/4 - 3<br />

7. NUMBER OF PLIES<br />

Total Plies 4 3 4<br />

Base Sheet 1<br />

Interply(ies) 4 4 4<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt<br />

Modifed Asphalt<br />

Coal Tar X X X<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4 4 4<br />

Slag (lbs/ft²) 3 3 3<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

Aluminum Coating<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS<br />

11B. FLASHING METHOD HOT / HOT / HOT /<br />

COLD COLD COLD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 6.0 6.0 6.0<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

100


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

JOHNS MANVILLE INTERNATIONAL<br />

3, 4, 5 = # of Plies SUBSTRATE: SURFACING:<br />

I = Insulated<br />

G = Gravel<br />

GLASS FELT TYPE: TYPE OF PLY &/or Non-Nailable S =Smooth<br />

PM = Poly Mop Glass Felt G = Fiberglass N = Nailable C = Cap Sheet<br />

(otherwise asphalt glass L = Lightweight Concrete P = Protected<br />

felt)<br />

TOTAL # PLIES:<br />

5 = 5 (otherwise 4 ply)<br />

PM-50-PM-5 PM-51-PM-5 5GNS 4GNS 3GNS 4GIS 3GIS 4GIG 3GIG<br />

HOT HOT HOT HOT HOT HOT HOT HOT HOT<br />

X X X X X<br />

X X X X<br />

X X X X<br />

1/4 - 4 1/4 - 4 0 - 6 0 - 6 0 - 6<br />

5 5 5 4 3 4 3 4 3<br />

1 1 1 1<br />

5 5 4 3 2 4 3 4 3<br />

X X X X X X X X X<br />

X<br />

X<br />

X X X X X X X<br />

4 4 X 400<br />

3 3 300<br />

X X X X X<br />

X X X X X<br />

X X X X X<br />

DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX<br />

HOT / HOT / HOT / HOT / HOT / HOT / HOT / HOT / HOT /<br />

COLD COLD COLD COLD COLD COLD COLD COLD COLD<br />

6.5 6.5 1.6 1.3 1.3 1.4 1.1 6.3 6.0<br />

NONE NONE<br />

404 357 288 404 310 404 310<br />

351 343 247 351 331 351 331<br />

101


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME JOHNS MANVILLE<br />

2. SPECIFICATION NUMBER LEGEND<br />

3, 4, 5 = # of Plies<br />

TYPE OF PLY<br />

G = Fiberglass<br />

3. SPECIFICATION NUMBER 5GNG 4GNG 3GNG<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable X X X<br />

Insulated<br />

Non-nailable<br />

6. SLOPE REQUIREMENT (range in inches)<br />

7. NUMBER OF PLIES<br />

Total Plies 5 4 3<br />

Base Sheet 1 1 1<br />

Interply(ies) 4 3 2<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 400 400 400<br />

Slag (lbs/ft²) 300 300 300<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

Aluminum Coating<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS DYNAFLEX DYNAFLEX DYNAFLEX<br />

11B. FLASHING METHOD HOT / HOT / HOT /<br />

COLD COLD COLD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 6.9 6.6 6.3<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) 2.3<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD 404 357 288<br />

XD 351 343 247<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

102


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

SUBSTRATE:<br />

I = Insulated<br />

&/or Non-Nailable<br />

N = Nailable<br />

L = Lightweight Concrete<br />

SURFACING:<br />

G = Gravel<br />

S =Smooth<br />

C = Cap Sheet<br />

P = Protected<br />

5GLG 4GLG 3GLG 5GIC 4GIC 3GIC 5GNC 4GNC 3GNC<br />

HOT HOT HOT HOT HOT HOT HOT HOT HOT<br />

X X X X X X<br />

X X X<br />

X X X<br />

5 4 3 5 4 3 5 4 3<br />

1 1 1 0 1 1 1<br />

4 3 2 4 3 2 3 2 1<br />

1 1 1 1 1 1<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

400 400 400<br />

300 300 300<br />

X X X X X<br />

DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX<br />

HOT / HOT / HOT / HOT / HOT / HOT / HOT / HOT /<br />

COLD COLD COLD COLD COLD COLD COLD COLD<br />

6.9 6.3 6.0 2.4 2.0 1.8 2.4 2.2 1.8<br />

2.3 3<br />

404 357 288 357 310 268 404 357 288<br />

351 343 247 343 331 247 351 343 247<br />

103


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME KARNAK CORP.<br />

2. SPECIFICATION NUMBER LEGEND<br />

P = Polyester<br />

# of Plies:<br />

21 = 1 Ply<br />

22 = 2 Plies<br />

23 = 3 Plies<br />

24 = 4 Plies<br />

AR = Rubberized Asphalt<br />

3. SPECIFICATION NUMBER P-21 P-22 P-23<br />

4. HOT AND/OR COLD APPLIED COLD COLD COLD<br />

5. DECK TYPE<br />

Nailable X X X<br />

Insulated X X X<br />

Non-nailable X X X<br />

6. SLOPE REQUIREMENT (range in inches) 0 - 6 0 - 6 0 - 6<br />

7. NUMBER OF PLIES<br />

Total Plies 1 2 3<br />

Base Sheet 1 2 1<br />

Interply(ies) 2<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester X X X<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt X X X<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive X X X<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4 4 4<br />

Slag (lbs/ft²) 3 3 3<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt X X X<br />

Coal Tar<br />

Emulsion/Cutback X X X<br />

Aluminum Coating X X X<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules X X X<br />

Cap Sheet<br />

Other (Indicate "X" and describe in Membrane Appendix) X X X<br />

11A. FLASHING MATERIALS<br />

11B. FLASHING METHOD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 0.63 - 1.13 0.72 - 1.32 0.93 - 1.53<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

104


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

KOPPERS INDUSTRIES, INC.<br />

FELT TYPE:<br />

# OF PLIES<br />

2 = Tarred Organic 3 = 3 Ply<br />

4 = Tarred Fiberglass 4 = 4 Ply<br />

DECK TYPE: GP =<br />

1 or 10 = Nailable Tarred fiberglass <strong>to</strong>p-ply<br />

2 or 20= Non-nailable or Insulated over oranic felts<br />

20= Non-nailable or Insulated<br />

90 = Nailable/premium felt<br />

95 = Non-nailable/premium felt<br />

P-24 AR SYSTEM 220-4 210-4 220-4GP 210-4GP 420-4 410-4 495-4<br />

COLD COLD HOT HOT HOT HOT HOT HOT HOT<br />

X X X X X<br />

X X X X X X<br />

X X X X X X<br />

0 - 6 0 - 6 0 - 1/2 0 - 1/2 0 - 1/4 0 - 1/4 0 - 1/4 0 - 1/4 0 - 1/4<br />

4 1 4 4 4 4 4 4 4<br />

1 1 1 1 1<br />

3 4 3 4 3 4 3 4<br />

X X X X X<br />

X X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X X X X X<br />

4 4 4 4 4 4 4 4<br />

3 3 3 3 3 3 3 3<br />

4 4 4 4 4 4 4<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

FIBERGLASS, POLY FIBERGLASS, POLY FIBERGLASS, POLY FIBERGLASS, POLY FIBERGLASS, POLY FIBERGLASS, POLY FIBERGLASS, POLY<br />

FELT / MOD BIT FELT / MOD BIT FELT / MOD BIT FELT / MOD BIT FELT / MOD BIT FELT / MOD BIT FELT / MOD BIT<br />

COLD / COLD / COLD / COLD / COLD / COLD / COLD /<br />

HOT HOT HOT HOT HOT HOT HOT<br />

1.15 - 0.61 0.61 - 1.11 6.1 6.0 6.1 6.1 5.9 6.0 6.0<br />

NONE NONE<br />

105


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME KOPPERS INDUSTRIES, INC.<br />

2. SPECIFICATION NUMBER LEGEND<br />

FELT TYPE:<br />

# OF PLIES<br />

2 = Tarred Organic 3 = 3 Ply<br />

4 = Tarred Fiberglass 4 = 4 Ply<br />

DECK TYPE: GP =<br />

1 or 10 = Nailable Tarred fiber<br />

2 or 20=Non-nailable or Insulated glass <strong>to</strong>p-ply<br />

20= Non-nailable or Insulated over organic<br />

90 = Nailable/premium felt felts<br />

95 = Non-nailable/premium felt<br />

3. SPECIFICATION NUMBER 490-4 495-3 IR-263<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable X X<br />

Insulated<br />

X<br />

Non-nailable<br />

X<br />

6. SLOPE REQUIREMENT (range in inches) 0 - 1/4 0 - 1/4<br />

7. NUMBER OF PLIES<br />

Total Plies 4 3 3<br />

Base Sheet 1 1<br />

Interply(ies) 3 3 2<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X<br />

Organic<br />

X<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt<br />

Modifed Asphalt<br />

Coal Tar X X X<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4 4<br />

Slag (lbs/ft²) 3 3<br />

Crushed Rock (lbs/ft²) 4 4<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

X<br />

Emulsion/Cutback<br />

Aluminum Coating<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS FIBERGLASS, POLY FIBERGLASS, POLY FIBERGLASS, POLY<br />

FELT / MOD BIT FELT / MOD BIT FELT / MOD BIT<br />

11B. FLASHING METHOD COLD / COLD / COLD /<br />

HOT HOT HOT<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 6.0 6.0 2.0<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature)<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED X<br />

106


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

IR = Insulated <strong>Roof</strong> Membrane Assembly<br />

FELT TYPE:<br />

# OF PLIES:<br />

2 = Tarred Organic 3 = 3 Ply<br />

3 = Tarred Glass 4 = 4 Ply<br />

DECK TYPE:<br />

6 = Nailable<br />

7 = Non-nailalbe or Insulated<br />

IR-273 IR-463 IR-473 IR-264 IR-274 IR-464 IR-474 220-3 420-3<br />

HOT HOT HOT HOT HOT HOT HOT HOT HOT<br />

X X X<br />

X X X X<br />

X X X X<br />

0 - 1/4 0 - 1/4 0 - 1/4 0 - 1/4 0 - 1/2 0 - 1/2<br />

3 3 3 4 4 4 4 3 3<br />

1 1 1<br />

3 2 3 3 4 3 4 3 3<br />

X X X<br />

X X X X X X<br />

X X X X X X X X X<br />

4 4<br />

3 3<br />

4 4<br />

X X X X X X X<br />

X X X X<br />

FIBERGLASS, POLY FIBERGLASS, POLY FIBERGLASS, POLY FIBERGLASS, POLY FIBERGLASS, POLY FIBERGLASS, POLY FIBERGLASS, POLY FIBERGLASS, POLY FIBERGLASS, POLY<br />

FELT / MOD BIT FELT / MOD BIT FELT / MOD BIT FELT / MOD BIT FELT / MOD BIT FELT / MOD BIT FELT / MOD BIT FELT / MOD BIT FELT / MOD BIT<br />

COLD / COLD / COLD / COLD / COLD / COLD / COLD / COLD / COLD /<br />

HOT HOT HOT HOT HOT HOT HOT HOT HOT<br />

2.2 2.0 2.1 2.2 2.1 2.1 2.0 5.8 5.7<br />

X X X X X X X<br />

107


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME MALARKEY ROOFING COMPANY<br />

2. SPECIFICATION NUMBER LEGEND<br />

SUFRACE:<br />

M = Mineral<br />

G = Gravel<br />

A = Aluminum<br />

# of Plies<br />

3. SPECIFICATION NUMBER G4-XHX G4-XIX G4-AHX<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable<br />

X<br />

Insulated X X X<br />

Non-nailable<br />

6. SLOPE REQUIREMENT (range in inches) 0 - 3 0 - 3 0 - 3<br />

7. NUMBER OF PLIES<br />

Total Plies 4 4 4<br />

Base Sheet 1<br />

Interply(ies) 4 4 3<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt X X X<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 400 400 400<br />

Slag (lbs/ft²)<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

Aluminum Coating<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS 501or 515 & 601 501or 515 & 601 501or 515 & 601<br />

or 625, or 650 or 625, or 650 or 625, or 650<br />

11B. FLASHING METHOD HOT/TROWEL HOT/TROWEL HOT/TROWEL<br />

GRADE COLD GRADE COLD GRADE COLD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 6.04 6.0 6.0<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

108


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

MFM BUILDING PRODUCTS<br />

BASE/INTERPLY:<br />

CAP SHEET:<br />

A = 515 F = 1000 A = 502<br />

B = 501 H = 500 B = 601<br />

C = 602 I = 506 C = 625<br />

D = 603 X - None D = 650<br />

E = 605 H = 350<br />

X = None<br />

G4-AIX M4-AHA M4-AIA M4-AHH M4-AIH 43-GAW 43-GSW 43-GAC 44-GSC<br />

HOT HOT HOT HOT HOT HOT HOT HOT HOT<br />

X X X X X X X<br />

X X X X X X X<br />

X<br />

X<br />

0 - 3 0 - 3 0 - 3 0 - 3 0 - 3 1/2 - 3 1/2 - 6 1/2 - 3 1/2 - 6<br />

4 4 4 4 4 4 4 3 4<br />

1 2 2 2 2 1 1<br />

3 1 1 1 1 3 3 3 4<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X<br />

400 4 4<br />

X<br />

X<br />

X<br />

X<br />

X X X X<br />

501or 515 & 601 501or 515 & 601 501or 515 & 601 501or 515 & 601 501or 515 & 601<br />

or 625, or 650 or 625, or 650 or 625, or 650 or 625, or 650 or 625, or 650<br />

HOT/TROWEL HOT/TROWEL HOT/TROWEL HOT/TROWEL HOT/TROWEL<br />

GRADE COLD GRADE COLD GRADE COLD GRADE COLD GRADE COLD<br />

6.0 2.2 2.4 2.2 2.4 6 2 6 2<br />

NONE NONE NONE NONE NONE<br />

343 343 293 382<br />

257 257 241 333<br />

109


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME MFM BUILDING PRODUCTS<br />

2. SPECIFICATION NUMBER LEGEND<br />

3. SPECIFICATION NUMBER 42-PAW 52-PSW 52-PSC 52-PAC<br />

4. HOT AND/OR COLD APPLIED HOT HOT HOT HOT<br />

5. DECK TYPE<br />

Nailable X X<br />

Insulated X X<br />

Non-nailable X X<br />

6. SLOPE REQUIREMENT (range in inches) 1/2 - 3 1/2 - 3 1/2 - 3 1/2 - 3<br />

7. NUMBER OF PLIES<br />

Total Plies 3 3 2 2<br />

Base Sheet 1<br />

Interply(ies) 2 2 2 2<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber<br />

X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester X X X<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X X<br />

Modifed Asphalt<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4 4<br />

Slag (lbs/ft²)<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

Aluminum Coating X X<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS<br />

11B. FLASHING METHOD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 5 2 2 6<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature)<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

110


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

SOUTHWESTERN<br />

TAMKO ROOFING PRODUCTS<br />

PETROLEUM<br />

501/601 502/602 503/603 504/604 505/605 507/607 512/612 514/614<br />

COLD HOT HOT HOT HOT HOT HOT HOT HOT<br />

X X X<br />

X X X X X X X<br />

X<br />

12 0 - 3 0 - 3 0 - 3 0 - 3 0 - 3 0 - 3 0 - 1-1/2 0 - 3<br />

3 3 4 4 3 4 5 4 4<br />

1 1<br />

3 3 4 3 4 4 2 3<br />

1 1 1<br />

X<br />

X X X X X X X X<br />

X X X X X X X X X<br />

4 4 4<br />

3 3<br />

X X X<br />

X<br />

X<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

BITUMINOUS AWAPLAN AWAPLAN AWAPLAN AWAPLAN AWAPLAN AWAPLAN AWAPLAN AWAPLAN<br />

TROWEL<br />

HOT ASPHALT HOT ASPHALT HOT ASPHALT HOT ASPHALT HOT ASPHALT HOT ASPHALT HOT ASPHALT HOT ASPHALT<br />

COLD PROC/TORCH COLD PROC/TORCH COLD PROC/TORCH COLD PROC/TORCH COLD PROC/TORCH COLD PROC/TORCH COLD PROC/TORCH COLD PROC/TORCH<br />

1.5 6 2 2 1.5 1.5 2.1 2 6<br />

NONE NONE NONE NONE YES NONE YES NONE NONE<br />

111


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME TAMKO TREMCO<br />

2. SPECIFICATION NUMBER LEGEND<br />

3. SPECIFICATION NUMBER 515/615 516/616 BUR 100<br />

4. HOT AND/OR COLD APPLIED HOT HOT COLD<br />

5. DECK TYPE<br />

Nailable X X X<br />

Insulated<br />

X<br />

Non-nailable<br />

X<br />

6. SLOPE REQUIREMENT (range in inches) 0 - 3 0 - 3 1/8 - 4<br />

7. NUMBER OF PLIES<br />

Total Plies 4 4 3<br />

Base Sheet 1 1<br />

Interply(ies) 3 3<br />

Cap Sheet<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X X<br />

Modifed Asphalt<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4 4.0 - 5.0<br />

Slag (lbs/ft²) 3<br />

Crushed Rock (lbs/ft²) 2.4<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

X<br />

Coal Tar<br />

Emulsion/Cutback X X<br />

Aluminum Coating X X<br />

Vinvl/Vinyl Coating<br />

X<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

X<br />

Cap Sheet<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS AWAPLAN AWAPLAN REINF HYPALON<br />

OR COMPOSITION<br />

11B. FLASHING METHOD HOT ASPHALT HOT ASPHALT COLD<br />

COLD PROC/TORCH COLD PROC/TORCH APPLIED<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 7 1.5 5.7 - 6.7<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD 330<br />

XD 295<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

112


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

W.P. HICKMAN SYSTEMS, INC.<br />

BUR 200 BUR 300 THERM 100 THERM 200 BUR + GLASS<br />

POLYESTER<br />

BUR + GLASS<br />

POLYESTER<br />

PIKA PLY CAP<br />

SHEET<br />

BUR PLUS 505<br />

TAR PLUS<br />

COLD COLD HOT HOT HOT HOT HOT HOT HOT<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

1/8 - 4 1/8 - 4 1/8 - 4 1/8 - 4 1/ 8 - 3 1/8 - 3 1/8 - 3 0 - 1/2 0 - 1/2<br />

3 3 3 3 4 4 3 4 4<br />

1 1 1<br />

3 3 2 3 4<br />

1<br />

X X X X X X<br />

X<br />

X<br />

X X<br />

X X X X X X<br />

X X X X<br />

X X X X<br />

X<br />

X<br />

X<br />

4.0 - 5.0 4.0 - 5.0 4.0 4.0 4 4 4<br />

2.4 2.4<br />

X X X X X<br />

X X X X X<br />

X X X X X<br />

X X X X<br />

X<br />

X<br />

REINF HYPALON REINF HYPALON REINF HYPALON REINF HYPALON<br />

OR COMPOSITION OR COMPOSITION OR COMPOSITION OR COMPOSITION<br />

COLD COLD COLD OR COLD OR<br />

APPLIED APPLIED HOT APPLIED HOT APPLIED<br />

5.7 - 6.7 5.7 - 6.7 1.90 5.25 1.85 6.0 6.0<br />

NONE NONE NONE NONE NONE NONE NONE<br />

390 255 265<br />

400 240 225<br />

113


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME W.P. HICKMAN SYSTEMS, INC.<br />

2. SPECIFICATION NUMBER LEGEND<br />

3. SPECIFICATION NUMBER PERFORMANCE<br />

PLY MS<br />

PERFORMANCE<br />

PLY MS FR<br />

WEATHER PLY MA-<br />

MAFR<br />

4. HOT AND/OR COLD APPLIED COLD COLD COLD<br />

5. DECK TYPE<br />

Nailable X X X<br />

Insulated X X X<br />

Non-nailable X X X<br />

6. SLOPE REQUIREMENT (range in inches) 1/8 - 4 1/8 - 4 1/8 - 4<br />

7. NUMBER OF PLIES<br />

Total Plies 3 3 3<br />

Base Sheet<br />

Interply(ies) 2 2 2<br />

Cap Sheet 1 1 1<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester X X X<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt<br />

Modifed Asphalt<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive X X X<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²)<br />

Slag (lbs/ft²)<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

Coal Tar<br />

Emulsion/Cutback<br />

Aluminum Coating<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet X X X<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS<br />

11B. FLASHING METHOD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 2.25 2.25 2.25<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

114


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

PIKA PLY CAP<br />

SHEET<br />

BUR PLUS<br />

GLASS<br />

BUR PLUS<br />

GLASS<br />

BUR PLUS<br />

POLYESTER<br />

BUR PLUS<br />

POLYESTER<br />

MULTI-PLY<br />

GLASS<br />

MULTI-PLY<br />

GLASS<br />

PERFORMANCE<br />

PLY MS<br />

PERFORMANCE<br />

PLY MSFR<br />

COLD HOT HOT HOT HOT COLD COLD HOT HOT<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

1/8 - 4 1/8 - 3 1/8 - 3 1/8 -3 1/8 - 3 1/8 - 4 1/8 - 4 1/8 - 3 1/8 - 3<br />

3 3 3 3 3 3 3 3 3<br />

2 3 3 3 3 3 3 2 2<br />

1 1 1<br />

X X X X X X X<br />

X X X X X<br />

X X X X X X<br />

X X X X X X X<br />

X<br />

X<br />

4 4 4<br />

X X X<br />

X X X<br />

X X X<br />

X<br />

X X X<br />

2.50 1.85 5.25 1.80 5.25 2.35 5.75 1.85 1.85<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

260 260 275 275 335 335<br />

245 245 255 255 300 300<br />

115


Built-Up <strong>Roof</strong>ing, Part 2 -- Specifications<br />

1. COMPANY NAME W.P. HICKMAN SYSTEMS, INC.<br />

2. SPECIFICATION NUMBER LEGEND<br />

3. SPECIFICATION NUMBER WEATHER PLY MA-<br />

MAFR<br />

BUR PLUS 606<br />

4. HOT AND/OR COLD APPLIED HOT HOT<br />

5. DECK TYPE<br />

Nailable X X<br />

Insulated X X<br />

Non-nailable X X<br />

6. SLOPE REQUIREMENT (range in inches) 1/8 - 3 0 - 6<br />

7. NUMBER OF PLIES<br />

Total Plies 3 4<br />

Base Sheet 1<br />

Interply(ies) 2 3<br />

Cap Sheet 1<br />

8. TYPE OF PLY SHEET<br />

Glass Fiber X X<br />

Organic<br />

Asbes<strong>to</strong>s<br />

Polyester X X<br />

Other<br />

9. INTERPLY ADHESIVE<br />

Asphalt X X<br />

Modifed Asphalt X X<br />

Coal Tar<br />

Elas<strong>to</strong>meric Adhesive<br />

10A. SURFACING -- AGGREGATE<br />

Gravel (lbs/ft²) 4<br />

Slag (lbs/ft²)<br />

Crushed Rock (lbs/ft²)<br />

10B. SURFACING -- SMOOTH<br />

Asphalt<br />

X<br />

Coal Tar<br />

Emulsion/Cutback<br />

Aluminum Coating<br />

X<br />

Vinvl/Vinyl Coating<br />

10C. SURFACING - OTHER<br />

Mineral Granules<br />

Cap Sheet X X<br />

Other (Indicate "X" and describe in Membrane Appendix)<br />

11A. FLASHING MATERIALS<br />

11B. FLASHING METHOD<br />

12. WEIGHT, INCLUDING PLIES (approx. lbs/ft²) 1.85<br />

13. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE<br />

14. TEST RESULTS PER NBS BBS #55<br />

MD = Machine Direction; XD = Cross Direction<br />

14A. Tensile Strength (>200 lb/in @ 0ºF) MD<br />

XD<br />

14B. Thermal Expansion (not > 40x10 –6 / o F@0 o F <strong>to</strong> –30 o F) MD<br />

XD<br />

14C. Thermal Base Shock (not < 100 o F) MD<br />

XD<br />

15. SEE APPENDIX IF CHECKED<br />

116


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME AMERICAN BAKOR BAKOR BAKOR BAKOR BAKOR<br />

LUBRICANTS<br />

2. PRODUCT NAME TIFFANY MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS<br />

G 100s/s G 100p/s G 100 p/p G 180s/s NP180p/p<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier APP SBS SBS SBS SBS SBS<br />

Thickness (mils) 157 80 80 80 90 90<br />

Top Surface MODIFIED SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH<br />

BITUMEN<br />

Reinforcing Material<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

GLASS<br />

NON-WOVEN<br />

GLASS<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

Colors BLACK<br />

Installed Weight (lbs./ft 2 without ballast) 0.87 0.58 0.58 0.58 0.58 0.77<br />

4. KINDS OF FIELD SURFACING REQUIRED NONE GRANULE GRANULE GRANULE GRANULE GRANULE<br />

SHEET SHEET SHEET SHEET SHEET<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD TORCH MOP OR HOT MOP MOP OR MOP OR TORCH<br />

COLD ADHESIVE<br />

COLD ADHESIVE COLD ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method) TORCH MOP/COLD ADHES HOT MOP MOP/COLD ADHES MOP/COLD ADHES TORCH<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber O X X X X X<br />

Mineral Fiber O X X X X X<br />

Polystyrene O O O O O O<br />

Cellular Glass O O O O O O<br />

Phenolic<br />

O<br />

Fiberboard O X X X X X<br />

Perlite O X X X X X<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O O O O<br />

Gypsum O X O X O X O X O X O<br />

Concrete X O O O O O<br />

Wood Plank O O O O O O<br />

Plywood O X X X X X<br />

Existing Built-up Membrane X O O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 0 – 120 20 - 115 20 115 20 - 115 20 - 115 20 - 115<br />

12. FLASHING MATERIAL SAME<br />

MATERIALS<br />

13. FLASHING METHOD TORCH<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin USA GERMANY GERMANY GERMANY GERMANY GERMANY<br />

Manufacture USA CANADA CANADA CANADA CANADA CANADA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1971 1971 1971 1971 1971<br />

Within USA 1981 1985 1985 1988 1988 1988<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA NONE MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS<br />

Within USA MILLIONS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DIRECT DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) NO NO NO NO NO NO<br />

21. SALES INFORMATION, CONTACT: R. G. READ D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR<br />

937/222–2851 800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598<br />

22. TECHNICAL INFORMATION, CONTACT: R. G. READ D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR<br />

937/222–2851 800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598<br />

23. SEE APPENDIX IF CHECKED X X X X X<br />

118


Modified Bitumen Part 1 - General Information<br />

BAKOR BAKOR BAKOR BAKOR BAKOR BAKOR BAKOR BAKOR BAKOR BAKOR<br />

MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS<br />

170 MOP 170 TORCH<br />

NP180p/s G100gMFR GRANULE GRANULE NP180gM NP180gT NP180gM FR NP180gT FR NP250gM NP250gT<br />

SBS SBS SBS SBS SBS SBS SBS SBS SBS SBS<br />

90 148 160 160 160 160 160 160 160 160<br />

SMOOTH GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

GLASS<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

0.57 1.15 1.06 1.06 1.04 1.04 1.08 1.25 1.06 1.06<br />

GRANULE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

SHEET<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

TORCH MOP OR MOP OR TORCH MOP OR TORCH MOP OR TORCH MOP OR TORCH<br />

COLD ADHESIVE COLD ADHESIVE COLD COLD COLD<br />

ADHESIVE ADHESIVE ADHESIVE<br />

TORCH MOP/COLD ADHES MOP/COLD ADHES TORCH MOP/COLD ADHES TORCH MOP/COLD ADHES TORCH MOP/COLDA DHES TORCH<br />

POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X O X O X O X O X O X O X O X O X O X O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X X X X X X X X X X<br />

O O O O O O O O O O<br />

SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS<br />

20 - 115 20 - 115 20 - 115 20 - 115 20 - 115 20 - 115 20 - 115 20 - 115 20 - 115 20 - 115<br />

SAME SAME SAME SAME SAME SAME SAME SAME SAME<br />

MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS<br />

MOP OR MOP OR TORCH MOP OR TORCH MOP OR TORCH MOP OR TORCH<br />

COLD COLD COLD COLD COLD<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

NO NO NO NO NO NO NO NO NO NO<br />

GERMANY GERMANY GERMANY GERMANY GERMANY GERMANY GERMANY GERMANY GERMANY GERMANY<br />

USA CANADA CANADA CANADA CANADA CANADA CANADA CANADA CANADA CANADA<br />

1971 1990 1990 1971 1971 1971 1971<br />

1988 1992 1990 1990 1988 1988 1992 1992 1988 1988<br />

MILLIIONS MILLIIONS MILLIIONS MILLIONS MILLIONS<br />

THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DIRTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DIRTRIBUTORS DIRTRIBUTORS DIRTRIBUTORS DIRTRIBUTORS DIRTRIBUTORS DIRTRIBUTORS<br />

USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA<br />

NO NO NO NO NO NO NO NO NO NO<br />

D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR<br />

800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598<br />

D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR D. TAYLOR<br />

800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598 800/387-9598<br />

X X X X X X X X X X<br />

119


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME BAKOR BAKOR BITEC INC. BITEC INC. BITEC INC. BITEC INC.<br />

2. PRODUCT NAME MODIFIED PLUS MODIFIED PLUS MDA APS-4T APM-4T APM-4.5T<br />

NP250gM FR NP250gT FR<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS APP APP APP APP<br />

Thickness (mils) 160 160 160 160 160 180<br />

Top Surface GRANULE GRANULE MINERAL MODIFIED GRANULES GRANULES<br />

DESIGN BITUMEN<br />

Reinforcing Material<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

SPUNBOND<br />

TYPE 55<br />

SPUNBOND<br />

POLYESTER<br />

SPUNBOND<br />

POLYESTER<br />

SPUNBOND<br />

POLYESTER<br />

Colors<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

VARIOUS BLACK VARIOUS VARIOUS<br />

Installed Weight (lbs./ft 2 without ballast) 1.25 1.25 1.1 0.90 1.1 1.22<br />

4. KINDS OF FIELD SURFACING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X<br />

Reroofing X X X X<br />

6. FIELD LAP JOINT METHOD MOP OR TORCH TORCH TORCH TORCH TORCH<br />

COLD<br />

7. TYPES OF ROOF SYSTEMS:<br />

ADHESIVE<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method) TORCH TORCH TORCH TORCH<br />

Fully Adhered (method) MOP/COLD ADHES TORCH<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber X X O O O O<br />

Mineral Fiber X X O O O O<br />

Polystyrene O O O O O O<br />

Cellular Glass O O O O O O<br />

Phenolic O O O O<br />

Fiberboard X X O O O O<br />

Perlite X X O O O O<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O O O O<br />

Gypsum X O X O O O O O<br />

Concrete O O X O X O X O X O<br />

Wood Plank O O O O O O<br />

Plywood X X O O O O<br />

Existing Built-up Membrane O O X O X O X O X O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) SEE SPECS SEE SPECS NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 20 - 115 20 - 115 40 – 130 40 – 130 40 – 130 40 – 130<br />

12. FLASHING MATERIAL SAME SAME SAME SAME SAME SAME<br />

MATERIALS MATERIALS MATERIAL MATERIAL MATERIAL MATERIAL<br />

13. FLASHING METHOD MOP OR TORCH TORCH TORCH TORCH TORCH<br />

COLD<br />

ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin GERMANY GERMANY ITALY ITALY ITALY ITALY<br />

Manufacture CANADA CANADA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1994 1978 1978 1978<br />

Within USA 1992 1992 1997 1987 1987 1987<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA > 5,000 > 2 MILLION > 2 MILLION 1 MILLION<br />

Within USA THOUSANDS THOUSANDS 5,000 > 2 MILLION > 1 MILLION 58,600<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DIRTRIBUTORS DIRTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS USA & CANADA USA & CANADA 6 6 6 6<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) NO NO YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: D. TAYLOR D. TAYLOR 800/535-8597 800/535-8597 800/535-8597 800/535-8597<br />

800/387-9598 800/387-9598<br />

22. TECHNICAL INFORMATION, CONTACT: D. TAYLOR D. TAYLOR D. ALLEN D. ALLEN D. ALLEN D. ALLEN<br />

800/387-9598 800/387-9598 800/535-8597 800/535–8597 800/535–8597 800/535–8597<br />

23. SEE APPENDIX IF CHECKED X X<br />

OR APM<br />

OR APM<br />

120


Modified Bitumen Part 1 - General Information<br />

BITEC INC. BITEC INC. BITEC INC. BITEC INC. BITEC INC. BITEC INC. BITEC INC. BITEC INC. BITEC INC. BITEC INC.<br />

COMPABASE MDS SPM-4.5T SPM-3.5H SFM-3.5H SPM-4H SPM-4H/250 SPS-3H COMPABASE COMPABASE<br />

FA-2T PS-2H FS-2H<br />

APP SBS SBS SBS SBS SBS SBS SBS SBS SBS<br />

80 160 180 140 140 160 160 120 80 80<br />

MODIFIED MINERAL GRANULES GRANULES GRANULES GRANULES GRANULES MODIFIED MODIFIED MODIFIED<br />

BITUMEN DESIGN BITUMEN BITUMEN BITUMEN<br />

NON-WOVEN<br />

FIBERGLASS<br />

SPUNBOND<br />

TYPE 55<br />

SPUNBOND<br />

POLYESTER 250<br />

SPUNBOND<br />

POLYESTER<br />

NON-WOVEN<br />

FIBERGLASS<br />

SPUNBOND<br />

POLYESTER<br />

SPUNBOND<br />

POLYESTER 250<br />

SPUNBOND<br />

POLYESTER<br />

SPUNBOND<br />

POLYESTER<br />

NON-WOVEN<br />

FIBERGLASS<br />

BLACK VARIOUS VARIOUS VARIOUS VARIOUS VARIOUS VARIOUS MODIFIED BLACK BLACK<br />

0.47 1.1 1.23 1.00 1.00 1.08 1.08 0.73 0.47 0.47<br />

APS 4T, NONE NONE NONE NONE NONE NONE COATING OR SPM OR SPM OR<br />

APP 4T, ASPHALT AND SFM SHEETS SFM SHEETS<br />

APM 4.5T<br />

GRAVEL<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

TORCH HOT MOP OR TORCH HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR<br />

COLD ADHESIVE<br />

COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE<br />

NAIL<br />

TORCH MOP OR ADHES TORCH MOP OR ADHES MOP OR ADHES MOP OR ADHES MOP OR ADHES MOP OR ADHES MOP OR ADHES MOP OR ADHES<br />

POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X O O X O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X O O X O O O O O O O O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

40 – 130 30 – 130 30 – 120 30 – 130 30 – 130 30 – 130 30 – 130 30 – 130 30 – 130 30 – 130<br />

SAME SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

OR SPM-4.5T OR SPF-4.5T OR SPM-4.5T OR SPM-4.5T OR SPM-4.5T OR SPM-4.5T<br />

HOT MOP OR TORCH HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP<br />

OR TORCH OR TORCH OR TORCH OR TORCH OR TORCH OR TORCH<br />

NO NO NO NO NO NO NO NO NO NO<br />

ITALY ITALY ITALY ITALY ITALY ITALY ITALY ITALY ITALY ITALY<br />

USA USA USA USA USA USA USA USA USA USA<br />

1978 1994 1978 1978 1978 1978 1978 1978 1978 1978<br />

1988 1997 1987 1987 1989 1989 1988 1988<br />

100,000 > 5,000 23000 575000 23000<br />

2,000 5,000 7,700 >'2 MILLION >250,000 6,600 22,000 >632,000 4,000 >12,000<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

6 6 6 6 6 6 6 6 6 6<br />

YES YES YES YES YES YES YES YES YES YES<br />

800/535-8597 800/535-8597 800/535-8597 800/535-8597 800/535-8597 800/535-8597 800/535-8597 800/535-8597 800/535-8597 800/535-8597<br />

D. ALLEN D. ALLEN D. ALLEN D. ALLEN D. ALLEN D. ALLEN D. ALLEN D. ALLEN D. ALLEN D. ALLEN<br />

800/535–8597 800/535–8597 800/535–8597 800/535–8597 800/535–8597 800/535–8597 800/535–8597 800/535–8597 800/535–8597 800/535–8597<br />

121


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME BITEC INC. BITEC INC. BITEC INC. BITEC INC. BITEC INC. BITEC INC.<br />

2. PRODUCT NAME COMPAFLASH COMPABASE SFM-3.5H-FR SFM-4H-FR FS-2H PLUS FS-25<br />

BFS-2H FS-2H-FR<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS SBS SBS SBS<br />

Thickness (mils) 80 80 140 160 88 40<br />

Top Surface MODIFIED MODIFIED GRANULES GRANULES MODIFIED MODIFIED<br />

BITUMEN BITUMEN BITUMEN BITUMEN<br />

Reinforcing Material<br />

SPUNBOND<br />

POLYESTER<br />

NON-WOVEN<br />

FIBERGLASS<br />

MAT<br />

NON-WOVEN<br />

FIBERGLASS<br />

MAT<br />

NON-WOVEN<br />

FIBERGLASS<br />

NON-WOVEN<br />

FIBERGLASS<br />

NON-WOVEN<br />

FIBERGLASS<br />

Colors BLACK BLACK VARIOUS VARIOUS BLACK BLACK<br />

Installed Weight (lbs./ft 2 without ballast) 0.47 0.47 1.00 1.05 0.6 0.25<br />

4. KINDS OF FIELD SURFACING REQUIRED ROOF SFM SHEETS NONE NONE SPM OR SPM OR<br />

COATING SPM SHEETS SPM SHEETS<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR<br />

COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method) MOP OR ADHES MOP OR ADHES MOP OR ADHES MOP OR ADHES MOP OR ADHES MOP OR ADHES<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber O O O O O<br />

Mineral Fiber O O O O O<br />

Polystyrene O O O O O<br />

Cellular Glass O O O O O<br />

Phenolic O O O O O<br />

Fiberboard O O O O O<br />

Perlite O O O O O<br />

Polyisocyanurate O O O O O<br />

Polythane O O O O O<br />

Gypsum O O O O O<br />

Concrete X O O O O O<br />

Wood Plank O O O O O<br />

Plywood X O O O O O<br />

Existing Built-up Membrane X O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 30 – 130 30 – 130 30 – 130 30 – 130 30 – 130 30 – 130<br />

12. FLASHING MATERIAL SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL<br />

13. FLASHING METHOD HOT MOP HOT MOP HOT MOP<br />

OR COLD<br />

ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin ITALY ITALY ITALY ITALY ITALY ITALY<br />

Manufacture USA USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1978 1978 1978 1978 1978 1978<br />

Within USA 1989 1988 1989 1989 1988 1988<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA 1,000<br />

Within USA 2,550 >8,000 63,800 >13,000 >65,000 >63,000<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS 6 6 6 6 6 6<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: 800/535-8597 800/535-8597 800/535-8597 800/535-8597 800/535-8597 800/535-8597<br />

22. TECHNICAL INFORMATION, CONTACT: D. ALLEN D. ALLEN D. ALLEN D. ALLEN D. ALLEN D. ALLEN<br />

800/535–8597 800/535–8597 800/535–8597 800/535–8597 800/535–8597 800/535–8597<br />

23. SEE APPENDIX IF CHECKED<br />

122


Modified Bitumen Part 1 - General Information<br />

BITEC INC. CELOTEX CELOTEX CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED<br />

CORP. CORP. ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING<br />

PRODS GROUP PRODS GROUP PRODS GROUP PRODS GROUP PRODS GROUP PRODS GROUP PRODS GROUP<br />

FS-40 CELOTEX APP CELOTEX APP FLINTLASTIC FLINTLASTIC GTA BLACK FLINTLASTIC FLINTLASTIC FLINTLASTIC FLINTLASTIC<br />

4/S 4/M STA PLUS 5.0 GTA DIAMOND AND GTA-FR GTS GMS GMS PREMIUM<br />

CAP SHEET CAP SHEET WHITE DIAMOND<br />

SBS APP APP APP APP APP APP SBS SBS SBS<br />

60 157 157 200 180 160 180 180 160 180<br />

MODIFIED SMOOTH GRANULAR ALUMINUM GRANULE FINE CERAMIC GRANULE GRANULE GRANULE GRANULE<br />

BITUMEN<br />

PARTICLES<br />

NON-WOVEN<br />

FIBERGLASS<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

BLACK BLACK BLACK OR<br />

WHITE<br />

BLACK WHITE / BLACK /<br />

BROWN / TAN/<br />

GRAY / OTHER<br />

BLACK DIAMOND<br />

/ WHITE<br />

DIAMOND<br />

WHITE WHITE WHITE / BLACK /<br />

BROWN / TAN /<br />

OTHER<br />

0.4 1.03 1.13 1 1.05 0.95 1.05 1.22 1.00 1.05<br />

SPM OR COATINGS / NONE REFLECTIVE NONE NONE NONE NONE NONE NONE<br />

SPM S HEETS EMULSIONS COATING<br />

WHITE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT MOP OR TORCH TORCH TORCH TORCH TORCH TORCH TORCH HOT MOP OR HOT MOP OR<br />

COLD ADHESIVE<br />

COLD ADHESVIE COLD ADHESVIE<br />

MOP OR ADHES TORCH TORCH TORCH TORCH TORCH TORCH TORCH MOP/COLD ADH MOP/COLD ADH<br />

POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O X O X O X O X O X O X O X O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

30 – 130 30 – 120 30 – 120 30 – 130 30 – 130 30 – 130 30 – 130 30 – 130 30 – 130 30 – 130<br />

SAME SAME SAME SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH HOT MOP HOT MOP<br />

OR COLD OR COLD<br />

ADHESIVE<br />

NO NO NO NONE NO NO NO NO NO NO<br />

ADHESIVE<br />

ITALY USA USA ITALY UK USA ITALY ITALY USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1978 1965 1963 1978 1978 1972<br />

1988 1983 1983 1997 1986 1987 1996 1986 1980 1989<br />

>100,000 >100,000<br />

>63,000 MILLIONS MILLIONS MILLIONS MILLIONS<br />

DISTRIBUTORS DISTRS,DIRECT DISTRS,DIRECT DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

6 6 6 2 2 2 2 2 2 2<br />

YES YES YES YES YES YES YES YES YES YES<br />

800/535-8597 REG. OFFICE REG. OFFICE SEE SEE SEE SEE SEE SEE SEE<br />

800/CELOTEX 800/CELOTEX APPENDIX APPENDIX APPENDIX APPENDIX APPENDIX APPENDIX APPENDIX<br />

D. ALLEN REG. OFFICE REG. OFFICE<br />

800/535–8597 800/CELOTEX 800/CELOTEX 972/580-5600 972/580-5600 972/580-5600 972/580-5600 972/580-5600 972/580-5600 972/580-5600<br />

X X X X X X X X X<br />

123


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED<br />

ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING<br />

PRODS GROUP PRODS GROUP PRODS GROUP PRODS GROUP PRODS GROUP PRODS GROUP<br />

2. PRODUCT NAME FLINTLASTIC FLINTLASTIC FLINTLASTIC FLINTLASTIC FLINTLASTIC POLY SMS<br />

FR-P FR-P FR PG FR BASE FR CAP BASE SHEET<br />

PREMIUM<br />

SHEET<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS SBS SBS SBS<br />

Thickness (mils) 160 180 180 92 140 120<br />

Top Surface GRANULE GRANULE GRANULE GRANULE GRANULE SAND<br />

Reinforcing Material POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

Colors WHITE WHITE WHITE VARIOUS VARIOUS BLACK<br />

Installed Weight (lbs./ft 2 without ballast) 1.08 1.05 1.00 0.60 0.90 .045<br />

4. KINDS OF FIELD SURFACING REQUIRED NONE NONE NONE CAP SHEET NONE CAP SHEET<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD HOT MOP OR HOT MOP OR HOT MOP OR MECHANICAL, HOT MOP OR MECHANICAL,<br />

COLD ADHESVIE COLD ADHESVIE COLD ADHESVIE HOT MOP OR COLD ADHESIVE HOT MOP OR<br />

7. TYPES OF ROOF SYSTEMS:<br />

COLD ADHESIVE<br />

COLD ADHESIVE<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method) MOP/CLD ADH MECH/MOP/CLD AD<br />

Fully Adhered (method) MOP/COLD ADH MOP/COLD ADH MOP/COLD ADH MOP/COLD ADH MOP/COLD ADH MOP/COLD ADH<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber O O O X O X<br />

Mineral Fiber O O O X O X<br />

Polystyrene O O O X O X<br />

Cellular Glass O O O X O X<br />

Phenolic O O O X O X<br />

Fiberboard O O O X O X<br />

Perlite O O O X O X<br />

Polyisocyanurate O O O X O X<br />

Polythane O O O X O X<br />

Gypsum O O O X O X<br />

Concrete O O O X O X<br />

Wood Plank O O O X O X<br />

Plywood O O O X O X<br />

Existing Built-up Membrane X O X O X O X X O X<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 30 – 130 30 – 130 30 – 130 30 – 130 30 – 130 30 – 130<br />

12. FLASHING MATERIAL SAME SAME SAME ANY SBS SAME ANY SBS<br />

MATERIAL MATERIAL MATERIAL CAP SHEET MATERIAL CAP SHEET<br />

13. FLASHING METHOD HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP<br />

OR COLD OR COLD OR COLD OR COLD OR COLD OR COLD<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA<br />

Within USA 1989 1989 1989 1989 1989 1989<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA 200000 MILLIONS 100000 100000 40000<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS 2 2 2 2 2 2<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: SEE SEE SEE SEE SEE SEE<br />

22. TECHNICAL INFORMATION, CONTACT:<br />

APPENDIX APPENDIX APPENDIX APPENDIX APPENDIX APPENDIX<br />

972/580-5600 972/580-5600 972/580-5600 972/580-5600 972/580-5600 972/580-5600<br />

23. SEE APPENDIX IF CHECKED X X X X X X<br />

124


Modified Bitumen Part 1 - General Information<br />

CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED DANOSA DANOSA DANOSA DANOSA DANOSA DANOSA<br />

ROOFING ROOFING ROOFING ROOFING CARIBBEAN CARIBBEAN CARIBBEAN CARIBBEAN CARIBBEAN CARIBBEAN<br />

PRODS GROUP PRODS GROUP PRODS GROUP PRODS GROUP INC. INC. INC. INC. INC. INC.<br />

BLACK FLEXIGLAS FLEXIGLAS FLINTLASTIC ESTERDAN RM GLASDAN GLASDAN GLASDAN GLASDAN GLASDAN<br />

DIAMOND BASE SHEET PREMIUM STA AL-80 R-36 AL-80-3 RM RM-5<br />

BASE SHEET CAP 960<br />

SBS SBS SBS APP SBS SBS SBS SBS SBS SBS<br />

50 160 160 142 142 130 134 149 173<br />

GRANULE SAND GRANULES ALUMINUM MINERAL ALUMINUM BITUMEN ALUMINUM MINERAL MINERAL<br />

GRANULES GRANULES GRANULES<br />

POLYESTER FIBERGLASS FIBERGLASS POLYESTER POLYESTER GLASS FIBER GLASS FIBER GLASS FIBER GLASS FIBER GLASS FIBER<br />

BLACK BLACK WHITE BLACK WHITE / OTHER ALUMINUM BLACK ALUMINUM WHITE / OTHER WHITE / OTHER<br />

.038 0.30 0.90 0.90 0.99 0.96 0.73 0.80 0.96 1.09<br />

CAP SHEET CAP SHEET NONE REFLECTIVE NONE NONE COATING NONE NONE NONE<br />

COATING<br />

BALALST<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

SELF-ADHESIVE MECHANICAL, HOT MOP OR TORCH HOT MOP OR TORCH HOT MOP OR TORCH HOT MOP OR HOT MOP OR<br />

HOT MOP OR COLD ADHESIVE TORCH OR TORCH OR TORCH OR TORCH OR<br />

COLD ADHESIVE COLD ADHES COLD ADHES COLD ADHES COLD ADHES<br />

MECH.<br />

SELF-ADHERED MOP/CLD ADHS MOP/CLD ADH TORCH MOP OR TORCH MOP OR TORCH MOP OR TORCH MOP OR TORCH MOP OR TORCH MOP OR TORCH<br />

POS DRAIN POS DRAIN POS DRAIN DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL<br />

X X O O X X X X X X<br />

X X O O X X X X X X<br />

X X O O O O O O O O<br />

X X O O X O X O X O X O X O X<br />

X X O O X O X O X O X O X O O<br />

X X O O O O O O O O<br />

X X O O O O O O O X<br />

X X O O O O O O O O<br />

X X O O O O O O O O<br />

X X O O O O O O O O<br />

X X O O X X X X X X<br />

O X O O X O X O X O X O X O<br />

O X O O X O X O X O X O X O<br />

O X O X O X O O O O O O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

30 – 130 30 – 130 30 – 130 30 – 130 14 – 120 14 – 120 14 – 120 14 – 120 14 – 120 14 – 120<br />

FLINTLASTIC ANY FLINTLASTIC SAME SAME SAME SAME GLASDAN SAME SAME SAME<br />

STA, GTA, GMS CAP SHEET MATERIAL MATERIAL MATERIAL OR MATERIAL OR AL-80 OR MATERIAL OR MATERIAL OR MATERIAL OR<br />

GLASDANAL-80 ESTERDAN RM ESTERDAN RM ESTERDAN RM GLASDAN AL-80 ESTERDAN RM<br />

TORCH, MOP TORCH, MOP HOT MOP TORCH HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP<br />

OR COLD OR COLD OR COLD OR TORCH OR TORCH OR TORCH OR TORCH OR TORCH OR TORCH<br />

ADHESIVE ADHESIVE ADHESIVE<br />

NO NO NO NO NO NO NO NO NO NO<br />

USA USA USA ITALY PUERTO RICO PUERTO RICO PUERTO RICO PUERTO RICO PUERTO RICO PUERTO RICO<br />

USA USA USA USA PUERTO RICO PUERTO RICO PUERTO RICO PUERTO RICO PUERTO RICO PUERTO RICO<br />

1978<br />

1989 1990 1997 1980 1979 1979 1979 1988 1988 1988<br />

1,200,000 MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS<br />

50000 MILLIONS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

2 2 2 2 2 2 2 2 2 2<br />

YES YES YES YES YES YES YES YES YES YES<br />

SEE SEE SEE EAST: 927/580-5604 W. RIVERA W. RIVERA W. RIVERA W. RIVERA W. RIVERA W. RIVERA<br />

APPENDIX APPENDIX APPENDIX WEST: 510/606-7434<br />

972/580-5600 972/580-5600 972/580-5600 972/580-5600<br />

X X X X<br />

F. ROMERO F. ROMERO F. ROMERO F. ROMERO F. ROMERO F. ROMERO<br />

125


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME DANOSA DANOSA DANOSA DERMABIT DERMABIT DERMABIT<br />

CARIBBEAN CARIBBEAN CARIBBEAN WATERPROOFING WATERPROOFING WATERPROOFING<br />

INC. INC. INC. INDUSTRIES INDUSTRIES INDUSTRIES<br />

2. PRODUCT NAME ESTERDAN ESTERDAN ESTERDAN DERMABIT DERMABIT ELASPHALT<br />

RM-5 RM-PLUS R-36 4170 4170 4170<br />

SMOOTH GRANULE SMOOTH<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS APP APP SBS<br />

Thickness (mils) 157 196 130 160 160 160<br />

Top Surface MINERAL MINERAL BITUMEN SMOOTH GRANULE SMOOTH<br />

GRANULES GRANULES<br />

Reinforcing Material POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

Colors WHITE / OTHER WHITE / OTHER BLACK BLACK VARIOUS BLACK<br />

Installed Weight (lbs./ft 2 without ballast) 1.09 1.13 0/77 0.88 0.95 0.88<br />

4. KINDS OF FIELD SURFACING REQUIRED NONE NONE COATING NONE NONE COATING<br />

BALLAST<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD HOT MOP OR HOT MOP OR HOT MOP OR TORCH TORCH HOT MOP OR<br />

TORCH OR TORCH OR TORCH OR TORCH<br />

7. TYPES OF ROOF SYSTEMS:<br />

COLD ADHES COLD ADHES COLD ADHES<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method) MOP OR TORCH MOP OR TORCH MOP OR TORCH TORCH TORCH MOP OR TORCH<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber X X X O O O<br />

Mineral Fiber X X X O O O<br />

Polystyrene O O O O O O<br />

Cellular Glass X O X O X O O O O<br />

Phenolic X O X O X O O O O<br />

Fiberboard O O O O O O<br />

Perlite O X O O O O O<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O O O O<br />

Gypsum O O O X X X O<br />

Concrete X X O X X X<br />

Wood Plank X O X O X O O O X O<br />

Plywood X O X O X O O O X O<br />

Existing Built-up Membrane O O O X X X<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 14 – 120 14 – 120 14 - 120 20 – 140 20 – 140 0 – 120<br />

12. FLASHING MATERIAL SAME SAME GLASDAN SAME SAME SAME<br />

MATERIAL OR MATERIAL OR AL-80 OR MATERIAL OR MATERIAL MATERIAL OR<br />

GLASDAN AL-80 GLASDANAL-80 ESTERDAN RM GRANULATED GRANULATED<br />

13. FLASHING METHOD HOT MOP HOT MOP HOT MOP, TORCH TORCH TORCH OR<br />

OR TORCH OR TORCH TORCH OR MOP OR<br />

COLD ADHES<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin PUERTO RICO PUERTO RICO PUERTO RICO SA/ITALY SA/ITALY SA/ITALY<br />

Manufacture PUERTO RICO PUERTO RICO PUERTO RICO SA/ITALY SA/ITALY SA/ITALY<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1976 1976 1976<br />

Within USA 1985 1995 1979 1987 1987 1987<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA MILLIONS MILLIONS 3.5 MILLION 1.5 MILLION 200,000<br />

Within USA THOUSANDS MILLIONS 200,000 100,000<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS 2 2 2 1 1 1<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: W. RIVERA W. RIVERA W. RIVERA G. JERMSTAD G. JERMSTAD G. JERMSTAD<br />

22. TECHNICAL INFORMATION, CONTACT: F. ROMERO F. ROMERO F. ROMERO G. JERMSTAD G. JERMSTAD G. JERMSTAD<br />

COLD<br />

23. SEE APPENDIX IF CHECKED X X X<br />

126


Modified Bitumen Part 1 - General Information<br />

DERMABIT DIBITEN DIBITEN DIBITEN ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY<br />

WATERPROOFING ROOF ROOF ROOF ROOF ROOF ROOF<br />

INDUSTRIES SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS<br />

ELASPHALT DIBITEN DIBITEN DIBITEN ERS - 501 ERS - 503 ERS - 502 ERS - 504 ERS - 505 ERS - 507<br />

4170 POLY/4 POLY/4.5 POLY/5<br />

GRANULE<br />

GRANULAR<br />

SBS APP APP APP SBS/SEBS SBS/SEBS SBS/SEBS SBS/SEBS SBS/SEBS SBS/SEBS<br />

160 160 180 200 130 135 160 160 120 115<br />

GRANULE MODIFIED SLATE FLAKES MODIFIED SMOOTH SMOOTH GRANULES GRANULES GRANULES GRANULES<br />

BITUMEN<br />

BITUMEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

POLYESTER POLYESTER POLYESTER POLYESTER FIBERGLASS FIBERGLASS<br />

VARIOUS BLACK VARIOUS BLACK BLACK BLACK UNLIMITED UNLIMITED UNLIMITED UNLIMITED<br />

0.95 0.90 1.05 1.10 90 100 100 110 90 85<br />

NONE NONE NONE NONE GRAVEL / GRAVEL / NONE NONE NONE NONE<br />

GRANULES GRANULES<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT MOP OR TORCH TORCH TORCH HOT/COLD HOT / COLD HOT/ COLD HOT / COLD HOT / COLD HOT / COLD<br />

TORCH<br />

4 4<br />

MOP OR TORCH TORCH TORCH TORCH X X X X X X<br />

DEAD LEVEL POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

O O O O X X X X X X<br />

O O O O X X X X X X<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O<br />

O O O O X X X X X X<br />

O O O O X X X X X X<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X O O O O O O O O O O<br />

X X O X O X O X O X O X O X O X O X O<br />

X O O O O X O X O X O X O X O X O<br />

X O O O O X O X O X O X O X O X O<br />

X X O X O X O O O O O O O<br />

NONE SEE SPECS SEE SPECS SEE SPECS NONE NONE NONE NONE NONE NONE<br />

0 – 120 40 – 120 40 – 120 40 – 120 40 - 100 40 - 100 40 - 100 40 - 100 40 - 100 40 - 100<br />

SAME SAME DIBITEN SAME SAME SAME SAME SAME SAME SAME<br />

MATERIAL OR MATERIAL POLY/4 MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

GRANULATED<br />

TORCH OR TORCH TORCH TORCH HOT MOP / HOT MOP / HOT MOP / HOT MOP / HOT MOP / HOT MOP /<br />

MOP OR MODIFIED MODIFIED MODIFIED MODIFIED MODIFIED MODIFIED<br />

COLD ADHES BITUMEN BITUMEN BITUMEN BITUMEN BITUMEN BITUMEN<br />

NO NO NO NO YES YES YES YES YES YES<br />

SA/ITALY ITALY ITALY ITALY USA USA USA USA USA USA<br />

SA/ITALY USA USA USA USA USA USA USA USA USA<br />

1976 1968 1968 1968<br />

1987 1978 1978 1978 1988 1988 1988 1988 1988 1988<br />

300,000 10.7 MILLION 900,000 100,000<br />

4.6 MILLION 1.3 MILLION 200,000<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT<br />

1 9 9 9 6 6 6 6 6 6<br />

YES YES YES YES YES YES YES YES YES YES<br />

G. JERMSTAD R. BIANCHI DISTRICT DISTRICT REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE<br />

G. JERMSTAD D. CARL D. CARL D. CARL TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL<br />

SERVICE SERVICE SERVICE SERVICE SERVICE SERVICE<br />

X X X X<br />

127


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY<br />

ROOF ROOF ROOF ROOF ROOF ROOF<br />

SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS<br />

2. PRODUCT NAME ERS - 600 ERS - 601 ERS - 602 ERS - 603 ERS - 604 ERS - 605<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier APP APP SBS/SEBS SBS/SEBS SBS/SEBS SBS/SEBS<br />

Thickness (mils) 160 180 160 170 170 45<br />

Top Surface SMOOTH GRANULES SMOOTH GRANULE GRANULE SMOOTH<br />

Reinforcing Material POLYESTER POLYESTER POLYESTER /<br />

FIBERGLASS<br />

POLYESTER /<br />

FIBERGLASS<br />

POLYESTER /<br />

FIBERGLASS<br />

POLYESTER<br />

Colors BLACK WHITE BLACK UNLIMITED UNLIMITED BLACK<br />

Installed Weight (lbs./ft 2 without ballast) 90 112 105 115 115 80<br />

4. KINDS OF FIELD SURFACING REQUIRED GRAVEL / NONE GRAVEL / NONE NONE GRAVEL /<br />

GRANULES GRANULES GRANULES<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD TORCH TORCH TORCH TORCH TORCH HOT / COLD<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 ) 4 4<br />

Partially Adhered (method)<br />

Fully Adhered (method) X X X X X X<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber X X X X X<br />

Mineral Fiber X X X X X<br />

Polystyrene O O O O O<br />

Cellular Glass O O O O O<br />

Phenolic O O O O O<br />

Fiberboard X X X X X<br />

Perlite X X X X X<br />

Polyisocyanurate O O O O O<br />

Polythane O O O O O<br />

Gypsum O O O O O<br />

Concrete X O X O X O X O X O<br />

Wood Plank X O X O X O X O X O<br />

Plywood X O X O X O X O X O<br />

Existing Built-up Membrane O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 40 -100 40 -100 40 -100 40 - 100 40 - 100<br />

12. FLASHING MATERIAL SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

13. FLASHING METHOD MODIFIED MODIFIED MODIFIED MODIFIED HOT MOP /<br />

BITUMEN BITUMEN BITUMEN BITUMEN MODIFIED<br />

BITUMEN<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA<br />

Manufacture USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA<br />

Within USA 1988 1988 1988 1988 1988<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DIRECT DIRECT DIRECT DIRECT DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 6 6 6 6 6<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

OFFICE OFFICE OFFICE OFFICE OFFICE<br />

22. TECHNICAL INFORMATION, CONTACT: TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL<br />

SERVICE SERVICE SERVICE SERVICE SERVICE<br />

23. SEE APPENDIX IF CHECKED<br />

128


Modified Bitumen Part 1 - General Information<br />

ECOLOGY ECOLOGY ECOLOGY FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE<br />

ROOF ROOF ROOF BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING<br />

SYSTEMS SYSTEMS SYSTEMS PRODUCTS CO. PRODUCTS CO. PRODUCTS CO. PRODUCTS CO. PRODUCTS CO. PRODUCTS CO. PRODUCTS CO.<br />

ERS - 607 ERS - 703 ERS - 601 FR APP160 APP170 APP180 APP180 FR SBS BASE SBS PREMIUM SBS SMOOTH<br />

SHEET BASE SHEET<br />

APP SBS/SEBS APP APP APP APP APP SBS SBS SBS<br />

80 150 180 150 165 170 170 90 90 145<br />

GRANULE ALUMINUM GRANULES SMOOTH SMOOTH GRANULES GRANULES SMOOTH SMOOTH SMOOTH<br />

SHEET<br />

POLYESTER FIBERGLASS POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER FIBERGLASS FIBERGLASS<br />

MAT/SCRIM<br />

GLASS<br />

REINFORCED<br />

WHITE ALUMINUM /<br />

GOLD / COPPER<br />

WHITE BLACK BLACK VARIOUS VARIOUS BLACK BLACK BLACK<br />

80 101 112 0.82 0.90 1.02 1.06 0.54 0.55 0.86<br />

NONE NONE NONE NONE NONE NONE NONE SBS CAP SBS CAP FLOOD COAT /<br />

GRAVEL<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

TORCH HOT / TORCH TORCH TORCH TORCH TORCH TORCH MOP OR MOP OR MOP OR<br />

COLD COLD COLD<br />

HOT MOP HOT MOP<br />

X X X TORCH TORCH TORCH TORCH MOP OR ADHES MOP OR ADHES MOP OR ADHES<br />

X X X X X X X<br />

POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

X X X O O O O X X O<br />

X X X O O O O X X O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X X X O O O O X X O<br />

X X X O O O O X X O<br />

O O O O O O O X O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X O X O X O X X X X X X O<br />

X O X O X O O O O O O O<br />

X O X O X O O O O O O O O<br />

O O O X X X X O O O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

40 - 100 40 - 100 40 - 100 40 - 100 40 - 100 40 - 100 40 - 100 40 - 100 40 - 100 40 - 100<br />

SAME SAME SAME SAME SAME SAME SAME SBS FLASHING SBS FLASHING SBS FLASHING<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL METAL<br />

FLASHING<br />

MODIFIED HOT MOP / MODIFIED TORCH TORCH TORCH TORCH HOT MOP HOT MOP HOT MOP OR<br />

BITUMEN MODIFIED BITUMEN OR COLD OR COLD COLD OR<br />

BITUMEN<br />

YES YES YES NO NO NO NO NO NO NO<br />

COLD ADHES<br />

USA USA USA ITALY ITALY USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1965 1965 1965<br />

1988 1988 1988 1980 1980 1989 1993 1990 1993 1991<br />

MILLIONS MILLIONS MILLIONS<br />

MILLIONS MILLIONS MILLIONS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DIRECT DIRECT DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

6 6 6 5 5 5 5 5 5 5<br />

YES YES YES YES YES YES YES YES YES YES<br />

REGIONAL REGIONAL REGIONAL 800/428–4442 800/428–4442 800/428–4442 800/428–4442 800/428–4442 800/428–4442 800/428–4442<br />

OFFICE OFFICE OFFICE<br />

TECHNICAL TECHNICAL TECHNICAL 800/428–4511 800/428–4511 800/428–4511 800/428–4511 800/428–4511 800/428–4511 800/428–4511<br />

SERVICE SERVICE SERVICE<br />

129


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE<br />

BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING<br />

PRODUCTS CO. PRODUCTS CO. PRODUCTS CO. PRODUCTS CO. PRODUCTS CO. PRODUCTS CO.<br />

2. PRODUCT NAME SBS SBS FR SBS PREMIUM SBS PREMIUM SBS TORCH SBS FLASHING<br />

FR<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS SBS SBS SBS<br />

Thickness (mils) 150 150 160 160 150 150<br />

Top Surface GRANULES GRANULES GRANULES GRANULES GRANULES GRANULES<br />

Reinforcing Material<br />

GLASS<br />

REINFORCED<br />

POLYESTER POLYESTER POLYESTER<br />

GLASS<br />

POLYESTER<br />

GLASS<br />

REINFORCED<br />

POLYESTER<br />

Colors VARIOUS VARIOUS VARIOUS VARIOUS VARIOUS VARIOUS<br />

Installed Weight (lbs./ft 2 without ballast) 0.91 0.91 1.01 1.01 0.93 0.91<br />

4. KINDS OF FIELD SURFACING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD MOP OR MOP OR MOP OR MOP OR TORCH MOP OR<br />

COLD COLD COLD COLD COLD<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method) MOP OR ADHES MOP OR ADHES MOP OR ADHES MOP OR ADHES TORCH MOP OR ADHES<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X X X<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber O O O O O O<br />

Mineral Fiber O O O O O O<br />

Polystyrene O O O O O O<br />

Cellular Glass O O O O O O<br />

Phenolic O O O O O O<br />

Fiberboard O O O O O O<br />

Perlite O O O O O O<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O O O O<br />

Gypsum O O O O O O<br />

Concrete O O O O O O<br />

Wood Plank O O O O O O<br />

Plywood O O O O O O<br />

Existing Built-up Membrane O O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 40 - 100 40 - 100 40 - 100 40 -1 00 40 -100 40 - 100<br />

12. FLASHING MATERIAL SBS FLASHING SEE FLASHING SBS FLASHING SBS FLASHING SAME SAME<br />

MATERIAL MATERIAL<br />

13. FLASHING METHOD HOT MOP OR HOT MOP OR HOT MOP HOT MOP TORCH HOT MOP<br />

COLD OR COLD OR OR COLD OR COLD<br />

COLD ADHES<br />

COLD ADHES<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1965<br />

Within USA 1989 1994 1991 1992 1994 1994<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 5 5 5 5 5 5<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: 800/428–4442 800/428–4442 800/428–4442 800/428–4442 800/428–4442 800/428–4442<br />

22. TECHNICAL INFORMATION, CONTACT: 800/428–4511 800/428–4511 800/428–4511 800/428–4511 800/428–4511 800/428–4511<br />

23. SEE APPENDIX IF CHECKED<br />

130


Modified Bitumen Part 1 - General Information<br />

FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE GAF GAF GAF GAF GAF<br />

BUILDING BUILDING BUILDING BUILDING BUILDING MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS<br />

PRODUCTS CO. PRODUCTS CO. PRODUCTS CO. PRODUCTS CO. PRODUCTS CO. CORP. CORP. CORP. CORP. CORP.<br />

SBS GLASS SBS POLY SBS FR APP PO SBS RUBEROID RUBEROID RUBEROID RUBEROID RUBEROID<br />

TORCH BASE TORCH BASE TORCH GLASS BASE POLYBASE TORCH TORCH TORCH TORCH FR TORCH 1<br />

(SMOOTH) (GRANULE) PLUS<br />

SBS SBS SBS APP SBS APP APP APP APP APP<br />

120 120 175 80 90 160 160 197 197 177<br />

GRANULES GRANULES GRANULES SMOOTH SMOOTH SMOOTH GRANULES GRANULES GRANULES GRANULES<br />

FIBERGLASS<br />

REINFORCED<br />

POLYESTER<br />

REINFORCED<br />

POLYESTER<br />

FIBERGLASS<br />

GLASS<br />

REINFORCED<br />

POLYESTER<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

BLACK BLACK VARIOUS BLACK WHITE/BLACK WHITE/BLACK WHITE/BLACK BLACK / WHITE /<br />

BURNT SIENNA<br />

0.82 0.82 1.2 0.80 1.05 1.25 1.1 1.02<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

TORCH TORCH TORCH TORCH MOP OR TORCH TORCH TORCH TORCH TORCH<br />

COLD<br />

TORCH TORCH TORCH TORCH TORCH<br />

TORCH TORCH TORCH TORCH MOP OR COLD TORCH TORCH TORCH TORCH TORCH<br />

X X X X X X X X X X<br />

POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN MUST DRAIN MUST DRAIN MUST DRAIN MUST DRAIN MUST DRAIN<br />

O O O O X O O O O O<br />

O O O O X O O O O O<br />

O O O O O O O<br />

O O O X X O O O O O<br />

O O O O O O O O O O<br />

O O O O X O O O O O<br />

O O O O X O O O O O<br />

O O O O X O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O X X X O X O X O X O X O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O X OX X O X O X O X O X O<br />

NONE NONE NONE NONE NONE CONTACT GAF CONTACT GAF CONTACT GAF CONTACT GAF CONTACT GAF<br />

40 - 100 40 - 100 40 - 100 30 - 130 30 - 130 40 – 100 40 – 100 40 – 100 40 - 100 40 – 100<br />

SBS FLASHING SBS FLASHING SBS FLASHING SAME SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

TORCH TORCH TORCH TORCH HOT OR TORCH TORCH TORCH TORCH TORCH<br />

COLD<br />

NO NO NO NO NONE YES YES YES YES YES<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1995 1995 1995 1999 2000 1985 1986 1988 1989 1997<br />

THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

5 5 5 5 5 5 5 5 5 5<br />

YES YES YES YES YES YES YES YES YES YES<br />

800/428–4442 800/428–4442 800/428–4442 800/428–4442 800/428–4442 REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

OFFICE OFFICE OFFICE OFFICE OFFICE<br />

800/428–4511 800/428–4511 800/428–4511 800/428–4511 800/428–4511 TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE<br />

800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411<br />

131


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME GAF GAF GAF GAF GAF GAF<br />

MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS<br />

CORP. CORP. CORP. CORP. CORP. CORP.<br />

2. PRODUCT NAME RUBEROID RUBEROID RUBEROID RUBEROID RUBEROID 20 RUBEROID 30<br />

MOP MOP FR MOP MOP 170 FR<br />

PLUS (GRANULE)<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS SBS SBS SBS<br />

Thickness (mils) 197 160 160 160 82 130<br />

Top Surface GRANULES GRANULES GRANULES GRANULES SMOOTH GRANULES<br />

Reinforcing Material POLYESTER POLYESTER POLYESTER POLYESTER FIBERGLASS FIBERGLASS<br />

Colors WHITE / BLACK WHITE / BLACK WHITE / BLACK WHITE / BLACK BLACK WHITE / BLACK<br />

Installed Weight (lbs./ft 2 without ballast) 0.9 0.9 0.9 1.05 0.65 0.92<br />

4. KINDS OF FIELD SURFACING REQUIRED NONE NONE NONE NONE CAP SHEET NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR<br />

COLD COLD COLD COLD COLD COLD<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method) HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP<br />

Fully Adhered (method) HOT MOP/COLD HOT MOP/COLD HOT MOP/COLD HOT MOP/COLD HOT MOP/COLD HOT MOP/COLD<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X X X<br />

8. MINIMUM SLOPE REQUIRED MUST DRAIN MUST DRAIN MUST DRAIN MUST DRAIN MUST DRAIN MUST DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber O O O O O O<br />

Mineral Fiber O O O O O O<br />

Polystyrene<br />

O<br />

Cellular Glass O O O O O O<br />

Phenolic O O O O O O<br />

Fiberboard O O O O X O<br />

Perlite O O O O X O<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O O O O<br />

Gypsum O O O O O O<br />

Concrete O O O O O O<br />

Wood Plank O O O O O O<br />

Plywood O O O O O O<br />

Existing Built-up Membrane O O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) CONTACT GAF CONTACT GAF CONTACT GAF CONTACT GAF CONTACT GAF CONTACT GAF<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 40 - 100 40 - 100 40 - 100 40 - 100 40 - 100 40 - 100<br />

12. FLASHING MATERIAL SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

13. FLASHING METHOD HOT MOP OR MOD HOT MOP OR MOD HOT MOP OR MOD HOT MOP OR MOD HOT MOP OR MOD HOT MOP OR<br />

BIT FLASHING BIT FLASHING BIT FLASHING BIT FLASHING BIT FLASHING FLASHING<br />

CEMENT CEMENT CEMENT CEMENT CEMENT CEMENT<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES NO NO NO<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA<br />

Within USA 1988 1989 1986 1989 1992 1992<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 5 5 5 5 5 5<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE<br />

22. TECHNICAL INFORMATION, CONTACT: TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE<br />

800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411<br />

23. SEE APPENDIX IF CHECKED<br />

132


Modified Bitumen Part 1 - General Information<br />

GAF GAF GAF GAF GAF GAF GAF GAF GAF GAF<br />

MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS<br />

CORP. CORP. CORP. CORP. CORP. CORP. CORP. CORP. CORP. CORP.<br />

RUBEROID RUBEROID RUBEROID RUBEROID RUBEROID RUBEROID RUBEROID MODIFIED ULTRACLAD TRI-PLY<br />

30 FR MOP SBS HW SBS HW SBS HW SBS HW SBS HW CAP SHEET SBS SBS<br />

(SMOOTH) (SMOOTH) (GRANULE) (FR) (PLUS) (PLUS FR) 601+ GRANULE<br />

SBS SBS SBS SBS SBS SBS SBS SBS SBS SBS<br />

130 160 140 145 160<br />

GRANULES SMOOTH SMOOTH GRANULES GRANULES GRANULES GRANULES GRANULES FOIL FACE GRANULE<br />

FIBERGLASS POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER FIBERGLASS FIBERGLASS POLYESTER<br />

WHITE / BLACK BLACK BLACK WHITE / BLACK WHITE / BLACK WHITE / BLACK WHITE / BLACK WHITE COPPER /<br />

ALUMIMUM<br />

0.92 0.9 0.9 1.03<br />

NONE CAP SHEET CAP SHEET NONE NONE NONE NONE NONE NONE NONE<br />

BLACK<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT MOP OR HOT MOP OR TORCH TORCH TORCH TORCH TORCH HOT MOP OR HOT MOP OR HOT MOP<br />

COLD COLD COLD HEAT WELD OR COLD<br />

HOT MOP HOT MOP TORCH TORCH TORCH TORCH TORCH HOT MOP HOT MOP<br />

HOT MOP/COLD HOT MOP/COLD TORCH TORCH TORCH TORCH TORCH HOT MOP/COLD HOT MOP/TORCH HOT MOP/COLD<br />

X X X X X X X X<br />

MUST DRAIN MUST DRAIN MUST DRAIN MUST DRAIN MUST DRAIN MUST DRAIN MUST DRAIN MUST DRAIN MUST DRAIN MUST DRAIN<br />

O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O<br />

O X O O O O O O O O<br />

O X O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O X X O O O<br />

O X X X X O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O X X X X X O O O<br />

CONTACT GAF CONTACT GAF CONTACT GAF CONTACT GAF CONTACT GAF CONTACT GAF CONTACT GAF CONTACT GAF CONTACT GAF CONTACT GAF<br />

40 - 100 40 - 100 40 - 100 40 - 100 40 - 100 40 - 100 40 - 100 40 - 100 40 - 100 40 -100<br />

SAME SAME SAME SAME SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIALS<br />

HOT MOP OR HOT MOP OR MOD TORCH TORCH TORCH TORCH TORCH HOT MOP OR MOD TORCH HOT MOP OR<br />

FLASHING BIT FLASHING BIT FLASHING MOD BIT<br />

CEMENT CEMENT CEMENT FLASHING CEM<br />

NO YES NO NO NO NO NO NO NONE YES<br />

USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1992 1986 1997 1997 1997 1997 1997 1997 1997<br />

DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

5 5 5 5 5 5 5 5 5 5<br />

YES YES YES YES YES YES YES YES YES YES<br />

REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE<br />

TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECHNICAL TECHNICAL<br />

800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411 SERVICES SERVICES<br />

133


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME GAF GAF GARLAND GARLAND GARLAND GARLAND<br />

MATERIALS MATERIALS CO., INC. CO., INC. CO., INC. CO., INC.<br />

CORP. CORP.<br />

2. PRODUCT NAME TRI-PLY TRI-PLY STRESSPLY STRESSPLY STESSPLY STRESSPLY<br />

TP - 4 TP - 4G MINERAL FR FR MINERAL<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier APP APP SBS SBS SBS SBS<br />

Thickness (mils) 160 160 80 135 80 135<br />

Top Surface SMOOTH GRANULE BLACK MINERAL BLACK MINERAL<br />

BEAUTY GRANULES BEAUTY GRANULES<br />

Reinforcing Material POLYESTER POLYESTER DUAL<br />

FIBERGLASS<br />

DUAL<br />

FIBERGLASS<br />

DUAL<br />

FIBERGLASS<br />

FIBERGLASS<br />

Colors WHITE / BLACK WHITE / BLACK BLACK OFF WHITE BLACK OFF WHITE<br />

Installed Weight (lbs./ft 2 without ballast) 0.87 1/03 0.85 1.00 0.85 1.00<br />

4. KINDS OF FIELD SURFACING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD TORCH TORCH HOT MOP HOT MOP HOT MOP HOT MOP<br />

OR COLD OR COLD OR COLD OR COLD<br />

7. TYPES OF ROOF SYSTEMS:<br />

ADHESIVE ADHESIVE ADHESIVE ADHESVIE<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method) TORCH TORCH<br />

Fully Adhered (method) TORCH TORCH MOP/COLD MOP/COLD MOP/COLD MOP/COLD<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X<br />

8. MINIMUM SLOPE REQUIRED MUST DRAIN MUST DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber O O X X X X<br />

Mineral Fiber O O X X X X<br />

Polystyrene O O O O<br />

Cellular Glass O O X X X X<br />

Phenolic O O O O O O<br />

Fiberboard O O X X X X<br />

Perlite O O X X X X<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O O O O<br />

Gypsum O O O O O O<br />

Concrete O O O O O O<br />

Wood Plank O O O O O O<br />

Plywood O O O O O O<br />

Existing Built-up Membrane O O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) CONTACT GAF CONTACT GAF NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 40 -100 40 -100 35 - 120 35 - 120 35 -1 20 35 - 120<br />

12. FLASHING MATERIAL SAME SAME SAME SAME SAME SAME<br />

MATERIALS MATERIALS MATERIAL MATERIAL MATERIAL MATERIAL<br />

13. FLASHING METHOD HOT MOP OR HOT MOP OR HOT MOP HOT MOP HOT MOP HOT MOP<br />

MOD BIT MOD BIT OR COLD OR COLD OR COLD OR COLD<br />

FLASHING CEM FLASHING CEM ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA<br />

Within USA 1978 1989 1986 1989<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS,DIRECT DISTRS,DIRECT DIRECT DIRECT DIRECT DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 5 5 185 185 185 185<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: REGIONAL REGIONAL B. LAMBERT B. LAMBERT B. LAMBERT B. LAMBERT<br />

OFFICE OFFICE 216/641-7500 216/641-7500 216/641-7500 216/641-7500<br />

22. TECHNICAL INFORMATION, CONTACT: TECHNICAL TECHNICAL F. JANOCH F. JANOCH F. JANOCH F. JANOCH<br />

SERVICES SERVICES<br />

23. SEE APPENDIX IF CHECKED<br />

134


Modified Bitumen Part 1 - General Information<br />

GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND<br />

CO., INC. CO., INC. CO., INC. CO., INC. CO., INC. CO., INC. CO., INC. CO., INC. CO., INC. CO., INC.<br />

VERSIPLY VERSIPLY VERSIPLY VERSIPLY PITCHPLY STRESSPLY STRESSPLY STRESSPLY STRESSPLY STRESSPLY<br />

40 60 80 MINERAL SELF ADHERED PLUS PLUS PLUS FR PLUS FR IV<br />

MINERAL MINERAL<br />

SGS SBS SBS SBS NITRILE SEBS/SBS SEBS/SBS SEBS/SBS SEBS/SBS SBS<br />

40 60 80 135 60 80 135 80 135 180<br />

SAND BLACK BLACK MINERAL BLACK MINERAL BLACK MINERAL BLACK<br />

BEAUTY BEAUTY GRANULES BEAUTY GRANULES BEAUTY GRANULES BEAUTY<br />

DUAL<br />

FIBERGLASS<br />

DUAL<br />

FIBERGLASS<br />

DUAL<br />

FIBERGLASS<br />

DUAL<br />

FIBERGLASS<br />

INTERLOCKING<br />

FIBERS<br />

DUAL<br />

FIBERGLASS<br />

DUAL<br />

FIBERGLASS<br />

DUAL<br />

FIBERGLASS<br />

DUAL<br />

FIBERGLASS<br />

DUAL<br />

FIBERGLASS<br />

BLACK BLACK BLACK OFF WHITE BLACK BLACK OFF WHITE BLACK OFF WHITE BLACK<br />

0.90 0.70 0.85 1.00 0.70 0.85 1.00 0.85 1.00 1.40<br />

GRAVEL NONE NONE NONE GRAVEL NONE NONE NONE NONE NONE<br />

OR COATING<br />

OR COATING<br />

X X X X X X XX X X X<br />

X X X X X X X X X<br />

HOT MOP HOT MOP HOT MOP HOT MOP SELF-ADHRED HOT MOP HOT MOP HOT MOP HOT MOP TORCH<br />

OR COLD OR COLD OR COLD OR COLD OR COLD OR COLD<br />

ADHSEIVE ADHSEIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

MOP MOP MOP/COLD MOP/COLD SELF-ADHERED MOP/COLD MOP/COLD MOP/COLD MOP/COLD TORCH<br />

X X X X X X X X X X<br />

POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

X X X X O X X X X O<br />

X X X X O X X X X O<br />

O O O O O O O O O O<br />

X X X X O X X X X O<br />

O O O O O O O O O O<br />

X X X X O X X X X O<br />

X X X X O X X X X O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

35 - 120 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120<br />

SAME SAME SAME SAME SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

HOT MOP HOT MOP HOT MOP HOT MOP SELF- HOT MOP HOT MOP HOT MOP HOT MOP TORCH<br />

OR COLD OR COLD ADHESIVE OR COLD OR COLD OR COLD OR COLD<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1965<br />

1986 1986 1986 1991 1985 1989 1990 1990 1990 1991<br />

DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT<br />

185 185 185 185 185 185 185 185 185 185<br />

YES YES YES YES YES YES YES YES YES YES<br />

B. LAMBERT B. LAMBERT B. LAMBERT B. LAMBERT B. LAMBERT B. LAMBERT B. LAMBERT B. LAMBERT B. LAMBERT B. LAMBERT<br />

216/641-7500 216/641-7500 216/641-7500 216/641-7500 216/641-7500 216/641-7500 216/641-7500 216/641-7500 216/641-7500 216/641-7500<br />

F. JANOCH F. JANOCH F. JANOCH F. JANOCH F. JANOCH F. JANOCH F. JANOCH F. JANOCH F. JANOCH F. JANOCH<br />

135


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND<br />

CO., INC. CO., INC. CO., INC. CO., INC. CO., INC. CO., INC.<br />

2. PRODUCT NAME STRESSPLY HPR TORCH STRESSPLY STRESSPLY STRESSPLY STRESSPLY<br />

IV MINERAL BASE SHEET "E" "E" "E" "E" FR<br />

MINERAL FR MINERAL<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS/SIS/ES SBS/SIS/ES SBS/SIS/ES SBS/SIS/ES<br />

Thickness (mils) 195 120 80 135 80 135<br />

Top Surface MINERAL SBS/SIS/ES BLACK MINERAL BLACK MINERAL<br />

GRANULES 80 BEAUTY GRANULES BEAUTY GRANULES<br />

Reinforcing Material<br />

DUAL<br />

FIBERGLASS<br />

FIBERGLASS<br />

POLYESTER<br />

FIBERGLASS<br />

POLYESTER<br />

FIBERGLASS<br />

POLYESTER<br />

FIBERGLASS<br />

POLYESTER<br />

FIBERGLASS<br />

Colors OFF WHITE BLACK BLACK OFF WHITE BLACK OFF WHITE<br />

Installed Weight (lbs./ft 2 without ballast) 1.60 0.85 0.85 1.00 0.85 1.00<br />

4. KINDS OF FIELD SURFACING REQUIRED NONE SPIV OR NONE NONE NONE NONE<br />

SPIV MIN<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD TORCH TORCH HOT MOP HOT MOP HOT MOP HOT MOP<br />

OR COLD OR COLD OR COLD OR COLD<br />

7. TYPES OF ROOF SYSTEMS:<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method) TORCH TORCH MOP/COLD MOP/COLD MOP/COLD MOP/COLD<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X X X<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber O O X X X X<br />

Mineral Fiber O O X X X X<br />

Polystyrene O O O O O O<br />

Cellular Glass O O X X X X<br />

Phenolic O O O O O O<br />

Fiberboard O O X X X X<br />

Perlite O O X X X X<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O O O O<br />

Gypsum O O O O O O<br />

Concrete O O O O O O<br />

Wood Plank O O O O O O<br />

Plywood O O O O O O<br />

Existing Built-up Membrane O O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120<br />

12. FLASHING MATERIAL SAME SP IV OR SAME SAME SAME SAME<br />

MATERIAL SP IV MINERAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

13. FLASHING METHOD TORCH TORCH HOT MOP HOT MOP HOT MOP HOT MOP<br />

OR COLD OR COLD OR COLD OR COLD<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA<br />

Within USA 1991 1991 1993 1994 1995 1994<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 185 185 185 185 185 185<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: B. LAMBERT B. LAMBERT B. LAMBERT B. LAMBERT B. LAMBERT B. LAMBERT<br />

216/641-7500 216/641-7500 216/641-7500 216/641-7500 216/641-7500 216/641-7500<br />

22. TECHNICAL INFORMATION, CONTACT: F. JANOCH F. JANOCH F. JANOCH F. JANOCH F. JANOCH F. JANOCH<br />

23. SEE APPENDIX IF CHECKED<br />

136


Modified Bitumen Part 1 - General Information<br />

HENRY HENRY HENRY HENRY HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

MODIFIED MODIFIED MODIFIED MODIFIED MODIFIED MODIFIED MODIFIED MODIFIED MODIFIED MODIFIED<br />

PLUS PLUS PLUS PLUS PLUS PLUS PLUS PLUS 170 PLUS 170 PLUS<br />

G100s/s G100p/s G100p/p NP180s/s NP180p/p NP180p/s G100gMFR MOP GRANULE TORCH GRANULE NP180gM<br />

SBS SBS SBS SBS SBS SBS SBS SBS SBS SBS<br />

80 80 88 90 90 90 148 160 160 160<br />

SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH GRANULE GRANULE GRANULE GRANULE<br />

NON-WOVEN<br />

GLASS<br />

NON-WOVEN<br />

GLASS<br />

NON-WOVEN<br />

GLASS<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

GLASS<br />

NON-WOVEN<br />

POLYESER<br />

NON-WOVEN<br />

POLYESER<br />

NON-WOVEN<br />

POLYESTER<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

0.58 0.58 0.58 0.57 0.77 0.57 1.15 1.06 1.06 1.04<br />

GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE NONE NONE NONE NONE<br />

SHEET SHEET SHEET SHEET SHEET SHEET<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

MOP OR HOT MOP TORCH MOP OR TORCH HOT MOP MOP OR MOP OR TORCH MOP OR<br />

COLD COLD COLD COLD COLD<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

MOP/COLD ADHES HOT MOP TORCH MOP/COLD ADHES TORCH HOT MOP MOP/COLD ADHES MOP/COLD ADHES TORCH MOP/COLD ADHES<br />

POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X O X O X O X O X O X O X O X O X O X O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X X X X X X X X X X<br />

O O O O O O O O O O<br />

SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS<br />

20 -115 20 -115 20 -115 20 -115 20 -115 20 -115 20 -115 20 -115 20 -115 20 -115<br />

SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL<br />

MOP OR MOP OR TORCH MOP OR<br />

COLD COLD COLD<br />

ADHESIVE ADHESIVE ADHESIVE<br />

NO NO NO NO NO NO NO NO NO NO<br />

GERMANY GERMANY GERMANY GERMANY GERMANY GERMANY GERMANY GERMANY GERMANY GERMANY<br />

CANADA CANADA CANADA CANADA CANADA CANADA CANADA CANADA CANADA CANADA<br />

1971 1971 1971 1971 1971 1971 1990 1990 1971<br />

1985 1985 1985 1988 1988 1988 1992 1990 1990 1988<br />

MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS<br />

THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA<br />

NO NO NO NO NO NO NO NO NO NO<br />

W. MULLEN W. MULLEN W. MULLEN W. MULLEN W. MULLEN W. MULLEN W. MULLEN W. MULLEN W. MULLEN W. MULLEN<br />

800/523-0268 800/523-0268 800/523-0268 800/523-0268 800/523-0268 800/523-0268 800/523-0268 800/523-0268 800/523-0268 800/523-0268<br />

S. LEONARD S. LEONARD S. LEONARD S. LEONARD S. LEONARD S. LEONARD S. LEONARD S. LEONARD S. LEONARD S. LEONARD<br />

800/486-1278 800/486-1278 800/486-1278 800/486-1278 800/486-1278 800/486-1278 800/486-1278 800/486-1278 800/486-1278 800/486-1278<br />

X X X X X X X X X X<br />

137


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

2. PRODUCT NAME MODIFIED MODIFIED MODIFIED MODIFIED MODIFIED MODIFIED<br />

PLUS PLUS PLUS PLUS PLUS PLUS<br />

NP180gT NP180gM FR NP180gT FR NP250gM NP260gT NP250gM FR<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS SBS SBS SBS<br />

Thickness (mils) 160 160 160 160 160 160<br />

Top Surface GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE<br />

Reinforcing Material NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

Colors<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

Installed Weight (lbs./ft 2 without ballast) 1.04 1.08 1.25 1.06 1.06 1.25<br />

4. KINDS OF FIELD SURFACING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD TORCH MOP OR TORCH MOP OR TORCH MOP OR<br />

COLD COLD COLD<br />

7. TYPES OF ROOF SYSTEMS:<br />

ADHESIVE ADHESIVE ADHESIVE<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method) TORCH MOP/COLD ADHES TORCH MOP/COLD ADHES TORCH MOP/COLD ADHES<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber X X X X X X<br />

Mineral Fiber X X X X X X<br />

Polystyrene O O O O O O<br />

Cellular Glass O O O O O O<br />

Phenolic<br />

Fiberboard X X X X X X<br />

Perlite X X X X X X<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O O O O<br />

Gypsum X O X O X O X O X O X O<br />

Concrete O O O O O O<br />

Wood Plank O O O O O O<br />

Plywood X X X X X X<br />

Existing Built-up Membrane O O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 20 -115 20 -115 20 -115 20 -115 20 -115 20 -115<br />

12. FLASHING MATERIAL SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

13. FLASHING METHOD TORCH MOP OR TORCH MOP OR TORCH MOP OR<br />

COLD COLD COLD<br />

ADHESIVE ADHESIVE ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin GERMANY GERMANY GERMANY GERMANY GERMANY GERMANY<br />

Manufacture CANADA CANADA CANADA CANADA CANADA CANADA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1971 1971<br />

Within USA 1988 1992 1992 1988 1992 1992<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA MILLIONS MILLIONS MILLIONS<br />

Within USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA & CANADA<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) NO NO NO NO NO NO<br />

21. SALES INFORMATION, CONTACT: W. MULLEN W. MULLEN W. MULLEN W. MULLEN W. MULLEN W. MULLEN<br />

800/523-0268 800/523-0268 800/523-0268 800/523-0268 800/523-0268 800/523-0268<br />

22. TECHNICAL INFORMATION, CONTACT: S. LEONARD S. LEONARD S. LEONARD S. LEONARD S. LEONARD S. LEONARD<br />

800/486-1278 800/486-1278 800/486-1278 800/486-1278 800/486-1278 800/486-1278<br />

23. SEE APPENDIX IF CHECKED X X X X X X<br />

138


Modified Bitumen Part 1 - General Information<br />

HENRY HONEYWELL HONEYWELL HONEYWELL HONEYWELL HONEYWELL ICA, INC. ICA, INC. ICA, INC. IKO<br />

COMPANY INTERNATIONAL, INTERNATIONAL, INTERNATIONAL, INTERNATIONAL, INTERNATIONAL, INDUSTRIES<br />

INC. INC. INC. INC. INC.<br />

MODIFIED MILLENNIUM MILLENNIUM MILLENNIUM SPM GPM ICA PREMIUM ICA PREMIUM ICA PREMIUM ARMOURPLAST<br />

PLUS BASE SHEET SMOOTH MOP GMC MILLENNIUM MILLENNIUM APP SMOOTH APP MINERAL APP SLATE CLASSIC<br />

NP250gT FR<br />

SBS SBS SBS SBS SBS SBS APP APP APP APP<br />

160 80 120 150 120 150 160 180 180 150<br />

GRANULE SMOOTH SMOOTH MINERAL SMOOTH MINERAL SMOOTH MINERAL SLATE FLAKES MOD BIT<br />

GRANULES<br />

NON-WOVEN<br />

POLYESTER<br />

FIBERGLASS FIBERGLASS /<br />

SCRIM<br />

FIBERGLASS /<br />

SCRIM<br />

POLYESTER<br />

/ SCRIM<br />

POLYESTER /<br />

SCRIM<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

POLYESTER<br />

WHITE/BLACK<br />

GRAY/BROWN<br />

BLACK BLACK GRAY / BLACK /<br />

LIGHT BEIGE<br />

BLACK GRAY / BLACK /<br />

LIGHT BEIGE<br />

BLACK VARIOUS VARIOUS BLACK<br />

1.25 0.53 0.75 0.87 0.9 1.05 1.05 0.80<br />

NONE CAP SHEET CAP SHEET NONE CAP SHEET NONE NONE NONE NONE ROOF COAT<br />

GRANULES /<br />

GRAVEL<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

TORCH HOT MOP HOT MOP HOT MOP HOT /MOP COLD HOT / MOP COLD TORCH TORCH TORCH TORCH<br />

HEAT WELD HEAT WELD HEAT WELD<br />

COLD COLD COLD<br />

TORCH<br />

TORCH HOT MOP/COLD HOT MOP/COLD HOT MOP/COLD HOT MOP/COLD HOT MOP/COLD COLD ADHES COLD ADHES COLD ADHES TORCH<br />

X X X X X TORCH TORCH TORCH<br />

POS DRAIN NONE NONE NONE NONE NONE POS DRAIN POS DRAIN POS DRAIN 1/4" OR P. DRAIN<br />

X X X X X X O O O O<br />

X X X X X X O O O O<br />

O O O O O<br />

O X X X X X O O O O<br />

O O O O O O O O O<br />

X X X X X X O O O O<br />

X X X X X X O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X O O O O O O O O O O<br />

O X X X X X X X X X<br />

O O O O O O O O O O<br />

X O O O O O O O O O<br />

O O O O O O O O O X<br />

SEE SPECS NONE NONE NONE NONE NONE SEE SPECS SEE SPECS SEE SPECS NONE<br />

20 -115 30 - 100 30 - 100 30 - 100 30 -100 30 - 100 40 – 120 40 – 120 40 – 120 40 – 120<br />

SAME SAME SAME SAME SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL M,ATERIAL MATERIAL MATERIAL MATERIAL<br />

TORCH MILLENNIUM MILLENNIUM MILLENNIUM MILLENNIUM MILLENNIUM TORCH TORCH TORCH TORCH<br />

MASTIC MASTIC MASTIC MASTIC MASTIC<br />

NO NO NO NO NO NO YES YES YES NO<br />

GERMANY USA USA USA USA USA USA USA USA USA /CANADA<br />

CANADA USA USA USA USA USA USA USA USA USA /CANADA<br />

1979<br />

1992 1994 1994 1994 1994 1994 1997 1997 1997 1988<br />

THOUSANDS<br />

DISTRIBUTORS DISTRS. DIRECT DISTRS. DIRECT DISTRS. DIRECT DISTRS. DIRECT DISTRS. DIRECT DISTR,DIRECT DISTR,DIRECT DISTR,DIRECT DISTRIBUTORS<br />

USA & CANADA 6 6 6 6 6 4 4 4<br />

NO YES YES YES YES YES YES YES YES YES<br />

W. MULLEN REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

800/523-0268 OFFICE OFFICE OFFICE OFFICE OFFICE 800/352-7002 800/352-7002 800/352-7002 800/323–7171<br />

S. LEONARD TECHINCAL TECHINCAL TECHINCAL TECHINCAL TECHINCAL<br />

800/486-1278 SERVICES SERVICES SERVICES SERVICES SERVICES 800/352-7002 800/352-7002 800/352-7002 800/323–7171<br />

X X X X<br />

139


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME IKO IKO IKO IKO IKO IKO<br />

INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES<br />

2. PRODUCT NAME ARMOURPLAST MODIFLEX MODIFLEX TORCHFLEX TORCHFLEX TORCHFLEX<br />

GRANULAR MP-180-CAP MP-250-CAP TP-180-CAP TP-250-CAP TP-250-<br />

CAP/5<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier APP SBS SBS SBS SBS SBS<br />

Thickness (mils) 160 138 165 157 157 197<br />

Top Surface GRANULAR GRANULAR GRANULAR GRANULAR GRANULAR GRANULAR<br />

Reinforcing Material POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

Colors VARIOUS VARIOUS VARIOUS VARIOUS VARIOUS VARIOUS<br />

Installed Weight (lbs./ft 2 without ballast) 0.88 0.79 0.96 0.97 0.97 1.19<br />

4. KINDS OF FIELD SURFACING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD TORCH HOT MOP HOT MOP TORCH TORCH TORCH<br />

OR COLD OR COLD<br />

7. TYPES OF ROOF SYSTEMS:<br />

ADHESIVE<br />

ADHESIVE<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method) TORCH TORCH TORCH TORCH<br />

Fully Adhered (method) TORCH HOT MOP/COLD ADHES HOT MOP / COLD ADHES TORCH TORCH TORCH<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED 1/4" OR P. DRAIN 1/4" OR P. DRAIN 1/4" OR P. DRAIN 1/4" OR P. DRAIN 1/4" OR P. DRAIN 1/4" OR P. DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber O O O O O O<br />

Mineral Fiber O O O O O O<br />

Polystyrene O O O O O O<br />

Cellular Glass O O O O O O<br />

Phenolic O O O O O O<br />

Fiberboard O O O O O O<br />

Perlite O O O O O O<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O O O O<br />

Gypsum O O O O O O<br />

Concrete X O O O O O<br />

Wood Plank O O O O O O<br />

Plywood O O O O O O<br />

Existing Built-up Membrane X X X X X X<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120<br />

12. FLASHING MATERIAL SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

13. FLASHING METHOD TORCH HOT MOP HOT MOP TORCH TORCH TORCH<br />

OR COLD OR COLD<br />

ADHESIVE<br />

ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA<br />

Manufacture USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1979 1988 1988 1988 1988 1988<br />

Within USA 1988 1998 1998 1998 1998 1998<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT:<br />

800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171<br />

22. TECHNICAL INFORMATION, CONTACT:<br />

800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171<br />

23. SEE APPENDIX IF CHECKED<br />

140


Modified Bitumen Part 1 - General Information<br />

IKO IKO IKO IKO IKO IKO IKO IKO IKO IKO<br />

INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES<br />

MODIFLEX MODIFLEX MODIFLEX MODIFLEX TORCHFLEX TORCHFLEX TORCHFLEX ARMOURBOND ARMOURBOND ARMOUR<br />

MF-95-SS- BASE MF-95-FS-BASE MP-180-FS- MP-180-SS- TF-95-FF-BASE TF-95-FF- TP-180-FF-BASE 95 180 BRIDGE/PONT<br />

BASE BASE BASE (2.2)<br />

SBS SBS SBS SBS SBS SBS SBS SBS SBS SBS<br />

87 87 87 87 118 87 118 98 118 217<br />

SAND FILM FILM SAND FILM FILM FILM FILM FILM GRANULAR<br />

FIBERGLASS FIBERGLASS POLYESTER POLYESTER FIBERGLASS FIBERGLASS FIBERGLASSQ FIBERGLASS POLYESTER POLYESTER<br />

BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK<br />

0.53 0.52 0.51 0.51 0.74 0.54 0.71 0.58 0.69 1.33<br />

MODIFLEX TORCHFLEX TORCHFLEX MODIFLEX TORCHFLEX TORCHFLEX TORCHFLEX ARMOURPLAST ARMOURPLAST NONE<br />

CAP CAP CAP CAP CAP CAP CAP OR TORCHFLEX OR TORCHFLEX<br />

CAP<br />

CAP<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT MOP HOT MOP HOT MOP HOT MOP TORCH TORCH TORCH TORCH TORCH TORCH<br />

OR COLD TORCH TORCH OR COLD<br />

ADHESIVE<br />

ADHESIVE<br />

MOP OR ADHES. MOP, TORCH MOP, TORCH MOP OR ADHES. TORCH TORCH TORCH TORCH TORCH TORCH<br />

1/4" OR P. DRAIN 1/4" OR P. DRAIN 1/4" OR P. DRAIN 1/4" OR P. DRAIN 1/4" OR P. DRAIN 1/4" OR P. DRAIN 1/4" OR P. DRAIN 1/4" OR P. DRAIN 1/4" OR P. DRAIN 1/4" OR P. DRAIN<br />

X X X OX X X X O O O<br />

X X X X X X X O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X OX X X X X X X X O<br />

O O O O O O O O O O<br />

O O O O O O O X X O<br />

X X X X X X X O O X<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

40 - 120 40 - 120 40 - 120 40 - 120 40 - 120 40 - 120 40 - 120 40 - 120 40 - 120 40 - 120<br />

SAME SAME SAME SAME SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

HOT MOP HOT MOP HOT MOP HOT MOP TORCH TORCH TORCH SELF-ADHERE SELF-ADHERE TORCH<br />

OR OR OR OR<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

NO NO NO NO NO NO NO NO NO NO<br />

USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA<br />

USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA USA/CANADA<br />

1988 1988 1988 1988 1988 1988 1988 1988 1988 1988<br />

1998 1998 1998 1998 1998 1998 1998 1998 1998 1998<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

YES YES YES YES NO YES YES YES YES YES<br />

800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171<br />

800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171 800/323–7171<br />

141


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME IKO IKO IKO JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE<br />

INDUSTRIES INDUSTRIES INDUSTRIES INTERNATIONAL INTERNATIONAL INTERNATIONAL<br />

INC. INC. INC.<br />

2. PRODUCT NAME ARMOURGARD ARMOUR MF-95-CAP DYNAKAP DYNAKAP FR DYNAGLAS<br />

ICE & WATER TREAD 15<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS SBS SBS SBS<br />

Thickness (mils) 71 275 138 160 160 150<br />

Top Surface SAND GRANULES GRANULES GRANULE GRANULE GRANULE<br />

Reinforcing Material FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS &<br />

POLYESTER<br />

FIBERGLASS &<br />

POLYESTER<br />

FIBERGLASS<br />

Colors GRAY GREEN CHARCOAL<br />

GRAY<br />

VARIOUS WHITE / BLACK WHITE / BLACK WHITE / BLACK<br />

Installed Weight (lbs./ft 2 without ballast) 0.32 1.21 0.84 1.10 1.10 0.88<br />

4. KINDS OF FIELD SURFACING REQUIRED SHINGLES NONE NONE NONE NONE NONE<br />

MOP OR TORCH<br />

CAP<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD SELF-ADHERE N/A HOT MOP HOT MOP HOT MOP HOT MOP<br />

OR COLD OR COLD OR COLD OR COLD<br />

7. TYPES OF ROOF SYSTEMS:<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method) TORCH HOT OR COLD HOT OR COLD HOT OR COLD<br />

Protected <strong>Roof</strong> Membrane Assembly X X<br />

8. MINIMUM SLOPE REQUIRED 1/4" OR P. DRAIN 1/8" 1/8" 1/8"<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber O O X X X<br />

Mineral Fiber O O O O O<br />

Polystyrene O O O O O<br />

Cellular Glass O O O O O<br />

Phenolic O O<br />

Fiberboard O O X X X<br />

Perlite O O X X X<br />

Polyisocyanurate O O O O O<br />

Polythane O O O O O<br />

Gypsum O O X X X<br />

Concrete X O O X X X<br />

Wood Plank O O X X X<br />

Plywood X O O X X X<br />

Existing Built-up Membrane O X O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 40 - 120 40 - 120 40 - 120 40 - 120 40 - 120<br />

12. FLASHING MATERIAL SAME MODIFLEX DYNAFLEX DYNAFLEX DYNAFLEX<br />

MATERIAL<br />

MP-180 CAP<br />

13. FLASHING METHOD SELF-ADHERE HOT MOP HOT MOP OR HOT MOP OR HOT MOP OR<br />

OR COLD MEMBRANE MEMBRANE MEMBRANE<br />

ADHESIVE FLASH CEMENT FLASH CEMENT FLASH CEMENT<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin USA/CANADA USA/CANADA USA/CANADA USA USA USA<br />

Manufacture USA/CANADA USA/CANADA USA/CANADA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1988 1999 1999<br />

Within USA 1998 1999 1999 1983 1986 1987<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA MILLIONS MILLIONS MILLIONS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS 5 5 5<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) NO NO YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: DIST OFFICE DIST OFFICE DIST OFFICE<br />

800/323–7171 800/323–7171 800/323–7171<br />

22. TECHNICAL INFORMATION, CONTACT: GUARANTEE GUARANTEE GUARANTEE<br />

800/323–7171 800/323–7171 800/323–7171 SERVICES SERVICES SERVICES<br />

23. SEE APPENDIX IF CHECKED<br />

142


Modified Bitumen Part 1 - General Information<br />

JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE<br />

INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL<br />

INC. INC. INC. INC. INC. INC. INC. INC. INC. INC.<br />

DYNAPLY DYNAGLAS FR DYNALASTIC DYNALASTIC DYNALASTIC DYNAGLAS DYNABASE DYNALASTIC DYNALASTIC DYNAMAX<br />

250 180 180 FR 30 FR 180 S 250 FR<br />

SBS SBS SBS SBS SBS SBS SBS SBS SBS SBS<br />

125 160 158 150 150 140 100 118 160 160<br />

SAND GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE<br />

FIBERGLASS &<br />

POLYESTER<br />

FIBERGLASS POLYESTER POLYESTER POLYESTER FIBERGLASS FIBERGLASS POLYESTER POLYESTER FIBERGLASS<br />

POLYESTER<br />

BLACK WHITE / BLACK WHITE / BLACK WHITE / BLACK WHITE / BLACK WHITE / BLACK BLACK BLACK WHITE / BLACK WHITE / BLACK<br />

0.78 0.88 0.96 0.88 0.88 0.90 0.60 0.8 1.06 1.16<br />

ASPHALT AND NONE NONE NONE NONE NONE CAP SHEET CAP SHEET NONE NONE<br />

GRAVEL<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP<br />

OR COLD OR COLD OR COLD OR COLD OR COLD OR COLD OR COLD OR COLD OR COLD OR COLD<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

HOT OR COLD HOT OR COLD HOT OR COLD HOT OR COLD HOT OR COLD HOT OR COLD HOT OR COLD HOT OR COLD HOT OR COLD HOT OR COLD<br />

X X X X X X<br />

1/8" 1/8" 1/8" 1/8" 1/8" 1/8" 1/8" 1/8" 1/8" 1/8"<br />

X X X X X X X X X X<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

O O O O O O O O O O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

40 - 120 40 - 120 40 - 120 40 - 120 40 - 120 40 - 120 40 - 120 40 - 120 40 - 120 40 - 120<br />

DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX DYNAFLEX<br />

HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR<br />

MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE COLD FLASHING MEMBRANE MEMBRANE MEMBRANE MEMBRANE<br />

FLASH CEMENT FLASH CEMENT FLASH CEMENT FLASH CEMENT FLASH CEMENT CEMENT FLASH CEMENT FLASH CEMENT FLASH CEMENT FLASH CEMENT<br />

NO NO NO NO NO NO NO NO NO NO<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1987 1988 1995 1993 1994 1993 1987 1979 1996 1995<br />

>100,000 >100,000 >100,000<br />

100,OOO MILLIONS 10,000 THOUSANDS THOUSANDS THOUSANDS MILLIONS THOUSANDS THOUSANDS THOUSANDS<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

5 5 5 5 5 5 5 5 5 5<br />

YES YES YES YES YES YES YES YES YES YES<br />

DIST OFFICE DIST OFFICE DIST OFFICE DIST OFFICE DIST OFFICE DIST OFFICE REGIONAL REGIONAL REGIONAL REGIONAL<br />

OFFICE OFFICE OFFICE OFFICE<br />

GUARANTEE GUARANTEE GUARANTEE GUARANTEE GUARANTEE GUARANTEE GUARANTEE GUARANTEE GUARANTEE GUARANTEE<br />

SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES<br />

143


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE<br />

INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL<br />

INC. INC. INC. INC. INC. INC.<br />

2. PRODUCT NAME DYNAMAX FR APPEX 4S TRICOR-M FR TRICOR BICOR APPEX 4.5M<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS APP APP APP APP APP<br />

Thickness (mils) 160 160 180 160 160 160<br />

Top Surface GRANULE SMOOTH MINERAL SMOOTH SMOOTH MINERAL<br />

Reinforcing Material<br />

FIBERGLASS<br />

POLYESTER<br />

POLYESTER<br />

LAMINATED<br />

GLASS FIBER /<br />

POLYESTER<br />

LAMINATED<br />

GLASS FIBER /<br />

POLYESTER<br />

FIBERGLASS<br />

POLYESTER<br />

Colors WHITE / BLACK BLACK GRAY / WHITE BLACK BLACK GRAY / WHITE<br />

Installed Weight (lbs./ft 2 without ballast) 1.16 0.90 1.0 0.95 0.95 1.05<br />

KINDS OF FIELD SURFACING REQUIRED NONE ALUMINUM NONE ALUMINUM ALUMINUM NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD HOT MOP TORCH TORCH TORCH TORCH TORCH<br />

OR COLD<br />

ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 ) 10 10<br />

Partially Adhered (method)<br />

Fully Adhered (method) HOT OR COLD TORCH TORCH TORCH/COLD TORCH/COLD TORCH<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X X<br />

8. MINIMUM SLOPE REQUIRED 1/8" POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber X O O O O O<br />

Mineral Fiber O O O O O O<br />

Polystyrene O O O O O O<br />

Cellular Glass O O O O O O<br />

Phenolic O O O O O<br />

Fiberboard X O O O O O<br />

Perlite X O O O O O<br />

Polyisocyanurate O O O O O O<br />

Polythane<br />

O<br />

Gypsum X O X O X O X O O<br />

Concrete X X O O O O X O<br />

Wood Plank X O O O O O<br />

Plywood X O O O O O<br />

Existing Built-up Membrane O X O X O X O X O X O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 40 - 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120<br />

12. FLASHING MATERIAL DYNAFLEX SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL OR<br />

13. FLASHING METHOD HOT MOP OR TORCH TORCH TORCH TORCH TORCH<br />

MEMBRANE<br />

FLASH CEMENT<br />

APPEX 45<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1967<br />

Within USA 1995 1979 1994 1994 1994 1994<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA 83,400,000<br />

Within USA THOUSANDS 8,000,000 THOUSANDS THOUSANDS THOUSANDS >100,000<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS 5 5 5 8 8 8<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE<br />

22. TECHNICAL INFORMATION, CONTACT: GUARANTEE GUARANTEE GUARANTEE GUARANTEE GUARANTEE GUARANTEE<br />

SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES<br />

23. SEE APPENDIX IF CHECKED<br />

144


Modified Bitumen Part 1 - General Information<br />

JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE KOPPERS KOPPERS KOPPERS KOPPERS KOPPERS KOPPERS<br />

INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES<br />

INC. INC. INC. INC. INC. INC. INC. INC. INC. INC.<br />

APPEX 4.5M DYNAWELD DYNAWELD BASE DYNACLAD 2040 2040 2041 2041 2041 2045<br />

FR CAP FR M S M S MFR M<br />

APP SBS SBS SBS APP APP SBS SBS SBS SBS<br />

160 160 120 160 4.5 MM 4.0 MM 3.8 MM 3.0 MM 3.8 MM 4.0 MM<br />

MINERAL GRANULES SAND METAL FOIL GRANULES SMOOTH GRANULES SMOOTH GRANUELES GRANULES<br />

POLYESTER GLASS GLASS GLASS SCRIM NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

NON-WOVEN<br />

POLYESTER<br />

GRAY / WHITE WHITE / BLACK BLACK ALUMINUM<br />

COPPER<br />

1.12<br />

WHITE BLACK WHITE / BLACK BLACK1 WHITE WHITE<br />

NONE NONE ASPHALT NONE NONE ALUMINUM NONE ALUMINUM NONE NONE<br />

GRAVEL COATING COATING<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

TORCH TORCH TORCH TORCH TORCH TORCH MOP / MOP / MOP / MOP /<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

TORCH TORCH TORCH TORCH TORCH TORCH MOP/ADHESIVE MOP/ADHESIVE MOP/ADHESIVE MOP/ADHESIVE<br />

X<br />

POS DRAIN 1/8" 1/8" 1/8" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4"<br />

O O O O X X X X X X<br />

O O O O X X X X X X<br />

O O O O<br />

O O O O X X X X X X<br />

O<br />

O O O O X X X X X X<br />

O X X X O O X X X X X X<br />

O O O O<br />

O O O<br />

O X O O X X X X X X<br />

X O X X O X O X X X X X X<br />

O O O O X X X X X X<br />

O O O O X X X X X X<br />

X O X X X O<br />

NONE NONE NONE NONE<br />

40 - 120 40 - 120 40 - 120 40 - 120 12 - 150 12 - 150 -10 - 150 -10 - 150 -10 - 150 -10 - 150<br />

SAME SAME DYNAWELD SAME 2040S 2040S FIBERGLASS FIBERGLASS FIBERGLASS POLYESTER<br />

MATERIAL OR MATERIAL OR CAP FR OR MATERIAL 2040M 2040M FELT, FELT, FELT, FELT,<br />

APPEX 45 DYNACLAD DYNACLAD 2041M 2041M, S 2041S, M 2045 M<br />

TORCH TORCH TORCH TORCH TORCH TORCH MOP / MOP / MOP / MOP /<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

NO NO NO NO NO NO NO NO NO NO<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1994 1999 1999 1995<br />

THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTOR DISTRIBUTOR DISTRIBUTOR DISTRIBUTOR DISTRIBUTOR DISTRIBUTOR<br />

8 8 8 8 4 4 4 4 4 4<br />

YES YES YES YES YES YES YES YES YES YES<br />

REGIONAL REGIONAL REGIONAL REGIONAL 800/558-2706 800/558-2706 800/558-2706 800/558-2706 800/558-2706 800/558-2706<br />

OFFICE OFFICE OFFICE OFFICE<br />

GUARANTEE GUARANTEE GUARANTEE GUARANTEE 800/468-9629 800/468-9629 800/468-9629 800/468-9629 800/468-9629 800/468-9629<br />

SERVICES SERVICES SERVICES SERVICES<br />

145


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME KOPPERS MALARKEY MALARKEY MALARKEY MALARKEY MALARKEY<br />

INDUSTRIES ROOFING ROOFING ROOFING ROOFING ROOFING<br />

INC. CO. CO. CO. CO. CO.<br />

2. PRODUCT NAME 2045 APP APP 160 APP 161 APP 162 PREMIUM SBS<br />

MFR 159 SMOOTH MINERAL MINERAL 601<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS APP APP APP APP SBS<br />

Thickness (mils) 4.0 MM 159 160 160 160 120<br />

Top Surface GRANULES SMOOTH SMOOTH GRANULE GRANULE GRANULE<br />

Reinforcing Material<br />

NON-WOVEN<br />

POLYESTER<br />

FIBERGLASS POLYESTER POLYESTER POLYESTER POLYGLASS<br />

Colors WHITE BLACK BLACK WHITE WHITE WHITE / BLACK /<br />

VARIOUS<br />

Installed Weight (lbs./ft 2 without ballast)<br />

KINDS OF FIELD SURFACING REQUIRED EMULSION / EMULSION / NONE NONE NONE<br />

GRANULE / GRANULE /<br />

ALUMINUM<br />

ALUMINUM<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD MOP / TORCH TORCH TORCH TORCH HOT / COLD<br />

ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 ) 10 10<br />

Partially Adhered (method)<br />

Fully Adhered (method) MOP / ADHESIVE TORCH TORCH TORCH TORCH HOT/COLD<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X<br />

8. MINIMUM SLOPE REQUIRED 1/4" TO DRAIN TO DRAIN TO DRAIN TO DRAIN TO DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber X O O O O X<br />

Mineral Fiber X O O O O X<br />

Polystyrene O O O O O<br />

Cellular Glass X O O O O O<br />

Phenolic<br />

Fiberboard X O O O O X<br />

Perlite X O O O O X<br />

Polyisocyanurate O O O O X O<br />

Polythane O O O O X O<br />

Gypsum X X O X O X O X O X<br />

Concrete X X X X X X<br />

Wood Plank X O O O O X<br />

Plywood X O O O O X<br />

Existing Built-up Membrane X O X O X O X O X O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) -10 - 150 20 20 20 20<br />

12. FLASHING MATERIAL POLYLESTER SAME SAME SAME SAME SAME<br />

FELT, MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

2045 MFR<br />

13. FLASHING METHOD HOT / TORCH TORCH TORCH TORCH HOT / COLD<br />

ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1961 1960 1960 1960 1982<br />

Within USA 1961 1990 1990 1990 1982<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTOR DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS 4 100+ 100 + 100 + 100 + 100 +<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: 800/558-2706 G MALARKEY G MALARKEY G MALARKEY G MALARKEY G MALARKEY<br />

22. TECHNICAL INFORMATION, CONTACT: 800/468-9629 J. KOUBA J. KOUBA J. KOUBA J. KOUBA J. KOUBA<br />

D.DEGROOT D. DEGROOT D. DEGROOT D. DEGROOT D. DEGROOT<br />

23. SEE APPENDIX IF CHECKED<br />

146


Modified Bitumen Part 1 - General Information<br />

MALARKEY MALARKEY PERFORMANCE PERFORMANCE PERFORMANCE PERFORMANCE PERFORMANCE PERFORMANCE PERFORMANCE PERFORMANCE<br />

ROOFING ROOFING ROOF ROOF ROOF ROOF ROOF ROOF ROOF ROOF<br />

CO. CO. SYSTEMS INC. SYSTEMS INC. SYSTEMS INC. SYSTEMS INC. SYSTEMS INC. SYSTEMS INC. SYSTEMS INC. SYSTEMS INC.<br />

PARAGON SBS PANOPLY DERBIGUM-XPS DERBICOLOR DERBIGUM DERBICOLOR DERBIGUM GP DERBICOLOR DERBIGUM DERBICOLOR<br />

625 SBS 650 XPS XPS FR XPS FR GP GP FR GP FR<br />

SBS SBS APP APP APP APP APP APP APP APP<br />

125 150 160 160 160 180 150 180 160 180<br />

GRANULE GRANULE MODIFIED MINERAL MODIFIED MINERAL MODIFIED MINERAL MODIFIED MINERAL<br />

BITUMEN BITUMEN BITUMEN BITUMEN<br />

FIBERGLASS FIBERGLASS FIBRGLS LAMIN<br />

& POLYESTER<br />

SCRIM<br />

WHITE / BLACK /<br />

VARIOUS<br />

WHITE / BLACK /<br />

VARIOUS<br />

FIBRGLS LAMIN<br />

& POLYESTER<br />

SCRIM<br />

FIBRGLS LAMIN<br />

& POLYESTER<br />

SCRIM<br />

FIBRGLS LAMIN<br />

& POLYESTER<br />

SCRIM<br />

FIBERGLASS<br />

MAT &<br />

POLYESTER<br />

SCRIM<br />

FIBERGLASS<br />

MAT &<br />

POLYESTER<br />

SCRIM<br />

FIBERGLASS<br />

MAT &<br />

POLYESTER<br />

SCRIM<br />

FIBERGLASS<br />

MAT &<br />

POLYESTER<br />

SCRIM<br />

BLACK VARIOUS BLACK VARIOUS BLACK VARIOUS BLACK VARIOUS<br />

0.95 1.08 0.95 1.08 .93 1.06 .93 1.06<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT / COLD HOT / COLD TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH<br />

HOT/COLD HOT/COLD TRCH OR MASTIC TRCH OR MASTIC TRCH OR MASTIC TRCH OR MASTIC TRCH OR MASTIC TRCH OR MASTIC TRCH OR MASTIC TRCH OR MASTIC<br />

X X X X X X<br />

TO DRAIN TO DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

X X O O O O O O O O<br />

X X O O O O O O O O<br />

O O O O O<br />

X O X O O O O O O O O O<br />

O O O<br />

X X O O O O O O O O<br />

X X O O O O O O O O<br />

X O X O O O O O O O O O<br />

X O X O O O O O O O O O<br />

X X O O O O O O O O<br />

X X X O X O O X O X O O<br />

X X O O O O O O O O<br />

X O X O O O O O O O O<br />

X X O X O X O X O X O X O X O X O X O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120<br />

SAME SAME SAME SAME SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

HOT / COLD HOT / COLD TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH<br />

OR OR OR OR OR OR OR OR<br />

MASTIC MASTIC MASTIC MASTIC MASTIC MASTIC MASTIC MASTIC<br />

NO NONE NO NO NO NO NO NO NO NO<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1993 1992 1993 1993 1994 1994 1993 1993 1994 1994<br />

DISTRIBUTORS DISTRIBUTORS DISTR/DIRECT DISTR/DIRECT DISTR/DIRECT DISTR/DIRECT DISTR/DIRECT DISTR/DIRECT DISTR/DIRECT DISTR/DIRECT<br />

100 + 100+<br />

YES YES YES YES YES YES YES YES YES YES<br />

G MALARKEY G. MALARKEY CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE<br />

800/727–9872 800/727–9872 800/727–9872 800/727–9872 800/727–9872 800/727–9872 800/727–9872 800/727–9872<br />

J. KOUBA J. KOUBA K. HUNT K. HUNT K. HUNT K. HUNT K. HUNT K. HUNT K. HUNT K. HUNT<br />

D. DEGROOT D. DEGROOT 800/727–9872 800/727–9872 800/727–9872 800/727–9872 800/727–9872 800/727–9872 800/727–9872 800/727–9872<br />

X X X X X X X X<br />

147


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME PERFORMANCE PERFORMANCE POLYGLASS POLYGLASS POLYGLASS POLYGLASS<br />

ROOF ROOF USA USA USA USA<br />

SYSTEMS INC. SYSTEMS INC.<br />

2. PRODUCT NAME BITUTAK MB BITUTAK MB POLYFLEX POLYFLEX 5 POLYBOND POLYBOND G<br />

MINERAL<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier APP APP APP APP APP APP<br />

Thickness (mils) 152 160 160 200 160 180<br />

Top Surface SMOOTH MINERAL SMOOTH SMOOTH SMOOTH MINERAL<br />

Reinforcing Material POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

Colors BLACK BLACK, WHITE, BLACK BLACK BLACK VARIOUS<br />

Installed Weight (lbs./ft 2 without ballast) 0.89<br />

WEATHER<br />

WOOD 1.02 0.90 1.10 0.90 1.05<br />

KINDS OF FIELD SURFACING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD TORCH TORCH TORCH TORCH TORCH TORCH<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method) TORCH TORCH TORCH TORCH TORCH TORCH<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber O O O O O O<br />

Mineral Fiber O O O O O O<br />

Polystyrene O O O O O O<br />

Cellular Glass O O O O O O<br />

Phenolic O O O O O O<br />

Fiberboard O O O O O O<br />

Perlite O O O O O O<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O O O O<br />

Gypsum O O O O O O<br />

Concrete X X X O X O X O X O<br />

Wood Plank O O O O O O<br />

Plywood O O O O O O<br />

Existing Built-up Membrane O O X O X O X O X O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 14- 120 40 -120 40 – 120 40 – 120 40 – 120 40 – 120<br />

12. FLASHING MATERIAL SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

13. FLASHING METHOD TORCH TORCH TORCH TORCH TORCH TORCH<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA ITALY ITALY ITALY ITALY<br />

Manufacture USA USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1961 1961 1961 1961<br />

Within USA 1997 1997 1991 1991 1991 1991<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA 100 MILLION 100 MILLION 80 MILLION 10 MILLION<br />

Within USA 3 MILLION 1 MILLION 200,000 50,000<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS 1 1 2 2 2 2<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) NO NO YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: D QUNADT D QUNADT 800/222–9782 800/222–9782 800/222–9782 800/222–9782<br />

888/663-2488 888/663-2488<br />

22. TECHNICAL INFORMATION, CONTACT: K HUNT K HUNT 800/222–9782 800/222–9782 800/222–9782 800/222–9782<br />

888/663-2488 888/663-2488<br />

23. SEE APPENDIX IF CHECKED X X<br />

148


Modified Bitumen Part 1 - General Information<br />

POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS<br />

USA USA USA USA USA USA USA USA USA USA<br />

POLYFLEX G POLYFLEX G-FR DIAMOND DUFLEX DUFLEX 5 DUFLEX G INSULROOFING INSULROOFING INSULBASE ELASTOSHIELD<br />

BLACK GRANULAR TS4<br />

APP APP APP APP APP APP APP APP APP SBS<br />

180 180 160 160 200 180 160 160 80 180<br />

MINERAL MINERAL MINERAL SMOOTH SMOOTH MINERAL 1/2" INSULATION 1/2" INSULATION 1/2" INSULATION MINERAL<br />

POLYESTER POLYESTER POLYESTER POLYESTER,<br />

FIBERGLASS<br />

POLYESETER,<br />

FIBERGLASS<br />

POLYESTER,<br />

FIBERGLAS<br />

SMOOTH SMOOTH SMOOTH<br />

POLYESTER POLYESTER POLYESTER POLYESTER<br />

VARIOUS VARIOUS BLACK BLACK BLACK VARIOUS BLACK BLACK BLACK VARIOUS<br />

1.05 1.10 0.90 0.90 1.10 1.05 1.30 1.40 1.00 1.05<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH HOT/<br />

TORCH TORCH TORCH<br />

TORCH TORCH TORCH TORCH TORCH TORCH HOT/TORCH<br />

X X X X X X X X X X<br />

POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

O O O O O O X X X O<br />

O O O O O O X X X O<br />

O O O O O O X X X O<br />

O O O O O O X X X O<br />

O O O O O O X X X O<br />

O O O O O O X X X O<br />

O O O O O O X X X O<br />

O O O O O O X X X O<br />

O O O O O O X X X O<br />

O O O O O O X X X O<br />

X O X O X O X O X O X O X X X O<br />

O O O O O O X X X O<br />

O O O O O O X X X O<br />

X O X O X O X O X O X O X X X O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120<br />

POLYFLEX SAME POLYFLEX SAME SAME SAME POLYFLEX POLYFLEX POLYFLEX SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH HOT<br />

YES YES YES YES YES YES YES YES YES YES<br />

ITALY ITALY ITALY ITALY ITALY ITALY ITALY ITALY ITALY ITALY<br />

USA USA USA USA USA USA USA USA USA USA<br />

1961 1961 1961 1961 1961 1961 1961 1961 1961 1961<br />

1991 1991 1991 1991 1991 1991 1991 1991 1991 1991<br />

MILLIONS MILLIONS MILLIONS MILLIONS THOUSANDS THOUSANDS<br />

MILLIONS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

2 2 2 2 2 2 2 2 2 2<br />

YES YES YES YES YES YES YES YES YES YES<br />

800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782<br />

800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782<br />

149


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS<br />

USA USA USA USA USA USA<br />

2. PRODUCT NAME ELASTOFLEX ELASTOFLEX ELASTOFLEX ELASTOBASE ELASTOFLEX ELASTOFLEX<br />

S6 GS-6 G S6-FR V VG<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS SBS SBS SBS<br />

Thickness (mils) 120 140 140 80 120 140<br />

Top Surface SMOOTH MINERAL MINERAL SMOOTH SMOOTH MINERAL<br />

Reinforcing Material POLYESTER POLYESTER POLYESTER FIBERGLASS FIBERGLASS FIBERGLASS<br />

Colors BLACK VARIOUS VARIOUS BLACK BLACK VARIOUS<br />

Installed Weight (lbs./ft 2 without ballast) .80 .85 .85 .80 .80 .90<br />

KINDS OF FIELD SURFACING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD HOT HOT HOT HOT / COLD / HOT HOT<br />

MECHANICAL<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method) MECHANICAL<br />

Fully Adhered (method) HOT HOT HOT HOT/COLD HOT HOT<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X X X<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber O O O X O O<br />

Mineral Fiber O O O X O O<br />

Polystyrene O O O X O O<br />

Cellular Glass O O O X O O<br />

Phenolic O O O X O O<br />

Fiberboard O O O X O O<br />

Perlite O O O X O O<br />

Polyisocyanurate O O O X O O<br />

Polythane O O O X O O<br />

Gypsum O O O X O O<br />

Concrete O O O X O O<br />

Wood Plank O O O X O O<br />

Plywood O O O X O O<br />

Existing Built-up Membrane O O O X O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120<br />

12. FLASHING MATERIAL SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

13. FLASHING METHOD HOT HOT HOT HOT / COLD HOT HOT<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin ITALY ITALY ITALY ITALY ITALY ITALY<br />

Manufacture USA USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1961 1961 1961 1961 1961 1961<br />

Within USA 1991 1991 1991 1991 1991 1991<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

Within USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS 2 2 2 2 2 2<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782<br />

22. TECHNICAL INFORMATION, CONTACT: 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782 800/222–9782<br />

23. SEE APPENDIX IF CHECKED<br />

150


Modified Bitumen Part 1 - General Information<br />

POLYGLASS POLYGLASS POLYGLASS POLYGLASS SIPLAST, SIPLAST, SIPLAST, SIPLAST, SIPLAST, SIPLAST,<br />

USA USA USA USA INC. INC. INC. INC. INC. INC.<br />

ELASTOFLEX DUFLEX ELASTOFLEX POLYFLEX PARADIENE PARADIENE PARADIENE PARADIENE PARADIENE PARADIENE<br />

VG-FR G FR SA-P SA-P 20 20 HT 20 PR 20 EG 30 30 HT<br />

SBS APP SBS APP SBS SBS SBS SBS SBS SBS<br />

140 180 140 140 91 91 91 118 130 130<br />

MINERAL MINERAL MINERAL MINERAL PLAIN PLAIN PLAIN PLAIN MINERAL MINERAL<br />

FIBERGLASS<br />

POLYESTER<br />

FIBERGLASS<br />

POLYESTER POLYESTER GLASS MAT GLASS MAT,<br />

GLASS SCRIM<br />

POLYESTER/<br />

GLASS SCRIM<br />

GLASS MAT /<br />

GLASS SCRIM<br />

GLASS MAT GLASS MAT /<br />

GLASS SCDRIM<br />

VARIOUS VARIOUS VARIOUS VARIOUS BLACK BLACK BLACK BLACK VARIOUS VARIOUS<br />

.90 1.10 0.90 0.90 0.62 0.62 0.60 0.84 0.90 0.90<br />

NONE NONE NONE NONE PARADIENE 30 PARADIENE 30 PARADIENE 30 NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT TORCH SELF-ADHERED SELF-ADHRED HOT MOP / HOT MOP / HOT MOP / HOT MOP / HOT MOP / HOT MOP /<br />

PA-311 PA-311 PA-311 PA-311 PA-311 PA-311<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

MOP/PA-311 ADH MOP/PA-311 ADH MOP/PA-311 ADH MOP/PA-311 ADH<br />

HOT TORCH SELF-ADHERED SELF-ADHERED MOP/PA-311 ADH MOP/PA-311 ADH MOP/PA-311 ADH MOP/PA-311 ADH MOP/PA-311 ADH MOP/PA-311 ADH<br />

X X X X X X X X X<br />

POS DRAIN POS DRAIN POS DRAIN POS DRAIN DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL<br />

O O O O X X X X X X<br />

O O O O X X X X X X<br />

O O X O X O O O O O O O<br />

O O O O X O X O X O X O X O X O<br />

O O O O O O O O O O<br />

O O X O X O X X X X X X<br />

O O O O X X X X X X<br />

O O X O X O X X X X X X<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O X O X O X O O O O O O O<br />

O O X O X O O O O O O O<br />

O O X O X O O O O O O O<br />

O X O X O X O O O O O O O<br />

NONE NONE NONE NONE NONE NONE NONE<br />

40 – 120 40 - 120 50 - 100 50 - 100 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120<br />

SAME SAME SAME SAME VERAL VERAL<br />

MATERIAL MATERIAL MATERIAL MATERIAL<br />

HOT TORCH SELF-ADHERED SELF-ADHERED TORCH TORCH<br />

YES YES YES YES NO NO NO NO NO<br />

ITALY ITALY ITALY ITALY FRANCE FRANCE FRANCE USA FRANCE FRANCE<br />

USA USA USA USA USA USA USA USA USA USA<br />

1961 1961 1996 1996 1968 1968<br />

1991 1991 1997 1997 1979 1979<br />

THOUSANDS THOUSANDS THOUSANDS<br />

THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT<br />

2 2 2 2 9 9 9 9 9 9<br />

YES YES YES YES YES YES YES YES YES YES<br />

800/222–9782 800/222–9782 800/222–9782 800/222–9782 J. MOLLENHOFF J. MOLLENHOFF J. MOLLENHOFF J. MOLLENHOFF J. MOLLENHOFF J. MOLLENHOFF<br />

972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070<br />

800/222–9782 800/222–9782 800/222–9782 800/222–9782 K. WOLFORD K. WOLFORD K. WOLFORD K. WOLFORD K. WOLFORD K. WOLFORD<br />

972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070<br />

X X X X X X<br />

151


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME SIPLAST, SIPLAST, SIPLAST, SIPLAST, SIPLAST, SIPLAST,<br />

INC. INC. INC. INC. INC. INC.<br />

2. PRODUCT NAME PARADIENE PARAFOR VERAL VERAL VERAL PARADIENE<br />

40 FR 50 LT (ALUM FACED) (COPPER) (STAINLESS 20 HV<br />

STEEL)<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS SBS SBS SBS<br />

Thickness (mils) 150 180 138 138 138 119<br />

Top Surface MINERAL MINERAL ALUMINUM COPPER STAINLESS PLAIN<br />

STEEL<br />

Reinforcing Material GLASS MAT /<br />

GLASS SCRIM<br />

POLYESTER /<br />

GLASS SCRIM<br />

GLASS MAT /<br />

GLASS SCRIM<br />

GLASS MAT /<br />

GLASS SCRIM<br />

GLASS MAT /<br />

GLASS SCRIM<br />

GLASS MAT<br />

Colors VARIOUS VARIOUS ALUMINUM COPPER STAIN/STEEL BLACK<br />

Installed Weight (lbs./ft 2 without ballast) 1.15 1.41 0.92 1.09 1.05 0.90<br />

KINDS OF FIELD SURFACING REQUIRED NONE NONE NONE NONE NONE PARADIENE<br />

30<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD HOT MOP / HOT MOP / HOT MOP HOT MOP HOT MOP HOT MOP /<br />

PA-311 TORCH / PA-311 OR TORCH OR TORCH OR TORCH PA-311<br />

ADHESIVE ADHESIVE ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method) MOP/TOR/PA-311 AD MOP/PA-311 ADH<br />

Fully Adhered (method) MOP/PA-311 ADH MOP/TOR/PA-311 AD MOP OR TORCH MOP OR TORCH MOP OR TORCH MOP/PA-311 ADH<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

X<br />

8. MINIMUM SLOPE REQUIRED 1/4" 1/2" 1/2" 1/2 " 1/2 " DEAD LEVEL<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber X X X X X X<br />

Mineral Fiber X X X X X X<br />

Polystyrene O O O O O O<br />

Cellular Glass X O X O X O X O X O O<br />

Phenolic O O O O O O<br />

Fiberboard X X X X X X<br />

Perlite X X X X X X<br />

Polyisocyanurate X X X X X X<br />

Polythane O O O O O O<br />

Gypsum O O O O O O<br />

Concrete O O O O O O<br />

Wood Plank O O O O O O<br />

Plywood O O O O O O<br />

Existing Built-up Membrane O O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120<br />

12. FLASHING MATERIAL VERAL SAME SAME SAME SAME<br />

MATERIAL / MATERIAL MATERIAL MATERIAL<br />

13. FLASHING METHOD TORCH TORCH TORCH TORCH TORCH<br />

VERAL<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin FRANCE FRANCE FRANCE FRANCE FRANCE USA<br />

Manufacture USA USA USA USA FRANCE USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA<br />

Within USA<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 9 9 9 9 9 9<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: J. MOLLENHOFF J. MOLLENHOFF J. MOLLENHOFF J. MOLLENHOFF J. MOLLENHOFF J. MOLLENHOFF<br />

972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070<br />

22. TECHNICAL INFORMATION, CONTACT: K. WOLFORD K. WOLFORD K. WOLFORD K. WOLFORD K. WOLFORD K. WOLFORD<br />

972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070<br />

23. SEE APPENDIX IF CHECKED X X X X X X<br />

152


Modified Bitumen Part 1 - General Information<br />

SIPLAST, SIPLAST, SIPLAST, SIPLAST, SIPLAST, SIPLAST, SIPLAST, SOPREMA, SOPREMA, SOPREMA,<br />

INC. INC. INC. INC. INC. INC. INC. INC. INC. INC.<br />

PARADIENE PARADIENE PARADIENE PARADIENE PARADIENE PARADIENE PARADIENE SOPRALENE SOPRALENE SOPRALENE<br />

20 TG 20 HT TG 20 PR TG 20 EG TG 20 HV TG 30 TG 30 HT TG 180 FLAM 180 GR<br />

SBS SBS SBS SBS SBS SBS SBS SBS SBS SBS<br />

110 110 110 138 138 150 150 120 120 160<br />

PLAIN PLAIN PLAIN PLAIN PLAIN MINERAL MINERAL SAND PLASTIC CERAMIC<br />

FILM GRANULES<br />

GLASS MAT GLASS MAT /<br />

GLASS SCRIM<br />

POLYESTER /<br />

GLASS SCRIM<br />

GLASS MAT /<br />

GLASS SCRIM<br />

GLASS MAT GLASS MAT GLASS MAT /<br />

GLASS SCRIM<br />

NONWOVEN NONWOVEN NONWOVEN<br />

BLACK BLACK BLACK BLACK BLACK VARIOUS VARIOUS BLACK BLACK VARIOUS<br />

0.76 0.76 0.95 0.96 0.96 1.10 1.10 0.75 0.73 0.98<br />

PARADIENE PARADIENE PARADIENE PARADIENE PARADIENE NONE NONE SOPRALENE OR SOPRALENE OR NONE<br />

30TG 30TG 30TG 30TG 30TG ELASTOPHENE ELASTOPHENE<br />

CAP SHEET<br />

CAP SHEET<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH HOT MOP HEAT FUSED HOT MOP<br />

OR COLD<br />

OR COLD<br />

ADHESIVE<br />

ADHESIVE<br />

TORCH TORCH TORCH TORCH TORCH<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH MOP OR ADHES HEAT FUSED MOP OR ADHES<br />

X X X X X X X X X X<br />

DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL 1/8:12 DEAD LEVEL 1/8:12<br />

O O O O O O O X O X O O<br />

O O O O O O O X O X O O<br />

O O O O O O O O O O<br />

O O O O O O O X O X O O<br />

O O O O O O O O<br />

O O O O O O O X O X O O<br />

O O O O O O O X O X O O<br />

X X X X X X X O O O<br />

O O O O O O O O O O<br />

O O O O O O O X O X O O<br />

X O X O X O X O X O X O X O X O X O O<br />

X O X O X O X O X O X O X O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

NONE NONE NONE NONE NONE NONE<br />

40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 40 – 120 35 – 120 35 – 120 35 – 120<br />

VERAL VERAL SAME SAME SAME<br />

MATERIAL OR MATERIAL OR MATERIAL OR<br />

FOIL MEMBRANE FOIL MEMBRANE FOIL MEMBRANE<br />

TORCH TORCH HEAT FUSED, HEAT HEAT FUSED,<br />

HOT MOP OR FUSED HOT MOP OR<br />

COLD ADHESIVE<br />

COLD ADHESIVE<br />

NO NO NO NO NO NO NO YES YES YES<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA, FR, CAN USA, FR, CAN USA, FR, CAN<br />

1975 1975 1975<br />

1984 1984 1984<br />

MILLIONS MILLIONS MILLIONS<br />

DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

9 9 9 9 9 9 9 5 5 5<br />

YES YES YES YES YES YES YES YES YES YES<br />

J. MOLLENHOFF J. MOLLENHOFF J. MOLLENHOFF J. MOLLENHOFF J. MOLLENHOFF J. MOLLENHOFF J. MOLLENHOFF SALES MGR SALES MGR SALES MGR<br />

972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070 800/356-3521 800/356-3521 800/356-3521<br />

K. WOLFORD K. WOLFORD K. WOLFORD K. WOLFORD K. WOLFORD K. WOLFORD K. WOLFORD TECH MGR TECH MGR TECH MGR<br />

972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070 972/869–0070 330/334-0055 330/334-0055 330/334-0055<br />

X X X X X X X<br />

153


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA,<br />

INC. INC. INC. INC. INC. INC.<br />

2. PRODUCT NAME SOPRALENE SOPRALENE SOPRALENE SOPRALENE SOPRALENE SOPRALENE<br />

FLAM 250 FLAM 250 GR FLAM 250 GR 350<br />

180 GR 250<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS SBS SBS SBS<br />

Thickness (mils) 160 160 160 160 160 160<br />

Top Surface CERAMIC SAND PLASTIC CERAMIC CERAMIC SAND<br />

GRANULES FILM GRANULES GRANULES<br />

Reinforcing Material NONWOVEN NONWOVEN NONWOVEN NONWOVEN NONWOVEN NONWOVEN<br />

Colors VARIOUS BLACK BLACK VARIOUS VARIOUS BLACK<br />

Installed Weight (lbs./ft 2 without ballast) 0.99 1.01 0.99 0.98 1.13 0.97<br />

KINDS OF FIELD SURFACING REQUIRED NONE SOPRALENE OR SOPRALENE OR NONE NONE SOPRALENE OR<br />

ELASTOPHENE ELASTOPHENE ELASTOPHENE<br />

CAP SHEET CAP SHEET CAP SHEET<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD HEAT FUSED HOT MOP HEAT FUSED HOT MOP HEAT FUSED HOT MOP<br />

OR COLD OR COLD OR COLD<br />

ADHESIVE ADHESIVE ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method) HEAT FUSED MOP OR ADHES HEAT FUSED MOP OR ADHESIVE HEAT FUSED MOP OR ADHESIVE<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X X X<br />

8. MINIMUM SLOPE REQUIRED DEAD LEVEL 1/8:12 DEAD LEVEL 1/8:12 DEAD LEVEL 1/8:12<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber O X O O X O O X O<br />

Mineral Fiber O X O X X O X O X O<br />

Polystyrene O O X X O X O O<br />

Cellular Glass O X O X X O X O X O<br />

Phenolic O O O O<br />

Fiberboard O X O X O O X O<br />

Perlite O X O X X O X O X O<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O O O O<br />

Gypsum X O X O X X O X O X O<br />

Concrete O X O X X O X O X O<br />

Wood Plank O O O O O O<br />

Plywood O O O O O O<br />

Existing Built-up Membrane O O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 35 – 120 35 – 120 0 - 120 35 – 120 0 - 120 35 – 120<br />

12. FLASHING MATERIAL SAME SAME SAME SAME SAME SAME<br />

MATERIAL OR MATERIAL OR MATERIAL OR MATERIAL OR MATERIAL OR MATERIAL OR<br />

FOIL MEMBRANE FOIL MEMBRANE FOIL MEMBRANE FOIL MEMBRANE FOIL MEMBRANE FOIL MEMBRANE<br />

13. FLASHING METHOD HEAT HEAT FUSED, HEAT HEAT FUSED, HEAT FUSED HEAT FUSED,<br />

FUSED HOT MOP OR FUSED HOT MOP OR HOT MOP OR<br />

COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1975 1975 1975 1975 1975 1975<br />

Within USA 1984 1984 1984 1984 1984 1984<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 5 5 5 5 5 5<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR<br />

800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521<br />

22. TECHNICAL INFORMATION, CONTACT: TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR<br />

330/334-0055 330/334-0055 330/334-0055 330/334-0055 330/334-0055 330/334-0055<br />

23. SEE APPENDIX IF CHECKED<br />

154


Modified Bitumen Part 1 - General Information<br />

SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA,<br />

INC. INC. INC. INC. INC. INC. INC. INC. INC. INC.<br />

SOPRALENE ELASTOPHENE ELASTOPHENE ELASTOPHENE SOPRALENE SOPRALENE SOPRALENE 250 ELASTOPHENE ELASTOPHENE ELASTOPHENE<br />

350 GR FLAM GR 280 FR GR FLAM 180 FR GR FLAM 250 FLAM GR PS<br />

FR GR FR GR<br />

SBS SBS SBS SBS SBS SBS SBS SBS SBS SBS<br />

200 90 120 136 160 160 160 160 145 90<br />

CERAMIC SAND PLASTIC CERAMIC CERAMIC CERAMIC CERAMIC CERAMIC CERAMIC PLASTIC<br />

GRANULES FILM GRANULES GRANULES GRANULES GRANULES GRANULES GRANULES FILM<br />

NONWOVEN FIBERGLASS FIBERGLASS FIBERGLASS NONWOVEN NONWOVEN NONWOVEN NONWOVEN FIBERGLASS FIBERGLASS<br />

VARIOUS BLACK BLACK VARIOUS VARIOUS VARIOUS VARIOUS VARIOUS VARIOUS BLACK<br />

1.32 0.57 0.79 0.90 0.98 0.99 0.98 0.98 0.60 0.60<br />

NONE ELASTOPHENE, ELASTOPHENE, NONE NONE NONE NONE NONE NONE ELASTOPHENE,<br />

SOPRALENE SOPRALENE SOPRALENE<br />

GRANULE GRANULE GRANULE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT MOP HOT MOP HEAT FUSED HOT MOP HOT MOP HEAT FUSED MOP OR HEAT FUSED HEAT FUSED HOT MOP<br />

OR COLD OR COLD OR COLD OR COLD COLD OR COLD<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

HOP OR ADHESIVE MOP OR ADHESIVE HEAT FUSED MOP OR ADHESIVE MOPOR ADHESIVE HEAT FUSED MOP OR ADHES HEAT FUSED HEAT FUSED MOP OR ADHESIVE<br />

X X X X X X X<br />

1/8:12 1/8:12 DEAD LEVEL 1/8:12 1/8:12 DEAD LEVEL 1/8:12 DEAD LEVEL DEAD LEVEL 1/8:12<br />

X O X O O O O O X O X O O O<br />

X O X O X O O O O X O X O O X O<br />

X O O O O O O X O X O O O<br />

X O X O X O O O O X O X O O X O<br />

O O O O<br />

O X O O O O O X O X O O O<br />

X O X O X O O O O X O X O O X O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X O X O X O O O X O X O X O O X O<br />

X O X O X O O O O X O X O O X O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O X O X O O O O X O X O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

35 - 120 35 – 120 35 – 120 0 - 120 35 – 120 35 – 120 35 – 120 0 – 120 0 – 120 0 – 120<br />

SAME SAME SOPRALENE SOPRALENE SAME SAME SAME SAME SOPRALENE SOPRALENE<br />

MATERIAL OR MATERIAL OR OR FOIL OR FOIL MATERIAL OR MATERIAL OR MATERIAL OR MATERIAL OR OR FOIL OR FOIL<br />

FOIL MEMBRANE FOIL MEMBRANE MEMBRANE MEMBRANE FOIL MEMBRANE FOIL MEMBRANE FOIL MEMBRANE FOIL MEMBRANE MEMBRANE MEMBRANE<br />

HEAT FUSED, HEAT FUSED, HEAT FUSED, HEAT FUSED, HEAT FUSED, HEAT FUSED HEAT FUSED, HEAT FUSED HEAT FUSED, HEAT FUSED,<br />

HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR<br />

COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN<br />

1975 1975 1975 1975 1975 1975 1975 1975 1975 1975<br />

1984 1984 1984 1984 1984 1984 1984 1984 1984 1984<br />

MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS<br />

DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

5 5 5 5 5 5 5 5 5 5<br />

YES YES YES YES YES YES YES YES YES YES<br />

SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR<br />

800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521<br />

TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR<br />

330/334-0055 330/334-0055 330/334-0055 330/334-0055 330/334-0055 330/334-0055 330/334-0055 330/334-0055 330/334-0055 330/334-0055<br />

155


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA,<br />

INC. INC. INC. INC. INC. INC.<br />

2. PRODUCT NAME ELASTOPHENE ELASTOPHENE ELASTOPHENE ELASTOPHENE SOPRALAST SOPRALAST<br />

180 180 PS FLAM FR GR 50 TV ALU TV COPPER<br />

FR GR<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS SBS SBS SBS<br />

Thickness (mils) 90 90 145 136 160 140<br />

Top Surface SAND SAND CERAMIC CERAMIC ALUMINUM COPPER<br />

GRANULES GRANULES<br />

Reinforcing Material NONWOVEN NONWOVEN FIBERGLASS FIBERGLASS GLASS GRID GLASS GRID<br />

Colors BLACK BLACK VARIOUS VARIOUS ALUMINUM COPPER<br />

Installed Weight (lbs./ft 2 without ballast) 0.55 0.53 0.96 0.90 0.92 0.93<br />

KINDS OF FIELD SURFACING REQUIRED ELASTOPHENE, ELASTOPHENE, NONE NONE NONE NONE<br />

SOPRALENE SOPRALENE<br />

GRANULE<br />

GRANULE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD MOP OR MOP OR HEAT FUSED HOT MOP HEAT FUSED HEAT FUSED<br />

COLD COLD OR COLD<br />

ADHESIVE ADHESIVE ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method) MOP OR ADHESIVE MOP OR TORCH HEAT FUSED MOP OR ADHESIVE HEAT FUSED HEAT FUSED<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED 1/8:12 1/8:12 1/8:12 1/8:12 1/2" 1/2"<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber X O O O O O O<br />

Mineral Fiber X O X O O O O O<br />

Polystyrene O O O O O O<br />

Cellular Glass X O X O O O O O<br />

Phenolic<br />

Fiberboard O X O O O O O<br />

Perlite X O X O O O O O<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O O O O<br />

Gypsum X O X O O O O O<br />

Concrete X O X O O O O O<br />

Wood Plank O O O O O O<br />

Plywood O O O O O O<br />

Existing Built-up Membrane O O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 0 – 120 0 – 120 0 – 120 0 - 120 35 – 120 0 – 120<br />

12. FLASHING MATERIAL SAME SAME SOPRALENE SOPRALENE SAME SAME<br />

MATERIAL OR MATERIAL OR OR FOIL OR FOIL MATERIAL OR MATERIAL<br />

FOIL MEMBRANE FOIL MEMBRANE MEMBRANE MEMBRANE FOIL MEMBRANE<br />

13. FLASHING METHOD HEAT FUSED, HEAT FUSED, HEAT FUSED HEAT FUSED HEAT FUSED HEAT FUSED<br />

HOT MOP OR HOT MOP OR OR COLD OR COLD<br />

COLD ADHESIVE COLD ADHESIVE ADHESIVE ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1975 1975 1975 1975 1975 1975<br />

Within USA 1984 1984 1984 1984 1984 1984<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS, DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 5 5 5 5 5 5<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR<br />

800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521<br />

22. TECHNICAL INFORMATION, CONTACT: TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR<br />

330/334-0055 330/334-0055 330/334-0055 330/334-0055 330/334-0055 330/334-0055<br />

23. SEE APPENDIX IF CHECKED<br />

156


Modified Bitumen Part 1 - General Information<br />

SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA, SOPREMA,<br />

INC. INC. INC. INC. INC. INC. INC. INC. INC. INC.<br />

SOPRALAST SOPRAFIX (F) SOPRALENE SOPRALENE 180 ELASTOPHENE LASTOBOND COLPHENE GR COLDPHENE COLDPHENE COLDPHENE<br />

50 TV INOX (H) (S) (T) 350 PS SP 3.5mm 3.0mm FR GR HR GR HR-FR GR<br />

SBS SBS SBS SBS SBS SBS SBS SBS SBS SBS<br />

160 120 120 140 120 108 140 140 140 140<br />

STAINLESS PLASTIC PLASTIC SAND/PLASTIC SAND SAND CERAMIC CERAMIC CERAMIC CERAMIC<br />

FILM FILM FILM GRANULES GRANULES GRANULES GRANULES<br />

GLASS GRID NONWOVEN NONWOVEN NONWOVEN FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS GLASS GRID GLASS GRID<br />

STAINLESS BLACK BLACK BLACK BLACK BLACK VARIOUS VARIOUS VARIOUS VARIOUS<br />

1.15 0.73 1.06 0.80 0.79 0.60 0.90 0.90 0.90 0.90<br />

NONE SOPRALENE OR SOPRALENE OR SOPRALENE OR SHINGLES NONE NONE NONE NONE<br />

ELASTOPHENE ELASTOPHENE ELASTOPHENE OR TILE<br />

CAP SHEET CAP SHEET CAP SHEET<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HEAT FUSED HEAT FUSED HOT MOP HEAT FUSED HOT MOP SELF ADHESIVE SELF ADHESIVE SELF ADHESIVE SELF ADHESIVE SELF ADHESIVE<br />

OR COLD<br />

OR COLD<br />

ADHESIVE<br />

ADHESIVE<br />

HEAT FUSED MECH. ATTACHED MOP OR ADHESIVE HEAT FUSED HOT MOP SELF ADHESIVE SELF ADHESIVE SELF ADHESIVE SELF ADHESIVE SELF ADHESIVE<br />

X<br />

1/2" 1/8:12 1/8:12 DEAD LEVEL 1/8:12 1/8:12 1/8:12 1/8:12 1/8:12 1/8:12<br />

O X O X O O O O O O O O<br />

O X O X O X O X O O O O O O<br />

O O O O O X O X X X<br />

O X O X O X O X O O O O O O<br />

O O O O O<br />

O X O X O O O O O O O O<br />

O X O X O X O X O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O X O X O X O X O X X X X X<br />

O X O X O X O X O O O O O O<br />

O X O O O O O O O O O<br />

O X O O O O O O O O O<br />

O X O O O O O O O O O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

0 – 120 0 – 120 0 – 120 0 – 120 35 - 120 40 - 120 40 - 120 40 - 120 40 - 120 40 - 120<br />

SAME SOPRALENE SOPRALENE SOPRALENE SOPRALENE SOPRALENE SOPRALENE SOPRALENE SOPRALENE SOPRALENE<br />

MATERIAL OR FOIL OR FOIL OR FOIL OR FOIL OR FOIL OR FOIL OR FOIL OR FOIL OR FOIL<br />

MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE<br />

HEAT FUSED HEAT FUSED HEAT FUSED HEAT FUSED HEAT FUSED, HEAT FUSED, HEAT FUSED, HEAT FUSED, HEAT FUSED, HEAT FUSED,<br />

OR COLD OR COLD OR COLD HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP OR<br />

ADHESIVE ADHESIVE ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN USA, FR, CAN<br />

1975 1975 1975 1975 1975 1975 1975 1975 1975 1975<br />

1984 1984 1984 1984 1984 1984 1984 1984 1984 1984<br />

MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS<br />

DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

5 5 5 5 5 5 5 5 5 5<br />

YES YES YES YES YES YES YES YES YES YES<br />

SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR SALES MGR<br />

800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521 800/356-3521<br />

TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR TECH MGR<br />

330/334-0066 330/334-0066 330/334-0066 330/334-0066 330/334-0066 330/334-0066 330/334-0066 330/334-0066 330/334-0066 330/334-0066<br />

157


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME SOPREMA, SOUTHWESTERN SOUTHWESTERN TAMKO TAMKO TAMKO<br />

INC. PETROLEUM PETROLEUM ROOFING ROOFING ROOFING<br />

CORP. CORP. PRODUCTS PRODUCTS PRODUCTS<br />

2. PRODUCT NAME SOPRAFIX (X) SWEPCO SWEPCO AWAPLAN AWAPLAN AWAPLAN<br />

UNI+SHIELD UNI+SHIELD II PREMIUM 170 PREMIUM<br />

TRI-POLYMER<br />

FR<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS APP SBS SBS SBS SBS<br />

Thickness (mils) 160 160 53 155 145 155<br />

Top Surface PLASTIC MODIFIED MODIFIED GRANULE GRANULE GRANULE<br />

FILM ASPHALT ASPHALT<br />

Reinforcing Material NONWOVEN POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

Colors BLACK BLACK BLACK VARIOUS VARIOUS VARIOUS<br />

Installed Weight (lbs./ft 2 without ballast) 0.97 0.90 0.33 1.04 0.99 1.04<br />

KINDS OF FIELD SURFACING REQUIRED SOPRALENE OR SWEPCO SWEPCO NONE NONE NONE<br />

ELASTOPHENE COATING COATING<br />

CAP SHEET<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD HEAT FUSED TORCH COLD ADHESIVE HOT MOP HOT MOP HOT MOP<br />

OR COLD OR COLD<br />

ADHESIVE<br />

ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

TORCH<br />

Fully Adhered (method) MECH. ATTACHED TORCH COLD ADHESIVE HOT MOP/COLD HOT MOP/COLD HOT MOP<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED 1/8:12 1/4" 1/4" POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber X O O X X X X<br />

Mineral Fiber X O O X X X X<br />

Polystyrene O O O O<br />

Cellular Glass X O X O X X X X<br />

Phenolic O O<br />

Fiberboard X O O X X X X<br />

Perlite X O X O X X X X<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O<br />

Gypsum X O O O X X X<br />

Concrete X O X O O O O O<br />

Wood Plank X O O O X X X<br />

Plywood X O O O X X X<br />

Existing Built-up Membrane X O X O O X X X<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 40 - 120 5 - 125 40 -1 25<br />

12. FLASHING MATERIAL SOPRALENE SAME SAME SAME SAME SAME<br />

OR FOIL MATERIAL MATERIAL MATERIAL OR MATERIAL OR MATERIAL<br />

MEMBRANE VERSA-FLASH VERSA-FLASH<br />

13. FLASHING METHOD HEAT FUSED TORCH COLD ADHESIVE HOT MOP HOT MOP HOT MOP<br />

OR COLD OR COLD OR COLD<br />

ADHESIVE ADHESIVE ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin USA USA USA W GERMANY W GERMANY W GERMANY<br />

Manufacture USA, FR, CAN USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1975 1963 1990 1970<br />

Within USA 1984 1981 1993 1978 1986 1988<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA 30,000+ 50,000+<br />

Within USA MILLIONS 1,000,000+ 100,000+<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS,DIRECT DIRECT DIRECT DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS 5 27 27 27<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES NO NO YES YES YES<br />

21. SALES INFORMATION, CONTACT: SALES MGR R. KLEINTOP R. KLEINTOP DIST OFFICE DIST OFFICE DIST OFFICE<br />

800/356-3521 800/877-9372 800/877-9372<br />

22. TECHNICAL INFORMATION, CONTACT: TECH MGR R. KLEINTOP R. KLEINTOP TECH SERVICE TECH SERVICE TECH SERVICE<br />

330/334-0066 800/877-9372 800/877-9372 800/641–4691 800/641–4691 800/641–4691<br />

23. SEE APPENDIX IF CHECKED X X X<br />

158


Modified Bitumen Part 1 - General Information<br />

TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO TEXAS<br />

ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING REFINERY<br />

PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS CORP.<br />

AWAPLAN AWAPLAN AWAPLAN AWAPLAN AWAPLAN AWAPLAN AWAPLAN VERSA-FLEX VERSA-BASE MIGHTYPLATE<br />

170 FR PREMIUM 170 PREMIUM 170 FR VERSA- HEAT WELDING<br />

FR<br />

SMOOTH<br />

SBS SBS SBS SBS SBS SBS SBS SBS SBS APP<br />

145 155 145 155 145 150 180 115 90 157<br />

GRANULE GRANULE GRANULE GRANULE GRANULE SMOOTH GRANULE SMOOTH SMOOTH MODIFIED<br />

BITUMEN<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER FIBERGLASS NONWOVEN<br />

VARIOUS VARIOUS VARIOUS VARIOUS VARIOUS BLACK VARIOUS BLACK BLACK BLACK<br />

0.99 1.04 0.99 1.04 0.99 1.0 1.04 0.76 0.90 0.88<br />

NONE NONE NONE NONE NONE AWAPLAN, NONE AWAPLAN, AWAPLAN NONE<br />

COATING,<br />

GRAVEL<br />

GRAVEL<br />

X X X X X X X X X X<br />

X X X X X X X X X<br />

HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP TORCH HOT MOP HOT MOP TORCH<br />

OR COLD OR COLD OR TORCH OR COLD<br />

ADHESIVE ADHESIVE ADHESIVE<br />

HOT MOP HOT MOP/COLD HOT MOP/COLD HOT MOP HOT MOP MOP/TORCH/ADHS TORCH HOT MOP/COLD HOT MOP TORCH<br />

POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

X X X X X X X X X O<br />

X X X X X X X X X O<br />

O O O O O O O O O O<br />

X X X X X X X X X O<br />

O<br />

X X X X X X X X X O<br />

X X X X X X X X X O<br />

O O O O O O O O O O<br />

O<br />

X X X X X X X X X O<br />

O O O O O O O O O X O<br />

X X X X X X X X X O<br />

X X X X X X X X X O<br />

X X X X X X X X X X O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

0 – 120<br />

SAME SAME SAME SAME SAME SAME SAME AWAFLEX 170, AWAPLAN SAME<br />

MATERIAL MATERIAL OR MATERIAL OR MATERIAL MATERIAL MATERIAL MATERIAL AWAPREMIUM MATERIAL<br />

VERSA-FLASH<br />

VERSA-FLASH<br />

HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP TORCH<br />

OR COLD OR COLD OR COLD OR COLD OR COLD OR OR OR COLD<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE TORCH TORCH ADHESIVE<br />

NO NO NO NO NO NO NO NO NO NO<br />

W GERMANY W GERMANY W GERMANY W GERMANY W GERMANY W GERMANY W GERMANY USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1970<br />

1991 1978 1986 1988 1991 1986 1981 1997 1981<br />

MILLIONS<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DIRECT<br />

27 27 27 27 27 27 27 27 27<br />

YES YES YES YES YES YES YES YES YES YES<br />

DIST OFFICE DIST OFFICE DIST OFFICE DIST OFFICE DIST OFFICE DIST OFFICE DIST OFFICE DIST OFFICE DIST OFFICE J. MC GEE<br />

TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE J. MC GEE<br />

800/641–4691 800/641–4691 800/641–4691 800/641–4691 800/641–4691 800/641–4691 800/641–4691 800/641–4691 800/641-4691<br />

X X X X X X X X X<br />

159


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA,<br />

SA SA SA SA SA SA<br />

2. PRODUCT NAME MOPLY MOPLY MOPLY MOPLY MOPLY MOPLY<br />

FV 2 mm FV 3 mm FV 3 kg FV 4 kg FP 3 kg FP 4 kg<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier APP APP APP APP APP APP<br />

Thickness (mils) 80 120 104 136 104 136<br />

Top Surface SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH<br />

Reinforcing Material FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS POLYESTER POLYESTER<br />

Colors BLACK BLACK BLACK BLACK BLACK BLACK<br />

Installed Weight (lbs./ft 2 without ballast) 0.52 0.77 0.62 0.82 0.62 0.82<br />

KINDS OF FIELD SURFACING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD TORCH TORCH TORCH TORCH TORCH TORCH<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method) TORCH TORCH TORCH TORCH TORCH TORCH<br />

Fully Adhered (method) TORCH TORCH TORCH TORCH TORCH TORCH<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber<br />

Mineral Fiber X X X X X X<br />

Polystyrene X X X X X X<br />

Cellular Glass<br />

Phenolic X X X X X X<br />

Fiberboard X X X X X X<br />

Perlite X X X X X X<br />

Polyisocyanurate X X X X X X<br />

Polythane X X X X X X<br />

Gypsum X X X X X X<br />

Concrete X X X X X X<br />

Wood Plank<br />

Plywood<br />

Existing Built-up Membrane X X X X X X<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 30 - 120 30 - 120 30 - 120 30 - 120 30 - 120 30 - 120<br />

12. FLASHING MATERIAL SAME MATERIAL SAME MATERIAL SAME MATERIAL SAME MATERIAL SAME MATERIAL SAME MATERIAL<br />

13. FLASHING METHOD TORCH TORCH TORCH TORCH TORCH TORCH<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN<br />

Manufacture SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1996 1996 1996 1996 1996 1996<br />

Within USA<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

Within USA<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no)<br />

21. SALES INFORMATION, CONTACT: CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE<br />

22. TECHNICAL INFORMATION, CONTACT: TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE<br />

23. SEE APPENDIX IF CHECKED<br />

160


Modified Bitumen Part 1 - General Information<br />

TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA,<br />

SA SA SA SA SA SA SA SA SA SA<br />

MOPLY FP 3 mm MOPLY MOPLY MOPLY MOPLY MOPLY MOPLY MOPLY MOPLY FP 4 kg TEXAL<br />

FP 3 mm FP 4 mm FP 4 kg FP 5 kg FP 3 mm FP 4 Mm FP 4 KG FP 5 kg GARDEN FV 3 KG<br />

GARDEN MINERAL MINERAL MINERAL MINERAL MINERAL<br />

APP APP APP APP APP APP APP APP APP APP<br />

120 160 136 164 120 160 136 164 136 104<br />

SMOOTH SMOOTH SMOOTH SMOOTH GRANULE GRANULE GRANULE GRANULE GRANULE SMOOTH<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER FIBERGLASS<br />

BLACK BLACK BLACK BLACK GRA/GREEN/RE<br />

D/WHITE/NATUR<br />

AL<br />

GRA/GREEN/RE<br />

D/WHITE/NATUR<br />

AL<br />

GRA/GREEN/RE<br />

D/WHITE/NATUR<br />

AL<br />

GRA/GREEN/RE<br />

D/WHITE/NATUR<br />

AL<br />

0.77 0.98 0.82 1.02 0.77 0.98 0.82 1.02 0.82 0.62<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

GREEN<br />

BLACK<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH<br />

POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

30 - 120 30 - 120 30 - 120 30 - 120 30 - 120 30 - 120 30 - 120 30 - 120 30 - 120 25 - 120<br />

SAME MATERIAL SAME MATERIAL SAME MATERIAL SAME MATERIAL SAME MATERIAL SAME MATERIAL SAME MATERIAL SAME MATERIAL SAME MATERIAL SAME MATERIAL<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH<br />

NO NO NO NO NO NO NO NO NO NO<br />

SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN<br />

SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN<br />

1996 1996 1996 1996 1996 1996 1996 1996 1996 1985<br />

THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT<br />

CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE<br />

TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE<br />

161


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA,<br />

SA SA SA SA SA SA<br />

2. PRODUCT NAME TEXAS TEXAL TEXAL TEXAL TEXAL TEXAL<br />

FV 4 KG FP-S 3 KG FP-S-4 m FP-S 3 mm FP-S 4mm FP-S 4 kg<br />

MINERAL<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier APP APP APP APP APP APP<br />

Thickness (mils) 136 104 136 120 160 136<br />

Top Surface SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH GRANULE<br />

Reinforcing Material FIBERGLASS POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

Colors<br />

Installed Weight (lbs./ft 2 without ballast)<br />

BLACK<br />

0.82<br />

BLACK<br />

0.62<br />

BLACK<br />

0.82<br />

BLACK<br />

0.77<br />

BLACK<br />

0.98<br />

GRA/GREEN/RE<br />

D/WHITE/NATUR<br />

0.82 AL<br />

KINDS OF FIELD SURFACING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD TORCH TORCH TORCH TORCH TORCH TORCH<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method) TORCH TORCH TORCH TORCH TORCH TORCH<br />

Fully Adhered (method) TORCH TORCH TORCH TORCH TORCH TORCH<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber<br />

Mineral Fiber X X X X X X<br />

Polystyrene X X X X X X<br />

Cellular Glass<br />

Phenolic X X X X X X<br />

Fiberboard X X X X X X<br />

Perlite X X X X X X<br />

Polyisocyanurate X X X X X X<br />

Polythane X X X X X X<br />

Gypsum X X X X X X<br />

Concrete X X X X X X<br />

Wood Plank<br />

Plywood<br />

Existing Built-up Membrane X X X X X X<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 25 - 120 25 - 120 25 - 120 25 - 120 25 - 120 25 - 120<br />

12. FLASHING MATERIAL SAME MATERIAL SAME MATERIAL SAME MATERIAL SAME MATERIAL SAME SAME<br />

MATERIAL<br />

MATERIAL<br />

13. FLASHING METHOD TORCH TORCH TORCH TORCH TORCH TORCH<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN<br />

Manufacture SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1985 1985 1985 1985 1985 1985<br />

Within USA<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

Within USA<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no)<br />

21. SALES INFORMATION, CONTACT: CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE<br />

22. TECHNICAL INFORMATION, CONTACT: TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE<br />

23. SEE APPENDIX IF CHECKED<br />

162


Modified Bitumen Part 1 - General Information<br />

TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA,<br />

SA SA SA SA SA SA SA SA SA SA<br />

MOTERPLAS MOTERPLAS MOTERPLAS MODFLEX MODFLEX MODFLEX MODFLEX MODFLEX MODFLEX MODFLEX<br />

POLIMERICA POLIMERICA POLIMERICA FV 2.5 kg FV 3 mm FV 3 kg FV 4 kg FP 3 mm FP 4 mm FP 3 kg<br />

PE 3 kg PE 4 kg PE 4 mm<br />

APP APP APP SBS SBS SBS SBS SBS SBS SBS<br />

104 136 160 80 120 104 136 120 160 104<br />

SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH<br />

POLYETHYLENE POLYETHYLENE POLYETHYLENE FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS POLYESTER POLYESTER POLYESTER<br />

BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK<br />

0.62 0.82 0.98 0.52 0.77 0.62 0.82 0.77 0.98 0.62<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH<br />

POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

15 - 120 15 - 120 15 - 120 15 - 120 15 - 120 15 - 120 15 - 120 15 - 120 15 - 120 15 - 120<br />

SAME SAME SAME SAME SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH TORCH<br />

NO NO NO NO NO NO NO NO NO NO<br />

SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN<br />

SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN<br />

1985 1985 1985 1991 1991 1991 1991 1991 1991 1991<br />

THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT<br />

CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE<br />

TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE<br />

163


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA,<br />

SA SA SA SA SA SA<br />

2. PRODUCT NAME MODFLEX MODFLEX MODFLEX MOFLEX MODFLEX MODFLEX<br />

FP R kg FM 3 mm FP 4 kg FP 5 kg FP-S 5 kg FP 4 mm<br />

GARDEN GARDEN MINERAL<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS SBS SBS SBS<br />

Thickness (mils) 136 120 136 164 164 160<br />

Top Surface SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH GRANULE<br />

Reinforcing Material POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

Colors BLACK BLACK BLACK BLACK BLACK NATURAL<br />

Installed Weight (lbs./ft 2 without ballast) 0.82 0.77 0.82 1.02 1.02 0.98<br />

4. KINDS OF FIELD SURFACING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD TORCH TORCH TORCH TORCH TORCH TORCH<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method) TORCH TORCH TORCH TORCH TORCH TORCH<br />

Fully Adhered (method) TORCH TORCH TORCH TORCH TORCH TORCH<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber<br />

Mineral Fiber X X X X X X<br />

Polystyrene X X X X X X<br />

Cellular Glass<br />

Phenolic X X X X X X<br />

Fiberboard X X X X X X<br />

Perlite X X X X X X<br />

Polyisocyanurate X X X X X X<br />

Polythane X X X X X X<br />

Gypsum X X X X X X<br />

Concrete X X X X X X<br />

Wood Plank<br />

Plywood<br />

Existing Built-up Membrane X X X X X X<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 15 - 120 15 - 120 15 - 120 15 - 120 15 - 120 15 - 120<br />

12. FLASHING MATERIAL SAME SAME SAME SAME SAME SAME<br />

MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

13. FLASHING METHOD TORCH TORCH TORCH TORCH TORCH TORCH<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO<br />

15. COUNTRY OF:<br />

Origin SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN<br />

Manufacture SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1991 1991 1991 1991 1991 1991<br />

Within USA<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

Within USA<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no)<br />

21. SALES INFORMATION, CONTACT: CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE<br />

22. TECHNICAL INFORMATION, CONTACT: TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE<br />

23. SEE APPENDIX IF CHECKED<br />

164


Modified Bitumen Part 1 - General Information<br />

TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA,<br />

SA SA SA SA SA SA SA SA SA SA<br />

MODFLEX MODFLEX MORTERPLAS TEXSELF 1.5 TEXSELF M 1.5 TEXSELF HD TEXSELF PE TEXSELF FV TEXSELF FV 2C TEXSELF FV<br />

FP 4 kg FP-S 5 kg PARKING 2 mm 3 mm 4 kg<br />

MINERAL MINERAL MINERAL<br />

SBS SBS SBS SBS SBS SBS SBS SBS SBS SBS<br />

136 164 160 60 60 60 80 120 80 150<br />

GRANULE GRANULE POLYESTER POLYETHYLENE POLYETHYLENE POLYPROPYLENE SMOOTH SMOOTH SMOOTH GRANULE<br />

CROSS LAMINATED<br />

WOVEN<br />

POLYESTER POLYESTER POLYESTER POLYETHYLENE FIBERGLASS FIBERGLASS FIBERGLASS<br />

GRA/GREEN/RE<br />

D/WHITE/NATUR<br />

AL<br />

GRA/GREEN/RE<br />

D/WHITE/NATUR<br />

AL<br />

WHITE BLACK BLACK BLACK BLACK BLACK BLACK GRAY/GREEN/<br />

RED<br />

0.82 1.02 0.98 0.31 0.31 0.31 0.41 0.62 0.41 0.82<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

TORCH TORCH TORCH SELF-ADHESIVE SELF-ADHESIVE SELF-ADHESIVE SELF-ADHESIVE SELF-ADHESIVE SELF-ADHESIVE SELF-ADHESIVE<br />

TORCH TORCH TORCH<br />

TORCH TORCH TORCH SELF-ADHERING SELF-ADHERING SELF-ADHERING SELF-ADHERING SELF-ADHERING SELF-ADHERING SELF-ADHERING<br />

POS DRAIN POS DRAIN POS DRAIN<br />

X X X X X X X X X X<br />

X X X O O O O O O O<br />

X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X O O O O O O O<br />

X X X X X X X X X X<br />

X X X X X X X<br />

X X X X X X X<br />

X X X X X X X X X X<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

15 - 120 15 - 120 15 - 120 50 - 120 50 - 120 50 - 120 50 - 120 50 - 120 50 - 120 50 - 120<br />

SAME SAME SAME SELF-ADHESIVE SELF-ADHESIVE SELF-ADHESIVE SELF-ADHESIVE SELF-ADHESIVE SELF-ADHESIVE SELF-ADHESIVE<br />

MATERIAL MATERIAL MATERIAL TEXSELF CAP TEXSELF CAP TEXSELF CAP TEXSELF CAP TEXSELF CAP TEXSELF CAP TEXSELF CAP<br />

SHEET SHEET SHEET SHEET SHEET SHEET SHEET<br />

TORCH TORCH TORCH SELF-ADHERING SELF-ADHERING SELF-ADHERING SELF-ADHERING SELF-ADHERING SELF-ADHERING SELF-ADHERING<br />

NO NO NO NO NO NO NO NO NO NO<br />

SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN<br />

SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN SPAIN<br />

1991 1991 1995 1991 1999 1998 1991 1996 1996 1998<br />

THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT DISTRS/DIRECT<br />

CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE CUST SERVICE<br />

TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE<br />

165


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME TEXSA, TEXSA, TREMCO TREMCO TREMCO TREMCO<br />

SA SA INC. INC. INC. INC.<br />

2. PRODUCT NAME TEXSELF TEXSELF GS POWERPLY POWERPLY POWERPLY POWERPLY<br />

ALUMINIUM SUPREME SUPREME HE FR PREMIUM FR<br />

SMOOTH HT FR<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS SBS SBS/SEBS/SIS SBS/SEBS/SIS SBS SBS/SEBS/SIS<br />

Thickness (mils) 60 60 105 138 175 150<br />

Top Surface ALUMINIUM SMOOTH SMOOTH GRANULE GRANULE GRANULE<br />

FOIL<br />

Reinforcing Material ALUMINUM FOIL POLYESTER /<br />

FIBERGLASS<br />

POLYESTER /<br />

FIBERGLASS<br />

POLYESTER POLYESTER /<br />

FIBERGLASS<br />

Colors ALUMINIUM BLACK BLACK WHITE, BLACK,<br />

TAN<br />

WHITE<br />

WHITE, BLACK,<br />

TAN<br />

Installed Weight (lbs./ft 2 without ballast) 0.31 0.31 0.70 1.00 1.05 0.94<br />

4. KINDS OF FIELD SURFACING REQUIRED NONE NONE EMULSION NONE NONE NONE<br />

OR<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD SELF-ADHESIVE SELF-ADHESIVE HOT MOP / HOT MOP / HOT MOP HOT MOP<br />

COLD ADHESIVE COLD ADHESIVE OR COLD OR COLD<br />

GRAVEL<br />

ADHESIVE<br />

ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method) SELF-ADHERING SELF-ADHERING HOT OR COLD HOT OR COLD HOT OR COLD HOT OR COLD<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS. DRAINAGE POS. DRAINAGE<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber X X X X<br />

Mineral Fiber X X<br />

Polystyrene O O<br />

Cellular Glass X X<br />

Phenolic X X<br />

Fiberboard X X X X X X<br />

Perlite X X X X X X<br />

Polyisocyanurate X X O O O O<br />

Polythane X X O O O O<br />

Gypsum O O O O O O<br />

Concrete X X X X X X<br />

Wood Plank X X O O O O<br />

Plywood X X O O O O<br />

Existing Built-up Membrane X X O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 50 - 120 50 - 120 35 - 120 35 - 120 35 - 120 35 - 120<br />

12. FLASHING MATERIAL SELF-ADHESIVE SELF-ADHESIVE SAME, CSPE, SAME, CSPE, SAME, CSPE, OR SAME, CSPE,<br />

TEXSELF CAP TEXSELF CAP OR COMPATIBLE OR COMPATIBLE COMPATIBLE OR COMPATIBLE<br />

SHEET SHEET MATERIAL MATERIAL MATERIAL MATERIAL<br />

13. FLASHING METHOD SELF-ADHERING SELF-ADHERING HOT MOP HOT MOP HOT MOP HOT MOP<br />

OR COLD OR COLD OR COLD OR COLD<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin SPAIN SPAIN USA USA USA USA<br />

Manufacture SPAIN SPAIN USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1998 1994<br />

Within USA 1999 1999 1990 1997<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA THOUSANDS THOUSANDS<br />

Within USA<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS/DIRECT DISTRS/DIRECT DIRECT DIRECT DIRECT DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 14 14 14 14<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: CUST SERVICE CUST SERVICE SALES SALES SALES OFFICE SALES OFFICE<br />

OFFICE OFFICE<br />

22. TECHNICAL INFORMATION, CONTACT: TECH SERVICE TECH SERVICE TECHNICAL TECHNICAL TECH DEPT TECH DEPT<br />

DEPT.<br />

DEPT.<br />

23. SEE APPENDIX IF CHECKED<br />

166


Modified Bitumen Part 1 - General Information<br />

TREMCO TREMCO U.S. INTEC, U.S. INTEC, U.S. INTEC, U.S. INTEC, U.S. INTEC, U.S. INTEC, U.S. INTEC, U.S. INTEC,<br />

INC. INC. INC. INC. INC. INC. INC. INC. INC. INC.<br />

POWERPLY POWERPLY BRAI BRAI BRAI BRAI BRAI SUPREME BRAI SUPREME BRAI SUPREME BRAI SUPREME<br />

PREMIUM STANDARD SUPREME SUPREME SUPREME FR SUPREME SBS GLASS SBS POLY SBS POLY PLUS SBS POLY<br />

SMOOTH FR APP SMOOTH APP GRANULE APP GRANULE SBS GRANULE GRANULE FR SMOOTH GRANULE FR GRANULE FR<br />

SBS/SEBS SBS APP APP APP SBS SBS SBS SBS SBS<br />

80 120 160 160 160 160 180 138 160 177<br />

SMOOTH GRANULE MODIFIED GRANULES GRANULES GRANULES GRANULES SMOOTH GRANULES GRANULES<br />

BITUMEN<br />

POLYESTER /<br />

FIBERGLASS<br />

FIBERGLASS POLYESTER POLYESTER POLYESTER POLYESTER FIBERGLASS POLYESTER POLYESTER POLYESTER<br />

COMPOSITE<br />

BLACK<br />

WHITE, BLACK,<br />

TAN<br />

BLACK VARIOUS VARIOUS VARIOUS VARIOUS VARIOUS VARIOUS<br />

0.46 0.88 0.88 1.05 1.05 0.95 1.05 0.85 0.98 0.98<br />

EMULSION NONE ROOF COATING, NONE NONE NONE NONE CAP SHEET / NONE NONE<br />

OR GRANULE MOP /<br />

GRAVEL GRAVEL GRAVEL<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT MOP HOT MOP TORCH TORCH TORCH MOP / MOP / MOP / MOP / MOP /<br />

OR COLD OR COLD ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

ADHESIVE<br />

ADHESIVE<br />

HOT OR COLD HOT OR COLD TORCH TORCH TORCH HOT MOP HOT MOP MOP/ADHES MOP/ADHES MOP/ADHES<br />

POS. DRAINAGE POS. DRAINAGE POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN POS DRAIN<br />

X X O O O O O X O X X<br />

O O O O O X O X X<br />

O O O O O O O O<br />

O O O O O X O X O X O<br />

X X O O X X X<br />

X X O O O O O X X X<br />

O O O O O O O X O O O<br />

O O O O O O O X O O O<br />

O O O O O O O X O O O<br />

X X X O X O X O O O X O O O<br />

O O O O O O O X O O O<br />

O O O O O O O X O O O<br />

O O X O X O X O O O X O O O<br />

NONE NONE NONE NONE NONE SEE SPECS NONE NONE NONE NONE<br />

35 -120 35 - 120 40 – 120 40 – 120 40 – 120 40 – 120 40 -120 40 – 120 40 – 120 40 – 120<br />

SAME, CSPE, SAME, CSPE, SAME SAME SAME SAME SAME SAME SAME SAME<br />

OR COMPATIBLE OR COMPATIBLE MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL MATERIAL<br />

MATERIAL<br />

MATERIAL<br />

HOT MOP HOT MOP TORCH TORCH TORCH MOP / CEMENT MOP / CEMENT MOP / CEMENT MOP / CEMENT MOP / CEMENT<br />

OR COLD OR COLD<br />

ADHESIVE<br />

ADHESIVE<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA ITALY ITALY ITALY USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1961 1976 1976 1985 1985 1985 1990 1990<br />

1995 1990 1978 1983 1991 1985 1985 1985 1990 1990<br />

DIRECT DIRECT DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

14 14 9 9 9 9 9 9 9 9<br />

YES YES YES YES YES YES YES YES YES YES<br />

SALES OFFICE SALES OFFICE 800/231-4631 800/231-4631 800/231-4631 800/231-4631 800/231-4631 800/231-4631 800/231-4631 800/231-4631<br />

TECH DEPT TECH DEPT 800/624-6832 800/624-6832 800/624-6832 800/624-6832 800/231-6832 800/624-6832 800/624-6832 800/624-6832<br />

167


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME U.S. INTEC, W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN<br />

INC. SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS,<br />

INC. INC. INC. INC. INC.<br />

2. PRODUCT NAME INTEC PIKA PLY PREMIUM PIKA PLY WEATHER PLY WEATHER PLY<br />

MODIFIED SA-3 MA-4 SS3G (TG) MA MA FR<br />

BASE PLUS<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier SBS APP APP SBS APP APP<br />

Thickness (mils) 95 140 160 120 160 160<br />

Top Surface SMOOTH SMOOTH GRANULE SMOOTH GRANULE GRANULE<br />

Reinforcing Material FIBERGLASS POLYESTER POLYESTER FIBERGLASS POLYESTER POLYESTER<br />

Colors BLACK WHITE BLACK WHITE WHITE<br />

Installed Weight (lbs./ft 2 without ballast) 0.54<br />

4. KINDS OF FIELD SURFACING REQUIRED CAP SHEET / GRAVEL NONE GRAVEL NONE NONE<br />

MOP ALUMINUM ALUMINUM<br />

GRAVEL WHITE WHITE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD MOP / TORCH TORCH TORCH HOT MOP HOT MOP<br />

ADHESIVE<br />

COLD ADHESIVE COLD ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method) MOP/MECH FAS TORCH TORCH TORCH MOP/ADHESIVE MOP/ADHESIVE<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

X<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN X<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber X O O O O O<br />

Mineral Fiber<br />

X<br />

Polystyrene O O O O O O<br />

Cellular Glass X O O O O O O<br />

Phenolic<br />

Fiberboard X O O O O O<br />

Perlite X O O O O O<br />

Polyisocyanurate X O O O O O O<br />

Polythane X O O O O O O<br />

Gypsum X O O O O O O<br />

Concrete X O X X X X X<br />

Wood Plank X O O O O O O<br />

Plywood X O O O O O O<br />

Existing Built-up Membrane X O O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 40 – 120 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120<br />

12. FLASHING MATERIAL SAME SAME MATERIAL, SAME MATERIAL, SAME MATERIAL, SAME MATERIAL, SAME MATERIAL,<br />

MATERIAL HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA<br />

PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB<br />

13. FLASHING METHOD MOP / CEMENT TORCH TORCH TORCH HOT MOP HOT MOP<br />

COLD ADHESIVE COLD ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1989<br />

Within USA 1989 1985 1985 1985 1985 1985<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DIRECT DIRECT DIRECT DIRECT DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 9 5 5 5 5 5<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: 800/231-4631 C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD<br />

440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760<br />

22. TECHNICAL INFORMATION, CONTACT: 800/624-6832 K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI<br />

440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760<br />

23. SEE APPENDIX IF CHECKED<br />

168


Modified Bitumen Part 1 - General Information<br />

W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN<br />

SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS,<br />

INC. INC. INC. INC. INC. INC. INC. INC. INC. INC.<br />

PIKA PLY PIKA PLY PIKA PLY PIKA PLY PIKA PLY PIKA PLY PIKA PLY PIKA PLY PIKA PLY PIKA PLY<br />

MS-4 SS-4 MS-3G SS-3P S-3G SS-2 ALUMINUM MS-4 (TG) MS4G (TG) SS3P (TG)<br />

SBS SBS SBS SBS SBS SBS SBS SBS SBS SBS<br />

160 160 120 120 120 60 160 160 160 120<br />

GRANULE SAND GRANULE SAND SAND SAND ALUMINUM GRANULE GRANULE SMOOTH<br />

POLYESTER POLYESTER FIBERGLASS POLYESTER FIBERGLASS POLYESTER FIBERGLASS POLYESTER FIBERGLASS POLYESTER<br />

WHITE BLACK WHITE BLACK BLACK BLACK ALUMINUM WHITE WHITE BLACK<br />

NONE GRAVEL NONE GRAVEL GRAVEL GRAVEL NONE NONE NONE GRAVEL<br />

ALUMINUM ALUMINUM ALUMINUM ALUMINUM ALUMINUM<br />

WHITE WHITE WHITE WHITE WHITE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP TORCH TORCH TORCH TORCH<br />

COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE<br />

MOP/ADHESIVE MOP/ADHESIVE MOP/ADHESIVE MOP/ADHESIVE MOP/ADHESIVE MOP/ADHESIVE TORCH TORCH TORCH TORCH<br />

1:8 1:8 1:8 1:8 1:8 1:8 X<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

X X X X X X X X X X<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

35 - 120 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120<br />

SAME MATERIAL, SAME MATERIAL, SAME MATERIAL, SAME MATERIAL, SAME MATERIAL, SAME MATERIAL, SAME MATERIAL, SAME MATERIAL, SAME MATERIAL, SAME MATERIAL,<br />

HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA<br />

PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB<br />

MOP MOP MOP MOP MOP MOP TORCH TORCH TORCH TORCH<br />

COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1985 1985 1985 1985 1985 1985 1985 1985 1985 1985<br />

THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT<br />

5 5 5 5 5 5 5 5 5 5<br />

YES YES YES YES YES YES YES YES YES YES<br />

C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD<br />

440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760<br />

K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI<br />

440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760<br />

169


Modified Bitumen Part 1 - General Information<br />

1. COMPANY NAME W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN<br />

SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS,<br />

INC. INC. INC. INC. INC. INC.<br />

2. PRODUCT NAME PIKA PLY PIKA PLY PIKA PLY PIKA PLY PERFORMANCE PERFORMANCE<br />

MA-4 SA-4 808 808FR PLY PLY<br />

MS FR<br />

MS<br />

3. PRODUCT DESCRIPTION<br />

Type of Modifier APP APP SBS SBS SBS SBS<br />

Thickness (mils) 160 160 120 160 160 135<br />

Top Surface GRANULE SMOOTH SMOOTH GRANULE GRANULE GRANULE<br />

Reinforcing Material POLYESTER POLYESTER POLYESTER /<br />

FIBERGLASS<br />

POLYESTER /<br />

FIBERGLASS<br />

POLYESTER<br />

POLYESTER<br />

Colors WHITE BLACK BLACK WHITE WHITE WHITE<br />

Installed Weight (lbs./ft 2 without ballast)<br />

4. KINDS OF FIELD SURFACING REQUIRED NONE GRAVEL GRAVEL NONE NONE NONE<br />

ALUMINUM ALUMINUM<br />

WHITE WHITE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD TORCH TORCH HOT MOP HOT MOP HOT MOP HOT MOP<br />

COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE COLD ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS:<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method) TORCH TORCH MOP/ADHESIVE MOP/ADHESIVE MOP/ADHESIVE MOP/ADHESIVE<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X<br />

8. MINIMUM SLOPE REQUIRED X 1:8 1:8 1:8 1:8<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber O O O O O O<br />

Mineral Fiber<br />

Polystyrene O O O O O O<br />

Cellular Glass O O O O O O<br />

Phenolic<br />

Fiberboard O O O O O O<br />

Perlite O O O O O O<br />

Polyisocyanurate O O O O O O<br />

Polythane O O O O O O<br />

Gypsum O O O O O O<br />

Concrete X X X X X X<br />

Wood Plank O O O O O O<br />

Plywood O O O O O O<br />

Existing Built-up Membrane O O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120 35 - 120<br />

12. FLASHING MATERIAL SAME MATERIAL, SAME MATERIAL, SAME MATERIAL, SAME MATERIAL, SAME MATERIAL, SAME MATERIAL,<br />

HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA HYPALON OR PIKA<br />

PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB PLY FOIL MEMB<br />

13. FLASHING METHOD TORCH TORCH TORCH TORCH TORCH TORCH<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16, YEAR OF FIRST COMMERCIAL USE<br />

Outside USA<br />

Within USA 1985 1985 1985 1985 1985 1985<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 5 5 5 5 5 5<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD C. FITZGERALD<br />

440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760<br />

22. TECHNICAL INFORMATION, CONTACT: K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI K. BRZOZOWSKI<br />

440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760 440/248-7760<br />

23. SEE APPENDIX IF CHECKED<br />

170


Modified Bitumen Part 1 - General Information<br />

W.P. HICKMAN W.P. HICKMAN<br />

SYSTEMS, SYSTEMS,<br />

INC. INC.<br />

PERFORMANCE<br />

PLY<br />

SS<br />

PREMIUM<br />

CAP SHEET<br />

SBS<br />

SBS<br />

120 136<br />

SMOOTH GRANULE<br />

POLYESTER<br />

FIBERGLASS<br />

BLACK<br />

WHITE<br />

GRAVEL<br />

ALUMINUM<br />

WHITE<br />

NONE<br />

X<br />

X<br />

X<br />

X<br />

HOT MOP HOT MOP<br />

COLD ADHESIVE COLD ADHESIVE<br />

MOP/ADHESIVE MOP/ADHESIVE<br />

X<br />

X<br />

1:8 1:8<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

X<br />

X<br />

O<br />

O<br />

O<br />

O<br />

O<br />

O<br />

NONE<br />

NONE<br />

35 - 120 35 - 120<br />

SAME MATERIAL, SAME MATERIAL,<br />

HYPALON OR PIKA HYPALON OR PIKA<br />

PLY FOIL MEMB PLY FOIL MEMB<br />

TORCH TORCH<br />

YES<br />

USA<br />

USA<br />

YES<br />

USA<br />

USA<br />

1985 1985<br />

THOUSANDS<br />

DIRECT<br />

THOUSANDS<br />

DIRECT<br />

5 5<br />

YES<br />

YES<br />

C. FITZGERALD C. FITZGERALD<br />

440/248-7760 440/248-7760<br />

K. BRZOZOWSKI K. BRZOZOWSKI<br />

440/248-7760 440/248-7760<br />

171


APP Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME AMERICAN BITEC<br />

LUBRICANTS, INC.<br />

INC.<br />

2. PRODUCT NAME TIFFANY MDA<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing POLYESTER POLYESTER<br />

Top surface SMOOTH GRANULE<br />

4A. COMPLIES WITH:<br />

ASTM D 6222-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Materials Using Polyester Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

4B.<br />

ASTM D 6223-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Material Using Polyester and Glass Fiber Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

4C.<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER<br />

REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 140; Type II: 150 157<br />

Thickness (min., mils) Grade G Type I: 160; Type II: 170 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 70; Type II: 80<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 85; Type II: 100 110<br />

Bot<strong>to</strong>m coating thickness (min., mils) Type I: 30; Type II: 40 80<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF<br />

POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 140<br />

Thickness (min., mils) Grade G 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 75<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat conditioning, lbf.in., min. Type I: 50; Type II: 80 60.5<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. Type I: 23; Type II: 40 35<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 60; Type II: 90 180 93.1<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. Type I: 10; Type II: 15 64 21.8<br />

Elongation at 5% of max. load at 73.4 ±3.6 F, MD and XMD, % min. Type I: 30; Type II: 50 42.5<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 70; Type II: 80 102<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32 +7 15.8<br />

Dimensional stability, % change, max. 1 ≤1<br />

High temperature stability, F min. 230 250<br />

Granule embedment, Grade G only, max. loss, grams 2


APP Modified Bitumen Part 2: Test Results<br />

BITEC BITEC BITEC BITEC CELOTEX CELOTEX CERTAINTEED CERTAINTEED<br />

INC. INC. INC. INC. CORP. CORP. ROOFING ROOFING<br />

PRODUCTS PRODUCTS<br />

APS-4T APM-4T APM-4.5T COMPABASE CELOTEX APP CELOTEX APP FLINTASTIC FLINTASTIC<br />

FA-2T 4/S CAP SHEET 4M CAP SHEET STA STA PLUS 5.0<br />

POLYESTER POLYESTER POLYESTER FIBERGLASS POLYESTER POLYESTER POLYESTER POLYESTER<br />

SMOOTH GRANULE GRANULE SMOOTH SMOOTH GRANULE ALUMINUM ALUMINUM<br />

X<br />

X<br />

X<br />

160 157 160 200<br />

160 180 157<br />

90 88 100<br />

110 123<br />

80 80 90 60 80<br />

60.5 67 110 / 90 110 / 90<br />

35 6 63 / 68 63 / 68<br />

93.1 125 121 141 / 118 141 / 118<br />

21.8 46 38 19 / 23 19 / 23<br />

42.5 60 / 65 60 / 65<br />

102 149 147 100 100<br />

15.8 +14 +12 +19 8 8<br />

≤1 ≤1 ≤1 0.9 0.9 0.5 0.5<br />

250 250 250 250 250<br />


APP Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME CERTAINTEED CERTAINTEED<br />

ROOFING ROOFING<br />

PRODUCTS PRODUCTS<br />

2. PRODUCT NAME FLINTASTIC FLINTASTIC<br />

GTA GTA-FR<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing POLYESTER POLYESTER<br />

Top surface GRANULE GRANULE<br />

4A. COMPLIES WITH:<br />

ASTM D 6222-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Materials Using Polyester Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

4B.<br />

ASTM D 6223-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Material Using Polyester and Glass Fiber Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

4C.<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER<br />

REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 140; Type II: 150<br />

Thickness (min., mils) Grade G Type I: 160; Type II: 170 180 180<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 70; Type II: 80<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 85; Type II: 100 105 105<br />

Bot<strong>to</strong>m coating thickness (min., mils) Type I: 30; Type II: 40 60 60<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF<br />

POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 140<br />

Thickness (min., mils) Grade G 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 75<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat conditioning, lbf.in., min. Type I: 50; Type II: 80 106 / 92 106 / 92<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. Type I: 23; Type II: 40 57 / 62 57 / 62<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 60; Type II: 90 133 / 116 133 / 116<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. Type I: 10; Type II: 15 20 /22 20 /22<br />

Elongation at 5% of max. load at 73.4 ±3.6 F, MD and XMD, % min. Type I: 30; Type II: 50 62 / 65 62 / 65<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 70; Type II: 80 100 100<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32 +8 +8<br />

Dimensional stability, % change, max. 1 0.5 0.5<br />

High temperature stability, F min. 230 250 250<br />

Granule embedment, Grade G only, max. loss, grams 2 1.0 1.0<br />

Water absorption, % max. 3.2


APP Modified Bitumen Part 2: Test Results<br />

CERTAINTEED DERMABIT DERMABIT DIBITEN DIBITEN DIBITEN ECOLOGY ECOLOGY<br />

ROOFING WATER- WATER- ROOF ROOF<br />

PRODUCTS PROOFING PROOFING SYSTEMS SYSTEMS<br />

GTA BLACK DERMABIT DERMABIT DIBITTEN DIBITEN POLY DIBITEN ERS 600 ERS 601<br />

DIAMOND & 4170 SMOOTH 4170 GRANULE POLY/4 4.5 GRANULAR POLY/5<br />

WHITE DIAMOND<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

GRANULE SMOOTH GRANULE SMOOTH GRANULE SMOOTH SMOOTH GRANULE<br />

X<br />

X X X<br />

X X X<br />

160 160 200 160<br />

172 160 180 180<br />

90 75 85 75<br />

100 100 90 90<br />

70 40 40 80 80 100 80<br />

106 / 92 69 69 60 60 60 62 62<br />

57 / 62 38 38 25 25 25 25 25<br />

133 / 116 74 24 160 160 200 61 61<br />

20 / 22 10 10 22 21 22 28 28<br />

62 / 65 30 30 30 30 30 34 34<br />

105 90 90 84 100 118 88 88<br />

+8 +32 +32 +14 +23 +14 +33 +33<br />

0.5 1 1 0.1 0.1 0.1 0.01 2<br />

250 230 230 230 230 230 230 230<br />

2 2 2<br />


APP Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME FIRESTONE FIRESTONE<br />

BUILDINGS BUILDINGS<br />

PRODS. CO. PRODS. CO.<br />

2. PRODUCT NAME APP 160 APP 170<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing POLYESTER POLYESTER<br />

Top surface SMOOTH SMOOTH<br />

4A. COMPLIES WITH:<br />

ASTM D 6222-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Materials Using Polyester Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced) X X<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

4B.<br />

ASTM D 6223-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Material Using Polyester and Glass Fiber Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

4C.<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER<br />

REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 140; Type II: 150 150 165<br />

Thickness (min., mils) Grade G Type I: 160; Type II: 170<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 70; Type II: 80 82 90<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 85; Type II: 100<br />

Bot<strong>to</strong>m coating thickness (min., mils) Type I: 30; Type II: 40 50 51<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF<br />

POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 140<br />

Thickness (min., mils) Grade G 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 75<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat conditioning, lbf.in., min. Type I: 50; Type II: 80 62 62<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. Type I: 23; Type II: 40 38 32<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 60; Type II: 90 137 136<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. Type I: 10; Type II: 15 39 41<br />

Elongation at 5% of max. load at 73.4 ±3.6 F, MD and XMD, % min. Type I: 30; Type II: 50<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 70; Type II: 80 80 80<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32 +15 +15<br />

Dimensional stability, % change, max. 1 0.5 0.4<br />

High temperature stability, F min. 230 270 270<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2 0.5 0.5<br />

Moisture content, % max. 1 0.2 0.2<br />

Low temperature unrolling, F max. 41 10 10<br />

6B. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER<br />

REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat condtioning, lbf/in., min. Type I: 65: Type II: 100<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. 3<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 150; Type II: 200<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. 3<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 120; Type II: 180<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32<br />

Dimensional stability, % change, max. 1<br />

High temperature stability, F min. 230<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2<br />

Moisture content, % max. 1<br />

Low temperature unrolling, F max. 41<br />

7. SEE APPENDIX IF CHECKED<br />

176


APP Modified Bitumen Part 2: Test Results<br />

FIRESTONE FIRESTONE GAF GAF GAF GAF GAF GAF<br />

BUILDINGS BUILDINGS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS<br />

PRODS. CO. PRODS. CO. CORP. CORP. CORP. CORP. CORP. CORP.<br />

APP 180 APP 180 FR RUBEROID RUBEROID RUBEROID RUBEROID RUBEROID TRI-PLY<br />

TORCH TORCH TORCH PLUS TORCH FR TORCH 1 TP-4<br />

(SMOOTH) (GRANULE)<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

GRANULE GRANULE SMOOTH GANULE GRANULE GRANULE GRANULE SMOOTH<br />

X X X X<br />

X<br />

X<br />

X<br />

X<br />

149 140<br />

170 165 160 185 185 160 160<br />

70 70<br />

102 102 85 100 100 85 82<br />

51 49 30 30 40 40 30 30<br />

65 65 50 50 80 80 50 50<br />

52 43 40 40 40 40 40 23<br />

84 89 70 70 90 90 70 60<br />

17 16 15 15 15 15 10 10<br />

30 30 50 50 30 30<br />

90 85 70 70 80 80 70 70<br />

+10 +10 23 23 23 23 23 32<br />

0.5 0.6 1.0 1.0 1.0 1.0 1.0 1<br />

270 270 230 230 230 230 230 230<br />

1.0 1.3 NA 2 2 2 2 2<br />

3.2 3.2 3.2 3.2 3.2 3.2<br />

0.2 0.2 1.0 1.0 1.0 1.0 1.0 1<br />

10 10 41 41 41 41 41 41<br />

177


APP Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME GAF ICA, INC.<br />

MATERIALS<br />

CORP.<br />

2. PRODUCT NAME TRI-PLY ICA PREMIUM<br />

TP-4G APP SMOOTH<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing<br />

Top surface<br />

4A. COMPLIES WITH:<br />

ASTM D 6222-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Materials Using Polyester Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

4B.<br />

ASTM D 6223-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Material Using Polyester and Glass Fiber Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

4C.<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER<br />

REINFORCEMENTS<br />

POLYESTER<br />

SMOOTH<br />

Thickness (min., mils) Grade S Type I: 140; Type II: 150 140 160<br />

Thickness (min., mils) Grade G Type I: 160; Type II: 170 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 70; Type II: 80 70 88<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 85; Type II: 100 82<br />

Bot<strong>to</strong>m coating thickness (min., mils) Type I: 30; Type II: 40 30 60<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF<br />

POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 140<br />

Thickness (min., mils) Grade G 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 75<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat conditioning, lbf.in., min. Type I: 50; Type II: 80 50 85 / 85<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. Type I: 23; Type II: 40 23 45<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 60; Type II: 90 60 140<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. Type I: 10; Type II: 15 10 40<br />

Elongation at 5% of max. load at 73.4 ±3.6 F, MD and XMD, % min. Type I: 30; Type II: 50 30 50<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 70; Type II: 80 70 120<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32 32 +25<br />

Dimensional stability, % change, max. 1 1 0.5<br />

High temperature stability, F min. 230 230 275<br />

Granule embedment, Grade G only, max. loss, grams 2 2 2<br />

Water absorption, % max. 3.2 3.2 3<br />

Moisture content, % max. 1 1 1<br />

Low temperature unrolling, F max. 41 41 41<br />

6B. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER<br />

REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat condtioning, lbf/in., min. Type I: 65: Type II: 100<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. 3<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 150; Type II: 200<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. 3<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 120; Type II: 180<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32<br />

Dimensional stability, % change, max. 1<br />

High temperature stability, F min. 230<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2<br />

Moisture content, % max. 1<br />

Low temperature unrolling, F max. 41<br />

7. SEE APPENDIX IF CHECKED X<br />

X<br />

178


APP Modified Bitumen Part 2: Test Results<br />

ICA, INC. ICA, INC. IKO IKO JOHNS JOHNS JOHNS JOHNS<br />

INDUSTRIES INDUSTRIES MANVILLE MANVILLE MANVILLE MANVILLE<br />

INC. INC. INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL<br />

ICA PREMIUM ICA PREMIUM ARMOURPLAST ARMOURPLAST APPEX 4S TRICOR M-FR TRICOR S BICOR S<br />

APP MINERAL APP SLATE GRANULAR CLASSIC<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER COMBINATION COMBINATION COMBINATION<br />

GRANULE GRANULE GRANULE SMOOTH SMOOTH GRANULE SMOOTH SMOOTH<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

180 180 160<br />

160 160<br />

105 105 85<br />

60 80<br />

160 160<br />

180<br />

75 75<br />

90<br />

90 80 80<br />

85 / 85 85 74 74 60<br />

45 45 50 50 40<br />

120 120 80<br />

40 40 42<br />

50 50 35<br />

120 120 106 106 70<br />

+25 +25 +26 +26 +21<br />

0.5 0.5 0.35 0.35 0.9<br />

275 275 PASS PASS 230<br />

2 2 0.4 0.4<br />

3 3 0.5 0.5 0.7<br />

1 1 0.1 0.1 0.15<br />

41 41 PASS PASS 40<br />

X<br />

X<br />

150 150 100<br />

3 3 3<br />

300 300 200<br />

4.7 4.7 3.5<br />

260 260 163<br />

+23 +23 +23<br />

0 0 0<br />

240 240 240<br />

2<br />

1.3 1.3 1.3<br />

0.05 0.05 0.05<br />

40 40 40<br />

179


APP Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME JOHNS JOHNS<br />

MANVILLE MANVILLE<br />

INTERNATIONAL INTERNATIONAL<br />

2. PRODUCT NAME APPEX 4.5M APPEX 4.5M<br />

FR<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing POLYESTER POLYESTER<br />

Top surface GRANULE GRANULE<br />

4A. COMPLIES WITH:<br />

ASTM D 6222-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Materials Using Polyester Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced) X X<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

4B.<br />

ASTM D 6223-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Material Using Polyester and Glass Fiber Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

4C.<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER<br />

REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 140; Type II: 150<br />

Thickness (min., mils) Grade G Type I: 160; Type II: 170 180 180<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 70; Type II: 80<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 85; Type II: 100 90 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) Type I: 30; Type II: 40 70 70<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF<br />

POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 140<br />

Thickness (min., mils) Grade G 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 75<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat conditioning, lbf.in., min. Type I: 50; Type II: 80 60 60<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. Type I: 23; Type II: 40 25 25<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 60; Type II: 90 80 80<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. Type I: 10; Type II: 15 42 42<br />

Elongation at 5% of max. load at 73.4 ±3.6 F, MD and XMD, % min. Type I: 30; Type II: 50 35 35<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 70; Type II: 80 70 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32 +21 +21<br />

Dimensional stability, % change, max. 1 0.9 0.9<br />

High temperature stability, F min. 230 230 230<br />

Granule embedment, Grade G only, max. loss, grams 2 2 2<br />

Water absorption, % max. 3.2 1.8 2.1<br />

Moisture content, % max. 1 0.15 0.15<br />

Low temperature unrolling, F max. 41 40 40<br />

6B. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER<br />

REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat condtioning, lbf/in., min. Type I: 65: Type II: 100<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. 3<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 150; Type II: 200<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. 3<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 120; Type II: 180<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32<br />

Dimensional stability, % change, max. 1<br />

High temperature stability, F min. 230<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2<br />

Moisture content, % max. 1<br />

Low temperature unrolling, F max. 41<br />

7. SEE APPENDIX IF CHECKED<br />

180


APP Modified Bitumen Part 2: Test Results<br />

JOHNS KOPPERS KOPPERS MALARKEY MALARKEY MALARKEY MALARKEY PERFORMANCE<br />

MANVILLE INDUSTRIES, INDUSTRIES, ROOFING ROOFING ROOFING ROOFING ROOF<br />

INTERNATIONAL INC. INC. CO. CO. CO. CO. SYSTEMS INC.<br />

BICOR M 2040 2040 APP 159 APP 160 APP 161 APP 162 BITUTAK MB<br />

FR M S SMOOTH SMOOTH MINERAL MINERAL<br />

COMPOSITE NON-WOVEN POLY NON-WOVEN POLY FIBERGLASS POLYESTER POLYESTER POLYESTER POLYESTER<br />

GRANULE GRANULES SMOOTH SMOOTH SMOOTH GRANULE GRANULE SMOOTH<br />

X<br />

X<br />

X<br />

X<br />

160 80 157 150<br />

160 177 177<br />

45 90 89<br />

105 105<br />

45<br />

180<br />

90<br />

80<br />

75 70 70 70 80 / 80<br />

50 50 50 50 / 50<br />

105 121 120<br />

38 42 30<br />

50<br />

143 149 110<br />

+21 +21 -15 -15 -15 -15 +18<br />

0.9 0.9 0.5<br />

275<br />

1.1 1.5<br />

1.8 0.7 3<br />

0.15 0.15 1<br />

41<br />

100<br />

3<br />

200<br />

3<br />

180<br />

+23<br />

0<br />

240<br />

2<br />

1.3<br />

0.05<br />

40<br />

181


APP Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME PERFORMANCE PERFORMANCE<br />

ROOF ROOF<br />

SYSTEMS INC. SYSTEMS INC.<br />

2. PRODUCT NAME BITUTAK MB DERBIGUM<br />

MINERAL XPS FR<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing POLYESTER COMBINATION<br />

Top surface GRANULE SMOOTH<br />

4A. COMPLIES WITH:<br />

ASTM D 6222-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Materials Using Polyester Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

4B.<br />

ASTM D 6223-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Material Using Polyester and Glass Fiber Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

4C.<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER<br />

REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 140; Type II: 150<br />

Thickness (min., mils) Grade G Type I: 160; Type II: 170 168<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 70; Type II: 80<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 85; Type II: 100 100<br />

Bot<strong>to</strong>m coating thickness (min., mils) Type I: 30; Type II: 40 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF<br />

POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 140 160<br />

Thickness (min., mils) Grade G 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 75 96<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 110<br />

6A. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat conditioning, lbf.in., min. Type I: 50; Type II: 80 80 / 81<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. Type I: 23; Type II: 40 50 / 50<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 60; Type II: 90 120<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. Type I: 10; Type II: 15 20<br />

Elongation at 5% of max. load at 73.4 ±3.6 F, MD and XMD, % min. Type I: 30; Type II: 50 50<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 70; Type II: 80 110<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32 +18<br />

Dimensional stability, % change, max. 1 0<br />

High temperature stability, F min. 230 275<br />

Granule embedment, Grade G only, max. loss, grams 2 1.5<br />

Water absorption, % max. 3.2 3<br />

Moisture content, % max. 1 1<br />

Low temperature unrolling, F max. 41 41<br />

6B. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER<br />

REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat condtioning, lbf/in., min. Type I: 65: Type II: 100 100<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. 3 5<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 150; Type II: 200 220<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. 3 5<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 120; Type II: 180 180<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32 +23<br />

Dimensional stability, % change, max. 1 0.05<br />

High temperature stability, F min. 230 275<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2 3.2<br />

Moisture content, % max. 1 1<br />

Low temperature unrolling, F max. 41 41<br />

7. SEE APPENDIX IF CHECKED<br />

X<br />

X<br />

182


APP Modified Bitumen Part 2: Test Results<br />

PERFORMANCE PERFORMANCE PERFORMANCE PERFORMANCE PERFORMANCE PERFORMANCE PERFORMANCE POLYGLASS<br />

ROOF ROOF ROOF ROOF ROOF ROOF ROOF USA, INC.<br />

SYSTEMS INC. SYSTEMS INC. SYSTEMS INC. SYSTEMS INC. SYSTEMS INC. SYSTEMS INC. SYSTEMS INC.<br />

DERBICOLOR DERBICOLOR DERBIGUM DERBIGUM DERBIGUM DERBICOLOR DERBICOLOR POLYBOND<br />

XPS FR GP-FR GP GP-FR XPS XPS GP<br />

COMBINATION COMBINATION COMBINATION COMBINATION COMBINATION COMBINATION COMBINATION POLYESTER<br />

GRANULE GRANULE SMOOTH SMOOTH SMOOTH GRANULE GRANULE SMOOTH<br />

X<br />

X<br />

X<br />

X X<br />

X<br />

X<br />

X<br />

160<br />

81<br />

150 150 160<br />

180 180 180 180<br />

92 92 96<br />

110 110 110 110<br />

70 70 110 110 110 70 70<br />

50<br />

23<br />

100<br />

8<br />

30<br />

75<br />

+32<br />

0.5<br />

248<br />

≤3<br />

0.1<br />

41<br />

100 65 75 75 100 100 65<br />

5 4.5 4.5 4.5 5 5 4.5<br />

210 150 150 150 220 210 150<br />

5 4 4 4 5 5 4<br />

200 120 120 120 180 20 120<br />

+23 +23 +23 +23 +23 +23 +23<br />

0.05 0.05 0.05 0.05 0.05 0.05 0.05<br />

275 275 275 275 275 275 275<br />

1.5 1.5 1.5 1.5<br />

3.2 32 32 32 32 32 32<br />

1 1 1 1 1 1 1<br />

41 41 41 41 41 41 41<br />

183


APP Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME POLYGLASS POLYGLASS<br />

USA, NC. USA, NC.<br />

2. PRODUCT NAME POLYBOND G POLYFLEX<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing POLYESTER POLYESTER<br />

Top surface GRANULE SMOOTH<br />

4A. COMPLIES WITH:<br />

ASTM D 6222-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Materials Using Polyester Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

4B.<br />

ASTM D 6223-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Material Using Polyester and Glass Fiber Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

4C.<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER<br />

REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 140; Type II: 150 160<br />

Thickness (min., mils) Grade G Type I: 160; Type II: 170 180<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 70; Type II: 80 83<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 85; Type II: 100 95<br />

Bot<strong>to</strong>m coating thickness (min., mils) Type I: 30; Type II: 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF<br />

POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 140<br />

Thickness (min., mils) Grade G 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 75<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat conditioning, lbf.in., min. Type I: 50; Type II: 80 50 65<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. Type I: 23; Type II: 40 23 35<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 60; Type II: 90 100 100<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. Type I: 10; Type II: 15 8 10<br />

Elongation at 5% of max. load at 73.4 ±3.6 F, MD and XMD, % min. Type I: 30; Type II: 50 30 40<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 70; Type II: 80 75 90<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32 +32 +32<br />

Dimensional stability, % change, max. 1 0.5 0.5<br />

High temperature stability, F min. 230 248 248<br />

Granule embedment, Grade G only, max. loss, grams 2 ≤2 NA<br />

Water absorption, % max. 3.2 ≤3 3<br />

Moisture content, % max. 1 0.1 1<br />

Low temperature unrolling, F max. 41 41 41<br />

6B. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER<br />

REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat condtioning, lbf/in., min. Type I: 65: Type II: 100<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. 3<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 150; Type II: 200<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. 3<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 120; Type II: 180<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32<br />

Dimensional stability, % change, max. 1<br />

High temperature stability, F min. 230<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2<br />

Moisture content, % max. 1<br />

Low temperature unrolling, F max. 41<br />

7. SEE APPENDIX IF CHECKED<br />

X<br />

X<br />

184


APP Modified Bitumen Part 2: Test Results<br />

POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS<br />

USA, NC. USA, NC. USA, NC. USA, NC. USA, NC. USA, NC. USA, NC. USA, NC.<br />

POLYFLEX 5 POLYFLEX G POLYFLEX G-FR DIAMOND DUFLEX DUFLEX 5 DUFLEX G INSULROOFING<br />

BLACK<br />

POLYESTER POLYESTER POLYESTER POLYESTER COMBINATION COMBINATION COMBINATION POLYESTER<br />

SMOOTH GRANULE GRANULE GRANULE SMOOTH SMOOTH GRANULE SMOOTH<br />

X<br />

X X X<br />

X<br />

X<br />

X<br />

200 160<br />

180 180 160<br />

102<br />

97 97 87<br />

160 200<br />

83 102<br />

180<br />

97<br />

65 65 65 60<br />

35 35 35 25<br />

100 100 100 100 100<br />

10 10 10 8 10<br />

40 40 40 35<br />

90 80 80 75 80<br />

+32 +22 +22 +32 +22<br />

0.5 0.5 0.5 0.5 0.5<br />

248 248 248 248<br />

NA 2 2 2<br />

3 3 3 3<br />

1 0.1 0.1 0.1 0.1<br />

41 41 41 41<br />

65 65 65<br />

30 30 30<br />

100 100 100<br />

8 8 8<br />

120 120 120<br />

+22 +22 +22<br />

0.5 0.5 0.5<br />

245 248 248<br />

NA NA 2<br />

3 3 3<br />

0.1 0.1 0.1<br />

41 41 41<br />

185


APP Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME POLYGLASS POLYGLASS<br />

USA, NC. USA, NC.<br />

2. PRODUCT NAME INSULROOFING INSULBASE<br />

GRANULAR<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing POLYESTER POLYESTER<br />

Top surface SMOOTH SMOOTH<br />

4A. COMPLIES WITH:<br />

ASTM D 6222-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Materials Using Polyester Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

4B.<br />

ASTM D 6223-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Material Using Polyester and Glass Fiber Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

4C.<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER<br />

REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 140; Type II: 150 160 80<br />

Thickness (min., mils) Grade G Type I: 160; Type II: 170<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 70; Type II: 80<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 85; Type II: 100<br />

Bot<strong>to</strong>m coating thickness (min., mils) Type I: 30; Type II: 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF<br />

POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 140<br />

Thickness (min., mils) Grade G 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 75<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat conditioning, lbf.in., min. Type I: 50; Type II: 80<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. Type I: 23; Type II: 40<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 60; Type II: 90 100 60<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. Type I: 10; Type II: 15 10 2<br />

Elongation at 5% of max. load at 73.4 ±3.6 F, MD and XMD, % min. Type I: 30; Type II: 50<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 70; Type II: 80 80 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32 +22 +32<br />

Dimensional stability, % change, max. 1 0.5 0.01<br />

High temperature stability, F min. 230<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2<br />

Moisture content, % max. 1 0.1 0.1<br />

Low temperature unrolling, F max. 41<br />

6B. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER<br />

REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat condtioning, lbf/in., min. Type I: 65: Type II: 100<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. 3<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 150; Type II: 200<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. 3<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 120; Type II: 180<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32<br />

Dimensional stability, % change, max. 1<br />

High temperature stability, F min. 230<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2<br />

Moisture content, % max. 1<br />

Low temperature unrolling, F max. 41<br />

7. SEE APPENDIX IF CHECKED<br />

186


APP Modified Bitumen Part 2: Test Results<br />

POLYGLASS POLYGLASS SOUTHWESTERN SOUTHWESTERN TEXAS TEXSA, TEXSA, TEXSA,<br />

USA, NC. USA, NC. PETROLEUM PETROLEUM REFINERY SA SA SA<br />

CORPORATION CORPORATION CORP.<br />

DUFLEX POLYFLEX UNI+SHIELD SWEPCO MIGHTYPLATE MOPLY MOPLY MOPLY<br />

G-FR SA-P TRI-POLYMER UNI+SHIELD II FV 2 mm FV 3 mm FV 3 kg<br />

POLY/GLASS POLYESTER SMOOTH POLYESTER FIBERGLASS FIBERGLASS FIBERGLASS<br />

GRANULE GRANULE MOD. ASPH. SMOOTH SMOOTH SMOOTH SMOOTH<br />

X<br />

NA<br />

X<br />

NA NA NA<br />

160 157<br />

140<br />

80<br />

97<br />

40 80<br />

180<br />

97<br />

60<br />

80 120 104<br />

51 77 62<br />

>65 220 / 165 183 / 170<br />

>30 50 / 55 54 / 66<br />

>70 180<br />

>10 70 45<br />

>40<br />

>90 113 / 128 95<br />

120 NA NA NA<br />


APP Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME TEXSA, TEXSA,<br />

SA<br />

SA<br />

2. PRODUCT NAME MOPLY MOPLY<br />

FV 4 kg FP 3 kg<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing FIBERGLASS POLYESTER<br />

Top surface SMOOTH SMOOTH<br />

4A. COMPLIES WITH:<br />

ASTM D 6222-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Materials Using Polyester Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

4B.<br />

ASTM D 6223-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Material Using Polyester and Glass Fiber Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

4C.<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER<br />

REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 140; Type II: 150 104<br />

Thickness (min., mils) Grade G Type I: 160; Type II: 170<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 70; Type II: 80 62<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 85; Type II: 100<br />

Bot<strong>to</strong>m coating thickness (min., mils) Type I: 30; Type II: 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF<br />

POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 140 140<br />

Thickness (min., mils) Grade G 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 75 82<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat conditioning, lbf.in., min. Type I: 50; Type II: 80 72<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. Type I: 23; Type II: 40 35<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 60; Type II: 90 NA<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. Type I: 10; Type II: 15 NA<br />

Elongation at 5% of max. load at 73.4 ±3.6 F, MD and XMD, % min. Type I: 30; Type II: 50 NA<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 70; Type II: 80 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32 25<br />

Dimensional stability, % change, max. 1 1<br />

High temperature stability, F min. 230 230<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2 1<br />

Moisture content, % max. 1 1<br />

Low temperature unrolling, F max. 41 32<br />

6B. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER<br />

REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat condtioning, lbf/in., min. Type I: 65: Type II: 100 44<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. 3 3<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 150; Type II: 200 NA<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. 3 NA<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 120; Type II: 180 NA<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32 25<br />

Dimensional stability, % change, max. 1 0,5<br />

High temperature stability, F min. 230 230<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2 1<br />

Moisture content, % max. 1 1<br />

Low temperature unrolling, F max. 41 32<br />

7. SEE APPENDIX IF CHECKED<br />

NA<br />

NA<br />

188


APP Modified Bitumen Part 2: Test Results<br />

TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA,<br />

SA SA SA SA SA SA SA SA<br />

MOPLY MOPLY MOPLY MOPLY MOPLY MOPLY MOPLY MOPLY<br />

FP 4 kg FP 3 mm FP 4 mm FP 4 kg FP 5 kg FP 3 mm FP 4 mm FP 4 kg<br />

GARDEN MINERAL MINERAL MINERAL<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH GRANULE GRANULE GRANULE<br />

X NA X X X<br />

NA X X<br />

140 120 160 140 164<br />

82 77 98 82 102<br />

120 160 140<br />

77 98 82<br />

72 72 72 72 72 72 72 72<br />

35 35 35 35 35 35 35 35<br />

NA NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA NA<br />

70 70 70 70 70 70 70 70<br />

25 25 25 25 25 25 25 25<br />

1 1 1 1 1 1 1 1<br />

230 230 230 230 230 230 230 230<br />

1 1 1 1 1 1 1 1<br />

1 1 1 1 1 1 1 1<br />

32 32 32 32 32 32 32 32<br />

189


APP Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME TEXSA, TEXSA,<br />

SA<br />

SA<br />

2. PRODUCT NAME MOPLY MOPLY<br />

FP 5 kg FP 4 kg GARDEN<br />

MINERAL MINERAL<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing POLYESTER POLYESTER<br />

Top surface GRANULE GRANULE<br />

4A. COMPLIES WITH:<br />

ASTM D 6222-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Materials Using Polyester Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced) X X<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

4B.<br />

ASTM D 6223-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Material Using Polyester and Glass Fiber Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

4C.<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER<br />

REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 140; Type II: 150<br />

Thickness (min., mils) Grade G Type I: 160; Type II: 170 164 140<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 70; Type II: 80<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 85; Type II: 100 102 82<br />

Bot<strong>to</strong>m coating thickness (min., mils) Type I: 30; Type II: 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF<br />

POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 140<br />

Thickness (min., mils) Grade G 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 75<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat conditioning, lbf.in., min. Type I: 50; Type II: 80 72 72<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. Type I: 23; Type II: 40 35 35<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 60; Type II: 90 NA NA<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. Type I: 10; Type II: 15 NA NA<br />

Elongation at 5% of max. load at 73.4 ±3.6 F, MD and XMD, % min. Type I: 30; Type II: 50 NA NA<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 70; Type II: 80 70 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32 25 25<br />

Dimensional stability, % change, max. 1 1 1<br />

High temperature stability, F min. 230 230 230<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2 1 1<br />

Moisture content, % max. 1 1 1<br />

Low temperature unrolling, F max. 41 32 32<br />

6B. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER<br />

REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat condtioning, lbf/in., min. Type I: 65: Type II: 100<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. 3<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 150; Type II: 200<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. 3<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 120; Type II: 180<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32<br />

Dimensional stability, % change, max. 1<br />

High temperature stability, F min. 230<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2<br />

Moisture content, % max. 1<br />

Low temperature unrolling, F max. 41<br />

7. SEE APPENDIX IF CHECKED<br />

190


APP Modified Bitumen Part 2: Test Results<br />

TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA, TEXSA,<br />

SA SA SA SA SA SA SA SA<br />

TEXAL TEXAL TEXAL TEXAL TEXAL TEXAL TEXAL MOTERPLAS<br />

FV 3 kg FV 4 kg FP-S 3 kg FP-S 4 kg FP-S 3 mm FP-S 4 mm FP-S 4 kg POLIMERICA<br />

MINERAL PE 3 kg<br />

FIBERGLASS FIBERGLASS POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYETHIYLENE<br />

SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH GRANULE SMOOTH<br />

X<br />

NA X NA X NA<br />

NA<br />

NA<br />

104 140 120 160 104<br />

140<br />

62 82 77 98 62<br />

82<br />

104 140<br />

62 82<br />

89 89 89 89 89 19<br />

50 50 50 50 50 300<br />

NA NA NA NA NA NA<br />

NA NA NA NA NA NA<br />

NA NA NA NA NA NA<br />

90 90 90 90 90 15<br />

20 20 20 20 20 0<br />

1 1 1 1 1 2<br />

230 230 230 230 230 230<br />

2<br />

1 1 1 1 1 1<br />

1 1 1 1 1 1<br />

25 25 25 25 25 10<br />

44 44<br />

3 3<br />

NA<br />

NA<br />

NA<br />

NA<br />

NA<br />

NA<br />

20 20<br />

0,5 0,5<br />

230 230<br />

1 1<br />

1 1<br />

25 25<br />

191


APP Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME TEXSA, TEXSA,<br />

SA<br />

SA<br />

2. PRODUCT NAME MOTERPLAS MOTERPLAS<br />

POLIMERICA POLIMERICA<br />

PE 4 kg PE 4 mm<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing<br />

POLYETHIYLENE POLYETHIYLENE<br />

Top surface SMOOTH SMOOTH<br />

4A. COMPLIES WITH:<br />

ASTM D 6222-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Materials Using Polyester Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced) NA NA<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

4B.<br />

ASTM D 6223-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Material Using Polyester and Glass Fiber Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

4C.<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER<br />

REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 140; Type II: 150 140 160<br />

Thickness (min., mils) Grade G Type I: 160; Type II: 170<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 70; Type II: 80 82 98<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 85; Type II: 100<br />

Bot<strong>to</strong>m coating thickness (min., mils) Type I: 30; Type II: 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF<br />

POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 140<br />

Thickness (min., mils) Grade G 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 75<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat conditioning, lbf.in., min. Type I: 50; Type II: 80 19 19<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. Type I: 23; Type II: 40 300 300<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 60; Type II: 90 NA NA<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. Type I: 10; Type II: 15 NA NA<br />

Elongation at 5% of max. load at 73.4 ±3.6 F, MD and XMD, % min. Type I: 30; Type II: 50 NA NA<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 70; Type II: 80 15 15<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32 0 0<br />

Dimensional stability, % change, max. 1 2 2<br />

High temperature stability, F min. 230 230 230<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2 1 1<br />

Moisture content, % max. 1 1 1<br />

Low temperature unrolling, F max. 41 10 10<br />

6B. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER<br />

REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat condtioning, lbf/in., min. Type I: 65: Type II: 100<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. 3<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 150; Type II: 200<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. 3<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 120; Type II: 180<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32<br />

Dimensional stability, % change, max. 1<br />

High temperature stability, F min. 230<br />

Granule embedment, Grade G only, max. loss, grams 2<br />

Water absorption, % max. 3.2<br />

Moisture content, % max. 1<br />

Low temperature unrolling, F max. 41<br />

7. SEE APPENDIX IF CHECKED<br />

192


APP Modified Bitumen Part 2: Test Results<br />

U S INTEC, US INTEC, U S INTEC, W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN<br />

INC. INC. INC. SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS, SYSTEMS,<br />

INC. INC. INC. INC. INC.<br />

BRAI BRAI BRAI SUPREME PIKA PLY PREMIUM PIKA PLY PIKA PLY WEATHER PLY<br />

SUPREME SUPREME APP SA-3 MA-4 MA-4 SA-4 MA<br />

APP SMOOTH APP GRANULE GRANULE FR<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

SMOOTH GRANULE GRANULE SMOOTH GRANULE GRANULE SMOOTH GRANULE<br />

X X<br />

X X X X<br />

X<br />

X<br />

X<br />

140 140 160<br />

160 160 160 160 160<br />

70 >70 >70<br />

85 85 >85 >85<br />

30 30 30 >30 >30 >30<br />

50 50 50 >50 >50 >50 >50 >80<br />

40 40 40 >23 >23 >23 >23 >40<br />

70 70 70 >60 >60 >60 >60 >60<br />

15 15 15 10 10 10 >10<br />

30 30 30 >30 >30<br />

70 70 70 >70 >70 >70 >100 >80<br />

23 23 23


APP Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME W.P. HICKMAN<br />

SYSTEMS,<br />

INC.<br />

2. PRODUCT NAME WEATHER PLY<br />

MA FR<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing<br />

Top surface<br />

4A. COMPLIES WITH:<br />

ASTM D 6222-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Materials Using Polyester Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

4B.<br />

ASTM D 6223-98 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous<br />

Sheet Material Using Polyester and Glass Fiber Reinforcements (indicate type and grade, or NA)<br />

Type I, Grade G (granule surfaced)<br />

Type I, Grade S (smooth surfaced)<br />

Type II, Grade G (granule surfaced<br />

Type II, Grade S (smooth surfaced)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

4C.<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER<br />

REINFORCEMENTS<br />

POLYESTER<br />

GRANULE<br />

Thickness (min., mils) Grade S Type I: 140; Type II: 150<br />

Thickness (min., mils) Grade G Type I: 160; Type II: 170 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 70; Type II: 80<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 85; Type II: 100<br />

Bot<strong>to</strong>m coating thickness (min., mils) Type I: 30; Type II: 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF<br />

POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 140<br />

Thickness (min., mils) Grade G 160<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 75<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 73.4 ±3.6 F MD and XMD, before and after heat conditioning, lbf.in., min. Type I: 50; Type II: 80 >80<br />

Elongation at 73.4 ±3.6 MD and XMD, before and after heat conditioning, at max. load, % min. Type I: 23; Type II: 40 >23<br />

Maximum load at 0 ±3.6 F MD and XMD, lbf/in., min. Type I: 60; Type II: 90 >90<br />

Elongation at 0 ±3.6 F MD and XMD, at max. load, % min. Type I: 10; Type II: 15 >10<br />

Elongation at 5% of max. load at 73.4 ±3.6 F, MD and XMD, % min. Type I: 30; Type II: 50<br />

Tear strength at 73.4 ±3.6 F, lbf, min Type I: 70; Type II: 80 >80<br />

Low temperature flexibility, before and after heat conditioning, F, max. +32


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME BAKOR<br />

2. PRODUCT NAME MODIFIED PLUS<br />

G100s/s<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

GLASS<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B. ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

TYPE I<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE G<br />

4C.<br />

4D.<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

4E. CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

CLASS C<br />

GRADE 1<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45 51<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180 127<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2 4<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150 51<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 2.9<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2 12<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2 4<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210 83<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5 -15<br />

Dimensional stability, % max. 0.5 0.01<br />

Compound stability no failures PASS<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 1<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED X<br />

196


SBS Modified Bitumen Part 2: Test Results<br />

BAKOR BAKOR BAKOR BAKOR BAKOR BAKOR BAKOR BAKOR<br />

MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS<br />

G100p/s G100 p/p NP180 s/s NP 180 p/p NP 180 p/s G100gMFR 170 Mop Granule 170 Torch Granule<br />

GLASS GLASS Polyester Polyester Polyester Glass Polyester Polyester<br />

SMOOTH SMOOTH Smooth Smooth Smooth Granule Granule Granule<br />

TYPE I TYPE I Type I<br />

GRADE G GRADE G Grade G<br />

Type I Type I Type I Type I Type I<br />

Grade S Grade S Grade S Grade G Grade G<br />

CLASS C CLASS C Class C Class C Class C Class A Class A Class A<br />

GRADE 1 GRADE 1 Grade 2 Grade 2 Grade 2 Grade 1 Grade 1 Grade 1<br />

91 87 157<br />

56 57<br />

114<br />

N/A<br />

87 120 90<br />

157 159<br />

52 77 52<br />

99 92<br />

40 N/A 51<br />

132 160 102<br />

4.2 4.2 5.0<br />

44 41 53<br />

3 3.2 3.5<br />

16 20 19.5<br />

47 5 4.7<br />

90 96 93<br />

-10 0 0<br />

0.07 0.13 .06<br />

PASS PASS Pass<br />

.27<br />

88 88 90 116 102<br />

37 37 40 28 22<br />

68 68 73 61 65<br />

60 60 51 55 74<br />

43 43 40 51 66<br />

88 88 80 87 94<br />

-10 -10 -10 -10 -10<br />

.48 .24 .93 .34 .40<br />

Pass Pass Pass Pass Pass<br />

2.0 1.9<br />

X X X X X X X X<br />

197


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME BAKOR<br />

2. PRODUCT NAME MODIFIED PLUS<br />

NP180gM<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

Polyester<br />

Top surface (indicate granule, smooth or foil)<br />

Granule<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Type I<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

Grade G<br />

4D.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

4E. CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

Class A<br />

Grade 2<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130 157<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90 92<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 N/A<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 85<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 41<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 68<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 61<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60 40<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 91<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 -10<br />

Dimensional stability, % max. 1 .38<br />

Compound stability no failures Pass<br />

Granule embedment, Grade G only, max. grams 2 1.16<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED X<br />

198


SBS Modified Bitumen Part 2: Test Results<br />

BAKOR BAKOR BAKOR BAKOR BAKOR BAKOR BAKOR BITEC, INC.<br />

MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MDS<br />

NP 180 gT NP180gM FR NP180gT FR NP 250gM NP 250gT NP250gM FR NP 250gT FR<br />

Polyester Polyester Polyester Polyester Polyester Polyester Polyester POLYESTER<br />

Granule Granule Granule Granule Granule Granule Granule GRANULE<br />

TYPE I<br />

GRADE G<br />

Type I Type I Type I Type 2 Type 2 Type 2 Type 2<br />

Grade G Grade G Grade G Grade G Grade G Grade G Grade G<br />

Class A Class A Class A Class A Class A Class A Class A<br />

Grade 2 Grade 2 Grade 2 Grade 2 Grade 2 Grade 2 Grade 2<br />

160<br />

108<br />

55<br />

161 151 153 160 173 157 151<br />

102 108 103 95 104 107 99<br />

48 N/A 47 N/A 40 N/A 40<br />

76.7<br />

22.1<br />

60.4<br />

57.1<br />

60.4<br />

60.4<br />

84.5<br />

0<br />

≤1<br />

NO FAILURES<br />


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME BITEC, INC.<br />

2. PRODUCT NAME SPM-4.5T<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

Top surface (indicate granule, smooth or foil)<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

POLYESTER<br />

GRANULE<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE I<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE G<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130 180<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90 123<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 61<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 76.7<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 22.1<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 60.4<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 57.1<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60 60.4<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 84.5<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 0<br />

Dimensional stability, % max. 1 ≤1<br />

Compound stability no failures no failures<br />

Granule embedment, Grade G only, max. grams 2


SBS Modified Bitumen Part 2: Test Results<br />

BITEC, INC. BITEC, INC. BITEC, INC. BITEC, INC. BITEC, INC. BITEC, INC. BITEC, INC. BITEC, INC.<br />

SPM-3.5H SFM-3.5H SPM-4H SPM-4H/250 SPS-3H PS-2H FS-2H COMPAFLASH<br />

BFS-2H<br />

POLYESTER FIBERGLASS POLYESTER POLYESTER POLYESTER POLYESTER FIBERGLASS POLYESTER<br />

GRANULE GRANULE GRANULE GARNULE SMOOTH SMOOTH SMOOTH SMOOTH<br />

TYPE I<br />

GRADE G<br />

TYPE I TYPE I TYPE I TYPE I<br />

GRADE G GRADE G GRADE G GRADE S<br />

80<br />

140<br />

47<br />

100<br />

50 40<br />

120 80 80<br />

140 160 160<br />

73 47 47<br />

100 108 108 40<br />

50 55 55 50 40 20<br />

88.5<br />

2.7<br />

57.5 80<br />

3.9 6<br />

48.9<br />

34.5<br />

126<br />

0 +14<br />

0.06<br />

no failures<br />


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME BITEC, INC.<br />

2. PRODUCT NAME FS-2H-FR<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

Top surface (indicate granule, smooth or foil)<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

FIBERGLASS<br />

SMOOTH<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45 47<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150 80<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 6<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5 +14<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 1<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

202


SBS Modified Bitumen Part 2: Test Results<br />

BITEC, INC. BITEC, INC. BITEC, INC. BITEC, INC. BITEC, INC. CERTAINTEED CERTAINTEED CERTAINTEED<br />

SFM-3.5H-FR SFM-4H.FR FS-2H FS-25 FS-40 FLINTASTIC FLINTASTIC FLINTLASTIC<br />

PLUS GMS PREMIUM FR-P FR-P PREMIUM<br />

FIBERGLASS FIBERG;ASS FIBERGLASS FIBERGLASS FIBERGLASS POLYLESER POLYESTER POLYESTER<br />

GRANULE GRANULE SMOOTH SMOOTH GRANULE GRANULE GRANULE GRANULE<br />

TYPE I<br />

GRADE G<br />

TYPE I<br />

GRADE G<br />

TYPE II TYPE I TYPE II<br />

GRADE G GRADE G GRADE G<br />

88 40 60<br />

140 160<br />

60 25 40<br />

103 105<br />

55 55 40 20 30<br />

180 172 180<br />

105 105 105<br />

60 60 60<br />

91.3 91.3<br />

2.7 2.7<br />

57.5 57.5 70 75-60 75-60<br />

3.9 3.9 6 3 6<br />

48.9 48.9<br />

34.5 34.5<br />

126 126<br />

0 0 +14 +14 +14<br />

0.06 0.06<br />

no failures<br />

no failures<br />


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME CERTAINTEED<br />

2. PRODUCT NAME FLEX-I-GLAS FR<br />

BASE SHEET<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

FIBERGLASS<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B. ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

TYPE I<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80 92<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45 60<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 60<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180 90<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2 1.5<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150 65<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 2.5<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2 5<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2 5<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210 50<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5 -15<br />

Dimensional stability, % max. 0.5 0.1<br />

Compound stability no failures 250<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 1<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

204


SBS Modified Bitumen Part 2: Test Results<br />

CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED CERTAINTEED DANOSA<br />

FLINTASTIC POLY SMS BLACK DIAMOND FLEXIGLAS FLEXIGLAS FLINTLASTIC FLINTASTIC GLASDAN<br />

FR CAP BASE SHEET BASE SHEET BASE SHEET PREMIUM CAP 960 GTS GMS AL-80-3<br />

FIBERGLASS POLYESTER FIBERGLASS FIBERGLASS FIBERGLASS POLYESTER POLYESTER FIBERGLASS<br />

SMOOTH SMOOTH GRANULE SMOOTH GRANULE GRANULE GRANULE ALUMINUM<br />

TYPE I TYPE II<br />

GRADE G GRADE G<br />

TYPE II<br />

GRADE G<br />

TYPE I<br />

GRADE G<br />

80<br />

140 50 160<br />

30<br />

90 40 100<br />

60 20 30 60<br />

90 180 160<br />

45<br />

112 100<br />

40 80 60<br />

1343<br />

80<br />

40<br />

90 55 55 155<br />

1.5 1.5 1.5 3<br />

66 49 49 88<br />

2.5 3 3 5<br />

5 5 5 50<br />

5 5 5 40<br />

50 40 40 130<br />

-15 -20 -8 -5<br />

0.1 0.1 0.1 0.1<br />

250 250 250 250<br />

1.0 1.8<br />

103 134 103<br />

48 56 48<br />

70 94 70<br />

64 79 74<br />

70 83 70<br />

108 110 100<br />

100 -15 -15<br />

-15 0.5 0.5<br />

0.5 250 250<br />

250 2.0 2.0<br />

172<br />

3<br />

88<br />

5<br />

25<br />

125<br />

-5<br />

0.1<br />

230<br />

205


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME DANOSA<br />

2. PRODUCT NAME GLASDAN<br />

AL-80<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

FIBERGLASS<br />

Top surface (indicate granule, smooth or foil)<br />

ALUMINUM<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134 142<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80 96<br />

Back surface coating thickness (min., mils) 40 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 1<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160 172<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85 88<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25 25<br />

Tensile-tear strength, min., lbf. 120 125<br />

Low temperature flexibility, max., F 0 -5<br />

Dimensional stability, max., % 0.2 0.1<br />

Compound stability, min., F 225 230<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

206


SBS Modified Bitumen Part 2: Test Results<br />

DANOSA DANOSA DANOSA DANOSA DANOSA DANOSA DERMABIT DERMABIT<br />

GLASDAN ESTERDAN GLASDAN GLASDAN ESTERDAN ESTERDAN ELASPHALT 4170 ELASPHALT 4170<br />

R-36 R-36 RM-4 RM-5 RM-5 RM-PLUS SMOOTH GRANULE<br />

FIBRGLASS FIBERGLASS FIBERGLASS FIBERGLASS POLYESTER POLYESTER POLYESTER POLYESTER<br />

SMOOTH SMOOTH GRANULE GRANULE GRANULE GRANULE SMOOTH GRANULE<br />

TYPE II<br />

GRADE S<br />

TYPE II<br />

GRADE G<br />

130<br />

150 173<br />

80<br />

96 109<br />

40 40 40<br />

130 160<br />

157 196 160<br />

77<br />

109 100<br />

40 40 40<br />

72 72<br />

1 1<br />

44 66<br />

2 2<br />

72<br />

1<br />

44<br />

2<br />

37 37<br />

-4 -4<br />

0.1 0.1<br />

no falures<br />

no failues<br />

1.7 1.7<br />

37<br />

-4<br />

0.1<br />

no failures<br />

na<br />

125 125 150 70 70<br />

20 20 20 20 20<br />

110 110 132 50 50<br />

50 50 35 35<br />

38 55<br />

55 38<br />

-5 -5 -5 0 55<br />

0.1 0.5 0.5 1 0<br />

no failures no failures no failures no failures no failures<br />

1.7 1.7 2<br />

207


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME ECOLOGY<br />

2. PRODUCT NAME ERS 501<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

Top surface (indicate granule, smooth or foil)<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

POLYESTER<br />

SMOOTH<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE I<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115 130<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70 78<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 109.25<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 22<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 110<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 58<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60 74<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 148<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 0<br />

Dimensional stability, % max. 1 1<br />

Compound stability no failures no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

208


SBS Modified Bitumen Part 2: Test Results<br />

ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY<br />

ERS 502 EPS 503 ERS 504 ERS 505 ERS 507 ERS 602 ERS 603 ERS 604<br />

POLYESTER POLYESTER POLYESTER FIBERGLASS FIBERGLASS POLY/GLASS POLY/GLASS POLY/GLASS<br />

GRANULE SMOOTH GRANULE GRANULE GRANULE SMOOTH GRANULE GRANULE<br />

TYPE I<br />

GRADE G<br />

TYPE II TYPE II TYPE II TYPE II TYPE II<br />

GRADE S GRADE G GRADE S GRADE G GRADE G<br />

TYPE II<br />

TYPE II<br />

GRADE G<br />

GRADE G<br />

135 135<br />

160 160 160<br />

85 85<br />

85 85 85<br />

40 40 40 40 40<br />

120<br />

115<br />

78<br />

73<br />

40 40<br />

160<br />

78<br />

40<br />

128 128 128 128 128<br />

28 28 28 28 28<br />

96 96 96 96 96<br />

8 8 8 8 8<br />

86 86 86 86 86<br />

38 38 38 38 38<br />

120 120 120 120 120<br />

0 0 0 0 0<br />

0.7 0.7 0.7 0.7 0.7<br />

no failures no failures no failures no failures no failures<br />

4<br />

155 150<br />

3 3<br />

90 90<br />

6 6<br />

42 42<br />

24 24<br />

115 115<br />

0 0<br />

0.6 0.6<br />

no failures<br />

no failures<br />

4<br />

109.25<br />

22<br />

110<br />

58<br />

74<br />

148<br />

0<br />

1<br />

no failures<br />

4<br />

209


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME ECOLOGY<br />

2. PRODUCT NAME ERS 703<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

Top surface (indicate granule, smooth or foil)<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

FIBERGLASS<br />

ALUMINUM<br />

4B. ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

TYPE II<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE G<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120 150<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75 73<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150 90<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 4<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2 42<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2 20<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210 110<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5 0<br />

Dimensional stability, % max. 0.5 0.5<br />

Compound stability no failures no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 1<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

210


SBS Modified Bitumen Part 2: Test Results<br />

FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE<br />

SBS SBS PREMIUM SBS SMOOTH SBS SBS FR SBS PREMIUM SBS PREMIUM FR SBS TORCH<br />

BASE SHEET BASE SHEET<br />

FIBERGLASS FIBERGLASS POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

SMOOTH SMOOTH SMOOTH GRANULE GRANULE GRANULE GRANULE GRANULE<br />

TYPE II<br />

GRADE S<br />

TYPE I TYPE I TYPE I TYPE II TYPE II TYPE I<br />

GRADE S GRADE G GRADE G GRADE G GRADE G GRADE G<br />

90 90<br />

55 55<br />

145<br />

150 150 180 180 150<br />

86<br />

91 91 101 101 93<br />

46 40 40 42 40 42<br />

81 150<br />

45 3<br />

67 80<br />

62 6<br />

55 58<br />

64 23<br />

67 155<br />

-20 -10<br />

0.1 0.1<br />

250 250<br />

90 90 90 115 115 98<br />

30 25 25 37 35 31<br />

56 65 72 81 81 63<br />

52 53 53 56 54 56<br />

82 52 52 71 64 67<br />

115 80-10 80 110 105 93<br />

-10 0.2 -10 -10 -10 -10<br />

0.2 250 0.2 0.2 0.2 0.2<br />

250 1.0 250 250 250 250<br />

1.0 1.0 1.0 1.0<br />

211


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME FIRESTONE<br />

2. PRODUCT NAME SBS FLASHING<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

Top surface (indicate granule, smooth or foil)<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

POLYESTER<br />

GRANULE<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE I<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE G<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130 150<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90 91<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 41<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 90<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 27<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 67<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 39<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60 53<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 85<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 -10<br />

Dimensional stability, % max. 1 0.2<br />

Compound stability no failures 250<br />

Granule embedment, Grade G only, max. grams 2 1.0<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

212


SBS Modified Bitumen Part 2: Test Results<br />

FIRESTONE FIRESTONE FIRESTONE FIRESTONE GAF GAF GAF<br />

SBS GLASS SBS POLY SBS FR SBS METAL SBS POLY RUBEROID MOP RUBEROID MOP RUBEROID MOP<br />

TORCH BASE TORCH BASE TORCH FLASH AL BASE PLUS FR (GRANULE)<br />

FIBERGLASS POLYESTER POLYESTER FIBERGLASS POLYESTER POLYESTER POLYESTER POLYESTER<br />

GRANULE SMOOTH GRANULE ALUMINUM SMOOTH GRANULE GRANULE GRANULE<br />

TYPE I TYPE I TYPE I TYPE I TYPE II TYPE II TYPE I<br />

GRADE S GRADE S GRADE G GRADE S GRADE S GRADE S GRADE G<br />

X<br />

120<br />

82<br />

51<br />

120<br />

175 145 145 145<br />

82 120 90 90 75<br />

54 50 40 40 40<br />

150<br />

91<br />

45<br />

105<br />

5<br />

55<br />

5<br />

53<br />

17<br />

77<br />

-5<br />

0.1<br />

250<br />

93 96 81 100 100 70<br />

40 22 45 20 20 20<br />

61 70 67 70 70 50<br />

53 53 62 50 50 40<br />

68 80 64 60 60 40<br />

85 85 67 70 70 70<br />

-10 -10 -10 0 0 0<br />

0.2 0.3 0.3 1.0 1.0 1.0<br />

250 250 250 215 215 215<br />

1.0 2 2 2<br />

170<br />

8.5<br />

120<br />

7.0<br />

140<br />

160<br />

-10<br />

0.1<br />

250<br />

213


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME GAF<br />

2. PRODUCT NAME RUBEROID MOP<br />

170 FR<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

POLYESTER<br />

Top surface (indicate granule, smooth or foil)<br />

GRANULE<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE I<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE G<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130 145<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 70<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 50<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 40<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60 40<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 0<br />

Dimensional stability, % max. 1 1.0<br />

Compound stability no failures 215<br />

Granule embedment, Grade G only, max. grams 2 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

214


SBS Modified Bitumen Part 2: Test Results<br />

GAF GAF GAF GAF GAF GAF GAF GAF<br />

RUBEROID RUBEROID RUBEROID RUBEROID MOP RUBERIOD SBS HW RUBEROID SBS HW RUBEROID SBS HW RUBEROID SBS HW<br />

20 30 30 FR (SMOOTH) (SMOOTH) (GRANULES) (FR) (PLUS)<br />

FIBERGLASS FIBERGLASS FIBERGLASS POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

SMOOTH GRANULE GRANULE SMOOTH SMOOTH GRANULE GRANULE GRANULE<br />

TYPE I TYPE I TYPE I<br />

GRADE S GRADE G GRADE G<br />

TYPE I TYPE I TYPE I TYPE I TYPE II<br />

GRADE S GRADE S GRADE G GRADE G GRADE G<br />

80<br />

160 130<br />

45<br />

65 65<br />

NA NA NA<br />

140 149<br />

145 145 145<br />

54 54<br />

75 75 90<br />

40 40 40 40 40<br />

70 70 70<br />

2 2 2<br />

30 40 40<br />

2 2 2<br />

3 3 3<br />

3 3 3<br />

40 40 40<br />

0 0 0<br />

0.5 0.5 0.5<br />

215 215 215<br />

NA 2 2<br />

70 70 70 70 100<br />

20 20 20 20 20<br />

50 50 50 50 70<br />

40 40 40 40 50<br />

40 40 40 40 60<br />

70 70 70 70 70<br />

0 0 0 0 0<br />

1.0 1.0 1.0 1.0 1.0<br />

215 215 215 215 215<br />

NA NA 2 2 2<br />

215


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME GAF<br />

2. PRODUCT NAME RUBEROID SBS HW<br />

(PLUS FR)<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

POLYESTER<br />

Top surface (indicate granule, smooth or foil)<br />

GRANULE<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE II<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE G<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130 145<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 0<br />

Dimensional stability, % max. 1 1.0<br />

Compound stability no failures 215<br />

Granule embedment, Grade G only, max. grams 2 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

216


SBS Modified Bitumen Part 2: Test Results<br />

GAF GAF GAF GARLAND GARLAND GARLAND GARLAND GARLAND<br />

MODIFIED CAP ULTRACLAD TRI-PLY SBS STRESS PLY STRESSPLY STRESSPLY FR STRESSPLY FR VERSIPLY<br />

SHEET 601+ SBS GRANULE MINERAL MINERAL 40<br />

FIBERGLASS FIBERGLASS POLYESTER FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS<br />

GRANULE FOIL GRANULE SMOOTH GRANULE SMOOTH GRANULE SMOOTH<br />

TYPEI TYPE II TYPE III TYPE III TYPE III TYPE III<br />

GRADE G GRADE S GRADE S GRADE G GRADE S GRADE G<br />

TYPE I<br />

GRADE G<br />

80 80 80 40<br />

130 135 135<br />

45 85 85 45<br />

65 105 110<br />

NA<br />

NA<br />

85<br />

130<br />

54<br />

75<br />

40<br />

125<br />

2<br />

80<br />

4<br />

75<br />

30<br />

90<br />

0<br />

0.5<br />

225<br />

NA<br />

70 240 250 230 240 210<br />

2 3.0 3.0 3.0 3.0 3.0<br />

40 220 210 220 215 205<br />

2 4.0 4.0 4.0 4.0 3.7<br />

3<br />

3<br />

40 250 250 250 240 280<br />

0 -40 -20 -15 -5 -20<br />

0.5


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME GARLAND<br />

2. PRODUCT NAME VERSIPLY<br />

60<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

FIBERGLASS<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80 60<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180 210<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2 3.0<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150 210<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 3.7<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210 300<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5 -20<br />

Dimensional stability, % max. 0.5


SBS Modified Bitumen Part 2: Test Results<br />

GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND<br />

VERSIPLY VERSIPLY STRESSPLY STESSPLY STRESSPLY STERSSPLY PLUS STRESSPLY STRESSPLY IV<br />

80 MINERAL PLUS PLUS MINERAL PLUS FR FR MINERAL IV MINERAL<br />

FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS<br />

SMOOTH GRANULE SMOOTH SMOOTH SMOOTH GRANULE SMOOTH GRANULE<br />

TYPE III TYPE III TYPE III TYPE III TYPE III TYPE III TYPE III TYPE III<br />

GRADE S GRADE G GRADE S GRADE G GRADE S GRADE G GRADE S GRADE G<br />

80 80 80 180<br />

135 135 135 195<br />

80 80 85 145<br />

105 105 110 160<br />

40 40<br />

240 240 240 250 230 240 240 240<br />

3.0 3.0 3.0 3.0 3.0 3.0 4.0 4.0<br />

205 220 220 210 220 215 210 210<br />

3.0 3.0 4.0 4.0 4.0 4.0 5.5 5.5<br />

325 325 250 250 250 240 250 250<br />

-30 -25 -30 -25 -15 -10 -10 -10<br />


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME GARLAND<br />

2. PRODUCT NAME STRESSPLY<br />

E<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

COMBINATION<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE III<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55 80<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250 650<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2 4.5<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250 500<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 5.5<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280 900<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 -25<br />

Dimensional stability, % max. 0.5


SBS Modified Bitumen Part 2: Test Results<br />

GARLAND GARLAND GARLAND HENRY CO. HENRY CO. HENRY CO. HENRY CO. HENRY CO.<br />

STRESSPLY E STRESSPLY E STRESSPLY E MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS<br />

MINERAL FR FR MINERAL G100s/s G100 p/s G100 p/p NP180 s/s NP 180 p/p<br />

COMBINATION COMBINATION COMBINATION Glass Glass Glass Polyester Polyester<br />

GRANULE SMOOTH GRANULE Smooth Smooth Smooth Smooth Smooth<br />

Type 1 Type 1 Type 1<br />

Grade S Grade S Grade S<br />

TYPE III TYPE III TYPE III Type I Type I<br />

GRADE G GRADE S GRADE G Grade S Grade S<br />

80<br />

135 135<br />

85<br />

105 110<br />

Class C Class C Class C Class C Class C<br />

Grade 1 Grade 1 Grade 1 Grade 2 Grade 2<br />

80 91 87<br />

51 56 57<br />

87 120<br />

52 77<br />

40<br />

650 600 600<br />

4.5 4.5 4.5<br />

500 475 475<br />

5.5 5.5 5.5<br />

900 900 900<br />

-25 -25 -25<br />


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME HENRY CO.<br />

2. PRODUCT NAME MODIFIED PLUS<br />

NP 180 p/s<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

Polyester<br />

Top surface (indicate granule, smooth or foil)<br />

Smooth<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Type I<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

Grade S<br />

4D.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

4E. CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

Class C<br />

Grade 2<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115 90<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70 52<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 90<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 40<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 73<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 51<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60 40<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 80<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 -10<br />

Dimensional stability, % max. 1 .93<br />

Compound stability no failures Pass<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED X<br />

222


SBS Modified Bitumen Part 2: Test Results<br />

HENRY CO. HENRY CO. HENRY CO. HENRY CO. HENRY CO. HENRY CO. HENRY CO. HENRY CO.<br />

MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS MODIFIED PLUS<br />

G100gMFR 170 Mop Granule 170 Torch Granule NP180gM NP 180 gT NP180gM FR NP180gT FR NP 250gM<br />

Glass Polyester Polyester Polyester Polyester Polyester Polyester Polyester<br />

Granule Granule Granule Granule Granule Granule Granule Granule<br />

Type I<br />

Grade G<br />

Type I Type I Type I Type I Type I Type I Type 2<br />

Grade G Grade G Grade G Grade G Grade G Grade G Grade G<br />

Class A Class A Class A Class A Class A Class A Class A Class A<br />

Grade 1 Grade 1 Grade 1 Grade 2 Grade 2 Grade 2 Grade 2 Grade 2<br />

157<br />

114<br />

N/A<br />

157 159 157 161 151 153 160<br />

99 92 92 102 108 103 95<br />

N/A 51 N/A 48 N/A 47 N/A<br />

102<br />

5.0<br />

53<br />

3.5<br />

19.5<br />

4.7<br />

93<br />

0<br />

.06<br />

Pass<br />

.27<br />

116 102 85 100 72 81 103<br />

28 22 41 38 40 36 40<br />

61 65 68 65 65 61 72<br />

55 74 61 57 84 76 61<br />

51 66 40 40 45 45 60<br />

87 94 91 92 91 92 122<br />

-10 -10 -10 -10 0 -5 -10<br />

.34 .40 .38 .47 .60 .40 .46<br />

Pass Pass Pass Pass Pass Pass Pass<br />

2.0 1.9 1.16 1.20 .18 1.05 1.03<br />

X X X X X X X X<br />

223


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME HENRY<br />

2. PRODUCT NAME MODIFIED PLUS<br />

NP 250gT<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

Polyester<br />

Top surface (indicate granule, smooth or foil)<br />

Granule<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Type 2<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

Grade G<br />

4D.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

4E. CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

Class A<br />

Grade 2<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130 173<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90 104<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 127<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 46<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 88<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 52<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 121<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 -15<br />

Dimensional stability, % max. 1 .32<br />

Compound stability no failures Pass<br />

Granule embedment, Grade G only, max. grams 2 1.20<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED X<br />

224


SBS Modified Bitumen Part 2: Test Results<br />

HENRY CO. HENRY CO. IKO IKO IKO IKO IKO IKO<br />

MODIFIED PLUS MODIFIED PLUS MODIFLEX MODIFLEX MODIFLEX MODIFLEX MODIFLEX MODIFLEX<br />

NP250gM FR NP 250gT FR MP-180-CAP MP-250-CAP TP-180-CAP MF-95-FS BASE MP-180-FS-BASE MP-180-SS-BASE<br />

Polyester Polyester POLYESTER POLYESTER POLYESTER FIBERGLASS POLYESTER POLYESTER<br />

Granule Granule GRANULE GRANULE GRANULE SMOOTH SMOOTH SMOOTH<br />

TYPE I<br />

GRADE S<br />

Type 2 Type 2 TYPE I TYPE II TYPE I TYPE I TYPE I<br />

Grade G Grade G GRADE G GRADE G GRADE G GRADE S GRADE S<br />

Class A<br />

Class A<br />

Grade 2 Grade 2<br />

87<br />

52<br />

87<br />

157 151 138 158 158 157<br />

54<br />

107 99 79 96 97 97<br />

N/A 40<br />

55<br />

4<br />

73<br />

-26<br />

0.0<br />

no failures<br />

100 100<br />

39 44<br />

88 83 70 115 70 70 70<br />

85 75 50 51 50 55 55<br />

65 60<br />

88 121 85 123 85 75 75<br />

-10 0 -5 -10 -5 -5 -5<br />

.30 .90 0.35 0.35 0.35 0.35 0.35<br />

Pass Pass no failures no failures no failures no failures no failures<br />

1.11 .13 0.4 0.4 0.4<br />

X<br />

X<br />

225


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME IKO<br />

2. PRODUCT NAME TORCHFLEX<br />

TP-250-CAP<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

POLYESTER<br />

Top surface (indicate granule, smooth or foil)<br />

GRANULE<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE II<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE G<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130 197<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90 119<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 107<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 123<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 -5<br />

Dimensional stability, % max. 1 0.35<br />

Compound stability no failures no failures<br />

Granule embedment, Grade G only, max. grams 2 0.4<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

226


SBS Modified Bitumen Part 2: Test Results<br />

IKO IKO IKO IKO IKO IKO IKO IKO<br />

TORCHFLEX MODIFLEX TORCHFLEX TORCHFLEX TORCHFLEX ARMOUR BOND ARMOUR BOND ARMOUR<br />

TP-250-CAP (5mm) MF-95-SS-BASE TF-95-FF-BASE TF-95-FF-BASE (22) TP-180-FF-BASE 95 180 BRIDGE/PONT<br />

POLYESTER FIBERGLASS FIBERGLASS FIBERGLASS POLYESTER FIBERGLASS POLYESTER POLYESTER<br />

GRANULE SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH GRANULE<br />

TYPE I TYPE I TYPE I TYPE I<br />

GRADE S GRADE S GRADE S GRADE S<br />

TYPE II TYPE I TYPE I TYPE I<br />

GRADE G GRADE S GRADE S GRADE G<br />

87 118 87 98<br />

53 74 54 58<br />

118 118<br />

196 217<br />

71 69<br />

119 133<br />

55 55 55 55<br />

4 4 4 4<br />

73 73 73 73<br />

-22 -22 -22 -22<br />

0.0 0.0 0.0 0.0<br />

no failures no failures no failures no failures<br />

107 70 70 70<br />

50 50 50 50<br />

123 85 85<br />

-5 -5 -5 -5<br />

0.35 0.35 0.35 0.35<br />

no failures no failures no failures no failures<br />

0.4 0.4<br />

227


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME IKO<br />

2. PRODUCT NAME ARMOUR GARD<br />

ICE & WATER<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

FIBERGLASS<br />

Top surface (indicate granule, smooth or foil)<br />

SAND<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120 71<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75 37<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150 45<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 4<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5 -22<br />

Dimensional stability, % max. 0.5 0.0<br />

Compound stability no failures 212<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 1<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

228


SBS Modified Bitumen Part 2: Test Results<br />

JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE<br />

DYNAGLAS DYNAPLY DYNAGLAS FR DYNALASTIC DYNALASTIC DYNALASTIC DYNAGLAS DYNABASE<br />

250 180 180 FR 30 FR<br />

FIBERGLASS COMBINATION FIBERGLASS POLYESTER POLYESTER POLYESTER FIBERGLASS FIBERGLASS<br />

GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE<br />

TYPE II<br />

GRADE S<br />

TYPE I TYPE I TYPE I TYPE I<br />

GRADE G GRADE G GRADE G GRADE S<br />

TYPE II TYPE I TYPE I<br />

GRADE G GRADE G GRADE G<br />

125<br />

87<br />

150 160 140 100<br />

90 100 90 50<br />

160 150 150<br />

100 100 100<br />

125<br />

4<br />

80<br />

6<br />

75<br />

125<br />

125<br />

-10<br />

0.2<br />

no failures<br />

95 95 85 70<br />

4 4 3 4<br />

58 55 50 41<br />

5 5 5 5<br />

8 8 6 6<br />

5 5 4 4<br />

100 100 90 90<br />

-10 -10 -10 -10<br />

0.2 0.2 0.2 0.2<br />

no failures no failures no failures no failures<br />

2 2 2<br />

115 80 80<br />

45 35 35<br />

125 54 50<br />

94 57 48<br />

60 40 40<br />

120 80 80<br />

-10 -10 -10<br />

0.7 0.7 0.7<br />

no failures no failures no failures<br />

2 2 2<br />

229


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME JOHNS MANVILLE<br />

2. PRODUCT NAME DYNALASTIC<br />

180S<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

POLYESTER<br />

Top surface (indicate granule, smooth or foil)<br />

GRANULE<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE I<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130 118<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 80<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 35<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 54<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 57<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60 40<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 80<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 -10<br />

Dimensional stability, % max. 1 0.7<br />

Compound stability no failures no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

230


SBS Modified Bitumen Part 2: Test Results<br />

JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE JOHNS MANVILLE<br />

DYNALASTIC DYNAMAX DYNAMAX FR DYNAKAP DYNAKAP DYNACLAD DYNAWELD DYNAWELD<br />

250 FR FR BASE CAP FR<br />

POLYESTER COMBINATION COMBINATION COMBINATION COMBINATION FIBERGLASS FIBERGLASS FIBERGLASS<br />

GRANULE GRANULE GRANULE GRANULE GRANULE FOIL SMOOTH GRANULE<br />

TYPE III TYPE III TYPE II TYPE II<br />

GRADE G GRADE G GRADE E GRADE E<br />

TYPE II<br />

GRADE G<br />

X<br />

TYPE I<br />

GRADE S<br />

TYPE I<br />

GRADE G<br />

160 180 160 160<br />

99 115 115 115<br />

120<br />

90<br />

160<br />

40 40<br />

160<br />

100<br />

160<br />

100<br />

40<br />

300 300 150 150<br />

4 4 4 4<br />

308 308 81 81<br />

7 7 5 5<br />

100 100 75 75<br />

50 50 30 30<br />

350 350 125 125<br />

-20 -15 -10 -10<br />

0.2 0.2 0.2 0.2<br />

no failures no failures no failures no failures<br />

2 2 2 2<br />

70 95<br />

4 4<br />

41 55<br />

5 5<br />

6 8<br />

4 5<br />

90 100<br />

-10 -10<br />

0.2 0.2<br />

no failures<br />

no failures<br />

2<br />

15<br />

45<br />

125<br />

90<br />

60<br />

120<br />

-10<br />

0.7<br />

no failures<br />

2<br />

160<br />

3<br />

85<br />

5<br />

25<br />

120<br />

0<br />

0.2<br />

225<br />

231


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME KOPPERS<br />

2. PRODUCT NAME 2041 M<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

Top surface (indicate granule, smooth or foil)<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

POLYESER<br />

GRANULE<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE I<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE G<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130 150<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 80<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 35<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 54<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 57<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 80<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 -10<br />

Dimensional stability, % max. 1 4.7<br />

Compound stability no failures no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

232


SBS Modified Bitumen Part 2: Test Results<br />

KOPPERS KOPPERS KOPPERS KOPPERS MALARKEY MALARKEY MALARKEY<br />

2041 S 2041 MFR 2045 M 2045 MFR PREMIUM SBS PARAGON PANOPLY<br />

601 SBS 625 SBS 650<br />

POLYESTER POLYESTER POLYESTER POLYESTER COMBINATION FIBERGLASS FIBERGLASS<br />

SMOOTH GRANULE GRANULE GRANULE GRANULE GRANULE GRANULE<br />

TYPE I TYPE I TYPE I TYPE II<br />

GRADE S GRADE G GRADE G GRADE G<br />

TYPE I<br />

GRADE G<br />

120<br />

102<br />

125 150<br />

102 120<br />

118<br />

150 158 160<br />

101 118 115<br />

100<br />

4<br />

90<br />

0.5<br />

110 200<br />

65 105<br />

4 4<br />

0.5 0.5<br />

80 80 115 115<br />

35 35 45 45<br />

54 50 125<br />

57 48 94 62<br />

80 80 120 120<br />

-10 -10 -10 -10<br />

4.7 0.7 4.7 0.7<br />

no failures no failures no failures no failures<br />

233


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME POLYGLASS<br />

2. PRODUCT NAME ELASTOSHIELD<br />

TS 4<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

POLYESTER<br />

Top surface (indicate granule, smooth or foil)<br />

GRANULE<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE I<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE G<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130 180<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 100<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 85<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 30<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 60<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 45<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60 50<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 80<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 -5<br />

Dimensional stability, % max. 1 0.5<br />

Compound stability no failures no failures<br />

Granule embedment, Grade G only, max. grams 2 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

234


SBS Modified Bitumen Part 2: Test Results<br />

POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS POLYGLASS<br />

ELASTOFLEX ELASTOFLEX ELASTOFLEX ELASTOBASE ELASTOFLEX ELASTOFLEX ELASTOFLEX ELASTOFLEX<br />

S 6 GS 6 GS 6-FR V VG VG-FR SA-P<br />

POLYESTER POLYESTER POLYESTER FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS POLYESTER<br />

SMOOTH GRANULE GRANULE SMOOTH SMOOTH GRANULE GRANULE GRANULE<br />

TYPE I TYPE I TYPE I TYPE I TYPE I<br />

GRADE S GRADE S GRADE G GRADE G GRADE G<br />

TYPE I TYPE I TYPE I TYPE I TYPE I<br />

GRADE S GRADE G GRADE G GRADE G GRADE G<br />

80 120<br />

81 71<br />

140 140<br />

83 83<br />

120<br />

81<br />

140 140 140<br />

83 83 >75<br />

>40<br />

80 90 90 90<br />

2.5 3 3 3<br />

40 45 45 45<br />

2.5 3 3 3<br />

20 30 30 30<br />

3.0 3.0 3.0 3.0<br />

70 75 75 75<br />

0 0 0 0<br />

0.5 0.5 0.5 0.5<br />

no failures no failures no failures no failures<br />

2 2<br />

80 80 80 >70<br />

25 25 25 >25<br />

60 60 60 >40<br />

40 40 40 >45<br />

45 45 45 >70<br />

80 80 80


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME SIPLAST<br />

2. PRODUCT NAME PARADIENE<br />

20<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

FIBERGLASS<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B. ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

TYPE I<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80 91<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45 58<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180 70<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150 30<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210 40<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5 -5<br />

Dimensional stability, % max. 0.5 0.1<br />

Compound stability no failures no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 1<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

236


SBS Modified Bitumen Part 2: Test Results<br />

SIPLAST SIPLAST SIPLAST SIPLAST SIPLAST SIPLAST SIPLAST SIPLAST<br />

PARADIENE PARADIENE PARADIENE PARADIENE PARADIENE PARADIENE PARAFOR VERAL<br />

20 HT 20 PR 20 EG 30 30 HT 40 FR 50 LT ALUMINUM FACE<br />

FIBERGLASS COMBINATION FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS COMBINATION FIBERGLASS<br />

SMOOTH SMOOTH SMOOTH GRANULE GRANULE GRANULE GRANULE ALUMINUM<br />

TYPE II<br />

S<br />

TYPE II TYPE II TYPE I TYPE II TYPE II<br />

GRADE S GRADE S GRADE G GRADE G GRADE G<br />

TYPE II<br />

GRADE G<br />

X<br />

91<br />

55<br />

180<br />

129<br />

90<br />

91 118<br />

58 80<br />

130 130 150<br />

82 83 103<br />

150 170<br />

4 4<br />

80 80<br />

5 5<br />

120 120<br />

-5 0<br />

0.2 0.2<br />

no failures<br />

no failures<br />

1<br />

150 150 70 150 150<br />

4 4 3 5 4<br />

80 80 30 80 80<br />

5 5 3 4 5<br />

120 120 40 120 120<br />

-5 -5 -5 -5 0<br />

0.1 0.1 0.1 0.1 0.1<br />

no failures no failures no failures no failures no failures<br />

1.5 1.5 1.5<br />

X<br />

237


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME SIPLAST<br />

2. PRODUCT NAME VERAL<br />

COPPER<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

FIBERGLASS<br />

Top surface (indicate granule, smooth or foil)<br />

COPPER<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 1<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED X<br />

X<br />

238


SBS Modified Bitumen Part 2: Test Results<br />

SIPLAST SIPLAST SIPLAST SIPLAST SIPLAST SIPLAST SIPLAST SIPLAST<br />

VERAL PARADIENE PARADIENE PARADIENE PARADIENE PARADIENE PARADIENE PARADIENE<br />

STAINLESS STEEL 20 HV 20 TG 20 HT TG 20 PR TG 20 EG TG 20 HV TG 30 TG<br />

FIBERGLASS FIBERGLASS FIBERGLASS FIBERGLASS COMBINATION FIBERGLASS FIBERGLASS FIBERGLASS<br />

STAINLESS STEEL SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH GRANULE<br />

TYPE II<br />

S<br />

TYPE I TYPE I TYPE II TYPE II TYPE I TYPE I<br />

GRADE S GRADE S GRADE S GRADE S GRADE S GRADE G<br />

X<br />

110<br />

63<br />

70<br />

119 110 110 138 138<br />

150<br />

69 69 87 87<br />

99<br />

70 70 90 90 70<br />

150<br />

4<br />

80<br />

5<br />

120<br />

0<br />

0.2<br />

no failures<br />

75 75 150 150 75 75<br />

3 3 4 4 3 3<br />

30 30 80 80 30 30<br />

3 3 5 5 3 3<br />

40 40 120 120 40 40<br />

-5 -5 -5 0 0 -5<br />

0.1 0.1 0.1 0.1 0.1 0.1<br />

no failures no failures no failures no failures no failures no failures<br />

1.5<br />

X<br />

239


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME SIPLAST<br />

2. PRODUCT NAME PARADIENE<br />

20 HT TG<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

FIBERGLASS<br />

Top surface (indicate granule, smooth or foil)<br />

GRANULE<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B. ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

TYPE II<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE G<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120 150<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75 99<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 70<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180 150<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150 80<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210 120<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5 -5<br />

Dimensional stability, % max. 0.5 0.1<br />

Compound stability no failures no failures<br />

Granule embedment, Grade G only, max. grams 2 1.5<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 1<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

240


SBS Modified Bitumen Part 2: Test Results<br />

SOPRAMA SOPREMA SOPREMA SOPRAMA SOPREMA SOPREMA SOPREMA SOPREMA<br />

SOPRALENE SOPRALENE SOPRALENE SOPRALENE SOPRALENE SOPRALENE SOPRALENE SOPRALENE<br />

180 FLAM 180 180 GR FLAM 180 GR 250 FLAM 250 250 GR FLAM 250 GR<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

SMOOTH SMOOTH GRANULE GRANULE SMOOTH SMOOTH GRANULE GRANULE<br />

TYPE I TYPE I TYPE I TYPE I TYPE II TYPE II TYPE II TYPE II<br />

GRADE S GRADE S GRADE G GRADE G GRADE S GRADE S GRADE G GRADE G<br />

120 120 160 120<br />

160 160 160 160<br />

76 72 101 98<br />

99 101 101 99<br />

40 40 40 40<br />

85 85 85 85 115 115 115 115<br />

22 22 22 22 28 28 28 28<br />

65 65 65 65 100 100 100 100<br />

50 50 50 50 55 55 55 55<br />

87 87 87 87 125 125 125 125<br />

-5 -5 -5 -5 -5 -5 -5 -5<br />

0.5 0.5 0.5 0.5 0.3 0.3 0.3 0.3<br />

250 250 250 250 250 250 250 250<br />

2 2 1 1<br />

241


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME SOPREMA<br />

2. PRODUCT NAME SOPRALENE<br />

250<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

POLYESTER<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE II<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115 160<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70 99<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 150<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 35<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 130<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 53<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 160<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 -5<br />

Dimensional stability, % max. 1 0.2<br />

Compound stability no failures 250<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

242


SBS Modified Bitumen Part 2: Test Results<br />

SOPREMA SOPREMA SOPREMA SOPREMA SOPREMA SOPREMA SOPREMA SOPREMA<br />

SOPRALENE ELASTOPHENE ELASTOPHENE ELASTOPHENE SOPRALENE SOPRALENE SOPRALENE SOPRALENE<br />

350 GR FLAM GR 180 FR GR FLAM 180 FR GR 250 FR GR FLAM 250 FR GR<br />

POLYESTER GLASS GLASS GLASS POLYESTER POLYESTER POLYESTER POLYESTER<br />

GRANULE SMOOTH SMOOTH GRANULE GRANULE GRANULE GRANULES GRANULE<br />

TYPE I TYPE I TYPE I<br />

GRADE S GRADE S GRADE G<br />

TYPE II TYPE I TYPE I TYPE II TYPE II<br />

GRADE G GRADE G GRADE G GRADE G GRADE G<br />

90 120<br />

60 78<br />

40<br />

136<br />

85<br />

200 160 160 160 160<br />

125 101 101 101 117<br />

40 40 40<br />

91 91 91<br />

4 4 4<br />

41 41 41<br />

4 4 4<br />

73 73 73<br />

-5 -5 -5<br />

0 0 0<br />

250 250 250<br />

1<br />

150 85 85 115 115<br />

35 22 22 22 28<br />

130 65 65 100 100<br />

53 50 50 55 55<br />

160 87 87 125 125<br />

-5 -5 -5 -5 -5<br />

0.2 0.5 0.5 0.3 0.3<br />

250 250 250 250 250<br />

1 1 1 1 1<br />

243


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME SOPREMA<br />

2. PRODUCT NAME ELASTOPHENE<br />

FLAM GR<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

POLYESTER<br />

Top surface (indicate granule, smooth or foil)<br />

GRANULE<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B. ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

TYPE I<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE G<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120 148<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75 94<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180 91<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2 4<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150 41<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 4<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210 73<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5 -5<br />

Dimensional stability, % max. 0.5 0<br />

Compound stability no failures 250<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 1<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

244


SBS Modified Bitumen Part 2: Test Results<br />

SOPREMA SOPREMA SOPREMA SOPREMA SOPREMA SOPREMA SOPREMA SOPREMA<br />

ELASTOPHENE ELASTOHPENE ELASTOPHENE ELASTOPHENE ELASTOPHENE SOPRALAST 50 SOPRALAST SOPRALAST<br />

PS 180 180 PS FLAM FR GR FR GR TV ALU TV COPPER 50 TV INOX<br />

\<br />

GLASS POLYESTER POLYESTER GLASS GLASS GLASS FIBERGLASS GLASS<br />

SMOOTH SMOOTH SMOOTH GRANULE GRANULE ALUMINUM COPPER STAINLESS<br />

TYPE I<br />

GRADE S<br />

TYPE I<br />

GRADE S<br />

TYPE I<br />

GRADE G<br />

TYPE I<br />

GRADE G<br />

X X X<br />

120<br />

60<br />

148 136 160 140 148<br />

96 88 92 87 95<br />

40 40 40 40<br />

90 90<br />

55 52<br />

40<br />

91 91 91 175 175 175<br />

4 4 4 8 8 8<br />

41 41 41 134 134 134<br />

4 4 4 9.6 9.6 9.6<br />

73 73 73 130 130 130<br />

-5 -5 -5 -15 -15 -15<br />

0 0 0 0.1 0.1 0.1<br />

250 250 250<br />

1 1<br />

85 85<br />

22 22<br />

65 65<br />

50 50<br />

87 87<br />

-5 -5<br />

0.5 0.5<br />

250 250<br />

245


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME SOPERMA<br />

2. PRODUCT NAME SOPRAFIX (F)<br />

(H) (S) (T)<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

POLYESTER<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE I<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115 120<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70 73<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 85<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 22<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 65<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 87<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 -5<br />

Dimensional stability, % max. 1 0.5<br />

Compound stability no failures 250<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

246


SBS Modified Bitumen Part 2: Test Results<br />

SOPERMA SOPERMA SOPERMA SOPERMA SOPERMA SOPERMA SOPERMA SOPERMA<br />

SOPRALENE SOPRALENE ELASTOPHENE LASTOBOND COLPHENE GR COLPHENE COLPHENE COLPHENE<br />

250 PS 180 SP 3.5mm 3.0mm FR GR HR GR HR FR GR<br />

POLYESTER POLYESTER GLASS GLASS GLASS GLASS GLASS FIBERGLASS<br />

SMOOTH SMOOTH SMOOTH SMOOTH GRANULE GRANULE GRANULE GRANULE<br />

TYPE II<br />

GRADE S<br />

TYPE I<br />

GRADE S<br />

120 68<br />

90 38<br />

140 140 140 140<br />

83 83 85 85<br />

120 140<br />

72 86<br />

40 40<br />

91 91 91 91 175 175<br />

4 4 4 4 10 10<br />

41 41 41 41 130 130<br />

4 4 4 4 8 8<br />

73 73 73 73 130 130<br />

-5 -5 -5 -5 -5 -5<br />

0 0 0 0 0 0<br />

250<br />

1 1 1 1<br />

150 85<br />

35 22<br />

130 65<br />

53 50<br />

160 87<br />

-5 -5<br />

0.2 0.5<br />

250 250<br />

247


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME SOPREMA<br />

2. PRODUCT NAME SOPRAFIX<br />

(X)<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

POLYESTER<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE II<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115 160<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70 112<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 115<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 25<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 100<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 55<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 125<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 -5<br />

Dimensional stability, % max. 1 0.3<br />

Compound stability no failures 250<br />

Granule embedment, Grade G only, max. grams 2 1<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

248


SBS Modified Bitumen Part 2: Test Results<br />

TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO<br />

AWAPLAN AWAPLAN AWAPLAN AWAPLAN AWAPLAN AWAPLAN VERSA-FLEX VERSA-BASE<br />

PREMIUM 170 PREMIUM FR 170 FR VERSA-SMOOTH HEAT WELDING<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER FIBERGLASS<br />

GRANULE GRANULE GRANULE GRANULE SMOOTH GRANULE SMOOTH SMOOTH<br />

TYPE I<br />

GRADE G<br />

TYPE II TYPE I TYPE II TYPE I TYPE I TYPE I<br />

GRADE G GRADE G GRADE G GRADE G GRADE S GRADE S<br />

TYPE I<br />

GRADE S<br />

92<br />

160 115<br />

155 145 155 145 185<br />

98 76<br />

100 96 100 96<br />

>40 >40 >40 >40 >40 >40 >40<br />

>70<br />

>1<br />

>30<br />

>2<br />

>3<br />

>3<br />

>35<br />

100 >90 >70 >100 >70<br />

>20 >20 >20 >20 >20 >20 >20<br />

>100 >50 >100 >50 >50 >100 >100<br />

>50 >35 >50 >35 >35 >50 >50<br />

>60 >38 >60 >38 >38 >60 >60<br />

>70 >55 >70 >55 >55 >70 >70<br />


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME TEXSA, SA<br />

2. PRODUCT NAME MOFLEX<br />

FV 2.5 kg<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

FIBERGLASS<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B. ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

TYPE I<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45 51<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180 NA<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2 NA<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150 44<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2 NA<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2 NA<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210 NA<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5 0<br />

Dimensional stability, % max. 0.5 0,5<br />

Compound stability no failures no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 1<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

250


SBS Modified Bitumen Part 2: Test Results<br />

TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA<br />

MOFLEX MOFLEX MOFLEX MOFLEX MOFLEX MOFLEX MOFLEX MOFLEX FP<br />

FV 3 mm FV 3 kg FV 4 kg FP 3 mm FP 4 mm FP 3 kg FP 4 kg 3 mm GARDEN<br />

FIBERGLASS FIBERGLASS FIBERGLASS POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH SMOOTH<br />

TYPE I TYPE I TYPE I<br />

GRADE S GRADE S GRADE S<br />

TYPE I TYPE I TYPE I TYPE I TYPE I<br />

GRADE S GRADE S GRADE S GRADE S GRADE S<br />

120 104 140<br />

77 62 82<br />

120 160 104 140 120<br />

77 98 62 82 77<br />

NA NA NA<br />

NA NA NA<br />

44 44 44<br />

3 3 3<br />

NA NA NA<br />

NA NA NA<br />

NA NA NA<br />

0 0 0<br />

0,5 0,5 0,5<br />

no failures no failures no failures<br />

NA NA NA NA NA<br />

NA NA NA NA NA<br />

72 72 72 72 72<br />

35 35 35 35 35<br />

NA NA NA NA NA<br />

70 70 70 70 70<br />

0 0 0 0 0<br />

1 1 1 1 1<br />

no failures no failures no failures no failures no failures<br />

251


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME TEXSA, SA<br />

2. PRODUCT NAME MOFLEX FP 4 kg<br />

GARDEN<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

POLYESTER<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE I<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115 140<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70 82<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 NA<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 NA<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 72<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 35<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60 NA<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 0<br />

Dimensional stability, % max. 1 1<br />

Compound stability no failures no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

252


SBS Modified Bitumen Part 2: Test Results<br />

TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA<br />

MOFLEX MOFLEX MOFLEX FP MOFLEX FP MOFLEX FP-S MORTERPLAS MOFLEX FP MOFLEX<br />

FP 5 kg FP-S 5 kg 4 m MINERAL 4 kg MINERAL 5 kg MINERAL PARKING 4 kg GARDEN FP 5 kg<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

SMOOTH SMOOTH POLYESTER SMOOTH SMOOTH<br />

TYPE I TYPE I TYPE I TYPE I TYPE I TYPE II TYPE I TYPE I<br />

GRADE S GRADE S GRADE G GRADE G GRADE G GRADE S GRADE S GRADE S<br />

164 164 160 140 164<br />

60 140 164<br />

102 102 98 82 102<br />

98 82 102<br />

NA NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA NA<br />

72 89 72 72 89 100 72 72<br />

35 50 35 35 50 50 35 35<br />

NA NA NA NA NA NA NA NA<br />

70 90 70 70 90 100 70 70<br />

0 0 0 0 0 0 0 0<br />

1 1 1 1 1 1 1 1<br />

no failures no failures no failures no failures no failures no failures no failures no failures<br />

2 2 2<br />

253


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME TEXSA, SA<br />

2. PRODUCT NAME MOFLEX<br />

FP-S 5 kg<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

POLYESTER<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B.<br />

4C. ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

TYPE I<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115 164<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70 102<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100 NA<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20 NA<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70 89<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60 NA<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70 90<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 0<br />

Dimensional stability, % max. 1 1<br />

Compound stability no failures no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

254


SBS Modified Bitumen Part 2: Test Results<br />

TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA<br />

MOFLEX FP MOFLEX FP MOFLEX FP-S MORTERPLAS TEXSELF 1.5 TEXSELF M 1.5 TEXSELF HD TEXSELF PE<br />

4 mm MINERAL 4 kg MINERAL 5 kg MINERAL PARKING 2 mm<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYETHYLENE POLYETHYLENE POLYPROPYL. Woven POLYETHYLENE<br />

POLYESTER SMOOTH SMOOTH SMOOTH SMOOTH<br />

TYPE I TYPE I TYPE I TYPE II<br />

GRADE G GRADE G GRADE G GRADE S<br />

NA NA NA NA<br />

60 140 164<br />

98 82 102<br />

160 60 60 60 80<br />

98 31 31 31 41<br />

NA NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA NA<br />

72 72 89 100 28 19 80 19<br />

35 35 50 50 200 300 20 300<br />

NA NA NA NA NA NA NA NA<br />

70 70 90 100 NA NA NA NA<br />

0 0 0 0 0 0 0 0<br />

1 1 1 1 1 2,5 1 2,5<br />

no failures no failures no failures no failures 200 200 200 200<br />

2 2 2<br />

255


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME TEXSA, SA<br />

2. PRODUCT NAME TEXSELF<br />

FV 3 mm<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

FIBERGLASS<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B. ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

TYPE I<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80 120<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55 62<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180 NA<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2 NA<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150 44<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2 NA<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2 NA<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210 NA<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5 0<br />

Dimensional stability, % max. 0.5 0,5<br />

Compound stability no failures 200<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 1<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

256


SBS Modified Bitumen Part 2: Test Results<br />

TEXSA, SA TEXSA, SA TEXSA, SA TEXSA, SA TREMCO TREMCO TREMCO TREMCO<br />

TEXSELF TEXSELF FV TEXSELF TEXSELF POWERPLY POWERPLY POWERPLY POWERPLY<br />

FV 2C 4 kg MINERAL ALUMINIUM STRIP STANDARD FR HE FR PREMIUM FR PREMIUM SMOOTH<br />

FIBERGLASS FIBERGLASS ALUMINIUM FOIL FIBERGLASS POLYESTER COMBINATION COMBINATION<br />

SMOOTH GRANULE ALUMINIUM FOIL SMOOTH GRANULE GRANULE GRANULES SMOOTH<br />

TYPE II<br />

TYPE II<br />

TYPE I TYPE I TYPE I<br />

GRADE S GRADE G GRADE G<br />

X<br />

TYPE I<br />

GRADE G<br />

GRADE G<br />

S<br />

NA<br />

80 80<br />

150 150<br />

41 46.1<br />

82 93.4<br />

50<br />

120<br />

88<br />

50<br />

60<br />

31<br />

160<br />

104<br />

75<br />

60<br />

31<br />

240.9 235.2<br />

3.3 4.0<br />

276 219.9<br />

6.7 7.2<br />

379 416.7<br />

-40 -16.6<br />

0 0<br />

no failures<br />

no failures<br />

0.4<br />

NA NA 91<br />

NA NA 2.85<br />

44 44 76<br />

3 3 7.7<br />

NA<br />

NA<br />

NA<br />

NA<br />

NA NA 104<br />

0 0 -4<br />

0,5 0,5 0<br />

200 200 no failures<br />

2 1.5<br />

NA<br />

NA<br />

20<br />

3<br />

NA<br />

NA<br />

0<br />

0,2<br />

200<br />

NA 92<br />

NA 27.4<br />

28 73.6<br />

3 55.1<br />

NA<br />

NA 88.8<br />

0 -4<br />

0,2 0<br />

200 no failures<br />

1.7<br />

257


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME TREMCO<br />

2. PRODUCT NAME POWERPLY<br />

SUPREME<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

COMBINATION<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

4A.<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

TYPE III<br />

S<br />

4B.<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80 105<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250 342<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2 3.4<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250 332<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 5.5<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3 6<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280 603<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0 -38<br />

Dimensional stability, % max. 0.5 0<br />

Compound stability no failures no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6C. PHYSICAL PROPERTIES: POLYESTER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/.in. Type I: 70: Type II: 100<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning 20<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 50; Type II: 70<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min. at max. load, before and after heat conditioning Type I: 35; Type II: 50<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., before and after heat conditioning Type I: 38: Type II: 60<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 55; Type II: 70<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 1<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max. grams 2<br />

6D. PHYSICAL PROPERTIES: FOIL-SURFACED<br />

Maximum load at 0 ± 3.6 F MD and XMD, min. lbf./in. 160<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., % 3<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., lbf./in. 85<br />

Elongation at 73.4 ± 3.6 F MD and XMD, min., % 5<br />

Ultimate Elongation at 73.4 ± 3.6 F MD and XMD, min., % 25<br />

Tensile-tear strength, min., lbf. 120<br />

Low temperature flexibility, max., F 0<br />

Dimensional stability, max., % 0.2<br />

Compound stability, min., F 225<br />

7. SEE MEMBRANE APPENDIX IF CHECKED<br />

258


SBS Modified Bitumen Part 2: Test Results<br />

TREMCO U.S. INTEC U.S. INTEC U.S. INTEC U.S. INTEC U.S. INTEC U.S. INTEC W.P. HICKMAN<br />

POWERPLY BRAI SUPREME BRAI SUPREME BRAI SUPREME BRAI SUPREME BRAI SUPREME BRAI SUPREME INTEC/FLEX S<br />

SUPREME HT FR SBS POLY FR SBS POLY SBS GLASS SBS GRANULE SBS POLY SBS GLASS FR<br />

COMBINATION POLYESTER POLYESTER FIBERGLASS POLYESTER POLYESTER FIBERGLASS POLYESTER<br />

GRANULES GRANULE GRANULE SMOOTH GRANULE GRANULE GRANULE SMOOTH<br />

TYPE III<br />

GRADE G<br />

TYPE II<br />

GRADE G<br />

TYPEI<br />

TYPE I<br />

GRADE S<br />

GRADE G<br />

TYPE I TYPE I TYPE I TYPE II<br />

GRADE G GRADE G X GRADE G<br />

138<br />

100<br />

80 80<br />

95<br />

45 45<br />

65<br />

NA 40<br />

85 140<br />

145 145 130 130<br />

54 54<br />

75 90 75 75<br />

40 40 40 40 40<br />

348<br />

3.5<br />

325<br />

6.5<br />

7.6<br />

556<br />

-38<br />

0<br />

no failures<br />

0.92<br />

70 70<br />

2 1<br />

40 30<br />

2 2<br />

3 3<br />

3 3<br />

40 35<br />

0 0<br />

0.5 0.5<br />

215 no failures<br />

NA 2<br />

70 100 70 70 70<br />

20 20 20 20 20<br />

50 70 50 50 50<br />

40 50 35 35 40<br />

40 60 38 38 40<br />

70 70 55 55 70<br />

0 0 0 0 0<br />

1.0 1.0 1 1 1.0<br />

215 215 no falures no failures 215<br />

2 2 2 2 NA<br />

259


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME W.P. HICKMAN<br />

2. PRODUCT NAME PIKA PLY<br />

808<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

COMBINATION<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B. ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

TYPE III<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80 120<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45 >55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250 >250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2 >2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250 >250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 >4<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280 >280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0


SBS Modified Bitumen Part 2: Test Results<br />

W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN<br />

PIKA PLY PIKA PLY PIKA PLY PIKA PLY PIKA PLY PIKA PLY PIKA PLY PIKA PLY<br />

808 FR MS-4 SS-4 MS-3G SS-3P SS-3G SS-2 SS-3P (TG)<br />

COMBINATION POLYESTER POLYESTER FIBERGLASS POLYESTER FIBERGLASS POLYESTER POLYESTER<br />

GRANULE GRANULE SMOOTH GRANULE SMOOTH SMOOTH SMOOTH SMOOTH<br />

TYPE III TYPE I TYPE I<br />

GRADE G GRADE G GRADE S<br />

TYPE I TYPE II TYPE I TYPE I<br />

GRADE G GRADE S GRADE G GRADE S<br />

120<br />

160 120<br />

>45<br />

>85 >65<br />

40 40 40<br />

160 120 70 >54 >54<br />

>75<br />

40 40 40<br />

>250<br />

>2<br />

>250<br />

4<br />

>280<br />

70 >70<br />

>1 >1<br />

>30 >30<br />

>1 >2<br />

3<br />

>3 >3<br />

>35 >35<br />

70 >70<br />

>20 >20 >20 >20 >20<br />

>50 100 >50 >50 >50<br />

>35 >50 >35 >35 >35<br />

>38 >38 >38<br />

>55 >70 >55 >55 >55<br />


SBS Modified Bitumen Part 2: Test Results<br />

1. COMPANY NAME W.P. HICKMAN<br />

2. PRODUCT NAME PIKA PLY<br />

SS-3G (TG)<br />

3. PRODUCT DESCRIPTION<br />

Reinforcing (indicate fiberglass, polyester or combination)<br />

FIBERGLASS<br />

Top surface (indicate granule, smooth or foil)<br />

SMOOTH<br />

4. COMPLIES WITH:<br />

ASTM D 6162-00 Standard Specification for Styrene Budadiene Styrene (SBS) Modified Bitumenous<br />

4A. Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements (indicate Type I, II or<br />

III, and Grade G or S as appropriate)<br />

4B. ASTM D 6163-98 Standard Specification for Styrene Butadiene Styrene (SBS) Bitumenous Materials<br />

TYPE I<br />

Using Glass Fiber Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

GRADE S<br />

4C.<br />

4D.<br />

4E.<br />

ASTM D 6164-98 Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bitumenous Sheet<br />

Materials Using Polyester Reinforcements (indicate Type I, II, or III, and Grade G or S as appropriate)<br />

ASTM D 6298-98 Standard Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)<br />

Modified Bitumeous Sheets with a Fac<strong>to</strong>ry Applied Metal Surface (indicate "X" or NA)<br />

CGSB 37-GP-56M Standard for Membrane, Modified Bitumenous, Prefabricated and Reinforced for<br />

<strong>Roof</strong>ing (indicate Class A, B, or C, and Grade 1 or 2)<br />

5A. DIMENSIONS AND MASSES OF SHEET MATERIALS: COMBINATION OF POLYESTER AND GLASS FIBER<br />

Thickness (min., mils) Grade S Type I: 70; Type II and III: 80<br />

Thickness (min., mils) Grade G Type I: 110; Type II and III: 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 45; Type II: 50; Type III: 55<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 60; Type II: 75; Type III: 85<br />

Bot<strong>to</strong>m coating thickness (heat welding application products min., mils) 40<br />

5B. DIMENSIONS AND MASSES OF SHEET MATERIALS: GLASS FIBER REINFORCEMENTS<br />

Thickness (min., mils) Grade S 80 120<br />

Thickness (min., mils) Grade G Type I: 95: Type II: 105; Type III: 120<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S 45 >45<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 65; Type II and III: 75<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40 40<br />

5C. DIMENSIONS AND MASSES OF SHEET MATERIALS: POLYESTER REINFORCEMENTS<br />

Thickness (min., mils) Grade S Type I: 85; Type II: 115<br />

Thickness (min., mils) Grade G 130<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade S Type I: 54; Type II: 70<br />

Net mass per unit area (min., lbs./100 sq. ft.) Grade G Type I: 75; Type II: 90<br />

Bot<strong>to</strong>m coating thickness (min., mils) 40<br />

5D. DIMENSIONS AND MASSES OF SHEET MATERIAL: FOIL-SURFACED<br />

Thickness (min., mils) 134<br />

Net mass per unit area (min., lbs/100 sq. ft.) 80<br />

Back surface coating thickness (min., mils) 40<br />

6A. PHYSICAL PROPERTIES: COMBINATION OF POLYESTER AND GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 75; Type II: 125; Type III: 250<br />

Elongation at 0 ± 3.6 F, MD and XMD, % min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 75; Type II: 80; Type III: 250<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 26; Type II: 75; Type III: 3<br />

Elongation at 5% max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 9; Type II: 30; Type III: 3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 65; Type II: 90; Type III: 280<br />

Low temperature flexibility, before and after heat conditioning, F, max. 0<br />

Dimensional stability, % max. 0.5<br />

Compound stability<br />

no failures<br />

Granule embedment, Grade G only, max., grams 2<br />

6B. PHYSICAL PROPERTIES: GLASS FIBER REINFORCEMENTS<br />

Maximum load at 0 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf./in. Type I: 70: Type II: 150; Type III; 180 >70<br />

Elongation at 0 ± 3.6 F, MD and XMD, min., at max. load, before and after heat conditioning Type I: 1; Type II and III: 2 >1<br />

Maximum load at 73.4 ± 3.6 F MD and XMD, min., before and after heat conditioning, lbf/in. Type I: 30; Type II: 80; Type III: 150 >30<br />

Elongation at 73.4 ± 3.6 F MD and XMD, % min., at max. load, before and after heat conditioning Type I: 2; Type II: 4; Type III: 3 >1<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., as manufactured Type I: 3: Type II: 40: Type III: 2 >3<br />

Elongation at 5% of max. load 73.4 ± 3.6 F, MD and XMD, % min., after heat conditioning Type I: 3: Type II: 20; Type III: 2 >3<br />

Tear strength at 73.4 ± 3.6 F, lbf, min. Type I: 35; Type II: 110; Type III: 210 >35<br />

Low temperature flexibility, before and after heat conditioning, F, max. Type I and II: 0; Type III: +5


SBS Modified Bitumen Part 2: Test Results<br />

W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN W.P. HICKMAN<br />

PIKA PLY PIKA PLY PIKA PLY PERFORMANCE PERFORMANCE PERFORMANCE PREMIUM<br />

ALUMINUM MS-4 (TG) MS 4G (TG) PLY MS FR PLY MS PLY SS CAP SHEET<br />

FIBERGLASS POLYESTER FIBERGLASS POLYESTER POLYLESTER POLYESTER FIBERGLASS<br />

ALUMINUM GRANULE GRANULE GRANULE GRANULE SMOOTH GRANULE<br />

X<br />

TYPE I<br />

GRADE G<br />

TYPE I TYPE I TYPE I TYPE I<br />

GRADE G GRADE G GRADE G GRADE S<br />

TYPE I<br />

GRADE G<br />

160 136<br />

>65 >65<br />

40 40<br />

160 160 130<br />

>75 >90 >90<br />

40 40 40<br />

120<br />

>54<br />

160<br />

>80<br />

40<br />

>70 >70<br />

>1 >1<br />

>30 >30<br />

>2 >2<br />

>3 >3<br />

>3 >3<br />

>35 >35<br />

70<br />

>20 >20 >20 >20<br />

>50 >50 >50 >50<br />

>35 >35 >35 >35<br />

>38 >38 >38 >38<br />

>55 >55 >55 >55<br />


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

COMPANY NAME<br />

BITEC INC.<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

APS-4T.1 2 BETA BASE APS-4T<br />

APM-4T.1 2 BETA BASE APM-4T<br />

APM-4.5T.1 2 BETA BASE APM-4.5T<br />

SPM-4.5T.1 2 BETA BASE SPM-4.5T<br />

SPM-3.5H.1 2 BETA BASE SPM-3.5H<br />

SFM-3.5H.1 2 BETA BASE SFM-3.5H<br />

SPM-4H.1 2 BETA BASE SPM-4H<br />

SPS-3H.1 2 BETA BASE SPS-3H W/COATING<br />

APS-4T.1.15 3 BETA BASE FA-2T APS-4T W/COATING<br />

APM-4T.1.15 3 BETA BASE FA-2T APM-4T<br />

APM4.5T.1.15 3 BETA BASE FA-2T APM-4.5T<br />

SPM4.5T.1.15 3 BETA BASE PS-2H OR FS-2H SPM-4.5T<br />

SPM3.5H.1.15 3 BETA BASE PS-2H OR FS-2H SPM-3.5H<br />

SFM3.5H.1.15 3 BETA BASE PS-2H OR FS-2H SFM-3.5H<br />

SPM-4H.1.15 3 BETA BASE PS-2H OR FS-2H SPM-4H<br />

SPS-3H.1.20 3 BETA BASE SPS-3H SPS-3H GRAVEL<br />

SPS-3H.1.20 3 NONE PS-2H OR FS-2H SPS-3H SPS-3H GRAVEL<br />

APS-4T.1.20 3 BETA BASE APS-4T APS-4T W/COATING<br />

APS-4T.1.20 3 NONE FA-2T APS-4T APS-4T W/COATING<br />

APM-4T.1.20 3 BETA BASE APS-4T APM-4T<br />

APM-4T.1.20 3 NONE FA-2T APS-4T APM-4T<br />

APM4.5T.1.20 3 BETA BASE APS-4T APM-4.5T<br />

APM4.5T.1.20 3 NONE FA-2T APS-4T APM-4.5T<br />

SPM4.5T.1.20 3 BETA BASE SPS-3H SPM-4.5T<br />

SPM4.5T.1.20 3 NONE PS-2H OR FS-2H SPS-3H SPM-4.5T<br />

SPM3.5H.1.20 3 BETA BASE SPS-3H SPM-3.5H<br />

SPM3.5H.1.20 3 NONE PS-2H OR FS-2H SPS-3H SPM-3.5H<br />

SFM3.5H.1.20 3 BETA BASE SPS-3H SFM-3.5H<br />

SFM3.5H.1.20 3 NONE PS-2H OR FS-2H SPS-3H SFM-3.5H<br />

SPM-4H.1.20 3 BETA BASE SPS-3H SPM-4H<br />

SPM-4H.1.20 3 NONE PS-2H OR FS-2H SPS-3H SPM-4H<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

APS-4T.2 2 BETA BASE APS-4T<br />

APM-4T.2 2 BETA BASE APM-4T<br />

APM-4.5T.2 2 BETA BASE APM-4.5T<br />

SPM-4.5T.2 2 BETA BASE SPM-4.5T<br />

SPM-3.5H.2 2 BETA BASE SPM-3.5H<br />

SFM-3.5H.2 2 BETA BASE SFM-3.5H<br />

SPM-4H.2 2 BETA BASE SPM-4H<br />

SPS-3H.2 2 BETA BASE SPS-3H W/COATING<br />

APS-4T.2.15 3 BETA BASE FA-2T APS-4T W/COATING<br />

APM-4T.2.15 3 BETA BASE FA-2T APM-4T<br />

APM4.5T.2.15 3 BETA BASE FA-2T APM-4.5T<br />

SPM4.5T.2.15 3 BETA BASE PS-2H OR FS-2H SPM-4.5T<br />

SPM3.5H.2.15 3 BETA BASE PS-2H OR FS-2H SPM-3.5H<br />

SFM3.5H.2.15 3 BETA BASE PS-2H OR FS-2H SFM-3.5H<br />

SPM-4H.2.15 3 BETA BASE PS-2H OR FS-2H SPM-4H<br />

SPS-3H.2.20 3 BETA BASE SPS-3H SPS-3H GRAVEL<br />

SPS-3H.2.20 3 NONE PS-2H OF FS-2H SPS-3H SPS-3H GRAVEL<br />

APS-4T.2.20 3 BETA BASE APS-4T APS-4T W/COATING<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

APS-4T.2.20 3 NONE FA-2T APS-4T APS-4TW/COATING<br />

APM-4T.2.20 3 BETA BASE APS-4T APM-4T<br />

APM-4T.2.20 3 NONE FA-2T APS-4T APM-4T<br />

APM4.5T.2.20 3 BETA BASE APS-4T APM-4.5T<br />

APM4.5T.2.20 3 NONE FA-2T APS-4T APM-4.5T<br />

SPM4.5T.2.20 3 BETA BASE SPS-3H SPM-4.5T<br />

SPM4.5T.2.20 3 NONE PS-2H OR FS-2H SPS-3H SPM-4.5T<br />

SPM3.5H.2.20 3 BETA BASE SPS-3H SPM-3.5H<br />

SPM3.5H.2.20 3 NONE PS-2H OR FS-2H SPS-3H SPM-3.5H<br />

SFM3.5H.2.20 3 BETA BASE SPS-3H SFM-3.5H<br />

SFM3.5H.2.20 3 NONE PS-2H OR FS-2H SPS-3H SFM-3.5H<br />

SPM-4H.2.20 3 BETA BASE SPS-3H SPM-4H<br />

SPM-4H.2.20 3 NONE PS-2H OR FS-2H SPS-3H SPM-4H<br />

NEW / REPLACEMENT See New Replacement, Nailable and Non-nailable<br />

INSULATED<br />

264


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

COMPANY NAME<br />

RECOVER<br />

EXISTING ROOF<br />

RECOVER<br />

EXISTING ROOF<br />

INSULATION ADDED<br />

BITEC INC. (continued)<br />

See New Replacement, Nailable and Non-nailable<br />

See New Replacement, Nailable and Non-nailable<br />

COMPANY NAME<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

CELOTEX CORP.<br />

SBS-4-C-M 4 D 4601 TYPE II BASE SHEET SBS 250 CAP SHEET<br />

& 2 TYPE VI PLY SHEETS<br />

SBS-3-C-M 3 D 4601 TYPE II BASE SHEET SBS 250 CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

SBS-2-C-M 2 D 4601 TYPE II BASE SHEET SBS 250 CAP SHEET<br />

SBS-DP-4-C-M 4 D 4601 TYPE II BASE SHEET SBS DUAL PLY FR BASE SHEET SBS DUAL PLY FR CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

SBS-DP-3-C-M 3 D 4601 TYPE II BASE SHEET SBS DUAL PLY FR BASE SHEET SBS DUAL PLY FR CAP SHEET<br />

SBS-DP-2-C-M 2 SBS DUAL PLY FR BASE SHEET SBS DUAL PLY FR CAP SHEET<br />

APP-4-C-M 4 D 4601 TYPE II BASE SHEET APP 4M CAP SHEET<br />

& 2 TYPE VI PLY SHEETS<br />

APP-4-C-S 4 D 4601 TYPE II BASE SHEET APP 4S CAP SHEET<br />

& 2 TYPE VI PLY SHEETS<br />

APP-3-C-M 3 D 4601 TYPE II BASE SHEET APP 4M CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

APP-3-C-S 3 D 4601 TYPE II BASE SHEET APP 4S CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

APP-2-C-M 2 D 4601 TYPE II BASE SHEET APP 4M CAP SHEET<br />

APP-2-C-S 2 D 4601 TYPE II BASE SHEET APP 4S CAP SHEET<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

SBS-4-W-M 4 D 4601 TYPE II BASE SHEET SBS 250 CAP SHEET<br />

& 2 TYPE VI PLY SHEETS<br />

SBS-3-W-M 3 D 4601 TYPE II BASE SHEET SBS 250 CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

SBS-2-W-M 2 D 4601 TYPE II BASE SHEET SBS 250 CAP SHEET<br />

SBS-DP-4-W-M 4 D 4601 TYPE II BASE SHEET SBS DUAL PLY FR BASE SHEET SBS DUAL PLY FR CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

SBS-DP-3-W-M 3 D 4601 TYPE II BASE SHEET SBS DUAL PLY FR BASE SHEET SBS DUAL PLY FR CAP SHEET<br />

SBS-DP-2-W-M 2 SBS DUAL PLY FR BASE SHEET SBS DUAL PLY FR CAP SHEET<br />

APP-4-W-M 4 D 4601 TYPE II BASE SHEET APP 4M CAP SHEET<br />

& 2 TYPE VI PLY SHEETS<br />

APP-4-W-S 4 D 4601 TYPE II BASE SHEET APP 4S CAP SHEET<br />

& 2 TYPE VI PLY SHEETS<br />

APP-3-W-M 3 D 4601 TYPE II BASE SHEET APP 4M CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

APP-3-W-S 3 D 4601 TYPE II BASE SHEET APP 4S CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

APP-2-W-M 2 D 4601 TYPE II BASE SHEET APP 4M CAP SHEET<br />

APP-2-W-S 2 D 4601 TYPE II BASE SHEET APP 4S CAP SHEET<br />

SBS-H+3-W-M 4 HYDRO-STOP VAP. BARRIER SBS 250 CAP SHEET<br />

& 2 TYPE VI PLY SHEETS<br />

SBS-H+2-W-M 3 HYDRO-STOP VAP. BARRIER SBS 250 CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

SBS-H+2-IV-W-M 3 HYDRO-STOP VAP. BARRIER SBS 250 CAP SHEET<br />

& 1 TYPE IV PLY SHEETS<br />

SBS-DP-H+3-W-M 4 HYDRO-STOP VAP. BARRIER SBS DUAL PLY FR BASE SHEET SBS DUAL PLY FR CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

SBS-DP-H+2-W-M 3 HYDRO-STOP VAP. BARRIER SBS DUAL PLY FR BASE SHEET SBS DUAL PLY FR CAP SHEET<br />

APP-H+3-W-M 4 HYDRO-STOP VAP. BARRIER APP 4/M CAP SHEET<br />

& 2 TYPE VI PLY SHEETS<br />

APP-H+3-W-S 3 HYDRO-STOP VAP. BARRIER APP 4/S CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

APP-H+2-W-M 3 HYDRO-STOP VAP. BARRIER APP 4/M CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

APP-H+2-W-S 3 HYDRO-STOP VAP. BARRIER APP 4/S CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

APP-H+2-IV-W-M 3 HYDRO-STOP VAP. BARRIER APP 4/M CAP SHEET<br />

& 1 TYPE IV PLY SHEETS<br />

APP-H+2-IV-W-S 3 HYDRO-STOP VAP. BARRIER APP 4/S CAP SHEET<br />

& 1 TYPE IV PLY SHEETS<br />

265


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

COMPANY NAME<br />

NEW / REPLACEMENT<br />

INSULATED<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

CELOTEX CORP. (continued)<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

SBS-4-C-M 4 D 4601 TYPE II BASE SHEET SBS 250 CAP SHEET<br />

& 2 TYPE VI PLY SHEETS<br />

SBS-3-C-M 3 D 4601 TYPE II BASE SHEET SBS 250 CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

SBS-2-C-M 2 D 4601 TYPE II BASE SHEET SBS 250 CAP SHEET<br />

SBS-DP-4-C-M 4 D 4601 TYPE II BASE SHEET SBS DUAL PLY FR BASE SHEET SBS DUAL PLY FR CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

SBS-DP-3-C-M 3 D 4601 TYPE II BASE SHEET SBS DUAL PLY FR BASE SHEET SBS DUAL PLY FR CAP SHEET<br />

SBS-DP-2-C-M 2 SBS DUAL PLY FR BASE SHEET SBS DUAL PLY FR CAP SHEET<br />

APP-4-C-M 4 D 4601 TYPE II BASE SHEET APP 4M CAP SHEET<br />

& 2 TYPE VI PLY SHEETS<br />

APP-4-C-S 4 D 4601 TYPE II BASE SHEET APP 4S CAP SHEET<br />

& 2 TYPE VI PLY SHEETS<br />

APP-3-C-M 3 D 4601 TYPE II BASE SHEET APP 4M CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

APP-3-C-S 3 D 4601 TYPE II BASE SHEET APP 4S CAP SHEET<br />

& 1 TYPE VI PLY SHEETS<br />

APP-2-C-M 2 D 4601 TYPE II BASE SHEET APP 4M CAP SHEET<br />

APP-2-C-S 2 D 4601 TYPE II BASE SHEET APP 4S CAP SHEET<br />

RECOVER<br />

EXISTING ROOF<br />

INSULATION ADDED<br />

See New / Replacement Insulated<br />

Company Name<br />

NEW / REPLACEMENT<br />

CERTAINTEED ROOFING PRODUCTS GROUP<br />

NON-NAILABLE<br />

STA-C-B2 2 GLASBASE - FLINTLASTIC STA<br />

STA-C-B3 3 - FLEXIGLAS BASE FLINTLASTIC STA FLINTLASTIC STA<br />

STA-C-B4 4 - FLEXIGLAS BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC STA<br />

GTA-C-B2 2 GLASBASE - FLINTLASTIC GTA -<br />

GTA-C-B3 3 - FLEXIGLAS BASE FLINTLASTIC STA FLINTLASTIC GTA<br />

GTA-C-B4 4 - FLEXIGLAS BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC GTA<br />

GTAFR-C-B2 2 GLASBASE - FLINTLASTIC GTA-FR -<br />

GTAFR-C-B3 3 - FLEXIGLAS BASE FLINTLASTIC STA FLINTLASTIC GTA-FR<br />

GTAFR-C-B4 4 - FLEXIGLAS BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC GTA-FR<br />

GMS-C-B2 2 GLASBASE - FLINTLASTIC GMS -<br />

GMS-C-B3 3 - FLEXIGLAS BASE FLINTGLAS PLY IV FLINTLASTIC GMS<br />

GMS-C-B4 4 - FLEXIGLAS BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC GMS<br />

FRP-C-B2 2 GLASBASE - FLINTLASTIC FR-P -<br />

FRP-C-B3 3 - FLEXIGLAS BASE FLINTLASTIC PLY IV FLINTLASTIC FR-P<br />

FRP-C-B4 4 - FLEXIGLAS BASE FLINTLASTIC PLY IV (2 PLIES) FLINTLASTIC FR-P<br />

GTS-C-B2 2 GLASBASE - FLINTLASTIC GTS -<br />

GTS-C-B3 3 - FLEXIGLAS BASE FLINTGLAS PLY IV FLINTLASTIC GTS<br />

GTS-C-B4 4 - FLEXIGLAS BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC GTS<br />

FRBC-C-B2 2 - FLEXIGLAS FR BASE FLINTLASTIC FR CAP -<br />

FRBC-C-B3 3 - FLEXIGLAS FR BASE FLEXIGLAS FR BASE FLINTLASTIC FR CAP<br />

FRBC-C-B4 4 - FLEXIGLAS FR BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC FR CAP<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

STA-N-B2 2 GLASBASE - FLINTLASTIC STA<br />

STA-N-B3 3 - FLEXIGLAS BASE FLINTLASTIC STA FLINTLASTIC STA<br />

STA-N-B4 4 - FLEXIGLAS BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC STA<br />

GTA-N-B2 2 GLASBASE - FLINTLASTIC GTA -<br />

GTA-N-B3 3 - FLEXIGLAS BASE FLINTLASTIC STA FLINTLASTIC GTA<br />

GTA-N-B4 4 - FLEXIGLAS BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC GTA<br />

NEW / REPLACEMENT<br />

NAILABLE (contd)<br />

GTAFR-N-B2 2 GLASBASE - FLINTLASTIC GTA-FR -<br />

GTAFR-N-B3 3 - FLEXIGLAS BASE FLINTLASTIC STA FLINTLASTIC GTA-FR<br />

GTAFR-N-B4 4 - FLEXIGLAS BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC GTA-FR<br />

GMS-N-B2 2 GLASBASE - FLINTLASTIC GMS -<br />

GMS-N-B3 3 - FLEXIGLAS BASE FLINTGLAS PLY IV FLINTLASTIC GMS<br />

GMS-N-B4 4 - FLEXIGLAS BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC GMS<br />

FRP-N-B2 2 GLASBASE - FLINTLASTIC FR-P -<br />

266


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

CERTAINTEED ROOFING PRODUCTS GROUP (continued)<br />

FRP-N-B3 3 - FLEXIGLAS BASE FLINTLASTIC PLY IV FLINTLASTIC FR-P<br />

FRP-N-B4 4 - FLEXIGLAS BASE FLINTLASTIC PLY IV (2 PLIES) FLINTLASTIC FR-P<br />

GTS-N-B2 2 GLASBASE - FLINTLASTIC GTS -<br />

GTS-N-B3 3 - FLEXIGLAS BASE FLINTGLAS PLY IV FLINTLASTIC GTS<br />

GTS-N-B4 4 - FLEXIGLAS BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC GTS<br />

FRBC-N-B3 3 GLASBASE - FLEXIGLAS FR BASE FLINTLASTIC FR CAP<br />

FRBC-N-B4 4 - FLEXIGLAS FR BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC FR CAP<br />

Company Name<br />

NEW / REPLACEMENT<br />

See description of the following specs under New / Replacement Nailable and Non-Nailable<br />

INSULATED<br />

STA-N-B2/IN GMS-C-B2/IC<br />

STA-N-B3/IN GMS-C-B3/IC<br />

STA-N-B4/IN GMS-C-B4/IC<br />

STA-C-B2/IC FRP-N-B2/IN<br />

STA-C-B3/IC FRP-N-B3/IN<br />

STA-C-B4/IC FRP-N-B4/IN<br />

GTA-N-B2/IN FRP-C-B2/IC<br />

GTA-N-B3/IN FRP-C-B3/IC<br />

GTA-N-B4/IN FRP-C-B4/IC<br />

GTA-C-B2/IC GTS-N-B2/IN & (All New/Replacement Specs /IS)<br />

GTA-C-B3/IC GTS-N-B3/IN<br />

GTA-C-B4/IC GTS-N-B4/IN<br />

GTAFR-N-B2/IN GTS-C-B2/IC<br />

GTAFR-N-B3/IN GTS-C-B3/IC<br />

GTAFR-N-B4/IN GTS-C-B4/IC<br />

GTAFR-C-B2/IC FRBC-N-B3/IN<br />

GTAFR-C-B3/IC FRBC-N-B4/IN<br />

GTAFR-C-B4/IC FRBC-C-B2/IN<br />

GMS-N-B2/IN FRBC-C-B3/IN<br />

GMS-N-B3/IN FRBC-C-B4/IN<br />

GMS-N-B4/IN<br />

RECOVER See description of the following specs under New / Replacement Nailable and Non-Nailable<br />

EXISTING ROOF<br />

STA-N-B2/RN GMS-N-B2/RN FRBC-N-B3/RN<br />

STA-N-B3/RN GMS-N-B3/RN FRBC-N-B4/RN<br />

STA-N-B4/RN GMS-N-B4/RN FRBC-C-B2/RC<br />

STA-C-B2/RC GMS-C-B2/RC FRBC-C-B3/RC<br />

STA-C-B3/RC GMS-C-B3/RC FRBC-C-B4/RC<br />

STA-C-B4/RC GMS-C-B4/RC<br />

GTA-N-B2/RN FRP-N-B2/RN<br />

GTA-N-B3/RN FRP-N-B3/RN<br />

GTA-N-B4/RN FRP-N-B4/RN<br />

GTA-C-B2/RC FRP-C-B2/RC<br />

GTA-C-B3/RC FRP-C-B3/RC<br />

GTA-C-B4/RC FRP-C-B4/RC<br />

GTAFR-N-B2/RN GTS-N-B2/RN<br />

GTAFR-N-B3/RN GTS-N-B3/RN<br />

GTAFR-N-B4/RN GTS-N-B4/RN<br />

GTAFR-C-B2/RC GTS-C-B2/RC<br />

GTAFR-C-B3/RC GTS-C-B3/RC<br />

GTAFR-C-B4/RC GTS-C-B4/RC<br />

RECOVER<br />

EXISTING ROOF<br />

(All New/Replacement Specs /R)<br />

INSULATION ADDED<br />

Company Name<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

DANOSA CARIBBEAN, INC.<br />

1-RC 2 GLASDAN R-36 GLASDAN AL-80-3<br />

3-RC 2 ESTERDAN R-36 ESTERDAN RM<br />

6-RC 1 GLASDAN AL-80<br />

7-RC 1 ESTERDAN RM-5<br />

8-RC 2 GLASDAN R-36 ESTERDAN RM<br />

9-RC 2 GLASDAN R-36 GLASDAN RM<br />

9-RC 2 BASEDAN IV GLASDAN RM<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

1-LW 3 BASEDAN II ESTERDAN R-36 ESTERDAN RM<br />

3-LW 3 BASEDAN II GLASDAN R-36 ESTERDAN RM<br />

1-WP 3 BASEDAN II ESTERDAN R-35 ESTERDAN RM<br />

2-WP 2 BASEDAN II ESTERDAN RM-5<br />

267


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

DANOSA CARIBBEAN, INC. (continued)<br />

3-WP 3 BASEDAN II GLASDAN R-36 ESTERDAN RM<br />

5-ID (H/A) 3 BASEDAN II ESTERDAN RM<br />

NEW / REPLACEMENT<br />

INSULATED<br />

1-ID 3 BASEDAN II ESTERDAN R-35 ESTERDAN RM<br />

4-ID 3 BASEDAN II GLASDAN R-36 ESTERDAN RM<br />

RECOVER<br />

EXISTING ROOF<br />

1-ID 3 BASEDAN II ESTERDAN R-36 ESTERDAN RM<br />

4-ID 3 BASEDAN II GLASDAN R-36 ESTERDAN RM<br />

RECOVER<br />

EXISTING ROOF<br />

INSULATION ADDED<br />

1-ID 3 BASEDAN II ESTERDAN R-36 ESTERDAN RM<br />

4-ID 3 BASEDAN II GLASDAN R-36 ESTERDAN RM<br />

Company Name<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

DIBITEN<br />

403 1 NONE POLY/4<br />

453 1 NONE POLY/4.5 GRANULAR<br />

403-2 2 NONE POLY/4 POLY/4<br />

453-2 2 NONE POLY/4 POLY/4.5 GRANULAR<br />

503 2 NONE POLY/4<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

401 2 APPROVED POLY/4<br />

451 2 APPROVED POLY/4.5 GRANULAR<br />

401-2 3 APPROVED POLY/4 POLY/4<br />

451-2 3 APPROVED POLY/4 POLY/4.5 GRANULAR<br />

501 2 APPROVED POLY/5<br />

NEW / REPLACEMENT<br />

INSULATED<br />

402 2 FIBERGLASS POLY/4<br />

152 2 FIBERGLASS POLY/4.5 GRANULAR<br />

404 2 FIBERGLASS POLY/4<br />

454 2 FIBERGLASS POLY/4.5 GRANULAR<br />

402-2 3 FIBERGLASS POLY/4 POLY/4<br />

452-2 3 FIBERGLASS POLY/4 POLY/4.5 GRANULAR<br />

404-2 3 FIBERGLASS POLY/4 POLY/4<br />

454-2 3 FIBERGLASS POLY/4 POLY/4.5 GRANULAR<br />

502 2 FIBERGLASS POLY/5<br />

504 2 FIBERGLASS POLY/5<br />

RECOVER<br />

EXISTING ROOF<br />

R 405 2 FIBERGLASS POLY/4<br />

R 455 2 FIBERGLASS POLY/4.5 GRANULAR<br />

R 406 2 FIBERGLASS POLY/4<br />

R 456 2 FIBERGLASS POLY/4.5 GRANULAR<br />

R 505 2 FIBERGLASS POLY/5<br />

R 506 2 FIBERGLASS POLY/5<br />

RECOVER<br />

EXISTING ROOF<br />

INSULATION ADDED<br />

402 2 FIBERGLASS POLYL/4<br />

452 2 FIBERGLASS POLY/4.5 GRANULAR<br />

404 2 FIBERGLASS POLY/4<br />

454 2 FIBERGLASS POLY/4.5 GRANULAR<br />

402-2 3 FIBERGLASS POLY/4 POLY/4<br />

452-2 3 FIBERGLASS POLY/4 POLY/4.5 GRANULAR<br />

404-2 3 FIBERGLASS POLY/4 POLY/4<br />

454-2 3 FIBERGLASS POLY/4 POLY/4.5 GRANULAR<br />

502 2 FIBERGLASS POLY/5<br />

504 2 FIBERGLASS POLY/5<br />

268


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

ECOLOGY ROOF SYSTEMS<br />

2000-2-CON-M 2 ERS 401 ANY ERS 500 SERIES ANY ERS 500,600 OR 700 SERIES<br />

2000-2-CON-C 2 ERS 401 ANY ERS 500 SERIES ANY ERS 500,600 OR 700 SERIES<br />

2000-2-CON-G 2 ERS 401 ANY ERS 500 SERIES ANY ERS 500,600 OR 700 SERIES<br />

2000-3-CON-M 3 ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2000-3-C0N-C 3 ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2000-3-CON0G 3 ERS 401 ANY ERS 500 SERIES ANY ERS 500 S0 ANY ERS 500, 600 OR 700 SERIES<br />

2002-2-CON-M ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2002-2-CON- C ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2002-2-CON-G ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

3000-2-CON-M ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES<br />

3000-2-CON-C ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES<br />

3000-2-CON-G ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES<br />

3000-3-CON-M 3 ERS 401 ANY ERS 400, 500 SERIES ANY ERS 400, 500 SERIES<br />

3000-3-CON-C 3 ERS 401 ANY ERS 400, 500 SERIES ANY ERS 400, 500 SERIES<br />

3000-3-CON-G 3 ERS 401 ANY ERS 400, 500 SERIES ANY ERS 400, 500 SERIES<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

2000-2-ND-M 2 ERS 401 ANY ERS 300 SERIES ANY ERS 500,600 OR 700 SERIES<br />

2000-2-ND-C 2 ERS 401 ANY ERS 300 SERIES ANY ERS 500, 600 0R 700 SERIES<br />

2000-2-ND-G 2 ERS 401 ANY ERS 300 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2000-2-ND-M 2 ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600 0R 700 SERIES<br />

2000-3-ND-C ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600 0R 700 SERIES<br />

2000-3-ND-G ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600, OR 700 SERIES<br />

2002-2-ND-M ERS 401 ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2002-2-ND-C ERS 401 ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2002-2-ND-G 2 ANY ERS 500 SERIES ANY 505, 507<br />

2002-2-ND-M 3 ANY ERS 500 SERIES ANY ERS 600 SERIES<br />

3000-2-ND-C 3 ANY ERS 500 SERIES ANY ERS 600 SERIES<br />

3000-3-ND-G 3 ANY ERS 500 SERIES ANY ERS 600 SERIES<br />

3000-3-ND-M 3 ERS 400, 401 ANY ERS 500, 600 SERIES ANY ERS 500, 600 SERIES ANY ERS 600, 700 SERIES<br />

3000-3-ND-C 3 ERS 400, 401 ANY ERS 500, 600 SERIES ANY ERS 500, 600 SERIES ANY ERS 600, 700 SERIES<br />

3000-3-ND-G 3 ERS 400, 401 ANY ERS 500, 600 SERIES ANY ERS 500, 600 SERIES ANY ERS 600, 700 SERIES<br />

NEW / REPLACEMENT<br />

INSULATED<br />

2000-2-IN-M 2 ERS 400 ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2000-2-IN-C 2 ERS 400 ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2000-2-IN-G 2 ERS 400 ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2000-3-IN-M 3 ERS 400 ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2000-3-IN-C 3 ERS 400 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2000-3-IN-G 3 ERS 400 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2002-2-IN-M ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2002-2-IN-C ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2002-2-IN-G ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

3000-2-IN-M ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

3000-2-IN-C ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

3000-2-IN-G ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

3000-3-IN-M 3 ERS 400, 400-6, 401 ANY ERS 500, 600 SERIES ANY ERS 500, 600 SERIES ANY ERS 600, 700 SERIES<br />

3000-3-IN-C 3 ERS 400, 400-6, 401 ANY ERS 500, 600 SERIES ANY ERS 500, 600 SERIES ANY ERS 600, 700 SERIES<br />

3000-3-IN-G 3 ERS 400, 400-6, 401 ANY ERS 500, 600 SERIES ANY ERS 500, 600 SERIES ANY ERS 600, 700 SERIES<br />

RECOVER<br />

EXISTING ROOF<br />

RECOVER<br />

EXISTING ROOF<br />

INSULATION ADDED<br />

2000-2-IN-M 2 ERS 401 ANY ERS 500 SERIES ANY ERS 500, 600 0R 700 SERIES<br />

2000-2-IN-C 2 ERS 401 ANY ERS 500 SERIES ANY ERS 500, 600 0R 700 SERIES<br />

2000-2-IN-G 2 ERS 401 ANY ERS 500 SERIES ANY ERS 500, 600 0R 700 SERIES<br />

2000-3-IN-M 3 ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2000-3-IN-C 3 ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2000-3-IN-G 3 ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

2002-2-IN-M ANY ERS 500 SERIES ANY ERS 500, 600 0R 700 SERIES<br />

2002-2-IN-C ANY ERS 500 SERIES ANY ERS 500, 600 0R 700 SERIES<br />

2002-2=IN-G ANY ERS 500 SERIES ANY ERS 500, 600 0R 700 SERIES<br />

3000-2-IN-M ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES ANY ERS 500, 600 OR 700 SERIES<br />

300O-2-IN-C ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES<br />

3000-2-IN-G ERS 401 ANY ERS 500 SERIES ANY ERS 500 SERIES<br />

3000-3-IN-M 3 ERS 4OO, 400-6 , 401 ANY ERS 500, 600 SERIES ANY ERS 500, 600 SERIES ANY ERS 600, 700 SERIES<br />

3000-3-IN-C 3 ERS 400, 400-6, 401 ANY ERS 500, 600 SERIES ANY ERS 500, 600 SERIES ANY ERS 600, 700 SERIES<br />

3000-3-IN-G 3 ERS 400, 400-6, 401 ANY ERS 500, 600 SERIES ANY ERS 500, 600 SERIES ANY ERS 600, 700 SERIES<br />

269


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

Company Name<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

FIRESTONE BUILDING PRODUCTS<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

C-PM-16-C 2 MB BASE SHEET APP160 COATING<br />

C-PM-17-C 2 MB BASE SHEET APP170 COATING<br />

C-PM-18-M 2 MB BASE SHEET APP180<br />

C-PM-18FR-M 2 MB BASE SHEET APP180FR<br />

C-PM16-18-M 3 MB BASE SHEET APP160 APP180<br />

C-PM16-18FR-M 3 MB BASE SHEET APP160 APP180FR<br />

C-PM-30-M 2 MB BASE SHEET SBS<br />

C-PM-31-M 2 MB BASE SHEET SBS FR<br />

C-PM-32-G 2 MB BASE SHEET SBS SMOOTH FLOOD COAT<br />

C-PM-33-M 2 MB BASE SHEET SBS PREMIUM<br />

C-PS-36-M 2 MB BASE SHEET SBS PREMIUM FR<br />

C-PS-40-M 2 MB BASE SHEET SBS TORCH<br />

C-P32-33-M 2 - SBS SMOOTH SBS PREMIUM<br />

C-P32-36-M 2 - SBS SMOOTH SBS PREMIUM FR<br />

C-P-46-40-M 2 - SBS GLASS TORCH BASE SBS TORCH<br />

C-P-46-41-M 2 - SBS GLASS TORCH BASE SBS FR TORCH<br />

C-P-45-40-M 2 - SBS GLASS TORCH BASE SBS TORCH<br />

C-P-45-41-M 2 - SBS POLY TORCH BASE SBS FR TORCH<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

L-M-16-C 2 MB BASE SHEET APP160 COATING<br />

L-M-17-C 2 MB BASE SHEET APP170 COATING<br />

L-M-18-M 2 MB BASE SHEET APP180<br />

L-M-18FR-M 2 MB BASE SHEET APP180FR<br />

L-M16-18-M 3 MB BASE SHEET APP160 APP180<br />

L-M16-18FR-M 3 MB BASE SHEET APP160 APP180FR<br />

L-M30-M 2 MB BASE SHEET SBS<br />

L-M31-M 2 MB BASE SHEET SBS FR<br />

L-M32-G 2 MB BASE SHEET SBS SMOOTH FLOOD COAT<br />

L-M33-M 2 MB BASE SHEET SBS PREMIUM<br />

L-M36-M 2 MB BASE SHEET SBS PREMIUM FR<br />

L-M32-33-M 3 MB BASE SHEET SBS SMOOTH SBS PREMIUM<br />

L-M32-36-M 3 MB BASE SHEET SBS SMOOTH SBS PREMIUM FR<br />

W-M16-C 2 MB BASE SHEET APP160 COATING<br />

W-M17-C 2 MB BASE SHEET APP170 COATING<br />

W-M-18-M 2 MB BASE SHEET APP180<br />

W-M-18FR-M 2 MB BASE SHEET APP180FR<br />

W-M16-18-M 3 MB BASE SHEET APP160 APP180<br />

W-M16-18FR-M 3 MB BASE SHEET APP160 APP180FR<br />

W-M30-M 2 MB BASE SHEET SBS<br />

W-M31-M 2 MB BASE SHEET SBS FR<br />

W-M32-G 2 MB BASE SHEET SBS SMOOTH FL00D COAT<br />

W-M33-M 2 MB BASE SHEET SBS PREMIUM<br />

W-M36-M 2 MB BASE SHEET SBS PREMIUM FR<br />

W-M40-M 2 MB BASE SHEET SBS TORCH<br />

W-M32-33-M 3 MB BASE SHEET SBS SMOOTH SBS PREMIUM<br />

W-M32-36-M 3 MB BASE SHEET SBS SMOOTH SBS PREMIUM FR<br />

W-M-46-40-M 3 MB BASE SHEET SBS GLASS TORCH BASE SBS TORCH<br />

W-M-46-41-M 3 MB BASE SHEET SBS GLASS TORCH BASE SBS FR TORCH<br />

W-M-45-40-M 3 MB BASE SHEET SBS POLY TORCH BASE SBS TORCH<br />

W-M-45-41-M 3 MB BASE SHEET SBS POLY TORCH BASEQ SBS FR TORCH<br />

NEW / REPLACEMENT<br />

INSULATED<br />

I-M16-C 2 MB BASE SHEET APP160 COATING<br />

I-M17-C 2 MB BASE SHEET APP170 COATING<br />

I-M18-M 2 MB BASE SHEET APP180<br />

I-M18FR-M 2 MB BASE SHEET APP180 FR<br />

I-M16-18-M 3 MB BASE SHEET APP160 APP180<br />

270


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

FIRESTONE BUILDING PRODUCTS (continued)<br />

I-M16-18FR-M 3 MB BASE SHEET APP160 APP180 FR<br />

I-M30-M 2 MB BASE SHEET SBS<br />

I-M31-M 2 MB BASE SHEET SBS FR<br />

I-M32-G 2 MB BASE SHEET SBS SMOOTH FL00D COAT<br />

I-M33-M 2 MB BASE SHEET SBS PREMIUM<br />

I-M36-M 2 MB BASE SHEET SBS PREMIUM FR<br />

I-M41-M 2 MB BASE SHEET SBS TORCH<br />

I-32-33-M 2 SBS SMOOTH SBS PREMIUM<br />

I-32-36-M 2 SBS SMOOTH SBS PREMIUM FR<br />

I-46-41-M 2 SBS GLASS TORCH BASE SBS FR TORCH<br />

I-45-41-M 2 SBS POLY TORCH BASE SBS FR TORCH<br />

RECOVER<br />

EXISTING ROOF<br />

E-M16-C 2 MB BASE SHEET APP160 COATING<br />

E-M17-C 2 MB BASE SHEET APP170 COATING<br />

E-M18-M 2 MB BASE SHEET APP180<br />

E-M18FR-M 2 MB BASE SHEET APP180 FR<br />

E-M30-M 2 MB BASE SHEET SBS<br />

E-M31-M 2 MB BASE SHEET SBS FR<br />

E-M32-G 2 MB BASE SHEET SBS SMOOTH FL00D COAT<br />

E-M33-M 2 MB BASE SHEET SBS PREMIUM<br />

E-M36-M 2 MB BASE SHEET SBS PREMIUM FR<br />

E-M40-M 2 MB BASE SHEET SBS TORCH<br />

RECOVER<br />

EXISTING ROOF<br />

INSULATION ADDED<br />

I-M16-C 2 MB BASE SHEET APP160 COATING<br />

I-M17-C 2 MB BASE SHEET APP170 COATING<br />

I-M18-M 2 MB BASE SHEET APP180<br />

I-M18FR-M 2 MB BASE SHEET APP180 FR<br />

I-M30-M 2 MB BASE SHEET SBS<br />

I-M31-M 2 MB BASE SHEET SBS FR<br />

I-M32-G 2 MB BASE SHEET SBS SMOOTH FL00D COAT<br />

I-M33-M 2 MB BASE SHEET SBS PREMIUM<br />

I-M36-M 2 MB BASE SHEET SBS PREMIUM FR<br />

I-M40-M 2 MB BASE SHEET SBS TORCH<br />

COMPANY<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

GAF MATERIALS CORPORATION<br />

NN-0-1-TS 1 NONE RUBEROID TORCH (SMOOTH)<br />

NN-1-1-TG 2 GAFGLAS 75 BASE SHEET RUBEROID TORCH (GRANULE)<br />

NN-1-1-MG 2 GAFGLAS 75 BASE SHEET RUBEROID MOP (GRANULE)<br />

NN-1-1-MGFR 2 GAFGLAS 75 BASE SHEET RUBEROID 170 FR<br />

NN-1-1-MSG 2 GAFGLAS 75 BASE SHEET RUBEROID MOP SMOOTH (GRAVEL)<br />

NN-1-1-TS 2 GAFGLAS 75 BASE SHEET RUBEROID TORCH (SMOOTH)<br />

NN-01-TG 1 NONE RUBEROID TORCH GRANULE<br />

NN-01-TSC 1 NONE RUBEROID TORCH<br />

NN-1-1-TSC 2 GAFGLAS 75 BASE SHEET RUBEROID TORCH<br />

NN-1-2-20/30 3 GAFGLAS 75 BASE SHEET RUBEROID 20 RUBEROID 30<br />

NN-1-2-20/30 FR 3 GAFGLAS 75 BASE SHEET RUBEROID 20 RUBEROID 30 FR<br />

MN-0-2-TS (PD) 2 RUBEROID TORCH (SMOOTH) RUBEROID TORCH (SMOOTH)<br />

MN-0-3-TS (PD0 3 RUBEROID TORCH (SMOOTH) RUBEROID TORCH (SMOOTH) RUBEROID TORCH (SMOOTH<br />

MN-0-2-MS (PD) 2 RUBEROID MOP (SMOOTH) RUBEROID MOP (SMOOTH<br />

MN-0-3-MS (PD) 3 RUBEROID MOP (SMOOTH) RUBEROID MOP (SMOOTH RUBEROID TORCH (SMOOTH<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

N-1-1-TG 2 GAFGLAS 75 BASE SHEET RUBEROID TORCH (GRANULE)<br />

N-1-1-MG 2 GAFGLAS 75 BASE SHEET RUBEROID MOP (GRANULE)<br />

N-1-1-TS 2 GAFGLAS 75 BASE SHEET RUBEROID TORCH (SMOOTH)<br />

N-1-1-TSC 2 GAFGLAS 75 BASE SHEET RUBERIOD TORCH (SMOOTH)<br />

271


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

COMPANY<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

GAF MATERIALS CORPORATION (continued)<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

NEW /<br />

NAILABLE<br />

N-1-1-M170FR 2 GAFGLAS 75 BASE SHEET RUBEROID MOP 170 FR<br />

N-1-1-MG 3 GAFGLAS 75 BASE SHEET RUBERIOD MOP (GRANULE)<br />

N-1-2-MGP 3 GAFGLAS 75 BASE SHEET RUBEROID MOP (SMOOTH) RUBEROID MOP PLUS<br />

N-1-2-MGPFR 3 GAFGLAS 75 BASE SHEET RUBEROID MOP (SMOOTH) RUBEROID MOP FR<br />

N-1-2-TGP 3 STRATAVENT RUBEROID TORCH SMOOTH RUBEROID TORCH PLUS<br />

N-1-2-TGPFR 3 STRATAVENT RUBEROID TORCH SMOOTH RUBEROID TORCH FR<br />

N-2-1-MGP 3 GAFGLAS 75 BASE SHEET RUBEROID MOP PLUS<br />

AND 1 PLY 4 OR PLY 6<br />

N-2-1-MGPFR 3 GAFGLAS STRATAVENT RUBEROID MOP FR<br />

AND 1 PLY 4 OR PLY 6<br />

N-2-1-TGP 3 GAFGLAS STRATAVENT RUBEROID TORCH PLUS<br />

AND GAFGLAS PLY 6<br />

N-2-1-TGPFR 3 GAFGLAS STRATAVENT RUBEROID TORCH FR<br />

AND GAFGLAS PLY 6<br />

N-2-(20/P6)-1-M6P 3 GAFGLAS PLY 6 RUBEROID 20 RUBEROID MOP PLUS<br />

N-2-(20/P6)-1-M6PFR 3 GAFGLAS PLY 6 RUBEROID 20 RUBEROID MOP FR<br />

N-3-1-MGP 4 GAFGLAS STRATAVENT RUBEROID MOP PLUS<br />

AND 2 PLY 4 OR PLY 6<br />

N-3-1-MGPFR 4 GAFGLAS STRATAVENT RUBEROID MOP FR<br />

AND 2 PLY 4 OR PLY 6<br />

N-3-1-TGP 4 GAFGLAS STRATAVENT RUBEROID TORCH PLUS<br />

AND 2 GAFGLAS PLY 6<br />

N-3-1-TGPFR 4 GAFGLAS STRATAVENT RUBEROID TORCH FR<br />

AND 2 GAFGLAS PLY 6<br />

N-1-2-20/30 3 GAFGLAS 75 BASE SHEET RUBEROID 20 RUBEROID 30<br />

OR 1 PLY 4 OR PLY 6<br />

N-1-2-20/30 FR 3 GAFGLAS 75 BASE SHEET RUBEROID 20 RUBEROID 30 FR<br />

OR 1 PLY 4 OR PLY 6<br />

N-1-2-20/MG 3 GAFGLAS STRATAVENT RUBEROID 20 RUBEROID MOP (GRANULE)<br />

BASE SHEET<br />

N-1-2-20/MGP 3 GAFGLAS STRATAVENT RUBEROID 20 RUBEROID MOP PLUS<br />

BASE SHEET<br />

N-1-2-20/MGPFR 3 GAFGLAS STRATAVENT RUBEROID 20 RUBEROID MOP FR<br />

BASE SHEET<br />

NEW / REPLACEMENT<br />

INSULATED<br />

I-1-1-TG 2 GAFGLAS 75 BASE SHEET RUBEROID TORCH (GRANULE)<br />

I-2-1-TG 3 2 GAFGLAS PLY 4 OR 6 RUBEROID TORCH (GRANULE)<br />

I-1-2-TGPFR 3 GAFGLAS 75 BASE SHEET RUBEROID TORCH RUBEROID TORCH FR<br />

I-2-1-TGPFR 3 GAFGLAS 75 BASE SHEET RUBEROID TORCH FR<br />

AND 1 PLY 4 OR PLY 6<br />

I-2-1-MGPFR 3 GAFGLAS 75 BASE SHEET RUBEROID MOP FR<br />

AND 1 PLY 4 OR PLY 6<br />

I-0-2-20-MGPFR 2 NONE RUBEROID 20 (SMOOTH) RUBERIOD MOP FR<br />

I-3-1-TGPFR 4 3 GAFGLAS PLY 4 OR 6 RUBEROID TORCH FR<br />

I-3-1-MGPFR 4 3 GAFGLAS PLY 4 OR 6 RUBEROID MOP FR<br />

I-1-2-20-MGP 3 GAFGLAS 75 BASE SHEET RUBEROID MOP 20 RUBEROID MOP PLUS<br />

I-1-2-MGPFR 3 GAFGLAS 75 BASE SHEET RUBEROID MOP (SMOOTH) RUBEROID MOP FR<br />

I-1-1-TSC 2 GAFGLAS 75 BASE SHEET RUBEROID TORCH (SMOOTH)<br />

I-2-1-TGP 3 2 GAFGLAS PLY 6 RUBEROID TORCH PLUS<br />

I-1-2-TGP 3 GAFGLAS 75 BASE SHEET RUBEROID TORCH PLUS<br />

I-0-2-MGP 2 NONE RUBEROID MOP 20 RUBEROID MOP PLUS<br />

I-1-2-20/30 3 GAFGLAS 75 BASE SHEET RUBEROID 20 RUBEROID 30<br />

I-1-2-20/30 FR 3 GAFGLAS 75 BASE SHEET RUBEROID 20 RUBEROID 30 FR<br />

I-0-2-20/30 2 NONE RUBEROID 20 RUBEROID 30<br />

I-0-2-20/30 FR 2 NONE RUBEROID 20 RUBEROID 30 FR<br />

I-1-2-20/MG 3 GAFGLAS 75 BASE SHEET RUBEROID 20 RUBEROID MOP (GRANULE)<br />

I-1-2-20/MGP 3 GAFGLAS 75 BASE SHEET RUBEROID 20 RUBEROID MOP PLUS<br />

I-1-2-20/MGPFR 3 GAFGLAS 75 BASE SHEET RUBEROID 20 RUBEROID MOP FR<br />

I-1-1-MGFR 2 GAFGLAS BASE SHEET RUBEROID MOP 170FR<br />

I-1-1-MGP 2 GAFGLAS BASE SHEET RUBEROID MOP PLUS<br />

I-2-1-MG 3 GAFGLAS PLY 4 OR 6 RUBEROID MOP (GRANULE)<br />

I-2-1-MGFR 3 GAFGLAS PLY 4 OR 6 RUBEROID MOP 170FR<br />

I-O-2-20/MG 2 NONE RUBEROID 20 RUBEROID MOP (GRANULE)<br />

I-O-2-20/MGP 2 NONE RUBEROID 20 RUBEROID MOP PLUS<br />

I-O-2-20/MGFR 2 NONE RUBEROID 20 RUBEROID MOP FR<br />

1-0-2-TS (PD) 2 RUBEROID TORCH (SMOOTH) RUBEROID TORCH (SMOOTH)<br />

1-0-3-TS (PD) 3 RUBEROID TORCH (SMOOTH) RUBEROID TORCH (SMOOTH) RUBEROID TORCH (SMOOTH)<br />

1-0-2-MS (PD) 2 RUBEROID TORCH (SMOOTH) RUBEROID MOP (SMOOTH)<br />

1-0-3-MS (PD) 3 RUBEROID MOP (SMOOTH) RUBEROID MOP (SMOOTH) RUBEROID MOP (SMOOTH)<br />

272


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

COMPANY<br />

GAF MATERIALS CORPORATION (continued)<br />

RECOVER<br />

EXISTING ROOF<br />

R-1-1-TG 2 GAFGLAS 75 BASE SHEET RUBEROID TORCH<br />

R-1-1-MG 2 GAFGLAS 75 BASE SHEET RUBEROID MOP<br />

R-1-1-MSG 2 GAFGLAS STRATAVENT RUBEROID MOP SMOOTH (GRAVEL)<br />

R-1-1-TS 2 GAFGLAS 75 BASE SHEET RUBEROID TORCH<br />

R11M6FR 2 GAFGLAS STRATAVENT RUBEROID MOP 170FR<br />

R-0-1-TG 1 NONE RUBEROID TORCH<br />

R-0-1-TS 1 NONE RUBEROID TORCH<br />

R-1-1-TSC 2 GAFGLAS 75 BASE SHEET RUBEROID TORCH<br />

Company Name<br />

New / Replacement<br />

HENRY COMPANY<br />

NON-NAILABLE<br />

CDU/PMR 2004 2 G100s/s[p/s] OR G100gM[MFR] OR NP180gM[MFR] or<br />

NP180s/s[p/s][p/p] NP250gM[MFR] or NP250gT4[TFR]<br />

CDU 2004 2 COATED GLASS BASE NP180gM[MFR] or NP180gT[TFR] or<br />

NP250gM[MFR] or NP250gT4[TFR]<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

WDU/PMR 2005 2 NONE NP180s/s[p/s][p/p] OR G100s/s[p/s] G100gM[MFR] OR NP180gM[MFR] or<br />

NP250gM[MFR] or NP250gT4[TFR]<br />

WDU/PMR 2005 2 COATED GLASS BASE NP180gM[MFR] or NP180gT[TFR] or<br />

NP250gM[MFR] or NP250gT4[TFR]<br />

NEW / REPLACEMENT<br />

INISULATED<br />

SDI-2000 2 NONE G100s/s[p/s] OR NP180s/s[p/p][p/s] G100gM[MFR] OR NP180gM[MFR] or<br />

NP250gM[MFR] or NP250gT4[TFR]<br />

CDI-2001 2 NONE G100s/s[p/s] OR NP180s/s[p/p][p/s] G100gM[MFR] OR NP180gM[MFR] or<br />

NP250gM[MFR] or NP250gT4[TFR]<br />

WDI-2002 2 NONE G100s/s[p/s] OR NP180s/s[p/p][p/s] G100gM[MFR] OR NP180gM[MFR] or<br />

NP250gM[MFR] or NP250gT4[TFR]<br />

SDI-2000 2 COATED GLASS SHEET NP180gM[MFR] or NP180gT[TFR] or<br />

NP250gM[MFR] or NP250gT4[TFR]<br />

CDI-2001 2 COATED GLASS SHEET NP180gM[MFR] or NP180gT[TFR] or<br />

NP250gM[MFR] or NP250gT4[TFR]<br />

WDI-2002 2 COATED GLASS SHEET NP180gM[MFR] or NP180gT[TFR] or<br />

NP250gM[MFR] or NP250gT4[TFR]<br />

REC-2006 1 NONE NP180gM[MFR] or NP180gT[TFR] or<br />

NP250gM[MFR] or NP250gT4[TFR]<br />

RECOVER<br />

EXISTING ROOF<br />

INSULATION ADDED<br />

REC-2006 2 NONE G100s/s[p/s] OR NP180s/s[p/s][p/p G100gM[MFR] OR NP180gM[MFR] or<br />

NP250gM[MFR] or NP250gT4[TFR]<br />

REC-2006 2 COATED BASE SHEET G100gM[MFR] OR NP180gM[MFR] or<br />

NP250gM[MFR] or NP250gT4[TFR]<br />

COMPANY NAME<br />

NEW/REPLACEMENT<br />

HONEYWELL INTERNATIONAL, INC.<br />

NON-NAILABLE<br />

M-100-MN-NN 2 BLACK ARMOR-ORGANIC MILLENNIUM GMC<br />

M-120-MP-NN 3 2 BLACK ARMOR TC GLASS MILLENNIUM GMC<br />

M-140-MP-NN 3 BLACK ARMOR ORGANIC MILLENNIUM BASE MILLENIUM GMC<br />

M-145-MP-NN 3 MILLENNIUM BASE MILLENIUM SMOOTH MILLENNIUM GMC<br />

M-150-MP-NN 2 NONE MILLENNIUM SMOOTH MILLENNIUM GMC<br />

M-160-MP-NN 4 3 BLACK ARMOR TC GLASS MILLENNIUM GMC<br />

M-100-C-NN 2 MILLENNIUM BASE MILLENNIUM BMC<br />

M-140-C-NN 3 MILLENNIUM BASE MILLENNIUM BASE MILLENNIUM GMC<br />

M-145-C-NN 3 MILLENNIUM BASE MILLENNIUM SMOOTH MOP MILLENNIUM GMC<br />

M-150-C-NN 2 NONE MILLENNIUM SMOOTH MOP MILLENNIUM GMC<br />

M-100-MP-N 2 BLACK ARMOR ORGANIC MILLENNIUM GMC<br />

M-120-MP-NN 4 BLACK ARMOR ORGANIC BASE MILLENNIUM GMC<br />

& 2 BLACK ARMOR TC GLASS IV<br />

M-140-MP-N 3 BLACK ARMOR ORGANIC BASE MILLENNIUM BASE SHEET MILLENNIUM GMC<br />

M-145-MP-NN 3 MILLENNIUM BASE SHEET MILLENNIUM SMOOTH MILLENNIUM GMC<br />

273


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

COMPANY NAME<br />

NEW/REPLACEMENT<br />

HONEYWELL INTERNATIONAL, INC. (continued)<br />

NON-NAILABLE<br />

M-160-MP-NN 5 BLACK ARMOR BASE & MILLENNIUM GMC<br />

3 BLACK ARMOR TC GLASS<br />

M-100-C-N 2 MILLENNIUM BASE SHEET MILLENNIUM GMC<br />

M-140-C-N 3 MILLENNIUM BSE SHEET MILLENNIUM BASE SHEET MILLENNIUM GMC<br />

M-145-C-N 3 MILLENNIUM BASE SHEET MILLENNIUM SMOOTH MOP MILLENNIUM GMC<br />

I-100-MA-NN 2 BLACK ARMOR BASE SHEET INFINITEE 30 GMC<br />

I-105-PM-NN 2 POLYMOP BASE SHEET INFINITEE 30 GMC<br />

I-120-MA-NN 3 2 BLK ARMOR TYPE IV GLASS INFINITEE 30 GMC<br />

I-125-PM-NN 3 2 POLYMOP PLY TYPE IV INFINITEE 30 GMC<br />

I-130-MA-NN 2 NONE INFINITEE 20 SM INFINITEE 30 GMC<br />

I-135-PM-NN 2 NONE INFINITEE 20 SM INFINITEE 30 GMC<br />

I-140-MA-NN 3 BLACK ARMOR BASE SHEET INFINITEE 20 SM<br />

I-145-PM-NN 3 POLYMOP BASE SHEET INFINITEE 20 SM<br />

I-160-MA-NN 4 3 BLK ARMOR TYPE IV GLASS INFINITEE 30 GMC<br />

I-165-PM-NN 4 3 POLYMOP TYPE IV INFINITEE 30 GMC<br />

I-100-C-NN 2 BLACK ARMOR BASE INFINITEE 30 GMC<br />

I-105-C-NN 2 POLYMOP BASE SHEET INFININITEE 30 GMC<br />

I-140-C-NN 3 BLACK ARMOR BSE POLYMOP BASE SHEET INFINITEE 30 GMC<br />

I-145-C-NN 3 POLYMOP BASE SHEET POLYMOP BASE SHEET INFINITEE 30 GMC<br />

I-150-C-NN 3 BLACK ARMOR BASE SHEET INFINITEE 20 SM INFINITEE 30 GMC<br />

I-145-T-NN 3 BLACK ARMOR BASE SHEET INFINITEE ST INFINITEE GTC<br />

NEW/REPLACEMENT<br />

NAILABLE<br />

I-100-MA-N 2 BLACK ARMOR BASE SHEET INFINITEE 30 GMC<br />

I-105-PM-N 2 POLYMOP BASE SHEET INFINITEE 30 GMC<br />

I-120-MA-N 4 BLACK ARMOR BASE SHEET & INFINITEE 30 GMC<br />

2 BLK ARMOR TYPE IV GLASS<br />

I-125-PM-N 4 POLYMOP BASE SHEET & INFINITEE 30 GMC<br />

2 POLY MOP PLY IV<br />

I-140-MA-N 3 BLACK ARMOR BASE SHEET INFINITEE 20 SM INFINITEE 30 GMC<br />

I-145-PM-N 3 POLY MOP BASE SHEET INFINITEE 20 SM INFINTEE 30 GMC<br />

I-160-MA-N 5 BLACK ARMOR BASE SHEET & INFINITEE 30 GMC<br />

3 BLACK ARMOR TYPE IV GLASS<br />

I-165-PM-N 5 POLYMOP BASE SHEET & 3 INFINITEE 30 GMC<br />

POLYMOP PLY IV<br />

I-100-C-N 2 BLACK ARMOR BASE SHEET INFINITEE 30 GMC<br />

I-105-C-N 2 POLYNOIP BASE SHEET INFINITEE 30 GMC<br />

I-140-C-N 3 BLACK ARMOR BASE SHEET POLY MOP BASE SHEET INFINITEE 30 GMC<br />

I-145-C-N 3 POLYMOP BSAE SHEET POLYMOP BSAE SHEET INFINITEE 30 GMC<br />

I-150-C-N 3 BLACK ARMOR BASE SHEET INFINITEE 20 SM INFINITEE 30 GMC<br />

I-100-T-N 2 BLACK ARMOR BASE SHEET INFINITEE GTC<br />

I-140-T-N 3 BLACK ARMOR BASE SHEET INFINITEE ST INFINITEE GTC<br />

NEW/REPLACEMENT<br />

INSULATED<br />

M-100-MN-NN 2 BLACK ARMOR-ORGANIC MILLENNIUM GMC<br />

M-120-MP-NN 3 2 BLACK ARMOR TC GLASS MILLENNIUM GMC<br />

M-140-MP-NN 3 BLACK ARMOR ORGANIC MILLENNIUM BASE MILLENNIUM GMC<br />

M-145-MP-NN 3 MILLENNIUM BASE MILLENIUM SMOOTH MILLENNIUM GMC<br />

M-150-MP-NN 2 NONE MILLENNIUM SMOOTH MILLENNIUM GMC<br />

M-160-MP-NN 4 3 BLACK ARMOR TC GLASS MILLENNIUM GMC<br />

M-100-C-NN 2 MILLENNIUM BASE MILLENNIUM BMC<br />

M-140-C-NN 3 MILLENNIUM BASE MILLENNIUM BASE MILLENNIUM GMC<br />

M-145-C-NN 3 MILLENNIUM BASE MILLENNIUM SMOOTH MOP MILLENNIUM GMC<br />

M-150-C-NN 2 NONE MILLENNIUM SMOOTH MOP MILLENNIUM GMC<br />

I-100-MA-NN 2 BLACK ARMOR BASE SHEET INFINITEE 30 GMC<br />

I-105-PM-NN 2 POLYMOP BASE SHEET INFINITEE 30 GMC<br />

I-120-MA-NN 3 2 BLK ARMOR TYPE IV GLASS INFINITEE 30 GMC<br />

I-125-PM-NN 3 2 POLYMOP PLY TYPE IV INFINITEE 30 GMC<br />

I-130-MA-NN 2 NONE INFINITEE 20 SM INFINITEE 30 GMC<br />

I-135-PM-NN 2 NONE INFINITEE 20 SM INFINITEE 30 GMC<br />

I-140-MA-NN 3 BLACK ARMOR BASE SHEET INFINITEE 20 SM<br />

I-145-PM-NN 3 POLYMOP BASE SHEET INFINITEE 20 SM<br />

I-160-MA-NN 4 3 BLK ARMOR TYPE IV GLASS INFINITEE 30 GMC<br />

I-165-PM-NN 4 3 POLYMOP TYPE IV INFINITEE 30 GMC<br />

I-100-C-NN 2 BLACK ARMOR BASE INFINITEE 30 GMC<br />

I-105-C-NN 2 POLYMOP BASE SHEET INFININITEE 30 GMC<br />

I-140-C-NN 3 BLACK ARMOR BSE POLYMOP BASE SHEET INFINITEE 30 GMC<br />

I-145-C-NN 3 POLYMOP BASE SHEET POLYMOP BASE SHEET INFINITEE 30 GMC<br />

I-150-C-NN 3 BLACK ARMOR BASE SHEET INFINITEE 20 SM INFINITEE 30 GMC<br />

I-145-T-NN 3 BLACK ARMOR BASE SHEET INFINITEE ST INFINITEE GTC<br />

274


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

NEW / REPLACEMENT<br />

ICA, INC.<br />

NON-NAILABLE<br />

PS1-NN 1 NONE ICA PREMIUM APP SMOOTH<br />

PS2-NN 2 NONE ICA PREMIUM APP SMOOTH ICA PREMIUM APP SMOOTH<br />

PM1-NN 1 NONE ICA PREMIUM APP MINERAL OR SLATE -<br />

PM2-NN 2 NONE ICA PREMIUM APP SMOOTH ICA PREMIUM APP MINERAL OR SLATE<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

PS1-N 1 ICA FIBERGLASS 62 BASE SHEET ICA PREMIUM APP SMOOTH<br />

PS2-N 2 ICA FIBERGLASS 62 BASE SHEET ICA PREMIUM APP SMOOTH ICA PREMIUM APP SMOOTH<br />

PM1-N 1 ICA FIBERGLASS 62 BASE SHEET ICA PREMIUM APP MINERAL OR SLATE -<br />

PM2-N 2 ICA FIBERGLASS 62 BASE SHEET ICA PREMIUM APP SMOOTH ICA PREMIUM APP MINERAL OR SLATE<br />

NEW / REPLACEMENT<br />

INSULATED<br />

PS1-NI 1 ICA FIBERGLASS 62 BASE SHEET ICA PREMIUM APP SMOOTH<br />

PS2-NI 2 ICA FIBERGLASS 62 BASE SHEET ICA PREMIUM APP SMOOTH ICA PREMIUM APP SMOOTH<br />

PM1-NI 1 ICA FIBERGLASS 62 BASE SHEET ICA PREMIUM APP MINERAL -<br />

PM2-NI 2 ICA FIBERGLASS 62 BASE SHEET ICA PREMIUM APP SMOOTH ICA PREMIUM APP MINERAL OR SLATE<br />

PS1-NNI 1 ICA FIBERGLASS 62 BASE SHEET ICA PREMIUM APP SMOOTH -<br />

PS2-NNI 2 ICA FIBERGLASS 62 BASE SHEET ICA PREMIUM APP SMOOTH ICA PREMIUM APP SMOOTH<br />

PM1-NNI 1 ICA FIBERGLASS 62 BASE SHEET ICA PREMIUM APP MINERAL -<br />

PM2-NNI 2 ICA FIBERGLASS 62 BASE SHEET ICA PREMIUM APP SMOOTH ICA PREMIUM APP MINERAL OR SLATE<br />

RECOVER See New / Replacement: Nailable and Non-nailable<br />

EXISTING ROOF<br />

RECOVER<br />

EXISTING ROOF See New / Replacement Insulated<br />

INSULATION ADDED<br />

Company Name<br />

NEW / REPLACEMENT<br />

IKO INDUSTRIES INC.<br />

NAILABLE<br />

SM 201 4 NO. 25 GLASS BASE TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP-250-CAP<br />

SM 202 4 NO. 25 GLASS BASE TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP-180-CAP<br />

SM 210 3 NO. 25 GLASS BASE TYPE IV GLASS PLY MODIFLEX MP-250-CAP<br />

SM 211 3 NO. 25 GLASS BASE TYPE 6 GLASS PLY MODIFLEX MP-250-CAP<br />

SM 212 3 NO. 25 GLASS BASE NO. 25 GLSS BASE MODIFLEX MP-250-CAP<br />

SM 213 3 NO. 25 GLASS BASE TYPE IV GLASS PLY MODIFLEX MP-180-CAP<br />

SM 214 3 NO. 25 GLASS BASE MODIFLEX MP-180-SS MODIFLEX MP-180-CAP<br />

SM 215 3 NO. 25 GLASS BASE MODIFLEX MP-95-SS MODIFLEX-MF-95-CAP FR<br />

SM 220 3 NO. 25 GLASS BASE TYPE 6 GLASS PLY TORCHFLEX TP 260-CAP<br />

SM 221 3 NO. 25 GLASS BASE MODIFLEX MP-180-FS TORCHFLEX TP-180-CAP<br />

SM 230 3 NO. 25 GLASS BASE TORCHFLEX TP-180-FF TORCHFLEX TP-180-CAP<br />

SM 240 3 NO. 25 GLASS BASE MODIFLEX MP-180-SS MODIFLEX MP-180-CAP<br />

SM 241 3 NO. 25 GLASS BASE MODIFLEX MS-95-SS MODIFLEX MF-96-CAP-FR<br />

SN 250 4 NO. 25 GLASS BASE TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP-250-CAP<br />

SN 251 4 NO. 25 GLASS BASE TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP=180-CAP<br />

SN 260 3 NO. 25 GLASS BASE TYPE IV GLASS PLY MODIFLEX MP-250-CAP<br />

SN 261 3 NO. 25 GLASS BASE TYPE 6 GLASS PLY MODIFLEX MP-250-CAP<br />

SN 262 3 NO. 25 GLASS BASE NO. 25 GLSS BASE MODIFLEX MP-250-CAP<br />

SN 263 3 NO. 25 GLASS BASE TYPE IV GLASS PLY MODIFLEX MP-180-CAP<br />

SN 264 3 NO. 25 GLASS BASE MODIFLEX MP-180-SS MODIFLEX MP-180-CAP<br />

SN 265 3 NO. 25 GLASS BASE MODIFLEX MF-95-SS MODIFLEX MF-95-CAP-FR<br />

2N 270 3 NO. 25 GLASS BASE TYPE 6 GLASS PLY TORCHFLEX TP-250-CAP<br />

SN 271 3 NO. 25 GLASS BASE MODIFLEX MP-180-FS TORCHFLEX TP-180-CAP<br />

SN 280 3 NO. 25 GLASS BASE TORCHFLEX TP-180-FF TORCHFLEX TP-180-CAP<br />

SN 290 3 NO. 25 GLASS BASE MODIFLEX MP-180-SS MODIFLEX MP-180-CAP<br />

SN 291 3 NO. 25 GLASS BASE MODIFLEX MF-95-SS MODIFLEX-MF-95-CAP FR<br />

AM 400 3 NO. 25 GLASS BASE MODIFLEX MF-95-FS AMROURPLAST GRANULAR<br />

AM 401 3 NO. 25 GLASS BASE MODIFLEX MF-95-FS ARMOURPLASST CLASSIC<br />

AM 410 3 NO. 25 GLASS BASE TORCHFLEX TF-95-FF ARMOURPLAST GRANULAR<br />

AM 411 3 NO. 25 GLASS BASE TORCHFLEX TF-95-FF ARMOURPLAST CLASSIC<br />

AN 450 3 NO. 25 GLASS BASE MODIFLEX MF-95-FS ARMOURPLAST GRANULAR<br />

AN 451 3 NO. 25 GLASS BASE MODIFLEX MF-95-FS ARMOURPLAST CLASSIC<br />

AN 460 3 NO. 25 GLASS BASE TORCHFLEX TF-95-FF ARMOURPLAST GRANULAR<br />

AN 461 3 NO. 25 GLASS BASE TORCHFLEX TF-95-FF ARMOURPLAST CLASSIC<br />

NEW / REPLACEMENT<br />

INSULATED<br />

AI 300 3 MODIFLEX MF-95-FS ARMOURPLAST CLASSIC ARMOURPLAST GRANULAR<br />

AI 301 3 NO. 25 GLASS BASE ARMOURPLAST CLASSIC ARMOURPLAST GRANULAR<br />

AI 310 3 ARMOURPLAST CLASSIC ARMOURPLAST CLASSIC ARMOURPLAST GRANULAR<br />

275


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

NEW / REPLACEMENT<br />

INSULATED<br />

IKO INDUSTRIES INC. (continued)<br />

AI 320 3 TYPE 6 GLASS PLY TYPE 6 GLASS PLY ARMOURPLAST GRANULAR<br />

AI 321 3 MODIFLEX MF-95-FS MODIFLEX MF-95-FS ARMOURPLAST GRANULAR<br />

AI 330 3 NO. 25 GLASS BASE ARMOURPLAST CLASSIC ARMOURPLAST CLASSIC<br />

AI 340 3 MODIFLEX MF-95-FS MODIFLEX MF-95-FS<br />

AI 350 3 TYPE 6 GLASS PLY TYPE 6 GLASS PLY<br />

AI 351 3 NO. 25 GLASS BASE MODIFLEX MF-95-FS<br />

AI 352 3 NO. 25 GLASS BASE MODIFLEX MF-95-FS<br />

AI 353 3 NO. 25 GLASS BASE MODIFLEX MF-95-FS<br />

AI 354 3 NO. 25 GLASS BASE MODIFLEX MF-95-FS<br />

AI 360 2 MODIFLEX MF-95-FS ARMOURPLAST GRANULAR<br />

AI 361 2 MODIFLEX MF-95-FS ARMOURPLAST CLASSIC<br />

BI 8010 4 TYPE 6 GLASS PLY TYPE 6 GLASS PLY TYPE 6 GLASS PLY TYPE 6 GLASS PLY<br />

BI 8011 4 TYPE IV GLASS PLY TYPE IV GLASS PLY TYPE IV GLASS PLY TYPE IV GLASS PLY<br />

BI 8012 4 NO. 15 PERFORATED NO. 15 PERFORATED NO. 15 PERFORATED NO. 15 PERFORATED<br />

BI 8020 3 TYPE 6 GLASS PLY TYPE 6 GLASS PLY TYPE 6 GLASS PLY<br />

BI 8021 3 TYPE IV GLASS PLY TYPE IV GLASS PLY TYPE IV GLASS PLY<br />

BI 8030 4 NO. 15 PERFORATED NO. 15 PERFORATED NO. 15 PERFORATED NO. 15 PERFORATED<br />

SI 101 4 TYPE IV GLASS PLY TYPE IV GLASS PLY TYPE IV GLASS PLY MODIFLEX MP-250-CAP<br />

SI 102 4 TYPE 6 GLASS PLY TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP-250-CAP<br />

SI 103 4 NO. 25 GLASS BASE TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP-250-CAP<br />

SI 110 4 TYPE 6 GLASS PLY TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP-180-CAP<br />

SI 111 4 NO. 25 GLASS BASE TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP-180-CAP<br />

SI 112 4 TYPE IV GLASS PLY TYPE IV GLASS PLY TYPE IV GLASS PLY MODIFLEX MP-180-CAP<br />

SI 113 4 NO. 25 GLASS BASE TYPE IV GLASS PLY TYPE IV GLASS PLY MODIFLEX MP-180-CAP<br />

SI 120 3 TYPE 6 GLASS PLY MODIFLEX MF-95-SS MODIFLEX MP-250-CAP<br />

SI 130 3 NO. 25 GLASS BASE MODIFLEX MP180-SS MODIFLEX MP-180-CAP<br />

SI 131 3 NO. 25 GLASS BASE TYPE 6 GLASS PLY MODIFLEX MP-250-CAP<br />

SI 132 3 TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP-180-CAP<br />

SI 133 3 NO. 25 GLASS BASE TYPE 6 GLASS PLY MODIFLEX MP-180-CAP<br />

SI 134 3 TYPE IV GLASS PLY TYPE IV GLASS PLY MODIFLEX MP-250-CAP<br />

SI 135 3 TYPE IV GLASS PLY TYPE IV GLASS PLY MODIFLEX MP-180-CAP<br />

SI 136 3 TYPE 6 GLASS PLY MODIFLEX MP=95-SS MODIFLEX MP-180-CAP<br />

SI 137 3 NO. 25 GLASS BASE TYPE IV GLASS PLY MODIFLEX MP-250-CAP<br />

SI 138 3 NO. 25 GLASS BASE TYPE IV GLASS PLY MODIFLEX MP-180-CAP<br />

SI 140 3 NO. 25 GLASS BASE MODIFLEX MP-180-FS TORCHFLEX TP-180-CAP<br />

SI 145 3 NO. 25 GLASS BASE TORCHFLEX TP-180-FF TORCHFLEX TP-180-CAP<br />

SI 150 3 NO. 25 GLASS BASE TORCHFLEX TP-180-FF TORCHFLEX TP-180-CAP<br />

SI 155 3 NO. 25 GLASS BASE MODIFLEX MP-180-SS MODIFLEX MP-180-CAP<br />

SI 160 2 MODIFLEX MP-180-SS MODIFLEX MP-250-CAP<br />

SI 165 2 MODIFLEX MP-180-FS TORCHFLEX TP-250-CAP<br />

SI 170 2 MODIFLEX MF-95-SS MODIFLEX MP-250-CAP<br />

SI 171 2 MODIFLEX MP=180-SS MODIFLEX MP-180-CAP<br />

SI 172 2 MODIFLEX MP-95-SS MODIFLEX MP-180-CAP<br />

SI 173 2 TYPE 6 GLASS PLY MODIFLEX MP-250-CAP<br />

SI 174 2 TYPE 6 GLASS PLY MODIFLEX MP-180-CAP<br />

SI 175 2 TYPE IV GLASS PLY MODIFLEX MP-250-CAP<br />

SI 176 2 TYPE IV GLASS PLY MODIFLEX MP-180-CAP<br />

SI 177 2 MODIFLEX MF-95-SS MODIFLEX MF-95-CAP FR<br />

SI 180 2 MODIFLEX MF-95-FS TORCHFLEX TP-250-CAP<br />

SI 181 2 NO. 25 GLASS BASE TORCHFLEX TP-250-CAP<br />

SI 190 2 MODIFLEX MF-95-SS MODIFLEX MP-250-CAP<br />

SI 191 2 MODIFLEX MF-95-SS MODIFLEX MP-180-CAP<br />

SI 192 2 MODIFLEX MF-95-SS MODIFLEX MF-95-CAP FR<br />

CAP SHEET SUBSTITUTION:<br />

In the above system assemblies (except in cold applied systems), the following cap sheet substitutions may be made without affecting the applicable limited warranty:<br />

a) Modiflex MP-180-Cap FR or Modiflex MP-180-Cap FR Premium may be substituted for Modiflex MP-180-Cap<br />

b) Torchflex TP-180-Cap Fr or Torchflex TP-180-Cap FR Premium may be substituted for Torchflex TP-180-Cap<br />

RECOVER<br />

EXISTING ROOF<br />

SR 501 4 TYPE 6 GLASS PLY TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP-180-CAP<br />

SR 502 4 NO. 25 GLASS BASE TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP-180-CAP<br />

SR 510 4 NO. 25 GLASS BASE TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP-180-CAP<br />

SR 520 3 NO. 25 GLASS BASE TYPE 6 GLASS PLY MODIFLEX MP-250-CAP<br />

SR 521 3 NO. 25 GLASS BASE TYPE 6 GLASS PLY MODIFLEXM P-180-CAP<br />

SR 522 3 TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP-250-CAP<br />

SR 523 3 TYPE 6 GLASS PLY TYPE 6 GLASS PLY MODIFLEX MP-180-CAP<br />

SR 530 3 NO. 25 GLASS BASE TYPE 6 GLASS PLY MODIFLEXM P-250-CAP<br />

SR 531 3 NO. 25 GLASS BASE TYPE 6 GLASS PLY MODIFLEX MP-180-CAP<br />

SR 540 2 TYPE 6 GLASS PLY MODIFLEX MP-250-CAP<br />

SR 541 2 TYPE 6 GLASS PLY MODIFLEX MP-180-CAP<br />

276


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

IKO INDUSTRIES INC. (continued)<br />

RECOVER<br />

EXISTING ROOF<br />

SR 542 2 TYPE 6 GLASS PLY MODIFLEX MP-180-CAP-FR<br />

SR 543 2 NO. 25 GLASS BASE MODIFLEX MP-250-CAP<br />

SR 544 2 NO. 25 GLASS BASE MODIFLEX MP-180-CAP<br />

SR 545 2 N0. 25 GLASS BASE MODIFLEX MP-180-CAP FR<br />

SR 550 2 NO. 25 GLASS BASE MODIFLEX MP-250-CAP<br />

S5 551 2 NO. 25 GLASS BASE MODIFLEX MP-180-CAP<br />

SR 552 2 NO. 25 GLASS BASE MODIFLEX MP-180-CAP-FR<br />

CAP SHEET SUBSTITUTION<br />

In the above three or fouro ply system assemblies (except in cold applied systems), the following cap sheet substitutions may be made without affecting the applicable limited warranty.<br />

Modiflex MP-180-Cap FR or Modiflex MP-180-Cap FR Premium may be substituted for Modiflex MP-180-Cap<br />

AR 601 3 NO. 25 GLASS BASE ARMOURPLAST CLASSIC ARMOURPLAST GRANULAR<br />

AR 602 3 NO. 25 GLASS BASE ARMOURPLAST CLASSIC ARMOURPLAST GRANULAR<br />

AR 610 2 MODIFLEX MF-95-FS ARMOURPLAST GRANULAR<br />

AR 611 2 MODIFLEX MF-95-FS ARMOURPLAST CLASSIC<br />

AR 620 2 MODIFLEX MF-95-FS ARMOURPLAST GRANULAR<br />

AR 621 2 MODIFLEX MF-95-FS ARMOURPLAST CLASSIC<br />

AR 622 2 NO. 25 GLASS BASE ARMOURPLAST GRANULAR<br />

AR 623 2 NO. 25 GLASS BASE ARMOURPLAST CLASSIC<br />

AR 630 2 NO. 25 GLASS BASE ARMOURPLAST GRANULAR<br />

AR 631 2 NO. 25 GLASS BASE ARMOURPLAST CLASSIC<br />

RECOVER<br />

EXISTING ROOF<br />

INSULATED ADDED<br />

Company Name<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

JOHNS MANVILLE INTERNATIONAL, INC.<br />

2CID 2 GLASPLY PREMIER DYNAKAP, DYNAKAP FR,<br />

DYNAMAX, OR DYNAMAX FR<br />

2CID 2 GLASBASE DYNAKAP, DYNAKAP FR,<br />

DYNAMAX, OR DYNAMAX FR<br />

2CID 2 NONE DYNABASE DYNAKAP, DYNAKAP FR,<br />

DYNAPLY, DYNALASTIC 180S DYNAMAX, OR DYNAMAX FR<br />

2CID-C 2 GLASBASE DYNAKAP, DYNAKAP FR,<br />

DYNAMAX, OR DYNAMAX FR<br />

2CID-C 2 NONE DYNABASE DYNAKAP, DYNAKAP FR,<br />

DNYAPLY DYNALASTIC 180S DYNAMAX, OR DYNAMAX FR<br />

2CIG 2 GLASPLY PREMIER OR DYNAPLY OR DYNAKAP<br />

GLASBASE<br />

2CIG 2 NONE DYNABASE DYNAPLY OR DYNAKAP<br />

2FID 2 GLASPLY IV OR GLASBASE DYNAGLAS OR DYNAGLAS FR<br />

2FID 2 NONE DYNABASE DYNAGLAS, DYNAGLAS 30FR,<br />

DYNALASTIC 180S DYNAPLY<br />

OR DYNAGLAS FR<br />

2FID-C 2 NONE DYNABASE DYNAGLAS, DYNAGLAS 30FR,<br />

DYNAPLY, DC 180S<br />

OR DYNAGLAS FR<br />

2PID 2 GLASPLY PREMIER DYNALASTIC 180, DYNALASTIC 180 FR,<br />

DYNALASTIC 250, OR DYNALASTIC 250 FR<br />

2PID 2 PP 28 GLASBASE DYNALASTIC 180, DYNALASTIC 180 FR,<br />

DYNALASTIC 250, OR DYNALASTIC 250 FR<br />

2PID 2 NONE DYNALASTIC 180S DYNALASTIC 180, DYNALASTIC 180 FR,<br />

DYNABASE, DYNAPLY DYNALASTIC 250, OR DYNALASTIC 250 FR<br />

3CID 3 TWO GLASPLY PREMIER DYNAKAP, DYNAKAP FR,<br />

DYNAMAX, OR DYNAMAX FR<br />

3CID-C 3 TWO GLASPLY PREMIER DYNAKAP, DYNAKAP FR,<br />

DYNAMAX, OR DYNAMAX FR<br />

3FID 3 TWO GLASPLY PREMIER DYNAGLAS OR DYNAGLAS FR<br />

3FID-C 3 TWO GLASPLY PREMIER DYNAGLAS OR DYNAGLAS FR<br />

3PID 3 TWO GLASPLY PREMIER DYNALASTIC 180, DYNALASTIC 180 FR,<br />

DYNALASTIC 250, OR DYNALASTIC 250 FR<br />

3PID-C 3 TWO GLASPLY PREMIER DYNALASTIC 180, DYNALASTIC 180 FR,<br />

DYNALASTIC 250, OR DYNALASTIC 250 FR<br />

2CBS-W/2PBS-W 2 GLASBASE, PP28 TRICOR, BICOR,<br />

OR APPEX SERIES<br />

2CBN-W/2PBN-W 2 GLASBASE, PP28 TRICOR M, TRICOR M FR,<br />

OR APPEX SERIES<br />

277


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

JOHNS MANVILLE INTERNATIONAL, INC. (continued)<br />

3CBS-W/3PBS-W 3 GLASBASE, PP28 JOHNS MANVILLE APP BASE TRICOR, BICOR,<br />

OR APPEX SERIES<br />

3CBN-W/3PBN-W 3 GLASBASE, PP28 JOHNS MANVILLE APP BASE TRICOR M, TRICOR M FR<br />

OR APPEX SERIES<br />

2F1O 2 DYNAWELD BASE DYNAWELD CAP FR<br />

3F10 (HW) 3 DYNAWELD BASE DYNAWELD BASE DYNAWELD CAP FR<br />

3F10 (A1T) HW 3 TWO GLASS PLY DYNAWELD CAP FR<br />

4F10 (HW) A1T 4 THREE GLASS PLY DYNAWELD CAP FR<br />

PREMIER IV<br />

Company Name<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

2CND 2 VENTSULATION OR DYNAKAP, DYNAKAP FR,<br />

PP 28GLASBASE DYNAMAX, OR DYNAMAX FR<br />

2CND 2 NONE DYNABASE DYNAKAP, DYNAKAP FR,<br />

DYNAMAX, OR DYNAMAX FR<br />

2CND-C 2 VENTSULATION OR DYNAKAP, DYNAKAP FR,<br />

PP 28 GLASBASE DYNAMAX, OR DYNAMAX FR<br />

2CND-C 2 NONE DYNABASE DYNAKAP, DYNAKAP FR,<br />

DYNAMAX, OR DYNAMAX FR<br />

2CNG 2 VENTSULATION OR DYNAKAP, DYNAKAP FR,<br />

PP 28 GLASBASE DYNAMAX, OR DYNAMAX FR<br />

2CNG 2 NONE DYNABASE DYNAKAP, DYNAKAP FR,<br />

DP DC 180S<br />

DYNAMAX, OR DYNAMAX FR<br />

2FND 2 VENTSULATION OR DYNAGLAS OR DYNAGLAS FR<br />

PP 28 GLASBASE<br />

2FND 2 NONE DYNABASE DYNAGLAS, DYNAGLAS 30FR,<br />

DP DC 180S<br />

OR DYNAGLAS FR<br />

2FND-C 2 VENTSULATION OR DYNAGLAS OR DYNAGLAS FR<br />

PP 28 GLASBASE<br />

2PND 2 VENTSULATION OR DYNALASTIC 180, DYNALASTIC 180 FR,<br />

PP 28 GLASBASE DYNALASTIC 250, OR DYNALASTIC 250 FR<br />

2PND 2 NONE DYNALASTIC 180S DYNALASTIC 180, DYNALASTIC 180 FR,<br />

DYNALASTIC 250, OR DYNALASTIC 250 FR<br />

2PND-C 2 VENTSULATION OR DYNALASTIC 180, DYNALASTIC 180 FR,<br />

PP 28 GLASBASE DYNALASTIC 250, OR DYNALASTIC 250 FR<br />

3CND 3 VENTSULATION OR DYNAKAP, DYNAKAP FR,<br />

PP 28 GLASBASE DYNAMAX, OR DYNAMAX FR<br />

3CLD 3 VENTSULATION DYNABASE DYNAKAP, DYNAKAP FR,<br />

DYNAMAX, OR DYNAMAX FR<br />

3FND 3 VENTSULATION OR DYNAGLAS OR DYNAGLAS FR<br />

PP 28 GLASBASE<br />

3FLD 3 VENTSULATION DYNABASE DYNAGLAS, DYNAGLAS 30 FR,<br />

OR DYNAGLAS FR<br />

3PND 3 VENTSULATION OR DYNALASTIC 180, DYNALASTIC 180 FR,<br />

3PLD 3 VENTSULATION DYNALASTIC 180S DYNALASTIC 180, DYNALASTIC 180 FR,<br />

DYNALASTIC 250, OR DYNALASTIC 250 FR<br />

2CNS-W/2PNS-W 2 GLASBASE, PP28 TRICOR, BICOR,<br />

OR APPEX SERIES<br />

2CNS-W/2PNS-W 2 NONE JOHNS MANVILLE APP BASE TRICOR, BICOR,<br />

OR APPEX SERIES<br />

2CNN-W/2PNN-W 2 GLASBASE, PP28 CLASSIC SERIES, TRICOR M,<br />

TRICOR M FR, OR APPEX SERIES<br />

2CNN-W/2PNN-W 2 NONE JOHNS MANVILLE APP BASE TRICOR M, TRICOR M FR<br />

OR APPEX SERIES<br />

3CNS-W/3PNS-W 3 GLASBASE, PP28 JOHNS MANVILLE APP BASE TRICOR, BICOR,<br />

OR APPEX SERIES<br />

3CNS-W/3PNS-W 3 NONE JOHNS MANVILLE APP BASE APPEX SERIES TRICOR, BICOR<br />

OR APPEX SERIES<br />

3CNN-W/3PNN-W 3 GLASBASE, PP28 JOHNS MANVILLE APP BASE CLASSIC SERIES, TRICOR M,<br />

TRICOR M FR, OR APPEX SERIES<br />

3CNN-W/3PNN-W 3 NONE JOHNS MANVILLE APP BASE APPEX SERIES TRICOR M, TRICOR MFR,<br />

OR APPEX SERIES<br />

3FLD (HW) 3 PP28, GLASBASE, DYNAWELD BASE DYNAWELD CAP FR<br />

OR VENTSULATION<br />

NEW / REPLACEMENT<br />

INSULATED<br />

1CIN-W/1PIS-W 1 NONE TRICOR, BICOR,<br />

OR APPEX SERIES<br />

1CIN-W/1PIN-W 1 NONE TRICOR M, TRICOR M FR,<br />

OR APPEX SERIES<br />

2CIS-W/2PIS-W 2 GLASBASE, PP28 TRICOR, BICOR,<br />

OR APPEX SERIES<br />

2CIS-W/2PIS-W 2 NONE JOHNS MANVILLE APP BASE TRICOR M, TRICOR M FR<br />

OR APPEX SERIES<br />

278


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

JOHNS MANVILLE INTERNATIONAL, INC. (continued)<br />

2CIN-W/2PIN-W 2 GLASBASE, PP28 TRICOR M, TRICOR M FR,<br />

OR APPEX SERIES<br />

2CIN-W/2PIN-W 2 NONE JOHNS MANVILLE APP BASE TRICOR M, TRICOR M FR<br />

OR APPEX SERIES<br />

3CIS-W/3PIS-W 3 GLASBASE, PP28 JOHNS MANVILLE APP BASE TRICOR, BICOR,<br />

OR APPEX SERIES<br />

3CIS-W/3PIS-W 3 NONE JOHNS MANVILLE APP BASE APPEX SERIES TRICOR, BICOR<br />

APPEX SERIES<br />

3CIN-W/3PIN-W 3 GLASBASE, PP28 JOHNS MANVILLE APP BASE TRICOR M, TRICOR M FR<br />

OR APPEX SERIES<br />

3CIN-W/3PIN-W 3 NONE JOHNS MANVILLE APP BASE APPEX SERIES TRICOR M, TRICOR MFR,<br />

OR APPEX SERIES<br />

RECOVER<br />

EXISTING ROOF See New / Replacement, Non-nailable and Insulated<br />

INSULATION ADDED<br />

Company Name<br />

KOPPERS INDUSTRIES, INC.<br />

New / Replacement<br />

Non-Nailable<br />

403 2 KOPPERS BASE SHEET 2040-S, 2040-M<br />

415 2 KOPPERS BASE SHEET 2041-S, 2041-M<br />

415 2 KOPPERS BASE SHEET 2045-M<br />

New / Replacement<br />

Nailable<br />

401 2 KOPPERS BASE SHEET 2040-S, 2040-M<br />

402 2 KOPPERS BASE SHEET 2040-S, 2040-M<br />

412 2 KOPPERS BASE SHEET 2041-S, 2041-M<br />

412 2 KOPPERS BASE SHEET 2045-M<br />

414 2 KOPPERS BASE SHEET 2041-S, 2041-M<br />

427 3 KOPPERS BASE SHEET 2045 MFR CAP<br />

New / Replacement<br />

Insulated<br />

404 2 KOPPERS BASE SHEET 2040-S, 2040-M<br />

416 2 KOPPERS BASE SHEET 2041-S, 2041-M<br />

416 2 KOPPERS BASE SHEET 2045-M<br />

428 3 KOPPERS BASE SHEET 2045 MFR CAP<br />

Recover<br />

Existing <strong>Roof</strong><br />

406 2 KOPPERS BASE SHEET 2040-S, 2040-M<br />

418 2 KOPPERS BASE SHEET 2041-S, 2041-M<br />

418 2 KOPPERS BASE SHEET 2045-M<br />

Recover Existing <strong>Roof</strong><br />

Insulation Added<br />

405 2 KOPPERS BASE SHEET 2040-S, 2040-M<br />

405 2 KOPPERS BASE SHEET 2050-S<br />

417 2 KOPPERS BASE SHEET 2041-S, 2041-M<br />

417 2 KOPPERS BASE SHEET 2045-M<br />

429 3 KOPPERS BASE SHEET 2045-MFR CAP<br />

Company Name<br />

MALARKEY ROOFING COMPANY<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

M2-CXB 2 #602 ARCTIC SHIELD #601 PREMIUM MINERAL<br />

M2-DXB 2 #603 SUPERBASE #601 PREMIUM MINERAL<br />

M2-EXB 2 #605 PANOPLY #601 PREMIUM MINERAL<br />

M3-BHB 3 #501 PREMIUM I #500 PREMIUM #601 PREMIUM MINERAL<br />

M3-BIB 3 #501 PREMIUM I #506 SUPER 6 #601 PREMIUM MINERAL<br />

M3-BBB 3 #501 PREMIUM I #501 PREMIUM I #601 PREMIUM MINERAL<br />

M3-BCB 3 #501 PREMIUM I #602 ARCTIC SHIELD #601 PREMIUM MINERAL<br />

M3-BDB 3 #501 PREMIUM I #603 SUPER BASE #601 PREMIUM MINERAL<br />

M3-EHB 3 #605 PANOPLY #500 PREMIUM #601 PREMIUM MINERAL<br />

M3-EIB 3 #605 PANOPLY #506 SUPER 6 #601 PREMIUM MINERAL<br />

M3-EBB 3 #605 PANOPLY #501 PREMIUM I #601 PREMIUM MINERAL<br />

M3-EEB 3 #605 PANOPLY #605 PANOPLY #601 PREMIUM MINERAL<br />

279


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

MALARKEY ROOFING COMPANY (continued)<br />

NEW / REPLACEMENT<br />

NON-NAILABLE (continued)<br />

M3-FHB 3 #1000 ESHAVENT #500 PREMIUM #601 PREMIUM 1 MINERAL<br />

M3-FIB 3 #1000 ESHAVENT #506 SUPER 6 #601 PREMIUM 1 MINERAL<br />

M3-FBB 3 #1000 ESHAVENT #501 PREMIUM I #601 PREMIUM 1 MINERAL<br />

M3-FEB 3 #1000 ESHAVENT #605 PANOPLY #601 PREMIUM 1 MINERAL<br />

M4-BHB 4 #501 PREMIUM I #500 PREMIUM #601 PREMIUM 1 MINERAL<br />

M4-BIB 4 #501 PREMIUM I #506 SUPER 6 #601 PREMIUM 1 MINERAL<br />

M4-BBB 4 #501 PREMIUM I #501 PREMIUM I #601 PREMIUM 1 MINERAL<br />

M4-EBB 4 #605 PANOPLY #501 PREMIUM I #601 PREMIUM 1 MINERAL<br />

M4-EHB 4 #1000 ESHAVENT #500 PREMIUM #601 PREMIUM 1 MINERAL<br />

M4-FIB 4 #1000 ESHAVENT #506 SUPER 6 #601 PREMIUM 1 MINERAL<br />

M4-FBB 4 #1000 ESHAVENT #501 PREMIUM I #601 PREMIUM 1 MINERAL<br />

M4-FEB 4 #1000 ESHAVENT #605 PANOPLY #601 PREMIUM 1 MINERAL<br />

M5-EIB 5 #501 PREMIUM I #506 SUPER 6 #601 PREMIUM 1 MINERAL<br />

M5-EHB 5 #605 PANOPLY #500 PREMIUM #601 PREMIUM 1 MINERAL<br />

M5-BIB 5 #605 PANOPLY #506 SUPER 6 #601 PREMIUM 1 MINERAL<br />

M2-CXC 2 #602 ARCTIC SHIELD #625 PARAGON MINERAL<br />

M2-DXC 2 #603 SUPERBASE #625 PARAGON MINERAL<br />

M2-EXC 2 #605 PANOPLY #625 PARAGON MINERAL<br />

M3-BHC 3 #501 PREMIUM I #500 PREMIUM #625 PARAGON MINERAL<br />

M3-BIC 3 #501 PREMIUM I #506 SUPER 6 #625 PARAGON MINERAL<br />

M3-BBC 3 #501 PREMIUM I #501 PREMIUM I #625 PARAGON MINERAL<br />

M3-EHC 3 #605 PANOPLY #500 PREMIUM #625 PARAGON MINERAL<br />

M3-EIC 3 #605 PANOPLY #506 SUPER 6 #625 PARAGON MINERAL<br />

M3-EBC 3 #605 PANOPLY #501 PREMIUM I #625 PARAGON MINERAL<br />

M3-EEC 3 #605 PANOPLY #605 PANOPLY #625 PARAGON MINERAL<br />

M3-FHC 3 #1000 ESHAVENT #500 PREMIUM #625 PARAGON MINERAL<br />

M3-FIC 3 #1000 ESHAVENT #506 SUPER 6 #625 PARAGON MINERAL<br />

M3-FBC 3 #1000 ESHAVENT #501 PREMIUM I #625 PARAGON MINERAL<br />

M3-FCC 3 #1000 ESHAVENT #602 ARCTIC SHIELD #625 PARAGON MINERAL<br />

M3-FDC 3 #1000 ESHAVENT #603 SUPERBASE #625 PARAGON MINERAL<br />

M3-FEC 3 #1000 ESHAVENT #605 PANOPLY #625 PARAGON MINERAL<br />

M4-BHC 4 #501 PREMIUM I #500 PREMIUM #625 PARAGON MINERAL<br />

M4-BIC 4 #501 PREMIUM I #506 SUPER 6 #625 PARAGON MINERAL<br />

M4-BBC 4 #501 PREMIUM I #501 PREMIUM I #625 PARAGON MINERAL<br />

M4-EHC 4 #605 PANOPLY #500 PREMIUM #625 PARAGON MINERAL<br />

M4-EIC 4 #605 PANOPLY #506 SUPER 6 #625 PARAGON MINERAL<br />

M4-EBC 4 #605 PANOPLY #501 PREMIUM I #625 PARAGON MINERAL<br />

M4-FHC 4 #1000 ESHAVENT #500 PREMIUM #625 PARAGON MINERAL<br />

M4-FIC 4 #1000 ESHAVENT #506 SUPER 6 #625 PARAGON MINERAL<br />

M4-FBC 4 #1000 ESHAVENT #501 PREMIUM I #625 PARAGON MINERAL<br />

M4-FEC 4 #1000 ESHAVENT #605 PANOPLY #625 PARAGON MINERAL<br />

M5-BHC 5 #501 PREMIUM I #500 PREMIUM #625 PARAGON MINERAL<br />

M5-BIC 5 #501 PREMIUM I #506 SUPER 6 #625 PARAGON MINERAL<br />

M5-BBC 5 #501 PREMIUM I #501 PREMIUM I #625 PARAGON MINERAL<br />

M5-EBC 5 #605 PANOPLY #501 PREMIUM I #625 PARAGON MINERAL<br />

M5-FHC 5 #1000 ESHAVENT #500 PREMIUM #625 PARAGON MINERAL<br />

M5-FIC 5 #1000 ESHAVENT #506 SUPER 6 #625 PARAGON MINERAL<br />

M5-FBC 5 #1000 ESHAVENT #501 PREMIUM I #625 PARAGON MINERAL<br />

M2-CXD 2 #602 ARCTIC SHIELD #650 PANOPLY MINERAL<br />

M2-DXD 2 #603 SUPERBASE #650 PANOPLY MINERAL<br />

M2-EXD 2 #605 PANOPLY #650 PANOPLY MINERAL<br />

M3-BHD 3 #501 PREMIUM I #500 PREMIUM #650 PANOPLY MINERAL<br />

M3-BID 3 #501 PREMIUM I #506 SUPER 6 #650 PANOPLY MINERAL<br />

M3-BBD 3 #501 PREMIUM I #501 PREMIUM I #650 PANOPLY MINERAL<br />

M3-EHD 3 #605 PANOPLY #500 PREMIUM #650 PANOPLY MINERAL<br />

M3-EID 3 #605 PANOPLY #506 SUPER 6 #650 PANOPLY MINERAL<br />

M3-EBD 3 #605 PANOPLY #501 PREMIUM I #650 PANOPLY MINERAL<br />

M3-EED 3 #605 PANOPLY #605 PANOPLY #650 PANOPLY MINERAL<br />

M3-FHD 3 #1000 ESHAVENT #500 PREMIUM #650 PANOPLY MINERAL<br />

M3-FID 3 #1000 ESHAVENT #506 SUPER 6 #650 PANOPLY MINERAL<br />

M3-FBD 3 #1000 ESHAVENT #501 PREMIUM I #650 PANOPLY MINERAL<br />

M3-FED 3 #1000 ESHAVENT #605 PANOPLY #650 PANOPLY MINERAL<br />

M4-BHD 4 #501 PREMIUM I #500 PREMIUM #650 PANOPLY MINERAL<br />

M4-BID 4 #501 PREMIUM I #506 SUPER 6 #650 PANOPLY MINERAL<br />

M4-BBD 4 #501 PREMIUM I #501 PREMIUM I #650 PANOPLY MINERAL<br />

M4-EHD 4 #605 PANOPLY #500 PREMIUM #650 PANOPLY MINERAL<br />

M4-EID 4 #605 PANOPLY #506 SUPER 6 #650 PANOPLY MINERAL<br />

M4-EBD 4 #605 PANOPLY #501 PREMIUM I #650 PANOPLY MINERAL<br />

M4-FHD 4 #1000 ESHAVENT #500 PREMIUM #650 PANOPLY MINERAL<br />

M4-FID 4 #1000 ESHAVENT #506 SUPER 6 #650 PANOPLY MINERAL<br />

M4-FBD 4 #1000 ESHAVENT #501 PREMIUM I #650 PANOPLY MINERAL<br />

M4-FED 4 #1000 ESHAVENT #605 PANOPLY #650 PANOPLY MINERAL<br />

280


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

MALARKEY ROOFING COMPANY (continued)<br />

NEW / REPLACEMENT<br />

NON-NAILABLE (continued)<br />

M5-EHD 5 #605 PANOPLY #500 PREMIUM #650 PANOPLY MINERAL<br />

M5-EID 5 #605 PANOPLY #506 SUPER 6 #650 PANOPLY MINERAL<br />

M5-EBD 5 #605 PANOPLY #501 PREMIUM I #650 PANOPLY MINERAL<br />

M5-FHD 5 #1000 ESHAVENT #500 PREMIUM #650 PANOPLY MINERAL<br />

M5-FID 5 #1000 ESHAVENT #506 SUPER 6 #650 PANOPLY MINERAL<br />

M5-FBD 5 #1000 ESHAVENT #501 PREMIUM I #650 PANOPLY MINERAL<br />

F2-BXG 2 #501 PREMIUM I #1020 ESHALUM<br />

F2-EXG 2 #605 PANOPLY #1020 ESHALUM<br />

F3-BHG 3 #501 PREMIUM I #500 PREMIUM #1020 ESHALUM<br />

F3-BIG 3 #501 PREMIUM I #506 SUPER 6 #1020 ESHALUM<br />

F3-BBG 3 #501 PREMIUM I #501 PREMIUM I #1020 ESHALUM<br />

F3-EHG 3 #605 PANOPLY #500 PREMIUM #1020 ESHALUM<br />

F3-EIG 3 #605 PANOPLY #506 SUPER 6 #1020 ESHALUM<br />

F3-EBG 3 #605 PANOPLY #501 PREMIUM I #1020 ESHALUM<br />

NEW / REPLACEMENT See descritpion of the following specs under New / Replacement Non-Nailable<br />

NAILABLE<br />

M3-BBB M3-BCB M3-BDB<br />

M3-EHB M3-EIB M3-EBB<br />

M3-EEB M4-BHB M4-BIB<br />

M4-BBB M4-EEB M5-BHB<br />

M5-BIB M5-EHB M5-EIB<br />

M3-BHC M3-BIC M3-BBC<br />

M3-EHC M3-EIC M3-EBC<br />

M3-EEC M4-BHC M4-BIC<br />

M4-BBC M4-EHC M4-EIC<br />

M4-EBC M5-BHC M5-BIC<br />

M5-BBC M5-EBC M3-BHD<br />

M3-BID M3-BBD M3-EHD<br />

M3-EID M3-EBD M3-EED<br />

M4-BHD M4-BID M4-BBD<br />

M4-EHD M4-EID M4-EBD<br />

M5-EHD M5-EID M5-EBD<br />

F2-BXG F2-EXG F3-BHG<br />

F3-BIG F3-BBG F3-EHG<br />

F3-EIG<br />

F3-EBG<br />

N3-BHB<br />

N3-BIB<br />

NEW / REPLACEMENT See description of the following specs under New / Replacement Non-Nailable<br />

INSULATED<br />

M2-CXB M2-DXB M2-EXB<br />

M3-BHB MS-BIB M3-BBB<br />

M3-BCB M3-BDB M3-EHB<br />

M3-EIB M3-EBB M3-EEB<br />

M3-FHB M3-FIB M3-FBB<br />

M3-FEB M4-BHB M4-BIB<br />

M4-BBB M4-EBB M4-FEB<br />

M5-BHB M5-BIB M5-EIB<br />

M2-CXC M2-DXC M2-EXC<br />

M3-BHC M3-BIC M3-BBC<br />

M3-EHC M3-EIC M3-EBC<br />

M3-EEC M3-FHC M3-FIC<br />

M3-FBC M3-FCC M3-FDC<br />

M3-FEC M4-BHC M4-BIC<br />

M4-BBC M4-EHC M4-EIC<br />

M4-EBC M4-FHC M4-FIC<br />

M4-FBC M4-FEC M5-BHC<br />

M5-BIC M5-BBC M5-EBC<br />

M6-FHC M5-FIC M5-FBC<br />

M2-CXD M2-DXD M2-EXD<br />

M3-BHD M3-BID M3-BBD<br />

M3-EHD M3-EID M3-EBD<br />

M3-EED M3-FHD M3-FID<br />

M3-FBD M3-FED M4-BHD<br />

M4-BID M4-BBD M4-EHD<br />

M4-EID M4-EBD M4-FHD<br />

M4-FID M4-FBD M4-FED<br />

M5-EHD M5-EID M5-EBD<br />

M5-FHD M5-FID M5-FBD<br />

F3-BHG F3-BIG F3-BBG<br />

F3-EHG F3-EIG F3-EBG<br />

RECOVER See description of the following specs under New / Replacement Non-Nailable<br />

EXISTING ROOF<br />

M3-BBB<br />

M3-BCB<br />

M3-EHB M3-EIB M3-BDB<br />

M3-EEB M3-FHB M3-EBB<br />

M3-FBB M3-FEB M3-FIB<br />

M4-BIB M4-BBB M4-BHB<br />

281


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

RECOVER<br />

MALARKEY ROOFING COMPANY (continued)<br />

See description of the following specs under New / Replacement Non-Nailable<br />

EXISTING ROOF<br />

M4-FHB M4-FIB M4-EBB<br />

M4-FEB M5-BHB M4-FBB]<br />

M5-RHB M5-EIB M5-BIB<br />

M3-BIC M3-BBC M3-BHC<br />

M3-EIC M3-EBC M3-EHC<br />

M3-FHC M3-FIC N3-EEC<br />

M3-FCC M3-FDC M3-FBC<br />

M4-BHC M4-BIC M3-FEC<br />

M4-EHC M4-EIC M4-BBC<br />

M4-FHC M4-FIC M4-EBC<br />

M4-FEC M5-BHC M4-FBC<br />

M5-BBC M5-EBC M5-BIC<br />

M5-FIC M5-FBC M5-FHC<br />

M3-BID M3-BBD M3-BHD<br />

M3-EID M3-EBD M3-EHD<br />

M3-FHD M3-FID M3-EED<br />

M3-FED M4-BHD M3-FBD<br />

M4-BBD M4-EHD M4-BID<br />

M4-EBD M4-FHD M4-EID<br />

ME-FBD M4-FED M4-FID<br />

M5-EID M5-EBD M5-EHD<br />

M5-FID M5-FBD M5-FHD<br />

M4-BBE M4-EBE F3-BHG<br />

F3-BIG F3-BBG F3-EHG<br />

F3-EIG<br />

F3-EBG<br />

M3-BHB<br />

MS-BIB<br />

RECOVER<br />

EXISTING ROOF See description of the following specs under New / Replacement Non-Nailable<br />

INSULATED ADDED<br />

M2-CXB M3-FIE M3-BBB<br />

M3-BHB M2-DXB M3-EHB<br />

M3-BCB MS-BIB M3-EEB<br />

M3-EIB M3-BDB M3-FBB<br />

M3-FHB M3-EBB M4-BIB<br />

M3-FEB M3-FIB M4-EHB<br />

M4-BBB M4-BHB M5-EHB<br />

M5-BHB M4-EBB M2-DXC<br />

M5-BIB M5-EIB M3-BIC<br />

M2-EXC M2-CXC M3-EIC<br />

M3-BBC M3-BHC M3-FHC<br />

M3-EBC M3-EHC M3-FCC<br />

M3-FIC M3-EEC M4-BHC<br />

M3-FDC M3-FBC M4-EHC<br />

M4-BIC M3-FEC M4-FHC<br />

M4-EIC M4-BBC M4-FEC<br />

M4-FIC M4-EBC M5-BBC<br />

M5-BHC M4-FBC M5-FIC<br />

M5-EBC M5-BIC M2-DXD<br />

M5-FBC M5-FHC M3-BID<br />

M2-EXD M2-CXD M3-EID<br />

M3-BBD M3-BHD M3-FHD<br />

M3-EBD M3-EHD M3-FED<br />

M3-FID M3-EED M4-BBD<br />

M4-BHD M3-FBD M4-EBD<br />

M4-EHD M4-BID M4-FBD<br />

M4-FHD M4-EID M4-EID<br />

M4-FED M4-FID M5-FID<br />

M4-EBD M4-EHD F2-BXG<br />

M5-FBD M5-FHD F3-BIG<br />

F2-EXG F3-BHG F3-EIG<br />

F3-BBG<br />

F3-EHG<br />

F3-EBG<br />

M2-EXB<br />

Company Name<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

PERFORMANCE ROOF SYSTEMS, INC.<br />

NNC 2 APPROVED BASE SHEET BITUTAK MB OR MB MINERAL OPTIONAL OPTIONAL<br />

NEW /REPLACEMENT<br />

NAILABLE<br />

1N1X-() 2 GLASS FIBER DERBIGUM-XPS/DERBICOLOR-XPS<br />

1N1G-() 2 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP<br />

2N1X-() 3 GLASS FIBER DERBIGUM-XPS/DERBICOLOR-XPS<br />

282


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

NEW /REPLACEMENT<br />

PERFORMANCE ROOF SYSTEMS, INC. (continued)<br />

NAILABLE (continued)<br />

2N1G-() 3 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP<br />

3N1X-() 4 GLASS FIBER DERBIGUM-XPS/DERBICOLOR-XPS<br />

3N1G-() 4 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP<br />

1N2X-() 3 GLASS FIBER DERBIGUM-XPS/DERBICOLOR-XPS DERBIGUM-XPS/DERBICOLOR-XPS<br />

1N2G-() 3 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP DERBIGUM-GP/DERBICOLOR-GP<br />

2N2X-() 4 GLASS FIBER DERBIGUM-XPS/DERBICOLOR-XPS DERBIGUM-XPS/DERBICOLOR-XPS<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

2N2G-() 4 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP DERBIGUM-GP/DERBICOLOR-GP<br />

ND 2 APPROVED BASE SHEET BITUTAK MB OR MB MINERAL OPTIONAL OPTIONAL<br />

NEW / REPLACEMENT<br />

INSULATED<br />

1I1X-() 2 GLASS FIBER DERBIGUM-XPS/DERBICOLOR-XPS<br />

1I1G-() 2 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP<br />

2I1X-() 3 GLASS FIBER DERBIGUM-XPS/DERBICOLOR-XPS<br />

2I1G-() 3 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP<br />

3I1X-() 4 GLASS FIBER DERBIGUM-XPS/DERBICOLOR-XPS<br />

3I1G-() 4 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP<br />

1I2X-() 3 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP DERBIGUM-XPS/DERBICOLOR-XPS<br />

1I2G-() 3 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP DERBIGUM-GP/DERBICOLOR-GP<br />

2I2X-() 4 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP DERBIGUM-XPS/DERBICOLOR-XPS<br />

2I2G-() 4 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP DERBIGUM-GP/DERBICOLOR-GP<br />

0I2X-() 2 NONE DERBIGUM-XPS/DERBICOLOR-XPS<br />

0I2G-() 2 NONE DERBIGUM-GP/DERBICOLOR-GP<br />

INS 2 APPROVED BASE SHEET BITUTAK MB OR MB MINERAL OPTIONAL OPTIONAL<br />

RECOVER<br />

EXISTING ROOF<br />

1R1X-() 2 GLASS FIBER DERBIGUM-XPS/DERBICOLOR-XPS<br />

1R1G-() 2 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP<br />

2R1X-() 3 GLASS FIBER DERBIGUM-XPS/DERBICOLOR-XPS<br />

2R1G-() 3 GLASS FIBER DERBIGUM-GP/DERBICOLOR-GP<br />

RCV 2<br />

RECOVER<br />

EXISTING ROOF See New / Replacement Insulated<br />

INSULATION ADDED<br />

Company Name<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

POLYGLASS USA, INC.<br />

101PS 1 NONE POLYFLEX SMOOTH<br />

101PG 1 NONE POLYFLEX GRANULAR<br />

201PS 2 APPROVED POLYFLEX SMOOTH<br />

201PG 2 APPROVED POLYFLEX GRANULAR<br />

201PGFR 2 APPROVED POLYFLEX GRANULAR FR<br />

211DS/DG 2 APPROVED DUFLEX SMOOTH/GRANULAR<br />

211EST 2 APPROVED ELASTOSHIELD TS4<br />

311/DS/DG 3 APPROVED APPROVED DUFLEX SMOOTH/GRANULAR<br />

321EST 3 APPROVED APPROVED ELASTOSHIELD TS4<br />

341EFGSF 3 APPROVED APPROVED ELASTOFLEX G S6-FR<br />

341FVG 3 APPROVED APPROVED ELASTOFLEX VG<br />

341FVGF 3 APPROVED APPROVED ELASTOFLEX VG-FR<br />

391PS 3 APPROVED APPROVED POLYFLEX SMOOTH<br />

391PG 3 APPROVED APPROVED POLYFLEX GRANULAR<br />

391DS/DG 3 APPROVED APPROVED DUFLEX SMOOTH/GRANULAR<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

202PS 2 APPROVED POLYFLEX SMOOTH<br />

202PG 2 APPROVED POLYFLEX GRANULAR<br />

104IN 1 NONE INSULROOFING<br />

NEW / REPLACEMENT<br />

INSULATED<br />

103PS 1 NONE POLYFLEX SMOOTH<br />

103PG 1 NONE POLYFLEX GRANULAR<br />

203PS 2 APPROVED POLYFLEX SMOOTH<br />

203PG 2 APPROVED POLYFLEX GRANULAR<br />

203PGFR 2 APPROVED POLYFLEX GRANULAR FR<br />

204PS 2 APPROVED POLYFLEX SMOOTH<br />

204PG 2 APPROVED POLYFLEX GRANULAR<br />

283


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

NEW / REPLACEMENT<br />

POLYGLASS USA, INC. (continued)<br />

INSULATED (continued)<br />

204PGFR 2 APPROVED POLYFLEX GRANULAR FR<br />

213DS/DG 2 APPROVED DUFLEX SMOOTH/GRANULAR<br />

223EST 2 APPROVED ELASTOSHIELD TS4<br />

224EST 2 APPROVED ELASTOSHIELD TS4<br />

223PA/PR 2 APPROVED POLYALL OR POLYRAM<br />

303PGFR 3 APPROVED APPROVED POLYFLEX GRANULAR FR<br />

393PS/PG 3 APPROVED POLYFLEX SMOOTH/GRANULAR<br />

304PG/FR 3 APPROVED POLYFLEX GRANULAR FR<br />

NEW / REPLACEMENT<br />

INSULATED<br />

313DS/DG 3 APPROVED DUFLEX SMOOTH/GRANULAR<br />

343EFGS 3 APPROVED ELASTOFLEX GL-S6<br />

343EFVG 3 APPROVED ELASTOFLEX VG<br />

343EFVGF 3 APPROVED ELASTOFLEX VG-FR<br />

333PA/PR 3 APPROVED POLYALL OR POLYRAM<br />

RECOVER See New / Replacement, Nailable and Non-Nailable<br />

EXISTING ROOF<br />

RECOVER<br />

EXISTING ROOF<br />

INSULATION ADDED<br />

Company Name<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

See New / Replacement, Nailable and Non-Nailable<br />

SIPLAST INC<br />

2030CPH 3 PUNCHED GLASS BASE PARADIENE 20 PARADIENE 30<br />

2030CAA 3 PUNCHED GLASS BASE PARADIENE 20 PARADIENE 30<br />

4040CPT 3 PUNCHED GLASS BASE IREX VERAL<br />

5000CPH 2 PUNCHED GLASS BASE PARAFOR 50<br />

5000CAA 2 PUNCHED GLASS BASE PARAFOR 50<br />

5000CPT 2 PUNCHED GLASS BASE PARAFOR 50<br />

1035CPH 3 PUNCHED GLASS BASE PARATECH<br />

& PARABASE<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

2030PSH 3 PARAGLAS PARADIENE 20 PARADIENE 30<br />

2030WSH 3 PARAGLAS PARADIENE 20 PARADIENE 30<br />

2030CBH 3 PARABASE PARADIENE 20 PARADIENE 30<br />

2030PSA 3 PARAGLAS PARADIENE 20 PARADIENE 30<br />

2030WSA 3 PARAGLAS PARADIENE 20 PARADIENE 30<br />

2030CBA 3 PARABASE PARADIENE 20 PARADIENE<br />

5000PSA 2 PARAGLAS PARAFOR 50<br />

NEW / REPLACEMENT<br />

NAILABLE (contd)<br />

5000WSA 2 PARAGLAS PARAFOR 50<br />

5000CBA 2 PARABASE PARAFOR 50<br />

5000PIT 2 NONE IREX PARAFOR 50<br />

5000WIT 2 NONE IREX PARAFOR 50<br />

5000CBT 2 PARABASE PARAFOR 50<br />

3040PGH 2 PARABASE PARADIENE 40<br />

3040CGH 2 PARABASE PARADIENE 40<br />

1035CBH 3 PARABASE & PARAGLAS PARATECH<br />

NEW / REPLACEMENT<br />

INSULATED<br />

2030IH 2 NONE PARADIENE 20 PARADIENE 30<br />

2030IA 2 NONE PARADIENE 20 PARADIENE 30<br />

4040IT 2 NONE IREX VERAL<br />

5000IH 1 NONE PARAFOR 50<br />

5000IA 1 NONE PARAFOR 50<br />

5000IT 1 NONE PARAFOR 50<br />

1035IH 2 PARABASE PARATECH<br />

284


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

SIPLAST INC. (continued)<br />

RECOVER<br />

EXSITING ROOF<br />

INSULATION ADDED<br />

2030IH 2 NONE PARADIENE 20 PARADIENE 30<br />

2030IA 2 NONE PARADIENE 20 PARADIENE 30<br />

4040IT 2 NONE IREX VERAL<br />

5000IH 1 NONE PARAFOR 50<br />

5000IA 1 NONE PARAFOR 50<br />

5000IT 1 NONE PARAFOR 50<br />

1035IH 2 PARABASE PARATECH<br />

Company Name<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

SOUTHWESTERN PETROLEUM CORPORATION<br />

SYSTEM 302 1 UNI+SHIELD TRI-POLYMER<br />

SYSTEM 303 2 UNI+SHIELD II UNI+SHIELD II<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

SYSTEM 302 2 UNI+SHIELD TRI-POLYMER<br />

SYSTEM 303 3 UNI+SHIELD II UNI+SHIELD II<br />

NEW / REPLACEMENT<br />

INSULATED<br />

SYSTEM 302 2 UNI+SHIELD TRI-POLYMER<br />

SYSTEM 303 2 UNI+SHIELD II UNI+SHIELD II<br />

RECOVER<br />

EXSITING ROOF<br />

SYSTEM 302 2 UNI+SHIELD TRI-POLYMER<br />

SYSTEM 303 2 UNI+SHIELD II UNI+SHIELD II<br />

RECOVER<br />

EXSITING ROOF<br />

INSULATION ADDED<br />

SYSTEM 302 2 UNI+SHIELD TRI-POLYMER<br />

SYSTEM 303 2 UNI+SHIELD II UNI+SHIELD II<br />

Company Name<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

TAMKO ROOFING PRODUCTS INC.<br />

111 2 VAPOR CHAN AWAPLAN PREMIUM<br />

112 2 43 BASE/BASE-N-PLY AWAPLAN PREMIUM<br />

113 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAPLAN PREMIUM<br />

114 3 43 BASE/BASE-N-PLY GLASS PLY (NONMODIFIED) AWAPLAN PREMIUM<br />

111C 2 VAPOR CHAN AWAPLAN PREMIUM<br />

111HW 2 VAPOR CHAN AWAPLAN HEAT WELD<br />

112C 2 43 BASE/BASE-N-PLY AWAPLAN PREMIUM<br />

112HW 2 43 BASE/BASE-N-PLY AWAPLAN HEAT WELD<br />

113HW 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAPLAN HEAT WELD<br />

114HW 3 43 BASE/BASE-N-PLY GLASS PLY (NONMODIFIED) AWAPLAN HEAT WELD<br />

111FR 2 VAPOR CHAN AWAPLAN PREMIUM FR<br />

112FR 2 43 BASE/BASE-N-PLY AWAPLAN PREMIUM FR<br />

113FR 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAPLAN PREMIUM FR<br />

114FR 3 43 BASE/BASE-N-PLY GLASS PLY (NONMODIFIED) AWAPLAN PREMIUM FR<br />

211 2 VAPOR CHAN AWAPLAN 170<br />

212 2 43 BASE/BASE-N-PLY AWAPLAN 170<br />

213 3 VAPOR CHAN TAM-GLASS PREMIUM (NONMOD) AWAPLAN 170<br />

214 3 43 BASE/BASE-N-PLY TAM-GLASS PREMIUM (NONMOD) AWAPLAN 170<br />

211C 2 VAPOR CHAN AWAPLAN 170<br />

212C 2 43 BASE/BASE-N-PLY AWAPLAN 170<br />

211FR 2 VAPOR CHAN AWAPLAN 170 FR<br />

212FR 2 GLASS BASE AWAPLAN 170 FR<br />

745 3 43 BASE/BASE-N-PLY AWAPLAN VERSA SMOOTH VERSA CAP FR<br />

1013 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAFLEX<br />

1014 3 BASE-N-PLY GLASS PLY (NONMODIFIED) AWAFLEX<br />

1312 2 BASE-N-PLY AWAPLAN VERSA FLEX<br />

1013FR 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAFLEX FR<br />

1014FR 3 BASE-N-PLY GLASS PLY (NONMODIFIED) AWAFLEX FR<br />

285


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

NEW / REPLACEMENT<br />

INSULATED<br />

TAMKO ROOFING PRODUCTS INC. (continued)<br />

101 2 GLASS BASE AWAPLAN PREMIUM<br />

102 3 2 TAMKO PLY SHEETS AWAPLAN PREMIUM<br />

103 2 NONE AWAPLAN VERSA SMOOTH AWAPLAN PREMIUM<br />

104 2 NONE AWAPLAN VERSAFLEX AWAPLAN PREMIUM<br />

107 2 NONE VERSA BASE AWAPLAN PREMIUM<br />

108 4 3 TAMKO PLY SHEETS AWAPLAN PREMIUM<br />

109 3 NONE VERSA BASE TAM-GLASS PREMIUM (NONMOD) AWAPLAN PREMIUM<br />

101C 2 GLASS BASE AWAPLAN PREMIUM<br />

107C 2 NONE VERSA BASE AWAPLAN PREMIUM<br />

243 3 NONE AWAPLAN VERSA SMOOTH 2 TAMKO PLY SHEETS (NONMOD)<br />

201C 2 GLASS BASE AWAPLAN 170<br />

207C 2 NONE VERSA BASE AWAPLAN 170<br />

NEW / REPLACEMENT<br />

INSULATED (contd)<br />

101HW 2 GLASS BASE AWAPLAN HEAT WELDING<br />

102HW 3 2 TAMKO PLY SHEETS AWAPLAN HEAT WELDING<br />

103HW 2 NONE AWAPLAN VERSA SMOOTH AWAPLAN HEAT WELDING<br />

104HW 2 NONE AWAPLAN VERSAFLEX AWAPLAN HEAT WELDING<br />

107HW 2 NONE VERSA BASE AWAPLAN HEAT WELDING<br />

108HW 4 3 TAMKO PLY SHEETS AWAPLAN HEAT WELDING<br />

109HW 3 NONE VERSA BASE TAM-GLASS PREMIUM (NONMOD) AWAPLAN HEAT WELDING<br />

101FR 2 GLASS BASE AWAPLAN PREMIUM FR<br />

102FR 3 2 TAMKO PLY SHEETS AWAPLAN PREMIUM FR<br />

104FR 2 NONE AWAPLAN VERSAFLEX AWAPLAN PREMIUM FR<br />

107FR 2 NONE VERSA BASE AWAPLAN PREMIUM FR<br />

108FR 4 3 TAMKO PLY SHEETS AWAPLAN PREMIUM FR<br />

109FR 3 NONE VERSA BASE TAM-GLASS PREMIUM (NONMOD) AWAPLAN PREMIUM FR<br />

201 2 GLASS BASE AWAPLAN 170<br />

203 2 NONE AWAPLAN VERSA SMOOTH AWAPLAN 170<br />

202 3 2 TAMKO PLY SHEETS AWAPLAN 170<br />

204 2 AWAPLAN VERSA FLEX AWAPLAN 170<br />

207 2 NONE VERSA BASE AWAPLAN 170<br />

208 4 3 TAMKO PLY SHEETS AWAPLAN 170<br />

209 3 NONE TAM-GLASS PREMIUM (NONMOD) VERSA BASE AWAPLAN 170<br />

201FR 2 GLASS BASE AWAPLAN 170 FR<br />

203FR 2 NONE AWAPLAN VERSA SMOOTH AWAPLAN 170 FR<br />

204FR 2 AWAPLAN VERSA FLEX AWAPLAN 170 FR<br />

207FR 2 NONE VERSA BASE AWAPLAN 170 FR<br />

208FR 4 3 TAMKO PLY SHEETS AWAPLAN 170 FR<br />

209FR 3 NONE TAM-GLASS PREMIUM (NONMOD) VERSA BASE AWAPLAN 170 FR<br />

244 2 NONE AWAPLAN VERSA-SMOOTH TAM-CAP<br />

701 2 NONE VERSA BASE VERSA CAP FR<br />

744 2 GLASS BASE (OPTIONAL) AWAPLAN VERSA SMOOTH VERSA CAP FR<br />

703 3 NONE 2 PLIES VERSA BASE VERSA CAP FR<br />

704 3 2 PLIES TAM-PLY IV VERSA CAP FR<br />

705 4 3 PLIES TAM-PLY IV VERSA CAP FR<br />

706 5 4 PLIES TAM-PLY IV VERSA CAP FR<br />

1001 2 BASE-N-PLY AWAFLEX<br />

1002 3 2 TAMKO PLY SHEETS AWAFLEX<br />

1004 2 NONE AWAPLAN VERSAFLEX AWAFLEX<br />

1007 2 NONE VERSA-BASE AWAFLEX<br />

103FR 2 NONE AWAPLAN VERSA SMOOTH AWAPLAN PREMIUM FR<br />

203FR 2 NONE AWAPLAN VERSA SMOOTH AWAPLAN 170 FR<br />

1001 FR 2 BASE-N-PLY AWAFLEX FR<br />

1002 FR 3 2 TAMKO PLY SHEETS AWAFLEX FR<br />

1004 FR 2 NONE AWAPLAN VERSAFLEX AWAFLEX FR<br />

1007 FR 2 NONE VERSA-FLEX AWAFLEX FR<br />

1304 2 AWAPLAN VERSA FLEX AWAPLAN VERSA FLEX<br />

1343 3 AWAPLAN VERSA FLEX 2 TAMKO PLY SHEETS<br />

RECOVER<br />

EXISTING ROOF<br />

135 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAPLAN PREMIUM<br />

136 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAPLAN PREMIUM<br />

135HW 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAPLAN HEAT WELDING<br />

136HW 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAPLAN HEAT WELDING<br />

135FR 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAPLAN PREMIUM FR<br />

136FR 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAPLAN PREMIUM FR<br />

235 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAPLAN 170<br />

236 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAPLAN 170<br />

235FR 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAPLAN 170 FR<br />

286


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

Company Name<br />

TAMKO ROOFING PRODUCTS INC. (continued)<br />

RECOVER<br />

EXISTING ROOF<br />

236FR 3 VAPOR CHAN GLASS PLY (NONMODIFIED) AWAPLAN 170 FR<br />

RECOVER<br />

EXISTING ROOF See New / Replacement, Insulated<br />

INSULATION ADDED<br />

Company Name<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

TEXAS REFINERY CORP.<br />

N-101 3 TYPE II GLASBASE MIGHTYPLATE MIGHTYPLATE<br />

N-102 3 APPROVED MIGHTYPLATE MIGHTYPLATE<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

N-301 3 TYPE II GLASBASE MIGHTYPLATE MIGHTYPLATE<br />

N-302 3 APPROVED MIGHTYPLATE MIGHTYPLATE<br />

NEW / REPLACEMENT<br />

INSULATED<br />

N-201 3 TYPE II GLASBASE MIGHTYPLATE MIGHTYPLATE<br />

N-202 3 APPROVED MIGHTYPLATE MIGHTYPLATE<br />

N-203 2 NONE MIGHTYPLATE MIGHTYPLATE<br />

RECOVER<br />

EXISTING ROOF<br />

E-401 1 NONE MIGHTYPLATE<br />

RECOVER<br />

EXISTING ROOF<br />

INSULATION ADDED<br />

E-501 1 NONE MIGHTYPLATE<br />

E-502 2 TYPE II GLASBASE MIGHTYPLATE<br />

E-503 2 APPROVED MIGHTYPLATE<br />

COMPANY NAME<br />

NEW / REPLACEMENT<br />

NON-NAILABLE<br />

NEW / REPLACEMENT<br />

NAILABLE<br />

NEW / REPLACEMENT<br />

INSULATED<br />

TEXSA, S.A.<br />

1 - HIPER M.P.<br />

1 - MIN TEXAL -15 FP-S<br />

2 - TEXAL FV 3MM TEXAL -15 FP-S 4MM<br />

1 - TEXAL -15 FP-S 4MM<br />

1 - MIN MOFLEX -20 FP-S<br />

2 - TEXAL FV 3MM MIN MOFLEX -20 FP-S<br />

1 - M.P. PARKING<br />

1 MINERAL M.P. 5KG FM<br />

2 TEXAL FV 3MM TEXAL -15 FP-S 4MM<br />

2 HIPER M.P. TEXAL PY MIN<br />

2 TEXAL FV 3MM MIN MOFLEX -20 FP-S<br />

COMPANY NAME<br />

U.S. INTEC, INC.<br />

New / Replacement<br />

Non-Nailable<br />

LCSP-1-C 1 BRAI SUPREME APP SMOOTH<br />

GB-1-C 1 BRAI SUPREME APP GRANULE<br />

GBFR-1-C 1 BRAI SUPREME APP GRANULE FR<br />

GB-2-FC-C 2 WORKHORSE APP SMOOTH BRAI SUPREME APP GRANULE<br />

GBFR-2FC-C 2 WORKHORSE APP SMOOTH BRAI SUPREME APP GRANULE FR<br />

GB-2SP-C 2 BRAI SUPREME APP SMOOTH BRAI SUPREME APP GRANULE<br />

GBFR-2SP-C 2 BRAI SUPREME APP SMOOTH BRAI SUPREME APP GRANULE FR<br />

GB-P3SP-LWC 3 SUPREME ELIMINATOR BRAI SUPREME APP SMOOTH BRAI SUPREME APP GRANULE<br />

GBFR-P3SP-LWC 3 SUPREME ELIMINATOR BRAI SUPREME APP SMOOTH BRAI SUPREME APP GRANULE FR<br />

BF 190-P3MPB-LWC 3 SUPREME ELIMINATOR BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GRANULE<br />

BF 190FR-P3MBP-LWC 3 SUPREME ELIMINATOR BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS POLY GRANULE FR<br />

BF 250 FR-P3MPB-LWC 3 SUPREME ELIMINATOR BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

287


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

COMPANY NAME<br />

U.S. INTEC, INC. (continued)<br />

BF4.5FR-P3MPB-LWC 3 SUPREME ELIMINATOR BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GLASS FIBER FR<br />

New / Replacement<br />

Non-Nailable<br />

(continued)<br />

G-BFS-P3MBP-LWC 3 SUPREME ELIMINATOR BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS POLY SMOOTH<br />

BF190-P4TP-LWC 4 SUPREME ELIMINATOR & GAFGLAS PLY 4 BRAI SUPREME SBS GRANULE<br />

BF190-FR-P4TP-LWC 4 SUPREME ELIMINATOR & GAFGLAS PLY 4 BRAI SUPREME SBS POLY GRANULE FR<br />

BF250FR-P4TP-LWC 4 SUPREME ELIMINATOR & GAFGLAS PLY 4 BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF4.5FR-P4TP-LWC 4 SUPREME ELIMINATOR & GAFGLAS PLY 4 BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-P4TP-LWC 4 SUPREME ELIMINATOR & GAFGLAS PLY 4 BRAI SUPREME SBS POLY SMOOTH<br />

GB-P3SP-LWS 3 SUPREME ELIMINATOR BRAI SUPREME APP SMOOTH BRAI SUPREME APP GRANULE<br />

GBFR-P3SP-LWC 3 SUPREME ELIMINATOR BRAI SUPREME APP SMOOTH BRAI SUPREME APP GRANULE FR<br />

BF 190-P3BS-LWC 3 SUPREME ELIMINATOR BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME SBS GRANULE<br />

BF 190FR-P3BFS-LWC 3 SUPREME ELIMINATOR BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME SBS POLY GRANULE FR<br />

BF 250 FR-P3BFS-LWC 3 SUPREME ELIMINATOR BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME SBS GLASS FIBER FR<br />

BF4.5FR-P3BFS-LWC 3 SUPREME ELIMINATOR BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME SBS POLY SMOOTH<br />

G-BFS-P3BFS-LWC 3 SUPREME ELIMINATOR BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME GLASS SMOOTH BRAI SUPREME SBS GRANULE<br />

BF 190-P4UP-LWC 4 SUP. ELIM & 2 GAFGLAS FLEX PLY 6 BRAI SUPREME SBS GRANULE BRAI SUPREME GLASS SMOOTH BRAI SUPREME SBS POLY GRANULE FR<br />

BF190FR-PRUP-LWC 4 SUP. ELIM & 2 GAFGLAS FLEX PLY 6 BRAI SUPREME SBS POLY GRANULE FR BRAI SUPREME GLASS SMOOTH BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF250FR-PRUP-LWC 4 SUP. ELIM & 2 GAFGLAS FLEX PLY 6 BRAI SUPREME PLUS SBS POLY GRANULE FR BRAI SUPREME GLASS SMOOTH BRAI SUPREME SBS GLASS GRANULE FR<br />

BF4.5FR-P4UP-LW C 4 SUP. ELIM & 2 GAFGLAS FLEX PLY 6 BRAI SUPREME SBS GLASS GRANULE FR BRAI SUPREME GLASS SMOOTH BRAI SUPREME SBS POLY SMOOTH<br />

BF190-P4MBP-LWC 4 SUPREME ELIMINATOR BRAI SUPREME SBS GLASS SMOOTH<br />

BF190FR-PR4MPB-LWC 4 SUPREME ELIMINATOR BRAI SUPREME SBS GLASS SMOOTH<br />

BR250FR-P4MBP-LWC 4 SUPREME ELIMINATOR BRAI SUPREME SBS GLASS SMOOTH<br />

BF4.5R-P4MBP-LWC 4 SUPREME ELIMINATOR BRAI SUPREME SBS GLASS SMOOTH<br />

G-BFS-P4MBP-LWC 4 SUPREME ELIMINATOR BRAI SUPREME SBS GLASS SMOOTH<br />

BF190-P5UP-LWC 5 SUP. ELIM & 3 GAFGLAS FLEX PLY 6 BRAI SUPREME SBS GRANULE<br />

BF190FR-P5UP-LWC 5 SUP. ELIM & 3 GAFGLAS FLEX PLY 6 BRAI SUPREME SBS POLY GRANULE FR<br />

BF250FR-5UP-LWC 5 SUP. ELIM & 3 GAFGLAS FLEX PLY 6 BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF4.5FR-P5UP-LWC 5 SUP. ELIM & 3 GAFGLAS FLEX PLY 6 BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-P5UP-LWC 5 SUP. ELIM & 3 GAFGLAS FLEX PLY 6 BRAI SUPREME SBS POLY SMOOTH<br />

New / Replacement<br />

Nailable<br />

LCSP-2B-N 2 WORKHORSE ULTRA BASE BRAI SUPREME APP SMOOTH<br />

GB-2B-N 2 WORKHORSE ULTRA BASE BRAI SUPREME APP GRANULE<br />

GBFR-2B-N 2 WORKHORSE ULTRA BASE BRAI SUPREME APP GRANULE FR<br />

BF4.5FR-2B-N 2 WORKHORSE ULTRA BASEBRAI SUPREME SBS GLASS GRANULE FR<br />

BF190-2B-N 2 WORKHORSE ULTRA BASE BRAI SUPREME SBS GRANULE<br />

BF190-FR-2B-N 2 WORKHORSE ULTRA BASE BRAI SUPREME SBS POLY GRANULE FR<br />

BF250FR-2B-N 2 WORKHORSE ULTRA BASE BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-2B-N 2 WORKHORSE ULTRA BASE BRAI SUPREME SBS POLY SMOOTH<br />

BF190-B3TP-N 3 WORKHORSE ULTRA BASE & GAFGLAS PLY 4 BRAI SUPREME SBS GRANULE<br />

BF190FR-B3TP-N 3 WORKHORSE ULTRA BASE & GAFGLAS PLY 4 BRAI SUPREME SBS POLY GRANULE FR<br />

BF4.5FR-B3TP-N 3 WORKHORSE ULTRA BASE & GAFGLAS PLY 4<br />

G-BFS-B3TP-N 3 WORKHORSE ULTRA BASE & GAFGLAS PLY 4 BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

GB-B3FC-N 3 WORKHORSE ULTRA BASE & GAFGLAS PLY 4 BRAI SUPREME SBS GLASS GRANULE FR<br />

GBFR-B4DC-N 3 WORKHORSE ULTRA BASE WORKHORSE APP SMOOTH BRAI SUPREME APP GRANULE<br />

BF190-B3MBP-N 3 WORKHORSE ULTRA BASE WORKHORSE APP SMOOTH BRAI SUPREME APP GRANULE FR<br />

BF190FR-B3MP-N 3 WORKHORSE ULTRA BASE BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GRANULE<br />

BF250FR-B3MBP-N 3 WORKHORSE ULTRA BASE BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS POLY GRANULE FR<br />

BF4.4FR-B3MBP-N 3 WORKHORSE ULTRA BASE BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

G-BFS-B3MBP-N 3 WORKHORSE ULTRA BASE BRAI SUPREME APP GRANULE BRAI SUPREME SBS GLASS GRANULE FR<br />

GB-B4TP-N 3 WORKHORSE ULTRA BASE BRAI SUPREME APP GRANULE FR BRAI SUPREME SBS POLY SMOOTH<br />

GBFR-B4TP-N 4 WORKHORSE UB & 2 GAFGLAS PLY 4 BRAI SUPREME SBS GRANULE<br />

BF190-B4TPN-N 4 WORKHORSE UB & 2 GAFGLAS PLY 4 BRAI SUPREME SBS POLY GRANULE FR<br />

BF190FR-B4TP-N 4 WORKHORSE UB & 2 GAFGLAS PLY 4 BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF250FR-B4TP-N 4 WORKHORSE UB & 2 GAFGLAS PLY 4 BRAI SUPREME SBS GLASS GRANULE FR<br />

BF4.5FR-B4TP-N 4 WORKHORSE UB & 2 GAFGLAS PLY 4 BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-B4TP-N 4 WORKHORSE UB & 2 GAFGLAS PLY 4 BRAI SUPREME SBS POLY SMOOTH<br />

GB-B3SP-N 3 WORKHORSE ULTRA BASE BRAI SUPREME APP SMOOTH BRAI SUPREME APP GRANULE<br />

GBFR-B3SP-N 3 WORKHORSE ULTRA BASE BRAI SUPREME APP SMOOTH BRAI SUPREME APP GRANULE<br />

BF190-BSBFS-N 3 WORKHORSE ULTRA BASE BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME SBS GRANULE<br />

BF190FR-BSBFS-N 3 WORKHORSE ULTRA BASE BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME SBS POLY GRANULE FR<br />

BF250FR-B3BFS-N 3 WORKHORSE ULTRA BASE BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF4.5FR-BSBFS-N 3 WORKHORSE ULTRA BASE BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-BEBFS-N 3 WORKHORSE ULTRA BASE BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME SBS POLY SMOOTH<br />

BF190-B4UP-N 4 WORKHORSE ULTRA BASE & 2 GAFLAS FLEXPLY 6 BRAI SUPREME SBS GRANULE<br />

BF190FR-B4UP-N 4 WORKHORSE ULTRA BASE & 2 GAFLAS FLEXPLY 6 BRAI SUPREME SBS POLY GRANULE FR<br />

BF250FR-B4UP-N 4 WORKHORSE ULTRA BASE & 2 GAFLAS FLEXPLY 6 BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF4.RFR-B4UP-N 4 WORKHORSE ULTRA BASE & 2 GAFLAS FLEXPLY 6 BRAI SUPREME SBS GLASS GRANULE FR<br />

BF190-B4MBP-N 4 WORKHORSE ULTRA BASE BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GRANULE<br />

BF190FR-B4MBP-N 4 WORKHORSE ULTRA BASE BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS POLY GRANULE FR<br />

BF250FR-BRMBP-N 4 WORKHORSE ULTRA BASE BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF4.RFR-B4MBP-N 4 WORKHORSE ULTRA BASE BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-BRMBP-N 4 WORKHORSE ULTRA BASE BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS POLY SMOOTH<br />

288


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

COMPANY NAME<br />

U.S. INTEC, INC. (continued)<br />

BF190-B5UP-N 5 WORKHORSE ULTRA BASE & 3 GAFLGAS FLEXPLY 6 BRAI SUPREME SBS GRANULE<br />

BF190FR=B5UP-N 5 WORKHORSE ULTRA BASE & 3 GAFLGAS FLEXPLY 6 BRAI SUPREME SBS POLY GRANULE FR<br />

BF250FR-B5UP-N 5 WORKHORSE ULTRA BASE & 3 GAFLGAS FLEXPLY 6 BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF4.5FR-B5UP-N 5 WORKHORSE ULTRA BASE & 3 GAFLGAS FLEXPLY 6 BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-B5UP-N 5 WORKHORSE ULTRA BASE & 3 GAFLGAS FLEXPLY 6 BRAI SUPREME SBS POLY SMOOTH<br />

BF4.5FR--3TP-LWC 3 SUP ELIM AND GAFGLAS PLY 4 BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-P3TP-LWC 3 SUP ELIM AND GAFGLAS PLY 4 BRAI SUPREME SBS POLY SMOOTH<br />

New / Replacement<br />

Insulated<br />

LCSP-WB-RI 2 WORKHORSE ULTRA BASE BRAI SUPREME APP SMOOTH<br />

GB-2B-RI 2 WORKHORSE ULTRA BASE BRAI SUPREME APP GRANULE<br />

GBFR-2B-RI 2 WORKHORSE ULTRA BASE BRAI SUPREME APP GRANULE FR<br />

BF4.5FR-2B-RI 2 WORKHORSE ULTRA BASEBRAI SUPREME SBS GLASS GRANULE FR<br />

BF190-2B-RI 2 WORKHORSE ULTRA BASE BRAI SUPREME SBS GRANULE<br />

BF190FR-2B-RI 2 WORKHORSE ULTRA BASE BRAI SUPREME SBS POLY GRANULE FR<br />

BF250FR-2B-RI 2 WORKHORSE ULTRA BASE BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-2B-RI 2 WORKHORSE ULTRA BASE BRAI SUPREME SBS POLY SMOOTH<br />

LCSP-3TP-RI 3 2 GAFGLAS PLY 4 BRAI SUPREME APP SMOOTH<br />

BF190-BSTP-RI 3 WORKHORSE ULTRA BASE & GAFGLAS PLY 4 BRAI SUPREME SBS GRANULE<br />

BF190FR-B3TP-RI 3 WORKHORSE ULTRA BASE & GAFGLAS PLY 4 BRAI SUPREME SBS POLY GRANULE FR<br />

BF250FR-2BFS-RI 3 WORKHORSE ULTRA BASE & GAFGLAS PLY 4 BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF4.5FR-2BFS-RI 3 WORKHORSE ULTRA BASE & GAFGLAS PLY 4 BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-B3TP-RI 3 WORKHORSE ULTRA BASE & GAFGLAS PLY 4 BRAI SUPREME SBS POLY SMOOTH<br />

BF190-2BFS-RI 2 BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME SBS GRANULE<br />

BF190FR-2BFS-RI 2 BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME SBS POLY GRANULE FR<br />

BF250FR-WBFS-RI 2 BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF4.5FR-WBFS-RI 2 BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-WBFS-RI 2 BRAI SUPREME SBS POLY SMOOTH BRAI SUPREME SBS POLY SMOOTH<br />

GB-B3SP-RI 3 WORKHORSE ULTRA BASE BRAI SUPREME APP SMOOTH<br />

GBFFR-B3SP-RI 3 WORKHORSE ULTRA BASE BRAI SUPREME APP SMOOTH<br />

BF190-3MBP-RI 3 BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GRANULE<br />

BF190FR-3MBP-RI 3 BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS POLY GRANULE FR<br />

BF2R0FR-3MBP-RI 3 BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF4.5FR-3MBP-RI 3 BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-3MBP-RI 3 BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS POLY SMOOTH<br />

BF190-WMBP-RI 2 BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS GRANULE<br />

BF190FR-2MBP-RI 2 BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS POLY GRANULE FR<br />

BF250FR-2MBP-RI 2 BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS POLY GRANULE FR<br />

BF4.5FR-2MBP-RI 2 BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS POLY GRANULE FR<br />

G-BFS-WMBP-RI 2 BRAI SUPREME SBS GLASS SMOOTH BRAI SUPREME SBS POLY SMOOTH<br />

GB-B3FC-RI 3 WORKHOURSE ULTRA BASE WORKHORSE APP SMOOTH BRAI SUPREME APP GRANULE<br />

GBFR-B3FC-RI 3 WORKHOURSE ULTRA BASE WORKHORSE APP SMOOTH BRAI SUPREME APP GRANULE FR<br />

GB-B3SP-RI 3 WORKHOURSE ULTRA BASE BRAI SUPREME APP SMOOTH BRAI SUPREME APP GRANULE<br />

GBFR-B3SP-RI 3 WORKHOURSE ULTRA BASE BRAI SUPREME APP SMOOTH BRAI SUPREME APP GRANULE FR<br />

GB-3TP-RI 3 2 GAFGLAS PLY 4 BRAI SUPREME APP GRANULE<br />

GBFR-3TP-RI 3 2 GAFGLAS PLY 4 BRAI SUPREME APP GRANULE FR<br />

GB-3UP-RI 3 2 GAFGLAS PLY 4 BRAI SUPREME APP GRANULE<br />

GBFR-3UP-RI 3 2 GAFGLAS PLY 4 BRAI SUPREME APP GRANULE FR<br />

GB-B3TP-RI 3 WORKHORSE ULTRA BASE & GAFGLAS PLY 4 BRAI SUPREME APP GRANULE<br />

GBFR-B3TP-RI 3 WORKHORSE ULTRA BASE & GAFGLAS PLY 4 BRAI SUPREME APP GRANULE FR<br />

BF190-3TP-RI 3 2 GAFGLAS PLY 4 BRAI SUPREME SBS GRANULE<br />

BF180FR-3TP-RI 3 2 GAFGLAS PLY 4 BRAI SUPREME SBS POLY GRANULE FR<br />

BF250FR-3TP-RI 3 2 GAFGLAS PLY 4 BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF4.5-3TP-RI 3 2 GAFGLAS PLY 4 BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-3TP-RI 3 2 GAFGLAS PLY 4 BRAI SUPREME SBS POLY SMOOTH<br />

GB-4TP-RI 4 3 GAFGLAS PLY 4 BRAI SUPREME APP GRANULE<br />

GBFR-4TP-RI 4 3 GAFGLAS PLY 4 BRAI SUPREME APP GRANULE FR<br />

BF190-MBP3UP-RI 3 SBS GLASS SMOOTH & GAFGLAS FLEXYPLY 6 BRAI SUPREME SBS GRANULE<br />

BF190FR-MBP3UP-RI 3 SBS GLASS SMOOTH & GAFGLAS FLEXYPLY 6 BRAI SUPREME SBS GRANULE FR<br />

BF250FR-MBP3UP-RI 3 SBS GLASS SMOOTH & GAFGLAS FLEXYPLY 6 BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF4.5FR-MBP3UP-RI 3 SBS GLASS SMOOTH & GAFGLAS FLEXYPLY 6 BRAI SUPREME SBS GLASS GRANULE FR<br />

GB-4UP-IR 4 3 GAFGLAS FLEXPLY 6 BRAI SUPREME APP GRANULE<br />

GBFR-4UP-IR 4 3 GAFGLAS FLEXPLY 6 BRAI SUPREME APP GRANULE FR<br />

BF190-4UP-RI 4 3 GAFGLAS FLEXPLY 6 BRAI SUPREME SBS GRANULE<br />

BF-190FR-UP-RI 4 3 GAFGLAS FLEXPLY 6 BRAI SUPREME SBS GRANULE FR<br />

BF250FR-4UP-RI 4 3 GAFGLAS FLEXPLY 6 BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

BF4.5FR-4UP-RI 4 3 GAFGLAS FLEXPLY 6 BRAI SUPREME SBS GLASS GRANULE FR<br />

G-BFS-4UP-RI 4 3 GAFGLAS FLEXPLY 6 BRAI SUPREME SBS POLY SMOOTH<br />

Recover<br />

Existing <strong>Roof</strong><br />

LCSP-1RC 1 BRAI SUPREME APP SMOOTH<br />

GB-1-RC 1 BRAI SUPREME APP GRANULE<br />

GBFR-1-RC 1 BRAI SUPREME APP GRANULE FR<br />

LCSB-2B-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME APP SMOOTH<br />

289


Modified Bitumen Part 3: Modified Bitumen Specifications<br />

TYPE OF ROOF<br />

INSTALLATION &<br />

SUBSTRATE<br />

MANUFACTURER'S<br />

SPECIFICATION NO.<br />

TOTAL<br />

NUMBER OF<br />

PLIES IN<br />

MEMBRANE<br />

ASSEMBLY<br />

BASE SHEET<br />

DESCRIPTION<br />

IF OTHER THAN<br />

MODIFIED<br />

BITUMEN SHEET<br />

NAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANE<br />

FIRST SHEET SECOND SHEET THIRD SHEET<br />

COMPANY NAME<br />

U.S. INTEC, INC. (continued)<br />

GB-2B-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME APP GRANULE<br />

GBFR-2B-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME APP GRANULE FR<br />

BF4.5FR-WB-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME SBS GLASS GRANULE FR<br />

BF190-2B-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME SBS GRANULE<br />

BF190FR-2B-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME SBS POLY GRANULE FR<br />

BF250FR-2BPRC 2 WORKHOURSE ULTRA BASE BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

G-BFS-2B-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME SBS POLY SMOOTH<br />

Recover Existing <strong>Roof</strong><br />

Insulation Added<br />

LCSP-2B-RI-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME APP SMOOTH<br />

GB-2B-RI-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME APP GRANULE<br />

GBFR-2B-RI-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME APP GRANULE FR<br />

BF4.5FR-2B-RI-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME SBS GLASS GRANULE FR<br />

BF190-2B-RI-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME SBS GRANULE<br />

BF190FR-2B-RI-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME SBS POLY GRANULE FR<br />

BF20FR-2B-RI-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME PLUS SBS POLY GRANULE FR<br />

G-BFS-2B-RI-RC 2 WORKHOURSE ULTRA BASE BRAI SUPREME SBS POLY SMOOTH<br />

290


PVC Part 1: General Information<br />

1. COMPANY NAME FIRESTONE FIRESTONE FLEX FLEX GAF<br />

BUILDING BUILDING MEMBRANE MEMBRANE MATERIALS<br />

PRODUCTS PRODUCTS INTERNATIONAL INTERNATIONAL CORP.<br />

2. PRODUCT NAME ULTRAPLY ULTRAPLY FLEX FLEX EVERGUARD<br />

0.45 0.6 MF/F 50 MF/R 60 EGSR-40<br />

3. PRODUCT DESCRIPTION<br />

Reinforcement POLYESTER POLYESTER REINF POLY. REINF POLY. POLYESTER<br />

Colors WHITE WHITE WHITE /<br />

OFF WHITE<br />

WHITE /<br />

OFF WHITE<br />

WHITE / GRAY /<br />

CUSTOM<br />

Installed Weight (lbs./ft 2 w/o ballast) 0.26 NOM 0.35 NOM 0.35 0.45 0.26<br />

4. COATING REQUIRED NONE NONE NONE NONE NONE<br />

5. USE IN:<br />

New <strong>Roof</strong>ing X X X X X<br />

Reroofing X X X X X<br />

6. FIELD LAP JOINT METHOD HEAT WELD HEAT WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD<br />

7. TYPES OF ROOF SYSTEMS<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 ) 10 LBS. 10 LBS. 10 MIN. 10 MIN. 10<br />

Partially Adhered (method) MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST.<br />

Fully Adhered (method) CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. ADHESIVE<br />

Protected <strong>Roof</strong> Membrane Assembly X X X<br />

8. MINIMUM SLOPE REQUIRED POSITIVE DRAIN POSITIVE DRAIN DEAD LEVEL DEAD LEVEL PER CODE<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber O O S O S O<br />

Mineral Fiber O O S O S O<br />

Polystyrene O O S O S O X O<br />

Cellular Glass O O S O S O<br />

Phenolic<br />

Fiberboard X X X X X<br />

Perlite X O X O X O X O<br />

Polyisocyanurate X X X X X<br />

Polyurethane O O X<br />

Gypsum O O X O X O O S<br />

Concrete O O S O S O O S<br />

Wood Plank O O S O S O O S<br />

Plywood O O X O X S O S<br />

Existing Built-Up Membrane O O S O S O O S<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 0 – 120 0 – 120 0 – 120 0 – 120 0 -120<br />

12. FLASHING MATERIAL ULTRAPLY ULTRAPLY ROOF ROOF REINFORCED<br />

CTD / METAL / CTD / METAL / MEMBRANE / MEMBRANE / MEMBRANE<br />

REINFORCED REINFOCED CTD METAL CTD METAL COATED METAL<br />

MEMBRANE<br />

MEMBRANE<br />

13. FLASHING METHOD HEAT WELD HEAT WELD HEAT WELD HEAT WELD HOT AIR WELD<br />

OR OR AND<br />

ADHESIVE ADHESIVE ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA<br />

Manufacture USA USA USA USA USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1992<br />

Within USA 1986 1994 1988 1988 1988<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA THOUSANDS THOUSANDS<br />

Within USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS, DIRECT DISTRS, DIRECT DIRECT DIRECT DIST/DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 5 5 4 4 4<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: Paul Oliveira Paul Oliveira J. DOYLE J. DOYLE REGIONAL<br />

317/575-7186 317/575-7186 610/286–7788 610/286–7788 OFFICE<br />

22. TECHNICAL INFORMATION, CONTACT: Jeff Henegar Jeff Henegar M GIANGIACOMO M GIANGIACOMO TECHNICAL<br />

23. SEE APPENDIX IF CHECKED<br />

317/575-7028 317/575-7028 610/286–7788 610/286–7788 SERVICES<br />

292


PVC Part 1: General Information<br />

GAF GAF GAF GAF GAF GAF GAF GAF GAF GENFLEX<br />

MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS ROOFING<br />

CORP. CORP. CORP. CORP. CORP. CORP. CORP. CORP. CORP. SYSTEMS<br />

EVERGUARD EVERGUARD EVERGUARD EVERGUARD EVERGUARD EVERGUARD EVERGUARD EVERGUARD EVERGUARD GENFLEX<br />

EGSR-45 EGSR-50 EGSR-60 EGSR-80 EGFB-40 EGFB-45 EGFB-50 EGFB-60 EGFB-80 RM.048<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLY/FLEECE BK POLY/FLEECE BK POLY/FLEECE BK POLY/FLEECE BK POLY/FLEECE BK POLYESTER<br />

WHITE / GRAY /<br />

CUSTOM<br />

WHITE / GRAY /<br />

CUSTOM<br />

WHITE / GRAY /<br />

CUSTOM<br />

WHITE / GRAY /<br />

CUSTOM<br />

WHITE / GRAY /<br />

CUSTOM<br />

WHITE / GRAY /<br />

CUSTOM<br />

WHITE / GRAY /<br />

CUSTOM<br />

WHITE / GRAY /<br />

CUSTOM<br />

WHITE / GRAY /<br />

CUSTOM<br />

WHITE / GRAY /<br />

TAN<br />

0.29 0.32 0.38 0.51 0.30 0.33 0.36 0.43 0.55 0.30<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD<br />

10 10 10 10 10 10 10 10 10<br />

MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST MECH. FAST MECH. FAST. MECH. FAST. MECH. FAST.<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHES/ASPHALT ADHES/ASPHALT ADHES/ASPHALT ADHES/ASPHALT ADHES/ASPHALT CONT. ADHES.<br />

X X X X X X X X X<br />

PER CODE PER CODE PER CODE PER CODE PER CODE PER CODE PER CODE PER CODE PER CODE DEAD LEVEL<br />

X<br />

X<br />

X O X O X O X X O X O X O X O X O S<br />

X<br />

X X X X X X X X X X<br />

X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X<br />

O S O S O S O S O S O S O S O S O S X<br />

O S O S O S O S O S O S O S O S O S O<br />

O S O S O S O S O S O S O S O S O S O<br />

O S O S O S O S O S O S O S O S O S O<br />

O S O S O S O S O S O S O S O S O S O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE SEE SPECS<br />

0 - 120 0 - 120 0 - 120 0 - 120 0 - 120 0 - 120 0 - 120 0 - 120 0 - 120 0 – 140<br />

REINFORCED REINFORCED REINFORCED REINFORCED REINFORCED REINFORCED REINFORCED REINFORCED REINFORCED PVC MEMBRANE<br />

MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE OR PVC-COATED<br />

COATED METAL COATED METAL COATED METAL COATED METAL COATED METAL COATED METAL COATED METAL COATED METAL COATED METAL METAL<br />

HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD ADHESIVE<br />

AND AND AND AND AND AND AND AND AND AND<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIV E ADHESIVE ADHESIVE ADHESIVE ADHESIVE HOT AIR WELD<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1988 1988 1988 1988 1990 1990 1990 1990 1990 1980<br />

1983<br />

THOUSANDS THOUSANDS THOSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS MILLIONS<br />

DIST/DIRECT DIST/DIRECT DIST/DIRECT DIST/DIRECT DIST/DIRECT DIST/DIRECT DIST/DIRECT DIST/DIRECT DIST/DIRECT DISTRIBUTORS<br />

4 4 4 4 4 4 4 4 4 8<br />

YES YES YES YES YES YES YES YES YES YES<br />

REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL SALES OFFICE<br />

OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE 800/443-4272<br />

TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECH. SERVICE<br />

SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES 800/443-4272<br />

293


PVC Part 1: General Information<br />

1. COMPANY NAME GLENFLEX GLENFLEX GLENFLEX GLENFLEX GENFLEX<br />

ROOFING ROOFING ROOFING ROOFING ROOFING<br />

SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS<br />

2. PRODUCT NAME GENFLEX GENFLEX GENFLEX GENFLEX GENFLEX<br />

RM .060 RMT .080 RM-C .048 RM-C .060 RM-FB<br />

3. PRODUCT DESCRIPTION<br />

Reinforcement POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

Colors WHITE / GRAY /<br />

TAN<br />

WHITE WHITE / GRAY /<br />

TAN<br />

WHITE / GRAY /<br />

TAN<br />

WHTIE<br />

Installed Weight (lbs./ft 2 w/o ballast) 0.40 0.51 0.30 0.30 0.30<br />

4. COATING REQUIRED NONE NONE NONE NONE NONE<br />

5. USE IN:<br />

New <strong>Roof</strong>ing X X X X X<br />

Reroofing X X X X X<br />

6. FIELD LAP JOINT METHOD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD<br />

0.45<br />

7. TYPES OF ROOF SYSTEMS<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method) MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST.<br />

Fully Adhered (method) CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. ADHES/ASPHALT<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL NONE<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber X X X X<br />

Mineral Fiber X X X X<br />

Polystyrene S S S S O<br />

Cellular Glass X X X X<br />

Phenolic<br />

Fiberboard X X X X X<br />

Perlite X X X X X<br />

Polyisocyanurate X X X X X<br />

Polyurethane<br />

Gypsum X X X X X O<br />

Concrete O O O O X O<br />

Wood Plank O O O O X O<br />

Plywood O O O O X O<br />

Existing Built-Up Membrane O O O O X O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE SPECS<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 0 – 140 0 - 140 0 – 140 0 – 140 0 - 140<br />

12. FLASHING MATERIAL PVC MEMBRANE PVC MEMBRANE PVC MEMBRANE PVC MEMBRANE PVC MEMBRANE<br />

OR PVC-COATED OR PVC-COATED OR PVC-COATED OR PVC-COATED OR PVC-COATED<br />

METAL METAL METAL METAL METAL<br />

13. FLASHING METHOD ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

AND AND AND AND AND<br />

HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA<br />

Manufacture USA USA USA USA USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1983 1999<br />

Within USA 1980 1989 1995 1995 1999<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA MILLIONS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS 8 8 8 8 8<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: SALES OFFICE SALES OFFICE SALES OFFICE SALES OFFICE SALES OFFICE<br />

800/443-4272 800/443-4272 800/443-4272 800/443-4272 800/443-4272<br />

22. TECHNICAL INFORMATION, CONTACT: TECH. SERVICE TECH. SERVICE TECH. SERVICE TECH. SERVICE TECH. SERVICE<br />

23. SEE APPENDIX IF CHECKED<br />

800/443-4272 800/443-4272 800/443-4272 800/443-4272 800/443-4272<br />

294


PVC Part 1: General Information<br />

GENFLEX IB ROOF IB ROOF IB ROOF IB ROOF JOHNS JOHNS JOHNS JOHNS JOHNS<br />

ROOFING SYSTEMS SYSTEMS SYSTEMS SYSTEMS MANVILLE MANVILLE MANVILLE MANVILLE MANVILLE<br />

SYSTEMS<br />

INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL<br />

GENFLEX IB SINGLE-PLY INSULATED SINGLE-PLY SINGLE-PLY ULTRAGARD ULTRAGARD ULTRAGARD ULTRAGARD ULTRAGARD<br />

RM-FB BLANKET 60 MIL. 80 MIL.. V250 V260 SR 50 SR 60 SR80<br />

0.6<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

WHTIE WHITE / TAN / WHITE / TAN / WHITE WHIE BLACK BLACK WHITE WHITE WHITE<br />

GRAY / BLUE GRAY / BLUE<br />

0.40 0.33 0.33 0.41 0.55 0.42 0.44 0.42 0.44 0.58<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR HOT AIR HOT AIR HOT AIR HOT AIR<br />

BALLASTED BALLASTED BALLASTED BALLASTED<br />

MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST.<br />

ADHES/ASPHALT CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES.<br />

NONE NONE NONE NONE NONE<br />

X X X X O O O O O<br />

S S S S S O S O S O S O S O<br />

O X S X S X S X S S O S O S O S O S O<br />

S X S S S O S O S O S O S O<br />

X X X X<br />

X X S X S X S X S X X X X X<br />

X X X X X X O X O X O X O X O<br />

X X X X X X X X X X<br />

X X X X X X X X X<br />

X O X X X X X O X O X O X O X O<br />

X O X S X S X S X S S O S O S O S O S O<br />

X O S S S S S O S O S O S O S O<br />

X O S S S S X S X S X S X S X S<br />

X O S S S S S O S O S O S O S O<br />

SEE SPECS NONE NONE NONE NONE SEE SPECS SEE SPECS SEE SPECS SEE SPECS SEE MFR<br />

0 - 140 0-120 0-120 0-120 0-120 0 – 120 0 – 120 0 – 120 0 – 120 0 – 120<br />

PVC MEMBRANE IB MEMBRANE IB MEMBRANE IB MEMBRANE IB MEMBRANE PVC-COATED PVC-COATED PVC-COATED PVC-COATED PVC-COATED<br />

OR PVC-COATED CPA CLAD METAL CPA CLAD METAL CPA CLAD METAL CPA CLAD METAL METAL / METAL / METAL / METAL / METAL /<br />

METAL PREFABRICATED PREFABRICATED PREFABRICATED PREFABRICATED REINFORCED REINFORCED REINFORCED REINFORCED REINFORCED<br />

FLASHING FLASHING FLASHING FLASHING MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE<br />

ADHESIVE HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

AND AND AND AND AND AND<br />

HOT AIR WELD HOT AIR HOT AIR HOT AIR HOT AIR HOT AIR<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA USA USA USA<br />

USA USA & CANADA USA & CANADA USA & CANADA USA & CANADA USA USA USA USA USA<br />

1999 1987 1987<br />

1999 1979 1979 1994 1994 1989 1986 1990<br />

THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

THOUSANDS MILLIONS MILLIONS MILLIONS MILLIONS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DISTRIBUTORS DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT<br />

8 5 5 5 5 4 4 4 4 4<br />

YES YES YES YES YES YES YES YES YES YES<br />

SALES OFFICE 800/426-1626 800/426-1626 800/426-1626 800/426-1626 REGIONAL OFFICEREGIONAL OFFICEREGIONAL OFFICEREGIONAL OFFICEREGIONAL OFFICE<br />

800/443-4272<br />

TECH. SERVICE 800/426-1626 800/426-1626 800/426-1626 800/426-1626 M. REW M. REW M. REW M. REW M. REW<br />

800/443-4272<br />

295


PVC Part 1: General Information<br />

1. COMPANY NAME MULE-HIDE MULE-HIDE MULE-HIDE MULE-HIDE SARNAFIL,<br />

PRODUCTS PRODUCTS PRODUCTS PRODUCTS INC.<br />

CO., INC. CO., INC. CO., INC. CO., INC.<br />

2. PRODUCT NAME MH 50 MH 60 PEM .040 PEM 060 SARNAFIL<br />

G 410<br />

3. PRODUCT DESCRIPTION<br />

Reinforcement POLYESTER POLYESTER POLYESTER POLYESTER FIBERGLASS<br />

Colors WHITE WHITE WHITE WHITE ASSORTED<br />

Installed Weight (lbs./ft 2 w/o ballast) 0.42 0.44 0.30 NOM 0.40 NOM 0.33<br />

4. COATING REQUIRED NONE NONE NONE NONE NONE<br />

5. USE IN:<br />

New <strong>Roof</strong>ing X X X X X<br />

Reroofing X X X X X<br />

6. FIELD LAP JOINT METHOD HEAT WELD HEAT WELD HEAT WELD HEAT WELD HOT AIR<br />

7. TYPES OF ROOF SYSTEMS<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method) MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST.<br />

Fully Adhered (method) CONT. ADHES. CONT. ADHES. CONT. ADHES.<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

8. MINIMUM SLOPE REQUIRED NONE NONE NONE<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber O O O O O<br />

Mineral Fiber S O S O O O O<br />

Polystyrene S O S O O O O<br />

Cellular Glass S O S O O O O<br />

Phenolic<br />

Fiberboard X X X X X<br />

Perlite X O X O X X O<br />

Polyisocyanurate X X X X X<br />

Polyurethane X X X X X<br />

Gypsum X O X O X O X O O<br />

Concrete S O S O S O S O X O<br />

Wood Plank S O S O S O S O O<br />

Plywood X S X S X S X S X O<br />

Existing Built-Up Membrane S O S O S O S O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) SEE SPECS SEE SPECS NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 0 – 120 0 – 120 0 – 120 0 – 120 0 – 120<br />

12. FLASHING MATERIAL PVC-COATED PVC-COATED REINFORCED REINFORCED G410, G459<br />

WELD<br />

METAL / METAL / MEMBRANE MEMBRANE CLAD METAL<br />

REINFORCED REINFORCED COATED COATED<br />

MEMBRANE MEMBRANE METAL METAL<br />

13. FLASHING METHOD ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

OR OR OR OR AND<br />

HOT WELD HOT WELT HOT WELT HOT WELT HEAT WELD<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA SWITZERLAND<br />

Manufacture USA USA USA USA USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1964<br />

Within USA 1989 1986 1986 1986 1975<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

THOUSANDS<br />

Within USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 12 12 15 15 6<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: 800/786-1492 800/786-1492 800/786-1492 800/786-1492 SALES DEPT.<br />

22. TECHNICAL INFORMATION, CONTACT: 800/786-1492 800/786-1492 800/786-1492 800/786-1492 TECH. DEPT.<br />

23. SEE APPENDIX IF CHECKED X<br />

296


PVC Part 1: General Information<br />

SARNAFIL,<br />

INC.<br />

SARNAFIL,<br />

INC.<br />

SARNAFIL SARNAFIL<br />

S 327 G 476<br />

POLYESTER<br />

ASSORTED<br />

FIBERGLASS<br />

ORANGE<br />

0.33 0.33<br />

NONE<br />

NONE<br />

X<br />

X<br />

HOT AIR<br />

WELD<br />

X<br />

X<br />

HOT AIR<br />

WELD<br />

MECH. FAST.<br />

NONE<br />

X<br />

NONE<br />

O<br />

O<br />

S<br />

O<br />

O<br />

O<br />

S<br />

X<br />

O<br />

X<br />

X<br />

X<br />

X<br />

S O S O<br />

S O S O<br />

S O S O<br />

X S O<br />

S O O<br />

NONE<br />

NONE<br />

0 – 120 0 – 120<br />

G410, G459, S327 G410, G459, S327<br />

OR<br />

CLAD METAL<br />

OR<br />

CLAD METAL<br />

ADHESIVE<br />

AND<br />

HEAT WELD<br />

ADHESIVE<br />

AND<br />

HEAT WELD<br />

YES<br />

YES<br />

SWITZERLAND<br />

USA<br />

SWITZERLAND<br />

USA<br />

1964 1964<br />

1978 1981<br />

THOUSANDS THOUSANDS<br />

THOUSANDS THOUSANDS<br />

DIRECT DIRECT<br />

6 6<br />

YES<br />

YES<br />

SALES DEPT. SALES DEPT.<br />

TECH. DEPT.<br />

TECH. DEPT.<br />

X<br />

X<br />

297


PVC Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4434-95<br />

1. COMPANY NAME FIRESTONE FIRESTONE FLEX FLEX GAF GAF<br />

BUILDING BUILDING MEMBRANE MEMBRAN MATERIALS MATERIALS<br />

PRODUCTS PRODUCTS INTERNATIONAL INTERNATIONAL CORP. CORP.<br />

2. PRODUCT NAME ULTRAPLY ULTRAPLY FLEX FLEX EVERGUARD EVERGUARD<br />

.045 .060 MF/R 50 MF/R 60 EGSR-40 EGSR-45<br />

3. TYPE I (unreinforced sheet)<br />

TYPE II (unreinforced sheet)<br />

GRADE 1 (containing fibers)<br />

GRADE 2 (containing fabrics)<br />

TYPE III (reinforced sheet containing fibers of fabrics) lll lll lll lll III III<br />

4. OVERALL THICKNESS (min. in.) 0.045 0.045 0.060 0.050 0.060 0.040 0.045<br />

5. TENSILE STRENGTH AT BREAK (min. psi) TYPE I;<br />

TYPE II; GRADE 1<br />

Machine Direction 1500 NA NA NA NA<br />

Cross-Machine Direction 1500 NA NA NA NA<br />

6. BREAKING STRENGTH (min. lbf/in.) TYPE II,<br />

350 350 > 230 > 250 305 320<br />

200<br />

GRADE 2; TYPE III<br />

7. ELONGATION AT BREAK (min. %) TYPE I; TYPE<br />

II; GRADE 1<br />

Machine Direction 250 NA NA NA NA<br />

Cross-Machine Direction 220 NA NA NA NA<br />

TYPE II, GRADE 2; TYPE III<br />

Machine Direction 15* 25 25 > 20 > 20 25 25<br />

Cross-Machine Direction 15* 25 25 > 20 > 20 25 25<br />

8. SEAM STRENGTH (min. % of tensile or breaking<br />

strength)<br />

75.0 80 80 > 80 > 80 >95 >95<br />

9. RETENTION OF PROPERTIES AFTER HEAT<br />

AGING (min. % of original)<br />

Tensile Strength TYPE I; TYPE II, GRADE 1 80.0 NA NA<br />

Breaking Strength (min. lbf/in.) 80.0 320 320 > 80 > 80 >95 >95<br />

Elongation at Break (min. %) TYPE I; TYPE II; GRADE 1 80.0 80 80 90 90 >95 >95<br />

10. TEAR RESISTANCE (min. lbf) TYPE I; TYPE II, GRADE 1 10.0 NA NA<br />

11. TEARING STRENGTH (min. lbf) TYPE II, GRADE 45.0 100 100 > 50 > 50 155 124<br />

2; TYPE III<br />

12. LOW TEMPERATURE BEND pass PASS PASS PASS PASS PASS PASS<br />

13. ACCELERATED WEATHERING TEST<br />

Cracking (7X magnification) none NONE NONE NONE NONE NONE NONE<br />

Discoloration (by observation) negligible NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE<br />

Crazing (7X magnification) none NONE NONE NONE NONE NONE NONE<br />

14. LINEAR DIMENSIONAL CHANGE (max. %)<br />

TYPE I 3.0 NA NA NA NA<br />

TYPE II 0.1 NA NA NA NA<br />

TYPE III 0.5 0.3 0.3 < 0.2 < 0.2 0.5 0.5<br />

15. CHANGE IN WEIGHT AFTER IMMERSION IN<br />

WATER (max %)<br />

16. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

* for reinforcing fabric only; elongation of PVC material<br />

shall be the same as Type I<br />

±3.0<br />

0.5 0.5 < 0.2 < 0.2 1.4 0.9<br />

298


PVC Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4434-95<br />

GAF GAF GAF GAF GAF GAF GAF GAF GENFLEX GENFLEX<br />

MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS ROOFING ROOFING<br />

CORP. CORP. CORP. CORP. CORP. CORP. CORP. CORP. SYSTEMS SYSTEMS<br />

EVERGUARD EVERGUARD EVERGUARD EVERGUARD EVERGUARD EVERGUARD EVERGUARD EVERGUARD GENFLEX GENFLEX<br />

EGSR-50 EGSR-60 EGSR-80 EGFB-40 EGFB-45 EGFB-50 EGFB-60 EGFB-80 RM .048 RM .060<br />

III III III III III III III III III III<br />

0.050 0.060 0.080 0.055 0.060 0.065 0.075 0.095 0.048 0.060<br />

332 363 416 428 428 442 435 501 210 210<br />

25 40 40 40 40 40 40 40 15 15<br />

25 40 40 35 35 35 35 40 15 15<br />

>95 >95 >95 >95 >95 >95 >95 >95 >75.0 >75.0<br />

>95 >95 >95 >95 >95 >95 >95 >95<br />

>95 >95 >95 >95 >95 >95 >95 >95 >95 >95<br />

NA<br />

107 97 109 135 135 152 119 89 50 50<br />

PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

NEGLIGIBLE NEBLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

0.5 0.5 0.5 0.5 0.5 0.3 0.2 0.1


PVC Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4434-95<br />

1. COMPANY NAME GENFLEX GENFLEX GENFLEX GENFLEX GENFLEX IB ROOF<br />

ROOFING ROOFING ROOFING ROOFING ROOFING SYSTEMS<br />

SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS<br />

2. PRODUCT NAME GENFLEX GENFLEX GENFLEX GENFLEX GENFLEX IB SINGLE-PLY<br />

3. TYPE I (unreinforced sheet)<br />

TYPE II (unreinforced sheet)<br />

GRADE 1 (containing fibers)<br />

GRADE 2 (containing fabrics)<br />

RM-T .080 RM-C .048 RM-C .060 RM-FB RM-FB<br />

.045 .060<br />

TYPE III (reinforced sheet containing fibers of fabrics) III III III III III III<br />

4. OVERALL THICKNESS (min. in.) 0.045 0.080 0.048 0.060 0.06 0.075 0.050<br />

5. TENSILE STRENGTH AT BREAK (min. psi) TYPE I;<br />

TYPE II; GRADE 1<br />

Machine Direction 1500<br />

Cross-Machine Direction 1500<br />

6. BREAKING STRENGTH (min. lbf/in.) TYPE II,<br />

200<br />

GRADE 2; TYPE III<br />

7. ELONGATION AT BREAK (min. %) TYPE I; TYPE<br />

II; GRADE 1<br />

Machine Direction 250<br />

Cross-Machine Direction 220<br />

TYPE II, GRADE 2; TYPE III<br />

300 210 210 300 300 300<br />

Machine Direction 15* 35 15 15 25 25 15<br />

Cross-Machine Direction 15* 40 15 15 25 25 15<br />

8. SEAM STRENGTH (min. % of tensile or breaking<br />

strength)<br />

75.0 > 90.0 >75.0 >75.0 >75 >75<br />

9. RETENTION OF PROPERTIES AFTER HEAT<br />

AGING (min. % of original)<br />

Tensile Strength TYPE I; TYPE II, GRADE 1 80.0<br />

Breaking Strength (min. lbf/in.) 80.0 80.0 >80 >80 90<br />

Elongation at Break (min. %) TYPE I; TYPE II; GRADE 1 80.0 80.0 >95 >95 >80 >80 90<br />

10. TEAR RESISTANCE (min. lbf) TYPE I; TYPE II, GRADE 1 10.0 NA NA NA<br />

11. TEARING STRENGTH (min. lbf) TYPE II, GRADE 45.0 100 50 50 80 80 50<br />

2; TYPE III<br />

12. LOW TEMPERATURE BEND pass PASS PASS PASS PASS PASS –40<br />

13. ACCELERATED WEATHERING TEST<br />

Cracking (7X magnification) none NONE NONE NONE NONE NONE NONE<br />

Discoloration (by observation) negligible NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE<br />

Crazing (7X magnification) none NONE NONE NONE NONE NONE NONE<br />

14. LINEAR DIMENSIONAL CHANGE (max. %)<br />

TYPE I 3.0<br />

TYPE II 0.1<br />

TYPE III 0.5 .3


PVC Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4434-95<br />

IB ROOF IB ROOF IB ROOF JOHNS JOHNS JOHNS JOHNS JOHNS MULE-HIDE MULE-HIDE<br />

SYSTEMS SYSTEMS SYSTEMS MANVILLE MANVILLE MANVILLE MANVILLE MANVILLE PRODUCTS PRODUCTS<br />

INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL CO., INC. CO., INC.<br />

INSULATED I B 60 MIL. IB 80 MIL. ULTRAGARD ULTRAGARD ULTRAGARD ULTRAGARD ULTRAGARD MH - 50 MH - 60<br />

BLANKET V 250 V 260 SR 50 SR 60 SR 80<br />

III III III III III III III III III III<br />

0.050 0.060 0.080 0.047 0.054 0.047 0.054 0.072 0.050 0.060<br />

NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA<br />

300 340 400 412 396 412 396 420 412 396<br />

NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA<br />

15 60 130 32 32 32 32 33 32 32<br />

15 40 90 33 34 33 34 37 33 34<br />

101 103 101 103 129 101 103<br />

NA NA NA NA NA NA NA<br />

90 90 95 107 91 107 91 99 107 91<br />

90 92 96 125 127 125 127 223 125 127<br />

NA NA NA NA NA NA NA<br />

50 68 73 69 53 69 53 74 69 53<br />

–40 PASS PASS PASS PASS PASS PASS PASS PASS PASS<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA<br />

0.5 0.5 0.5 0.14 0.12 0.14 0.12 0.14


PVC Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4434-95<br />

1. COMPANY NAME MULE-HIDE MULE-HIDE SARNAFIL SARNAFIL SARNAFIL<br />

PRODUCTS PRODUCTS INC. INC. INC.<br />

CO., INC.<br />

CO., INC.<br />

2. PRODUCT NAME PEM .040 PEM .060 SARNAFIL SARNAFIL SARNAFIL<br />

G 410 S 327 G 476<br />

3. TYPE I (unreinforced sheet)<br />

TYPE II (unreinforced sheet) II II<br />

GRADE 1 (containing fibers) 1 1<br />

GRADE 2 (containing fabrics)<br />

TYPE III (reinforced sheet containing fibers of fabrics) III III III<br />

4. OVERALL THICKNESS (min. in.) 0.045 0.040 0.060 0.048 0.048 0.048<br />

5. TENSILE STRENGTH AT BREAK (min. psi) TYPE I;<br />

TYPE II; GRADE 1<br />

Machine Direction 1500 NA NA 1600 NA 1650<br />

Cross-Machine Direction 1500 NA NA 1600 NA 1650<br />

6. BREAKING STRENGTH (min. lbf/in.) TYPE II,<br />

> 250 > 250 NA 230 NA<br />

200<br />

GRADE 2; TYPE III<br />

7. ELONGATION AT BREAK (min. %) TYPE I; TYPE<br />

II; GRADE 1<br />

Machine Direction 250 NA NA 270 NA 280<br />

Cross-Machine Direction 220 NA NA 250 NA 260<br />

TYPE II, GRADE 2; TYPE III<br />

Machine Direction 15* 30 30 NA 20 NA<br />

Cross-Machine Direction 15* 30 30 NA 20 NA<br />

8. SEAM STRENGTH (min. % of tensile or breaking<br />

strength)<br />

75.0 75.0 75.0 >80 >85 >80<br />

9. RETENTION OF PROPERTIES AFTER HEAT<br />

AGING (min. % of original)<br />

Tensile Strength TYPE I; TYPE II, GRADE 1 80.0 95 NA 95<br />

Breaking Strength (min. lbf/in.) 80.0 80 80 NA 95 NA<br />

Elongation at Break (min. %) TYPE I; TYPE II; GRADE 1 80.0 80 80 90 90 90<br />

10. TEAR RESISTANCE (min. lbf) TYPE I; TYPE II, GRADE 1 10.0 14 NA 14<br />

11. TEARING STRENGTH (min. lbf) TYPE II, GRADE 45.0 80 80 NA 50 NA<br />

2; TYPE III<br />

12. LOW TEMPERATURE BEND pass PASS PASS PASS PASS PASS<br />

13. ACCELERATED WEATHERING TEST<br />

Cracking (7X magnification) none NONE NONE NONE NONE<br />

Discoloration (by observation) negligible NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE NEGLIGIBLE<br />

Crazing (7X magnification) none NONE NONE NONE NONE<br />

14. LINEAR DIMENSIONAL CHANGE (max. %)<br />

TYPE I 3.0 NA NA NA NA NA<br />

TYPE II 0.1 NA NA 0.02 NA 0.02<br />

TYPE III 0.5


EPDM Part 1: General Information<br />

1. COMPANY NAME CARLISLE CARLISLE CARLISLE CARLISLE CARLISLE CARLISLE<br />

SYNTEC INC. SYNTEC INC. SYNTEC INC. SYNTEC INC. SYNTEC INC. SYNTEC INC.<br />

2. PRODUCT NAME SURE-SEAL SURE-SEAL SURE-SEAL SURE-SEAL BRITE-PLY SURE-SEAL<br />

EPDM FR FR HTM EPDM REINFORCED<br />

EPDM PLUS EPDM EPDM EPDM<br />

3. PRODUCT DESCRIPTION<br />

Reinforcement NONE NONE NONE NONE NONE YES<br />

Colors BLACK BLACK BLACK BLACK WHITE ON BLACK<br />

Installed Weight (lbs./ft 2 w/o ballast) 0.28 0.31 0.35 0.32 0.35 0.30<br />

4. COATING REQUIRED NONE NONE NONE NONE NONE NONE<br />

BLACK<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD TAPE OR TAPE OR TAPE OR TAPE OR CONTACT TAPE OR<br />

7. TYPES OF ROOF SYSTEMS<br />

CONTACT CONTACT CONTACT CONTACT ADHESIVE CONTACT<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 ) 10 10 10 10 10 10<br />

Partially Adhered (method) MECH. FAST. MECH. FAST.<br />

Fully Adhered (method) CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES.<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X X<br />

8. MINIMUM SLOPE REQUIRED NONE NONE NONE NONE NONE NONE<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber X O X O X O X O X O X O<br />

Mineral Fiber X O X O X O X O O X O<br />

Polystyrene X O X O X O X O X O X O<br />

Cellular Glass X X X X X X<br />

Phenolic<br />

Fiberboard X X X X X X<br />

Perlite X O X O X O X O X O X O<br />

Polyisocyanurate X X X X X X<br />

Polyurethane X X X X X X<br />

Gypsum X O X O X O X O X O X O<br />

Concrete X O X O X O X O X O X O<br />

Wood Plank X O X O X O X O X O X O<br />

Plywood X O X O X O X O X O X O<br />

Existing Built-up Membrane X O X O X O X O X O X O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) –49 TO 180 –49 TO 180 –49 TO 180 –49 TO 180 –49 TO 180 –49 TO 180<br />

12. FLASHING MATERIAL UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED<br />

OR OR OR OR OR OR<br />

CURED EPDM CURED EPDM CURED EPDM CURED EPDM CURED EPDM CURED EPDM<br />

13. FLASHING METHOD ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1963 1983 1983 1998 1977 1986<br />

Within USA 1963 1983 1983 1998 1977 1986<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 70 70 70 70 70 70<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: C. KUHL C. KUHL C. KUHL C. KUHL C. KUHL C. KUHL<br />

717/245–7000 717/245–7000 717/245–7000 717/245–7000 717/245–7000 717/245–7000<br />

22. TECHNICAL INFORMATION, CONTACT: S. IBRAHIM S. IBRAHIM S. IBRAHIM S. IBRAHIM S. IBRAHIM S. IBRAHIM<br />

23. SEE APPENDIX IF CHECKED<br />

717/245–7000 717/245–7000 717/245–7000 717/245–7000 717/245–7000 717/245–7000<br />

304


EPDM Part 1: General Information<br />

CARLISLE CARLISLE CARLISLE CARLISLE CELOTEX CELOTEX CELOTEX CELOTEX CELOTEX CELOTEX<br />

SYNTEC INC. SYNTEC INC. SYNTEC INC. SYNTEC INC. CORP. CORP. CORP. CORP. CORP. CORP.<br />

SURE-SEAL FR SURE-SEAL SURE-SEAL BRITE-PLY CELO I CELO I CELO I CELO I CELO I CELO I<br />

REINFORCED SURE-TOUGH FLEECEBACK FLEECEACK .045 .060 .060 .045 .045 .060<br />

EPDM EPDM EPDM REINFORCED REINFORCED REINFORCED<br />

YES YES YES YES NONE NONE NONE POLYESTER POLYESTER POLYESTER<br />

BLACK BLACK BLACK WHITE ON BLACK BLACK WHITE ON BLACK WHITE ON BLACK<br />

BLACK BLACK BLACK<br />

0.30 0.35 0.32 0.32 0.27 0.36 0.36 0.27 0.27 0.36<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

TAPE OR TAPE OR TAPE OR CONTACT CONT ADHES & CONT ADHES & CONT ADHES & CONT ADHES & CONT ADHES & CONT ADHES &<br />

CONTACT CONTACT CONTACT ADHESIVE SEALANT OR SEALANT OR SEALANT OR SEALANT OR SEALANT OR SEALANT OR<br />

ADHESIVE ADHESIVE ADHESIVE SEAM TAPE SEAM TAPE SEAM TAPE SEAM TAPE SEAM TAPE SEAM TAPE<br />

10 10<br />

MECH. FAST. MECH. FAST.<br />

CONT. ADHES. CONT. ADHES. URETHANE ADHES URETHANE ADHES<br />

X<br />

X<br />

NONE NONE NONE NONE 1/4" 1/4" 1/4" 1/4" 1/4" 1/4"<br />

X O X O X O X O X X X X<br />

X O X O O O X X X X<br />

X O X O X O X O X X X X<br />

X X X X X X X X<br />

X X X X X X X X X X<br />

X O X O O O X X X X<br />

X X X X X X X X X X<br />

X X X X X<br />

X O X O X O X O X X X X X X<br />

X O X O X O X O X X X<br />

X O X O X O X O X X X X<br />

X O X O X O X O X X X X X X<br />

X O X O X O X O X O X O X O X O X O X O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

–49 TO 180 –49 TO 180 –49 TO 180 –49 TO 180<br />

UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED UINCURED UNCURED UINCURED UNCURED<br />

OR OR OR OR EPDM EPDM WHITE EPDM WHITE EPDM<br />

CURED EPDM CURED EPDM CURED EPDM CURED EPDM EPDM EPDM<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE<br />

OR SELF-FLASH OR SELF-FLASH OR SELF-FLASH OR SELF-FLASH OR SELF-FLASH OR SELF-FLASH<br />

TAPE TAPE TAPE TAPE TAPE TAPE<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1986 1986<br />

1986 1986 1985 1985 1965 1965 1965 1965 1965 1965<br />

MILLIONS MILLIONS MILLIONS MILLIONS<br />

DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

70 70 70 70 6 6 6 6 6 6<br />

YES YES YES YES YES YES YES YES YES YES<br />

C. KUHL C. KUHL C. KUHL C. KUHL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

717/245–7000 717/245–7000 717/245–7000 717/245–7000 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE<br />

S. IBRAHIM S. IBRAHIM S. IBRAHIM S. IBRAHIM REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

717/245–7000 717/245–7000 717/245–7000 717/245–7000 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE<br />

305


EPDM Part 1: General Information<br />

1. COMPANY NAME CELOTEX ERSYSTEMS ERSYSTEMS ERSYSTEMS ERSYSTEMS ERSYSTEMS<br />

CORP.<br />

2. PRODUCT NAME CELO I ERSYSTEMS ERSYSTEM ERSYSTEMS ERSYSTEMS ERSYSTEMS<br />

.060 FR RUBBER ROOF RUBBER ROOF RUBBER ROOF RUBBER ROOF REINFORCED-90<br />

.060 BLACK .045 BLACK .060 BLACK FR .045 BLACK .045 BLACK<br />

3. PRODUCT DESCRIPTION<br />

Reinforcement NONE NONE NONE NONE NONE WOVEN<br />

POLY INSERT<br />

Colors BLACK BLACK BLACK BLACK BLACK BLACK<br />

Installed Weight (lbs./ft 2 w/o ballast) 0.36 0.35 0.25 0.35 0.25 0.30<br />

4. COATING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD CONT ADHES & CONTACT CONTACT CONTACT CONTACT CONTACT<br />

7. TYPES OF ROOF SYSTEMS<br />

SEALANT OR ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

SEAM TAPE OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 ) 10 MIN 10 MIN 10 MIN 10 MIN 10 MIN<br />

Partially Adhered (method) PLATE BONDED PLATE BONDED PLATE BONDED PLATE BONDED MECH. FAST.<br />

Fully Adhered (method) CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES.<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X X<br />

8. MINIMUM SLOPE REQUIRED 1/4" DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber X O O O O O<br />

Mineral Fiber X O O O O O<br />

Polystyrene X O O O O O<br />

Cellular Glass X O O O O O<br />

Phenolic O O O O O<br />

Fiberboard X X X X X X<br />

Perlite X O O O O O<br />

Polyisocyanurate X X X X X X<br />

Polyurethane O O O O O<br />

Gypsum O O O O O<br />

Concrete O O O O O<br />

Wood Plank X O O O O O<br />

Plywood X O O O O O<br />

Existing Built-up Membrane X O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 0 – 120 0 – 120 0 – 120 0 – 120 0 – 120<br />

12. FLASHING MATERIAL UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED<br />

WHITE EPDM OR EPDM OR EPDM OR EPDM OR EPDM OR<br />

EPDM NEOPRENE NEOPRENE NEOPRENE NEOPRENE NEOPRENE<br />

13. FLASHING METHOD CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA<br />

Within USA 1965 1965 1965 1965 1965 1989<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 6 14 14 14 14 14<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: REGIONAL T. LEONARD T. LEONARD T. LEONARD T. LEONARD T. LEONARD<br />

OFFICE 800/403–7747 800/403–7747 800/403–7747 800/403–7747 800/403–7747<br />

22. TECHNICAL INFORMATION, CONTACT: REGIONAL J. LEONARD J. LEONARD J. LEONARD J. LEONARD J. LEONARD<br />

23. SEE APPENDIX IF CHECKED<br />

OFFICE 800/403–7747 800/403–7747 800/403–7747 800/403–7747 800/403–7747<br />

306


EPDM Part 1: General Information<br />

ERSYSTEMS FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE<br />

BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING<br />

PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS<br />

ERSYSTEMS RUBBERGARD RUBBERGARD RUBBERGARD RUBBERGARD RUBBERGARD RUBBERGARD RUBBERGARD RUBBERGARD RUBBERGARD<br />

REINFORCED-90 .045 .060 .045 FR .060 FR .090 MAX .045 MAX .060 0.45 LSFR 0.060 LSFR<br />

.060 BLACK REINFORCED REINFORCED<br />

WOVEN NONE NONE NONE NONE NONE POLYESTER POLYESTER NONE NONE<br />

POLY INSERT<br />

BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK<br />

0.40 0.28 0.38 0.32 0.43 0.64 0.28 0.38 0.28 0.38<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

CONTACT SEAM TAPE SEAM TAPE SEAM TAPE SEAM TAPE SEAM TAPE W/ SEAM TAPE SEAM TAPE SEAM TAPE SEAM TAPE<br />

ADHESIVE<br />

FLASHING STRIP<br />

OR TAPE<br />

OVERLAY<br />

10 MIN 10 MIN 10 MIN 10 MIN 10 MIN 10 MIN 10 MIN 10 10<br />

MECH. FAST. BATTENS BATTENS BATTENS BATTENS BATTENS BATTENS BATTENS BATTENS<br />

CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES.<br />

X X X X X X X X X<br />

DEAD LEVEL POS. DRAIN POS. DRAIN POS. DRAIN POS. DRAIN POS. DRAIN POS. DRAIN POS. DRAIN POS. DRAIN POS. DRAIN<br />

O X O X O X O X O X O X O X O X O X O<br />

O X O X O X O X O X O X O X O X O X O<br />

O X O X O X O X O X O X O X O X O X O<br />

O X X X X X X O X X X<br />

O<br />

X X X X X X X X X X<br />

O X O X O X O X O X O X O X O X O X O<br />

X X X X X X X X X X<br />

O X X X X X X X X X<br />

O X O X O X O X O X O X O X O X O X O<br />

O X O X O X O X O X O X O X O X O X O<br />

O X O X O X O X O X O X O X O X O X O<br />

O X O X O X O X O X O X O X O X O X O<br />

O X O X X O X O X O X O X O X O X O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

0–120 0–100 0 – 100 0 – 100 0 – 100 0 – 100 0 – 100 0 – 100 0 – 100 0 – 100<br />

UNCURED EPDM / EPDM / EPDM / EPDM / EPDM / EPDM / EPDM / EPDM / EPDM<br />

EPDM OR QUICKSEAM QUICKSEAM QUICKSEAM QUICKSEAM QUICKSEAM QUICKSEAM QUICKSEAM QUICKSEAM QUICKSEAM<br />

NEOPRENE FLASHING FLASHING FLASHING FLASHING FLASHING FLASHING FLASHING FLASHING FLASHING<br />

CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT<br />

ADHESIVE ADHESIVE / ADHESIVE / ADHESIVE / ADHESIVE / ADHESIVE / ADHESIVE / ADHESIVE / ADHESIVE / ADHESIVE /<br />

OR TAPE TAPE TAPE TAPE TAPE TAPE TAPE TAPE TAPE TAPE<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1990 1990 1990 1990 1994 1994<br />

1989 1982 1982 1985 1985 1985 1990 1990 1994 1994<br />

THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

THOUSANDS MILLIONS MILLIONS MILLIONS MILLIONS THOUSANDS THOUSANDS THOUSANDS MILLIONS MILLIONS<br />

DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

14 5 5 5 5 5 5 5 5 5<br />

YES YES YES YES YES YES YES YES YES YES<br />

T. LEONARD 800/428–4442 800/428–4442 800/428–4442 800/428–4442 800/428–4442 800/428–4442 800/428–4442 800/428–4442 800/428–4442<br />

800/403–7747<br />

J. LEONARD 800/428–4511 800/428–4511 800/428–4511 800/428–4511 800/428–4511 800/428–4511 800/428–4511 800/428–4511 800/428–4511<br />

800/403–7747<br />

307


EPDM Part 1: General Information<br />

1. COMPANY NAME GENFLEX GENFLEX GENFLEX GENFLEX GENFLEX INTERNATIONAL<br />

ROOFING ROOFING ROOFING ROOFING ROOFING DIAMOND<br />

SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS, INC.<br />

2. PRODUCT NAME GENFLEX GENFLEX GENFLEX GENFLEX GENFLEX INTERNATIONAL<br />

.045 .060 FRM .045 FRM 0.60 AFR .060 BLACK<br />

BLACK BLACK BLACK BLACK BLACK EPDM .045<br />

3. PRODUCT DESCRIPTION<br />

Reinforcement NONE NONE YES YES NONE NONE<br />

Colors BLACK BLACK BLACK BLACK BLACK BLACK<br />

Installed Weight (lbs./ft 2 w/o ballast) 0.28 0.38 0.28 0.38 0.38 0.30<br />

4. COATING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD CONTACT CONTACT TAPE TAPE CONTACT CONTACT<br />

7. TYPES OF ROOF SYSTEMS<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

OR TAPE OR TAPE OR TAPE OR TAPE<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 ) 10 10 10 10 10<br />

Partially Adhered (method) MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST.<br />

Fully Adhered (method) CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES.<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X X<br />

8. MINIMUM SLOPE REQUIRED NONE NONE NONE NONE NONE DEAD LEVEL<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber X X X X X X<br />

Mineral Fiber X X X X X X<br />

Polystyrene O O O O O O<br />

Cellular Glass X X X X X X<br />

Phenolic<br />

Fiberboard X X X X X X<br />

Perlite X X X X X O<br />

Polyisocyanurate X X X X X X<br />

Polyurethane X X X X X X<br />

Gypsum X O X O X O X O X O X<br />

Concrete O O O O O S<br />

Wood Plank O O O O O S<br />

Plywood O O O O O X<br />

Existing Built-up Membrane O O O O O S<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 0 – 100 0 – 100 0 – 100 0 – 100 0 – 100 40 – 120<br />

12. FLASHING MATERIAL UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED<br />

EPDM EPDM EPDM EPDM EPDM EPDM<br />

13. FLASHING METHOD CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1982<br />

Within USA 1979 1979 1989 1989 1994 1982<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA MILLIONS MILLIONS THOUSANDS THOUSANDS MILLIONS MILLIONS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRS,DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 8 8 8 8 8 40<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: SALES SALES SALES SALES SALES J. DIAS<br />

800/443-4272 800/443-4272 800/443-4272 800/443-4272 800/443-4272 S. HALL<br />

22. TECHNICAL INFORMATION, CONTACT: TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE S. HALL<br />

23. SEE APPENDIX IF CHECKED<br />

800/443–4272 800/443–4272 800/443–4272 800/443–4272 800/443-4272 419/382–0111<br />

308


EPDM Part 1: General Information<br />

INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL JOHNS JOHNS JOHNS JOHNS JOHNS JOHNS<br />

DIAMOND DIAMOND DIAMOND DIAMOND MANVILLE MANVILLE MANVILLE MANVILLE MANVILLE MANVILLE<br />

SYSTEMS, INC. SYSTEMS, INC. SYSTEMS, INC. SYSTEMS, INC. INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL<br />

INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL SPM 45 SPM 45R SPM 60 SPM 60R SP 60 FR SPM 60 W<br />

BLACK FIRE RETARDANT REINFORCED REINFORCED BLACK BLACK BLACK BLACK BLACK WHITE<br />

.060 .060 .045 .060<br />

NONE NONE SCRIM SCRIM NONE POLYESTER NONE POLYESTER NONE NONE<br />

BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK WHITE<br />

0.40 0.50 0.40 0.50 0.29 0.30 0.38 0.39 0.39 0.41<br />

NONE NONE SCRIM SCRIM NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

CONTACT CONTACT CONTACT CONTACT CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE & SEALANT & SEALANT & SEALANT & SEALANT & SEALANT & SEALANT<br />

OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE<br />

10 MIN 10 MIN 10 MIN 10 MIN<br />

MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST.<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL NONE NONE NONE NONE NONE NONE<br />

X X X X O O O O O O<br />

X X X X O O O O O O<br />

O O O O O O O O O O<br />

X X X X O O O O O O<br />

X X X X X X X X X X<br />

O O O O X X X O X O X O X O<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X O X O O O O O<br />

S S S S X O X O X O X O X O X O<br />

S S S S X O X O X O X O X O X O<br />

X X X X X O X O X O X O X O X O<br />

S S S S O O O O O O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

40 – 120 40 – 120 40 – 120 40 – 120 25 – 160 25 – 160 25 – 160 25 – 160 25 – 160 25 – 160<br />

UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED<br />

EPDM EPDM EPDM EPDM OR OR OR OR OR OR<br />

CURED EPDM CURED EPDM CURED EPDM CURED EPDM CURED EPDM CURED EPDM<br />

CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE OR TAPR<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1982 1982 1982 1982<br />

1982 1982 1982 1982 1979 1993 1979 1993 1983 1983<br />

MILLIONS MILLIONS THOUSANDS THOUSANDS MILLIONS THOUSANDS MILLIONS THOUSANDS MILLIONS MILLIONS<br />

DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

40 40 40 40 5 5 5 5 5 5<br />

YES YES YES YES YES YES YES YES YES YES<br />

J. DIAS J. DIAS J. DIAS J. DIAS REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

S. HALL S. HALL S. HALL S. HALL OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE<br />

S. HALL S. HALL S. HALL S. HALL GUARANTEE GUARANTEE GUARANTEE GUARANTEE GUARANTEE GUARANTEE<br />

419/382–0111 419/382–0111 419/382–0111 419/382–0111 SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES<br />

309


EPDM Part 1: General Information<br />

1. COMPANY NAME JOHNS JOHNS JOHNS JOHNS JOHNS MULE-HIDE<br />

MANVILLE MANVILLE MANVILLE MANVILLE MANVILLE PRODUCTS<br />

INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL CO., INC.<br />

2. PRODUCT NAME ULTRAGARD ULRAGARD ULTRAGARD ULTRAGARD ULTRAGARD M-H<br />

.045 EPDM .045 R EPDM .060 FR EPDM .060 EPDM .060 R EPDM EPDM<br />

.045<br />

3. PRODUCT DESCRIPTION<br />

Reinforcement NONE POLYESTER NONE NONE POLYESTER NONE<br />

Colors BLACK BLACK BLACK WHITE BLACK BLACK<br />

Installed Weight (lbs./ft 2 w/o ballast) 0.29 0.30 0.35 0.41 0.39 0.30<br />

4. COATING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS<br />

& SEALANT OR & SEALANT OR & SEALANT OR & SEALANT OR & SEALANT OR & SEALANT<br />

TAPE TAPE TAPE TAPE TAPE OR TAPE<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 ) 10 min. 10 min. 10 min. 10 min. 10<br />

Partially Adhered (method)<br />

Fully Adhered (method)<br />

CONT. ADHES.<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

X<br />

8. MINIMUM SLOPE REQUIRED NONE<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber O O O O O O<br />

Mineral Fiber O O O O O O<br />

Polystyrene O O O O O X O<br />

Cellular Glass O O O O O X O<br />

Phenolic<br />

Fiberboard X X X X X X<br />

Perlite X X X O X X X O<br />

Polyisocyanurate X X X X X X<br />

Polyurethane X X X X X X<br />

Gypsum X O X O O O O X O<br />

Concrete X O X O X O X O X O X O<br />

Wood Plank X O X O X O X O X O X O<br />

Plywood X O X O X O X O X O X O<br />

Existing Built-up Membrane O O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 25 - 160 25 - 160 25 - 160 25 - 160 25 - 160 –49 – 180<br />

12. FLASHING MATERIAL UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED<br />

OR OR OR OR OR OR<br />

CURED EPDM CURED EPDM CURED EPDM CURED EPDM CURED EPDM CURED EPDM<br />

13. FLASHING METHOD CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT<br />

ADHESIVE OR ADHESIVE OR ADHESIVE OR ADHESIVE OR ADHESIVE OR ADHESIVE OR<br />

TAPE TAPE TAPE TAPE TAPE FLASHING TAPE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1986<br />

Within USA 1979 1993 1979 1983 1993 1963<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS/DIRECDT DISTRS/DIRECDT DISTRS/DIRECDT DISTRS/DIRECDT DISTRS/DIRECDT DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS 5 5 5 5 5 12<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL L. PUNZEL<br />

OFFICE OFFICE OFFICE OFFICE OFFICE 608/365–3111<br />

22. TECHNICAL INFORMATION, CONTACT: REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL T. MCFARLAND<br />

23. SEE APPENDIX IF CHECKED<br />

OFFICE OFFICE OFFICE OFFICE OFFICE 608/365–3111<br />

310


EPDM Part 1: General Information<br />

MULE-HIDE MULE-HIDE MULE-HIDE MULE-HIDE PROTECTIVE PROTECTIVE PROTECTIVE PROTECTIVE PROTECTIVE PROTECTIVE<br />

PRODUCTS PRODUCTS PRODUCTS PRODUCTS COATINGS COATINGS, COATINGS, COATINGS, COATINGS, COATINGS,<br />

CO., INC. CO., INC. CO., INC. CO., INC. INC. INC. INC. INC. INC. INC.<br />

M-H M-H M-H M-H PRO SHIELD PRO SHIELD PRO SHIELD PRO SHIELD PRO SHIELD PRO SHIELD<br />

EPDM REINFORCED REINFORCED W/B .060 BLACK BLACK BLACK WHITE WHITE WHITE<br />

.060 0.45 .060<br />

NONE YES YES NONE NONE NONE NONE NONE NONE NONE<br />

BLACK BLACK BLACK WHITE/BLACK BLACK BLACK BLACK WHITE WHITE WHITE<br />

0.40 0.30 0.40 0.40 0.40 0.50 0.60 0.40 0.50 0.60<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

CONT ADHESIVE CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT<br />

& SEALANT ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

OR TAPE AND TAPE AND SEALANT AND SEALANT AND SEALANT AND SEALANT AND SEALANT AND SEALANT AND SEALANT AND SEALANT<br />

10 10 10 10 10 10 10 10 10<br />

MECH. FAST. MECH. FAST. MECH. FAST. PLATE BONDED PLATE BONDED PLATE BONDED PLATE BONDED PLATE BONDED PLATE BONDED<br />

CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. CEMENT CONT. CEMENT CONT. CEMENT CONT. CEMENT CONT. CEMENT CONT. CEMENT<br />

X X X X<br />

NONE NONE NONE NONE DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL<br />

O O O X O X O X O X O X O X O<br />

O O O X O X O X O X O X O X O<br />

X O X O X O O X O X O X O X O X O X O<br />

X O X O X O X X O X O X O X O X O X O<br />

X O X O X O X O X O X O<br />

X X X X X O X O X X O X O X O<br />

X O X O X O O X X X X X X<br />

X X X X X X X X X X<br />

X X X X O X O X O X O X O X O X O<br />

X O X O X O X O X O X O X O X O X O X O<br />

X O X O X O X O X O X O X O X O X O X O<br />

X O X O X O X O X O X O X O X O X O X O<br />

X O X O X O X O X O X O X O X O X O X O<br />

O O O O X O X O X O X O X O X O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

–49 – 180 –49 – 180 –49 – 180 –49 – 180 0 – 120 0 – 120 0 – 120 0 – 160 0 – 160 0 – 160<br />

UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED<br />

OR OR OR OR EPDM EPDM EPDM EPDM EPDM EPDM<br />

CURED EPDM CURED EPDM CURED EPDM CURED EPDM<br />

CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT<br />

ADHESIVE OR ADHESIVE OR ADHESIVE OR ADHESIVE ADHESIVE & ADHESIVE & ADHESIVE & ADHESIVE & ADHESIVE & ADHESIVE &<br />

FLASHING TAPE FLASHING TAPE FLASHING TAPE SEALANT SEALANT SEALANT SEALANT SEALANT SEALANT<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1986 1982 1982 1982<br />

1963 1986 1986 1986 1965 1965 1965 1965 1965 1965<br />

MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS MILLIONS<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT<br />

12 12 12 12 10 10 10 10 10 10<br />

YES YES YES YES YES YES YES YES YES YES<br />

L. PUNZEL L. PUNZEL L. PUNZEL L. PUNZEL SALES SALES SALES SALES SALES SALES<br />

608/365–3111 608/365–3111 608/365–3111 608/365–3111 MANAGER MANAGER MANAGER MANAGER MANAGER MANAGER<br />

T. MCFARLAND T. MCFARLAND T. MCFARLAND T. MCFARLAND MURRELL MURRELL MURRELL MURRELL MURRELL MURRELL<br />

608/365–3111 608/365–3111 608/365–3111 608/365–3111<br />

311


EPDM Part 1: General Information<br />

1. COMPANY NAME PROTECTIVE ROOFING ROOFING ROOFING ROOFING ROOFING<br />

COATINGS, PRODUDTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS<br />

INC. INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL<br />

2. PRODUCT NAME PRO SHIELD RPE EPDM RPI EPDM RPI EPDM RPI EPDM RPI EPDM<br />

WHITE BLACK BLACK BLACK BLACK WHITE<br />

.045 .060 .045 .060 .045<br />

3. PRODUCT DESCRIPTION<br />

Reinforcement NONE NONE NONE POLYESTER POLYESTER NONE<br />

Colors WHITE / FIRE BLACK BLACK BLACK BLACK WHITE<br />

RETARDANT<br />

Installed Weight (lbs./ft 2 w/o ballast) 0.40 0.28 0.38 0.30<br />

4. COATING REQUIRED NONE NONE NONE NONE NONE NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD CONTACT CONT ADHESVIE CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS<br />

ADHESIVE & SEALANT & SEALANT & SEALANT & SEALANT & SEALANT<br />

AND SEALANT OR TAPE OR TAPE OR TAPE OR TAPE OR TAPE<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 ) 10 10 10 10 10<br />

Partially Adhered (method) PLATE BONDED BATTEN BATTEN PLATES PLATES BATTEN<br />

Fully Adhered (method) CONT. CEMENT CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES.<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X X<br />

8. MINIMUM SLOPE REQUIRED LEVEL LEVEL LEVEL LEVEL LEVEL<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber X O O O O O O<br />

Mineral Fiber X O O O O O O<br />

Polystyrene X O O O O O O<br />

Cellular Glass X O O O O O O<br />

Phenolic X O O O O O O<br />

Fiberboard X O X X X X X<br />

Perlite X O O O O O<br />

Polyisocyanurate X X O X O X O X O X O<br />

Polyurethane X O O O O O O<br />

Gypsum X O X O X O X O X O X O<br />

Concrete X O X O X O X O X O X O<br />

Wood Plank X O O O O O O<br />

Plywood X O X O X O X O X O X O<br />

Existing Built-up Membrane X O S O S O S O S O S O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 0 – 160 40 & ABOVE 40 & ABOVE 40 & ABOVE 40 & ABOVE 40 & ABOVE<br />

12. FLASHING MATERIAL UNCURED UNCURED UNCURED UNCURED UNCURED UNCURED<br />

EPDM EPDM EPDM EPDM EPDM EPDM<br />

METAL<br />

13. FLASHING METHOD CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT<br />

ADHESIVE & ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

SEALANT<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA<br />

Within USA 1982 1965 1965 1965 1965 1965<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA 1,000,000 THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS,DIRECT DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS 10 75 75 75 75 75<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: SALES 800/628–2957 800/628–2957 800/628–2957 800/628–2957 800/628–2957<br />

MANAGER<br />

22. TECHNICAL INFORMATION, CONTACT: MURRELL 800/628–2957 800/628–2957 800/628–2957 800/628–2957 800/628–2957<br />

23. SEE APPENDIX IF CHECKED<br />

312


EPDM Part 1: General Information<br />

ROOFING ROOFING ROOFING VERSICO VERSICO VERSICO VERSICO VERSICO VERSICO VERSICO<br />

PRODUCTS PRODUCTS PRODUCTS INC. INC. INC. INC. INC. INC. INC.<br />

INTERNATIONAL INTERNATIONAL INTERNATIONAL<br />

RPI EPDM RPI EPDM FR RPI EPDM FR VERSIGARD VERSIGARD III VERSIGARD VERSIGARD PE VERSIGARD II VERSIGARD VERSIGARD II<br />

WHITE BLACK BLACK EPDM EPDM EPDM EPDM FR REINFORCED FR<br />

.060 .045 .060 .045 .045 .060 .050 EPDM .060 EPDM .045 REINFORCED<br />

NONE NONE NONE NONE NONE NONE NONE NONE YES YES<br />

WHITE BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK<br />

0.40 0.30 0.40 0.28 0.28 0.38 0.31 0.40 0.30 0.30<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X<br />

X X X X X X X X X X<br />

CONT ADHESIVE CONT ADHESIVE CONT ADHESIVE CONTACT CONTACT CONTACT METAL CONTACT CONTACT CONTACT<br />

& SEALANT & SEALANT & SEALANT ADHESIVE OR ADHESIVE OR ADHESIVE RAIL ADHESIVE ADHESIVE ADHESIVE<br />

OR TAPE OR TAPE OR TAPE TAPE TAPE OR TAPE ASSEMBLY OR TAPE OR TAPE OR TAPE<br />

10 10 10 10 – 15 10 – 15 10 – 15 10 – 15 10 – 15 10 – 15<br />

BATTEN BATTEN BATTEN BATTENS BATTENS BATTENS METAL RAIL ASSY. MECH. FAST. MECH. FAST.<br />

CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES.<br />

X X X X X X X<br />

LEVEL LEVEL LEVEL NONE NONE NONE 1/2" IN 12" NONE NONE NONE<br />

O O O X O X O X O O X O X O<br />

O O O X O X O X O O X O X O<br />

O O O X O X O X O O O X O X O<br />

O O O X X X X X O X O<br />

O O O O<br />

X X X X X X X X X X<br />

O O O X O X O X O O O X O X O<br />

X O X O X O X X X X X X X<br />

O O O X X X X X O<br />

X O X O X O X O X O X O O X O X O<br />

X O X O X O X O X O X O X O X O X O<br />

O O O X O X O X O O X O X O<br />

X O X O X O X O X O X O X O X O X O<br />

S O S O S O X O X O X O O X O X O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

40 & ABOVE 40 & ABOVE 40 & ABOVE -224 -224 –48 – 180 –48 – 180 –49 – 180 –49 – 180 –25 – 180<br />

UNCURED UNCURED UNCURED CURED OR CURED OR CURED OR CURED OR CURED OR CURED OR CURED OR<br />

EPDM EPDM EPDM UNCURED EPDM UNCURED EPDM UNCURED EPDM UNCURED EPDM UNCURED EPDM UNCURED EPDM UNCURED EPDM<br />

CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT METAL RAIL CONTACT CONTACT CONTACT<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE ASSEMBLY ADHESIVE ADHESIVE ADHESIVE<br />

OR TAPE OR TAPE<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1982 1982 1982<br />

1965 1965 1965 1983 1983 1983 1986 1983 1986 1986<br />

THOUSANDS THOUSANDS THOUSANDS MILLIONS MILLIONS MILLIONS THOUSANDS MILLIONS MILLIONS THOUSANDS<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

75 75 75 125 125 125 125 125 125 125<br />

YES YES YES YES YES YES YES YES YES YES<br />

800/628–2957 800/628–2957 800/628–2957 M. MCAULEY M. MCAULEY M. MCAULEY M. MCAULEY M. MCAULEY M. MCAULEY M. MCAULEY<br />

800/992–7663 800/992–7663 800/992–7663 800/992–7663 800/992–7663 800/992–7663 800/992–7663<br />

800/628–2957 800/628–2957 800/628–2957 R. GIANGIULI R. GIANGIULI R. GIANGIULI R. GIANGIULI R. GIANGIULI R. GIANGIULI R. GIANGIULI<br />

800/992–7663 800/992–7663 800/992–7663 800/992–7663 800/992–7663 800/992–7663 800/992–7663<br />

313


EPDM Part 1: General Information<br />

1. COMPANY NAME VERSICO<br />

INC.<br />

2. PRODUCT NAME VERSIGARD I<br />

3. PRODUCT DESCRIPTION<br />

Reinforcement<br />

WHITE<br />

NONE<br />

Colors<br />

WHITE ON<br />

BLACK<br />

Installed Weight (lbs./ft 2 w/o ballast) 0.40<br />

4. COATING REQUIRED NONE<br />

5. USE IN<br />

New <strong>Roof</strong>ing<br />

Reroofing<br />

6. FIELD LAP JOINT METHOD COTNACT<br />

7. TYPES OF ROOF SYSTEMS<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered (method)<br />

Protected <strong>Roof</strong> Membrane Assembly<br />

X<br />

X<br />

ADHESIVE<br />

OR TAPE<br />

CONT. ADHES.<br />

8. MINIMUM SLOPE REQUIRED 1/8"<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber X O<br />

Mineral Fiber<br />

O<br />

Polystyrene X O<br />

Cellular Glass<br />

X<br />

Phenolic<br />

Fiberboard<br />

X<br />

Perlite X O<br />

Polyisocyanurate<br />

X<br />

Polyurethane<br />

X<br />

Gypsum X O<br />

Concrete X O<br />

Wood Plank X O<br />

Plywood X O<br />

Existing Built-up Membrane X O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) –49 – 180<br />

12. FLASHING MATERIAL CURED OR<br />

UNCURED EPDM<br />

13. FLASHING METHOD CONTACT<br />

ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES<br />

15. COUNTRY OF:<br />

Origin<br />

USA<br />

Manufacture<br />

USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1977<br />

Within USA 1977<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA<br />

THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS<br />

19. NUMBER OF REGIONAL LOCATIONS 125<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES<br />

21. SALES INFORMATION, CONTACT: M. MCAULEY<br />

800/992–7663<br />

22. TECHNICAL INFORMATION, CONTACT: R. GIANGIULI<br />

23. SEE APPENDIX IF CHECKED<br />

800/992–7663<br />

314


EPDM Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4637-96<br />

1. COMPANY NAME CARLISLE CARLISLE CARLISLE CARLISLE CARLISLE CARLISLE<br />

SYNTEC INC. SYNTEC INC. SYNTEC INC. SYNTEC INC. SYNTEC INC. SYNTEC INC.<br />

2. PRODUCT NAME SURE-SEAL SURE-SEAL SURE-SEAL SURE-SEAL BRITE-PLY SURE-SEAL<br />

EPDM FR FR HTM EPDM REINFORCED<br />

EPDM PLUS EPDM EPDM EPDM<br />

3. GRADE 1 (greater than 95% principal polymer) or 1 1 1 1 1 1<br />

GRADE 2 (50% <strong>to</strong> 95% principal polymer)<br />

4. CLASS U (unreinforced) or U U U U U<br />

CLASS SR (scrim or fabric internally reinforced)<br />

SR<br />

5. THICKNESS (min. in.)<br />

Sheet Overall 0.039 0.045 0.060 0.060 0.045 0.060 0.045<br />

Coating Over Scrim Class SR 0.015 NA NA NA NA NA 0.015<br />

6. BREAKING STRENGTH (min. lbf) CLASS SR 90 NA NA NA NA NA 180<br />

7. TENSILE STRENGTH (min. psi) CLASS U 1305 1630 1630 1830 2000 1685 NA<br />

8. ELONGATION, ULTIMATE (min. %)<br />

CLASS U 300 520 520 580 500 550 NA<br />

CLASS SR 250 NA NA NA NA NA 500<br />

9. TENSILE SET (max. %) CLASS U 10 5 5 5 5 7 NA<br />

10. TEAR RESISTANCE (min. lbf/in.) CLASS U 150 230 230 230 200 200 NA<br />

11. TEARING STRENGTH (min. lbf) CLASS SR 5 NA NA NA NA NA 30<br />

12. BRITTLENESS POINT (max. F) –49 –85 –85 –85 -85 -75 –75<br />

13. OZONE RESISTANCE (pass/fail) no cracks PASS PASS PASS PASS PASS PASS<br />

14. HEAT AGING<br />

Breaking Strength (min. lbf) CLASS SR 80 NA NA NA NA NA 175<br />

Tensile Strength (min. psi) CLASS U 1205 1500 1500 1860 2100 1550 NA<br />

Elongation, Ultimate (min. %) 200 310 310 250 250 250 250<br />

Tear Resistance (min. lbf/in.) CLASS U 125 215 215 240 215 185 NA<br />

Linear Dimensional Change (max. %) ± 2 –0.4 –0.4 –0.6 -0.4 -0.5 –0.7<br />

15. WATER ABSORPTION (max. mass %) +8, –2 +2.0 +2.0 +2.0 +2.0 +3.6 +2.0<br />

16. FACTORY SEAM STRENGTH (min. lbf/in.) 51 or sheet<br />

17. WEATHER RESISTANCE (pass/fail) no cracks<br />

failure X X X X NA NA<br />

18. SEE MEMBRANE APPENDIX IF CHECKED<br />

or crazing PASS PASS PASS PASS PASS PASS<br />

316


EPDM Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4637-96<br />

CARLISLE CARLISLE CARLISLE CARLISLE CELOTEX CELOTEX CELOTEX CELOTEX CELOTEX CELOTEX<br />

SYNTEC, INC. SYNTEC, INC. SYNTEC, INC. SYNTEC, INC. CORP. CORP. CORP. CORP. CORP. CORP.<br />

SURE-SEAL FR SURE-SEAL SURE-SEAL BRITE-PLY CELO I CELO I CELO I CELO I CELO I CELO I<br />

REINFORCED SURE-TOUGH FLEECEBBACK FLEECEBACK .045 .060 .060 .045 .045 .060<br />

EPDM EPDM EPDM REINFOFCED REINFORCED REINFORCED<br />

1 1 1 1 1 1<br />

SR SR FB FB<br />

U U U SR SR SR<br />

0.045 0.075 0.100, 0.115 0.100, 0.115<br />

0.015 0.020 0.045 0.045<br />

180 230 200 200 NA NA NA 100 100 100<br />

NA NA NA NA 1500 1500 1500 NA NA NA<br />

NA NA NA NA 350 350 350 NA NA NA<br />

500 500 500 500 NA NA NA 400 400 400<br />

NA NA NA NA 10 10 10 NA NA NA<br />

NA NA NA NA 175 175 175 NA NA NA<br />

30 74 45 45 NA NA NA 35 35 35<br />

–75 –75 –75 –75 –75 –75 –75 –75 –75 –75<br />

PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS<br />

175 220 200 200 NA NA NA 90 90 90<br />

NA NA NA NA 1450 1450 1450 NA NA NA<br />

250 250 310 250 225 225 225 250 250 250<br />

NA NA NA NA 150 150 150 NA NA NA<br />

–0.7 –0.7 –0.7 –0.7 –0.3 –0.3 –0.3 –0.3 –0.3 –0.3<br />

+2.0 +2.0 +2.0 +3.6 ±1.0 ±1.0 ±1.0 ±1.0 ±1.0 ±1.0<br />

NA NA NA NA NA NA NA 55 55 55<br />

PASS PASS PASS PASS NA NA NA NA NA NA<br />

317


EPDM Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4637-96<br />

1. COMPANY NAME CELOTEX ERSYSTEMS ERSYSTEMS ERSYSTEMS ERSYSTEMS ERSYSTEMS<br />

CORP.<br />

2. PRODUCT NAME CELO I ERSYSTEMS ERSYSTEMS ERSYSTEMS ERSYSTEMS ERSYSTEMS<br />

.060 FR RUBBER ROOF RUBBER ROOF RUBBER ROOF RUBBER ROOF REINFORCED 90<br />

.060 BLACK .045 .060 BLACK FR .045 BLACK FR .045 BLACK<br />

3. GRADE 1 (greater than 95% principal polymer) or 1 1 1 1 1<br />

GRADE 2 (50% <strong>to</strong> 95% principal polymer)<br />

4. CLASS U (unreinforced) or U U U U U<br />

CLASS SR (scrim or fabric internally reinforced)<br />

SR<br />

5. THICKNESS (min. in.)<br />

Sheet Overall 0.039 0.055 0.040 0.055 0.040 0.045<br />

Coating Over Scrim Class SR 0.015 NA NA NA NA 0.015<br />

6. BREAKING STRENGTH (min. lbf) CLASS SR 90 NA NA NA NA NA 100<br />

7. TENSILE STRENGTH (min. psi) CLASS U 1305 1500 1305 1305 1305 1305 NA<br />

8. ELONGATION, ULTIMATE (min. %)<br />

CLASS U 300 350 300 300 300 300 NA<br />

CLASS SR 250 NA NA NA NA NA 400<br />

9. TENSILE SET (max. %) CLASS U 10 10 10 10 10 10 NA<br />

10. TEAR RESISTANCE (min. lbf/in.) CLASS U 150 175 150 150 150 150 NA<br />

11. TEARING STRENGTH (min. lbf) CLASS SR 5 NA NA NA NA NA 200<br />

12. BRITTLENESS POINT (max. F) –49 –75 –49 –49 –49 –49 –75<br />

13. OZONE RESISTANCE (pass/fail) no cracks PASS PASS PASS PASS PASS PASS<br />

14. HEAT AGING<br />

Breaking Strength (min. lbf) CLASS SR 80 NA NA NA NA NA 90<br />

Tensile Strength (min. psi) CLASS U 1205 1450 1205 1205 1205 1205 NA<br />

Elongation, Ultimate (min. %) 200 225 200 200 200 200 250<br />

Tear Resistance (min. lbf/in.) CLASS U 125 150 125 125 125 125 NA<br />

Linear Dimensional Change (max. %) ± 2 –0.3 ±2 ±2 ±2 ±2 +1.0<br />

15. WATER ABSORPTION (max. mass %) +8, –2 ±1.0 +8, –2 +8, –2 +8, –2 +8, –2 +1.0<br />

16. FACTORY SEAM STRENGTH (min. lbf/in.) 51 or sheet<br />

17. WEATHER RESISTANCE (pass/fail) no cracks<br />

failure NA X X X X 50<br />

18. SEE MEMBRANE APPENDIX IF CHECKED<br />

or crazing NA PASS PASS PASS PASS PASS<br />

318


EPDM Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4637-96<br />

ERSYSTEMS FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE FIRESTONE<br />

BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING BUILDING<br />

PRODUCTS CO PRODUCTS CO PRODUCTS CO PRODUCTS CO PRODUCTS CO PRODUCTS CO PRODUCTS CO PRODUCTS CO PRODUCTS CO<br />

ERSYSTEMS RUBBERGARD RUBBERGARD RUBBERGARD RUBBERGARD RUBBERGARD RUBBERGARD RUBBERGARD RUBBERGRARD RUBBERGARD<br />

REINFORCED 90 .045 .060 .045 FR .060 FR .090 .045 .060 .045 LSFR .060 LSFR<br />

.060 BLACK REINFORCED REINFORCED<br />

1 1 1 1 1 1 1 1 1 1<br />

U U U U U U U<br />

SR SR SR<br />

0.060 0.045 0.060 0.045 0.060 0.090 0.045 0.060 0.045 0.045<br />

NA NA NA NA NA NA 0.015 0.015 NA NA<br />

NA NA NA NA NA 240 240 240 NA<br />

NA 1425 1425 1465 1465 1465 NA NA 1305 1435<br />

NA 450 450 350 350 350 NA NA 300 450<br />

400 NA NA NA NA NA 475 475 475 NA<br />

NA 10 10 10 10 10 NA NA 10 10<br />

NA 200 200 190 190 180 NA NA 150 200<br />

200 NA NA NA NA NA 60 60 60 NA<br />

–75 –49 –49 –49 –49 –49 –49 –49 –49 –49<br />

PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS<br />

90 NA NA NA NA NA 80 80 NA NA<br />

NA 1415 1450 1450 1450 1450 NA NA 1205 1425<br />

250 580 280 225 225 225 300 300 300 450<br />

NA 180 180 180 180 180 NA NA 125 205<br />

+1.0 ± 1 ± 1 ± 1 ± 1 ± 1 ± 1 ± 1 ± 1 ± 1<br />

+1.0 +8, –2 +8, –2 +8, –2 +8, –2 +8, –2 +8, –2 +8, –2 +8, –2 +8, –2<br />

SHEET FAILURE SHEET FAILURE SHEET FAILURE SHEET FAILURE SHEET FAILURE SHEET FAILURE SHEET FAILURE SHEET FAILURE SHEET FAILURE<br />

50 X X X X X X X X X<br />

PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS<br />

319


EPDM Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4637-96<br />

1. COMPANY NAME GENFLEX GENFLEX GENFLEX GENFLEX GENFLEX INTERNATIONAL<br />

ROOFING ROOFING ROOFING ROOFING ROOFING DIAMONS<br />

SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS, INC.<br />

2. PRODUCT NAME GENFLEX GENFLEX GENFLEX GENFLEX GENFLEX INTERNATIONAL<br />

.045 .060 FRM 0.45 FRM .060 AFR BLACK<br />

BLACK BLACK BLACK BLACK .060 BLACK EPDM .045<br />

3. GRADE 1 (greater than 95% principal polymer) or 1 1 1 1 1 1<br />

GRADE 2 (50% <strong>to</strong> 95% principal polymer)<br />

4. CLASS U (unreinforced) or U U U U<br />

CLASS SR (scrim or fabric internally reinforced) SR SR<br />

5. THICKNESS (min. in.)<br />

Sheet Overall 0.039 0.043 0.058 0.043 0.058 0.058 0.045<br />

Coating Over Scrim Class SR 0.015 NA NA 0.015 0.015 NA NA<br />

6. BREAKING STRENGTH (min. lbf) CLASS SR 90 NA NA 90 90 NA NA<br />

7. TENSILE STRENGTH (min. psi) CLASS U 1305 1305 1500 NA NA 1305 1305<br />

8. ELONGATION, ULTIMATE (min. %)<br />

CLASS U 300 300 450 NA NA 300 300<br />

CLASS SR 250 NA NA 300 300 NA NA<br />

9. TENSILE SET (max. %) CLASS U 10 10 10 NA NA 10 5<br />

10. TEAR RESISTANCE (min. lbf/in.) CLASS U 150 150 150 NA NA 150 150<br />

11. TEARING STRENGTH (min. lbf) CLASS SR 5 NA NA 50 50 NA NA<br />

12. BRITTLENESS POINT (max. F) –49 –49 –49 –49 –49 –49 –49<br />

13. OZONE RESISTANCE (pass/fail) no cracks PASS PASS PASS PASS PASS PASS<br />

14. HEAT AGING<br />

Breaking Strength (min. lbf) CLASS SR 80 NA NA 80 80 NA NA<br />

Tensile Strength (min. psi) CLASS U 1205 1500 1500 NA NA 1500 1305<br />

Elongation, Ultimate (min. %) 200 225 225 200 200 225 300<br />

Tear Resistance (min. lbf/in.) CLASS U 125 230 230 NA NA 230 150<br />

Linear Dimensional Change (max. %) ± 2 +1.0 +1.0 +1.0 +1.0 +1.0 +2<br />

15. WATER ABSORPTION (max. mass %) +8, –2 +8, –2 +8, –2 +8, –2 +8, –2 +8, –2 +8, –2<br />

16. FACTORY SEAM STRENGTH (min. lbf/in.) 51 or sheet 30<br />

failure X X X X X<br />

17. WEATHER RESISTANCE (pass/fail) no cracks<br />

18. SEE MEMBRANE APPENDIX IF CHECKED<br />

or crazing PASS PASS PASS PASS PASS PASS<br />

320


EPDM Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4637-96<br />

INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL JOHNS JOHNS JOHNS JOHNS JOHNS JOHNS<br />

DIAMOND DIAMOND DIAMOND DIAMOND MANVILLE MANVILLE MANVILLE MANVILLE MANVILLE MANVILLE<br />

SYSTEMS, INC. SYSTEMS, INC. SYSTEMS, INC. SYSTEMS, INC. INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL<br />

INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL SPM 45 SPM 45 R SPM 60 SPM 60 R SP 60 FR SPM 60W<br />

BLACK FIRE RETARDANT REINFORCED REINFORCED BLACK BLACK BLACK BLACK BLACK WHITE<br />

0.06 0.06 0.045 0.06<br />

1 1 1 1 1 1 1 1 1 1<br />

U U SR SR U SR U SR U U<br />

0.060 0.060 0.040 0.0\58 0.043 0.040 0.058 0.058 0.058 0.058<br />

NA NA 0.015 0.015 NA 0.015 NA 0.025 NA NA<br />

NA NA 90 90 NA 90 NA 90 NA NA<br />

1305 1305 NA NA 1650 NA 1485 NA 1470 1440<br />

300 300 NA NA 450 NA 470 NA 425 635<br />

NA NA 250 250 NA 250 NA 250 NA NA<br />

5 5 NA NA 4 NA 4 NA 3 2<br />

150 150 NA NA 200 NA 192 NA 201 211<br />

NA NA 10 10 NA 10 NA 10 NA NA<br />

–49 –49 -49 -49 –72 –49 –72 –49 –64 –80<br />

PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS<br />

NA NA 80 80 NA 80 NA 80 NA NA<br />

1305 1305 NA NA 1650 NA 1750 NA 1510 1480<br />

300 300 200 200 320 200 285 200 300 390<br />

150 150 NA NA 182 NA 182 NA 171 143<br />

+2 +2 ±2 ±2 –0.50 ± 2 –0.50 ± 2 –0.60 –1.50<br />

+8, –2 +8, –2 +8, -2 +8, -2 +1.7 +4.0 +1.7 +4.0 +2.8 +7.4<br />

30 30<br />

X X X X X X X X<br />

PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS<br />

321


EPDM Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4637-96<br />

1. COMPANY NAME JOHNS JOHNS JOHNS JOHNS JOHNS MULE-HIDE<br />

MANVILLE MANVILLE MANVILLE MANVILLE MANVILLE PRODUCTS<br />

INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL<br />

CO., INC.<br />

2. PRODUCT NAME ULTRAGARD ULTRAGARD ULTRAGARD ULTRAGARD ULTRAGARD M-H<br />

0.045 0.045R 0.060 FR 0.060R 0.060 WHITE EPDM 0.45<br />

3. GRADE 1 (greater than 95% principal polymer) or 1 1 1 1 1 1<br />

GRADE 2 (50% <strong>to</strong> 95% principal polymer)<br />

4. CLASS U (unreinforced) or U U U U<br />

CLASS SR (scrim or fabric internally reinforced) SR SR<br />

5. THICKNESS (min. in.)<br />

Sheet Overall 0.039 0.045 0.045 0.060 0.060 0.060 0.045<br />

Coating Over Scrim Class SR 0.015 NA 0.015 NA 0.020 NA NA<br />

6. BREAKING STRENGTH (min. lbf) CLASS SR 90 NA 180 NA 180 NA NA<br />

7. TENSILE STRENGTH (min. psi) CLASS U 1305 1630 NA 1630 NA 1305 1405+<br />

8. ELONGATION, ULTIMATE (min. %)<br />

CLASS U 300 520 NA 520 NA 350 350+<br />

CLASS SR 250 NA 500 NA 500 NA NA<br />

9. TENSILE SET (max. %) CLASS U 10 5 NA 5 NA 7 10<br />

10. TEAR RESISTANCE (min. lbf/in.) CLASS U 150 230 NA 230 NA 200 175<br />

11. TEARING STRENGTH (min. lbf) CLASS SR 5 NA 10 NA 10 NA NA<br />

12. BRITTLENESS POINT (max. F) –49 -75 -49 -75 -49 -75 –75<br />

13. OZONE RESISTANCE (pass/fail) no cracks PASS PASS PASS PASS PASS PASS<br />

14. HEAT AGING<br />

Breaking Strength (min. lbf) CLASS SR 80 NA 90 NA 90 NA NA<br />

Tensile Strength (min. psi) CLASS U 1205 1500 NA 1500 NA 1200 1205+<br />

Elongation, Ultimate (min. %) 200 310 250 310 250 200 250<br />

Tear Resistance (min. lbf/in.) CLASS U 125 245 NA 215 NA 125 150<br />

Linear Dimensional Change (max. %) ± 2 -0.4 -0.2 -0.4 -0.2 -0.2 ± 2<br />

15. WATER ABSORPTION (max. mass %) +8, –2 +2.0 +2.0 +2.0 +2.0 +2.0 +2<br />

16. FACTORY SEAM STRENGTH (min. lbf/in.) 51 or sheet<br />

17. WEATHER RESISTANCE (pass/fail) no cracks<br />

failure X NA X NA X X<br />

18. SEE MEMBRANE APPENDIX IF CHECKED<br />

or crazing PASS PASS PASS PASS PASS PASS<br />

322


EPDM Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4637-96<br />

MULE-HIDE MULE-HIDE MULE-HIDE MULE-HIDE PROTECTIVE PROTECTIVE PROTECTIVE PROTECTIVE PROTECTIVE PROTECTIVE<br />

PRODUCTS PRODUCTS PRODUCTS PRODUCTS COATINGS, COATINGS, COATINGS COATINGS COATINGS COATINGS<br />

CO., INC. CO., INC. CO., INC. CO., INC. INC. INC. INC. INC. INC. INC.<br />

M-H M-H M-H M-H PRO SHIELD PRO SHIELD PRO SHIELD PRO SHIELD PRO SHIELD PRO SHIELD<br />

EPDM .060 REINFORCED REINFORCED W/B BLACK BLACK BLACK WHITE WHITE WHITE<br />

EPDM .045 EPDM .060 EPDM .060<br />

1 1 1 1 1 1 1 1 1 1<br />

U U U U U U U U<br />

SR SR<br />

0.060 0.045 0.060 0.060 0.040 0.050 0.060 0.040 0.050 0.060<br />

NA NA NA NA NA NA NA NA NA NA<br />

NA 210 210 NA NA NA NA NA NA NA<br />

1405+ NA NA 1405+ 1400 1400 1400 1400 1400 1400<br />

350+ NA NA 350+ 300 300 300 300 300 300<br />

NA 250+ 250+ NA NA NA NA NA NA NA<br />

10 NA NA 10 10 10 10 10 10 10<br />

175 NA NA 175 200 200 200 200 200 200<br />

NA 50 50 NA NA NA NA NA NA NA<br />

–75 –75 –75 –75 –70 –70 –70 –70 –70 –70<br />

PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS<br />

NA 220 220 NA NA NA NA NA NA NA<br />

1205+ NA NA 1205+ 1205 1205 1205 1205 1205 1205<br />

250 250 250 250 200 200 200 200 200 200<br />

150 NA NA 150 125 125 125 125 125 125<br />

± 2 ± 2 ± 2 ± 2 +–2 +–2 +–2 +–2 +–2 +–2<br />

2 +3.6 +3.6 2 +8, –2 +8, –2 +8, –2 +8, –2 +8, –2 +8, –2<br />

X X X X X X X X X X<br />

PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS<br />

323


EPDM Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4637-96<br />

1. COMPANY NAME ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING<br />

PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS<br />

INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL INTERNATIONAL<br />

2. PRODUCT NAME RPI RPI RPI RPI RPI RPI<br />

EPDM FR EPDM FR EPDM EPDM EPDM EPDM<br />

BLACK 0.045 BLACK 0.060 BLACK .045 BLACK .045 BLACK .060 WHITE .060<br />

3. GRADE 1 (greater than 95% principal polymer) or 1 1 1 1 1 1<br />

GRADE 2 (50% <strong>to</strong> 95% principal polymer)<br />

4. CLASS U (unreinforced) or U U R U U U<br />

CLASS SR (scrim or fabric internally reinforced)<br />

5. THICKNESS (min. in.)<br />

Sheet Overall 0.039 0.040 0.054 0.040 0.054 0.054<br />

Coating Over Scrim Class SR 0.015 NA NA NA NA NA<br />

6. BREAKING STRENGTH (min. lbf) CLASS SR 90 NA NA NA NA NA<br />

7. TENSILE STRENGTH (min. psi) CLASS U 1305 1305 1305 1305 1305 1305<br />

8. ELONGATION, ULTIMATE (min. %)<br />

CLASS U 300 300 300 300 300 300<br />

CLASS SR 250 NA NA NA NA NA<br />

9. TENSILE SET (max. %) CLASS U 10<br />

10. TEAR RESISTANCE (min. lbf/in.) CLASS U 150 150 150 150 150 125<br />

11. TEARING STRENGTH (min. lbf) CLASS SR 5 NA NA NA NA NA<br />

12. BRITTLENESS POINT (max. F) –49 –49 –49 –49 –49 –49<br />

13. OZONE RESISTANCE (pass/fail) no cracks PASS PASS PASS PASS PASS<br />

14. HEAT AGING<br />

Breaking Strength (min. lbf) CLASS SR 80 NA NA NA NA NA<br />

Tensile Strength (min. psi) CLASS U 1205 1205 1205 1205 1205 1205<br />

Elongation, Ultimate (min. %) 200 200 200 200 200 200<br />

Tear Resistance (min. lbf/in.) CLASS U 125 125 125 125 125 125<br />

Linear Dimensional Change (max. %) ± 2 –2 –2 –2 –2 –2<br />

15. WATER ABSORPTION (max. mass %) +8, –2 0.05 0.05 0.05 0.05 0.05<br />

16. FACTORY SEAM STRENGTH (min. lbf/in.) 51 or sheet<br />

17. WEATHER RESISTANCE (pass/fail) no cracks<br />

failure X X X X X<br />

18. SEE MEMBRANE APPENDIX IF CHECKED<br />

or crazing PASS PASS PASS PASS PASS<br />

324


EPDM Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 4637-96<br />

ROOFING ROOFING VERSICO, VERSICO, VERSICO, VERSICO, VERSICO, VERSICO, VERSICO, VERSICO,<br />

PRODUCTS PRODUCTS INC. INC. INC. INC. INC. INC. INC. INC.<br />

INTERNATIONAL INTERNATIONAL<br />

RPI RPI VERSIGARD II VERSIGARD VERSIGARD VERSIGARD III VERSIGARD VERSIGARD PE VERSIGARD II VERSIGARD<br />

EPDM EPDM FR REINFORCED REINFORCED EPDM EPDM EPDM EPDM FR WHITE/BLACK<br />

BLACK .060 WHITE .045 EPDM .045 EPDM .045 .045 .045 .060 EPDM .060 0.060<br />

1 1 1 1 1 1 1 1 1 1<br />

R U U U U U U U<br />

SR SR<br />

0.040 0.045 0.045 0.045 0.045 0.060 0.045 0.060 0.060<br />

NA 0.015 0.015 NA NA NA NA NA NA<br />

NA 180 180 NA NA NA NA NA NA<br />

1305 NA NA 1630 2000 1630 1630 1630 1685<br />

300 NA NA 520 500 520 520 520 550<br />

NA 500 500 NA NA NA NA NA NA<br />

NA NA 5 5 5 5 5 7<br />

125 NA NA 230 200 230 230 230 200<br />

NA 30 30 NA NA NA NA NA NA<br />

–49 -75 –75 -85 85 -85 -85 -85 –75<br />

PASS PASS PASS PASS PASS PASS PASS PASS PASS<br />

NA 175 175 NA NA NA NA NA NA<br />

1205 NA NA 1500 2100 1500 1500 1500 1550<br />

200 250 250 310 250 310 310 310 250<br />

125 NA NA 215 215 215 215 215 185<br />

–2 -0.7 –0.7 -0.4 -0.4 -0.4 -0.4 -0.4 -0.5<br />

0.05 2 2 +2 +2 +2 +2 +2 +3.6<br />

X X X X X X X X X<br />

PASS PASS PASS PASS PASS PASS PASS PASS PASS<br />

325


CSPE (Hypalon) Part 1: General Information<br />

1. COMPANY NAME CONKLIN MULE-HIDE STEVENS STEVENS TREMCO<br />

CO., INC. PRODUCTS ROOFING ROOFING INC.<br />

CO., INC. SYSTEMS SYSTEMS<br />

2. PRODUCT NAME HY-CROWN M-H STEVENS STEVENS TREMCO<br />

45 MILS HYPALON HYPALON HYPALON HP 4510<br />

0.045 0.045 0.06<br />

3. PRODUCT DESCRIPTION<br />

Reinforcement POLYESTER 10 X 10 POLYESTER POLYESTER 10 X 10 WOVEN<br />

POLYESTER POLYESTER<br />

Color VARIOUS WHITE WHITE WHITE WHITE/BLACK<br />

Installed Weight (lbs./ft 2 w/o ballast) 0.32 0.29 MIN 0.29 MIN 0.43 MIN<br />

4. COATING REQUIRED NONE NONE NONE NONE NONE<br />

5. USE IN:<br />

New <strong>Roof</strong>ing X X X X X<br />

Reroofing X X X X X<br />

6. FIELD LAP JOINT METHOD WELD SOLUTION HEAT WELD HEAT WELD HEAT WELD CONTACT<br />

7. TYPES OF ROOF SYSTEMS<br />

OR<br />

HEAT WELD<br />

ADHESIVE<br />

OR HEAT WELD<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 ) 10 10 10 10 10<br />

Partially Adhered (method) MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST. MECH. FAST.<br />

Fully Adhered (method) CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES.<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN NONE NONE NONE 1/4"<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some/all circumstances)<br />

Glass Fiber X X X X<br />

Mineral Fiber X X X X<br />

Polystyrene S X S O X O X O O<br />

Cellular Glass X X X O X O O<br />

Phenolic X X O X O<br />

Fiberboard X X X O X O X<br />

Perlite X X X O X O O<br />

Polyisocyanurate X X X X X<br />

Polyurethane X X X X X<br />

Gypsum X X X X O<br />

Concrete O X X X O<br />

Wood Plank X O X X X O<br />

Plywood X O X X X O<br />

Existing Built-Up Membrane O O X O X O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) –25 – 140 –25 – 140 –25 – 140 –25 – 140<br />

12. FLASHING MATERIAL REINFORCED & REINFORCED & REINFORCED & REINFORCED & REINFORCED<br />

UNREINFORCED UNREINFORCED UNREINFORCED UNREINFORCED<br />

CLAD METAL HYPALON HYPALON HYPALON<br />

HYPALON<br />

13. FLASHING METHOD CONT ADHESIVE CONTACT CONTACT CONTACT CONTACT<br />

& SOLUTION ADHESIVE & ADHESIVE ADHESIVE ADHESIVE<br />

OR HEAT WELD HEAT WELD & HEAT WELD & HEAT WELD & HEAT WELD<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA<br />

Manufacture USA USA USA USA USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1977 1977<br />

Within USA 1985 1978 1978 1978 1981<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

MILLIONS<br />

Within USA >2,000,000 MILLIONS MILLIONS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 5 12 125 125 14<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: BLDG. PRODS. L. PUNZEL R. DUCLOS R. DUCLOS SALES OFFICE<br />

800/888-8838 608/365–3111 800/621-R00F 800/621-ROOF<br />

22. TECHNICAL INFORMATION, CONTACT: PROD. SERVS. T. MCFARLAND TECH. DEPT. TECH. DEPT. TECH. DEPT.<br />

23. SEE APPENDIX IF CHECKED<br />

800/888-8838 608/365–3111 800/621–ROOF 800/621–ROOF<br />

326


CSPE (Hypalon) Part 2: Test Results<br />

description and suggested values as specified in ASTM D 5019-96<br />

Test<br />

1. COMPANY NAME CONKLIN MULE-HIDE STEVENS STEVENS TREMCO<br />

CO., INC. PRODUCTS ROOFING ROOFING INC.<br />

CO., INC. SYSTEMS SYSTEMS<br />

2. PRODUCT NAME HY-CROWN M-H STEVENS STEVENS HP 4510<br />

45 MILS HYPALON HYPALON HYPALON<br />

3. SHEET CONSTRUCTION<br />

Grade 1 (backed without fibers)<br />

0.045 0.045 0.060<br />

Grade 2 (internally reinforced with fabric) 2 2 2 2 2<br />

PHYSICAL PROPERTIES OF SHEET<br />

4. THICKNESS (min. in.) 0.036 0.045 0.045 0.045 0.06 0.045<br />

5. BREAKING STRENGTH (min. lbf)<br />

Grade 1 50 NA NA NA NA NA<br />

Grade 2 (fabric) 125 225 225 280 280 225<br />

6. ELONGATION (min. %)<br />

Grade 1 250 NA NA NA NA NA<br />

Grade 2 (fabric) 15 81 15 15 15 25<br />

7. TEARING STRENGTH (min. lbf)<br />

Grade 1 10 NA NA NA NA NA<br />

Grade 2 (fabric) 25 90 90 110 110 225<br />

8. LOW-TEMPERATURE BEND pass PASS PASS PASS PASS PASS<br />

9. LINEAR DIMENSIONAL CHANGE (max. %)<br />

Grade 1 1.0 NA NA NA NA NA<br />

Grade 2 (fabric) 2.0 1.0 2.0 0.1 0.1 0.1<br />

10. FABRIC ADHESION (min. lbf/in. width)<br />

Grade 1 A* NA NA NA NA NA<br />

11. PLY ADHESION (min. lbf/in.)<br />

Grade 2 6 10 10 10 10 10<br />

12. HYDROSTATIC RESISTANCE (min. psi)<br />

Grade 1 15 NA NA NA NA NA<br />

Grade 2 160 300 300 400 400 300<br />

13. OZONE RESISTANCE OF SHEET (no cracks) pass PASS PASS PASS PASS PASS<br />

14. WEATHER RESISTANCE (no cracks or crazing) pass PASS PASS PASS PASS PASS<br />

PHYSICAL PROPERTIES OF THE COATING PORTION OF THE WEATHER SIDE OF SHEET<br />

15. TENSILE STRENGTH (min. psi) 700 1000 1000 1000 1000 1000<br />

16. ELONGATION (min. %) 300 400 300 300 300 400<br />

17. TEAR RESISTANCE (min. lbf/in.) 150 320 150 150 150 300<br />

18. OZONE RESISTANCE (no cracks) pass PASS PASS PASS PASS PASS<br />

19. WATER ABSORPTION (max. mass %) 10 8 10 10 10 8<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA=not applicable<br />

A=internal delamination of backing occurs prior <strong>to</strong><br />

failure <strong>to</strong> bond between backing and coating<br />

327


PIB (Polyisobutylene) Part 1: General Information<br />

1. COMPANY NAME REPUBLIC TREMCO TREMCO<br />

POWDERED INC. INC.<br />

METALS, INC.<br />

2. PRODUCT NAME GEOFLEX TREMFAST TREMFAST<br />

100 HD 120 HD<br />

3. PRODUCT DESCRPTION<br />

Reinforcement POLYESTER POLYESTER POLYESTER<br />

Color(s) WHITE WHITE WHITE<br />

Installed Weight(lbs./ft 2 w/o ballast) 0.57 0.6 0.75<br />

4. COATING REQUIRED NONE NONE NONE<br />

5. USE IN:<br />

New <strong>Roof</strong>ing X X X<br />

Reroofing X X X<br />

6. FIELD LAP JOINT METHOD PEEL & SELF- SELF-<br />

STICK ADHESIVE ADHESIVE<br />

7. TYPES OF ROOF SYSTEMS<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 ) 10<br />

Partially Adhered (method) ASPH OR ADHES HOT OR COLD HOT OR COLD<br />

Fully Adhered (method) ADHESIVE COLD ADHESIVE COLD ADHESIVE<br />

Protected <strong>Roof</strong> Membrane Assembly X X X<br />

8. MINIMUM SLOPE REQUIRED POS DRAIN POS DRAIN POS DRAIN<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber X X X<br />

Mineral Fiber X X X<br />

Polystyrene O<br />

Cellular Glass X X X<br />

Phenolic<br />

X<br />

Fiberboard X X X<br />

Perlite X O O<br />

Polyisocyanurate X O X O X O<br />

Polyurethane O O O<br />

Gypsum X O O O<br />

Concrete X O O O<br />

Wood Plank X O O O<br />

Plywood X O O O<br />

Existing Built-up Membrane X O X O X O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 40 – 100 40 - 100 40 - 100<br />

12. FLASHING MATERIAL REINFORCED REINFORCED REINFORCED<br />

AND AND AND<br />

UNREINFORCED UNREINFORCED PIB UNREINFORCED PIB<br />

13. FLASHING METHOD SELF-SEAL SELF-SEAL SELF-SEAL<br />

AND AND AND<br />

CONTACT ADHESIVE CONTACT ADHESIVE CONTACT ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES<br />

15. COUNTRY OF:<br />

Origin GERMANY GERMANY GERMAY<br />

Manufacture USA USA USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outrside USA 1950 1950 1950<br />

Within USA 1977 1997 1997<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outrside USA<br />

MILLIONS<br />

Within USA<br />

THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DIRECT DIRECT DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 6 14 14<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES<br />

21. SALES INFORMATION, CONTACT: 800/551-7081 SALES OFFICE SALES OFFICE<br />

22. TECHNICAL INFORMATION, CONTACT: 800/551-7081 TECH. DEPT. TECH. DEPT.<br />

23. SEE APPENDIX IF CHECKED<br />

328


PIB (Polyisobutylene ) Part 2: Test Results<br />

Test description and suggested values as specified in ASTM D 5019-96<br />

1. COMPANY NAME REPUBLIC TREMCO TREMCO<br />

POWDERED INC. INC.<br />

METALS, INC.<br />

2. PRODUCT NAME GEOFLEX TREMFAST TREMFAST<br />

100 HD 120 HD<br />

PHYSICAL PROPERTIES OF SHEET<br />

3. THICKNESS (min. in.) 0.087 0.100 0.100 0.120<br />

4. BREAKING STRENGTH (min. lbf) 140 188 188 188<br />

5. ELONGATION (min. %) 50 79 79 79<br />

6. TEARING STRENGTH (min. lbf) 30 38 38 38<br />

7. LOW TEMPERATURE BEND pass PASS PASS PASS<br />

8. LINEAR DIMENSIONAL CHANGE (max. %) 1.0 0.1 0.1 0.1<br />

9. FABRIC ADHESION (min. lbf/in.) 7 12 12 12<br />

10. HYDROSTATIC RESISTANCE (min. psi) 175 290 290 290<br />

11. OZONE RESISTANCE (no cracks) pass PASS PASS PASS<br />

12. WEATHER RESISTANCE (no cracks or crazing) pass PASS PASS PASS<br />

PHYSICAL PROPERTIES OF THTE COATING PORTION ON THE WEATHER SIDE OF SHEET<br />

13. TENSILE STRENGTH (min. psi) 600 1000 1000 1000<br />

14. ELONGATION (min. %) 400 600 600 600<br />

15. TEAR RESISTANCE (min. lbf/in.) 100 100 100 100<br />

16. OZONE RESISTANCE (no cracks) pass PASS PASS PASS<br />

17. WATER ABSORPTION (max. mass %) 1.0 0.5 1 1<br />

18. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

329


TPO Part 1: General Information<br />

1. COMPANY NAME CARLISLE FIRESTONE FIRESTONE GAF GAF<br />

SYNTEC BUILDING BUILDING MATERIALS MATERIALS<br />

INC. PRODUCTS PRODUCTS CORP. CORP.<br />

2. PRODUCT NAME SURE-WELD ULTRA PLY ULTRA PLY EVERGUARD EVERGUARD<br />

& GSD 45 MIL 60 MIL TPOSR-45 TPOSR-60<br />

3. PRODUCT DESCRIPTION<br />

Reinforcement POLYESTER POLY/SCRIM POLY/SCRIM POLYESTER POLYESTER<br />

Color(s) WHITE, GRAY OR WHITE WHITE WHITE / WHITE /<br />

TAN ON BLACK BLACK BLACK<br />

Installed Weight (lbs./ft 2 w/o ballast) 0.25 0.24 0.31 0.29 0.38<br />

4. COATING REQUIRED NONE NONE NONE NONE NONE<br />

5. USE IN:<br />

New <strong>Roof</strong>ing X X X X X<br />

Reroofing X X X X X<br />

6. FIELD LAP JOINT METHOD HEAT WELD HEAT WELD HEAT WELD HOT AIR WELD HOT AIR WELD<br />

7. TYPES OF ROOF SYSTEMS<br />

Loose Laid/Ballasted (ballast: lbs./ft 2 ) 10 10 10 10<br />

Partially Adhered (method) MECH. FAST. MECH FAST MECH FAST MECH FAST MECH FAST<br />

Fully Adhered (method) CONT. ADHES ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

Protected <strong>Roof</strong> Membrane Assembly N/A N/A X X<br />

8. MINIMUM SLOPE REQUIRED DEAD LEVEL 1/4" 1/4" PER CODE PER CODE<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber O O<br />

Mineral Fiber O O O<br />

Polystyrene O X X X O X O<br />

Cellular Glass X X X<br />

Phenolic<br />

Fiberboard X X X X X<br />

Perlite O O O<br />

Polyisocyanurate X X X X X<br />

Polyurethane X O O X X<br />

Gypsum X O X X O S O S<br />

Concrete X O X X O S O S<br />

Wood Plank X O X X O S O S<br />

Plywood X O X X O S O S<br />

Existing Built-Up Membrane X O O O O S O S<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE N/A N/A NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) -25 - 180 0 - 150 0 - 150 0 - 120 0 - 120<br />

12. FLASHING MATERIAL REINFORCED & REINFORCED REINFORCED<br />

UNREINFORCED MEMBRANE MEMBRANE<br />

MEMBARNE COATED METAL COATED METAL<br />

13. FLASHING METHOD HEAT WELD & HEAT WELD HEAT WELD HOT AIR HOT AIR<br />

CONTACT OR TAPE OR TAPE WELD AND WELD AND<br />

ADHESIVE ADHESIVE ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES<br />

15. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1978 1978<br />

Within USA 1991 1998 1998 1998 1998<br />

16. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA MILLIONS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

17. MANUFACTURING PLANT LOCATION(S) (City, State) HENDERSON, NV HENDERSON, NV HENDERSON, NV HENDERSON, NV<br />

MT. VERNON, IN<br />

MT, VERNON, IN<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DIST/DIRECT DIST/DIRECT DIST/DIRECT DIST/DIRECT DIST/DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 70 4 4<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: C. KUHL PAUL OLIVEiRA PAUL OLIVEIRA REGIONAL REGIONAL<br />

717/245-7000 317/575-7186 317/575-7186 OFFICE OFFICE<br />

22. TECHNICAL INFORMATION, CONTACT: S.IBRAHIM JEFF HENEGAR JEFF HENEGAR REGIONAL REGIONAL<br />

23. SEE APPENDIX IF CHECKED<br />

717/245-7000 317/575-7028 317/575-7028 OFFICE OFFICE<br />

330


TPO Part 1: General Information<br />

GENFLEX GENFLEX JOHNS JOHNS STEVENS STEVENS STEVENS STEVENS STEVENS STEVENS<br />

ROOFING ROOFING MANVILLE MANVILLE ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING<br />

SYSTEMS SYSTEMS INTERNATIONAL INTERNATIONAL SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS<br />

.045 TPO .060 TPO ULTRAGARD ULTRAGARD STEVENS EP STEVENS EP EP-P EP-B EP-FLEECE EP-FLEECE<br />

SRT-45 SRT-60 0.045 0.060 0.045 0.060 0.080 0.095<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLY/FLEECE POLY/FLEECE<br />

WHITE/BLACK/ WHITE/BLACK/ WHITE WHITE BLACK/WHITE/ BLACK/WHITE/ TAN TAN WHITE / BLACK / WHITE / BLACK /<br />

GRAY GRAY GRAY/OTHERS GRAY/OTHERS GRAY GRAY<br />

0.21 0.29 0.29 0.38 0.21 0.3 0.21 0.30 0.25 0.34<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HEAT WELD HEAT WELD HEAT WELD HEAT WELD HEAT WELD HEAT WELD<br />

10 10 10 10 10 10 10 10 NA NA<br />

MECH FAST MECH FAST MECH FAST MECH FAST MECH FAST MECH FAST NA NA MECH FAST MECH FAST<br />

CONT ADHES CONT ADHES ADHESIVE ADHESIVE CONT ADHES CONT ADHES NA NA ADHESIVE ADHESIVE<br />

X X X X X X X X<br />

LEVEL LEVEL NONE NONE NONE NONE NONE NONE NONE NONE<br />

O O O O X X X X X X<br />

X O X O O O X X X X X X<br />

X O X O X X X O X O X O X O X O X O<br />

X X X X X O X O X O X O X O X O<br />

X X X X X O X O X O X O X O X O<br />

X X X X X O X O X O X O X O X O<br />

X X X X X X X X X X<br />

X X X X X X X X<br />

X X X X X X X X X X<br />

X O X O X X X X X X X X<br />

S O S O X X X X X X X X<br />

S O S O X X X X X X X X<br />

O O O O X O X O X O X O X O X O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

0 - 140 0 - 140 0 - 120 0 - 120 -15 - 140 -15 - 140 -15 - 140 -15 - 140 -15 - 140 -15 - 140<br />

MEMBRANE MEMBRANE REINFORCED REINFORCED REINFORCED & REINFORCED & REINFORCED & REINFORCED & REINFORCED & REINFORCED &<br />

OR COATED OR COATED MEMBRANE / MEMBRANE / UNREINFORCED UNREINFORCED UNREINFORCED UNREINFORCED UNREINFORCED UNREINFORCED<br />

METAL METAL COATED METAL COATED METAL EP MEMBRANE EP MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE<br />

CONT ADHES CONT ADHES HOT AIR WELD HOT AIR WELD CONT ADHES CONT ADHES CONT ADHES CONT ADHES ADHESIVE ADHESIVE<br />

OR HOT AIR OR HOT AIR OR OR AND AND OR OR OR OR<br />

WELD WELD ADHESIVE ADHESIVE HEAT WELD HEAT WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD<br />

YES YES YES YES YES YES YES YES YES YES<br />

1992 1992 2000 2000 1999 1999<br />

1995 1995 1999 1999 1992 1992 2000 2000 1999 1999<br />

MILLIONS MILLIONS<br />

MILLIONS MILLIONS THOUSANDS THOUSANDS MILLIONS MILLIONS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

JEANNETTE, PA JEANNETTE, PA PAWTUCKET, RI PAWTUCKET, RI WESTFIELD, NC WESTFIELD, NC WESTFIELD, NC WESTFIELD, NC WESTFIELD, NC WESTFIELD, NC<br />

DISTRIBUTORS DISTRIBUTORS DIST/DIRECT DIST/DIRECT DIST/DIRECT DIST/DIRECT' DIST/DIRECT' DIST/DIRECT' DIST/DIRECT' DIST/DIRECT'<br />

8 8 5 5 125 125 125 125 125 125<br />

YES YES YES YES YES YES YES YES YES YES<br />

800/443-4272 800/443-4272 REGIONAL REGIONAL R. DUKLOS R. DUKLOS R. DUKLOS R. DUKLOS R. DUKLOS R. DUKLOS<br />

OFFICE OFFICE 800/621-ROOF 800/621-ROOF 800/621-ROOF 800/621-ROOF 800/621-ROOF 800/621-ROOF<br />

800/443-4272 800/443-4272 GUARANTEE GUARANTEE TECH DEPT TECH DEPT TECH DEPT TECH DEPT TECH DEPT TECH DEPT<br />

SERVICES SERVICES 800/621-ROOF 800/621-ROOF 800/621-ROOF 800/621-ROOF 800/621-ROOF 800/621-ROOF<br />

X X X X X X<br />

331


TPO Part 2: Test Results<br />

Test description as specified in Draft ASTM Standard<br />

1. COMPANY NAME CARLISLE FIRESTONE FIRESTONE GAF<br />

SYNTEC INC. BUILDING BUILDING MATERIALS<br />

PRODUCTS PRODUCTS CORP.<br />

2. PRODUCT NAME SURE-WELD ULTRA PLY ULTRA PLY EVERGUARD<br />

TYPE/CLASS<br />

& SURE- 45 MIL 60 MIL TPOSR-45<br />

WELD GSD<br />

3A. Type I (Sheets with internal fabric or scrim)<br />

Class P (polypropylene) X X X X<br />

Class E (polyethylene)<br />

Class O (other olefinic materials)<br />

3B. Type II (Sheets with fibers incorporated in<strong>to</strong> production process)<br />

Class P (polypropylene)<br />

Class E (polyethylene)<br />

Class O (other olefinic materials)<br />

4. PHYSICAL PROPERTIES<br />

Thickness:<br />

Overall, minimum, inches (ASTM D751) 0.040 / 0.054 0.046 0.055 0.045<br />

Coating over scrim, minimum, inches (ASTM D751) Type II: NA 0.015 0.018 0.024<br />

Tensile strength (ASM D412, Die C):<br />

Machine direction, minimum, psi<br />

Type I: NA<br />

Cross direction, minimum, psi<br />

Type I: NA<br />

Breaking strength, minimum, lbf Type II: NA 225 350 350 279<br />

Elongation, ultimate, minimum, % (ASTM D751, Grab Method) Type I: NA<br />

Elongation at break, minimum, % (ASTM D751, Grab Method) Type II: NA 25 30 30 29<br />

Tensile set, maximum, % (ASTM D412, Method A, Die C) Type I: NA<br />

Tear Strength, minimum, lbf/inch (ASTM D624, Die C)<br />

Type I: NA<br />

Tear Strength, minimum, lbf (ASTM D751, Procedure B) Type II: NA 55 86 86 90<br />

Brittleness point, maximum ºF (ASTM D2137) -40 -60 -60 -45<br />

Ozone resistance, no cracks (ASTM D1149) PASS PASS PASS PASS<br />

Properties after heat aging (retained values) (ASTM D573):<br />

Tensile strength , % minimum<br />

Type I: NA<br />

Breaking strength, % minimum Type II: NA 225 360 360 >95<br />

Elongation, ultimate, % minimum<br />

Type I: NA<br />

Elongation at break, % minimum Type II: NA 25 30 30 >95<br />

Tear strength, % minimum<br />

Type I: NA<br />

Tearing strength, % minimum Type II: NA 55 90 90<br />

Weight change (mass), maximum %<br />

Linear dimensional change, maximum, % (ASTM D1204) -1.0 0.15 0.15 0.3<br />

Water absorption, maximum, mass % (ASTM D471 for 166<br />

hours at 158 ºF)<br />

Fac<strong>to</strong>ry seam strength, minimum, lbf/inch (ASTM D751, Grab<br />

Method)<br />

4.0 1.5 1.5 1.5<br />

NA 110 110<br />

Weather resistance (Practice G154 or G155):<br />

Visual inspection (Pass/Fail) PASS PASS PASS PASS<br />

Tensile strength, % minimum<br />

Type I: NA<br />

Breaking strength, % minimum Type II: NA 225<br />

Elongation, ultimate, % minimum Type I: NA<br />

Elongation at break, minimum, % Type II: NA 25<br />

5. SEE APPENDIX IF CHECKED X<br />

NA=not applicable<br />

332


TPO Part 2: Test Results<br />

Test description as specified in Draft ASTM Standard<br />

GAF GENFLEX GENFLEX JOHNS JOHNS STEVENS STEVENS STEVENS STEVENS STEVENS<br />

MATERIALS ROOFING ROOFING MANVILLE MANVILLE ROOFING ROOFING ROOFING ROOFING ROOFING<br />

CORP. SYSTEMS SYSTEMS CORP. CORP. SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS<br />

EVERGUARD .045 TPO .060 TPO ULTRAGARD ULTRAGARD EP 0.045 EP 0.060 EP-B EP-B STEVENS<br />

TPOSR-60 SRT-45 SRT-60 0.045 0.060 EP FLEECE<br />

0.80<br />

X X X X X X X X X X<br />

0.060 0.040 0.054 0.40 0.40 0.043 0.057 0.043 0.057 0.080<br />

0.012 0.012 0.018 - 0.020 0.027 - 0.030 0.013 0.020 0.013 0.020 0.013<br />

303 225 225 300 300 310 350 310 350 310<br />

22 15 15 20 20 20 20 20<br />

90 55 55 90 90 135 135 135 135 135<br />

-45 -40 -40 -40 -40 -40 -40 -40 -40 -40<br />

PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS<br />

>95 100 100 95 95 275 315 275 310 275<br />

>95 100 100 95 95 18 18 18 18 18<br />

100 100 95 95 120 120 120 120 120<br />

1 1


TPO Part 2: Test Results<br />

Test description as specified in Draft ASTM Standard<br />

1. COMPANY NAME STEVENS<br />

ROOFING<br />

SYSTEMS<br />

2. PRODUCT NAME STEVENS<br />

TYPE/CLASS<br />

EP FLEECE<br />

0.085<br />

3A. Type I (Sheets with internal fabric or scrim)<br />

Class P (polypropylene)<br />

X<br />

Class E (polyethylene)<br />

Class O (other olefinic materials)<br />

3B. Type II (Sheets with fibers incorporated in<strong>to</strong> production process)<br />

Class P (polypropylene)<br />

Class E (polyethylene)<br />

Class O (other olefinic materials)<br />

4. PHYSICAL PROPERTIES<br />

Thickness:<br />

Overall, minimum, inches (ASTM D751) 0.095<br />

Coating over scrim, minimum, inches (ASTM D751) 0.020<br />

Tensile strength (ASM D412, Die C):<br />

Machine direction, minimum, psi<br />

Cross direction, minimum, psi<br />

Breaking strength, minimum, lbf 350<br />

Elongation, ultimate, minimum, % (ASTM D751, Grab Method)<br />

Elongation at break, minimum, % (ASTM D751, Grab Method) 20<br />

Tensile set, maximum, % (ASTM D412, Method A, Die C)<br />

Tear Strength, minimum, lbf/inch (ASTM D624, Die C)<br />

Tear Strength, minimum, lbf (ASTM D751, Procedure B) 135<br />

Brittleness point, maximum ºF (ASTM D2137) -40<br />

Ozone resistance, no cracks (ASTM D1149)<br />

PASS<br />

Properties after heat aging (retained values) (ASTM D573):<br />

Tensile strength , % minimum<br />

Breaking strength, % minimum 310<br />

Elongation, ultimate, % minimum<br />

Elongation at break, % minimum 18<br />

Tear strength, % minimum<br />

Tearing strength, % minimum 120<br />

Weight change (mass), maximum %<br />

Linear dimensional change, maximum, % (ASTM D1204) 0.5<br />

Water absorption, maximum, mass % (ASTM D471 for 166<br />

hours at 158 ºF)<br />

Fac<strong>to</strong>ry seam strength, minimum, lbf/inch (ASTM D751, Grab<br />

Method)<br />

2<br />

75% OF SHEET<br />

STRENGTH<br />

Weather resistance (Practice G154 or G155):<br />

Visual inspection (Pass/Fail)<br />

PASS<br />

Tensile strength, % minimum<br />

Breaking strength, % minimum 90<br />

Elongation, ultimate, % minimum<br />

Elongation at break, minimum, % 90<br />

5. SEE APPENDIX IF CHECKED X<br />

NA=not applicable<br />

334


Other Prefabricated Sheet-Applied Membranes Part 1: General Information<br />

1. COMPANY NAME BONDCOTE BONDCOTE BONDCOTE BONDCOTE CARLISLE COOLEY<br />

ROOFING ROOFING ROOFING ROOFING SYNTEC ENGINEERED<br />

SYSTEMS SYSTEMS SYSTEMS SYSTEMS INC. MEMBRANE<br />

2. PRODUCT NAME BONDCOTE BONDCOTE BONDCOTE BONDCOTE SURE-SEAL C3<br />

350 SERIES 400 SERIES 500 SERIES FLEECEBOND POLYEPICHLO-<br />

3. PRODUCT DESCRIPTION<br />

1000 ROHYDRIN<br />

Reinforcement 18 X 12 18 X 12 18 X 12 18 X 12 NONE POLYESTER<br />

POLYESTER POLYESTER POLYESTER POLYESTER<br />

Color WHITE WHITE WHITE WHITE GRAY/<br />

Installed Weight (lbs./ft 2 w/o ballast)` 0.24 0.28 0.33 0.30 0.48<br />

4. COATING REQUIRED: NONE NONE NONE NONE NONE NONE<br />

5. USE IN:<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD HEAT WELD HEAT WELD HEAT WELD HEAT WELD CONTACT HOT AIR<br />

7. TYPES OF ROOF SYSTEMS<br />

BLACK<br />

ADHESIVE<br />

Loose Laid/Ballasted(ballast: lbs./ft 2 ) 10 10 10 10 10<br />

Partially Adhered (method) MECHANICALLY MECHANICALLY MECHANICALLY MECHANICALLY MECHANICALLY<br />

Fully Adhered(method) CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X X<br />

8. MINIMUM SLOPE REQUIRED (inches per foot) DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL 1/4" LEVEL<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber X O X O X O X X<br />

Mineral Fiber X O X O X O X O O<br />

Polystyrene S O S O S O X O X<br />

Cellular Glass X X X X X O<br />

Phenolic<br />

Fiberboard X X X X X X<br />

Perlite X X X X O O<br />

Polyisocyanurate X X X X X X<br />

Polyurethane X X X X X X<br />

Gypsum X X X X X O X<br />

Concrete O O O X X O O<br />

Wood Plank O O O X X O X<br />

Plywood O O O X X O X<br />

Existing Built-up Membrane O O O X X O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 0 – 180 0 – 180 0 – 180 0 – 180 -20 - 180 40 – 120<br />

12. FLASHING MATERIAL ROOF MEMB ROOF MEMB ROOF MEMB ROOF MEMB UNCURED OR C3, RAM,<br />

NBP-COATED NBP-COATED NBP-COATED NBP-COATED CURED EPDM C3-COATED<br />

METAL METAL METAL METAL & ECO/CO METAL<br />

13. FLASHING METHOD HEAT WELD & HEAT WELD & HEAT WELD & HEAT WELD & CONTACT HOT AIR<br />

CONTACT CONTACT CONTACT CONTACT ADHESIVE<br />

ADHESIVE ADHESIVE ADHESIVE ADHESIVE<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES NONE YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA 1987 1977<br />

Within USA 1977 1977 1995 1991 1977 1988<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS >1,000,000<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DIRECT DIRECT DIRECT DIRECT DISTRS.DIRECTT<br />

19. NUMBER OF REGIONAL LOCATIONS 4 4 4 4 70 10<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: SALES DEPT. SALES DEPT. SALES DEPT. SALES DEPT. C. KUHL J. SMITH<br />

800/368–2160 800/368–2160 800/368–2160 800/368–2160 717/245-7000<br />

22. TECHNICAL INFORMATION, CONTACT: TECH. DEPT. TECH. DEPT. TECH. DEPT. TECH. DEPT. S. IBRAHIM T. SAILLANT<br />

800/368–2160 800/368–2160 800/368–2160 800/368–2160 717/245-7000<br />

23. SEE APPENDIX IF CHECKED X X X X<br />

X<br />

336


Other Prefabricated Sheet-Applied Membranes Part 1: General Information<br />

COOLEY COOLEY DURO-LAST DURO-LAST ECOLOGY ERSYSTEMS ERSYSTEMS FLEX FLEX FLEX<br />

ENGINEERED ENGINEERED INC. INC. ROOF MEMBRANE MEMBRANE MEMBRANE<br />

MEMBRANE MEMBRANE SYSTEMS INTERNATIONAL INTERNATIONAL INTERNATIONAL<br />

RAM C3 - TPO DURO-LAST DURO-LAST ERS 900 PERMAWELD PERMAWELD FLEX FLEX FLEX<br />

40 MIL 50 MIL FLEECE-BACKED FB 100 FB ELVALOY MF/R ELVALOY<br />

WOVEN & POLYESTER REINFORCED REINFORCED POLYESTER CPA MEMBRANE CPA REINFORCED REINFORCED REINFORCED<br />

NONWOVEN POLYESTER POLYESTER REINFOR W/FLEECE POLYESTER POLYESTER W/ POLYESTEER W/ POLYESTER<br />

POLYESTER BACK POLY FAB REINFORCED FLEECE BACKING FLEECE BACKING<br />

WHITE / TAN / WHITE & WHITE / TAN / WHITE / TAN / GRAY BLACK WHITE WHITE WHITE / WHITE / WHITE /<br />

GRAY BLACK GRAY GRAY OFF-WHITE OFF-WHITE OFF-WHITE<br />

0.030 NOM. 0.25 0.3O 0.40 0.4 0.33 0.44 0.35 0.30<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

HOT AIR HOT AIR HEAT WELD HEAT WELD HEAT WELD HEAT WELD OR HEAT WELD HOT AIR WELD HOT AIR WELD HOT AIR WELD<br />

SOLVENT WELD<br />

10 10 10 10 10 10 MIN 10 MIN 10 MIN<br />

MECHANICALLY MECHANICALLY MECHANICALLY MECH. FAST. MECHANICALLY MECH. FAST. MECH. FAST. MECH. FAST.<br />

CONT. ADHES. BITUMEN HOT AS./CLD AD. COLD ADHES HOT AS./CLD AD. HOT AS./CLD AD. CONT. ADHES.<br />

X X X X X X X X X X<br />

LEVEL LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL<br />

X X X X O X X X X X<br />

O X X X O X X X O X<br />

O X S S O X O X O X O X S O<br />

O X X X O O O X X X O<br />

X O O O X X<br />

X X X O X X X X X<br />

O X X O X X X X X O<br />

X X X X O X X X X O X O<br />

X X S S O X X X O X O<br />

O X X X O X X X X O X O<br />

O X X X O X O X O X X S<br />

O X X X O X X X X O O<br />

O X X X O X X X X O X O<br />

O X S O S O O S O S O X X O X O<br />

NONE N/A NONE NONE NONE NONE NONE NONE NONE NONE<br />

40 – 120 40 -120 –30 – 120 –30 – 120 40 - 120 –30 – 160 –30 – 160 0 – 120 0 – 120 0 – 120<br />

C3, RAM, REINFORCED SAME SAME SAME ROOF ROOF ROOF ROOF ROOF<br />

C3-COATED & NON- MATERIAL MATERIAL MATERIAL MEMBRANE / MEMBRANE / MEMBRANE / MEMBRANE / MEMBRANE /<br />

METAL REINFORCED COATED METAL COATED METAL COATED METAL COATED METAL COATED METAL<br />

HOT AIR & HOT AIR / HEAT WELD HEAT WELD SELF ADHERED HEAT WELD HEAT WELD HOT AIR HOT AIR HOT AIR<br />

BONDING ADHESIVE W/HEAT WELD OR OR WELD WELD WELD<br />

ADHESIVE WALL MASTIC WALL MASTIC OR ADHESIVE OR ADHESIVE OR ADHESIVE<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA USA USA USA USA USA USA USA USA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1997<br />

1990 1997 1978 1988 1+99 1994 1984 1988 1988 1988<br />

THOUSANDS THOUSANDS<br />

>1,000,000 >1,000,000 >1,000,000 THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

DIRECT DIRECT DIRECT DISTRS, DIRECT DISTRS, DIRECT DIRECT DIRECT DIRECT<br />

10 4 4 20 14 14 4 4<br />

YES YES YES YES YES YES YES YES YES<br />

J. SMITH J. SMITH SALES DEPT. SALES DEPT. E. NELSON T. LEONARD T. LEONARD J. DOYLE J. DOYLE J. DOYLE<br />

800/248–0280 800/248–0280 800/403-7747 800/403–7747 610/286–7788 610/286–7788 610/286–7788<br />

T. SAILLANT T. SAILLANT ENGR. DEPT. ENGR. DEPT. B. PFIEFER J. LEONARD R. BAKER M GIANGIACOMO M GIANGIACOMO M GIANGIACOMO<br />

800/248–0280 800/248–0280 800/403-7747 800/403–7747 610/286–7788 610/286–7788 610/286–7788<br />

X X X<br />

337


Other Prefabricated Sheet-Applied Membranes Part 1: General Information<br />

1. COMPANY NAME GENFLEX GENFLEX HYLOAD, HYLOAD, HYLOAD, HYLOAD,<br />

ROOFING ROOFING INC. INC. INC. INC.<br />

SYSTEMS<br />

SYSTEMS<br />

2. PRODUCT NAME GENFLEX GENFLEX HYLOAD HYLOAD HYLOAD HYLOAD<br />

.045 TPO .060 TPO 150 E 250 E WS SAM<br />

3. PRODUCT DESCRIPTION<br />

Reinforcement POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

Color WHITE / BLACK / WHITE / BLACK / BLACK BLACK BLACK BLACK<br />

GRAY<br />

Installed Weight (lbs./ft 2 w/o ballast)` 0.21 0.29 0.40 0.40 0.50 0.40<br />

4. COATING REQUIRED: NONE NONE NONE NONE NONE NONE<br />

5. USE IN:<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD HOT AIR WELD HOT AIR WELD HEAT WELD HEAT WELD HEAT WELD SELF-ADHERED<br />

7. TYPES OF ROOF SYSTEMS<br />

GRAY<br />

Loose Laid/Ballasted(ballast: lbs./ft 2 ) 10 10<br />

Partially Adhered (method) MECH. FAST. MECH. FAST.<br />

OR MOPPED<br />

Fully Adhered(method) CONT. ADHES. CONT. ADHES. BITUMEN CONT. ADHES SELF-ADHERED SELF-ADHERED<br />

Protected <strong>Roof</strong> Membrane Assembly X X X X X<br />

8. MINIMUM SLOPE REQUIRED (inches per foot) LEVEL LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber O O O O O O<br />

Mineral Fiber X O X O O O O O<br />

Polystyrene O X O X O O O O<br />

Cellular Glass X X O O O O<br />

Phenolic O O O O<br />

Fiberboard X X O O O O<br />

Perlite X X O O O O<br />

Polyisocyanurate X X O O O O<br />

Polyurethane X X O O O O<br />

Gypsum X X O O O O<br />

Concrete O X O X O O O O<br />

Wood Plank O S O S O O O O<br />

Plywood O S O S O O O O<br />

Existing Built-up Membrane O O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 0 – 140 0 – 140 40 - 120 40 - 120 40 - 120 40 - 120<br />

12. FLASHING MATERIAL MEMBRANE MEMBRANE HYLOAD 150 E HYLOAD WS HYLOAD WS HYLOAD SAM<br />

OR COATED OR COATED HYLOAD SAM STRAPPED STRAPPED STRAPPED<br />

METAL METAL WS STRAP<br />

13. FLASHING METHOD CONT. ADHES. CONT. ADHES. SELF-ADHERED SELF-ADHERED SELF-ADHERED SELF-ADHERED<br />

OR HOT AIR OR HOT AIR WITH HEAT WITH HEAT WITH HEAT STRAPPED<br />

WELD WELD WELD WELD WELD<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA<br />

Within USA 1995 1995 1969 1977 1985 1985<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA MILLIONS MILLIONS >MILLIONS THOUSANDS THOUSANDS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRIBUTORS DISTRIBUTORS DIRECT DIRECT DIRECT DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 8 8 20 20 20 20<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: SALES DEPT. SALES DEPT. J.NUSSBAUM J.NUSSBAUM J.NUSSBAUM J.NUSSBAUM<br />

800/443-4272 800/443-4272 800/457-4056 800/457-4056 800/457-4056 800/457-4056<br />

22. TECHNICAL INFORMATION, CONTACT: TECH. DEPT. TECH. DEPT. HYLOAD HYLOAD HYLOAD HYLOAD<br />

23. SEE APPENDIX IF CHECKED<br />

800/443-4272 800/443-4272 800/457-4056 800/457-4056 800/457-4056 800/457-4056<br />

338


Other Prefabricated Sheet-Applied Membranes Part 1: General Information<br />

HYLOAD, HYLOAD, HYLOAD, HYLOAD, HYLOAD , HYLOAD, INTERCONTINENTAL INTERCONTINENTAL INTERCONTINENTAL INTERCONTINENTAL<br />

INC. INC. INC. INC. INC. INC. COATINGS CORP. COATINGS CORP COATINGS CORP. COATINGS CORP.<br />

(I-CON) (I-CON) (I-CON) (I-CON)<br />

HYBASE HYBASE HYBASE HYLOAD ALPSAM APSAM ROOFTEC ROOF TEC ROOFTEC ROOFTEC<br />

SAM SAM VR SAM URWS PMVB WS HA CA WS SA<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

BLACK BLACK BLACK BLACK WHITE WHITE BLACK BLACK BLACK BLACK<br />

0.30 0.30 0.40 0.70 0.40 0.40 0.40 0.40 0.50 0.40<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

X X X X X X X X<br />

X X X X X X X X<br />

SELF-ADHERED SELF-ADHERED HEAT WELD SELF-ADHERED HEAT WELD SELF-ADHERD HEAT WELD HEAT WELD HEAT WELD SELF-ADHERED<br />

OR BITUMEN<br />

SELF-ADHERED SELF-ADHERED SELF-ADHERED SELF-ADHERED SELF-ADHERED SELF-ADHERD BITUMEN CONT. ADHES. SELF-ADHERED SELF-ADHERED<br />

X X X<br />

DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL 1 1 DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O O O O O O O O<br />

O O O X O O O O O O O<br />

O O O X O O O O O O O<br />

O O O X O O O O O O O<br />

O O O X O O O O O O O<br />

O O O O O O O O O<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

40 - 120 40 - 120 40 - 120 40 - 120 40 - 120 40 - 120 40 – 120 40 – 120 40 – 120 40 - 120<br />

HYBASE HYBASE HYBASE HYLOAD ALPSAM WS ALPSAM ROOF TEC HA ROOFTEC WS ROOFTEC WS ROOFTEC SA<br />

SAM SAM VR SAM URWS PMVB STRAPPED STRAPPED SA & WS STRAPPED STRAPPED STRAPPED<br />

STRAPPED STRAPPED STRAPPED<br />

SELF-ADHERED SELF-ADHERED SELF-ADHERED SELF-ADHERED SELF-ADHERED SELF-ADHERD SELF-ADHERING SELF-ADHERING SELF-ADHERING SELF-ADHERED<br />

STRAPPED STRAPPED WITH WITH WITH STRPPED<br />

HEAT WELD HEAT WELD HEAT WELD<br />

YES YES YES YES YES YES YES YES YES YES<br />

USA USA USA USA USA USE USA USA USA USA<br />

USA USA USA USA USA USE USA USA USA USA<br />

1985 1985 1989 1989 1989 1989 1969 1977 1985 1985<br />

THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS > 1 MILLION THOUSANDS THOUSANDS THOUSANDS<br />

DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT<br />

20 20 20 20 20 20 18 18 18 18<br />

YES YES YES YES YES YES YES YES YES YES<br />

J.NUSSBAUM J.NUSSBAUM J.NUSSBAUM J.NUSSBAUM J.NUSSBAUM J.NUSSBAUM RON CASPER RON CASPER RON CASPER RON CASPER<br />

800/457-4056 800/457-4056 800/457-4056 800/457-4056 800/457-4056 800/457-4056 888/881-1426 888/881-1426 888/881-1426 888/881-1426<br />

HYLOAD HYLOAD HYLOAD HYLOAD HYLOAD HYLOAD RON CASPER RON CASPER RON CASPER RON CASPER<br />

800/457-4056 800/457-4056 800/457-4056 800/457-4056 800/457-4056 800/457-4056 888/881-1426 888/881-1426 888/881-1426 888/881-1426<br />

X X X X<br />

339


Other Prefabricated Sheet-Applied Membranes Part 1: General Information<br />

1. COMPANY NAME INTERCONTINENTAL INTERCONTINENTAL INTERCONTINENTAL INTERCONTINENTAL INTERCONTINENTAL INTERCONTINENTAL<br />

COATINGS CORP. COATINGS CORP. COATINGS CORP. COATINGS CORP. COATINGS CORP. COATINGS CORP.<br />

(I-CON) (I-CON) (I-CON) (I-CON) (I-CON) (I-CON)<br />

2. PRODUCT NAME SA ROOFTEC ROOFTEC ROOFTEC SA ROOFTEC SA ROOFTEC SA ROOFTEC<br />

SAB SABV SABVWS SAPM SAW SAWWS<br />

3. PRODUCT DESCRIPTION<br />

Reinforcement POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

Color BLACK BLACK BLACK BLACK WHITE WHITE<br />

FLEECE BAC<br />

Installed Weight (lbs./ft 2 w/o ballast)` 0.30 0.30 0.40 0.70 0.40 0.40<br />

4. COATING REQUIRED: NONE NONE NONE NONE NONE NONE<br />

5. USE IN:<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing X X X X X X<br />

6. FIELD LAP JOINT METHOD SELF-ADHERED SELF-ADHERED HEAT WELD SELF-ADHERED SELF-ADHERED HEAT WELD<br />

7. TYPES OF ROOF SYSTEMS<br />

Loose Laid/Ballasted(ballast: lbs./ft 2 )<br />

Partially Adhered (method)<br />

Fully Adhered(method) SELF-ADHERED SELF-ADHERED SELF-ADHERED SELF-ADHERED SELF-ADHERED SELF-ADHERED<br />

Protected <strong>Roof</strong> Membrane Assembly X X<br />

8. MINIMUM SLOPE REQUIRED (inches per foot) DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL 1 1<br />

9. ACCEPTABLE SUBSTRATES<br />

(X=direct application permitted)<br />

(S=separa<strong>to</strong>r sheet required)<br />

(O=overlayment required in some or all circumstances)<br />

Glass Fiber O O O O O O<br />

Mineral Fiber O O O O O O<br />

Polystyrene O O O O O O<br />

Cellular Glass O O O O O O<br />

Phenolic O O O O O O<br />

Fiberboard O O O O O O<br />

Perlite O O O O O<br />

Polyisocyanurate O O O O O O<br />

Polyurethane O O O O O O<br />

Gypsum O O O X O O O<br />

Concrete O O O X O O O<br />

Wood Plank O O O X O O O<br />

Plywood O O O X O O O<br />

Existing Built-up Membrane O O O O O<br />

10. RESTRICTED REGIONS (refer <strong>to</strong> manufacturer's literature) NONE NONE NONE<br />

11. WORKABLE TEMPERATURE RANGE (degrees F) 40 -120 40 – 120 40 – 120<br />

12. FLASHING MATERIAL ROOFTEC ROOFTEC ROOFTEC ROOFTEC ROOFTEC ROOFTEC<br />

SAB SABV SABVWS SAPM SAW SAWWS<br />

STRAPPED STRAPPED STRAPPED STRAPPED<br />

13. FLASHING METHOD SELF-ADHERING SELF-ADHERING SELF-ADHERING SELF-ADHERING SELF-ADHERING SELF-ADHERING<br />

STRAPPED STRAPPED WITH<br />

HEAT WELD<br />

14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES YES<br />

15. COUNTRY OF:<br />

Origin USA USA USA USA USA USA<br />

Manufacture USA USA USA USA USA USA<br />

16. YEAR OF FIRST COMMERCIAL USE<br />

Outside USA<br />

Within USA 1985 1985 1989 1989 1989 1989<br />

17. NUMBER OF SQUARES INSTALLED (100 ft 2 )<br />

Outside USA<br />

Within USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS<br />

18. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT<br />

19. NUMBER OF REGIONAL LOCATIONS 18 18 18 18 18 18<br />

20. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES<br />

21. SALES INFORMATION, CONTACT: RON CASPER RON CASPER RON CASPER RON CASPER RON CASPER RON CASPER<br />

888/881-1426 888/881-1426 888/881-1426 888/881-1426 888/881-1426 888/881-1426<br />

22. TECHNICAL INFORMATION, CONTACT: RON CASPER RON CASPER RON CASPER RON CASPER RON CASPER RON CASPER<br />

888/881-1426 888/881-1426 888/881-1426 888/881-1426 888/881-1426 888/881-1426<br />

23. SEE APPENDIX IF CHECKED X X X X X X<br />

340


Other Prefabricated Sheet-Applied Membranes Part 1: General Information<br />

SEAMAN SEAMAN VERSICO, VERSICO,<br />

CORP. CORP. INC. INC.<br />

FIBERTITE FB FIBERTITE VERSIWELD VERSIWELD<br />

PREMIER PREMIER EF<br />

REINFORCED REINFORCED<br />

POLYESTER W/ POLYESTER<br />

FLEECE BACKING<br />

LIGHT BEIGE LIGHT BEIGE WHITE, GRAY OR WHITE, GRAY OR<br />

TAN ON BLACK TAN ON BLACK<br />

< 0.28 < 0.25 0.25 0.25<br />

NONE NONE NONE NONE<br />

X X X X<br />

X X X X<br />

HEAT WELD HEAT WELD HEAT WELD HEAT WELD<br />

10 MIN<br />

BONDING ADHS. MECH. FAST. MECH. FAST.<br />

ADHESIVE BONDING ADHS. CONT. ADHES. CONT. ADHES.<br />

X X<br />

NONE NONE NONE NONE<br />

X<br />

X<br />

X O O<br />

O X S O O O<br />

O X S O X X<br />

X<br />

X X X<br />

O X O O<br />

X X X X<br />

X O X X X<br />

X O X O X O X O<br />

X O S X O X O<br />

X O S X O X O<br />

X O X S O X O X O<br />

X O X S O X O X O<br />

NONE NONE NONE NONE<br />

0 – 120 –30 – NO LIMIT –25 – 180 –25 – 180<br />

ROOF ROOF VERSIWELD VERSIWELD<br />

MEMBRANE MEMBRANE FLASHING OR FLASHING OR<br />

COATED METAL COATED METAL COATED METAL COATED METAL<br />

HEAT WELD, HEAT WELD, CONTACT CONTACT<br />

WALL MASTIC WALL MASTIC ADHESIVE & ADHESIVE &<br />

OR ADHESIVE OR ADHESIVE HEAT WELD HEAT WELD<br />

YES YES YES YES<br />

USA USA USA USA<br />

USA USA USA USA<br />

1995 1982<br />

1994 1978 1991 1991<br />

THOUSANDS THOUSANDS<br />

THOUSANDS >1,000,000 MILLIONS MILLIONS<br />

DIRECT DIRECT DISTRIBUTORS DISTRIBUTORS<br />

20 20 125 125<br />

YES YES YES YES<br />

800/927-8578 800/927-8578 M. MCAULEY M. MCAULEY<br />

800/992–7663 800/992–7663<br />

800/927-8578 800/927-8578 R, GIANGIULI R, GIANGIULI<br />

800/992–7663 800/992–7663<br />

X<br />

X<br />

341


Other Prefabricated Sheet-Applied Membranes Part 2: Test Results<br />

1. COMPANY NAME BONDCOTE ROOFING SYSTEMS BONDCOTE ROOFING SYSTEMS BONDCOTE ROOFING SYSTEMS BONDCOTE ROOFING SYSTEMS<br />

2. PRODUCT NAME BONDCOTE 350 SERIES BONDCOTE 400 SERIES BONDCOTE 500 SERIES BONDCOTE FLEECEBOND 1000<br />

3. PRODUCT DESCRIPTION ACRYLONITRILE BUTADIENE POLYMER BLEND (NBP) ACRYLONITRILE BUTADIENE ACRYLONITRILE BUTADIENE<br />

POLYMER BLEND (NBP) POLYMER BLEND (NBP) POLYMER BLEND (NBP)<br />

4. THICKNESS METHOD ASTM D 751 ASTM D 751 ASTM D 751 ASTM D 751<br />

RESULTS 35 MILS 40 MILS 50 MILS 100 MILS<br />

5. TENSILE STRENGTH METHOD ASTM D 751 GRAB METHOD ASTM D 751 GRAB METHOD ASTM D 751 GRAB METHOD ASTM D 751 GRAB METHOD<br />

ASTM D 882 ASTM D 882 ASTM D 882 ASTM D 882<br />

RESULTS 390 X 300 LBS. 390 X 300 LBS. 450 X 330 LBS. 390 X 300 LBS.<br />

6000 PSI 6000 PSI 7500 PSI 6000 PSI<br />

6. LAP JOINT METHOD METHOD ASTM D 751 ASTM D 751 ASTM D 751 ASTM D 751<br />

RESULTS EXCEED PRODUCT STRENGTH EXCEED PRODUCT STRENGTH EXCEED PRODUCT STRENGTH EXCEED PRODUCT STRENGTH<br />

7. ELONGATION AT BREAK METHOD ASTM D 751 ASTM D 751 ASTM D 751 ASTM D 751<br />

RESULTS 30 X 35% 30 X 35% 30 X 35% 30 X 35%<br />

8. TENSILE SET METHOD<br />

RESULTS<br />

9. LOW TEMPERATURE METHOD ASTM D 2136 ASTM D 2136 ASTM D 2136 ASTM D 2136<br />

FLEXIBILITY<br />

RESULTS –40 F, NO CRACKS –40 F, NO CRACKS –40 F, NO CRACKS –40 F, NO CRACKS<br />

10. WATER ABSORPTION METHOD ASTM D 570 ASTM D 570 ASTM D 570 ASTM D 570<br />

RESULTS 95% OF BREAKING STRENGTH<br />

>90% OF ELONGATION >90% OF ELONGATION >90% OF ELONGATION<br />

13. OZONE RESISTANCE METHOD ASTM D 1149, 100 PPHM, 104 F, ASTM D 1149, 100 PPHM, 104 F, ASTM D 1149, 100 PPHM, 104 F, ASTM D 1149, 100 PPHM, 104 F,<br />

1/8" BENT LOOP 1/8" BENT LOOP 1/8" BENT LOOP 1/8" BENT LOOP<br />

RESULTS NO CRACKS, NO CRACKS, NO CRACKS, NO CRACKS,<br />

7X MAGNIFICATION 7X MAGNIFICATION 7X MAGNIFICATION 7X MAGNIFICATION<br />

14. RESISTANCE TO METHOD FS191, METHOD 5804, CARBON FS191, METHOD 5804, CARBON FS191, METHOD 5804, CARBON FS191, METHOD 5804, CARBON<br />

ACCELERATED ASTM G90 EMMAGUA ASTM G90 EMMAGUA ASTM G90 EMMAGUA ASTM G90 EMMAGUA<br />

WEATHERING RESULTS NO CRACKING, 10,000 HOURS NO CRACKING, 10,000 HOURS NO CRACKING, 10,000 HOURS NO CRACKING, 10,000 HOURS<br />

4,000,000 LANGLEYS 4,000,000 LANGLEYS 4,000,000 LANGLEYS 4,000,000 LANGLEYS<br />

15. DYNAMIC IMPACTING METHOD FS 1018, METHOD 2031 FS 1018, METHOD 2031 FS 1018, METHOD 2031 FS #1018 METHOD 2031<br />

(PUNCTURING)<br />

RESULTS 290 LBS. 290 LBS. 325 LBS. 290 LBS.<br />

16 TEAR RESISTANCE METHOD<br />

RESULTS<br />

17. TEARING STRENGTH METHOD ASTM D 751 ASTM D 751 ASTM D 751 ASTM D 751<br />

8 IN. X 10 IN. SAMPLE 8 IN. X 10 IN. SAMPLE 8 IN. X 10 IN. SAMPLE 8 IN. X 10 IN. SAMPLE<br />

RESULTS 120 X 110 LBS. 125 X 115 LBS. 130 X 120 LBS. 125 X 115 LBS.<br />

18. LOW TEMPERATURE METHOD<br />

IMPACT<br />

RESULTS<br />

19. PERMEABILITY METHOD ASTM E 96, METHOD A ASTM E 96, METHOD A ASTM E 96, METHOD A ASTM E 96, METHOD A<br />

RESULTS 0.22 US PERMS 0.22 US PERMS 0.22 US PERMS 0.22 US PERMS<br />

20. DIMENSIONAL CHANGE METHOD ASTM D 1204 ASTM D 1204 ASTM D 1204 ASTM D 1204<br />

AFTER STRESS<br />

RELAXATION RESULTS


Other Prefabricated Sheet-Applied Membranes Part 2: Test Results<br />

CARLISLE SYNTEC INC. COOLEY ENGINEERED MEMBRANE COOLEY ENGINEERED MEMBRANE COOLEY ENGINEERED MEMBRANE DURO-LAST INC.<br />

POLYEPICHLORHYDRIN ECO/CO C3 RAM C3-TPO DURO-LAST 40 MIL<br />

NONREINFORCED TRI-POLYMER ALLOY TRI-POLYMER ALLOY POLYPROPYLENE PVC BLEND REINFORCED<br />

POLYEPICHLORHYDRIN ELVALOY KEE ELVALOY KEE W/POLYESTER FABRIC<br />

ASTM D412 ASTM D 751 ASTM D 751 ASTM D 751 ASTM D 751<br />

60 MIL<br />

±10% 40 MILS 45 MILS 45 40 MILS NOMINAL<br />

ASTM D412 ASTM D 751, GRAB ASTM D 751, GRAB ASTM 7 751 ASTM D 751, GRAB METHOD<br />

ASTM D 882<br />

1500 PSI (MIN) 300 X 300 LBS. 350 X 325 LBS. 300 X 300 435 X 350 LBS.<br />

7200 PSI<br />

ASTM D 638 ASTM D 638 HEAT WELD ASTM D 751<br />

90% 90% 350 LBS. (MIN)<br />

ASTM D412 ASTM D 751 ASTM D 751 ASTM D 751<br />

200% (MIN) 17% X 19% 40% X 30% 35%<br />

ASTM D 746 ASTM D 2136 ASTM D 2136 ASTM D 2136 ASTM D 2136<br />

-20F (MIN) –40 F, PASS –40 F, PASS -40 F –40 F, NO CRACKS<br />

ASTM D 750 ASTM D 750 ASTM D 471<br />

7 DAYS @ 158 F 7 DAYS @ 158 F<br />

1% MAX. 1% MAX. ± 4%<br />

ASTM D 1204<br />


Other Prefabricated Sheet-Applied Membranes Part 2: Test Results<br />

1. COMPANY NAME DURO-LAST INC. ECOLOGY ROOF SYSTEMS ERSYSTEMS ERSYSTEMS<br />

2. PRODUCT NAME DURO-LAST 50 MIL ERS 900 PERMAWELD FLEECE-BACKED PERMAWELD<br />

3. PRODUCT DESCRIPTION PVC BLEND REINFORCED POLYESTER REINFORCED CPA MEMBRANE REINFORCED POLYESTER-REINFORCED CPA<br />

W/POLYESTER FABRIC KEE W/POLYESTER FLEECE FABRIC<br />

4. THICKNESS METHOD ASTM D 751 ASTM 2083 ASTM D 751 ASTM D 751<br />

RESULTS 50 MILS 60 MIL 40 MILS NOM. 40 MIL NOM. AND 48 MIL NOM.<br />

5. TENSILE STRENGTH METHOD ASTM D 751, GRAB METHOD ASTM D 412 ASTM D 882 ASTM D 882<br />

ASTM D 882 ASTM D 751 ASTM D 751<br />

RESULTS 450 X 380 LBS. 1699 LBS. SQ. IN. 300 X 325 LBS. 315 X 325 LBS.<br />

8780 PSI 8000 PSI 7450 PSI<br />

6. LAP JOINT METHOD METHOD ASTM D 751 HEAT WELD ASTM D 751 ASTM D 751<br />

RESULTS 350 LBS. (MIN) > 35O LBS. > 35O LBS.<br />

7. ELONGATION AT BREAK METHOD ASTM D 751 ASTM D 412 ASTM D 751 ASTM D 751<br />

RESULTS 35% 170% 35% 35% X 35%<br />

8. TENSILE SET METHOD<br />

RESULTS<br />

9. LOW TEMPERATURE METHOD ASTM D 2136 CGSB-37-6PS6M ASTM D 2136 ASTM D 2136 –30 F<br />

FLEXIBILITY<br />

RESULTS –40 F, NO CRACKS PASS –40 F, PASS NO CRACKS<br />

10. WATER ABSORPTION METHOD ASTM D 570 @ 70 F ASTM D 750 @ 70 F<br />

@ 122 F 48 HOURS<br />

@122 F 48 HOURS<br />

RESULTS 1.4% > 1%<br />

11. DIMENSIONAL STABILITY METHOD ASTM D 1204 ASTM D 570 ASTM D 570<br />

AFTER WATER<br />


Other Prefabricated Sheet-Applied Membranes Part 2: Test Results<br />

FLEX MEMBRANE INT'L INC. FLEX MEMBRANE INT'L INC. FLEX MEMBRANE INT'L INC. GENFLEX ROOFING SYSTEMS GENFLEX ROOFING SYSTEMS<br />

FLEX FB 100 FLEX FB ELVALOY FLEX MF/R ELVALOY GENFLEX TPO .045 GENFLEX TPO .060<br />

POLYESTER REINFORCED WITH POLYESTER REINFORCED WITH POLYESTER REINFORCED WITH TPO THERMOPLASTIC OLEFIN TPO THERMOPLASTIC OLEFIN<br />

FLEECE, ELVALOY KEE FLEECE, ELVALOY KEE FLEECE, ELVALOY KEE<br />

ASTM D 751 ASTM D 751 ASTM D 751, GRAB ASTM D 751 ASTM D 751<br />

100 MIL NOM. 45 MIL NOM. 40 MIL NOM. 0.045 IN 0.060 IN.<br />

ASTM D 638, PSI ASTM D 751, GRAB ASTM D 751 ASTM D 751 ASTM D 751<br />

MD 1844 > 340 LBS. 235 LBS. 225 LB./F 225 LB./F<br />

TD 2111<br />

ASTM D 638 ASTM D 638 ASTM D 751 HEAT WELD HEAT WELD<br />

> 90% 90 % > 400 LBS.<br />

ASTM D 638, % ASTM D 751 ASTM D 751 ASTM D 412 DIEC ASTM D 412 DIEC<br />

MD 183 > 28% > 28% 500% ULTIMATE 500% ULTIMATE<br />

TD 108<br />

ASTM D 2136 ASTM D 2136 ASTM D 2136 ASTM D 2137 ASTM D 2137<br />

–40 F, PASS –40 F, PASS –40 F, PASS -40 F, PASS -40 F, PASS<br />

ASTM D 0573 ASTM D 570 ASTM D 570 ASTM D 471 ASTM D 471<br />

1.5 % MAX. 1.5% MAX. 1.5% MAX. ±2% ±2%<br />

ASTM D 0573 ASTM D 0573 ASTM D 3045 ASTM D 573 ASTM D 573<br />

90% STRENGTH RETENTION OF ORIGINAL 90% STRENGTH RETENTION OF 90% STRENGTH RETENTION OF TENSILE STRENGTH 225 LB/F TENSILE STRENGTH 225 LB/F<br />

ORIGINAL<br />

ORIGINAL<br />

ASTM D 1149 ASTM D 1149 3 DAYS @ 100 PPHM -- 100 F AND ASTM D 1149 ASTM D 1149<br />

3 DAYS @ 300 PPHM -- 100 F<br />

PASS, NO CRACKS PASS, NO CRACKS NO CRACKING PASS PASS<br />

7 X MAGNIFICATION 7X MAGNIFICATION<br />

ASTM D 2565 ASTM D 2565 ASTM D 2565 ASTM G 26 ASTM G 26<br />

(XENON ARC) (XENON ARC) (XENON ARC)<br />

10 M HRS., NO CHANGE 10 M HRS., NO CHANGE 10 M HRS., NO CHANGE PASS PASS<br />

FS 1018, METHOD 2031 FS 1018, METHOD 2031 FS 1018, METHOD 2031 FTM 101C, METHOD 2031 FTM 101C, METHOD 2031<br />

295 LBS. 260 LBS. 260 LBS. 200 LBS. MINIMUM 200 LBS. MINIMUM<br />

ASTM D 751 ASTM D 751 ASTM D 751<br />

110 X 100 LBS. 100 X 100 LBS. 120 X 120 LBS.<br />

ASTM D 751 ASTM D 751 ASTM D 751 ASTM D 751 ASTM D 751<br />

PROCEDURE B<br />

PROCEDURE B<br />

120 X 110 LBS. 100 X 100 LBS. 120 X 120 LBS. 55 LB./F 55 LB./F<br />

ASTM D 2136 ASTM D 2136 ASTM D 2136 ASTM D 2137 ASTM D 2137<br />

–40 F, NO CRACKS –40 F, NO CRACKS –40 F, NO CRACKS –40 F –40 F<br />

ASTM E 96 ASTM E 96 ASTM E 96 ASTM E 96 ASTM E 96<br />

WATER VAPOR TRANSMISSION WATER VAPOR TRANSMISSION WATER VAPOR TRANSMISSION<br />

3.5/M 2 /DAY 3.5/M 2 /DAY 3.5/M 2 /DAY .012 PERMS .012 PERMS<br />

ASTM D 1204 ASTM D 1204 ASTM D 1204 ASTM D 1204 ASTM D 1204<br />

< 0.5% < 0.5% < 0.5% ±2% ±2%<br />

37-GP-54<br />

PASS<br />

345


Other Prefabricated Sheet-Applied Membranes Part 2: Test Results<br />

1. COMPANY NAME HYLOAD INC. HYLOAD, INC. HYLOAD, INC. HYLOAD, INC.<br />

2. PRODUCT NAME 150 E 250 E HYLOAD WS HYLOAD SAM<br />

3. PRODUCT DESCRIPTION COAL TAR / ELVALOY COAL TAR / ELVALOY COAL TAR / ELVALOY COAL TAR / ELVALOY<br />

KEE / POLYESTER MEMBRANE KEE / POLYESTER MEMBRANE KEE / POLYESTER MEMBRANE KEE / POLYESTER MEMBRANE<br />

4. THICKNESS METHOD ASTM D 2083 ASTM D 2083 ASTM D 2083 ASTM D 2083<br />

RESULTS 60 MIL 60 MIL 75 MIL 75 MIL<br />

5. TENSILE STRENGTH METHOD ASTM D 412 ASTM D 412 ASTM D 412 ASTM D 412<br />

RESULTS 1600 LBS/SQ IN 1600 LBS/SQ IN 1500 LBS/SQ. IN. 1500 LBS/SQ. IN.<br />

6. LAP JOINT METHOD METHOD HEAT WELD HEAT WELD HEAT WELD SELF-ADHERED<br />

RESULTS<br />

7. ELONGATION AT BREAK METHOD ASTM D 412 ASTM D 412 ASTM D 412 ASTM D 412<br />

RESULTS 170% 170% 170% 170%<br />

8. TENSILE SET METHOD<br />

RESULTS<br />

9. LOW TEMPERATURE METHOD CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M<br />

FLEXIBILITY<br />

RESULTS PASS PASS PASS PASS<br />

10. WATER ABSORPTION METHOD<br />

RESULTS<br />

11. DIMENSIONAL STABILITY METHOD<br />

AFTER WATER<br />

ABSORPTION<br />

RESULTS<br />

12. HEATING AGING METHOD<br />

RESULTS<br />

13. OZONE RESISTANCE METHOD<br />

RESULTS<br />

14. RESISTANCE TO METHOD CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M<br />

ACCELERATED<br />

WEATHERING RESULTS PASS PASS PASS PASS<br />

15. DYNAMIC IMPACTING METHOD ASTM D 624 ASTM D 624 ASTM D 624 ASTM D 624<br />

(PUNCTURING)<br />

RESULTS 300 LBS. 300 LBS. 165 LBS. 270 LBS.<br />

16 TEAR RESISTANCE METHOD<br />

RESULTS<br />

17. TEARING STRENGTH METHOD<br />

RESULTS<br />

18. LOW TEMPERATURE METHOD<br />

IMPACT<br />

RESULTS<br />

19. PERMEABILITY METHOD ASTM E 96 PROC A ASTM E 96 PROC A ASTM E 96 PROC A ASTM E 96 PROC A<br />

RESULTS 0.136/GRAINS/IN. HG. SQ. FT. 0.136/GRAINS/IN. HG. SQ. FT. 0.136/GRAINS/IN. HG. SQ. FT. 0.136/GRAINS/IN. HG. SQ. FT.<br />

20. DIMENSIONAL CHANGE METHOD<br />

AFTER STRESS<br />

RELAXATION<br />

RESULTS<br />

21. CONE PENETRATION METHOD<br />

22. SEE APPENDIX IF<br />

CHECKED<br />

RESULTS<br />

346


Other Prefabricated Sheet-Applied Membranes Part 2: Test Results<br />

HYLOAD, INC. HYLOAD, INC. HYLOAD, INC. HYLOAD, INC. HYLOAD, INC.<br />

HYBASE SAM HYBASE SAM UR HYBASE SAM URWS HYLOAD PMUB ALPSAM<br />

COAL TAR / ELVALOY COAL TAR / ELVALOY COAL TAR / ELVALOY COAL TAR / ELVALOY POLYESTER REINFORCED<br />

KEE / POLYESTER MEMBRANE KEE / POLYESTER MEMBRANE KEE / POLYESTER MEMBRANE KEE / POLYESTER MEMBRANE ELVALOY KEE MEMBRANE<br />

ASTM D 2083 ASTM D 2083 ASTM D 2083 ASTM D 2083 ASTM D 2083<br />

50 MIL 50 MIL 50 MIL 70 MIL 75 MIL<br />

ASTM D 412 ASTM D 412 ASTM D 412 ASTM D 412 ASTM D 412<br />

1400 LBS/SQ. IN. 1400 LBS/SQ. IN. 1400 LBS/SQ. IN. 1500 LBS/SQ. IN. 1300 LBS/SQ. IN.<br />

SELF-ADHERED SELF-ADHERED HEAT WELD SELF-ADHERED SELF-ADHERED<br />

ASTM D 412 ASTM D 412 ASTM D 412 ASTM D 412 ASTM D 412<br />

170% 170% 170% 170% 170%<br />

CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M<br />

PASS PASS PASS PASS PASS<br />

CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M<br />

PASS PASS PASS PASS PASS<br />

ASTM D 624 ASTM D 624 ASTM D 624 ASTM D 624 ASTM D 624<br />

150 LBS. 150 LBS. 150 LBS. 150 LBS. 150 LBS.<br />

ASTM E 96 PROC A ASTM E 96 PROC A ASTM E 96 PROC A ASTM E 96 PROC A ASTM E 96 PROC A<br />

0.136/GRAINS/IN. HG. SQ. FT. 0.136/GRAINS/IN. HG. SQ. FT. 0.136/GRAINS/IN. HG. SQ. FT. 0.136/GRAINS/IN. HG. SQ. FT. 0.136/GRAINS/IN. HG. SQ. FT.<br />

347


Other Prefabricated Sheet-Applied Membranes Part 2: Test Results<br />

1. COMPANY NAME HYLOAD, INC. INTERCONTINENTAL COATINGS INTERCONTINENTAL COATINGS INTERCONTINENTAL COATINGS<br />

2. PRODUCT NAME ALPSAM WS ROOFTEC HA ROOFTEC CA SA ROOFTEC WS<br />

3. PRODUCT DESCRIPTION POLYESTER REINFORCED COAL TAR / ELVALOY COAL TAR / ELVALOY COAL TAR / ELVALOY<br />

ELVALOY KEE MEMBRANE KEE/POLYESTER MEMBRANE KEE/POLYESTER MEMBRANE KEE/POLYESTER MEMBRANE<br />

4. THICKNESS METHOD ASTM D 2083 ASTM D 2083 ASTM D 2083 ASTM D 2083<br />

RESULTS 75 MIL 60 MIL 60 MIL 75 MIL<br />

5. TENSILE STRENGTH METHOD ASTM D 412 ASTM D 412 ASTM D 412 ASTM D 412<br />

RESULTS 1500 LBS./SQ. IN. 1600 LB/SQ.IN 1600 LB/SQ.IN 1500 LB/SQ.IN<br />

6. LAP JOINT METHOD METHOD HEAT WELD HEAT WELD HEAT WELD HEAT WELD<br />

RESULTS<br />

7. ELONGATION AT BREAK METHOD ASTM D 412 ASTM D 412 ASTM D 412 ASTM D 412<br />

RESULTS 170% 170% 170% 170%<br />

8. TENSILE SET METHOD<br />

RESULTS<br />

9. LOW TEMPERATURE METHOD CGSB 37-GP56M CGSB 37-GP56M CGSB 37GP56M CGSB 37-GP56M<br />

FLEXIBILITY<br />

RESULTS PASS PASS PASS PASS<br />

10. WATER ABSORPTION METHOD<br />

RESULTS<br />

11. DIMENSIONAL STABILITY METHOD<br />

AFTER WATER<br />

ABSORPTION<br />

RESULTS<br />

12. HEATING AGING METHOD<br />

RESULTS<br />

13. OZONE RESISTANCE METHOD<br />

RESULTS<br />

14. RESISTANCE TO METHOD CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M<br />

ACCELERATED<br />

WEATHERING RESULTS PASS PASS PASS PASS<br />

15. DYNAMIC IMPACTING METHOD ASTM D 624 CGSB37 - CGSB37 - CGSB37 -<br />

(PUNCTURING) GP56M GP56M GP56M<br />

RESULTS 150 LBS. PASS PASS PASS<br />

16 TEAR RESISTANCE METHOD ASTM D 624 ASTM D 624 ASTM D 624<br />

RESULTS 330 LBS. 330 LBS. 165 LBS.<br />

17. TEARING STRENGTH METHOD<br />

RESULTS<br />

18. LOW TEMPERATURE METHOD<br />

IMPACT<br />

RESULTS<br />

19. PERMEABILITY METHOD ASTM E 96 PROC A ASTM E 96 PROCEDURE A ASTM E 96 PROCEDURE A ASTM E 96 PROCEDURE A<br />

WATER VAPOR TRANSMISSION WATER VAPOR TRANSMISSION WATER VAPOR TRANSMISSION<br />

RESULTS 0.136/GRAINS/IN. HG. SQ. FT. 0.136/GRAINS/IN. HG. SQ. FT. 0.136/GRAINS/IN. HG. SQ. FT. 0.136/GRAINS/IN. HG. SQ. FT.<br />

20. DIMENSIONAL CHANGE METHOD<br />

AFTER STRESS<br />

RELAXATION<br />

RESULTS<br />

21. CONE PENETRATION METHOD<br />

22. SEE APPENDIX IF<br />

CHECKED<br />

RESULTS<br />

348


Other Prefabricated Sheet-Applied Membranes Part 2: Test Results<br />

INTERCONTINENTAL COATINGS INTERCONTINENTAL COATINGS INTERCONTINENTAL COATINGS INTERCONTINENTAL COATINGS INTERCONTINENTAL COATINGS<br />

ROOFTEC SA ROOFTEC SAB ROOFTEC SABU ROOFTEC SABU WS ROOFTEC SAPM<br />

COAL TAR / ELVALOY COAL TAR / ELVALOY COAL TAR / ELVALOY COAL TAR / ELVALOY COAL TAR / ELVALOY<br />

KEE/POLYESTER MEMBRANE KEE/POLYESTER MEMBRANE KEE/POLYESTER MEMBRANE KEE/POLYESTER MEMBRANE KEE/POLYESTER MEMBRANE<br />

ASTM D 2083 ASTM D 2083 ASTM D 2083 ASTM D 2083 ASTM D 2083<br />

75 MIL 50 MIL 50 MIL 50 MIL 70 MIL<br />

ASTM D 412 ASTM D 412 ASTM D 412 ASTM D 412 ASTM D 412<br />

1500 LB/SQ.IN 1400 LB/SQ. IN. 1400 LB/SQ. IN. 1400 LBS/SQ. IN. 1500 LBS/SQ. IN.<br />

SELF-ADHERED SELF-ADHERED SELF-ADHERED HEAT WELD SELF-ADHERED<br />

ASTM D 412 ASTM D 412 ASTM D 412 ASTM D 412 ASTM D 412<br />

170% 170% 170% 170% 170%<br />

CGSB 37GP56M CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M CGSB 37GP56M<br />

PASS PASS PASS PASS PASS<br />

CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M<br />

PASS PASS PASS PASS PASS<br />

CGSB37 - CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M CGSB 37-GP56M<br />

GP56M<br />

PASS PASS PASS PASS PASS<br />

ASTM D 624 ASTM D 624 ASTM D 624 ASTM D 624 ASTM D 624<br />

270 LBS. 150 LBS. 150 LBS. 150 LBS. 165 LBS.<br />

ASTM E 96 PROCEDURE A ASTM E 96, PROCEDURE A ASTM E 96, PROCEDURE A ASTM E 96 PROCEDURE A ASTM E 96 PROCEDURE A<br />

WATER VAPOR TRANSMISSION WATER VAPOR TRANSMISSION WATER VAPOR TRANSMISSION WATER VAPOR TRANSMISSION WATER VAPOR TRANSMISSION<br />

0.136/GRAINS/IN. HG. SQ. FT. 0.136 GRAIN/IN HG SQ FT 0.136 GRAIN/IN HG SQ FT 0.136/GRAINS/IN. HG. SQ. FT. 0.136/GRAINS/IN. HG. SQ. FT.<br />

349


Other Prefabricated Sheet-Applied Membranes Part 2: Test Results<br />

1. COMPANY NAME INTERCONTINENTAL COATINGS INTERCONTINENTAL COATINGS SEAMAN CORP. SEAMAN CORP.<br />

2. PRODUCT NAME ROOFTEC SAW ROOFTEC SAW WS FIBERTITE FB FIBERTITE<br />

3. PRODUCT DESCRIPTION POLYESTER REINFORCED POLYESTER REINFORCED POLYESTER REINFORCED POLYESTER REINFORCED<br />

ELVALOY KEE MEMBRANE ELVALOY KEE MEMBRANE EIP/KEE W/FLEECE BACKING EIP/KEE<br />

4. THICKNESS METHOD ASTM D 2083 ASTM D 2083 ASTM D 751 ASTM D 751<br />

RESULTS 75 MIL 75 MIL 40 MIL 33 MILS NOM<br />

5. TENSILE STRENGTH METHOD ASTM D 412 ASTM D 412 ASTM D 751 ASTM D 751, GRAB METHOD<br />

ASTM D 882 ASTM D 882<br />

RESULTS 1300 LBS/SQ. IN. 1500 LBS./SQ. IN. 375 X 300 LBS. 450 LBS. X 450 LBS.<br />

8500 PSI 8500 PSI<br />

6. LAP JOINT METHOD METHOD SELF-ADHERED HEAT WELD ASTM D 751 ASTM D 751<br />

RESULTS > 400 LBS. >400 LBS.<br />

7. ELONGATION AT BREAK METHOD ASTM D 412 ASTM D412 ASTM D 751 ASTM D 751<br />

RESULTS 170% 170% 15% WARP X 15% FILL 20% WARP, 30% FILL<br />

8. TENSILE SET METHOD<br />

RESULTS<br />

9. LOW TEMPERATURE METHOD CGSB 37-GP56M CGSB 37-GP56M ASTM D 2146 ASTM D 2136<br />

FLEXIBILITY<br />

RESULTS PASS PASS –30 F, NO CRACKS –30 F, NO CRACKS<br />

10. WATER ABSORPTION METHOD ASTM D 471 ASTM D 471<br />

14 DAYS @ 70 C 14 DAYS @ 70 C<br />

RESULTS 1% 1%<br />

11. DIMENSIONAL STABILITY METHOD<br />

AFTER WATER<br />

ABSORPTION<br />

RESULTS<br />

12. HEATING AGING METHOD ASTM D 3045 (160 F/7 DAYS) ASTM D 3045<br />

7 DAYS @ 160 F<br />

RESULTS >90% STRENGTH RETENTION >90% STRENGTH RETENTION<br />

13. OZONE RESISTANCE METHOD 3 DAYS @ 100PPHM -- 100F AND 3 DAYS @ 100PPHM -- 100F AND<br />

3 DAYS @ 300 PPHM -- 100 F 3 DAYS @ 300 PPHM -- 100 F<br />

RESULTS NO CRACKING NO CRACKING<br />

14. RESISTANCE TO METHOD CGSB 37-GP56M CGSB 37-GP56M ASTM D 2565 ASTM D 2565<br />

ACCELERATED ASTM E 838<br />

WEATHERING RESULTS PASS PASS 5,000 HOURS, NO CRACKING 5,000 HOURS, NO CRACKING<br />

3 MILLION LANGLEYS<br />

15. DYNAMIC IMPACTING METHOD CGSB 37-GP56M CGSB 37-GP56M ASTM D 5635 ASTM D 5635<br />

(PUNCTURING)<br />

RESULTS PASS PASS 20 JOULES 15 JOULES<br />

16 TEAR RESISTANCE METHOD ASTM D 624 ASTM D 624 ASTM D 751 ASTM D 751<br />

8 IN. X 10 IN. SAMPLE 8 IN. X 10 IN. SAMPLE<br />

RESULTS 165 LBS. 165 LBS. 50 X 50 LBS. 120 X 120<br />

17. TEARING STRENGTH METHOD ASTM D 751 ASTM D 751<br />

8 IN. X 10 IN. SAMPLE 8 IN. X 10 IN. SAMPLE<br />

RESULTS 50 X 50 LBS. 120 X 120<br />

18. LOW TEMPERATURE METHOD ASTM D 2136, –30 F ASTM D 2136,–30 F<br />

IMPACT<br />

RESULTS NO CRACKING NO CRACKING<br />

19. PERMEABILITY METHOD ASTM E 96 PROCEDURE A ASTM E 96 PROCEDURE A ASTM E 96 PROCEDURE A ASTM E 96, PROCEDURE A<br />

WATER VAPOR TRANSMISSION WATER VAPOR TRANSMISSION WATER VAPOR TRANSMISSION WATER VAPOR TRANSMISSION<br />

RESULTS 0.136/GRAINS/IN. HG. SQ. FT. 0.136/GRAINS/IN. HG. SQ. FT. 1.3 G/MXM/24H 1.3 G/MXM/24H<br />

20. DIMENSIONAL CHANGE METHOD ASTM D 1204 37-GP-54M<br />

AFTER STRESS<br />

RELAXATION RESULTS


Other Prefabricated Sheet-Applied Membranes Part 2: Test Results<br />

VERSICO INCORPORATED<br />

VERSIWELD PREMIER<br />

TPO THERMOPLASTIC OLEFIN<br />

VERSICO INCORPORATED<br />

VERSIWELD PREMIER EF<br />

TPO THERMOPLASTIC OLEFIN<br />

ASTM D 751 ASTM D 751<br />

0.045, 0.060 0.045, 0.060<br />

0.015 IN. MIN 0.015 IN. MIN<br />

ASTM 751 BREAKING STRENGTH<br />

ASTM 751 BREAKING STRENGTH<br />

340 LBF 340 LBF<br />

HEAT WELD<br />

HEAT WELD<br />

RUPTURE OUTSIDE SEAM RUPTURE OUTSIDE SEAM<br />

OVERLAP<br />

OVERLAP<br />

ASTM D 751 ASTM D 751<br />

25% 25%<br />

FABRIC RUPTURE<br />

FABRIC RUPTURE<br />

ASTM D 2137 ASTM D 2137<br />

-50 F (7 DAYS @ 158F) -50 F (7 DAYS @ 158F)<br />

ASTM D 471 ASTM D 471<br />

+2.0% +2.0%<br />

ASTM D 573 ASTM D 573<br />

28 DAYS @ 240 F 28 DAYS @ 240 F<br />

BREAKING STRENGTH 340 LBF BREAKING STRENGTH 340 LBF<br />

TEAR STRENGTH 130 LBF TEAR STRENGTH 130 LBF<br />

ASTM D 1149 ASTM D 1149<br />

168 HOURS @ 100 PPHM 168 HOURS @ 100 PPHM<br />

NO CRACKS<br />

NO CRACKS<br />

ASTM G26<br />

ASTM G26<br />

5040 KJ/M², 176 F 5040 KJ/M², 176 F<br />

NO LOSS BREAKING/TEARING NO LOSS BREAKING/TEARING<br />

STRENGTH, NO SURFACE CRACKS STRENGTH, NO SURFACE CRACKS<br />

ASTM D 751 ASTM D 751<br />

TONGUE TEAR<br />

TONGUE TEAR<br />

130 LBF 130 LBF<br />

0.05 PERMS TYPICAL 0.05 PERMS TYPICAL<br />

0.10 PERMS MAX 0.10 PERMS MAX<br />

ASTM E 96 B OR BW<br />

ASTM E 96 B OR BW<br />

0.05 PERMS 0.05 PERMS<br />

351


Spray Polyurethane Foam-based Systems; Part 1: Insulation<br />

1. COMPANY NAME FOAM FOAM FOAM FOAM FOAM<br />

ENTERPRISES ENTERPRISES ENTERPRISES ENTERPRISES ENTERPRISES<br />

INC. INC. INC. INC. INC.<br />

2. PRODUCT NAME FE 303-2.0 FE 303 FE 303 FE 314-3.0 FE 700<br />

SERIES SEREIS SERIES SERIES<br />

3. COMPLIES WITH:<br />

ASTM C 1029-96, Standard Specification for Spray-Applied Rigid<br />

Cellular Polyurethane Thermal Insulation (Type I, II, III or IV)<br />

2.7 3.0 3.0 ADHESIVE<br />

TYPE I TYPE III TYPE III TYPE III TYPE I<br />

4. PHYSICAL PROPERTIES<br />

Nominal Density Per ASTM D 1622 or Other (lbs/ft 3 ) 2.0 2.7 - 2.9 2.8-3.05 3.0 - 3.4 2.0<br />

Compressive Strength Per ASTM D 1621 or Other (psi) 26 45 - 60 45 - 60 40 - 55 12<br />

Closed-Cell Content Per ASTM D 2856 or Other (% min) 88 - 95 88 - 95 88 - 95 87 -96 55<br />

Thermal Resistance R-Value at: 1 inch 7.0 6.7 6.7 6.25 3.4<br />

Thermal Resistance R-Value at: 2 inches 14.0 13.4 13.4 13.4 6.8<br />

Thermal Resistance R-Value at: 3 inches 21.0 20.1 20.1 20.1 10.0<br />

5. APPLICATION CONDITIONS<br />

Ambient Air Temperature Ranges (degrees F) 45 - 110 45 - 110 45 - 110 45 - 110 45 - 110<br />

Maximum Ambient Relative Humidity (%)<br />

W/N 5% DEWPOINT W/N 5% DEWPOINT W/N 5% DEWPOINT W/N 5% DEWPOINT W/N 5% DEWPOINT<br />

Maximum Allowable Wind Velocity Without Wind Screen (mph) 15 15 15 15 15<br />

Maximum Allowable Wind Velocity With Wind Screen (mph) 25 28 25 25 25<br />

6. RECOMMENDED TYPE OF PROTECTIVE COATINGS (see SPF-<br />

Based <strong>Roof</strong> Systems, Part 2 -- Protective Coatings)<br />

7.<br />

Acrylic X X X<br />

Butyl X X X<br />

Hypalon X X X<br />

Neoprene X X X<br />

Silicones X X X<br />

Urethanes X X X<br />

Vinyls X X X<br />

Modified Asphalts X X X<br />

Aggregate X X X<br />

PROTECTIVE COATING AVAILABLE FROM MANUFACTURER<br />

(yes/no)<br />

8. FIRE RESISTANCE CLASSIFICATION:<br />

UL Classification per ANSI/UL 790 as part of any roof system<br />

(indicate Class A, B or C, or none)<br />

YES YES YES YES YES<br />

NONE A A A NONE<br />

FM Class 1 as part of any roof system (yes/no) NO YES YES YES NO<br />

9. YEAR OF FIRST COMMERCIAL USE 1984 1984 1986 1986 1998<br />

10. NUMBER OF SQUARES INSTALLED (100 ft 2 ) >1,000,000 >50,000 >500 >500<br />

11.<br />

MANUFACTURER-QUALIFIED APPLICATORS REQUIRED<br />

(yes/no)<br />

NO YES YES YES NO<br />

12. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DSTRB/DIRECT DSTRB/DIRECT DSTRB/DIRECT DSTRB/DIRECT DSTRB/DIRECT<br />

13. NUMBER OF REGIONAL SERVICE LOCATIONS 6 6 6 6 6<br />

14. SALES INFORMATION, CONTACT: J. ANDERSEN J. ANDERSEN J. ANDERSEN J. ANDERSEN J. ANDERSEN<br />

TECHNICAL INFORMATION, CONTACT:<br />

888/900-3626 888/900-3626 888/900-3626 888/900-3626 888/900-3626<br />

J. ANDERSEN J. ANDERSEN J. ANDERSEN J. ANDERSEN J. ANDERSEN<br />

888/900-3626 888/900-3626 888/900-3626 888/900-3626 888/900-3626<br />

15. SEE MEMBRANE APPENDIX IF CHECKED X X X X X<br />

352


Spray Polyurethane Foam-based Systems; Part 1: Insulation<br />

GACO GACO GACO NORTH NORTH NORTH NORTH SWD SWD SWD<br />

WESTERN WESTERN WESTERN CAROLINA CAROLINA CAROLINA CAROLINA URETHANE URETHANE URETHANE<br />

INC. INC. INC. FOAM IND. FOAM IND. FOAM IND. FOAM IND. CO. CO. CO.<br />

POLYFOAM POLYFOAM POLYFOAM NCI SYSTEM NCI SYSTEM NCI SYSTEM NCI SYSTEM SWD<br />

251 303 275 591 - 2.5 591 - 2.8 692 - 2.5 692 - 2.8 525b-2.5 525b-2.5 525b-3.0<br />

TYPE I TYPE II TYPE I<br />

2.4 - 2.8 2.8 - 3.2 2.5 - 2.9 2.7 3.0 2.0 2.5 3.0<br />

44 52 41 35 45 25 40 50<br />

95 95 90 90 90 90 90 95 95 95<br />

7.7 7.7 7.3 6.7 6.7 6.7 6.7 7 7 7<br />

15.4 15.4 14.6 13.0 13.0 13.0 13.0 14 14 14<br />

23.1 23.1 21.9 20.0 20.0 20.0 20.0 21 21 21<br />

55 - 100 55 - 100 55 - 100 50 min. 50 min. 50 min. 50 min. 50+ 50+ 50+<br />

80 80 80 78 78 78 78 80 80 80<br />

15 15 15 15 15 15 15 15 15 15<br />

20 20 20 25 25 25 25 20 20 20<br />

X X X X x X X X<br />

X X X X x<br />

X X X X x<br />

X X X X x<br />

X X X X x X X X<br />

X X X X x<br />

X<br />

x<br />

X<br />

x<br />

X x X X<br />

YES YES YES NO NO NO NO YES YES YES<br />

A A A A A A A A A A<br />

NO NO NO NO YES NO NO NO YES YES<br />

1984 1984 1984 1991 1991 1992 1992 1972 1972 1972<br />

>500,000 >600,000 >350,000 1,000,000 300,000 3,500 1,000 THOUSANDS 100,000 100,000<br />

NO NO NO NO NO YES YES NO YES YES<br />

DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DSTRB/DIRECT DSTRB/DIRECT DSTRB/DIRECT<br />

3 3 3 1 1 1 1 2 2 2<br />

J. FREMESSER J. FREMESSER J. FREMESSER S. RIDDLE S. RIDDLE S. RIDDLE S. RIDDLE R. WHIPPLE R. WHIPPLE R. WHIPPLE<br />

800/869-0960 800/869-0960 800/869-0960 336/789-9161 336/789-9161 336/789-9161 336/789-9161 800/828-1394 800/828-1394 800/828-1394<br />

A. JENKINS A. JENKINS A. JENKINS C. TOLBERT C. TOLBERT C. TOLBERT C. TOLBERT R. WHIPPLE R. WHIPPLE R. WHIPPLE<br />

800/456-4228 800/456-4228 800/456-4228 336/789-9161 336/789-9161 336/789-9161 336/789-9161 800/828-1394 800/828-1394 800/828-1394<br />

X X X X X X X<br />

353


Spray Polyurethane Foam-Based Systems; Part 2: Protective Coatings<br />

1. COMPANY NAME ANDEK ANDEK ANDEK ANDEK ANDEK<br />

CORP. CORP. CORP. CORP. CORP.<br />

2. PRODUCT NAME POLAROOF POLAROOF POLAROOF NW POLAROOF AC POLAROOF<br />

R.A.C. R.A.C. 02 FIREGARD<br />

3A. COATING DESCRIPTION<br />

Acrylilc<br />

X<br />

Butyl<br />

Hypalon<br />

Neoprene<br />

Silicone<br />

Urethane X X<br />

Vinyl<br />

Modified Asphalt<br />

Other (type) ETHYLENE ELASTOMER PVC<br />

3B. VAPOR RETARDER (yes, perm rating 1.0) NO NO YES NO NO<br />

3C. COLORS AVAILABLE SILVER SILVER ANY COLOR ANY COLOR ANY COLOR<br />

4. BASE COATING (Name of Product) POLAROOF POLAROOF POLAROOF NW POLAROOF AC POLARROOF<br />

R.A.C. R.A.C. 02 FIREGARD<br />

TOP COATING (Name of Product) POLAROOF POLAROOF POLAROOF NW POLAROOF AC POLAROOOF<br />

R.A.C. R.A.C. 02 FIREGARD<br />

5. NUMBER OF COATING APPLICATIONS REQUIRED<br />

Base Coatings 1 1 1 1 1<br />

Top Coatings 1 1 1 1 1<br />

Granules Required (yes, no or optional) NO NO NO NO NO<br />

6. REQUIRED DRY FILM THICKNESS: (mils)<br />

Base Coating 15 15 12 15 10<br />

Tom Coating 15 15 12 15 10<br />

7. FILM CURE TIME<br />

Base Coating 8 HOURS 8 HOURS 14 2 1 HOUR<br />

Top Coating 8 HOURS 8 HOURS 16 1 1 HOUR<br />

8. MINIMUM SLOPE REQUIRED (inches per foot) NONE NONE NONE 2 1/4"<br />

9. REQUIREMENTS FOR USE OVER:<br />

(X=direct application permitted) (P=primer required)<br />

(T=thermal barrier required)<br />

Concrete Decks X X P P P<br />

Plywood Decks P P P P P<br />

Metal Decks X X X X X<br />

Existing Spudded Built-up <strong>Roof</strong>ing X X X X X<br />

Other Coatings X X X X X<br />

10. FLASHING MATERIAL (type or self-flashing) SELF SELF SELF SELF SELF<br />

11. APPLICATION CONDITIONS<br />

Recommended Ambient Air Temperature Range (degrees F) 30 – 100 20 – 100 0 – 90 45 – 90 45<br />

Maximum Permitted Wind Velocity Without Screen (mph) 10 10 10 10 10<br />

Maximum Permitted Wind Velocity With Wind Screen (mph) 15 15 15 15 15<br />

12. APPLICATION EQUIPMENT REQUIREMENTS<br />

Single-Component Airless Spray X X X X X<br />

Multi-Component Airless Spray<br />

Other (roller, brush, etc.) ROLLER, BRUSH ROLLER, BRUSH ROLLER, BRUSH ROLLER, BRUSH ROLLER, BRUSH<br />

13. RESTRICTED REGIONS (yes/none) NONE NONE NONE NONE NONE<br />

14. RESTRICTED BUILDING USES (yes/none) NONE NONE YES YES NONE<br />

15. RECOMMENDED RECOATING SCHEDULE (years or none) 10 10 10 10 10<br />

16. PHYSICAL PROPERTIES OF THE COATING<br />

Tensile Strength Per ASTM D 412 or Other (psi) 620 1400 864 250 520<br />

Elongation Per ASTM D 412 or Other (%) 570 570 550 500 1000<br />

Impact Resistance Per ASTM D 2794 or Other (inch lbs) 210 630 280 120 140<br />

Accelerated Weathering Per ASTM D 882 or Other (color change) NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE<br />

Heat Aging Per ASTM D 573 or Other (%) NONE NONE NONE NONE NONE<br />

Water Absorption Per ASMT D 570 or Other (%) NONE NONE NONE 1.3% 2.5%<br />

17. UL 790 FLAMMABILITY CLASS A RATING IN ANY SYSTEM (yes/no) YES YES NO YES YES<br />

18. FOAM INSULATION REQUIREMENTS<br />

Minimum Thickness (inches) 1 1 2 1 1<br />

Nominal Density Per ASTM D 1622 or Other (lbs/ft 3 ) 2.5 – 3.5 2.5 – 3.5 2.5 – 3.5 2.5 – 3.5 2.5 - 3.5<br />

Compressive Strength Per ASTM D 1621 or Other (psi) 40 MIN. 40 MIN. 40 MIN. 40 MIN. 40 MIN.<br />

Closed Cell Content Per ASTM D 2856 or Other (%) 90 MIN. 90 MIN. 90 MIN. 90 MIN. 40 MIN.<br />

19. FOAM AVAILABLE FROM MANUFACTURER (yes/no) NO NO NO NO NO<br />

20. YEAR OF FIRST COMMERCIAL USE 1978 1988 1985 1996 1975<br />

21. NUMBER OF SQUARES INSTALLED (100 ft 2 ) 420,000 80,000 85000 150,000 15,000<br />

22. MANUFACTURER-QUALIFIED APPLICATOR REQUIRED (yes/no) YES YES YES YES YES<br />

23. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRIBUTORS<br />

24. NUMBER OF REGIONAL SERVICE LOCATIONS 5 5 5 5 5<br />

25. SALES INFORMATION, CONTACT: HARVEY LISS HARVEY LISS HARVEY LISS HARVEY LISS HARVEY LISS<br />

800/800-2844 800/800-2844 800/800-2844 800/800-2844 800/800-2844<br />

TECHNICAL INFORMATION, CONTACT: NEIL SHEARER NEIL SHEARER NEIL SHEARER NEIL SHEARER NEIL SHEARER<br />

26. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

888/882-6335 888/882-6235 888/882-6235 888/882-6235 888/882-6235<br />

354


Spray Polyurethane Foam-Based Systems; Part 2: Protective Coatings<br />

CONKLIN CONKLIN CONKLIN CONKLIN CONKLIN CONKLIN DOW ERSYSTEMS ERSYSTEMS<br />

CO., INC. CO., INC. CO., INC. CO., INC. CO., INC. CO., INC. CORNING<br />

CORP.<br />

RAPID ROOF II RAPID ROOF III POLYTUFF II POLYTUFF II BENCHMARK BENCHMARK DOW CORNING ERATHANE ERATHANE<br />

BASE COAT TOP COAT BASE COAT TOP COAT BASE COAT TOP COAT 3-5000 SILICONE 300 300<br />

ROOF COATING BASE<br />

X X X X<br />

X<br />

X<br />

X X X<br />

NO NO YES YES YES YES NO NO NO<br />

TAN WHITE, TAN, SILVER, GRAY WHITE BLUE WHITE, GRAY DK GRAY, GRAY, GRAY GRAY<br />

GRAY<br />

WHITE, BEIGE<br />

RAPID ROOF III POLYTUFF II BENCHMARK SAME ERATHANE 300<br />

BASE COAT BASE COAT BASE COAT BASE<br />

RAPID ROOF III POLYTUFF II BENCHMARK SAME ERATHANE 300<br />

TOP COAT TOP COAT TOP COAT BASE<br />

1 1 1 1 1<br />

1 1 1 1 1<br />

OPTIONAL NO NO OPTIONAL OPTIONAL OPTIONAL<br />

13 16.0 13.5 8 – 10 25<br />

12 4.0 13.5 7 – 10 10<br />

2 – 8 HOURS 2 – 4 HOURS 2 – 8 HOURS 2 – 6 HOURS 24 HRS @ 75F<br />

2 – 8 HOURS 30 MINS 2 – 8 HOURS 2 – 6 HOURS 12 HRS.<br />

1/4" 1/4" 1/4" 1/4" 1/4" 1/4" NO PONDING 1/8" 1/8"<br />

P P P P P P P X X<br />

P P P P P P X X X<br />

X X X X X X X X<br />

X X X X X X X X X<br />

X X X<br />

SELF SELF SELF SELF SELF SELF SELF SELF SELF<br />

50 – 100 50 – 100 40 – 100 40 – 100 50 – 100 50 – 100 >32 32+ 32+<br />

15 15 15 15 15 15 10 7 7<br />

25 25 25 25 25 25 25 25 25<br />

X X X X X X X X X<br />

ROLLER ROLLER ROLLER ROLLER ROLLER ROLLER<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

YES YES NONE NONE NONE NONE YES YES YES<br />

10+ 10+ 10+ 10+ 10+ 10+ NONE NONE NONE<br />

67 201 1400 1400 325 476 400 975 660<br />

377 262 630 630 375 118 150 825 200<br />

160 160 160 160 160 160<br />

NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE NONE NO CHANGE NO CHANGE<br />

NO CHANGE<br />

1,000,000 > 150,000 > 150,000 >1,000,000 >1,000,000 MILLIONS THOUSANDS THOUSANDS<br />

NO NO NO NO NO NO YES YES YES<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DIRECT DISTRS, DIRECT DISTRS, DIRECT<br />

5 5 5 5 5 5 7 14 14<br />

BUILD. PRODS. BUILD. PRODS. BUILD. PRODS. BUILD. PRODS. BUILD. PRODS. BUILD. PRODS. PROD INFORM. T. LEONARD T. LEONARD<br />

800/888-8838 800/888-8838 800/888-8838 800/888-8838 800/888-8838 800/888-8838 517/496–6000 800/403-7747 800/403-7747<br />

BUILD. PRODS. BUILD. PRODS. BUILD. PRODS. BUILD. PRODS. BUILD. PRODS. BUILD. PRODS. E. CARPINO T. LEONARD T. LEONARD<br />

800/888-8838 800/888-8838 800/888-8838 800/888-8838 800/888-8838 800/888-8838 517/496-4000 800/403-7747 800/403-7747<br />

X X X X X<br />

355


Spray Polyurethane Foam-Based Systems; Part 2: Protective Coatings<br />

1. COMPANY NAME ERSYSTEMS ERSYSTEMS ERSYSTEMS FOAM FOAM<br />

ENTERPRISES, ENTERPRISES,<br />

INC.<br />

INC.<br />

2. PRODUCT NAME ERAGUARD ERAGUARD ERAKOTE FE COAT FE COAT<br />

4000 1000 1000 SERIES 2000 SERIES<br />

3A. COATING DESCRIPTION<br />

Acrylilc X X<br />

Butyl<br />

Hypalon<br />

Neoprene<br />

Silicone<br />

X<br />

Urethane X X<br />

Vinyl<br />

Modified Asphalt<br />

Other (type)<br />

3B. VAPOR RETARDER (yes, perm rating 1.0) NO NO NO YES<br />

3C. COLORS AVAILABLE GRAY, WHITE GRAY, WHITE, WHITE GRAY, WHITE,<br />

CUSTOM DARK GRAY<br />

4. BASE COATING (Name of Product) ERAGUARD ERAGUARD ERAKOTE FE COAT FE COAT<br />

4000 1000 300 BASE 1000 2001<br />

TOP COATING (Name of Product) ERAGUARD ERAGUARD ERAKOTE FE COAT FE COAT<br />

4000 1000 1000 2002<br />

5. NUMBER OF COATING APPLICATIONS REQUIRED<br />

Base Coatings 1 1 1 1 1<br />

Top Coatings 1 1 1 1 1<br />

Granules Required (yes, no or optional) OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL<br />

6. REQUIRED DRY FILM THICKNESS: (mils)<br />

Base Coating 11 16 MIN. 25 20<br />

Tom Coating 11 16 MIN. 10 10<br />

7. FILM CURE TIME<br />

Base Coating 4 HRS @ 70F 10 HRS @ 70F 4.5 HRS @ 70F 4 - 6 HRS @ 70F<br />

Top Coating 4 HRS @ 70F 10 HRS @ 70F 10 HRS. @ 70F 4.5 HRS @ 70F 4 - 6 HRS @ 70F<br />

8. MINIMUM SLOPE REQUIRED (inches per foot) 1/8" 1/8" 1/8" 1/4" 1/4"<br />

9. REQUIREMENTS FOR USE OVER:<br />

(X=direct application permitted) (P=primer required)<br />

(T=thermal barrier required)<br />

Concrete Decks X X X P P<br />

Plywood Decks X X X P P<br />

Metal Decks X X X X X<br />

Existing Spudded Built-up <strong>Roof</strong>ing P X X X X<br />

Other Coatings X X P P<br />

10. FLASHING MATERIAL (type or self-flashing) SELF SELF SELF SELF SELF<br />

11. APPLICATION CONDITIONS<br />

Recommended Ambient Air Temperature Range (degrees F) 32+ 40+ 32+ >50 >35<br />

Maximum Permitted Wind Velocity Without Screen (mph) 7 7 7 15 15<br />

Maximum Permitted Wind Velocity With Wind Screen (mph) 25 25 25 25 25<br />

12. APPLICATION EQUIPMENT REQUIREMENTS<br />

Single-Component Airless Spray X X X X X<br />

Multi-Component Airless Spray<br />

Other (roller, brush, etc.) X X<br />

13. RESTRICTED REGIONS (yes/none) NONE NONE NONE NONE NONE<br />

14. RESTRICTED BUILDING USES (yes/none) YES YES YES COLD STORATE NONE<br />

15. RECOMMENDED RECOATING SCHEDULE (years or none) NONE NONE NONE 15 15<br />

16. PHYSICAL PROPERTIES OF THE COATING<br />

Tensile Strength Per ASTM D 412 or Other (psi) 450 250 1500 250 - 400 1000 - 2500<br />

Elongation Per ASTM D 412 or Other (%) 200 300 350 280 - 320 400 - 500<br />

Impact Resistance Per ASTM D 2794 or Other (inch lbs) SH SH<br />

Accelerated Weathering Per ASTM D 882 or Other (color change) NO CHANGE NO CHANGE NO CHANGE MIN. CHANGE MIN. CHANGE<br />

Heat Aging Per ASTM D 573 or Other (%)<br />

Water Absorption Per ASMT D 570 or Other (%)<br />

17. UL 790 FLAMMABILITY CLASS A RATING IN ANY SYSTEM (yes/no) YES YES YES YES<br />

18. FOAM INSULATION REQUIREMENTS<br />

Minimum Thickness (inches) 1 1 1 1 - 1.5 1 - 1.5<br />

Nominal Density Per ASTM D 1622 or Other (lbs/ft 3 ) 2.5 2.5 2.5 2.5 2.5<br />

Compressive Strength Per ASTM D 1621 or Other (psi) 40 40 MIN. 40 35 35<br />

Closed Cell Content Per ASTM D 2856 or Other (%) 90 90 90 >88 >88<br />

19. FOAM AVAILABLE FROM MANUFACTURER (yes/no) YES YES YES YES YES<br />

20. YEAR OF FIRST COMMERCIAL USE 1981 1993 1979 1995 1995<br />

21. NUMBER OF SQUARES INSTALLED (100 ft 2 ) THOUSANDS THOUSANDS THOUSANDS >500,000 >100,000<br />

22. MANUFACTURER-QUALIFIED APPLICATOR REQUIRED (yes/no) YES YES YES NO NO<br />

23. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT<br />

24. NUMBER OF REGIONAL SERVICE LOCATIONS 14 14 14 6 6<br />

25. SALES INFORMATION, CONTACT: T. LEONARD T. LEONARD T. LEONARD J. ANDERSEN J. ANDERSEN<br />

800/403-7747 800/403-7747 800/403-7747 888/900-FOAM 888/900-FOAM<br />

TECHNICAL INFORMATION, CONTACT: T. LEONARD T. LEONARD T. LEONARD J. ANDERSEN J. ANDERSEN<br />

26. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/403-7747 800/403-7747 800/403-7747 888/900-FOAM 888/900-FOAM<br />

356


Spray Polyurethane Foam-Based Systems; Part 2: Protective Coatings<br />

FOAM FOAM GACO GACO GACO GACO GACO GACO GACO<br />

ENTERPRISES, ENTERPRISES, WESTERN WESTERN WESTERN WESTERN WESTERN WESTERN WESTERN<br />

INC. INC. INC. INC. INC. INC. INC. INC. INC.<br />

FE COAT FE COAT GACOFLEX GACOFLEX GACOFLEX GACOSIL GACOFLEX GACOFLEX GACOFLEX<br />

3000 SERIES 4000 SERIES A-44 A-62 H-25 S-1000 U-6006 U-6006 U-68<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X<br />

NO NO YES<br />

WHITE WHITE WHITE GRAY ALUMINUM ALUMINUM OYSTER, PEWTER<br />

OYSTER WHITE ADOBE, SHALE, BLACK<br />

FE COAT FE COAT A-4411 A-6211 n/a GACOSIL S-1011 GACOFLEX U-68 GACOFLEX U-68 GACOFLEX U-68<br />

3000 4000<br />

FE COAT NA A-4400 A-6200 GACOFLEX H-25 GACOSIL S-1000 URE-SHIELD U-6006URE-SHIELD U-6006 GACOFLEX U-68<br />

3000<br />

1 1 2 2 0 1 2 2 2<br />

1 OTHER COAT 1 1 2 1 1 1 1<br />

OPTIONAL NA OPTIONAL OPTIONAL NO OPTIONAL NO NO OPTIONAL<br />

24 24 n/a 11 24 24 24<br />

12 12 6 11 12 12 12<br />

2-3 HRS @ 70 F 3-4 HRS @70F 24 HOURS 24 HOURS 24 HOURS 24 HOURS 24 HOURS 24 HOURS 24 HOURS<br />

2-3 HRS @ 70 F 3-4 HRS @70F 72 HOURS 72 HOURS 72 HOURS 72 HOURS 72 HOURS 72 HOURS 72 HOURS<br />

1/4" 1/4" ¼" ¼" ¼" ¼" ¼" ¼" ¼"<br />

P X P P p P p p P<br />

P X X X X X X X X<br />

X X P P P P P P<br />

X X X X X X X X X<br />

P P P P P P P P P<br />

SELF SELF SELF-FLASHING SELF-FLASHING SELF-FLASHING SELF-FLASHING SELF-FLASHING SELF-FLASHING SELF-FLASHING<br />

>35 >35 51-159 51-159 51-159 51-159 51-159 51-159 51-159<br />

15 15 >15 >15 >15 >15 >15 >15 >15<br />

25 25 >20 >20 >20 >20 >20 >20 >20<br />

X X X X X X X X X<br />

X X X<br />

X X X X X X X<br />

NONE NONE YES NONE NONE NONE NONE NONE NONE<br />

COLD STORAGE NONE NONE NONE NONE NONE NONE NONE NONE<br />

15 - 20 15 10 10 10 10 10 10 10<br />

300 300 175 + 20 275 + 10 700 480 1600 1600 2200<br />

125 75 250% 200% + 10 350% 210 400% 400% 350%<br />

MH -<br />

MIN CHANGE -<br />

-<br />

-<br />

YES YES YES YES YES YES YES<br />

1 - 1.5 1 - 1.5 1 1 1 1 1 1 1<br />

2.5 2.5


Spray Polyurethane Foam-Based Systems; Part 2: Protective Coatings<br />

1. COMPANY NAME GACO GACO GARDNER GARDNER GARDNER<br />

WESTERN WESTERN ASPHALT CORP/ ASPHALT CORP/ ASPHALT CORP/<br />

INC. INC. APOC DIVISION APOC DIVISION APOC DIVISION<br />

2. PRODUCT NAME GACOFLEX GACOFLEX APOC #252 GARDNER APOC #337<br />

U-66 UB-7050 SUN-WHITE ELASTOMERIC<br />

ELASTOMERIC ROOF COATING<br />

3A. COATING DESCRIPTION<br />

Acrylilc X X<br />

Butyl<br />

Hypalon<br />

Neoprene<br />

Silicone<br />

X<br />

Urethane X X<br />

Vinyl<br />

Modified Asphalt<br />

X<br />

Other (type)<br />

3B. VAPOR RETARDER (yes, perm rating 1.0) YES YES YES<br />

3C. COLORS AVAILABLE OYSTER, PEWTER, BASE COAT ONLY WHITE, TAN, WHITE BLACK<br />

SHALE<br />

RED, GRAY<br />

4. BASE COATING (Name of Product) GACOFLEX U-66 GACOFLEX UB-7050 APOC #252 GARDNER WHITE APOC #337<br />

ROOF COATING<br />

ROOF PATCH<br />

TOP COATING (Name of Product) GACOFLEX U-66 VARIES APOC #252 SAME APOC #252<br />

ROOF COATING<br />

5. NUMBER OF COATING APPLICATIONS REQUIRED<br />

Base Coatings 2 1 1 1 1<br />

Top Coatings 1 1 1 2 1<br />

Granules Required (yes, no or optional) OPTIONAL OPTIONAL NO NO<br />

6. REQUIRED DRY FILM THICKNESS: (mils)<br />

Base Coating 24 24 8 – 10 10 – 12 10 – 12<br />

Tom Coating 12 12 8 – 10 10 – 12 8 – 10<br />

7. FILM CURE TIME<br />

Base Coating 24 HOURS 24 HOURS 4 – 6 HOURS 4 – 6 HOURS 4 – 6 HOURS<br />

Top Coating 72 HOURS 4 – 6 HOURS 4 – 6 HOURS 4 – 6 HOURS<br />

8. MINIMUM SLOPE REQUIRED (inches per foot) ¼" ¼" 1/4" 1/4" 1/4"<br />

9. REQUIREMENTS FOR USE OVER:<br />

(X=direct application permitted) (P=primer required)<br />

(T=thermal barrier required)<br />

Concrete Decks P P P P X<br />

Plywood Decks X X T T X<br />

Metal Decks P X X X<br />

Existing Spudded Built-up <strong>Roof</strong>ing X X P P P<br />

Other Coatings P P X X X<br />

10. FLASHING MATERIAL (type or self-flashing) SELF-FLASHING SELF-FLASHING SELF SELF<br />

11. APPLICATION CONDITIONS<br />

Recommended Ambient Air Temperature Range (degrees F) 51-159 51-159 50 – 100 50 – 90 60 – 100<br />

Maximum Permitted Wind Velocity Without Screen (mph) >15 >15 10 10 15<br />

Maximum Permitted Wind Velocity With Wind Screen (mph) >20 >20 15 15 15<br />

12. APPLICATION EQUIPMENT REQUIREMENTS<br />

Single-Component Airless Spray X X X X<br />

Multi-Component Airless Spray X X X X<br />

Other (roller, brush, etc.) X<br />

13. RESTRICTED REGIONS (yes/none) NONE NONE NONE NONE NONE<br />

14. RESTRICTED BUILDING USES (yes/none) NONE NONE NONE NONE NONE<br />

15. RECOMMENDED RECOATING SCHEDULE (years or none) 10 10 5 5 5<br />

16. PHYSICAL PROPERTIES OF THE COATING<br />

Tensile Strength Per ASTM D 412 or Other (psi) 2600 2900 250 – 300 250 – 300 150<br />

Elongation Per ASTM D 412 or Other (%) 300% 190% 250 – 300 250 – 300 150 – 200<br />

Impact Resistance Per ASTM D 2794 or Other (inch lbs)<br />

Accelerated Weathering Per ASTM D 882 or Other (color change) NO CHANGE NO CHANGE NO CHANGE<br />

Heat Aging Per ASTM D 573 or Other (%)<br />

Water Absorption Per ASMT D 570 or Other (%)


Spray Polyurethane Foam-Based Systems; Part 2: Protective Coatings<br />

GARDNER G.E. SEALANTS G.E. SEALANTS G.E. SEALANTS G.E. SEALANTS NATIONAL NEOGARD, A NEOGARD, A NEOGARD, A<br />

ASPHALT CORP/ AND AND AND AND COATINGS DIVISION OF DIVISION OF DIVISION OF<br />

APOC DIVISION ADHESIVES ADHESIVES ADHESIVES ADHESIVES CORP. JONES-BLAIR CO. JONES-BLAIR CO. JONES-BLAIR CO.<br />

STA KOOL SCM 3308 SCM 3304 SCM 3408 SCM 3404 ACRYSHIELD PERMATHANE II PERMATHANE II PERMATHANE<br />

730 BASE COAT TOP COAT BASE COAT TOP COAT FR FR FR<br />

BASE COAT BASE COAT TOP COAT BASE COAT<br />

X<br />

X<br />

X X X X<br />

X X X<br />

NO NO NO NO NO NO<br />

DARK GRAY MEDIUM GRAY DARK GRAY MEDIUM GRAY GRAY, OFF-WHITE, GRAY GRAY, WHITE, BLACK<br />

WHITE, CUSTOM<br />

TAN<br />

#730 SCM3308 SCM3408 ACRYSHIELD PERMATHANE II PERMAGARD<br />

BASE COAT BASE COAT FR 70620 FR 7419<br />

SCM3304 SCM 3404 ACRYSHIELD PERMATHANE II<br />

TOP COAT TOP COAT FR 70611<br />

1 1 1 1 1-2 2<br />

1 1 1 1 1<br />

NO YES YES YES YES OPTIONAL OPTIONAL OPTIONAL<br />

8 - 10 10-12 10 – 12 12 26 26<br />

8 - 10 10-12 10 – 12 12 13<br />

4 - 6 HOURS 20 MINS. .5 – 2 HOURS 2 – 8 HOURS 8-12 HOURS 8-12 HOURS<br />

4 - 6 HOURS 1 HR .5 – 2 HOURS 2 – 8 HOURS 8-12 HOURS<br />

1/4" 1/8" 1/8" 1/8" 1/8" 1/8" NONE NONE NONE<br />

P P P P P P P P P<br />

P P P P P P P P P<br />

X X P P P<br />

X X X X X P P P P<br />

X X X X X X X X X<br />

SELF SELF SELF SELF SELF SELF SELF SELF<br />

50 - 100 40 40 40 40 50 – 110 40 – 110 40 – 110 40 – 110<br />

10 10 10 10 10 15 15 15 15<br />

15 15 15 15 15 25 25 25 25<br />

X X X X X X X<br />

X X<br />

X X ROLLER X X X<br />

NONE NONE NONE NONE NONE NONE NONE NONE NONE<br />

NONE YES YES YES YES YES YES YES YES<br />

5 10 10+ 10+ NONE<br />

250 - 300 500 – 600 500 – 600 200 200 646 1000 1500 400<br />

250 - 300 100 – 150 100 – 150 400 400 402 375 360 500<br />

160 160 160<br />

NO CHANGE NONE NONE NO CHANGE N/A<br />

NONE NONE N./A SLIGHT<br />

100,000<br />

YES YES YES YES YES YES YES YES YES<br />

DISTRIBUTORS DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DIRECT DIRECT DIRECT<br />

13 7 7 10 10 5 8 8 8<br />

T. HYER D. CLARK D. CLARK D. CLARK D. CLARK D. VARAIS ROOFING SALES ROOFING SALES ROOFING SALES<br />

800/237-1155 909/549-0660 909/549-0660 909/549-0660 909/549-0660 805/388–7112 800/321–6588 800/321–6588 800/321–6588<br />

J. HUNTER D. CLARK D. CLARK D. CLARK D. CLARK TECHNICAL DEPT. TECHNICAL DEPT. TECHNICAL DEPT. TECHNICAL DEPT.<br />

800237-1155 909/549-0660 909/549-0660 909/549-0660 909/549-0660 805/388–7112 800/321–6588 800/321–6588 800/321–6588<br />

X X X X<br />

359


Spray Polyurethane Foam-Based Systems; Part 2: Protective Coatings<br />

1. COMPANY NAME NEOGARD, A NEOGARD, A NEOGARD, A PLASTIC PLASTIC<br />

DIVISION OF DIVISION OF DIVISION OF COATINGS COATINGS<br />

JONES-BLAIR CO. JONES-BLAIR CO. JONES-BLAIR CO. CORP. CORP.<br />

2. PRODUCT NAME PERMATHANE ELASTACRYL SILICONE JAXSAN 600 JAXSAN 601<br />

FR FR FR<br />

TOP COAT<br />

3A. COATING DESCRIPTION<br />

Acrylilc X X X<br />

Butyl<br />

Hypalon<br />

Neoprene<br />

Silicone<br />

X<br />

Urethane<br />

X<br />

Vinyl<br />

Modified Asphalt<br />

Other (type)<br />

3B. VAPOR RETARDER (yes, perm rating 1.0) NO NO NO NO NO<br />

3C. COLORS AVAILABLE GRAY, WHITE, GRAY, WHITE GRAY, WHITE, WHITE, GRAY, BRITE WHITE<br />

TAN TAN TAN SPECIAL COLORS<br />

4. BASE COATING (Name of Product) ELASTACRYL SILICONE FR JAXSAN 600 JAXSAN 601<br />

FR 7850<br />

TOP COATING (Name of Product) URETHANE R ELASTACRYL SILICONE FR JAXSAN 600 JAXSAN 601<br />

7441 FR 7850<br />

5. NUMBER OF COATING APPLICATIONS REQUIRED<br />

Base Coatings 1 OR 2 1 OR 2<br />

Top Coatings 2 2-3 2-3<br />

Granules Required (yes, no or optional) OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL<br />

6. REQUIRED DRY FILM THICKNESS: (mils)<br />

Base Coating 15 – 20 15 – 20<br />

Tom Coating 12 27 30 15 – 20 15 – 20<br />

7. FILM CURE TIME<br />

Base Coating 1 – 3 HOURS 2 – 4 HOURS<br />

Top Coating 8-12 HOURS 8-12 HOURS 2-4 HOURS 1 – 3 HOURS 2 – 4 HOURS<br />

8. MINIMUM SLOPE REQUIRED (inches per foot) NONE 1/2" 1/4" NONPONDING NONPONDING<br />

9. REQUIREMENTS FOR USE OVER:<br />

(X=direct application permitted) (P=primer required)<br />

(T=thermal barrier required)<br />

Concrete Decks P P P P<br />

Plywood Decks P P P P<br />

Metal Decks P P P P<br />

Existing Spudded Built-up <strong>Roof</strong>ing P P X X<br />

Other Coatings X X X X<br />

10. FLASHING MATERIAL (type or self-flashing) SELF SELF SELF SELF SELF<br />

11. APPLICATION CONDITIONS<br />

Recommended Ambient Air Temperature Range (degrees F) 40 – 110 60 – 110 40 – 110 50+ 50+<br />

Maximum Permitted Wind Velocity Without Screen (mph) 15 15 15 15 15<br />

Maximum Permitted Wind Velocity With Wind Screen (mph) 25 25 25 25 25<br />

12. APPLICATION EQUIPMENT REQUIREMENTS<br />

Single-Component Airless Spray X X X X X<br />

Multi-Component Airless Spray<br />

Other (roller, brush, etc.) X X X<br />

13. RESTRICTED REGIONS (yes/none) NONE NONE NONE NONE NONE<br />

14. RESTRICTED BUILDING USES (yes/none) YES YES YES YES YES<br />

15. RECOMMENDED RECOATING SCHEDULE (years or none) 10+ 10+ 10+ 10 + 10 +<br />

16. PHYSICAL PROPERTIES OF THE COATING<br />

Tensile Strength Per ASTM D 412 or Other (psi) 2500 125 350 375 375<br />

Elongation Per ASTM D 412 or Other (%) 450 300 200 200 + 200 +<br />

Impact Resistance Per ASTM D 2794 or Other (inch lbs) 160 160 160 98 98<br />

Accelerated Weathering Per ASTM D 882 or Other (color change) SLIGHT SLIGHT SLIGHT NO CHANGE NO CHANGE<br />

Heat Aging Per ASTM D 573 or Other (%)<br />

Water Absorption Per ASMT D 570 or Other (%) 4 20 MAX 100,000 > 100,000 > 50,000 > 6 MILLION > 6 MILLION<br />

22. MANUFACTURER-QUALIFIED APPLICATOR REQUIRED (yes/no) YES YES YES NO NO<br />

23. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DIRECT DIRECT DIRECT DISTRS, DIRECT DISTRS, DIRECT<br />

24. NUMBER OF REGIONAL SERVICE LOCATIONS 8 8 8 10 10<br />

25. SALES INFORMATION, CONTACT: ROOFING SALES ROOFING SALES ROOFING SALES L. WIDDECOMBE III L. WIDDECOMBE III<br />

800/321–6588 800/321–6588 800/321–6588<br />

TECHNICAL INFORMATION, CONTACT: TECHNICAL DEPT. TECHNICAL DEPT. TECHNICAL DEPT. G. WIDDECOMBE G. WIDDECOMBE<br />

26. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/321–6588 800/321–6588 800/321–6588<br />

360


Spray Polyurethane Foam-Based Systems; Part 2: Protective Coatings<br />

PLASTIC QUANTUM QUANTUM QUANTUM QUANTUM QUANTUM QUANTUM QUANTUM QUANTUM<br />

COATINGS COATINGS, INC. COATINGS, INC. COATINGS, INC. COATINGS, INC. COATINGS, INC. COATINGS, INC. COATINGS, INC. COATINGS, INC.<br />

CORP.<br />

JAXSAN 607 FUTURA-THANE FUTURA-FLEX FUTURA-THANE FUTURA-THANE FUTURA-THANE FUTURA-THANE FUTURA-THANE ELASTO-BOND<br />

5007 550 5600 5650 5600 5625 516 801<br />

X<br />

X<br />

X X X X X X X<br />

NO YES YES YES YES YES YES YES YES<br />

WHITE, GRAY, GRAY WHITE, BUFF WHITE BUFF ALUMINUM GRAY BLACK, GRAY<br />

SPECIAL COLORS<br />

OTHER COLORS<br />

JAXSAN 607 SAME FUTURA-THANE SAME FUTURA-THANE SAME FUTURA-THANE SAME SAME<br />

5007 5600 5600<br />

JAXSAN 607 FUTURA-THANE SAME FUTURA-THANE SAME FUTURA-FLEX SAME SAME FUTURA-FLEX<br />

550 5650 5625 550<br />

1 1 1 – 2 1 – 2 1 – 2 1 – 3<br />

1 1 1 1<br />

OPTIONAL NO NO NO NO NO NO OPTIONAL NO<br />

15 – 20 20 – 40 20 – 24 20 – 26 30 – 40 20 – 35<br />

15 – 20 10 10 – 15 10 – 20<br />

1 – 4 HOURS 2 MILLION 3 MILLION+ 5 MILLION+ 500,000 + 1 MILLION+ 2 MILLION+ 2.5 MILLION+ 600,000+ 1 MILLION+<br />

NO YES YES YES YES YES YES YES YES<br />

DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT<br />

10 5 5 5 5 5 5 5 5<br />

L. WIDDECOMBE III B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE<br />

314/521–4100 314/521–4100 314/521–4100 314/521–4100 314/521–4100 314/521–4100 314/521–4100 314/521–4100<br />

G. WIDDECOMBE B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE<br />

314/521–4100 314/521–4100 314/521–4100 314/521–4100 314/521–4100 314/521–4100 314/521–4100 314/521–4100<br />

361


Spray Polyurethane Foam-Based Systems; Part 2: Protective Coatings<br />

1. COMPANY NAME QUANTUM QUANTUM QUANTUM QUANTUM QUANTUM<br />

COATINGS, INC. COATINGS, INC. COATINGS, INC. COATINGS, INC. COATINGS, INC.<br />

2. PRODUCT NAME FUTURA-FLEX ELASTO-BOND ACRO-BOND ACRO-BOND ACRO-BOND<br />

550 820 440 442 448<br />

3A. COATING DESCRIPTION<br />

Acrylilc X X X<br />

Butyl<br />

Hypalon<br />

Neoprene<br />

Silicone<br />

X<br />

Urethane X<br />

Vinyl<br />

Modified Asphalt<br />

Other (type)<br />

3B. VAPOR RETARDER (yes, perm rating 1.0) YES NO NO NO NO<br />

3C. COLORS AVAILABLE WHITE, DARK GRAY, LIGHT BLUE WHITE WHITE, GRAY<br />

OTHER COLORS LIGHT GRAY OTHERS<br />

4. BASE COATING (Name of Product) ELASTO-BOND ELASTO-BOND SAME ACRO-BOND SAME<br />

801 (BASE) 820 440<br />

TOP COATING (Name of Product) FUTURA-THANE 550 ELASTOBOND ACRO-BOND SAME SAME<br />

(TOP) OR SAME 820 442<br />

5. NUMBER OF COATING APPLICATIONS REQUIRED<br />

Base Coatings 1 1 1<br />

Top Coatings 1 1 1 1<br />

Granules Required (yes, no or optional) NO OPTIONAL NO OPTIONAL OPTIONAL<br />

6. REQUIRED DRY FILM THICKNESS: (mils)<br />

Base Coating 10 – 12 1/2 15 – 18 15 – 18<br />

Tom Coating 10 – 15 10 – 12 1/2 15 – 18 15 – 18<br />

7. FILM CURE TIME<br />

Base Coating 3 – 4 HRS @ 75F 1 1/2 – 3 HOURS 1 1/2 – 3 HOURS<br />

Top Coating 6 – 8 HRS @ 75F 3 – 4 HRS @ 75F 1 1/2 – 3 HOURS 1 1/2 – 3 HOURS<br />

8. MINIMUM SLOPE REQUIRED (inches per foot) 1/8" 1/2" 1/2" 1/2" 1/2"<br />

9. REQUIREMENTS FOR USE OVER:<br />

(X=direct application permitted) (P=primer required)<br />

(T=thermal barrier required)<br />

Concrete Decks X P X P X P X P X P<br />

Plywood Decks X P T X P T X P T X P T X P<br />

Metal Decks X P X P X P X P X P<br />

Existing Spudded Built-up <strong>Roof</strong>ing X P X P X P X P X P<br />

Other Coatings P P P P P<br />

10. FLASHING MATERIAL (type or self-flashing) SELF SELF SELF SELF SELF<br />

11. APPLICATION CONDITIONS<br />

Recommended Ambient Air Temperature Range (degrees F) 40 – 110 40 – 110 50+ 50+ 50+<br />

Maximum Permitted Wind Velocity Without Screen (mph) 10 10 10 10 10<br />

Maximum Permitted Wind Velocity With Wind Screen (mph) 15 15 15 15 15<br />

12. APPLICATION EQUIPMENT REQUIREMENTS<br />

Single-Component Airless Spray X X X X X<br />

Multi-Component Airless Spray<br />

Other (roller, brush, etc.) ROLLER, BRUSH ROLLER, BRUSH ROLLER, BRUSH ROLLER, BRUSH ROLLER, BRUSH<br />

13. RESTRICTED REGIONS (yes/none) NONE NONE NONE NONE NONE<br />

14. RESTRICTED BUILDING USES (yes/none) YES YES YES YES YES<br />

15. RECOMMENDED RECOATING SCHEDULE (years or none) 5 – 10 5 – 10 5 – 10 5 – 10 5 – 10<br />

16. PHYSICAL PROPERTIES OF THE COATING<br />

Tensile Strength Per ASTM D 412 or Other (psi) 2700±50 450-550 300 300 300<br />

Elongation Per ASTM D 412 or Other (%) 275±25 140±10 270 270 120<br />

Impact Resistance Per ASTM D 2794 or Other (inch lbs) 62 62<br />

Accelerated Weathering Per ASTM D 882 or Other (color change) NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE<br />

Heat Aging Per ASTM D 573 or Other (%) NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE<br />

Water Absorption Per ASMT D 570 or Other (%) 1.5 0.5±0.1<br />

17. UL 790 FLAMMABILITY CLASS A RATING IN ANY SYSTEM (yes/no) YES YES YES YES YES<br />

18. FOAM INSULATION REQUIREMENTS<br />

Minimum Thickness (inches) 1 – 1 1/2 1 – 1 1/2 1 – 1 1/2 1 – 1 1/2 1 – 1 1/2<br />

Nominal Density Per ASTM D 1622 or Other (lbs/ft 3 ) 2.5 – 3 2.5 – 3 2.5 – 3 2.5 – 3 2.5 – 3<br />

Compressive Strength Per ASTM D 1621 or Other (psi) 40 MIN. 40 MIN. 40 MIN. 40 MIN. 40 MIN.<br />

Closed Cell Content Per ASTM D 2856 or Other (%) 90 MIN. 90 MIN. 90 MIN. 90 MIN. 90 MIN.<br />

19. FOAM AVAILABLE FROM MANUFACTURER (yes/no) NO NO NO NO NO<br />

20. YEAR OF FIRST COMMERCIAL USE 1979 1987 1979 1979 1988<br />

21. NUMBER OF SQUARES INSTALLED (100 ft 2 ) 5 MILLION+ 1.2 MILLION+ 2 MILLION+ 2 MILLION+ 1 MILLION+<br />

22. MANUFACTURER-QUALIFIED APPLICATOR REQUIRED (yes/no) YES YES YES YES YES<br />

23. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT<br />

24. NUMBER OF REGIONAL SERVICE LOCATIONS 5 5 5 5 5<br />

25. SALES INFORMATION, CONTACT: B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE<br />

314/521–4100 314/521–4100 314/521–4100 314/521–4100 314/521-4100<br />

TECHNICAL INFORMATION, CONTACT: B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE<br />

26. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

314/521–4100 314/521–4100 314/521–4100 314/521–4100 314/521-4100<br />

362


Spray Polyurethane Foam-Based Systems; Part 2: Protective Coatings<br />

QUANTUM QUANTUM QUANTUM QUANTUM SWD SWD SWD UNITED UNITED<br />

COATINGS, INC. COATINGS, INC. COATINGS, INC. COATINGS, INC. URETHANE URETHANE URETHANE COATINGS COATINGS<br />

COMPANY COMPANY COMPANY<br />

FUTURA-THANE FUTURA-FLEX 5615 5615 SWD 1929 SWD 1929 F 1929 H DIATHON DIATHON<br />

17060 510 BASE TOP KOOL KOTE KOOL KOTE KOOL KOTE QUICK SET<br />

X X X X X<br />

X X X X<br />

YES YES YES YES 3.5 3.5 3.5 NO NO<br />

ALUMINUM BLACK GRAY ALUMINUM WHITE, GRAY WHITE,GRAY, WHITE, GRAY, PEARL WHITE, MED PEARL WHITE, MED<br />

BUFF BUFF BUFF GRAY, CUSTOM GRAY, CUSTOM<br />

FUTURA-FLEX SAME SAME 5615 SWD 1929 SWD 1929 SWD 1929 DIATHON DIATHON QS<br />

510 BASE KOOL KOTE KOOL KOTE KOOL KOTE<br />

SAME FUTURA-THANE 5615 SAME SAME SAME DIATHON DIATHON QS<br />

17060 TOP<br />

1 – 2 1 – 2 1 1 1 1 1<br />

1 1 1 1 1 1 1 1<br />

OPTIONAL NO OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL<br />

20 – 60 20 – 40 8 - 15 8 - 15 8 - 15 11 MIN. 11 MIN.<br />

10 – 20 10 – 15 8 - 15 8 - 15 8 - 15 11 11 MIN.<br />

4 – 6 HOURS 6 – 8 HRS @ 75F 24 HOURS 24 HOURS 24 HOURS 3 HRS (MED GRAY) 3 HRS (MED GRAY)<br />

6 – 8 HOURS 6 – 8 HRS @ 75F 24 HOURS 24 HOURS 24 HOURS 4 1/2 HRS (WHITE) 4 1/2 HRS (WHITE)<br />

1/8" 1/8" 1/8" 1/8" 1/4" 1/4" 1/4" 1/2" 1/2"<br />

X P X P X P X P P P P P P<br />

X P X P X P X P X X X X X<br />

X P X P X P X P P P P X X<br />

X P X P X P X P X X X X X<br />

X P X P X X P P P X X<br />

SELF SELF SELF SELF SELF SELF SELF SELF SELF<br />

32 – 120 45 – 110 32 – 120 32 – 120 < 50 < 50


Spray Polyurethane Foam-Based Systems; Part 2: Protective Coatings<br />

1. COMPANY NAME UNITED UNITED UNITED UNITED UNITED<br />

COATINGS COATINGS COATINGS COATINGS COATINGS<br />

2. PRODUCT NAME DIATHON DIATHON DIATHON ACRON UNISIL<br />

HIGH TENSILE SOLAR CURE 4500 60<br />

3A. COATING DESCRIPTION<br />

Acrylilc X X X X<br />

Butyl<br />

Hypalon<br />

Neoprene<br />

Silicone<br />

X<br />

Urethane<br />

Vinyl<br />

Modified Asphalt<br />

Other (type)<br />

3B. VAPOR RETARDER (yes, perm rating 1.0) NO NO NO NO NO<br />

3C. COLORS AVAILABLE PEARL WHITE, MED WHITE PEARL WHITE, MED LIGHT GRAY,<br />

GRAY, CUSTOM GRAY, CUSTOM WHITE, CUSTOM<br />

4. BASE COATING (Name of Product) DIATHON HT DIATHON SC DIATHON 4500 ACRON 60 UN ISIL<br />

TOP COATING (Name of Product) DIATHON HT DIATHON SC DIATHON 4500 ACRON 60 UNISIL<br />

5. NUMBER OF COATING APPLICATIONS REQUIRED<br />

Base Coatings 1 1 1 1 1<br />

Top Coatings 1 1 1 1 1<br />

Granules Required (yes, no or optional) OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL<br />

6. REQUIRED DRY FILM THICKNESS: (mils)<br />

Base Coating 11 MIN. 11 MIN. 11 MIN. 11 MIN. 6 – 11 MIN.<br />

Tom Coating 11 MIN. 11 MIN. 11 MIN. 11 MIN. 11 MIN.<br />

7. FILM CURE TIME<br />

Base Coating 3 HRS (MED GRAY) 3 HRS (MED GRAY) 3 HRS (MED GRAY) 2 – 3 HOURS<br />

Top Coating 4 1/2 HRS (WHITE) 4 1/2 HRS (WHITE) 4 1/2 HRS (WHITE) 4 1/2 HRS (WHITE) 2 – 3 HOURS<br />

8. MINIMUM SLOPE REQUIRED (inches per foot) 1/2" 1/2" 1/2" 1/2" 1/2 "<br />

9. REQUIREMENTS FOR USE OVER:<br />

(X=direct application permitted) (P=primer required)<br />

(T=thermal barrier required)<br />

Concrete Decks P P<br />

Plywood Decks X P<br />

Metal Decks X X X X P<br />

Existing Spudded Built-up <strong>Roof</strong>ing X<br />

Other Coatings X P<br />

10. FLASHING MATERIAL (type or self-flashing) SELF SELF SELF SELF SELF<br />

11. APPLICATION CONDITIONS<br />

Recommended Ambient Air Temperature Range (degrees F) 50 – 110 40 – 110<br />

Maximum Permitted Wind Velocity Without Screen (mph) 12 12 12 12 12<br />

Maximum Permitted Wind Velocity With Wind Screen (mph) 20 20 20 20 20<br />

12. APPLICATION EQUIPMENT REQUIREMENTS<br />

Single-Component Airless Spray X X X X X<br />

Multi-Component Airless Spray<br />

Other (roller, brush, etc.) X X X X X<br />

13. RESTRICTED REGIONS (yes/none) NONE NONE<br />

14. RESTRICTED BUILDING USES (yes/none) YES YES YES YES YES<br />

15. RECOMMENDED RECOATING SCHEDULE (years or none) 5 5<br />

16. PHYSICAL PROPERTIES OF THE COATING<br />

Tensile Strength Per ASTM D 412 or Other (psi) 550 250 240 200 650<br />

Elongation Per ASTM D 412 or Other (%) 500 300 145 180 150<br />

Impact Resistance Per ASTM D 2794 or Other (inch lbs)<br />

Accelerated Weathering Per ASTM D 882 or Other (color change) NO CHANGE NO CHANGE NO CHANGE NO CHANGE NO CHANGE<br />

Heat Aging Per ASTM D 573 or Other (%)<br />

Water Absorption Per ASMT D 570 or Other (%)<br />

0.1 MAX<br />

17. UL 790 FLAMMABILITY CLASS A RATING IN ANY SYSTEM (yes/no) YES YES YES YES YES<br />

18. FOAM INSULATION REQUIREMENTS<br />

Minimum Thickness (inches) 1 1<br />

Nominal Density Per ASTM D 1622 or Other (lbs/ft 3 ) 2.5 – 3.0 2.5 – 3.0 2.5 – 3.0 2.5 – 3.0 2.5 – 3.0<br />

Compressive Strength Per ASTM D 1621 or Other (psi) 40 MIN. 40 MIN.<br />

Closed Cell Content Per ASTM D 2856 or Other (%) 90 MIN. 90 MIN.<br />

19. FOAM AVAILABLE FROM MANUFACTURER (yes/no) YES YES YES YES YES<br />

20. YEAR OF FIRST COMMERCIAL USE 1993 1995 1986 1989 1987<br />

21. NUMBER OF SQUARES INSTALLED (100 ft 2 ) 20 MILLION 50 MILLION 20000<br />

22. MANUFACTURER-QUALIFIED APPLICATOR REQUIRED (yes/no) YES YES YES YES YES<br />

23. METHODS OF DISTRIBUTION (distribu<strong>to</strong>rs and/or direct) DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT<br />

24. NUMBER OF REGIONAL SERVICE LOCATIONS 8 4<br />

25. SALES INFORMATION, CONTACT: C. VANGEBLER C. VANGEBLER C. VANGEBLER C. VANGEBLER C. VANGEBLER<br />

800/541-4383 800/541-4383 800/541-4383 800/541-4383 800/541-4383<br />

TECHNICAL INFORMATION, CONTACT: J. CRACE J. CRACE J. CRACE J. CRACE J. CRACE<br />

26. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/541-4383 800/541-4383 800/541-4383 800/541-4383 800/541-4383<br />

364


Spray Polyurethane Foam-Based Systems; Part 2: Protective Coatings<br />

UNITED UNITED UNITED UNITED UNITED UNITED UNITED UNITED<br />

COATINGS COATINGS COATINGS COATINGS COATINGS COATINGS COATINGS COATINGS<br />

ELASTRON ELASTUFF ELASTUFF UNISEAL UNI-TILE ACRILEX 300 UNIBASE ADHERE-IT<br />

858 101 102 EPOXY EPOXY ACRYLIC ACRYLIC EPDM<br />

SEALER SEALER PRIMER ADHES/PRIMER PRIMER<br />

X<br />

X<br />

X<br />

X X X<br />

EPOXY<br />

EPOXY<br />

YES NO NO NO NO NO NO NO<br />

GRAY, TAN MEDIUM GRAY IVORY WHITE, CLEAR, BLACK CLEAR, BLACK LIGHT GRAY TRANSPARENT CLEAR<br />

LIMITED CUSTOM<br />

GREEN<br />

SAME SAME ELASTUFF 101<br />

DIATHON, ELASTUFF 102 SAME<br />

ELASTUFF 102<br />

1 1<br />

1 1<br />

OPTIONAL NO OPTIONAL<br />

15 – 18 17 1/2 – 2 MIN. 1/2 – 2 MIN. 1/2 – 2 MIN.<br />

7 – 9 7<br />

4 – 6 HOURS 6 – 8 HOURS 12 HOURS 3 HOURS 1 – 24 1 – 2 1/2 – 1<br />

8 – 12 HOURS<br />

1/2" 1/2" 1/2"<br />

P P P<br />

X P P<br />

X P P<br />

X<br />

X X X X<br />

SELF SELF SELF SELF<br />

50 – 110 40 – 110 40 – 110 50 – 110 50 – 110 50 – 110 50 – 110 50 – 110<br />

12 12 12 12 12 12 12 12<br />

20 20 20 20 20 20 20 20<br />

X X X X X X X X<br />

X X X X X X X X<br />

NONE NONE NONE NONE NONE NONE NONE NONE<br />

YES YES YES YES YES YES YES YES<br />

5 5 5<br />

300 1000 2500 1000<br />

75 500 400 650<br />

NO CHANGE<br />

1.0 MAX 2.5 MAX<br />

YES YES YES<br />

1 1 1<br />

2.5 – 3.0 2.5 – 3.0 2.5 – 3.0<br />

40 40 40<br />

90 90 90<br />

YES YES YES YES YES YES YES YES<br />

1965 1989 1989 1995 1970 1993 1996 1995<br />

500000 3000 5000<br />

YES YES YES YES YES YES YES YES<br />

DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT<br />

4 4 4 8 8 8 8 8<br />

C. VANGEBLER C. VANGEBLER C. VANGEBLER C. VANGEBLER C. VANGEBLER C. VANGEBLER C. VANGEBLER C. VANGEBLER<br />

800/541-4383 800/541-4383 800/541-4383 800/541-4383 800/541-4383 800/541-4383 800/541-4383 800/541-4383<br />

J. CRACE J. CRACE J. CRACE J. CRACE J. CRACE J. CRACE J. CRACE J. CRACE<br />

800/541-4383 800/541-4383 800/541-4383 800/541-4383 800/541-4383 800/541-4383 800/541-4383 800/541-4383<br />

365


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME AEP-SPAN AEP-SPAN<br />

2. PRODUCT NAME SPAN-LOK (SL) SNAP-SEAM (SN)<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION STANDING SEAM STANDING SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.)<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 22, 24 / KYNAR, BARE 22, 24 / KYNAR, BARE<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.) 0.032, 0.040 / KYNAR 0.032 / KYNAR<br />

Copper (ga.) 16, 20<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 45 45<br />

4D. PANEL WIDTHS (in.) 16, 18 10, 12, 18, 24<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 1/4:12 0.091666667<br />

Solid Decking (required, optional, or not used) OPTIONAL OPTIONAL<br />

Underlayment (type or NA) 30-LB. FELT 30-LB. FELT<br />

6. PANEL PROFILE<br />

Vertical Leg X X<br />

Trapezoidal<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Crimped (45 degrees) 2.3 / F<br />

Roll Formed (180 degrees) 2.3 / F<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

Snap-on Cap<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Snap Together 1-3/4 / F<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed X X<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

Slip Clip<br />

X<br />

Moveable Clip (designed allowable movement, inches) 1<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

X<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1993 1985<br />

Number of Squares Installed 50,000+ 50,000+<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) YES YES<br />

Method of Distribution (distribu<strong>to</strong>rs, direct) DIRECT DIRECT<br />

Number of Regional Service Locations 40 40<br />

For Sales Information, Contact: D. HAGER D. HAGER<br />

For Technical Information, Contact: J. DANIELS J. DANIELS<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS 0/6.24 PSF 0 @ 6.24 PSF<br />

(results or none)<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS 0.013/6.24 PSF 0.0238 @ 6.24 PSF<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS UL-90 UL-90<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

366


Metal <strong>Roof</strong> Panels<br />

AEP-SPAN AEP-SPAN AEP-SPAN AEP-SPAN<br />

STRUCTURAL BATTEN SEAM SN (SBS) HIGH-SEAM (HS) CAP-SEAM (CS) BATTEN SEAM (BS)<br />

YES YES YES YES<br />

YES NO NO NO<br />

STRUCTURAL BATTEN STANDING SEAM STANDING SEAM BATTEN SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

22, 24 / KYNAR, BARE 22, 24 / KYNAR, BARE 22, 24 / KYNAR, BARE 22, 24 / KYNAR, BARE<br />

0..032 / KYNAR 0.032 / KYNAR 0.032, 0.040 / KYNAR 0.032, 0.040 / KYNAR<br />

16, 20 16, 20 16, 20 16, 20<br />

45 45 45 45<br />

10, 12, 18, 24 12, 20 12, 20 16, 24<br />

0.091666667 0.133333333 0.133333333 0.133333333<br />

OPTIONAL REQUIRED REQUIRED REQUIRED<br />

30-LB. FELT 30-LB. FELT 30-LB. FELT 30-LB. FELT<br />

X<br />

X<br />

X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

2 / F 1-1/2 / N<br />

1 / F 2 / N<br />

X X X X<br />

X X X X<br />

X<br />

X X X<br />

X<br />

1985 1980 1989 1978<br />

50,000+ 50,000+ 50,000+ 20,000+<br />

YES YES YES YES<br />

DIRECT DIRECT DIRECT DIRECT<br />

40 40 40 40<br />

D. HAGER D. HAGER D. HAGER D. HAGER<br />

J. DANIELS J. DANIELS J. DANIELS J. DANIELS<br />

0 @ 6.24 PSF NONE 0 @ 6.34 PSF NONE<br />

0.059 @ 6.24 PSF NONE 0 .059 @ 6.24 PSF NONE<br />

UL-90 UL-90 UL-90 NONE<br />

367


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME AEP-SPAN AEP-SPAN<br />

2. PRODUCT NAME BERMUDA SQUARE BATTEN (SB)<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) NO NO<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION BERMUDA STANDING SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.)<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 22, 24 / KYNAR, BARE 24 / KYNAR, BARE<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.)<br />

Copper (ga.)<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 30 45<br />

4D. PANEL WIDTHS (in.) 9.5 12<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 0.175 0.133333333<br />

Solid Decking (required, optional, or not used) REQUIRED REQUIRED<br />

Underlayment (type or NA) 30-LB. FELT 30-LB. FELT<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

Trapezoidal<br />

Batten<br />

Other (specify)<br />

HORIZONTAL<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Roll and Lock 1 / N 1 / N<br />

Snap-on Cap<br />

Snap Together<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed X X<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

Slip Clip X X<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1975 1975<br />

Number of Squares Installed 5,000+ 10,000+<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) YES YES<br />

Method of Distribution (distribu<strong>to</strong>rs, direct) DIRECT DIRECT<br />

Number of Regional Service Locations 40 40<br />

For Sales Information, Contact: D. HAGER D. HAGER<br />

For Technical Information, Contact: J. DANIELS J. DANIELS<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NONE NONE<br />

(results or none)<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS NONE NONE<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS NONE NONE<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

368


Metal <strong>Roof</strong> Panels<br />

AEP-SPAN AEP-SPAN AMERICAN STEEL ARCHITECTURAL METAL<br />

BUILDING CO., INC.<br />

SYSTEMS<br />

STANDING SEAM (SS) SPAN SEAM (SPS) EXPANDEK STANDING SEAM STANDING SEAM II PANELS<br />

YES YES YES YES<br />

NO YES YES YES<br />

STANDING SEAM HINGE LOCKED STAIND SEAM FIELD-LOCKED STANDING SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

22, 24, 26 / DEXSTAR 850, UNFINISHED<br />

24 / KYNAR, BARE 22, 24 / KYNAR, BARE 22, 24, 26 / DEXSTAR 850, UNFINISHED 24, 22 / UNFINISHED, KYNAR 500<br />

0.032, 0.040 / KYNAR<br />

45 45 60 74<br />

12 16, 18 18, 20, 24 24<br />

0.133333333 1/4:12 1/4:12 1/4: 12<br />

REQUIRED OPTIONAL NOT USED OPTIONAL<br />

30-LB. FELT 30-LB. FELT N/A<br />

X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

2, 3 / F<br />

2, 3 / F<br />

2, 3 / F<br />

1 / N<br />

3 / E 3 / F<br />

X<br />

X<br />

X X X<br />

X<br />

1 1 2-1/2<br />

WALLS AND FACADES<br />

1975 1999 1984 1977<br />

10,000+ 10,000+<br />

YES YES NO YES<br />

DIRECT<br />

DIRECT<br />

40 40<br />

D. HAGER D. HAGER S. REINERS K. FISCHER<br />

J. DANIELS J. DANIELS S. HALVORSON J. SAVAGE<br />

NONE 0 @ 6.24 PSF NONE NO LEAKAGE @ 12 PSF<br />

NONE 0.013 @ 6.24 PSF NONE 0.11 SCFM / SF @ 12 PSF<br />

NONE UL - 90 UL-90 UL-90<br />

X<br />

369


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME ARCHITECTURAL METAL ARCHITECTURAL METAL<br />

SYSTEMS<br />

SYSTEMS<br />

2. PRODUCT NAME STANDING SEAM 360 LONG SPAN PANELS<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION FIELD FORMED STANDING SEAM LAPPED SEAMS<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.)<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 24, 22 / UNFINISHED, KYNAR 500 24, 26 / UNFINISHED, KYNAR 500<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.)<br />

Copper (ga.)<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 60 50<br />

4D. PANEL WIDTHS (in.) 24 36<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 1/4:12 1/2: 12<br />

Solid Decking (required, optional, or not used) OPTIONAL OPTIONAL<br />

Underlayment (type or NA)<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

Trapezoidal X X<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Overlapped 1-1/4 / E<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees) 3 / F<br />

Roll and Lock<br />

Snap-on Cap<br />

Snap Together<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches) 2-1/2<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1996 1973<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) YES YES<br />

Method of Distribution (distribu<strong>to</strong>rs, direct)<br />

Number of Regional Service Locations<br />

For Sales Information, Contact: K. FISCHER K. FISCHER<br />

For Technical Information, Contact: J. ROBINSON J. ROBINSON<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NO LEAKAGE @ 12 PSF NO LEAKAGE @ 12 PSF<br />

(results or none)<br />

X<br />

X<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS NO LEAKAGE @ 12 PSF NO LEAKAGE @ 12 PSF<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS UL-90, UL-90,<br />

FM I-60, I-90, I-120 FM I-150<br />

14. SEE APPENDIX IF CHECKED X X<br />

NA=not applicable<br />

370


Metal <strong>Roof</strong> Panels<br />

ARCHITECTURAL METAL ARCHITECTURAL METAL ARCHITECTURAL METAL ARCHITECTURAL METAL<br />

SYSTEMS SYSTEMS SYSTEMS SYSTEMS<br />

MANSARD FASCIA LOC-SEAM PANEL MULTI-RIB PANEL LOC-SEAM 360<br />

YES YES YES YES<br />

NO YES YES YES<br />

FIELD LOCKED STANDING SEAM FIELD-FORMED STANDING SEAM LAPPED SEAM FIELD FORMED STANDING SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

24 / UNFINISHED, KYNAR 500 22, 24 / UNFINISHED, KYNAR 500 29, 26, 24 / UNFINISHED, KYNAR 500 22, 24 / UNFINISHED, KYNAR 500<br />

30 64 47 64<br />

10, 18 12, 16 36 12, 16<br />

3:12 1/4:12 1/2: 12 1/4:12<br />

REQUIRED OPTIONAL OPTIONAL<br />

30-LB. FELT<br />

X X X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

2, 3 / F<br />

3/4 / E<br />

2 / F<br />

1 / F<br />

X<br />

X<br />

X<br />

X<br />

1.25 1.25<br />

1989 1989 1985 1999<br />

YES YES YES YES<br />

K. FISCHER K. FISCHER K. FISCHER K. FISCHER<br />

J. ROBINSON J. ROBINSON J. ROBINSON J. ROBINSON<br />

NONE NO LEAKAGE @ 12 PSF NONE NO LEAKAGE @ 12 PSF<br />

NONE 0.0007 SCFM/SF @ 12 PSF NONE NO LEAKAGE @ 12 PSF<br />

NONE UL-90 UL-90 UL-90,<br />

X X X<br />

FM 1-60 <strong>to</strong> FM I-180<br />

371


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME ARCHITECTURAL METAL ARS INDUSTRIES<br />

SYSTEMS<br />

2. PRODUCT NAME SEAM-LOC SSB<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION FIELD LOCKED STANDING SEAM LOCK FORM BATTEN SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 22, 24, 26 / KYNAR 500, SILICONE<br />

Stainless Steel (ga.) 22, 24<br />

POLYESTER, UNFINISHED<br />

Galvalume (ga.) 22, 24 / UNFINISHED, KYNAR 500 22, 24, 26 / KYNAR 500, SILICONE<br />

Aluminized Steel (ga.) 22, 24<br />

POLYESTER, UNFINISHED<br />

Aluminum (ga.)<br />

0.032, 0.040 / KYNAR 500, SILICONE<br />

POLYESTER, ANODIZED<br />

Copper (ga.) 16, 20<br />

Terne Metal (ga.) 24<br />

Zinc (ga.) 24<br />

4C. MAXIMUM LENGTH (lf.) 40 60<br />

4D. PANEL WIDTHS (in.) 12, 16, 18 8, 12, 16, 18, 20, 24<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 0.133333333 1/4:12<br />

Solid Decking (required, optional, or not used) OPTIONAL OPTIONAL<br />

Underlayment (type or NA)<br />

6. PANEL PROFILE<br />

30-LB. FELT OR EQUIVALENT<br />

Vertical Leg X X<br />

Trapezoidal<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

X<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Crimped (45 degrees) 1-1/2 / F, E<br />

Roll Formed (180 degrees) 1-1/2 / F, E<br />

Double Roll Formed (two 180 degrees) 1-1/2 / F, E<br />

Roll and Lock 2-1/2 / F, E<br />

Snap-on Cap 1-1/2 / N<br />

Snap Together 1.75 / F 1-3/4 / F, E<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

X<br />

CLIP, CONCEALED<br />

Fixed Clip X X<br />

Slip Clip<br />

X<br />

Moveable Clip (designed allowable movement, inches) 1-1/2<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

X<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1999 1984<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) YES YES<br />

Method of Distribution (distribu<strong>to</strong>rs, direct)<br />

YES<br />

Number of Regional Service Locations<br />

For Sales Information, Contact: K. FISCHER 205/836-6777<br />

For Technical Information, Contact: J. ROBINSIN 205/836-6777<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NO LEAKAGE @ 20 PSF NO PENETRATION @ 20 PSF<br />

(results or none)<br />

FOR 15 MINUTES<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS NO LEAKAGE @ 20 PSF LEAKAGE AT SEAM NOT TO EXCEED 0.005<br />

(results or none)<br />

0.005 CFM PSF OF PANEL @ 10 PSF<br />

DIFFERENTIAL PRESSURE<br />

13. FM/UL WIND UPLIFT RATINGS UL-90 UL-90<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

372


Metal <strong>Roof</strong> Panels<br />

ARS INDUSTRIES ARS INDUSTRIES ARS INDUSTRIES ARS INDUSTRIES<br />

SSC SS LB SS 1.5 SS 2.5<br />

YES YES YES YES<br />

NO NO YES YES<br />

SNAP-ON BATTEN BATTEN SEAM LOCK FORM STANDING SEAM SNAP-ON BATTEN<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

22, 24 / KYNAR 500, SILICONE 22, 24 / KYNAR 500, SILICONE 22, 24 / KYNAR 500, SILICONE 22, 24 / KYNAR 500, SILICONE<br />

POLYESTER, UNFINISHED POLYESTER, UNFINISHED POLYESTER, UNFINISHED POLYESTER, UNFINISHED<br />

26 24, 26 22, 24 24 26<br />

24, 26 / KYNAR 500, SILICONE 24, 26 / KYNAR 500, SILICON 22, 24, 26 / KYNAR, SILICON 24, 26 / KYNAR 500, SILICON<br />

POLYESTER, MILL POLYESTER, MILL POLYESTER, MILL POLYESTER, MILL<br />

24, 26 24, 26 22, 24 24, 26<br />

0.032 / KYNAR 500, SILICONE 24, 26 / KYNAR 500, SILICON 0.032, 0.040 / KYNAR 500, SILICON 0.032, 0.040 / KYNAR 500, SILICON<br />

POLYESTER, ANODIZED POLYESTER, ANODIZED POLYESTER, ANODIZED POLYESTER, ANODIZED<br />

16,20 16, 20 16, 20<br />

24, 26 24 24<br />

24, 26 24 24<br />

60 60 60 60<br />

12, 16, 18, 20, 24 8, 12, 16, 18, 20, 24 8, 12, 16, 18, 20, 24 12, 16, 18<br />

0.133333333 0.133333333 1/4:12 1/4:12<br />

REQUIRED REQUIRED OPTIONAL OPTIONAL<br />

30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT<br />

X<br />

X X X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

1-1/2 / F, E<br />

1-1/2 / F, E 2-1/2 / F, E<br />

1 / F 1-1/2 / N 2-1/2<br />

X<br />

X<br />

X<br />

1-1/2 2-1/2<br />

X<br />

X<br />

X<br />

X<br />

1984 1984 1984 1984<br />

YES YES YES YES<br />

YES<br />

205/836-6777 205/836-6777 205/836-6777 205/836-6777<br />

205/836-6777 205/836-6777 205/836-6777 205/836-6777<br />

NONE NONE NO PENETRATION @ 20 PSF NO PENETRATION @ 20 PSF<br />

FOR 15 MINUTES<br />

FOR15 MINUTES<br />

NONE NONE LEAKAGE AT SEAM NOT TO EXCEED LEAKAGE AT SEAM NOT TO EXCEED<br />

0.005 CFM PSF OF PANEL @ 10 PSF 0.005 CFM PSF OF PANEL @ 10 PSF<br />

DIFFERENTAIL PRESSURE<br />

DIFFERENTAIL PRESSURE<br />

NONE NONE UL-90 UL-90<br />

373


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME ATAS INTERNATIONAL, INC. ATAS INTERNATIONAL, INC.<br />

2. PRODUCT NAME MONARCH ROOF PANEL MULTI-PURPOSE PANEL<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION INTEGRAL STANDING AND BATTEN SEAM STRUCTURAL STANDING AND BATTEN SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 22, 24 / KYNAR 500, UNFINISHED 24 / KYNAR, UNFINISHED<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 22, 24 / KYNAR 500, UNFINISHED 24 / KYNAR 500, UNFINISHED<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.) 0.032, 0.040, 0.050 / 0.032, 0.040 / KYNAR 500,<br />

KYNAR 500<br />

ANODIZED<br />

Copper (ga.) 16, 20 16, 20<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 70 40<br />

4D. PANEL WIDTHS (in.) 12, 16 12, 16<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 2:12 3:12<br />

Solid Decking (required, optional, or not used) OPTIONAL OPTIONAL<br />

Underlayment (type or NA) 30-LB. FELT 30-LB. FELT<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

Trapezoidal X X<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

Snap-on Cap<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Snap Together 2, 2-1/2 / F 1-1/4 / N<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

X<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

X<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1981 1977<br />

Number of Squares Installed >100,000 >100,000<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO NO<br />

Method of Distribution (distribu<strong>to</strong>rs, direct) DISTRIBUTORS DISTRIBUTORES<br />

Number of Regional Service Locations 2 2<br />

For Sales Information, Contact: J. BUSH 610/395-8445 J. BUSH 610/395-8445<br />

For Technical Information, Contact: J. BUSH 610/395-8445 J. BUSH 610/395-8445<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NO LEAKAGE @ 10 PSF NO LEAKATE @ 9.75 PSF<br />

(results or none)<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS 0.13 CFM PER SQ FT @ 4.00 PSF 0.11 CFM PER SQ FT @ 4.00 PSF<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS UL-90 UL-90<br />

14. SEE APPENDIX IF CHECKED X X<br />

NA=not applicable<br />

374


Metal <strong>Roof</strong> Panels<br />

ATAS INTERNATIONAL, INC. ATAS INTERNATIONAL, INC. ATAS INTERNATIONAL, INC. ATAS INTERNATIONAL, INC.<br />

PC SNAP-ON SYSTEM PC SNAP-ON SYSTEM METAFOR DUTCH SEAM<br />

YES YES YES YES<br />

NO NO YES YES<br />

SNAP-ON SEAM SNAP-ON BATTEN CORRUGATED STRUCTURAL STANDING SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

24 / KYNAR 500, UNFINISHED 24 / KYNAR 500, UNFINISHED 22, 24 / KYNAR 500, UNFINISHED<br />

24 / KYNAR 500, UNFINISHED 24 / KYNAR 500, UNFINISHED 22, 24 / KYNAR 500, UNFINISHED<br />

0.032, 0.040 / KYNAR 500, 0.032, 0.040 / KYNAR 500, 0.032, 0.040 / KYNAR 500 0.032, 0.040 / KYNAR 500,<br />

ANODIZED ANODIZED ANODIZED<br />

16, 20 16, 20 16, 20<br />

65 65 40 65<br />

12-5/8, 15-1/4 12-1/2, 16-1/2 12 11, 15, 1-1/4<br />

3:12 3;12 3:12 2:12<br />

OPTIONAL OPTIONAL OPTIONAL OPTIONAL<br />

30-LB. FELT 30-LB. FELT 30-LB. FELT 30-LB. FELT<br />

X<br />

X<br />

SQUARE CORRUGATIONS<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

1-1/4 / N 1-1/2 / N<br />

5/8 / N 1-5/8 / F<br />

X<br />

X<br />

X<br />

X<br />

X X X<br />

X X X<br />

1984 1984 1981 1981<br />

>100,000 >100,000 >100,000 >100,000<br />

NO NO NO NO<br />

DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS DISTRIBUTORS<br />

2 2 2 2<br />

J. BUSH 610/395-8445 J. BUSH 610/395-8445 J. BUSH 610/395-8445 J. BUSH 610/395-8445<br />

J. BUSH 610/395-8445 J. BUSH 610/395-8445 J. BUSH 610/395-8445 J. BUSH 610/395-8445<br />

NONE NONE NONE NO LEAKAGE @12.0 PSF (69 MPH)<br />

NONE NONE NONE 0.08 CFM/FE 2@ 1.57 PSF (25 MPH)<br />

UL-90 NONE UL-90<br />

X X X X<br />

375


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME ATAS INTERNATIONAL, INC. BERRIDGE MANUFACTURING CO.<br />

2. PRODUCT NAME FIELD LOCK SEAM TEE-PANEL<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES NO<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION STANDING SEAM SNAP-ON STANDING SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 22, 24 24 / KYNAR 500, HYLAR 5000<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 24 / KYNAR 500, HYLAR 5000<br />

Aluminized Steel (ga.) 0.032, 0.040<br />

Aluminum (ga.)<br />

Copper (ga.) 16<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 70<br />

4D. PANEL WIDTHS (in.) 14, 18 12-3/4<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 1/2:12 1:12<br />

Solid Decking (required, optional, or not used) OPTIONAL REQUIRED<br />

Underlayment (type or NA) N/A 30-LB. FELT OR EQUIVALENT<br />

6. PANEL PROFILE<br />

Vertical Leg X X<br />

Trapezoidal<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

Crimped (45 degrees)<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Roll Formed (180 degrees)<br />

X<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

Snap-on Cap 1 / F<br />

Snap Together<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

Slip Clip X X<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

X<br />

X<br />

X<br />

Other<br />

FREE-FORM COMPOUND CURVED<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1999 1969<br />

Number of Squares Installed >100<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) YES NO<br />

Method of Distribution (distribu<strong>to</strong>rs, direct)<br />

DISTRIBUTORS<br />

Number of Regional Service Locations 3<br />

For Sales Information, Contact: J. BUSH 610/395-8445 D DOYLE 800/231-8127 G GILLUM 800/669-0009<br />

For Technical Information, Contact: J. BUSH 610/395-8445 R MARKS 800/231-8127<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NO LEAKAGE @ 6.24 PSF<br />

(results or none)<br />

DIFFERENTIAL PRESSURE<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS NO MEASURABLE INFILTRATION<br />

(results or none)<br />

@ STATIC PRESSURE<br />

DIFFERENTIAL OF 1.57 PSF<br />

13. FM/UL WIND UPLIFT RATINGS UL-90 UL-90<br />

14. SEE APPENDIX IF CHECKED X X<br />

NA=not applicable<br />

376


Metal <strong>Roof</strong> Panels<br />

BERRIDGE MANUFACTURING CO. BERRIDGE MANUFACTURING CO. BERRIDGE MANUFACTURING CO. BERRIDGE MANUFACTURING CO.<br />

HIGH SEAM TEE-PANEL BATTEN SEAM PANEL ZEE-LOCK DOUBLE-LOCK, DL-1, DL-1.5<br />

YES YES YES YES<br />

YES YES YES YES<br />

SNAP-ON CAP STANDING SEAM BATTEN STANDING SEAM LOCK-FORMED STANDING SEAM LOCK-FORMED STANDING SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

24 / KYNAR 500, HYLAR 5000 24 / KYNAR 500, HYLAR 5000 24 / KYNAR 500, HYLAR 5000 24 / KYNAR 500, HYLAR 5000<br />

24 / KYNAR 500, HYLAR 5000 24 / KYNAR 500, HLAR 5000 24 / KYNAR 500, HYLAR 5000 24 / KYNAR 500, HYLAR 5000<br />

16 16 16 16<br />

18-1/4 16 16 17, 18<br />

1:12 1:12 1/2:12 1/2:12<br />

REQIRED OPTIONAL OPTIONAL OPTIONAL<br />

30-LB. FELT OR EQUIVALENT<br />

30-LB. FELT OR EQUIVALENT<br />

X X X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

2 / F<br />

1, 1-1/2 / N<br />

1, 1-1/2 / F 1-3/4 / F<br />

X X X X<br />

X<br />

X<br />

1970 1970 1989 1987<br />

NO NO NO NO<br />

D DOYLE 800/231-8127 G GILLUM 800/669-0009 D DOYLE 800/231-8127 G GILLUM 800/669-0009 D DOYLE 800/231-8127 G GILLUM 800/669-0009 D DOYLE 800/231-8127 G GILLUM 800/669-0009<br />

R MARKS 800/231-8127 R MARKS 800/231-8127 R MARKS 800/231-8127 R MARKS 800/231-8127<br />

NO LEAKAGE @ 6.24 PSF NONE NO LEAKAGE @ 20 PSF NONE<br />

DIFFERENTIAL PRESSURE<br />

DIFFERENTIAL PRESSURE<br />

NO MEASURABLE INFILTRATION NONE NO MEASUREABLE INFILTRATION NONE<br />

@ STATIC PRESSURE<br />

@ STATIC PRESSURE<br />

DIFFERENTIAL OF 1.57 PSF<br />

DIFFERENTIAL OF 6.24 PSF<br />

UL-90 UL-90 FM I-60, FM I-20 NONE<br />

UL-90<br />

X X X X<br />

377


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME BERRIDGE MANUFACTURING CO. BERRIDGE MANUFACTURING CO.<br />

2. PRODUCT NAME CEE-LOCK PANEL R-PANEL<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION CORRUGATED ROOF PANEL<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 24 / KYNAR 500, HYLAR 5000 24 / KYNAR 500, HYLAR 5000<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 24 / KYNAR 500, HYLAR 5000 24 / KYNAR 500, HYLAR 5000<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.)<br />

Copper (ga.) 16<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 40 40<br />

4D. PANEL WIDTHS (in.) 16-1/2 36<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 1:12 1:12<br />

Solid Decking (required, optional, or not used) OPTIONAL NOT USED<br />

Underlayment (type or NA) 30-LB. FELT OR EQUIVALENT NA<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

X<br />

Trapezoidal<br />

X<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Overlapped 1-1/4 / E<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

Snap-on Cap<br />

Snap Together 1-1/2 / F<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

X<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

Slip Clip X X<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1989 1989<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO NO<br />

Method of Distribution (distribu<strong>to</strong>rs, direct)<br />

Number of Regional Service Locations<br />

For Sales Information, Contact: D DOYLE 800/231-8127 G GILLUM 800/669-0009 D DOYLE 800/231-8127 G GILLUM 800/669-0009<br />

For Technical Information, Contact: R MARKS 800/231-8127 R MARKS 800/231-8127<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NO LEAKAGE @ 20 PSF NONE<br />

(results or none)<br />

DIFFERENTIAL PRESSURE<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS NO MEASUREABLE INFILTRATION NONE<br />

(results or none)<br />

@ STATIC PRESSURE<br />

DIFFERENTIAL OF 6.24 PSF<br />

13. FM/UL WIND UPLIFT RATINGS UL-90 UL-90<br />

14. SEE APPENDIX IF CHECKED X<br />

NA=not applicable<br />

378


Metal <strong>Roof</strong> Panels<br />

BERRIDGE MANUFACTURING CO. BERRIDGE MANUFACTURING CO. BERRIDGE MANUFACTURING CO. BERRIDGE MANUFACTURING CO.<br />

M-PANEL BERMUDA ROOF CURVED FLAT SEAM S-TILE<br />

YES YES YES YES<br />

YES NO NO NO<br />

CORRUGATED ROOF PANEL HORIZONTAL PLANK ROOF SYSTEM CURVED FLAT SEAM S-TILE<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

24 / KYNAR 500, HYLAR 5000 24 / KYNAR 500, HYLAR 5000 24 / KYNAR 500, HYLAR 5000 24 / KYNAR 500, HYLAR 5000<br />

24 / KYNAR 500, HYLAR 5000 24 / KYNAR 500, HYLAR 5000 24 / KYNAR 500, HYLAR 5000 24 / KYNAR 500, HYLAR 5000<br />

16<br />

40 40 40 40<br />

36 8 32-11/16<br />

1:12 3:12 3:12 3:12<br />

NOT USED OPTIONAL REQUIRED OPTIONAL<br />

NA 30-LB. FELT OR EQUIVALENT ICE/WATER GUARD 30-LB. FELT/ICE, WATER GUARD<br />

HORIZONTAL PLANK<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

3/4 / E E<br />

S-TILE<br />

1 / F<br />

X<br />

X<br />

X<br />

X<br />

X<br />

1988 1991 1980 1993<br />

NO NO YES YES<br />

DISTRIBUTORS, DIRECT<br />

DISTRIBUTORS, DIRECT<br />

D DOYLE 800/231-8127 G GILLUM 800/669-0009 D DOYLE 800/231-8127 G GILLUM 800/669-0009 D DOYLE 800/231-8127 G GILLUM 800/669-0009 D DOYLE 800/231-8127 G GILLUM 800/669-0009<br />

R MARKS 800/231-8127 R MARKS 800/231-8127 R MARKS 800/231-8127 R MARKS 800/231-8127<br />

NONE NONE NONE NONE<br />

NONE NONE NONE NONE<br />

NONE UL-90 NONE UL-90<br />

X<br />

379


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME BUTLER ROOF DIVISION BUTLER ROOF DIVISION<br />

2. PRODUCT NAME MR-24 VSR<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION DOUBLE LOCK STANDING SEAM CRIMPED STANDING SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 22, 24 / KYNAR 500, HYLAR 5000 22, 24 / KYNAR 500, HYLAR 5000<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 22, 24 / UNFINISHED 22, 24 / UNFINISHED<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.)<br />

Copper (ga.)<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 60 45<br />

4D. PANEL WIDTHS (in.) 24 16<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 1/4:12 1/2:12<br />

Solid Decking (required, optional, or not used) NOT USED OPTIONAL<br />

Underlayment (type or NA)<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

Trapezoidal<br />

Batten<br />

NA<br />

X<br />

X<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Crimped (45 degrees) 2 / F<br />

Roll Formed (180 degrees) 2-3/4 / F<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

Snap-on Cap<br />

Snap Together<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

X<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches) 2-1/2 2-1/2<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1969 1968<br />

Number of Squares Installed<br />

> 1 BILLION<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) YES YES<br />

Method of Distribution (distribu<strong>to</strong>rs, direct)<br />

Number of Regional Service Locations 6 6<br />

For Sales Information, Contact: 800/998-7663 800/998-7663<br />

For Technical Information, Contact: 800/998-7663 800/998-7663<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NONE NONE<br />

(results or none)<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS NONE NONE<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS FM I-60, FM I-90, FM I-120 FM I-60, FM I-105,<br />

UL-90<br />

UL-90<br />

14. SEE APPENDIX IF CHECKED X X<br />

NA=not applicable<br />

380


Metal <strong>Roof</strong> Panels<br />

BUTLER ROOF DIVISION BUTLER ROOF DIVISION BUTLER ROOF DIVISION BUTLER ROOF DIVISION<br />

CMR-24 BULTERIB II GENESIS 360 GENESIS FASCIA<br />

YES NO YES YES<br />

YES YES NO NO<br />

DOUBLE LOCK STANDING SEAM ROLL FORMED MULTI-RIB DOUBLE LOCK STANDING SEAM INTERLOCKING<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

22, 24, / KYNAR 500, 24, 26, 28 / KYNAR 500, 24 / KYNAR 500, HYLAR 5000 24 / KYNAR, HYLAR 5000<br />

HYLAR 5000 HYLAR 5000<br />

22, 24, / UNFINISHED 24, 26, 28 / UNFINISHED 24 / UNFINISHED 24 / UNFINISHED<br />

24<br />

60 40 45 45<br />

24 36 12, 16, 24 12, 16, 24<br />

1/4:12 1/2:12 1/2:12 3:12<br />

REQUIRED NOT USED REQUIRED REQUIRED<br />

NA<br />

X<br />

X<br />

X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

1-1/2 / E 1 / N<br />

2-3/4 / F 1 / F<br />

X<br />

X<br />

X<br />

2-1/2<br />

1974 1969 1987 1997<br />

YES YES YES YES<br />

6 6<br />

800/998-7663 800/998-7663 800/998-7663 800/998-7663<br />

800/998-7663 800/998-7663 800/998-7663 800/998-7663<br />

NONE<br />

NONE<br />

FM I-60, FM I-90, FM I-120 FM I-90 UL-90 UL-90<br />

UL-90<br />

UL-90<br />

X X X<br />

381


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME CURVELINE, INC. ENGLERT, INC.<br />

2. PRODUCT NAME CURVELINE SERIES 2500<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. Panel Description CURVED TRAPEZOIDAL PANELS MECHANICAL SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 18, 26 / SILICON POLYESTER, CORRESTAN, 22, 24 / KYNAR 550,<br />

DEXSTAR 850, KYNAR 500, UNFINISHED<br />

HYLAR 5000, MILL<br />

Stainless Steel (ga.) 22, 26<br />

Galvalume (ga.) 18, 26 / UNFINISHED 22, 24 / KYNAR 500,<br />

HYLAR 5000, MILL<br />

Aluminized Steel (ga.)<br />

18, 26 / UNFINISHED<br />

Aluminum (ga.) 0.032, 0.040, 0.050 / UNFINISHED, 0.032, 0.040 / KYNAR 500,<br />

ANODIZED HYLAR 5000<br />

Copper (ga.) 16, 20<br />

Terne Metal (ga.) 26<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 30 200<br />

4D. PANEL WIDTHS (in.) 18, 24, 36, 40 12, 16, 18<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 1:12 1/4:12<br />

Solid Decking (required, optional, or not used) NOT USED OPTIONAL<br />

Underlayment (type or NA) NA 30-LB. FELT<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

X<br />

Trapezoidal<br />

X<br />

Batten<br />

Other (specify)<br />

SNAP LOCK<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

E = FIELD APPLIED; N = NONE<br />

Overlapped<br />

Crimped (45 degrees) 2 / F<br />

Roll Formed (180 degrees) 3/4, 1-1/2, 3, 4 / E<br />

Double Roll Formed (two 180 degrees) 3/4, 1-1/2, 3, 4 / E<br />

Roll and Lock<br />

Snap-on Cap<br />

Snap Together 1-1/2, 3 / E<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

X<br />

Through-Fastened, Concealed<br />

X<br />

CLIP, CONCEALED<br />

Fixed Clip X X<br />

Slip Clip<br />

X<br />

Moveable Clip (designed allowable movement, inches) X X<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

X<br />

Tapered<br />

Other<br />

MITERED<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1985 1993<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO YES<br />

Method of Distribution (distribu<strong>to</strong>rs, direct)<br />

DIRECT<br />

Number of Regional Service Locations 10<br />

For Sales Information, Contact: T. HOLMAN. D. KLOCEK K. CORCORAN<br />

For Technical Information, Contact: D. KLOCEK J. TRIPOD<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS 13.24 PSF/15 MIN = 0 15.1 PSF/15 MIN = 0<br />

(results or none)<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS 20 PSF = MAX 0.003 CFM/SQ FT 6.24 PSF/MAX .013 CFM/FT SQ<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS NONE FM I-90,<br />

UL 90<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

382


Metal <strong>Roof</strong> Panels<br />

ENGLERT, INC. ENGLERT, INC. ENGLERT, INC. ENGLERT, INC.<br />

SERIES 1000 SERIES 2000 SERIES 1100 SERIES 2400<br />

YES YES YES YES<br />

NO YES NO YES<br />

SNAP-LOCK SNAP-LOCK SNAP-LOCK STANDING SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

22, 24 / KYNAR 550, 22, 24 / KYNAR 550, 24, 26 / KYNAR 500, 22, 24 / KYNAR 500,<br />

HYLAR 5000, MILL HYLAR 5000, MILL HYLAR 5000, MILL HYLAR 5000, MILL<br />

22, 24 / KYNAR 500, 22, 24 / KYNAR 500, 24, 26 / KYNAR 500, 22, 24 / KYNAR 500,<br />

HYLAR 5000, MILL HYLAR 5000, MILL HYLAR 5000, MILL HYLAR 5000, MILL<br />

0.032 / KYNAR 500, 0.032, 0.040 / KYNAR 500, 0.032 / KYNAR 500, 0.032, 0.040 / KYNAR 500,<br />

HYLAR 5000 HYLAR 5000 HYLAR 5000 HYLAR 5000<br />

16 16, 20 16, 20<br />

26<br />

200 200 200 200<br />

12, 16, 20 12, 16, 18 16 12, 16, 18<br />

3:12 3:12 3:12 1/4:12<br />

REQUIRED OPTIONAL REQUIRED OPTIONAL<br />

30-LB. FELT 30-LB. FELT 30-LB. FELT<br />

X X X X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

1-1/2 / N 1-3/4 / F 1-1/4 / N<br />

2 / N<br />

X X X X<br />

X<br />

1993 1991 1995 1990<br />

NO YES NO NO<br />

DIRECT DIRECT DIRECT DIRECT<br />

10 10 10 10<br />

K. CORCORAN K. CORCORAN K. CORCORAN K. CORCORAN<br />

J. TRIPOD J. TRIPOD J. TRIPOD J. TRIPOD<br />

NONE 15.1 PSF/15 MIN = 0 NONE<br />

NONE 6.24 PSF/MAX .014 CFM/FT SQ NONE<br />

UL-90 UL-90 UL-90 UL-90<br />

383


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME FABRAL FABRAL<br />

2. PRODUCT NAME SLIM SEAM 2-1/2 SSR<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. Panel Description INTEGRAL STANDING SEAM STANDING SEAM ROOF PANEL<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 22, 24 / KYNAR 500 18, 20, 22, 24, 26 / UNFINISHED,<br />

Stainless Steel (ga.)<br />

S.P., KYNAR, VP<br />

18, 20, 22, 24, 26 / MILL<br />

Galvalume (ga.) 22, 24 / KYNAR 500, UNPAINTED 18, 20, 22, 24, 26 / UNFINISHED,<br />

Aluminized Steel (ga.)<br />

S.P., KYNAR, VP<br />

Aluminum (ga.) 0.032, 0.040 / KYNAR 500 .032, .040, .050 / UNFINISHED,<br />

Copper (ga.) 16, 20 16<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

KYNAR, SP, VP, W/W0 STUCCO EMB.<br />

4C. MAXIMUM LENGTH (lf.) 40 42<br />

4D. PANEL WIDTHS (in.) 12, 16 18<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 1:12 1/2:12<br />

Solid Decking (required, optional, or not used) OPTIONAL OPTIONAL<br />

Underlayment (type or NA)<br />

6. PANEL PROFILE<br />

30-LB. FELT<br />

Vertical Leg X X<br />

Trapezoidal<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Snap-on Cap 2-1/2 / F<br />

Snap Together 1-1/2 / F<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

Slip Clip X X<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1987 1980<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO NO<br />

Method of Distribution (distribu<strong>to</strong>rs, direct)<br />

Number of Regional Service Locations<br />

For Sales Information, Contact: DON HUDSON DON HUDSON<br />

For Technical Information, Contact: BILL CROUCHER BILL CROUCHER<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NO PENETRATION UNDER 5 GAL-PER-HR 5 GAL/HR PER SQ FT PRESSURE<br />

(results or none)<br />

SPARY @ 12.0 PSF PRESSURE<br />

DIFFERENTIAL<br />

DIFFERENTIAL 20 PSF 15 MINUTES<br />

WATER PENETRATION, NONE<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS 0.0 AIR @ 20.0 PSF 0.019 CU FT/MIN PER SQ FT<br />

(results or none)<br />

W/20 PSF PRESSURE<br />

X<br />

13. FM/UL WIND UPLIFT RATINGS UL-90 UL-90<br />

14. SEE APPENDIX IF CHECKED X X<br />

NA=not applicable<br />

384


Metal <strong>Roof</strong> Panels<br />

FABRAL FABRAL FABRAL FABRAL<br />

1-1/2 SSR STAND'N SEAM 3" SNAP-RIB-SSR GRANDCURVE<br />

YES YES NO YES<br />

YES YES YES NO<br />

STANDING SEAM STRUCTURAL DOUBLE-LOCK STANDING SEAM STANDING SEAM SNAP-0N BATTEN SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

24 / SUPRE ALURITE 22, 24 / KYNAR 500 24, 26 / SILICONIZED POLYESTER, 22, 24 / KYNAR 500<br />

KYNAR<br />

22, 24 / KYNAR 500, UNPAINTED 24, 26 / SILICONIZED POLYESTER, 22, 24 / KYNAR 500, UNPAINTED<br />

KYNAR, PLAIN<br />

24, 26 / PLAIN, S.P.,<br />

KYNAR<br />

0.032, 0.040 / KYNAR 500 0.032, 0.040 / KYNAR 500<br />

16, 20 16,20<br />

40 150 42 150<br />

16 12, 16 24 12, 16, 18, 24<br />

1:12 1/2:12 1/2:12 1:12<br />

OPTIONAL OPTIONAL OPTIONAL REQUIRED<br />

30-LB. FELT 30-LB. FELT 30-LB. FELT<br />

X<br />

X<br />

X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

2-1/2 / F<br />

1-1/2 / F 3 / F<br />

1-3/4 , 2<br />

X X X<br />

2<br />

X<br />

1987 1987 1989 1997<br />

NO NO NO NO<br />

DON HUDSON DON HUDSON DON HUDSON DON HUDSON<br />

BILL CROUCHER BILL CROUCHER BILL CROUCHER BILL CROUCHER<br />

NO PENETRATION AT 12 PSF NO PENETRATION UNDER 5 GAL-PER-HR NONE NONE<br />

SPRAY @ 20 PSF DIFFERENTIAL<br />

0.0 @ 20 PSF NO AIR @ 20 PSF NONE NONE<br />

UL-90 UL-90 UL-60, UL-90<br />

X X X X<br />

385


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME FABRAL FABRAL<br />

2. PRODUCT NAME SNAP LOK THIN SEAM<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. Panel Description<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 24, 22 / KYNAR 500 24 / KYNAR 500<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 24, 22 / KYNAR 500 24 / KYNAR 500<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.) 0.032 / KYNAR 500 0.032 / KYNAR 500<br />

Copper (ga.)<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 48 48<br />

4D. PANEL WIDTHS (in.) 16, 18 10, 12, 16, 18<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 1:12 1:12<br />

Solid Decking (required, optional, or not used) OPTIONAL OPTIONAL<br />

Underlayment (type or NA) 30-LB. FELT 30-LB. FELT<br />

6. PANEL PROFILE<br />

Vertical Leg X X<br />

Trapezoidal<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Crimped (45 degrees) 2 / F<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

Snap-on Cap<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Snap Together 1-3/4 / F<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

X<br />

Slip Clip<br />

X<br />

Moveable Clip (designed allowable movement, inches) X / 2<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered X X<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1995 1993<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no)<br />

Method of Distribution (distribu<strong>to</strong>rs, direct)<br />

Number of Regional Service Locations<br />

For Sales Information, Contact: DON HUDSON DON HUDSON<br />

For Technical Information, Contact: BILL CROUCHER BILL CROUCHER<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NONE NONE<br />

(results or none)<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS NONE NONE<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS UL 90 UL 90<br />

14. SEE APPENDIX IF CHECKED X X<br />

NA=not applicable<br />

386


Metal <strong>Roof</strong> Panels<br />

FABRAL FABRAL FABRAL FABRAL<br />

T-RIB MINI T-RIB HIGH SEAM DOUBLE LOCK<br />

YES YES YES YES<br />

YES YES NO NO<br />

STANDING SEAM STANDING SEAM SNAP / STANDING SEAM DOUBLE LOCK / STANDING SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

24 / KYNAR 500 24 / KYNAR 500 24 / KYNAR 500 24 / KYNAR 500<br />

24 / KYNAR 500 24 / KYNAR 500 24 / KYNAR 500 24 / KYNAR 500<br />

0.032 / KYNAR 500 0.032 / KYNAR 500 0.032 / KYNAR 500 0.032 / KYNAR 500<br />

16, 20 16, 20<br />

48 48<br />

12, 16, 18 12, 16, 18<br />

1/2: 12 2:12 2:12 3:12<br />

OPTIONAL OPTIONAL OPTIONAL OPTIONAL<br />

30-LB. FELT 30-LB. FELT 30-LB. FELT 30-LB. FELT<br />

X X X X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

2-1/2 / F 1-1/2 / F<br />

1, 1-1/2<br />

1-1/2 / N<br />

X X X<br />

X / 1<br />

X X X X<br />

1976 1976 1995 1995<br />

NO NO NO NO<br />

DON HUDSON DON HUDSON DON HUDSON DON HUDSON<br />

BILL CROUCHER BILL CROUCHER BILL CROUCHER BILL CROUCHER<br />

NONE NONE NONE NONE<br />

NONE NONE NONE NONE<br />

UL 90 UL 90 UL 90 UL 90<br />

X X X X<br />

387


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME FABRAL FABRAL<br />

2. PRODUCT NAME SNAP ON SEAM SNAP ON BATTEN<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) NO NO<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 24, 22 / KYNAR 500 24, 22 / KYNAR 500<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 24, 22 / KYNAR 500 24, 22 / KYNAR 500<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.) 0.032 / KYNAR 500 0.032 / KYNAR 500<br />

Copper (ga.)<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 48 48<br />

4D. PANEL WIDTHS (in.) 12, 16, 18, 20 12, 16, 18, 20<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 3:12 3:12<br />

Solid Decking (required, optional, or not used) REQUIRED REQUIRED<br />

Underlayment (type or NA) 30-LB. FELT 30-LB. FELT<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

Trapezoidal<br />

Batten X X<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Snap-on Cap 1, 1-3/4 / N 1-3/4 / N<br />

Snap Together<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

X<br />

X<br />

Tapered X X<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1995 1995<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO NONE<br />

Method of Distribution (distribu<strong>to</strong>rs, direct)<br />

Number of Regional Service Locations<br />

For Sales Information, Contact: DON HUDSON DON HUDSON<br />

For Technical Information, Contact: BILL CROUCHER BILL CROUCHER<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NONE NONE<br />

(results or none)<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS NONE NONE<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS UL 90 UL 90<br />

14. SEE APPENDIX IF CHECKED X X<br />

NA=not applicable<br />

388


Metal <strong>Roof</strong> Panels<br />

FOLLANSBEE STEEL FOLLANSBEE STEEL GALVAMET, INC. GALVAMET INC.<br />

TCS II TERNE II GALVALOK I GALVALOK II<br />

YES YES YES YES<br />

NO NO YES YES<br />

DOUBLE LOCK STANDING SEAM DOUBLE LOCK STANDING SEAM STANDING SEAM STANDING SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

22, 24, 26 / BARE, MODIFIED 22, 24, 26 / BARE, MODIFIED,<br />

POLYESTER, KYNAR 500 POLYESTER, KYNAR 500<br />

28, 30 / ACRYLIC SHOP COAT<br />

26, 28 / PREWEATHER WASH COAT ONLY<br />

35 35 45 45<br />

17, 21 17, 21 12, 18, 24 12, 18, 24<br />

3:12 3:12 1/4:12 1/4:12<br />

REQUIRED REQUIRED OPTIONAL OPTIONAL<br />

ROSIN SIZED PAPER ROSIN SIZED PAPER RIGID BOARD, ISO, FLEXIBLE FIBERGLASS RIGID BOARD, ISO, FLEXIBLE FIBERGLASS<br />

X<br />

X<br />

X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

1 / N 1 / N 3 / F<br />

3 / F<br />

X X X<br />

X X 2-1/2 2-1/2<br />

X<br />

X<br />

X<br />

1997 1998 1995 1995<br />

NO<br />

NO<br />

DISTRIBUTORS DISTRIBUTORS DIRECT DIRECT<br />

22 22<br />

J. BONAR J. BONAR J. GEORTNER J. GEORTNER<br />

E. THOMAS E. THOMAS J. GEORTNER J. GEORTNER<br />

NONE NONE NO LEAKAGE @ 4 PSF NO LEAKAGE @ 4 PSF<br />

NONE NONE 0.043 CFM; 0.029 CFM; 0.043 CFM; 0.029 CFM;<br />

0.022 CFM @ 4 PSF 0.022 CFM @ 4 PSF<br />

NONE NONE UL-90 UL-90<br />

389


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME GARLAND CO., INC, THE INNOVATIVE METALS<br />

COMPANY, INC.<br />

2. PRODUCT NAME R-MER LITE SERIES 300 PANELS<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) NO YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION FLAT SEAM STRUCTURAL STANDING SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.)<br />

Stainless Steel (ga.) 24 / UNFINISHED<br />

Galvalume (ga.) 30 / SILICONE MODIFIED POLYESTER, 22, 24 / KYNAR, UNFINISHED<br />

Aluminized Steel (ga.)<br />

FLUOROCARBON, PLASTISOL<br />

Aluminum (ga.)<br />

0.032, 0.040, 0.050 / KYNAR<br />

Copper (ga.)<br />

16, 20 / UNFINISHED<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 100 60<br />

4D. PANEL WIDTHS (in.) 144 12, 16, 18<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 1/4:12 1/2:12<br />

Solid Decking (required, optional, or not used) REQUIRED OPTIONAL<br />

Underlayment (type or NA) NA NA<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

Trapezoidal<br />

Batten<br />

Other (specify) FLAT SEAM BATTEN OPTIONAL<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

X<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Overlapped<br />

E<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

Snap-on Cap 2-3/8 / F<br />

Snap Together 2-3/8 / F<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved X X<br />

Tapered X X<br />

Other X FIELD ROLL<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1980 1985<br />

Number of Squares Installed >100,000 100,000+<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) YES YES<br />

Method of Distribution (distribu<strong>to</strong>rs, direct) DIRECT DIRET<br />

Number of Regional Service Locations 30<br />

For Sales Information, Contact: D. SOKOL 800/321-9336 H.C. HOLLISTER<br />

For Technical Information, Contact: M. HUBER 800/321-9336 G.R. JONES<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NONE 0/20 PSF<br />

(results or none)<br />

X<br />

X<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS NONE .0036 SCFM/20 PSF<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS FM, UL I-60, UL I-90 UL-90, FM I-60, FM I-75, FM I-90<br />

14. SEE APPENDIX IF CHECKED<br />

FM I-75, FM I-120, FM I-135<br />

NA=not applicable<br />

390


Metal <strong>Roof</strong> Panels<br />

INNOVATIVE METALS INNOVATIVE METALS INNOVATIVE METALS IPS INSULATED<br />

COMPANY, INC. COMPANY, INC. COMPANY, INC. PANEL SYSTEMS<br />

SNAP-LOK STANDING SEAM PERM-LOC STANDING SEAM SS PANEL SYSTEM RWP ROOFING PANEL<br />

YES YES YES YES<br />

YES NO NO YES<br />

ARCHITECTURAL STANDING SEAM ARCHITECTURAL STANDING SEAM ARCHITECTURAL STANDING SEAM PRE-INSULATED ROLL-FORMED MULTI-RIB<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

22, 24, 26 / KYNAR 500<br />

SILICON POLYESTER<br />

22, 24 / KYNAR, UNFINISHED 24 / KYNAR, UNFNISHED 24 / KYNAR, UNFINISHED 22, 24, 26 / KYNAR 500, SILICON<br />

POLYESTER UNFINISHED<br />

0.032, 0.040 / KYNAR 0.032 / KYNAR 0.032 / KYNAR<br />

16, 20 / UNFINISHED 16, 20 / UNFINISHED<br />

60 45 45 35<br />

10, 12, 16, 18 13, 21 14-1/2 , 22-1/2 36<br />

1-1/2:12 3:12 3:12 1:12<br />

OPTIONAL REQUIRED REQUIRED NOT USED<br />

30-LB. FELT 30-LB. FELT 30-LB. FELT NA<br />

X X X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

1 -1/4 \ E<br />

1-3/4 / F 7/8 / N<br />

1 / F<br />

X<br />

X X X<br />

X<br />

X X X<br />

X<br />

X<br />

1991 1986 1981 1981<br />

50,000+ 50,000+ 50,000+<br />

YES YES YES NO<br />

DIRECT DIRECT DIRECT DIRECT<br />

30 30 30<br />

H.C. HOLLISTER H.C. HOLLISTER H.C. HOLLISTER A. ANDREWS<br />

G.R. JONES G.R. JONES G.R. JONES R. GAMBLE<br />

0/20 PSF 0/20 PSF NONE<br />

.0022 SCFM/20 PSF 0/577/20 PSF NONE<br />

UL-90 UL-90 UL-90 FM 1-60<br />

391


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME IPS INSULATED MBCI<br />

PANEL SYSTEMS<br />

2. PRODUCT NAME SSP ROOFING PANEL ULTRA-DEK 124<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION PRE-INSULATED ROLL-FORMED<br />

STANDING SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES<br />

STANDING SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 22, 24 / KYNAR 500,<br />

Stainless Steel (ga.)<br />

SILICON POLYESTER<br />

Galvalume (ga.) 22, 24, 26 / KYNAR 500, SILICON 22, 24, 26 / BARE, SIGNATURE 200,<br />

POLYESTER UNFINISHED<br />

300 (PVDF), OR 300 METALLIC<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.)<br />

Copper (ga.)<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 35 50 (STANDARD)<br />

4D. PANEL WIDTHS (in.) 36 12, 18, 24<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 1/4:12 1/4:12<br />

Solid Decking (required, optional, or not used) NOT USED OPTIONAL<br />

Underlayment (type or NA)<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

Trapezoidal X X<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

NA<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Double Roll Formed (two 180 degrees) 2-7/8 / F<br />

Roll and Lock<br />

Snap-on Cap<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Snap Together 2-7/8 / F 3 / F<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches) 1/2 2-1/2 (1-1/4 EACH DIRECTION)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1986 1983<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO YES<br />

Method of Distribution (distribu<strong>to</strong>rs, direct) DIRECT DIRECT<br />

Number of Regional Service Locations 21<br />

For Sales Information, Contact: A. ANDREWS W. DICKINSON<br />

For Technical Information, Contact: R. GAMBLE T. WOLFE<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NO LEAKAGE @ 50 PSF NO LEAKAGE @ 4 PSF<br />

(results or none)<br />

DIFFERENTIAL PRESSURE<br />

X<br />

X<br />

X<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS DIFFERENTIAL PRESSURE 0.022 CFM/SQ FT @ 4 PSF<br />

(results or none)<br />

0.01 CFM/SF @ 40 PSF<br />

13. FM/UL WIND UPLIFT RATINGS UL-90 UL-90<br />

FM 1-75, 1-90<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

392


Metal <strong>Roof</strong> Panels<br />

MBCI MBCI MBCI MBCI<br />

DOULBE-LOK 124 CRAFTSMAN SERIES HIGH BATTEN CRAFTSMAN SERIES LARGE BATTEN CRAFTSMAN SERIES SMALL BATTEN<br />

YES YES YES YES<br />

YES NO NO NO<br />

STANDING SEAM LOCK FORM SEPARATE BATTEN LOCK FORM SEPARATE BATTEN LOCK FORM SEPARATE BATTEN<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

22, 24, 26 / BARE, SIGNATURE 200, 22, 24, 26 / BARE, COLOR BOND, SIGNATURE 22, 24, 26 / BARE, COLOR BOND, SIGNATURE 22, 24, 26 / BARE, COLOR BOND, SIGNATURE<br />

300 (PVDF), OR 300 METALLIC 200, 300 (PVDF), OR 300 METALLIC 200, 300 (PVDF), OR 300 METALLIC 200, 300 (PVDF), OR 300 METALLIC<br />

50 (STANDARD) 50 (STANDARD) 50 (STANDRAD) 50 (STANDRAD)<br />

12, 18, 24 12, 16-1/2 12, 16-1/2 12, 16-1/2<br />

1/4:12 3:12 3:12 3:12<br />

OPTIONAL REQUIRED REQUIRED REQUIRED<br />

30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT<br />

X<br />

X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

3 / F<br />

2 / F 2 / F 1 / F<br />

X X X X<br />

2-1/2 (1-1/4 EACH DIRECTION)<br />

TRANSITION, ROOF TO FASCIA, MANSARD TO SOFFIT TRANSITION, ROOF TO FASCIA, MANSARD TO SOFFIT TRANSITION, ROOF TO FASCIA, MANSARD TO SOFFIT<br />

1983 1983 1983 1983<br />

YES NO NO NO<br />

DIRECT DIRECT DIRECT DIRECT<br />

21 21 21 21<br />

W. DICKINSON W. DICKINSON W. DICKINSON W. DICKINSON<br />

T. WOLFE T. WOLFE T. WOLFE T. WOLFE<br />

NO LEAKAGE @ 4 PSF NO LEAKAGE @ 4 PSF NONE NONE<br />

0.022 CFM/SQ FT @ 4 PSF 0.048 CFM/SQ FT @ 4 PSF; NONE NONE<br />

0.045 CFM/SQ FT<br />

UL-90 UL-90 UL-90 UL-90<br />

393


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME MBCI MBCI<br />

2. PRODUCT NAME LOKSEAM BATTENLOK<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION STANDING SEAM STANDING SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.)<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 22, 24, 26 / BARE, SIGNATURE 200, 22, 24, 26 / BARE, SIGNATURE 200,<br />

Aluminized Steel (ga.)<br />

300 (PVDF), OR 300 METALLIC 300 (PVDF), OR 300 METALLIC<br />

Aluminum (ga.)<br />

Copper (ga.)<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 50 (STANDARD) 50 (STANDARD)<br />

4D. PANEL WIDTHS (in.) 12, 16, 18 12, 16<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 3:12 1/4:12<br />

Solid Decking (required, optional, or not used) OPTIONAL OPTIONAL<br />

Underlayment (type or NA)<br />

6. PANEL PROFILE<br />

30-LB. FELT OR EQUIVALENT<br />

Vertical Leg X X<br />

Trapezoidal<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Double Roll Formed (two 180 degrees) 2 / F<br />

Roll and Lock<br />

Snap-on Cap<br />

Snap Together 1-3/4 / F<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip X X<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

X<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

TRANSITION, ROOF TO FASCIA, MANSARD TO SOFFIT<br />

Year of First Commercial Use 1991 1991<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO YES<br />

Method of Distribution (distribu<strong>to</strong>rs, direct) DIRECT DIRECT<br />

Number of Regional Service Locations 21 21<br />

For Sales Information, Contact: W. DICKINSON W. DICKINSON<br />

For Technical Information, Contact: T. WOLFE T. WOLFE<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NO LEAKAGE @ 1.57 PSF NO LEAKAGE @ 1.57 PSF<br />

(results or none)<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS 0.0160 CFM/SQ FT @ 1.57 PSF 0.000 @ 1.57 PSF<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS UL-90 UL-90<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

394


Metal <strong>Roof</strong> Panels<br />

MBCI MBCI MBCI MBCI<br />

SLIMLINE S-36 SUPERLOK PBR-36<br />

YES YES YES YES<br />

NO YES YES YES<br />

1 X 16 INTERLOCKING ARCHITECTURAL<br />

1-1/2 X 12 X 36 EXPOSED<br />

STANDING SEAM<br />

1-1/4 X 12 X 36 EXPOSED<br />

STANDING SEAM ROOF<br />

THICKNESSES / FINISHES<br />

FASTENER PANEL<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

FASTENER PANEL<br />

THICKNESSES / FINISHES<br />

24, 26, 29 / SMP, UNFINISHED<br />

24, 26, 29 / SMP, PVDF, 22, 24, 26, 29 / SMP, PVDF, BARE 22, 24, 26 / BARE, SIGNATURE 200 26 / BARE, SMP, PVDF,<br />

SIGNATURE 200, 300, 300 METALLIC SIGNATURE 200, 300, 300 METALLIC 300, METALLIC SIGNATURE 200, 300<br />

50 55 50 56<br />

12, 16 36 16, 12 36<br />

3:12 1/2:12 1/2:12 1/2:12<br />

REQUIRED OPTIONAL OPTIONAL OPTIONAL<br />

15-LB. FELT 15-LB. FELT 15-LB. FELT<br />

X<br />

X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

1/2 / F 1-1/4 / F<br />

2 / F<br />

1 / N<br />

X<br />

X<br />

X<br />

X<br />

X<br />

2" (I" EACH DIRECTION)<br />

X<br />

1989 1991 1993 1977<br />

NO NO YES NO<br />

DIRECT DIRECT DIRECT DIRECT<br />

21 21 2 21<br />

W. DICKINSON W. DICKINSON W. DICKINSON W. DICKINSON<br />

T. WOLFE T. WOLFE T. WOLFE T. WOLFE<br />

NONE NONE NONE NONE<br />

NONE NONE 0.007 @ 6.24 PSF NONE<br />

NONE UL-90 UL-90<br />

395


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME MBCI MCELROY METAL INC.<br />

2. PRODUCT NAME 7.2 MASTERLOK-90<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION 1-1/2 X 7.2 X 36 SNAP-ON STANDING SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.)<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 22, 24, 26, 29 / SIGNATURE 200, 300, 22, 24, 26 / KYNAR, UNFINISHED<br />

Aluminized Steel (ga.)<br />

300 METALLIC<br />

Aluminum (ga.)<br />

Copper (ga.)<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 55 50<br />

4D. PANEL WIDTHS (in.) 36 12, 18, 24<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 1/2:12 1/4:12<br />

Solid Decking (required, optional, or not used) OPTIONAL OPTIONAL<br />

Underlayment (type or NA)<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

30-LB. FELT<br />

Trapezoidal X X<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

Snap-on Cap<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Snap Together 3 / F<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

X<br />

Fixed Clip<br />

X<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

X<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1991 1986<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO NO<br />

Method of Distribution (distribu<strong>to</strong>rs, direct) DIRECT DISTRIBUTORS / DIRECT<br />

Number of Regional Service Locations 21 16<br />

For Sales Information, Contact: W. DICKINSON K. GIESEKE<br />

For Technical Information, Contact: T. WOLFE E. OSTEN<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NO PENETRATION AT 12 PSF NO LEAKAGE<br />

(results or none)<br />

W/ 5 GAL/HR (8"/HR)<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS YES 0.02 @ 1.57 PSF<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS UL-90 UL-90<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

396


Metal <strong>Roof</strong> Panels<br />

MCELROY METAL INC. MCELROY METAL INC. MCELROY METAL INC. MCELROY METAL INC.<br />

MEDALLION I & II MEGA-RIB MULTI-RIB MAX-RIB<br />

YES YES YES YES<br />

NO YES YES YES<br />

BATTEN CAP OVERLAPPING OVERLAPPING OVERLAPPING<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

18, 20 / KYNAR, 29 / KYNAR,<br />

UNFINISHED<br />

UNFINISHED<br />

22, 24 / KYNAR, UNFINISHED 22, 24, 26 22, 24, 26, 29 / KYNAR, SILICONIZED 22, 24, 26, 29 / KYNAR, SILICONIZED<br />

POLYESTER, UNFINISHED<br />

POLYESTER, UNFINISHED<br />

0.024, 0.032 / MILL, 0.017, 0.024 / MILL,<br />

STUCCO EMBOSSED<br />

STUCCO EMBOSSED<br />

40 40 49 40<br />

12, 14, 16, 18, 20 36 36 38<br />

0.133333333 0.05 0.05 0.091666667<br />

REQUIRED OPTIONAL OPTIONAL OPTIONAL<br />

30-LB. FELT 30-LB. FELT 30-LB. FELT 30-LB. FELT<br />

X<br />

X X X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

1-1/2 / E 1-1/4 / E 3/4 / E<br />

1, 1-1/2 / N<br />

X<br />

X X X<br />

X<br />

1990 1990 1965 1976<br />

NO NO NO NO<br />

DISTRIBUTORS / DIRECT DISTRIBUTORS / DIRECT DISTRIBUTORS / DIRECT DISTRIBUTORS / DIRECT<br />

16 16 16 16<br />

K. GIESEKE K. GIESEKE K. GIESEKE K. GIESEKE<br />

E. OSTEN E. OSTEN E. OSTEN E. OSTEN<br />

NO LEAKAGE NONE NONE NONE<br />

0.005 @ 1.57 PSF NONE NONE NONE<br />

UL-90 NONE UL-90 NONE<br />

397


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME MCELROY METAL INC. MCELROY METAL INC.<br />

2. PRODUCT NAME MULTI-COR M-COR<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) NO NO<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION OVERLAPPING<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.)<br />

29 / UNFINISHED<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 22, 24, 26 / KYNAR, UNFINISHED 22, 24, 26, 29 / KYNAR, UNFINISHED<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.) 0.024, 0.032 / MILL, 0.024, 0.032 / MILL,<br />

STUCCO EMBOSSED<br />

STUCCO EMBOSSED<br />

Copper (ga.)<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 40 40<br />

4D. PANEL WIDTHS (in.) 29-1/4, 32 34-3/4, 37-3/8<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 0.05 0.091666667<br />

Solid Decking (required, optional, or not used) OPTIONAL OPTIONAL<br />

Underlayment (type or NA) 30-LB. FELT. 30-LB. FELT<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

Trapezoidal<br />

Batten<br />

Other (specify) CORRUGATED CORRUGATED<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Overlapped 1/2 / E<br />

Crimped (45 degrees) 7/8 / E<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

Snap-on Cap<br />

Snap Together<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed X X<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1976 1983<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO NO<br />

Method of Distribution (distribu<strong>to</strong>rs, direct) DISTRIBUTORS / DIRECT DISTRIBUTORS / DIRECT<br />

Number of Regional Service Locations 16 16<br />

For Sales Information, Contact: K. GIESEKE K. GIESEKE<br />

For Technical Information, Contact: E. OSTEN E. OSTEN<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NONE NONE<br />

(results or none)<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS NONE NONE<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS NONE NONE<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

398


Metal <strong>Roof</strong> Panels<br />

MCELROY METAL INC. MERCHANT & EVANS, INC. MERCHANT & EVANS, INC. MERCHANT & EVANS, INC.<br />

MEDALLION-LOK INTERLOCK-18 ZIP RIB B 1515 R<br />

YES YES YES YES<br />

YES YES YES NO<br />

INTERLOCKING INTERLOCKING, MECHANICALLY SEAMED BATTEN SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

22, 24 / KYNAR 500 18, 20, 22, 24 / KYNAR 500 22, 24 / KYNAR 500<br />

24 / MILL<br />

22, 24 / KYNAR 500, UNFINSIHED 22, 24 / KYNAR 500, MILL 18, 20, 22, 24 / KYNAR 500, MILL 22, 24 / KYNAR 500<br />

22, 24 / KYNAR 500, 18, 20, 22, 24 / KYNAR 500, 22, 24 / KYNAR 500<br />

MILL<br />

MILL<br />

0.032, 0.040 / KYNAR 500, 0.032, 0.040, 0.050 / KYNAR 500, 0.032, 0.040 / KYNAR 500,<br />

MILL, ANODIZED MILL, ANODIZED MILL, ANODIZED<br />

16, 20 / MILL 16, 20 / MILL 16, 20 / MILL<br />

0.027 / MILL 0.027 / MILL<br />

40 60 105 60<br />

16, 18 10, 18 12, 16 11, 15, 18, 22<br />

0.133333333 0.05 1/4:12 2;12<br />

OPTIONAL OPTIONAL OPTIONAL REQUIRED<br />

30-LB. FELT NA NA 30-LB. FELT OR EQUIVALENT<br />

X<br />

X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

1-3/4 / F<br />

2 / F 2-1/2 / F<br />

1-1/2 / N<br />

X<br />

X<br />

X X X X<br />

UNLIMITED 39483<br />

X<br />

X X X<br />

X<br />

1993 1991 1964 1971<br />

NO NO YES NO<br />

DISTRIBUTORS / DIRECT<br />

16<br />

K. GIESEKE D. BROWN D. BROWN D. BROWN<br />

E. OSTEN T. THOMPSON T. THOMPSON T. THOMPSON<br />

NO LEAKAGE NO PENETRATION @ 15 PSF NONE<br />

FOR 15 MINUTES<br />

.57 @ 1.57 PSF 0.005 CFM/SQ FT @ 6.24 PSF NONE<br />

DIFFERENTIAL<br />

UL-90 UL-90 UL-90 NONE<br />

X<br />

X<br />

399


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME MERCHANT & EVANS, INC. MERCHANT & EVANS, INC.<br />

2. PRODUCT NAME #114 R # 305<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) NO NO<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION INTEGRAL BATTEN SEAM INTEGRAL STANDING SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 22, 24 / KYNAR 500 22, 24 / KYNAR 500<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 22, 24 / KYNAR 500 22, 24 / KYNAR 500<br />

Aluminized Steel (ga.) 22, 24 / KYNAR 500 22, 24 / KYNAR 500<br />

Aluminum (ga.) 0.032, 0.040 / KYNAR 500, 0.032, 0.040 / KYNAR 500,<br />

MILL, ANODIZED<br />

MILL, ANODIZED<br />

Copper (ga.) 16, 20 / MILL 16, 20 / MILL<br />

Terne Metal (ga.)<br />

Zinc (ga.) 0.027 / MILL 0.027 / MILL<br />

4C. MAXIMUM LENGTH (lf.) 60 60<br />

4D. PANEL WIDTHS (in.) 9-3/4, 13, 17 12, 15-1/4, 19-1/4<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 0.091666667 0.091666667<br />

Solid Decking (required, optional, or not used) REQUIRED REQUIRED<br />

Underlayment (type or NA) 30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

Trapezoidal<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

Snap-on Cap<br />

X<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

X<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Snap Together 1-1/4 / N 1-3/8 / F<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

Slip Clip X X<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1968 1984<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO NO<br />

Method of Distribution (distribu<strong>to</strong>rs, direct)<br />

Number of Regional Service Locations<br />

For Sales Information, Contact: D. BROWN D. BROWN<br />

For Technical Information, Contact: T. THOMPSON T. TH OMPSON<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NONE NO PENETRATION @ 15 PSF<br />

(results or none)<br />

FOR 15 MINUTES<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS NONE 0 CFM @ 6.24 PSF<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS NONE UL-90<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

400


Metal <strong>Roof</strong> Panels<br />

MERCHANT & EVANS, INC. MERCHANT & EVANS, INC. METAL SALES METAL SALES<br />

MANUFACTURING CORP.<br />

MANUFACTURING CORP.<br />

# 306 DOME ROOF SYSTEM (BD 1520) MAGNA-LOC SEAM-LOC 24<br />

YES YES YES YES<br />

NO NO YES YES<br />

BATTEN SEAM BATTEN SEAM STANDING SEAM STANDING SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

22, 24 / KYNAR 500<br />

22, 24 / KYNAR 500, MILL 22, 24 / KYNAR 500 (PVF2), BARE 22, 24 / KYNAR 500 (PVF2), BARE<br />

22, 24 / KYNAR 500<br />

0.032, 0.040 / KYNAR 500, 0.032, 0.040 / KYNAR 500,<br />

MILL, ANODIZED<br />

MILL, ANODIZED<br />

16, 20 / MILL 16, 20 / MILL<br />

0.027 / MILL 0.027 / MILL<br />

45 45 45 45<br />

10-1/8, 14, 17-1/2, 21-1/2, 22 UP TO 46-1/2 16, 18 24<br />

0.091666667 1/4:12 1/2:12 1/4:12<br />

REQUIRED REQUIRED OPTIONAL OPTIONAL<br />

30-LB. FLET OR EQUIVALENT<br />

30-LB. FELT OR EQUIVALENT<br />

X<br />

X<br />

X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

2 / F<br />

2-11/16 / F<br />

1, 1-1/4, 1-1/2, 2 / F 2 / N<br />

X<br />

X<br />

2 2<br />

X<br />

X<br />

X<br />

X<br />

DOME<br />

1989 1990 1998 1979<br />

NO NO YES YES<br />

DIRECT<br />

DIRECT<br />

12 12<br />

D. BROWN D. BROWN D. CUNNINGHAM D. CUNNINGHAM<br />

T. THOMPSON T. THOMPSON D. KIRCHGESSNER D. KIRSCGESSNER<br />

NO PENETRATION @ 15 PSF NO PENETRATION @ 15 PSF NO LEAKAGE NO LEAKAGE<br />

FOR 15 MINUTES<br />

FOR 15 MINUTES<br />

0 CFM @ 6.24 PSF NONE 0.060 CFM/SQ FT 0.060 CFM/SQ FT<br />

UL-90 UL-90 FM, UL-90 UL-90<br />

401


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME PETERSEN ALUMINUM PETERSEN ALUMINUM<br />

CORP.<br />

CORP.<br />

2. PRODUCT NAME INTEGRAL BATTEN REDI-R00F STANDING SEAM<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) NO NO<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION BATTEN STANDING SEAM STANDING SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 24 / KYNAR 500 24 / KYNAR 500<br />

Stainless Steel (ga.)<br />

Galvalume (ga.)<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.) 0.032 / KYNAR 500 0.032 / KYNAR 500<br />

Copper (ga.)<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 45 45<br />

4D. PANEL WIDTHS (in.) 11, 18, 19 12, 18, 20<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 3:12 3:12<br />

Solid Decking (required, optional, or not used) REQUIRED REQUIRED<br />

Underlayment (type or NA) 30-LB. FELT 30-LB. FELT<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

Trapezoidal<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

X<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Roll and Lock 1-1/2 / N<br />

Snap-on Cap<br />

X<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Snap Together 1-1/2 / N<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip X X<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1979 1990<br />

Number of Squares Installed > 100,000 > 100,000<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO NO<br />

Method of Distribution (distribu<strong>to</strong>rs, direct) DISTRIBUTORS, DIRECT DISTRIBUTORS, DIRECT<br />

Number of Regional Service Locations 4 4<br />

For Sales Information, Contact: 800/323-1960 800/323-1960<br />

For Technical Information, Contact: 800/323-1960 800/323-1960<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NO LEAKAGE @ 12 PSF NO LEAKAGE @ 12 PSF<br />

(results or none)<br />

X<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS 0.008 CFM/SQ FT @ 1.57 PSF 0.004 CFM/SQ FT @ 1.57 PSF<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS UL-90 UL-90<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

402


Metal <strong>Roof</strong> Panels<br />

PETERSEN ALUMINUM PETERSEN ALUMINUM PETERSEN ALUMINUM PETERSEN ALUMINUM<br />

CORP. CORP. CORP. CORP.<br />

SNAP-ON STANDING SEAM HIGH SNAP-ON \ STANDING SEAM INTEGRAL STANDING SEAM SNAP-ON BATTEN<br />

YES YES YES YES<br />

NO NO NO NO<br />

STANDING SEAM STANDING SEAM STANDING SEAM BATTEN STANDING SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

24 / KYNAR 500 24 / KYNAR 500 24 / KYNAR 500 24 / KYNAR 500<br />

0.032 / KYNAR 500 0.032 / KYNAR 500 0.032 / KYNAR 500 0.032 / KYNAR 500<br />

45 45 45 45<br />

12, 16, 18, 20 11, 18, 19 11, 18, 19 11, 12, 18<br />

3:12 3:12 3:12 3:12<br />

REQUIRED REQUIRED REQUIRED REQUIRED<br />

30-LB. FELT 30-LB. FELT 30-LB. FELT 30-LB. FELT<br />

X<br />

X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

1-1/2 / N<br />

1 / N 1-1/2 / N 1-1/2 / N<br />

X X X X<br />

X<br />

X<br />

X X X<br />

1979 1979 1979 1979<br />

> 100,000 > 100,000 > 100,000 > 100,000<br />

NO NO NO NO<br />

DISTRIBUTORS, DIRECT DISTRIBUTORS, DIRECT DISTRIBUTORS, DIRECT DISTRIBUTORS, DIRECT<br />

4 4 4 4<br />

800/323-1960 800/323-1960 800/323-1960 800/323-1960<br />

800/323-1960 800/323-1960 800/323-1960 800/323-1960<br />

NO LEAKAGE @ 12 PSF NO LEAKAGE @ 12 PSF NO LEAKAGE @ 12 PSF NO LEAKAGE @ 12 PSF<br />

0.006 CFM/SQ FT @ 1.57 PSF 0.005 CFM/SQ FT @ 1.57 PSF 0.02 CFM/SQ FT @ 1.57 PSF 0.02 CFM/SQ FT @ 1.57 PSF<br />

UL-90 UL-90 UL-90 UL-90<br />

403


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME PETERSEN ALUMINUM PETERSEN ALUMINUM<br />

CORP.<br />

CORP.<br />

2. PRODUCT NAME REDI-ROOF BATTEN SNAP-CLAD<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) NO YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION BATTEN STANDING SEAM STANDING SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 24 / KYNAR 500 22, 24 / KYNAR 500<br />

Stainless Steel (ga.)<br />

Galvalume (ga.)<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.) 0.032 / KYNAR 500 0.032 / KYNAR 500<br />

Copper (ga.)<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 45 45<br />

4D. PANEL WIDTHS (in.) 12 10, 12, 16, 18<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 3:12 2:12<br />

Solid Decking (required, optional, or not used) REQUIRED OPTIONAL<br />

Underlayment (type or NA) 30-LB. FELT 30-LB. FELT<br />

6. PANEL PROFILE<br />

Vertical Leg X X<br />

Trapezoidal<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Snap-on Cap 1-1/2 / N<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Snap Together 1-3/4 / F<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip X X<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1989 1993<br />

Number of Squares Installed > 100,000 > 100,000<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO NO<br />

Method of Distribution (distribu<strong>to</strong>rs, direct) DISTRIBUTORS, DIRECT DISTRIBUTORS , DIRECT<br />

Number of Regional Service Locations<br />

For Sales Information, Contact: 800/323-1960 800/323-1960<br />

For Technical Information, Contact: 800/323-1960 800/323-1960<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NO LEAKAGE @ 12 PSF NO LEAKAGE @ 12 PSF<br />

(results or none)<br />

X<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS 0.03 CFM/SQ FT @ 1.57 PSF 0.04 CFM/SQ FT @ 1.57 PSF<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS UL-90 UL-90<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

404


Metal <strong>Roof</strong> Panels<br />

STEELOX ROOF STEELOX ROOF STEELOX ROOF STEELOX ROOF<br />

SYSTEMS SYSTEMS SYSTEMS SYSTEMS<br />

STEELOX LRX STEELOX PRX SENTRY TR STEELOX TP<br />

YES YES NO YES<br />

YES YES YES NO<br />

VERTICAL RIB STANDING SEAM STANDING SEAM STANDING SEAM STANDING SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

22, 24 / 70% KYNAR, UNPAINTED 22, 24 / 70% KYNAR, UNPAINTED 22, 24 / 70% KYNAR, UNPAINTED 22, 24 / 70% KYNAR, UNPAINTED<br />

92 92<br />

12 16 24 10, 12, 14, 16<br />

1/4:12 1/4:12 1/2:12 3:12<br />

OPTIONAL OPTIONAL OPTIONAL<br />

NOT REQUIRED NOT REQUIRED ICE AND WATER<br />

X X X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

2 / F 2 / F<br />

F<br />

X<br />

X<br />

X X X X<br />

2 2 2 2<br />

X X X<br />

X X X<br />

X<br />

X<br />

1934 1934 1997 2000<br />

2,000,000,000 2,000,000,000<br />

YES YES YES NO<br />

DIRECT DIRECT DISTRIBUTORS/DIRECT<br />

5 4 4<br />

T. COLBERT 800/800-8136 T. COLBERT 800/800-8136 T. COLBERT 800/800-8136 T. COLBERT 800/800-8136<br />

M. ADE 800/800-8136 M. ADE 800/800-8136 M. ADE 800/800-8136 M. ADE 800/800-8136<br />

NO INFILTRATION<br />

NO INFILTRATION<br />

0.012 CFM/SQ FT @ 6.24 PSF 0.12 CFM/SQ FT @ 6.24 PSF<br />

UL, CLASS 90, UL CLASS 90<br />

FM I-60, FM I-90 FM I-60, I-120<br />

405


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME STEELOX ROOF STEELOX ROOF<br />

SYSTEMS<br />

SYSTEMS<br />

2. PRODUCT NAME STEELOX LS STEELOX CP<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no)<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.)<br />

Stainless Steel (ga.)<br />

Galvalume (ga.) 22, 24 / 70% KYNAR, UNPAINTED 22, 24 / 70% KYNAR, UNPAINTED<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.)<br />

Copper (ga.)<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.)<br />

4D. PANEL WIDTHS (in.) 10, 12, 14, 16 10, 12, 14, 16<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 3:12 3:12<br />

Solid Decking (required, optional, or not used) OPTIONAL OPTIONAL<br />

Underlayment (type or NA) ICE AND WATER ICE AND WATER<br />

6. PANEL PROFILE<br />

Vertical Leg X X<br />

Trapezoidal<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

Overlapped<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

Snap-on Cap<br />

Snap Together<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Fixed Clip X X<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches) 2 2<br />

9. SPECIALTY APPLICATIONS<br />

Curved X X<br />

Tapered X X<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1997 2000<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO NO<br />

Method of Distribution (distribu<strong>to</strong>rs, direct) DISTRIBUTORS/DIRECT DISTRIBUTORS/DIRECT<br />

Number of Regional Service Locations 4 4<br />

For Sales Information, Contact: T. COLBERT 800/800-8136 T. COLBERT 800/800-8136<br />

For Technical Information, Contact: M. ADE 800/800-8136 A<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS<br />

(results or none)<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

406


Metal <strong>Roof</strong> Panels<br />

UNITED STEEL UNITED STEEL UNITED STEEL UNITED STEEL<br />

DECK, INC. DECK, INC. DECK, INC. DECK, INC.<br />

UNI-LOK UNILINE RP UNIRIB C36 SS18 STANDING SEAM<br />

YES YES YES YES<br />

YES YES YES YES<br />

SNAP-TOGETHER STANDING SEAM EXTERIOR EXPOSED FASTENER EXTERIOR EXPOSED FASTENER EXTERIOR EXPOSED FASTENER<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

22, 24, 26 / SILICONIZED POLYESTER, 22, 24, 26 / SILICONIZED POLYESTER, 18, 20, 22, 24 / SILICONIZED POLYESTER, 18, 20, 22, 24 / SILICONIZED POLYESTER,<br />

FLUOROCARBON, PLASTISOL FLUOROCARBON, PLASTISOL FLUOROCARBON, PLASTISOL FLUOROCARBON, PLASTISOL<br />

22, 24, 26 / UNFINISHED 22, 24, 26, / UNFINISHED 22, 24, / UNFINISHED 22, 24, / UNFINISHED<br />

22, 24, 26 / UNFINISHED 22, 24, 26 / UNFINISHED<br />

0.032, 0.04, 0.05 / UNFINISHED 0.032, 0.04, 0.05 / UNFINISHED 0.032, 0.04, 0.05 / UNFINISHED<br />

60 40 40 40<br />

24 36 36 18<br />

1/4:12 1:12 1:12 1/2:12<br />

OPTIONAL OPTIONAL OPTIONAL OPTIONAL<br />

30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT<br />

X X X<br />

X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

1-1/4 / E 1-1/2 / E 2-5/16 / E<br />

3 / F<br />

X X X<br />

X<br />

X<br />

2<br />

1984 1978 1978 1987<br />

NO NO NO NO<br />

908/277-1617 908/277-1617 908/277-1617 908/277-1617<br />

J. MATTINGLY J. MATTINGLY J. MATTINGLY J. MATTINGLY<br />

NONE NONE NO LEAKAGE @ 6.24 PSF NONE<br />

NONE NONE 0.012 CFM/SQ FT @ 1.57 PSF NONE<br />

UL-90 UL-90 NONE NONE<br />

407


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME UNITED STEEL UNITED STEEL<br />

DECK, INC.<br />

DECK, INC.<br />

2. PRODUCT NAME UTILITY RIB U230<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES YES<br />

STRUCTURAL APPLICATIONS (yes/no) YES YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION EXTERIOR EXPOSED FASTENER EXTERIOR EXPOSED FASTENER<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 24, 26 / SILICONIZED POLYESTER, 18, 20, 22, 24 / SILICONIZED POLYESTER,<br />

Stainless Steel (ga.)<br />

FLUOROCARBON, PLASTISOL<br />

FLUOROCARBON, PLASTISOL<br />

Galvalume (ga.)<br />

22, 24 / UNFINISHED<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.)<br />

0.032, 0.04, 0.05 / UNFINISHED<br />

Copper (ga.)<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 40 40<br />

4D. PANEL WIDTHS (in.) 30 30<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 3:12 1:12<br />

Solid Decking (required, optional, or not used) OPTIONAL OPTIONAL<br />

Underlayment (type or NA) 30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

Trapezoidal X X<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Overlapped 9/16 / E 2 / E<br />

Crimped (45 degrees)<br />

Roll Formed (180 degrees)<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

Snap-on Cap<br />

Snap Together<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed X X<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1978 1989<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no) NO NO<br />

Method of Distribution (distribu<strong>to</strong>rs, direct)<br />

Number of Regional Service Locations<br />

For Sales Information, Contact: 908/277-1617 908/277-1617<br />

For Technical Information, Contact: J. MATTINGLY J. MATTINGLY<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS NONE NONE<br />

(results or none)<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS NONE NONE<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS NONE NONE<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

408


Metal <strong>Roof</strong> Panels<br />

VINCENT VINCENT VINCENT VINCENT<br />

METAL GOODS METAL GOODS METAL GOODS METAL GOODS<br />

COLORKLAD SYSTEM 1 COLORKLAD - SYSTEM 2 COLORKLAD - SYSTEM 3 COLORKLAD - SYSTEM 4<br />

YES YES YES YES<br />

NO NO NO YES<br />

SNAP SEAM - STANDING SEAM SNAP SEAM - STANDING SEAM SINGLE/DOUBLE LOCK STANDING SEAM SNAP SEAM - STANDING SEAM<br />

THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHES<br />

24 / KYNAR 500, 24 / KYNAR 500, 24 / KYNAR 500, 24 / KYNAR 500,<br />

UNFINISHED UNFINISHED UNFINISHED UNFINISHED<br />

24 / UNFINISHED 24 / UNFINISHED 24 / UNFINISHED 24 / UNFINISHED<br />

24 / UNFINISHED 24 / UNFINISHED 24 / UNFINISHED<br />

0.032 / KYNAR 500 0.032 / KYNAR 500 0.032 / KYNAR 500 0.032 / KYNAR 500<br />

16 16 16 16<br />

40 40 40 40<br />

12, 16, 18, 22 12, 16, 20 12, 16, 20 16, 18<br />

3:12 3;12 3;12 3;12<br />

REQUIRED REQUIRED REQUIRED REQUIRED<br />

30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT<br />

X X X X<br />

HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) / HEIGHT(S) (inches) /<br />

SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE E = FIELD APPLIED; N = NONE<br />

1, 1-1/2 / E<br />

1, 1-1/2 / E<br />

1, 1-1/2 / E<br />

1-1/2 / N 1-3/4 / F<br />

X X X X<br />

X<br />

X<br />

X<br />

1970 1970 1970 1970<br />

NO NO NONE NO<br />

DISTRIBUTORS / DIRECT DISTRIBUTORS / DIRECT DISTRIBUTORS / DIRECT DISTRIBUTORS / DIRECT<br />

45 45 45<br />

R. OEHME 763/717-9000 R. OEHME 763/717-9000 R. OEHME 763/717-9000 R. OEHME 763/717-9000<br />

R. OEHME 763/717-9000 R. OEHME 763/717-9000 R. OEHME 763/717-9000 R. OEHME 763/717-9000<br />

NONE NONE NONE ASTM E 331<br />

NONE NONE NONE ASTM 3 283<br />

UL 1-90 UL 1-90 UL 1-90<br />

409


Metal <strong>Roof</strong> Panels<br />

1. COMPANY NAME VINCENT<br />

METAL GOODS<br />

2. PRODUCT NAME COLORKLAD - SYSTEM 5<br />

3. ARCHITECTURAL APPLICATIONS (yes/no) YES<br />

STRUCTURAL APPLICATIONS (yes/no)<br />

YES<br />

PANEL CONFIGURATION<br />

4A. PANEL DESCRIPTION SINGLE/DOUBLE LOCK STANDING SEAM<br />

4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES<br />

Galvanized Steel (ga.) 24 / KYNAR 500,<br />

UNFINISHED<br />

Stainless Steel (ga.) 24 / UNFINISHED<br />

Galvalume (ga.) 24 / UNFINISHED<br />

Aluminized Steel (ga.)<br />

Aluminum (ga.) 0.032 / KYNAR 500<br />

Copper (ga.) 16<br />

Terne Metal (ga.)<br />

Zinc (ga.)<br />

4C. MAXIMUM LENGTH (lf.) 40<br />

4D. PANEL WIDTHS (in.) 16, 18<br />

5. SYSTEMS REQUIREMENTS<br />

Minimum Slope (in. per ft.) 3;12<br />

Solid Decking (required, optional, or not used)<br />

Underlayment (type or NA)<br />

6. PANEL PROFILE<br />

Vertical Leg<br />

REQUIRED<br />

30-LB. FELT OR EQUIVALENT<br />

X<br />

Trapezoidal<br />

Batten<br />

Other (specify)<br />

7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) /<br />

Overlapped<br />

SEAM SEALANT: F= FACTORY APPLIED;<br />

E = FIELD APPLIED; N = NONE<br />

Crimped (45 degrees) 2 / E, F<br />

Roll Formed (180 degrees) 2 / E, F<br />

Double Roll Formed (two 180 degrees)<br />

Roll and Lock<br />

Snap-on Cap<br />

Snap Together<br />

8. FASTENING METHOD<br />

Through-Fastened, Exposed<br />

Through-Fastened, Concealed<br />

CLIP, CONCEALED<br />

Fixed Clip<br />

Slip Clip<br />

Moveable Clip (designed allowable movement, inches)<br />

9. SPECIALTY APPLICATIONS<br />

Curved<br />

X<br />

Tapered<br />

Other<br />

10. MANUFACTURER/PRODUCT DATA<br />

Year of First Commercial Use 1970<br />

Number of Squares Installed<br />

Licensed Applica<strong>to</strong>r Agreement (yes/no)<br />

Method of Distribution (distribu<strong>to</strong>rs, direct)<br />

NO<br />

DISTRIBUTORS / DIRECT<br />

Number of Regional Service Locations<br />

For Sales Information, Contact: R. OEHME 763/717-9000<br />

For Technical Information, Contact: R. OEHME 763/717-9000<br />

11. ASTM E 1646 WATER PENETRATION TEST RESULTS ASTM E 331<br />

(results or none)<br />

12. ASTM E 1680 (AIR INFILTRATION TEST RESULTS ASTM 3 283<br />

(results or none)<br />

13. FM/UL WIND UPLIFT RATINGS UL 1-90<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

410


Appendix, <strong>Roof</strong> <strong>Coverings</strong><br />

ARCHITECTURAL METAL SYSTEMS<br />

All Architectural Metal Systems’ roof systems are<br />

available in a paragraph Premium 70 Plus paint finish,<br />

which has a Kynar 500 resin. It has a proprietary<br />

high-build primer and special long-life ceramic<br />

pigments. It has a chalk rating no lower than 9 and a<br />

fade no higher than 4 NBS over 20 years. It is<br />

warranted for 25 years based on actual field testing.<br />

ATAS INTERNATIONAL, INC.<br />

Atas International, Inc. offers metal roofing systems in<br />

a wide variety of panel profiles, from standing seam<br />

and batten seam <strong>to</strong> tile configuration. Presently it has<br />

over 27 standard colors available in a fluoropolymer<br />

Kynar 500 coating, in 24-gauge galvanized steel, and<br />

0.032, 0.040, and 0.050 aluminum. Contact Atas<br />

International, Inc. at 610-395-8445 for further<br />

information on its products and applicable warranties.<br />

BAKOR<br />

Bakor is the Canadian division of Henry Company.<br />

For sales, warranty or technical information contact<br />

Don Taylor at 800/387-9598. Bakor’s web site<br />

www.bakor.como can also be used <strong>to</strong> obtain technical<br />

or sales information including specifications, technical<br />

data sheets and details.<br />

BARRETT COMPANY<br />

The Barrett Ram-Tough Elas<strong>to</strong>meric Built-up <strong>Roof</strong>ing<br />

System uniquely combines the elas<strong>to</strong>meric properties<br />

of single-ply with the application techniques of built-up<br />

roofing. The modified asphalt bitumens are<br />

engineered from a select blend of highly refined<br />

unoxidized asphalt and Shell Kra<strong>to</strong>n block copolymer<br />

rubber. Conventional asphalt bitumens and cold<br />

process mastics are available options. The "felts," or<br />

fabric reinforcement, are either polyester, fiberglass,<br />

modified bitumen, or a combination thereof depending<br />

upon specification used. Unlike other rubberized<br />

asphalts, the Ram-Tough KLB-100 and K-312<br />

bitumens can be melted in conventional direct-fired<br />

roofing kettles without degradation, they are<br />

pumpable, and can be applied with conventional hot<br />

dispensers and mops. Flashing details are standard<br />

built-up roofing details generally in conformance with<br />

NRCA standard detail specification plates. A base<br />

sheet is required on uninsulated nailable decks.<br />

Utilizing the Ram-Tough Elas<strong>to</strong>meric Built-up<br />

<strong>Roof</strong>ing Systems, the approved roofing contrac<strong>to</strong>r, in<br />

effect, "manufacturers" in the field his own monolithic,<br />

modified-bitumen sheet without the laps and seams<br />

traditionally associated with preformed modified<br />

bitumen sheets. The completed polyester-reinforced<br />

systems afford high elongation,<br />

exceptional usable stress/strain properties, high<br />

puncture resistance, “self-healing” cold<br />

flow, crack bridging capabilities, exceptional lowtemperature<br />

flexibility, and other performance<br />

features normally associated with elas<strong>to</strong>plastic single<br />

plies.<br />

Because of the uniqueness of each individual<br />

reroofing project, Barrett should be consulted before<br />

writing specifications for actual use in a reroofing<br />

application. Unusual roof situations are also encountered<br />

from time <strong>to</strong> time and design and specification<br />

assistance is available <strong>to</strong> the contrac<strong>to</strong>r, architect,<br />

engineer, or owner upon request for freezer and colds<strong>to</strong>rage<br />

warehouses, high interior humidity conditions,<br />

temporary roofing, and most other unusual roofing<br />

problems.<br />

Barrett does not endorse BSS #55 and<br />

encourages adoption of "strain energy" loadelongation<br />

test criteria (in conformance with NBS-IR<br />

86-3418, Rossiter & Bentz; NBS-IR 86-3347,<br />

Busching, Rossiter & Mathey) as being more relevant<br />

<strong>to</strong> actual in-situ field conditions.<br />

Elas<strong>to</strong>meric interply adhesive exceeds ASTM<br />

6152-97.<br />

BERRIDGE MANUFACTURING CO.<br />

Berridge Tee-Panel, High Seam Tee-Panel, Batten<br />

Seam, Zee-Lock, Double-Lock, Cee-Lock, and<br />

Bermuda <strong>Roof</strong> may be roll formed on site in<br />

continuous lengths with a Berridge portable roll<br />

former.<br />

BITEC, INC.<br />

Bitec Mineral Design MDA and MDS are APP and SBS<br />

pattern design products available in eight different<br />

designs with a variety of color combinations. MDA, an<br />

APP product, can be used when APM-4T is used for<br />

<strong>to</strong>rch application. MDS, an SBS product, can be used<br />

when SPM-4H is used and may be applied with hot<br />

asphalt or SBS modified cold adhesive.<br />

BONDCOTE ROOFING SYSTEMS<br />

Barrett does not endorse BSS #55 and encourages<br />

adoption of "strain energy" load-elongation test<br />

criteria (in conformance with NBS-IR 86-3418,<br />

Rossiter & Bentz; NBS-IR 86-3347, Busching, Rossiter<br />

& Mathey) as being more relevant <strong>to</strong> actual in-situ<br />

field conditions.<br />

BondCote FleeceBond 1000 membrane combines<br />

the proven 350 Series membrane with a high-strength<br />

polyester fleece fabric in the fac<strong>to</strong>ry. FleeceBond<br />

1000 is designed <strong>to</strong> be installed directly over roof<br />

insulation or smooth rigid substrates, such as BUR or<br />

plywood when mechanically fastened. FleeceBond<br />

may also be fully adhered with contact adhesive or<br />

hot asphalt <strong>to</strong> a variety of BondCote-approved<br />

substrates.<br />

All BondCote membranes are available in a variety<br />

of cus<strong>to</strong>m colors under the BondCote Spectrum<br />

product category. Underwriters Labora<strong>to</strong>ries Class A<br />

and B fire ratings are available with a number of<br />

standard colors.<br />

411


BUTLER MANUFACTURING COMPANY<br />

MR-24 is fac<strong>to</strong>ry prepunched and is applied only <strong>to</strong><br />

prepunched or field-drilled structurals. A layer of faced<br />

blanket insulation is placed between the purlins and MR-<br />

24 for energy conservation and <strong>to</strong> eliminate condensation.<br />

CMR-24 utilizes a continuous corrugated metal liner<br />

panel (decking) with rigid insulation board and the double<br />

lock standing seam roof system (MR-24). CMR-24 is<br />

fac<strong>to</strong>ry prepunched and is applied only <strong>to</strong> prepunched or<br />

field-drilled structures. A vapor retarder is placed<br />

between the corrugated liner and the rigid board<br />

insulation.<br />

VSR can be used structurally (over bar joists or purlins<br />

5 feet on center) or directly over decking (steel or wood)<br />

with clip spacing at 30 inches on center. Blanket<br />

insulation should be used when VSR is used without<br />

decking over structural members. Rigid board insulation<br />

(Thermax by Celotex) is preferred over decking.<br />

Genesis 360 is an architectural panel <strong>to</strong> be used<br />

primarily over wood or metal deck. It is a weather tight<br />

standing seam panel system utilizing a Pittsburgh<br />

double-lock seam. Genesis 360 can be installed on<br />

slopes as low as 1/2:12" with a weather tightness<br />

warranty offered. Clip spacing <strong>to</strong> 32". SMACNA details<br />

available.<br />

THE CELOTEX CORP.<br />

Built-up roofing specs: All Celotex built-up roofing specs<br />

are published with prefix letters AGS (e.g., AGS-4-C-G)<br />

indicating use of Celo-Glass AGS Ply Sheet, a premium<br />

glass ply sheet with properties exceeding ASTM D-2178<br />

Type VI and NBS-BSS #55 recommendations. Use of<br />

Celotex Celo-Glass AGS Ply Sheet is required <strong>to</strong> qualify<br />

for Celotex "Specification" Warranty. Celotex APP and<br />

Celotex SBS modified bitumen products exceed the<br />

tensile strength recommendations of NBS-BSS #55.<br />

Other built-up roofing specs are prefixed with the letters<br />

G/A and qualify for warranties other than the specification<br />

warranty.<br />

Celotex base sheets are interchangeable when used<br />

in modified bitumen mopped systems, depending upon<br />

the substrate.<br />

Celotex also has available cold process modified bitumen<br />

systems using Celotex SBS mineral surface cap sheet<br />

with SBS modified bitumen adhesive.<br />

Celotex Hydro S<strong>to</strong>p Vapor Barrier/Venting Base Sheet is<br />

designed for use over lightweight insulating concrete<br />

decks. Refer <strong>to</strong> Celotex literature for details.<br />

CERTAINTEED ROOFING PRODUCTS GROUP –<br />

COMMERICAL ROOFING<br />

Eastern Region: 843/744-7451<br />

Central Region: 972/580-5604<br />

Western Region: 510/606-7434<br />

CONKLIN COMPANY, INC.<br />

Benchmark, Rapid <strong>Roof</strong> III and Polytuff II coating systems<br />

are recommended over spray foam systems. Only<br />

Benchmark is approved when applications require<br />

compliance with ICBO, Fac<strong>to</strong>ry Mutual and Metro Dade<br />

County Florida. Additionally, Hy-Crown (CSPE) single-ply<br />

is ICBO recognized, FM approved and classified by<br />

Underwriters Labora<strong>to</strong>ries. All products comply with<br />

EnergyStar <strong>Roof</strong> Products Program guidelines. For<br />

specific details contact Conklin Building Products Division.<br />

COOLEY ENGINEERED MEMBRANES, INC.<br />

Fiberboard may be used for certain applications. Contact<br />

CEMI for further information.<br />

DERMABIT, WATERPROOFING INDUSTRIES, INC.<br />

Dermabit roofing and waterproofing modified bitumen<br />

membranes are manufactured using state-of-the-art<br />

technology. Dermabit membranes consist of two plies of<br />

APP or SBS modified asphalt reinforced with a one-ply<br />

polyester mat. All APP products are sold under the<br />

Dermabit name. SBS products are sold under the<br />

Elasphalt name. The product number designates the<br />

thickness of the membrane and weight of the reinforcing<br />

mat. Thus 4170 indicates a 4mm membrane with a 170<br />

gram polyester mat.<br />

Dermabit also manufactures and sells on a specialorder<br />

basis self-adhering modified bitumen peel and stick<br />

as well as membranes with different thicknesses, ranging<br />

from 1mm <strong>to</strong> 5mm, different types of reinforcements,<br />

such as fiberglass, fleece, or polyester film or any<br />

combination of the above, depending upon the application<br />

requirement.<br />

Dermabit membranes can be <strong>to</strong>rched, hot mopped,<br />

cold applied, or self-adhered <strong>to</strong> all roof decks, including<br />

metal, wood, or concrete. All Dermabit membranes need<br />

<strong>to</strong> be applied over an asphalt-saturated base sheet or<br />

asphalt base primer. Specification manuals can be<br />

ordered free of charge by Don Clark at 302/652-2740, Fax<br />

302/652-0145.<br />

All Dermabit and Elasphalt 4170 series modified<br />

bitumen membranes have successfully passed material<br />

tests conducted by Underwriters Labora<strong>to</strong>ries (UL) and<br />

Fac<strong>to</strong>ry Mutual (FM). Please refer <strong>to</strong> the appropriate UL<br />

and FM guide manuals for specific designs and ratings.<br />

DIBITEN<br />

Dibiten modified bitumen roofing membranes are APP<br />

modified bitumen bonded <strong>to</strong> a <strong>to</strong>ugh, resilient nonwoven<br />

polyester core material. They are available in both<br />

smooth-surfaced (Dibiten Poly/4 and Dibiten Poly/5) and<br />

slate flake-finished (Dibiten Poly/4.5 Granular) varieties.<br />

Surface color for Dibiten Poly/4 and Dibiten a wide range<br />

412


of colors. All the Dibiten APP products are <strong>to</strong>rch applied. Marshfield, Wisc. (800) 528-0878, Tif<strong>to</strong>n, Ga. (800) 749-<br />

Dibiten modified bitumen membranes are well suited for 8144.<br />

most types of roofing and a variety of waterproofing<br />

applications as well. Dibiten recommends their FIELDS COMPANY, LLC<br />

specifications manual be consulted for application<br />

requirements and details prior <strong>to</strong> application of product. Footnotes for the built-up roofing specification number<br />

Specifications are available for single- or double-layer<br />

1<br />

legend: Refer <strong>to</strong> Fields Product Guide and appropriate<br />

applications. Some specifications require application of<br />

2<br />

roof system template for other sheet specified; only for<br />

roof coatings. UL-listed specifications may be obtained<br />

3<br />

tempor roofs, vapor retarders and foundations; Refer <strong>to</strong><br />

by consulting the most current edition of the Dibiten Fields Product Guide and appropriate roof system<br />

specifications manual, and, because these specifications tempalte for reflective coating options, reflective mineral<br />

are subject <strong>to</strong> continuous change, the technical options and reflective cap sheet options.<br />

department should be consulted for verification of current<br />

status. Dibiten membranes have been used successfully FOAM ENTERPRISES, INC.<br />

in Europe since the late '60s, and in the U.S. since 1978.<br />

Dibiten encourages technical inquiries at their <strong>to</strong>ll free FE 303-2.5, 2.7, 3.0; FE 302-2.5, 2.7, 3.0; and FE 304-<br />

number 800/DIBITEN or by calling 303-978-2867 from 3.0. Spray application techniques and conditions can<br />

outside these areas.<br />

reflect upon the physical properties of sprayed-in-place<br />

foams. These listings show ranges that are obtained from<br />

ERSYSTEMS<br />

spraying the compounds per our application instructions.<br />

ERSystems manufactures and distributes a complete line Please consult our instructions for further application<br />

of elas<strong>to</strong>meric roof systems.<br />

details.<br />

Single Ply: The single-ply systems include Permaweld FE 314.3.0 This system uses new "blowing agents"<br />

CPA heat-welded and EPDM membrane roof systems, and long-term insulation figures are not available at this<br />

accessories, and sealants. PolyBond EPDM and time. Initial R-values show 6.25.<br />

Permaweld CPA Fleece Back Membranes have a nonwoven<br />

polyester fleece backing making each ideal for GACO WESTERN, INC.<br />

cushioning irregular surfaces. PermaVac EPDM and<br />

CPA are vacuum adhesion methods of fastening single- Gaco Western offers 16 different elas<strong>to</strong>meric<br />

ply membranes <strong>to</strong> an airtight substrate utilizing vacuum coatings <strong>to</strong> suite the unique requirements of any roof.<br />

air vents and air distribution strips.<br />

GacoFlex specialty coatings include: A-62, a water-<br />

The Metal <strong>Roof</strong> Res<strong>to</strong>ration System is designed <strong>to</strong> based acrylic/latex for foam, concrete and plywood roofs;<br />

renew a metal roof - protect it from rusting, waterproof all H-25 hypalon for concrete and plywood roofing; S-1000;<br />

seams, fasteners and roof penetrations without fabric or UA-60 alpiphatic urethane; E-5325 rust inhibiting epoxy<br />

tapes, and res<strong>to</strong>re the metallic finish for long term primer for metal roofs; UB-7050 fast-set urethane; UApreservation.<br />

Available as a water-based acrylic system 7000 aliphatic urethane. Gaco Western also offers<br />

or polyurethane system.<br />

specialty SPF: PolyFoam 251/303 which cures <strong>to</strong> heavy<br />

Spray-Applied Polyurethane Foam: The ER Foam System density rigid polyurethane insulation; PolyFoam 275 which<br />

consists of sprayed-in-place polyurethane foam used in cures <strong>to</strong> a medium density rigid insulation; PolyFoam 190<br />

conjunction with ERSystems elas<strong>to</strong>meric coatings. 2.7# for use where ambient temperature is below 55F;<br />

and 3.0# roofing foam and 2.0# residential foam is PolyFoam 240 – two part SPF adheres insulation board<br />

available. ER Foam is typified with high density high and felt-backed single-ply <strong>to</strong> a variety of substrates.<br />

compressive foam with good yield and smooth texture.<br />

Foam is protected for the UV and weather with acrylic G. E. SEALANTS AND ADHESIVES<br />

elas<strong>to</strong>mers (Eraguard 1000), polyurethane elas<strong>to</strong>mers<br />

(Erathane 300), or silicone elas<strong>to</strong>mers (Eraguard 4000). Answers <strong>to</strong> questions 9 and 10 are not applicable <strong>to</strong> the<br />

coating requirement because our coating is applied <strong>to</strong> the<br />

FABRAL<br />

urethane foam. Our specifications do require that<br />

concrete and plywood be primed prior <strong>to</strong> the application<br />

FABRAL's metal roofing panels are offered in a wide array of the urethane foam. Thermal barriers are required <strong>to</strong><br />

of standard Kynar 500 colors, siliconized polyester, and satisfy UL and FM ratings. Priming is optional when<br />

vinyl plastisol. A limited 20-year nonprorated finish spraying urethane <strong>to</strong> metal or <strong>to</strong> an existing BUR. The<br />

warranty is available, covering material and labor on base coat and <strong>to</strong>p coat are identical except for color, and<br />

replacement. Contact FABRAL at Lancaster, Pa. (800) they may be used in reverse if a darker <strong>to</strong>p coat is<br />

477-2741, Jackson, Ga. (800) 884-4484, Gridley, Ill. (800) requested.<br />

451-3974, Idabel, Okla. (800) 926-8509, or Cedar City,<br />

Utah (800) 432-2725, Rathdrum, Id. (888) 432-2725,<br />

413


ICA, INC.<br />

ICA, Inc. provides roofing materials and sytems <strong>to</strong> roofing<br />

contrac<strong>to</strong>rs who have met specified criteria for financial<br />

and professional stability and integrity, and therefore,<br />

qualify <strong>to</strong> participate in ICA’s building owner referral<br />

program. ICA roofing materials are manufactured <strong>to</strong><br />

ICA’s stringent quality specifications and are available<br />

exclusively <strong>to</strong> ICA approved contrac<strong>to</strong>rs. It is the goal of<br />

ICA <strong>to</strong> control both the level of material quality and<br />

installation workmanship in order <strong>to</strong> offer the highest<br />

possible quality roofing system <strong>to</strong> the building owner<br />

community.<br />

HENRY COMPANY<br />

Henry Company has many cold process and maintenance<br />

specifications. Please refer <strong>to</strong> the Henry Company<br />

specification manual or the Henry Company<br />

www.henry.com internet site.<br />

Built-Up <strong>Roof</strong>ing: #605 80 lb. Mineral Surface<br />

Underlayment meets ASTM D3909 and is used as a<br />

buffer sheet and is reverse rolled. #606 80 lb. Mineral<br />

Surface SBS-Modified Underlayment meets ASTM D<br />

3909 and ASTM 5147 and is used as a buffer sheet and<br />

is reverse rolled.<br />

Modified Bitumen: modifiedPLUS bitumen roof systems<br />

are multi-ply consisting of combinations of SBS base, ply<br />

and cap sheets depending on specification and warranty<br />

requirements. Membranes can be applied from 1/8 inch<br />

<strong>to</strong> vertical. PMR systems may be used on dead level.<br />

Good roofing practice calls for a minimum of 1/4 inch<br />

slope on conventional modified bitumen roof systems.<br />

Substrates include most common decks as well as<br />

approved insulations. modifiedPLUS applications<br />

include hot applied, cold applied, <strong>to</strong>rch-welding and selfadhered.<br />

The Endure® roof systems within the<br />

modifiedPLUS family of specifications includes<br />

Monolithic cold process roof coatings for extended<br />

warranty situations.<br />

Consult Henry for the latest UL and FM listings. For all<br />

roof system sales information, contact Walt Mullen at<br />

800/523-0268 or for technical information, contact Skip<br />

Leonard at 800/486-1278. Henry’s web site<br />

www.henry.com can also be used <strong>to</strong> obtain technical or<br />

sales information.<br />

HONEYWELL INTERNATIONAL, INC.<br />

Selected Honeywell roof membrane specifications are<br />

available with a protected roof membrane assembly<br />

thermal overlay incorporating extruded polystyrene<br />

insulation board with aggregate surfacing.<br />

INTERCONTINENTAL COATINGS CORP. (I-CON)<br />

Warranties for these products are currently being revised,<br />

contact manufacturer for information.<br />

KOPPERS<br />

BUR: Other: Felts for Spec #410 and #420 incorporate<br />

coal-tar-impregnated glass fiber felts (Tar-Glas), ASTM<br />

D4490, which is similar <strong>to</strong> ASTM D2178 Type IV, except<br />

that the felts are coal-tar impregnated. Felts for spec<br />

#490 and #495 incorporate coal-tar-impregnated glass<br />

fiber felts (Premium Tar-Glas), ASTM D4490, which is<br />

similar <strong>to</strong> ASTM D2178 Type VI, except that the felts are<br />

coal-tar-impregnated.<br />

Koppers IR Series represents a joint agreement<br />

between Koppers and Dow Chemical Co. for an insulated<br />

roof membrane assembly incorporating Koppers coal-tar<br />

built-up roofing membrane and Dow Chemical Co.<br />

Styrofoam.<br />

Modified Bitumen: Koppers modified bitumen<br />

specifications require a base ply. Multiple plies of Type IV<br />

or Type VI asphalt glass reinforced in asphalt is also<br />

acceptable under SBS membranes in lieu of a base<br />

sheet. Contact Koppers Sales and Service Center at 1-<br />

800-558-2706 for additional information.<br />

MERCHANT & EVANS INC.<br />

Zip Rib structural standing seam roofing has been in use<br />

for over 30 years, with installations from Adak, Alaska <strong>to</strong><br />

the coast of the Caribbean. It is available in steel and<br />

aluminum in both 12-and 16-inch widths. The system<br />

utilizes allowable load spans in accordance with ASTM E-<br />

1592 test procedures, which conservatively depict field<br />

service capabilities, not calculated values that may yield<br />

nonconservative allowable load ranges. We offer design<br />

and engineering assistance for all of our products. In<br />

addition <strong>to</strong> our standard offerings listed, we can offer<br />

cus<strong>to</strong>m profiles and cus<strong>to</strong>m cornices <strong>to</strong> meet specific<br />

aesthetic requirements. All of our products are offered in<br />

multiple gauges and in various materials, including<br />

aluminum, copper, stainless steel, and zinc, as well as<br />

steel. For further information, call 1-800-257-6215.<br />

NATIONAL COATINGS CORP.<br />

Acryshield complies with ASTM D 6083-97A, Standard<br />

Specification For Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing. Acryflex complies with both ASTM C920-98,<br />

Standard Specification for Elas<strong>to</strong>meric Joint Sealants<br />

and Federal Specification TT-S-00230C, Class A.<br />

NORTH CAROLINA FOAM INDUSTRIES<br />

Figures for nominal density per ASTM D 1622 are inplace<br />

values; core values are: System 591-2.5, 2.5;<br />

System 591-2.8, 2.8; and System 692-2.5, 2.5. Systems<br />

591 and 692 are formulated with HCFC 141B as the<br />

blowing agent.<br />

North Carolina Foam Industries offers ten-year<br />

warranties for the NCFI Graveledfoam <strong>Roof</strong>ing System<br />

414


(aggregate-covered polyurethane foam) when<br />

installed according <strong>to</strong> specifications by NCFI qualified<br />

applica<strong>to</strong>rs. The maximum ambient relative humidity<br />

varies with the ambient temperature. NCFI offers a<br />

chart indicating maximum wet bulb temperatures and<br />

maximum relative humidity for ambient temperatures<br />

between 50 and 100 F. The maximum allowable wind<br />

velocity with screen depends on the type of wind<br />

screen and degree of enclosure. Thermal resistance<br />

(R) value varies with the age and condition of all<br />

insulating materials.<br />

PERFORMANCE ROOF SYSTEMS, INC.<br />

Complete information on the Performance <strong>Roof</strong><br />

Systems line of Derbigum APP and Permax SBS<br />

polymer modified bitumen roofing products and their<br />

application is provided inthe Derbigum specifications<br />

and detail book. A video is available <strong>to</strong> roofing<br />

professionals describing the application of Derbigum<br />

and Permax membranes with Permastic cold<br />

adhesive, a system with a 20-year track record.<br />

PLASTIC COATINGS CORPORATION<br />

Jaxsan products include Jaxsan 600, an acrylic<br />

elas<strong>to</strong>mer fibered for extra <strong>to</strong>ughness and <strong>to</strong> enhance<br />

film build potential without mudcracking. Jaxsan 607<br />

is not fibered and may be applied by smaller spray<br />

pumps. Plastic Coatings Corp. offers five and ten<br />

year warranties. Foam primers and metal primers are<br />

also available for use in conjunction with SPF. Call 1-<br />

800-279-9151 for details.<br />

SARNAFIL INC.<br />

G 410: Only Sarnafil G 410 membrane should be<br />

used in fully adhered applications. Reinforced with<br />

nonwoven fiberglass mat, the 410 membrane has<br />

excellent dimensional stability, and a very low<br />

coefficient of thermal expansion, making <strong>to</strong>tal<br />

adhesion possible without shear stresses causing<br />

loss of adhesion. The 410 membrane is available in<br />

a variety of stable colors in addition <strong>to</strong> the standard<br />

white and gray. Adhesives are: Sarnacol 2170, a<br />

solvent-based adhesive and Sarnacol 2121, a waterbased<br />

adhesive that is restricted for use during<br />

temperatures above 40 F and over horizontal waterabsorbent<br />

substrate only. Compatibility of the<br />

membrane with the substrate must be assured; only<br />

approvals required. All seams shall be hot-air<br />

welded. Sarnafil membranes require no fire coatings.<br />

G 476: Sarnafil G 476 membrane should be used<br />

in inverted roof membrane assemblies and plaza deck<br />

waterproofing applications. It is reinforced with a<br />

nonwoven fiberglass mat that provides excellent<br />

dimensional stability. The membrane is formulated<br />

with excellent alkaline resistance. Its integral<br />

reinforcement and hot-air-welded seam provide the<br />

protection against wicking and seam degradation<br />

needed in inverted applications, where moisture is<br />

constantly present on the<br />

membrane surface.<br />

S 327: Sarnafil S 327 membranes should be<br />

used for mechanically fastened applications.<br />

Reinforced with polyester fabric, the S 327 membrane<br />

is specifically de-signed <strong>to</strong> provide the necessary<br />

characteristics of elongation and tensile strength <strong>to</strong><br />

control the stressing of the membrane approved<br />

insulations and substrates provide the code that<br />

occurs as a result of dynamic wind loading. The<br />

fastening technique is determined for each individual<br />

job, and is calculated based on building height,<br />

ground roughness, and wind zone. The fastening<br />

method is special 20-gauge corrosive-resistant plates<br />

or 14-gauge perforated U-shaped galvanized steel<br />

bar secured <strong>to</strong> deck with corrosion-resistant screws or<br />

concrete anchors. Depending on wind uplift<br />

conditions, plates are installed in membrane overlaps<br />

and overlaps are hot-air welded, or the U-shaped bar<br />

is placed on <strong>to</strong>p of membrane at calculated spacings<br />

and sealed with membrane cover strip hot-air welded.<br />

Sarnafil membranes require no fire coating.<br />

SEAMAN CORPORATION<br />

FiberTite <strong>Roof</strong>ing Systems by Seaman Corporation<br />

are made with a proprietary formulation based on<br />

Dupont Elvaloy Kee chemically bonded <strong>to</strong> a dense<br />

weft inserted fabric, made of Dupont Dacron polyester<br />

fibers. FiberTite FRT is manufactured in standard 28<br />

inch and 56 inch conventional rolls, along with a<br />

variety of prefabricated, standard and cus<strong>to</strong>m rolls up<br />

<strong>to</strong> 20 feet by 102 feet. FiberTite FB is manufactured<br />

in standard 54 inch roll goods with a 3 inch selvage<br />

edge. FiberTite membranes are either ballasted,<br />

mechanically fastened or adhered, with proprietary<br />

methods, <strong>to</strong> approved substrates.<br />

Proprietary mechanical attachment is through an<br />

unexposed tab in the standard prefabricate system or<br />

conventional roll good system. Adhered systems<br />

incorporate either prefabricated panels or roll goods<br />

in conjuncion with proprietary adhesives specifically<br />

designed for use with the FiberTite membranes.<br />

Prefabricated and standard accessories, such as<br />

boots, cornes, adhesives and edge details are<br />

available <strong>to</strong> aid in the installation of the FiberTite<br />

<strong>Roof</strong>ing Systems. All field seams are hot welded.<br />

FiberTite <strong>Roof</strong>ing Systems by Seaman Corporation<br />

are installed by authorized applica<strong>to</strong>rs. FiberTite<br />

Technical Cus<strong>to</strong>emr Service provide specification and<br />

design assistance <strong>to</strong> contrac<strong>to</strong>rs, architects,<br />

consultants and owners. For additional information<br />

contact Seaman Corporation at 800/927-8578 or via<br />

e-mail at fibertite.com.<br />

SIPLAST<br />

Siplast developed SBS (Styrene-Butadiene-Styrene)<br />

modified bitumens in 1968, which has exceptional<br />

elongation/recovery properties over a wide range of<br />

temperatures. Many Siplast roofs applied in the early<br />

years of the SBS blend are still in service <strong>to</strong>day.<br />

415


Siplast’s Veral Aluminium Face, Veral Copper and<br />

Veral Stainless Steel SBS Modified Bitumens meet or<br />

exceed ASTM D 6298.<br />

Siplast is part of the Icopal Group, a multi-national<br />

industrial corporation. The Siplast product line<br />

includes systems developed specifically for the varied<br />

design and field requirements of modern construction.<br />

These systems have been applied over all types of<br />

deck constructions in the widely varying climates of<br />

over forty countries, from Canada <strong>to</strong> Saudi Arabia.<br />

Domestically, all Siplast roofing products are<br />

manufactured at its plant in Arkadelphia, Arkansas<br />

and are s<strong>to</strong>cked at nine warehouse locations across<br />

the country.<br />

STEVENS ROOFING SYSTEMS<br />

Stevens EP membrane, America’s first reinforced<br />

TPO roofing membrane, has been available since<br />

1992. They are based on a proprietary thermoplastic<br />

polyolefin (TPO) compound of ethylene and<br />

propylene. The result is a hot-air weldable membrane<br />

offering the best performance characteristics of both<br />

EPDM rubber and PVC, but without the limitations of<br />

either. Stevens EP TPO membrane is available in<br />

black, white, gray, and colors. Test results provided<br />

for Stevens <strong>Roof</strong>ing Systems membrane types<br />

represent typical values.<br />

Stevens EP-Fleece is manufactured with Stevens<br />

EP 0.045 and 0.060 membranes with an additional<br />

layer of high quality polyester fleece bonded <strong>to</strong> the<br />

underside of the membrane.<br />

TAMKO ROOFING PRODUCTS INC.<br />

Awaplan Premium was the first SBS modified asphalt<br />

polyester base roll roofing product in America. Since<br />

1977 Awaplan Premium has been applied on different<br />

types of roofs all over the country. Awaplan Premium<br />

is manufactured in Joplin, MO using the latest in<br />

statistical quality-control methods <strong>to</strong> insure the roofing<br />

contrac<strong>to</strong>r a consistent product. Introduced in June of<br />

1986, Awaplan 170 is a variation of Awaplan Premium<br />

produced on a 180 gram-per-square-meter polyester<br />

mat. Awaplan VersaFlex, Awaflex, and Awaflex FR<br />

are Tamko’s newest addition <strong>to</strong> the Awaplan family.<br />

Tamko produces a complete specfiication manual and<br />

technical literature for your use. For further details,<br />

contact the Technical Services Division in Joplin, MO<br />

at 417/624-6644.<br />

TREMCO INC.<br />

BURmastic 100 (Glass Ply) and BURmastic 200<br />

(Composite Ply) Sheets are cold applied BUR<br />

systems. These ply sheets exceed ASTM D 4601,<br />

Type II. BURmastic 300 Ply Sheet is polyester<br />

reinforced and coated with SBS/SEBS modified<br />

asphalt; no ASTM designation currently exists for this<br />

type of material.<br />

416


Section 2<br />

Rigid Board Insulation


Information on Section 2: Rigid Board Insulation<br />

General Information<br />

Section 2: Rigid Board Insulation in the 2001 edition<br />

of NRCA’s Low-Slope <strong>Roof</strong>ing Materials Guide is<br />

divided in<strong>to</strong> seven primary sections based on rigid<br />

board insulation product type. These primary<br />

sections are as follows:<br />

C Expanded polystyrene<br />

C Extruded polystyrene<br />

C Cellular glass<br />

C Wood fiberboard<br />

C Perlite<br />

C Polyisocyanurate<br />

C Composite<br />

A specific description of each particular rigid board<br />

insulation type and a general description of the<br />

specific information contained within each primary<br />

section are included at the conclusion of this General<br />

Information section.<br />

An index of the manufacturers included in Section 2:<br />

Rigid Board Insulation and locations of their specific<br />

products within this section immediately follows this<br />

Rigid Board Insulation section.<br />

Cellular Glass<br />

Cellular glass insulation board is manufactured as a<br />

rigid insulating material composed of heat-fused,<br />

closed glass cells.<br />

Cellular glass insulation board is available in several<br />

different board sizes and a number of board<br />

thicknesses. It is also available in tapered thickness<br />

boards.<br />

The material standard that applies <strong>to</strong> cellular glass<br />

insulation board is American Society for Testing and<br />

Materials (ASTM) C552, titled “Standard Specification<br />

for Cellular Glass Thermal Insulation.”<br />

Information on cellular glass insulation board is<br />

presented in the guide in the Cellular Glass <strong>Roof</strong><br />

Insulation Board section. Specific listing information<br />

included is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Complies with (applicable ASTM standard)<br />

4. Physical properties<br />

5. Surface treatment<br />

6. Available as tapered material<br />

7. Common available sizes<br />

8. Common available thicknesses/R-values<br />

9. Manufacturing plant location(s)<br />

10. UL “P” design numbers<br />

11. Code acceptance<br />

12. Limitations and/or restrictions<br />

13. See appendix<br />

Users of the guide who are interested in additional<br />

information regarding cellular glass insulation are<br />

encouraged <strong>to</strong> refer <strong>to</strong> The NRCA <strong>Roof</strong>ing and<br />

Waterproofing Manual, Fifth Edition.<br />

Composite<br />

Composite insulation boards consist of multiple layers<br />

of insulation and/or a variety of other board materials,<br />

such as perlite, polyisocyanurate, fiberboard,<br />

plywood, or gypsum board that form a unified, bonded<br />

multi-layer component. Top and/or bot<strong>to</strong>m surfaces<br />

may or may not be coated or impregnated with facer<br />

materials, such as foils, organic felts, glass fibers, and<br />

kraft paper.<br />

Composite insulation board is available in several<br />

different board sizes and a number of board<br />

thicknesses.<br />

Information on composite insulation board is<br />

presented in the guide in the Composite <strong>Roof</strong><br />

Insulation Board section. Specific listing information<br />

included is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Complies with (applicable ASTM standard)<br />

4. Physical properties<br />

5. Surface treatment<br />

6. Available as tapered material<br />

7. Common available sizes<br />

8. Common available thicknesses/R-values<br />

9. Manufacturing plant location(s)<br />

10. UL “P” design numbers<br />

11. Code acceptance<br />

12. Limitations and/or restrictions<br />

13. See appendix<br />

Users of the guide who are interested in additional<br />

information regarding composite insulation board are<br />

encouraged <strong>to</strong> refer <strong>to</strong> The NRCA <strong>Roof</strong>ing and<br />

Waterproofing Manual, Fifth Edition<br />

Expanded Polystyrene<br />

Expanded polystyrene (EPS) insulation board is<br />

formed with a polystyrene polymer. The polymer is<br />

impregnated with a foaming agent which, when<br />

exposed <strong>to</strong> heat, creates an expanded, relatively<br />

uniform, closed-cell material that is resistant <strong>to</strong> heat<br />

flow and moisture penetration.<br />

EPS is available in several different densities, several<br />

board sizes and a number of board thicknesses. EPS<br />

is also available in tapered thickness boards.<br />

The material standard that applies <strong>to</strong> EPS is American<br />

Society for Testing and Materials (ASTM) C578, titled<br />

“Standard Specification for Preformed, Cellular<br />

Polystyrene Thermal Insulation.”<br />

419


Information on Section 2: Rigid Board Insulation<br />

Information on EPS is presented in the guide in the<br />

Expanded Polystyrene <strong>Roof</strong> Insulation Board section.<br />

Specific information included is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Complies with (applicable ASTM standard)<br />

4. Physical properties<br />

5. Surface treatment<br />

6. Available as tapered material<br />

7. Common available sizes<br />

8. Common available thicknesses/R-values<br />

9. Manufacturing plant location(s)<br />

10. UL “P” design numbers<br />

11. Code acceptance<br />

12. Limitations and/or restrictions<br />

13. See appendix<br />

Users of the guide who are interested in additional<br />

information regarding EPS are encouraged <strong>to</strong> refer <strong>to</strong><br />

The NRCA <strong>Roof</strong>ing and Waterproofing Manual, Information on glass fiber board roof insulation is<br />

Fourth Edition.<br />

Extruded Polystyrene<br />

Extruded polystyrene (XPS) insulation board is formed<br />

with a polystyrene polymer. The blended polystyrene<br />

polymer is heated, put through an extrusion process<br />

and then exposed <strong>to</strong> normal atmospheric conditions<br />

so the material will expand. Closed cells are formed<br />

within the material during this expansion process.<br />

The extrusion process provides smooth, skin-like<br />

surfaces on the material.<br />

XPS is available in several different densities, several<br />

different board sizes and a number of board<br />

thicknesses.<br />

The material standard that applies <strong>to</strong> XPS is American<br />

Society for Testing and Materials (ASTM) C578, titled<br />

“Standard Specification for Preformed, Cellular<br />

Polystyrene Thermal Insulation.”<br />

Users of the guide who are interested in additional<br />

information regarding XPS are encouraged <strong>to</strong> refer <strong>to</strong><br />

The NRCA <strong>Roof</strong>ing and Waterproofing Manual, Fifth<br />

Edition.<br />

Glass Fiber<br />

Glass fiber board roof insulation is a rigid board<br />

insulating material manufactured from bonded glass<br />

fiber wool with an adhered kraft paper face on the <strong>to</strong>p<br />

surface.<br />

Glass fiber board roof insulation is available in<br />

several board sizes and a number of board<br />

thicknesses.<br />

The material standard that applies <strong>to</strong> glass fiber<br />

board insulation is American Society for Testing and<br />

Materials (ASTM) C726, titled “Standard Specification<br />

for Mineral Fiber <strong>Roof</strong> Insulation Board.”<br />

presented in the guide in the Glass Fiber <strong>Roof</strong><br />

Insulation Board section. Specific listing information<br />

included is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Complies with (applicable ASTM standard)<br />

4. Physical properties<br />

5. Surface treatment<br />

6. Available as tapered material<br />

7. Common available sizes<br />

8. Common available thicknesses/R-values<br />

9. Manufacturing plant location(s)<br />

10. UL “P” design numbers<br />

11. Code acceptance<br />

12. Limitations and/or restrictions<br />

13. See appendix<br />

Users of the guide who are interested in additional<br />

information regarding glass fiber board roof insulation<br />

are encouraged <strong>to</strong> refer <strong>to</strong> The NRCA <strong>Roof</strong>ing and<br />

Waterproofing Manual, Fifth Edition.<br />

Information on XPS is presented in the guide in the<br />

Extruded Polystyrene <strong>Roof</strong> Insulation Board section.<br />

Specific listing information included is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Complies with (applicable ASTM standard)<br />

4. Physical properties<br />

5. Surface treatment<br />

6. Available as tapered material<br />

7. Common available sizes<br />

8. Common available thicknesses/R-values<br />

9. Manufacturing plant location(s)<br />

10. UL “P” design numbers<br />

11. Code acceptance<br />

12. Limitations and/or restrictions<br />

13. See appendix<br />

Glass Mat-faced Gypsum Board<br />

Glass mat-faced gypsum board roof insulation is a<br />

rigid insulating material manufactured with a gypsum<br />

core and glass mat facers on the board’s <strong>to</strong>p and<br />

bot<strong>to</strong>m sides.<br />

Glass mat-faced gypsum board roof insulation is<br />

available in several different board sizes and<br />

thicknesses.<br />

The material standard that applies <strong>to</strong> glass mat-faced<br />

gypsum board roof insulation is American Society for<br />

testing and Materials (ASTM ) C1177, titled “Standard<br />

Specification for Glass Mat Gypsum Substrate for Use<br />

as Sheathing.”<br />

420


Information on Section 2: Rigid Board Insulation<br />

Information on glass mat-faced gypsum board roof<br />

insulation is presented in the guide in the Glass Matfaced<br />

Gypsum Board section. Specific listing<br />

information included is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Complies with (applicable ASTM standard)<br />

4. Physical properties<br />

5. Surface treatment<br />

6. Available as tapered material<br />

7. Common available sizes<br />

8. Common available thicknesses/R-values<br />

9. Manufacturing plant location(s)<br />

10. UL “P” design numbers<br />

11. Code acceptance<br />

12. Limitations and/or restrictions<br />

13. See appendix<br />

Users of the guide who are interested in additional<br />

information regarding glass mat-faced gypsum board<br />

roof insulation are encouraged <strong>to</strong> refer <strong>to</strong> The NRCA<br />

<strong>Roof</strong>ing and Waterproofing Manual, Fifth Edition.<br />

Perlite<br />

Perlite board roof insulation is a rigid insulating<br />

material manufactured from expanded volcanic<br />

materials combined with organic fibers and binders.<br />

The <strong>to</strong>p surface of perlite roof insulation generally is<br />

treated with an asphalt emulsion <strong>to</strong> minimize bitumen<br />

absorption.<br />

Perlite insulation board is available in several different<br />

board sizes and a number of board thicknesses. It is<br />

also available in tapered thickness boards.<br />

The material standard that applies <strong>to</strong> the perlite<br />

insulation board is American Society for Testing and<br />

Materials (ASTM) C728, titled “Standard Specification<br />

for Perlite Thermal Insulation Board.”<br />

Information on perlite insulation board is presented in<br />

the guide in the Perlite <strong>Roof</strong> Insulation Board section.<br />

Specific listing information included is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Complies with (applicable ASTM standard)<br />

4. Physical properties<br />

5. Surface treatment<br />

6. Available as tapered material<br />

7. Common available sizes<br />

8. Common available thicknesses/R-values<br />

9. Manufacturing plant location(s)<br />

10. UL “P” design numbers<br />

11. Code acceptance<br />

12. Limitations and/or restrictions<br />

13. See appendix<br />

Users of the guide who are interested in additional<br />

information regarding perlite insulation board are<br />

encouraged <strong>to</strong> refer <strong>to</strong> The NRCA <strong>Roof</strong>ing and<br />

Waterproofing Manual, Fifth Edition.<br />

Polyisocyanurate<br />

Polyisocyanurate foam roof insulation board is<br />

manufactured as a closed cell rigid foam insulation.<br />

For rigid roof insulation, the polyisocyanurate foam<br />

material is typically sandwiched between asphaltsaturated<br />

organic or inorganic felt facers or inorganic<br />

glass fiber mat facers.<br />

Polyisocyanurate roof insulation is available in several<br />

different board sizes and a number of board<br />

thicknesses. It is also available in tapered thickness<br />

boards.<br />

The material standard that applies <strong>to</strong><br />

polyisocyanurate insulation board is American Society<br />

for Testing and Materials (ASTM) C1289, titled<br />

“Standard Specification for Faced Rigid<br />

Polyisocyanurate Thermal Insulation Board.”<br />

Information on polyisocyanurate insulation board is<br />

presented in the guide in the Polyisocyanurate <strong>Roof</strong><br />

Insulation Board section in two parts: part 1: General<br />

Information and Part 2: Test Results.<br />

Specific listing information included in Part 1: General<br />

Information is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Complies with (applicable ASTM standard)<br />

4. Physical properties<br />

5. Surface treatment<br />

6. Available as tapered material<br />

7. Common available sizes<br />

8. Common available thicknesses/R-values<br />

9. Manufacturing plant location(s)<br />

10. UL “P” design numbers<br />

11. Code acceptance<br />

12. Limitations and/or restrictions<br />

13. See appendix<br />

Users of the guide who are interested in additional<br />

information regarding polyisocyanurate insulation<br />

board are encouraged <strong>to</strong> refer <strong>to</strong> The NRCA <strong>Roof</strong>ing<br />

and Waterproofing Manual, Fifth Edition<br />

Wood Fiberboard<br />

Wood fiberboard roof insulation is a rigid insulating<br />

material manufactured from wood or cane fibers and<br />

various binders.<br />

Wood fiberboard insulation board is available in<br />

several densities, several different board sizes and a<br />

number of board thicknesses.<br />

421


Information on Section 2: Rigid Board Insulation<br />

The material standard that applies <strong>to</strong> the wood<br />

fiberboard roof insulation is American Society for<br />

Testing and Materials (ASTM) C208, titled “Standard<br />

Specification for Cellulosic Fiber Insulating Board.”<br />

Information on wood fiberboard insulation board is<br />

presented in the guide in the Wood Fiberboard <strong>Roof</strong><br />

Insulation Board section. Specific listing information<br />

included is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Complies with (applicable ASTM standard)<br />

4. Physical properties<br />

5. Surface treatment<br />

6. Available as tapered material<br />

7. Common available sizes<br />

8. Common available thicknesses/R-values<br />

9. Manufacturing plant location(s)<br />

10. UL “P” design numbers<br />

11. Code acceptance<br />

12. Limitations and/or restrictions<br />

13. See appendix<br />

Users of the guide who are interested in additional<br />

information regarding wood fiberboard insulation are<br />

encouraged <strong>to</strong> refer <strong>to</strong> The NRCA <strong>Roof</strong>ing and<br />

Waterproofing Manual, Fifth Edition.<br />

422


Index <strong>to</strong> Rigid Board Insulation<br />

WOOD FIBERBOARD<br />

POLYISOCYANURATE<br />

PERLITE<br />

GLASS-MAT FACED GYPSUM<br />

GLASS FIBER<br />

EXTRUDED POLYSTYRENE<br />

EXPANDED POLYSTYRENE<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

WOOD FIBERBOARD<br />

POLYISOCYANURATE<br />

PERLITE<br />

GLASS-MAT FACED GYPSUM<br />

GLASS FIBER<br />

EXTRUDED POLYSTYRENE<br />

EXPANDED POLYSTYRENE<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

A F M R-CONTROL BUILDING SYSTEMS 426 432 G-P GYPSUM CORPORATION 456<br />

2400 W. Highway 7, Suite 201 133 Peachtree St. NE<br />

Excelsior, MN 55331 Atlanta, GA 30303<br />

800/255-0176 800/225-6119<br />

FAX: 952/474-2074 FAX: 404/230-7052<br />

E-mail: afm@r-control.com<br />

E-mail:<br />

Web Site: www.r-control.com<br />

Web:<br />

ARVRON INC. 433 HUEBERT FIBERBOARD CO. 471<br />

4720 Clay S.W. 1545 E Morgan Street, Box 167<br />

Grand Rapids, MI 49548 Boonville, MO 65233<br />

616/530-1888 660/882-2704<br />

FAX: FAX 660/882-2704<br />

E-mail:<br />

E-mail:<br />

Web:<br />

Web: www.huebertfiberboard.com<br />

ATLAS ROOFING CORPORATION 460 INSUL-BOARD, INC. 438<br />

1775 The Exchange, Suite 160 2120 Colonial Avenue<br />

Atlanta, GA 30339 P.O. Box 8103<br />

770/933-4478 Erie, PA 16505<br />

FAX 770/952-3170 814/833-7400<br />

E-mail: FAX 814/838-4774<br />

Web: www.atlasroofing.com<br />

E-mail: insul@erie.net<br />

BENCHMARK FOAM INC. 427 434 INSULATED BUILDING SYSTEMS, INC. 428 438<br />

3200 9th Ave., S.E. 9912 George<strong>to</strong>wn Pike, Suite D2<br />

Water<strong>to</strong>wn, SD 57201-9102 Great Falls, VA 22066<br />

800/658-3444 703/757-0118<br />

FAX 605/886-8099 FAX 703/757-0119<br />

E-mail: getfoam@benchmarkfoam.com<br />

E-mail: nicos@rcontrollbs.com<br />

Web: www.benchmarkfoam.com<br />

Web:<br />

BIG SKY INULATIONS INC. 435 JOHNS MANVILLE INTERNATIONAL INC. 429 454 459 465<br />

15 Arden Drive <strong>Roof</strong>ing Systems Group<br />

P.O. Box 838 P.O. Box 5108<br />

Belgrade, MT 59714 Denver, CO 80217<br />

406/388-4146 303/978-2000<br />

FAX: FAX 303/978-3904<br />

Web:<br />

E-mail:<br />

CARLISLE SYNTEC INCORPORATED 436 442 463 470 KOPPERS INDUSTRIES INC. 429 459 466 471<br />

P.O. Box 7000<br />

Commercial <strong>Roof</strong>ing Dept.<br />

Carlisle, PA 17013<br />

436 Seventh Avenue<br />

717/245-7000 Pittsburgh, PA 15219-1800<br />

FAX: 800/468-9629<br />

E-mail: FAX: 412/227-2002<br />

Web: www.carlislesyntec.com<br />

Web: www.koppers.com<br />

DOW CHEMICAL COMPANY, THE 445 OWENS CORNING 448<br />

Fabricated Products Business Center<br />

275 Southwest Avenue<br />

1605 Joseph Drive, Larkin 200 Building Tallmadge, OH 44278<br />

Midland, MI 48674 330/633-6735<br />

517/638-5225 FAX:<br />

FAX:<br />

E-mail:<br />

Web:<br />

Web:<br />

FALCON FOAM<br />

436 PACEMAKER PLASTICS CO., INC.<br />

Division Atlas <strong>Roof</strong>ing Corp. 126 New Pace Road., P.O. Box 279<br />

8240 Byron Center Road Newcomers<strong>to</strong>wn, OH 43832<br />

Byron Center, MI 49315 800/446-2188<br />

616/878-1568 FAX 740/498-4184<br />

FAX: 616/878-9942<br />

E-mail: pacemaker@tusco.net<br />

E-mail:<br />

Web: www.pacemakerplastics.com<br />

429 439<br />

FIRESTONE BUILDING PRODUCTS, INC. 427 456 464 470 PACTIV BUILDING PRODUCTS 453<br />

525 Congressional Blvd. 2100 RiverEdge Parkway, Suite 175<br />

Carmel, IN 46032-5607 Atlanta, GA 30328<br />

800/428-4442 800/241-4402<br />

FAX: 317/575-7100<br />

FAX:<br />

E-mail: fires<strong>to</strong>nebp.com<br />

E-mail:<br />

Web:<br />

Web: www.pactivbuildingproducts.com<br />

GAF MATERIALS CORP. 437 447 458 465 471 PITTSBURGH CORNING CORP. 425<br />

1361 Alps Road 800 Presque Isle Drive<br />

Wayne, NJ 07470 Pittsburg, PA 15239<br />

973/628-3000 800/359-8433<br />

FAX 973/628-3356 FAX: 724/327-5890<br />

E-mail:<br />

E-mail:<br />

Web:<br />

Web: www.foamglasinsulation.com<br />

423


Index <strong>to</strong> Rigid Board Insulation<br />

WOOD FIBERBOARD<br />

POLYISOCYANURATE<br />

PERLITE<br />

GLASS-MAT FACED GYPSUM<br />

GLASS FIBER<br />

EXTRUDED POLYSTYRENE<br />

EXPANDED POLYSTYRENE<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

WOOD FIBERBOARD<br />

POLYISOCYANURATE<br />

PERLITE<br />

GLASS-MAT FACED GYPSUM<br />

GLASS FIBER<br />

EXTRUDED POLYSTYRENE<br />

EXPANDED POLYSTYRENE<br />

COMPOSITE INSULATION<br />

CELLULAR GLASS INSULATION<br />

PLYMOUTH FOAM INCORPORATED 441 TEMPLE 472<br />

1800 Sunset Drive P.O. Drawer N<br />

Plymouth, WI 53073 Diboll, TX 75941<br />

920/893-0535 936/829-1254 800/231-6060<br />

FAX 920/892-4986 FAX: 800/426-7382<br />

E-maiol:<br />

Web: www.plymouthfoam.com<br />

E-mail: gkeeling@temple.com<br />

Web: www.temple.com<br />

POLY FOAM INC. 441 TREMCO INC. 467 473<br />

116 Pine Street South 3735 Green Road<br />

Lester Prairie, MN 55354-0218 Beachwood, OH 44122<br />

320/395-2551 216/292-5000<br />

FAX: FAX: 216/292-5077<br />

E-mail:<br />

E-mail: tremcoroofing.com<br />

Web:<br />

Web:<br />

R-MAX INC. 430 467 U.S. INTEC, INC. 468<br />

13524 Welch Road 1361 Alps Road<br />

Dallas, TX 75244 Wayne,NJ 07470<br />

972/387-4500 800/624-6832<br />

FAX: 972/387-4673 FAX: 973/628-4167<br />

E-mail:<br />

E-mail:<br />

Web: www.rminc.com<br />

Web: www.usintec.com<br />

T-CLEAR CORPORATION 430<br />

P. O. Box 416<br />

Hamil<strong>to</strong>n, OH 45012<br />

800/ 544-7398 or 513/870-9243<br />

FAX 513/870-9606<br />

E-mail: telesouth1.com<br />

Web:<br />

424


Cellular Glass <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME PITTSBURGH<br />

CORNING<br />

CORPORATION<br />

2. PRODUCT NAME FOAMGLAS<br />

INSULATION<br />

3. COMPLIES WITH:<br />

ASTM C 552-91 Standard Specification for Cellular Glass Thermal Insulation<br />

(indicate Type IV or other types, if appropriate)<br />

4. PHYSICAL PROPERTIES (per ASTM C552-91):<br />

Density, min., lbs/ft³ 6.7 6.8<br />

Density, max., lbs/ft³ 9.2 9.7<br />

Compressive strength, min., psi 65 6.0<br />

Flexural strength, min., psi 60 6.0<br />

Water absorption, max., volume % 0.5 0.5<br />

5. SURFACE TREATMENT:<br />

Top Surface<br />

KRAFT SHEET<br />

UNFACED<br />

Bot<strong>to</strong>m Surface<br />

KRAFT SHEET<br />

UNFACED<br />

6. AVAILABLE AS TAPERED MATERIAL (yes/no) YES<br />

7. COMMON AVAILABLE SIZES:<br />

2' X 4' X<br />

3' X 4'<br />

4' X 4'<br />

4' X 8'<br />

Other (describe) 18" X 24"<br />

8. COMMON AVAILABLE THICKNESSES/R-VALUES (indicate thickness,<br />

R-value for thickness at 40º F and R-value at 75º F) 1.5 4.98 4.69<br />

2 6.65 6.25<br />

2.5 8.31 7.81<br />

3 9.97 9.37<br />

3.5 11.63 10.94<br />

4 13.29 12.50<br />

4.5 14.95 14.06<br />

5 16.61 15.62<br />

9. MANUFACTURING PLANT LOCATION(S) SEDALIA, MO<br />

PT. ALLEGANY, PA<br />

10. UL "P" DESIGN NUMBERS (indicate P-design numbers) 227, 508, 701,<br />

801, 819<br />

11. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number)<br />

ICBO Evaluation Service, Inc. (indicate report number)<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number)<br />

BOCA Evaluation Service, Inc. (indicate report number)<br />

Other (indicate report number)<br />

12. LIMITATIONS AND/OR RESTRICTIONS<br />

13. SEE APPENDIX IF CHECKED<br />

NYCMCA 138 81M<br />

BSA 131-44 SM<br />

425


Composite <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME AFM AFM<br />

R-CONTROL R-CONTROL<br />

2. PRODUCT NAME R-CONTROL R-CONTROL<br />

SIP<br />

SPEC LAM<br />

4. COMPLIES WITH (indicate applicable standard[s]):<br />

ASTM C-578, TYPE II<br />

DOC PS2-92<br />

ASTM C-578 TYPE I<br />

DOC PS2-92<br />

5. PHYSICAL PROPERTIES:<br />

Compressive strength, min., psi<br />

Dimensional stability, % linear change, max.<br />

Flexural strength, min., psi<br />

Tensile strength (perpendicular <strong>to</strong> board surface) min., psi<br />

Water absorption, max., volume %<br />

6. SURFACE TREATMENT:<br />

Top Surface OSB OSB<br />

Bot<strong>to</strong>m Surface OSB OSB<br />

7. AVAILABLE AS TAPERED MATERIAL (yes/no) NO YES<br />

8. COMMON AVAILABLE SIZES:<br />

2' X 4'<br />

3' X 4'<br />

4' X 4' X<br />

4' X 8' X X<br />

Other (describe) UP TO 8' X 24'<br />

9. COMMON AVAILABLE THICKNESSES/R-VALUES<br />

(indicate thickness, R-value for thickness at 40º F and R-value at 75º F) 4.5 IN - 16.0 / 14.9 2 IN - 6.8 / 6.4<br />

6.5 IN - 24.2 / 22.6 4 IN - 15.2 / 14.1<br />

8.25 IN - 31.6 / 29.3 6 IN - 23.5 / 21.8<br />

10.25 IN - 39.9 / 37.0 7.75 IN - 30.8 / 28.5<br />

12.25 IN - 48.3 / 44.7 9.75 IN - 39.1 / 36.2<br />

11.75 IN - 47.5 / 43.9<br />

10. MANUFACTURING PLANT LOCATION(S) SEE APPENDIX SEE APPENDIX<br />

11. UL "P" DESIGN NUMBERS (indicate P-design numbers) 517, 822<br />

12. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number) SEE NES SEE NES<br />

ICBO Evaluation Service, Inc. (indicate report number) PFC-4457 ER-4169<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number) NER-551 NER-551<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number) 94136C 94136C<br />

Other agencies (indicate agency & report identification number) SEE APPENDIX SEE APPENDIX<br />

13. LIMITATIONS AND/OR RESTRICTIONS<br />

14. SEE APPENDIX IF CHECKED X X<br />

426


Composite <strong>Roof</strong> Insulation Board<br />

BENCHMARK BIG SKY BIG SKY FIRESTONE FIRESTONE<br />

FOAM INC. INSULATIONS, INSULATIONS, BUILDING BUILDING<br />

INC. INC. PRODUCTS PRODUCTS<br />

PERMA FOAM R-CONTROL R-CONTROL IS0 95+ ISO 95+<br />

EPS FIBERBOARD SIP SPEC-LAM COMPOSITE COMPOSITE<br />

COMPOSITE<br />

ASTM C 208 ASTM C-578, TYPE I ASTM C-578, TYPE I ASTM C- 1289, ASTM C-1289,<br />

ASTM C 578 PS2-92 PS9-92 TYPE III TYPE IV<br />

10 20 20<br />

2 2 2<br />

40 40<br />

10 500 500<br />

3.7 1 2<br />

OSB OSB PERLITE FIBERBOARD<br />

OSB OSB GLASS GLASS<br />

REINFORCED REINFORCED<br />

ORGANIC MAT ORGANIC MAT<br />

YES NO YES YES<br />

X<br />

X X X X<br />

X X X X X<br />

4' X 12' ; 4' X 16' UP TO 8' X 24'<br />

2 IN - 7.2 / 6.7 4.5 IN - 16.0 / 14.9 2 IN - 6.8 / 6.4 1.5 IN - 7.4 1.5 IN - 7.4<br />

6.5 IN - 24.2 / 22.6 4 IN - 15.2 / 14.1 2.0 IN - 11.4 2.0 IN - 11.4<br />

8.25 IN - 31.6 / 29.3 6 IN - 23.5 / 21.8 2.5 IN - 15.7 2.5 IN - 15.7<br />

10.25 IN - 39.9 / 37.07 7.75 IN - 30.8 / 28.5 3.0 IN - 20 3.0 IN - 20<br />

12.25 IN - 48.3 / 44.79 9.75 IN - 39.1 / 36.2 3.5 IN - 23.4 3.5 IN - 23.4<br />

11.75 IN - 47.5 / 43.9 4.0 IN - 27.2 4.0 IN - 27.2<br />

WATERTOWN, SD SEE APPENDIX SEE APPENDIX COLORADO COLORADO<br />

CONNECTICUT CONNECTICUT<br />

FLORIDA<br />

FLORIDA<br />

KENTUCKY<br />

KENTUCKY<br />

PENNSYLVANIA PENNSYLVANIA<br />

UTAH, WISCONSIN UTAH, WISCONSIN<br />

517 SEE APPENDIX SEE APPENDIX<br />

822<br />

SEE NES<br />

SEE NES<br />

PFC-4457<br />

ER-4169<br />

NER-551<br />

NER-551<br />

94136C 94136C 9595<br />

SEE APPENDIX SEE APPENDIX<br />

X X X X<br />

427


Composite <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME FIRESTONE INSULATED<br />

BUILDING<br />

BUILDING<br />

PRODUCTS SYSTEMS, INC.<br />

2. PRODUCT NAME NAILBASE R-CONTROL<br />

PERFORM 2 & 3<br />

4. COMPLIES WITH (indicate applicable standard[s]):<br />

ASTM C-1289,<br />

TYPE V<br />

ASTM C-578,<br />

TYPE I<br />

5. PHYSICAL PROPERTIES:<br />

Compressive strength, min., psi 20 10-25<br />

Dimensional stability, % linear change, max. 2<br />

Flexural strength, min., psi 40 25-50<br />

Tensile strength (perpendicular <strong>to</strong> board surface) min., psi 500<br />

Water absorption, max., volume % 1 4-2<br />

6. SURFACE TREATMENT:<br />

Top Surface OSB OSB, FIBERBOARD,<br />

GYSUM, PERLITE,<br />

OR ISO<br />

Bot<strong>to</strong>m Surface GLASS OSB, FIBERBOARD,<br />

REINFORCED GYSUM, PERLITE,<br />

ORGANIC MAT<br />

OR ISO<br />

7. AVAILABLE AS TAPERED MATERIAL (yes/no) NO YES<br />

8. COMMON AVAILABLE SIZES:<br />

2' X 4' X<br />

3' X 4' X<br />

4' X 4' X X<br />

4' X 8' X X<br />

Other (describe) 4' X 16'<br />

9. COMMON AVAILABLE THICKNESSES/R-VALUES<br />

(indicate thickness, R-value for thickness at 40º F and R-value at 75º F) 1.5 IN - 6.9 FROM 1" TO 36"<br />

2.0 IN - 11.4 1" TYPE I - 1.0 LB<br />

2.5 IN - 15.4 4.0 / 3.6<br />

3.0 IN - 19.4<br />

3.5 IN - 23 1" TYPE XI - 2.0 LB<br />

4.0 IN - 26.8 4.6 / 4.2<br />

10. MANUFACTURING PLANT LOCATION(S) COLORADO WINCHESTER, VA<br />

CONNECTICUT<br />

FLORIDA<br />

KENTUCKY<br />

PENNSYLVANIA<br />

UTAH, WISCONSIN<br />

11. UL "P" DESIGN NUMBERS (indicate P-design numbers) SEE APPENDIX<br />

12. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number)<br />

ICBO Evaluation Service, Inc. (indicate report number)<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number)<br />

Other agencies (indicate agency & report identification number)<br />

ER-4169<br />

NER-551<br />

94136C<br />

13. LIMITATIONS AND/OR RESTRICTIONS<br />

14. SEE APPENDIX IF CHECKED X X<br />

428


Composite <strong>Roof</strong> Insulation Board<br />

JOHNS JOHNS KOPPERS PACEMAKER PACEMAKER<br />

MANVILLE MANVILLE INDUSTRIES, PLASTICS PLASTICS<br />

INTERNATIONAL INTERNATIONAL INC.<br />

FESCO BOARD NAILBOARD KOP-R R-CONTROL R-CONTROL<br />

COMPOSITE SIP SPEC LAM<br />

ASTM C-1289, ASTM C-1289, ASTM C-578, ASTM C-578,<br />

TYPE III TYPE V TYPE I TYPE I<br />

PS 2-92 PS 2-92<br />

20 20 20<br />

500 >500<br />

1.5 1.5


Composite <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME R MAX, INC. T-CLEAR<br />

CORPORATION<br />

2. PRODUCT NAME THERMAROOF LIGHTGUARD<br />

COMPOSITE<br />

4. COMPLIES WITH (indicate applicable standard[s]):<br />

ASTM C-1289,<br />

TYPE III<br />

ASTM C-578-95,<br />

TYPE VI<br />

5. PHYSICAL PROPERTIES:<br />

Compressive strength, min., psi 16 40<br />

Dimensional stability, % linear change, max. 40 60<br />

Tensile strength (perpendicular <strong>to</strong> board surface) min., psi >500 >35<br />

Water absorption, max., volume % 1.0 0.3<br />

6. SURFACE TREATMENT:<br />

Top Surface PERLITE 3/8" CONCRETE<br />

INSULATION<br />

BOARD<br />

Bot<strong>to</strong>m Surface<br />

ORANIC FILLED<br />

GLASS FIBER<br />

MAT<br />

7. AVAILABLE AS TAPERED MATERIAL (yes/no) NO NO<br />

8. COMMON AVAILABLE SIZES:<br />

2' X 4' X<br />

3' X 4'<br />

4' X 4' X<br />

4' X 8' X<br />

Other (describe)<br />

9. COMMON AVAILABLE THICKNESSES/R-VALUES<br />

(indicate thickness, R-value for thickness at 40º F and R-value at 75º F) 1.5 IN - NA / 7.7 2 IN - 10.8 / 10.0<br />

2.0 IN - NA / 11.1 3 IN - 16.2 / 15.0<br />

2.5 IN - NA / 15.4<br />

3.2 IN - NA / 21.4<br />

10. MANUFACTURING PLANT LOCATION(S) DALLAS, TX HAMILTON, OH<br />

FERNLEY, NV<br />

GREEN, SC<br />

11. UL "P" DESIGN NUMBERS (indicate P-design numbers) 225, 230, 259, 510, 701, 713, 225, 229, 230,<br />

718, 719, 720, 722, 723, 724 235, 404, 505,<br />

725, 727, 728, 729, 730, 732, 507, 714, 803<br />

801, 814, 817, 818, 819, 823,828 904<br />

12. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number)<br />

ICBO Evaluation Service, Inc. (indicate report number)<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number)<br />

Other agencies (indicate agency & report identification number)<br />

LOS ANGELES<br />

RR # 25378<br />

13. LIMITATIONS AND/OR RESTRICTIONS PMR INSULATION<br />

14. SEE APPENDIX IF CHECKED X<br />

430


Composite <strong>Roof</strong> Insulation Board<br />

T-CLEAR<br />

CORPORATION<br />

HEAVYGUARD<br />

ASTM C-578-95,<br />

TYPE VI<br />

40<br />

2.0<br />

60<br />

>35<br />

0.3<br />

15/16" CONCRETE<br />

NO<br />

X<br />

2 IN - 10.8 / 10.0<br />

3 IN - 16.2 / 15.0<br />

HAMILTON, OH<br />

225, 229, 230,<br />

235, 404, 505,<br />

507, 714, 803<br />

904<br />

PMR INSULATION<br />

431


Expanded Polystyrene <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME AFM R-CONTROL AFM R-CONTROL<br />

2. PRODUCT NAME PERFORM PERFORM<br />

CONTOUR TAPER CONTROUR TAPER<br />

TILE<br />

TILE<br />

3. NOMINAL DENSITY (lbs/ft³) 1.00 1.25<br />

4. COMPLIES WITH:<br />

ASTM C 578-95 Standard Specification for Rigid, Cellular Polystyrene<br />

Thermal Insulation (indicate Type I, II, VIII, IX or XI)<br />

TYPE I<br />

TYPE VIII<br />

5. PHYSICAL PROPERTIES (per ASTM D 578-95):<br />

Density, min., lbs/ft³ 0.9 1.15<br />

Compressive strength, min., psi 10 13<br />

Flexural strength, min., psi 25 30<br />

Water vapor permeance of 1.0 inch thickness, max., perm. 5.0 3.5<br />

Water absorption, max., volume % 4.0 3.0<br />

6. SURFACE TREATMENT:<br />

Top Surface<br />

OPTIONAL: ROOFING FELT OPTIONAL: ROOFING FELT<br />

Bot<strong>to</strong>m Surface<br />

FACED, FOILD FACED, KRAFT FACED, FOILD FACED, KRAFT<br />

FACED, PERFORM PROTECDT FACED, PERFORM PROTECDT<br />

7. AVAILABLE AS TAPERED MATERIAL (yes/no) YES YES<br />

8. COMMON AVAILABLE SIZES:<br />

2' X 4' X X<br />

3' X 4' X X<br />

4' X 4' X X<br />

4' X 8' X X<br />

Other (describe)<br />

9. COMMON AVAILABLE THICKNESSES/R-VALUES (indicate<br />

thickness, R-value for thickness at 40º F and R-value at 75º F) 1 IN - 4.00 / 3.60 1 IN - 4.20 / 3.80<br />

10. MANUFACTURING PLANT LOCATION(S) SEE APPENDIX SEE APPENDIX<br />

11. UL "P" DESIGN NUMBERS (indicate P-design number) SEE APPENDIX SEE APPENDIX<br />

12. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number) See NEX See NES<br />

ICBO Evaluation Service, Inc. (indicate report number) ER-4169 ER-4169<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number) NER-551 NER-551<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number) 94136C 94136C<br />

Other agencies (indicate agency & report identification number) SEE APPENDIX SEE APPENDIX<br />

13. LIMITATIONS AND/OR RESTRICTIONS<br />

14. SEE APPENDIX IF CHECKED X X<br />

432


Expanded Polystyrene <strong>Roof</strong> Insulation Board<br />

AFM R-CONTROL AFM R-CONTROL ARVRON, INC. BENCHMARK BENCHMARK<br />

FOAM, INC.<br />

FOAM, INC.<br />

PERFORM PERFORM STEER-O-CELL PERMA-FORM PERMA-FOAM<br />

CONTROUR TAPER CONTROUR TAPER<br />

TILE<br />

TILE<br />

1.50 2.00 1.00 1.00 1.50<br />

TYPE II TYPE IX TYPE I TYPE I TYPE II<br />

1.35 1.80 0.90 0.90 1.35<br />

15 25 10 - 14 10 15<br />

40 50 25 - 30 25 40<br />

3.5 2.0 2.0 - 5.0 5.0 3.5<br />

3.0 2.0


Expanded Polystyrene <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME BENCHMARK BENCHMARK<br />

FOAM, INC.<br />

FOAM, INC.<br />

2. PRODUCT NAME PERMA-FOAM PERMA-FOAM<br />

3. NOMINAL DENSITY (lbs/ft³) 1.25 2<br />

4. COMPLIES WITH:<br />

ASTM C 578-95 Standard Specification for Rigid, Cellular Polystyrene<br />

Thermal Insulation (indicate Type I, II, VIII, IX or XI)<br />

TYPE VIII<br />

TYPE IX<br />

5. PHYSICAL PROPERTIES (per ASTM D 578-95):<br />

Density, min., lbs/ft³ 1.15 1.80<br />

Compressive strength, min., psi 13.0 25.0<br />

Flexural strength, min., psi 30.0 50.0<br />

Water vapor permeance of 1.0 inch thickness, max., perm. 3.5 2.0<br />

Water absorption, max., volume % 3.0 2.0<br />

6. SURFACE TREATMENT:<br />

Top Surface NA NA<br />

Bot<strong>to</strong>m Surface NA NA<br />

7. AVAILABLE AS TAPERED MATERIAL (yes/no) YES YES<br />

8. COMMON AVAILABLE SIZES:<br />

2' X 4' X X<br />

3' X 4' X X<br />

4' X 4' X X<br />

4' X 8' X X<br />

Other (describe) CUSTOM CUSTOM<br />

9. COMMON AVAILABLE THICKNESSES/R-VALUES (indicate<br />

thickness, R-value for thickness at 40º F and R-value at 75º F) 1 IN - 4.20 / 3.80 1 IN - 4.60 / 4.20<br />

2 IN - 8.40 / 7.60 2 IN - 9.20 / 8.40<br />

3 IN - 12.60 / 11.40 3 IN - 13.80 / 12.60<br />

4 IN - 16.80 / 15.20 4 IN - 18.40 / 16.80<br />

6 IN - 25.20 / 22.80 6 IN - 27.60 / 25.20<br />

8 IN - 33.60 / 30.40 8 IN - 36.80 / 33.60<br />

10 IN - 42.00 / 38.00 10 IN - 46.00 / 42.00<br />

10. MANUFACTURING PLANT LOCATION(S) WATERTOWN SD WATERTOWN SD<br />

11. UL "P" DESIGN NUMBERS (indicate P-design number) SEE APPENDIX SEE APPENDIX<br />

12. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number)<br />

ICBO Evaluation Service, Inc. (indicate report number)<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number)<br />

Other agencies (indicate agency & report identification number) SEE APPENDIX SEE APPENDIX<br />

13. LIMITATIONS AND/OR RESTRICTIONS<br />

14. SEE APPENDIX IF CHECKED X X<br />

434


Expanded Polystyrene <strong>Roof</strong> Insulation Board<br />

BENCHMARK BIG SKY BIG SKY BIG SKY BIG SKY<br />

FOAM, INC. INSULATIONS, INC. INSULATIONS, INC. INSULATIONS, INC. INSULATIONS, INC.<br />

PERMA-FOAM PERFORM PERFORM PERFORM PERFORM<br />

CONTROUR TAPER CONTROUR TAPER CONTROUR TAPER CONTROUR TAPER<br />

TILE TILE TILE TILE<br />

0.75 1.00 1.25 1.50<br />

TYPE XI TYPE I TYPE VIII TYPE II<br />

0.70 0.90 1.15 1.35<br />

5.0 10.0 13.0 15.0<br />

10.0 25.0 30.0 40.0<br />

5.0 5.0 3.5 3.5<br />

4.0 4.0 3.0 3.0<br />

NA OPTIONAL: WOOD OPTIONAL: WOOD OPTIONAL: WOOD OPTIONAL: WOOD<br />

FIBER, PERLITE, FOIL FIBER, PERLITE, FOIL FIBER, PERLITE, FOIL FIBER, PERLITE, FOIL<br />

FACED, KRAFT FACED FACED, KRAFT FACED FACED, KRAFT FACED FACED, KRAFT FACED<br />

NA<br />

YES YES YES YES YES<br />

X X X X X<br />

X X X X X<br />

X X X X X<br />

X X X X X<br />

CUSTOM<br />

1 IN - 3.30 / 3.10 1 IN - 4.00 / 3.60 1 IN - 4.20 / 3.80 1 IN - 4.40 / 4.00 1 IN - 4.60 / 4.20<br />

2 IN - 6.60 / 6.20<br />

3 IN - 9.90 / 9.30<br />

4 IN - 13.20 / 12.40<br />

6 IN - 19.80 / 18.60<br />

8 IN - 26.40 / 24.80<br />

10 IN - 33.00 / 31.00<br />

WATERTOWN SD SEE APPENDIX SEE APPENDIX SEE APPENDIX SEE APPENDIX<br />

SEE APPENDIX SEE APPENDIX SEE APPENDIX SEE APPENDIX SEE APPENDIX<br />

See NES See NES See NES See NES<br />

ER-4169 ER-4169 ER-4169 ER-4169<br />

NER-551 NER-551 NER-551 NER-551<br />

94136C 94136C 94136C 94136C<br />

SEE APPENDIX SEE APPENDIX SEE APPENDIX SEE APPENDIX SEE APPENDIX<br />

X X X X X<br />

435


Expanded Polystyrene <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME CARLISLE FALCON FOAM<br />

SYNTEC<br />

A DIVISION OF<br />

INCORPORATED ATLAS ROOFING CORP.<br />

2. PRODUCT NAME SURE-SEAL EPS FALCON FOAM<br />

3. NOMINAL DENSITY (lbs/ft³) 1.0 1.00<br />

4. COMPLIES WITH:<br />

ASTM C 578-95 Standard Specification for Rigid, Cellular Polystyrene<br />

Thermal Insulation (indicate Type I, II, VIII, IX or XI)<br />

TYPE I<br />

5. PHYSICAL PROPERTIES (per ASTM D 578-95):<br />

Density, min., lbs/ft³ 0.90 0.90<br />

Compressive strength, min., psi 10.0 10.0<br />

Flexural strength, min., psi 25.0 25.0<br />

Water vapor permeance of 1.0 inch thickness, max., perm. 5.0 5.0<br />

Water absorption, max., volume % 4.0 4.0<br />

6. SURFACE TREATMENT:<br />

Top Surface<br />

TYPE I<br />

Bot<strong>to</strong>m Surface<br />

NONE<br />

7. AVAILABLE AS TAPERED MATERIAL (yes/no) YES YES<br />

8. COMMON AVAILABLE SIZES:<br />

2' X 4' X<br />

3' X 4'<br />

4' X 4' X X<br />

4' X 8' X X<br />

Other (describe) 4' X 12'<br />

9. COMMON AVAILABLE THICKNESSES/R-VALUES (indicate<br />

thickness, R-value for thickness at 40º F and R-value at 75º F) 1 IN -4.20 / 3.60 1 IN - 4.0 / 3.85<br />

10. MANUFACTURING PLANT LOCATION(S)<br />

11. UL "P" DESIGN NUMBERS (indicate P-design number) 211, 225, 701, 801<br />

803, 814, 815, 817<br />

12. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number) 98-1<br />

ICBO Evaluation Service, Inc. (indicate report number) ER-3826, ER-5527 ICBO 4059<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

NER-570<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number)<br />

Other agencies (indicate agency & report identification number)<br />

FM J 10T0A6<br />

13. LIMITATIONS AND/OR RESTRICTIONS X<br />

14. SEE APPENDIX IF CHECKED X<br />

436


Expanded Polystyrene <strong>Roof</strong> Insulation Board<br />

FALCON FOAM FALCON FOAM FALCON FOAM GAF GAF<br />

A DIVISION OF A DIVISION OF A DIVISION OF MATERIALS MATERIALS<br />

ATLAS ROOFING CORP. ATLAS ROOFING CORP. ATLAS ROOFING CORP. CORPORATION CORPORATION<br />

FALCON FOAM FALCON FOAM FALCON FOAM EVERGUARD EPS EVERGAURD<br />

EPS - HD<br />

1.25 1.50 2.00 1.5 2.0<br />

TYPE VIII TYPE II TYPE IX TYPE II TYPE IX<br />

1.15 1.35 1.80 1.35 1.8<br />

13.0 15.0 25.0 15.0 25.0<br />

30.0 40.0 50.0 40.0 50.0<br />

3.5 3.5 2.0 3.5 2.0<br />

3.0 3.0 2.0 3.0 2.0<br />

SAW-CUT BEADS<br />

SAW-CUT BEADS<br />

SAW-CUT BEADS<br />

SAW-CUT BEADS<br />

YES YES YES YES YES<br />

X X X<br />

X X X X X<br />

X X X X X<br />

4' X 12' 4 ' X 12' 4' X 12'<br />

1 IN - 4.20 / 3.92 1 IN - 4.40 / 4.17 1 IN - 4.60 / 4.35 I.0 IN - 4.4 / 4.0 1.0 IN - 4.6 / 5.2<br />

1.5 IN - 6.6 / 6.0 1.5 IN - 6.9 / 6.3<br />

2.0 IN - 8.8 / 8.0 2.0 IN - 9.2 / 8.4<br />

2.5 IN - 11.0 / 10.0 2.5 IN - 11.5 / 10.5<br />

3.0 IN - 13.2 / 12.0 3.0 IN - 13.8 / 12.6<br />

3.5 IN - 15.4 / 14.0 3.5 IN - 16.1 / 14.7<br />

4.0 IN - 17.6 / 16.0 4.0 IN - 18.4 / 16.8<br />

211, 225, 701, 801 211, 225, 701, 801 211, 225, 701, 801 CONTACT GAF<br />

803, 814, 815, 817 803, 814, 815, 817 803, 814, 815, 817<br />

ICBO 4059 ICBO 4059 ICBO 4059<br />

437


Expanded Polystyrene <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME INSUL-BOARD INC. INSULATED<br />

BUILDING SYTEMS,<br />

INC.<br />

2. PRODUCT NAME INSUL-BOARD R CONTROL<br />

PERFORM 1<br />

3. NOMINAL DENSITY (lbs/ft³) 1.0 1.0<br />

4. COMPLIES WITH:<br />

ASTM C 578-95 Standard Specification for Rigid, Cellular Polystyrene<br />

Thermal Insulation (indicate Type I, II, VIII, IX or XI)<br />

TYPE I<br />

TYPE I<br />

5. PHYSICAL PROPERTIES (per ASTM D 578-95):<br />

Density, min., lbs/ft³ 0.90 0.90<br />

Compressive strength, min., psi 10 - 14 10<br />

Flexural strength, min., psi 25 - 30 25<br />

Water vapor permeance of 1.0 inch thickness, max., perm. 2.0 - 5.0 5<br />

Water absorption, max., volume %


Expanded Polystyrene <strong>Roof</strong> Insulation Board<br />

INSULATED INSULATED INSULATED PACEMAKER PACEMAKER<br />

BUILDING SYTEMS, BUILDING SYTEMS BUILDING SYTEMS PLASTICS PLASTICS<br />

INC. INC. INC.<br />

R CONTROL R CONTROL R CONTROL CHEMFOAM CHEMFOAM<br />

PERFORM 1 PERFORM CONTOUR PERFORM CONTOUR CONTOUR CONTOUR<br />

TAPER TILE TAPER TILE TAPER TILE TAPER TILE<br />

2.0 1.0 2.0 1.0 1.25<br />

TYPE XI TYPE I TYPE XI TYPE I TYPE VIII<br />

1.80 0.90 1.8 0.90 1.15<br />

25 10 25 10 13<br />

50 25 50 25 30<br />

2 5 2 5 3.5<br />

2 2 2 4 3<br />

OPTIONAL: FELT, FOIL, OPTIONAL: FELT, FOIL, OPTIONAL: FELT, FOIL, OPTIONAL: PERFORM OPTIONAL: PERFORM<br />

FIBERBOARD FIBERBOARD FIBERBOARD PROTECT PROTECT<br />

OPTIONAL: FELT, FOIL, OPTIONAL: FELT, FOIL, OPTIONAL: FELT, FOIL,<br />

FIBERBOARD FIBERBOARD FIBERBOARD<br />

NO YES YES YES YES<br />

X X X X X<br />

X X X X X<br />

X X X X X<br />

X X X X X<br />

4' X 16' 4' X 16' 4' X 16'<br />

1 TO 36 IN - 4.6 / 4.2 1 TO 36 IN - 4.0 / 3.6 1 TO 36 IN - 4.6 / 4.2 1 IN - 4.00 / 3.60 1IN - 4.20 / 3.60<br />

WINCHESTER, VA WINCHESTER, VA WINCHESTER, VA SEE APPENDIX SEE APPENDIX<br />

SEE AFM RCONTROL SEE AFM RCONTROL SEE AFM RCONTROL SEE APPENDIX SEE APPENDIX<br />

APPENDIX APPENDIX APPENDIX<br />

SEE NES SEE NES SEE NES SEE NES SEE NES<br />

ER-4169 ER-4169 ER-4169 ER-4169 ER-4169<br />

NER-551 NER-551 NER-551 NER-551 NER-551<br />

94136C 94136C 94136C 94136C 94136C<br />

SEE AFM RCONTROL SEE AFM RCONTROL SEE AFM RCONTROL SEE APPENDIX SEE APPENDIX<br />

APPENDIX APPENDIX APPENDIX<br />

X X X<br />

439


Expanded Polystyrene <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME PACEMAKER PACEMAKER<br />

PLASTICS<br />

PLASTICS<br />

2. PRODUCT NAME CHEMFOAM CHEMFOAM<br />

CONTOUR<br />

CONTOUR<br />

TAPER TILE<br />

TAPER TILE<br />

3. NOMINAL DENSITY (lbs/ft³) 1.50 2.00<br />

4. COMPLIES WITH:<br />

ASTM C 578-95 Standard Specification for Rigid, Cellular Polystyrene<br />

Thermal Insulation (indicate Type I, II, VIII, IX or XI)<br />

TYPE II<br />

TYPE IX<br />

5. PHYSICAL PROPERTIES (per ASTM D 578-95):<br />

Density, min., lbs/ft³ 1.35 1.80<br />

Compressive strength, min., psi 15 25<br />

Flexural strength, min., psi 40 50<br />

Water vapor permeance of 1.0 inch thickness, max., perm. 3.5 2<br />

Water absorption, max., volume % 3 2<br />

6. SURFACE TREATMENT:<br />

Top Surface OPTIONAL: PERFORM OPTIONAL: PERFORM<br />

PROTECT<br />

PROTECT<br />

Bot<strong>to</strong>m Surface<br />

7. AVAILABLE AS TAPERED MATERIAL (yes/no) YES YES<br />

8. COMMON AVAILABLE SIZES:<br />

2' X 4' X X<br />

3' X 4' X X<br />

4' X 4' X X<br />

4' X 8' X X<br />

Other (describe)<br />

9. COMMON AVAILABLE THICKNESSES/R-VALUES (indicate<br />

thickness, R-value for thickness at 40º F and R-value at 75º F) 1 IN - 4.40 / 4.00 1 IN - 4.60 / 4.20<br />

10. MANUFACTURING PLANT LOCATION(S) SEE APPENDIX SEE APPENDIX<br />

11. UL "P" DESIGN NUMBERS (indicate P-design number) SEE APPENDIX SEE APPENDIX<br />

12. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number) SEE NES SEE NES<br />

ICBO Evaluation Service, Inc. (indicate report number) ER-4169 ER-4169<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number) NER-551 NER-551<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number) 94136C 94136C<br />

Other agencies (indicate agency & report identification number) SEE APPENDIX SEE APPENDIX<br />

13. LIMITATIONS AND/OR RESTRICTIONS<br />

14. SEE APPENDIX IF CHECKED X X<br />

440


Expanded Polystyrene <strong>Roof</strong> Insulation Board<br />

PLYMOUTH PLYMOUTH PLYMOUTH PLYMOUTH POLYFOAM INC<br />

FOAM INC. FOAM INC. FOAM INC. FOAM INC.<br />

POLYTEC EPS POLYTEC EPS POLYTEC EPS POLYTEC EPS DRI-LITE<br />

1.00 1.25 1.50 2.0<br />

TYPE I TYPE VIII TYPE II TYPE IX<br />

0.90 1.15 1.35 1.80<br />

10 13 15 25<br />

25 30 40 50<br />

5.0 3.5 3.5 2.0<br />

4 3 3 2<br />

POLYMERIC FOAM POLYMERIC FOAM POLYMERIC FOAM POLYMERIC FOAM<br />

IS AVAILABLE IS AVAILABLE IS AVAILABLE IS AVAILABLE<br />

POLYMERIC FOAM POLYMERIC FOAM POLYMERIC FOAM POLYMERIC FOAM<br />

IS AVAILABLE IS AVAILABLE IS AVAILABLE IS AVAILABLE<br />

YES YES YES YES YES<br />

X X X X<br />

X X X X<br />

X X X X<br />

SADDLES SADDLES SADDLES SADDLES<br />

AVAILABLE IN A AVAILABLE IN A AVAILABLE IN A AVAILABLE IN A<br />

VARIETY OF VARIETY OF VARIETY OF VARIETY OF<br />

THICKNESSES THICKNESSES THICKNESSES THICKNESSES<br />

3.85/INCH @75 F 3.85/INCH @75 F 3.85/INCH @75 F 3.85/INCH @75 F<br />

PLYMOUTH, WI PLYMOUTH, WI PLYMOUTH, WI PLYMOUTH, WI<br />

BECKEE, MN BECKEE, MN BECKEE, MN BECKEE, MN<br />

BEACH CITY, OH BEACH CITY, OH BEACH CITY, OH BEACH CITY, OH<br />

225, 701, 801, 225, 701, 801, 225, 701, 801, 225, 701, 801,<br />

803, 914, 815, 803, 914, 815, 803, 914, 815, 803, 914, 815,<br />

817 817 817 817<br />

4169<br />

RADCO 1152; UL 458; RADCO 1152; UL 458; RADCO 1152; UL 458; RADCO 1152; UL 458; P 225, 701, 801, 803,<br />

UL 14021; FM 3D9A9.AM UL 14021; FM 3D9A9.AM UL 14021; FM 3D9A9.AM UL 14021; FM 3D9A9.AM 814, 815,817<br />

WI Approval 960017-I WI Approval 960017-I WI Approval 960017-I WI Approval 960017-I<br />

X<br />

441


Extruded Polystyrene <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME CARLISLE CARLISLE<br />

SYNTEC<br />

SYNTEC<br />

INCORPORATED INCORPORATED<br />

2. PRODUCT NAME DOW STYROFOAM DOW STYROFOAM<br />

DECKMATE DECKMATE PLUS<br />

3. NOMINAL DENSITY (lbs/ft³) 1.5 1.65<br />

4. COMPLIES WITH:<br />

ASTM C 578-95 Standard Specification for Rigid, Cellular Polystyrene<br />

Thermal Insulation (indicate Type IV, V, VI, VIII, X or XI)<br />

TYPE X<br />

TYPE IV<br />

5. PHYSICAL PROPERTIES (per ASTM D 578-95):<br />

Density, min., lbs/ft³ 1.35 1.6<br />

Compressive strength, min., psi 15 25<br />

Flexural strength, min., psi 40 50<br />

Water vapor permeance of 1.0 inch thickness, max., perm. 1.1 1.1<br />

Water absorption, max., volume % 0.3 0.3<br />

6. SURFACE TREATMENT:<br />

Top Surface CONTINUOUS CONTINUOUS<br />

CLOSED-CELL CLOSED-CELL<br />

EXTRUDED SKIN EXTRUDED SKIN<br />

Bot<strong>to</strong>m Surface CONTINUOUS CONTINUOUS<br />

CLOSED-CELL CLOSED-CELL<br />

EXTRUDED SKIN EXTRUDED SKIN<br />

7. AVAILABLE AS TAPERED MATERIAL (yes/no) YES YES<br />

8. COMMON AVAILABLE SIZES:<br />

2' X 4'<br />

3' X 4'<br />

4' X 4'<br />

4' X 8' X X<br />

Other (describe) 2' X 8' 2' X 8'<br />

9. COMMON AVAILABLE THICKNESSES/R-VALUES<br />

(indicate thickness, R-value for thickness at 40º F and R-value at 75º F) 1.0 IN -5.4 / 5.0 1.0 IN -5.4 / 5.0<br />

1.5 IN - 8.1 / 7.5 1.5 IN - 8.1 / 7.5<br />

2.0 IN - 10.8 / 10.0 2.0 IN - 10.8 / 10.0<br />

2.5 IN - 13.5 / 12.5 2.5 IN - 13.5 / 12.5<br />

3.0 IN - 16.2 / 15.0 3.0 IN - 16.2 / 15.0<br />

3.5 IN - 18.9 / 17.5 3.5 IN - 18.9 / 17.5<br />

4.0 IN - 21.6 / 20.0 4.0 IN - 21.6 / 20.0<br />

10. MANUFACTURING PLANT LOCATION(S)<br />

11. UL "P" DESIGN NUMBERS (indicate P-design numbers)<br />

12. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number) 96-52 96-52<br />

ICBO Evaluation Service, Inc. (indicate report number) 2257 2257<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number) 9576C 9576C<br />

Other agencies (indicate agency & report identification number) UL D369 UL D369<br />

FM APPROVED FM APPROVED<br />

13. LIMITATIONS AND/OR RESTRICTIONS SEE APPENDIX SEE APPENDIX<br />

14. SEE APPENDIX IF CHECKED X X<br />

442


Extruded Polystyrene <strong>Roof</strong> Insulation Board<br />

CARLISLE CARLISLE CARLISLE CARLISLE CARLISLE<br />

SYNTEC SYNTEC SYNTEC SYNTEC SYNTEC<br />

INCORPORATED INCORPORATED INCORPORATED INCORPORATED INCORPORATED<br />

DOW STYROFOAM DOW STYROFOAM DOW STYROFOAM FOAMULAR FOAMULAR<br />

ROOFMATE PLAZAMATE RECOVERMATE THERMAPINK 18 THERMAPINK 25<br />

1.9 2.2 2 1.4 1.65<br />

TYPE VI TYPE VII TYPE X TYPE IV<br />

1.8 2.2 2 1.3 1.6<br />

40 60 18 18 25<br />

60 75 90 60 70<br />

1.1 1.1 1.8 1.1 1.1<br />

0.3 0.3 0.6


Extruded Polystyrene <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME CARLISLE CARLISLE<br />

SYNTEC<br />

SYNTEC<br />

INCORPORATED INCORPORATED<br />

2. PRODUCT NAME FOAMULAR FOAMULAR<br />

THERMAPINK 40 DURAPINK<br />

3. NOMINAL DENSITY (lbs/ft³) 1.85 1.60<br />

4. COMPLIES WITH:<br />

ASTM C 578-95 Standard Specification for Rigid, Cellular Polystyrene<br />

Thermal Insulation (indicate Type IV, V, VI, VIII, X or XI)<br />

TYPE VI<br />

TYPE IV<br />

5. PHYSICAL PROPERTIES (per ASTM D 578-95):<br />

Density, min., lbs/ft³ 1.8 1.6<br />

Compressive strength, min., psi 40 25<br />

Flexural strength, min., psi 115 NA<br />

Water vapor permeance of 1.0 inch thickness, max., perm. 1.1 1.1<br />

Water absorption, max., volume %


Extruded Polystyrene <strong>Roof</strong> Insulation Board<br />

CARLISLE CARLISLE THE DOW THE DOW THE DOW<br />

SYNTEC SYNTEC CHEMICAL CHEMICAL CHEMICAL<br />

INCORPORATED INCORPORATED COMPANY COMPANY COMPANY<br />

FOAMULAR FOAMULAR STYROFOAM STYROFOAM STYROFOAM<br />

400 600 DECKMATE DECKMATE PLUS PLAZAMATE<br />

1.85 2.20 1.5 1.65 2.2<br />

TYPE VI TYPE VII TYPE X TYPE IV TYPE VII<br />

1.8 2.2 1.35 1.60 2.2<br />

40 60 15 25 60<br />

115 140 40 50 75<br />

1.1 1.1 1.1 1.0 1.1<br />


Extruded Polystyrene <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME THE DOW THE DOW<br />

CHEMICAL<br />

CHEMICAL<br />

COMPANY<br />

COMPANY<br />

2. PRODUCT NAME STYROFOAM STYROFOAM<br />

ROOFMATE<br />

HIGH LOAD<br />

100<br />

3. NOMINAL DENSITY (lbs/ft³) 1.9 3.0<br />

4. COMPLIES WITH:<br />

ASTM C 578-95 Standard Specification for Rigid, Cellular Polystyrene<br />

Thermal Insulation (indicate Type IV, V, VI, VIII, X or XI)<br />

TYPE VII<br />

TYPE V<br />

5. PHYSICAL PROPERTIES (per ASTM D 578-95):<br />

Density, min., lbs/ft³ 1.8 3.0<br />

Compressive strength, min., psi 40 100<br />

Flexural strength, min., psi 60 100<br />

Water vapor permeance of 1.0 inch thickness, max., perm. 1.1 1.1<br />

Water absorption, max., volume % 0.3 0.3<br />

6. SURFACE TREATMENT:<br />

Top Surface CONTINUOUS CONTINUOUS<br />

CLOSED-CELL CLOSED-CELL<br />

EXTRUDED SKIN EXTRUDED SKIN<br />

Bot<strong>to</strong>m Surface CONTINUOUS CONTINUOUS<br />

CLOSED-CELL CLOSED-CELL<br />

EXTRUDED SKIN EXTRUDED SKIN<br />

7. AVAILABLE AS TAPERED MATERIAL (yes/no) NO YES<br />

8. COMMON AVAILABLE SIZES:<br />

2' X 4'<br />

3' X 4'<br />

4' X 4'<br />

4' X 8'<br />

Other (describe) 2' X 8' 2' X 8'<br />

9. COMMON AVAILABLE THICKNESSES/R-VALUES<br />

(indicate thickness, R-value for thickness at 40º F and R-value at 75º F) 1.5 IN - 8.1 / 7.5 2 IN - 10.8 / 10.0<br />

2.0 IN - 10.8 / 10.0 3 IN - 16.2 / 15<br />

2.5 IN - 13.5 / 12.5<br />

3.0 IN - 16.2 / 15.0<br />

3.5 IN - 18.9 / 17.5<br />

4.0 IN - 21.6 / 20.0<br />

10. MANUFACTURING PLANT LOCATION(S) TORRANCE, CA TORRANCE, CA<br />

ALLYNS POINT, CT ALLYNS POINT, CT<br />

JOLIET, IL<br />

DALTON, GA<br />

PEVLEY, MO<br />

11. UL "P" DESIGN NUMBERS (indicate P-design numbers) SEE APPENDIX SEE APPENDIX<br />

12. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number) 96-52 96-52<br />

ICBO Evaluation Service, Inc. (indicate report number) 2257 2257<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number) 9576C 9576C<br />

Other agencies (indicate agency & report identification number) UL D369 UL D369<br />

FM APPROVED<br />

13. LIMITATIONS AND/OR RESTRICTIONS SEE APPENDIX SEE APPENDIX<br />

14. SEE APPENDIX IF CHECKED X X<br />

446


Extruded Polystyrene <strong>Roof</strong> Insulation Board<br />

THE DOW THE DOW GAF GAF GAF<br />

CHEMICAL CHEMICAL MATERIALS MATERIALS MATERIALS<br />

COMPANY COMPANY CORP. CORP. CORP.<br />

STYROFOAM STYROFOAOM EVERGUARD EVERGUARD EVERGUARD<br />

RECOVERMATE RECOVERMATE CR XPS XPS XPS<br />

FAN-FOLD RECOVER BOARD<br />

2.0 2.0 2.0 2.0 1.5<br />

TYPE IV TYPE IV TYPE X<br />

2.0 2.0 1.6 1.6 1.35<br />

18 15 25 25 15<br />

90 75 60<br />

1.8 0.6 1.1 1.1<br />

0.6 0.3 0.4 0.1 0.1<br />

CONTINUOUS POLYKRAFT PLASTIC CONTINUOUS CONTINUOUS<br />

CLOSED-CELL FACER CAP SHEET EXTRUDED SKIN EXTRUDED SKIN<br />

EXTRUDED SKIN<br />

CONTINUOUS POLYKRAFT PLASTIC CONTINUOUS CONTINUOUS<br />

CLOSED-CELL FACER CAP SHEET EXTRUDED SKIN EXTRUDED SKIN<br />

EXTRUDED SKIN<br />

NO NO NO NO YES<br />

X X X<br />

4' X 50' FANFOLD 4' X 50'<br />

0.5 IN - 2.3 / 2..2 3/8 IN - 1.7 / 1.5 3/8 IN - NA/ 1.5 0.5 IN - NA / 2.5 1.0 IN - NA / 15<br />

0.75 IN - NA / 3.75 1.5 IN - NA / 7.5<br />

1 IN - NA / 5.0 2.0 IN - NA / 10<br />

2.5 IN - NA / 12.5<br />

3.0 IN - NA / 15<br />

3.5 IN - NA / 17.5<br />

4.0 IN - NA / 20<br />

HANGING ROCK, OH GRAND RAPIDS, MI WINCHESTER, VA TALLMADGE, OH TALLMADGE, OH<br />

CHIPPEWA FALLS, WI ROCKFORD, IL ROCKFORD, IL<br />

YAKIMA, WA<br />

SEE APPENDIX SEE APPENDIX CONTACT GAF CONTACT GAF CONTACT GAF<br />

96-52 96-52<br />

2257 2257<br />

9576C<br />

UL D389<br />

FM APPROVED<br />

SEE APPENDIX<br />

X<br />

9576C<br />

UL D369<br />

SEE APPENDIX<br />

X<br />

447


Extruded Polystyrene <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME GAF OWENS<br />

MATERIALS<br />

CORNING<br />

CORP.<br />

2. PRODUCT NAME EVERGUARD THERMAPINK<br />

XPS-HD 18<br />

3. NOMINAL DENSITY (lbs/ft³) 2.0 1.40<br />

4. COMPLIES WITH:<br />

ASTM C 578-95 Standard Specification for Rigid, Cellular Polystyrene<br />

Thermal Insulation (indicate Type IV, V, VI, VIII, X or XI)<br />

TYPE IV<br />

TYPE X<br />

5. PHYSICAL PROPERTIES (per ASTM D 578-95):<br />

Density, min., lbs/ft³ 1.6 1.30<br />

Compressive strength, min., psi 25 18<br />

Flexural strength, min., psi 75 60<br />

Water vapor permeance of 1.0 inch thickness, max., perm. 1.1 1.1<br />

Water absorption, max., volume % 0.1


Extruded Polystyrene <strong>Roof</strong> Insulation Board<br />

OWENS OWENS OWENS OWENS OWENS<br />

CORNING CORNING CORNING CORNING CORNING<br />

THERMAPINK THERMAPINK THERMAPINK DURAPINK DURAPINK<br />

25 40 60 FA<br />

1.65 1.85 2.20 1.60 1.60<br />

TYPE IV TYPE VI TYPE VII TYPE IV TYPE IV<br />

1.60 1.80 2.20 1.60 1.60<br />

25 40 60 25 25<br />

70 115 140 NA 75<br />

1.1 1.1 1.1 1.1


Extruded Polystyrene <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME OWENS OWENS<br />

CORNING<br />

CORNING<br />

2. PRODUCT NAME DURAPINK FOAMULAR<br />

PLUS 404<br />

3. NOMINAL DENSITY (lbs/ft³) 1.50 1.85<br />

4. COMPLIES WITH:<br />

ASTM C 578-95 Standard Specification for Rigid, Cellular Polystyrene<br />

Thermal Insulation (indicate Type IV, V, VI, VIII, X or XI)<br />

TYPE IV<br />

TYPE VI<br />

5. PHYSICAL PROPERTIES (per ASTM D 578-95):<br />

Density, min., lbs/ft³ 1.50 1.80<br />

Compressive strength, min., psi 18 40<br />

Flexural strength, min., psi 80 115<br />

Water vapor permeance of 1.0 inch thickness, max., perm.


Extruded Polystyrene <strong>Roof</strong> Insulation Board<br />

OWENS OWENS OWENS OWENS OWENS<br />

CORNING CORNING CORNING CORNING CORNING<br />

FOAMULAR FOAMULAR FOAMULAR FOAMULAR FOAMULAR<br />

604 404 RB 604 RB 150 250<br />

2.20 1.85 2.20 1.40 1.65<br />

TYPE VII TYPE VI TYPE VII TYPE X TYPE IV<br />

2.20 1.80 2.20 1.30 1.60<br />

60 40 60 15 25<br />

140 115 140 60 75<br />

1.1 1.1 1.1 1.1 1.1<br />


Extruded Polystyrene <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME OWENS OWENS<br />

CORNING<br />

CORNING<br />

2. PRODUCT NAME FOAMULAR FOAMULAR<br />

400 600<br />

3. NOMINAL DENSITY (lbs/ft³) 1.85 2.20<br />

4. COMPLIES WITH:<br />

ASTM C 578-95 Standard Specification for Rigid, Cellular Polystyrene<br />

Thermal Insulation (indicate Type IV, V, VI, VIII, X or XI)<br />

TYPE VI<br />

TYPE VII<br />

5. PHYSICAL PROPERTIES (per ASTM D 578-95):<br />

Density, min., lbs/ft³ 1.8 2.20<br />

Compressive strength, min., psi 40 60<br />

Flexural strength, min., psi 115 140<br />

Water vapor permeance of 1.0 inch thickness, max., perm. 1.1 1.1<br />

Water absorption, max., volume %


Extruded Polystyrene <strong>Roof</strong> Insulation Board<br />

OWENS PACTIV PACTIV PACTIV<br />

CORNING BUILDING BUILDING BUILDING<br />

PRODUCTS PRODUCTS PRODUCTS<br />

FOAMULAR AMOCOR PLYGOOD- PG38 / AMOFOAM<br />

1000 PB-6 / PB6W / PG 39<br />

PB 6 PLUS<br />

3.00<br />

TYPE V<br />

3.00<br />

100<br />

140<br />

1.1<br />


Glass Fiber <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME JOHNS<br />

MANVILLE<br />

INTERNATIONAL<br />

2. PRODUCT NAME FIBER GLASS<br />

3. COMPLIES WITH:<br />

ASTM 726-93 Standard Specification for Mineral Fiber <strong>Roof</strong> Insulation Board<br />

(indicate X)<br />

4. PHYSICAL PROPERTIES (per ASTM C726-93):<br />

Compressive strength, min., psi 12 12<br />

Tensile strength perpendicular <strong>to</strong> board surface, min., lbf/ft² 100<br />

Breaking load, min., lbf 20<br />

Water absorption, max., volume % 10 10<br />

5. SURFACE TREATMENT:<br />

Top Surface<br />

X<br />

ASPHALT AND<br />

KRAFT<br />

Bot<strong>to</strong>m Surface<br />

NONE<br />

NON<br />

6. AVAILABLE AS TAPERED MATERIAL (yes/no)<br />

7. COMMON AVAILABLE SIZES:<br />

2' X 4'<br />

3' X 4'<br />

4' X 4' X<br />

4' X 8' X<br />

Other (describe)<br />

8. COMMON AVAILABLE THICKNESSES/R-VALUES (indicate thickness,<br />

R-value for thickness at 40º F and R-value at 75º F) 0.75 IN - NA / 2.78<br />

0.938 IN - NA / 3.70<br />

1.063 IN - NA / 4.17<br />

1.63 IN - NA / 6.67<br />

2.0 IN - NA / 8.0<br />

2.25 IN - NA / 9.09<br />

3.0 IN - NA / 12.50<br />

9. MANUFACTURING PLANT LOCATION(S) NEWARK, OH<br />

10. UL "P" DESIGN NUMBERS (indicate P-design numbers) SEE APPENDIX<br />

11. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number)<br />

ICBO Evaluation Service, Inc. (indicate report number)<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number)<br />

Other agencies (indicate agency & report identification number)<br />

12. LIMITATIONS AND/OR RESTRICTIONS SEE APPENDIX<br />

13. SEE APPENDIX IF CHECKED X<br />

454


Glass Mat-faced Gypsum Board<br />

1. COMPANY NAME FIRESTONE G-P GYPSUM<br />

BUILDING<br />

CORPORATION<br />

PRODUCTS<br />

2. PRODUCT NAME 3/8 INCH 1/4 INCH<br />

DENS-DECK<br />

DENS-DECK<br />

ROOF BOARD<br />

3. NOMINAL DENSITY (lbs/ft³) 47 50<br />

4. COMPLIES WITH:<br />

ASTM C 1177-99, Standard Specification for Glass Mat Gypsum Substrate<br />

for Use as Sheathing<br />

5. PHYSICAL PROPERTIES (per ASTM C 1177-99):<br />

Flexural strength, min., lbf 50<br />

Humidified Reflection, Max., IN.<br />

NA<br />

Core, End and Edge Hardness, Min., 15 lbf. 15<br />

Nail-pull Resistance, Min., Lbf. 40<br />

Water Resistance, Max., Weight % 10<br />

6. SURFACE TREATMENT:<br />

Top Surface GLASS MAT GLASS MAT<br />

NO<br />

YES<br />

Bot<strong>to</strong>m Surface GLASS MAT GLASS MAT<br />

7. AVAILABLE AS TAPERED MATERIAL (yes/no) NO NO<br />

8. COMMON AVAILABLE SIZES:<br />

2' X 4'<br />

3' X 4'<br />

4' X 4' X X<br />

4' X 8' X X<br />

Other (describe)<br />

9. COMMON AVAILABLE THICKNESSES/R-VALUES (indicate<br />

thickness, R-value for thickness at 40º F and R-value at 75º F) 3/8 IN - 0.42 1/4 IN - 0.28<br />

10. MANUFACTURING PLANT LOCATION(S) TEXAS TEXAS<br />

NEVADA<br />

11. UL "P" DESIGN NUMBERS (indicate P-design number)<br />

12. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number)<br />

ICBO Evaluation Service, Inc. (indicate report number)<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number)<br />

Other agencies (indicate agency & report identification number)<br />

13. LIMITATIONS AND/OR RESTRICTIONS<br />

14. SEE APPENDIX IF CHECKED<br />

456


Glass Mat-faced Gypsum Board<br />

G-P GYPSUM<br />

CORPORATION<br />

G-P GYPSUM<br />

CORPORATION<br />

1/2 INCH 5/8 INCH<br />

DENS-DECK<br />

DENS-DECK<br />

ROOF BOARD ROOF BOARD<br />

80 100<br />

YES<br />

YES<br />

80 100<br />

218 118<br />

15 15<br />

80 90<br />

10 10<br />

GLASS MAT<br />

GLASS MAT<br />

GLASS MAT<br />

GLASS MAT<br />

NO<br />

NO<br />

X<br />

X<br />

X<br />

X<br />

1/2 IN - 0.56 5/8 IN - 0.67<br />

TEXAS<br />

NEVADA<br />

TEXAS<br />

NEVADA<br />

SEE APPENDIX<br />

X<br />

457


Perlite <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME GAF<br />

MATERIALS<br />

CORP.<br />

2. PRODUCT NAME GAFTEMP<br />

PERMALITE<br />

3. COMPLIES WITH:<br />

ASTM C 728-97 Standard Specification for Perlite Thermal Insulation<br />

Board (indicate Type 1 or Type 2)<br />

TYPE I<br />

4. PHYSICAL PROPERTIES (per ASTM C728-97):<br />

Density, min., lbs/ft³ Type 1: 8; Type 2: 10 8<br />

Compressive strength, min., psi 20 20<br />

Tensile strength, perpendicular, min., lbf/ft² Type 1: 575; Type 2: 700 575<br />

Flexural strength, min., psi Type 1: 40; Type 2: 60 40<br />

Water absorption, max., volume % Type 1: 1.5; Type 2: 3.5 1.5<br />

5. SURFACE TREATMENT:<br />

Top Surface<br />

COATED<br />

Bot<strong>to</strong>m Surface<br />

NONE<br />

6. AVAILABLE AS TAPERED MATERIAL (yes/no) NO<br />

7. COMMON AVAILABLE SIZES:<br />

2' X 4' X<br />

3' X 4'<br />

4' X 4' X<br />

4' X 8'<br />

Other (describe)<br />

8. COMMON AVAILABLE THICKNESSES/R-VALUES (indicate thickness,<br />

R-value for thickness at 40º F and R-value at 75º F) 0.75 IN - NA / 2.08<br />

1.0 IN - NA / 2.78<br />

1.5 IN - NA / 4.17<br />

2.0 IN - NA / 5.56<br />

3.0 IN - NA / 8.33<br />

9. MANUFACTURING PLANT LOCATION(S)<br />

10. UL "P" DESIGN NUMBERS (indicate P-design numbers) SEE APPENDIX<br />

11. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number)<br />

ICBO Evaluation Service, Inc. (indicate report number)<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number)<br />

Other agencies (indicate agency & report identification number)<br />

12. LIMITATIONS AND/OR RESTRICTIONS SEE APPENDIX<br />

13. SEE APPENDIX IF CHECKED X<br />

458


Perlite <strong>Roof</strong> Insulation Board<br />

GAF JOHNS JOHNS JOHNS KOPPERS<br />

MATERIALS MANVILLE MANVILLE MANVILLE INDUSTRIES<br />

CORP. INTERNATIONAL INTERNATIONAL INTERNATIONAL<br />

1/2" RECOVER FESCO 1/2 INCH DURABOARD PERLITE<br />

BOARD BOARD RETROFIT BOARD<br />

TYPE I TYPE I TYPE II TYPE I<br />

8 9 10 9<br />

20 20 35 30<br />

575 575 700<br />

40 40 60 65<br />

1.5 1.5 3.5 1.5<br />

COATED COATED COATED COATED COATED<br />

NONE NONE NONE NONE NONE<br />

NO<br />

YES<br />

X X X X<br />

X X X X X<br />

X X X<br />

X<br />

0.5 IN - NA / 1.32 0.75 IN - NA / 2.08 0.5IN - NA / 1.32 0.5 IN - NA / 1.2 0.75 IN - NA / 2.08<br />

1.0 IN - NA / 2.78 0.75 IN - NA / 1.8 1.0 IN - NA / 2.78<br />

1.5 IN - NA / 4.17 1.0 IN - NA / 2.3 1.5 IN - NA / 4.17<br />

2.0 IN - NA / 5.56<br />

3.0 IN - NA / 8.33<br />

ROCKDALE, IL ROCKDALE, IL EDINBURG, VA<br />

NATCHEZ, MS NATCHEZ, MS<br />

EDINBURG, VA EDINBURG, VA<br />

SEE APPENDIX<br />

SEE UL LISTING<br />

X X<br />

459


Polyisocyanurate <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME ATLAS<br />

ROOFING<br />

CORPORATION<br />

2. PRODUCT NAME ACFOAM-II<br />

3. COMPLIES WITH:<br />

3A. ASTM C 1289-98 Standard Specification for Faced Rigid Cellular<br />

Polyisocyanurate Thermal Insulation Board (indicate Type I, Class 1; Type<br />

TYPE II<br />

I Class 2, Type III; Type IV; Type V or Type VI)<br />

3B. CAN/CGSB-51.26-M86 Thermal Insulation, Urethane and Isocyanurate,<br />

Boards, Faced (no response or indicate Type 1, 2, 3 or 4)<br />

TYPE 2<br />

3C. CAN/ULC-S704 Standard for Thermal Insulation, Polyurethane and<br />

Polyisocyanurate, Boards Faced (no response or indicate X)<br />

4. PHYSICAL PROPERTIES (per ASTM C 1289-98)<br />

Compressive strength, min., psi 16 16<br />

Dimensional stability, % linear change, max., 158ºF/97%RH Type I, Class 1: 2.0; Type I, Class 2: 1.5; Type II-VI: 4.0<br />

4.0<br />

Flexural strength, min., psi Type I-V: 40; Type VI 50 40<br />

Tensile strength (perpendicular <strong>to</strong> board surface) min., psf 500 500<br />

Water absorption, max., volume % Type I, III and V: 1.0; Type II and VI: 1.5; Type IV: 2.0<br />

1.5<br />

5. SURFACE TREATMENT:<br />

Top Surface<br />

GLASS FIBER<br />

REINFORCED FELT<br />

Bot<strong>to</strong>m Surface<br />

GLASS FIBER<br />

REINFORCED FELT<br />

6. AVAILABLE AS TAPERED MATERIAL (yes/no) YES<br />

7. COMMON AVAILABLE SIZES:<br />

2' X 4'<br />

3' X 4'<br />

4' X 4' X<br />

4' X 8' X<br />

Other (describe)<br />

FLUTE FILL<br />

8. COMMON AVAILABLE THICKNESSES/R-VALUES (indicate thickness,<br />

R-value for thickness at 40º F and R-value at 75º F) 1.0 IN - 6.7 / 6.0<br />

1.5 IN - 11.1 / 10.0<br />

2.0 IN - 15.9 / 14.3<br />

2.7 IN - 22.2 / 20.0<br />

9. MANUFACTURING PLANT LOCATION(S) MESA, AZ; DIBOLL, TX<br />

LA GRANGE, GA<br />

CAMP HILL, PA<br />

E. MOLINE, IL<br />

NORTHGLENN, CO<br />

ETOBICOKE, ONTARIO<br />

10. UL "P" DESIGN NUMBERS (indicate P-design numbers) SEE APPENDIX<br />

11. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number)<br />

ICBO Evaluation Service, Inc. (indicate report number)<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number)<br />

Other agencies (indicate agency & report identification number)<br />

SEE APPENDIX<br />

12. LIMITATIONS AND/OR RESTRICTIONS SEE APPENDIX<br />

13. SEE APPENDIX IF CHECKED X<br />

460


Polyisocyanurate <strong>Roof</strong> Insulation Board<br />

ATLAS ATLAS ATLAS ATLAS ATLAS<br />

ROOFING ROOFING ROOFING ROOFING ROOFING<br />

CORPORATION CORPORATION CORPORATION CORPORATION CORPORATION<br />

ACFOAM - III ACFOAM ACFOAM ACFOAM ACFOAM NAIL<br />

SUPREME RECOVER COMPOSITE BASE INSULATION<br />

BOARD<br />

TYPE II TYPE I, CLASS I TYPE II TYPE II TYPE V<br />

TYPE 2 TYPE 2 TYPE 2<br />

16 16 16 16 16<br />

4.0 2.0 4.0 4.0 4.0<br />

40 40 40 40 40<br />

500 500 500 500 500<br />

1.5 1.0 1.5 1.0 1.0<br />

COATED GLASS TRI-LAMINATE COATED GLASS PERLITE OSB<br />

FIBER MAT FOIL FIBER MAT<br />

COATED GLASS TRI-LAMINATE COATED GLASS GLASS FIBER GLASS FIBER<br />

FIBER MAT FOIL FIBER MAT REINFORCED FELT REINFORCED FELT<br />

YES NO NO YES NO<br />

X X X<br />

X X X X X<br />

X<br />

1.0 IN - 6.7 / 6.0 1.0 IN - 8.3 / 7.2 1.0 IN - 6.7 / 6.0 1.5 IN - 7.4 1.5 IN -7.3<br />

1.5 IN - 11.1 / 10.0 1.5 IN - 12.4 / 11.2 2.0 IN - 11.4 2.0 IN - 11.3<br />

2.0 IN - 15.9 / 14.3 2.0 IN - 16.9 / 15.2 2.7 IN - 15.7 2.7 IN - 15.5<br />

2.7 IN - 22.2 / 20.0 2.7 IN - 22.4 / 20.2<br />

MESA, AZ; DIBOLL, TX MESA, AZ; DIBOLL, TX MESA, AZ; DIBOLL, TX MESA, AZ; DIBOLL, TX MESA, AZ; DIBOLL, TX<br />

LA GRANGE, GA LA GRANGE, GA LA GRANGE, GA LA GRANGE, GA LA GRANGE, GA<br />

CAMP HILL, PA CAMP HILL, PA CAMP HILL, PA CAMP HILL, PA CAMP HILL, PA<br />

E. MOLINE, IL E. MOLINE, IL E. MOLINE, IL E. MOLINE, IL E. MOLINE, IL<br />

NORTHGLENN, CO NORTHGLENN, CO NORTHGLENN, CO NORTHGLENN, CO NORTHGLENN, CO<br />

ETOBICOKE, ONTARIO ETOBICOKE, ONTARIO ETOBICOKE, ONTARIO ETOBICOKE, ONTARIO ETOBICOKE, ONTARIO<br />

SEE APPENDIX SEE APPENDIX SEE APPENDIX SEE APPENDIX<br />

SEE APPENDIX SEE APPENDIX SEE APPENDIX SEE APPENDIX<br />

SEE APPENDIX SEE APPENDIX<br />

X X X X X<br />

461


Polyisocyanurate <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME ATLAS<br />

ROOFING<br />

CORPORATION<br />

2. PRODUCT NAME AC FOAM<br />

VENTED-R<br />

3. COMPLIES WITH:<br />

3A. ASTM C 1289-98 Standard Specification for Faced Rigid Cellular<br />

Polyisocyanurate Thermal Insulation Board (indicate Type I, Class 1; Type<br />

TYPE V<br />

I Class 2, Type II, Type III; Type IV; Type V or Type VI)<br />

3B. CAN/CGSB-51.26-M86 Thermal Insulation, Urethane and Isocyanurate,<br />

Boards, Faced (no response or indicate Type 1, 2, 3 or 4)<br />

TYPE 2<br />

3C. CAN/ULC-S704 Standard for Thermal Insulation, Polyurethane and<br />

Polyisocyanurate, Boards Faced (no response or indicate X)<br />

4. PHYSICAL PROPERTIES (per ASTM C 1289-98)<br />

Compressive strength, min., psi 16 16<br />

Dimensional stability, % linear change, max., 158ºF/97%RH Type I, Class 1: 2.0; Type I, Class 2: 1.5; Type II-VI: 4.0<br />

4.0<br />

Flexural strength, min., psi Type I-V: 40; Type VI 50 40<br />

Tensile strength (perpendicular <strong>to</strong> board surface) min., psf 500 500<br />

Water absorption, max., volume % Type I, III and V: 1.0; Type II and VI: 1.5; Type IV: 2.0<br />

1.0<br />

5. SURFACE TREATMENT:<br />

Top Surface<br />

OSB WITH<br />

VENT SPACERS<br />

Bot<strong>to</strong>m Surface<br />

GLASS FIBER<br />

REINFORCED FELT<br />

6. AVAILABLE AS TAPERED MATERIAL (yes/no) NO<br />

7. COMMON AVAILABLE SIZES:<br />

2' X 4'<br />

3' X 4'<br />

4' X 4'<br />

4' X 8' X<br />

Other (describe)<br />

8. COMMON AVAILABLE THICKNESSES/R-VALUES (indicate thickness,<br />

R-value for thickness at 40º F and R-value at 75º F) 2.2 IN - 7.4<br />

2.5 IN -9.7<br />

3.0 IN - 13.9<br />

5.0 IN - 29.4<br />

9. MANUFACTURING PLANT LOCATION(S) MESA, AZ; DIBOLL, TX<br />

LA GRANGE, GA<br />

CAMP HILL, PA<br />

E. MOLINE, IL<br />

NORTHGLENN, CO<br />

ETOBICOKE, ONTARIO<br />

10. UL "P" DESIGN NUMBERS (indicate P-design numbers) SEE APPENDIX<br />

11. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number)<br />

ICBO Evaluation Service, Inc. (indicate report number)<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number)<br />

Other agencies (indicate agency & report identification number)<br />

SEE APPENDIX<br />

12. LIMITATIONS AND/OR RESTRICTIONS SEE APPENDIX<br />

13. SEE APPENDIX IF CHECKED X<br />

462


Polyisocyanurate <strong>Roof</strong> Insulation Board<br />

ATLAS CARLISLE CARLISLE CARLISLE CARLISLE<br />

ROOFING SYNTEC SYNTEC SYNTEC SYNTEC<br />

CORPORATION INCORPORATED INCORPORATED INCORPORATED INCORPORATED<br />

GEMINI POLYISO HP POLYISO HP-H POLYISO HP-N POLYISO HP-W<br />

CRICKET<br />

TYPE II TYPE II TYPE II TYPE II TYPE II<br />

16 16 16 16 16<br />

4.0 4.0 4.0 4.0 4.0<br />

40 40 40 40 40<br />

500 500 500 500 500<br />

1.0 1.5 1.5 1.5 1.5<br />

GLASS FIBER NONE NONE NONE NONE<br />

REINFORCED FELT<br />

GLASS FIBER NONE NONE NONE NONE<br />

REINFORCED FELT<br />

YES YES YES YES YES<br />

X X X X<br />

X X X X<br />

1 IN - 6.7 / 6.0 1 IN - 6.0 1 IN - 6.0 1 IN - 6.0 1 IN - 6.0<br />

1.5 IN - 10.0 1.5 IN - 10.0 1.5 IN - 10.0 1.5 IN - 10.0<br />

2.0 - 14.3 2.0 - 14.3 2.0 - 14.3 2.0 - 14.3<br />

2.5 IN - 19.0 2.5 IN - 19.0 2.5 IN - 19.0 2.5 IN - 19.0<br />

3.0 - 23.0 3.0 - 23.0 3.0 - 23.0 3.0 - 23.0<br />

MESA, AZ; DIBOLL, TX<br />

LA GRANGE, GA<br />

CAMP HILL, PA<br />

E. MOLINE, IL<br />

NORTHGLENN, CO<br />

ETOBICOKE, ONTARIO<br />

SEE APPENDIX<br />

98-1 98-1 98-1 98-1<br />

ER-3826; ER-5227 ER-3826; ER-5227 ER-3826; ER-5227 ER-3826; ER-5227<br />

NER-570 NER-570 NER-570 NER-570<br />

ER-9947 ER-9947 ER-9947 ER-9947<br />

SEE APPENDIX DADE COUNTY DADE COUNTY DADE COUNTY DADE COUNTY<br />

NEW YORK CITY NEW YORK CITY NEW YORK CITY NEW YORK CITY<br />

SEE APPENDIX SEE APPENDIX SEE APPENDIX SEE APPENDIX SEE APPENDIX<br />

X X X X X<br />

463


Polyisocyanurate <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME FIRESTONE<br />

BUILDING<br />

PRODUCTS<br />

2. PRODUCT NAME ISOP 95+<br />

ISOCYANURATE<br />

3. COMPLIES WITH:<br />

3A. ASTM C 1289-98 Standard Specification for Faced Rigid Cellular<br />

Polyisocyanurate Thermal Insulation Board (indicate Type I, Class 1; Type<br />

TYPE II<br />

I Class 2, Type II, Type III; Type IV; Type V or Type VI)<br />

3B. CAN/CGSB-51.26-M86 Thermal Insulation, Urethane and Isocyanurate,<br />

Boards, Faced (no response or indicate Type 1, 2, 3 or 4)<br />

TYPE 2<br />

3C. CAN/ULC-S704 Standard for Thermal Insulation, Polyurethane and<br />

Polyisocyanurate, Boards Faced (no response or indicate X)<br />

4. PHYSICAL PROPERTIES (per ASTM C 1289-98)<br />

Compressive strength, min., psi 16 20<br />

Dimensional stability, % linear change, max., 158ºF/97%RH Type I, Class 1: 2.0; Type I, Class 2: 1.5; Type II-VI: 4.0<br />

2<br />

Flexural strength, min., psi Type I-V: 40; Type VI 50 40<br />

Tensile strength (perpendicular <strong>to</strong> board surface) min., psf 500 500<br />

Water absorption, max., volume % Type I, III and V: 1.0; Type II and VI: 1.5; Type IV: 2.0<br />

1.5<br />

5. SURFACE TREATMENT:<br />

Top Surface<br />

GLASS REINFORCED<br />

ORGANIC MAT<br />

Bot<strong>to</strong>m Surface<br />

GLASS REINFORCED<br />

ORGANIC MAT<br />

6. AVAILABLE AS TAPERED MATERIAL (yes/no) YES<br />

7. COMMON AVAILABLE SIZES:<br />

2' X 4'<br />

3' X 4'<br />

4' X 4' X<br />

4' X 8' X<br />

Other (describe)<br />

8. COMMON AVAILABLE THICKNESSES/R-VALUES (indicate thickness,<br />

R-value for thickness at 40º F and R-value at 75º F) 1 IN - 6<br />

1.5 IN - 10<br />

2 IN - 14.3<br />

2.7 IN - 20<br />

3 IN - 22<br />

3.5 IN - 25.8<br />

4 IN - 30<br />

9. MANUFACTURING PLANT LOCATION(S) CO; CT;<br />

FL; KY;<br />

PA; TX;<br />

UT; WI<br />

10. UL "P" DESIGN NUMBERS (indicate P-design numbers) SEE APPENDIX<br />

11. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number)<br />

ICBO Evaluation Service, Inc. (indicate report number)<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number) 9595<br />

Other agencies (indicate agency & report identification number)<br />

12. LIMITATIONS AND/OR RESTRICTIONS<br />

13. SEE APPENDIX IF CHECKED X<br />

464


Polyisocyanurate <strong>Roof</strong> Insulation Board<br />

GAF GAF GAF JOHNS JOHNS<br />

MATERIALS MATERIALS MATERIALS MANVILLE MANVILLE<br />

CORPORATION CORPORATION CORPORATION INTERNATIONAL INTERNATIONAL<br />

EVERGUARD EVERGAURD EVERGAURD E"NRG"Y.2 ISO-1<br />

ISO ISO ISO - HD<br />

RECOVERBOARD<br />

TYPE II TYPE II TYPE II TYPE II TYPE II<br />

TYPE 1 TYPE 1<br />

TYPE 3 TYPE 3<br />

16 20 25 20 20<br />

2.0 2.0 2.0 40<br />

>500 >500<br />

1.0 1.0 1.0


Polyisocyanurate <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME KOPPERS<br />

INDUSTRIES<br />

2. PRODUCT NAME KOP-R<br />

ISOCYANURATE<br />

3. COMPLIES WITH:<br />

3A. ASTM C 1289-98 Standard Specification for Faced Rigid Cellular<br />

Polyisocyanurate Thermal Insulation Board (indicate Type I, Class 1; Type<br />

I Class 2, Type II, Type III; Type IV; Type V or Type VI)<br />

3B. CAN/CGSB-51.26-M86 Thermal Insulation, Urethane and Isocyanurate,<br />

Boards, Faced (no response or indicate Type 1, 2, 3 or 4)<br />

3C. CAN/ULC-S704 Standard for Thermal Insulation, Polyurethane and<br />

Polyisocyanurate, Boards Faced (no response or indicate X)<br />

4. PHYSICAL PROPERTIES (per ASTM C 1289-98)<br />

Compressive strength, min., psi 16 20<br />

Dimensional stability, % linear change, max., 158ºF/97%RH Type I, Class 1: 2.0; Type I, Class 2: 1.5; Type II-VI: 4.0


Polyisocyanurate <strong>Roof</strong> Insulation Board<br />

RMAX RMAX RMAX RMAX TREMCO<br />

INC INC INC INC INCORPORATED<br />

MULTI-MAX FA MULTI-MAX TAPERED TAPERED TRISOTECH<br />

THERMAROOF THERMAROOF G<br />

PLUS<br />

TYPE II TYPE II TYPE II TYPE I, CLASS I TYPE II, CLASS I<br />

TYPE 1<br />

16 16 16 16 20<br />

500 >500 >500 >500 500<br />


Polyisocyanurate <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME U.S. INTEC<br />

2. PRODUCT NAME GAFTEMP<br />

ISO THERM<br />

3. COMPLIES WITH:<br />

3A. ASTM C 1289-98 Standard Specification for Faced Rigid Cellular<br />

Polyisocyanurate Thermal Insulation Board (indicate Type I, Class 1; Type<br />

I Class 2, Type II, Type III; Type IV; Type V or Type VI)<br />

3B. CAN/CGSB-51.26-M86 Thermal Insulation, Urethane and Isocyanurate,<br />

Boards, Faced (no response or indicate Type 1, 2, 3 or 4)<br />

3C. CAN/ULC-S704 Standard for Thermal Insulation, Polyurethane and<br />

Polyisocyanurate, Boards Faced (no response or indicate X)<br />

4. PHYSICAL PROPERTIES (per ASTM C 1289-98)<br />

Compressive strength, min., psi 16<br />

Dimensional stability, % linear change, max., 158ºF/97%RH Type I, Class 1: 2.0; Type I, Class 2: 1.5; Type II-VI: 4.0<br />

Flexural strength, min., psi Type I-V: 40; Type VI 50<br />

Tensile strength (perpendicular <strong>to</strong> board surface) min., psf 500<br />

Water absorption, max., volume % Type I, III and V: 1.0; Type II and VI: 1.5; Type IV: 2.0<br />

5. SURFACE TREATMENT:<br />

Top Surface<br />

Bot<strong>to</strong>m Surface<br />

TYPE II<br />

COMPOSITE<br />

FACER<br />

COMPOSITE<br />

FACER<br />

6. AVAILABLE AS TAPERED MATERIAL (yes/no) YES<br />

7. COMMON AVAILABLE SIZES:<br />

2' X 4'<br />

3' X 4'<br />

4' X 4'<br />

4' X 8'<br />

Other (describe)<br />

8. COMMON AVAILABLE THICKNESSES/R-VALUES (indicate thickness,<br />

R-value for thickness at 40º F and R-value at 75º F)<br />

9. MANUFACTURING PLANT LOCATION(S)<br />

10. UL "P" DESIGN NUMBERS (indicate P-design numbers) SEE APPENDIX<br />

11. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number)<br />

ICBO Evaluation Service, Inc. (indicate report number)<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number)<br />

Other agencies (indicate agency & report identification number)<br />

12. LIMITATIONS AND/OR RESTRICTIONS<br />

13. SEE APPENDIX IF CHECKED X<br />

468


Wood Fiberboard <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME CARLISLE FIRESTONE<br />

SYNTEC<br />

BUILDING<br />

INCORPORATED PRODUCTS, INC.<br />

2. PRODUCT NAME HP RECOVERY FIBER TAP<br />

BOARD<br />

3. DENSITY (indicate Normal or High) HIGH HIGH<br />

4. COMPLIES WITH:<br />

ASTM C 208-95 Standard Specification for Cellulosic Fiber Insulating<br />

Board (indicate Type II, Grade 1 or Type II, Grade 2)<br />

5. SURFACE TREATMENT:<br />

Top Surface<br />

TYPE II, GRADE 2 TYPE II, GRADE 2<br />

ASPHALT<br />

EMULSION<br />

Bot<strong>to</strong>m Surface<br />

NONE<br />

6. AVAILABLE AS TAPERED MATERIAL (yes/no) NO NO<br />

7. COMMON AVAILABLE SIZES:<br />

2' X 4'<br />

3' X 4'<br />

4' X 4' X X<br />

4' X 8' X X<br />

Other (describe)<br />

8. COMMON AVAILABLE THICKNESSES/R-VALUES<br />

(indicate thickness, R-value for thickness at 40º F and R-value at 75º F)<br />

9. MANUFACTURING PLANT LOCATION(S) PENNSYLVANIA<br />

LOUISIANA<br />

VIRGINIA<br />

MINNESOTA<br />

OREGON<br />

10. UL "P" DESIGN NUMBERS (indicate P-design numbers)<br />

11. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number) 98-1<br />

ICBO Evaluation Service, Inc. (indicate report number)<br />

ER-3826, ER-5527<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

NER-570<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number) ER-9947<br />

Other agencies (indicate agency & report identification number)<br />

DADE COUNTY<br />

NEW YORK CITY<br />

12. LIMITATIONS AND/OR RESTRICTIONS SEE APPENDIX<br />

13. SEE APPENDIX IF CHECKED X<br />

470


Wood Fiberboard <strong>Roof</strong> Insulation Board<br />

GAF GAF HUEBERT HUEBERT KOPPERS<br />

MATERIALS MATERIALS FIBERBOARD FIBERBOARD INDUSTRIES,<br />

CORPORATION CORPORATION COMPANY COMPANY INC.<br />

GAFTEMP GAFTEMP REGULAR HIGH DENSITY REGULAR<br />

FIBERBOARD FIBERBOARD DENSITY ROOF COATED ROOF FIBERBOARD<br />

INSULATION INSULATION<br />

NORMAL HIGH NORMAL HIGH NORMAL<br />

TYPE I TYPE II GRADE I<br />

SURFACE SURFACE NONE ASPHALT ASPHALT<br />

TREATMENT TREATMENT EMULSION EMULSION<br />

NONE NONE NONE NONE NONE<br />

NO<br />

X X X X<br />

X X X X X<br />

X X X X X<br />

CUSTOM<br />

CUSTOM<br />

0.5 IN - 1.38 0.5 IN - 1.39 0.5 IN - NA / 1.25<br />

0.75 IN - 2.08 0.75 IN - 2.08<br />

1.0 IN - 2.78 1.0 IN - 2.78<br />

1.5 IN - 4.17 1.5 IN - 4.17<br />

2.0 IN - 5.26 2.0 IN - 5.26<br />

BOONVILLE, MO<br />

BOONVILLE, MO<br />

SEE CURRENT<br />

UL LISTING<br />

X<br />

471


Wood Fiberboard <strong>Roof</strong> Insulation Board<br />

1. COMPANY NAME KOPPERS TEMPLE<br />

INDUSTRIES,<br />

INC.<br />

2. PRODUCT NAME HIGH FIBERBASE<br />

DENSITY<br />

FIBERBOARD<br />

3. DENSITY (indicate Normal or High) HIGH HIGH<br />

4. COMPLIES WITH:<br />

ASTM C 208-95 Standard Specification for Cellulosic Fiber Insulating<br />

Board (indicate Type II, Grade 1 or Type II, Grade 2)<br />

GRADE 2 TYPE II, GRADE 1/2<br />

5. SURFACE TREATMENT:<br />

Top Surface ASPHALT ASPHALT<br />

EMULSION<br />

COATED<br />

Bot<strong>to</strong>m Surface<br />

NONE<br />

6. AVAILABLE AS TAPERED MATERIAL (yes/no) NO NO<br />

7. COMMON AVAILABLE SIZES:<br />

2' X 4' X<br />

3' X 4'<br />

4' X 4' X<br />

4' X 8' X X<br />

Other (describe)<br />

8. COMMON AVAILABLE THICKNESSES/R-VALUES<br />

(indicate thickness, R-value for thickness at 40º F and R-value at 75º F) 0.5 IN - NA / 1.28 0.5 IN - 1.32 / 0.75<br />

0.75 IN - NA / 2.10 15/32 IN - 2.06 / 1.35<br />

1.0 IN - NA / 2.78<br />

9. MANUFACTURING PLANT LOCATION(S) DIBOLL, TX<br />

10. UL "P" DESIGN NUMBERS (indicate P-design numbers) SEE CURRENT 517<br />

UL LISTING<br />

11. CODE ACCEPTANCE:<br />

BOCA Evaluation Service, Inc. (indicate report number)<br />

ICBO Evaluation Service, Inc. (indicate report number)<br />

<strong>National</strong> Evaluation Service, Inc. (indicate report number)<br />

SBCCI Public Safety Testing & Evaluation Service, Inc. (indicate report number)<br />

Other agencies (indicate agency & report identification number)<br />

12. LIMITATIONS AND/OR RESTRICTIONS<br />

13. SEE APPENDIX IF CHECKED X<br />

472


Wood Fiberboard <strong>Roof</strong> Insulation Board<br />

TREMCO INC.<br />

FIBERBASE<br />

HD<br />

HIGH<br />

TYPE II, GRADE 2<br />

ASPHALT<br />

COATED<br />

ASPHALT<br />

COATED<br />

NO<br />

X<br />

0.5 IN - 1.32<br />

0.781 IN - 2.06<br />

DIBOLL, TX<br />

517<br />

473


Appendix, Rigid Board Insulation<br />

AFM R-CONTROL BUILDING SYSTEMS foam core laminated <strong>to</strong> heavy black (nonasphaltic)<br />

glass-fiber reinforced felt facers. This product is<br />

Manufacturing locations for AFM-RControl Perform, suitable for all single-ply systems. Available in non-<br />

Con<strong>to</strong>ur Taper Tile and Perform Protect: AFP R- HCFC formulation.<br />

Control, 5250 N. Sherman St., Denver, CO 80216, ACFoam III also features the closed-cell foam core<br />

303/297-3844; AFP R-Control, 111 W. Fireclay Ave., integrally laminated <strong>to</strong> heavy coated glass facers. It<br />

Murray, UT 84107; AFP R-Control, 920 Kleppe Lane, is specifically designed for all single-ply, cold-applied<br />

Sparks, NV 89431, 800/444-9290; Allied Foam BUR, and cold-applied modified bitumen membrane<br />

Products, Inc. 1604 Athens Hwy., P.O. Drawer 695, systems. Do not use with hot-applied membranes.<br />

Gainesville, GA 30503, 800/533-2613; Branch River Available in non-HCFC formulation.<br />

Foam Plastics, Inc., 15 Thurber Blvd., Smithfield, RI ACFoam Supreme has a polyisocyanurate foam<br />

02917, 800/336-3626; Big Sky Insulations, Inc. 15 core with tri-laminate foil facers and provides THE<br />

Arden Drive, P.O. Box 838, Belgrade, MT 59714, highest R-value of all ACFoam products. Specifically<br />

800/766-3626; Con<strong>to</strong>ur Products, Inc., 1418 Cow designed for use with mechanically fastened and<br />

Palace Road, New<strong>to</strong>n KS 67114, 800/835-2161; IBS loose laid ballasted single-ply systems, ACFoam<br />

R-Control, 326 McGhee Road, Winchester, CVA Supreme should not be used directly with hot asphalt<br />

22603, 800/662-1065; Pacemaker Plastics Co., Inc. or <strong>to</strong>rch-applied systems. Available in non-HCFC<br />

126 New Pace Road, P.O. Box 279, Newcomers<strong>to</strong>wn, formulation.<br />

OH 43832, 800/44-2188; Poly-Foam Inc., 116 Pine ACFoam Composite consists of a polyisocyanurate<br />

Street South, Lester Prairie, MN 55354, 320/395- foam core bonded <strong>to</strong> 1/2-in. perlite on one side and a<br />

2551, 612/445-4089; Team R-Control, 4580 Airwest heavy black (nonasphaltic) glass-fiber reinforced felt<br />

Drive SE/P.O. Box 888691, Grand Rapids, MI 49588, on the other side. The perlite eliminates the need for<br />

800/356-5548; Therma Foam, Inc., P.O. Box 161128, cover boards or vented base sheets normally<br />

Fort Worth, TX 76161, 800/33-3626; Thermal Foams, recommended over foam insulation. The product is<br />

Inc. 2101 Kenmore Avenue, Buffalo, NY 14207, recommended for use with BUR, modified bitumen,<br />

800/873-6267; Wisconsin EPS, Inc., 90 Trowbridge and single-ply roofing systems. Available in non-<br />

Drive, P.O. Box 669, Fond du Lac, WI 54936-5377, HCFC formulation.<br />

800/236-5377. ACFoam Recover Board is part of the Atlas family of<br />

AFM R-Control Perform, Con<strong>to</strong>ur Taper Tile and thermally efficient polyiso foam board insulations. The<br />

Perform Protect roof isnulations have been fully foam core is covered on both sides with a heavy,<br />

tested for flame-spread classification. AFM R-Control strong coated fibrous facer. Available in non-HCFC<br />

EPS may be used in numerous assemblies. See formulation.<br />

listing in the following direc<strong>to</strong>ries: UL <strong>Roof</strong>ing Tapered ACFoam features a closed-cell<br />

Materials and Systems Direc<strong>to</strong>ry; UL Building polyisocyanurate foam core laminated <strong>to</strong> heavy black<br />

Materials Direc<strong>to</strong>ry; UL Fire Resistance Direc<strong>to</strong>ry; FM (nonasphaltic) glass-fiber reinforced felt facers. It is<br />

Building Materials Approval Guide. available in 4' x 4' panels with slopes of 1/8-in., 1/4-<br />

AFM-R Control EPS products are covered by a in., and 1/2-in./ft. Available in non-HCFC formulation.<br />

20 year, 100 percent R-value retention warranty. ACFoam Nail Base Insulation provides a base for<br />

AFM-R Control SIPs and SpecLam roof non-asphaltic shingles, tile, or metal roof panels and<br />

insulations have been fully tested for flame-spread may be applied over wood or steel decking.<br />

classification. AFM-R Control SIPs and SpecLam may Particularly suited for cathedral ceiling and log home<br />

be used in numerous assemblies. See listing in the applications, the product is a polyisocyanurate foam<br />

following direc<strong>to</strong>ries: UL <strong>Roof</strong>ing Materials and core that is faced with glass-fiber reinforced facers<br />

Systems Direc<strong>to</strong>ry; UL Building Materials Direc<strong>to</strong>ry; UL and bonded <strong>to</strong> 7/16-in. APA-rated OSB. Availalbe in<br />

Fire Resistance Direc<strong>to</strong>ry; FM Building Materials non-HCFC formulation.<br />

Approval Guide. AFM-R Control SIPs and SpecLam Vented-R is a polyiso insulation, laminated <strong>to</strong> OSB,<br />

are covered by a 20-year, 100 percent R-value constructed with ventilation spaces <strong>to</strong> reduce heat<br />

retention warranty.<br />

buildup. Available in non-HCFC formulation.<br />

Compliances: (Check with Atlas for specific<br />

ATLAS ROOFING CORPORATION<br />

applications for each product.) federal specifications<br />

HH-I-1972/GEN; HH-I-1972/2, Class 1; HH-I-<br />

ACFoam-II features a closed-cell polyisocyanurate<br />

474


Appendix, Rigid Board Insulation<br />

1972/1, Class 1; HH-I-1972/3; Metro-Dade County, FL<br />

No. 00-0298.04; Calif. State Insul. Qual. Standards &<br />

Title 25 Foam Flammability Criteria (License #TC<br />

1231); BOCA, ICBO, and SBCCI sections on foam<br />

insulation; FM Standard 4450/4470 approval for Class<br />

1 insulated roof deck construction; UL Standard 1256<br />

Classification: insulated metal deck construction<br />

assemblies, Construction Nos. 120 & 123; UL<br />

Standard 790 Classification: Class A with most roof<br />

membrane systems; UL Standard 263 Fire Resistance<br />

Classification (ACFoam-II/ACFoam Composite, Nail<br />

Base and Vented-R): some listings are P225, P230,<br />

P232, P259, P263, P508, P510, P514, P701, P710,<br />

P713, P717, P718, P719, P720, P722, P723, P724,<br />

P725, P728, P729, P730, P732, P801, P814, P815,<br />

P817, P818, P819, and P823. ASTM C1289-98, Type<br />

II; C1289-98, Type V; C1289-98, Type I, Class I;<br />

C1289-98, Type III. Meets Can/CGSB Standards,<br />

CCMC No. 12464-L, CCMC No. 12423-L, and CCMC<br />

No. 12422-R.<br />

BENCHMARK FOAM, INC.<br />

Perma-Foam EPS Insulation is available as flat or<br />

cus<strong>to</strong>m tapered in sheet sizes up <strong>to</strong> 36 inch X 48 inch<br />

x 216 inch.<br />

<strong>Roof</strong>ing systems described in the UL Fire<br />

Resistance Direc<strong>to</strong>ry approving Perma-Foam EPS<br />

include: P225, P230, P238, P246, P250, P251, P255,<br />

P259, P261, P262, P264, P269, P404, P410, P411,<br />

P501, P508, P509, P510, P511, P513, P514, P515,<br />

P519, P520, P701, P710, P713, P717, P719, P725,<br />

P734, P735, P801, P803, P814, P815, P818, P825,<br />

P902, P904, P907, P909, P912, P915, P919, P920,<br />

P921, P922, P923, P924, P925, P926, P928, P929,<br />

P930 and K902.<br />

<strong>Roof</strong>ing systems decribed in the UL <strong>Roof</strong>ing<br />

Materials and Systems Direc<strong>to</strong>ry approving Perma-<br />

Foam EPS include: Const. No. 219, 237,292, 374 and<br />

458.<br />

Benchmark Foam Inc. can also provide: Fac<strong>to</strong>ry<br />

Mutual Research Corporation aprpoval as an<br />

insulation component in Class 1 insulated steel and<br />

concrete roof constructions. See FMRC Standard<br />

4450 file 3D7A2.AM.<br />

Third part certificadtion by Resources,<br />

Applications, Designs and Controls, Inc. (RADCO)<br />

ensuring Perma-Foam insulation meets ASTM C-578<br />

as well as Smoke Development (ASTM E-84) and<br />

Flame Spread (ASTM E-84). See listing #1165.<br />

A 20-year 100 percent R-valule warranty upon<br />

request. Contact the roofing sales deparment at<br />

800/658-3444.<br />

BIG SKY INSULATIONS, INC.<br />

SnoFoam EPS: Approvals: ASTM C-578-87a, ICBO<br />

4169, UL P design numbers: P211, P225, P230,<br />

P231, P232, P238, P246, P250, P251, P254, P255,<br />

P261, P262, P410, P411, P508, P509, P510, P511,<br />

P513, P514, P515, P701, P710, P713, P715,<br />

P717,P801, P803, P814, P815, P817, P818, P902,<br />

P909, P912, P915, P919, P920, P921, P922, P923,<br />

J999, K901, K902, K903.<br />

CARLISLE SYNTEC INCORPORATED<br />

Sure-Seal EPS Insulation: UL Classified, FM<br />

Approved; Sure-Seal EPS Foam must be protected<br />

from: (a) temperatures greater than 160 F.; (b) oil,<br />

solvents, and other aliphatic or hydrocarbon<br />

substances that could degrade the foam. When used<br />

over coal tar roof membranes, the following<br />

procedures apply: (a) The coal tar roof membrane <strong>to</strong><br />

be covered must have been exposed in field surface<br />

environment for at least five years. (b) A minimum<br />

one-half inch butt-joined wood fiberboard separation<br />

barrier is installed prior <strong>to</strong> laying of the EPS. (c) The<br />

system design temperature does not<br />

exceed 130 F at the coal tar membrane/wood<br />

fiberboard interface. Protect from sunlight during<br />

s<strong>to</strong>rage. Review the Carlisle EPS Material Safety<br />

Data Sheet for complete safety information prior <strong>to</strong><br />

use.<br />

Thermapink 18/25/40; and Dow Dechmate,<br />

Plazamate and Recovermate; FM approved. Product<br />

should not be used in contact with chimneys, heater<br />

vents, steam pipes, or other surfaces where<br />

temperatures exceed 150 F. Product should be<br />

installed under a membrane applied <strong>to</strong> a substrate<br />

having an adequate fire rating as required by building<br />

codes, over metal or combustible deck. Separa<strong>to</strong>r<br />

sheet should be used where insulation may come in<br />

contact with PVC membrane if required by membrane<br />

manufacturer. Any material containing organic<br />

solvents should not be used in direct contact with<br />

polystyrene insulation unless previously evaluated.<br />

Protect from extended exposure of sunlight. The<br />

product will ignite if exposed <strong>to</strong> fire of sufficient heat<br />

and intensity, although it does contain a flame<br />

retardant additive <strong>to</strong> inhibit ignition from small fire<br />

sources.<br />

Polyisocyanurate HP, HP-H, HP-N, HP-W: UL<br />

Classified, FM Approved: Carlisle SynTec's<br />

Polyisocyanurate products are non-structural, non-<br />

475


Appendix, Rigid Board Insulation<br />

load bearing materials. They are not designed for hydrocarbons, chlorinated hydrocarbons, olefins,<br />

direct traffic usage unless adequately protected. All napthas, ke<strong>to</strong>nes, gasoline, fuel oil, and oil-based<br />

roof insulation should be kept dry and protected from paint. Maximum service temperature: 165 F, except<br />

the elements. No more insulation should be installed for Styrofoam brand Recovermate, which has a<br />

than can be covered in the same day. Isocyanurate maximum service temperature of 200 F. Light<br />

foam will burn if exposed <strong>to</strong> a flame of sufficient heat stability: When s<strong>to</strong>red outdoors for extended periods,<br />

and intensity. Contact Carlisle SynTec for advice on Styrofoam brand insulations should be shielded from<br />

the use of these products if there is any doubt the sunlight with an opaque, light-colored covering.<br />

concerning the proper product for the job, the proper Notice: Styrofoam brand insulation are combustible<br />

installation procedure or the proper code approvals. and should be s<strong>to</strong>red, handled, and used properly.<br />

HP Recovery Board: UL classified, FM approved. They should be installed with code-acceptable<br />

HP Recovery Board is a wood fiberboard thermal barriers or used in approved alternative<br />

underlayment for use with Carlisle roofing systems. All constructions. For more information, contact Dow<br />

roof insulation should be kept dry and protected from (800-441-4DOW).<br />

the elements. No more insulation should be installed<br />

than can be covered in the same day. Wood FIRESTONE BUILDING PRODUCTS, INC.<br />

fiberboard will burn if exposed <strong>to</strong> a flame of sufficient<br />

heat and intensity.<br />

ISO 95+: FM Class 1, 1-60 or 1-90. Fires<strong>to</strong>ne roof<br />

insulation products are non-structural, non-load<br />

THE DOW CHEMICAL COMPANY<br />

bearing materials. They are not designed for direct<br />

traffic usage unless adequately protected. All roof<br />

Blue Styrofoam Brand <strong>Roof</strong>mate Insulation, Blue insulation should be kept dry and protected from the<br />

Styrofoam Brand Plazamate Insulation, Blue elements. Asphalt mopping temperature must not<br />

Styrofoam Brand Square Edge Insulation, Blue exceed 450 F. No more insulation should be installed<br />

Styrofoam Brand Tongue & Groove Insulation, Blue than can be covered in the same day. Isocyanurate<br />

Styrofoam Brand Recovermate, Blue Styrofoam Brand foam will burn if exposed <strong>to</strong> a flame of sufficient heat<br />

Deckmate Insulation, Blue Styrofoam Brand Deckmate and intensity. Contact Fires<strong>to</strong>ne for advice on the<br />

Plus Insulation, Styrofoam Brand Insulations: UL use of these products if there is any doubt concerning<br />

Design Numbers: D2708, P225, P229, P230, P235, the proper product for the job, the proper installation<br />

P248, P250, P251, P254, P255, P259, P261, P404, procedure or the proper code approvals. Code<br />

P505, P507, P508, P510, P513, P514, P701, P710, approvals: Classified in UL designs, P225, P230,<br />

P711, P713, P714, P715, P717, P801, P803, P805, P232, P259, P263, P508, P510, P514, P701, P710,<br />

P811, P813, P814, P815, P817, P818, P902, P904, P717, P718, P719, P722, P723, P724, P725, P727,<br />

P907, P908, P909, P912, P915, P921, U326, U330, P728, P729, P730, P732, P801, P814, P815, P818,<br />

U460, U902, U912, P923. UL <strong>Roof</strong> Deck Construction P819, P823, P828; meets the requirements of ICBO<br />

Numbers: 1, 2, 3, 9, 14, 58, 87, 200, 237, 260, 276, Section 2602, SBCCI Section 2603, and BOCA<br />

380, 287, 440. Section 2603; Classified in UL deck construction 120<br />

Limitations and/or restrictions: Styrofoam Brand and 123.<br />

<strong>Roof</strong>ing Material insulation is designed for use above Composite <strong>Roof</strong> Insulation: UL Classification, FM<br />

waterproofing membranes in roof construction. Class 1, 1-60 or 1-90. Fires<strong>to</strong>ne's roof insulation<br />

Styrofoam Brand Plazamate and Styrofoam Brand products are non-structural, non-load bearing<br />

High Load 100 insulations are designed for use above materials. They are not designed for direct traffic<br />

waterproofing membranes in plaza and parking roof usage unless adequately protected. All roof<br />

deck construction and in other areas where high insulation should be kept dry and protected from the<br />

compressive strength insulation is required. elements.<br />

Styrofoam-Brand <strong>Roof</strong>ing Recovery Board, Styrofoam Asphalt mopping temperature must not exceed 450 F.<br />

brand Recovermate, and Styrofoam Deckmate and No more insulation should be installed than can be<br />

Deckmate Plus insulations are intended for use covered in the same day. Isocyanurate foam will burn<br />

beneath loose-laid and ballasted or if exposed <strong>to</strong> flame of sufficient heat and intensity.<br />

mechanically fastened sheet membranes Contact Fires<strong>to</strong>ne for advice on the use of these<br />

in roof construction. Styrofoam brand products if there is any doubt concerning the<br />

insulations have poor resistance <strong>to</strong> aromatic proper product for the job, the proper installation<br />

476


Appendix, Rigid Board Insulation<br />

procedure, or the proper code approvals. Classified<br />

in UL designs, P225, P230, P232, P508, P510, P514,<br />

P701, P710, P717, P718, P719, P723, P801, P815,<br />

P818, P828; BOCA 2603; meets the requirements of<br />

ICBO Section 2602, SBCCI Section 2603, and BOCA<br />

Section 2603; Classified in UL deck construction 120<br />

and 123.<br />

GAF MATERIALS CORPORATION<br />

GAFTEMP Permalite: UL Design Numbers:<br />

P001, P004, P201, P202, P203, P204, P206, P210,<br />

P211, P224, P225, P230, P232, P237, P238, P250,<br />

P254, P259, P263, P267, P404, P508, P514, P701,<br />

P708, P710, P713, P718, P801, P803, P805, P810,<br />

P814, P815, P817, P818, P819, P904, P909, P912,<br />

P915, S601, S702, S716, S717, S718.<br />

Limitations and Restrictions: GAFTEMP<br />

Permalite roof insulation should not be left exposed <strong>to</strong><br />

the weather. GAFTEMP Permalite insulation products<br />

are not recommended for continuous use at temperatures<br />

over 200 F. All insulation boards must be<br />

maintained in a dry condition prior <strong>to</strong> installation. For<br />

ambient temperatures below 40 degrees F, the use of<br />

hot bitumen application is not recommended due the<br />

rapid cooling of the bitumen. Direct <strong>to</strong>rching: GAF<br />

does not recommend that modified bitumen roof<br />

membranes be directly <strong>to</strong>rched <strong>to</strong> any insulation. A<br />

base sheet should be applied <strong>to</strong> the surface of the<br />

insulation and the <strong>to</strong>rchable membrane <strong>to</strong>rched <strong>to</strong> the<br />

base sheet.<br />

GAFTEMP Isotherm: GAFTEMP Isotherm roof<br />

insulation is a non-structural, non-loadbearing<br />

material. It is not designed for direct traffic usage<br />

unless adequately protected. GAFTEMP Isotherm<br />

roof insulation should be s<strong>to</strong>red dry and protected<br />

from the elements. No more insulation should be<br />

installed than can be completely covered with roofing<br />

on the same day. As unprotected urethane will burn,<br />

fire safety precautions should be observed wherever<br />

any isocyanurate products are used. GAFTEMP<br />

Isotherm is an insulation board made up of composite<br />

mat facers bonded <strong>to</strong> a core of isocyanurate foam.<br />

UL Design Numbers: P225, P230, P232, P259, P508,<br />

P510, P514, P710, P713, P715, P717, P718, P719,<br />

P720, P722, P723, P724, P727, P728, P729, P730,<br />

P732, P735, P738, P801, P815, P814, P818, P819,<br />

P823, 0827.<br />

Mechanical Fasteners: GAF recommends the use of<br />

GAFTITE Coated or Stainless Steel mechanical<br />

fasteners for the attachment of GAFTEMP roof<br />

insulation products <strong>to</strong> steel decks. The correct<br />

number and type, per the Fac<strong>to</strong>ry Mutual Approval<br />

Guide, should be used. Limitations: The values<br />

listed herein are typical, nominal values obtained<br />

under labora<strong>to</strong>ry conditions using industry-standard<br />

test methods. These values are subject <strong>to</strong> change at<br />

any time without notice.<br />

GP GYPSUM CORPORATION<br />

Compliances: UL P 224, 225, 227, 230, 232, 235,<br />

254, 257, 259, 266, 508, 510, 512, 514, 518, 701,<br />

713, 714, 717, 718, 719, 720, 722, 724, 725, 726,<br />

727, 728, 729, 730, 731, 732,733, 734, 735, 736,<br />

738, 740, 801, 803, 805, 811, 813, 814, 815, 818,<br />

819, 824, 825, 826, 828.<br />

HUEBERT FIBERBOARD, CO.<br />

HFB Insulation Board: Contact Huebert Fiberboard,<br />

Co. for any information on limitations or restrictions.<br />

JOHNS MANVILLE INTERNATIONAL<br />

Compliance: for square edge, 1-inch thick (24x48 in)<br />

boards for <strong>Roof</strong>-Ceiling Desing Nos. P001, P004,<br />

P206, P210, P211, P225, P230, P237, P238, P250,<br />

P254, P259, P267, P404, P508, P510, P514, P701,<br />

P710, P713, P718, P719, P720, P723, P732, P734,<br />

P735, P740, P801, P803, P805, P814, P818, P828.<br />

Plant locations: Bremen, IN; Belvidere, IL; Anderson,<br />

SC; Jacksonville, FL; Riverside, CA; Kent, WA;<br />

Hazle<strong>to</strong>n, PA; Corrwall, Ontario. Compliance for<br />

Types E’NRGY’2, “E’NRG’Y 2 Plus, Fesco-Foam,<br />

E’NRG’Y 2 Gypsum Composite for use in Design Nos.<br />

P225, P230, P259, P508, P510, P514, P519, P701,<br />

P710, P713, P717, P719, P720, P722, P723, P727,<br />

P728, P729, P730, P732, P741,P801, P814, P815,<br />

P818, P819, P823, P826.<br />

KOPPERS INDUSTRIES, INC.<br />

Refer <strong>to</strong> Koppers current literature for additional<br />

product information, application instructions, and<br />

technical details. Contact Koppers Sales and Service<br />

Center at 800-558-2706 for additional information<br />

and assistance.<br />

OWENS CORNING SPECIALTY & FOAM PRODUCTS<br />

General: Product should not be used in contact with<br />

chimneys, heater vents, steam pipes, or other<br />

surfaces where temperatures exceed 150 F.<br />

477


Appendix, Rigid Board Insulation<br />

Product should be applied <strong>to</strong> a substrate having an<br />

adequate fire rating as required by building codes,<br />

over metal or combustible deck. Some Thermapink<br />

applications may be applied directly over steel<br />

decking without the need for a thermal barrier, such<br />

as, gypsum board. Durapink Plus or a separa<strong>to</strong>r<br />

sheet should be used where insulation may come in<br />

contact with PVC membrane if required by membrane<br />

manufacturer. Any material containing organic<br />

solvents should not be used in direct contact with<br />

polystyrene insulation unless previously evaluated.<br />

Protect from extended exposure <strong>to</strong> sunlight. Product<br />

will ignite if exposed <strong>to</strong> fire of sufficient heat and<br />

intensity, although it does contain a flame retardant<br />

additive <strong>to</strong> inhibit ignition from small fire sources. For<br />

additional information, contact Owens Corning<br />

technical service (800) GET-PINK. Insulated <strong>Roof</strong><br />

Deck; UL <strong>Roof</strong> Deck Constr. 200, 219, 237, 289; UL<br />

Class A; See UL Fire Resistance direc<strong>to</strong>ry for below<br />

membrane design numbers P225, P230, P251, P513,<br />

P701, P801, P803, P814, P815, P902, P922, P923.<br />

Foamular 404: UL <strong>Roof</strong> Deck Constr. 1, 2, 3, 9,<br />

14, 27, 58, 87, 200; UL Class A; FM Class I & 60 or<br />

90 PSF, Insulated Steel <strong>Roof</strong> Deck; UL Design<br />

Numbers for inverted roof insulation: P225, P226,<br />

P229, P235, P248, P404, P505, P507, P701, P801,<br />

P803, P805, P811, P813, P902, P908, P909, P912,<br />

P915, P708.<br />

Thermapink 18/25/40/60: Thermapink products<br />

are used in all applications where the Foamular<br />

product of similar compressive strength is used.<br />

Thermapink has the added advantage of being listed<br />

for use by UL in <strong>Roof</strong> Deck construction #457, and as<br />

FM Class 2 roof construction, applied directly over<br />

steel roof decks without the use of a thermal barrier.<br />

<strong>Roof</strong>ing assemblies that require timed fire resistance<br />

may still require a gypsum board layer. See the UL<br />

<strong>Roof</strong>ing Materials and Systems Direc<strong>to</strong>ry and the FM<br />

Approval Guide for necessary details.<br />

Tapered Insulation: Tapered Thermapink 25, 40,<br />

and 60 are available for use in UL listed assemblies.<br />

See the appropriate listing direc<strong>to</strong>ry for complete<br />

details.<br />

Foamular 404 RB/Foamular 604 RB: For use in<br />

protected roof membrane assemblies and plaza decks<br />

when pavers are used as ballast or as a wearing<br />

surface. These are high-compressive-strength<br />

extruded polystyrene boards with drainage channels<br />

on the bot<strong>to</strong>m four edges, as well as channels cut in<br />

the <strong>to</strong>p of the board <strong>to</strong> separate the paver from the<br />

insulation.<br />

Foamular 400/Foamular 600: High-compressivestrength<br />

products able <strong>to</strong> withstand heavy loads<br />

without damage <strong>to</strong> the panels or deterioration of the<br />

insulating value.<br />

Durapink/Durapink FA, Durapink Plus: Specially<br />

designed for use in reroofing applications, either <strong>to</strong>tal<br />

tear-off or over existing BUR under single-ply<br />

mechanically fastened black EPDM without the need<br />

for any overlayment protection, ballast, or pavers<br />

and, in the case of Durapink Plus, directly under PVC.<br />

These products are not intended for use as a cover<br />

board in new roof construction or over added<br />

insulation in reroofing. Durapink FA can be used<br />

directly under fully adhered single-ply membranes,<br />

including black EPDM, by using water-based<br />

adhesives. Durapink and Durapink Plus provide<br />

excellent moisture resistance properties and a 25-psi<br />

compressive strength that endures foot traffic abuse<br />

and exposure <strong>to</strong> moisture; UL Class A and FM Class<br />

I-60 or 90 recover systems available with a wide<br />

variety of single-ply membranes. Durpink Plus has an<br />

18 psi compressive strength and excellent moisture<br />

resistance. See Owens Corning guide specification<br />

for detailed instructions.<br />

Insul-Drain: Designed <strong>to</strong> be installed on belowgrade<br />

foundation walls <strong>to</strong> the exterior side of the<br />

waterproofing membrane, the product has a network<br />

of precision-cut channels covered with filter fabric <strong>to</strong><br />

provide drainage, protection, and insulation for the<br />

foundation.<br />

PACEMAKER PLASTICS CO., INC.<br />

Expanded polystyrene roof insulation available flat or<br />

tapered in sheet sizes <strong>to</strong> 48-in. x 96-in. Products<br />

manufactured under quality control program are UL<br />

classified and can be used in place of other roof<br />

insulations in UL-classified assemblies. Fac<strong>to</strong>ry<br />

Mutual listed products; 20-year, 100 percent R-value<br />

warranty; laminated products; and Dow tapered<br />

insulation are also available.<br />

Chemfoam: Approvals: ASTM C-578-87a, ICBO<br />

4169, BOCA 8715, SBCCI 8735, UL R 12372, FM.<br />

UL P design numbers: P211, P225, P230, P232,<br />

P238, P246, P250, P251, P254, P261, P262, P410,<br />

P411, P508, P509, P510, P511, P514, P701, P710,<br />

P713, P715, P717, P803, P814, P815, P817, P818,<br />

P902, P909, P912, P915, P919, P920, P921, P922,<br />

P923, J999, K901, K902, K903.<br />

PACTIV BUILDING PRODUCTS<br />

Extruded Polystyrene <strong>Roof</strong>ing Recover Board (3/8-<br />

478


Appendix, Rigid Board Insulation<br />

in. thickness): available as 4 ft. x 50 ft. fanfolded<br />

bundle (Amocor-PB6), 4 ft. x 8 ft. sheets (Amocor<br />

Plygood-PG38), or 4 ft. x 9 ft. sheets (Amocor<br />

Plygood-PG39).<br />

Extruded Polystyrene Insulation Board: Available<br />

as Amofoam-CM (square edge), or Amofoam-SL<br />

(sidelap edge), Amofoam-DC (drainage channels).<br />

Amofoam available as 2 ft. x 8 ft. and 4 ft. x 8 ft. sizes.<br />

R-values and C-value for Amofoam are for Type IV.<br />

Underwriters Labora<strong>to</strong>ries, Inc. <strong>Roof</strong> deck<br />

construction numbers: Amofoam-CM, SL, 1, 2, 3, 9,<br />

14, 58, 87, 200.<br />

Limitations and/or restrictions: Amocor-PB6, Amocor-<br />

Plygood-PG38, and Amocor Plygood-PG39 <strong>Roof</strong>ing<br />

Recovery Boards are designed for use in<br />

mechanically fastened or loose-laid and ballasted<br />

single-ply roofing systems. Amofoam <strong>Roof</strong>ing<br />

Insulation Boards are designed for use in partially or<br />

fully adhered (1/2-in. wood fiberboard must be applied<br />

prior <strong>to</strong> membrane application), mechanically fastened<br />

or loose-laid and ballased, protected roof membrane<br />

assemblies, and tapered systems. All Amocor<br />

<strong>Roof</strong>ing Recovery and Amofoam Insulation Boards<br />

have poor resistance <strong>to</strong> fuel oil, oil-based paint,<br />

olefins, ke<strong>to</strong>nes, gasoline, chlorinated and aromatic<br />

hydrocarbons, and napthas. Foam plastic insulation<br />

will ignite if exposed <strong>to</strong> fire of sufficient heat and<br />

intensity. Protect foam insulation from exposure <strong>to</strong><br />

open flame or other ignition sources during shipment,<br />

s<strong>to</strong>rage, and installation. Obtain installation<br />

instructions from your supplier or Pactiv Building<br />

Products, 2100 RiverEdge Parkway, Suite 175,<br />

Atlanta, GA 30328.<br />

POLYFOAM PACKERS CORPORATION<br />

ThermoSafe EPS and EPS/Composite Board<br />

Insulation: Available in sizes up <strong>to</strong> 192 inches long by<br />

48.5 inches wide by 1/2-in <strong>to</strong> 40 inches thick. Boards<br />

between 2 and 8 inches thick are cut with 1/2-in. x<br />

1/2-in. thickness shiplap edges on all sides as<br />

standard (ThermoLock) and at no additional charge.<br />

Boards with square edges are available on request.<br />

Tapered boards (ThermoSafe DrainMaster), for<br />

slope-<strong>to</strong>-drain systems are available with complete<br />

shop drawings. Both flat and tapered insulation<br />

boards are available with fac<strong>to</strong>ry-laminated thermal<br />

barriers, facers, and coverboards (ThermoSafe-Plus)<br />

on one or two sides. Approvals: ASTM C-578;<br />

CABO 236, 238, 384 and 479; Fac<strong>to</strong>ry<br />

Mutual file no. 0V8A0.AC, 0V8A1.AC,<br />

0V8A2.AC; UL classification file R14213: tested<br />

under UL 790, 1256, and modified full-scale, ASTM<br />

E-108, and ASTM E-84 for flame spread and smoke,<br />

developed for use as designated in the UL Fire Resistance<br />

Direc<strong>to</strong>ry. UL Design numbers: P211, P225,<br />

P226, P230, P232, P235, P238, P254, P325, P404,<br />

P413, P508, P510, P514, P904, P909, P912, J925,<br />

J941, J970. UL Construction number 458, and<br />

Wisconsin DILHR number 960041-I.<br />

Quality Control: The ThermoSafe quality control<br />

program and UL classification meet or exceed<br />

requirements for building codes across the United<br />

States. ThermoSafe EPS roof insulation may be used<br />

with UL-approved (or equivalent) roof membrane<br />

systems and in place of other roof insulation in ULclassified<br />

assemblies.<br />

Installation: Follow guideline specifications in<br />

current ThermoSafe EPS roof insulation literature or<br />

contact Polyfoam Packers Corp., 3751 Sunset Ave.,<br />

Waukegan, IL 60087; (800) 800-0359.<br />

Warranty: 20 year for 100 percent R-value<br />

retention and dimensional stability when installed as<br />

specified. See current literature for details.<br />

R-MAX, INC.<br />

Thermaroof Plus: Uses: Designed for use under<br />

mechanically fastened or ballasted single-ply systems<br />

only over steel or non-combustible roof decks.<br />

Attachment: Use four FM-approved screw and plate<br />

fasteners per 4' x 8' sheet under mechanically<br />

fastened single-ply membranes. Consult membrane<br />

supplier for additional fastening requirements.<br />

Restrictions: Not for use under fully adhered singleplies,<br />

modified bitumen, or built-up roof membranes.<br />

Not <strong>to</strong> be used in exposed insulation systems.<br />

Multi-Max: Uses: Designed for use under<br />

mechanically fastened or ballasted single-ply, built-up<br />

roof, or modified bitumen membranes. Consult Rmax<br />

for applications. Attachment: Use one FM-approved<br />

screw and plate mechanical fastener per three or four<br />

square feet of insulation under built-up roof<br />

membranes. Use one FM-approved mechanical<br />

fastener per two square feet of insulation under<br />

modified bitumen systems.<br />

Multi-Max FA: Uses: Designed and suitable for<br />

use under built-up roofs or modified bitumen<br />

membrane systems. May be overlaid with perlite,<br />

wood fiberboard, or other suitable overlay <strong>to</strong> obtain<br />

membrane warranty from membrane manufacturer.<br />

Consult membrane manufacturer for requirements.<br />

Designed for use under all types of single-ply<br />

membranes: fully adhered, loose-laid and ballasted,<br />

and mechanically fastened. Attachment: Suitable<br />

479


Appendix, Rigid Board Insulation<br />

for attachment with hot bitumens according <strong>to</strong> NRCA<br />

specifications, or use FM-listed and approved<br />

mechanical screw-and-plate fasteners at recommended<br />

density according <strong>to</strong> Rmax, Inc.: typically,<br />

one per four square feet for BUR or solid mopped-in<br />

overlay. Use one per two square feet for fully<br />

adhered single-ply membranes.<br />

Thermaroof Composite: Uses: Designed for use<br />

under built-up roof or modified bitumen membranes.<br />

May be used under single-ply membranes when<br />

perlite layer specified over roof deck. May be applied<br />

<strong>to</strong> deck with perlite layer up <strong>to</strong> receive <strong>to</strong>rch applied<br />

modified bitumen or hot mopped built-up roof<br />

membrane. Attachment: Use one FM-approved<br />

screw and plate mechanical fastener per three or four<br />

square feet of insulation under built-up roof<br />

membranes. Use one FM-approved mechanical<br />

fastener per two square feet of insulation under<br />

modified bitumen systems.<br />

TEMPLE<br />

Fiber Base HD: FM-approved roof insulation for I-60<br />

and I-90 wind uplift rated systems as outlined in FM<br />

reports J.I. 2M3A2.AM and J.I. 1T6A2.AM. Approval<br />

under these reports includes 25/32” Fiber Base HD,<br />

effective June 1, 1999. FM allows Fiber Base HD<br />

wherever generic wood fiber insulation is specified.<br />

Fiber Base HD is available by special order as ULclassified<br />

product for the built-up roof covering<br />

material. See R11115(N) under TGFU in UL Building<br />

Materials direc<strong>to</strong>ry for specific details. Consult the<br />

roofing membrane manufacturer and the current FM<br />

approval guide for system compatibility and specific<br />

application instructions. Warning: Do not apply<br />

flame directly <strong>to</strong> Fiber Base HD. When applying<br />

modified bitumen membranes, a base sheet is<br />

required. Fiber Base HD may smolder or burn.<br />

Extinguish completely if ignited. Refer <strong>to</strong> Fiber Base<br />

HD application instructions for specific<br />

recommendations. Compliances: Industry Standard<br />

ANSI/AHA A 194.1 and ASTM C208.<br />

P717, P718, 719, P720, P722, P723, P724, P725,<br />

P728, P729, P730, P732, P801, P814, P815, P817,<br />

P818, P819, P823.<br />

Meets BOCA, ICBO, SBCCI and IBC sections on<br />

foam insulation.<br />

U.S. INTEC<br />

GAFTEMP Isotherm roof insulation is a non-structural,<br />

non-loadbearing material. It is not designed for direct<br />

traffic usage unless adequately protected. GAFTEMP<br />

Isotherm roof insulation should be s<strong>to</strong>red dry and<br />

protected from the elements. No more insulation<br />

should be installed than can be completely covered<br />

with roofing on the same day. As unprotected<br />

urethane will burn, fire safety precautions should be<br />

observed wherever any isocyanurate products are<br />

used. GAFTEMP Isotherm is an insulation board<br />

made up of composite mat facers bonded <strong>to</strong> a core of<br />

isocyanurate foam. UL Design Numbers: P225, P230,<br />

P232, P259, P508, P510, P514, P710, P713, P715,<br />

P717, P718, P719, P720, P722, P723, P724, P727,<br />

P728, P729, P730, P732, P735, P738, P801, P815,<br />

P814, P818, P819, P823, 0827.<br />

TREMCO<br />

Trisotech G: A rigid, closed cell polyisocyanurate<br />

foam core laminated on both sides <strong>to</strong> a black, glass<br />

fiber reinforced, non-asphaltic facer. A wood<br />

fiberboard overly is required over Trisotech G when<br />

the BURmastic Cold Process BUR Systems is<br />

specified.<br />

UL “P” Design Numbers for Trisotech G: P225,<br />

P230, P232, P263, P508, P510, P514, P710, P713,<br />

480


Section 3<br />

<strong>Roof</strong> Fasteners


Information on Section 3: <strong>Roof</strong> Fasteners<br />

General Information<br />

Section 3: <strong>Roof</strong> Fasteners in the 2001 edition of<br />

NRCA’s Low-Slope <strong>Roof</strong>ing Materials Guide<br />

provides a comprehensive listing of fastener<br />

products used in low-slope roofing. Such<br />

fasteners are typically used <strong>to</strong> attach rigid board<br />

insulation and/or single-ply membranes <strong>to</strong><br />

structural roof deck substrates.<br />

Information on roof fasteners is presented in the<br />

guide in four sections, based on the substrate in<strong>to</strong><br />

which fasteners will be attached. These four<br />

sections are as follows:<br />

C Steel decks<br />

C Wood decks<br />

C Concrete decks<br />

C Lightweight concrete, gypsum or<br />

cementitious wood fiber decks<br />

An index of the manufacturers included in Section<br />

3: <strong>Roof</strong> Fasteners and locations of their specific<br />

products within this section immediately follows<br />

this <strong>Roof</strong> Fasteners section.<br />

<strong>Roof</strong> Fastener Products: Steel Decks<br />

Specific listing information on roof fastener<br />

products used for steel roof decks is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Country of manufacture<br />

4. Used with<br />

5. Material type<br />

6. Coating type<br />

7. Shank type<br />

8. Point type<br />

9. Method of attachment<br />

10 Diameter, length, fastening range,<br />

penetration<br />

11. Head shape<br />

12. Head dimensions<br />

13. Plates<br />

14. Plate shape, dimensions and material<br />

15. Installation equipment<br />

16. Average pullout resistance<br />

17. Meets FM approval requirements as a<br />

component of a Class I steel roof<br />

deck<br />

18. Passes FM 4470 for corrosion resistance<br />

19. Acceptable by the following codes<br />

20. Warranty available from manufacturer<br />

<strong>Roof</strong> Fastener Products: Wood Decks<br />

Specific listing information on roof fastener products<br />

used for wood roof decks is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Country of manufacture<br />

4. Used with<br />

5. Material type<br />

6. Coating type<br />

7. Shank type<br />

8. Point type<br />

9. Method of attachment<br />

10. Diameter, length, fastening range,<br />

penetration<br />

11. Head shape<br />

12. Head dimensions<br />

13. Plates<br />

14. Plate shape, dimensions and material<br />

15. Installation equipment<br />

16. Average pullout resistance<br />

17. Meets FM approval requirements as a<br />

component of a Class I wood roof deck<br />

18. Acceptable by the following codes<br />

19. Warranty available from manufacturer<br />

<strong>Roof</strong> Fastener Products: Concrete Decks<br />

Specific listing information on roof fastener products<br />

used for concrete roof decks is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Country of manufacture<br />

4. Used with<br />

5. Material type<br />

6. Coating type<br />

7. Shank type<br />

8. Point type<br />

9. Method of attachment<br />

10. Diameter, length, fastening range,<br />

penetration<br />

11. Head shape<br />

12. Head dimensions<br />

13. Plates<br />

14. Plate shape, dimensions and material<br />

15. Installation equipment<br />

16. Average pullout resistance<br />

17. Meets FM approval requirements as a<br />

component of a Class I concrete roof<br />

deck<br />

18. Acceptable by the following codes<br />

19. Warranty available from manufacturer<br />

483


<strong>Roof</strong> Fastener Products: Lightweight<br />

Concrete, Gypsum or Cementitious Wood<br />

Fiber Decks<br />

Specific listing information on roof fastener products<br />

used for lightweight concrete, gypsum or<br />

cementitious wood fiber roof decks is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Country of manufacture<br />

4. Deck type<br />

5. Used with<br />

6. Material type<br />

7. Coating type<br />

8. Shank type<br />

9. Point type<br />

10. Method of attachment<br />

11. Diameter, length, fastening range,<br />

penetration<br />

12. Head shape<br />

13. Head dimensions<br />

14. Plates<br />

15. Plate shape, dimensions and material<br />

16. Installation equipment<br />

17. Average pullout resistance<br />

18. Acceptable by the following codes<br />

19. Warranty available from manufacturer<br />

Additional Information<br />

Users of the guide who are interested in additional<br />

information regarding roof fasteners are<br />

encouraged <strong>to</strong> refer <strong>to</strong> The NRCA <strong>Roof</strong>ing and<br />

Waterproofing Manual, Fifth Edition.<br />

484


Index <strong>to</strong> <strong>Roof</strong> Fasteners<br />

LTWT CONCRETE, GYPSUM, OR<br />

WOOD FIBER DECKS<br />

LTWT CONCRETE, GYPSUM, OR<br />

WOOD FIBER DECKS<br />

CONCRETE DECKS<br />

CONCRETE DECKS<br />

WOOD DECKS<br />

STEEL DECKS<br />

WOOD DECKS<br />

STEEL DECKS<br />

CARLISLE SYNTEC INCORPORATED 486 512 544 560 NATIONAL NAIL CORP. 524 551<br />

1285 Ritner Hwy. 2964 Clydon SW<br />

P.O. Box 7000 Grand Rapids, MI 49509<br />

Carlisle, PA 17013 800/746-5659<br />

717/245-7000 FAX 616/531-5970<br />

FAX 717/245-7053<br />

Web:<br />

Web: www,carlislesyntec.com OLYMPIC FASTENERS 499 526 552 573<br />

CELOTEX CORP. 488 514 545 562 P.O. Box 508<br />

4010 Boy Scout Blvd. 153 Bowles Road<br />

Tampa, FL 33607 Agawam, MA 01001<br />

813/873-4000 800/633-3800 or 413/789-0252<br />

FAX: FAX 413/789-1069<br />

Web:<br />

E-mail: info@olyfast.com<br />

CONSTRUCTION FASTENERS INC. 489 515 546 562 Web:<br />

DEKFAST PRODUCT GROUP POWERS RAWL, 502 527 553 575<br />

Spring & Van Reed Box 6326<br />

POWERS FASTENERS, INC.<br />

Wyomissing, PA 19610 New Rochelle, NY 10801<br />

610/376-5751 914/235-6300<br />

FAX 610/376-8551 FAX 914/576-6483<br />

E-mail: sales@constructionfasteners.com<br />

E-mail:<br />

Web: www.constructionfasteners.com<br />

Web: www.powers.com<br />

DURO-LAST INC. 491 517 547 563 SENCO PRODUCTS 529<br />

525 Morley Drive 8485 Broadwell Road<br />

Saginaw, MI 48601 Cincinnati, OH 45244<br />

800/248-0280 800/543-4596<br />

FAX 800/432-9331 FAX 800/543-3299<br />

E-mail: dlsagmi@consentric.com<br />

Web: www.senco.com<br />

Web: www.duro-last.com SFS STADLER INC. 503 530 555 576<br />

ES PRODUCTS INC. 517 563 5460 Wegman Drive<br />

280 Franklin Street P.O. Box 810 Valley City, OH 44280<br />

Bris<strong>to</strong>l, RI 02809 330/273-7171 or 800/648-6032<br />

401/253-8600 FAX 330/273-7181<br />

FAX 401/253-8896 E-mail:<br />

Web:<br />

Web:<br />

FIRESTONE BUILDING PRODUCTS 491 518 548 568 SIMPLEX NAILS & FASTENERS, INC. 533 556 578<br />

525 Congressional Blvd. 100 Petty Road, Suite A<br />

Carmel, IN 46032 Lawrenceville, GA 30043-4813<br />

800/428-4442 800/622-3354<br />

FAX 317/575-7100 FAX: 770/822-6822<br />

E-mail: fires<strong>to</strong>nebp.com<br />

E-mail: technical@www.simplexnails.com<br />

Web: www.fires<strong>to</strong>nebp.com<br />

Web:<br />

GAF MATERIALS CORP. 493 519 549 569 TREMCO INC. 508 579<br />

1361 Alps Road 3735 Green Road<br />

Wayne, NJ 07470 Beachwood, OH 44122<br />

973/628-3000 216/292-5000<br />

FAX 973/628-3451 FAX: 216/292-5076<br />

E-mail:<br />

E-mail: tremcoroofing.com<br />

Web: www.gaf.com<br />

Web:<br />

ITW BUILDEX 495 521 550 571 TRU-FAST CORPORATION 509 541 557 580<br />

1349 W. Bryn Mawr Ave. 02105 William County Road 12-C<br />

Itasca, IL 60143 Bryan, OH 43506<br />

800/284-5339 630/595-3500 800/443-9602<br />

FAX 630/595-6329 FAX: 419/636-1784<br />

E-mail:<br />

E-mail: tru-fast@bright.net<br />

Web:<br />

Web: www.trufast.com<br />

JOHNS MANVILLE INTERNATIONAL INC. 498 523 551 572 U.S. INTEC, INC. 542 559 581<br />

<strong>Roof</strong>ing Systems Group<br />

1361 Alps Road<br />

P.O. Box 5108 Wayne, NJ 07470<br />

Denver, CO 80217<br />

800/624-6832 (Tech Hotline)<br />

303/978-2000 800/231-4631<br />

FAX 303/978-3904<br />

FAX:<br />

Web: www.jm.com<br />

E-mail:<br />

485


<strong>Roof</strong> Fasteners: Steel Decks<br />

1 COMPANY NAME CARLISLE SYNTEC INCORPORATED CARLISLE SYNTEC INCORPORATED<br />

2. PRODUCT NAME HP FASTENER HP PURLIN FASTENER<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CARBON STEEL CARBON STEEL<br />

6. COATING TYPE EPOXY ELECTRODEPOSITION EPOXY ELECTRODEPOSITION<br />

7. SHANK TYPE SINGLE LEAD, BUTTRESS THREAD SINGLE LEAD "V" THREAD<br />

8. POINT TYPE MINI-DRILL POINT DRILL POINT<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (INCHES) / SHANK LENGTH (INCHES) /<br />

THICKNESS (INCHES) / DECK PENETRATION (INCHES)<br />

0.180 1-1/4 1/2 3/4 0.160 3 2 1<br />

0.180 1-3/4 1 3/4 0.160 4 3 1<br />

O.180 2-1/4 1-1/2 3/4 0.160 5 4 1<br />

0.180 2-3/4 2 3/4 0.160 6 5 1<br />

0.180 3-1/4 2-1/2 3/4 0.160 7 6 1<br />

0.180 3-3/4 3 3/4<br />

0.180 4-1/4 3-1/2 3/4<br />

0.180 5 4-1/4 3/4<br />

0.180 6 5-1/4 3/4<br />

0.180 7 6-1/4 3/4<br />

0.180 8 7-1/4 3/4<br />

0.180 9 8-1/4 3/4<br />

0.180 10 9-1/4 3/4<br />

0.180 11 10-1/4 3/4<br />

0.180 12 11-1/4 3/4<br />

0.180 13 12-1/4 3/4<br />

0.180 14 13-1/4 3/4<br />

0.180 15 14-1/4 3/4<br />

11. HEAD SHAPE WAFER HEX<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.105 0.140<br />

Diameter 0.43 0.430<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

SQUARE 2-7/8 GALVALUME LOCKING 2 GALVALUME W/PLAS<br />

(w/rounded corners) ROUND 2 PLASTIC<br />

ROUND 2 GALVALUME<br />

LOCKING 2 GALVALUME W/PLAS<br />

ROUND 2 PLASTIC<br />

ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

Other<br />

AUTOMATIC FASTENING TOOL<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

18 Gauge<br />

20 Gauge<br />

22 Gauge<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I STEEL ROOF DECK (yes/no) YES NO<br />

18. PASSES FM TEST PROCEDURE 4470 FOR CORROSION<br />

RESISTANCE (yes/no<br />

YES<br />

19. ACCEPTED BY THE FOLLOWING CODES FM<br />

20. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

21. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

486


<strong>Roof</strong> Fasteners: Steel Decks<br />

CARLISLE SYNTEC INCORPORATED CARLISLE SYNTEC INCORPORATED CARLISLE SYNTEC INCORPORATED<br />

HP-X FASTENER SURE FAST FASTENERS CARLISLE ASAP<br />

U.S. U.S. U.S.<br />

X<br />

X<br />

X<br />

CARBON STEEL CARBON STEEL CARBON STEEL<br />

EPOXY ELECTRODEPOSITION EPOXY ELECTRODEPOSITION EPOXY ELECTRO DEPOSITION<br />

SINGLE LEAD, BUTTRESS THREAD SINGLE LEAD, BUTTRESS THREAD SINGLE LEAD BUTTRESS THREAD<br />

MINI-DRILL POINT DRILL POINT 30 DEGREE SPADE POINT<br />

THREADED THREADED THREADED<br />

0.201 2 1-1/4 3/4 0.160 2-1/4 1-1/2 3/4 0.165 2-1/4 1-1/2 3/4<br />

0.201 3 2-1/4 3/4 0.160 2-7/8 2-1/8 3/4 0.165 2-7/8 2-1/8 3/4<br />

0.201 4 3-1/4 3/4 0.160 3-1/4 2-1/2 3/4 0.165 3-1/4 2-1/2 3/4<br />

0.201 5 4-1/4 3/4 0.160 3-3/4 3 3/4 0.165 3-3/4 3 3/4<br />

0.201 7 5-1/4 3/4 0.160 4-1/2 3-3/4 3/4 0.165 4-1/2 3-3/4 3/4<br />

0.201 7 6-1/4 3/4 0.160 5 4-1/4 3/4 0.165 5 4-1/4 3/4<br />

0.201 8 7-1/4 3/4 0.160 6 5-1/4 3/4 0.165 6 5-1/4 3/4<br />

0.201 10 9-1/4 3/4 0.160 7 6-1/4 3/4 0.165 7 6-1/4 3/4<br />

0.201 12 11-1/4 3/4 0.160 8 7-1/4 3/4 0.165 8 7-1/4 3/4<br />

0.201 14 13-1/4 3/4<br />

TRUSS #3 PHILLIPS<br />

TRUSS #3 PHILLIPS<br />

0.115 0.100 0.115<br />

0.435 0.425 0.435<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2-3/8 CARBON STEEL ROUND 3 GALVALUME ROUND 3 PLASTIC<br />

REQUIRED REQUIRED REQUIRED<br />

AUTOMATIC FASTENING TOOL<br />

AUTOMATIC FASTENING TOOL<br />

YES<br />

YES<br />

YES YES YES<br />

FM FM FM<br />

YES YES YES<br />

487


<strong>Roof</strong> Fasteners: Steel Decks<br />

1. COMPANY NAME CELOTEX CORPORATOIN CELOTEX CORPORATOIN<br />

2. PRODUCT NAME ANCHORBOND #12 ANCHORBOND #14<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HARDENED STEEL HARDENED CARBON STEEL<br />

6. COATING TYPE ORGANIC FLOUROPOLYMERS ORGANIC FLUOROPOLYMERS<br />

7. SHANK TYPE SPIRAL THREAD SPIRAL THREAD<br />

8. POINT TYPE SELF-DRILLING SELF-DRILLING<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (INCHES) / SHANK LENGTH (INCHES) /<br />

THICKNESS (INCHES) / DECK PENETRATION (INCHES)<br />

O.222 1-5/8 1-1/4 3/8 0.238 1-1/4 7/8 3/8<br />

0.222 2-1/4 1-7/8 3/8 0.238 1-5/8 1-1/4 3/8<br />

0.222 2-7/8 2-1/2 3/8 0.238 1-7/8 1-7/8 3/8<br />

0.222 3-3/4 3-3/8 3/8 0.238 2-7/8 2-1/2 3/8<br />

0.222 4-1/4 4-1/8 3/8 0.238 3-1/4 3-3/8 3/8<br />

0.222 5 4-5/8 3/8 0.238 4-1/2 4-1/8 3/8<br />

0.238 5 4-5/8 3/8<br />

0.238 6 5-5/8 3/8<br />

0.238 7 6-5/8 3/8<br />

0.238 8 7-5/8 3/8<br />

11. HEAD SHAPE #3 PHILLIPS FLAT TRUSS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.109 0.109<br />

Diameter 0.438 0.438<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

HEXAGONAL 2-7/8 GALVALUME HEXAGONAL 2-7/8 STAINLESS STEEL<br />

HEXAGONAL 2-7/8 GALVALUME<br />

HEXAGONAL 3 PLASTIC<br />

HEXAGONL 2 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL OPTIONAL<br />

Special Tool Needed (optional/required)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

18 Gauge 637 721<br />

20 Gauge 551 639<br />

22 Gauge 430 507<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I STEEL ROOF DECK (yes/no) YES YES<br />

18. PASSES FM TEST PROCEDURE 4470 FOR CORROSION<br />

RESISTANCE (yes/no YES YES<br />

19. ACCEPTED BY THE FOLLOWING CODES FM FM, UL<br />

20. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

21. SEE APPENDIX IF CHECKED X<br />

NA = not applicable<br />

488


<strong>Roof</strong> Fasteners: Steel Decks<br />

CELOTEX CORPORATION CELOTEX CORPORATION CONSTRUCTION FASTENERS, INC.<br />

ANCHORBOND #15 HEAVY DUTY ANCHORBOND #14 STAINLESS STEEEL DEKFAST #12<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

HARDENED CARBON STEEL STAINLESS STEEEL (#304) HARDENED CARBON STEEL<br />

ORGANIC FLUOROPOLYMERS ORGANIC FLUOROPOLYMERS ORGANIC<br />

SPIRAL THREAD SPIRAL THREAD SPIRAL THREAD<br />

SELF-DRILLING SELF-DRILLING SELF-DRILLING<br />

THREADED THREADED THREADED<br />

0.264 1-1/4 3/4 1/2 0.264 3 2 1 0.222 1-5/8 7/8 3/4<br />

0.264 2 1-1/2 1/2 0.264 4 3 1 0.222 2-1/4 1-1/2 3/4<br />

0.264 3 2-1/2 1/2 0.264 5 4 1 0.222 2-7/8 2-1/8 3/4<br />

0.264 4 3-1/2 1/2 0.264 6 5 1 0.222 3-1/4 2-1/2 3/4<br />

0.264 5 4-1/2 1/2 0.264 7 6 1 0.222 3-3/4 3 3/4<br />

0.264 6 5-1/2 1/2 0.264 8 7 1 0.222 4-1/2 3-3/4 3/4<br />

0.264 7 6-1/2 1/2 0.222 5 4-1/4 3/4<br />

0.264 8 7-1/2 1/2 0.222 6 5-1/4 3/4<br />

0.264 10 9-1/2 1/2 0.222 7 6-1/4 3/4<br />

0.264 12 11-1/2 1/2 0.222 8 7-1/4 3/4<br />

0.264 14 13-1/2 1/2<br />

0.264 16 15-1/2 1/2<br />

#3 PHILLIPS TRUSS #3 PHILLIPS TRUSS #3 PHILLIPS TRUSS & 1/4" HEX WASHER HEAD<br />

0.109 0.109 0.118 0.190<br />

0.438 0.438 0.448 0.448<br />

YES YES YES<br />

YES YES YES<br />

HEXAGONAL 2-7/8 STAINLESS STEEL HEXAGONAL 2-7/8 STAINLESS STEEL HEXAGONAL 2-7/8 GALVALUME<br />

HEXAGONAL 2-7/8 GALVALUME HEXAGONAL 2-7/8 GALVALUME HEXAGONAL 2-7/8 RECESS GALVLM<br />

HEXAGONL 2 GALVALUME HEXAGONAL 3 PLASTIC HEXAGONAL 3 PLASTIC<br />

HEXAGONL 2 GALVALUME ROUND 2 GALVALUME<br />

ROUND 3 PLASTIC<br />

ROUND 2 NYLON<br />

REQUIRED REQUIRED REQUIRED<br />

OPTIONAL OPTIONAL OPTIONAL<br />

735 790 756<br />

689 5550 561<br />

493 457 445<br />

YES YES YES<br />

YES YES YES<br />

FM FM FM, METRO-DATE COUNTY<br />

YES YES YES<br />

X<br />

489


<strong>Roof</strong> Fasteners: Steel Decks<br />

1. COMPANY NAME CONSTRUCTION FASTENERS INC. CONSTRUCTION FASTENERS, INC.<br />

2. PRODUCT NAME DEKFAST #14 DEKFAST #15 HI-STRENGTH<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HARDENED CARBON STEEL HARDENED CARBON STEEL<br />

6. COATING TYPE ORGANIC ORGANIC<br />

7. SHANK TYPE SPIRAL THREAD SPIRAL THREAD<br />

8. POINT TYPE SELF-DRILLING SELF-DRILLING<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (INCHES) / SHANK LENGTH (INCHES) /<br />

THICKNESS (INCHES) / DECK PENETRATION (INCHES)<br />

0.238 1-1/4 1/4 3/4 0.264 1-1/4 1/4 3/4<br />

0.238 1-5/8 7/8 3/4 0.264 2 1-1/4 3/4<br />

0.238 2-1/4 1-1/2 3/4 0.264 3 2-1/4 3/4<br />

0.238 2-7/8 2-1/8 3/4 0.264 4 3-1/4 3/4<br />

0.238 3-1/4 2-1/2 3/4 0.264 5 4-1/4 3/4<br />

0.238 3-3/4 3 3/4 0.264 6 5-1/4 3/4<br />

0.238 4-1/2 3-1/4 3/4 0.264 7 6-1/4 3/4<br />

0.238 5 4-1/4 3/4 0.264 8 7-1/4 3/4<br />

0.238 6 5-1/4 3/4 0.264 10 9-1/4 3/4<br />

0.238 7 6-1/4 3/4 0.264 12 11-1/4 3/4<br />

0.238 8 7-1/4 3/4 0.264 14 13-1/4 3/4<br />

0.238 10 9-1/4 3/4 0.264 16 15-1/4 3/4<br />

0.238 12 11-1/4 3/4 0.264 18 17-1/4 3/4<br />

0.264 20 19-1/4 3/4<br />

0.264 22 21-1/4 3/4<br />

0.264 24 23-1/4 3/4<br />

0.264 26 25-1/4 3/4<br />

11. HEAD SHAPE #3 PHILLIPS FLAT TRUSS #3 PHILLIPS TRUSS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.118 0.130<br />

Diameter 0.448 0.448<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

HEXAGONAL 2-7/8 GALVALUME HEXAGONAL 2-7/8 GALVALUME<br />

HEXAGONAL 3 PLASTIC ROUND 2 GALVALUME<br />

ROUND 2 GALVALUME ROUND 2-1/2 GALVALUME<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL OPTIONAL<br />

Special Tool Needed (optional/required)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

18 Gauge 900 1140<br />

20 Gauge 749 898<br />

22 Gauge 503 725<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I STEEL ROOF DECK (yes/no) YES YES<br />

18. PASSES FM TEST PROCEDURE 4470 FOR CORROSION<br />

RESISTANCE (yes/no YES YES<br />

19. ACCEPTED BY THE FOLLOWING CODES FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

20. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

21. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

490


<strong>Roof</strong> Fasteners: Steel Decks<br />

CONSTRUCTION FASTENERS, INC. DURO LAST INC. FIRESTONE BUILDING PRODUCTS<br />

#14 DEKFAST STAINLESS STEEL DURO LAST SCREWS #14 FIRESTONE ALL PURPOSE<br />

U.S. U.S. U.S.<br />

X X X<br />

X<br />

X X X<br />

STAINLESS STEEL (TRIMRITE) STEEL SAE 1022, HEAT TREATED<br />

NONE CLUOROCARBON EPOXY<br />

SPIRAL THREAD SPIRAL THREAD SPIRAL THREADED<br />

SELF-DRILLING SELF-DRILLING DRILL POINT<br />

THREADED THREADED THREADED<br />

0.235 1-1/2 3/4 3/4 0.190 1-3/4 1 1 0.235 1-1/4 1/2 3/4<br />

0.235 2 1-1/4 3/4 0.190 2 1-1/4 1 0.235 1-5/8 7/8 3/4<br />

0.235 3 2-1/4 3/4 0.190 2-1/2 1-3/4 1 0.235 2-1/4 1-1/2 3/4<br />

0.235 4 3-1/4 3/4 0.190 3 2-1/4 1 0.235 2-7/8 2-1/8 3/4<br />

0.235 5 4-1/4 3/4 0.190 3-1/2 2-3/4 1 0.235 3-1/4 2-1/2 3/4<br />

0.235 6 5-1/4 3/4 0.190 4 3-1/4 1 0.235 3-3/4 3 3/4<br />

0.235 7 6-1/4 3/4 0.190 4-1/2 3-3/4 1 0.235 4-1/2 3-3/4 3/4<br />

0.235 8 7-1/4 3/4 0.190 5 4-1/4 1 0.238 5 4-1/4 3/4<br />

0.235 10 9-1/4 3/4 0.190 5-1/2 4-3/4 1 0.235 6 5-1/4 3/4<br />

0.235 12 11-1/4 3/4 0.190 6 5-1/4 1 0.235 7 6-1/4 3/4<br />

0.190 7 6-1/4 1 0.235 8 7-1/4 3/4<br />

0.190 8 7-1/4 1<br />

0.190 9 8-1/4 1<br />

0.190 10 9-1/4 1<br />

0.190 11 10-1/4 1<br />

0.190 12 11-1/4 1<br />

#3 PHILLIPS TRUSS #3 PHILLIPS TRUSS ROUND MUSHROOM #3 PHILLIPS<br />

0.118 0.103 0.110<br />

0.440 0.438 0.437<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2 GALVALUME ROUND (SEAM) 2 POLYCARBONATE HEX (insulation) 2-7/8 GALVALUME<br />

ROUND 3 GALVALUME ROUND (SEAM) 2 GALVALUME ROUND (in-seam) 2 GALVALUME<br />

ROUND (INSULATION) 3 PLASTIC ROUND (in-seam) 2-3/8 GALVALUME<br />

ROUND (INSULATION) 3 GALVALUME<br />

REQUIRED REQUIRED REQUIRED<br />

OPTIONAL OPTIONAL OPTIONAL<br />

830 900<br />

656 517 650<br />

472 450<br />

YES YES YES<br />

YES YES YES<br />

FM, METRO-DADE COUNTY METRO DADE, FM, ICBO, BOCA, SBCCI, UL FM, ICBO, UL, SBCCI<br />

YES YES YES<br />

491


<strong>Roof</strong> Fasteners: Steel Decks<br />

1. COMPANY NAME FIRESTONE BUILDING PRODUCTS FIRESTONE BUILDING PRODUCTS<br />

2. PRODUCT NAME PRE-ASSEMBLED FASTENER FIRESTONE HEAVY DUTY<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

Single-Ply Membranes<br />

X<br />

5. MATERIAL TYPE C-1022, HEAT-TREATED STEEL SAE 1022, HEAT TREATED<br />

6. COATING TYPE EPOXY EPOXY<br />

7. SHANK TYPE SPIRAL THREADED BUTTRESS THREAD<br />

8. POINT TYPE DRILL POINT DRILL POINT<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (INCHES) / SHANK LENGTH (INCHES) /<br />

THICKNESS (INCHES) / DECK PENETRATION (INCHES)<br />

0.196 2-1/4 1-1/2 3/4 0.264 1-1/4 1/2 3/4<br />

0.196 2-7/8 2-1/8 3/4 0.264 2 1-1/4 3/4<br />

0.196 3-1/4 2-1/2 3/4 0.264 3 2-1/4 3/4<br />

0.196 3-3/4 3 3/4 0.264 4 3-1/4 3/4<br />

0.196 4-1/2 3-3/4 3/4 0.264 5 4-1/4 3/4<br />

0.196 5 4-1/4 3/4 0.264 6 5-1/4 3/4<br />

0.196 6 5-1/4 3/4 0.264 7 6-1/4 3/4<br />

0.196 7 6-1/4 3/4 0.264 8 7-1/4 3/4<br />

0.196 8 7-1/4 3/4 0.264 10 9-1/4 3/4<br />

0.264 12 11-1/4 3/4<br />

0.264 14 13-1/4 3/4<br />

11. HEAD SHAPE #3 PHILLIPS TRUSS ROUND MUSHROOM #3 PHILLIPS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.100 0.110<br />

Diameter 0.433 0.437<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

HEX 2-7/8 GALAVLUME HEX (insulation) 2-7/8 GALVALUME<br />

ROUND (in-seam) 2 GALVALUME<br />

ROUND (in-seam) 2-3/8 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL OPTIONAL<br />

Special Tool Needed (optional/required)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

18 Gauge 558 950<br />

20 Gauge 456 730<br />

22 Gauge 452 690<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I STEEL ROOF DECK (yes/no) YES YES<br />

18. PASSES FM TEST PROCEDURE 4470 FOR CORROSION<br />

RESISTANCE (yes/no YES YES<br />

19. ACCEPTED BY THE FOLLOWING CODES FM, ICBO, UL, SBCCI FM, ICBO, UL, SBCCI<br />

20. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

21. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

492


<strong>Roof</strong> Fasteners: Steel Decks<br />

GAF MATERIALS CORPORATION GAF MATERIALS CORPORATION GAF MATERIALS CORPORATION<br />

GAFTITE #12-11/EVERGUARD EGIN GAFTITE #14-10/EVERGUARD EGHD GAFTITE #12-11/EVERGUARD EGIN<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

STAINLESS, SPECIAL, 400-SERIES BLEND HARDENED CARBON STEEL HARDENED CARBON STEEL<br />

CR-10 FLUOROCARON CR-1O FLUOROCARBON CR-10 FLUOROCARBON<br />

THREADED THREADED THREADED<br />

PINCH, SELF-DRILLING PINCH, SELF-DRILLILNG OR TAPEX PINCH, SELF-DRILLING, GIMLET, OR TAPEX<br />

THREADED THREADED THREADED<br />

0.172 1-5/8 1-3/8 1/2 0.190 1-1/4 3/4 1/2 0.160 1-5/8 1-1/8 1/2<br />

0.172 2-1/4 1-3/4 1/2 0.190 1-3/4 1-1/4 1/2 0.160 2-1/4 1-3/4 1/2<br />

0.172 2-1/8 2-3/8 1/2 0.190 2 1-1/2 1/2 0.160 2-7/8 2-3/8 1/2<br />

0.172 3-1/4 2-3/4 1/2 0.190 3 2-1/2 1/2 0.160 3-1/4 2-3/4 1/2<br />

0.172 4-1/2 4 1/2 0.190 4 3-1/2 1/2 0.160 4-1/2 4 1/2<br />

0.172 5 4-1/2 1/2 0.190 5 4-1/2 1/2 0.160 5 4-1/2 1/2<br />

0.172 6 5-1/2 1/2 0.190 6 5-1/2 1/2 0.160 6 5-1/2 1/2<br />

0.172 7 6-1/2 1/2 0.190 7 6-1/2 1/2 0.160 8 7-1/2 1/2<br />

0.172 8 7-1/2 1/2 0.190 8 7-1/2 1/2<br />

0.190 9 8-1/2 1/2<br />

0.190 10 9-1/2 1/2<br />

0.190 11 10-1/2 1/2<br />

0.190 12 11-1/2 1/2<br />

0.190 14 13-1/2 1/2<br />

0.190 16 15-1/2 1/2<br />

0.190 18 17-1/2 1/2<br />

0.190 20 19-1/2 1/2<br />

0.190 21 20-1/2 1/2<br />

0.190 22 21-1/2 1/2<br />

0.190 24 23-1/2 1/2<br />

ROUND TRUSS, #3 PHILLIPS ROUND TRUSS, #3 PHILLIPS ROUND TRUSS, #3 PHILLIPS<br />

0.110 0.110 0.110<br />

0.435 0.435 0.435<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2 STAINLESS STEEL ROUND 2 STEEL ROUND 2 STEEL<br />

ROUND 3 STAINLESS STEEL ROUND 2 PLASTIC ROUND 2 PLASTIC<br />

ROUND 2 STEEL ROUND 3 STEEL ROUND 3 STEEL<br />

ROUND 2 PLASTIC ROUND 3 PLASTIC ROUND 2 STAINLESS STEEL<br />

ROUND 3 STEEL ROUND 2 STAINLESS STEEL ROUND 3 STAINLESS STEEL<br />

ROUND 3 PLASTIC ROUND 3 STAINLESS STEEL ROUND 3 PLASTIC<br />

REQUIRED REQUIRED REQUIRED<br />

OPTIONAL OPTIONAL OPTIONAL<br />

540 585 540<br />

501 535 501<br />

456 505 436<br />

YES YES YES<br />

YES YES YES<br />

FM, UL, ICBO, METRO-DADE COUNTY FM, UL, ICBO, METRO-DADE COUNTY FM, U, ICBO, METRO-DADE COUNTY<br />

YES<br />

YES<br />

493


<strong>Roof</strong> Fasteners: Steel Decks<br />

1. COMPANY NAME GAF MATERIALS CORPORATION GAF MATERIALS CORPORATION<br />

2. PRODUCT NAME GAFTITE #14-10/EVERGUARD EGHD EVERGUARD EGX<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE STAINLESS STEEL, SPECIAL 400-SERIES BLEND HARDENED CARBON STEEL<br />

6. COATING TYPE CR-10-FLUOROCARBON CR-10 FLUOROCARBON<br />

7. SHANK TYPE THREADED THREADED<br />

8. POINT TYPE PINCH, SELF-DRILLING DOUBLE-EDGE DRILL<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (INCHES) / SHANK LENGTH (INCHES) /<br />

THICKNESS (INCHES) / DECK PENETRATION (INCHES)<br />

0.201 1-1/4 3/4 1/2 0.201 2 1-1/4 1/4<br />

0.201 1-3/4 1-1/4 1/2 0.201 3 2-1/4 1/4<br />

0.201 2 1-1/2 1/2 0.201 4 3-1/4 1/4<br />

0.201 3 2-1/2 1/2 0.201 5 4-1/4 1/4<br />

0.201 4 3-1/2 1/2 0.201 6 5-1/4 1/4<br />

0.201 5 4-1/2 1/2 0.201 7 6-1/4 1/4<br />

0.201 6 5-1/2 1/2 0.201 8 7-1/4 1/4<br />

0.201 7 6-1/2 1/2 0.201 10 9-1/4 1/4<br />

0.201 8 7-1/2 1/2 0.201 12 11-1/4 1/4<br />

0.201 9 8-1/2 1/2 0.201 14 13-1/4 1/4<br />

0.201 10 9-1/2 1/2 0.201 16 15-1/4 1/4<br />

0.201 12 11-1/2 1/2<br />

0.201 14 13-1/2 1/2<br />

0.201 16 15-1/2 1/2<br />

0.201 18 17-1/2 1/2<br />

0.201 20 19-1/2 1/2<br />

0.201 21 20-1/2 1/2<br />

0.201 22 21-1/2 1/2<br />

0.201 24 23-1/2 1/2<br />

11. HEAD SHAPE ROUND TRUSS, #3 PHILLIPS ROUND TRUSS, #3 PHILLIPS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.108 0.110<br />

Diameter 0.435 0.435<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 2 STAINLESS STEEL ROUND 2-3/8 STEEL<br />

ROUND 3 STAINLESS STEEL<br />

ROUND 2 STAINLESS<br />

ROUND 2 PLASTIC<br />

ROUND 3 STAINLESS<br />

ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL OPTIONAL<br />

Special Tool Needed (optional/required)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

18 Gauge 585 1114<br />

20 Gauge 535 937<br />

22 Gauge 505 718<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I STEEL ROOF DECK (yes/no) YES YES<br />

18. PASSES FM TEST PROCEDURE 4470 FOR CORROSION<br />

RESISTANCE (yes/no YES YES<br />

19. ACCEPTED BY THE FOLLOWING CODES FM, UL, ICBO, METRO-DADE COUNTY FM, UL<br />

20. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

21. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

494


<strong>Roof</strong> Fasteners: Steel Decks<br />

GAF MATERIALS CORP/N.T.B. FASTENING SYSTEM ITW BUILDEX ITW BUILDEX<br />

N-C HEXTRA ROOF GRIP<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

NYLON HARDENED CARBON STEEL HARDENED CARBON STEEL<br />

NA CLIMASEAL OR SPEX SPEX<br />

SPIRAL THREAD MODIFIED BUTTRESS THREAD MODIFIED BUTTRESS THREAD<br />

X-POINT<br />

X-POINT<br />

THREADED, SPIN WELD THREADED THREADED<br />

0.250 4 3-3/4 1/2 0.215 1-5/8 7/8 3/4 0.215 1-5/8 7/8 3/4<br />

0.250 6 5-3/4 1/2 0.215 2-1/4 1-1/2 3/4 0.215 2-1/4 1-1/2 3/4<br />

0.250 8 7-3/4 1/2 0.215 2-7/8 2-1/8 3/4 0.215 2-7/8 2-1/8 3/4<br />

0.250 10 9-3/4 1/2 0.215 3-1/4 2-1/2 3/4 0.215 3-1/4 2-1/2 3/4<br />

0.250 12 11-3/4 1/2 0.215 3-3/4 3 3/4 0.215 3-3/4 3 3/4<br />

0.215 4-3/8 3-5/8 3/4 0.215 4-3/8 3-5/8 3/4<br />

0.215 5 4-1/4 3/4 0.215 5 4-1/4 3/4<br />

0.215 6 5-1/4 3/4 0.215 6 5-1/4 3/4<br />

0.215 6 5-1/4 3/4 0.215 6 5-1/4 3/4<br />

0.215 7 6-1/4 3/4 0.215 7 6-1/4 3/4<br />

0.215 8 7-1/4 3/4 0.215 8 7-1/4 3/4<br />

DOUBLE HEX 1/4-IN. HEX HEAD #3 PHILLIPS PAN-HEAD<br />

0.100 0.180 0.118<br />

1.0 0.392 0.448<br />

YES YES YES<br />

YES YES YES<br />

ROUND W/SPIKES 2 NYLON SQUARE 3 X 3 GALVALUME SQUARE 3 X 3 GALVALUME<br />

ROUND W/SPIKES 3 CARBON STEEL GEARLOCK 3 POLYOLEFIN GEARLOCK 3 POLYOLEFIN<br />

ROUND 2 GALVALUME ROUND 2 GALVALUME<br />

REQUIRED REQUIRED REQUIRED<br />

ACCUDRIVE XL PLUS (OPTIONAL)<br />

ACCUDRIVE XL PLUS (OPTIONAL)<br />

500+ 894 894<br />

500+ 565 656<br />

500+ 488 488<br />

YES YES YES<br />

NA YES YES<br />

FM FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

YES YES YES<br />

495


<strong>Roof</strong> Fasteners: Steel Decks<br />

1. COMPANY NAME ITW BUILDEX ITW BUILDEX<br />

2. PRODUCT NAME ROOF GRIP PLUS ACCUTRAC FASTENER<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

Single-Ply Membranes<br />

5. MATERIAL TYPE CARBON STEEL HARDENED CARBON STEEL<br />

6. COATING TYPE CLIMASEAL SPEX OR CLIMASEAL<br />

7. SHANK TYPE MODIFIED BUTTRESS THREAD MODIFIED BUTTRESS THREAD<br />

8. POINT TYPE X-POINT X-POINT<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (INCHES) / SHANK LENGTH (INCHES) /<br />

THICKNESS (INCHES) / DECK PENETRATION (INCHES)<br />

0.215 2-1/4 1-1/2 3/4 0.215 1-5/8 7/8 3/4<br />

0.215 2-7/8 2-1/8 3/4 0.215 2-1/4 1-1/2 3/4<br />

0.215 3-1/4 2-1/2 3/4 0.215 2-7/8 2-1/8 3/4<br />

0.215 3-3/4 3 3/4 0.215 3-1/4 2-1/2 3/4<br />

0.215 4-3/8 3-5/8 3/4 0.215 3-3/4 3 3/4<br />

0.215 5 4-1/4 3/4 0.215 4-3/8 3-5/8 3/4<br />

0.215 6 5-1/4 3/4 0.215 5 4-1/4 3/4<br />

0.215 7 6-1/4 3/4 0.215 6 5-1/4 3/4<br />

0.215 8 7-1/4 3/4<br />

11. HEAD SHAPE #3 PHILLIPS PAN HEAD 1/4-IN. HEX HEAD OR #3 PHILLIPS PAN HEAD<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.180 0.180<br />

Diameter 0.392 0.392<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 3 GALVALUME SQUARE 3 X 3 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required) ACCUFAST STAND-UP TOOL (OPTIONAL) ACCUTRAC I, II, OR III (REQUIRED)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

18 Gauge 894 894<br />

20 Gauge 656 656<br />

22 Gauge 488 488<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I STEEL ROOF DECK (yes/no) YES YES<br />

18. PASSES FM TEST PROCEDURE 4470 FOR CORROSION<br />

RESISTANCE (yes/no YES YES<br />

19. ACCEPTED BY THE FOLLOWING CODES FM FM, METRO-DADE COUNTY<br />

20. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

21. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

496


<strong>Roof</strong> Fasteners: Steel Decks<br />

ITW BUILDEX ITW BUILDEX ITW BUILDEX<br />

#14 ROOF GRIP #15 ROOF GRIP HEXTRA PLUS<br />

U.S. U.S. U.S.<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

HARDENED CARBON STEEL HARDENED CARBON STEEL CARBON STEEL<br />

CLIMASEAL CLIMASEAL CLIMASEAL<br />

MODIFIED STANDARD THREAD STANDARD THREAD MODIFIED BUTRESS THREAD<br />

X-POINT DRILL POINT X-POINT<br />

THREADED THREADED THREADED<br />

0.252 1-1/2 3/4 3/4 0.260 1-1/4 1/2 3/4 0.215 2-1/4 1-1/2 3/4<br />

0.252 2 1-1/4 3/4 0.260 2 1-1/4 3/4 0.215 2-7/8 2-1/8 3/4<br />

0.252 3 2-1/4 3/4 0.260 3 1-3/4 3/4 0.215 3-1/4 2-1/2 3/4<br />

0.252 4 3-1/4 3/4 0.260 4 3-1/4 3/4 0.215 3-3/4 3 3/4<br />

0.252 5 4-1/4 3/4 0.260 5 4-1/4 3/4 0.215 4-3/8 3-5/8 3/4<br />

0.252 6 5-1/4 3/4 0.260 6 5-1/4 3/4 0.215 5 4-1/4 3/4<br />

0.252 7 6-1/4 3/4 0.260 7 6-1/4 3/4 0.215 6 5-1/4 3/4<br />

0.252 8 7-1/4 3/4 0.260 8 7-1/4 3/4 0.215 7 6-1/4 3/4<br />

0.260 10 9-1/4 3/4 0.215 8 7-1/4 3/4<br />

0.260 12 11-1/4 3/4<br />

0.260 14 13-1/4 3/4<br />

0.260 16 15-1/4 3/4<br />

#3 PHILLIPS PAN HEAD #3 PHILLIPS PAN HEAD 1/4-IN. HEX HEAD<br />

0.118 0.118 0.180<br />

0.448 0.448 0.392<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2 GALVALUME ROUND 2 GALVALUME ROUND 3 GALVALUME<br />

SQUARE 3 GALVALUME SQUARE 3 GALVALUME<br />

ROUND 3 PLASTIC<br />

REQUIRED<br />

ACCUDRIVE XL PLUS (OPTIONAL)<br />

REQUIRED<br />

ACCUFACT STAND-UP TOOL (OPTIONAL)<br />

971 894<br />

686 656<br />

560 488<br />

YES<br />

YES<br />

FM<br />

YES<br />

YES<br />

YES<br />

FM<br />

YES<br />

X<br />

497


<strong>Roof</strong> Fasteners: Steel Decks<br />

1. COMPANY NAME JOHNS MANVILLE INTERNATIONAL, INC. JOHNS MANVILLE INTERNATIONAL, INC.<br />

2. PRODUCT NAME ULTRAFEST/HEX HEAD ULTRAGRIP/PHILLIPS HEAD #12<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

Single-Ply Membranes<br />

5. MATERIAL TYPE HARDENED CARBON STEEL HARDENED CARBON STEEL<br />

6. COATING TYPE CLIMASEAL SPEX<br />

7. SHANK TYPE MODIFIED BUTTRESS THREAD MODIFIED BUTTRESS THREAD<br />

8. POINT TYPE SELF-DRILLING X-POINT SELF-DRILLING X-POINT<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (INCHES) / SHANK LENGTH (INCHES) /<br />

THICKNESS (INCHES) / DECK PENETRATION (INCHES)<br />

0.215 1-5/8 1-1/8 1/2 0.215 1-5/8 1-1/8 1/2<br />

0.215 2-1/4 1-3/4 1/2 0.215 2-1/4 1-3/4 1/2<br />

0.215 2-7/8 2-3/8 1/2 0.215 2-7/8 2-3/8 1/2<br />

0.215 3-1/4 2-3/4 1/2 0.215 3-1/4 2-3/4 1/2<br />

0.215 3-3/4 3-1/4 1/2 0.215 3-3/4 3-1/4 1/2<br />

0.215 4-3/8 3-7/8 1/2 0.215 4-3/8 3-7/8 1/2<br />

0.215 5 4-1/2 1/2 0.215 5 4-1/2 1/2<br />

0.215 6 5-1/2 1/2 0.215 6 5-1/2 1/2<br />

0.215 7 6-1/2 1/2 0.215 7 6-1/2 1/2<br />

0.215 8 7-1/2 1/2 0.215 8 7-1/2 1/2<br />

11. HEAD SHAPE 1-4-IN. HEX HEAD #3 PHILLIPS HEAD<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.180 0.118<br />

Diameter 0.392 0.448<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

SQUARE 3 X 3 CARBON STEEL W/ SQUARE 3 X 3 CARBON STEEL W/<br />

GALVALUME GALVALUME<br />

MANVILLE ROUND<br />

MANVILLE ROUND<br />

LOCKING PLATE 3 POLYOLEFIN LOCKING PLATE 3 POLYOLEFIN<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL (ACCUDRIVE XL) OPTIONAL (ACCUDRIVE XL)<br />

Special Tool Needed (optional/required)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

18 Gauge 674 674<br />

20 Gauge 502 502<br />

22 Gauge 425 425<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I STEEL ROOF DECK (yes/no) YES YES<br />

18. PASSES FM TEST PROCEDURE 4470 FOR CORROSION<br />

RESISTANCE (yes/no YES YES<br />

19. ACCEPTED BY THE FOLLOWING CODES FM, UL, ICBO, METRO-DADE COUNTY FM, UL, ICBO, METRO-DADE COUNTY<br />

20. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

21. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

498


<strong>Roof</strong> Fasteners: Steel Decks<br />

JOHNS MANVILLE INTERNATIONAL INC. JOHNS MANVILLE INTERNATIONAL, INC. OLYMPIC MANUFACTURING GROUP / N.T.B.<br />

HIGHLOAD FASTENER HIGHLOAD ASAP N-C<br />

U.S. U.S. U.S.<br />

X<br />

X<br />

X X X<br />

HARDENED CARBON STEEL HARDENED CARBON STEEL NYLON<br />

CLIMASEAL CR-10 NA<br />

MODIFIED BUTTRESS THREAD MODIFIED BUTTRESS THREAD SPIRAL THREAD<br />

SELF-DRILLING X-POINT<br />

SPADE POINT<br />

THREADED THREADED EXPANSION NUT<br />

0.20 1-1/4 3/4 1/2 0.16 2-1/4 1-3/4 1/2 0.250 4 3-3/4 1 /2<br />

0.20 2 1-1/2 1/2 0.16 2-7/8 2-3/8 1/2 0.250 6 5-3/4 1/2<br />

0.20 2 2-1/2 1/2 0.16 3-1/4 2-3/4 1/2 0.250 8 7-3/ 4 1/2<br />

0.20 4 3-1/2 1/2 0.16 3-3/4 3-1/4 1/2 0.250 10 9-3/4 1/2<br />

0.20 5 4-1/2 1/2 0.16 4-1/2 4 1/2 0.250 12 11-3/4 1/2<br />

0.20 6 5-1/2 1/2 0.16 5 4-1/2 1/2<br />

0.20 7 6-1/2 1/2 0.16 6 5-1/2 1/2<br />

0.20 8 7-1/2 1/2 0.16 7 6-1/2 1/2<br />

0.20 10 9-1/2 1/2 0.16 8 7-1/2 1/2<br />

0.20 12 11-1/2 1/2<br />

#3 PHILLIPS HEAD #3 PHILLIPS HEAD DOUBLE HEX<br />

0.100<br />

0.435 0.435 1.0 AND 2.0<br />

YES YES YES<br />

YES YES YES<br />

ROUND PREM CARBON STEEL W/ ROUND 2 NYLON (LOCKING) ROUND W/SPIKES 2 STEEL<br />

LOCKING PLATE 2 POLYOLEFIN (LOCKING) ROUND W/SPIKES 3 STEEL<br />

MANVILLE ROUND<br />

LOCKING PLATE 3 POLYOLEFIN<br />

REQUIRED REQUIRED REQUIRED<br />

850 575 500+<br />

675 525 500+<br />

500 475 500+<br />

YES YES YES<br />

YES YES NA<br />

FM FM FM<br />

YES YES YES<br />

X<br />

X<br />

499


<strong>Roof</strong> Fasteners: Steel Decks<br />

1. COMPANY NAME OLYMPLIC MANUFACTURING GROUP OLYMPLIC MANUFACTURING GROUP<br />

2. PRODUCT NAME OLYMPIC FASTENER STD #12 (C-STEEL) OLYMPIC FASTENER #12-11 (S-STEEL)<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HARDENED CARBON STEEL STAINLESS STEEL, SPECIAL 400-SERIES BLEND<br />

6. COATING TYPE CR-10 CR-10<br />

7. SHANK TYPE THREADED THREADED<br />

8. POINT TYPE PINCH, SELF-DRILLING, GILMENT OR TAPEX PINCH, SELF-DRILLING<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (INCHES) / SHANK LENGTH (INCHES) /<br />

THICKNESS (INCHES) / DECK PENETRATION (INCHES)<br />

0.160 1-5/8 1-1/8 3/4 0.168 1-5/8 1-1/8 3/4<br />

0.160 2-1/4 1-3/4 3/4 0.168 2-1/4 1-3/4 3/4<br />

0.160 2-7/8 2-3/8 3/4 0.168 2-7/8 2-3/8 3/4<br />

0.160 3-1/4 2-3/4 3/4 0.168 3-1/4 2-3/4 3/4<br />

0.160 3-3/4 3-1/4 3/4 0.168 3-3/4 3-1/4 3/4<br />

0.160 4-1/2 4 3/4 0.168 4-1/2 4 3/4<br />

0.160 5 4-1/2 3/4 0.168 5 4-1/2 3/4<br />

0.160 6 5-1/2 3/4 0.168 6 5-1/2 3/4<br />

0.160 7 6-1/2 3/4 0.168 7 6-1/2 3/4<br />

0.160 8 7-1/2 3/4 0.168 8 7-1/2 3/4<br />

11. HEAD SHAPE ROUND TRUSS, #3 PHILLIPS, OR HEX HEAD ROUND TRUSS, #3 PHILLIPS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.110 0.110<br />

Diameter 0.435 0.4.35<br />

13. PLATES<br />

Required (yes/no)<br />

YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 2 STEEL ROUND 2 STAINLESS STEEL<br />

ROUND 2 PLASTIC ROUND 3 STAINLESS STEEL<br />

ROUND 3 STEEL ROUND 2 STEEL<br />

ROUND 3 PLASTIC ROUND 2 PLASTIC<br />

ROUND 3-1/2 STEEL ROUND 3 STEEL<br />

ROUND 2 STAINLESS STEEL ROUND 3 PLASTIC<br />

ROUND 3 STAINLESS STEEL ROUND 3-1/ 2 STEEL<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL OPTIONAL<br />

Special Tool Needed (optional/required)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

18 Gauge 540 540<br />

20 Gauge 501 501<br />

22 Gauge 456 456<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I STEEL ROOF DECK (yes/no) YES YES<br />

18. PASSES FM TEST PROCEDURE 4470 FOR CORROSION<br />

RESISTANCE (yes/no YES YES<br />

19. ACCEPTED BY THE FOLLOWING CODES FM, UL, ICBO, METRO-DADE COUNTY FM, UL, ICBO, METRO-DADE COUNTY<br />

20. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

21. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

500


<strong>Roof</strong> Fasteners: Steel Decks<br />

OLYMPIC MANUFACTURING GROUP OLYMPIC MANUFACTURING GROUP OLYMPIC MANUFACTURING GROUP<br />

OLYMPIC FASTENER HD #14 (C-STEEL) OLYMPIC FASTENER HD #14 (S-STEEL) XHD<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

HARDENED CARBON STEEL STAINLESS STEEL, SPECIAL 400-SERIES BLEND HARDENED CARBON STEEL<br />

CR-10 CR-10 CR-10<br />

THREADED THREADED THREADED<br />

PINCH, SELF-DRILLING, OR TAPEX PINCH, SELF-DRILLING DOUBLE EDGE DRILL<br />

THREADED THREADED THREADED<br />

0.190 1-1/4 3/4 3/4 0.201 1-1/4 3/4 3/4 0.202 2 1-1/4 3/4<br />

0.190 1-3/4 1-1/4 3/4 0.201 1-3/4 1-1/4 3/4 0.202 3 2-1/4 3/4<br />

0.190 2 1-1/2 3/4 0.201 2 1-1/2 3/4 0.202 4 3-1/4 3/4<br />

0.190 3 2-1/2 3/4 0.201 3 2-1/2 3/4 0.202 5 4-1/4 3/4<br />

0.190 4 3-1/2 3/4 0.201 4 3-1/2 3/4 0.202 6 5-1/4 3/4<br />

0.190 5 4-1/2 3/4 0.201 5 4-1/2 3/4 0.202 7 6-1/4 3/4<br />

0.190 6 5-1/2 3/4 0.201 6 5-1/2 3/4 0.202 8 7-1/4 3/4<br />

0.190 7 6-1/2 3/4 0.201 7 6-1/2 3/4 0.202 9 8-1/4 3/4<br />

0.190 8 7-1/2 3/4 0.201 8 7-1/2 3/4 0.202 10 9-1/4 3/4<br />

0.190 9 8-1/2 3/4 0.201 9 8-1/2 3/4 0.202 11 10-1/4 3/4<br />

0.190 10 9-1/2 3/4 0.201 10 9-1/2 3/4 0.202 12 11-1/4 3/4<br />

0.190 11 10-1/2 3/4 0.201 12 11-1/2 3/4<br />

0.190 12 11-1/2 3/4 0.201 14 13-1/2 3/4<br />

0.190 14 13-1/2 3/4 0.201 16 15-1/2 3/4<br />

0.190 16 15-1/2 3/4 0.201 17 16-1/2 3/4<br />

0.190 17 16-1/2 3/4 0.201 18 17-1/2 3/4<br />

0.201 18 17-1/2 3/4 0.201 20 19-1/2 3/4<br />

0.201 20 19-1/2 3/4 0.201 21 20-1/2 3/4<br />

0.201 21 20-1/2 3/4 0.201 21 20-1/2 3/4<br />

0.201 22 21-1/2 3/4 0.201 22 21-1/2 3/4<br />

0.201 24 23-1/2 3/4 0.201 24 23-1/2 3/4<br />

ROUND TRUSS, #3 PHILLIPS ROUND TRUSS, #3 PHILLIPS ROUND TRUSS #3 PHILLIPS<br />

0.110 0.108 0.110<br />

0.435 0.435 0.435<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2 STEEL ROUND 2 STAINLESS STEEL ROUND 2 STEEL<br />

ROUND 2 PLASTIC ROUND 3 STAINLESS STEEL ROUND 3 STEEL<br />

ROUND 3 STEEL ROUND 2 STEEL ROUND 2-3/8 STEEL<br />

ROUND 3 PLASTIC ROUND 2 PLASTIC ROUND 2 PLASTIC<br />

ROUND 3-1/2 STEEL ROUND 3 STEEL ROUND 2-3/8 PLASTIC<br />

ROUND 2 STAINLESS STEEL ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

ROUND 3 STAINLESS STEEL ROUND 3-1/ 2 STEEL ROUND 2 STAINLESS STEEL<br />

ROUND 3 STAINLESS STEEL<br />

REQUIRED REQUIRED REQUIRED<br />

OPTIONAL OPTIONAL OPTIONAL<br />

OPTIONAL<br />

585 585 895<br />

535 535 835<br />

505 505 750<br />

YES YES YES<br />

YES YES YES<br />

FM, UL, ICBO, METRO-DADE COUNTY FM, UL, ICBO, METRO-DADE COUNTY FM, UL , ICBO, DADE COUNTY<br />

YES YES YES<br />

501


<strong>Roof</strong> Fasteners: Steel Decks<br />

1. COMPANY NAME POWERS FASTENERS, INC. POWERS FASTENERS, INC.<br />

2. PRODUCT NAME POWER RAWL SPEED-LOCK TOGGLE POWERS RAWL #12 DECK SCREW<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CARBON STEEL & STAINLESS STEEL CASE HARDENED CARBON STEEL<br />

6. COATING TYPE PERMA-SEAL FLUOROPOLYME (on carbon steel bolt only) PERMA-SEAL FLUOROPOLYMER<br />

7. SHANK TYPE ANNULAR THREAD SPIRAL THREAD<br />

8. POINT TYPE NA DRILL TYPE<br />

9. METHOD OF ATTACHMENT CLAMPING THREADED<br />

10. SHANK DIAMETER (INCHES) / SHANK LENGTH (INCHES) /<br />

THICKNESS (INCHES) / DECK PENETRATION (INCHES)<br />

0.250 5 3-1/2 1-1/2 0.226 1-5/8 7/8 3/4<br />

0.250 6 4-1/2 1-1/2 0.226 2-1/4 1-1/2 3/4<br />

0.250 7 5-1/2 1-1/2 0.226 2-7/8 2-1/8 3/4<br />

0.250 8 6-1/2 1-1/2 0.226 3-1/4 2-1/2 3/4<br />

0.250 9 7-1/2 1-1/2 0.226 3-3/4 3 3/4<br />

0.250 10 8-1/2 1-1/2 0.226 4-1/2 3-3/4 3/4<br />

0.250 12 10-1/2 1-1/2 0.266 5 4-1/4 3/4<br />

0.250 14 12-1/2 1-1/2 0.266 6 5-1/4 3/4<br />

0.266 7 6-1/4 3/4<br />

0.266 8 7-1/4 3/4<br />

11. HEAD SHAPE PHILLIPS FLAT HEAD #3 RECESS PHILLIPS TRUSS HEAD #3 RECESS WASHER / 1/4-IN HEX HEAD<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.042 0.130 , 0.140<br />

Diameter 0.426 0.448, 0.385<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 3 GALVALUME ROUND BARBED 2 GALVALUME<br />

ROUND 3 GALVALUME<br />

ROUND 3 STAINLESS STEEL<br />

ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) OPTIONAL REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL STAND UP TOOL (OPTIONAL)<br />

Special Tool Needed (optional/required)<br />

APPROPRIATE DRILL & BIT FOR DRILLING THROUGH DECK (REQUIRED)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

18 Gauge 725<br />

20 Gauge 655<br />

22 Gauge 975 550<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I STEEL ROOF DECK (yes/no) YES YES<br />

18. PASSES FM TEST PROCEDURE 4470 FOR CORROSION<br />

RESISTANCE (yes/no YES YES<br />

19. ACCEPTED BY THE FOLLOWING CODES FM FM<br />

20. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

21. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

502


<strong>Roof</strong> Fasteners: Steel Decks<br />

POWERS FASTENERS, INC. POWERS FASTENERS, INC. SFS STADLER INC.<br />

POWERS RAWL #14 DECK SCREW POWERS RAWL #15 DECK SCREW ISOFAST IF2-M<br />

U.S. U.S. U,S.<br />

X X X<br />

X X X<br />

X X X<br />

CASE HARDENED CARBON STEEL CASE HARDENED CARBON STEEL CARBON STEEL<br />

PERMA-SEAL FLUOROPOLYMER PERMA-SEAL FLUOROPOLYMER TUFF-TITE II<br />

SPIRAL THREAD SPIRAL THREAD THREADED<br />

DRILL TYPE RICOH "S" POINT SELF-DRILLING 2-FLUTE DRILL POINT<br />

THREADED THREADED THREADED<br />

0.238 1-5/8 7/8 3/4 0.264 1-1/4 1/2 3/4 0.189 2 1-1/2 1/2<br />

0.238 2-1/4 1-1/2 3/4 0.264 2 1-1/4 3/4 0.189 2-1/4 1-3/4 1/2<br />

0.238 2-7/8 2-1/8 3/4 0.264 3 2-1/4 3/4 0.189 2-3/4 2-1/4 1/2<br />

0.238 3-3/4 3 3/4 0.264 4 3-1/4 3/4 0.189 3-1/8 2-5/8 1/2<br />

0.238 4-1/2 3-3/4 3/4 0.264 5 4-1/4 3/4 0.189 3-7/8 3-3/8 1/2<br />

0.238 5 4-1/4 3/4 0.264 6 5-1/4 3/4 0.189 4-3/4 4-1/4 1/2<br />

0.238 6 5-1/4 3/4 0.264 7 6-1/4 3/4 0.189 5-1/2 4-3/4 1/2<br />

0.238 7 6-1/4 3/4 0.264 8 7-1/4 3/4 0.189 6-1/4 5-1/2 1/2<br />

0.238 8 7-1/4 3/4 0.264 10 9-1/4 3/4<br />

0.238 10 9-1/4 3/4 0.264 12 11-1/4 3/4<br />

0.238 12 11-1/4 3/4 0.264 14 13-1/4 3/4<br />

0.264 16 15-1/4 3/4<br />

PHILLIPS FLAT TRUSS HEAD #3 RECESS PHILLIPS TRUSS HEAD #3 RECESS 5/16 HEX HEAD<br />

0.118 0.130 0.156<br />

0.448 0.448 0.406<br />

YES YES YES<br />

YES YES YES<br />

ROUND BARBED 2 GALVALUME ROUND BARBED 2 GALVALUME OVAL 3-1/4 X 1-5/8 GALVALUME<br />

ROUND 3 GALVALUME ROUND 3 GALVALUME SQUARE 2-3/4 X 2-3/4 GALVALUME<br />

ROUND 3 STAINLESS STEEL ROUND 3 STAINLESS STEEL DOMED COVEX 3-1/4 X 1-5/8 GALVALUME<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

REQUIRED REQUIRED REQUIRED<br />

STAND UP TOOL (OPTIONAL) STAND UP TOOL (OPTIONAL) REQUIRED<br />

REQUIRED<br />

735 800 --<br />

630 690 552<br />

505 485 505<br />

YES YES YES<br />

YES YES YES<br />

FM FM FM, METRO-DADE COUNTY<br />

YES YES YES<br />

X<br />

503


<strong>Roof</strong> Fasteners: Steel Decks<br />

1. COMPANY NAME SFS STADLER INC. SFS STADLER INC.<br />

2. PRODUCT NAME ISOFAST IF2-C-M ISOFAST IF-2-S<br />

3. COUNTRY OF MANUFACTURE U.S. SWITZERLAND<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CARBON STEEL 300 SERIES STAINLESS STEEL<br />

6. COATING TYPE TUFF-TITE II<br />

7. SHANK TYPE THREADED THREADED<br />

8. POINT TYPE SELF-DRILLING 2 FLUTE DRILL POINT SELF-DRILLING 2 FLUTE DRILL POINT<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (INCHES) / SHANK LENGTH (INCHES) /<br />

THICKNESS (INCHES) / DECK PENETRATION (INCHES)<br />

0.189 2-1/8 1-5/8 1/2 0.189 2 1-1/2 1/2<br />

0.189 2-1/4 1-3/48 1/2 0.189 3-1/8 2-5/8 1/2<br />

0.189 2-3/4 2-1/4 1/2 0.189 3-7/8 3-3/8 1/2<br />

0.189 3-1/8 2-5/8 1/2 0.189 4-3/4 4-1/4 1/2<br />

0.189 3-7/8 3-3/8 1/2 0.189 5-1/2 4-3/4 1/2<br />

0.189 4-3/4 4-1/4 1/2 0.189 6-1/4 5-1/2 1/2<br />

0.189 5-1/2 4-3/4 1/2<br />

0.189 6-1/4 5-1/2 1/2<br />

11. HEAD SHAPE #2 POSI-DRIVE COUNTERSUNK 8 mm HEX HEAD<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.156 0.156<br />

Diameter 0.406 0.406<br />

13. PLATES<br />

Required (yes/no)<br />

YES<br />

Available From Manufacturer (yes/no)<br />

YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

OVAL 3-1/4 X 1-5/8 GALVALUME OVAL 3-1/4 X 1-5/8 GALVALUME<br />

SQUARE 2-3/4 X 2-3/4 GALVALUME SQUARE 2-3/4 X 2-3/4 GALVALUME<br />

DOMED COVEX 3-1/4 X 1-5/8 GALVALUME DOMED COVEX 3-1/4 X 1-5/8 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) REQUIRED OPTIONAL<br />

Special Tool Needed (optional/required) REQUIRED OPTIONAL<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

18 Gauge -- --<br />

20 Gauge 552 552<br />

22 Gauge 505 451<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I STEEL ROOF DECK (yes/no) YES YES<br />

18. PASSES FM TEST PROCEDURE 4470 FOR CORROSION<br />

RESISTANCE (yes/no<br />

YES<br />

19. ACCEPTED BY THE FOLLOWING CODES FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

20. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

21. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

504


<strong>Roof</strong> Fasteners: Steel Decks<br />

SFS STADLER INC. SFS STADLER INC. SFS STADLER INC.<br />

SYSTEM METAL ES INSUL-FIXX #12-11 INSUL-FIXX #14-10<br />

U.S. U.S. U.S.<br />

X X X<br />

X<br />

X<br />

X<br />

HARDENED STEEL HARDENED STEEL HARDENED STEEL<br />

TUFF TITE II TUFF-TITE II TUFF-TITE II<br />

SPIRAL THREAD SPIRAL THREAD THREADED<br />

SELF-DRILLING AND FLUTE DRILL POINT DRILL POINT DRILL POINT<br />

THREADED THREADED THREADED<br />

0.189 2 1-1/2 1/2 0.172 1-5/8 1-3/8 1/2 0.190 1-1/4 3/4 1/2<br />

0.189 2-1/4 1-3/4 1/2 0.172 2-1/4 1-3/4 1/2 0.190 2 1-1/2 1/2<br />

0.189 2-3/4 2-1/4 1/2 0.172 2-7/8 2-3/8 1/2 0.190 3 2-1/2 1/2<br />

0.189 3-1/8 2-5/8 1/2 0.172 3-1/4 2-3/4 1/2 0.190 4 3-1/2 1/2<br />

0.189 3-7/8 3-3/8 1/2 0.172 4-1/2 4 1/2 0.190 5 4-1/2 1/2<br />

0.189 4-3/4 4-1/4 1/2 0.172 5 4-1/2 1/2 0.190 6 5-1/2 1/2<br />

0.189 5-1/2 4-3/4 1/2 0.172 6 5-1/2 1/2 0.190 7 6-1/2 1/2<br />

0.189 6-1/4 5-1/2 1/2 0.172 7 6-1/2 1/2 0.190 8 7-1/2 1/2<br />

0.172 8 7-1/2 1/2 0.190 10 9-1/2 1/2<br />

0.190 12 11-1/2 1/2<br />

0.190 14 13-1/2 1/2<br />

0.190 16 15-1/2 1/2<br />

0.190 18 17-1/2 1/2<br />

0.190 20 19-1/2 1/2<br />

0.190 22 21-1/2 1/2<br />

0.190 24 23-1/2 1/2<br />

0.190 26 25-1/2 1/2<br />

8mm HEX HEAD ROUND WITH #3 PHILLIPS TRUSS ROUND WITH #3 PHILLIPS TRUSS<br />

0.156 0.103 0.103<br />

0.406 0.425 0.425<br />

YES YES YES<br />

YES YES YES<br />

ROUND 3 GALVALUME ROUND 3 POLYETHYLENE ROUND 3 POLYETHYLENE<br />

ROUND 3 GALVALUME ROUND 3 GALVALUME<br />

ROUND 2 GALVALUME<br />

ROUND 2 NYLON WITH GLASS<br />

REQUIRED REQUIRED REQUIRED<br />

OPTIONAL<br />

OPTIONAL<br />

-- 660 690<br />

552 575 610<br />

451 481 535<br />

YES YES YES<br />

YES YES YES<br />

FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

YES YES YES<br />

X<br />

X<br />

505


<strong>Roof</strong> Fasteners: Steel Decks<br />

1. COMPANY NAME SFS STADLER INC. SFS STADLER INC.<br />

2. PRODUCT NAME SYSTEM ES I $14-10 SYSTEM ES I #12-11<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HARDENED STEEL HARDENED STEEL<br />

6. COATING TYPE TRUFF-TITE II TUFF-TITE II<br />

7. SHANK TYPE THREADED SPIRAL THREAD<br />

8. POINT TYPE DRILL POINT DRILL POINT<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (INCHES) / SHANK LENGTH (INCHES) /<br />

THICKNESS (INCHES) / DECK PENETRATION (INCHES)<br />

0.190 2 1-3/8 1/2 0.172 2-1/4 1-3/4 1/2<br />

0.190 3 2-1/2 1/2 0.172 2-7/8 2-3/8 1/2<br />

0.190 4 3-1/2 1/2 0.172 3-1/4 2-3/4 1/2<br />

0.190 5 4-1/2 1/2 0.172 4-1/2 4 1/2<br />

0.190 6 5-1/2 1/2 0.172 5 4-1/2 1/2<br />

0.190 7 6-1/2 1/2 0.172 6 5-1/2 1/2<br />

0.190 8 7-1/2 1/2 0.172 7 6-1/2 1/2<br />

0.190 10 9-1/2 1/2 0.172 8 7-1/2 1/2<br />

0.190 12 11-1/2 1/2<br />

11. HEAD SHAPE ROUND WITH #3 PHILLIPS TRUSS ROUND WITH #3 PHILLIPS TRUSS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.103 0.103<br />

Diameter 0.425 0.425<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 3 POLYETHYLENE ROUND 3 POLYETHYLENE<br />

ROUND 3 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL OPTIONAL<br />

Special Tool Needed (optional/required) OPTIONAL OPTIONAL<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

18 Gauge 690 650<br />

20 Gauge 610 575<br />

22 Gauge 535 481<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I STEEL ROOF DECK (yes/no) YES YES<br />

18. PASSES FM TEST PROCEDURE 4470 FOR CORROSION<br />

RESISTANCE (yes/no YES YES<br />

19. ACCEPTED BY THE FOLLOWING CODES FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

20. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

21. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

506


<strong>Roof</strong> Fasteners: Steel Decks<br />

SFS STADLER INC. SFS STADLER INC. SFS STADLER<br />

SYSTEM ES I #14-10 EXTRA LOAD FASTENER HD TPR-THE PEEL RIVET<br />

U.S. U.S. ISRAEL<br />

X X X<br />

X X X<br />

X X X<br />

HARDENED STEEL HARDENED STEEL ALUMINUM ALLOY<br />

TUFF-TITE II TUFF-TITE II NA<br />

THREADED THREADED HOLLOW RIVET BODY<br />

DRILL POINT DRILL POINT PIERCING MANDREL<br />

THREADED THREADED CLAMPING<br />

0.190 2 1-3/8 1/2 0.205 1-1/4 3/4 1/2 0.250 1-1/4 1/4 1<br />

0.190 3 2-1/2 1/2 0.205 2 1-1/2 1/2 0.250 2 1 1<br />

0.190 4 3-1/2 1/2 0.205 3 2-1/2 1/2 0.250 3 2 1<br />

0.190 5 4-1/2 1/2 0.205 4 3-1/2 1/2 0.250 4 3 1<br />

0.190 6 5-1/2 1/2 0.205 5 4-1/2 1/2 0.250 5 4 1<br />

0.190 7 6-1/2 1/2 0.205 6 5-1/2 1/2 0.250 6 5 1<br />

0.190 8 7-1/2 1/2 0.205 8 7-1/2 1/2 0.250 7 6 1<br />

0.190 10 9-1/2 1/2 0.205 10 9-1/2 1/2 0.250 8 7 1<br />

0.190 12 11-1/2 1/2 0.205 12 11-1/2 1/2 0.250 9 8 1<br />

0.205 14 13-1/2 1/2 0.250 10 9 1<br />

0.205 16 15-1/2 1/2<br />

ROUND WITH #3 PHILLIPS TRUSS ROUND WITH #3 PHILLIPS TRUSS LOW PROFILE MUSHROOM<br />

0.103 0.103 0.075<br />

0.425 0.425 0.480<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2 NYLON WITH GLASS ROUND 3 GALVALUME ROUND 3 GALVALUME<br />

ROUND 2 GALVALUME ROUND 2 GALVALUME<br />

REQUIRED<br />

REQUIRED<br />

REQUIRED<br />

REQUIRED<br />

OPTIONAL<br />

REQUIRED<br />

690 -- --<br />

610 -- 605<br />

535 782 576<br />

YES YES YES<br />

YES YES YES<br />

FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY FM<br />

YES YES YES<br />

X<br />

X<br />

507


<strong>Roof</strong> Fasteners: Steel Decks<br />

1. COMPANY NAME TREMCO INC. TREMCO INC.<br />

2. PRODUCT NAME STANDARD #1211 HEAVY DUTY #1410<br />

3. COUNTRY OF MANUFACTURE USA USA<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HEAT RESISTANT CARBON STEEL HEAT RESISTANT CARBON STEEL<br />

6. COATING TYPE CR-10 FLUOROCARBON CR-10 FLUOROCARBON<br />

7. SHANK TYPE THREADED THREADED<br />

8. POINT TYPE SELF-DRILLING SELF-DRILLING<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (INCHES) / SHANK LENGTH (INCHES) /<br />

THICKNESS (INCHES) / DECK PENETRATION (INCHES)<br />

0.168 1-5/8 1-1/8 3/4 0.190 1-1/4 3/4 3/4<br />

0.168 2-1/4 1-3/4 3/4 0.190 1-3/4 1-1/4 3/4<br />

0.168 2-7/8 2-3/8 3/4 0.190 2 1-1/2 3/4<br />

0.168 3-1/4 2-3/4 3/4 0.190 3 2-1/2 3/4<br />

0.168 3-3/4 3-1/4 3/4 0.190 4 3-1/2 3/4<br />

0.168 4-1/2 4 3/4 0.190 5 4-1/2 3/4<br />

0.168 5 4-1/2 3/4 0.190 6 5-1/2 3/4<br />

0.168 6 5-1/2 3/4 0.190 7 6-1/2 3/4<br />

0.168 7 6-1/2 3/4 0.190 8 7-1/2 3/4<br />

0.168 8 7-1/2 3/4 0.190 9 8-1/2 3/4<br />

0.190 10 9-1/2 3/4<br />

0.190 11 10-1/2 3/4<br />

0.190 12 11-1/2 3/4<br />

0.190 14 13-1/2 3/4<br />

0.190 16 15-1/2 3/4<br />

0.190 17 16-1/2 3/4<br />

0.201 18 17-1/2 3/4<br />

0.201 20 19-1/2 3/4<br />

0.201 21 20-1/2 3/4<br />

0.201 22 21-1/2 3/4<br />

0.201 24 23-1/2 3/4<br />

11. HEAD SHAPE ROUND TRUSS, #3 PHILLIPS ROUND TRUSS, #3 PHILLIPS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.110 0.110<br />

Diameter 0.435 0.435<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 2 STEEL ROUND 2 STEEL<br />

ROUND 3 STEEL ROUND 3 STEEL<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL OPTIONAL<br />

Special Tool Needed (optional/required)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

18 Gauge 540 585<br />

20 Gauge 501 535<br />

22 Gauge 456 505<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I STEEL ROOF DECK (yes/no) YES YES<br />

18. PASSES FM TEST PROCEDURE 4470 FOR CORROSION<br />

RESISTANCE (yes/no YES YES<br />

19. ACCEPTED BY THE FOLLOWING CODES FM, UL, ICBO, METRO-DADE COUNTY FM, UL, ICBO, METRO-DADE COUNTY<br />

20. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

21. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

508


<strong>Roof</strong> Fasteners: Steel Decks<br />

TRU-FAST CORPORATION TRU-FAST CORPORATION TRU-FAST CORPORATION<br />

HD DRILL POINT STAINLESS STEEL TP DP (DRILL POINT)<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

STAINLESS STEEL (TRIMTITE ALLOY #S-42010) CARBON STEEL C-1022 CARBON STEEL C-1022<br />

TRU-KOTE (FLUOROCARBON PAINT)<br />

TRU-KOTE (FLUOROCARBON PAINT)<br />

THREADED THREADED THREADED<br />

DOUBLE FLUTE SELF-DRILLING GIMLET DOUBLE FLUTE SELF-DRILLING<br />

THREADED THREADED THREADS<br />

0.180 1-1/2 1 3/4 0.150 1-5/8 1-1/8 3/4 0.160 1-5/8 1-1/8 3/4<br />

0.180 2 1-1/2 3/4 0.150 2-1/4 1-3/4 3/4 0.160 2-1/4 1-3/4 3/4<br />

0.180 3 2-1/2 3/4 0.150 2-7/8 2-3/8 3/4 0.160 2-7/8 2-3/8 3/4<br />

0.180 4 3-1/2 3/4 0.150 3-3/4 3-1/4 3/4 0.160 3-1/4 2-3/4 3/4<br />

0.180 5 4-1/2 3/4 0.150 4-1/2 4 3/4 0.160 3-3/4 3-1/4 3/4<br />

0.180 6 5-1/2 3/4 0.150 5 4-1/2 3/4 0.160 4-1/2 4 3/4<br />

0.180 7 6-1/2 3/4 0.150 6 5-1/2 3/4 0.160 5 4-1/2 3/4<br />

0.180 8 7-1/2 3/4 0.160 6 5-1/2 3/4<br />

0.180 10 9-1/2 3/4 0.160 7 6-1/2 3/4<br />

0.180 12 11-1/2 3/4 0.160 8 7-1/2 3/4<br />

TRUSS #3 PHILLIPS TRUSS #3 PHILLIPS TRUSS #3 PHILLIPS<br />

0.105 0.110 0.105<br />

0.440 0.390 0.440<br />

YES<br />

YES<br />

YES<br />

YES<br />

ROUND 3 GALVALUME ROUND 3 GALVALUME ROUND 3 GALVALUME<br />

ROUND 2 GALVALUME ROUND 2 GALVALUME ROUND 2 GALVALUME<br />

ROUND 2.4 GALVALUME ROUND 2.4 GALVALUME ROUND 2.4 GALVALUME<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

REQUIRED REQUIRED REQUIRED<br />

OPTIONAL OPTIONAL OPTIONAL<br />

830 558<br />

656 610 456<br />

472 494 452<br />

YES YES YES<br />

YES YES YES<br />

FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

YES YES YES<br />

509


<strong>Roof</strong> Fasteners: Steel Decks<br />

1. COMPANY NAME TRU-FAST CORPORATION TRU-FAST CORPORATION<br />

2. PRODUCT NAME HD (HEAVY DUTY) #14 EHD (EXTRA HEAVY DUTY) #15<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CARBON STEEL C-1022 CARBON STEEL C-1022<br />

6. COATING TYPE TRU-KOTE (FLUOROCARBON PAINT) TRU-KOTE PC-3 (FLUOROCARBON PAINT)<br />

7. SHANK TYPE THREADED THREADED<br />

8. POINT TYPE DOUBLE FLUTE SELF-DRILLING DOUBLE FLUTE SELF-DRILLING<br />

9. METHOD OF ATTACHMENT THREADS THREADS<br />

10. SHANK DIAMETER (INCHES) / SHANK LENGTH (INCHES) /<br />

THICKNESS (INCHES) / DECK PENETRATION (INCHES)<br />

0.180 1-1/2 1 3/4 0.204 1-1/4 3/4 1/2<br />

0.180 2 1-1/2 3/4 0.204 2 1-1/2 1/2<br />

0.180 3 2-1/2 3/4 0.204 3 2-1/2 1/2<br />

0.180 4 3-1/2 3/4 0.204 4 3-1/2 1/2<br />

0.180 5 4-1/2 3/4 0.204 5 4-1/2 1/2<br />

0.180 6 5-1/2 3/4 0.204 6 5-1/2 1/2<br />

0.180 7 6-1/2 3/4 0.204 7 6-1/2 1/2<br />

0.180 8 7-1/2 3/4 0.204 8 7-1/2 1/2<br />

0.180 10 9-1/2 3/4 0.204 9 8-1/2 1/2<br />

0.180 12 11-1/2 3/4 0.204 10 9-1/2 1/2<br />

0.204 11 10-1/2 1/2<br />

0.204 12 11-1/2 1/2<br />

0.204 14 13-1/2 1/2<br />

0.204 16 15-1/2 1/2<br />

0.204 18 19-1/2 1/2<br />

0.204 20 19-1/2 1/2<br />

11. HEAD SHAPE TRUSS #3 PHILLIPS TRUSS #3 PHILLIPS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.105 0.105<br />

Diameter 0.440 0.440<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 3 GALVALUME ROUND 3 GALVALUME<br />

ROUND 2 GALVALUME ROUND 2 GALVALUME<br />

ROUND 2.4 GALVALUME ROUND 2.4 GALVALUME<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

Installation Tool With Screw Gun (optional/required) REQUIRED REQUIRED<br />

Special Tool Needed (optional/required) OPTIONAL OPTIONAL<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

18 Gauge 850 --<br />

20 Gauge 656 --<br />

22 Gauge 472<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I STEEL ROOF DECK (yes/no) YES YES<br />

18. PASSES FM TEST PROCEDURE 4470 FOR CORROSION<br />

RESISTANCE (yes/no YES YES<br />

19. ACCEPTED BY THE FOLLOWING CODES FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

20. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

21. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

510


<strong>Roof</strong> Fasteners: Steel Decks<br />

U.S. INTEC U.S. INTEC U.S. INTEC<br />

DRILL-TEC II #12 DRILL-TEC II #14 DRILL-TEC II #15 (HIGH STRENGTH)<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

CARBON STEEL CARBON STEEL CARBON STEEL<br />

FLUOROPOLYMER PAINT FLUOROPOLYMER PAINT FLUOROPOLYMER PAINT<br />

THREADED THREADED THREADED<br />

DRILL POINT DRILL POINT THREADED, SELF- TAPPING<br />

MECHANICAL MECHANICAL MECHANICAL<br />

0.167 1-5/8 1-1/4 1 0.180 1-1/4 7/8 1 0.204 1-1/4 3/4 1<br />

0.167 2-1/4 2-1/4 1 0.180 1-5/8 1-1/4 1 0.204 2 1-1/2 1<br />

0.167 2-7/8 2-1/2 1 O.180 2-1/4 1-7/8 1 0.204 3 2-1/2 1<br />

0.167 3-1/4 2-7/8 1 0.180 2-7/8 2-1/2 1 0.204 4 3-1/2 1<br />

0.167 3-3/4 3-3/8 1 0.180 3-1/4 2-7/8 1 0.204 5 4-1/2 1<br />

0.167 4-1/2 4-1/8 1 0.180 3-3/4 3-7/8 1 0.204 6 5-1/2 1<br />

0.167 5 4-5/8 1 0.180 4-1/2 4-1/8 1 0.204 7 6-1/2 1<br />

0.167 6 5-5/8 1 0.180 5 4-5/8 1 0.204 8 7-1/2 1<br />

0.167 7 6-5/8 1 0.180 6 5-5/8 1 0.204 10 9-1/2 1<br />

0.167 8 7-5/8 1 0.180 7 6-5/8 1 0.204 12 11-1/2 1<br />

0.180 8 7-5/8 1 0.204 14 13-1/2 1<br />

0.180 10 9-5/8 1 0.204 16 15-1/2 1<br />

0.180 12 11-5/8 1 0.204 18 19-1/2 1<br />

0.204 20 19-1/2 1<br />

0.204 22 21-1/2 1<br />

0.204 24 23-1/2 1<br />

0.204 26 25-1/2 1<br />

HEX OR #3 PHILLIPS TRUSS # 3 PHILLIPS TRUSS #3 PHILLIPS<br />

0.118 0.130<br />

0.448 0.448<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2.7 GALVALUME ROUND 2.7 GALVALUME ROUND 2.5 GALVALUME<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC HEX 2.7 GALVALUME<br />

HEX 2.7 GALVALUME HEX 2.7 GALVALUME<br />

REQUIRED REQUIRED REQUIRED<br />

OPTIONAL OPTIONAL OPTIONAL<br />

OPTIONAL OPTIONAL OPTIONAL<br />

558<br />

456<br />

452<br />

YES YES YES<br />

YES YES YES<br />

FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

YES YES YES<br />

511


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME CARLISLE SYNTEC INCORPORATED CARLISLE SYNTEC INCORPORATED<br />

2. PRODUCT NAME HP FASTENER HP WOODIE<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CARBON STEEL ZAMAC<br />

6. COATING TYPE EPOXY ELECTRODEPOSITION<br />

7. SHANK TYPE SINGLE LEAD, BUTTRESS THREAD SPIRALTHREAD<br />

8. POINT TYPE MINI-DRILL POINT PIERCE-POINT<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.180 1-1/4 1/4 1 1 0.500 1-3/4 0 -- --<br />

0.180 1-3/4 3/4 1 1 0.500 2-1/2 1/2 <strong>to</strong> 3/4 -- --<br />

0.180 2-1/4 1-1/4 1 1 0.500 3-1/4 1 <strong>to</strong> 1-1/2 -- --<br />

0.180 2-3/4 1-3/4 1 1<br />

0.180 3-1/4 2-1/4 1 1<br />

0.180 3-3/4 2-3/4 1 1<br />

0.180 4-1/4 3-1/4 1 1<br />

0.180 5 4 1 1<br />

0.180 6 5 1 1<br />

0.180 7 6 1 1<br />

0.180 8 7 1 1<br />

0.180 9 8 1 1<br />

0.180 10 9 1 1<br />

0.180 11 10 1 1<br />

0.180 12 11 1 1<br />

0.180 13 12 1 1<br />

0.180 14 13 1 1<br />

0.180 15 14 1 1<br />

11. HEAD SHAPE WAFER FLUSH RECESS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.105 0.073<br />

Diameter 0.430 0.600<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

SQUARE W/ROUNDED ROUND 2 GALVALUME<br />

CORNER 2-7/8 GALVALUME ROUND 3 GALVALUME<br />

ROUND 2 GALVALUME<br />

LOCKING 2 GALVALUME W/<br />

PLASTIC<br />

ROUND 2 PLASTIC<br />

ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

Other<br />

AUTOMATIC FASTENING TOOL<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood -- --<br />

2-inch pine plank -- --<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM FM<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

512


<strong>Roof</strong> Fasteners: Wood Decks<br />

CARLISLE SYNTEC INCORPORATED CARLISLE SYNTEC INCORPORATED CARLISLE SYNTEC INCORPORATED<br />

HP-X FASTENER SURE FAST FASTENERS CARLISLE ASAP<br />

U.S. U.S. U.S.<br />

X<br />

X<br />

X<br />

CARBON STEEL CARBON STEEL CARBON STEEL<br />

EPOXY ELECTRODEPOSITION EPOXY ELECTRODEPOSITION EPOXY ELECTRODEPOSITION<br />

SINGLE LEAD, BUTTRESS THREAD SINGLE LEAD, BUTTRESS THREAD SINGLE LEAD, BUTTRESS THREAD<br />

DRILL POINT DRILL POINT 30º SPADE POINT<br />

THREADED THREADED THREADED<br />

0.201 2 1 1 -- 0.160 2-1/4 1-1/4 1 1 0.165 2-1/4 1-1/4 1 1<br />

0.201 3 2 1 -- 0.160 2-7/8 1-7/8 1 1 0.165 2-7/8 1-7/8 1 1<br />

0.201 4 3 1 -- 0.160 3-1/4 2-1/4 1 1 0.165 3-1/4 2-1/4 1 1<br />

0.201 5 4 1 -- 0.160 3-3/4 2-3/4 1 1 0.165 3-3/4 2-3/4 1 1<br />

0.201 6 5 1 -- 0.160 4-1/2 3-1/2 1 1 0.165 4-1/2 3-1/2 1 1<br />

0.201 7 6 1 -- 0.160 5 4 1 1 0.165 5 4 1 1<br />

0.201 8 7 1 -- 0.160 6 5 1 1 0.165 6 5 1 1<br />

0.201 10 9 1 -- 0.160 7 6 1 1 0.165 7 6 1 1<br />

0.201 12 11 1 -- 0.160 8 7 1 1 0.165 8 7 1 1<br />

0.201 14 13 1 --<br />

TRUSS, #3 PHILLIPS TRUSS #3 PHILLIPS TRUSS #3 PHILLIPS<br />

0.115 0.100 0.115<br />

0.435 0.425 0.435<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2-3/8 CARBON STEEL ROUND 3 GALVALUME ROUND 3 GALVALUME<br />

REQUIRED REQUIRED REQUIRED<br />

AUTOMATIC FASTENING TOOL<br />

AUTOMATIC FASTENING TOOL<br />

--<br />

--<br />

YES<br />

YES<br />

FM<br />

FM<br />

YES YES YES<br />

513


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME CELOTEX CORPORATION CELOTEX CORPORATION<br />

2. PRODUCT NAME ANCHORBOND #12 ANCHORBOND #14<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HARDENED CARBON STEEL HARDENED CARBON STEEL<br />

6. COATING TYPE ORGANIC FLUOROPOLYMERS ORGANIC FLUOROPOLYMERS<br />

7. SHANK TYPE SPIRAL THREAD SPIRAL THREAD<br />

8. POINT TYPE SELF-DRILLING SELF-DRILLING<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.222 1-5/8 5/8 3/4 1 0.238 1-1/4 1/4 3/4 1<br />

0.222 2-1/4 1-1/4 3/4 1 0.238 1-5/8 5/8 3/4 1<br />

0.222 2-7/8 1-7/8 3/4 1 0.238 1-7/8 1-1/4 3/4 1<br />

0.222 3-3/4 2-3/4 3/4 1 0.238 2-7/8 1-7/8 3/4 1<br />

0.222 4-1/2 3-1/2 3/4 1 0.238 3-1/4 2-1/4 3/4 1<br />

0.222 5 4 3/4 1 0.238 3-3/4 2-3/4 3/4 1<br />

0.238 4-1/2 3-1/2 3/4 1<br />

0.238 5 4 3/4 1<br />

0.238 6 5 3/4 1<br />

0.238 7 6 3/4 1<br />

0.238 8 7 3/4 1<br />

11. HEAD SHAPE #3 PHILLIPS TRUSS & 1/4" HEX WASHER HEAD # 3 PHILLIPS FLAT TRUSS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.109 0.109<br />

Diameter 0.438 0.438<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

HEXAGONAL 2-7/8 GALVALUME HEXAGONAL 2-7/8 STAINLESS STEEL<br />

HEXAGONAL 2-7/8 GALVALUME<br />

HEXAGONAL 3 PLASTIC<br />

ROUND 2 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL OPTIONAL<br />

Special Tool Needed (optional/required)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 617 671<br />

2-inch pine plank 1265 1470<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM FM<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X<br />

NA = not applicable<br />

514


<strong>Roof</strong> Fasteners: Wood Decks<br />

CELOTEX CORPORATION CELOTEX CORPORATION CONSTRUCTION FASTENERS, INC.<br />

ANCHORBOND #15 HEAVY DUTY ANCHORBOND #14 STAINLESS STEEL DEKFAST #12<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

HARDENED CARBON STEEL STAINLESS STEEL (#304) HARDENED CARBON STEEL<br />

ORGANIC FLUOROPOLYMERS ORGANIC FLUOROPOLYMERS ORGANIC<br />

SPIRAL THREAD SPIRAL THREAD SPIRAL THREAD<br />

SELF-DRILLING SELF-DRILLING SELF-DRILLING<br />

THREADED THREADED THREADED<br />

0.264 1-1/4 1/4 3/4 1 0.264 3 1-1/2 3/4 1 0.222 1-5/8 5/8 1 1<br />

0.264 2 1 3/4 1 0.264 4 2-1/2 3/4 1 0.222 2-1/4 1-1/4 1 1<br />

0.264 3 2 3/4 1 0.264 5 3-1/2 3/4 1 0.222 2-7/8 1-7/8 1 1<br />

0.264 4 3 3/4 1 0.264 6 4-1/2 3/4 1 0.222 3-1/4 2-1/4 1 1<br />

0.264 5 4 3/4 1 0.264 7 5-1/2 3/4 1 0.222 3-3/4 2-3/8 1 1<br />

0.264 6 5 3/4 1 0.264 8 6-1/2 3/4 1 0.222 4-1/2 3-1/2 1 1<br />

0.264 7 6 3/4 1 0.222 5 4 1 1<br />

0.264 8 7 3/4 1 0.222 6 5 1 1<br />

0.264 10 9 3/4 1 0.222 7 6 1 1<br />

0.264 12 11 3/4 1 0.222 8 7 1 1<br />

0.264 14 13 3/4 1<br />

0.264 16 15 3/4 1<br />

#3 PHILLIPS TRUSS # 3PHILLIPS TRUSS #3 PHILLIPS TRUSS & 1/4" HEX WASHER HEAD<br />

0.109 0.109 0.118, 0.190<br />

0.438 0.438 0.448, 0.448<br />

YES YES YES<br />

YES YES YES<br />

HEXAGONAL 2-7/8 STAINLESS STEEL HEXAGONAL 2-7/8 STAINLESS STEEL HEXAGONAL 2-7/8 RECESS GALVALUME<br />

HEXAGONAL 2-7/8 GALVALUME HEXAGONAL 2-7/8 GALVALUME HEXAGONAL 2-7/8 GALVALUME<br />

ROUND 2 GALVALUME HEXAGONAL 3 PLASTIC HEXAGONAL 3 PLASTIC<br />

ROUND 2 GALVALUME ROUND 2 GALVALUME<br />

ROUND 2 NYLON<br />

ROUND 2 PLASTIC<br />

REQUIRED REQUIRED REQUIRED<br />

OPTIONAL OPTIONAL OPTIONAL<br />

780 773 575<br />

1500 1250 1816<br />

YES YES YES<br />

FM FM FM, METRO-DADE COUNTY<br />

YES YES YES<br />

X<br />

515


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME CONSTRUCTION FASTENERS, INC. CONSTRUCTION FASTENERS, INC.<br />

2. PRODUCT NAME DEKFAST #14 DEKFAST #15 HI-STRENGTH<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HARDENED CARBON STEEL HARDENED CARBON STEEL<br />

6. COATING TYPE ORGANIC ORGANIC<br />

7. SHANK TYPE SPIRAL THREAD SPIRAL THREAD<br />

8. POINT TYPE SELF-DRILLING SELF-DRILLING<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.238 1-1/4 1/4 1 1 0.264 1-1/4 1/4 1 1<br />

0.238 1-5/8 5/8 1 1 0.264 2 1 1 1<br />

0.238 2-1/4 1-1/4 1 1 0.264 3 2 1 1<br />

0.238 2-7/8 1-7/8 1 1 0.264 4 3 1 1<br />

0.238 3-1/4 2-1/4 1 1 0.264 5 4 1 1<br />

0.238 3-3/4 2-3/8 1 1 0.264 6 5 1 1<br />

0.238 4-1/2 3-1/2 1 1 0.264 7 6 1 1<br />

0.238 5 4 1 1 0.264 8 7 1 1<br />

0.238 6 5 1 1 0.264 10 9 1 1<br />

0.238 7 6 1 1 0.264 12 11 1 1<br />

0.238 8 7 1 1 0.264 14 13 1 1<br />

0.238 10 9 1 1 0.264 16 15 1 1<br />

0.238 12 11 1 1 0.264 18 17 1 1<br />

0.264 20 19 1 1<br />

0.264 22 21 1 1<br />

0.264 24 23 1 1<br />

0.264 26 25 1 1<br />

11. HEAD SHAPE #3 PHILLIPS FLAT TRUSS # 3 PHILLIPS TRUSS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.118 0.130<br />

Diameter 0.448 0.448<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

HEXAGONAL 2-7/8 GALVALUME HEXAGONAL 2-7/8 GALVALUME<br />

HEXAGONAL 3 PLASTIC ROUND 2 GALVALUME<br />

ROUND 2 GALVALUME ROUND 2-1/2 GALVALUME<br />

ROUND 2 NYLON ROUND 3 PLASTIC<br />

ROUND 2 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL OPTIONAL<br />

Special Tool Needed (optional/required)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 590 703<br />

2-inch pine plank 1943 2217<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

516


<strong>Roof</strong> Fasteners: Wood Decks<br />

CONSTRUCTION FASTENERS, INC. DURO LAST INC. ES PRODUCTS INC.<br />

#14 DEKFAST STAINLESS STEEL DURO LAST SCREWS #14 HARDENED DO-ALL LOC-NAIL<br />

U.S. U.S. U.S.<br />

X<br />

X<br />

X<br />

X X X<br />

STAINLESS STEEL (TRIMRITE) STEEL HARDENED COLD ROLL STEEL<br />

NONE FLUOROCARBON ZINC PLATED<br />

SPIRAL THREAD SPIRAL THREAD SPLIT, SERRATED<br />

SELF-DRILLING SELF-DRILLING 2 SHARP POINTS<br />

THREADED THREADED SPREAD OF SERRATED SHANKS<br />

0.235 1-1/4 1/2 1 1 0.190 1-3/4 3/4 1 1 0.240 1-3/8 1/4 1/2 1<br />

0.235 2 1 1 1 0.190 2 1 1 1<br />

0.235 3 2 1 1 0.190 2-1/2 1-1/2 1 1<br />

0.235 4 3 1 1 0.190 3 2 1 1<br />

0.235 5 4 1 1 0.190 3-1/2 2-1/2 1 1<br />

0.235 6 5 1 1 0.190 4 3 1 1<br />

0.235 7 6 1 1 0.190 4-1/2 3-1/2 1 1<br />

0.235 8 7 1 1 0.190 5 4 1 1<br />

0.235 10 9 1 1 0.190 5-1/2 4-1/2 1 1<br />

0.235 12 11 1 1 0.190 6 5 1 1<br />

0.190 7 6 1 1<br />

0.190 8 7 1 1<br />

0.190 9 8 1 1<br />

0.190 10 9 1 1<br />

0.190 11 10 1 1<br />

0.190 12 11 1 1<br />

#3 PHILLIPS TRUSS #3 PHILLIPS TRUSS SQUARE WITH ROUNDED CORNERS<br />

0.118 0.103 0.050<br />

0.440 0.438 0.375<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2 GALVALUME ROUND (SEAM) 2 GALVALUME ROUND 1-3/16 PRE-TINNED STEEL<br />

ROUND 3 GALVALUME ROUND (INSUL) 3 PLASTIC<br />

ROUND 3 PLASTIC SQUARE (INSUL) 3 GALVALUME<br />

REQUIRED<br />

OPTIONAL<br />

REQUIRED<br />

OPTIONAL<br />

HAMMER<br />

590 930 134<br />

1943 983 141<br />

YES<br />

FM, METRO-DADE COUNTY<br />

YES<br />

FM, ICBO, BOCA, SBCCI, UL, METRO-DADE CNTY<br />

YES YES YES<br />

X<br />

517


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME FIRESTONE BUILDING PRODUCTS FIRESTONE BUILDING PRODUCTS<br />

2. PRODUCT NAME FIRESTONE ALL PURPOSE FIRESTONE HEAVY DUTY<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE SAE 1022, HEAT TREATED SAE 1022, HEAT TREATED<br />

6. COATING TYPE EPOXY EPOXY<br />

7. SHANK TYPE SPIRAL THREADED BUTTRESS THREAD<br />

8. POINT TYPE DRILL POINT DRILL POINT<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.235 1-1/4 1/4 1 1 0.264 1-1/4 1/4 1 1<br />

0.235 1-5/8 5/8 1 1 0.264 2 1 1 1<br />

0.235 2-1/4 1-1/4 1 1 0.264 3 2 1 1<br />

0.235 2-7/8 1-7/8 1 1 0.264 4 3 1 1<br />

0.235 3-1/4 2-1/4 1 1 0.264 5 4 1 1<br />

0.235 3-3/4 1-3/4 1 1 0.264 6 5 1 1<br />

0.235 4-1/2 3-1/2 1 1 0.264 7 6 1 1<br />

0.235 5 4 1 1 0.264 8 7 1 1<br />

0.235 6 5 1 1 0.264 10 9 1 1<br />

0.235 7 6 1 1 0.264 12 11 1 1<br />

0.235 8 7 1 1 0.264 14 13 1 1<br />

11. HEAD SHAPE ROUND MUSHROOM #3 PHILLIPS ROUND MUSHROOM #3 PHILLIPS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.110 0.110<br />

Diameter 0.437 0.437<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

HEX (INSULATION) 2-7/8 GALVALUME HEX (INSULATION) 2-7/8 GALVALUME<br />

ROUND (IN-SEAM) 2 GALVALUME ROUND (IN-SEAM) 2 GALVALUME<br />

ROUND (IN-SEAM) 2-3/8 GALVALUME ROUND (IN-SEAM) 2-3/8 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL OPTIONAL<br />

Special Tool Needed (optional/required)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 520 620<br />

2-inch pine plank 900 900<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, ICBO, UL, SBCCI FM, ICBO, UL, SBCCI<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

518


<strong>Roof</strong> Fasteners: Wood Decks<br />

FIRESTONE BUILDLING PRODUCTS GAF MATERIALS CORP. GAF MATERIALS CORP.<br />

PRE-ASSEMBLED FASTENER GAFTITE #12-11/EVERGUARD EGIN GAFTITE #12-11/EVERGUARD EGIN<br />

U.S. U.S. U.S.<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

C-1022, HEAT TREATED HARDENED CARBON STEEL STAINLESS STEEL, SPECIAL 400-SERIES BLEND<br />

EPOXY CR-10 FLUOROCARBON CR-10 FLUOROCARBON<br />

SPIRAL THREADED THREADED THREADED<br />

DRILL POINT PINCH, SELF-DRILLING, GIMLET OR TAPEX PINCH, SELF-DRILLING<br />

THREADED THREADED THREADED<br />

0.196 2-1/4 1 1 0.160 1-5/8 5/8 1/2 1 0.160 1-5/8 1-3/8 1/2 1<br />

0.196 2-7/8 1 1 0.160 2-1/4 1-1/4 1/2 1 0.160 2-1/4 1-3/4 1/2 1<br />

0.196 3-1/4 1 1 0.160 2-7/8 1-7/8 1/2 1 0.160 2-7/8 2-3/8 1/2 1<br />

0.196 4-1/2 1 1 0.160 3-1/4 2-1/4 1/2 1 0.160 3-1/4 2-3/4 1/2 1<br />

0.196 5 1 1 0.160 3-3/4 2-3/4 1/2 1 0.160 3-3/4 3-1/4 1/2 1<br />

0.196 6 1 1 0.160 4-1/2 3-1/2 1/2 1 0.160 4-1/2 4 1/2 1<br />

0.196 7 1 1 0.160 5 4 1/2 1 0.160 5 4-1/2 1/2 1<br />

0.196 8 1 1 0.160 6 5 1/2 1 0.160 6 5-1/2 1/2 1<br />

0.160 7 6 1/2 1 0.160 7 6-1/2 1/2 1<br />

0.160 8 7 1/2 1 0.160 8 7-1/2 1/2 1<br />

#3 PHILLIPS TRUSS ROUND TRUSS, #3 PHILLIPS ROUND TRUSS, #3 PHILLIPS<br />

0.100 0.110 0.110<br />

0.433 0.435 0.435<br />

YES YES YES<br />

YES YES YES<br />

HEX 2-7/8 GALVALUME ROUND 2 STEEL ROUND 2 STAINLESS STEEL<br />

ROUND 2 PLASTIC ROUND 3 STAINLESS STEEL<br />

ROUND 2 STAINLESS STEEL ROUND 2 STEEL<br />

ROUND 3 STEEL ROUND 2 PLASTIC<br />

ROUND 3 PLASTIC ROUND 3 STEEL<br />

ROUND 3 STAINLESS STEEL ROUND 3 PLASTIC<br />

REQUIRED REQUIRED REQUIRED<br />

OPTIONAL OPTIONAL OPTIONAL<br />

500 531 531<br />

1200 735 735<br />

YES YES YES<br />

FM, ICBO, UL, SBCCI FM, ICBO,UL, METRO-DADE COUNTY FM, ICBO, UL, METRO-DADE COUNTY<br />

YES YES YES<br />

X<br />

X<br />

519


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME GAF MATERIALS CORP. GAF MATERIALS CORP.<br />

2. PRODUCT NAME GAFTITE #14-10/EVEGUARD EGHD GAFTITE #14-10/EVEGUARD EGHD<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HARDENED CARBON STEEL STAINLESS STEEL, SPECIAL 400-SERIES BLEND<br />

6. COATING TYPE CR-10 FLUOROCARBON CR-10 FLUOROCARBON<br />

7. SHANK TYPE PINCH, SELF-DRILLING OR TAPEX THREADED<br />

8. POINT TYPE THREADED PINCH, SELF-DRILLING<br />

9. METHOD OF ATTACHMENT THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.190 1-1/4 1/2 1/2 1 0.201 1-1/4 1/2 1/2 1<br />

0.190 1-3/4 3/4 1/2 1 0.201 1-3/4 3/4 1/2 1<br />

0.190 2 1 1/2 1 0.201 2 1 1/2 1<br />

0190 3 2 1/2 1 0.201 3 2 1/2 1<br />

0.190 4 3 1/2 1 0.201 4 3 1/2 1<br />

0190 5 4 1/2 1 0.201 5 4 1/2 1<br />

0.190 6 5 1/2 1 0.201 6 5 1/2 1<br />

0.190 7 6 1/2 1 0.201 7 6 1/2 1<br />

0.190 8 7 1/2 1 0.201 8 7 1/2 1<br />

0.190 10 9 1/2 1 0.201 9 8 1/2 1<br />

0.190 12 11 1/2 1 0.201 10 9 1/2 1<br />

0.190 14 13 1/2 1 0.201 12 11 1/2 1<br />

0.190 16 15 1/2 1 0.201 14 13 1/2 1<br />

0.190 17 16 1/2 1 0.201 16 15 1/2 1<br />

0.190 18 17 1/2 1 0.201 18 17 1/2 1<br />

0.190 20 19 1/2 1 0.201 20 19 1/2 1<br />

0.190 21 20 1/2 1 0.201 21 20 1/2 1<br />

0.190 22 21 1/2 1 0.201 22 21 1/2 1<br />

0.190 24 23 1/2 1 0.201 24 23 1/2 1<br />

11. HEAD SHAPE ROUND TRUSS, #3 PHILLIPS ROUND TRUSS, #3 PHILLIPS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.110 0.108<br />

Diameter 0.435 0.435<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 2 STAINLESS STEEL ROUND 2 STAINLESS STEEL<br />

ROUND 3 STAINLESS STEEL ROUND 3 STAINLESS STEEL<br />

ROUND 2 STEEL ROUND 2 STEEL<br />

ROUND 2 PLASTIC ROUND 2 PLASTIC<br />

ROUND 3 STEEL ROUND 3 STEEL<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL OPTIONAL<br />

Special Tool Needed (optional/required)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 590 590<br />

2-inch pine plank 820 820<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, ICBO, UL, METRO-DADE COUNTY FM, ICBO, UL, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

520


<strong>Roof</strong> Fasteners: Wood Decks<br />

ITW BUILDEX ITW BUILDEX ITW BUILDEX<br />

HEXTRA ROOFGRIP ACCUTRAC FASTENER<br />

U.S. U.S. U.S.<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

HARDENED CARBON STEEL HARDENED CARBON STEEL OR STAINLESS STEEL HARDENED CARBON STEEL<br />

CLIMASEAL OR SPEX SPEX CLIMASEAL<br />

MODIFIED BUTTRESS THREAD MODIFIED BUTTRESS THREAD MODIFIED BUTTRESS THREAD<br />

X-POINT X-POINT X-POINT<br />

THREADED THREADED THREADED<br />

0.215 1-5/8 5/8 1 1 0.215 1-5/8 5/8 1 1 0.215 1-5/8 5/8 1/2 1/2<br />

0.215 2-1/4 1-1/4 1 1 0.215 2-1/4 1-1/4 1 1 0.215 2-1/4 1-1/4 1/2 1/2<br />

0.215 2-7/8 1-7/8 1 1 0.215 2-7/8 1-7/8 1 1 0.215 2-7/8 1-7/8 1/2 1/2<br />

0.215 3-1/4 2-1/4 1 1 0.215 3-1/4 2-1/4 1 1 0.215 3-1/4 2-1/4 1/2 1/2<br />

0.215 3-3/4 2-3/4 1 1 0.215 3-3/4 2-3/4 1 1 0.215 3-3/4 2-3/4 1/2 1/2<br />

0.215 4-3/8 3-3/8 1 1 0.215 4-3/8 3-3/8 1 1 0.215 4-3/8 3-3/8 1/2 1/2<br />

0.215 5 4 1 1 0.215 5 4 1 1 0.215 5 4 1/2 1/2<br />

0.215 6 5 1 1 0.215 6 5 1 1 0.215 6 5 1/2 1/2<br />

0.215 7 6 1 1 0.215 7 6 1 1<br />

0.215 8 7 1 1 0.215 8 7 1 1<br />

1/4-IN. HEX HEAD #3 PHILLIPS PAN HEAD 1/4 IN. HEX HEAD OR #3 PHILLIPS<br />

0.180 0.118 0.180<br />

0.392 0.448 0.392<br />

YES YES YES<br />

YES YES YES<br />

SQUARE 3 X 3 GALVALUME SQUARE 3 X 3 GALVALUME SQUARE 3 X 3 GALVALUME<br />

GEARLOCK 3 POLYOLEFIN GEARLOCK 3 POLYOLEFIN<br />

ROUND 2 GALVALUME ROUND 2 GALVALUME<br />

REQUIRED<br />

REQUIRED<br />

ACCURIVE XL PLUS (OPTIONAL) ACCURIVE XL PLUS (OPTIONAL) ACCUTRAC I, II, OR III (REQUIRED)<br />

544 544 544<br />

1292 1292 1292<br />

YES YES YES<br />

FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

YES YES YES<br />

X<br />

521


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME ITW BUILDEX ITW BUILDEX<br />

2. PRODUCT NAME ROOFGRIP PLUS #14 ROOFGRIP<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

X<br />

Single-Ply Membranes<br />

X<br />

5. MATERIAL TYPE CARBON STEEL HARDENED CARBON STEEL<br />

6. COATING TYPE SPEX CLIMASEAL<br />

7. SHANK TYPE MODIFIED BUTTRESS THREAD MODIFIED STANDARD THREAD<br />

8. POINT TYPE X-POINT X-POINT<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.215 2-1/4 1-1/4 1/2 1/2 0.245 1-1/2 1 1/2 1/2<br />

0.215 2-7/8 2-3/8 1/2 1/2 0.245 2 1-1/2 1/2 1/2<br />

0.215 3-1/4 2-3/4 1/2 1/2 0.245 3 2-1/2 1/2 1/2<br />

0.215 3-3/4 3-1/4 1/2 1/2 0.245 4 3-1/2 1/2 1/2<br />

0.215 4-3/8 3-7/8 1/2 1/2 0.245 5 4-1/2 1/2 1/2<br />

0.215 5 4-1/2 1/2 1/2 0.245 6 5-1/2 1/2 1/2<br />

0.215 6 5 1/2 1/2 0.245 7 6-1/2 1/2 1/2<br />

0.215 7 6 1/2 1/2 0.245 8 7-1/2 1/2 1/2<br />

0.215 8 7 1/2 1/2<br />

11. HEAD SHAPE #3 PHILLIPS PAN HEAD #3 PHILLIPS PAN HEAD<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.180 0.118<br />

Diameter 0.392 0.448<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 3 GALVALUME ROUND 2 GALVALUME<br />

SQUARE 3 GALVALUME<br />

ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required) ACCUFAST STAND-UP TOOL (OPTIONAL) ACCUDRIVE XL PLUS (OPTIONAL)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 544 728<br />

2-inch pine plank 1292 1104<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM FM, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X<br />

NA = not applicable<br />

522


<strong>Roof</strong> Fasteners: Wood Decks<br />

ITW BUILDEX ITW BUILDEX JOHNS MANVILLE INTERNATIONAL INC.<br />

#15 ROOFGRIP HEXTRA PLUS ULTRAFAST/HEX HEAD<br />

U.S. U.S. U.S.<br />

X<br />

X<br />

X<br />

X<br />

X<br />

HARDENED CARBON STEEL CARBON STEEL HARDENED CARBON STEEL<br />

CLIMASEAL CLIMASEAL CLIMASEAL<br />

MODIFIED STANDARD THREAD MODIFIED STANDARD THREAD MODIFIED BUTTRESS THREAD<br />

DRILL-POINT X-POINT SELF-DRILLING X-POINT<br />

THREADED THREADED THREADED<br />

0.260 1-1/4 3/4 1/2 1/2 0.215 2-1/4 1-3/4 1/2 1/2 0.215 1-5/8 5/8 1 1<br />

0.260 2 1-1/2 1/2 1/2 0.215 2-7/8 2-3/8 1/2 1/2 0.215 2-1/4 1-1/4 1 1<br />

0.260 3 2-1/2 1/2 1/2 0.215 3-1/4 2-3/4 1/2 1/2 0.215 2-7/8 1-7/8 1 1<br />

0.260 4 3-1/2 1/2 1/2 0.215 3-3/4 3-1/4 1/2 1/2 0.215 3-1/4 2-1/4 1 1<br />

0.260 5 4-1/2 1/2 1/2 0.215 4-3/8 3-3/8 1/2 1/2 0.215 3-3/4 2-3/4 1 1<br />

0.260 6 5-1/2 1/2 1/2 0.215 5 4-1/2 1/2 1/2 0.215 4-3/8 3-3/8 1 1<br />

0.260 7 6-1/2 1/2 1/2 0.215 6 5-1/2 1/2 1/2 0.215 5 4 1 1<br />

0.260 8 7-1/2 1/2 1/2 0.215 7 6-1/2 1/2 1/2 0.215 6 5 1 1<br />

0.260 10 9-1/2 1/2 1/2 0.215 8 7-1/2 1/2 1/2 0.215 7 6 1 1<br />

0.260 12 11-1/2 1/2 1/2 0.215 8 7 1 1<br />

0.260 14 13-1/2 1/2 1/2<br />

0.260 16 15-1/2 1/2 1/2<br />

#3 PHILLIPS PAN HEAD 1/4-IN. HEX HEAD 1/4-IN. HEX HEAD<br />

0.118 0.180 0.180<br />

0.448 0.392 0.392<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2 GALVALUME ROUND 2 GALVALUME SQUARE 3 X 3 CARBON STEEL W/<br />

SQUARE 3 GALVALUME GALVALUME<br />

ROUND MANVILLE 3 POLYOLEFIN<br />

LOCKING PLATE<br />

REQUIRED REQUIRED REQUIRED<br />

OPTIONAL (ACCUDRIVE)<br />

ACCUDRIVE XL PLUS (OPTIONAL)<br />

ACCUFAST STAND-UP TOOL (OPTIONAL)<br />

606 544 544<br />

1410 1292 1292<br />

YES YES YES<br />

FM FM FM, UL, METRO-DADE COUNTY<br />

YES YES YES<br />

X<br />

523


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME JOHNS MANVILLE INTERNATIONAL INC. NATIONAL NAIL CORPORATION<br />

2. PRODUCT NAME ULTRA GRIP PHILLIPS HEAD #12 R/S ROUND-TOP<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

X<br />

Single-Ply Membranes<br />

X<br />

5. MATERIAL TYPE HARDENED CARBON STEEL CARBON STEEL<br />

6. COATING TYPE SPEX NATIONAL NAIL CORPORATION<br />

7. SHANK TYPE MODIFIED BUTTRESS THREAD ANULAR THREADED<br />

8. POINT TYPE SELF-DRILLING X-POINT DIAMOND<br />

9. METHOD OF ATTACHMENT THREADED THREADED FRICTION<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.215 1-5/8 5/8 1 1 0.990 3/4 1/8 1 1<br />

0.215 2-1/4 1-1/4 1 1 0.990 7/8 1/8 1 1<br />

0.215 2-7/8 1-7/8 1 1 0.990 1 1/8 1 1<br />

0.215 3-1/4 2-1/4 1 1 0.990 1-1/4 1/2 1 1<br />

0.215 3-3/4 2-3/4 1 1 0.990 1-1/2 3/4 1 1<br />

0.215 4-3/8 3-3/8 1 1 0.990 1-3/4 1 1 1<br />

0.215 5 4 1 1 0.990 2 1-1/4 1 1<br />

0.215 6 5 1 1 0.990 2-1/2 1-3/4 1 1<br />

0.215 7 6 1 1 0.990 3 2-1/4 1 1<br />

0.215 8 7 1 1<br />

11. HEAD SHAPE #3 PHILLIPS ROUND<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.118 0.045<br />

Diameter 0.448 1.00<br />

13. PLATES<br />

Required (yes/no) YES NO<br />

Available From Manufacturer (yes/no)<br />

YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

SQUARE 3 X 3 CARBON STEEL W/ -- -- --<br />

GALVALUME<br />

ROUND MANVILLE 3 POLYOLEFIN<br />

LOCKING PLATE<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

OPTIONAL (ACCUDRIVE)<br />

Special Tool Needed (optional/required)<br />

Other<br />

HAMMER (REQUIRED)<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 544 --<br />

2-inch pine plank 1292 --<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) YES NO<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, UL, METRO-DADE COUNTY BOCA, ICBO<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) NO YES<br />

20. SEE APPENDIX IF CHECKED X<br />

NA = not applicable<br />

524


<strong>Roof</strong> Fasteners: Wood Decks<br />

NATIONAL NAIL CORPORATION NATIONAL NAIL CORPORATION NATIONAL NAIL CORPORATION<br />

ROUND-TOP MASONRY PLASTI-TOP PLASTI-CAP<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

HIGH CARBON STEEL CARBON STEEL CARBON STEEL<br />

NATIONAL NAIL CORPORATION NA NA<br />

FLUTED ANNULAR THREAD SPIRAL THREAD<br />

DIAMOND DIAMOND DIAMOND<br />

THREADED FRICTION THREADED FRICTION THREADED FRICTION<br />

0.164 5/8 1/8 1/2 1 0.990 3/4 1/8 1 1 0.110 3/4 1/8 1 1<br />

0.164 3/4 1/8 1/2 1 0.990 7/8 1/8 1 1 0.110 7/8 1/8 1 1<br />

0.164 7/8 1/8 1/2 1 0.990 1 1/8 1 1 0.110 1 1/8 1 1<br />

0.164 1 1/2 1/2 1 0.990 1-1/4 1/2 1 1 0.110 1-1/4 1/2 1 1<br />

0.164 1-1/4 3/4 1/2 1 0.990 1-1/2 3/4 1 1 0.110 1-1/2 3/4 1 1<br />

0.164 1-1/2 1 1/2 1 0.990 1-3/4 1 1 1 0.110 1-3/4 1 1 1<br />

0.164 1-3/4 1-1/4 1/2 1 0.990 2 1-1/4 1 1 0.110 2 1-1/4 1 1<br />

0.164 2 1-1/2 1/2 1 0.990 2-1/2 1-3/4 1 1 0.110 2-1/2 1-3/4 1 1<br />

0.164 2-1/2 2 1/2 1 0.990 3 2-1/4 1 1 0.110 3 2-1/4 1 1<br />

0.164 3 2-1/2 1/2 1<br />

0.164 3-1/2 3 1/2 1<br />

0.164 4 3-1/2 1/2 1<br />

ROUND ROUND OCTAGON<br />

0.045 0.060 0.060<br />

1.00 1.00 1.00<br />

NO NO NO<br />

-- -- -- -- -- -- -- -- --<br />

HAMMER (REQUIRED) HAMMER (REQUIRED) HAMMER (REQUIRED)<br />

-- -- --<br />

-- -- --<br />

NO NO BOCA, ICBO<br />

BOCA, ICBO BOCA, ICBO YES<br />

YES YES X<br />

X<br />

525


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME OLYMPIC MANUFACTURING GROUP OLYMPIC MANUFACTURING GROUP<br />

2. PRODUCT NAME OLYMPIC FASTENER STD #12 OLYMPIC FASTENER STD #12<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HARDENED CARBON STEEL STAINLESS STEEL, SPECIAL 400-SERIES BLEND<br />

6. COATING TYPE CR-10 CR-10<br />

7. SHANK TYPE THREADED THREADED<br />

8. POINT TYPE PINCH, SELF-DRILLING; GIMLET; OR TAPEX PINCH, SELF-DRILLING<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.160 1-5/8 5/8 1/2 1 0.168 1-5/8 5/8 1/2 1<br />

0.160 2-1/4 1-1/4 1/2 1 0.168 2-1/4 1-1/4 1/2 1<br />

0.160 2-7/8 1-7/8 1/2 1 0.168 2-7/8 2-3/8 1/2 1<br />

0.160 3-1/4 2-1/4 1/2 1 0.168 3-1/4 2-1/4 1/2 1<br />

0.160 3-3/4 2-3/4 1/2 1 0.168 3-3/4 2-3/4 1/2 1<br />

0.160 4-1/2 3-1/2 1/2 1 0.168 4-1/2 3-1/2 1/2 1<br />

0.160 5 4 1/2 1 0.168 5 4 1/2 1<br />

0.160 6 5 1/2 1 0.168 6 5 1/2 1<br />

0.160 7 6 1/2 1 0.168 7 6 1/2 1<br />

0.160 8 7 1 /2 1 0.168 8 7 1 /2 1<br />

11. HEAD SHAPE ROUND TRUSS, #3 PHILLIPS, OR HEX HEAD ROUND TRUSS, #3 PHILLIPS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.110 0.110<br />

Diameter 0.435 0.435<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 2 STEEL ROUND 2 STAINLESS STEEL<br />

ROUND 2 PLASTIC ROUND 3 STAINLESS STEEL<br />

ROUND 2 STAINLESS STEEL ROUND 2 PLASTIC<br />

ROUND 3 STEEL ROUND 2 PLASTIC<br />

ROUND 3 PLASTIC ROUND 3 STEEL<br />

ROUND 3 STAINLESS STEEL ROUND 3 PLASTIC<br />

ROUND 3-1/2 STEEL ROUND 3-1/2 STEEL<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL OPTIONAL<br />

Special Tool Needed (optional/required)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 531 531<br />

2-inch pine plank 735 735<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, UL, ICBO, METRO-DADE COUNTY FM, UL, ICBO, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

526


<strong>Roof</strong> Fasteners: Wood Decks<br />

OLYMPIC MANUFACTURING GROUP OLYMPIC MANUFACTURING GROUP POWERS FASTENERS, INC.<br />

OLYMPIC FASTENER HD #14 (C STEEL) OLYMPIC FASTENER HD #14 (S.STEEL) POWERS RAWL #14 DECK SCREW<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

HARDENED CARBON STEEL STAINLESS STEEL, SPECIAL 400-SERIES BLEND CASE HARDENED CARBON STEEL<br />

CR-10 CR-10 PERMA-SEAL FLUOROPOLYMER<br />

THREADED THREADED SPIRAL THREAD<br />

PINCH, SELF-DRILLING OR TAPEX PINCH, SELF-DRILLING DRILL TYPE<br />

THREADED THREADED THREADED<br />

0.190 1-1/4 3/4 1/2 1 0.190 1-1/4 3/4 1/2 1 0.238 1-5/8 1-3/8 1/4 --<br />

0.190 1-3/4 1-1/4 1/2 1 0.190 1-3/4 1-1/4 1/2 1 0.238 2-1/4 2-5/8 1/4 --<br />

0.190 2 1-1/2 1/2 1 0.190 2 1-1/2 1/2 1 0.238 2-7/8 3-1/2 1/4 --<br />

0.190 3 2-1/2 1/2 1 0.190 3 2-1/2 1/2 1 0.238 3-3/4 4 1/4 --<br />

0.190 4 3-1/2 1/2 1 0.190 4 3-1/2 1/2 1 0.238 4-1/2 4-1/4 1/4 --<br />

0.190 5 4-1/2 1/2 1 0.190 5 4-1/2 1/2 1 0.238 5 4-3/4 1/4 --<br />

0.190 6 5-1/2 1/2 1 0.190 6 5-1/2 1/2 1 0.238 6 5-3/4 1/4 --<br />

0.190 7 6-1/2 1/2 1 0.190 7 6-1/2 1/2 1 0.238 7 6-3/4 1/4 --<br />

0.190 8 7-1/2 1/2 1 0.190 8 7-1/2 1/2 1 0.238 8 7-3/4 1/4 --<br />

0.190 9 8-1/2 1/2 1 0.190 9 8-1/2 1/2 1 0.238 9 8-3/4 1/4 --<br />

0.190 10 9-1/2 1/2 1 0.190 10 9-1/2 1/2 1 0.238 10 9-3/4 1/4 --<br />

0.190 12 11-1/2 1/2 1 0.190 12 11-1/2 1/2 1 0.238 11 10-3/4 1/4 --<br />

0.190 14 13-1/2 1/2 1 0.190 14 13-1/2 1/2 1 0.238 12 11-3/4 1/4 --<br />

0.190 16 15-1/2 1/2 1 0.190 16 15-1/2 1/2 1<br />

0.190 17 16-1/2 1/2 1 0.190 17 16-1/2 1/2 1<br />

0.201 18 17-1/2 1/2 1 0.201 18 17-1/2 1/2 1<br />

0.201 20 19-1/2 1/2 1 0.201 20 19-1/2 1/2 1<br />

0.201 21 19-1/2 1/2 1 0.201 21 19-1/2 1/2 1<br />

0.201 22 21-1/2 1/2 1 0.201 22 21-1/2 1/2 1<br />

0.201 24 23-1/2 1/2 1 0.201 24 23-1/2 1/2 1<br />

ROUND TRUSS, #3 PHILLIPS ROUND TRUSS, #3 PHILLIPS PHILLIPS FLAT TRUSS HEAD #3 RECESS<br />

0.110 0.110 0.118<br />

0.435 0.435 0.448<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2 STAINLESS STEEL ROUND 2 STAINLESS STEEL ROUND BARBED 2 GALVALUME<br />

ROUND 3 STAINLESS STEEL ROUND 3 STAINLESS STEEL ROUND 3 GALVALUME<br />

ROUND 2 PLASTIC ROUND 2 PLASTIC ROUND 3 STAINLESS STEEL<br />

ROUND 2 PLASTIC ROUND 2 PLASTIC ROUND 3 PLASTIC<br />

ROUND 3 STEEL ROUND 3 STEEL<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

ROUND 3-1/2 STEEL ROUND 3-1/2 STEEL<br />

REQUIRED REQUIRED REQUIRED<br />

OPTIONAL OPTIONAL STAND-UP TOOL (OPTIONAL)<br />

590 590 730<br />

820 820 --<br />

YES YES YES<br />

FM, UL, ICBO, METRO-DADE COUNTY FM, UL, ICBO, METRO-DADE COUNTY FM<br />

YES YES YES<br />

X<br />

X<br />

527


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME POWERS FASTENERS, INC. POWERS FASTENERS, INC.<br />

2. PRODUCT NAME POWERS RAWL WOODIE POWERS RAWL #12 DECK SCREW<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

Single-Ply Membranes<br />

X<br />

5. MATERIAL TYPE ZAMAC ALLOY CASE HARDENED STEEL<br />

6. COATING TYPE GALVALUME PERMA-SEAL FLUOROPOLYMER<br />

7. SHANK TYPE TAPERED/THREADED (SPECIAL DESIGN) SPIRAL THREAD<br />

8. POINT TYPE SELF-DRILLING RICOH "S" POINT/DRILL TYPE<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.490 1-3/4 1/8 3/4 -- 0.226 1-5/8 1-3/8 1/4 --<br />

0.490 2-1/2 3/4 3/4 -- 0.226 2-1/4 2 1/4 --<br />

0.490 3-1/4 1-1/2 3/4 -- 0.226 2-7/8 2-5/8 1/4 --<br />

0.490 4 2-1/4 3/4 -- 0.226 3-1/4 3 1/4 --<br />

0.490 4-3/4 3 3/4 -- 0.226 3-3/4 3-1/2 1/4 --<br />

0.226 4-1/2 4-1/4 1/4 --<br />

0.226 5 4-3/4 1/4 --<br />

0.226 6 5-3/4 1/4 --<br />

0.226 7 6-3/4 1/4 --<br />

0.226 8 7-3/4 1/4 --<br />

11. HEAD SHAPE FLAT, SQUARE DRIVE RECESS PHILLIPS TRUSS HEAD #3 RECESS WASHER / 1/4-IN HEX HEAD<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.073 0.130 / 0.140<br />

Diameter 0.600 0.448 / 0.385<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND BARBED 2 GALVALUME ROUND BARBED 2 GALVALUME<br />

ROUND BARBED 3 GALVALUME ROUND 3 GALVALUME<br />

ROUND 3 STAINLESS STEEL<br />

ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

STAND-UP TOOL (OPTIONAL)<br />

Special Tool Needed (optional/required)<br />

SQUARE DRIVER (INCLUDED)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 591 710<br />

2-inch pine plank -- --<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM FM<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

528


<strong>Roof</strong> Fasteners: Wood Decks<br />

POWERS FASTENERS, INC. POWERS FASTENERS, INC. SENCO PRODUCTS, INC.<br />

POWERS RAWL #15 DECK SCREW POWERS RAWL SPEED-LOCK TOGGLE SENCO BASE TAPE SYSTEM<br />

U.S. U.S. U.S.<br />

X<br />

X<br />

X X X<br />

X<br />

X<br />

CASE HARDENED CARBON STEEL CARBON STEEL & STAINLESS STEEL CLASS 1 GALVANIZED STEEL<br />

PERMA-SEAL FLUOROPOLYMER PERMA-SEAL FLUOROPOLYMER (on carbon steel bolt only) SENCOTE PLASTIC POLYMER<br />

SPIRAL THREAD ANNULAR THREAD STAPLE-16 GA.<br />

RICOH "S" POINT NA DIVERGENT<br />

THREADED THREADED MECHANICALLY ATTACHED<br />

0.264 1-1/4 1 1/4 -- 0.250 5 3-1/2 1-1/2 -- 0.062 X 0.55 7/8 -- -- --<br />

0.264 2 1-3/4 1/4 -- 0.250 6 4-1/2 1-1/2 --<br />

0.264 3 2-3/4 1/4 -- 0.250 7 5-1/2 1-1/2 --<br />

0.264 4 3-3/4 1/4 -- 0.250 8 6-1/2 1-1/2 --<br />

0.264 5 4-3/4 1/4 -- 0.250 9 7-1/2 1-1/2 --<br />

0.264 6 5-3/4 1/4 -- 0.250 10 8-1/2 1-1/2 --<br />

0.264 7 6-3/4 1/4 -- 0.250 12 10-1/2 1-1/2 --<br />

0.264 8 7-3/4 1/4 -- 0.250 14 12-1/2 1-1/2 --<br />

0.264 10 9-3/4 1/4 --<br />

0.264 12 11-3/4 1/4 --<br />

0.264 14 13-3/4 1/4 --<br />

0.264 16 15-3/4 1/4 --<br />

PHILLIPS TRUSS HEAD #3 RECESS PHILLIPS FLAT HEAD #3 RECESS STAPLE<br />

0.130 0.042<br />

0.448 0.426<br />

YES YES NO<br />

YES<br />

YES<br />

ROUND BARBED 2 GALVALUME ROUND 3 GALVALUME<br />

ROUND 3 GALVALUME<br />

ROUND 3 STAINLESS STEEL<br />

ROUND 3 PLASTIC<br />

REQUIRED<br />

STAND-UP TOOL (OPTIONAL)<br />

OPTIONAL<br />

REQUIRED<br />

ROTARY DRILL WITH WOOD CUTTING BIT (REQUIRED)<br />

720 710<br />

-- --<br />

YES YES NO<br />

FM FM ICBO<br />

YES YES NO<br />

X<br />

529


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME SFS STADLER INC. SFS STADLER INC.<br />

2. PRODUCT NAME INSUL-FIXX #12-11 INSUL-FIXX #14-10<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HARDENED STEEL HARDENED STEEL<br />

6. COATING TYPE TUFF-TITE II TUFF-TITE II<br />

7. SHANK TYPE SPIRAL THREAD SPIRAL THREAD<br />

8. POINT TYPE DRILL POINT DRILL POINT<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.172 1-5/8 1-1/8 1/2 1 0.190 1-1/4 3/4 1/2 1<br />

0.172 2-1/4 1-3/4 1/2 1 0.190 2 1-1/2 1/2 1<br />

0.172 2-7/8 2-3/8 1/2 1 0.190 3 2-1/2 1/2 1<br />

0.172 3-1/4 2-3/4 1/2 1 0.190 4 3-1/2 1/2 1<br />

0.172 3-3/4 3-1/4 1/2 1 0.190 5 4-1/2 1/2 1<br />

0.172 4-1/2 4 1/2 1 0.190 6 5-1/2 1/2 1<br />

0.172 5 4-1/2 1/2 1 0.190 7 6-1/2 1/2 1<br />

0.172 6 5-1/2 1/2 1 0.190 8 7-1/2 1/2 1<br />

0.172 7 6-1/2 1/2 1 0.190 10 9-1/2 1/2 1<br />

0.172 8 7-1/2 1/2 1 0.190 12 11-1/2 1/2 1<br />

0.190 14 13-1/2 1/2 1<br />

0.190 16 15-1/2 1/2 1<br />

0.201 18 17-1/2 1/2 1<br />

0.201 20 19-1/2 1/2 1<br />

0.201 22 21-1/2 1/2 1<br />

0.201 24 23-1/2 1/2 1<br />

0.201 26 25-1/2 1/2 1<br />

11. HEAD SHAPE ROUND WITH #3 PHILLIPS TRUSS ROUND WITH #3 PHILLIPS TRUSS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.103 0.103<br />

Diameter 0.425 0.425<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 3 POLYETHYLENE ROUND 3 POLYETHYLENE<br />

ROUND 3 GALVALUME ROUND 3 GALVALUME<br />

ROUND 2 NYLON WITH GLASS<br />

ROUND 2 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 630 691<br />

2-inch pine plank 756 819<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

530


<strong>Roof</strong> Fasteners: Wood Decks<br />

SFS STADLER INC. SFS STADLER INC. SFS STADLER INC.<br />

SYSTEM ESI #14-10 SYSTEM ES L #14-10 SYSTEM ES I #12-11<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

HARDENED STEEL HARDENED STEEL HARDENED STEEL<br />

TUFF TITE II TUFF TITE II TUFF TITE II<br />

SPIRAL THREAD SPIRAL THREAD SPIRAL THREAD<br />

DRILL POINT DRILL POINT DRILL POINT<br />

THREADED THREADED THREADED<br />

0.190 2 1 1/2 1 0.190 2 1 1/2 1 0.172 2-1/4 1-3/4 1/2 1<br />

0.190 3 2 1/2 1 0.190 3 2 1/2 1 0.172 2-7/8 2-3/8 1/2 1<br />

0.190 4 3 1/2 1 0.190 4 3 1/2 1 0.172 3-1/4 2-3/4 1/2 1<br />

0.190 5 4 1/2 1 0.190 5 4 1/2 1 0.172 3-3/4 2-1/4 1/2 1<br />

0.190 6 5 1/2 1 0.190 6 5 1/2 1 0.172 4-1/2 4 1/2 1<br />

0.190 7 6 1/2 1 0.190 7 6 1/2 1 0.172 5 4-1/2 1/2 1<br />

0.190 8 7 1/2 1 0.190 8 7 1/2 1 0.172 6 5-1/2 1/2 1<br />

0.190 10 9 1/2 1 0.190 10 9 1/2 1 0.172 7 5-1/2 1/2 1<br />

0.190 12 11 1/2 1 0.190 12 11 1/2 1 0.172 8 7-1/2 1/2 1<br />

ROUND WITH #3 PHILLIPS TRUSS ROUND WITH #3 PHILLIPS TRUSS ROUND WITH #3 PHILLIPS TRUSS<br />

0.103 0.103 0.103<br />

0.425 0.425 0.425<br />

YES YES YES<br />

YES YES YES<br />

ROUND 3 POLYETHYLENE ROUND 2 NYLON WITH GLASS ROUND 3 GALVALUME<br />

REQUIRED REQUIRED REQUIRED<br />

OPTIONAL OPTIONAL OPTIONAL<br />

OPTIONAL OPTIONAL OPTIONAL<br />

691 691 630<br />

819 819 756<br />

YES YES YES<br />

FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

YES YES YES<br />

X X X<br />

531


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME SFS STADLER INC. SFS STADLER INC.<br />

2. PRODUCT NAME ISOFAST IG-M ISOFAST IW-T-M<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CARBON STEEL CARBON STEEL<br />

6. COATING TYPE TUFF TITE II TUFF TITE II<br />

7. SHANK TYPE THREADED THREADED<br />

8. POINT TYPE GIMLET GIMLET<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.236 2-1/4 1 1-1/4 1-1/4 0.196 1-5/8 1-3/4 1 1<br />

0.236 2-3/4 1-1/2 1-1/4 1-1/4 0.196 2-3/4 3/8 1 1<br />

0.236 3-1/8 1-7/8 1-1/4 1-1/4<br />

0.236 3-7/8 2-5/8 1-1/4 1-1/4<br />

0.236 4-3/4 3-1/2 1-1/4 1-1/4<br />

0.236 5-1/2 4-1/4 1-1/4 1-1/4<br />

0.236 6-1/4 5 1-1/4 1-1/4<br />

11. HEAD SHAPE 5/16 HEX HEAD COUNTERSUNK POSI-DRIVE #2<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.156 0.156<br />

Diameter 0.406 0.406<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

OVAL 3-1/4 X 1-5/8 GALVALUME OVAL 3-1/4 X 1-5/8 GALVALUME<br />

SQUARE 2-3/4 X 2-3/4 GALVALUME SQUARE 2-3/4 X 2-3/4 GALVALUME<br />

DOMED<br />

CONVEX 3-1/4 X 1-5/8 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) REQUIRED REQUIRED<br />

Special Tool Needed (optional/required) REQUIRED REQUIRED<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 545 445<br />

2-inch pine plank 1100 880<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

532


<strong>Roof</strong> Fasteners: Wood Decks<br />

SFS STADLER INC. SIMPLEX SIMPLEX<br />

EXTRA LOAD FASTENER HD ORIGINAL ROUND METAL CAP AG/RL ORIGINAL ROUND METAL CAP AG/EYD<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

HARDENED STEEL CARBON STEEL CARBON STEEL<br />

TUFF TITE II RUST-LOK ELECTRO GALVANIZED YELLOW DISHROMATE<br />

THREADED ANNULAR GROOVED ANNULAR GROOVED<br />

DRILL POINT DIAMOND DIAMOND<br />

THREADED THREADED FRICTION THREADED FRICTION<br />

0.205 1-1/4 3/4 1/2 1/2 0.106 1/2 1/16 1/4 1/2 0.106 1/2 1/16 1/4 1/2<br />

0.205 2 1 1/2 1/2 0.106 5/8 1/16 1/4 5/8 0.106 5/8 1/16 1/4 5/8<br />

0.205 3 2 1/2 1/2 0.106 3/4 1/16 1/4 5/8 0.106 3/4 1/16 1/4 5/8<br />

0.205 4 3 1/2 1/2 0.106 7/8 1/16 1/4 7/8 0.106 7/8 1/16 1/4 7/8<br />

0.205 5 4 1/2 1/2 0.106 1 1/16 1/4 1 0.106 1 1/16 1/4 1<br />

0.205 6 5 1/2 1/2 0.106 1-1/4 1/4 1/4 1 0.106 1-1/4 1/4 1/4 1<br />

0.205 8 7 1/2 1/2 0.120 1-1/2 1/2 1/4 1 0.120 1-1/2 1/2 1/4 1<br />

0.205 10 9 1/2 1/2 0.120 1-3/4 3/4 1/4 1 0.120 1-3/4 3/4 1/4 1<br />

0.205 12 11 1/2 1/2 0.120 2 1 1/4 1 0.120 2 1 1/4 1<br />

0.205 12 11 1/2 1/2 0.120 2-1/2 1-1/2 1/4 1 0.120 2-1/2 1-1/2 1/4 1<br />

0.205 14 13 1/2 1/2 0.120 3 2 1/4 1 0.120 3 2 1/4 1<br />

0.205 16 15 1/2 1/2<br />

ROUND WITH #3 PHILLIPS TRUSS ROUND ROUND<br />

0.103 0.037 0.037<br />

0.425 1.000 1.000<br />

YES NO NO<br />

YES YES YES<br />

ROUND 3 GALVALUME PARABOLIC 2 GALVALUME PARABOLIC 2 GALVALUME<br />

ROUND 2 GALVALUME PARABOLIC 3 GALVALUME PARABOLIC 3 GALVALUME<br />

REQUIRED NO NO<br />

OPTIONAL NO NO<br />

NO<br />

NO<br />

MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER<br />

885 224 224<br />

1200 190 190<br />

YES NO NO<br />

FM, METRO-DADE CONTY APA, FFN-105B APA, FFN-105B<br />

YES YES YES<br />

X X X<br />

533


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME SIMPLEX SIMPLEX<br />

2. PRODUCT NAME ORIGINAL ROUND METAL CAP AG/B ORIGINAL ROUND METAL CAP B/RL<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CARBON STEEL CARBON STEEL<br />

6. COATING TYPE BRIGHT FINISH RUST-LOK<br />

7. SHANK TYPE ANNULAR GROOVED BARBED<br />

8. POINT TYPE DIAMOND DIAMOND<br />

9. METHOD OF ATTACHMENT THREADED FRICTION FRICTION<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.106 1/2 1/16 1/4 1/2 0.106 1/2 1/16 1/4 1/2<br />

0.106 5/8 1/16 1/4 5/8 0.106 5/8 1/16 1/4 5/8<br />

0.106 3/4 1/16 1/4 5/8 0.106 3/4 1/16 1/4 5/8<br />

0.106 7/8 1/16 1/4 7/8 0.106 7/8 1/16 1/4 7/8<br />

0.106 1 1/16 1/4 1 0.106 1 1/16 1/4 1<br />

0.106 1-1/4 1/4 1/4 1 0.106 1-1/4 1/4 1/4 1<br />

0.120 1-1/2 1/2 1/4 1 0.120 1-1/2 1/2 1/4 1<br />

0.120 1-3/4 3/4 1/4 1 0.120 1-3/4 3/4 1/4 1<br />

0.120 2 1 1/4 1 0.120 2 1 1/4 1<br />

0.120 2-1/2 1-1/2 1/4 1 0.120 2-1/2 1-1/2 1/4 1<br />

0.120 3 2 1/4 1 0.120 3 2 1/4 1<br />

11. HEAD SHAPE ROUND ROUND<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.037 0.037<br />

Diameter 1.000 1.000<br />

13. PLATES<br />

Required (yes/no) NO NO<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

PARABOLIC 2 GALVALUME PARABOLIC 2 GALVALUME<br />

PARABOLIC 3 GALVALUME PARABOLIC 3 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) NO NO<br />

Installation Tool With Screw Gun (optional/required) NO NO<br />

Special Tool Needed (optional/required) NO NO<br />

Other<br />

MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 224 99<br />

2-inch pine plank 190 67<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) NO NO<br />

18. ACCEPTED BY THE FOLLOWING CODES APA, FFN-105B APA, FFN-105B<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

534


<strong>Roof</strong> Fasteners: Wood Decks<br />

SIMPLEX SIMPLEX SIMPLEX<br />

ORIGINAL ROUND METAL CAP B/EGYD ORIGINAL ROUND METAL CAP B/B INSULATION ROUND METAL CAP AG/RL<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

CARBON STEEL CARBON STEEL CARBON STEEL<br />

YELLOW DICHROMATE BRIGHT FINISH RUST-LOK<br />

BARBED BARBED ANNULAR GROOVED<br />

DIAMOND DIAMOND DIAMOND<br />

FRICTION FRICTION THREADED FRICTION<br />

0.106 1/2 1/16 1/4 1/2 0.106 1/2 1/16 1/4 1/2 0.120 3 2 1/4 1<br />

0.106 5/8 1/16 1/4 5/8 0.106 5/8 1/16 1/4 5/8 0.120 3-1/2 2-1/2 1/4 1<br />

0.106 3/4 1/16 1/4 5/8 0.106 3/4 1/16 1/4 5/8 0.120 4 3 1/4 1<br />

0.106 7/8 1/16 1/4 7/8 0.106 7/8 1/16 1/4 7/8 0.120 5 4 1/4 1<br />

0.106 1 1/16 1/4 1 0.106 1 1/16 1/4 1 0.120 6 5 1/4 1<br />

0.106 1-1/4 1/4 1/4 1 0.106 1-1/4 1/4 1/4 1 0.120 7 6 1/4 1<br />

0.120 1-1/2 1/2 1/4 1 0.120 1-1/2 1/2 1/4 1 0.120 8 7 1/4 1<br />

0.120 1-3/4 3/4 1/4 1 0.120 1-3/4 3/4 1/4 1<br />

0.120 2 1 1/4 1 0.120 2 1 1/4 1<br />

0.120 2-1/2 1-1/2 1/4 1 0.120 2-1/2 1-1/2 1/4 1<br />

0.120 3 2 1/4 1 0.120 3 2 1/4 1<br />

ROUND ROUND ROUND<br />

0.037 0.037 0.037<br />

1.000 1.000 1.000<br />

NO NO NO<br />

YES YES YES<br />

PARABOLIC 2 GALVALUME PARABOLIC 2 GALVALUME PARABOLIC 2 GALVALUME<br />

PARABOLIC 3 GALVALUME PARABOLIC 3 GALVALUME PARABOLIC 3 GALVALUME<br />

NO NO NO<br />

NO NO NO<br />

NO NO NO<br />

MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER<br />

99 99 224<br />

67 67 273<br />

NO NO NO<br />

APA, FFN-105B APA, FFN-105B APA, FFN-105B<br />

YES YES YES<br />

X X X<br />

535


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME SIMPLEX SIMPLEX<br />

2. PRODUCT NAME INSULATION ROUND METAL CAP AG/EGYD INSULATION ROUND METAL CAP AG/B<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CARBON STEEL CARBON STEEL<br />

6. COATING TYPE ELECTRO GALVANIZED YELLOW DICHROMATE BRIGHT FINISH<br />

7. SHANK TYPE ANNULAR GROOVED ANNULAR GROOVED<br />

8. POINT TYPE DIAMOND DIAMOND<br />

9. METHOD OF ATTACHMENT THREADED FRICTION THREADED FRICTION<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.120 3 2 1/4 1 0.120 3 2 1/4 1<br />

0.120 3-1/2 2-1/2 1/4 1 0.120 3-1/2 2-1/2 1/4 1<br />

0.120 4 3 1/4 1 0.120 4 3 1/4 1<br />

0.120 5 4 1/4 1 0.120 5 4 1/4 1<br />

0.120 6 5 1/4 1 0.120 6 5 1/4 1<br />

0.120 7 6 1/4 1 0.120 7 6 1/4 1<br />

0.120 8 7 1/4 1 0.120 8 7 1/4 1<br />

11. HEAD SHAPE ROUND ROUND<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.037 0.037<br />

Diameter 1.000 1.000<br />

13. PLATES<br />

Required (yes/no) NO NO<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

PARABOLIC 2 GALVALUME PARABOLIC 2 GALVALUME<br />

PARABOLIC 3 GALVALUME PARABOLIC 3 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) NO NO<br />

Installation Tool With Screw Gun (optional/required) NO NO<br />

Special Tool Needed (optional/required) NO NO<br />

Other<br />

MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 224 224<br />

2-inch pine plank 273 273<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) NO NO<br />

18. ACCEPTED BY THE FOLLOWING CODES APA, FFN-105B APA, FFN-105B<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

536


<strong>Roof</strong> Fasteners: Wood Decks<br />

SIMPLEX SIMPLEX SIMPLEX<br />

INSULATION ROUND METAL CAP B/RL INSULATION ROUND METAL CAP B/EGYD INSULATION ROUND METAL CAP B/B<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

CARBON STEEL CARBON STEEL CARBON STEEL<br />

RUST-LOK ELECTRO GALVANIZED YELLOW DICHROMATE BRIGHT FINISH<br />

BARBED BARBED BARBED<br />

DIAMOND DIAMOND DIAMOND<br />

FRICTION FRICTION FRICTION<br />

0.120 3 2 1/4 1 0.120 3 2 1/4 1 0.120 3 2 1/4 1<br />

0.120 3-1/2 2-1/2 1/4 1 0.120 3-1/2 2-1/2 1/4 1 0.120 3-1/2 2-1/2 1/4 1<br />

0.120 4 3 1/4 1 0.120 4 3 1/4 1 0.120 4 3 1/4 1<br />

0.120 5 4 1/4 1 0.120 5 4 1/4 1 0.120 5 4 1/4 1<br />

0.120 6 5 1/4 1 0.120 6 5 1/4 1 0.120 6 5 1/4 1<br />

0.120 7 6 1/4 1 0.120 7 6 1/4 1 0.120 7 6 1/4 1<br />

0.120 8 7 1/4 1 0.120 8 7 1/4 1 0.120 8 7 1/4 1<br />

ROUND ROUND ROUND<br />

0.037 0.037 0.037<br />

1.000 1.000 1.000<br />

NO NO NO<br />

YES YES YES<br />

PARABOLIC 2 GALVALUME PARABOLIC 2 GALVALUME PARABOLIC 2 GALVALUME<br />

PARABOLIC 3 GALVALUME PARABOLIC 3 GALVALUME PARABOLIC 3 GALVALUME<br />

NO NO NO<br />

NO NO NO<br />

NO NO NO<br />

MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER<br />

99 99 99<br />

92 92 92<br />

NO NO NO<br />

APA, FFN-105B APA, FFN-105B APA, FFN-105B<br />

YES YES YES<br />

X X X<br />

537


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME SIMPLEX SIMPLEX<br />

2. PRODUCT NAME INSULATION ROUND METAL CAP B/EGYD SQUARE HEAD METAL CAP B/B<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CARBON STEEL CARBON STEEL<br />

6. COATING TYPE ELECTRO GALVANIZED YELLOW DICHROMATE BRIGHT FINISH<br />

7. SHANK TYPE BARBED BARBED<br />

8. POINT TYPE DIAMOND DIAMOND<br />

9. METHOD OF ATTACHMENT FRICTION FRICTION<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.106 3/4 1/16 1/4 3/4 0.106 3/4 1/16 1/4 3/4<br />

0.106 7/8 1/16 1/4 7/8 0.106 7/8 1/16 1/4 7/8<br />

0.106 1 1/16 1/4 1 0.106 1 1/16 1/4 1<br />

0.106 1-1/4 1/4 1/4 1 0.106 1-1/4 1/4 1/4 1<br />

0.106 1-1/2 1/2 1/4 1 0.106 1-1/2 1/2 1/4 1<br />

0.106 1-3/4 3/4 1/4 1 0.106 1-3/4 3/4 1/4 1<br />

11. HEAD SHAPE ROUND ROUND<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.037 0.037<br />

Diameter 1.000 1.000<br />

13. PLATES<br />

Required (yes/no) NO NO<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

PARABOLIC 2 GALVALUME PARABOLIC 2 GALVALUME<br />

PARABOLIC 3 GALVALUME PARABOLIC 3 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) NO NO<br />

Installation Tool With Screw Gun (optional/required) NO NO<br />

Special Tool Needed (optional/required) NO NO<br />

Other<br />

MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 99 99<br />

2-inch pine plank 113 113<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) NO NO<br />

18. ACCEPTED BY THE FOLLOWING CODES APA, FFN-105B APA, FFN-105B<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

538


<strong>Roof</strong> Fasteners: Wood Decks<br />

SIMPLEX SIMPLEX SIMPLEX<br />

ECONOMY ROUND METAL CAP B/B FLEX-CAP PLASTIC CAP AG/RL FLEX-CAP PLASTIC CAP AG/EGYD<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

CARBON STEEL<br />

CARBON STEEL/HIGH DENSITY POLYTHEYLENE PLASTIC CARBON STEEL/HIGH DENSITY POLYETHYLENE PLASTIC<br />

BRIGHT FINISH RUST-LOK ELECTRO GALVANIZED YELLOW DICHROMATE<br />

BARBED ANNULAR GROOVED ANNULAR GROOVED<br />

DIAMOND DIAMOND DIAMOND<br />

FRICTION THREADED FRICTION THREADED FRICTION<br />

0.106 1/2 1/16 1/4 1/2 0.099 3/4 1/16 1/4 3/4 0.099 3/4 1/16 1/4 3/4<br />

0.106 5/8 1/16 1/4 5/8 0.099 7/8 1/16 1/4 7/8 0.099 7/8 1/16 1/4 7/8<br />

0.106 3/4 1/16 1/4 5/8 0.099 1 1/16 1/4 1 0.099 1 1/16 1/4 1<br />

0.106 7/8 1/16 1/4 7/8 0.099 1-1/4 1/4 1/4 1 0.099 1-1/4 1/4 1/4 1<br />

0.106 1 1/16 1/4 1 0.099 1-1/2 1/2 1/4 1 0.099 1-1/2 1/2 1/4 1<br />

0.106 1-1/4 1/4 1/4 1 0.099 1-3/4 3/4 1/4 1 0.099 1-3/4 3/4 1/4 1<br />

0.120 1-1/2 1/2 1/4 1 0.106 2 1 1/4 1 0.106 2 1 1/4 1<br />

0.120 1-3/4 3/4 1/4 1 0.106 2-1/2 1-1/2 1/4 1 0.106 2-1/2 1-1/2 1/4 1<br />

0.120 2 1 1/4 1 0.106 3 2 1/4 1 0.106 3 2 1/4 1<br />

0.120 2-1/2 1-1/2 1/4 1<br />

0.120 3 2 1/4 1<br />

ROUND ROUND ROUND<br />

0.037 0.125 0.125<br />

1.000 1.000 1.000<br />

NO NO NO<br />

YES YES YES<br />

PARABOLIC 2 GALVALUME PARABOLIC 2 GALVALUME PARABOLIC 2 GALVALUME<br />

PARABOLIC 3 GALVALUME PARABOLIC 3 GALVALUME PARABOLIC 3 GALVALUME<br />

NO NO NO<br />

NO NO NO<br />

NO NO NO<br />

MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER<br />

99 72 72<br />

92 72 72<br />

NO NO NO<br />

APA, FFN-105B APA, FFN-105B APA, FFN-105B<br />

YES YES YES<br />

X X X<br />

539


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME SIMPLEX SIMPLEX<br />

2. PRODUCT NAME FLEX-CAP PLASTIC CAP AG/B COIL ROOFING NAILS<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CARBON STEEL/HIGH DENSITY POLYETHYLENE PLASTIC CARBON STEEL<br />

6. COATING TYPE BRIGHT FINISH ELECTRO GALVANIZED<br />

7. SHANK TYPE ANNULAR GROOVED SMOOTH<br />

8. POINT TYPE DIAMOND DIAMOND<br />

9. METHOD OF ATTACHMENT THREADED FRICTION FRICTION<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.099 3/4 1/16 1/4 3/4 0.135 7/8 1/16 1/4 7/8<br />

0.099 7/8 1/16 1/4 7/8 0.135 1 1/8 1/4 1<br />

0.099 1 1/16 1/4 1 0.135 1-1/4 1/4 1/4 1<br />

0.099 1-1/4 1/4 1/4 1 0.135 1-1/2 1/2 1/4 1<br />

0.099 1-1/2 1/2 1/4 1 0.135 1-3/4 3/4 1/4 1<br />

0.099 1-3/4 3/4 1/4 1<br />

0.106 2 1 1/4 1<br />

0.106 2-1/2 1-1/2 1/4 1<br />

0.106 3 2 1/4 1<br />

11. HEAD SHAPE ROUND ROUND<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.125 0.037<br />

Diameter 1.000 0.250<br />

13. PLATES<br />

Required (yes/no) NO --<br />

Available From Manufacturer (yes/no) YES --<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

PARABOLIC 2 GALVALUME ROUND 1-3 GALVANIZED<br />

PARABOLIC 3 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) NO NO<br />

Installation Tool With Screw Gun (optional/required) NO NO<br />

Special Tool Needed (optional/required) NO ALL BRANDS OF PNEUMATIC NAIL GUNS<br />

Other<br />

MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 72 60<br />

2-inch pine plank 72 60<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) NO NO<br />

18. ACCEPTED BY THE FOLLOWING CODES APA, FFN-105B NONE<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES X<br />

20. SEE APPENDIX IF CHECKED X<br />

NA = not applicable<br />

540


<strong>Roof</strong> Fasteners: Wood Decks<br />

TRU-FAST CORPORATION TRU-FAST CORPORATION TRU-FAST CORPORATION<br />

HD DRILL POINT STAINLESS STEEL TP DP<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

STAINLESS STEEL (TRIMRITE ALLOY #S-42010) CARBON STEEL C-1022 CARBON STEEL C-1022<br />

NA TRU-KOTE (FLUOROCARBON PAINT) TRU-KOTE (FLUOROCARBON PAINT)<br />

THREADED THREADED THREADED<br />

DOUBLE FLUTE SELF-DRILLING GIMLET DOUBLE FLUTE SELF-DRILLING<br />

THREADED THREADED THREADED<br />

0.180 1-1/2 1 1 1 0.150 1-5/8 5/8 1 1 0.160 1-5/8 5/8 1 1<br />

0.180 2 1-1/2 1 1 0.150 2-1/4 1-1/4 1 1 0.160 2-1/4 1-1/4 1 1<br />

0.180 3 2-1/2 1 1 0.150 2-7/8 1-7/8 1 1 0.160 2-7/8 1-7/8 1 1<br />

0.180 4 3-1/2 1 1 0.150 3-3/4 2-3/4 1 1 0.160 3-1/4 2-1/4 1 1<br />

0.180 5 4-1/2 1 1 0.150 4-1/2 3-1/4 1 1 0.160 3-3/4 2-3/4 1 1<br />

0.180 6 5-1/2 1 1 0.150 5 4 1 1 0.160 4-1/2 3-1/4 1 1<br />

0.180 7 6-1/2 1 1 0.150 6 5 1 1 0.160 5 4 1 1<br />

0.180 8 7-1/2 1 1 0.160 6 5 1 1<br />

0.180 10 9-1/2 1 1 0.160 7 6 1 1<br />

0.180 12 11-1/2 1 1 0.160 8 7 1 1<br />

TRUSS #3 PHILLIPS TRUSS #3 PHILLIPS TRUSS #3 PHILILPS<br />

0.105 0.110 0.105<br />

0.440 0.390 0.440<br />

YES -- --<br />

YES -- --<br />

ROUND 2 GALVALUME ROUND 2 GALVALUME ROUND 2 GALVALUME<br />

ROUND 2.4 GALVALUME ROUND 2.4 GALVALUME ROUND 2.4 GALVALUME<br />

ROUND 3 GALVALUME ROUND 3 GALVALUME ROUND 3 GALVALUME<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

REQUIRED REQUIRED REQUIRED<br />

OPTIONAL OPTIONAL OPTIONAL<br />

495 636 566<br />

517 938 1248<br />

YES YES YES<br />

FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

YES YES YES<br />

541


<strong>Roof</strong> Fasteners: Wood Decks<br />

1. COMPANY NAME TRU-FAST CORPORATION U.S. INTEC<br />

2. PRODUCT NAME HD (HEAVY DUTY) #14 DRILL-TEC ii #12<br />

3. COUNTRY OF MANUFACTURE U.S. U.S<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CARBON STEEL C-1022 CARBON STEEL<br />

6. COATING TYPE TRU-KOTE (FLUOROCARBON PAINT) FLUOROPOLYMER PAINT<br />

7. SHANK TYPE THREADED THREADED<br />

8. POINT TYPE DOUBLE FLUTE SELF-DRILLING THREADED, SELF-TAPPING<br />

9. METHOD OF ATTACHMENT THREADS MECHANICAL<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / PLYWOOD DECK<br />

PENETRATION (inches) / WOOD DECK PENETRATION<br />

(inches)<br />

0.180 1-1/2 1/2 1 1 0.167 1-5/8 5/8 1 1<br />

0.180 2 1 1 1 0.167 2-1/4 1-1/4 1 1<br />

0.180 3 2 1 1 0.167 2-7/8 1-7/8 1 1<br />

0.180 4 3 1 1 0.167 3-3/4 2-3/4 1 1<br />

0.180 5 4 1 1 0.167 4-1/2 3-1/2 1 1<br />

0.180 6 5 1 1 0.167 5 4 1 1<br />

0.180 7 6 1 1 0.167 6 5 1 1<br />

0.180 8 7 1 1 0.167 7 6 1 1<br />

0.180 10 9 1 1 0.167 8 7 1 1<br />

0.180 12 11 1 1<br />

11. HEAD SHAPE TRUSS #3 PHILLIPS HEX OR TRUSS #3 PHILLIPS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.105 0.110<br />

Diameter 0.440 0.391<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 2 GALVALUME ROUND 2.7 GALVALUME<br />

ROUND 2.4 GALVALUME ROUND 3 PLASTIC<br />

ROUND 3 GALVALUME HEX 2.7 GALVALUME<br />

ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL OPTIONAL<br />

Special Tool Needed (optional/required)<br />

OPTIONAL<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3/4-inch plywood 495 636<br />

2-inch pine plank 517 938<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I WOOD ROOF (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

542


<strong>Roof</strong> Fasteners: Wood Decks<br />

U.S. INTEC<br />

DRILL TEC II #14<br />

U.S<br />

X<br />

X<br />

X<br />

CARBON STEEL<br />

FLUOROPOLYMER PAINT<br />

THREADED<br />

THREADED, SELF-TAPPING<br />

MECHANICAL<br />

U.S. INTEC<br />

DRILL TEC II #15 (HIGH STRENGTH)<br />

U.S<br />

X<br />

X<br />

X<br />

CARBON STEEL<br />

FLUOROPOLYMER PAINT<br />

THREADED<br />

THREADED, SELF-TAPPING<br />

MECHANICAL<br />

0.180 1-1/4 1/4 1 0.204 1-1/4 1/4 1<br />

0.180 1-5/8 5/8 1 0.204 2 1 1<br />

O.180 2-1/4 1-1/4 1 0.204 3 2 1<br />

0.180 2-7/8 1-7/8 1 0.204 4 3 1<br />

0.180 3-1/4 2-1/4 1 0.204 5 4 1<br />

0.180 3-3/4 2-3/4 1 0.204 6 5 1<br />

0.180 4-1/2 3-1/2 1 0.204 7 6 1<br />

0.180 5 4 1 0.204 8 7 1<br />

0.180 6 5 1 0.204 10 9 1<br />

0.180 7 6 1 0.204 12 11 1<br />

0.180 8 7 1 0.204 14 13 1<br />

0.180 10 9 1 0.204 16 15 1<br />

0.180 12 11 1 0.204 18 19 1<br />

0.204 20 19 1<br />

0.204 22 21 1<br />

0.204 24 23 1<br />

0.204 26 25 1<br />

TRUSS #3 PHILLIPS<br />

TRUSS #3 PHILLIPS<br />

0.118 0.130<br />

0.448 0.448<br />

YES<br />

YES<br />

YES<br />

YES<br />

ROUND 2.7 GALVALUME ROUND 2.5 GALVALUME<br />

ROUND 3 PLASTIC HEX 2.7 GALVALUME<br />

HEX 2.7 GALVALUME<br />

REQUIRED<br />

OPTIONAL<br />

OPTIONAL<br />

REQUIRED<br />

OPTIONAL<br />

OPTIONAL<br />

938<br />

YES<br />

FM, METRO-DADE COUNTY<br />

YES<br />

YES<br />

FM, METRO-DADE COUNTY<br />

YES<br />

543


<strong>Roof</strong> Fasteners: Concrete Decks<br />

1. COMPANY NAME CARLISLE SYNTEC CARLISLE SYNTEC INCORPORATED<br />

2. PRODUCT NAME HP FASTENER HP CONCRETE SPIKE<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CARBON STEEL CARBON STEEL<br />

6. COATING TYPE EPOXY ELECTRODEPOSITION EPOXY ELECTRODEPOSITION<br />

7. SHANK TYPE SINGLE LEAD, BUTTRESS THREAD --<br />

8. POINT TYPE NA NA<br />

9. METHOD OF ATTACHMENT THREADED SHANK COMPRESSION<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.240 1-1/2 1/4 1-1/4<br />

0.180 1-3/4 1/2 1-1/4 0.240 2 3/4 1-1/4<br />

0.180 2-1/4 1 1-1/4 0.240 2-1/2 1-1/4 1-1/4<br />

0.180 2-3/4 1-1/2 1-1/4 0.240 3 1-3/4 1-1/4<br />

0.180 3-1/4 2 1-1/4 0.240 3-1/2 2-1/4 1-1/4<br />

0.180 4-1/4 3 1-1/4 0.240 4 2-3/4 1-1/4<br />

0.180 5 3-3/4 1-1/4 0.240 4-1/2 3-1/4 1-1/4<br />

0.180 6 4-3/4 1-1/4 0.240 5 3-3/4 1-1/4<br />

0.240 5-1/2 4-1/4 1-1/4<br />

0.240 6 4-3/4 1-1/4<br />

0.240 6-1/2 5-1/4 1-1/4<br />

0.240 7 5-3/4 1-1/4<br />

0.240 7-1/2 6-1/4 1-1/4<br />

0.240 8 6-3/4 1-1/4<br />

0.240 8-1/2 7-1/4 1-1/4<br />

0.240 9 7-3/4 1-1/4<br />

0.240 9-1/2 8-1/4 1-1/4<br />

0.240 10 8-3/4 1-1/4<br />

0.240 10-1/2 9-1/4 1-1/4<br />

0.240 11 9-3/4 1-1/4<br />

0.240 12 10-3/4 1-1/4<br />

0.240 13 11-3/4 1-1/4<br />

0.240 12 10-3/4 1-1/4<br />

0.240 12 10-3/4 1-1/4<br />

0.240 12 10-3/4 1-1/4<br />

11. HEAD SHAPE WAFER TRUSS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.150 0.110<br />

Diameter 0.430 0.440<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

SQUARE W/ROUNDED<br />

SQUARE W/ROUNDED<br />

CORNERS 2-7/8 GALVALUME CORNERS 2-7/8 GALVALUME<br />

ROUND 2 PLASTIC ROUND 2 GALVALUME<br />

ROUND 2 GALVALUME ROUND 2-3/8 GALVALUME<br />

ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

SDS SPIKE HAMMER (OPTIONAL)<br />

Other<br />

HAMMER (REQURIED)<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3,000 PSI AGED 28 DAYS) -- --<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I CONCRETE ROOF<br />

CONSTRUCTION (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM FM<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

544


<strong>Roof</strong> Fasteners: Concrete Decks<br />

CARLISLE SYNTEC INC. CELOTEX CORP. CELOTEX CORP.<br />

HD 14-10 FASTENER ANCHORBOND #14 ANCHORBOND #15 HEAVY DUTY<br />

U.S.S<br />

U.S.<br />

X X X<br />

X<br />

X<br />

X X X<br />

CARBON STEEL HARDENED CARBON STEEL HARDENED CARBON STEEL<br />

EPOXY ELECTRODEPOSITION ORGANIC FLUOROPOLYMERS ORGANIC FLUOROPOLYMERS<br />

SINGLE LEAD, V THREAD SPIRAL THREAD SPIRAL THREAD<br />

SINGLE EDGE DRILL POINT SELF-DRILLING SELF-DRILLING<br />

THREADED THREADED THREADED<br />

.0190 2 1 1 0.238 1-1/4 1/4 1 0.238 1-1/4 1/4 1<br />

.0190 3 2 1 0.238 1-5/8 5/8 1 0.238 2 1 1<br />

.0190 4 3 1 0.238 1-7/8 1-1/4 1 0.238 3 2 1<br />

.0190 5 4 1 0.238 2-7/8 1-7/8 1 0.238 4 3 1<br />

.0190 6 5 1 0.238 3-1/4 2-1/4 1 0.238 5 4 1<br />

.0190 7 6 1 0.238 3-3/4 2-3/4 1 0.238 6 5 1<br />

.0190 8 7 1 0.238 4-1/2 3-1/2 1 0.238 7 5 1<br />

.0190 9 8 1 0.238 5 4 1 0.238 8 7 1<br />

.0190 10 9 1 0.238 6 5 1 0.238 10 9 1<br />

.0190 11 10 1 0.238 7 5 1 0.238 12 11 1<br />

0.238 7 6 1 0.238 14 13 1<br />

0.238 16 15 1<br />

TRUSS #3 PHILLIPS FLAT TRUSS #3 PHILLIPS FLAT TRUSS<br />

0.115 0.109 0.109<br />

0.435 0.438 0.438<br />

YES YES YES<br />

YES YES YES<br />

SQUARE W/ROUNDED HEXAGONAL 2-7/8 STAINLESS STEEL HEXAGONAL 2-7/8 STAINLESS STEEL<br />

CORNERS 2-7/8 GALVALUME HEXAGONAL 2-7/8 GALVALUME HEXAGONAL 2-7/8 GALVALUME<br />

ROUND 2 PLASTIC HEXAGONAL 3 PLASTIC ROUND 2 GALVALUME<br />

ROUND 2 GALVALUME HEXAGONAL 2 GALVALUME<br />

ROUND 3 PLASTIC<br />

ROUND 2-3/8 GALVALUME<br />

REQUIRED REQUIRED REQUIRED<br />

HAMMER DRILL (REQUIRED)<br />

HAMMER DRILL (REQUIRED)<br />

-- 959 935<br />

YES YES YES<br />

FM FM FM<br />

YES YES YES<br />

545


<strong>Roof</strong> Fasteners: Concrete Decks<br />

1. COMPANY NAME CONSTRUCTION FASTENERS, INC. CONSTRUCTION FASTENERS, INC.<br />

2. PRODUCT NAME DEKFAST #14 DEKFAST #15 HI-STRENGTH<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HARDENED CARBON STEEL HARDENED CARBON STEEL<br />

6. COATING TYPE ORGANIC ORGANIC<br />

7. SHANK TYPE SPIRAL THREAD SPIRAL THREAD<br />

8. POINT TYPE SELF-DRILLING SELF-DRILLING<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.238 1- 1/4 1/4 1 0.264 1-1/4 1/4 1<br />

0.238 1- 5/8 5/8 1 0.264 2 1 1<br />

0.238 2-1/4 1-1/4 1 0.264 3 2 1<br />

0.238 2-7/8 1-7/8 1 0.264 4 3 1<br />

0.238 3-1/4 2-1/4 1 0.264 5 4 1<br />

0.238 3-3/4 2-3/4 1 0.264 6 5 1<br />

0.238 4-1/2 3-1/2 1 0.264 7 6 1<br />

0.238 5 4 1 0.264 8 7 1<br />

0.238 6 5 1 0.264 10 9 1<br />

0.238 7 6 1 0.264 12 11 1<br />

0.238 8 7 1 0.264 14 13 1<br />

0.238 10 9 1 0.264 16 15 1<br />

0.238 12 11 1 0.264 18 17 1<br />

0.264 20 19 1<br />

0.264 22 21 1<br />

0.264 24 23 1<br />

0.264 26 25 1<br />

11. HEAD SHAPE #3 PHILLIPS FLAT TRUSS #3 PHILLIPS TRUSS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.118 0.130<br />

Diameter 0.448 0.448<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

HEXAGONAL 2-7/8 GALVALUME HEXAGONAL 2-7/8 GALVALUME<br />

HEXAGONAL 3 PLASTIC ROUND 2 GALVALUME<br />

ROUND 2 GALVALUME ROUND 2-1/2 GALVALUME<br />

ROUND 2 NYLON ROUND 3 PLASTIC<br />

ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

Other HAMMER DRILL (REQUIRED) HAMMER DRILL (REQUIRED)<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3,000 PSI AGED 28 DAYS) 784 850<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I CONCRETE ROOF<br />

CONSTRUCTION (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

546


<strong>Roof</strong> Fasteners: Concrete Decks<br />

CONSTRUCTION FASTENERS, INC. DURO LAST INC. DURO LAST INC.<br />

DEKSPIKE DUR0-LAST CONCRETE SCREW DURO LAST CONCRETE NAIL<br />

U.S. U.S.<br />

X X X<br />

X<br />

X X X<br />

HARDENED CARBON STEEL CARBON STEEL C-1022 HARDENED CARBON STEE<br />

ORGANIC FLUOROPOLYMER PAINT CR-10 FLUOROCARBON<br />

FORMED SHANK THREADED SPIRAL FLUTED<br />

N/A DIAMOND<br />

FRICTION THREADED THREADED<br />

0.250 1-1/4 1/8 1-1/8 0.180 1-1/4 1/4 1 0.215 1-1/8 1/8 1<br />

0.250 1-1/2 1/4 1-1/4 0.180 1-3/4 3/4 1 0.215 1-1/2 1/2 1<br />

0.250 2 3/4 1-1/4 0.180 2-1/4 1-1/4 1 0.215 2 1 1<br />

0.250 2-1/2 1-1/4 1-1/4 0.180 2-3/4 1-3/4 1 0.215 2-1/2 1-1/2 1<br />

0.250 3 1-3/4 1-1/4 0.180 3-1/4 2-1/4 1 0.215 3 2 1<br />

0.250 3-1/2 2-1/4 1-1/4 0.180 3-3/4 2-3/4 1 0.215 3-1/2 2-1/2 1<br />

0.250 4 2-3/4 1-1/4 0.180 4-1/4 3-1/4 1 0.215 4 3 1<br />

0.250 4-1/2 3-1/4 1-1/4 0.180 5 3-3/4 1 0.215 4-1/2 3-1/2 1<br />

0.250 5 3-3/4 1-1/4 0.180 6 5 1 0.215 5 4 1<br />

0.250 5-1/2 4-1/4 1-1/4 0.180 6-1/2 5-1/2 1 0.215 5-1/2 4-1/2 1<br />

0.250 6 4-3/4 1-1/4 0.180 7 6 1 0.215 6 5 1<br />

0.250 6-1/2 5-1/4 1-1/4 0.180 7-1/2 6-1/2 1 0.215 6-1/2 5-1/2 1<br />

0.250 7 5-3/4 1-1/4 0.180 8 7 1 0.215 7 6 1<br />

0.250 7-1/2 6-1/4 1-1/4 0.180 9 8 1 0.215 7-1/2 6-1/2 1<br />

0.250 8 6-3/4 1-1/4 0.180 10 9 1 0.215 8 7 1<br />

0.250 9 7-3/4 1-1/4 0.180 11 10 1<br />

0.250 10 8-3/4 1-1/4 0.890 12 11 1<br />

0.250 11 9-3/4 1-1/4<br />

0.250 12 10-3/4 1-1/4<br />

0.250 13 11-3/4 1-1/4<br />

0.250 14 12-3/4 1-1/4<br />

TRUSS # 3 SQUARE DRIVE TRUSS HEAD TRUSS<br />

0.120 0.118 0.103<br />

0.500 0.445 0.438<br />

YES YES YES<br />

YES YES YES<br />

HEXAGONAL 2-7/8 GALVALUME ROUND (SEAM) 2 POLYCARBONATE ROUND 2 POLYCARBONATE<br />

ROUND 2 GALVALUME ROUND (SEAM) 2 GALVALUME<br />

ROUND (INSUL) 3 PERLITE<br />

SQUARE (INSUL) 3 GALAVLUME<br />

N/A REQUIRED REQUIRED<br />

N/A OPTIONAL OPTIONAL<br />

HAMMER DRILL / HAMMER<br />

HAMMER DRILL<br />

613 1285<br />

YES YES YES<br />

FM, METRO-DADE COUNTY FM, ICBO, BOCA, SBCCI, METRO-DADE CNTY FM, ICBO, BOCA, SBCCI<br />

YES YES YES<br />

547


<strong>Roof</strong> Fasteners: Concrete Decks<br />

1. COMPANY NAME FIRESTONE BUILDING PRODUCTS FIRESTONE BUILDING PRODUCTS<br />

2. PRODUCT NAME FIRESTONE HEAVY DUTY FIRESTONE CONRETE DRIVE<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE SAE 1022, HEAT TREATED 1038-HARDENED STEEL<br />

6. COATING TYPE EPOXY EPOXY<br />

7. SHANK TYPE BUTTRESS THREAD SHANK COMPRESSION<br />

8. POINT TYPE DRILL POINT<br />

9. METHOD OF ATTACHMENT THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.264 1-1/4 1/4 1 0.250 1-1/2 1/4 1-1/4<br />

0.264 2 1 1 0.250 2 3/4 1-1/4<br />

0.264 3 2 1 0.250 2-1/2 1-1/4 1-1/4<br />

0.264 4 3 1 0.250 3 1-3/4 1-1/4<br />

0.264 5 4 1 0.250 3-1/2 2-1/4 1-1/4<br />

0.264 6 5 1 0.250 4 2-3/4 1-1/4<br />

0.264 7 6 1 0.250 4-1/2 3-1/4 1-1/4<br />

0.264 8 7 1 0.250 5 3-3/4 1-1/4<br />

0.264 10 9 1 0.250 5-1/2 4-1/4 1-1/4<br />

0.264 12 11 1 0.250 6 4-3/4 1-1/4<br />

0.264 14 13 1 0.250 6-1/2 5-1/4 1-1/4<br />

0.250 7 5-3/4 1-1/4<br />

0.250 7-1/2 6-1/4 1-1/4<br />

0.250 8 6-3/4 1-1/4<br />

11. HEAD SHAPE ROUND MUSHROOM #3 PHILLIPS NAIL-TYPE<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.110 0.110<br />

Diameter 0.437 0.422<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

HEX<br />

HEX<br />

(INSULATION) 2-7/8 GALVALUME (INSULATION) 2-7/8 GALVALUME<br />

ROUND<br />

ROUND<br />

(IN-SEAM) 2 GALVALUME (IN-SEAM) 2 GALVALUME<br />

ROUND<br />

ROUND<br />

(IN-SEAM) 2-3/8 GALVALUME (IN-SEAM) 2-3/8 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

SDS SPIKE DRIVER (OPTIONAL)<br />

Other HAMMER DRILL HAMMER (REQUIRED)<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3,000 PSI AGED 28 DAYS) 810 1000<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I CONCRETE ROOF<br />

CONSTRUCTION (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, ICBO, UL, SBCCI FM, ICBO, UL, SBCCI<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

548


<strong>Roof</strong> Fasteners: Concrete Decks<br />

GAF MATERIALS CORP. GAF MATERIALS CORP. GAF MATERIALS CORP.<br />

GAFTITE CD-10/EVERUARD SPIKE FLUTED CONCRETE NAIL GAFTITE #140-10 (C. STEEL)<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

HARDENED CARBON STEEL HARDEND CARBON STEEL HARDENED CARBON STEEL<br />

CR-10 FLUOROCARBON CR-1O FLUOROCARBO CR-10 FLUOROCARBON<br />

SPIRAL FLUTED<br />

THREADED<br />

DIAMOND STARTER POINT DIAMOND PINCH, SELF-DRILLING<br />

SHANK EXPANSION FRICTION THREADED<br />

0.215 2 1 1 0.215 1-1/8 1/8 1 0.190 1-1/4 1/4 1<br />

0.215 2-1/2 1-1/2 1 0.215 1-1/2 1/2 1 0.190 1-3/4 3/4 1<br />

0.215 3 2 1 0.215 2 1 1 0.190 2 1 1<br />

0.215 3-1/2 2-1/2 1 0.215 2-1/2 1-1/2 1 0.190 3 2 1<br />

0.215 4 3 1 0.215 3 2 1 0.190 4 3 1<br />

0.215 4-1/2 3-1/2 1 0.215 3-1/2 2-1/2 1 0.190 5 4 1<br />

0.215 5 4 1 0.215 4 3 1 0.190 6 5 1<br />

0.215 5-1/2 4-1/2 1 0.215 4-1/2 3-1/2 1 0.190 7 6 1<br />

0.215 6 5 1 0.215 5 4 1 0.190 8 7 1<br />

0.215 6-1/2 5-1/2 1 0.215 5-1/2 4-1/2 1 0.190 9 8 1<br />

0.215 7 6 1 0.215 6 5 1 0.190 10 9 1<br />

0.215 7-1/2 6-1/2 1 0.215 6-1/2 5-1/2 1 0.190 11 10 1<br />

0.215 8 7 1 0.215 7 6 1 0.190 12 11 1<br />

0.215 8-1/2 7-1/2 1 0.215 7-1/2 6-1/2 1 0.190 14 13 1<br />

0.215 9 8 1 0.215 8 7 1 0.190 16 15 1<br />

0.215 9-1/2 8-1/2 1 0.190 17 16 1<br />

0.215 10 9 1 0.190 18 17 1<br />

0.215 10-1/2 9-1/2 1 0.190 20 19 1<br />

0.215 11 10 1 0.190 21 20 1<br />

0.215 11-1/2 10-1/2 1 0.190 22 21 1<br />

0.215 12 11 1 0.190 24 23 1<br />

ROUND ROUND ROUND TRUSS, #3 PHILLIPS<br />

0.105 0.125 0.110<br />

0.435 0.410 0.435<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2 STEEL ROUND 2 STEEL ROUND 2 STEEL<br />

ROUND 2 PLASTIC ROUND 2 PLASTIC ROUND 2 PLASTIC<br />

ROUND 2 STAINLESS STEEL ROUND 2 STAINLESS STEEL ROUND 2 STAINLESS STEEL<br />

ROUND 3 STEEL ROUND 3 STEEL ROUND 3 STEEL<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

ROUND 3 STAINLESS STEEL ROUND 3 STAINLESS STEEL ROUND 3 STAINLESS STEEL<br />

REQUIRED<br />

OPTIONAL<br />

HAMMER DRILL HAMMER DRILL HAMMER DRILL (REQUIRED)<br />

1164 600 800<br />

YES YES YES<br />

FM, UL, ICBO, METRO-DADE COUNTY FM, UL, ICBO, METRO-DADE COUNTY FM, UL, ICBO, METRO-DADE COUNTY<br />

YES YES YES<br />

549


<strong>Roof</strong> Fasteners: Concrete Decks<br />

1. COMPANY NAME ITW BUILDEX ITW BUILDEX<br />

2. PRODUCT NAME #14 ROOFGRIP KING-CON<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HARDENED CARBON STEEL HARDENED CARBON STEEL<br />

6. COATING TYPE CLIMASEAL CLIMASEAL<br />

7. SHANK TYPE MODIFIED STANDARD THREAD PARTIALLY SPIRAL FLUTED<br />

8. POINT TYPE X-POINT NAIL<br />

9. METHOD OF ATTACHMENT THREADED FRICTION<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.245 1-1/2 1/2 1 0.250 1-1/8 1/8 1-1/4<br />

0.245 2 1 1 0.250 1-1/2 1/4 1-1/4<br />

0.245 3 2 1 0.250 2 3/4 1-1/4<br />

0.245 4 3 1 0.250 2-1/2 1-1/4 1-1/4<br />

0.245 5 4 1 0.250 3 1-3/4 1-1/4<br />

0.245 6 5 1 0.250 3-1/2 2-1/4 1-1/4<br />

0.245 7 6 1 0.250 4 2-3/4 1-1/4<br />

0.245 8 7 1 0.250 4-1/2 3-1/4 1-1/4<br />

0.250 5 3-3/4 1-1/4<br />

0.250 5-1/2 4-1/4 1-1/4<br />

0.250 6 4-3/4 1-1/4<br />

0.250 7 5-3/4 1-1/4<br />

0.250 8 6-3/4 1-1/4<br />

0.250 9 7-3/4 1-1/4<br />

0.250 10 8-3/4 1-1/4<br />

11. HEAD SHAPE #3 PHILLIPS PAN HEAD ROUND FLAT HEAD<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.118 0.100<br />

Diameter 0.448 0.440<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

SQUARE 3 X 3 GALVALUME ROUND 2 GALVALUME<br />

GEARLOCK 3 POLYOLEFIN SQUARE 3 GALVALUME<br />

ROUND 2 GALVALUME GEARLOCK 3 POLYOLEFIN<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

Installation Tool With Screw Gun (optional/required)<br />

REQUIRED<br />

Special Tool Needed (optional/required)<br />

Other DRILL BIT WITH ROTARY HAMMER HAMMER DRILL<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3,000 PSI AGED 28 DAYS) 1110 1031<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I CONCRETE ROOF<br />

CONSTRUCTION (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

550


<strong>Roof</strong> Fasteners: Concrete Decks<br />

ITW BUILDEX JOHNS MANVILLE INTERNATIONAL INC. NATIONAL NAIL CORPORATION<br />

#15 ROOFGRIP CD-10 ARDOX H.T. GALVANIZE CONCRETE<br />

U.S. U.S. CANADA<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

HARDENED CARBON STEEL HARDENED CARBON STEEL HARDENED STEEL<br />

CLIMASEAL CR-10 HOT-DIPPED GALVANIZED<br />

THREADED SPLIT SHANK SPIRAL FLUTED<br />

SELF-DRILLING 45 DEGREE DIAMOND STARTER DIAMOND<br />

THREADED SHANK EXPANSION FRICTION<br />

0.260 1-1/4 1/4 1 0.215 2 1 1 0.212 1-1/8 1/2 1<br />

0.260 2 1 1 0.215 2-1/2 1-1/2 1 0.212 1-1/2 3/4 1<br />

0.260 3 2 1 0.215 3 2 1 0212 2 1-1/4 1<br />

0.260 4 3 1 0.215 3-1/2 2-1/2 1 0.212 2-1/2 1-3/4 1<br />

0.260 5 4 1 0.215 4 3 1 0212 3 2-1/4 1<br />

0.260 6 5 1 0.215 4-1/2 3-1/2 1 0.212 3-1/2 2-3/4 1<br />

0.260 7 6 1 0.215 5 4 1 0212 4 3-1/4 1<br />

0.260 8 7 1 0.215 5-1/2 4-1/2 1 0.212 4-1/2 3-3/4 1<br />

0.260 10 9 1 0.215 6 5 1 0212 5 4-1/4 1<br />

0.260 12 11 1 0.215 7 6 1 0.212 5-1/2 4-3/4 1<br />

0.260 14 13 1 0.215 8 7 1 0212 6 5-1/4 1<br />

0.260 16 15 1 0.215 9 8 1 0.212 6-1/2 5-3/4 1<br />

0212 7 6-1/4 1<br />

0212 8 6-3/4 1<br />

0212 9 7-1/4 1<br />

0212 10 7-3/4 1<br />

0212 12 8-1/4 1<br />

#3 PHILLIPS PAN HEAD ROUND COMMON TYPE<br />

0.118 0.125 0.09375<br />

0.448 0.435 0.4375<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2 GALVALUME ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

SQUARE 3 GALVALUME<br />

REQUIRED<br />

HAMMER DRILL HAMMER DRILL ROTARY DRILL AND HAMMER<br />

1157 1164 600<br />

YES YES NO<br />

FM FM, UL, ICBO, METRO-DADE COUNTY --<br />

YES YES NO<br />

X<br />

551


<strong>Roof</strong> Fasteners: Concrete Decks<br />

1. COMPANY NAME OLYMPIC MANUFACTURING GROUP OLYMPIC MANUFACTURING GROUP<br />

2. PRODUCT NAME FLUTED CONCRETE NAIL OLYMPIC FASTENER HD #14 (C. STEEL)<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HARDENED CARBON STEEL HARDENED CARBON STEEL<br />

6. COATING TYPE CR-10 CR-10<br />

7. SHANK TYPE SPIRAL FLUTED THREADED<br />

8. POINT TYPE DIAMOND PINCH, SELF-DRILLING OR TAPEX<br />

9. METHOD OF ATTACHMENT FRICTION THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.215 1-1/8 1/8 1 0.190 1-1/4 1/4 1<br />

0.215 1-1/2 1/2 1 0.190 1-3/4 3/4 1<br />

0.215 2 1 1 0.190 2 1 1<br />

0.215 2-1/2 1-1/2 1 0.190 3 2 1<br />

0.215 3 2 1 0.190 4 3 1<br />

0.215 3-1/2 2-1/2 1 0.190 5 4 1<br />

0.215 4 3 1 0.190 6 5 1<br />

0.215 4-1/2 3-1/2 1 0.190 7 6 1<br />

0.215 5 4 1 0.190 8 7 1<br />

0.215 5-1/2 4-1/2 1 0.190 9 8 1<br />

0.215 6 5 1 0.190 10 9 1<br />

0.215 6-1/2 5-1/2 1 0.190 11 10 1<br />

0.215 7 6 1 0.190 12 11 1<br />

0.215 7-1/2 6-1/2 1 0.190 14 13 1<br />

0.215 8 7 1 0.190 16 15 1<br />

0.190 17 16 1<br />

0.201 18 17 1<br />

0.201 20 19 1<br />

0.201 21 20 1<br />

0.201 22 21 1<br />

0.201 24 23 1<br />

11. HEAD SHAPE ROUND ROUND TRUSS, #3 PHILLIPS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.125 0.110<br />

Diameter 0.425 0.435<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 2 STEEL ROUND 2 STEEL<br />

ROUND 2 PLASTIC ROUND 2 PLASTIC<br />

ROUND 2 STAINLESS STEEL ROUND 2 STAINLESS STEEL<br />

ROUND 3 STEEL ROUND 3 STEEL<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

ROUND 3 STAINLESS STEEL ROUND 3 STAINLESS STEEL<br />

ROUND 3-1/2 STEEL ROUND 3-1/2 STEEL<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

OPTIONAL<br />

Other HAMMER DRILL HAMMER DRILL (REQUIRED)<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3,000 PSI AGED 28 DAYS) 600 800<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I CONCRETE ROOF<br />

CONSTRUCTION (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, UL, ICBO, METRO-DADE COUNTY FM, UL, ICBO, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES X<br />

20. SEE APPENDIX IF CHECKED X<br />

NA = not applicable<br />

552


<strong>Roof</strong> Fasteners: Concrete Decks<br />

OLYMPIC MANUFACTURING GROUP POWERS FASTENERS POWERS FASTENERS<br />

OLYMPIC CD-10 POWERS RAWL 3/16" SPIKE POWERS RAWL 1/4" SPIKE<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

HARDENED CARBON STEEL HEAT TREADED CARBON STEEL HEAT TREADED CARBON STEEL<br />

CR-10 PERMA-SEAL FLUOROPOLYMER PERMA-SEAL FLUOROPOLYMER<br />

SPLIT BULB NA NA<br />

DIAMOND STARTER POINT NA NA<br />

COMPRESSION PRE-EXPANDED SHANK COMPRESSION PRE-EXPANDED SHANK COMPRESSION<br />

0.215 2 1 1 0.190 1 1/8 7/8 0.240 1 1/8 7/8<br />

0.215 2-1/2 1-1/2 1 0.190 1-1/4 3/8 7/8 0.240 1-1/4 3/8 7/8<br />

0.215 3 2 1 0.190 1-1/2 1/4 1-1/4 0.240 1-1/2 1/4 1-1/4<br />

0.215 3-1/2 2-1/2 1 0.190 2 3/4 1-1/4 0.240 2 3/4 1-1/4<br />

0.215 4 3 1 0.190 2-1/2 1-1/4 1-1/4 0.240 2-1/2 1-1/4 1-1/4<br />

0.215 4-1/2 3-1/2 1 0.190 3 1-3/4 1-1/4 0.240 3 1-3/4 1-1/4<br />

0.215 5 4 1 0.190 3-1/2 2-1/4 1-1/4 0.240 3-1/2 2-1/4 1-1/4<br />

0.215 5-1/2 4-1/2 1 0.190 4 2-3/4 1-1/4 0.240 4 2-3/4 1-1/4<br />

0.215 6 5 1 0.190 4-1/2 3-1/4 1-1/4 0.240 4-1/2 3-1/4 1-1/4<br />

0.215 7 6 1 0.190 5 3-3/4 1-1/4 0.240 5 3-3/4 1-1/4<br />

0.215 8 7 1 0.190 5-1/2 4-1/4 1-1/4 0.240 5-1/2 4-1/4 1-1/4<br />

0.215 9 8 1 0.190 6 4-3/4 1-1/4 0.240 6 4-3/4 1-1/4<br />

0.215 10 9 1 0.190 7 5-3/4 1-1/4 0.240 6-1/2 4-3/4 1-1/4<br />

0.215 12 11 1 0.190 8 6-3/4 1-1/4 0.240 7 5-3/4 1-1/4<br />

0.215 14 13 1 0.190 9 7-3/4 1-1/4 0.240 7-1/2 6-1/4 1-1/4<br />

0.190 10 8-3/4 1-1/4 0.240 8 6-3/4 1-1/4<br />

0.240 9 7-3/4 1-1/4<br />

0.240 10 8-3/4 1-1/4<br />

0.240 11 9-3/4 1-1/4<br />

0.240 12 10-3/4 1-1/4<br />

0.240 12 10-3/4 1-1/4<br />

0.240 13 11-3/4 1-1/4<br />

0.240 14 12-3/4 1-1/4<br />

ROUND MUSHROOM MUSHROOM<br />

0.100 0.110 0.110<br />

0.425 0.445 0.422<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2 STEEL ROUND BARBED 2 GALVALUME ROUND BARBED 2 GALVALUME<br />

ROUND 2 PLASTIC ROUND 3 GALVALUME ROUND 3 GALVALUME<br />

ROUND 2 STAINLESS STEEL ROUND 3 STAINLESS STEEL ROUND BARBED 3 STAINLESS STEEL<br />

ROUND 3 STEEL ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

ROUND 3 PLASTIC<br />

ROUND 3 STAINLESS STEEL<br />

HAMMER DRILL HAMMER DRILL (REQUIRED) HAMMER DRILL (REQUIRED)<br />

800 975 1100<br />

YES YES YES<br />

FM, UL, ICBO, METRO-DADE COUNTY FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

YES YES YES<br />

553


<strong>Roof</strong> Fasteners: Concrete Decks<br />

1. COMPANY NAME POWERS FASTENERS POWERS FASTENERS<br />

2. PRODUCT NAME POWERS RAWL #14 DECK SCREW POWERS RAWL #15 DECK SCREW<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CASE HARDENED CARBON STEEL CASE HARDENED CARBON STEEL<br />

6. COATING TYPE PERMA-SEAL FLUOROPOLYMER PERMA-SEAL FLUOROPOLYMER<br />

7. SHANK TYPE SPIRAL THREAD SPIRAL THREAD<br />

8. POINT TYPE DRILL TYPE RICOH "S" POINT<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.238 1-5/8 1/8 1-1/2 0.264 1-1/4 -- 1-1/2<br />

0.238 2-1/4 3/4 1-1/2 0.264 2 1/2 1-1/2<br />

0.238 2-7/8 1-3/8 1-1/2 0.264 3 1-1/2 1-1/2<br />

0.238 3-3/4 2-1/4 1-1/2 0.264 4 2-1/2 1-1/2<br />

0.238 4-1/2 3 1-1/2 0.264 5 3-1/2 1-1/2<br />

0.238 5 3-1/2 1-1/2 0.264 6 4-1/2 1-1/2<br />

0.238 6 4-1/2 1-1/2 0.264 7 5-1/2 1-1/2<br />

0.238 7 5-1/2 1-1/2 0.264 8 6-1/2 1-1/2<br />

0.238 8 6-1/2 1-1/2 0.264 9 7-1/2 1-1/2<br />

0.238 10 8-1/2 1-1/2 0.264 10 9-1/2 1-1/2<br />

0.238 12 10-1/2 1-1/2 0.264 12 10-1/2 1-1/2<br />

0.264 14 12-1/2 1-1/2<br />

0.264 16 14-1/2 1-1/2<br />

11. HEAD SHAPE PHILLIPS FLAT TRUSS HEAD #3 RECESS PHILLIPS TRUSS HEAD #3 RECESS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.118 0.130<br />

Diameter 0.448 0.448<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND BARBED 2 GALVALUME ROUND BARBED 2 GALVALUME<br />

ROUND 3 GALVALUME ROUND 3 GALVALUME<br />

ROUND 3 STAINLESS STEEL ROUND 3 STAINLESS STEEL<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required) STAND-UP TOOL (OPTIONAL) STAND-UP TOOL (OPTIONAL)<br />

Special Tool Needed (optional/required)<br />

Other HAMMER DRILL (REQUIRED) HAMMER DRILL (REQUIRED)<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3,000 PSI AGED 28 DAYS) 960 1015<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I CONCRETE ROOF<br />

CONSTRUCTION (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM FM<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

554


<strong>Roof</strong> Fasteners: Concrete Decks<br />

SFS STADLER INC. SFS STADLER INC. SFS STADLER INC.<br />

INSUL-FIXX $14-10 STADLER SPIKE STADLER SPIKE<br />

U.S.<br />

U.S<br />

X X X<br />

X<br />

X<br />

X X X<br />

HARDENED STEEL HARDENED STEEL HARDENED STEEL<br />

TUFF-TITE II PERMASEAL PERMASEAL<br />

SPIRAL THREAD -- --<br />

DRILL POINT NA NA<br />

THREADED COMPRESSION COMPRESSION<br />

0.190 1-1/4 1/4 1 0.187 1-1/2 1/4 1-1/4 0.240 1-1/2 1/4 1-1/4<br />

0.190 2 1 1 0.187 2 3/4 1-1/4 0.240 2 3/4 1-1/4<br />

0.190 3 2 1 0.187 2-1/2 1-1/4 1-1/4 0.240 2-1/2 1-1/4 1-1/4<br />

0.190 4 3 1 0.187 3 1-3/4 1-1/4 0.240 3 1-3/4 1-1/4<br />

0.190 5 4 1 0.187 3-1/2 2-1/4 1-1/4 0.240 3-1/2 2-1/4 1-1/4<br />

0.190 6 5 1 0.187 4 2-3/4 1-1/4 0.240 4 2-3/4 1-1/4<br />

0.190 7 6 1 0.187 4-1/2 3-1/4 1-1/4 0.240 4-1/2 3-1/4 1-1/4<br />

0.190 8 7 1 0.187 5 3-3/4 1-1/4 0.240 5 3-3/4 1-1/4<br />

0.190 9 8 1 0.187 5-1/2 4-1/4 1-1/4 0.240 5-1/2 4-1/4 1-1/4<br />

0.190 10 9 1 0.187 6 4-3/4 1-1/4 0.240 6 4-3/4 1-1/4<br />

0.190 12 11 1 0.187 6-1/2 5-1/4 1-1/4 0.240 6-1/2 5-1/4 1-1/4<br />

0.190 14 13 1 0.187 7 5-3/4 1-1/4 0.240 7 5-3/4 1-1/4<br />

0.190 16 15 1 0.187 7-1/2 6-1/4 1-1/4 0.240 8 6-3/4 1-1/4<br />

0.187 8 6-3/4 1-1/4 0.240 9 7-3/4 1-1/4<br />

0.187 9 7-3/4 1-1/4 0.240 10 8-3/4 1-1/4<br />

0.187 10 8-3/4 1-1/4 0.240 10 8-3/4 1-1/4<br />

0.240 12 10-3/4 1-1/4<br />

0.240 14 12-3/4 1-1/4<br />

0.240 14 12-3/4 1-1/4<br />

ROUND WITH #3 PHILLIPS TRUSS ROUND ROUND<br />

0.103 0.110 0.110<br />

0.425 0.422 0.422<br />

YES YES YES<br />

YES YES YES<br />

ROUND 3 GALVALUME ROUND 3 GALVALUME ROUND 3 GALVALUME<br />

ROUND 2 GALVALUME ROUND 2 GALVALUME ROUND 2 GALVALUME<br />

REQUIRED<br />

SDS SPIKE DRIVER (OPTIONAL)<br />

HAMMER (REQUIRED)<br />

SDS SPIKE DRIVER (OPTIONAL)<br />

HAMMER (REQUIRED)<br />

648 1100 1100<br />

YES YES YES<br />

FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

YES YES YES<br />

X<br />

555


<strong>Roof</strong> Fasteners: Concrete Decks<br />

1. COMPANY NAME SFS STADLER INC. SIMPLEX<br />

2. PRODUCT NAME EXTRA LOAD FASTENER HD ZNACHOR DRIVE NAIL EGS-PIN<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment<br />

X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE HARDENED STEEL ZINC (ZAMAK 7)<br />

6. COATING TYPE TUFF-TITE II ZINC<br />

7. SHANK TYPE THREADED ELECTRO GALVANIZED CARBON STEEL<br />

8. POINT TYPE DRILL POINT BLUNT<br />

9. METHOD OF ATTACHMENT THREADED SLEEVE EXPANSION<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.205 1-1/4 3/4 1 1/4 3/4 1/4 1/2<br />

0.205 2 1 1 3/16 7/8 3/8 1/2<br />

0.205 3 2 1 1/4 1 1/8 7/8<br />

0.205 4 3 1 1/4 1-1/4 3/8 7/8<br />

0.205 5 4 1 1/4 1-1/2 5/8 7/8<br />

0.205 6 5 1 1/4 2 1-1/8 7/8<br />

0.205 7 6 1<br />

0.205 8 7 1<br />

0.205 9 8 1<br />

0.205 10 9 1<br />

0.205 12 10 1<br />

0.205 12 11 1<br />

0.205 14 13 1<br />

0.205 16 15 1<br />

11. HEAD SHAPE ROUND WITH #3 PHILLIPS MUSHROOM<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.103 0.125<br />

Diameter 0.425 0.550<br />

13. PLATES<br />

Required (yes/no) YES NO<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 3 GALVALUME PARABOLIC 2 GALVALUME<br />

ROUND 2 GALVALUME PARABOLIC 3 GALVALUME<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

NA<br />

Installation Tool With Screw Gun (optional/required)<br />

NA<br />

Special Tool Needed (optional/required) REQUIRED TERMINATION BARS CAN BE USED (OPTIONAL)<br />

Other HAMMER DRILL OR IMPACT 1/4" DRILL BIT AND DRILL (REQUIRED)<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3,000 PSI AGED 28 DAYS) 1345 648, NA, 937, 1151, 1184, 1272<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I CONCRETE ROOF<br />

CONSTRUCTION (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, METRO-DADE COUNTY DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

556


<strong>Roof</strong> Fasteners: Concrete Decks<br />

SIMPLEX SIMPLEX TRU-FAST CORPORARTION<br />

ZNACHOR DRIVE NAIL SS-PIN MASONRY ROUND METAL CAP EHD (EXTRA HEAVY DUTY) #15<br />

U.S. U.S. U.S.<br />

X<br />

X<br />

X X X<br />

X X<br />

ZINC (ZAMAK 7) HARDENED CARBON STEEL CARBON STEEL C-1022<br />

ZINC NA TRU-KOTE (FLUOROPOLYMER PAINT)<br />

STAINLESS STEEL FLUTED THREADED<br />

BLUNT DIAMOND<br />

SLEEVE EXPANSION FLUTED FRICTION THREADED<br />

1/4 3/4 1/4 1/2 0.148 3/4 -- 3/4 0.204 1-1/4 3/4 1<br />

3/16 7/8 3/8 1/2 0.148 7/8 -- 7/8 0.204 2 1-1/2 1<br />

1/4 1 1/8 7/8 0.148 1 -- 3/4 0.204 3 2-1/2 1<br />

1/4 1-1/4 3/8 7/8 0.148 1-1/4 1/4 1 0.204 4 3-1/2 1<br />

1/4 1-1/2 5/8 7/8 0.148 1-1/2 1/2 1 0.204 5 4-1/2 1<br />

1/4 2 1-1/8 7/8 0.148 2 1 1 0.204 6 5-1/2 1<br />

0.148 2-1/2 1-1/2 1 0.204 7 6-1/2 1<br />

0.148 3 2 1 0.204 8 7-1/2 1<br />

0.148 3-1/2 2-1/2 1 0.204 9 8-1/2 1<br />

0.148 4 3 1 0.204 10 9-1/2 1<br />

0.204 11 10-1/2 1<br />

0.204 12 11-1/2 1<br />

0.204 14 13-1/2 1<br />

0.204 16 15-1/2 1<br />

0.204 18 17-1/2 1<br />

0.204 20 19-1/2 1<br />

MUSHROOM ROUND TRUSS #3 PHILLIPS<br />

0.125 0.037 0.105<br />

0.550 1.000 0.440<br />

NO NO YES<br />

YES YES YES<br />

PARABOLIC 2 GALVALUME PARABOLIC 2 GALVALUME ROUND 2 GALVALUME<br />

PARABOLIC 3 GALVALUME PARABOLIC 3 GALVALUME ROUND 2.4 GALVALUME<br />

ROUND 3 GALVALUME<br />

ROUND 3 PLASTIC<br />

NA NA REQUIRED<br />

NA NA OPTIONAL<br />

TERMINATION BARS CAN BE USED (OPTIONAL)<br />

NA<br />

1/4" DRILL BIT AND DRILL (REQUIRED) MAGNETIC POLE HAMMER OR REGULAR ROOFING HAMMER<br />

648, NA, 937, 1151, 1184, 1272 NA --<br />

YES NO YES<br />

DADE COUNTY NONE --<br />

YES YES YES<br />

X<br />

X<br />

557


<strong>Roof</strong> Fasteners: Concrete Decks<br />

1. COMPANY NAME TRU-FAST CORPORATION TRU-FAST CORPORATION<br />

2. PRODUCT NAME CF TAP GRIP HD (HEAVY DUTY) #14<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

5. MATERIAL TYPE CARBON STEEL C-1022 CARBON STEEL C-1022<br />

6. COATING TYPE TRU-KOTE (FLUOROPOLYMER PAINT) TRU-KOTE (FLUOROPOLYMER PAINT)<br />

7. SHANK TYPE THREADED THREADED<br />

8. POINT TYPE --<br />

9. METHOD OF ATTACHMENT THREADED THREADED<br />

10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.180 1-1/4 1/4 1 0.180 1-1/2 1/2 1<br />

0.180 1-3/4 3/4 1 0.180 2 1 1<br />

0.180 2-1/4 1-1/4 1 0.180 3 2 1<br />

0.180 2-3/4 1-3/4 1 0.180 4 3 1<br />

0.180 3-1/4 2-1/4 1 0.180 5 4 1<br />

0.180 3-3/4 2-3/4 1 0.180 6 5 1<br />

0.180 4-1/4 3-1/4 1 0.180 7 6 1<br />

0.180 5 4 1 0.180 8 7 1<br />

0.180 5-1/2 4-1/2 1 0.180 9 8 1<br />

0.180 6 5 1 0.180 10 9 1<br />

0.180 6-1/2 5-1/2 1 0.180 11 10 1<br />

0.180 7 6 1 0.180 12 11 1<br />

0.180 7-1/2 6-1/2 1<br />

0.180 8 7 1<br />

0.180 9 8 1<br />

0.180 10 9 1<br />

0.180 11 10 1<br />

0.180 12 11 1<br />

11. HEAD SHAPE MODIFIED PHILLIPS #3 TRUSS #3 PHILLIPS<br />

12. HEAD DIMENSIONS (inches)<br />

Thickness 0.118 0.105<br />

Diameter 0.445 0.440<br />

13. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

14. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 2 GALVALUME ROUND 2 GALVALUME<br />

ROUND 2.4 GALVALUME ROUND 2.4 GALVALUME<br />

ROUND 3 GALVALUME ROUND 3 GALVALUME<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

15. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

Installation Tool With Screw Gun (optional/required) REQUIRED REQUIRED<br />

Special Tool Needed (optional/required) OPTIONAL OPTIONAL<br />

Other<br />

16. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)<br />

3,000 PSI AGED 28 DAYS) 925 740<br />

17. MEETS THE FM APPROVAL REQUIREMENTS AS A<br />

COMPONENT OF A CLASS I CONCRETE ROOF<br />

CONSTRUCTION (yes/no) YES YES<br />

18. ACCEPTED BY THE FOLLOWING CODES FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

558


<strong>Roof</strong> Fasteners: Concrete Decks<br />

U.S. INTEC<br />

DRILL-TEC TAP GRIP<br />

U.S.<br />

X<br />

X<br />

CARBON STEEL<br />

FLUOROPOLYMER PAINT<br />

THREADED<br />

--<br />

MECHANICAL<br />

0.204 1-1/4 1/4 1<br />

0.204 2 1 1<br />

0.204 3 2 1<br />

0.204 4 3 1<br />

0.204 5 4 1<br />

0.204 6 5 1<br />

0.204 7 6 1<br />

0.204 8 7 1<br />

0.204 9 8 1<br />

0.204 10 9 1<br />

0.204 12 11 1<br />

0.204 14 13 1<br />

0.204 16 15 1<br />

0.204 18 17 1<br />

0.204 20 19 1<br />

0.204 22 21 1<br />

0.204 24 23 1<br />

0.204 26 25 1<br />

TRUSS, #3 PHILLIPS<br />

--<br />

--<br />

YES<br />

YES<br />

ROUND 2.7 GALVALUME<br />

ROUND 3 PLASTIC<br />

REQUIRED<br />

OPTIONAL<br />

925<br />

YES<br />

FM, METRO-DADE COUNTY<br />

YES<br />

559


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

1. COMPANY NAME CARLISLE SYNTEC INCORPORATED CARLISLE SYNTEC INCORPORATED<br />

2. PRODUCT NAME HP SPEED-LOCK TOGGLE BOLT HP TOGGLE BOLT<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. DECK TYPE:<br />

Lightweight Concrete X X<br />

Gypsum X X<br />

Cementitious Wood Fiber X X<br />

5. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

Single-Ply Membranes X X<br />

6. MATERIAL TYPE CARBON STEEL CARBON STEEL<br />

7. COATING TYPE ZINC-BASED PRIMER, FLUOROPOLYMER COATING ZINC RICH COATING, LOCKING ADHESIVE<br />

8. SHANK TYPE THREADED THREADED<br />

9. POINT TYPE NA NA<br />

10. METHOD OF ATTACHMENT TOGGLE BOLT PLUS WING THROUGH PRE-DRILLED HOLE TOGGLE BOLT PLUS WING THROUGH PRE-DRILLED HOLE<br />

11. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.215 4 2-1/2 1-1/2 0.215 4 2-1/2 1-1/2<br />

0.215 6 4-1/2 1-1/2 0.215 6 4-1/2 1-1/2<br />

0.215 7 5-1/2 1-1/2 0.215 7 5-1/2 1-1/2<br />

0.215 8 6-1/2 1-1/2 0.215 8 6-1/2 1-1/2<br />

0.215 9 7-1/2 1-1/2 0.215 10 9-1/2 1-1/2<br />

0.215 10 9-1/2 1-1/2 0.215 12 10-1/2 1-1/2<br />

0.215 12 10-1/2 1-1/2 0.215 14 12-1/2 1-1/2<br />

0.215 14 12-1/2 1-1/2 0.215 16 14-1/2 1-1/2<br />

0.215 16 14-1/2 1-1/2<br />

12. HEAD SHAPE ROUND TRUSS WITH #3 PHILLIPS ROUND TRUSS WITH #3 PIHLLIPS<br />

13. HEAD DIMENSIONS (inches)<br />

Thickness 0.110 0.110<br />

Diameter 0.435 0.435<br />

14. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

15. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

SQUARE W/ROUNDED<br />

SQUARE W/ROUNDED<br />

CORNERS 2-7/8 GALVALUME CORNERS 2-7/8 GALVALUME<br />

ROUND 2 GALVALUME ROUND 2 GALVALUME<br />

16. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

Other<br />

17. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

Lightweight Concrete --- --<br />

Gypsum -- --<br />

Cementitious Wood Fiber -- --<br />

18. ACCEPTED BY THE FOLLOWING CODES<br />

Lightweight Concrete<br />

Gypsum<br />

Cementitious Wood Fiber<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

560


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

CARLISLE SYNTEC INCORPORATED CARLISLE SYNTEC INCORPORATED CARLISLE SYNTEC NCORPORATED<br />

HP LIGHTWEIGHT FASTENER HP NTB WITH & WITHOUT WIRES HP LITE-DECK<br />

U.S. U.S. U.S.<br />

X X<br />

X X X<br />

X X X<br />

X X X<br />

X X X<br />

NYLON NYLON HARDENED CARBON STEEL<br />

NA NA EPOXY ELECTRODEPOSITION<br />

SPIRAL THREAD SPIRAL THREAD THREADED<br />

GIMLET GIMLET PINCH<br />

THREADED, SUBSTRATE COMPACTION THREADED WITH & WITHOUT WIRES THREADED<br />

0.430 2 1/2 1-1/2 0.4375 2-1/2 1 1-1/2 0.310 3 1 2<br />

0.430 2-1/2 1 1-1/2 0.4375 3 1-1/2 1-1/2 0.310 4 2 2<br />

0.430 3 1-1/2 1-1/2 0.4375 3-1/2 2 1-1/2 0.310 5 3 2<br />

0.430 3-1/2 2 1-1/2 0.4375 4 2-1/2 1-1/2 0.310 6 4 2<br />

0.430 4 2-1/2 1-1/2 0.4375 4-1/2 3 1-1/2 0.310 7 5 2<br />

0.430 4-1/2 3 1-1/2 0.4375 5 3-1/2 1-1/2 0.310 8 6 2<br />

0.430 5 3-1/2 1-1/2 0.4375 5-1/2 4 1-1/2 0.310 9 7 2<br />

0.430 5-1/2 4 1-1/2 0.4375 6 4-1/2 1-1/2 0.310 10 8 2<br />

0.430 6 4-1/2 1-1/2 0.4375 6-1/2 5 1-1/2 0.310 12 10 2<br />

0.430 6-1/2 5 1-1/2 0.4375 7 5-1/2 1-1/2<br />

0.430 7 5-1/2 1-1/2 0.4375 7-1/2 6 1-1/2<br />

0.430 7-1/2 6 1-1/2 0.4375 8 6-1/2 1-1/2<br />

0.430 8 6-1/2 1-1/2 0.4375 8-1/2 7 1-1/2<br />

0.430 8-1/2 7 1-1/2 0.4375 9 7-1/2 1-1/2<br />

0.430 9 7-1/2 1-1/2 0.4375 9-1/2 8 1-1/2<br />

0.430 9-1/2 8 1-1/2 0.4375 10 8-1/2 1-1/2<br />

0.430 10 8-1/2 1-1/2<br />

ROUND, 1/4-IN. RECESS ROUND, DOUBLE HEX ROUND #3 PHILLIPS<br />

0.120 0.100 --<br />

1.00 1.00 0.558<br />

YES YES YES<br />

YES YES YES<br />

ROUND BARBED 2 GALVALUME ROUND BARBED 2 CARBON STEEL ROUND 3 CARBON STEEL<br />

ROUND BARBED 3 GALVALUME ROUND BARBED 3 CARBON STEEL<br />

OPTIONAL<br />

REQUIRED<br />

IMPACT WRENCH, ELECTRIC DRILL (OPTIONAL)<br />

ELIMINATOR TOOL (OPTIONAL)<br />

IMPACT WRENCH/ELIMINATOR (OPTIONAL)<br />

-- -- --<br />

-- -- --<br />

-- -- --<br />

FM<br />

FM FM FM<br />

FM FM FM<br />

YES YES YES<br />

561


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

1. COMPANY NAME CELOTEX CORP. CONSTRUCTION FASTENERS INC.<br />

2. PRODUCT NAME ANCHORBOND AUGUR FASTENER DEKLITE<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. DECK TYPE:<br />

Lightweight Concrete X X<br />

Gypsum X X<br />

Cementitious Wood Fiber X X<br />

5. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

6. MATERIAL TYPE NYLON NYLON<br />

7. COATING TYPE NA NA<br />

8. SHANK TYPE SPIRAL THREAD SPIRAL THREAD<br />

9. POINT TYPE GIMLET GIMLET<br />

10. METHOD OF ATTACHMENT THREADED, SUBSTRATE COMPACTION THREADED, SUBSTRATE COMPACTION<br />

11. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.430 2 1/2 1-1/2 0.687 2 1/2 1-1/2<br />

0.430 2-1/2 1 1-1/2 0.687 2-1/2 1 1-1/2<br />

0.430 3 1-1/2 1-1/2 0.687 3 1-1/2 1-1/2<br />

0.430 3-1/2 2 1-1/2 0.687 3-1/2 2 1-1/2<br />

0.430 4 2-1/2 1-1/2 0.687 4 2-1/2 1-1/2<br />

0.430 4-1/2 3 1-1/2 0.687 4-1/2 3 1-1/2<br />

0.430 5 3-1/2 1-1/2 0.687 5 3-1/2 1-1/2<br />

0.430 5-1/2 4 1-1/2 0.687 5-1/2 4 1-1/2<br />

0.430 6 4-1/2 1-1/2 0.687 6 4-1/2 1-1/2<br />

0.430 6-1/2 5 1-1/2 0.687 6-1/2 5 1-1/2<br />

0.430 7 5-1/2 1-1/2 0.687 7 5-1/2 1-1/2<br />

0.430 7-1/2 6 1-1/2 0.687 7-1/2 6 1-1/2<br />

0.430 8 6-1/2 1-1/2 0.687 8 6-1/2 1-1/2<br />

0.430 8-1/2 7 1-1/2 0.687 8-1/2 7 1-1/2<br />

0.430 9 7-1/2 1-1/2 0.687 9 7-1/2 1-1/2<br />

0.430 9-1/2 8 1-1/2 0.687 9-1/2 8 1-1/2<br />

0.430 10 8-1/2 1-1/2 0.687 10 8-1/2 1-1/2<br />

12. HEAD SHAPE ROUND, 1/4-IN. RECESS ROUND, 1/4-IN RECESS<br />

13. HEAD DIMENSIONS (inches)<br />

Thickness 0.120 0.120<br />

Diameter 1.00 1.00<br />

14. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

15. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND BARBED 2 GALVALUME ROUND BARBED 2 GALVALUME<br />

HEX BARBED 2-7/8 GALVALUME ROUND BARBED 3 GALVALUME<br />

16. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

Other IMPACT WRENCH, ELECTRIC DRILL (OPTIONAL) IMPACT WRENCH, ELECTRIC DRILL (OPTIONAL)<br />

17. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

Lightweight Concrete 450 365<br />

Gypsum 450 540<br />

Cementitious Wood Fiber 450 440<br />

18. ACCEPTED BY THE FOLLOWING CODES<br />

Lightweight Concrete<br />

FM, METRO-DADE COUNTY<br />

Gypsum<br />

FM, METRO-DADE COUNTY<br />

Cementitious Wood Fiber<br />

FM, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

562


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

DURO-LAST, INC. DURO-LAST, INC. ES PRODUCTS INC.<br />

N.T.B. MAGNUM WITH & WITHOUT WIRES DURO-LAST AUGER FASTENER HARDENED DO-ALL LOC-NAIL<br />

U.S. U.S. U.S.<br />

X<br />

X<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

NYLON DUPONT ZYTEL NYLON HARDENED COLD-ROLLED STEEL<br />

NA NA ZINC PLATE<br />

SPIRAL THRAED HIGH THREAD W/TAPPERED ROOT SPLIT, SERRATED<br />

NA SHARP TWO SHARP PONTS<br />

THREADED, SPIN WELD WITH & WITHOUT WIRES THREADED SPREAD OF SERRATED SHANKS<br />

0.4375 2-1/2 1 1-1/2 0.675 2 1/2 1-1/2 0.240 1-3/8 1/4 1-1/8<br />

0.4375 3 1-1/2 1-1/2 0.675 2-1/2 1 1-1/2<br />

0.4375 3-1/2 2 1-1/2 0.675 3 1-1/2 1-1/2<br />

0.4375 4 2-1/2 1-1/2 0.675 3-1/2 2 1-1/2<br />

0.4375 4-1/2 3 1-1/2 0.675 4 2-1/2 1-1/2<br />

0.4375 5 3-1/2 1-1/2 0.675 4-1/2 3 1-1/2<br />

0.4375 5-1/2 4 1-1/2 0.675 5 3-1/2 1-1/2<br />

0.4375 6 4-1/2 1-1/2 0.675 5-1/2 4 1-1/2<br />

0.4375 6-1/2 5 1-1/2 0.675 6 4-1/2 1-1/2<br />

0.4375 7 5-1/2 1-1/2 0.675 6-1/2 5 1-1/2<br />

0.4375 7-1/2 6 1-1/2 0.675 7 5-1/2 1-1/2<br />

0.4375 8 6-1/2 1-1/2 0.675 7-1/2 6 1-1/2<br />

0.4375 8-1/2 7 1-1/2 0.675 8 6-1/2 1-1/2<br />

0.4375 9 7-1/2 1-1/2 0.675 8-1/2 7 1-1/2<br />

0.4375 9-1/2 8 1-1/2 0.675 9 7-1/2 1-1/2<br />

0.4375 10 8-1/2 1-1/2 0.675 9-1/2 8 1-1/2<br />

0.675 10 8-1/2 1-1/2<br />

0.675 11 9-1/2 1-1/2<br />

0.675 12 10-1/2 1-1/2<br />

0.675 13 11-1/2 1-1/2<br />

0.675 14 12-1/2 1-1/2<br />

DOUBLE HEX 1/4" SQUARE DRIVE RECESS SQUARE WITH ROUNDED CORNERS<br />

0.100 0.134 0.050<br />

1.00 1.000 0.375<br />

YES YES YES<br />

YES YES YES<br />

ROUND W/SPIKES 3 CARBON STEEL ROUND BARBED 2 GALVALUME ROUND 1-3/8 PRE-TINNED STEEL<br />

ROUND BARBED 3 GALVALUME<br />

SCREW GUN<br />

SCREW GUN<br />

HAMMER<br />

--<br />

60<br />

--<br />

FM, METRO-DADE COUNTY<br />

FM<br />

FM, METRO-DADE COUNTY FM UL<br />

FM, METRO-DADE COUNTY<br />

FM<br />

YES YES YES<br />

563


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

1. COMPANY NAME ES PRODUCTS INC. ES PRODUCTS INC.<br />

2. PRODUCT NAME INSULDECK LOC-NAIL TWIN LOCK-NAIL<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. DECK TYPE:<br />

Lightweight Concrete<br />

Gypsum<br />

X<br />

Cementitious Wood Fiber X X<br />

5. USED WITH:<br />

Insulation Attachment<br />

X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes<br />

6. MATERIAL TYPE COLD-ROLLED STEEL COLD-R0LLED STEEL<br />

7. COATING TYPE GALVALUME (AZ-55) GALVALUME (AZ-55)<br />

8. SHANK TYPE DOUBLE THICKNESS HALF-ROUND TUBE<br />

9. POINT TYPE FINE, SHARP WEDGE<br />

10. METHOD OF ATTACHMENT AUTOMATIC KNEE-BEND GRIPPING DIVERGING WIRE LEGS<br />

11. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.230 1-7/8 1/4 1-1/8 NA 1.8 NA 1<br />

12. HEAD SHAPE ROUND, CUPPED ROUND<br />

13. HEAD DIMENSIONS (inches)<br />

Thickness 0.045 --<br />

Diameter 0.500 2.7<br />

14. PLATES<br />

Required (yes/no)<br />

YES<br />

Available From Manufacturer (yes/no)<br />

YES<br />

15. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 2.7 GALVALUME ROUND 2.7 GALVALUME<br />

16. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

INSULDECK DRIVER<br />

Other HAMMER TWIN LOC DRIVER<br />

17. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

Lightweight Concrete 60/100 --<br />

Gypsum -- 300<br />

Cementitious Wood Fiber 79 200<br />

18. ACCEPTED BY THE FOLLOWING CODES<br />

Lightweight Concrete<br />

Gypsum<br />

Cementitious Wood Fiber<br />

FM, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X<br />

NA = not applicable<br />

564


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

ES PRODUCTS INC. ES PRODUCTS INC. ES PRODUCTS INC.<br />

FM-75 BASE PLY FASTENER NAIL-TITE TYPE A NAIL-TITE TYPE R<br />

U.S. U.S. U.S.<br />

X<br />

X<br />

X<br />

X X X<br />

STEEL CARBON STEEL CARBON STEEL<br />

HOT-DIPPED G-90 GALVANIZED & URETHANE ZINC PLATED ZINC PLATED<br />

TWO-PIECE RECTANGULAR TAPERED CONE TAPERED COE<br />

NA ROUND ROUND<br />

SHANK EXPANSION CONICAL EXTENDING LEGS CONICAL EXTENDING LEGS<br />

NA 1-1/5 NA NA NA 1-1/2 1/16 1-7/16 NA 1 1/16 15/16<br />

ROUND ROUND ROUND<br />

-- 0.105 0.015<br />

2.70 1.7 1.7<br />

NO NO NO<br />

NA<br />

NA<br />

NA NA NA NA NA NA NA NA NA<br />

MAGNETIC DRIVER (REQUIRED) MAGNETIC DRIVER (REQUIRED) MAGNETIC DRIVER (REQUIRED)<br />

90 MIN NA NA<br />

NA 159 159<br />

NA NA NA<br />

FM, METRO-DADE COUNTY<br />

NA UL, FM, METRO-DADE COUNTY UL, FM, METRO-DADE COUNTY<br />

NA YES YES<br />

YES<br />

565


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

1. COMPANY NAME ES PRODUCTS INC. ES PRODUCTS INC.<br />

2. PRODUCT NAME ES-90 BASE PLY FASTENER ES-60 BASE PLY FASTENER<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. DECK TYPE:<br />

Lightweight Concrete X X<br />

Gypsum<br />

Cementitious Wood Fiber<br />

5. USED WITH:<br />

Insulation Attachment<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

6. MATERIAL TYPE STEEL STEEL<br />

7. COATING TYPE HOT DIPPED G-90 GALVANIZED HOT DIPPED G-90 GALVANIZED<br />

8. SHANK TYPE TWO-PIECE RECTANGULAR TWO-PIECE RECTANGULAR<br />

9. POINT TYPE NA NA<br />

10. METHOD OF ATTACHMENT SHANK EXPANSION SHANK EXPANSION<br />

11. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

NA 1-7/10 NA NA NA 1-7/10 NA NA<br />

12. HEAD SHAPE ROUND ROUND<br />

13. HEAD DIMENSIONS (inches)<br />

Thickness -- --<br />

Diameter 2.75 1.20<br />

14. PLATES<br />

Required (yes/no) NO NO<br />

Available From Manufacturer (yes/no) NO NO<br />

15. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

NA NA NA ROUND 2-3/4 GAVALUME<br />

16. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

Other MAGNETIC DRIVER (REQUIRED) MAGNETIC DRIVER (REQUIRED)<br />

17. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

Lightweight Concrete 90 MIN. 90 MIN.<br />

Gypsum NA NA<br />

Cementitious Wood Fiber NA NA<br />

18. ACCEPTED BY THE FOLLOWING CODES<br />

Lightweight Concrete -- --<br />

Gypsum NA NA<br />

Cementitious Wood Fiber NA NA<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

566


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

ES PRODUCTS INC. ES PRODUCTS INC. ES PRODUCTS INC.<br />

ES-45 BASE PLY FASTENER FM-90 BASE PLY FASTENER FM-60 BASE PLY FASTENER<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X<br />

X<br />

STEEL STEEL STEEL<br />

HOT DIPPED G-90 GALVANIZED HOT DIPPED G-90 GALVANIZED & URETHANE COATING HOT DIPPED G-90 GALVANIZED & URETHANE COATING<br />

TWO-PIECE RECTANGULAR TWO-PIECE RECTANGULAR TWO-PIECE RECTANGULAR<br />

NA NA NA<br />

SHANK EXPANSION SHANK EXPANSION SHANK EXPANSION<br />

NA 1-1/15 NA NA NA 1-7/10 NA NA NA 1-7/10 NA NA<br />

ROUND ROUND ROUND<br />

-- -- --<br />

1.20 2.75 1.20<br />

NO NO NO<br />

NO YES YES<br />

ROUND 2-3/4 GALVANIZED STEEL ROUND 2-3/4 GALVALUME<br />

MAGNETIC DRIVER (REQUIRED) MAGNETIC DRIVER (REQUIRED) MAGNETIC DRIVER (REQUIRED)<br />

90 MIN. 90 MIN. 90 MIN.<br />

NA NA NA<br />

NA NA NA<br />

-- FM, UL, METRO-DADE COUNTY FM, UL, METRO-DADE COUNTY<br />

NA FM, UL, METRO-DADE COUNTY FM, UL, METRO-DADE COUNTY<br />

NA NA NA<br />

YES YES YES<br />

567


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

1. COMPANY NAME ES PRODUCTS INC. FIRESTONE BUILDING PRODUCTS<br />

2. PRODUCT NAME FM-45 BASE PLY FASTENER FIRESTONE POLYMER FASTENERS<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. DECK TYPE:<br />

Lightweight Concrete<br />

X<br />

Gypsum<br />

X<br />

Cementitious Wood Fiber<br />

X<br />

5. USED WITH:<br />

Insulation Attachment<br />

X<br />

Built-Up Membranes<br />

X<br />

Single-Ply Membranes X X<br />

6. MATERIAL TYPE STEEL GLASS-REINFORCED NYLON<br />

7. COATING TYPE HOT DIPPED G-90 GALVANIZED & URETHANE COATING NA<br />

8. SHANK TYPE TWO-PIECE RECTANGULAR TAPERED ROOT, SPIRAL THREAD<br />

9. POINT TYPE NA GIMLET<br />

10. METHOD OF ATTACHMENT SHANK EXPANSION THREADED<br />

11. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

NA 1-1/15 NA NA 0.675 2 1/2 1-1/2<br />

0.675 2-1/2 1 1-1/2<br />

0.675 2-3/4 1-1/4 1-1/2<br />

0.675 3 1-1/2 1-1/2<br />

0.675 3-1/2 2 1-1/2<br />

0.675 4 2-1/2 1-1/2<br />

0.675 4-1/2 3 1-1/2<br />

0.675 5 3-1/2 1-1/2<br />

0.675 5-1/2 4 1-1/2<br />

0.675 6 4-1/2 1-1/2<br />

0.675 6-1/2 5 1-1/2<br />

0.675 7 5-1/2 1-1/2<br />

0.675 7-1/2 6 1-1/2<br />

0.675 8 6-1/2 1-1/2<br />

0.675 8-1/2 7 1-1/2<br />

0.675 9 7-1/2 1-1/2<br />

0.675 9-1/2 8 1-1/2<br />

0.675 10 8-1/2 1-1/2<br />

0.675 11 9-1/2 1-1/2<br />

0.675 12 10-1/2 1-1/2<br />

0.675 13 11-1/2 1-1/2<br />

0.675 14 12-1/2 1-1/2<br />

12. HEAD SHAPE ROUND ROUND, INTERNAL 1/4 IN. SQUARE DRIVE<br />

13. HEAD DIMENSIONS (inches)<br />

Thickness -- 0.140<br />

Diameter 1.20 1.00<br />

14. PLATES<br />

Required (yes/no) NO YES<br />

Available From Manufacturer (yes/no) YES YES<br />

15. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 2-3/4 GALVALUME ROUND INSULATION 3 GALVALUME<br />

ROUND (IN-SEAM) 2 GALVALUME<br />

16. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

Other MAGNETIC DRIVER (REQUIRED) IMPACT WRENCH, ELECTRIC DRILL (OPTIONAL)<br />

17. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

Lightweight Concrete 90 MIN. NA<br />

Gypsum NA 600<br />

Cementitious Wood Fiber NA 450<br />

18. ACCEPTED BY THE FOLLOWING CODES<br />

Lightweight Concrete FM, UL, METRO-DADE COUNTY NA<br />

Gypsum NA FM<br />

Cementitious Wood Fiber NA FM<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

568


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

GAF MATERIALS CORP. GAF MATERIALS CORP. GAF MATERIALS CORP.<br />

TOGGLE BOLT (STAINLESS STEEL) TOGGLE BOLT (CARBON STEEL) IRON-LOK TOGGLE BOLT<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X X X<br />

X X X<br />

X X X<br />

X<br />

X<br />

STAINLESS STEEL CARBON STEEL CARBON STEEL<br />

NA CR-10 FLUOROCARBON ENDURION WITH IRON-LOK ADHESIVE<br />

THREADED THREADED THREADED<br />

NA NA NA<br />

TOGGLE BOLT PLUS WING THRU PREDRILLED HOLE TOGGLE BOLT PLUS WING THRU PREDRILLED HOLE TOGGLE BOLT PLUS WING THRU PREDRILLED HOLE<br />

0.215 4 2-1/2 1-1/2 0.215 4 2-1/2 1-1/2 0.215 4 2-1/2 1-1/2<br />

0.215 6 4-1/2 1-1/2 0.215 6 4-1/2 1-1/2 0.215 6 4-1/2 1-1/2<br />

0.215 7 5-1/2 1-1/2 0.215 7 5-1/2 1-1/2 0.215 7 5-1/2 1-1/2<br />

0.215 8 6-1/2 1-1/2 0.215 8 6-1/2 1-1/2 0.215 8 6-1/2 1-1/2<br />

0.215 10 8-1/2 1-1/2 0.215 10 8-1/2 1-1/2 0.215 10 8-1/2 1-1/2<br />

0.215 12 10-1/2 1-1/2 0.215 12 10-1/2 1-1/2 0.215 12 10-1/2 1-1/2<br />

0.215 14 12-1/2 1-1/2 0.215 14 12-1/2 1-1/2 0.215 14 12-1/2 1-1/2<br />

0.215 16 14-1/2 1-1/2 0.215 16 14-1/2 1-1/2 0.215 16 14-1/2 1-1/2<br />

0.215 18 16-1/2 1-1/2 0.215 18 16-1/2 1-1/2 0.215 18 16-1/2 1-1/2<br />

0.215 20 18-1/2 1-1/2 0.215 20 18-1/2 1-1/2 0.215 20 18-1/2 1-1/2<br />

0.215 22 20-1/2 1-1/2 0.215 22 20-1/2 1-1/2 0.215 22 20-1/2 1-1/2<br />

0.215 24 22-1/2 1-1/2 0.215 24 22-1/2 1-1/2 0.215 24 22-1/2 1-1/2<br />

ROUND TRUSS WITH #3 PHILLIPS ROUND TRUSS WITH #3 PHILLIPS ROUND TRUSS WITH #3 PHILLIPS<br />

0.110 0.110 0.110<br />

0.435 0.435 0.435<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2 STAINLESS STEEL ROUND 2 STAINLESS STEEL ROUND 2 STAINLESS STEEL<br />

ROUND 2 STEEL ROUND 2 STEEL ROUND 2 STEEL<br />

ROUND 2 PLASTIC ROUND 2 PLASTIC ROUND 2 PLASTIC<br />

ROUND 3 STAINLESS STEEL ROUND 3 STAINLESS STEEL ROUND 3 STAINLESS STEEL<br />

ROUND 3 STEEL ROUND 3 STEEL ROUND 3 STEEL<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

REQUIRED REQUIRED REQUIRED<br />

600 600 600<br />

600 600 600<br />

600 600 600<br />

FM, METRO-DADE COUNTY<br />

FM, METRO-DADE COUNTY<br />

FM, METRO-DADE COUNTY<br />

FM, METRO-DADE COUNTY<br />

YES YES YES<br />

X X X<br />

569


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

1. COMPANY NAME GAF MATERIALS CORP. GAF MATERIALS CORP.<br />

2. PRODUCT NAME GAFTITE LITE-DECK GAFTITE BASE SHEET FASTENER<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. DECK TYPE:<br />

Lightweight Concrete<br />

X<br />

Gypsum<br />

X<br />

Cementitious Wood Fiber<br />

X<br />

5. USED WITH:<br />

Insulation Attachment<br />

X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

6. MATERIAL TYPE HARDENED CARBON STEEL STEEL<br />

7. COATING TYPE CR-10 FLUOROCARBON G-90 HOT DIPPED GALVANIZED OR CR-10 FLUOROCARBON<br />

8. SHANK TYPE THREADED SPLIT BODY<br />

9. POINT TYPE PINCH NA<br />

10. METHOD OF ATTACHMENT THREADED SHANK EXPANSION<br />

11. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.310 3 1 2 NA 1.81 NA NA<br />

0.310 4 2 2 NA 1.20<br />

0.310 5 3 2<br />

0.310 6 4 2<br />

0.310 8 6 2<br />

0.310 9 7 2<br />

0.310 10 8 2<br />

0.310 12 10 2<br />

12. HEAD SHAPE ROUND #3 PHILLIPS RECTANGULAR WITH ROUNDED CORNERS<br />

13. HEAD DIMENSIONS (inches)<br />

Thickness -- --<br />

Diameter 0.558 1 X 1.3<br />

14. PLATES<br />

Required (yes/no) YES NO<br />

Available From Manufacturer (yes/no) YES YES<br />

15. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 3 STEEL ROUND 2-3/4 G-90 GALVANIZED &<br />

GALVALUME<br />

16. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

Other<br />

MALLET (REQUIRED)<br />

17. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

Lightweight Concrete NA 40 MIN.<br />

Gypsum 450 40 MIN.<br />

Cementitious Wood Fiber 450 NA<br />

18. ACCEPTED BY THE FOLLOWING CODES<br />

Lightweight Concrete<br />

FM, UL, METRO-DADE COUNTY<br />

Gypsum<br />

NA<br />

Cementitious Wood Fiber<br />

NA<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES NO<br />

20. SEE APPENDIX IF CHECKED X<br />

NA = not applicable<br />

570


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

GAF MATERIALS CORP. ITW BUILDEX ITW BUILDEX<br />

TOGGLE-LESS MAGNUM/EVERGUARD POLYMER POLYMER GYPTEC LITE WEIGHT CONCRETE FASTENER<br />

U.S. U.S. U.S.<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X<br />

X X X<br />

NYLON GLASS-FILLED NYLON G-90 STEEL<br />

NA NA GRAY POLYMER<br />

SPIRAL THREAD THREADED AUGER TWO-PIECE RECTANGULAR<br />

NA TAPERED NA<br />

THREADED, SPIN WELD WITH & WIHTOUT WIRES THREADED SHANK EXPANSION<br />

0.4375 2-1/2 1 1-1/2 0.430 2-3/4 1 -1/4 1-1/2 NA 1.7 NA NA<br />

0.4375 3 1-1/2 1-1/2 0.430 3 1-1/2 1-1/2<br />

0.4375 3-1/2 2 1-1/2 0.430 3-1/2 2 1-1/2<br />

0.4375 4 2-1/2 1-1/2 0.430 4 2-1/2 1-1/2<br />

0.4375 4-1/2 3 1-1/2 0.430 4-1/2 3 1-1/2<br />

0.4375 5 3-1/2 1-1/2 0.430 5 3-1/2 1-1/2<br />

0.4375 5-1/2 4 1-1/2 0.430 5-1/2 4 1-1/2<br />

0.4375 6 4-1/2 1-1/2 0.430 6 4-1/2 1-1/2<br />

0.4375 6-1/2 5 1-1/2 0.430 6-1/2 5 1-1/2<br />

0.4375 7 5-1/2 1-1/2 0.430 7 5-1/2 1-1/2<br />

0.4375 7-1/2 6 1-1/2 0.430 7-1/2 6 1-1/2<br />

0.4375 8 6-1/2 1-1/2 0.430 8 6-1/2 1-1/2<br />

0.4375 8-1/2 7 1-1/2<br />

0.4375 9 7-1/2 1-1/2<br />

0.4375 9-1/2 8 1-1/2<br />

0.4375 10 8-1/2 1-1/2<br />

DOUBLE HEX ROUND, 1/4-IN. SQUARE RECESS ROUND<br />

0.100 0.130 --<br />

1.0 1.00 1.1<br />

YES YES NO<br />

YES YES YES<br />

ROUND W/SPIKES 2 NYLON SQUARE 3 X 3 GALVALUME ROUND 2.7 GALVALUME<br />

ROUND W/SPIKES 2 CARBON STEEL ROUND 2 GALVALUME<br />

ROUND W/SPIKES 3 CARBON STEEL<br />

OPTIONAL<br />

REQUIRED<br />

AIR WRENCH OR HANDSET TOLL (OPTIONAL)<br />

ELECTRIC IMPACT WRENCH/ELIMINATOR (OPTIONAL) 7/16-IN. DRILL BIT (REQUIRED FOR GYPSUM) BX LITE DRIVE<br />

375 NA 140<br />

450 528 --<br />

450 422 --<br />

FM NA FM, METRO-DADE COUNTY<br />

FM<br />

FM, METRO-DADE COUNTY<br />

FM<br />

FM, METRO-DADE COUNTY<br />

YES YES YES<br />

X<br />

X<br />

571


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

1. COMPANY NAME ITW BUILDEX JOHNS MANVILLE INTERNATIONAL INC.<br />

2. PRODUCT NAME 1.2 LITE WEIGHT CONCRETE FASTENER NTB<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. DECK TYPE:<br />

Lightweight Concrete<br />

X<br />

Gypsum X X<br />

Cementitious Wood Fiber<br />

X<br />

5. USED WITH:<br />

Insulation Attachment<br />

X<br />

Built-Up Membranes<br />

X<br />

Single-Ply Membranes<br />

X<br />

6. MATERIAL TYPE G-90 STEEL NYLON<br />

7. COATING TYPE BLACK POLYMER NA<br />

8. SHANK TYPE TWO-PIECE RECTANGULAR SPIRAL THREAD<br />

9. POINT TYPE NA NA<br />

10. METHOD OF ATTACHMENT SHANK EXPANSION THREADED, SPIN WELD WITH & WITHOUT WIRES<br />

11. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

NA 1.2 NA NA 0.4375 2-1/2 1 1-1/2<br />

0.4375 3 1-1/2 1-1/2<br />

0.4375 3-1/2 2 1-1/2<br />

0.4375 4 2-1/2 1-1/2<br />

0.4375 4-1/2 3 1-1/2<br />

0.4375 5 3-1/2 1-1/2<br />

0.4375 5-1/2 4 1-1/2<br />

0.4375 6 4-1/2 1-1/2<br />

0.4375 6-1/2 5 1-1/2<br />

0.4375 7 5-1/2 1-1/2<br />

0.4375 7-1/2 6 1-1/2<br />

0.4375 8 6-1/2 1-1/2<br />

0.4375 9 7-1/2 1-1/2<br />

0.4375 9-1/2 8 1-1/2<br />

0.4375 10 8-1/2 1-1/2<br />

12. HEAD SHAPE ROUND DOUBLE HEX<br />

13. HEAD DIMENSIONS (inches)<br />

Thickness -- 0.10<br />

Diameter 1.1 1.00<br />

14. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

15. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 2.7 GALVALUME ROUND W/SPIKES 2 NYLON<br />

ROUND/W/SPIKES 3 CARBON STEEL<br />

16. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

OPTIONAL<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

AIR WRENCH OR HANDSET TOOL (OPTIONAL)<br />

Other BX LITE DRIVE ELECTRIC IMPACT WRENCH/ELIMINATOR (OPTIONAL)<br />

17. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

Lightweight Concrete -- 375<br />

Gypsum -- 450<br />

Cementitious Wood Fiber -- 450<br />

18. ACCEPTED BY THE FOLLOWING CODES<br />

Lightweight Concrete<br />

FM, METRO-DADE COUNTY<br />

Gypsum<br />

FM, METRO-DADE COUNTY<br />

Cementitious Wood Fiber<br />

FM, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X<br />

NA = not applicable<br />

572


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

JOHNS MANVILLE INTERNATIONAL INC. OLYMPIC MANUFACTURING GROUP/NTB FASTENERS OLYMPIC MANUFACTURING GROUP<br />

LWC CR BASE SHEET FASTENER N.T.B. MAGNUM WITH & WITHOUT WIRES TOGGLE BOLT (STAINLESS STEEL)<br />

U.S. U.S. U.S.<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X<br />

X X X<br />

STEEL NYLON STAINLESS STEEL<br />

G-90 HOT DIPPED GALVANIZED & CR-10 NA NA<br />

TWO-PIECE RECTANGULAR -SPLIT BODY SPIRAL THREAD THREADED<br />

NA NA NA<br />

SHANK EXPANSION THREADED, SPIN WELD WITH & WITHOUT WIRES TOGGLE BOLT PLUS WING THRU PREDRILLED HOLE<br />

NA 1.75 NA NA 0.4375 2-1/2 1 1-1/2 0.215 4 2-1/2 1-1/2<br />

NA 1.20 NA NA 0.4375 3 1-1/2 1-1/2 0.215 6 4-1/2 1-1/2<br />

0.4375 3-1/2 2 1-1/2 0.215 7 5-1/2 1-1/2<br />

0.4375 4 2-1/2 1-1/2 0.215 8 6-1/2 1-1/2<br />

0.4375 4-1/2 3 1-1/2 0.215 10 8-1/2 1-1/2<br />

0.4375 5 3-1/2 1-1/2 0.215 12 10-1/2 1-1/2<br />

0.4375 5-1/2 4 1-1/2 0.215 14 12-1/2 1-1/2<br />

0.4375 6 4-1/2 1-1/2 0.215 16 14-1/2 1-1/2<br />

0.4375 6-1/2 5 1-1/2 0.215 18 16-1/2 1-1/2<br />

0.4375 7 5-1/2 1-1/2 0.215 20 18-1/2 1-1/2<br />

0.4375 7-1/2 6 1-1/2 0.215 22 20-1/2 1-1/2<br />

0.4375 8 6-1/2 1-1/2 0.215 24 22-1/2 1-1/2<br />

0.4375 8-1/2 7 1-1/2<br />

0.4375 9 7-1/2 1-1/2<br />

0.4375 9-1/2 8 1-1/2<br />

0.4375 10 8-1/2 1-1/2<br />

RECTANGULAR WITH ROUNDED CORNERS DOUBLE HEX ROUND TRUSS WITH #3 PHILLIPS<br />

NA 0.100 0.110<br />

1 X 1.3 1.00 0.435<br />

YES YES YES<br />

YES YES YES<br />

ROUND 2-3/4 GALVALUME ROUND W/SPIKES 2 NYLON ROUND 2 STAINLESS STEEL<br />

ROUND W/ SPIKES 3 CARBON STEEL ROUND 2 STEEL<br />

ROUND 2 PLASTIC<br />

ROUND 3 STAINLESS STEEL<br />

ROUND 3 STEEL<br />

ROUND 3 PLASTIC<br />

ROUND 3-1/2 STEEL<br />

NA OPTIONAL REQUIRED<br />

NA<br />

NA<br />

ELIMINATOR TOOL (OPTIONAL)<br />

MALLET (REQUIRED)<br />

ELECTRIC IMPACT WRENCH/ELIMINATOR (0PTIONAL)<br />

40 MIN. 375 600<br />

NA 450 600<br />

NA 400 600<br />

FM, UL, METRO-DADE COUNTY FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

FM, UL, METRO-DADE COUNTY FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

NA<br />

FM, METRO-DADE COUNTY<br />

YES YES YES<br />

X<br />

X<br />

573


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

1. COMPANY NAME OLYMPIC MANUFACTURING GROUP OLYMPIC MANUFACTURING GROUP<br />

2. PRODUCT NAME TOGGLE BOLT (CARBON STEEL) IRON-LOK TOGGLE BOLT<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. DECK TYPE:<br />

Lightweight Concrete X X<br />

Gypsum X X<br />

Cementitious Wood Fiber X X<br />

5. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes<br />

X<br />

6. MATERIAL TYPE CARBON STEEL CARBON STEEL<br />

7. COATING TYPE CR-10 CR-1O WITH IRON-LOK ADHESIVE<br />

8. SHANK TYPE THREADED THREADED<br />

9. POINT TYPE NA NA<br />

10. METHOD OF ATTACHMENT TOGGLE BOLT PLUS WING THRU PREDRILLED HOLE TOGGLE BOLT PLUS WING THRU PREDRILLED HOLE<br />

11. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.215 4 2-1/2 1-1/2 0.215 4 2-1/2 1-1/2<br />

0.215 6 4-1/2 1-1/2 0.215 6 4-1/2 1-1/2<br />

0.215 7 5-1/2 1-1/2 0.215 7 5-1/2 1-1/2<br />

0.215 8 6-1/2 1-1/2 0.215 8 6-1/2 1-1/2<br />

0.215 10 8-1/2 1-1/2 0.215 10 8-1/2 1-1/2<br />

0.215 12 10-1/2 1-1/2 0.215 12 10-1/2 1-1/2<br />

0.215 14 12-1/2 1-1/2 0.215 14 12-1/2 1-1/2<br />

0.215 16 14-1/2 1-1/2 0.215 16 14-1/2 1-1/2<br />

0.215 18 16-1/2 1-1/2 0.215 18 16-1/2 1-1/2<br />

0.215 20 18-1/2 1-1/2 0.215 20 18-1/2 1-1/2<br />

0.215 22 20-1/2 1-1/2 0.215 22 20-1/2 1-1/2<br />

0.215 24 22-1/2 1-1/2 0.215 24 22-1/2 1-1/2<br />

12. HEAD SHAPE ROUND TRUSS WITH #3 PHILLIPS ROUND TRUSS WITH #3 PHILLIPS<br />

13. HEAD DIMENSIONS (inches)<br />

Thickness 0.110 0.110<br />

Diameter 0.435 0.435<br />

14. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

15. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND 2 STAINLESS STEEL ROUND 2 STAINLESS STEEL<br />

ROUND 2 STEEL ROUND 2 STEEL<br />

ROUND 2 PLASTIC ROUND 2 PLASTIC<br />

ROUND 3 STAINLESS STEEL ROUND 3 STAINLESS STEEL<br />

ROUND 3 STEEL ROUND 3 STEEL<br />

ROUND 3 PLASTIC ROUND 3 PLASTIC<br />

ROUND 3-1/2 STEEL ROUND 3-1/2 STEEL<br />

16. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED REQUIRED<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

Other<br />

17. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

Lightweight Concrete 600 600<br />

Gypsum 600 600<br />

Cementitious Wood Fiber 600 600<br />

18. ACCEPTED BY THE FOLLOWING CODES<br />

Lightweight Concrete FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

Gypsum FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

Cementitious Wood Fiber<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

574


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

OLYMPIC MANUFACTURING GROUP OLYMPIC MANUFACTURING GROUP POWERS FASTENERS<br />

LITE-DECK OLYMPIC BASE SHEET FASTENER POWERS RAWL SPEED-LOCK TOGGLE<br />

U.S. U.S. U.S.<br />

X<br />

X<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

X X X<br />

X X X<br />

HARDENED CARBON STEEL STEEL CARBON STEEL & STAINLESS STEEL<br />

CR-10 G-90 HOT DIPPED GALVANIZED & CR-10 SC PERMA-SEAL FLUOROPOLYMER (ON CARBON STEEL BOLT ONLY)<br />

THREADED SPLIT BODY ANNULAR THREAD<br />

PINCH NA NA<br />

THREADED SHANK EXPANSION CLAMPING<br />

0.310 3 1 2 NA 1.75 NA NA 0.250 5 3-1/2 1-1/2<br />

0.310 4 2 2 NA 1.20 0.250 6 4-1/2 1-1/2<br />

0.310 5 3 2 0.250 7 5-1/2 1-1/2<br />

0.310 6 4 2 0.250 8 6-1/2 1-1/2<br />

0.310 8 6 2 0.250 9 7-1/2 1-1/2<br />

0.310 9 7 2 0.250 10 8-1/2 1-1/2<br />

0.310 10 8 2 0.250 12 10-1/2 1-1/2<br />

0.310 12 10 2 0.250 14 12-1/2 1-1/2<br />

ROUND #3 SQUARE DRIVE SC RECTANGULAR WITH ROUNDED CORNERS PHILLIPS FLAT HEAD #3 RECESS<br />

-- -- 0.042<br />

0.558 1 X 1.3 0.426<br />

YES NO YES<br />

YES YES YES<br />

ROUND 3 STEEL ROUND 2-3/4 G-90 GALVANIZED & ROUND 3 GALVALUME<br />

GALVALUME<br />

REQUIRED<br />

OPTIONAL<br />

P090, P060<br />

MALLET (REQUIRED)<br />

APPROPRIATE DRILL & BIT FOR BASE MATERIAL (REQUIRED)<br />

NA 40 MIN. 995<br />

450 NA 620<br />

450 NA 570<br />

FM, UL, METRO-DADE COUNTY<br />

FM<br />

FM, UL, METRO-DADE COUNTY FM, UL, METRO-DADE COUNTY FM<br />

FM, UL, METRO-DADE COUNTY NA FM<br />

YES YES YES<br />

X<br />

X<br />

575


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

1. COMPANY NAME POWERS FASTENERS SFSSTADLER INC.<br />

2. PRODUCT NAME POWERS RAWL POWERLITE INSUL-LILTE<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. DECK TYPE:<br />

Lightweight Concrete X X<br />

Gypsum X X<br />

Cementitious Wood Fiber X X<br />

5. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

6. MATERIAL TYPE DUPONT ZYTEL NYLON NYLON<br />

7. COATING TYPE NA NA<br />

8. SHANK TYPE HIGH THREAD WITH TAPPERED ROOT SPIRAL THREAD<br />

9. POINT TYPE SHARP GIMLET<br />

10. METHOD OF ATTACHMENT THREADED, SUBSTRATE COMPACTION SUBSTRATE COMPACTION<br />

11. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.675 2 1/2 1-1/2 0.430 2 1/2 1-1/2<br />

0.675 2-1/2 1 1-1/2 0.430 2-1/2 1 1-1/2<br />

0.675 3 1-1/2 1-1/2 0.430 3 1-1/2 1-1/2<br />

0.675 3-1/2 2 1-1/2 0.430 3-1/2 2 1-1/2<br />

0.675 4 2-1/2 1-1/2 0.430 4 2-1/2 1-1/2<br />

0.675 4-1/2 3 1-1/2 0.430 4-1/2 3 1-1/2<br />

0.675 5 3-1/2 1-1/2 0.430 5 3-1/2 1-1/2<br />

0.675 5-1/2 4 1-1/2 0.430 5-1/2 4 1-1/2<br />

0.675 6 4-1/2 1-1/2 0.430 6 4-1/2 1-1/2<br />

0.675 6-1/2 5 1-1/2 0.430 7 5-1/2 1-1/2<br />

0.675 7 5-1/2 1-1/2 0.430 8 6-1/2 1-1/2<br />

0.675 7-1/2 6 1-1/2 0.430 9 7-1/2 1-1/2<br />

0.675 8 6-1/2 1-1/2 0.430 10 9-1/2 1-1/2<br />

0.675 8-1/2 7 1-1/2<br />

0.675 9 7-1/2 1-1/2<br />

0.675 9-1/2 8 1-1/2<br />

0.675 10 8-1/2 1-1/2<br />

0.675 11 9-1/2 1-1/2<br />

0.675 12 10-1/2 1-1/2<br />

0.675 13 11-1/2 1-1/2<br />

0.675 14 12-1/2 1-1/2<br />

12. HEAD SHAPE 1/4" SQUARE DRIVE RECESS ROUND<br />

13. HEAD DIMENSIONS (inches)<br />

Thickness 0.134 0.120<br />

Diameter 1.000 1.000<br />

14. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

15. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND BARBED 2 GALVALUME ROUND BARBED 2 GALVALUME<br />

ROUND BARBED 3 GALVALUME ROUND BARBED 3 GALVALUME<br />

16. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

Other APP. DRILL & BIT FOR BASE MAT'L/ IMPACT WRENCH REQUIRED IMPACT WRENCH<br />

17. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

Lightweight Concrete -- 280<br />

Gypsum 540 600<br />

Cementitious Wood Fiber 595 450<br />

18. ACCEPTED BY THE FOLLOWING CODES<br />

Lightweight Concrete FM FM<br />

Gypsum FM FM<br />

Cementitious Wood Fiber FM FM<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X<br />

NA = not applicable<br />

576


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

SFS STADLER INC. SFS STADLER INC SFS STADLER INC.<br />

FM-90 BASE PLY TPR-THE PEEL RIVET BASE-LOK<br />

U.S. ISRAEL U.S.<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X<br />

X<br />

X<br />

STEEL ALUMINUM ALLOY NYLON<br />

HOT DIPPED G-90 GALVANIZED & URETHANE NA NA<br />

TWO-PIECE RECTANGULAR HOLLOW RIVET BODY HIGH PROFILE THREAD<br />

NA PIERCING MANDRELL DRILL<br />

SHANK EXPANSION CLAMPING THREADED<br />

NA 1-/710 NA NA 0.250 1-1/4 1/4 1 0.562 1-5/8 NA 1-1/2<br />

0.250 2 1 1<br />

0.250 3 2 1<br />

0.250 4 3 1<br />

0.250 5 4 1<br />

0.250 6 5 1<br />

0.250 7 6 1<br />

0.250 8 7 1<br />

0.250 9 8 1<br />

0.250 10 9 1<br />

ROUND LOW PROFILE MUSHROOM ROUND<br />

-- 0.075 0.059<br />

2.75 0.480 3.000<br />

NO YES NO<br />

YES YES --<br />

ROUND 2 GALVALUME<br />

ROUND 3 GALVALUME<br />

MAGNETIC DRIVER (REQUIRED)<br />

OPTIONAL<br />

REQUIRED<br />

REQUIRED<br />

OPTIONAL<br />

90 MIN. 509 186<br />

NA 507 --<br />

NA 374 165<br />

FM, METRO-DADE COUNTY FM FM<br />

FM<br />

FM<br />

FM, METRO-DADE COUNTY<br />

YES YES YES<br />

577


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

1. COMPANY NAME SIMPLEX SIMPLEX<br />

2. PRODUCT NAME BASE-LOC TUBE-LOK RL<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. DECK TYPE:<br />

Lightweight Concrete X X<br />

Gypsum X X<br />

Cementitious Wood Fiber X X<br />

5. USED WITH:<br />

Insulation Attachment<br />

X<br />

Built-Up Membranes X X<br />

Single-Ply Membranes X X<br />

6. MATERIAL TYPE CARBON NYLON GLASS FIBER RESIN CARBON STEEL<br />

7. COATING TYPE NA RUST-LOK<br />

8. SHANK TYPE HIGH PROFILE SPIRAL THREAD BARBED<br />

9. POINT TYPE SPADE SHOVEL DRILL POINT CHISEL<br />

10. METHOD OF ATTACHMENT THREADED FISH HOOK & FRICTION<br />

11. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.562 1.7 0.0625 1.5 0.168 1 0 1<br />

0.168 1-3/4 1/4 1-1/2<br />

0.168 2-1/2 1 1-1/2<br />

0.168 3 1-1/2 1-1/2<br />

0.168 3-1/2 2 1-1/2<br />

0.168 4-1/2 3 1-1/2<br />

0.168 5-1/2 4 1-1/2<br />

0.168 6-1/2 5 1-1/2<br />

12. HEAD SHAPE ROUND ROUND<br />

13. HEAD DIMENSIONS (inches)<br />

Thickness 0.125 0.037<br />

Diameter 1.000 1.000<br />

14. PLATES<br />

Required (yes/no) NA NO<br />

Available From Manufacturer (yes/no) NA YES<br />

15. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

PARABOLIC 2 GALVALUME<br />

PARABOLIC 3 GALVALUME<br />

16. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required) REQUIRED WITH CLUTCH NA<br />

Installation Tool With Screw Gun (optional/required) OPTIONAL NA<br />

Special Tool Needed (optional/required) OPTIONAL NA<br />

Other NA NA<br />

17. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

Lightweight Concrete 186 120.2<br />

Gypsum -- 364.8<br />

Cementitious Wood Fiber 191.5 115.0<br />

18. ACCEPTED BY THE FOLLOWING CODES<br />

Lightweight Concrete FM, DADE COUNTY DADE COUNTY<br />

Gypsum DADE COUNTY DADE COUNTY<br />

Cementitious Wood Fiber FM, DADE COUNTY DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED X X<br />

NA = not applicable<br />

578


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

SIMPLEX SIMPLEX TREMCO INC.<br />

TRUBE-LOK EGYD TUBE-LOK B BASE SHEET FASTENER ASSEMBLY<br />

U.S. U.S. U.S.<br />

X X X<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

X X X<br />

X X X<br />

CARBON STEEL CARBON STEEL STEEL<br />

ELECTRO GALVANIZED YELLOW DICHROMATE BRIGH CR-10 FLUOROCARBON<br />

BARBED BARBED SPLIT BODY<br />

CHISEL CHISEL NA<br />

FISH HOOK & FRICTION FISH HOOK & FRICTION SHANK EXPANSION<br />

0.168 1 0 1 0.168 1 0 1 NA 1.75<br />

0.168 1-3/4 1/4 1-1/2 0.168 1-3/4 1/4 1-1/2 NA 1.20<br />

0.168 2-1/2 1 1-1/2 0.168 2-1/2 1 1-1/2<br />

0.168 3 1-1/2 1-1/2 0.168 3 1-1/2 1-1/2<br />

0.168 3-1/2 2 1-1/2 0.168 3-1/2 2 1-1/2<br />

0.168 4-1/2 3 1-1/2 0.168 4-1/2 3 1-1/2<br />

0.168 5-1/2 4 1-1/2 0.168 5-1/2 4 1-1/2<br />

0.168 6-1/2 5 1-1/2 0.168 6-1/2 5 1-1/2<br />

ROUND ROUND RECTANGULAR W/ROUND CORNER W/ROUND PLATE<br />

0.037 0.037<br />

1.000 1.000 2.75<br />

NO NO YES<br />

YES YES YES<br />

PARABOLIC 2 GALVALUME PARABOLIC 2 GALVALUME ROUND 2-3/4<br />

PARABOLIC 3 GALVALUME PARABOLIC 3 GALVALUME<br />

NA<br />

NA<br />

NA<br />

NA<br />

NA<br />

NA<br />

NA NA HAMMER / MALLET<br />

120.2 120.2 40 MIN.<br />

364.8 364.8<br />

115.0 115.0<br />

DADE COUNTY DADE COUNTY FM, UL, METRO-DADE COUNTY<br />

DADE COUNTY<br />

DADE COUNTY<br />

DADE COUNTY<br />

DADE COUNTY<br />

YES YES YES<br />

X<br />

X<br />

579


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

1. COMPANY NAME TRU-FAST CORPORATION U.S. INTEC<br />

2. PRODUCT NAME TL (TECTUM LIGHTWEIGHT) DRILL-TEC LITE DECK<br />

3. COUNTRY OF MANUFACTURE U.S. U.S.<br />

4. DECK TYPE:<br />

Lightweight Concrete X X<br />

Gypsum X X<br />

Cementitious Wood Fiber X X<br />

5. USED WITH:<br />

Insulation Attachment X X<br />

Built-Up Membranes<br />

X<br />

Single-Ply Membranes<br />

X<br />

6. MATERIAL TYPE DUPONT ZYTEL NYLON DUPONT ZYTEL NYLON<br />

7. COATING TYPE NA NA<br />

8. SHANK TYPE SPIRAL THREAD SPIRAL THREAD<br />

9. POINT TYPE GIMLET GIMLET<br />

10. METHOD OF ATTACHMENT THREADED, SUBSTRATE COMPACTION THREADED, SUBSTRATE COMPACTION<br />

11. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /<br />

FASTENING RANGE THICKNESS (inches) / DECK<br />

PENETRATION (inches)<br />

0.430 2 1/2 1-1/2 0430 2 -- 1-1/2<br />

0.430 2-1/2 1 1-1/2 0430 2-1/2 -- 1-1/2<br />

0.430 3 1-1/2 1-1/2 0430 3 -- 1-1/2<br />

0.430 3-1/2 2 1-1/2 0430 3-1/2 -- 1-1/2<br />

0.430 4 2-1/2 1-1/2 0430 4 -- 1-1/2<br />

0.430 4-1/2 3 1-1/2 0430 4-1/2 -- 1-1/2<br />

0.430 5 3-1/2 1-1/2 0430 5 -- 1-1/2<br />

0.430 5-1/2 4 1-1/2 0430 5-1/2 -- 1-1/2<br />

0.430 6 4-1/2 1-1/2 0430 6 -- 1-1/2<br />

0.430 6-1/2 5 1-1/2 0430 6-1/2 -- 1-1/2<br />

0.430 7 5-1/2 1-1/2 0430 7 -- 1-1/2<br />

0.430 7-1/2 6 1-1/2 0430 7-1/2 -- 1-1/2<br />

0.430 8 6-1/2 1-1/2 0430 8 -- 1-1/2<br />

0.430 8-1/2 7 1-1/2 0430 8-1/2 -- 1-1/2<br />

0.430 9 7-1/2 1-1/2 0430 9 -- 1-1/2<br />

0.430 9-1/2 8 1-1/2 0430 9-1/2 -- 1-1/2<br />

0.430 10 8-1/2 1-1/2 0430 10 -- 1-1/2<br />

12. HEAD SHAPE ROUND, 1/4-IN. RECESS ROUND, 1/4-IN. RECESS<br />

13. HEAD DIMENSIONS (inches)<br />

Thickness 0.120 0.120<br />

Diameter 1.00 1.00<br />

14. PLATES<br />

Required (yes/no) YES YES<br />

Available From Manufacturer (yes/no) YES YES<br />

15. PLATE SHAPE / DIMENSIONS (inches) / MATERIAL<br />

ROUND BARBED 2 GALVALUME ROUND BARBED 3 GALVALUME<br />

ROUND BARBED 3 GALVALUME<br />

16. INSTALLATION EQUIPMENT<br />

Screw Gun (optional/required)<br />

Installation Tool With Screw Gun (optional/required)<br />

Special Tool Needed (optional/required)<br />

Other IMPACT WRENCH, ELECTRIC DRILL (OPTIONAL) IMPACT WRENCH, ELECTRIC DRILL (REQUIRED)<br />

17. AVERAGE PULLOUT RESISTANCE (lbs.)<br />

Lightweight Concrete 280 280<br />

Gypsum 600 600<br />

Cementitious Wood Fiber 450 450<br />

18. ACCEPTED BY THE FOLLOWING CODES<br />

Lightweight Concrete<br />

FM<br />

Gypsum FM FM, METRO-DADE COUNTY<br />

Cementitious Wood Fiber FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY<br />

19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES<br />

20. SEE APPENDIX IF CHECKED<br />

NA = not applicable<br />

580


<strong>Roof</strong> Fasteners: Lightweight Concrete, Gypsum,<br />

or Cementitious Wood Fiber Decks<br />

U.S. INTEC<br />

DRILL TECII TL<br />

U.S.<br />

U.S. INTEC<br />

DRILL TEC II ES<br />

U.S.<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

NYLON<br />

THREADED<br />

GIMLET<br />

THREADED, SUBSTRATE COMPACTION<br />

X<br />

X<br />

GALVANIZED STEEL<br />

ELASTOMERIC POLYMER<br />

TWO-PIECE RECTANGULAR<br />

SHANK EXPANSION<br />

0430 2 -- 1-1/2 NA 1.2 NA NA<br />

0430 2-1/2 -- 1-1/2<br />

0430 3 -- 1-1/2<br />

0430 3-1/2 -- 1-1/2<br />

0430 4 -- 1-1/2<br />

0430 4-1/2 -- 1-1/2<br />

0430 5 -- 1-1/2<br />

0430 5-1/2 -- 1-1/2<br />

0430 6 -- 1-1/2<br />

0430 6-1/2 -- 1-1/2<br />

0430 7 -- 1-1/2<br />

0430 7-1/2 -- 1-1/2<br />

0430 8 -- 1-1/2<br />

0430 8-1/2 -- 1-1/2<br />

0430 9 -- 1-1/2<br />

0430 9-1/2 -- 1-1/2<br />

0430 10 -- 1-1/2<br />

ROUND, 1/2 IN. RECESS<br />

0.120<br />

1.00<br />

YES<br />

YES<br />

YES<br />

YES<br />

ROUND BARBED 3 GALVALUME ROUND 2-3/4 GALVALUME OR G 90<br />

COMPACT WRENCH, ELECTRIC DRILL<br />

280 40 MIN.<br />

600 40 MIN.<br />

450 NA<br />

FM, METRO-DADE COUNTY<br />

FM, METRO-DADE COUNTY<br />

YES<br />

FM, METRO-DADE COUNTY<br />

581


Appendix, <strong>Roof</strong> Fasteners<br />

CELOTEX CORPORATION<br />

Anchorbond #12 HWH requires recessed 2 7/8-inch<br />

plate only. Anchorbond #12 not available in #3<br />

phillips head in 6-inch lengths.<br />

CONSTRUCTION FASTENERS, INC., DEKFAST<br />

PRODUCT GROUP<br />

Fasteners, steel decks: Dekfast #12 HWH requires<br />

recessed 2 7/8-inch hex plate only. Stainless steel<br />

(Trimrite) screws require special plates.<br />

Fasteners, wood decks: one-quarter-inch<br />

penetration through the plywood is required on 3/4-in.<br />

plywood decks. Stainless steel (Trimrite) screws<br />

require special plates. Pull-out data for 2-inch pine<br />

plank reflects a fastener length that provides full<br />

penetration throught the plank.<br />

Fasteners, lightweight concrete decks: Deklite<br />

pull-out data is based on the following: (a) lightweight<br />

concrete, 2 1/2-in. penetration, (b) gypsum, 2-in.<br />

penetration, (c) cementitious wood fiber, 2-in.<br />

penetration.<br />

GAF MATERIALS CORPORATION<br />

For GAFTITE wood deck fasteners, 1/2-inch<br />

penetration is required through plywood.<br />

The Fluted Concrete Nail is installed by driving<br />

in<strong>to</strong> pre-drilled hole with carpenter or small sledge<br />

hammer (e.g., two lbs.). For GAFTITE Toggle Bolts<br />

(carbon and stainless steel) and Iron-Lok Toggle Bolt,<br />

pullout values are expected averages. Actual pullouts<br />

may vary. 1.2-in. base sheet fastener is<br />

recommended.<br />

Iron-Lok Toggle Bolts can be used for any<br />

application, but primary use is for membrane<br />

attachment of mechanically fastened single-plies.<br />

Fac<strong>to</strong>ry-applied adhesives on threads prevent<br />

loosening of <strong>to</strong>ggle bolt assembly due <strong>to</strong> membrane<br />

flutter. Lite-Deck Fasteners can be used in specially<br />

designed batten strip.<br />

GAFTITE #14-10 and #12-11 fasteners are<br />

available with a 1/4-in. hex head design.<br />

ITW BUILDEX<br />

ITW Buildex Accutrac roof insulation fastening <strong>to</strong>ol<br />

installs fasteners and plates in a one-step continuous<br />

process. The Accutrac <strong>to</strong>ol was designed exclusively<br />

<strong>to</strong> be used with ITW Buildex Accutrac fasteners and<br />

plates.<br />

The ITW Buildex Lite Weight Concrete<br />

Fastening System combines new packaging that<br />

doubles as a carrying pouch, a stand-up magnetic<br />

driver, and an assembled fastener and plate.<br />

The Hextra Plus and <strong>Roof</strong>grip Plus systems<br />

conbine the Hextra and <strong>Roof</strong>grip fasteners with a 3"<br />

round galvalume plate in a preassembled form. The<br />

Accufast <strong>to</strong>ol installs the preassembled parts from a<br />

stand-up position.<br />

JOHNS MANVILLE INTERNATIONAL, INC.<br />

The UltraFast, UltraGard AP, and High Load fastener<br />

lines are available as separate screws and plates or<br />

as pre-assembled screws and plates as in the<br />

UltraFast ASAP, UltraGard APB ASAP, and High Load<br />

ASAP product line.<br />

The UltraFast and UltraFast ASAP fastener lines<br />

are available with either a 1/4-inch hex head or a #3<br />

phillips head.<br />

NATIONAL NAIL CORP.<br />

Round-Top and R/S Round Top round heads<br />

eliminate tearing or cutting of felt and/or insulation<br />

roofing material.<br />

Plasti-Top fasteners are not <strong>to</strong> be used on hot<br />

built-up roofs or if application temperatures exceed<br />

190 F for more than two minutes.<br />

Plasti-Cap fasteners are not <strong>to</strong> be used on hot<br />

built-up roofs or if application temperatures exceed<br />

170 F for more than three minutes.<br />

Ardox H.T. Galvanized Concrete Fasteners are<br />

available in 50-lb. car<strong>to</strong>ns or 100-count packages.<br />

POWERS RAWL, POWERS FASTENERS, INC.<br />

The Woodie and specially designed Woodie plates<br />

are for attachment of insulation, single-ply<br />

membranes, or standing-seam metal roofing clips <strong>to</strong><br />

oriented strand board (OSB) or plywood roof decks.<br />

#12 Hex Washer Head Deck Screws may be used<br />

with Powers Rawl 3-in. round recessed plates only.<br />

Speed Lock Toggles may be used for all deck<br />

types and are preassembled with 3-in. round plates<br />

for insulation attachment.<br />

#12 Deck Screws are also available preassembled<br />

<strong>to</strong> insulation plates.<br />

For further details and technical information on<br />

roofing fasteners and other anchoring and fastening<br />

systems, please consult the Powers Rawl Fastening<br />

Systems Design Manual published by Powers<br />

Fasteners, Inc.<br />

582


Steel Deck: deck screws should penetrate<br />

through a minimum 3/4" per FMRC 1-29.<br />

Wood Deck: deck screws should penetrate<br />

through a minimum 1/4" in plywood decks that are<br />

3/4" thick per FMRC 1-29.<br />

SIMPLEX NAILS & FASTENERS, INC.<br />

Abbreviation Chart:<br />

Shank Type / Nail Finish<br />

B/ = Barbed Shank is recommended when it is<br />

installed in<strong>to</strong> a hard species of wood, or if<br />

a high pull out resistance is not desired<br />

AG/ = Annular Grooved is recommended when it<br />

is installed in<strong>to</strong> any type of wood, or if the<br />

appropriate building codes require a high<br />

pull out resistance<br />

/B = Bright Finish is recommended if it will not<br />

be exposed <strong>to</strong> a corrosive environment.<br />

/EGYD = Electro Galvanized Yellow Dichromate is<br />

recommended if it is exposed <strong>to</strong> a<br />

moderately corrosive environment<br />

/RL<br />

= Rust-Lok is recommended if it is exposed <strong>to</strong><br />

a highly corrosive environment<br />

EGS- = Electro Galvanized Steel is recommended<br />

if it is exposed <strong>to</strong> a moderately corrosive<br />

environment<br />

SS- = Stainless Steel is recommended if it is<br />

exposed <strong>to</strong> a highly corrosive<br />

environment<br />

Wood Deck Nails:<br />

The 3/4" plywood average pull out resistance was<br />

performed by the American Plywood <strong>Association</strong> in<br />

accordance <strong>to</strong> the American Plywood <strong>Association</strong>’s<br />

testing procedure. The average pullout resistance in<br />

a nominal 2" pine plank was done in the Simplex Nails<br />

& Fasteners Testing Lab. Rust-Lok is the priority<br />

coating that will pass the thousand hour salt spray<br />

rust test.<br />

Original Round Metal Caps Nails are unique <strong>to</strong> the<br />

roofing industry due <strong>to</strong> the fact that it is the only cap<br />

nail that has the nail and the cap welded <strong>to</strong>gether <strong>to</strong><br />

prevent the nail from backing through the roofing<br />

membrane. These nails are used <strong>to</strong> secure base<br />

sheets <strong>to</strong> the deck, flashing behind counter flashing,<br />

back nailing of roof membrane, thin insulation <strong>to</strong> a<br />

wood deck and various other miscellaneous roofing<br />

tasks.<br />

Insulation Round Metal Cap Nails are designed with<br />

wider shanks and longer lengths in order <strong>to</strong> install all<br />

types of roofing insulation in<strong>to</strong> wood decks.<br />

Economy Round Metal Cap Nails is designed <strong>to</strong> be<br />

less expensive by using friction <strong>to</strong> hold the shank <strong>to</strong><br />

the cap instead of welding the shank <strong>to</strong> the cap. It<br />

should be used in situations that would not would not<br />

permit the nail <strong>to</strong> back through the roofing membrane.<br />

Square Head Metal Cap Nails are designed <strong>to</strong> be<br />

strong and economical. It has an extra strong cap<br />

welded <strong>to</strong> the shank.<br />

Plex-Cap Plastic Cap Nails are designed <strong>to</strong> be<br />

affordable and increase the rupture values of softer<br />

building products. It should be used <strong>to</strong> secure roofing<br />

felt, insulation and polyfilm for temporary roofing <strong>to</strong><br />

wood decks.<br />

Coil <strong>Roof</strong>ing Nails are designed with a high wire that<br />

will allow it <strong>to</strong> fit all types of pneumatic nail guns. They<br />

have 120 nails per coils and 60 coils per box.<br />

Concrete Deck Nails:<br />

The Zanchor Drive Nails average pull out resistance<br />

was performed by Law Engineering, Inc. in<br />

accordance <strong>to</strong> the ASTM E-488-90 testing procedure<br />

using 4,000 psi concrete.<br />

Zanchor Drive Nails are designed <strong>to</strong> fit in <strong>to</strong> a predrilled<br />

1/4 inch hole and with a termination bar or the<br />

Simplex 2 inch & 3 inch plate in order <strong>to</strong> hold the base<br />

flashing, base sheet or insulation board in<strong>to</strong> structural<br />

concrete, brick or mortar.<br />

Masonry Round Metal Cap Nails are designed with a<br />

wide fluted hardened steel shank, welded <strong>to</strong> a<br />

hardened steel cap. They should be used <strong>to</strong> secure<br />

flashing behind counter flashing and various other<br />

miscellaneous roofing tasks in<strong>to</strong> bricks or masonry<br />

joints.<br />

Lightweight Concrete, Gypsum, or Cementitious Wood<br />

Fiber Decks Nails:<br />

Base-Loks are designed <strong>to</strong> give a superior hold for<br />

base sheets while minimizing the destruction <strong>to</strong> the<br />

deck, by requiring less fasteners than any equivalent<br />

method. The Base-Lok’s average pull out resistance<br />

was performed by Trinity Engineering, Inc. in<br />

accordance with Dade County Pro<strong>to</strong>col PA 105 (A)<br />

and 117 (A) testing procedure. The Base-Lok has<br />

been tested with most of the leading base sheets for<br />

its rupture value and these results are available from<br />

Simplex upon request. Base-Loks should be used <strong>to</strong><br />

secure base sheets <strong>to</strong> low and steep sloped<br />

cementitious wood fiber, gypsum, cellular and<br />

lightweight concrete decks with the use of a clutched<br />

slow speed drill and a standard 1/4" hex head bit.<br />

Tube-Loks are designed <strong>to</strong> secure felts, base sheets,<br />

insulation, shingles, slate, <strong>to</strong> low and steep<br />

583


sloped cementitious wood fiber, gypsum, cellular<br />

and lightweight concrete decks. The Tube-Lok’s<br />

average pull out resistance was performed<br />

accordance with Dade County Pro<strong>to</strong>col PA 117 (A)<br />

testing procedure. Complete installation instruction<br />

are available from Simplex upon request.<br />

584


Section 4<br />

<strong>Roof</strong> Cements & Adhesives,<br />

and Coatings


Information on Section 4: <strong>Roof</strong> Cements & Adhesives, and Coatings<br />

General Information<br />

Section 4: <strong>Roof</strong> Cements & Adhesives and <strong>Roof</strong><br />

Coatings in the 2001 edition of NRCA’s Low-Slope<br />

<strong>Roof</strong>ing Materials Guide is divided in<strong>to</strong> three parts, as<br />

follows:<br />

• Part 1: <strong>Roof</strong> Cements & Adhesives and<br />

<strong>Roof</strong> Coatings, General Information<br />

• Part 2: <strong>Roof</strong> Cements & Adhesives,<br />

Technical Data<br />

• Part 3: <strong>Roof</strong> Coatings, Technical Data<br />

Specific listing information included in Part 1: <strong>Roof</strong><br />

Cements & Adhesives and <strong>Roof</strong> Coatings, General<br />

Information is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Product description<br />

4. Uses<br />

5. Application method(s)<br />

6. <strong>Roof</strong> system description<br />

7. Country of manufacture<br />

8. Year of first commercial use<br />

9. Sales information contact<br />

10. Technical information contact<br />

11. See appendix<br />

In Part 2: <strong>Roof</strong> Cements & Adhesives, Technical Data<br />

specific listing information is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Complies with (applicable ASTM standard)<br />

4. Fire resistance classification<br />

5. See appendix<br />

Reporting of compliance information in Item 3 is<br />

based upon the following American Society for<br />

Testing and Materials (ASTM) standards:<br />

• ASTM D2822, titled “Standadrd<br />

Specification for Asphalt <strong>Roof</strong> Cement”<br />

• ASTM D3019, titled “Standard<br />

Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non Fibered,<br />

Asbes<strong>to</strong>s Fibered, and Non Asbes<strong>to</strong>s<br />

Fibered”<br />

• ASTM D3747, titled “Standard<br />

Specification for Emulsified Asphalt<br />

Adhesive for Adhering <strong>Roof</strong> Insulation”<br />

•<br />

• ASTM D4022, titled “Standard Specification for<br />

Coal Tar Cement, Asbes<strong>to</strong>s Containing”<br />

• ASTM D4586, titled “Standard Specification<br />

for Asphalt <strong>Roof</strong> Cement, Asbes<strong>to</strong>s-Free”<br />

In Part 3: <strong>Roof</strong> Coatings, Technical Data specific<br />

listing information is as follows:<br />

1. Company name<br />

2. Product name<br />

3. Complies with (applicable ASTM standard)<br />

4. Fire resistance classification<br />

5. See appendix<br />

Reporting of compliance information in Item 3 is<br />

based upon the following American Society for<br />

Testing and Materials (ASTM) standards:<br />

• ASTM C836, titled “Standard Specification<br />

for High Solids Content, Cold Liquid-Applied<br />

Elas<strong>to</strong>meric Waterproofing Membrane for<br />

Use with Separate Wearing Surface”<br />

• ASTM C957, titled “Standard Specification<br />

for High Solids Content, Cold Liquid-Applied<br />

Elas<strong>to</strong>meric Waterproofing Membarne with<br />

Integral Wearing Surface”<br />

• ASTM D41, titled “Standard Specification<br />

for Asphalt Primers Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing”<br />

• ASTM D43, titled “ Standard Specification<br />

for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing”<br />

• ASTM D1187, titled “Standard Specification<br />

for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal”<br />

• ASTM D1227, titled “Standard Specification<br />

for Emulsified Asphalt Used as a Protective<br />

Coating for <strong>Roof</strong>ing”<br />

• ASTM D2923, titled “Standard Specification<br />

for Asphalt <strong>Roof</strong> Coatings”<br />

• ASTM D2824, titled “Standard Specification<br />

for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered,<br />

and Fibered without Asbes<strong>to</strong>s”<br />

• ASTM D3468, titled “Standard<br />

Specification for Liquid-Applied Neoprene<br />

and Chlorosulfonated Polyethylene Used<br />

in <strong>Roof</strong>ing and Waterproofing”<br />

587


Information on Section 4: <strong>Roof</strong> Cements & Adhesives, and Coatings<br />

• ASTM D4479, titled “Standard<br />

Specification for Asphalt <strong>Roof</strong> Coatings --<br />

Asbes<strong>to</strong>s Free”<br />

• ASTM D6083, titled “Standard<br />

Specification for Liquid Applied Acrylic<br />

Coating Used in <strong>Roof</strong>ing”<br />

Users of the guide who are interested in additional<br />

information regarding roof cements & adhesives and<br />

roof coatings are encouraged <strong>to</strong> refer <strong>to</strong> The NRCA<br />

<strong>Roof</strong>ing and Waterproofing Manual, Fifth Edition.<br />

Section 4: <strong>Roof</strong> Cements and Coatings in the 2000<br />

edition of NRCA’s Low-Slope <strong>Roof</strong>ing Materials Guide<br />

provides a comprehensive listing of cements and<br />

coatings used in low-slope roofing. In addition, it<br />

provides information on cold-applied roof systems<br />

that employ coating products or cements as the<br />

primary weatherproofing medium and, in some<br />

instances, adhesive and stabilizing properties.<br />

An index of the manufacturers included in Section 4:<br />

<strong>Roof</strong> Cements & Adhesives and Coatings and<br />

locations of their specific products within this section<br />

immediately follows this section.<br />

588


Index <strong>to</strong> <strong>Roof</strong> Cements and Adhesive, and Coatings<br />

INCOMPLETE DATA<br />

CEMENTS & ADHESIVES,<br />

AND COATINGS<br />

INCOMPLETE DATA<br />

CEMENTS & ADHESIVES,<br />

AND COATINGS<br />

ALCM 592 833 GARDNER ASPHALT CORP/APOC 607 833<br />

7301 Bessemer Avenue 638 DIVISION 648<br />

Cleveland, OH 44127 668 P.O. Box 5449 686<br />

800/556-8030 Tampa, FL 33675-5449<br />

FAX: 216/341-5833 FAX: 813/248-6768<br />

E-mail: sales@alum.com<br />

Web:<br />

E-mail:<br />

Web:<br />

ALCO-NVC, INC. 594 833 GARLAND COMPANY, INC. 610<br />

P.O. Box 14001 639 3800 E. 91st Street 651<br />

Detroit, MI 48214 670 Cleveland, OH 44105 689<br />

800/323-0029 216/641-7500<br />

FAX: 313/331-4726 FAX: 216/641-0633<br />

E-mail: alconvc@aol.com<br />

E-mail:<br />

Web: www.alconvc.com<br />

Web:<br />

AMERICAN TAR COMPANY 595 GMX, INC. 612<br />

Division of Fields Company, LLC 641 9105 Way Avenue 692<br />

2240 Taylor Way 671 Cleveland, OH 44105<br />

Tacoma, WA 98421 216/641-7502<br />

253/627-4099 FAX: 216/641-0633<br />

FAX: 253/627-3859<br />

E-mail:<br />

E-mail:<br />

Web:<br />

ANDEK CORP. 597 HENRY COMPANY 613<br />

P.O. Box 392 641 (includes Bakor, Grundy, Monsey Bakor 653<br />

850 Glen Avenue 675 2911 Slauson Avenue 693<br />

Moores<strong>to</strong>wn, NJ 08057 Hunting<strong>to</strong>n, CA 90255<br />

888/88ANDEK 223/583-5000<br />

FAX: 888/44ANDEK FAX: 223/582-6429<br />

E-mail: andekcorp.@aol.com<br />

Web:<br />

CONKLIN CO. 598 KARNAK CORPORATION 619<br />

P.O. Box 155 675 330 Central Avenue 659<br />

Shakopee, MN 55379-0155 Clark, NJ 07066 700<br />

800/888-8838 732/388-0300 800/526-4236<br />

FAX: 952/496-4285 FAX: 732/388-9422<br />

E-mail: marketing@conklin.com<br />

E-mail:<br />

Web: www.conklin.com<br />

Web: www.karnakcorp.com<br />

DEWITT PRODUCTS CO. 598 KOKEM PRODUCTS INC. 623<br />

5860 Plumer 642 4432 N.E. Davis 703<br />

Detroit, MI 48209 675 Portland, OR 97213<br />

313/554-0575 800/962-8599 503/235-9206<br />

FAX: 313/554-2171 FAX: 503/235-9206<br />

E-mail:<br />

E-mail:<br />

Web: ww.dewitt@globalbiz.com<br />

Web:<br />

ECOLOGY ROOF SYSTEMS 600 METALRYLICS ACRYLIC-POLYESTER 623<br />

505 N. Tustin Avenue #188 643 ROOFING PRODUCTS 661<br />

Santa Ana, CA 92705 677 142 N. 27th Street 703<br />

714/972-1001 San Jose, CA 95116<br />

FAX: 714/972-1079 408/280-7733<br />

E-mail: FAX: 408/280-6329<br />

Web: www.ecologyroofsystems.com<br />

Web: www.metacrylics.com<br />

FIELDS COMPANY, LLC 602 NEOGARD div. of JONES BLAIR 625<br />

2240 Taylor Way 644 6900 Maple Ave. 705<br />

Tacoma, WA 98421 679 Dallas, TX 75235<br />

253/627-4098 800/321-6588<br />

FAX: 253/383-2181 FAX: 214/357-7532<br />

E-mail:<br />

E-mail: neogard@neogard.com<br />

Web:<br />

Web:<br />

GAF MATERIALS CORP. 605 REPUBLIC POWDERED METALS 625 833<br />

1361 Alps Road 647 3735 Green Road 705<br />

Wayne, NJ 07470 685 Beachwood, OH 44122<br />

973/628-3000 800/766-3411 800/551-7081<br />

FAX: 973/628-3451 FAX: 888/742-1759<br />

E-mail:<br />

E-mail:<br />

Web: www.gaf.com<br />

Web:<br />

589


Index <strong>to</strong> <strong>Roof</strong> Cements and Adhesive, and Coatings<br />

INCOMPLETE DATA<br />

CEMENTS & ADHESIVES,<br />

AND COATINGS<br />

INCOMPLETE DATA<br />

CEMENTS & ADHESIVES,<br />

AND COATINGS<br />

SOMAY PRODUCTS, INC. 625 TAMKO ROOFING PRODUCTS INC. 628<br />

4301 N.W. 35th Avenue 707 220 W. 4th Street, P.O. Box 1404 663<br />

Miami, FL 33142-4382 Joplin, MO 64802 711<br />

305/633-6333 or 888/24-somay 417/624-6644<br />

FAX: 305/638-5524 FAX: 417/624-8935<br />

E-mail: paint@somay.com<br />

Web: www.somay.com<br />

E-mail: info@tamko.com<br />

Web: www.tamko.com<br />

SOUTHWESTERN PETROLEUM 626 833 TOPCOAT, INC. A SUBSIDIARY OF 630<br />

CORP. (SWEPCO) 662 GAF MATERIALS CORP. 711<br />

534 N. Main St., P.O. Box 961005 707 1361 Alps Road<br />

Ft. Worth, TX 76161-0005 Wayne, NJ 07470<br />

817/332-2336 800/877-9372 973/628-3000 800/766-3411<br />

FAX: 817/877-4047 FAX: 973/628-3451<br />

E-mail: swepcousa.com<br />

Web: www.gaf.com<br />

SPM THERMO-SHIELD INC. 628 TREMCO INC. 632<br />

Rt. 2, Box 208A 710 3735 Green Road 665<br />

Custer, SD 57730 P.O. Box 228069 714<br />

605/673-3201 Beachwood, OH 44122-8069<br />

FAX: 605/673-3200 216/292-5000<br />

E-mail: spm@thermoshield.com FAX: 216/766-5629<br />

Web:<br />

Web: www.tremcoroofing.com<br />

SUNGUARD MARKETING CORP. 628 UNITED COATINGS 636<br />

4432 N.E. Davis 710 P.O. Box 160135 717<br />

Portland, OR 97213 Altamonte Springs, FL 37216-0133<br />

503/235-9206 407/869-5110<br />

FAX: 503/235-9206<br />

FAX:<br />

E-mail:<br />

E-mail:<br />

Web:<br />

Web:<br />

590


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME ALCM ALCM ALCM ALCM ALCM ALCM<br />

2. PRODUCT NAME FIBRATED RUBBERIZED ROOF NO FIBER ASPHALT COLD-PROCESS<br />

LIQUID DAMP SURFACE EMULSION ROOF PRIMER ADHESIVE<br />

ROOF COATING ROOF COATING FIBERED EMULSION<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

X<br />

Asphalt/Coalt Tar Coating X X X<br />

Asphalt/Coal Tar Cement<br />

Asphalt Emulsion X X<br />

Modified Bitumen Coating or Cement<br />

Elas<strong>to</strong>meric Coating or Cement (specify type)<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated FIBRATED FIBRATED FIBRATED NONFIBRATED NONFIBRATED FIBRATED<br />

Color(s) Available BLACK BLACK BLACK BLACK BLACK BLACK<br />

Solids Content (% by volume) 70 65 46 45 48 64<br />

Weight Per Gallon (lbs.) 7.9 8 8.2 8.6 7.4 8.0<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 24 24 12 12 4 24<br />

Coverage (gals./square) 2–3 2–3 2–3 2–3 0.5–1 1.5–3<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X X X<br />

Composite <strong>Roof</strong>ing X X<br />

Modified Bitumen <strong>Roof</strong>ing X X<br />

Single-Ply <strong>Roof</strong>ing X X<br />

Other <strong>Roof</strong>ing X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

X<br />

Concrete/Wood Decks<br />

X<br />

Metal<br />

X<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing X X X X<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing X X X X<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

X<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

X<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, BRUSH, SPRAY,<br />

SPRAY<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS NA NA NA NA NA NA<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS NA NA NA NA NA NA<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS NA NA NA NA NA NA<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1967 1967 1967 1967 1967 1967<br />

9. SALES INFORMATION CONTACT: R. KAPLAN R. KAPLAN R. KAPLAN R. KAPLAN R. KAPLAN R. KAPLAN<br />

800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030<br />

10. TECHNICAL INFORMATION CONTACT: C. FRATIANNE C. FRATIANNE C. FRATIANNE C. FRATIANNE C. FRATIANNE C. FRATIANNE<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030<br />

592


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

ALCM ALCM ALCM ALCM ALCM ALCM ALCM ALCM ALCM ALCM<br />

PLASTIC WET / DRY FLASHTITE GLAS–MASTIC NEOPRENE RUBBERIZED 2.0# 2.0# 3.0# MBA<br />

CEMENT CEMENT RUBBER ROOF CEMENT ALUMINUM ALUMINUM ALUMINUM ADHSIVE<br />

CEMENT FIBERED NON-FI BERED FIBERED BRUSH<br />

X X X X X<br />

X X X<br />

CEMENT<br />

X<br />

FIBRATED FIBRATED FIBRATED FIBRATED FIBRATED FIBRATED FIBRATED NONFIBRATED FIBRATED FIBRATED<br />

BLACK BLACK BLACK BLACK BLACK BLACK ALUMINUM ALUMINUM ALUMINUM BLACK<br />

70 70 70 68 66 66 61 44 60 68<br />

9.5 9.5 9.5 9.3 9.1 9.3 8.8 7.9 9.0 8.60<br />

24 24 24 24 24 24 24 24 24 24<br />

4–8 4–8 4–8 4–8 4–8 4–8 1.5–3 0.5–1 1.5–3 2-3<br />

X X X<br />

X X X<br />

X X X<br />

X X X X X X<br />

X<br />

X X X X X X<br />

X X X X X X<br />

X<br />

X X X X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

TROWEL TROWEL, TROWEL TROWEL TROWEL TROWEL BRUSH, BRUSH, BRUSH, BRUSH,<br />

CAULK SPRAY SPRAY SPRAY SPRAY<br />

NA NA NA NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA NA NA NA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1967 1967 1967 1991 1994 1991 1967 1967 1996<br />

R. KAPLAN R. KAPLAN R. KAPLAN R. KAPLAN R. KAPLAN R. KAPLAN R. KAPLAN R. KAPLAN R. KAPLAN R. KAPLAN<br />

800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030<br />

C. FRATIANNE C. FRATIANNE C. FRATIANNE C. FRATIANNE C. FRATIANNE C. FRATIANNE C. FRATIANNE C. FRATIANNE C. FRATIANNE C. FRATIANNE<br />

800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030 800/556–8030<br />

593


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME ALCM ALCM ALCM ALCO–NVC, ALCO-NVC, ALCO-NVC,<br />

INC. INC. INC.<br />

2. PRODUCT NAME MBA ELASTICOTE BUTYL #216 AF #269T AF SBS #269 AF SBS<br />

ADHESIVE LASTIC FLASHING TROWEL PLUS ADHESIVE<br />

TROWEL CEMENT GRADE<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating<br />

X<br />

Asphalt/Coal Tar Cement X X<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement X X X X<br />

Elas<strong>to</strong>meric Coating or Cement (specify type)<br />

COATING<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated FIBRATED NONFIBRATED FIBRATED FIBRATED FIBRATED NONFIBRATED<br />

Color(s) Available BLACK WHITE BLACK BLACK BLACK BLACK<br />

Solids Content (% by volume) A72 58 71 68 ±2 68<br />

Weight Per Gallon (lbs.) 9.0 8.8 8.6 9.5 9 8<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 24 4 8 48–72 30–40<br />

Coverage (gals./square) 4 2.5 - 3.0 3 - 5 8 8 1.5<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X X<br />

Composite <strong>Roof</strong>ing X X<br />

Modified Bitumen <strong>Roof</strong>ing X X X X X<br />

Single-Ply <strong>Roof</strong>ing X X<br />

Other <strong>Roof</strong>ing X X X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X X<br />

Composite <strong>Roof</strong>ing X X<br />

Metal <strong>Roof</strong>ing X X<br />

Other <strong>Roof</strong>ing X X X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing X<br />

Concrete/Wood Decks<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing X X<br />

Composite <strong>Roof</strong>ing X X<br />

Metal <strong>Roof</strong>ing X X<br />

Other <strong>Roof</strong>ing X X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

X<br />

Cold-Process Modified <strong>Roof</strong>ing X X<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products<br />

X<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing X X<br />

Reroofing/Maintenance X X<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) TROWEL BRUSH, BRUSH TROWEL TROWEL BRUSH, SPRAY,<br />

SPRAY<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS NA NA NA<br />

SQUEEGEE<br />

See Built-Up <strong>Roof</strong>ing Section If Checked X X<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS NA NA NA<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS NA NA NA<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1996 1985 1990 1984 1986 1986<br />

9. SALES INFORMATION CONTACT: R. KAPLAN R. KAPLAN R. KAPLAN SALES SALES SALES<br />

800/556–8030 800/556–8030 800/556–8030 800/323–0029 800/323–0029 800/323–0029<br />

10. TECHNICAL INFORMATION CONTACT: C. FRATIANNE C. FRATIANNE C. FRATIANNE TECH. DEPT. TECH. DEPT. TECH. DEPT.<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/556–8030 800/556–8030 800/556–8030<br />

594


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

ALCO-NVC, ALCO-NVC, ALCO-NVC, ALCO-NVC, AMERICAN AMERICAN AMERICAN AMERICAN AMERICAN AMERICAN<br />

INC. INC. INC. INC. TAR TAR TAR TAR TAR TAR<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

#214 AF #215 AF #207 #270 AF # 1818 # 1825 # 1826 #1840 #1850 #1857<br />

ALUMAGARD NON ALUMAGARD ASPHALT ROOF CAP (A100) (A110) (A470) (A700) (A750) (A690)<br />

FIBRATED COAT FIBRATED COAT ROOF PRIMER MASTIC ATCOCOAT ATCOLAP RAINSTOP ATCOGARD ATCOGARD 2 ATCOSCREEN<br />

X<br />

X X X X X X<br />

X<br />

X<br />

X<br />

NONFIBRATED FIBRATED NONFIBRATED FIBRATED FIBRATED FIBRATED FIBRATED NONFIBRATED FIBRATED FIBRATED<br />

ALUMINUM ALUMINUM BLACK BLACK BLACK BLACK BLACK BLACK BLACK ALUMINUM<br />

40 + 58 +<br />

8.5 8.8 7.2 8 7.8 8 7.2 8.4 8.4 7.5<br />

8–24 8–24 4 6 24–144 24–144 24–144 6–48 6–48 8–24<br />

1 1–1.5 1–1.5 2–2.5 2–6 2–6 2–6 3–12 3–12 0.75–1.5<br />

X X X X X X X X X<br />

X X X<br />

X X X X X X<br />

X X X X X X X X X<br />

X X X X X X<br />

X X X X X X<br />

X X X X X X<br />

X<br />

X<br />

X<br />

X<br />

X X X X X X X X X<br />

X X X X X X X X<br />

X X X X<br />

X X X X<br />

X X X<br />

X X X X<br />

X<br />

BRUSH, SPRAY BRUSH, SPRAY BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, BRUSH, ROLLER,<br />

ROLLER ROLLER SQUEEGEE SQUEEGEE SQUEEGEE SQUEEGEE SQUEEGEE SPRAY SPRAY SPRAY<br />

ADHESIVE, ADHESIVE, NA ADHESIVE, SURFACING, SURFACING,<br />

FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS &<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

ADHESIVE, ADHESIVE, NA ADHESIVE, SURFACING, SURFACING,<br />

FIELDS GLASS & FIELDS GLASS & FIELDS GLASS, FIELDS GLASS, FIELDS GLASS,<br />

POLYESTER POLYESTER SEBS & POLY SEBS & POLY SEBS & POLY<br />

NA NA NA NA NA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1965 1965 1912 1990 1926 1926 1926 1926 1926 1926<br />

SALES SALES SALES SALES T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA<br />

800/323–0029 800/323–0029 800/323–0029 800/323–0029 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098<br />

TECH. DEPT. TECH. DEPT. TECH. DEPT. TECH. DEPT. B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN<br />

800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098<br />

595


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME AMERICAN AMERICAN AMERICAN AMERICAN AMERICAN AMERICAN<br />

TAR TAR TAR TAR TAR TAR<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

2. PRODUCT NAME #1858 # 1859 # 1860 # 1864 # 1866 PREMIUM #1897<br />

SUNSHIELD (A650) SUNSHIELD 2 (A640) FIBERED FLAME BLOC<br />

ATCOSHIELD ATCOSHIELD 2 ALUMINUM COAT<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating X X X X X X<br />

Asphalt/Coal Tar Cement<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement<br />

Elas<strong>to</strong>meric Coating or Cement (specify type)<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED FIBRATED NONFIBRATED FIBRATED FIBRATED FIBRATED<br />

Color(s) Available ALUMINUM ALUMINUM ALUMINUM ALUMINUM ALUMINUM ALUMINUM<br />

Solids Content (% by volume)<br />

Weight Per Gallon (lbs.) 7.8 8.2 7.8 8.2 8.8 8.5<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 8–24 8–24 8–24 8–24 8–24 8–24<br />

Coverage (gals./square) 0.75–1.5 0.75–1.5 0.75–1.5 0.75–1.5 0.75–1.5 0.75–1.5<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X X X X<br />

Composite <strong>Roof</strong>ing X X X X X X<br />

Modified Bitumen <strong>Roof</strong>ing X X X X X X<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing X X X X X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

Concrete/Wood Decks<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing X X X X X X<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing X X X X X X<br />

Other <strong>Roof</strong>ing<br />

X<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) ROLLER, ROLLER, ROLLER, ROLLER, ROLLER, ROLLER,<br />

SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS SURFACING, SURFACING, SURFACING, SURFACING, SURFACING, SURFACING,<br />

FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS &<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS SURFACING, SURFACING, SURFACING, SURFACING, SURFACING, SURFACING,<br />

FIELDS GLASS, FIELDS GLASS, FIELDS GLASS, FIELDS GLASS, FIELDS GLASS, FIELDS GLASS,<br />

SEBS & POLY SEBS & POLY SEBS & POLY SEBS & POLY SEBS & POLY SEBS & POLY<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS NA NA NA NA NA NA<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1926 1926 1926 1926 1926 1926<br />

9. SALES INFORMATION CONTACT: T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA<br />

800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098<br />

10. TECHNICAL INFORMATION CONTACT: B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098<br />

596


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

AMERICAN AMERICAN AMERICAN AMERICAN AMERICAN AMERICAN AMERICAN AMERICAN ANDEK ANDEK<br />

TAR TAR TAR TAR TAR TAR TAR TAR CORP. CORP.<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

#1822 # 1823 #1326 #1931 #1340 #1870 #4200 #5000 BUILDCOAT POLAROOF AC<br />

(A200) ATCOMASTIC ATCOSTOP (A400) (A710) (A610) ATCOWHITE ATCOBRITE<br />

ATCOBOND ATCO PRIME SILVRSEAL<br />

X<br />

X<br />

X X X X<br />

X<br />

ACRYLIC LATEX ACRYLIC LATEX ACRYLIC<br />

NONFIBRATED FIBRATED NONFIBRATED NONFIBRATED NOTFIBRATED FIBRATED NONFIBRATED NONFIBRATED<br />

BLACK BLACK BLACK BLACK BLACK ALUMINUM BLACK ANY<br />

65 67<br />

8.8 8 7.2 7.2 8-4 7.5 11.5 12 8.5 13.5<br />

6 - 12 6–12 4–8 1 - 4 6-48 8-24 8–24 8–24 2-4 30 MINS.<br />

1–3 0.5-1 1.5-3 1.5-3 1.5–2 1.5–2 4 3<br />

X X X X X<br />

X X X X X<br />

X X X X X<br />

X<br />

X X X X X<br />

X X X X<br />

X X X X<br />

X X X<br />

X X X X<br />

X X X<br />

X X X<br />

X X X<br />

X X X X<br />

X X X X<br />

X X X<br />

X X X X<br />

X X X X X X X X<br />

X X X X<br />

X<br />

X<br />

X<br />

X<br />

TROWEL TROWEL ROLLER, ROLLER, BRUSH, ROLLER, ROLLER, ROLLER, BRUSH, BRUSH, SPRAY,<br />

SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY ROLLER ROLLER<br />

NA NA NA NA NA NA SURFACING, SURFACING, NA NA<br />

FIELDS GLASS & FIELDS GLASS &<br />

POLYESTER POLYESTER<br />

NA NA NA NA NA NA SURFACING, SURFACING, NA NA<br />

FIELDS GLASS, FIELDS GLASS,<br />

SEBS & POLY SEBS & POLY<br />

NA NA NA NA NA NA NA NA NO ACRYLIC<br />

USA USA USA USA USA USA USA USA USA USA<br />

1926 1926 1975 1975 1975 1975 1926 1926 1985 1985<br />

T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA H. LISS H. LISS<br />

800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/800–2844 800/800–2844<br />

B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN N. SHEARER N. SHEARER<br />

800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/800–2844 800/800–2844<br />

597


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME ANDEK CONKLIN CONKLIN DEWITT DEWITT DEWITT<br />

CORP. CO., INC. CO., INC. PRODUCTS PRODUCTS PRODUCTS<br />

CO. CO. CO.<br />

2. PRODUCT NAME FLASHBOND RAPID ROOF BENCHMARK PRO FLASH PRO FLASH PRO WET /<br />

PRIMER III FLASHING XTRA FLASHING STICK FLASHING<br />

CEMENT CEMENT CEMENT WET/DRY<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

X<br />

Asphalt/Coalt Tar Coating<br />

Asphalt/Coal Tar Cement X X<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement<br />

X<br />

Elas<strong>to</strong>meric Coating or Cement (specify type) ACRYLIC ACRYLIC<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED NONFIBRATED NONFIBRATED FIBRATED FIBRATED FIBRATED<br />

Color(s) Available BLACK WHITE/TAN/GRAY WHITE/GRAY BLACK BLACK BLACK<br />

Solids Content (% by volume) 60 51.3–54.5 54.0–55.0 72.9 74.4 74.4<br />

Weight Per Gallon (lbs.) 9.0 11.3 10.4–10.8 9.0 9.0 9.0<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 2 2–8 2–8 48–72 48-72 48–72<br />

Coverage (gals./square) 1 3–4 3–4 0.7–1 0.7-1 0.7–1<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X X X X<br />

Composite <strong>Roof</strong>ing X X X X<br />

Modified Bitumen <strong>Roof</strong>ing X X<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing X X X X X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X X X X X<br />

Composite <strong>Roof</strong>ing X X X X X X<br />

Metal <strong>Roof</strong>ing X X X X X X<br />

Other <strong>Roof</strong>ing X X X X X X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

X<br />

Concrete/Wood Decks<br />

X<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing X X X X<br />

Composite <strong>Roof</strong>ing X X X<br />

Metal <strong>Roof</strong>ing X X X<br />

Other <strong>Roof</strong>ing X X X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

X<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

X<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products X X<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing X X<br />

Reroofing/Maintenance X X<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, SPRAY, ROLLER, ROLLER, TROWEL TROWEL TROWEL<br />

ROLLER SPRAY SPRAY<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS NA NA NA<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS NA NA NA<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS NA NA<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1973 1994 1991 1931 1999 1951<br />

9. SALES INFORMATION CONTACT: H. LISS BLDG PROD DIV BLDG PROD DIV D. MCCLELLAN D. MCCLELLAN D. MCCLELLAN<br />

800/800–2844 800/888-8838 800/888-8838 800/962–8599 800/962–8599 800/962–8599<br />

10. TECHNICAL INFORMATION CONTACT: N. SHEARER BLDG PROD DIV BLDG PROD DIV J. MCCLELLAN J. MCCLELLAN J. MCCLELLAN<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/800–2844 800/888-8838 800/888-8838 800/962–8599 800/962–8599 800/962–8599<br />

598


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

DEWITT DEWITT DEWITT DEWITT DEWITT DEWITT DEWITT DEWITT DEWITT DEWITT<br />

PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS<br />

CO. CO. CO. CO. CO. CO. CO. CO. CO. CO.<br />

PRO COAT PRO PRIIMER PRO PRO ASPHALT PRO ASPHALT PROLAP PRO SBS PRO SBS PRO ROOFLOX 300 PRO BRITE 200<br />

FIBER ASPHALT RESATURANT EMULSION EMULSION CEMENT ADHESIVE FLASHING ALUMINUM ALUMINUM<br />

ROOF COATING ASPHALT (FIBRE) (NO FIBRE) CEMENT FIBRE COATING FIBRE COATING<br />

X<br />

X<br />

X X X X<br />

X<br />

X<br />

X<br />

X<br />

FIBRATED FIBRATED FIBRATED FIBRATED NONFIBRATED FIBRATED FIBRATED FIBRATED FIBRATED FIBRATED<br />

BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK ALUMINUM ALUMINUM<br />

70.9 72.1 76.3 48.5 47.4 71.3 69.6 70.9 54.5 54.8<br />

8.2 7.7 8.3 9.0 9.0 81.5 7.9 9.0 9.5 8.7<br />

8 4 8 5 5 48–72 8 8<br />

5 10 2–3 2.5 2.5 5 5 07–1 5 5<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X<br />

X X X X X X X X<br />

X X X<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X X X<br />

X X X X X<br />

SPRAY, BRUSH SPRAY, ROLL SPRAY, BRUSH SPRAY, ROLL SPRAY, ROLL SPRAY, SPRAY, TROWEL SPRAY, SPRAY,<br />

SQUEEGEE SQUEEGEE SQUEEGEE SQUEEGEE SQUEEGEE SQUEEGEE SQUEEGEE SQUEEGEE SQUEEGEE<br />

NA NA NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA NA<br />

NA NA NA NA NA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1931 1931 1992 1991 1991 1991 1987 1987 1991 1931<br />

D. MCCLELLAN D. MCCLELLAN D. MCCLELLAN D. MCCLELLAN D. MCCLELLAN D. MCCLELLAN D. MCCLELLAN D. MCCLELLAN D. MCCLELLAN D. MCCLELLAN<br />

800/962–8599 800/962–8599 800/962–8599 800/962–8599 800/962–8599 800/962–8599 800/962–8599 800/962–8599 800/962–8599 800/962–8599<br />

J. MCCLELLAN J. MCCLELLAN J. MCCLELLAN J. MCCLELLAN J. MCCLELLAN J. MCCLELLAN J. MCCLELLAN J. MCCLELLAN J. MCCLELLAN J. MCCLELLAN<br />

800/962–8599 800/962–8599 800/962–8599 800/962–8599 800/962–8599 800/962–8599 800/962–8599 800/962–8599 800/962–8599 800/962–8599<br />

599


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME DEWITT DEWITT ECOLOGY ECOLOGY ECOLOGY ECOLOGY<br />

PRODUCTS PRODUCTS ROOF ROOF ROOF ROOF<br />

CO. CO. SYSTEMS SYSTEMS SYSTEMS SYSTEMS<br />

2. PRODUCT NAME PRO SILVERFIBRE PRO SILVER ERS 301 ESR 300A ERS 300 T ERS 304<br />

SHIELD 300 ALUM SHIELD 200 ALUM<br />

COAT NO FIBRE COAT NO FIBRE<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

X<br />

Asphalt/Coalt Tar Coating X X X X X<br />

Asphalt/Coal Tar Cement<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement<br />

Elas<strong>to</strong>meric Coating or Cement (specify type)<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED NONFIBRATED NONFIBRATED FIBRATED FIBRATED FIBRATED<br />

Color(s) Available ALUMINUM ALUMINUM BLACK BLACK BLACK BLACK<br />

Solids Content (% by volume) 30.5 30.5 68.2 75 78 75<br />

Weight Per Gallon (lbs.) 8.2 8.2 9 9.5 9.8 9.5<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 8 8 4 48 - 72 48 - 72 48 - 72<br />

Coverage (gals./square) 15 15 1 8 8 9<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X<br />

Composite <strong>Roof</strong>ing X X<br />

Modified Bitumen <strong>Roof</strong>ing X X<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X X X X<br />

Composite <strong>Roof</strong>ing X X X X X<br />

Metal <strong>Roof</strong>ing X X X X X<br />

Other <strong>Roof</strong>ing X X X X X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

X<br />

Concrete/Wood Decks<br />

X<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing X X X<br />

Composite <strong>Roof</strong>ing X X X<br />

Metal <strong>Roof</strong>ing X X<br />

Other <strong>Roof</strong>ing X X X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

X<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

X<br />

Reroofing/Maintenance<br />

X<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) SPRAY, TROWEL BRUSH, SPRAY TROWEL TROWEL TROWEL<br />

SQUEEGEE<br />

ROLLER<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS NA NA NA NA NA NA<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS NA NA NA NA NA<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS NA NA NA NA<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1987 1987 1988 1988 1988 1988<br />

9. SALES INFORMATION CONTACT: D. MCCLELLAN D. MCCLELLAN E. NELSON E. NELSON E. NELSON E. NELSON<br />

800/962–8599 800/962–8599<br />

10. TECHNICAL INFORMATION CONTACT: J. MCCLELLAN J. MCCLELLAN B. PFIEFER B. PFIEFER B. PFIEFER B. PFIEFER<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/962–8599 800/962–8599<br />

600


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY<br />

ROOF ROOF ROOF ROOF ROOF ROOF ROOF ROOF ROOF ROOF<br />

SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS<br />

ERS 302 ERS 309 ERS 100 ERS 200 ERS 305 ERS 307A ERS 307T ERS 308 ERS 315 ERS 306<br />

X X X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

FIBRATED FIBRATED BOTH BOTH NONFIBRATED FIBRATED FIBRATED FIBRATED FIBRATED NONFIBRATED<br />

BLACK BLACK BLACK BLACK ALUMINUM BLACK BLACK ALUMINUM BLACK BLACK<br />

60 60 45 45 58 68 68 60 79 60<br />

9.2 9.2 9.0 9.0 9.1 9.1 9.1 9.2 9.9 9.2<br />

48 - 72 48 - 72 24 - 48 24 - 48 24 - 48 96 96 24 - 48 48 - 72 48 - 72<br />

2 - 3 2 - 3<br />

X X X X X X<br />

X X X X X X<br />

X X X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X<br />

X<br />

X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

BRUSH, BRUSH, BRUSH, BRUSH, BRUSH, BRUSH, BRUSH, BRUSH, TROWEL TROWEL<br />

SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY<br />

NA NA NA NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA NA<br />

ERS 302 PLUS ERS 309 PLUS NA NA NA NA NA NA NA NA<br />

2-3 PLIES 2-3 PLIES<br />

ERS ROOFING ERS ROOFING<br />

USA USA USA USA USA USA USA USA USA USA<br />

1988 1988 1988 1988 1988 1988 1988 1988 1988 1988<br />

E. NELSON E. NELSON E. NELSON E. NELSON E. NELSON E. NELSON E. NELSON E. NELSON E. NELSON E. NELSON<br />

B. PFIEFER B. PFIEFER B. PFIEFER B. PFIEFER B. PFIEFER B. PFIEFER B. PFIEFER B. PFIEFER B. PFIEFER B. PFIEFER<br />

601


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS<br />

CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC<br />

2. PRODUCT NAME F100 C100 M100 F150 F110 F400<br />

POWRCOAT ROOF COAT RUBR COAT POWERSEAL POWRLAP POWRPRIME<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

X<br />

Asphalt/Coalt Tar Coating X X X X<br />

Asphalt/Coal Tar Cement<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement X<br />

Elas<strong>to</strong>meric Coating or Cement (specify type)<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated FIBRATED FIBRATED FIBRATED FIBRATED FIBRATED NONFIBRATED<br />

Color(s) Available BLACK BLACK BLACK BLACK BLACK BLACK<br />

Solids Content (% by volume)<br />

Weight Per Gallon (lbs.) 7.8 7.3 7.6 7.8 8.0 7.0<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 24–144 24–144 24–144 24–144 24–144 4–8<br />

Coverage (gals./square) 2–6 2–6 2–6 2–6 2–6 0.5–1<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X X X<br />

Composite <strong>Roof</strong>ing<br />

Modified Bitumen <strong>Roof</strong>ing<br />

X<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing X X X X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X X X X<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing X X X X X<br />

Other <strong>Roof</strong>ing X X X X X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

X<br />

Concrete/Wood Decks<br />

X<br />

Metal<br />

X<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing X X X X<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing X X X X<br />

Other <strong>Roof</strong>ing X X X X<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing X X X X X<br />

Cold-Process Modified <strong>Roof</strong>ing X X X X X<br />

Roll <strong>Roof</strong>ing (Coated Sheets) X X X X X<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, SPRAY BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, ROLLER,<br />

SQUEEGEE SQUEEGEE SQUEEGEE SQUEEGEE SPRAY SPRAY<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS ADHESIVE, ADHESIVE, ADHESIVE, ADHESIVE, ADHESIVE, NA<br />

FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS &<br />

POLYESTER POLYESTER POLYESTER POLYESTER POLYESTER<br />

See Built-Up <strong>Roof</strong>ing Section If Checked X X X X<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS ADHESIVE, ADHESIVE, ADHESIVE, ADHESIVE, ADHESIVE, NA<br />

FIELDS GLASS, FIELDS GLASS , FIELDS GLASS , FIELDS GLASS , FIELDS GLASS ,<br />

SEBS & POLY SEBS & POLY SEBS & POLY SEBS & POLY SEBS & POLY<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS NA NA NA NA NA NA<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1975 1975 1994 1975 1975 1975<br />

9. SALES INFORMATION CONTACT: T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA<br />

800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098<br />

10. TECHNICAL INFORMATION CONTACT: B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098<br />

602


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS<br />

CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC<br />

F540, 500 F630, F640, F650 F600 F670 M860 M850 F700 M700 F750 M800<br />

ALUMINUM FIBERED FLAMEBLOC MOBLSHIELD POLRBRITE POLRSHIELD POWRGARD RUBRGARD POWRGARD 2 RUBRSTAR<br />

COATING ALUM COAT<br />

X X X X<br />

ACRYLIC LATEX<br />

ACRYLIC LATEX<br />

X X X X<br />

X<br />

NONFIBRATED FIBRATED FIBRATED FIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED FIBRATED NONFIBRATED<br />

ALUMINUM ALUMINUM ALUMINUM ALUMINUM WHITE WHITE BLACK BLACK BLACK GRAY<br />

7.5-8.0 7.5-8.2 8.0 7.7 12 11.5 8.3 8.4 8.3 9.6<br />

8–24 8–24 8–24 8–24 8–24 8–24 6–48 6–48 6–48 6–18<br />

0.75–1.50 0.75–1.50 0.75–1.50 0.75–1.50 1.50–2.0 1.50–2.0 3–12 3–4 3–12 2–4<br />

X X X X X X X X X X<br />

X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X X X X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

ROLLER, ROLLER, ROLLER, ROLLER, ROLLER, ROLLER, BRUSH, BRUSH, BRUSH, BRUSH,<br />

SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY<br />

SURFACING, SURFACING, SURFACING, SURFACING, SURFACING, SURFACING, SURFACING, ADHESIVE, SURFACING, SURFACING,<br />

FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS & FIELDS GLASS &<br />

POLYESER POLYESER POLYESER POLYESER POLYESER POLYESER POLYESER POLYESTER POLYESER POLYESER<br />

X X X X X X X<br />

SURFACING, SURFACING, SURFACING, SURFACING, SURFACING, SURFACING, SURFACING, ADHESIVE, SURFACING, SURFACING,<br />

FIELDS GLASS FIELDS GLASS FIELDS GLASS FIELDS GLASS FIELDS GLASS FIELDS GLASS FIELDS GLASS FIELDS GLASS, FIELDS GLASS FIELDS GLASS<br />

SEBS & POLY SEBS & POLY SEBS & POLY SEBS & POLY SEBS & POLY SEBS & POLY SEBS & POLY SEBS & POLY SEBS & POLY SEBS & POLY<br />

NA NA NA NA NA NA NA NA NA NA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1975 1975 1975 1975 1975 1975 1975 1975 1975 1975<br />

T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA<br />

800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098<br />

B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN<br />

800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098<br />

603


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS<br />

CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC<br />

2. PRODUCT NAME F880 F200 C200 C250 F300 M300<br />

SUNGARD POWRBOND ROOFBOND ROOFFLASH POWRMASTIC RUBRMASTIC<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating<br />

Asphalt/Coal Tar Cement X X X X<br />

Asphalt Emulsion<br />

X<br />

Modified Bitumen Coating or Cement<br />

X<br />

Elas<strong>to</strong>meric Coating or Cement (specify type)<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED FIBRATED FIBRATED FIBRATED FIBRATED FIBRATED<br />

Color(s) Available ALUMINUM BLACK BLACK BLACK BLACK BLACK<br />

Solids Content (% by volume)<br />

Weight Per Gallon (lbs.) 8.8 8.8 8.1 8.2 8.2 8.3<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 6–48 6–12 6–12 6–12 6–12 6–12<br />

Coverage (gals./square) 2–3<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing<br />

X<br />

Composite <strong>Roof</strong>ing<br />

X<br />

Modified Bitumen <strong>Roof</strong>ing<br />

X<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X X X X<br />

Composite <strong>Roof</strong>ing X X X X X<br />

Metal <strong>Roof</strong>ing X X X X X<br />

Other <strong>Roof</strong>ing X X X X X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

Concrete/Wood Decks<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing X X X X X<br />

Composite <strong>Roof</strong>ing X X X X X<br />

Metal <strong>Roof</strong>ing X X X X X<br />

Other <strong>Roof</strong>ing X X X X X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

X<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

X<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, TROWEL TROWEL TROWEL TROWEL, CAULK TROWEL,<br />

SPRAY<br />

CAULK<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS SURFACING, NA NA NA NA NA<br />

FIELDS GLASS &<br />

POLYESER<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS SURFACING, NA NA NA NA NA<br />

FIELDS GLASS<br />

SEBS & POLY<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS NA NA NA NA NA NA<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1975 1975 1975 1975 1975 1975<br />

9. SALES INFORMATION CONTACT: T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA<br />

800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098<br />

10. TECHNICAL INFORMATION CONTACT: B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098<br />

604


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS GAF<br />

CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC CO., LLC MATERIALS<br />

CORP.<br />

C240 M620 M200 C300 M400 F460 M150 M600 M630 GAF PREMIUM<br />

TILEBOND SILVERMASTIC RUBRBOND ROOF MASTIC RUBRPRIME WATERSTOP RUBRSEAL FIREBLOC SILVERSHIELD 3 FIBERED ALUM<br />

ROOF COATING<br />

X X<br />

X<br />

X<br />

X X X<br />

ALKYD RESIN<br />

X<br />

X<br />

FIBRATED FIBRATED FIBRATED FIBRATED NONFIBRATED NONFIBRATED FIBRATED FIBRATED FIBRATED FIBRATED<br />

BLACK ALUMINUM BLACK BLACK BLACK BLACK BLACK ALUMINUM ALUMINUM ALUMINUM<br />

52–56<br />

8.1 9.3 8.3 8 7 7.2 7.6 8 8.1 8.1–8.5<br />

6–12 6–12 6–12 6–12 4–8 4–8 24–144 8–24 8–24 8<br />

.75–1.5 .75–1.5 1.5–2.0<br />

X X X X<br />

X X X<br />

X X X X<br />

X X X X<br />

X X X X X<br />

X X X X<br />

X X X X X<br />

X X X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X X<br />

X X X<br />

X X X<br />

X<br />

X<br />

X<br />

TROWEL TROWEL TROWEL TROWEL ROLLER, ROLLER, BRUSH, SPRAY, ROLLER, ROLLER, BRUSH, ROLLER,<br />

SPRAY SPARY SQUEEGEE SPRAY SPRAY SPRAY<br />

NA NA NA NA NA NA ADHESIVE, SURFACING, SURFACING, NA<br />

FIELDS GLASS & FIELDS GLASS & FIELDS GLASS &<br />

POLYESTER POLYESTER POLYESTER<br />

NA NA NA NA NA NA ADHESIVE, SURFACING, SURFACING, NA<br />

FIELDS GLASS & FIELDS GLASS & FIELDS GLASS &<br />

POLYESTER POLYESTER POLYESTER<br />

NA NA NA NA NA NA NA NA NA NA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1975 1975 1975 1975 1095 1975 1975 1975 1975<br />

T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA T. VANDERLINDA REGIONAL<br />

800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 SALES<br />

B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN B. SHEIN TECH SERVICE<br />

800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/627–4098 800/766-3411<br />

605


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME GAF GAF GAF GAF GAF GAF<br />

MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS<br />

CORP. CORP. CORP. CORP. CORP. CORP.<br />

2. PRODUCT NAME GAF ALUMINUM GAF ASPHALT / GAF ALUMINUM GAF RUBERIOD RUBEROID<br />

ROOF PAINT CONCRETE EMULSION WEATHERCOAT MODIFIED BITUMEN MODIFIED BITUMEN<br />

PRIMER EMIULSION ADHESIVE FLASHING CEMENT<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

X<br />

Asphalt/Coalt Tar Coating<br />

X<br />

Asphalt/Coal Tar Cement<br />

Asphalt Emulsion X X<br />

Modified Bitumen Coating or Cement X X<br />

Elas<strong>to</strong>meric Coating or Cement (specify type)<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED NONFIBRATED NONFIBRATED FIBRATED FIBRATED FIBRATED<br />

Color(s) Available ALUMINUM BLACK ALUMINUM BLACK BLACK BLACK<br />

Solids Content (% by volume) 48–52 61 45 49 58 76–80<br />

Weight Per Gallon (lbs.) 7.8–8.2 7.4 9.0 9.0 8–8.4 10.1–10.5<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 4 4 24 5 24 6<br />

Coverage (gals./square) 0.5 0.5 1–1.5 3–5 1.5 8.0<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X<br />

Composite <strong>Roof</strong>ing X X X<br />

Modified Bitumen <strong>Roof</strong>ing X X<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing<br />

X<br />

Composite <strong>Roof</strong>ing<br />

X<br />

Metal <strong>Roof</strong>ing<br />

X<br />

Other <strong>Roof</strong>ing<br />

X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

X<br />

Concrete/Wood Decks<br />

X<br />

Metal<br />

X<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing<br />

X<br />

Composite <strong>Roof</strong>ing<br />

X<br />

Metal <strong>Roof</strong>ing<br />

X<br />

Other <strong>Roof</strong>ing<br />

X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

X<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

X<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

X<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, BRUSH, BRUSH, SPRAY, BRUSH, SPRAY BRUSH, SPRAY, TWROWEL,<br />

SPRAY SPRAY ROLLER SQUEEGEE NOTCH, SQUEEGEE CAULK<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS NA NA NA NA NA NA<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS NA NA NA NA NA NA<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS NA NA NA NA NA NA<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE<br />

9. SALES INFORMATION CONTACT: REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL<br />

SALES SALES SALES SALES SALES SALES<br />

10. TECHNICAL INFORMATION CONTACT: TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411<br />

606


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

GAF GAF GAF GAF GAF GARDNER / GARDNER / GARDNER / GARDNER / GARDNER /<br />

MATERIALS MATERIALS MATERIALS MATERIALS MATERIALS APOC APOC APOC APOC APOC<br />

CORP. CORP. CORP. CORP. CORP.<br />

GAF JETBLACK TRI PLYH TRI PLY TRI PLY TRI PLY APOC 100 APOC 101 APOC 102 APOC 103 APOC 104<br />

PREMIUM MOD BIT MOD BIT PREMIUM FIBERED ASPHALT CEMENT PLASTIC PLASTIC PLASTIC ASPHALT PLASTIC<br />

FLASHING CEMENT ADHESIVE FLASHING CEMENT ALUMINUM PRIMER CEMENT CEMENT CEMENT PRIMER CEMENT<br />

X<br />

X<br />

X<br />

X X X X X<br />

X<br />

X<br />

FIBRATED NONFIBRATED NONFIBRATED FIBRATED NONFIBRATED FIBRATED FIBERED FIBERED NON-FIBERED FIBERED<br />

BLACK BLACK BLACK ALUMINUM BLACK BLACK<br />

75–78 80 80 80 60 80<br />

8.6–9.0 8.5 8.5 8.5 8.5<br />

6–8 4-8 4-8 4-8 2-8 4-8<br />

8.0 1.5 8 1.5-2 0.5 12 12 12 15 12<br />

X X X X X X<br />

X X X X X X<br />

X<br />

X X X X X X<br />

X X X X X X<br />

X X X X X X<br />

X X X X X X<br />

X X X X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X X X X<br />

X X X X X X<br />

X X X X X X<br />

X X X X X X<br />

X<br />

X<br />

X<br />

TROWEL, BRUSH, SPRAY, BRUSH, BRUSH, ROLLER, BRUSH, TROWEL TROWEL TROWEL BRUSH, TROWEL<br />

CAULK NOTCHED SQUEEGEE TROWEL SPRAY SPRAY SPRAY<br />

NA NA NA NA<br />

NA NA NA NA NA<br />

NA NA NA NA NA<br />

USA USA USA USA USA USA USA USA USA USA<br />

1945 1945 1945 1945 1945<br />

REGIONAL REGIONAL REGIONAL REGIONAL REGIONAL JERRY SMITH JERRY SMITH JERRY SMITH JERRY SMITH JERRY SMITH<br />

SALES SALES SALES SALES SALES<br />

TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE MIKE YAP MIKE YAP MIKE YAP MIKE YAP MIKE YAP<br />

800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411<br />

607


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME GARDNER / GARDNER / GARDNER / GARDNER / GARDNER / GARDNER /<br />

APOC APOC APOC APOC APOC APOC<br />

2. PRODUCT NAME APOC 107 APOC 109 APOC 122 APOC 124 APOC 128 APOC 133<br />

FIBRE WET/DRY FLASHING WET/DRY FLASHING MBA FLASHING<br />

COLD-PLY CEMENT CEMENT CEMENT CEMENT CEMENT<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating<br />

Asphalt/Coal Tar Cement X X X X X<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement<br />

X<br />

Elas<strong>to</strong>meric Coating or Cement (specify type)<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated FIBERED FIBERED FIBERED FIBERED FIBERED FIBERED<br />

Color(s) Available<br />

Solids Content (% by volume) 70 80 80 80 80 80<br />

Weight Per Gallon (lbs.) 8.5 8.5 8.5 8.5 8.5 8.6<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 1/2 4 - 8 4-8 4-8 4-8 4-8<br />

Coverage (gals./square) 12 12 12 12 12<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X X X X<br />

Composite <strong>Roof</strong>ing X X X X X X<br />

Modified Bitumen <strong>Roof</strong>ing<br />

X<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing X X X X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X X X X<br />

Composite <strong>Roof</strong>ing X X X X X<br />

Metal <strong>Roof</strong>ing X X X X X<br />

Other <strong>Roof</strong>ing X X X X X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

Concrete/Wood Decks<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing X X X X<br />

Composite <strong>Roof</strong>ing X X X X<br />

Metal <strong>Roof</strong>ing X X X X<br />

Other <strong>Roof</strong>ing X X X X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

X<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

X<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

X<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, TROWEL TROWEL TROWEL TROWEL TROWEL<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS<br />

SPRAY<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1945 1945 1945 1945 1945 1945<br />

9. SALES INFORMATION CONTACT: JERRY SMITH JERRY SMITH JERRY SMITH JERRY SMITH JERRY SMITH JERRY SMITH<br />

10. TECHNICAL INFORMATION CONTACT: MIKE YAP MIKE YAP MIKE YAP MIKE YAP MIKE YAP MIKE YAP<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

608


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

GARDNER / GARDNER / GARDNER / GARDNER / GARDNER / GARDNER / GARDNER / GARDNER / GARDNER / GARDNER /<br />

APOC APOC APOC APOC APOC APOC APOC APOC APOC APOC<br />

APOC 136 APOC 211 APOC 212 APOC 252 APOC 300 APOC 302 APOC 337 NEOPRENE NEOPRENE NEOPRENE<br />

MBA ALUMINUM ALUMINUM ELASTOMERIC ASPHALT FIBERED ELASTOMERIC FLASHING COATING PITCH PAD<br />

ADHESIVE PAINT COATING WHITE EMULSION EMULSION EMULSION CEMENT SEALANT<br />

X<br />

X<br />

X<br />

X<br />

X X<br />

COATING NEOPRENE NEOPRENE NEOPRENE<br />

NON-FIBERED NON-FIBERED FIBERED NON-FIBERED FIBERED NON-FIBERED FIBRATED NONFIBRATED NONFIBRATED<br />

BLACK BLACK BLACK BLACK<br />

70 60 60 65 45 45 47 75 65 65<br />

8.4 9 9.1 11.5 8.6 8.6 8.5 9 9 9<br />

1/2 4-8 4-8 4-8 4-8 4-8 4-8 4-8 4-8 4-8<br />

100 125 100 50-100 50-100 50-100 50 12 100 2<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X<br />

X X X X X X<br />

X X X X X X<br />

X X X X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X X<br />

X X X<br />

X X X X<br />

X X X X<br />

X<br />

X<br />

X<br />

X X X<br />

X X X<br />

BRUSH, BRUSH, BRUSH, BRUSH BRUSH BRUSH SPRAY,<br />

SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY BRUSH<br />

X<br />

USA USA USA USA USA USA USA USA USA USA<br />

1945 1945 1945 1945 1945 1945 1945 1945 1945 1945<br />

JERRY SMITH JERRY SMITH JERRY SMITH JERRY SMITH JERRY SMITH JERRY SMITH JERRY SMITH JERRY SMITH JERRY SMITH JERRY SMITH<br />

MIKE YAP MIKE YAP MIKE YAP MIKE YAP MIKE YAP MIKE YAP MIKE YAP MIKE YAP MIKE YAP MIKE YAP<br />

609


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

2. PRODUCT NAME VITAPLY GARVITOP GARLA-SHIELD ENERGIZER K WEATHERKING WEATHERKING<br />

PLUS FR<br />

FR TOPCOAT<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating X X X X<br />

Asphalt/Coal Tar Cement<br />

Asphalt Emulsion<br />

X<br />

Modified Bitumen Coating or Cement<br />

X<br />

Elas<strong>to</strong>meric Coating or Cement (specify type)<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED<br />

Color(s) Available BLACK BLACK BLACK BLACK BLACK BLACK<br />

Solids Content (% by volume) 63+ 70+ 51+ 75 75+ 70+<br />

Weight Per Gallon (lbs.) 8.5 8.6 8.6 9.3 9.1 7.9<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 1-2 4 36<br />

Coverage (gals./square) 7-9 7-9 3-5 3 3-5 2-4<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X X X X<br />

Composite <strong>Roof</strong>ing X X X X<br />

Modified Bitumen <strong>Roof</strong>ing<br />

X<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X X<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

Concrete/Wood Decks<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing X X<br />

Composite <strong>Roof</strong>ing<br />

X<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing X X X X X X<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

X<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

X<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

X<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

X<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing X<br />

Reroofing/Maintenance X<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, SPRAY BRUSH, BRUSH, SPRAY<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS<br />

SQUEEGEE SQUEEGEE SQUEEGEE,<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1986 1974 1974 1997 1994 1986<br />

9. SALES INFORMATION CONTACT: R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS<br />

10. TECHNICAL INFORMATION CONTACT: R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

610


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

RUST-GO PRYAMSC GRIP MASTIC ENERGIZER FR WEATHERKING MINERAL EMERGENCY FLASHING GARLA-FLEX GARLA-PRIME<br />

PLUS LAP MASTIC<br />

COATING<br />

X<br />

X<br />

X<br />

X<br />

X<br />

ALKYD ACRYLIC ACRYLIC ACRYLIC<br />

X<br />

NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED FIBRATED FIBRATED NONFIBRATED NONFIBRATED<br />

VARIOUS WHITE BLACK BLACK BLACK WHITE/GRAY BLACK BLACK BLACK BLACK<br />

55+ 50+ 50+ 75+ 70+ 68+ 75+ 70+ 75+ 50+<br />

8.5 8.5 9.2 9.8 7.9 11.6 10 8.3 8.5 7.8<br />

5 4 4 4 4 36 36 36 2<br />

0.25 2 2.5-3.0 3.0 2.4 2 0.5-1.0<br />

X X X X X<br />

X X X X X<br />

X X X<br />

X X X<br />

X X X X X<br />

X X X X X<br />

X X X<br />

X<br />

X<br />

X<br />

X X X<br />

X X X<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

BRUSH, BRUSH, BRUSH, SPRAY, BRUSH, SPRAY, TROWEL TROWEL TROWEL, BRUSH, ROLER,<br />

ROLLER SPRAY SQUEEGEE ROLLER CAULK SPRAY<br />

USA USA USA USA USA USA USA USA USA USA<br />

1968 1984 1989 1994 1995 1999 1975 1990 1976 1974<br />

R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS<br />

R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS<br />

611


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME GARLAND GARLAND GARLAND GARLAND GMX, INC. GMX, INC.<br />

COMPANY COMPANY COMPANY COMPANY<br />

2. PRODUCT NAME GARLA-BRITE SILVER WHITE KNIGHT INSUL-LOCK ULTRA-SHIELD ULTRA-SHIELD<br />

SHIELD INSULATION METAL BUILT-UP<br />

ADHESIVE RUSTPROOFING MASTIC<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating X X X X<br />

Asphalt/Coal Tar Cement<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement<br />

Elas<strong>to</strong>meric Coating or Cement (specify type) URETHANE URETHANE<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED FIBRATED NONFIBRATED FIBRATED<br />

Color(s) Available ALUMINUM ALUMINUM WHITE BLACK<br />

Solids Content (% by volume) 45+ 60+ 75+ 100 48 48<br />

Weight Per Gallon (lbs.) 7.9 8.2 11 8.4 8.2 8.2<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 12 12 48 1-2 24–36 24–36<br />

Coverage (gals./square) 0.5 2 3 1 3–6 2–3<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X<br />

Composite <strong>Roof</strong>ing X X<br />

Modified Bitumen <strong>Roof</strong>ing X X X<br />

Single-Ply <strong>Roof</strong>ing<br />

X<br />

Other <strong>Roof</strong>ing<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing<br />

X<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

X<br />

Other <strong>Roof</strong>ing<br />

X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

Concrete/Wood Decks<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

X<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

X<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

X<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

X<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

X<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance X X X<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH BRUSH, POUR BRUSH, ROLLER BRUSH, ROLLER<br />

ROLLER SPRAY SPRAY<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS WITH POLYMAT<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS WITH POLYMAT<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1974 1976 1999 2000 1989 1989<br />

9. SALES INFORMATION CONTACT: R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS T. CARNEY T. CARNEY<br />

800/321–9336 800/321–9336<br />

10. TECHNICAL INFORMATION CONTACT: R. JUSTUS R. JUSTUS R. JUSTUS R. JUSTUS T. CARNEY T. CARNEY<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/321–9336 800/321–9336<br />

612


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

GMX, INC. GMX, INC. GMX, INC. HENRY HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

ULTRA-SHIELD ULTRA-SHIELD ULTRA-SHIELD HENRY #103 HENRY #104 HENRY #105 LOW HENRY #203 HENRY #403 HENRY #902 HENRY #903<br />

WHITE ROOF NONFIBERED FIBERED LOW VOC ASPHALT VOC WATER COLD APPLIED COLD APPLIED PERMANENT MB HIGH SOLIDS<br />

COATING ALUMINUM ALUMINUM PRIMER PRIMER BASED PRIMER CEMENT CEMENT BOND ADHESIVE ADHESIVE<br />

X X X<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

NONFIBRATED NONFIBRATED NIONFIBRATED FIBRATED FIBRATED NONFIBRATED FIBRATED<br />

BLACK BLACK BLACK BLACK BLACK BLACK BLACK<br />

58 40 52 55 35 33 65 67 68 68<br />

9.2 7.8 8.4 7.5 7.1 8.1 8.4 9.2 9.2 9.9<br />

2–3 1–2 1.0 1.0 1.0<br />

2 1 2 0.3 0.3 0.3 1.5-2 1.5-2 1.5-2 1.5-2<br />

X X X<br />

X<br />

X X X<br />

X<br />

X<br />

X X X X<br />

X X X X<br />

X X X X X<br />

X X X X<br />

X X X<br />

X X X<br />

X X X<br />

X X X<br />

X X X X<br />

X<br />

X X X X<br />

X<br />

X<br />

X X X X<br />

X X X X<br />

X X X X X X X<br />

BRUSH, ROLLER BRUSH, ROLLER BRUSH, ROLLER BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, SPRAY BRUSH, ROLLER, BRUSH, ROLLER,<br />

SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY SQUEEGEE SPRAY, SQUEEGEE SPRAY, SQUEEGEE<br />

X X X X X X X<br />

X X X X X X X<br />

X X X X X<br />

X X X X X<br />

X X X X X X X<br />

USA USA USA USA USA USA USA USA USA USA<br />

1989 1989 1989 1997 1934 1995 1985 1995 1995 1998<br />

T. CARNEY T. CARNEY T. CARNEY WALT MULLEN WALT MULLEN WALT MULLEN WALT MULLEN WALT MULLEN WALT MULLEN WALT MULLEN<br />

800/321–9336 800/321–9336 800/321–9336 800/523-0268 800/523-0268 800/523-0268 800/523-0268 800/523-0268 800/523-0268 800/523-0268<br />

T. CARNEY T. CARNEY T. CARNEY SKIP LEONARD SKIP LEONARD SKIP LEONARD SKIP LEONARD SKIP LEONARD SKIP LEONARD SKIP LEONARD<br />

800/321–9336 800/321–9336 800/321–9336 800/486-1278 800/486-1278 800/486-1278 800/486-1278 800/486-1278 800/486-1278 800/486-1278<br />

X X X X X X X<br />

613


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

2. PRODUCT NAME HENRY #204 HENRY #208 HENRY #209 HENRY #222 HENRY #504 HENRY #505<br />

PLASTIC WET PATCH ELASTOMASTIC ELASTOMASTIC PLASTIC ROOF FLASHMASTER<br />

ROOF CEMENT ROOF CEMENT CEMENT FLASHING CEMENT CEMENT N/A ROOF CEMENT N<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating<br />

Asphalt/Coal Tar Cement X X X<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement X X X<br />

Elas<strong>to</strong>meric Coating or Cement (specify type)<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated FIBRATED FIBRATED FIBRATED FIBRATED FIBRATED FIBRATED<br />

Color(s) Available BLACK BLACK BLACK BLACK BLACK BLACK<br />

Solids Content (% by volume) 66 56 67 73 67 62<br />

Weight Per Gallon (lbs.) 9.9 9.0 10.0 9.5 8.6<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 9.1<br />

Coverage (gals./square) 8.0 8.0 8.0 8.0 8.0 8.0<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Modified Bitumen <strong>Roof</strong>ing<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X X X X X<br />

Composite <strong>Roof</strong>ing X X X X X X<br />

Metal <strong>Roof</strong>ing X X X X X X<br />

Other <strong>Roof</strong>ing X X X X X X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

Concrete/Wood Decks<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing X X X X X X<br />

Composite <strong>Roof</strong>ing X X X X X X<br />

Metal <strong>Roof</strong>ing X X X X X X<br />

Other <strong>Roof</strong>ing X X X X X X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) CAULK, BRUSH, CAULK CAULK, CAULK, CAULK, CAULK,<br />

TROWEL TROWEL TROWEL TROWEL TROWEL TROWEL<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS X X X X X<br />

See Built-Up <strong>Roof</strong>ing Section If Checked X X X X X<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS X X<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

X<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS X X X X X<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1934 1940 1987 1999 1985 1995<br />

9. SALES INFORMATION CONTACT: WALT MULLEN WALT MULLEN WALT MULLEN WALT MULLEN WALT MULLEN WALT MULLEN<br />

800/523-0268 800/523-0268 800/523-0268 800/523-0268 800/523-0268 800/523-0268<br />

10. TECHNICAL INFORMATION CONTACT: SKIP LEONARD SKIP LEONARD SKIP LEONARD SKIP LEONARD SKIP LEONARD SKIP LEONARD<br />

800/486-1278 800/486-1278 800/486-1278 800/486-1278 800/486-1278 800/486-1278<br />

11. SEE APPENDIX IF CHECKED X X X X X X<br />

NA=not applicable<br />

614


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

HENRY HENRY HENRY HENRY HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

HENRY #508 HENRY#905 HENRY #906 H;ENRY #201 HENRY #100 HENRY #107 HENRY #109 HENRY #229 HENRY #307 HENRY #120<br />

WET PATCH FLASHMASTER FLASHMASTER ASPHALT ELASTICMULSION ASPHALT LIQUID ROOF ALUMINUM FIBERED PREMIUM<br />

ROOF CEMENT N/A N/A PLUS ROOF COATING EMULSION EMULSION ASPHALT EMUL ALUM ROOF COAT<br />

X<br />

X X X<br />

X X X X X<br />

X X X X<br />

FIBRATED FIBRATED FIBRATED FIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED FIBRATED NONFIBRATED<br />

BLACK BLACK BLACK BLACK BLACK BLACK BLACK ALUMINUM BLACK ALUMINUM<br />

67 67 67 65 51 48 60 33 48 45<br />

9.5 9.1 9.1 8.4 8.7 8.8 8.7 9.4 8.8 9.1<br />

8.0 8.0 8.0 3.0 3-6 3-6 3-6 1.5 3-6 0.3<br />

X X X X X X X<br />

X X X X X X X<br />

X X X X X X<br />

X X X X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X<br />

X X X<br />

X X X<br />

X X X<br />

X X X X X<br />

X X X X X<br />

X X X X X<br />

X X X X<br />

X X X X<br />

CAULK, CAULK, CAULK, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER,<br />

TROWEL TROWEL TROWEL SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY<br />

X X X X X X X<br />

X X X X X X X<br />

X X X X<br />

X X X X<br />

X X X X X X X<br />

USA USA USA USA USA USA USA USA USA USA<br />

1985 1982 1999 1960 1992 1950 1998 1987


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

2. PRODUCT NAME HENRY #220 HENRY #520 HENRY #521 HENRY #869 HENRY #280 HENRY #287<br />

PREMIUM ALUM FIBERED ALUM 3# FIBRATED ELASTOMERIC WHITE SOLARFLEX<br />

FIBERED COAT ROOF COATING ALUMINUM ALUM ROOF COAT ELASTOMERIC WHITE COATING<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating X X X X<br />

Asphalt/Coal Tar Cement<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement<br />

X<br />

Elas<strong>to</strong>meric Coating or Cement (specify type) X X<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated FIBRATED FIBRATED FIBRATED FIBRATED FIBRATED FIBRATED<br />

Color(s) Available ALUMINUM ALUMINUM ALUMINUM ALUMINUM WHITE/TAN/GRAY WHITE, TAN<br />

Solids Content (% by volume) 42 55 58 42 49 42<br />

Weight Per Gallon (lbs.) 9.6 10.7 11.1 8.5 11.0 10.8<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 2.0 2.0<br />

Coverage (gals./square) 1.5 1.5 1.5 1.5 1.5 2.0<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X X X X<br />

Composite <strong>Roof</strong>ing X X X X X X<br />

Modified Bitumen <strong>Roof</strong>ing X X X X X X<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing X X X X X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

Concrete/Wood Decks<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel)<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS<br />

BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER,<br />

SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

HENRY HENRY HENRY HENRY HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

HENRY #294 HENRY #295 HENRY #112 HENRY #275/276 HENRY #517/518 HENRY #111 HENRY HENRY HENRY PRO GRADE<br />

LOW VOC METAL METAL SEAM METALSHIELD METALSHIELD METALSHEILD INISULBOND RUBBERKOTE RUBBERKOTE RUUBERKOTE #111 ASPHALT<br />

SEAM SEALER SEALER SOLVENT PRIMER ACRYLIC MTL RF CTG METAL ROOF SYS PRIMER BASE COAT TOPCOAT PRIMER<br />

X<br />

X<br />

X<br />

X X X X X X X X<br />

FIBRATED FIBRATED NONFIBRATED FIBRATED FIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED<br />

WHITE WHITE GRAY WHITE / GRAY WHITE / GRAY BLACK CLEAR GRAY WHITE BLACK<br />

9.4 9.4 37.9 44.7 39.4 69 44.7 44.7 59<br />

2.0 2.0 9.7 11.7 9.4 8.8 9.2 11.7 11.7 7.6<br />

2.0 2.0 2.0 10 MIN. 2.1 2.0 4.0<br />

1.0 3.0 3.0 2-2.5 0.2 1.5 1.5 0.5<br />

X X X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

BRUSH, CAULK, BRUSH, CAULK, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER, BRUSH, ROLLER,<br />

TROWEL TROWEL SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY SPRAY<br />

X X X<br />

X X X<br />

X X X<br />

X X X<br />

X X X<br />

USA USA USA USA USA USA USA USA USA USA<br />

1999 1999 1999 1999 1999 1966 1999 1999 1999


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

2. PRODUCT NAME PRO GRADE PRO GRADE PRO GRADE PRO GRADE #331 PRO GRADE #333 PRO GRADE #25<br />

#113 ASPHALT #31 COLD #229 MB A/F COLD PROCESS A/F MOD BIT ALL WEATHER<br />

PRIMER PROCESS ADHESIVE FLASHING CEMENT ADHESIVE ADHESIVE ROOF CEMENT<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

X<br />

Asphalt/Coalt Tar Coating X X<br />

Asphalt/Coal Tar Cement<br />

X<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement X X<br />

Elas<strong>to</strong>meric Coating or Cement (specify type)<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED FIBRATED FIBRATED FIBRATED FIBRATED FIBRATED<br />

Color(s) Available BLACK BLACK BLACK BLACK BLACK BLACK<br />

Solids Content (% by volume) 49 60 68 62 68 67<br />

Weight Per Gallon (lbs.) 7.4 8.0 10.0 8.1 9.9 8.5<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 1.0<br />

Coverage (gals./square) 0.3 2 8 2 1.5 8<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Modified Bitumen <strong>Roof</strong>ing<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X<br />

Composite <strong>Roof</strong>ing X X<br />

Metal <strong>Roof</strong>ing X X<br />

Other <strong>Roof</strong>ing<br />

X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

X<br />

Concrete/Wood Decks<br />

X<br />

Metal<br />

X<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing X X<br />

Composite <strong>Roof</strong>ing X X<br />

Metal <strong>Roof</strong>ing X X<br />

Other <strong>Roof</strong>ing X X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing X X X<br />

Cold-Process Modified <strong>Roof</strong>ing X X X<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products X X X<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing X X X<br />

Reroofing/Maintenance X X X<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, ROLLER, BRUSH, ROLLER, CAULK, BRUSH, ROLLER, BRUSH, ROLLER, CAULK,<br />

SPRAY SPRAY, SQUEEGEE TROWEL SPRAY, SQUEEGEE SPRAY, SQUEEGEE TROWEL<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS X X X X X<br />

See Built-Up <strong>Roof</strong>ing Section If Checked X X X X X<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS X X<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked X X<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS X X X X X<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

HENRY HENRY HENRY HENRY HENRY HENRY HENRY HENRY HENRY KARNAK<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY CORP.<br />

PRO GRADE #26 PRO GRADE #27 PRO GRADE #225 PRO GRADE #832 PRO GRADE #842 PRO GRADE #550 MONSEY GRUNDY GRUNDY #19<br />

PLASTIC ROOF FLASHING A/F ALL WEATHER UNFIBERED A/F FIBERED ELASTOMERIC MBA GOLD ASPHALT BU 68 FIBERED ROOF FLASHING<br />

CEMENT CEMENT ROOF CEMENT ALUM ROOF COAT ALUM ROOF COAT WHITE ROOF COAT ADHESIVE RESATURANT MASTIC II CEMENT<br />

X X X X<br />

X X X X<br />

X<br />

X<br />

FIBRATED FIBRATED FIBRATED NONFIBRATED FIBRATED NONFIBRATED FIBRATED FIBRATED FIBRATED FIBERED<br />

BLACK BLACK BLACK ALUMINUM ALUMINUM WHITE BLACK BLACK BLACK BLACK<br />

70 62 72 37 45 44.7 54 64 64<br />

9.8 8.4 8.2 8.0 7.5 11.7 8.1 7.9 8.1<br />

2.0<br />

8 8 8 0.3 1.5 3.0 1.5 8<br />

X X X X X<br />

X X X X X<br />

X<br />

X<br />

X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

CAULK, CAULK, CAULK, BRUSH, ROLL, BRUSH, BRUSH, ROLL, SPRAY, BRUSH, BRUSH, TROWEL<br />

TROWEL TROWEL TROWEL SPRAY SPRAY SPRAY SQUEEGEE SPRAY SPRAY<br />

X X X<br />

X X X<br />

X X X<br />

X<br />

X<br />

USA USA USA USA USA USA USA USA USA USA<br />


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME KARNAK KARNAK KARNAK KARNAK KARNAK KARNAK<br />

CORP. CORP. CORP. CORP. CORP. CORP.<br />

2. PRODUCT NAME #19 AF #19 ULTRA #66 AF #71 AF #78 AF #81AF<br />

FLASHING RUBERIZED MODIFIED BITUMEN ROOF COATING COLD ADHESIVE MODIFIED BITUMEN<br />

CEMENT FLASHING CEMENT ADHESIVE CEMENT ADHESIVE<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating<br />

X<br />

Asphalt/Coal Tar Cement X X<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement X X<br />

Elas<strong>to</strong>meric Coating or Cement (specify type)<br />

CEMENT<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated FIBERED FIBERED FIBERED FIBERED FIBERED FIBERED<br />

Color(s) Available BLACK BLACK BLACK BLACK BLACK BLACK<br />

Solids Content (% by volume)<br />

Weight Per Gallon (lbs.) 8.65 8.65<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 24–48 24–48<br />

Coverage (gals./square) 8 8 1–2 4 2–4 1–2<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X X<br />

Composite <strong>Roof</strong>ing X X X X<br />

Modified Bitumen <strong>Roof</strong>ing X X X<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X X X X X<br />

Composite <strong>Roof</strong>ing X X X X<br />

Metal <strong>Roof</strong>ing X X<br />

Other <strong>Roof</strong>ing X X X X X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

Concrete/Wood Decks<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing X X X<br />

Composite <strong>Roof</strong>ing X X X<br />

Metal <strong>Roof</strong>ing X X<br />

Other <strong>Roof</strong>ing X X X X X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing X X<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing X X<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

X<br />

Cold-Process Modified <strong>Roof</strong>ing X X<br />

Roll <strong>Roof</strong>ing (Coated Sheets) X X<br />

Shingles, Tiles Other Steep Products X X<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing X X X X X<br />

Reroofing/Maintenance X X X X X X<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) TROWEL TROWEL TROWEL, SPRAY, BRUSH, BRUSH, BRUSH, SPRAY,<br />

BRUSH, SQUEEGEE SPRAY SPRAY TROWEL,SQUEEGEE<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS COLD-PROCESS<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS<br />

SYSTEM + POLY-<br />

MAT + ALUMINUM<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1982 1998 1989 1948 1977 1981<br />

9. SALES INFORMATION CONTACT: SALES DEPT SALES DEPT SALES DEPT SALES DEPT SALES DEPT SALES DEPT<br />

800/526–4236 800/526-4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236<br />

10. TECHNICAL INFORMATION CONTACT: TECH DEPT TECH DEPT TECH DEPT TECH DEPT TECH DEPT TECH DEPT<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/526–4236 800/526-4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236<br />

620


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

KARNAK KARNAK KARNAK KARNAK KARNAK KARNAK KARNAK KARNAK KARNAK KARNAK<br />

CORP. CORP. CORP. CORP. CORP. CORP. CORP. CORP. CORP. CORP.<br />

# 97 # 97AF #100 AF # 107 AF #155 #155 AF #169AF NF #170 AF #220 AF #229 AF AR<br />

FIBERED FIBERED NONFIBERATED VELVET AMPHIBOKOTE AMPHIBIKOTE ALUMINUM TAR CEMENT FIBERED ELASTOMERIC<br />

ALUMINUM ALUMINUM EMULSION ROOF COATING WET / DRY WET / DRY EMULSION<br />

X X X X<br />

X X X<br />

X<br />

X X X X<br />

X<br />

CEMENT/COATING<br />

FIBERED FIBERED NONFIBERED NONFIBERED FIBERED FIBERED NONFIBRATED FIBERED FIBERED FIBERED<br />

ALUMINUM ALUMINUM BLACK BLACK BLACK BLACK ALUMINUM BLACK BLACK BLACK<br />

58 66 65<br />

8.5 9.59 8.6<br />

24 24 4–6 24 24-48 24-48<br />

1–1.5 1–1.5 4 1–2 8 8 1–1.5 4 4 4–15<br />

X X X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X<br />

X X X X X X<br />

X X X X X<br />

X X X X X<br />

X X X X<br />

X X X<br />

X X<br />

X<br />

X<br />

X<br />

X X X<br />

X X X<br />

X X X<br />

X X X<br />

X X X X X X X<br />

X X X X X X<br />

X X X<br />

X<br />

X X X<br />

X X X X X X X X<br />

X X X X X X X X X X<br />

BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, BRUSH, TROWEL TROWEL BRUSH, SPRAY, TROWEL BRUSH, BRUSH, ROLLER<br />

ROLLER ROLLER SPRAY SPRAY ROLLER SPRAY TROWEL, SPRAY<br />

NA NA NA NA COLD PROCESS NA<br />

SYSTEM<br />

NA NA NA NA NA NA<br />

NA NA SURFACING NA COLD PROCESS COLD PROCESS<br />

SYSTEM<br />

SYSTSEM<br />

USA USA USA USA USA USA USA USA USA USA<br />

1948 1984 1954 1947 1952 1952 1947 1958 1954 1973<br />

SALES DEPT SALES DEPT SALES DEPT SALES DEPT SALES DEPT SALES DEPT SALES DEPT SALES DEPT SALES DEPT SALES DEPT<br />

800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236<br />

TECH DEPT TECH DEPT TECH DEPT TECH DEPT TECH DEPT TECH DEPT TECH DEPT TECH DEPT TECH DEPT TECH DEPT<br />

800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236<br />

621


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME KARNAK KARNAK KARNAK KARNAK KARNAK KARNAK<br />

CORP. CORP. CORP. CORP. CORP. CORP.<br />

2. PRODUCT NAME #297 AF AQUA-LUM #298 AF ALUMIN - R #501 #505 AF #108 #98 AF<br />

EMULSION ELASTOMERIC ELASTO-BRITE ELASTO-BRITE ASPHALT FIBERED<br />

ALUMINUM ALUMINUM M PRIMER ALUMINUM<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

X<br />

Asphalt/Coalt Tar Coating X X<br />

Asphalt/Coal Tar Cement<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement X X<br />

Elas<strong>to</strong>meric Coating or Cement (specify type) COATING COATING COATING<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated FIBERED NONFIBERED NONFIBERED NONFIBERED NONFIBERED FIBERED<br />

Color(s) Available ALUMINUM ALUMINUM VARIOUS VARIOUS BLACK ALUMINUM<br />

Solids Content (% by volume) 50<br />

Weight Per Gallon (lbs.) 8.5 12.5<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 24–48 24-48 24–48 48 8 24<br />

Coverage (gals./square) 1–1.5 1.5–2.0 2 2 0.5-0.75 1-1.5<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X X X<br />

Composite <strong>Roof</strong>ing X X X<br />

Modified Bitumen <strong>Roof</strong>ing X X X<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing X X X X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

X<br />

Concrete/Wood Decks<br />

X<br />

Metal<br />

X<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing X X X X<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing X X X X<br />

Other <strong>Roof</strong>ing X X X<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing X X X X X<br />

Reroofing/Maintenance X X X X X<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY,<br />

ROLLER ROLLER ROLLER ROLLER ROLLER ROLLER<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS NA NA<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS NA NA<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS ELASTOMERIC ARCHITECTURAL METAL ROOFING<br />

SYSTEM / METAL COATING MAINTENANCE<br />

ROOFING SYSTEM SYSTEM<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1982 1979 1978 1978 1945 1998<br />

9. SALES INFORMATION CONTACT: SALES DEPT SALES DEPT SALES DEPT SALES DEPT SALES DEPT SALES DEPT<br />

800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236<br />

10. TECHNICAL INFORMATION CONTACT: TECH DEPT TECH DEPT TECH DEPT TECH DEPT TECH DEPT TECH DEPT<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236 800/526–4236<br />

622


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

KARNAK KOKEM METACRYLICS METACRYLICS METACRYLICS METACRYLICS METACRYLICS METACRYLICS METACRYLICS METACRYLICS<br />

CORP. PRODUCTS<br />

INC.<br />

#502 SUNGUARD-R ACRYLIC ARCYLIC ACRYLIC ACRYLIC ACRYLIC ACRYLIC ACRYLIC ACRYLIC<br />

RC-W PRIMER GEL BASE WHITE GRAY STORM CLOUD BEIGE DESERT SAND<br />

ELASTO-KOTE<br />

X ELAS. COATING ADHESIVE ACRYLIC MASTIC COATING COATING COATING COATING COATING<br />

NONFIBERED X NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED<br />

VARIOUS VARIOUS BLACK, CLEAR WHITE GRAY WHITE GRAY STORM CLOUD BEIGE DESERT SAND<br />

70 26 67 65 67 67 67 67 67<br />

12 8.5 12 12 12 12 12 12 12<br />

24 4-24 1–24 24 24–48 24–48 24–48 24–48 24–48 24–48<br />

1 0.33–1.5 9 5–7 1–4 1–4 1–4 1–4 1–4<br />

X X X X X X X X X<br />

X X X X X X X X<br />

X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X X<br />

X X X X X<br />

X X X X X<br />

X X X X X X<br />

X X X X X X<br />

X<br />

X<br />

X<br />

X X X X X<br />

X X X X X<br />

X X X X X<br />

X X X X X<br />

X X X X X X X X<br />

X X X X X X X X<br />

X X X X X X X X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

X<br />

X<br />

X X X X X X X X X<br />

X X X X X X X X X<br />

BRUSH, SPRAY, BRUSH, SPRAY BRUSH, SPRAY BRUSH, TROWEL, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY,<br />

ROLLER ROLLER ROLLER RUBBER GLOVE ROLLER ROLLER ROLLER ROLLER ROLLER ROLLER<br />

X<br />

X<br />

ARCH COAT PRIMER + BASE + PRIMER + BASE + PRIMER + BASE + PRIMER + BASE + PRIMER + BASE + PRIMER + BASE + PRIMER + BASE +<br />

SYSTEM / METAL WHITE + FABRIC WHITE + FABRIC WHITE + FABRIC GRAY + FABRIC STORMCLOUD + BEIGE + FABRIC DESERT SAND +<br />

ROOFING FABRIC FABRIC<br />

USA USA USA USA USA USA USA USA USA USA<br />

1975 1979 1972 1981 1981 1981 1981 1981 1981 1981<br />

SALES DEPT R. KO M. ANTHENIEN M. ANTHENIEN M. ANTHENIEN M. ANTHENIEN M. ANTHENIEN M. ANTHENIEN M. ANTHENIEN M. ANTHENIEN<br />

800/526–4236 503/235–9206 408/280–7733 408/280–7733 408/280–7733 408/280–7733 408/280–7733 408/280–7733 408/280–7733 408/280–7733<br />

TECH DEPT R. KO L. ANTHENIEN L. ANTHENIEN L. ANTHENIEN L. ANTHENIEN L. ANTHENIEN L. ANTHENIEN L. ANTHENIEN L. ANTHENIEN<br />

800/526–4236 503/235–9206 408/280–7733 408/280–7733 408/280–7733 408/280–7733 408/280–7733 408/280–7733 408/280–7733 408/280–7733<br />

623


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME METACRYLICS METACRYLICS METACRYLICS METACRYLICS METACRYLICS METACRYLICS<br />

2. PRODUCT NAME ACRYLIC ACRYLIC ACRYLIC ACRYLIC ACRYLIC ACRYLIC<br />

BRICK RED CUSTOM PRIMER BASE WHITE COLORS<br />

COLORS<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

X<br />

Asphalt/Coalt Tar Coating<br />

Asphalt/Coal Tar Cement<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement<br />

Elas<strong>to</strong>meric Coating or Cement (specify type) COATING COATING COATING COATING COATING<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED<br />

Color(s) Available BRICK RED CUSTOM BLK, WHT, CLR GRAY WHITE ANY COLOR<br />

Solids Content (% by volume) 67 67 25 65 67 67<br />

Weight Per Gallon (lbs.) 12 12 8.5 12.1 12.1 12.1<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 24–48 24–48 4 24 12 12<br />

Coverage (gals./square) 1–4 1–4 1 5 4 4<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X X X X<br />

Composite <strong>Roof</strong>ing X X X X X X<br />

Modified Bitumen <strong>Roof</strong>ing X X X X X X<br />

Single-Ply <strong>Roof</strong>ing X X X X X X<br />

Other <strong>Roof</strong>ing X X X X X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X X X X<br />

Composite <strong>Roof</strong>ing X X X X X<br />

Metal <strong>Roof</strong>ing X X X X X<br />

Other <strong>Roof</strong>ing X X X X X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

Concrete/Wood Decks<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing X X X X X X<br />

Coal Tar Built-Up <strong>Roof</strong>ing X X X X X X<br />

Metal <strong>Roof</strong>ing X X X X X X<br />

Other <strong>Roof</strong>ing X X X X X X<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing X X<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

X<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing X X X X X X<br />

Reroofing/Maintenance X X X X X X<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY,<br />

ROLLER ROLLER ROLLER ROLLER ROLLER ROLLER<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS NA NA NA NA<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS NA NA NA NA<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS PRIMER + BASE + PRIMER + BASE +<br />

BRICK RED + CUSTOM +<br />

FABRIC FABRIC<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1981 1981 1974 1974 1974 1974<br />

9. SALES INFORMATION CONTACT: M. ANTHENIEN M. ANTHENIEN M. ANTHENIEN M. ANTHENIEN M. ANTHENIEN M. ANTHENIEN<br />

408/280–7733 408/280–7733 408/280–7733 408/280–7733 408/280–7733 408/280–7733<br />

10. TECHNICAL INFORMATION CONTACT: L. ANTHENIEN L. ANTHENIEN L. ANTHENIEN L. ANTHENIEN L. ANTHENIEN L. ANTHENIEN<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

408/280–7733 408/280–7733 408/280–7733 408/280–7733 408/280–7733 408/280–7733<br />

624


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

METACRYLICS NEOGARD NEOGARD REPUBLIC REPUBLIC REPUBLIC REPUBLIC REPUBLIC REPUBLIC SOMAY<br />

POWDERED POWDERED POWDERED POWDERED POWDERED POWDERED PRODUCTS<br />

METALS, INC. METALS, NC. METALS, INC. METALS, INC. METALS, INC. METALS, INC.<br />

ACRYLIC PERMA-GARD URETHANE 4 SOLARGARD SOLARGARD PERMAFLEX ALUMAMATION GEOGARD SOLARGARD PRODUCT NO. 842<br />

GEL FR 7419 7441 SERIES HY-BUILD 301 ULTRA ROOF MASTIC<br />

BASE COAT<br />

TOP COAT<br />

MASTIC URETHANE URETHANE ACRYLIC ACRYLIC URETHANE ELASTOMERIC ELASTOMERIC<br />

X<br />

X<br />

NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED FIBRATED FIBRATED FIBRATED NONFIBRATED NONFIBRATED<br />

WHITE, GRAY BLACK WHITE/GRAY/TAN VARIOUS VARIOUS BLACK ALUMINUM GRAY WHITE TERRACOTTA/BEIGE/WHITE<br />

66 90 80 51 51 60 47 65 70 51.5<br />

12.1 11.5 10 11.5 11.1 8.7 8.8 11.0 6.8 11.9<br />

24 24 24 4–6 1 24 24 24 4-6 1<br />

9 0.33 0.67 2–3 2–3 2–6 2–4 3–5 2-4 4<br />

X X X X X X X X X<br />

X X X<br />

X X X X X X X X<br />

X X X X X<br />

X X X X X X X X<br />

X X X X X<br />

X<br />

X<br />

X X X<br />

X X X X<br />

X X X<br />

X<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

YES<br />

X X X X X X X<br />

X X X X X X X X YES<br />

BRUSH, TROWEL SPRAY, ROLLER, SPRAY, ROLLER, BRUSH, SPRAY, BRUSH, SPRAY BRUSH, SPRAY BRUSH, SPRAY BRUSH, SPRAY ROLLER, BRUSH BRUSH, CAULK, ROLLER,<br />

RUBBER GLOVE SQUEEGEE SQUEEGEE ROLLER ROLLER ROLLER ROLLER ROLL, SQUEEGEE SPRAY SPRAY, SQUEEGEE, TROWEL<br />

NA NA NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA NA NA<br />

PRIMER PRIMER NA NA NA NA NA NA<br />

7419, 7441 7419, 7441<br />

USA USA USA USA USA USA USA USA USA USA<br />

1974 1972 1972 1975 1967 1984 1947 1983 1998 1966<br />

M. ANTHENIEN ROOFING DIV. ROOFING DIV. J. MILLIKEN J. MILLIKEN J. MILLIKEN J. MILLIKEN J. MILLIKEN J. MILLIKEN SALES DEPT.<br />

408/280–7733 800/321-6588 800/321-6588 800/551-7081 800/551-7081 800/551-7081 800/551-7081 800/551-7081 800/551-7081 305/633-6333<br />

M. ANTHENIEN ROOFING DIV. ROOFING DIV. M. LISY M. LISY M. LISY M. LISY M. LISY M. LISY TECHNICAL DEPT.<br />

408/280-7733 800/321-6588 800/321-6588 800/551-7081 800/551-7081 800/551-7081 800/551-7081 800/551-7081 800/551-7081 305/633-6333<br />

625


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME SOMAY S0MAY SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN<br />

PRODUCTS PRODUCTS PETROLEUM PETROLEUM PETROLEUM PETROLEUM<br />

CORP. CORP. CORP. CORP.<br />

2. PRODUCT NAME PRODUCT NO. 992 PRIME & SEAL FLEX-SHIELD FLEX-SHIELD GUARDIAN GUARDIAN<br />

PATCH & SEAL PRIMER EM PATCHING EPDM GENERAL PURPOSE<br />

COMPOUND PRIMER PRIMER<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating<br />

Asphalt/Coal Tar Cement<br />

Asphalt Emulsion<br />

X<br />

Modified Bitumen Coating or Cement<br />

Elas<strong>to</strong>meric Coating or Cement (specify type) ELASTOMERIC ACRYLIC RESIN CEMENT ACRYLIC PRIMER ACRYLIC PRIMER<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED FIBRATED NONFIBRATED NONFIBRATED<br />

Color(s) Available WHITE CLEAR, WHITE BLACK BLACK CLEAR CLEAR<br />

Solids Content (% by volume) 69.65 11.02<br />

Weight Per Gallon (lbs.) 9.1 6.9 8.41 8.8 8.43 8.46<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 1 1/2 - 2 4 4 1 2<br />

Coverage (gals./square) 0.25-1.5 11.36 0.25 0.5-1.5<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X<br />

Composite <strong>Roof</strong>ing X X<br />

Modified Bitumen <strong>Roof</strong>ing X X<br />

Single-Ply <strong>Roof</strong>ing<br />

X<br />

Other <strong>Roof</strong>ing X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X X<br />

Composite <strong>Roof</strong>ing X X X<br />

Metal <strong>Roof</strong>ing X X X<br />

Other <strong>Roof</strong>ing X X X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing X X<br />

Concrete/Wood Decks<br />

X<br />

Metal<br />

X<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing X X<br />

Composite <strong>Roof</strong>ing X X<br />

Metal <strong>Roof</strong>ing<br />

X<br />

Other <strong>Roof</strong>ing X X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

X<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

X<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

X<br />

Shingles, Tiles Other Steep Products YES YES<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance YES YES<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, CAULK, ROLLER, BRUSH, CAULK, ROLLER, BRUSH, ROLLER, TROWEL BRUSH, BRUSH, ROLLER,<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS<br />

SPRAY, SQUEEGEE, TROWEL SPRAY, SQUEEGEE, TROWEL SPRAY ROLLER SPRAY<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1966 1986 1970 1994 1997 1997<br />

9. SALES INFORMATION CONTACT: SALES DEPT. SALES DEPT. SALES DEPT. SALES DEPT. SALES DEPT. SALES DEPT.<br />

305/633-6333 305/633-6333 877/585-5588 877/585-5588 877/585-5588 877/585-5588<br />

10. TECHNICAL INFORMATION CONTACT: TECHNICAL DEPT.TECHNICAL DEPT. TECH. DEPT. TECH. DEPT. TECH. DEPT. TECH. DEPT.<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

305/633-6333 305/633-6333 877/585-5588 877/585-5588 877/585-5588 877/585-5588<br />

POLYMASTIC ALU<br />

626


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN<br />

PETROLEUM PETROLEUM PETROLEUM PETROLEUM PETROLEUM PETROLEUM PETROLEUM PETROLEUM PETROLEUM PETROLEUM<br />

CORP. CORP. CORP. CORP. CORP. CORP. CORP. CORP. CORP. CORP.<br />

GUARDIAN HEAVY DUTY HEAVY DUTY HEAVY DUTY H.D. GRAVEL H.D. GRAVEL FLEX-SHIELD FLEX-SHIELD ALUMINUM ADHESIVE<br />

SEAMLESS ROOF COATING PRIMER PATCHING ROOF PRESERV. ROOF PRESERV. ROOF "EM" ROOF ROOF #9<br />

ROOF COATING COMPOUND (ASPHALT) (COAL TAR) COATING COATING COATING<br />

COATING<br />

X<br />

X X X X<br />

X<br />

X<br />

X<br />

X<br />

NONFIBRATED FIBRATED NON-FIBRATED FIBRATED NONFIBRATED NONFIBRATED FIBRATED FIBRATED FIBRATED<br />

BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK SILVER-GREEN BLACK<br />

8.0 8.3 7.2 9.24 8.09 9.75 8.5 8.7 9.69 8.4<br />

1–2 1–2 1–2 2–4 2–4 1–2 1–2<br />

1.0 2.0–5.0 0.5–2.0 10 7 7 1.75–9.0 2.5–6.0 1.0–1.5 1.5–4.0<br />

X X X X X<br />

X X X X<br />

X X X X X<br />

X X X X X<br />

X X X X<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X X X<br />

X<br />

X X X X<br />

X X X X<br />

X<br />

X<br />

X<br />

X<br />

SQUEEGEE, BRUSH, SPRAY, BRUSH, SPRAY, TROWEL, BRUSH, BRUSH, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY,<br />

ROLLER ROLLER ROLLER CAULK SPRAY SPRAY ROLLER ROLLER ROLLER ROLL, SQUEEGEE<br />

X X X X X X X<br />

X X X X X X X<br />

GENERAL, EPDM<br />

PRIMER / H D<br />

POLYMASTIC ALUM.<br />

USA USA USA USA USA USA USA USA USA USA<br />

1997 1933 1933 1933 1980 1980 1970 1994 1933 1933<br />

SALES DEPT. SALES DEPT. SALES DEPT. SALES DEPT. SALES DEPT. SALES DEPT. SALES DEPT. SALES DEPT. SALES DEPT. SALES DEPT.<br />

877/585-5588 800/877-9372 800/877-9372 800/877-9372 800/877-9372 800/877-9372 800/877-9372 800/877-9372 800/877-9372 800/877-9372<br />

TECH. DEPT. TECH. DEPT. TECH. DEPT. TECH. DEPT. TECH. DEPT. TECH. DEPT. TECH. DEPT. TECH. DEPT. TECH. DEPT. TECH. DEPT.<br />

877/585-5588<br />

627


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME SOUTHWESTERN SPM THERMO- SUNGUARD TAMKO TAMKO TAMKO<br />

PETROLEUM SHIELD, INC MARKETING ROOFING ROOFING ROOFING<br />

CORP. CORP. PRODUCTS PRODUCTS PRODUCTS<br />

2. PRODUCT NAME ALUMINUM THERMO SHIELD SUNGUARD TAM-PRO TAM-PRO Q-15 TAM-PRO<br />

ROOF ROOF FIBERED ELASTOMERIC PLASTIC<br />

SHIELD COATING EMULSION COAT FLASHING CEMENT ROOF CEMENT<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating<br />

X<br />

Asphalt/Coal Tar Cement X X<br />

Asphalt Emulsion<br />

X<br />

Modified Bitumen Coating or Cement<br />

Elas<strong>to</strong>meric Coating or Cement (specify type) ACRYLIC ELASTOMERIC<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED FIBRATED FIBRATED FIBRATED<br />

Color(s) Available SILVER SEVERAL X BLACK BLACK BLACK<br />

Solids Content (% by volume) 51-67 70 50 ±5 70 80 ±5<br />

Weight Per Gallon (lbs.) 8.6 8.4 12 8.5 9 9.5<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 1–2 1 4-12 8–24 8 8<br />

Coverage (gals./square) 0.3–0.67 36,559 1 3 8 8<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X X<br />

Composite <strong>Roof</strong>ing X X X<br />

Modified Bitumen <strong>Roof</strong>ing X X X X<br />

Single-Ply <strong>Roof</strong>ing X X X<br />

Other <strong>Roof</strong>ing X X X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X X<br />

Composite <strong>Roof</strong>ing X X X<br />

Metal <strong>Roof</strong>ing X X X<br />

Other <strong>Roof</strong>ing X X X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

Concrete/Wood Decks<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing X X<br />

Composite <strong>Roof</strong>ing X X<br />

Metal <strong>Roof</strong>ing X X<br />

Other <strong>Roof</strong>ing X X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing X X X<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

X<br />

Metal <strong>Roof</strong>ing X X X<br />

Other <strong>Roof</strong>ing X X X<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing X X<br />

Cold-Process Modified <strong>Roof</strong>ing X X<br />

Roll <strong>Roof</strong>ing (Coated Sheets) X X<br />

Shingles, Tiles Other Steep Products X X<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, ROLLER, BRUSH, SPRAY TROWEL TROWEL<br />

ROLLER ROLLER SPRAY, SQUEEGEE ROLLER ROLL, SQUEEGE<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS X<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

X<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS X<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked X X<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1933 1984 1979 1990 1990 1990<br />

9. SALES INFORMATION CONTACT: SALES DEPT. SALES DEPT. REY KO DISTRICT OFF. DISTRICT OFF. DISTRICT OFF.<br />

800/877-9372 605/673-3201 503/235-9206<br />

10. TECHNICAL INFORMATION CONTACT: TECH. DEPT. TECH. DEPT. REY KO TECH SERVICE TECH SERVICE TECH SERVICE<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

605/673-3201 503/235-9206 800/641–4691 800/641–4691 800/641–4691<br />

628


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO<br />

ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING<br />

PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS<br />

TAM-PRO TAM-PRO TAM-PRO WET/ TAM-PRO HEAVY- TAM-PRO TAM-PRO TAM-PRO FIRE TAM-PRO TAM-PRO TAM-PRO<br />

FIBERED COLD APPLIED DRY SURFACE BODY FLASHING FIBERED ALUM NONFIBER RATE (FR) FIBER CPA SBS CPS SBS ASPHALT<br />

ROOF COAT CEMENT PLAS ROOF CEM CEMENT ROOF COAT ALUM COATING ALUM ROOF COAT ADHESIVE FLASH CEMENT PRIMER<br />

X X X X<br />

X X X<br />

X<br />

X<br />

X<br />

FIBRATED FIBRATED FIBRATED FIBRATED FIBRATED NONFIBRATED FIBRATED FIBRATED FIBRATED NONFIBRATED<br />

BLACK BLACK BLACK BLACK SILVER SILVER SILVER BLACK BLACK BLACK<br />

50 60 ±5 80 ±5 75 ±5 40 40 42 58 ±2 75 50 ±5<br />

8.4 8.4 9.5 9.0 8.4 7.6 8.6 8.5 9.0 7.6<br />

8–12 12–24 8 8 2–4 2–4 2–4 1–4 8 1–2<br />

1-4 2 8 8 1.5 1.5 1.5 1.5 8 1<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X X<br />

X X X X X<br />

X X X<br />

X X X X X<br />

X<br />

X<br />

X<br />

X X X X X X<br />

X X X X X X<br />

X X X X X<br />

X X X X X X<br />

X<br />

X<br />

X<br />

X X X X<br />

X X X X<br />

X X X X<br />

X X X X<br />

BRUSH, SPRAY, BRUSH TROWEL, TROWEL BRUSH, BRUSH, SPRAY BRUSH, BRUSH, SPRAY TROWEL, BRUSH, SPRAY,<br />

ROLL, SQUEEGEE CAULK SPRAY ROLLER SPRAY SQUEEGEE CAULK ROLLER<br />

USA USA USA USA USA USA USA USA USA USA<br />

1990 1990 1990 1990 1990 1990 1990 1990 1990 1990<br />

DISTRICT OFF. DISTRICT OFF. DISTRICT OFF. DISTRICT OFF. DISTRICT OFF. DISTRICT OFF. DISTRICT OFF. DISTRICT OFF. DISTRICT OFF. DISTRICT OFF.<br />

TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE TECH SERVICE<br />

800/641–4691 800/641–4691 800/641–4691 800/641–4691 800/641–4691 800/641–4691 800/641–4691 800/641–4691 800/641–4691 800/641–4691<br />

629


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME TOPCOAT, INC. TOPCOAT, INC. TOPCOAT, INC., TOPCOAT, INC. TOPCOAT, INC. TOPCOAT, INC.<br />

SUBSIDIARY OF SUBSIDIARY OF SUBSIDIARY OF SUBSIDIARY OF SUBSIDIARY OF SUBSIDIARY OF<br />

GAF MATERIALS GAF MATERIALS GAF MATERIALS GAF MATERIALS GAF MATERIALS GAF MATERIALS<br />

2. PRODUCT NAME TOP TOPCOAT TOPCOTE LIQUID ONE STEP FASTENER<br />

S 010 CRT MB PLUS FABRIC GRADE<br />

FLASHING GRADE<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating<br />

Asphalt/Coal Tar Cement<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement<br />

Elas<strong>to</strong>meric Coating or Cement (specify type) SYNTHETIC RBR SYNTHETIC RBR SYNTHETIC RBR SYNTHETIC RBR<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED<br />

Color(s) Available UNLIMITED UNLIMITED WHITE WHITE WHITE WHITE<br />

Solids Content (% by volume) 46 71 ±3 65 ± 0.5 71.7 49 69 ±1<br />

Weight Per Gallon (lbs.) 11.4 12.3 ±0.5 11 ± 0.5 10.2<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 1 24 24 24 3 24<br />

Coverage (gals./square) 1 1.75 1.5 0.75<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Modified Bitumen <strong>Roof</strong>ing<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing X X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing X X X X X<br />

Other <strong>Roof</strong>ing<br />

X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

Concrete/Wood Decks<br />

Metal<br />

X<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing X X X<br />

Other <strong>Roof</strong>ing<br />

X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

X<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

X<br />

Metal <strong>Roof</strong>ing X X<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

X<br />

Reroofing/Maintenance X X X<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, SPRAY, SPRAY BRUSH, SPRAY, BRUSH, CAULK, SPRAY CAULK<br />

ROLLER ROLLER TROWEL<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS NA NA NA NA NA NA<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS NA NA NA NA NA NA<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE MEMBRANE<br />

COMPONENT OF COMPONENT OF COMPONENT OF COMPONENT OF COMPONENT OF COMPONENT OF<br />

ROOF SYSTEM ROOF SYSTEM ROOF SYSTEM ROOF SYSTEM ROOF SYSTEM ROOF SYSTEM<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE<br />

9. SALES INFORMATION CONTACT: S. LELLING S. LELLING S. LELLING S. LELLING S. LELLING S. LELLING<br />

800/365-7353 800/365-7353 800/365-7353 800/365-7353 800/365-7353 800/365-7353<br />

10. TECHNICAL INFORMATION CONTACT: S. HOCHT S. HOCHT S. HOCHT S. HOCHT S. HOCHT S. HOCHT<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411<br />

630


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

TOPCOAT, INC. TOPCOAT, INC. TOPCOAT, INC. TOPCOAT, INC. TOPCOAT, INC. TOPCOAT, INC., TOPCOAT, INC., TOPCOAT, INC., TOPCOAT, INC., TOPCOAT, INC.,<br />

SUBSIDIARY OF SUBSIDIARY OF SUBSIDIARY OF SUBSIDIARY OF SUBSIDIARY OF SUBSIDIARY OF SUBSIDIARY OF SUBSIDIARY OF SUBSIDIARY OF SUBSIDIARY OF<br />

GAF MATERIALS GAF MATERIALS GAF MATERIALS GAF MATERIALS GAF MATERIALS GAF MATERIALS GAF MATERIALS GAF MATERIALS GAF MATERIALS GAF MATERIALS<br />

TOPCOAT FLASHING SURFACE WALLCOTE TOPCOAT FLASHING MP-300 MB PRIMING FLEXSEAL SB-900<br />

XR-2000 GRADE SPRAY SEAL SB SYSTEM MEMBRANE GRADE SYSTEM FLASHING<br />

FORMULA<br />

GRADE<br />

X<br />

X<br />

X<br />

SYNTHETIC RBR SYN. RUBBER SYN. RUBBER SYN RUBBER SYN. RUBBER<br />

NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED<br />

WHITE WHITE WHITE UNLIMITED UNLIMITED LT. GRAY, WHITE LT. BLUE WHITE WHITE WHITE<br />

52.5 68 64 60 58 56 42 51 76 78<br />

10.2 12 10.1 11.41 12.5 12 10 11.5 10 10.5<br />

6 24 24 12 2 2 1 1 1 1<br />

0.75 1.5 1 1.5–3.25 1 2 5<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X X X<br />

X X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

SPRAY, SPRAY, BRUSH, SPRAY SPRAY, SPRAY BRUSH, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, BRUSH, CAULK,<br />

ROLLER CAULK ROLLER CAULK ROLLER ROLLER TROWEL TROWEL<br />

NA NA NA NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA NA NA NA<br />

PRIMARY FLASHING MEMBRANE MEMBRANE MEMBRANE FLASHING RUST INHIBITOR ASPHALT PATCH INTERNAL GUTTER SOLVENT BASE<br />

COMPONENT OF COMPONENT OF COMPONENT OF COMPONENT COMPONENT OF COMPONENT OF COMPONENT OF SEALANT COMP. LINER COMP. FLASHING<br />

ROOF SYSTEM ROOF SYSTEM ROOF SYSTEM ROOF SYSTEM ROOF SYSTEM ROOF SYSTEM ROOF SYSTEM ROOF SYSTEM COMPONENT<br />

USA USA USA USA USA USA USA<br />

1979 1979 1980 1983 1993 1984<br />

S. LELLING S. LELLING S. LELLING S. LELLING S. LELLING S. LELLING S. LELLING S. LELLING S. LELLING S. LELLING<br />

800/365-7353 800/365-7353 800/365-7353 800/365-7353 800/365-7353 800/365-7353 800/365-7353 800/365-7353 800/365-7353 800/365-7353<br />

S. HOCHT S. HOCHT S. HOCHT S. HOCHT S. HOCHT S. HOCHT S. HOCHT S. HOCHT S. HOCHT S. HOCHT<br />

800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411 800/766-3411<br />

631


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME TOPCOAT, INC., TREMCO, TREMCO, TREMCO, TREMCO, TREMCO,<br />

SUBSIDIARY OF INC. INC. INC. INC. INC.<br />

GAF MATERIALS<br />

2. PRODUCT NAME SKYLITE ELS POLYROOF TREMFIX FIBERMAT SHEETING<br />

BOND<br />

BLACK<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating<br />

Asphalt/Coal Tar Cement X X X<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement<br />

Elas<strong>to</strong>meric Coating or Cement (specify type) SYN RUBBER ELASTO-CEMENT ELASTO-CEMENT<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED FIBRATED NONFIBRATED FIBRATED FIBRATED NONFIBRATED<br />

Color(s) Available CLEAR BLACK BLACK BLACK BLACK BLACK<br />

Solids Content (% by volume) 40 78 70 73 73 75<br />

Weight Per Gallon (lbs.) 7.5 9.3 8.1 9.1 10.1 8.7<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 0.5 12-24 1 24-48 12-24 24-48<br />

Coverage (gals./square) 2 8 8 8 8 4<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Modified Bitumen <strong>Roof</strong>ing<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X X X<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

X<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

Concrete/Wood Decks<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing X X X X<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

X<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

X<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, TROWEL TROWEL TROWEL TROWEL TROWEL<br />

ROLLER<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS NA BUR MESH BUR MESH BUR MESH BUR MESH NA<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS NA BUR MESH BUR MESH BUR MESH BUR MESH NA<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS FIBERGLASS NA NA NA NA NA<br />

SKYLIGHT<br />

SEALER<br />

7. COUNTRY OF MANUFACTURE USA USA CANADA CANADA USA CANADA<br />

8. YEAR OF FIRST COMMERCIAL USE 1989<br />

9. SALES INFORMATION CONTACT: S. LELLING SALES SALES SALES SALES SALES<br />

800/365-7353 OFFICE OFFICE OFFICE OFFICE OFFICE<br />

10. TECHNICAL INFORMATION CONTACT: S. HOCHT TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/766-3411 DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT<br />

632


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

TREMCO, TREMCO, TREMCO, TREMCO, TREMCO, TREMCO, TREMCO, TREMCO, TREMCO, TREMCO,<br />

INC. INC. INC. INC. INC. INC. INC. INC. INC. INC.<br />

SHEETING TREMPRIME DOUBLE DUTY TREMLASTIC ECOLASTIC TREMLAR TREMAR TREMLITE TREMLITE TREMLITE<br />

BOND W.B. ALUMINUM LRM-H LRM-V METAL PRIMER MASTIC COATING<br />

WHITE L.V. WB<br />

X<br />

X<br />

X<br />

X<br />

X<br />

ELASTO-CEMENT COATIGN ACRYLIC ACRYLIC ACRYLIC<br />

NONFIBRATED NONFIBRATED NONFIBRATED FIBRATED FIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED NONFIBRATED<br />

WHITE BLACK ALUMINUM BLACK BLACK BLACK BLACK GRAY WHITE WHITE<br />

85 48 50 50 87 81 46 69 64<br />

8.7 8.8 7.95 8.4 8.6 8.8 9.1 9.9 10.3 11.5<br />

24-48 0.5 5 4 12-24 6-8 6-8 1 6-8 4<br />

4 0.5 0.5 4 7 4 4 0.2 6 0.75<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

TROWEL BRUSH, SPRAY, ROLLER, ROLLER, ROLLER, SQUEEGEE TROWEL BRUSH, SPRAY, TROWEL BRUSH, SPRAY,<br />

ROLLER BRUSH BRUSH BRUSH, SPRAY ROLLER ROLLER<br />

NA NA NA POLYESTER NA NA NA NA NA NA<br />

MAT CP<br />

NA NA NA POLYESTER NA NA NA NA NA NA<br />

MAT CP<br />

NA NA NA NA NA NA NA NA<br />

CANADA USA CANADA USA CANADA CANADA CANADA USA CANADA USA<br />

1990 1982<br />

SALES SALES SALES SALES SALES SALES SALES SALES SALES SALES<br />

OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE<br />

TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL<br />

DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT<br />

633


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME TREMCO, TREMCO, TREMCO, TREMCO, TREMCO, TREMCO,<br />

INC. INC. INC. INC. INC. INC.<br />

2. PRODUCT NAME TREMLASTIC S ERM- POLYROOF ONE HIGH BUILD TREM PRIME<br />

EMERGENCY SF COAT REFLECTIVE QD LOW<br />

REPAIR MASTIC ALUMINUM ROOF COAT ODER<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

X<br />

Asphalt/Coalt Tar Coating<br />

X<br />

Asphalt/Coal Tar Cement X X<br />

Asphalt Emulsion<br />

X<br />

Modified Bitumen Coating or Cement<br />

Elas<strong>to</strong>meric Coating or Cement (specify type)<br />

ELAST-COATING<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated NONFIBRATED FIBRATED NONFIBRATED FIBRATED NONFIBRATED NONFIBRATED<br />

Color(s) Available BLACK BLACK BLACK ALUMINUM WHITE BLACK<br />

Solids Content (% by volume) 50 80 100 61 70 52<br />

Weight Per Gallon (lbs.) 8.4 9.6 8.6 8.8 6.8 7.8<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 4 12-24 1-2 4-8 4-6 0.5-1<br />

Coverage (gals./square) 4 8 4 2 4 0.25-0.5<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing X X X<br />

Composite <strong>Roof</strong>ing<br />

Modified Bitumen <strong>Roof</strong>ing X X<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

X<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing X X<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing X<br />

Concrete/Wood Decks<br />

Metal<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing X X<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, SPRAY, TROWEL TROWEL ROLLER, BRUSH, ROLLER, BRUSH, ROLLER,<br />

ROLLER SPRAY SPRAY BRUSH<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS POLYESTER BUR MESH BUR MESH NA NA NA<br />

MAT CP<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS POLYESTER BUR MESH BUR MESH NA NA NA<br />

MAT CP<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS NA NA NA NA NA NA<br />

7. COUNTRY OF MANUFACTURE USA USA USA USA USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1995 1999 1997 1996 1998 1998<br />

9. SALES INFORMATION CONTACT: SALES SALES SALES SALES SALES SALES<br />

OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE<br />

10. TECHNICAL INFORMATION CONTACT: TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL TECHNICAL<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT DEPARTMENT<br />

634


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

TREMCO, UNITED UNITED UNITED UNITED UNITED UNITED UNITED UNITED UNITED<br />

INC. COATING COATINGS COATINGS COATINGS COATINGS COATINGS COATINGS COATINGS COATINGS<br />

TREMLITE ROOFMATE UNISEAL ACRYLEX ROOF SHIELD BERM 500 BERM 600 / ELASTRON UNI-TILE ALUMISEAL<br />

EPOXY RUST 300 60 UNITED 600 858 SEALER PRIMER<br />

COAT LOW ODOR<br />

COATING-EPOXY ACRYLIC EPOXY ACRYLIC ACRYLIC ACRYLIC BUTYL EPOXY URETHANE<br />

X<br />

NONFIBRATED<br />

ALUMINUM<br />

TAN<br />

100 52 20 38 60 60 55 60 15 55<br />

10.4 11.8 8.4 10.2 11.5 12 11.5 8.6–9.2<br />

24 2 0.50 0.50 2 4 2 4–6 30 MIN. 1–2<br />

0.5 2–4 0.33 0.40 2–3 3–5 1.5–2 3 0.25–0.5 0.333333333<br />

X<br />

X<br />

X X X<br />

X X X X<br />

X X X X<br />

X X X X X X<br />

X<br />

X X X<br />

X X X<br />

X<br />

X<br />

X<br />

X X X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X X X X<br />

X X X X<br />

X<br />

X<br />

X X X<br />

ROLLER, BRUSH, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY, BRUSH, SPRAY,<br />

SPRAY ROLLER ROLLER ROLLER ROLLER ROLLER ROLLER ROLLER ROLLER ROLLER<br />

NA NA NA NA NA NA NA NA NA NA<br />

NA NA NA NA NA NA NA NA NA NA<br />

NA ROOF MATE BASE NA NA ROOF MATE BASE BERM 500, BERM 500, ELASTRON UNI-TILE ALUMISEAL<br />

COAT, TOP COAT COAT, TOP COAT BERTM 600 & BERM 600 & 858 SEALER<br />

& POLY FABRIC & POLY FABRIC POLY FABRIC POLY FABRIC<br />

USA USA USA USA USA USA USA USA USA USA<br />

2000 1973 1993 1993 1988 1990 1990 1965 1970<br />

SALES C. VANGELDER C. VANGELDER C. VANGELDER C. VANGELDER C. VANGELDER C. VANGELDER C. VANGELDER C. VANGELDER C. VANGELDER<br />

OFFICE 800/541–4383 800/541–4383 800/541–4383 800/541–4383 800/541–4383 800/541–4383 800/541–4383 800/541–4383 800/541–4383<br />

TECHNICAL J. CRACE J. CRACE J. CRACE J. CRACE J. CRACE J. CRACE J. CRACE J. CRACE J. CRACE<br />

DEPARTMENT 800/541–4383 800/541–4383 800/541–4383 800/541–4383 800/541–4383 800/541–4383 800/541–4383 800/541–4383 800/541–4383<br />

635


<strong>Roof</strong> Cements and Adhesives, and Coatings, Part 1: General<br />

Information<br />

1. COMPANY NAME UNITED UNITED<br />

COATINGS COATINGS<br />

2. PRODUCT NAME ADHERE-IT UNIBASE<br />

EPDM PRIMER PRIMER<br />

3.1 PRODUCT DESCRIPTION, GENERAL CATEGORY<br />

Asphalt Primer<br />

Asphalt/Coalt Tar Coating<br />

Asphalt/Coal Tar Cement<br />

Asphalt Emulsion<br />

Modified Bitumen Coating or Cement<br />

Elas<strong>to</strong>meric Coating or Cement (specify type) URETHANE ACRYLIC<br />

3.2 PRODUCT DESCRIPTION, GENERAL FEATURES<br />

Fibrated/Nonfibrated<br />

Color(s) Available<br />

TRANS. GREEN<br />

Solids Content (% by volume) 55<br />

Weight Per Gallon (lbs.) 8.9<br />

Drying Time (hours, 50% R.H. at 70 0 F, <strong>to</strong>uch dry) 1 1<br />

Coverage (gals./square) 0.33–0.5 0.5–1<br />

USES<br />

4A. SURFACING<br />

Built-Up <strong>Roof</strong>ing<br />

X<br />

Composite <strong>Roof</strong>ing<br />

X<br />

Modified Bitumen <strong>Roof</strong>ing<br />

X<br />

Single-Ply <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4B. PATCHING/REPAIRING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4C. PRIMING<br />

Built-Up <strong>Roof</strong>ing<br />

X<br />

Concrete/Wood Decks<br />

X<br />

Metal<br />

X<br />

4D. FLASHING<br />

Built-Up <strong>Roof</strong>ing<br />

Composite <strong>Roof</strong>ing<br />

Metal <strong>Roof</strong>ing<br />

Other <strong>Roof</strong>ing<br />

4E. RESATURATION/RESURFACING<br />

Asphalt Built-Up <strong>Roof</strong>ing<br />

Coal Tar Built-Up <strong>Roof</strong>ing<br />

X<br />

Metal <strong>Roof</strong>ing<br />

X<br />

Other <strong>Roof</strong>ing X X<br />

4F. COLD-PROCESS ADHESIVE/LAP CEMENT<br />

Cold-Process Built-Up <strong>Roof</strong>ing<br />

Cold-Process Modified <strong>Roof</strong>ing<br />

Roll <strong>Roof</strong>ing (Coated Sheets)<br />

Shingles, Tiles Other Steep Products<br />

4G. LIQUID-APPLIED MEMBRANE<br />

New <strong>Roof</strong>ing<br />

Reroofing/Maintenance<br />

5. APPLICATION METHOD(S)<br />

(Brush, Caulk, Roller, Spray, Squeegee, Trowel) BRUSH, SPRAY, BRUSH, SPRAY,<br />

ROLLER ROLLER<br />

ROOF SYSTEM DESCRIPTION (or NA)<br />

6A. ASPHALT BUILT-UP ROOF MEMBRANE COMPONENTS NA NA<br />

See Built-Up <strong>Roof</strong>ing Section If Checked<br />

6B. MODIFIED BITUMEN ROOF MEMBRANE COMPONENTS NA NA<br />

See Modified Bitumen <strong>Roof</strong>ing Section If Checked<br />

6C. LIQUID-APPLIED MEMBRANE ROOF COMPONENTS ADHERE-IT UNIBASE<br />

7. COUNTRY OF MANUFACTURE USA USA<br />

8. YEAR OF FIRST COMMERCIAL USE 1995 1996<br />

9. SALES INFORMATION CONTACT: C. VANGELDER C. VANGELDER<br />

800/541–4383 800/541–4383<br />

10. TECHNICAL INFORMATION CONTACT: J. CRACE J. CRACE<br />

11. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

800/541–4383 800/541–4383<br />

636


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME ALCM ALCM<br />

2. PRODUCT NAME COLD PLASTIC<br />

PROCESS<br />

CEMENT<br />

ADHESIVE<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

X<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

3B.<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

X<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class I as part of any roof system (indicate yes or no)<br />

4D. FM labeling on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

638


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

ALCM ALCM ALCM ALCM ALCM ALCO-NVC,<br />

INC.<br />

WET / DRY FLASHTITE RUBBERIZED MBA MBA #216 AF<br />

CEMENT CEMENT ADHESIVE ADHESIVE FLASHING<br />

BRUSH TROWEL CEMENT<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

639


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME ALCO-NVC, ALCO-NVC,<br />

INC.<br />

INC.<br />

2. PRODUCT NAME #269 AF SBS #269 AF SBS<br />

TROWEL<br />

GRADE<br />

PLUS<br />

ADHESIVE<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

3B.<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

X<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class I as part of any roof system (indicate yes or no)<br />

4D. FM labeling on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

A<br />

640


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

AMERICAN AMERICAN AMERICAN AMERICAN AMERICAN ANDEK<br />

TAR TAR TAR TAR TAR CORP.<br />

COMPANY COMPANY COMPANY COMPANY COMPANY<br />

#1825 #1826 #1822 #1823 #1326 ANDEK<br />

(A110) (A470) (A200) (A300) (A460) BUILDCOATE<br />

ATCO LAP RAINSTOP ATCO BOND ATCO MASTIC ATCO STOP<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

A, B NONE NONE NONE NONE<br />

YES NO NO NO NO<br />

NO NO NO NO NO<br />

NO NO NO NO NO<br />

641


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME DEWITT DEWITT<br />

PRODUCTS<br />

COMPANY<br />

PRODUCTS<br />

COMPANY<br />

2. PRODUCT NAME PRO FLASH PRO WET-<br />

FLASHING<br />

CEMENT<br />

STICK FLASHING<br />

CEMENT<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

X<br />

3B.<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

X<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class I as part of any roof system (indicate yes or no)<br />

4D. FM labeling on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

642


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

DEWITT DEWITT DEWITT ECOLOGY ECOLOGY ECOLOGY<br />

PRODUCTS PRODUCTS PRODUCTS ROOF ROOF ROOF<br />

COMPANY COMPANY COMPANY SYSTEMS SYSTEMS SYSTEMS<br />

PRO FLASH PRO LAP PRO SBS ERS 300-A ERS 300-T ERS-304<br />

XTRA FLASHING CEMENT FLASHING<br />

CEMENT<br />

CEMENT<br />

X<br />

X<br />

X<br />

X<br />

YES<br />

X X X<br />

643


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME FIELDS FIELDS<br />

COMPANY,<br />

LLC<br />

COMPANY,<br />

2. PRODUCT NAME F 110 F 200<br />

POWRLAP<br />

LLC<br />

POWRBOND<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

3B.<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

X<br />

X<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

A, B NONE<br />

4B. UL labeling on packaging (indicate yes or no) YES NO<br />

4C. FM Class I as part of any roof system (indicate yes or no) NO NO<br />

4D. FM labeling on packaging (indicate yes or no) NO NO<br />

5. SEE APPENDIX IF CHECKED<br />

644


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS<br />

COMPANY, COMPANY, COMPANY, COMPANY, COMPANY, COMPANY,<br />

LLC LLC LLC LLC LLC LLC<br />

C 250 F 300 M 300 C 240 M 200 C 300<br />

ROOF FLASH POWRMASTIC RUBRMASTIC TILE BOND RUBR BOND ROOF<br />

MASTIC<br />

X<br />

X<br />

X<br />

X X X<br />

NONE NONE NONE NONE NONE NONE<br />

NO NO NO NO NO NO<br />

NO NO NO NO NO NO<br />

NO NO NO NO NO NO<br />

645


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME FIELDS FIELDS<br />

COMPANY,<br />

LLC<br />

COMPANY,<br />

LLC<br />

2. PRODUCT NAME C 200 F 460<br />

ROOF BOND<br />

WATRSTOP<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

3B.<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

X<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

X<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

NONE<br />

4B. UL labeling on packaging (indicate yes or no) NO NO<br />

4C. FM Class I as part of any roof system (indicate yes or no) NO NO<br />

4D. FM labeling on packaging (indicate yes or no) NO NO<br />

5. SEE APPENDIX IF CHECKED<br />

NONE<br />

646


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

FIELDS FIELDS GAF GAF GAF GAF<br />

COMPANY, COMPANY, MATERIALS MATERIALS MATERIALS MATERIALS<br />

LLC LLC CORP. CORP. CORP. CORP.<br />

M 620 C 100 RUBEROID RUBEROID GAF JETBLACK TRI PLY<br />

SILVRMASTIC ROOF COAT MOD BIT MB FLASHING PREMIUM MOD BIT<br />

ADHESIVE CEMENT FLASHING CEMENT ADHESIVE<br />

X<br />

X<br />

X<br />

X<br />

NONE<br />

NO<br />

NO<br />

NO<br />

A, B<br />

YES<br />

NO<br />

NO<br />

647


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME GAF GARDNER /<br />

MATERIALS<br />

APOC<br />

CORP.<br />

2. PRODUCT NAME TRI PLY APOC 101<br />

MOD BIT<br />

FLASHING CEMENT<br />

PLASTIC<br />

CEMENT<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

3B.<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point X X<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class I as part of any roof system (indicate yes or no)<br />

4D. FM labeling on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

648


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

GARDNER / GARDNER / GARDNER / GARDNER / GARDNER / GARDNER /<br />

APOC APOC APOC APOC APOC APOC<br />

APOC 104 APOC 107 APOC 109 APOC 128 APOC 122 APOC 124<br />

PLASTIC FIBREX WET / DRY FLASHING FLASHING WET / DRY<br />

CEMENT COLD-PLY CEMENT CEMENT CEMENT CEMENT<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

A, B, C<br />

YES<br />

649


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME GARDNER / GARDNER /<br />

APOC<br />

APOC<br />

2. PRODUCT NAME APOC 133 APOC 136<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

MBA FLASHING<br />

CEMENT<br />

MBA<br />

ADHESIVE<br />

3B.<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

X<br />

X<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

A, B, C<br />

4B. UL labeling on packaging (indicate yes or no) YES<br />

4C. FM Class I as part of any roof system (indicate yes or no)<br />

4D. FM labeling on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

650


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

GARDNER / GARDNER / GARLAND GARLAND GARLAND GARLAND<br />

APOC APOC COMPANY COMPANY COMPANY COMPANY<br />

APOC 102 APOC 100 INSUL-LOCK WEATHERKING EMERGENCY FLASHING<br />

PLASTIC PLASTIC INSULATION MASTIC BOND<br />

CEMENT CEMENT ADHESIVE<br />

X<br />

X<br />

X<br />

X<br />

ASTM D5643-94<br />

A<br />

YES NO YES<br />

YES YES NO NO<br />

YES YES NO NO<br />

651


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME GARLAND GARLAND<br />

COMPANY<br />

COMPANY<br />

2. PRODUCT NAME GARLA- WEATHERKING<br />

FLEX<br />

PLUS<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

3B.<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

X<br />

X<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no) YES YES<br />

4C. FM Class I as part of any roof system (indicate yes or no) NO YES<br />

4D. FM labeling on packaging (indicate yes or no) NO YES<br />

5. SEE APPENDIX IF CHECKED<br />

A<br />

652


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

HENRY #203 HENRY #403 HENRY #902 HENRY #903 HENRY #204 HENRY #209<br />

COLD APPLIED COLD APPLY PERMANENT MB HIGH PLASTIC ELASTOMASTIC<br />

ROOF CEMENT CEMENT BOND ADHESIVE SOLIDS ADHES ROOF CEMENT CEMENT<br />

X<br />

X X X X<br />

X<br />

A A A A<br />

X X X X<br />

X X X<br />

X X X<br />

X X X X X X<br />

653


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME HENRY HENRY<br />

COMPANY<br />

COMPANY<br />

2. PRODUCT NAME HENRY #222 HENRY #504<br />

ELASTOMASTIC MB<br />

FLASHING CEMENT<br />

PLASTIC ROOF<br />

CEMENT N/A<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

3B.<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point X X<br />

3F. Other standard (indicate standard)<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class I as part of any roof system (indicate yes or no)<br />

4D. FM labeling on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED X X<br />

654


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

HENRY #505 HENRY #508 HENRY #905 HENRY #906 HENRY #275/276 HENRY #111<br />

FLASHMASTER WET PATCH FLASHMASTER FLASHMASTER METALSHIELD ACRYLIC INSULBOND<br />

ROOF CEMENT N/A N/A PLUS METAL ROOF CTG<br />

X<br />

X<br />

X<br />

X<br />

A<br />

A<br />

X<br />

X<br />

X<br />

X X X X X X<br />

655


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME HENRY HENRY<br />

COMPANY<br />

COMPANY<br />

2. PRODUCT NAME PRO GRADE PRO GRADE<br />

#31 COLD #331 A/F COAT<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

PROCESS AHDES<br />

PROCESS ADHES<br />

3B.<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

X<br />

X<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class I as part of any roof system (indicate yes or no)<br />

4D. FM labeling on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED X X<br />

656


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

PRO GRADE PRO GRADE PRO GRADE PRO GRADE PRO GRADE PRO GRADE<br />

#333 A/F MOD #25 ALL #26 PLASTIC #427 FLASHING #225 A/F ALL #226 A/F PLASTIC<br />

BIT ADHESIVE WEATHER ROOF CEM ROOF CEMENT CEMENT WEATHER ROOF CEM ROOF CEMENT<br />

X<br />

X<br />

X<br />

X<br />

X<br />

A<br />

X X X X X X<br />

657


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME HENRY HENRY<br />

COMPANY<br />

COMPANY<br />

2. PRODUCT NAME PRO GRADE PRO GRADE<br />

#227 A/F FLASHING #229 MB<br />

CEMENT<br />

FLASHING CEMENT<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

3B.<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

X<br />

X<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class I as part of any roof system (indicate yes or no)<br />

4D. FM labeling on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED X X<br />

658


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

HENRY KARNAK KARNAK KARNAK KARNAK KARNAK<br />

COMPANY CORPORATION CORPORATION CORPORATION CORPORATION CORPORATION<br />

MONSEY #19 #19 AF #66 AF #78 AF #155<br />

MBA GOLD FLASHING FLASHING MOD BIT COLD ADHESIVE AMPHIBIKOTE<br />

ADHESIVE CEMENT CEMENT ADHESIVE CEMENT WET / DRY<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

X<br />

YES<br />

YES<br />

A<br />

YES<br />

659


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME KARNAK KARNAK<br />

CORPORATION<br />

CORPORATION<br />

2. PRODUCT NAME #155 AF #81 AF<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

AMPHIBIKOTE<br />

WET / DRY<br />

MOD BIT<br />

ADHESIVE<br />

3B.<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

X<br />

X<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no) YES<br />

4C. FM Class I as part of any roof system (indicate yes or no) YES<br />

4D. FM labeling on packaging (indicate yes or no) YES<br />

5. SEE APPENDIX IF CHECKED<br />

A<br />

660


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

KARNAK METACRYLICS METACRYLICS METACRYLICS METACRYLICS METACRYLICS<br />

CORPORATION<br />

#170 AF BLACK CLEAR ACRYLIC ACRYLIC 65<br />

TAR PRIMER PRIMER WHITE GEL ACRYLIC<br />

CEMENT MASTIC COLORS<br />

YES<br />

A A A A A<br />

YES YES YES YES YES<br />

NO NO NO NO NO<br />

NO NO NO NO NO<br />

661


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME SOUTHWESTERN SOUTHWESTERN<br />

PETROLEUM<br />

CORPORATION<br />

PETROLEUM<br />

CORPORATION<br />

2. PRODUCT NAME HEAVY DUTY FLEX-SHIELD<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

PATCHING<br />

COMPOUND<br />

EM PATCHING<br />

COMPOUND<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

3B.<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

X<br />

X<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

NONE<br />

4B. UL labeling on packaging (indicate yes or no) NO<br />

4C. FM Class I as part of any roof system (indicate yes or no) NO<br />

4D. FM labeling on packaging (indicate yes or no) NO<br />

5. SEE APPENDIX IF CHECKED<br />

NONE<br />

662


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

TAMKO TAMKO TAMKO TAMKO TAMKO TAMKO<br />

ROOFING ROOFING ROOFING ROOFING ROOFING ROOFING<br />

PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS<br />

TAM-PRO TAM-PRO TAM-PRO TAM-PRO Q-15 TAM-PRO TAM-PRO<br />

HEAVY BODIED CPA PREMIUM CPA SBS ELASTOMERIC PLASTIC COLD APPLY<br />

FLASHING CEMENT SBS ADHESIVE FLASHING CEMENT FLASHING CEMENT ROOF CEMENT CEMENT<br />

X X<br />

X X X X<br />

NONE NONE NONE NONE NONE NONE<br />

NO NO NO NO NO NO<br />

NO NO NO NO NO NO<br />

NO NO NO NO NO NO<br />

663


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME TAMKO TREMCO<br />

ROOFING<br />

INC.<br />

PRODUCTS<br />

2. PRODUCT NAME TAM-PRO WET/ ELS<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

DRY PLASTIC<br />

ROOF CEMENT<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

3B.<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

X<br />

X<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

NONE<br />

4B. UL labeling on packaging (indicate yes or no) NO YES<br />

4C. FM Class I as part of any roof system (indicate yes or no) NO YES<br />

4D. FM labeling on packaging (indicate yes or no) NO YES<br />

5. SEE APPENDIX IF CHECKED<br />

664


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

TREMCO, TREMCO, TREMCO, TREMCO, TREMCO,<br />

INC. INC. INC. INC. INC.<br />

TREMFIX FIBERMAT SHEETING SHEETING TREMLITE<br />

BOND - BLACK BOND - WHITE MASTIC<br />

X<br />

YES YES YES YES YES<br />

YES YES YES YES YES<br />

YES YES YES YES YES<br />

665


<strong>Roof</strong> Cements and Adhesives, Part 2: Technical Data<br />

1. COMPANY NAME TREMCO,<br />

INC.<br />

2. PRODUCT NAME ERM<br />

3. COMPLIES WITH:<br />

3A. ASTM D 2822-91 Standard Specification for Asphalt <strong>Roof</strong> Cement<br />

(indicate Type and Class)<br />

TYPE I, CLASS I -- Low softening point asphalt for essentially dry surfaces<br />

EMERGENCY<br />

REPAIR MASTIC<br />

TYPE I, CLASS II -- Los softening point asphalt for damp or wet surfaces<br />

3B.<br />

TYPE II, CLASS I -- High softening point asphalt for essentially dry<br />

surfaces<br />

TYPE II, CLASS II -- High softening point point asphalt for dam or wet<br />

surfaces<br />

ASTM D 3019-94 Standard Specification for Lap Cement Used with<br />

Asphalt Roll <strong>Roof</strong>ing, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Non-Asbes<strong>to</strong>s<br />

Fibered (indicate Type and, if applicable, Grade)<br />

TYPE I, GRADE 1 -- Brush consistency lap cement made with an airblown<br />

asphalt<br />

TYPE I, GRADE 2 -- Brush consistency lap cement made with a vacuumreduced<br />

or steam-refined asphalt<br />

TYPE II -- Heavy brushing or light troweling consistency containing a<br />

quantity of short-fibered asbes<strong>to</strong>s<br />

TYPE III -- Heavy brushing or light troweling consistency containing<br />

mineral and/or other stabilizers but no asbes<strong>to</strong>s<br />

3C. ASTM D 3747-79 Standard Specification for Emulsified Aspalt Adhesive<br />

for Adhering <strong>Roof</strong> Insulation (indicate Type)<br />

Type I -- Above 40º F<br />

Type II -- Above 20º F<br />

3D. ASTM D 4022-94 Standard Specification for Coal Tar <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s Containing (no response or indicate yes)<br />

3E. ASTM D 4586-93 Standard Specification for Asphalt <strong>Roof</strong> Cement,<br />

Asbes<strong>to</strong>s-Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3F. Other standard (indicate standard)<br />

4. FIRE RESISTANCE CLASSIFICATION<br />

4A. UL Classification per ANSI/UL 790 as a part of any roof system (indicate<br />

Class A, B or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no) YES<br />

4C. FM Class I as part of any roof system (indicate yes or no) YES<br />

4D. FM labeling on packaging (indicate yes or no) YES<br />

5. SEE APPENDIX IF CHECKED<br />

666


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME ALCM ALCM<br />

2. PRODUCT NAME FIBRATED RUBBERIZED<br />

LIQUID SAMP SURFACE<br />

ROOF COATING ROOF COATING<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class 1 as part of any roof system (indicate yes or no)<br />

4D. FM labelilng on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

YES<br />

YES<br />

668


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

ALCM ALCM ALCM ALCM ALCM ALCM<br />

ROOF ROOF ASPHALT 2.0# 2.0# 3.0#<br />

EMULSION EMULSION PRIMER ALUMINUM ALUMINUM ALUMINUM<br />

FIBERED NO FIBER FIBER NO FIBER FIBER<br />

YES<br />

YES<br />

YES<br />

YES<br />

YES<br />

YES<br />

13.6 15.2 20.4<br />

669


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME ALCO-NVC, ALCO-NVC,<br />

INC.<br />

INC.<br />

2. PRODUCT NAME #214 AF #215 AF<br />

ALUMAGARD ALUMAGARD<br />

NON-FIBERED FIBERED<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

X<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

X<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9 11 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

A, B A, B<br />

4B. UL labeling on packaging (indicate yes or no) YES YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no)<br />

4D. FM labelilng on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

670


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

ALCO-NVC, ALCO-NVC, AMERICAN AMERICAN AMERICAN AMERICAN<br />

INC. INC. TAR TAR TAR TAR<br />

COMPANY COMPANY COMPANY COMPANY<br />

#207 #270 #1818 #1840 #1850 #1857<br />

ASPHALT ROOF CAP (A100) (A700) (A750) (A690)<br />

ROOF PRIIMER MASTIC ATCOCOAT ATCOGARD ATCOGARD 2 ATCOSCREEN<br />

YES<br />

X<br />

X<br />

X<br />

YES<br />

A A, B A, B A, B NONE<br />

YES YES YES NO<br />

NO NO NO NO<br />

NO NO NO NO<br />

671


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME AMERICAN AMERICAN<br />

TAR<br />

TAR<br />

COMPANY COMPANY<br />

2. PRODUCT NAME #1858 #1859<br />

SUN SHIELD (A650)<br />

ATCOSHIELD<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

X<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

X<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9 11 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

A, B A, B<br />

4B. UL labeling on packaging (indicate yes or no) YES YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) NO NO<br />

4D. FM labelilng on packaging (indicate yes or no) NO NO<br />

5. SEE APPENDIX IF CHECKED<br />

672


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

AMERICAN AMERICAN AMERICAN AMERICAN AMERICAN AMERICAN<br />

TAR TAR TAR TAR TAR TAR<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

#1860 #1864 #1866 #1870 #1897 #1931<br />

SUN SHIELD 2 (A640) PREMIUM (A610) FLAMEBLOC (A400)<br />

ATCOSHIELD 2 FIBERED ALUM SILVR SEAL ATCO PRIME<br />

YES<br />

X<br />

X X X<br />

11 9 9 9<br />

A, B A, B A, B NONE A, B NONE<br />

YES YES YES NO YES NO<br />

NO NO NO NO NO NO<br />

NO NO NO NO NO NO<br />

673


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME AMERICAN AMERICAN<br />

TAR<br />

TAR<br />

COMPANY COMPANY<br />

2. PRODUCT NAME #1340 #4200<br />

(A710)<br />

(A850)<br />

HYDROGARD ATCO WHITE<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

YES<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

NONE<br />

A, B<br />

4B. UL labeling on packaging (indicate yes or no) NO YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) NO NO<br />

4D. FM labelilng on packaging (indicate yes or no) NO NO<br />

5. SEE APPENDIX IF CHECKED<br />

X<br />

674


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

AMERICAN ANDEK ANDEK CONKLIN CONKLIN DEWITT<br />

TAR CORP. CORP. CO., INC. CO., INC. PRODUCTS<br />

COMPANY<br />

COMPANY<br />

#5000 POLAROOF AC FLASHBAND RAPID BENCHMARK PRO<br />

(A860) PRIMER ROOF III PRIMER<br />

ATCO BRITE<br />

YES<br />

YES YES<br />

YES YES<br />

A, B A, B, C A, B, C<br />

YES YES YES<br />

NO NO NO<br />

NO NO NO<br />

675


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME DEWITT DEWITT<br />

PRODUCTS PRODUCTS<br />

COMPANY COMPANY<br />

2. PRODUCT NAME PRO PRO ASPHALT<br />

PRIMER EMULSION<br />

400 FIBRE<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

YES<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

X<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class 1 as part of any roof system (indicate yes or no)<br />

4D. FM labelilng on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

676


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

DEWITT DEWITT DEWITT DEWITT DEWITT ECOLOGY<br />

PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS ROOF<br />

COMPANY COMPANY COMPANY COMPANY COMPANY SYSTEMS<br />

PRO ASPHALT PRO COAT PRO ROOFLOX 300 PRO BIRTE 200 PRO SILVER ERS<br />

EMULSION FIBRE ALUMINUM ALUMINUM SHIELD 200 ALUM 301<br />

NO FIBRE COATING FIBRE COATING COAT - FIBRE COAT NO FIBRE<br />

YES<br />

X<br />

YES<br />

X<br />

X<br />

X<br />

9 9 11<br />

677


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME ECOLOGY ECOLOGY<br />

ROOF<br />

ROOF<br />

SYSTEMS SYSTEMS<br />

2. PRODUCT NAME ERS ERS<br />

302 309<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

A, B, C A, B, C<br />

4B. UL labeling on packaging (indicate yes or no) YES YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) YES YES<br />

4D. FM labelilng on packaging (indicate yes or no) YES YES<br />

5. SEE APPENDIX IF CHECKED<br />

678


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

ECOLOGY ECOLOGY ECOLOGY ECOLOGY ECOLOGY FIELDS<br />

ROOF ROOF ROOF ROOF ROOF COMPANY, LLC<br />

SYSTEMS SYSTEMS SYSTEMS SYSTEMS SYSTEMS<br />

ERS ERS ERS ERS ERS F 100<br />

100 200 307 A 307 T 308 POWRCOAT<br />

X<br />

X<br />

X<br />

9<br />

X<br />

X<br />

X<br />

A, B<br />

YES<br />

NO<br />

NO<br />

679


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME FIELDS FIELDS<br />

COMPANY, LLC COMPANY, LLC<br />

2. PRODUCT NAME M 100 F 150<br />

RUBRCOAT POWR SEAL<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

X<br />

Type II -- High softening point<br />

X<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

A, B A, B<br />

4B. UL labeling on packaging (indicate yes or no) YES YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) NO NO<br />

4D. FM labelilng on packaging (indicate yes or no) NO NO<br />

5. SEE APPENDIX IF CHECKED<br />

680


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS<br />

COMPANY, LLC COMPANY, LLC COMPANY, LLC COMPANY, LLC COMPANY, LLC. COMPANY, LLC.<br />

F 400 F 540, F 550 F 670 M 860 M 850 F 700<br />

POWR PRIME SUNSHIELD MOBL SHIELD POLR BRITE POLR SHIELD POWR GARD<br />

YES<br />

X<br />

X<br />

X<br />

11 9<br />

X<br />

X<br />

NONE A, B A, B A, B A, B A, B<br />

NO YES YES YES YES YES<br />

NO NO NO NO NO NO<br />

NO NO NO NO NO NO<br />

681


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME FIELDS FIELDS<br />

COMPANY, LLC. COMPANY, LLC.<br />

2. PRODUCT NAME F 880 M 150<br />

SUNGARD RUBR SEAL<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

X<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

A, B A, B<br />

4B. UL labeling on packaging (indicate yes or no) YES YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) NO NO<br />

4D. FM labelilng on packaging (indicate yes or no) NO NO<br />

5. SEE APPENDIX IF CHECKED<br />

X<br />

682


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

FIELDS FIELDS FIELDS FIELDS FIELDS FIELDS<br />

COMPANY, LLC. COMPANY, LLC. COMPANY, LLC. COMPANY, COMPANY, LLC. COMPANY, LLC.<br />

LLC<br />

F 630 F 640 F 650 F 600 M 700 F 750<br />

SOLAR SHIELD SOLAR SHIELD SOLAR SHIELD FLAMEBLOC RUBR GARD POWR GARD<br />

3 2 2<br />

X<br />

X<br />

X X X X<br />

9 9 9 9<br />

A, B A, B A, B A, B A, B A, B<br />

YES YES YES YES YES YES<br />

NO NO NO NO NO NO<br />

NO NO NO NO NO NO<br />

683


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME FIELDS FIELDS<br />

COMPANY, LLC. COMPANY, LLC.<br />

2. PRODUCT NAME M 800 M 400<br />

RUBR STAR RUBR PRIME<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

A, B NONE<br />

4B. UL labeling on packaging (indicate yes or no) YES NO<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) NO NO<br />

4D. FM labelilng on packaging (indicate yes or no) NO NO<br />

5. SEE APPENDIX IF CHECKED<br />

X<br />

YES<br />

684


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

FIELDS FIELDS GAF GAF GAF GAF<br />

COMPANY, LLC. COMPANY, LLC. MATERIALS MATERIALS MATERIALS MATERIALS<br />

CORP. CORP. CORP. CORP.<br />

M 600 M 630 FI8ERED GAF ASPHALT TRI PLY FIBERED<br />

SILVR BLOC SILVR SHIELD ALUMINUM ALUMINUM CONCRETE ALUMINUM<br />

3 ROOF COATING ROOF PAINT PRIMER ROOF COATING<br />

YES<br />

X X X X<br />

9 9 9 11 9<br />

X<br />

A, B A, B A A<br />

YES<br />

YES<br />

NO<br />

NO<br />

NO<br />

NO<br />

685


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME GAF GARDNER /<br />

MATERIALS APOC<br />

CORP.<br />

2. PRODUCT NAME TRI PLY APOC 103<br />

ASPHALT ASPHALT<br />

CONCRETE PRIMER PRIMER<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

YES<br />

YES<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class 1 as part of any roof system (indicate yes or no)<br />

4D. FM labelilng on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

686


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

GARDNER / GARDNER / GARDNER / GARDNER / GARDNER / GARDNER /<br />

APOC APOC APOC APOC APOC APOC<br />

APOC 211 APOC 300 APOC 302 APOC 252 APOC 337 APOC<br />

ALUMINUM ASPHALT FIBERED WHITE MODIFIED NEOPRENE<br />

PAINT EMULSION EMULSION ELASTOMERIC EMULSION COATING<br />

X<br />

X<br />

X<br />

X<br />

11<br />

X<br />

YES<br />

A, B, C A, B, C A, B, C A, B, C A, B, C<br />

YES YES YES YES YES<br />

687


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME GARDNER / GARDNER /<br />

APOC<br />

APOC<br />

2. PRODUCT NAME APOC APOC<br />

NEOPRENE NEOPRENE<br />

PITCH PAN SEALANT FLASHING CEMENT<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class 1 as part of any roof system (indicate yes or no)<br />

4D. FM labelilng on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

X<br />

X<br />

688


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND<br />

COMPANY, COMPANY, COMPANY, COMPANY, COMPANY, COMPANY,<br />

INC. INC. INC. INC. INC. INC.<br />

VITA PLY GRAVI TOP GRIP GARLA SHIELD ENERGIZER WEATHER KING<br />

MASTIC K PLUS FR FR TOP COAT<br />

X<br />

X<br />

X<br />

X X X<br />

A A A A A A<br />

NO NO NO NO NO NO<br />

NO NO YES YES YES YES<br />

NO NO NO YES YES YES<br />

689


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME GARLAND GARLAND<br />

COMPANY, COMPANY,<br />

INC<br />

INC.<br />

2. PRODUCT NAME WHITE GARLA PRIME<br />

KNIGHT<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

NONE<br />

NONE<br />

4B. UL labeling on packaging (indicate yes or no) NO NO<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) NO NO<br />

4D. FM labelilng on packaging (indicate yes or no) NO NO<br />

5. SEE APPENDIX IF CHECKED<br />

YES<br />

690


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

GARLAND GARLAND GARLAND GARLAND GARLAND GARLAND<br />

COMPANY, COMPANY, COMPANY, COMPANY, COMPANY, COMPANY,<br />

INC. INC. INC. INC. INC. INC.<br />

GARLA BASE SILVER RUST GO PYRAMIC ENERGIZER MINERAL<br />

SHIELD FR LAP<br />

COATING<br />

X<br />

X<br />

11 9<br />

X<br />

YES<br />

YES<br />

A A A A NONE<br />

NO NO NO NO NO NO<br />

YES YES NO YES YES NO<br />

YES NO NO YES YES NO<br />

691


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME GMX, INC. GMX, INC.<br />

2. PRODUCT NAME ULTRA-SHIELD ULTRA-SHIELD<br />

BUILT-UP<br />

METAL<br />

MASTIC RUSTPROOFING<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point X X<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class 1 as part of any roof system (indicate yes or no)<br />

4D. FM labelilng on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

692


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

GMX, INC. GMX, INC. GMX, INC. HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY<br />

ULTRA-SHIELD ULTRA-SHIELD ULTRA-SHIELD HENRY #104 HENRY #106 HENRY #201<br />

WHITE ROOF FIBERED NON FIBERED ASPHALT LOW VOC WATER FIBERED ROOF<br />

COATING FR ALUMINUM ALUMINUM PRIMER BASED PRIMER COATING<br />

YES<br />

YES<br />

YES<br />

X<br />

X<br />

9 11<br />

X<br />

X<br />

X<br />

X X X<br />

693


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME HENRY HENRY<br />

COMPANY COMPANY<br />

2. PRODUCT NAME HENRY #100 HENRY #107<br />

ELASTOMULSION ASPHALT<br />

EMULSION<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement X X<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

A<br />

A<br />

4B. UL labeling on packaging (indicate yes or no) X X<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) X<br />

4D. FM labelilng on packaging (indicate yes or no) X<br />

5. SEE APPENDIX IF CHECKED X X<br />

694


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

HENRY #109 HENRY #229 HENRY # 307 HENRY #120 HENRY #220 HENRY #520<br />

LIQUID ALUMINUM FIBERED PREMIUM ALUM PREMIUM ALUM FIBERED ALUM<br />

ROOF EMULSION ASPHALT EMUL ROOF COATING FIBERED COATING ROOF COATING<br />

X<br />

X<br />

>9 >11 >11 >11<br />

A A A A A A<br />

X X X X YES YES<br />

X X X X<br />

695


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME HENRY HENRY<br />

COMPANY COMPANY<br />

2. PRODUCT NAME HENRY #521 HENRY #869<br />

3# FIBRATED ELASTOMERIC<br />

ALUMINUM ALUM ROOF CTG<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers X X<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9 18.5<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

A<br />

4B. UL labeling on packaging (indicate yes or no) YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no)<br />

4D. FM labelilng on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

696


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

HENRY #280 HENRY #287 HENRY #275/276 PRO GRADE # 113 PRO GRADE #333 PRO GRADE #41<br />

WHITE SOLARFLEX METALSHIELD ASPHALT A/F MOD FIBERED<br />

ELASTOMEIC WHITE COATING ACRYLIC MTL CTG PRIMER BIT ADHESIVE ROOF COATING<br />

YES<br />

YES<br />

A A A A<br />

YES YES YES<br />

X<br />

X<br />

697


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME HENRY HENRY<br />

COMPANY COMPANY<br />

2. PRODUCT NAME PRO GRADE #441 PRO GRADE #160<br />

A/F FIBERED UNFIBERED<br />

ROOF COATING ASPHALT EMUL<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

X<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class 1 as part of any roof system (indicate yes or no)<br />

4D. FM labelilng on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED X X<br />

X<br />

698


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

HENRY HENRY HENRY HENRY HENRY HENRY<br />

COMPANY COMPANY COMPANY COMPANY COMPANY COMPANY<br />

PRO GRADE #162 PRO GRADE #812 PRO GRADE #818 PRO GRADE #832 PRO GRADE #842 MONSEY<br />

A/F FIBERED A/F FIBERED A/F AQUA BRIGHT UNFIBERED A/F FIBERED MBA GOLD<br />

ASPHALT EMUL ALUM ROOF CTG ALUM ROOF CTG ALUM ROOF CTG ALUM ROOF CTG ADHESIVE<br />

X<br />

X<br />

X<br />

X<br />

A<br />

A A X<br />

X<br />

X<br />

X X X X X X<br />

699


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME HENRY KARNAK<br />

COMPANY CORPORATION<br />

2. PRODUCT NAME GRUNDY #71 AF<br />

FIBERED ROOF ROOF<br />

MASTIC II COATING<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

X<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class 1 as part of any roof system (indicate yes or no)<br />

4D. FM labelilng on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED X<br />

X<br />

700


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

KARNAK KARNAK KARNAK KARNAK KARNAK KARNAK<br />

CORPORATION CORPORATION CORPORATION CORPORATION CORPORATION CORPORATION<br />

#297 AF #501 AF #505 AF #97 #97 AF #98 AF<br />

AQUA-LUM ELASTO-BRITE ELASTO-BRITE FIBERED FIBERED FIBERED<br />

EMUL ALUMINUM M ALUMINUM ALUMINUM ALUMINUM<br />

X<br />

X<br />

X<br />

9 9 9<br />

YES<br />

PENDING PENDING A A A A<br />

YES YES YES<br />

YES YES YES<br />

YES YES YES<br />

701


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME KARNAK KARNAK<br />

CORPORATION CORPORATION<br />

2. PRODUCT NAME #100 AF #169 AF<br />

NON FIBERED NON FIBERED<br />

EMULSION ALUMINUM<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

X<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

X<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9 11<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

A<br />

A<br />

4B. UL labeling on packaging (indicate yes or no) YES YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) YES<br />

4D. FM labelilng on packaging (indicate yes or no) YES<br />

5. SEE APPENDIX IF CHECKED<br />

X<br />

702


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

KARNAK KARNAK KOKEM METACRYLICS METACRYLICS METACRYLICS<br />

CORPORATION CORPORATION PRODUCTS,<br />

INC<br />

#220 AF #108 AF SUNGUARD BLACK CLEAR ACRYLIC<br />

FIBERED ASPHALT PRIMER PRIMER BASE<br />

BRUSH EMULSION PRIMER<br />

YES YES YES<br />

YES YES YES<br />

YES YES YES YES<br />

X<br />

X<br />

X<br />

YES YES YES<br />

YES YES YES<br />

A<br />

A, B<br />

YES YES YES YES YES<br />

NO NO NO<br />

NO NO NO<br />

703


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME METACRYLICS METACRYLICS<br />

2. PRODUCT NAME ACRYLIC ACRYLIC<br />

WHITE GEL MASTIC<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

YES<br />

YES<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

YES<br />

YES<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no) YES YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) NO NO<br />

4D. FM labelilng on packaging (indicate yes or no) NO NO<br />

5. SEE APPENDIX IF CHECKED<br />

YES<br />

YES<br />

YES<br />

YES<br />

YES<br />

YES<br />

704


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

METACRYLICS NEOGARD NEOGARD REPUBLIC REPUBLIC REPUBLIC<br />

POWDERED POWDERED POWDERED<br />

METALS METALS METALS<br />

65 ACRYLIC PERMA-GARD UERTHANE ALUMANATION SOLARGARD SOLARGARD<br />

COLORS FR 7419 R 7441 SERIES 301 ULTRA HYBRID<br />

BASE COAT TOP COAT<br />

YES<br />

YES<br />

YES<br />

YES<br />

X<br />

15<br />

YES<br />

A<br />

A<br />

YES YES YES YES YES YES<br />

NO NO YES NO<br />

NO NO YES NO<br />

705


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME REPUBLIC REPUBLIC<br />

POWDERED POWDERED<br />

METALS<br />

METALS<br />

2. PRODUCT NAME SOLARGARD GEOGARD<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no) YES YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) YES NO<br />

4D. FM labelilng on packaging (indicate yes or no) YES NO<br />

5. SEE APPENDIX IF CHECKED<br />

706


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

SOMAY SOMAY SOMAY SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN<br />

PRODUCTS, PRODUCTS, PRODUCTS, PETROLEUM PETROLEUM PETROLEUM<br />

INC. INC. INC. CORP. CORP. CORP.<br />

#842 #992 #7751 HEAVY FLEX SHIELD GUARDIAN<br />

ELASTOMERIC PATCH & SEAL PRIME & SEAL DUTY PRIMER GENERAL PURPOSE<br />

ROOF MASTIC PRIMER PRIMER<br />

YES YES YES<br />

YES<br />

YES YES YES<br />

NONE NONE NONE NONE NONE NONE<br />

NO NO NO NO NO NO<br />

NO NO NO NO NO NO<br />

NO NO NO NO NO NO<br />

707


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME SOUTHWESTERN SOUTHWESTERN<br />

PETROLEUM PETROLEUM<br />

CORP.<br />

CORP.<br />

2. PRODUCT NAME GUARDIAN HEAVY DUTY<br />

EPDM<br />

ROOF<br />

CLEANER/PRIMER COATING<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

X<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

NONE<br />

NONE<br />

4B. UL labeling on packaging (indicate yes or no) NO NO<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) NO NO<br />

4D. FM labelilng on packaging (indicate yes or no) NO NO<br />

5. SEE APPENDIX IF CHECKED<br />

708


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN SOUTHWESTERN<br />

PETROLEUM PETROLEUM PETROLEUM PETROLEUM PETROLEUM PETROLEUM<br />

CORP. CORP. CORP. CORP. CORP. CORP.<br />

FLEX SHIELD FLEX SHIELD GUARDIAN ALUMINUM ALUMINUM H.D. GRAVEL<br />

ROOF EM ROOF SEAMLESS ROOF ROOF ROOF<br />

COATING COATING ROOF COATING COATING SHIELD PRESERVATIVE<br />

X<br />

X<br />

X<br />

X<br />

9 11<br />

X<br />

NONE NONE NONE NONE NONE NONE<br />

NO NO NO NO NO NO<br />

NO NO NO NO NO NO<br />

NO NO NO NO NO NO<br />

709


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME SPM SUNGUARD<br />

THERMO-SHIELD MARKETING<br />

INC.<br />

C0RP.<br />

2. PRODUCT NAME THERMA-SHIELD SUNGUARD<br />

ROOF<br />

COATING<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

NO<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

A<br />

A, B<br />

4B. UL labeling on packaging (indicate yes or no) YES YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no)<br />

4D. FM labelilng on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

710


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

TAMKO TAMKO TAMKO TAMKO TAMKO TOPCOAT, INC.<br />

ROOFING ROOFING ROOFING ROOFING ROOFING A SUBSIDIARY<br />

PRODUCTS PRODUCTS PRODUCTS PRODUCTS PRODUCTS OF GAF<br />

TAM-PRO TAM-PRO TAM-PRO FIRE TAM-PRO TAM-PRO TOPCOAT<br />

FIBERED ALUM NON FIBERED RATED (FR) FIBERED FIBERED SOLO<br />

ROOF COATING ALUM ROOF CTG FIBER ALUM ROOF COATING EMULSION COAT<br />

X<br />

X<br />

X<br />

X<br />

9 11 9<br />

X<br />

A NONE A NONE A<br />

YES NO YES NO YES<br />

NO NO NO NO<br />

NO NO NO NO YES<br />

711


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME TOPCOAT, INC. TOPCOAT, INC.<br />

A SUBSIDIARY A SUBSIDIARY<br />

OF GAF<br />

OF GAF<br />

2. PRODUCT NAME TOPCOAT TOPCOAT<br />

CRT<br />

MB PLUS<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

A<br />

A<br />

4B. UL labeling on packaging (indicate yes or no) YES YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no)<br />

4D. FM labelilng on packaging (indicate yes or no) YES YES<br />

5. SEE APPENDIX IF CHECKED<br />

712


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

TOPCOAT, INC. TOPCOAT, INC. TOPCOAT, INC. TOPCOAT, INC. TOPCOAT, INC. TOPCOAT, INC.<br />

A SUBSIDIARY A SUBSIDIARY A SUBSIDIARY A SUBSIDIARY A SUBSIDIARY A SUBSIDIARY<br />

OF GAF OF GAF OF GAF OF GAF OF GAF OF GAF<br />

LIQUID FABRIC TOPCOAT FLASHING GRADE ONESTEP FASTENER SURFACE<br />

FLASHING XR-2000 SPRAY GRADE SEAL<br />

GRADE FORMULA SB<br />

A A A A A A<br />

YES YES YES YES YES YES<br />

YES YES YES YES YES YES<br />

713


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME TOPCOAT, INC. TREMCO<br />

A SUBSIDIARY INC.<br />

OF GAF<br />

2. PRODUCT NAME WALLCOATE TREMPRIME<br />

SYSTEM<br />

WB<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

A<br />

4B. UL labeling on packaging (indicate yes or no) YES YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) YES<br />

4D. FM labelilng on packaging (indicate yes or no) YES YES<br />

5. SEE APPENDIX IF CHECKED<br />

714


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

TREMCO TREMCO TREMCO TREMCO TREMCO TREMCO<br />

INC. INC. INC. INC. INC. INC.<br />

DOUBLE DUTY TREMLASTIC HIGH BUILD TREMPRIME TREMLITE TREMLASTIC<br />

ALUMINUM S REFLECTIVE QD LOW ODOR METAL PRIMER<br />

LV ROOF COAT WB<br />

YES<br />

X<br />

X<br />

X<br />

15<br />

NONE<br />

YES YES YES YES NO YES<br />

YES YES YES YES NO YES<br />

YES YES YES YES NO YES<br />

715


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME TREMCO TREMCO<br />

INC.<br />

INC.<br />

2. PRODUCT NAME ECOLASTIC TREMLAR<br />

LRM-H<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no) YES YES<br />

4C. FM Class 1 as part of any roof system (indicate yes or no) YES NO<br />

4D. FM labelilng on packaging (indicate yes or no) YES NO<br />

5. SEE APPENDIX IF CHECKED<br />

716


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

TREMCO TREMCO TREMCO UNITED UNITED UNITED<br />

INC. INC. INC. COATINGS COATINGS COATINGS<br />

TREMLAR TREMLITE POLARCOTE ROOF MATE ROOF SHIELD BERM 600<br />

LRM-V COATING FR<br />

YES<br />

A A A<br />

YES YES YES YES YES YES<br />

NO NO YES YES<br />

NO NO YES YES<br />

717


<strong>Roof</strong> Coatings, Part 2: Technical Data<br />

1. COMPANY NAME UNITED UNITED<br />

COATINGS COATINGS<br />

2. PRODUCT NAME ROOF MATE ROOF MATE<br />

BUTTER<br />

SOLAR<br />

GRADE<br />

CURE<br />

3. COMPLIES WITH:<br />

3A. ASTM C 836-95 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane for Use with Separate Wearing<br />

Surface (no response or indicate yes)<br />

3B. ASTM C 957-93 Standard Specification for High Solids Content, Cold Liquid-<br />

Applied Elas<strong>to</strong>meric Waterproofing Membrane with Integral Wearing Surface (no<br />

response or indicate yes)<br />

3C. ASTM D 41-94 Standard Specification for Asphalt Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3D. ASTM D 43-94 Standard Specification for Coal Tar Primer Used in <strong>Roof</strong>ing,<br />

Dampproofing, and Waterproofing (no response or indicate yes)<br />

3E. ASTM D 1187-97 Standard Specification for Asphalt-Based Emulsions for Use as<br />

Protective Coatings for Metal (indicate Type)<br />

Type I -- Quick-setting<br />

Type II -- Conventional application<br />

3F. ASTM D 1227-95 Standard Specification for Emulsified Asphalt Used as a<br />

Protective Coating for <strong>Roof</strong>ing (indicate Type and Class)<br />

Type I, Class I -- Mineral colloid emulsifying agents and containing asbes<strong>to</strong>s fibers<br />

Type I, Class 2 -- Chemical emulsifying agents and fillers or fibers containing<br />

asbes<strong>to</strong>s<br />

Type II, Class 1 -- Mineral colloid emulsifying agents and containing fillers other<br />

than asbes<strong>to</strong>s<br />

Type II, Class 2 -- Chemical emulsifying agents and containing fillers or fibers other<br />

than asbes<strong>to</strong>s<br />

Type III, Class 1 -- Mineral colloid emulsifying agents without fibrous reinforcement<br />

Type III, Class 2 -- Chemical emulsifying agents without fibrous reinforcement<br />

3G. ASTM D 2923-99 Standard Specification for Asphalt <strong>Roof</strong> Coatings (indicate yes or<br />

no)<br />

3H. ASTM D 2824-94 Standard Specification for Aluminum-Pigmented Asphalt <strong>Roof</strong><br />

Coatings, Non-Fibered, Asbes<strong>to</strong>s Fibered, and Fibered without Asbes<strong>to</strong>s (indicate<br />

Type and metallic aluminum content)<br />

Type I -- Non-fibered<br />

Type II -- Fibered, containing asbes<strong>to</strong>s fibers<br />

Type III -- Fibered, containing no asbes<strong>to</strong>s fibers<br />

Aluminum content, ASTM D 2824, minimum, % Type I: 11; Types II or III: 9<br />

3I. ASTM D 3468-99 Standard Specification for Liquid-Applied Neoprene and<br />

Chlorosulfonated Polyethylene Used in <strong>Roof</strong>ing and Waterproofing (indicate Type<br />

and, if applicable, Grade)<br />

Type I, Grade 1 -- Neoprene<br />

Type I, Grade 2 -- Fiber-modified neoprene<br />

Type II -- CSPE<br />

3J. ASTM D 4479-93 Standard Specification for Asphalt <strong>Roof</strong> Coatings -- Asbes<strong>to</strong>s<br />

Free (indicate Type)<br />

Type I -- Low softening point<br />

Type II -- High softening point<br />

3K. ASTM D 6083-97 Standard Specification for Liquid Applied Acrylic Coating Used in<br />

<strong>Roof</strong>ing (no response or indicate yes)<br />

4. FIRE RESISTANCE CLASSIFICATION:<br />

4A. UL Classificadtion per ANSI/UL 790 as part of any roof system (indicate Class A, B<br />

or C, or none)<br />

4B. UL labeling on packaging (indicate yes or no)<br />

4C. FM Class 1 as part of any roof system (indicate yes or no)<br />

4D. FM labelilng on packaging (indicate yes or no)<br />

5. SEE APPENDIX IF CHECKED<br />

YES<br />

YES<br />

A<br />

718


Appendix, <strong>Roof</strong> Cements and Adhesives, and Coatings<br />

HENRY COMPANY<br />

For all cements, coatings and adhesives sales<br />

information, contact Walt Mullen at 800/523-0268 or<br />

for technical information, contact Skip Leonard at<br />

800/486-1278. Henry’s web site www.henry.com can<br />

also be used <strong>to</strong> obtain techncial or sales information.<br />

Consult Henry Company for latest UL and FM<br />

listing.<br />

UL classifications are the highest for the product<br />

or system. Other classifications may be available<br />

depending on the substrate and system components.<br />

#111 Insulboard <strong>Roof</strong> Insulation Adhesive is a<br />

solvent-free rubberized asphalt emulsion formulated<br />

for laminating solvent-sensitive polystyrene foam<br />

boards, many other insulations and substrates. Refer<br />

<strong>to</strong> current data sheet for acceptable materials and<br />

approved application methods.<br />

RubberKote is a coating for EPDM and CSPE<br />

membranes <strong>to</strong> enhance reflectivity and membrane<br />

longevity.<br />

The following products have Energy Star approval:<br />

Henry #280 White Elas<strong>to</strong>meric, Henry #869<br />

Elas<strong>to</strong>meric Aluminum <strong>Roof</strong> Coating, Henry #275/276<br />

Metalshield Metal <strong>Roof</strong> Coating, Henry<br />

RubberKote, and Henry ProGrade #550<br />

Elas<strong>to</strong>meric White <strong>Roof</strong> Coating.<br />

NATIONAL COATINGS CORP.<br />

Acryshield complies with ASTM D 6083-97A,<br />

Standard Specification For Liquid Applied Acrylic<br />

Coating Used in <strong>Roof</strong>ing. Acryflex complies with both<br />

ASTM C920-98, Standard Specification for<br />

Elas<strong>to</strong>meric Joint Sealants and Federal<br />

Specification TT-S-00230C, Class A.<br />

719


Section 5<br />

<strong>Roof</strong> Membrane Warranties


Information on Section 5: <strong>Roof</strong> Membrane Warranties<br />

General Information<br />

Section 5: <strong>Roof</strong> Membrane Warranties in the 2001<br />

edition of NRCA’s Low-Slope <strong>Roof</strong>ing Materials Guide<br />

provides information on warranties offered by<br />

material manufacturers applicable <strong>to</strong> their built-up,<br />

modified bitumen, and single-ply membrane products<br />

listed. The information is derived from two sources:<br />

an examination of the warranty or guarantee<br />

document itself and the manufacturer’s responses <strong>to</strong><br />

a questionnaire sent by NRCA.<br />

All manufacturers with the referenced categories of<br />

membrane products appearing in the guide are<br />

invited <strong>to</strong> submit their warranties for examination and<br />

listing. Those without warranty listings have elected<br />

not <strong>to</strong> participate.<br />

For each warranty there are 27 categories, or items,<br />

of information listed. The information provided in the<br />

following categories was obtained by examination of<br />

the document itself:<br />

No.<br />

Item of Information<br />

1 Identity of issuing entity<br />

4 Scope of coverage<br />

6 Nature of remedy<br />

8 Notification of requirements<br />

9 Exclusive of additional remedy<br />

10 Inclusion of consequential damages<br />

11 Determination of warranty applicability<br />

12 Specific exclusions from coverage<br />

14 Specific conditions <strong>to</strong> make warranty<br />

ineffective or null and void<br />

25 Assignability<br />

26 Special features/conditions<br />

27 Executed by owner<br />

In addition, information in the following categories was<br />

provided by the manufacturer in response <strong>to</strong> a<br />

questionnaire accompanying the warranty document.<br />

No.<br />

Item of Information<br />

2 Title, original publication date, and<br />

identifying symbol (if any)<br />

3 Product specification<br />

5 Length of coverage<br />

13 Wind coverage/exclusion<br />

15 Cost <strong>to</strong> obtain<br />

16 Minimum charge<br />

18 Pre-construction notice and approval<br />

requirement<br />

19 Approved, authorized, or licensed contrac<strong>to</strong>r<br />

20 Job inspection policy<br />

21 Contrac<strong>to</strong>r’s post-installation obligation<br />

23 Issuing entity manufacturers and/or sells<br />

products<br />

24 Conditions for renewal or extension<br />

In response <strong>to</strong> this information, NRCA endeavors <strong>to</strong><br />

prepare an accurate, comprehensive, and objective<br />

listing for each warranty submitted by a manufacturer.<br />

Generally, a separate listing is generated for each<br />

document; sometimes, however, a manufacturer uses<br />

the same warranty document <strong>to</strong> cover different<br />

roofing systems, specifications, or products, and in<br />

addition, the lengths of coverage, the cost <strong>to</strong> obtain it,<br />

the minimum charge, or the monetary limitations may<br />

vary. In such cases, there may be more than one<br />

listing for a particular warranty reflecting these<br />

differences.<br />

A blank space appears for a category of information<br />

if a manufacturer does not provide the relevant data.<br />

Brackets ([ ]) are used in the listing <strong>to</strong> indicate<br />

information that a manufacturer feels is pertinent but<br />

may not be contained in the document or at least was<br />

not apparent <strong>to</strong> NRCA in its review. In effect, the use<br />

of bracketed statements provides a means for<br />

manufacturers <strong>to</strong> disagree with the analysis made of<br />

the document by NRCA; in some instances, these<br />

statements may even contradict NRCA’s conclusions<br />

concerning the import of language in a warranty.<br />

It should be noted that the name of the manufacturer<br />

as it appears in Item 1, Issuing Entity, may not<br />

necessarily be identical <strong>to</strong> or even the same as the<br />

one listed in the membrane index or elsewhere in the<br />

membrane section. This is because the name<br />

appearing in the warranty section is the name of the<br />

entity appearing in the warranty document itself. For<br />

example, if a manufacturer changes its corporate<br />

name but does not change a warranty document that<br />

bore its original name, the original name will appear<br />

in the warranty section. Or if one company purchases<br />

the assets of another, upon request NRCA simply<br />

moves the name of the company that acquired it. In<br />

the warranty section, on the other hand, this is not<br />

possible until warranty documents bearing the new<br />

corporate name are provided <strong>to</strong> NRCA. The name<br />

of the entity must remain as it appears in the<br />

723


document. An explanation of such situations is 3. Product, specification, or system covered:<br />

sometimes provided in a footnote in the warranty This is an enumeration of the manufacturer’s<br />

section in order <strong>to</strong> clarify an apparent discrepancy in products, roof specification, or roofing systems that<br />

its corporate name.<br />

are covered by the warranty. If properly updated by<br />

the manufacturer, the reader should be able <strong>to</strong><br />

identify these product listings in the membrane<br />

section.<br />

By necessity, the warranty listing in the guide<br />

presents rather succinctly a great deal of information<br />

contained in the manufacturers’ warranties, as well as<br />

the policies surrounding them. For this reason, the<br />

reader should obtain and examine the warranty<br />

document itself, discuss additional questions with a<br />

representative of the party issuing the warranty, and<br />

obtain professional advice from counsel when<br />

desired. A warranty has significant legal<br />

consequence; therefore, all parties should<br />

understand the document at the outset of a<br />

construction project <strong>to</strong> preclude subsequent<br />

misunderstandings.<br />

The firm of Hendrick, Phillips, Schemm & Salzman,<br />

Atlanta, Ga., in coordination with NRCA staff prepares<br />

the warranty section of the Low-Slope <strong>Roof</strong>ing<br />

Materials Guide.<br />

Understanding the Warranty Listing<br />

Following are descriptions of the kind of data that is<br />

contained in the 27 categories of information included<br />

in each warranty listing.<br />

1. Identity of issuing entity: This is the name of the<br />

legal entity that issues and is obligated <strong>to</strong> honor the<br />

warranty document. In most cases, this entity is the<br />

manufacturer of the product covered by the warranty<br />

(but see the explanation of item 23 for more<br />

information in this regard.)<br />

2. Title, original publication date, and identifying<br />

symbol (if any): The title listed is the title printed on<br />

the warranty document. The original publication date<br />

is the date that the manufacturer first promulgated the<br />

warranty form; the document may subsequently be<br />

reprinted in the exact same form. Some<br />

manufacturers' warranties contain an identifying<br />

symbol, or code, that is frequently a combination of<br />

numbers and letters, usually in the bot<strong>to</strong>m right-hand<br />

or left-hand corner of the document. This identifying<br />

symbol indicates the precise document that was<br />

reviewed by NRCA. (For the reader <strong>to</strong> be certain that<br />

the warranty document he has in his possession is the<br />

same one listed in the guide, the title of the document<br />

and the identifying symbol, if any, should match<br />

exactly.)<br />

4. Scope of coverage: In most cases, the initial<br />

portion of this entry will be either material and<br />

workmanship or material only* (Material and<br />

workmanship indicates that the warranty covers both<br />

a defect in the materials supplied by the manufacturer<br />

and a deficiency in the workmanship of the<br />

application. The term workmanship refers <strong>to</strong> the<br />

workmanship of the contrac<strong>to</strong>r and is meant <strong>to</strong><br />

indicated whether proper or defective workmanship<br />

on the part of the roofing contrac<strong>to</strong>r/applica<strong>to</strong>r is<br />

encompassed under the manufacturer’s warranty.)<br />

After this entry is made, ensuing information supplied<br />

in this category usually corresponds <strong>to</strong> the language<br />

used in the warranty document. Virtually all roof<br />

membrane warranties provide only for repairs <strong>to</strong><br />

leaks, regardless of whether they cover materials only<br />

or materials and workmanship.<br />

*Note: If the manufacturer’s warranty covers defective<br />

material and the remedy includes replacement of the<br />

defective material plus labor necessary <strong>to</strong> replace that<br />

defective material with the new material, but the<br />

warranty does not state that a leak caused by<br />

improper application on the roofing applica<strong>to</strong>r is<br />

covered, the initial entry under scope of coverage will<br />

not state material and workmanship. The fact that<br />

the manufacturer will provide the labor necessary <strong>to</strong><br />

replace defective material is covered under Item 6<br />

Nature of Remedy.<br />

5. Length of coverage: This is the number of years<br />

for which the manufacturer will issue the warranty. In<br />

most instances, this period commences upon the<br />

completion of the roof installation final inspection and<br />

approval by the manufacturer. In a few instances,<br />

particularly in cases of material-only warranties, the<br />

coverage period may begin at the time of sale or<br />

invoice date.<br />

6. Nature of remedy: This states what action the<br />

manufacturer will take in the event that there is a<br />

problem with the roof covered under the warranty.<br />

The language used in this category generally<br />

parallels that appearing in the warranty document.<br />

For most roof membrane warranties, the remedy<br />

provided is the repair of leaks.<br />

724


7. Monetary limitations: The information provided warranty document. If the warranty states that it is an<br />

for this category indicates whether a warranty exclusive warranty and is issued in lieu of all other<br />

contains a monetary limitation of the manufacturer’s warranties, the claimant may not be entitled <strong>to</strong> seek<br />

obligation under its warranty. The phrase none recovery from the manufacturer based on the breach<br />

stated indicates that there is no monetary limitation of any other warranties, express or limited.<br />

stated in the document, meaning that the<br />

manufacturer is obligated <strong>to</strong> spend whatever sum is The manufacturer’s warranty may exclude or seek <strong>to</strong><br />

necessary in order <strong>to</strong> honor its warranty. Although exclude the implied and express warranties<br />

most commercial roofing warranties in use <strong>to</strong>day do established by the Uniform Commercial Code (UCC).<br />

not contain specific penal sum limitations (as The UCC, as adopted in most states, provides that a<br />

his<strong>to</strong>rically was included in roofing bonds offered by warranty is implied in a contract for sale of goods that<br />

roofing materials manufacturers and their sureties), the goods shall be merchandise if the seller is a<br />

many warranties limit the manufacturer’s liability over merchant of goods of that kind. To be merchantable,<br />

the life of the warranty <strong>to</strong> the owner’s original cost of goods must be fit at least for the ordinary purpose of<br />

the installed roof system. Some warranties, which such goods are used, must conform <strong>to</strong> the<br />

particularly material-only ones, are limited <strong>to</strong> the promises or affirmations made on the container or<br />

original purchase price of the materials; others are label, and must pass without objection in the trade<br />

limited <strong>to</strong> a particular per-square amount based on under the contract description. An implied warranty<br />

the size of the roof. The existence of or the amount of fitness for a particular purpose is created under the<br />

of a monetary limitation may be dependent upon the UCC when the seller at the time of contracting has<br />

specific manufacturer’s specification or product used. reason <strong>to</strong> know any particular purpose for which the<br />

If the manufacturer prorates the maximum amount goods as required and that the buyer is relying on the<br />

available over the life of the warranty, prorating seller’s skill or judgment <strong>to</strong> select or furnish suitable<br />

information is included as well. The prorating is goods.<br />

usually expressed in terms of a percentage available<br />

in the later years of a roof warranty.<br />

In addition <strong>to</strong> those implied warranties, the UCC<br />

provides that express warranties are created when<br />

the seller (1) makes an affirmation of fact or promise<br />

<strong>to</strong> the buyer that relates <strong>to</strong> the goods and becomes a<br />

part of the basis of the bargain; (2) gives a<br />

description of the goods that is made part of the basis<br />

of the bargain; (3) provides a sample or model of the<br />

goods that is made a part of the basis of the bargain.<br />

8. Notification requirements: In this category is<br />

information concerning the action that an owner or<br />

other claimant is <strong>to</strong> take in order <strong>to</strong> make a warranty<br />

claim; of particular importance is the prescribed time<br />

period in which a leak or defect is <strong>to</strong> be reported <strong>to</strong><br />

the manufacturer. If the warrant contains specific<br />

notification requirements, they are set forth here.<br />

Most warranties require that claimants provide the<br />

manufacturer with written notice of a warranty claim<br />

within 30 days of the discovery of a leak or purported<br />

defect. Some warranties require notice within 10 days<br />

and/or that written notice be sent by registered or<br />

certified mail.<br />

9. Exclusive or additional remedy: Under general<br />

legal principles, unless the warranty document<br />

specifically excluded other warranties and remedies<br />

that may be available <strong>to</strong> the owner and the owner<br />

agrees <strong>to</strong> be bound by the warranty terms, the rights<br />

and remedies set forth in the warranty document are<br />

in addition <strong>to</strong> those warranties, rights and remedies<br />

that may be available <strong>to</strong> the owner or other claimant<br />

under state statu<strong>to</strong>ry or common law. In addition <strong>to</strong><br />

providing an owner with specific rights, warranty<br />

documents are frequently used as a liability-limiting<br />

device so that the liability of the party issuing the<br />

warranty is limited <strong>to</strong> what is prescribed in the<br />

UCC implied warranties may be excluded in<br />

accordance with the requirements set forth in the<br />

Uniform Commercial Code.<br />

In addition <strong>to</strong> seeking <strong>to</strong> make the warranty an<br />

exclusive warranty, a manufacturer’s warranty may<br />

seek <strong>to</strong> limit the other remedies that the law would<br />

otherwise make available <strong>to</strong> a claimant. A warranty<br />

that states that it is the owner’s exclusive remedy<br />

might limit the claimant’s rights <strong>to</strong> the terms of the<br />

warranty and preclude a claim based on another legal<br />

theory of liability. Some warranty documents state<br />

that remedy provided in the warranty is the owner’s<br />

“sole and exclusive remedy” and is the manufacturer’s<br />

sole liability and obligation in the event of a roof<br />

problem regardless of whether the<br />

owner might otherwise be entitled <strong>to</strong> pursue a legal<br />

claim for breach of contract, negligence or another<br />

legal theory of recovery.<br />

725


The purpose of the category Exclusive or Additional<br />

Remedy is <strong>to</strong> give the reader an indication as <strong>to</strong> how<br />

the manufacturer’s warranty may impact other<br />

warranties and remedies that may be available <strong>to</strong> an<br />

owner. The phrase excludes UCC warranties in this<br />

category means that it appears that the warranty<br />

document complies with the UCC requirement <strong>to</strong><br />

exclude warranties established under the Uniform<br />

Commercial Code.<br />

Inclusion of consequential damages: The word no<br />

in this category indicates that the warranty does not<br />

have <strong>to</strong> cover consequential damages that may result<br />

from a roof leak, such as damage <strong>to</strong> the interior of the<br />

building. The majority of roof warranties expressly<br />

exclude consequential damages.<br />

Determination of warranty applicability: Some<br />

warranties state explicitly that the manufacturer has<br />

the right <strong>to</strong> determine whether a leak is covered or<br />

excluded from warranty coverage. The entry<br />

manufacturer’s determination indicates that the<br />

manufacturer reserves <strong>to</strong> itself the right <strong>to</strong> determine<br />

whether a leak is covered or excluded from warranty<br />

coverage. Under these circumstances, the<br />

manufacturer’s determination may be binding, even if<br />

it is erroneous and regardless of whether other<br />

parties disagree, provided that the manufacturer’s<br />

determination was made in good faith. If the entry in<br />

this category states neutral (no provision), the<br />

manufacturer’s warranty does not contain an explicit<br />

provision giving it the right <strong>to</strong> determine whether the<br />

warranty is or is not applicable <strong>to</strong> a problem. In the<br />

event of a dispute concerning the warranty’s<br />

applicability, a neutral party would ultimately decide<br />

whether the warranty is applicable in this case.<br />

12. Specific exclusions from coverage: Most<br />

roofing warranties state the leaks resulting from<br />

certain enumerated caused (e.g., natural disasters,<br />

<strong>to</strong>rnadoes, abuse or misuse) will not be covered. A<br />

numeric code is used in this category <strong>to</strong> reference<br />

specific exclusions from coverage, a key for which is<br />

provided below. The list of specific exclusions is a<br />

compilation of those appearing in the warranty<br />

documents submitted <strong>to</strong> NRCA; the language<br />

appearing in the index is not necessarily the exact<br />

language appearing in a specific warranty document,<br />

but it reflects the same exclusion.<br />

The absence of a specific exclusion from coverage<br />

does not necessarily mean that a warranty will be<br />

applicable <strong>to</strong> a condition or occurrence not<br />

specifically excluded. The applicability of the<br />

warranty will generally be determined from the<br />

information contained under the category Scope of<br />

Coverage.<br />

Index of Specifically Enumerated Exclusion from<br />

Coverage<br />

1. Natural disasters and acts of God (lightning,<br />

<strong>to</strong>rnadoes, earthquakes)<br />

2. Hail<br />

3. Acts of negligence, abuse or misuse, accidents,<br />

vandalism, civil disobedience, war<br />

4. Damage by structural failure, settlement,<br />

movement, dis<strong>to</strong>rtion, warpage, displacement of<br />

structure<br />

5. Failure of the material and/or metal work not<br />

supplied by the manufacturer issuing the<br />

warranty; movement of metal work<br />

6. Repairs or alterations of roof or installation of<br />

structures, fixtures, or utilities on or through roof<br />

without prior approval of manufacturer<br />

7. Defects in, failure or improper application of, roof<br />

insulation, roof deck, or any other underlying<br />

surface or material used as a base over which<br />

the roof is applied<br />

8. Change in usage of building without prior written<br />

approval of manufacturer<br />

9. Traffic or s<strong>to</strong>rage of materials on roof<br />

10. Moisture entering roof system through walls,<br />

copings, or any part of the building structure,<br />

including adjacent building<br />

11. Damage resulting from lack of positive, proper,<br />

or adequate drainage; ponding on the roof<br />

12. Negligence or failure of owner <strong>to</strong> use reasonable<br />

care in maintenance of roof or failure <strong>to</strong> follow<br />

manufacturer’s maintenance specifications<br />

13. Environmental fallout, chemical attack or use<br />

within building of commercial or industrial<br />

solvents, acids, caustic fluids, oils, waxes,<br />

greases, absorbent clays, or plasticizers<br />

14. Discoloration or change in usual appearance<br />

due <strong>to</strong> acceleration or streaking of dirt or other<br />

airborne material.<br />

15. Repairs performed or materials furnished by<br />

others in correcting leaks unless specifically<br />

authorized and approved by manufacturer;<br />

unauthorized repairs; roof maintenance for<br />

corrections other than leaks<br />

16. Fire<br />

17. Faulty construction or design of building,<br />

including parapet walls, copings, chimneys,<br />

skylights, vents, or roof deck<br />

18. Contaminants that may have not been<br />

approved first or accepted by manufacturer;<br />

726


exposure <strong>to</strong> or contact with damaging<br />

substances or deteriorating substances or<br />

agents<br />

19. Defects or failure caused by misapplication of<br />

materials or by application not in strict<br />

adherence with roofing specification, application<br />

instructions, and approved practices<br />

20. Installation of roofing membrane<br />

21. Abnormal climatic conditions<br />

22. Infiltration or condensation of moisture in or<br />

through underlying area; vapor condensation<br />

beneath the roof<br />

23. Damages caused by falling objects<br />

24. Acts of parties other than manufacturer or<br />

unauthorized roofing contrac<strong>to</strong>r<br />

25. Penetration of the roof membrane by vegetation<br />

13. Wind coverage/exclusion: The purpose of this<br />

category is <strong>to</strong> convey the manufacturer’s policy in<br />

regard <strong>to</strong> whether damage <strong>to</strong> the roof caused by wind<br />

is covered under the warranty. The information<br />

presented is based upon an examination of the<br />

warranty document <strong>to</strong> determine if it addresses the<br />

issue of leaks, damages, or conditions resulting from<br />

wind and the manufacturer’s response <strong>to</strong> questions<br />

concerning this issue.<br />

Many manufacturers’ warranties list either gales,<br />

strong gales, wind s<strong>to</strong>rm, and/or hurricanes and<br />

<strong>to</strong>rnadoes as examples of natural disaster or acts of<br />

God that are specifically excluded from warranty<br />

coverage. In order <strong>to</strong> provide more specific,<br />

affirmative information regarding the manufacturer’s<br />

policy concerning wind coverage, NRCA asks<br />

manufacturers <strong>to</strong> identify the wind speed that is<br />

covered by each of their warranties or <strong>to</strong> state that<br />

the warranty does not cover damage <strong>to</strong> the roof<br />

caused by wind regardless of speed – meaning that<br />

any damage resulting from wind, even at extremely<br />

low speeds, is excluded from the warranty coverage.<br />

The second sentence under Wind Coverage<br />

exclusion category, based on NRCA’s questions<br />

indicates what speeds, if any, the manufacturer<br />

covers. If NRCA believes that the manufacturer’s<br />

response is potentially inconsistent with the wind<br />

exclusions stated in the warranty or creates an<br />

ambiguity, the manufacturer’s response is included in<br />

brackets. If the warranty document does not address<br />

the subject of wind, the information is based<br />

exclusively upon the manufacturer’s<br />

responses <strong>to</strong> the NRCA wind questions. If the<br />

manufacturer does not respond <strong>to</strong> the wind questions<br />

but the warranty addresses the subject of wind, the<br />

information is based exclusively on an examination of<br />

the warranty document. If the category remains<br />

blank, the warranty does not address the wind issue<br />

and the manufacturer did not respond <strong>to</strong> the wind<br />

questions.<br />

For example, a warranty may indicate that repairs,<br />

alterations, or additions without the prior approval of<br />

the manufacturer make the warranty null and void;<br />

this differs from the statement that a leak resulting<br />

from a repair or alteration not previously approved by<br />

the manufacturer is excluded, or not covered, under<br />

the warranty. An alphabetic code is used in this<br />

category <strong>to</strong> reference specific conditions <strong>to</strong> make<br />

warranty ineffective or null and void; a key for which<br />

follows. The list of specific conditions is a compilation<br />

of conditions that appear in roof warranties submitted<br />

<strong>to</strong> NRCA; the language appearing in the various<br />

conditions is not necessarily the exact language<br />

appearing in a specific warranty document.<br />

14. Index of Specific Conditions <strong>to</strong> Make<br />

Warranty Ineffective or Null and Void<br />

A. Lack of inspection at time of application or<br />

owner’s refusal <strong>to</strong> allow inspection.<br />

B. Repairs, alterations, and additions without prior<br />

approval of manufacturer.<br />

C. Failure of the owner <strong>to</strong> pay all bills for roof<br />

installation and materials.<br />

D. Failure <strong>to</strong> notify within specified number of days<br />

or transfer of ownership.<br />

E. Failure <strong>to</strong> submit accurate, completed inspection<br />

report or checklist, within prescribed time period<br />

F. Failure <strong>to</strong> use reasonable care in maintenance;<br />

failure <strong>to</strong> follow manufacturer’s maintenance<br />

instructions.<br />

G. Failure <strong>to</strong> comply with terms and conditions of<br />

warranty.<br />

H. Failure <strong>to</strong> notify manufacturer within prescribed<br />

time of discovery of leak.<br />

I. Owner’s unwillingness <strong>to</strong> accept manufacturer’s<br />

warranty in lieu of all other remedies and <strong>to</strong><br />

return signed copy <strong>to</strong> manufacturer; owner’s<br />

failure <strong>to</strong> execute the warranty.<br />

J. Change in building usage or a significant change<br />

in use of building affecting roof membrane.<br />

727


K. Assignment of warrant without written approval of<br />

manufacturer.<br />

L. Lack of validation by manufacturer.<br />

M. Failure of owner <strong>to</strong> make repairs <strong>to</strong> leaks not<br />

covered by manufacturer’s warranty.<br />

N. Repair work by any contrac<strong>to</strong>r other than<br />

approved contrac<strong>to</strong>r or use of unapproved<br />

contrac<strong>to</strong>r.<br />

O. Building is used in any manner or for any purpose<br />

other than the purpose for which it was intended.<br />

P. <strong>Roof</strong> is used as a promenade or work deck.<br />

Q. <strong>Roof</strong> is flooded.<br />

R. Membrane or materials supplied by manufacturer<br />

are not applied according <strong>to</strong> manufacturer’s<br />

specifications or instructions.<br />

S. Failure <strong>to</strong> repair damaged roof within specified<br />

time period, by approved applica<strong>to</strong>r.<br />

15. Cost <strong>to</strong> obtain: This is the amount, if any, that<br />

the manufacturer charges <strong>to</strong> obtain the warranty. The<br />

word None entered in this category means that there<br />

is no separate charge, apart from the cost of<br />

purchasing materials, for the warranty. When there is<br />

a separate charge, it will generally be stated on a persquare<br />

(100 square feet) basis.<br />

16. Minimum charge: If the manufacturer has a<br />

minimum charge policy for obtaining the warranty, the<br />

amount will be entered in this category.<br />

17. Ineligible structures or building use: If the<br />

manufacturer does not offer its warranties for roofs on<br />

certain types of buildings or for buildings used for<br />

certain purposes, the types of structures or uses<br />

ineligible for warranty coverage will be listed here.<br />

Private residences may not be eligible for warranty<br />

coverage even though a specific exclusion is not<br />

listed. Generally manufacturers with a warranty that<br />

excludes residential properties intend <strong>to</strong> exclude<br />

single-family homes and similar structures, but they<br />

may still offer the warranty for apartment buildings,<br />

cooperatives, or condominium properties.<br />

18. Pre-construction notice and approval<br />

requirements: This category is where it is noted<br />

whether the manufacturer requires that it give notice<br />

and approval prior <strong>to</strong> construction if the warranty is <strong>to</strong><br />

be obtained at the completion of the roofing<br />

installation. The pre-construction notice and<br />

approval requirements, where applicable, generally<br />

pertain <strong>to</strong> the procedure <strong>to</strong> be employed by the<br />

roofing contrac<strong>to</strong>r prior <strong>to</strong> commencing application.<br />

19. Approved, authorized, or licensed<br />

applica<strong>to</strong>rs: Most manufacturers require that the<br />

roof be installed by a roofing contrac<strong>to</strong>r who is<br />

“approved,“ “authorized,” or “licensed” by the<br />

manufacturer in order for the warranty <strong>to</strong> be obtained.<br />

The entry of Yes here means that the contrac<strong>to</strong>r must<br />

be so approved, authorized, or licensed. (The nature<br />

of the relationship between the manufacturer and the<br />

contrac<strong>to</strong>r is frequently defined in a separate<br />

contract.) The entry of No indicates that the<br />

manufacturer does not require the use of a contrac<strong>to</strong>r<br />

approved, authorized or licensed by the manufacturer<br />

in order for the warranty <strong>to</strong> be obtained.<br />

20. Job-inspection policy: This category<br />

encompasses in a summary manner the jobinspection<br />

policy, if any, of the manufacturer and is<br />

where it will be indicated if the manufacturer’s<br />

representative makes an on-site inspection prior,<br />

during, or upon completion of application, as well as<br />

some time after application. In this category it will also<br />

be indicated whether there is an inspection charge or<br />

fee for any on-site job inspections.<br />

21. Contrac<strong>to</strong>r’s post-installation obligation:<br />

This category briefly covers the manufacturer’s policy<br />

regarding an obligation by the contrac<strong>to</strong>r <strong>to</strong> make<br />

repairs after issuance of the warranty. While the<br />

manufacturer’s warranty itself rarely makes a<br />

reference <strong>to</strong> any obligation by the contrac<strong>to</strong>r <strong>to</strong> make<br />

repairs, there may be a separate agreement between<br />

the manufacturer and the contrac<strong>to</strong>r concerning such<br />

an obligation.<br />

22. Backed by name insurance or surety<br />

company: In this category it will be indicated whether<br />

an insurance company or surety is listed on the face<br />

of the warranty document and whether the<br />

manufacturer has insurance applicable <strong>to</strong> its warranty<br />

obligations. The entry of No indicates that no surety<br />

or insurance company is named on the face of the<br />

warranty document, meaning that the owner or other<br />

claimant would not be entitled <strong>to</strong> assert a claim<br />

against an insurance company or surety in the event<br />

the manufacturer was unable <strong>to</strong> satisfy its warranty<br />

commitments.<br />

NRCA also asks manufacturers if they carry insurance<br />

covering their warrant obligations, and, if so, the type<br />

and amount of coverage. The manufacturer’s<br />

response is included as the second part of the<br />

information provided in this category.<br />

728


23. Issuing entity manufactures and/or sells<br />

products: In this category is indicated whether the<br />

entity issuing the warranty is both the manufacturer<br />

and seller of the roofing materials covered under the<br />

warranty or whether the party issuing the warranty is<br />

only the seller of these materials. The information is<br />

supplied <strong>to</strong> NRCA in response <strong>to</strong> a question<br />

concerning this issue.<br />

24. Conditions for renewal or extension: In this<br />

category is indicated whether a manufacturer’s<br />

warranty can be extended or renewed and, if so, the<br />

procedures <strong>to</strong> be employed as well as additional costs<br />

incurred in doing so.<br />

25. Assignability: Like other legal documents,<br />

warranties can generally be “assigned” or<br />

“transferred” by one party <strong>to</strong> another, unless there is<br />

a specific prohibition against such assignment. Some<br />

roofing warranties contain such prohibitions, and<br />

some state specifically that no assignment or transfer<br />

will be allowed without the prior written permission of<br />

the manufacturer. The phrase No restrictions stated<br />

indicates that the warranty contains no provisions<br />

barring, limiting, or conditioning the owner’s right <strong>to</strong><br />

assign the warranty <strong>to</strong> a subsequent building owner,<br />

tenant, or other party.<br />

26. Special features/conditions: In this category<br />

are relatively unique or unusual features, conditions,<br />

or limitations. This category is generally based on the<br />

warranty document itself, but sometimes may be<br />

based on information supplied by the manufacturer.<br />

27. Executed by owner: In this category is indicated<br />

whether the manufacturer’s warranty form states on<br />

its face that it is <strong>to</strong> be signed by the owner. Requiring<br />

the roofing warranty <strong>to</strong> be executed by the owner<br />

makes it more likely the owner will be bound <strong>to</strong> the<br />

terms and conditions set forth in the document<br />

in the event that a question subsequently<br />

arises as <strong>to</strong> whether the owner agreed<br />

<strong>to</strong> the terms and conditions in the warranty.<br />

729


Index <strong>to</strong> Warranties<br />

WARRANTIES<br />

INCOMPLETE<br />

INCOMPLETE<br />

WARRANTIES<br />

AMERICAN LUBRICANTS CO. 734 CERTAINEED / <strong>Roof</strong>ing Products 833<br />

1227 Deeds Avenue 750 E. Swedsford Road<br />

Day<strong>to</strong>n, OH 45401 P.O. Box 860<br />

937/222-2851 Valley Forge, PA 19482<br />

FAX: 937/461-7729 800/359-7298<br />

E-mail: FAX: 610/341-7055<br />

Web:<br />

Web: www.certainteed.com<br />

BARRETT COMPANY 734 CONKLIN CO. 744<br />

3422 Old Capi<strong>to</strong>l Trail P.O. Box 155<br />

Wilming<strong>to</strong>n, DE 19808 Shakopee, MN 55379-0155<br />

800/647-0100 800/888-8838<br />

FAX: 908/647-0278 FAX: 952/496-4285<br />

E-mail:<br />

E-mail: marketing@conklin.com<br />

Web: barrettroofs.com<br />

Web: www.conklin.co<br />

BAKOR, Div of Henry Company 833 DANOSA CARIBBEAN, INC. 746<br />

284 Watkline Road Box 13757, Santurce Station<br />

Mississauga, ON L4Z 1P4 San Juan, PR 00908<br />

CANADA 809/785-4545<br />

905/890-4800 FAX: 809/787-3092<br />

FAX: 905/890-4886<br />

E-mail: danosapr@icepr.com<br />

Web: www.bakor.com<br />

Web:<br />

BITEC INC. 738 DERMABIT WATERPROOFING IND. 748<br />

#2 Industrial Park Drive P.O. Box 3952<br />

Morril<strong>to</strong>n, AR 72110 Greenville, DE 19807<br />

800/535-8597 302/652-2740<br />

FAX: 501/354-3019 FAX: 302/652-0195<br />

E-mail: dga@bitec.com<br />

E-mail:<br />

Web: www.bi-tec.com<br />

Web: www.dewitt@globalbiz.com<br />

BONDCOTE ROOFING SYSTEMS 740 DIBITEN 748<br />

4090 Pepperell Way P.O. Box 5108<br />

Dublin VA 24084 Denver, CO 80217-5108<br />

800/368-2160 800/342-4836<br />

FAX: 540/674-6511 FAX: 303/978-3904<br />

E-mail: bcrtech@bondcote.com<br />

E-mail:<br />

Web: www.bondcote.com<br />

Web:<br />

CARLISLE SYNTEC INC. 740 DURO-LAST INC. 752<br />

P.O. Box 7000 525 Morley Drive<br />

Carlisle, PA 17013 Saginaw, MI 48601<br />

717/245-7000 800/248-0280<br />

FAX: 717/245-7245 FAX: 800/432-9331<br />

E-mail:<br />

E-mail: disagmi@concentric.com<br />

Web: carlislesyntec.com<br />

Web: www.duro-last.com<br />

CELOTEX CORP. 742 ECOLOGY ROOF SYSTEMS 833<br />

4010 Boy Scout Blvd. 505 N. Tustin Avenue, #188<br />

Tampa, FL 33607 Santa Ana, CA 92705<br />

813/873-1700 714/972-1001<br />

FAX: 813/873-4080 FAX: 714/972-1079<br />

E-mail:<br />

E-mail:<br />

Web:<br />

Web: www.ecologyroofsystems.com<br />

730


Index <strong>to</strong> Warranties<br />

WARRANTIES<br />

INCOMPLETE<br />

INCOMPLETE<br />

WARRANTIES<br />

ERSYSTEMS 754 HENRY COMPANY 770<br />

Elas<strong>to</strong>meric <strong>Roof</strong>ing Systems, Inc.<br />

2911 Slauson Avenue<br />

50 Medina Street Hunting<strong>to</strong>n Park, CA 90255<br />

Loret<strong>to</strong>, MN 55357-0056 323/583-5000<br />

612/479-6690 FAX: 612/479-6691 FAX: 323/582-6429<br />

E-mail: ersinfo@ersystems.com<br />

E-mail:<br />

Web: www.ersystems.com<br />

Web: www.henry.com<br />

FIELDS COMPANY, LLC 833 HERBERT MALARKEY COMPANY 774<br />

2240 Taylor Way P.O. Box 17217<br />

Tacoma, WA 98421 Portland, OR 97217-0217<br />

253/627-4098 503/283-1191 or 800/545-1191<br />

FAX: 253/383-2181 FAX: 503/289-7644<br />

E-mail:<br />

E-mail:<br />

Web:<br />

Web: www.malarkey-rfg.com<br />

FIRESTONE BUILDING PRODUCTS CO. 756 HONEYWELL INTERNATIONAL 834<br />

525 Congressional Blvd. 2000 Regency Parkway, Suite 225<br />

Carmel, IN 46032 Cary, NC 27511-8507<br />

800/428-4442 800/221-6490<br />

FAX: 317/575-7100<br />

FAX:<br />

E-mail: fires<strong>to</strong>nebpco.com<br />

E-mail:<br />

Web: www.fires<strong>to</strong>nebp.com<br />

Web:<br />

FLEX MEMBRANE INTERNATIONAL 762 HYLOAD INC. 774<br />

Bethelem Drive<br />

9976 Rittman Road<br />

Morgan<strong>to</strong>wn, PA 19543 Wadsworth, OH 44281<br />

610/286-7788 800/457-4056<br />

FAX: 610/286-7786 FAX: 330/336-5512<br />

E-mail: flexroof@compuserv.com<br />

E-mail:<br />

Web: www.flexmembranes.com<br />

Web:<br />

GAF MATERIALS CORP. 762 ICA, INC 834<br />

1361 Alps Road P. O. Box 679<br />

Wayne, NJ 07470 Warring<strong>to</strong>n, PA 18976<br />

973/628-3000 800/352-7002<br />

FAX: 973/628-3451 FAX: 215/918-8090<br />

E-mail:<br />

E-mail: hedges1@aol.com<br />

Web: gaf.com<br />

Web:<br />

GARLAND COMPANY, INC. 833 IKO INDUSTRIES 834<br />

3800 E. 91st Street 120 Hay Street<br />

Cleveland, OH 44105 Wilming<strong>to</strong>n, DE 19809<br />

216/641-7500 302/764-3100<br />

FAX: 216/641-0633 FAX: 302/764-5852<br />

E-mail:<br />

E-mail:<br />

Web:<br />

Web: www.ikocom<br />

GENFLEX ROOFING SYSTEMS 792 INTERNATIONAL DIAMOND SYSTEMS 776<br />

See Omnova Solutions P.O. Box 351950<br />

Toledo, OH 43635<br />

419/382-0111<br />

FAX: 419/382-3275<br />

E-mail: internationaldiamond@att.net<br />

Web:<br />

731


Index <strong>to</strong> Warranties<br />

WARRANTIES<br />

INCOMPLETE<br />

INCOMPLETE<br />

WARRANTIES<br />

JOHNS MANVILLE INTERNATIONAL 778 PERFORMANCE ROOF SYSTEMS 794<br />

<strong>Roof</strong>ing Systems Group<br />

4821 Chelsea Avenue<br />

P.O. Box 5108 Kansas City, MO 64130<br />

Denver, CO 80217 816/921-0221<br />

303/978-2000 FAX: 816/921-5540<br />

FAX: 303/978-3904<br />

E-mail: prshunt@aol.com<br />

Web: www.jm.com<br />

Web:<br />

JPS ELASTOMERICS 784 POLYGLASS USA 834<br />

9 Sullivan Road 150 Lyons Drive<br />

Holyoke, MA 01040-2800 Fernley, NV 89408<br />

800/621-ROOF 702/575-6007<br />

FAX: 413/552-1198 FAX: 702/575-2314<br />

E-mail: info@stvroof.com<br />

E-mail: cus<strong>to</strong>merservice@polyglass.com<br />

Web:<br />

Web: www.polyglass.com<br />

KARNAK CORPORATION 834 PROTECTIVE COATINGS INC. 796<br />

330 Central Avenue 1602 Birchwood Avenue<br />

Clark, NJ 07066 Fort Wayne, IN 46803<br />

732/388-0300 800/992-8299<br />

FAX: 732-388-9422 FAX: 219/422-7147<br />

E-mail:<br />

E-mail:<br />

Web: www.karnakcorp.com<br />

Web:<br />

KOPPERS INDUSTRIES INC. 786 REPUBLIC POWDERED METALS 796<br />

436 Seventh Avenue 3735 Green Road<br />

Pittsburgh, PA 15219 Beachwood, OH 44122<br />

800/648-9629 800/551-7081<br />

FAX: 412/227-2002 FAX: 888/742-1759<br />

E-mail:<br />

Web: www.koppers.com<br />

E-mail:<br />

Web:<br />

MFM BUILDING PRODUCTS CORP. 834 ROOFING PRODUCTS INTERNATIONAL 798<br />

P.O. Box 340<br />

57460 Dewitt Street<br />

520 Orange Street Elkhart, IN 46517<br />

Coshoc<strong>to</strong>n, OH 43812 800/628-2957 or 219/293-9096<br />

800/882-7663 FAX: 219/294-3450<br />

E-mail: mfm@coshoc<strong>to</strong>n.com<br />

E-mail:<br />

Web:<br />

Web: www.roofingproductsint. Com<br />

MULE HIDE PRODUCTS CO., INC. 790 SARNAFIL INC. 800<br />

2924 Wyetta Drive 100 Dan Road<br />

Beloit, WI 53511 Can<strong>to</strong>n, MA 02021<br />

608/365-3111 800/451-2504<br />

FAX: 608/365-7852 FAX: 781/828-5365<br />

E-mail:<br />

E-mail: webmaster@sarnafil.com<br />

Web:<br />

Web: sarnafilus.com<br />

OMNOVA SOLUTIONS, INC. 792 SEAMAN CORPORATION 800<br />

GenFlex <strong>Roof</strong>ing Systems<br />

FiberTite <strong>Roof</strong>ing Systems by Seaman<br />

1722 Indian Wood Circle, Suite A 1000 Venture Blvd.<br />

Maumee, OH Wooster, OH 44691<br />

419/891-4470 800/927-8578<br />

FAX: 419/891-4436 FAX: 800/649-2737<br />

E-mail: mike.fenner@onmova.com<br />

Web: www.fibertite.com<br />

732


Index <strong>to</strong> Warranties<br />

WARRANTIES<br />

INCOMPLETE<br />

INCOMPLETE<br />

WARRANTIES<br />

SIPLAST INC. 804 TEXSA, S.A. 834<br />

1000 E. Rochelle Blvd. Poligono Can Pelegri<br />

Irving, TX 75063<br />

San Adnreu de la Barca, Spain<br />

800/922-8800 34-3-6820770<br />

FAX: 469/995-2205 FAX: 34-3-6820752<br />

E-mail:<br />

E-mail:<br />

Web: www.siplast.com<br />

Web:<br />

SOPREMA, INC. 806 TREMCO INC. 814<br />

310 Quadral Drive 3735 Green Road<br />

Wadsworth, OH 44281 P.O. Box 228069<br />

330/334-0066 or 800/356-3521 Beachwood, OH 44122-8069<br />

FAX: 330/334-4289 216/292-5000<br />

E-mail: FAX: 216/292-5629<br />

Web:<br />

Web: www.tremcoroofing.com<br />

SOUTHWESTERN PETROLEUM CORP. 806 U.S. INTEC INC. 816<br />

534 North Main Street, P.O. Box 961005 1361 Alps Road<br />

Ft. Worth, TX 76161-0005 Wayne, NJ 07470<br />

817/332-2336 or 800/877-9372 800/624-6832<br />

FAX: 817/877-4047<br />

FAX:<br />

E-mail: swepcousa.com<br />

E-mail:<br />

Web:<br />

Web:<br />

TAMKO ROOFING PRODUCTS, INC. 808 VERSICO INC. 822<br />

220 W. 4th St., P.O. Box 1404 3485 Fortuna Drive<br />

Joplin, MO 64802 Akron, OH 44312<br />

417/624-6644 330/644-6700 or 800/992-7663<br />

FAX: 417/624-2340 FAX: 330/644-2613<br />

E-mail: info@tamko.com<br />

E-mail:<br />

Web: www.tamko.com<br />

TEXAS REFINERY CORP. 812 W.P. HICKMAN SYSTEMS 824<br />

One Refinery Place, P.O. Box 711<br />

30700 Solon Industrial Parkway<br />

Ft. Worth, TX 76101 Solon, OH 44139<br />

817/332-1161 440/248-7760<br />

FAX: 817/332-2340 FAX: 440/248-6524<br />

E-mail:<br />

Web: www.texasrefinery.com<br />

E-mail: wphickman@wphickman.com<br />

Web: www.wphickman.comj<br />

733


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity American Lubricants Company The Barrett Company, Inc. The Barrett Company, Inc.<br />

2 Title, original publication Tiffany Division Limited Material Warranty; November 1, 1989; Barrett Company Ram-Tough Elas<strong>to</strong>meric Built Up <strong>Roof</strong> Five Year Barrett Protected Membrane <strong>Roof</strong> Limited Warranty; 1984; 1984<br />

date, and identifying symbol, 10/89 Material Limited Warranty; 1986; DT 1249<br />

if any<br />

3 Product, specification, or Tiffany Modified Bitumen KLB-100-2F KLB-100-1MBKLB-100-2M, KLB-100-3F, Ram-Tough TM-500; Ram-Tough KLB Specifications KLB 3-F;<br />

system covered KLB-100-2MBKLB-100-3M, KLB-100-4FKLB-100-4M, K-312-2 KLB 3P; KLB 3-M; KLB 4PG; KLB 4F; KLB 4P; KLB 4M; KLB<br />

FK-312-3, FK-312-4 F<br />

4HS<br />

4 Scope of coverage Material only; Tiffany Division warrants its products against leaks Material only; Barrett warrants that the Ram Tough KLB Material and workmanship; Barrett warrants that its Barrett<br />

when properly applied <strong>to</strong> all structures subject <strong>to</strong> normal usage. elas<strong>to</strong>meric built-up roofing components sold by Barrett will be free Ram-Tough <strong>Roof</strong> Membrane will remain in a watertight<br />

Tiffany does not warrant the application of the product. Appli- from manufacturing defects at the time of delivery <strong>to</strong> the original condition and will not fail <strong>to</strong> function due <strong>to</strong> workmanship or<br />

cation is solely the responsibility of the purchaser. purchaser and that the KLB component materials will not defective product<br />

prematurely deteriorate <strong>to</strong> the point of failure because of<br />

weathering, if properly installed, maintained and used for the<br />

purpose Barrett intended, in accordance with Barrett published<br />

specifications in effect at the time of sale.<br />

5 Length of coverage 5 years: uncoated; 10 years: if coated at original installation with 5 years 10 and 20 years<br />

Silver-Bright Liquid-Aluminum <strong>Roof</strong> Coating, Tiff-A-Lume,<br />

granules or gravel and re-coated after five years; 15 years: see<br />

conditions for renewal or extension.<br />

6 Nature of remedy If leak occurs within the warranty coverage, American Lubricants If the Barrett-supplied membrane components or bitumen Barrett will make or cause <strong>to</strong> be made such repairs and<br />

will furnish, freight collect, sufficient additional materials of evidences manufacturing defects, Barrett will, at its option, repair maintenance necessary <strong>to</strong> enable the Ram-Tough <strong>Roof</strong><br />

Tiffany's manufacture <strong>to</strong> make necessary repairs for the duration or replace defective material at original FOB point. If the Barrett Membrane <strong>to</strong> perform as warranted, except for the removal and<br />

of the warranty. membrane components show premature deterioration, Barrett will, replacement of any materials covering the waterproof<br />

at its option, provide repair material for original membrane or will membrane<br />

provide credit <strong>to</strong> be applied <strong>to</strong>wards the purchase of new<br />

membrane components at the then current prices for the<br />

membrane.<br />

7 Monetary limitations Amount of adjustment material provided by American Lubricants Barrett's maximum liability shall be for the full value of the original Barrett's repair obligations over the life of the warranty are<br />

will in no case exceed the amount on the original purchase. Barrett supplied material components”only purchase price. In case limited <strong>to</strong> the owner's original cost of the Barrett Ram-Tough<br />

of premature deterioration, maximum value allowed as credit shall <strong>Roof</strong> Membrane.<br />

not exceed the original Barrett supplied components purchase<br />

price.<br />

8 Notification requirements None stated. None Written notification within 30 days of any failure covered by the<br />

warranty.<br />

9 Exclusive or additional Excludes UCC warranties Barrett makes no other warranty or guarantee and is in lieu of all Excludes UCC warranties<br />

remedy<br />

other obligations or liability; excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (no provision) Barrett shall have sole and exclusive right of determination of Neutral (no provision)<br />

applicability<br />

warranty applicability.<br />

12 Specific exclusions from 1, 2, 3, 4, 6, 11, 13, 17, 18, 19, 20 19 1, 2, 4, 6, 7, 8, 12, 16<br />

coverage (see Item 12 in<br />

Introduction)<br />

13 Wind coverage/exclusions No coverage for damage caused by wind No coverage for damage caused by wind.<br />

14 Specific conditions <strong>to</strong> make C, R I, O (See Special Features/Conditions.) B, C, H, R<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

Warranty excludes high winds, gales, hurricanes, and<br />

<strong>to</strong>rnadoes. [Barrett indicates that warranty covers roof damage<br />

from wind speeds up <strong>to</strong> 72 miles per hour.]<br />

734


15 Cost <strong>to</strong> obtain None None $5.00/square<br />

16 Minimum charge None None $500<br />

17 Ineligible structure or Cold-s<strong>to</strong>rage buildings, heated tanks, roofs without positive Unusual or unique applications may require specification Unusual installations are subject <strong>to</strong> technical review and<br />

building use drainage, Double T or prestressed T prefabricated concrete; modifications or other special considerations. approval.<br />

private residences.<br />

18 Pre-construction notice and Contrac<strong>to</strong>r required <strong>to</strong> submit roof record and signed warranty Contrac<strong>to</strong>r must file Barrett pre-construction form and intent <strong>to</strong> Contrac<strong>to</strong>r must submit request form with pertinent information<br />

approval requirements form. warrant application with Barrett prior <strong>to</strong> commencement of prior <strong>to</strong> job start.<br />

installation.<br />

19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy No manufacturer inspections; contrac<strong>to</strong>r makes prejob inspection Barrett makes on-site inspections prior <strong>to</strong>, during, and after Barrett technical representative makes on-site inspections prior,<br />

at his discretion. completion, as well as two years after issuance of warranty, as during, and after application, as well as two years after<br />

required or deemed necessary; no charge.<br />

completion depending on job conditions; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation None; material-only warranty Although this is a material only warranty, contrac<strong>to</strong>r is obligated <strong>to</strong> Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

obligation make repairs <strong>to</strong> all workman ship deficiencies for two years deficiencies for two years.<br />

22 Backed by named insurance No; American Lubricants Company indicates that it does not carry No; Barrett indicates that it carries $1-million-per-occurrence Surety not named on warranty; Barrett indicates it has insurance<br />

or surety insurance covering its warranty obligations. products liability insurance coverage of $1 million per occurrence.<br />

23 Issuing entity manufactures American Lubricants Company manufactures and sells product. Barrett manufactures some, but not all, components and sells the Barrett manufactures and sells some products and only sells<br />

and/or sells products products as a complete system. some products<br />

24 Conditions for renewal or 15-year warranty is in effect providing Silver Bright Aluminum <strong>Roof</strong> No renewal provision No renewal provision<br />

extension<br />

Coating is applied 30 days after installation and at 5-year intervals<br />

thereafter.<br />

25 Assignability No restrictions stated. No restrictions stated. Not assignable<br />

26 Special features/condition If purchaser does not accept delivery of the products supplied by<br />

Barrett for the purpose of work indicated, the products are <strong>to</strong> be<br />

returned forth with, unopened. Should the owner fail <strong>to</strong> properly<br />

execute and return a signed copy of warranty within 90 days of<br />

issuance, warranty shall be null and void in its entirety and any<br />

products sold shall become a materials-only sale without any<br />

warranty or guarantee as expressly provided for on Barrett<br />

invoices and terms of sale.<br />

27 Executed by owner Yes Yes Yes<br />

735


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity The Barrett Company, Inc. The Barrett Company, Inc. The Barrett Company, Inc.<br />

2 Title, original publication Barrett Company Ram-Tough Elas<strong>to</strong>meric Built-up <strong>Roof</strong> Barrett Company Ram-Tough Elas<strong>to</strong>meric Built-Up <strong>Roof</strong> Barrett Company Ram-Tough Platinum System Warranty;<br />

date, and identifying Limited Warranty; 1986; DT 1247 Material Components Ten Year Limited Warranty; 1986; DT 1986; DT 1246<br />

symbol, if any 1248<br />

3 Product, specification, or KLB-100-1PG, KLB-100-2FKLB-100-2MB, KLB-100- KLB-100-1 PG, KLB-100-2 PG, KLB-100-3 PG, KLB-100-4 KLB-100-3PG-PMR, K-312-3P-PMR, KLB-100-4PG--<br />

system covered -2PGKLB-100-3FK-312-2F, KLB-100-3PGKLB-100-4F PG, KLB-100-2P, KLB-100-3 P,KLB-100-4 P, K-312-2 P, PMRK-312-4P-PMR, KLB-100-3P-PMRK-312-4F-PMR,<br />

K-312-3F, KLB-100-4PGKLB-100-2MK-312-4F, KLB-100-2- K-312-3 P, K-312-4 P KLB-100-4P-PMR, KLB-100-4F-PMR<br />

PKLB-100-3MK-312-2P, KLB-100-3PKLB-100-4MK-312-3P,<br />

KLB-100-4PKLB-100-1MBK-312-4P<br />

4 Scope of coverage Material and workmanship; Barrett warrants that the Barrett Material only; Barrett warrants that the Ram-Tough KLB Material and workmanship; Barrett warrants that the Barrett<br />

Ram-Tough Membrane Components will remain in a elas<strong>to</strong>meric built-up roofing components sold by Barrett will be Ram-Tough Membrane Components will remain in a<br />

watertight condition. free from manufacturing defects at the time of delivery <strong>to</strong> the watertight condition and that the Foamular extruded<br />

original purchaser and that the KLB component materials will polystyrene insulation material will retain at least 80 percent of<br />

not prematurely deteriorate <strong>to</strong> the point of failure because of its thermal resistance and that the ballast will remain on the<br />

weathering, if properly installed, maintained, and used for the roof.<br />

purpose Barrett intended, in accordance with Barrett published<br />

specifications in effect at the time of sale.<br />

5 Length of coverage 5, 8, 10, 12, 15, 20, or 25 years, depending on specification 10 years 10, 15, 20, or 25 years, depending upon specification used<br />

used<br />

6 Nature of remedy In the event of failure of the product <strong>to</strong> function as warranted, If the Barrett-supplied membrane components or bitumen In the event of failure of the product <strong>to</strong> function as warranted,<br />

whether caused by workmanship or defective product, Barrett evidences manufacturing defects, Barrett will, at its option, Barrett will make or cause <strong>to</strong> be made such repairs and<br />

will make or cause <strong>to</strong> be made such repairs and maintenance repair or replace defective material at original F.O.B. point. If maintenance necessary <strong>to</strong> enable the product <strong>to</strong> perform as<br />

necessary <strong>to</strong> enable the product <strong>to</strong> perform as warranted, ex- the Barrett membrane components show premature warranted, except for the removal and replacement of any<br />

cept for the removal and replacement of any materials deterioration, Barrett will, at its option, provide repair material materials covering the system.<br />

covering the system<br />

for original membrane or will provide credit <strong>to</strong> be applied<br />

<strong>to</strong>wards the purchase of new membrane components at the<br />

then current prices for the membrane<br />

7 Monetary limitations Barrett's repair obligations over the life of the warranty are For the first five years from date of completion, Barrett's Barrett's repair obligations over the life of this warranty are<br />

limited <strong>to</strong> the owner's original cost of product. maximum liability shall be for the full value of the original limited <strong>to</strong> the owner's original cost of the product.<br />

Barrett-supplied material components’ only purchase price.<br />

Thereafter, Barrett's liability shall be reduced by 20 percent of<br />

the original warranty value each successive year until warranty<br />

expiration. In the case of premature deterioration, the<br />

maximum value allowed for credit shall not exceed the original<br />

purchase price.<br />

8 Notification requirements Prompt notification and confirmation, in writing, sent by None Written notification within 30 days following any failure of the<br />

registered or certified mail of any failure of the product within<br />

product covered by the warranty.<br />

30 days following such failure.<br />

9 Exclusive or additional Owner's sole and exclusive remedy; Barrett not liable or Barrett makes no other warranty or guarantee and is in lieu of Owner's sole and exclusive remedy; Barrett not liable or<br />

remedy obligated for any loss or damage based on breach of warranty all other obligations or liability; excludes UCC warranties obligated for any loss or damage based on breach of warranty<br />

or negligence; excludes UCC warranties<br />

or negligence; excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Barrett shall have the sole and exclusive right of good faith Barrett shall have sole and exclusive right of determination of Barrett shall have the sole and exclusive right of good faith<br />

applicability determination of warranty applicability. warranty applicability. determination of warranty applicability.<br />

12 Specific exclusions from 1, 2, 3, 4, 6, 7, 8, 12, 16, 18 19 1, 2, 3, 4, 6, 7, 8, 12, 16, 18<br />

coverage (see Item 12 in<br />

Introduction)<br />

13 Wind coverage/exclusions Warranty excludes high winds, gales, hurricanes, and Warranty covers roof damage caused by wind speeds up <strong>to</strong> Warranty excludes gales, winds<strong>to</strong>rms with gust wind speeds in<br />

<strong>to</strong>rnadoes. [Barrett indicates that coverage of wind speeds is 72 miles per hour. excess of 70 mph, hurricanes, and <strong>to</strong>rnadoes. [Barrett<br />

up <strong>to</strong> 72 miles per hour.]<br />

indicates that warranty covers roof damage resulting from<br />

wind speeds up <strong>to</strong> 70 miles per hour.]<br />

736


14 Specific conditions <strong>to</strong><br />

make the warranty<br />

ineffective or null and void<br />

(see Item 14 in<br />

Introduction)<br />

B, C, H, I, R I, O (See Special Features/Conditions.) B, C, H, I, R<br />

15 Cost <strong>to</strong> obtain $5.00/square $2.00/square $10.00/square<br />

16 Minimum charge $500 $250 $500<br />

17 Ineligible structure or<br />

building use<br />

Unusual or unique applications may require specification Unusual or unique applications may require specification Unusual or unique applications may require specification<br />

modifications or other special considerations. modifications or other special considerations modifications or other special considerations<br />

18 Pre-construction notice<br />

and approval requirements<br />

19 Approved, authorized, or<br />

licensed requirements<br />

Contrac<strong>to</strong>r must file Barrett pre-construction form and intent <strong>to</strong> Contrac<strong>to</strong>r must file Barrett pre-construction form and intent <strong>to</strong> Contrac<strong>to</strong>r must file Barrett pre-construction form and intent <strong>to</strong><br />

warrant application with Barrett prior <strong>to</strong> commencement of warrant application with Barrett prior <strong>to</strong> commencement of warrant application with Barrett prior <strong>to</strong> commencement of<br />

installation installation. installation<br />

Yes Yes Yes<br />

20 Job inspection policy Barrett makes on-site job inspections prior <strong>to</strong>, during and after Barrett makes on-site inspections prior <strong>to</strong>, during and after Barrett makes on-site job inspections prior <strong>to</strong>, during, and after<br />

completion, as well as two years after issuance of warranty as completion, as well as two years after issuance of warranty as completion, as well as two years after issuance of warranty, as<br />

required or deemed necessary; no charge. required or deemed necessary; no charge. required or deemed necessary; no charge.<br />

21 Contrac<strong>to</strong>r’s postinstallation<br />

obligation<br />

22 Backed by named<br />

insurance or surety<br />

23 Issuing entity<br />

manufactures and/or sells<br />

products<br />

24 Conditions for renewal or<br />

extension<br />

Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship Although this is a material only warranty, contrac<strong>to</strong>r is Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> all workmanship<br />

deficiencies for two years. obligated <strong>to</strong> make repairs <strong>to</strong> all workmanship deficiencies for deficiencies for two years.<br />

two years.<br />

No; Barrett indicates that it carries $1-million-per-occurrence No; Barrett indicates it carries $1-million-per-occurrence No; Barrett indicates that it carries $1-million-per-occurrence<br />

products liability insurance. products liability insurance products liability insurance<br />

Barrett manufactures some, but not all, components and sells Barrett manufactures some, but not all, components and sells Barrett manufactures some, but not all, components and sells<br />

the products as a complete system the products as a complete system. the products as a complete system<br />

No renewable provision No renewal provision No renewal provision<br />

25 Assignability Not assignable No restrictions stated Not assignable<br />

26 Special features/condition No representative of Barrett has authority <strong>to</strong> make any If purchaser does not accept delivery of the products supplied No representative of Barrett has authority <strong>to</strong> make any<br />

representation or promises except as stated on warranty. by Barrett for the purpose of work indicated, the products are representation or promises except as stated on warranty.<br />

Should the owner fail <strong>to</strong> properly execute and return a signed <strong>to</strong> be returned forth with, unopened. Should the owner fail <strong>to</strong> Should the owner fail <strong>to</strong> properly execute and return a signed<br />

copy of warranty within 90 days of issuance, warranty shall be properly execute and return a signed copy of warranty within copy of warranty within 90 days of issuance date, the warranty<br />

null and void in its entirety and any products sold shall become 90 days of issuance, warranty shall be null and void in its shall be null and void in its entirety and any products sold shall<br />

a materials-only sale without warranty or guarantee as entirety and any products sold become a materials-only sale become a materials-only sale without warranty or guarantee<br />

expressly provided for on Barrett invoices and terms of sale. without any warranty or guarantee as expressly provided for as expressly provided for on Barrett Invoices and Terms of<br />

on Barrett invoices and terms of sale<br />

Sale<br />

27 Executed by owner Yes Yes Yes<br />

737


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Bitec, Inc. Bitec, Inc. Bitec, Inc.<br />

2 Title, original publication Limited Ten-Year Material Warranty; June 1986; (F-203-1/89) limited Insured <strong>Roof</strong>ing Warranty; June 1987 "Mineral Design Limited Warranty"; January 1997; Form MDW<br />

date, and identifying - 12/96<br />

symbol, if any<br />

3 Product, specification, or All Bitec modified bitumen membranes All Bitec modified bitumen membranes Mineral Design MDA or MD5<br />

system covered<br />

4 Scope of coverage Material only; Bitec, Inc. warrants that the manufactured modified Material only, first two years; material and workmanship for Material only; Bitec warrants that the Mineral Design membrane<br />

bitumen waterproofing roofing product, at the time of installation, balance of warranty. Bitec warrants that the roofing installation will will be free from manufacturing defects which result in leaks.<br />

conforms <strong>to</strong> Bitec's published specifications, provided that the be free of defects in material and workmanship that cause it <strong>to</strong> Warranty covers the Bitec Mineral Design membrane only when<br />

membrane has been s<strong>to</strong>red, handled, and that the installation leak. During the first two years, Bitec will be responsible only for installed on slope of 3:12 or greater.<br />

meets or exceeds the published use, and is installed in<br />

defects in material only. During remaining years, Bitec will pay cost<br />

accordance with governing industry standards, the Bitec product <strong>to</strong> repair leaks caused by ordinary wear and tear. (See Special<br />

will be free of manufacturing defects and will remain free. Features/Conditions.)<br />

5 Length of coverage 10 years 10 years: APS4T.1, APS4T.2, APM4T.1, APM4T.2, SPM4.5T.1, 25 years<br />

SPM4.5T.2, SPM3.5H.1, SPM3.5H.2, SPM4H.1, SPM4H.2,<br />

SPS3H.1, SPS3H.2, SFM3.5H.1, SFM3.5H.2, SFM3.5HFR.1,<br />

SFM3.5HFR.2; 15 years: APS4T.1.15, APS4T.2.15, APM4T.1.15,<br />

APM4T.2.15, SPM4.5T.1.15, SPM4.5T.2.15, SPM3.5H.1.15,<br />

SPM3.5H.2.15, SPM4H.1.15, SPM4H.2.15, SPS3H.1.15,<br />

SPS3H.2.15, SFM3.5H.1.15, SFM3.5H.2.15, SFM3.5HFR.1.15,<br />

SFM3.5HFR.2.15; 20 years: APS4T.1.20, APS4T.2.20,<br />

APM4T.1.20, APM4T.2.20, SPM4.5T.1.20, SPM4.5T.2.20, SPM3-<br />

.5H.1.20, SPM3.5H.2.20, SPM4H.1.20, SPM4H.2.20,<br />

SPM3H.1.20, SPS3H.2.20, SFM3.5H.1.20, SFM3.5H.2.20,<br />

SFM3.5HFR.1.20, SFM3.5HFR.2.20<br />

6 Nature of remedy If manufacturing defects cause the membrane <strong>to</strong> lose its After the first two years, Bitec will pay the cost of repairs <strong>to</strong> Bitec will make repairs or cause repairs <strong>to</strong> be made or will<br />

watertight integrity, Bitec, at its sole option, will refund <strong>to</strong> the correct roof water leaks that are caused by ordinary wear and replace the Mineral Design membrane (exclusive of all other<br />

owner a portion of the original purchase cost of the membrane tear. roofing components) as required <strong>to</strong> prevent leaks resulting<br />

or replace a portion of the membrane.<br />

directly from and solely from manufacturing defects. Extent of<br />

repair or replacement is at sole discretion of Bitec.<br />

7 Monetary limitations Bitec's liability limited <strong>to</strong> refunding <strong>to</strong> owner a portion of the Bitec's obligations limited <strong>to</strong> the amount of the original cost of Bitec's maximum liability is limited <strong>to</strong> the original cost of the<br />

membrane's original cost, or replacing a portion of the<br />

membrane according <strong>to</strong> a pro-rated scheduled, reduced 10<br />

percent per year, ranging from 100% in years 1 and 2 <strong>to</strong> 10<br />

percent in year 10.<br />

labor and material for installation of the defective membrane. Mineral Design membrane when purchased, and the<br />

reasonable repair or replacement cost of the membrane. After<br />

the first year, Bitec's maximum liability is the original cost of<br />

the Mineral Design membrane reduced by 4% per year.<br />

8 Notification requirements Notification of any manufacturing defect must be submitted <strong>to</strong> Claims must be directed <strong>to</strong> Bitec, Inc., P.O. Box 497, Owner must notify Bitec by certified mail at P.O. Box 497,<br />

Bitec's general offices within five days after discovery of any Morril<strong>to</strong>n, AR 72110, must be received within 72 hours of the Morril<strong>to</strong>n, AR, 72110 within 30 days of the alleged discovery of<br />

such defect and include certificate number. (See Special Fea- original occurrence, and must be confirmed in writing and leaks allegedly <strong>to</strong> have been caused by manufacturing<br />

tures/Conditions.) received by Bitec within ten days of the occurrence. defects. (See Special Features/Conditions)<br />

9 Exclusive or additional Owner's sole and exclusive remedy. Owner shall not be Owner's sole and exclusive right and remedy and Bitec, Inc.'s Warranty is expressly in lieu of any other obligations,<br />

remedy entitled <strong>to</strong> additional remedies; owner expressly waives any sole obligation for any failure of the roofing installation or warranties and guarantees, or liability on the part of Bitec;<br />

and all other claims for damages, being direct or indirect, material; excludes UCC warranties. excludes UCC warranties.<br />

consequential or incidental, including but not expressly limited<br />

<strong>to</strong> the following: property damage, personal injury, dam-age <strong>to</strong><br />

the owner or third parties, and/or loss of business or profit;<br />

excludes UCC warranties<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (no provision) Neutral (no provision) Bitec's determination<br />

applicability<br />

738


12 Specific exclusions from 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 (including ionized 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 (including ionized 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 (including ionized<br />

coverage (see Item 12 in radiation or contamination from any hazardous substance or radiation or contamination), 15, 16, 23. Warranty also radiation or contamination from any hazardous substance or<br />

Introduction) waste), 15, 16, 23. Warranty also specifically excludes specifically excludes damage caused by food, birds, vermin, waste<br />

damage caused by food.<br />

rodents, insects, or any other animal or pest.<br />

13 Wind coverage/exclusions No coverage for damage caused by wind No coverage for damage caused by wind Warranty covers wind speeds up <strong>to</strong> 60 mph for five years after<br />

initial application if the Mineral Design membrane has been<br />

installed in accordance with published installation<br />

requirements and leaks occur. Warranty excludes gales,<br />

winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes.<br />

14 Specific conditions <strong>to</strong> I, L B, C I, L<br />

make the warranty<br />

ineffective or null and void<br />

(see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain None 10 years: no charge for coated membrane; $3.00/square for None<br />

uncoated membranes; 15 years: $4.00/square; 20 years:<br />

$5.00/square<br />

16 Minimum charge None 10 years: $300; 15 years: $400; 20 years: $500<br />

17 Ineligible structure or <strong>Roof</strong>s installed over cold s<strong>to</strong>rage or freezer compartments Cold s<strong>to</strong>rage, freezer compartments, residences, apartment <strong>Roof</strong> installed over cold s<strong>to</strong>rage or freezer compartments.<br />

building use<br />

buildings, and condominiums<br />

18 Pre-construction notice None required Contrac<strong>to</strong>r required <strong>to</strong> give notice and obtain approval at least None required<br />

and approval requirements<br />

14 days before project is started.<br />

19 Approved, authorized, or No Yes No<br />

licensed requirements<br />

20 Job inspection policy No on-site inspections Bitec field technical representative makes on-site job No on-site inspections.<br />

inspections prior <strong>to</strong>, during, and after completion prior <strong>to</strong><br />

issuance of warranty; no charge. Per diem cost for extra<br />

inspection.<br />

21 Contrac<strong>to</strong>r’s post- None Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship None; material-only warranty<br />

installation obligation<br />

deficiencies for two years.<br />

22 Backed by named No; Bitec indicates that it does not carry insurance covering its No; Bitec indicates that it does not carry insurance covering its No; Bitec indicates that it does not carry insurance covering its<br />

insurance or surety warranty obligations. warranty obligations. warranty obligations.<br />

23 Issuing entity Bitec, Inc. manufactures and sells product Bitec, Inc. manufactures and sells product. Bitec manufactures and sells the product<br />

manufactures and/or sells<br />

products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision.<br />

extension<br />

25 Assignability Warranty is transferable or assignable only with the prior Not assignable Non-transferable. Warranty solely benefits the first consumer,<br />

written approval of Bitec's manager of technical services, and<br />

purchaser or owner of Bitec Mineral Design membrane; it<br />

payment of applicable transfer fee, which includes inspection<br />

cannot be transferred in any form <strong>to</strong> anyone.<br />

fee and travel expenses.<br />

26 Special features/condition For warranty <strong>to</strong> be validated, registration form must be completed Owner agrees that the Bitec authorized roofing contrac<strong>to</strong>r shall be Claims require proof of purchase of the Mineral Design<br />

and mailed <strong>to</strong> Bitec's offices, P.O. Box 497, Morril<strong>to</strong>n, AR 72110, solely responsible for any and all costs <strong>to</strong> repair or correct any and membrane. Owner must provide Bitec with a receipt which can<br />

within 30 days after job completion. all water leaks caused by defective workmanship or installation for be traced <strong>to</strong> a Bitec distribu<strong>to</strong>r who sold the Mineral Design<br />

two years, and Bitec shall be held harmless against any and all<br />

claims arising from workmanship or installation during the first two<br />

years.<br />

membrane.<br />

Bitec has ninety days after receipt of notification <strong>to</strong> make, or<br />

cause <strong>to</strong> be made repairs or replacements covered under<br />

warranty. Prior <strong>to</strong> expiration of the ninety day period, Bitec will not<br />

be liable for any cost of repair or replacement unless Bitec has<br />

given written approval of the repair or replacement of Mineral<br />

Design membrane.<br />

Warranty may not be changed or modified. No one, including any<br />

representative or employee of Bitec has the authority <strong>to</strong> assume<br />

any additional liability for Bitec in connection with Mineral Design<br />

membranes.<br />

27 Executed by owner Owner signs Bitec registration form. No Warranty registration card must be completed and sent <strong>to</strong> Bitec<br />

within 10 days of membrane installation<br />

739


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identit of issuing entity Bondcote Corp. Carlisle SynTec Incorporated Carlisle SynTec Incorporated<br />

2 Title, original publication “BondCote <strong>Roof</strong>ing Systems Standard Warranty”; Feb. 1, Carlisle Golden Seal Total <strong>Roof</strong>ing System Warranty;” WA- “Carlisle Membrane <strong>Roof</strong>ing System Warranty;” WA-F0002<br />

date, and identifying 1993 F0001 (1/99) (1/99<br />

symbol, if any<br />

3 Product, specification, or BondCote Single Ply <strong>Roof</strong>ing Systems Sure-Seal EPDM, Brite-Ply EPDM, Fleeceback EPDM, Sure-Weld Sure-Seal EPDM, Brite-Ply EPDM, Fleeceback EPDM, Suresystem<br />

covered TPO <strong>Roof</strong>ing Systems Weld TPO <strong>Roof</strong>ing Systems<br />

4 Scope of coverage Material and workmanship; BondCote <strong>Roof</strong>ing Systems will repair Material and workmanship; Carlisle warrants <strong>to</strong> repair leaks in the Material and workmanship; Carlisle warrants <strong>to</strong> repair leaks in<br />

leaks caused by defects in the roofing system manufactured or Carlisle Golden Seal Total <strong>Roof</strong>ing System caused by a defect in the Carlisle membrane roofing system caused by a defect in the<br />

supplied by it and installed by an authorized BondCote deal- the Carlisle Total <strong>Roof</strong>ing System’s materials or workmanship of Carlisle membrane roofing systems’s materials or workmanship<br />

er/installer. Carlisle-authorized roofing applica<strong>to</strong>r in installing the Total <strong>Roof</strong>ing of Carlisle authorized applica<strong>to</strong>r in installing the membrane<br />

System. Carlisle Total <strong>Roof</strong>ing System is defined as Carlisle system. Carlisle roofing system is defined as Carlisle<br />

membrane, flashings, counter flashings, adhesives and sealants, membrane, flashings, adhesives and sealants, and any other<br />

insulation, recovery board, fasteners, fastener plates, fastening Carlisle-brand products utilized in installation.<br />

bars, metal edging, metal termination bars, and any other Carlislebrand<br />

products utilized in installation<br />

5 Length of coverage 10 years; 15 years, only for new construction or tear-off applica- 10 years: Brite-Ply and Brite-Ply Fleeceback 5 <strong>to</strong> 10 years<br />

tions using certain insulations<br />

10 or 15 years: all other systems<br />

6 Nature of remedy BondCote <strong>Roof</strong>ing Systems will provide owner with repair <strong>to</strong> Carlisle will repair leaks in the Carlisle Golden Seal Total <strong>Roof</strong>ing Carlisle will repair leaks in the Carlisle membrane system<br />

correct any leaks caused by defects in the manufacture or System.<br />

installation of roofing materials supplied by BondCote <strong>Roof</strong>ing<br />

Systems.<br />

7 Monetary limitations BondCote's cost not <strong>to</strong> exceed the owner's original installed cost None stated None stated.<br />

of materials supplied by BondCote <strong>Roof</strong>ing Systems.<br />

8 Notification requirements Written notification <strong>to</strong> BondCote <strong>Roof</strong>ing Systems, 4090 Pepperell Written notice within 30 days of discovery of any leak in the Written notice within 30 days of discovery of any leak in the Carlisle<br />

Way, Dublin, VA 24084, within 30 days after leaks are discovered Carlisle Total <strong>Roof</strong>ing System <strong>to</strong> Carlisle’s Warranty Services membrane system <strong>to</strong> Carlisle's Warranty Services, P.O. Box 7000,<br />

or should have been discovered Department, P.O. Box 7000, Carlisle, PA 17013 Carlisle, PA 17013<br />

9 Exclusive or additional Warranty is expressly agreed <strong>to</strong> be an exclusive warranty; Owner’s remedies and Carlisle’s liability limited <strong>to</strong> Carlisle’s repair Owner’s remedies and Carlisle’s liability limited <strong>to</strong> Carlisle’s<br />

remedy warranty is in lieu of any other remedy and all other warranties of leaks; remedy stated in warranty is owner’s sole and exclusive repair of leaks; remedy stated in warranty is owner’s sole and<br />

whether arising under contract, <strong>to</strong>rt, negligence, product liability, or remedy for failure of the Carlisle Total <strong>Roof</strong>ing System or its exclusive remedy for failure of the Carlisle roofing system or its<br />

any other action; excludes UCC warranties. components; excludes UCC warranties components; excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty BondCote's good-faith determination Carlisle's determination. (See Special Features/Conditions.) Carlisle's determination (See Special Features/Conditions.)<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 6, 8, 12, 16 1, 2, 3, 5, 7, 13, 16, 17. Warranty also specifically excludes insect 1, 2, 3, 5, 7, 13, 16, 17. Warranty also specifically excludes insect<br />

coverage (see Item 12 in infestation infestation<br />

Introduction)<br />

13 Wind coverage/exclusions Warranty excludes wind equal <strong>to</strong> or exceeding strong gale, Warranty form states it excludes winds of peak gust speeds ___ Warranty form states that it excludes a wind of peak gust speeds ___<br />

hurricanes, and <strong>to</strong>rnadoes. Warranty covers roof damage resulting mph or higher measured at 10 meters above ground, hurricanes, mph or higher measured at 10 meters above ground,@ hurricanes, and<br />

from wind speeds up <strong>to</strong> 46 miles per hour. and <strong>to</strong>rnadoes. Carlisle indicates that warranty covers roof <strong>to</strong>rnadoes. Carlisle indicates that 55 is inserted when warranty is issued<br />

damage resulting from wind speeds up <strong>to</strong> 55 mph. Carlisle so that warranty covers roof damage resulting from wind speeds up <strong>to</strong> 55<br />

indicates that, when a request is made, warranty can be obtained mph.<br />

<strong>to</strong> cover higher speeds after a project specification and detail<br />

review.<br />

14 Specific conditions <strong>to</strong> make C, I B, C, F (including failure of owner <strong>to</strong> comply with Carlisle’s care B, C, F (including failure of owner <strong>to</strong> comply with Carlisle's care<br />

the warranty ineffective or and maintenance information sheet) and maintenance information sheet)<br />

null and void (see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain Manufacturer charges for this warranty; however, they refused <strong>to</strong> (Carlisle declines <strong>to</strong> provide this information because it is used<br />

provide costs. Contact manufacturer directly for specific pricing for marketing purposes.)<br />

information.<br />

740


16 Minimum charge Manufacturer charges for this warranty; however, they refused <strong>to</strong> (Carlisle declines <strong>to</strong> provide this information because it is used<br />

provide costs. Contact manufacturer directly for specific pricing for marketing purposes.)<br />

information<br />

17 Ineligible structure or Single-family residential structures; however, warranty is available Single-family residential structures; however, warranty is<br />

building use for apartment homes, co-ops, condominiums, and the like. available for apartment homes, co-ops, condominiums, and the<br />

like.<br />

18 Pre-construction notice and Contrac<strong>to</strong>r must complete project approval form and forward <strong>to</strong> Carlisle must be contacted for a project specification and detail Carlisle must be contacted for a project specification and detail<br />

approval requirements BondCote <strong>Roof</strong>ing Systems for approval prior <strong>to</strong> job start. review review on projects where the building height exceeds 75 feet for<br />

Design B, 150 feet for mechanically fastened systems, and 250<br />

feet for adhered systems.<br />

19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy BondCote technical field representative makes inspections after If requested by owner or applica<strong>to</strong>r, Carlisle technical If requested by owner or applica<strong>to</strong>r, Carlisle technical<br />

completion prior <strong>to</strong> issuing warranty; BondCote will inspect prior <strong>to</strong> representative makes on-site inspections prior <strong>to</strong> and during representative makes on-site inspections prior and during<br />

and during application for “new contrac<strong>to</strong>rs” and on large or application; Carlisle makes on-site inspection after completion application; after completion prior <strong>to</strong> issuance of warranty; two<br />

difficult installations. prior <strong>to</strong> issuance of warranty; two inspections at no charge. Each inspections at no charge. Each additional inspection will cost<br />

additional inspection will cost $500 $500.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

obligation for two years. for two years. deficiencies for two years.<br />

22 Backed by named insurance No; BondCote indicates that it does not carry insurance covering No; Carlisle indicates that it does not carry insurance covering its No; Carlisle indicates that it does not carry insurance covering<br />

or surety its warranty obligations. warranty obligation. its warranty obligation<br />

23 Issuing entity manufactures BondCote <strong>Roof</strong>ing Systems manufactures and sells the product Carlisle manufactures and sells system components. Carlisle manufactures and sells system components<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision Warranty may be renewed for an additional 5 years. (Carlisle<br />

extension<br />

declined <strong>to</strong> provide further information regarding costs and<br />

procedures <strong>to</strong> renew.)<br />

25 Assignability Not assignable without written permission from BondCote <strong>Roof</strong>ing Systems Warranty not assignable by operation of law or otherwise; however,<br />

application may be made by a new building owner for reissuance of the<br />

warranty during the original warranty period. Certain procedures, including<br />

an inspection of the roofing system by a Carlisle representative, and fees<br />

may apply <strong>to</strong> any reissuance. Carlisle reserves the right, in its sole<br />

discretion, <strong>to</strong> refuse <strong>to</strong> reissue warranty.<br />

26 Special features/condition BondCote <strong>Roof</strong>ing Systems has no obligation under the warranty without Carlisle shall not be responsible for the cleanliness or discoloration of the<br />

owner's signature accepting the warranty in lieu of all other remedies and membrane system caused by environmental conditions including, but not<br />

the return of signed copy <strong>to</strong> BondCote <strong>Roof</strong>ing Systems; the extended limited <strong>to</strong>, dirt, pollutants, or biological agents. Carlisle does not warrant<br />

warranty has the same limitations as the original ten-year warranty. Owner products utilized in installation that it has not furnished and specifically<br />

shall be responsible for the cost of investigation if any leaks are determined disclaims liability, under any theory of law, arising out of installation and<br />

not <strong>to</strong> be covered under warranty.<br />

performance of, or damages sustained by or caused by, products not<br />

furnished by Carlisle. If Carlisle’s investigation after receipt of notice of leak<br />

from owner reveals that cause of leak is outside scope of warranty,<br />

investigation and repair costs are <strong>to</strong> be paid by the owner.<br />

27 Executed by owner Yes (See Special Features/Conditions.) No No<br />

Warranty is not assignable by operation of law or otherwise;<br />

however, application may be made by a new owner for<br />

reissuance of the warranty during the original warranty period.<br />

Certain procedures, including but not limited <strong>to</strong>, an inspection of<br />

the <strong>Roof</strong>ing System by a Carlisle representative, and fees may<br />

apply <strong>to</strong> any reissuance.<br />

Carlisle shall not be responsible for the cleanliness or<br />

discoloration of the Carlisle roofing system caused by<br />

environmental conditions including, but not limited <strong>to</strong>, dirt,<br />

pollutants, or biological agents. Carlisle does not warrant<br />

products utilized in installation that it has not furnished and<br />

specifically disclaims liability, under any theory of law, arising<br />

out of the products not furnished by Carlisle. If Carlisle’s<br />

investigation after receipt of notice of a leak from owner reveals<br />

that cause of leak is outside scope of warranty, investigation<br />

and repair costs are <strong>to</strong> be paid by the owner.<br />

741


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Celotex Corporation Celotex Corporation Celotex Corporation<br />

2 Title, original publication "Celo-1 Extended Coverage <strong>Roof</strong>ing Sheet Only Warranty"; "Commercial <strong>Roof</strong>ing Material Only Limited Warranty"; September 1997; Celo-1 EPDM Membrane Material Only Limited Warranty";<br />

date, and identifying symbol, September 1997; Form 1038-0587 Rev. C Form 1146-1190 Rev.D September 1997; Form 1010-0888 Rev. D<br />

if any<br />

3 Product, specification, or Celo-1 Type I, Celo-1 Type II, Celo-1 Type III, Celo-1 Type IIIR BUR Specifications: AGS-5-W-M, AGS-5-C-M, AGS-4-F-G, G/A-5-W-M, Celo-1 Type I, Celo-1 Type II, Celo-1 Type III, Celo-1 Type IIIR<br />

system covered<br />

G/A-5-C-M, G/A-4-F-G, AGS-4-W-M, AGS-4-C-M, AGS-4-F-S, G/A-4-W-M,<br />

G/A-4-C-M, G/A-4-F-S, AGS-4-W-G, AGS-4-C-G, AGS-H+4-W-M, G/A-4-W-<br />

G, G/A-4-C-G, G/A-H+4-W-M, AGS-4-W-S, AGS-4-C-S, AGS-H+3-W-M,<br />

G/A-4-W-S, G/A-4-C-S, G/A-H+3-W-M, G/A-3-W-G, AGS-5-F-M, AGS-H+3-<br />

W-S, G/A-5-F-M, G/A-H+3-W-S, G/A-3-W-M, AGS-3-C-G, AGS-H+3-W-G,<br />

G/A-3-C-G, G/A-H+3-W-G, G/A-3-W-S, AGS-4-F-M, G/A-4-F-M; Modified<br />

Bitumen Specifications: SBS-4-W-M, SBS-DP-3-F-M, APP-3-C-M, SBS-3-<br />

W-M, SBS-DP-2-F-M, APP-2-C-M, SBS-2-W-M, SBS-H+2-W-M, APP-4-C-<br />

S, SBS-DP-4-W-M, SBS-H+2-W-M, APP-3-C-S, SBS-DP-3-W-M, SBS-H+2-<br />

IV-W-M, APP-2-C-S, SBS-DP-2-W-M, SBS-DP-H+3-W-M, APP-4-F-M, SBS-<br />

4-C-M, SBS-DP-H+2-W-M, APP-3-F-M, SBS-3-C-M, SBS-2-C-M, APP-2-F-<br />

M, SBS-2-C-M, SBS-2-R-M, APP-4-F-S, SBS-DP-4-C-M, APP-4-W-M, APP-<br />

3-F-S, SBS-DP-3-C-M, APP-3-W-M, APP-2-F-S, SBS-DP-2-C-M, APP-2-W-<br />

M, APP-H+3-W-M, SBS-4-F-M, APP-4-W-S, APP-H+2-W-M, SBS-3-F-M,<br />

APP-3-W-S, APP-H+2-IV-W-M, SBS-2-F-M, APP-2-W-S, APP-H+3-W-S,<br />

SBS-DP-4-F-M, APP-4-C-M, APP-H+2-W-S, APP-H+2-IV-W-S<br />

4 Scope of coverage Material only; Celotex represents that its cured Celo-1 EPDM Material only; Celotex warrants that the Celotex roof membrane and base Material only; Celotex represents that its cured EPDM rubber<br />

roofing sheet is free from manufacturing defects and will not flashing will withstand ordinary wear and tear by the elements and will be roofing sheet is free from manufacturing defects and will not<br />

deteriorate prematurely <strong>to</strong> the point of failure due <strong>to</strong> weathering. free of manufacturing defects which affect the ability of the materials <strong>to</strong> keep deteriorate prematurely <strong>to</strong> the point of failure due <strong>to</strong> weathering.<br />

the roof watertight.<br />

5 Length of coverage 5 or 10 years beyond termination date of <strong>Roof</strong>ing System Limited 10 years: built-up roofing; 12 years: modified bitumen 10 years<br />

Warranty for Celo-1 EPDM (See Special Features/Conditions)<br />

6 Nature of remedy Celotex will provide replacement material, F.O.B., place of Celotex will provide replacement material Celotex will, at its option, provide replacement membrane,<br />

manufacture. Celotex not responsible for any labor and service<br />

F.O.B., place of manufacture, <strong>to</strong> effect repair or provide credit <strong>to</strong><br />

charges pertaining <strong>to</strong> either original or replacement product.<br />

be applied <strong>to</strong>wards the purchase of replacement membrane.<br />

Owner's sole remedy and Celotex's liability is replacement of that<br />

Celotex not responsible for any labor or service charges<br />

portion of the Celotex roof membrane or base flashing which<br />

pertaining <strong>to</strong> either original or replacement membrane.<br />

contains manufacturing defects or deterioration caused by ordinary<br />

Warranty is prorated at the rate of 1/120 for each month of<br />

wear and tear of the elements that has caused one or more leaks.<br />

service<br />

Warranty is prorated for each month of service<br />

7 Monetary limitations Celotex's maximum responsibility is the original cost of the Celotex Celotex's maximum responsibility is the original cost of the Celotex Celotex's maximum responsibility is the original cost of the<br />

membrane and flashing materials. Original purchase price of membrane and flashing materials. Celotex is not responsible for any labor Celotex membrane and flashing materials. In calculating<br />

EPDM sheet is reduced for each month of service provided by the charges Celotex's liability, the cost of the original membrane will be<br />

product<br />

reduced by the amount of usage owner has received prior <strong>to</strong> the<br />

date of the claim, at the rate of 1/120 for each month of service<br />

provided by the membrane after the date of the original<br />

purchase.<br />

8 Notification requirements Written notice within 10 days of discovery of any leaks in the Written notice within 10 days of discovery of any leaks in the roofing system Written notice within 10 days of the discovery of any leaks in the<br />

roofing system <strong>to</strong> Celotex Corporation, P.O. Box 31602, Tampa, <strong>to</strong> Celotex Corporation, P.O. Box 31602, Tampa, FL 33631. membrane <strong>to</strong> Celotex Corporation, P.O. Box 31602, Tampa, FL<br />

FL 33631. 33631.<br />

9 Exclusive or additional Celotex makes no warranties or guarantees of any kind, express Warranty is owner's sole and exclusive remedy with respect <strong>to</strong> the roofing Celotex makes no warranties or guarantees of any kind, express<br />

remedy or implied, except as stated in warranty; excludes UCC warranties system and owner waives any and all other claims, rights, proceedings, or implied, except as stated in warranty; excludes UCC<br />

actions and demands from Celotex relating <strong>to</strong> the roofing system. Warranty warranties.<br />

is in lieu of any and all other Celotex warranties; excludes UCC warranties<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Celotex’s determination Celotex's determination Celotex's determination.<br />

applicability<br />

12 Specific exclusions from 1 (including chemical or organic deposits), 2, 3, 4, 5, 6, 7, 8, 9, 11, 1 (including chemical or organic deposits), 2, 3, 4, 5, 6, 7, 8, 9, 11, 12, 15, 1 (including chemical or organic deposits), 2, 3, 4, 5, 6, 8,<br />

coverage (see Item 12 in 12, 15, 23 20, 23 9, 11, 12, 15, 19, 20, 23<br />

Introduction)<br />

742


13 Wind coverage/exclusions Warranty covers roof damage resulting from wind speeds up <strong>to</strong> 72 Warranty covers roof damage resulting from wind speeds up <strong>to</strong> 72 Warranty covers roof damage resulting from wind speeds up <strong>to</strong><br />

mph. Warranty excludes gales, hurricanes and <strong>to</strong>rnadoes. mph. Warranty excludes gales, hurricanes and <strong>to</strong>rnadoes. 72 mph. Warranty excludes gales, hurricanes and <strong>to</strong>rnadoes<br />

14 Specific conditions <strong>to</strong> make C<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

C<br />

C<br />

15 Cost <strong>to</strong> obtain 5 years: $1.00/square; 10 years: $2.00/square $100<br />

None<br />

16 Minimum charge 5 years: $100; 10 years: $200 $100 None<br />

17 Ineligible structure or building<br />

use<br />

Contact local Celotex sales office for building evaluation None None<br />

18 Pre-construction notice and<br />

approval requirements<br />

Contrac<strong>to</strong>r must fill out a Notice of Award; if accepted, notify<br />

Celotex of start date and completion<br />

None<br />

None required<br />

19 Approved, authorized, or licensed<br />

requirements<br />

Yes No Yes<br />

20 Job inspection policy Independent inspection service makes on-site inspections after No on-site inspections<br />

No on-site inspections.<br />

completion, as well as two years after issuance of warranty; no<br />

charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> materials and None; material-only warranty.<br />

None; material-only warranty<br />

obligation<br />

workmanship deficiencies for two years<br />

22 Backed by named insurance No; Celotex indicates that it does not carry insurance covering its No; Celotex indicates that it does not carry insurance covering its warranty No; Celotex indicates that it does not carry insurance covering<br />

or surety warranty obligations obligations.<br />

its warranty obligations<br />

23 Issuing entity manufactures Celotex manufactures and sells the product Celotex manufactures and sells the product.<br />

Celotex manufactures and sells the product<br />

and/or sells products<br />

24 Conditions for renewal or<br />

extension<br />

No renewal provision No renewal provision No renewal provision<br />

25 Assignability Not assignable; warranty accrues <strong>to</strong> the original owner named in the<br />

warranty and does not accrue <strong>to</strong> the benefit of any tenant, purchaser,<br />

successor, or assignee<br />

26 Special features/condition This is an extended warranty, issued and valid only with purchase of<br />

Celotex <strong>Roof</strong>ing System Limited Warranty and covers roofing sheet only<br />

after expiration of standard warranty.<br />

No representative of Celotex has authority <strong>to</strong> make any representation or<br />

promise except as stated in warranty document.<br />

Any inspection conducted by Celotex may require that adequate samples of<br />

the roofing system be taken for testing by Celotex <strong>to</strong> evaluate any claim of<br />

purported defect or deterioration. Refusal by the owner <strong>to</strong> permit removal of<br />

samples of testing constitutes a waiver of the claim.<br />

If Celotex <strong>Roof</strong>ing System Limited Warranty is terminated or canceled for<br />

reasons other than normal expiration, this <strong>Roof</strong>ing Sheet Only Limited<br />

Warranty shall be void upon such termination or cancellation<br />

Not assignable; warranty accrues <strong>to</strong> the original owner named in<br />

the warranty and does not accrue <strong>to</strong> the benefit of any tenant,<br />

purchaser, successor or assignee.<br />

Warranty only applies <strong>to</strong> Celotex materials which are installed in<br />

accordance with current Celotex specifications.<br />

No representative of Celotex has authority <strong>to</strong> make<br />

any representation or promise except as stated in warranty<br />

document.<br />

Any inspection conducted by Celotex may require that adequate<br />

samples of the roof be taken for testing by Celotex <strong>to</strong> evaluate any<br />

claim of a purported defect or deterioration. Refusal by the owner<br />

<strong>to</strong> permit removal of samples for testing constitutes a waiver of the<br />

claim.<br />

Not assignable; warranty accrues <strong>to</strong> the original owner named in<br />

the warranty and does not accrue <strong>to</strong> the benefit of any tenant,<br />

purchaser, successor, or assignee<br />

No representative of Celotex has authority <strong>to</strong> make any<br />

representation or promise except as stated in warranty<br />

document.<br />

Any inspection conducted by Celotex may require that<br />

adequate samples of the Membrane be taken for testing by<br />

Celotex <strong>to</strong> evaluate any claim of a purported defect or<br />

deterioration. Refusal by the owner <strong>to</strong> permit removal of<br />

samples for testing constitutes a waiver of the claim.<br />

27 Executed by owner No No No<br />

743


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Celotex Corporation Celotex Corporation Conklin Company, Inc.<br />

2 Title, original publication Specification Warranty"; September 1997; Form 1033-0487 Rev. B "<strong>Roof</strong>ing System Limited Warranty"; September 1997; Form 1005- Conklin Limited Materials Warranty; November 1990; 1-000-<br />

date, and identifying symbol,<br />

1092 Rev. A 141A (Code #078270B 11/96 appears on packet accompanying<br />

if any<br />

warranty documents.)<br />

3 Product, specification, or Built-Up <strong>Roof</strong>ing Specifications: AGS-5-W-M, AGS-4-C-S, AGS- Built-Up <strong>Roof</strong>ing Specifications: G/A-5-W-M, G/A-5-C-M, G/A-4-F- Hy-Crown<br />

system covered<br />

H+3-W-M, AGS-4-W-M, AGS-3-C-G, AGS-H+3-W-G, AGS-4-W-G, G, G/A-4-W-M, G/A-4-C-M, G/A-4-F-S, G/A-4-W-G, G/A-4-C-G, G/A-<br />

AGS-5-F-M, AGS-H+3-W-S, AGS-4-W-S, AGS-4-F-M, AGS-5-C-M, H+4-W-M, G/A-4-W-S, G/A-4-C-S, G/A-H+3-W-M, G/A-3-W-M, G/A-3-<br />

AGS-4-F-G, AGS-4-C-M, AGS-4-F-S, AGS -4-C-G, AGS-H+4-W-M. C-G, G/A-H+3-W-G, G/A-3-W-G, G/A-5-F-M, G/A-H+3-W-S, G/A-3-W-<br />

(All specifications require use of AGS felt.)<br />

S, G/A-4-F-M; Modified Bitumen Specifications: SBS-4-W-M, SBS-<br />

DP-3-F-M, APP-3-C-M, SBS-3-W-M, SBS-DP-2-F-M, APP-2-C-M,<br />

SBS-2-W-M, SBS-H+3-W-M, APP-4-C-S, SBS-DP-4-W-M, SBS-H+2-<br />

W-M, APP-3-C-S, SBS-DP-3-W-M, SBS-H+2-IV-W-M, APP-2-C-S,<br />

SBS-DP-2-W-M, SBS-DP-H+3-W-M, APP-4-F-M, SBS-4-C-M, SBS-<br />

DP-H+2-W-M, APP-3-F-M, SBS-3-C-M, SBS-2-C-M, APP-2-F-M, SBS-<br />

2-C-M, SBS-2-R-M, APP-4-F-S, SBS-DP-4-C-M, APP-4-W-M, APP-3-<br />

F-S, SBS-DP-3-C-M, APP-3-W-M, APP-2-F-S, SBS-DP-2-C-M, APP-2-<br />

W-M, APP-H+3-W-M, SBS-4-F-M, APP-4-W-S, APP-H+2-W-M, SBS-<br />

3-F-M, APP-3-W-S, APP-H+2-IV-W-M, SBS-2-F-M, APP-2-W-S, APP-<br />

H+3-W-S, SBS-DP-4-F-M, APP-4-C-M, APP-H+2-W-S, APP-H+2-IV-<br />

W-S; EPDM Specifications: Celo-1 Type I, Celo-1 Type II, Celo-1<br />

Type III, Celo-1 Type IIIR Membrane Insulation Assembly (MIA)<br />

4 Scope of coverage Material and workmanship; Celotex will repair any leaks in the Celotex Material and workmanship; Celotex warrants that it will repair leaks in Material only; Conklin warrants that the roof will not leak in<br />

roof membrane and base flashing caused by defects in the Celotex the Celotex roof membrane and base flashing caused by defects in the ordinary weather conditions due <strong>to</strong> any defect in product<br />

roofing materials or errors in workmanship.<br />

Celotex roofing materials or errors in workmanship.<br />

materials manufactured or sold by Conklin.<br />

5 Length of coverage 10 years: 3 ply; 15 years: 3 ply; 20 years: 4 ply 10 years: Celo-1 EPDM, Built-up <strong>Roof</strong>ing; 12 years: Modified Bitumen; 1 <strong>to</strong> 15 years<br />

15 years: Celo-1 EPDM Built-up <strong>Roof</strong>ing, Modified Bitumen; 20 years:<br />

Built-up <strong>Roof</strong>ing and Modified Bitumen<br />

6 Nature of remedy Celotex will have repairs made and will pay for such repairs. Owner's Celotex will have repairs made and will pay for such repairs. Owner's Conklin's obligation is limited <strong>to</strong> the replacement of Conklin<br />

sole remedy and Celotex's liability limited <strong>to</strong> Celotex's repair of Celotex sole remedy and Celotex's liability limited <strong>to</strong> Celotex's repair of the roofing product(s) <strong>to</strong> repair leaks.<br />

roofing materials.<br />

Celotex roof membrane and base flashing.<br />

7 Monetary limitations None stated.<br />

For built-up roofing and modified bitumen specifications, Celotex's<br />

maximum liability is limited <strong>to</strong> $100/square. For Membrane Insulation<br />

Assembly Warranty, Celotex's maximum liability is limited <strong>to</strong><br />

$130/square. For Celo-1 EPDM specifications, Celotex's maximum<br />

liability is limited <strong>to</strong> the original installed cost of Celotex membrane<br />

materials.<br />

None stated<br />

8 Notification requirements Written notice within 10 days of discovery of any leaks in the roofing Written notice within 10 days of discovery of leaks in the roofing Notification within 30 days following the discovery of<br />

system <strong>to</strong> Celotex Corporation, P.O. Box 31602, Tampa, FL 33631. system <strong>to</strong> Celotex Corporation, P.O. Box 31602, Tampa, FL 33631. circumstances giving rise <strong>to</strong> a claim <strong>to</strong> contrac<strong>to</strong>r and Conklin at<br />

551 Valley Park Drive, P. O. Box 155, Shakopee, MN 55379<br />

9 Exclusive or additional Warranty is owner's sole and exclusive remedy with respect <strong>to</strong> the Warranty is owner's sole and exclusive remedy with respect <strong>to</strong> the Warranty is given in lieu of any other warranty; excludes UCC<br />

remedy<br />

roofing system and owner waives any and all other claims, rights, roofing system and Owner waives any and all other claims, rights, warranties; warran<strong>to</strong>rs shall not be liable for any direct, indirect,<br />

proceedings, actions and demands from Celotex relating <strong>to</strong> the roofing proceedings, actions and demands from Celotex relating <strong>to</strong> the roofing incidental, consequential, special, or general damages resulting<br />

system. Warranty is in lieu of any and all other Celotex warranties; system. Warranty is in lieu of any and all other Celotex warranties;<br />

excludes UCC warranties.<br />

excludes UCC warranties.<br />

from failure of the Conklin system.<br />

10 Inclusion of consequential No<br />

No<br />

No<br />

damages<br />

11 Determination of warranty Celotex’s determination<br />

Celotex’s determination<br />

Neutral (no provision)<br />

applicability<br />

12 Specific exclusions from 1 (including chemical or organic deposits), 2, 3, 4, 5, 6, 7, 8, 9, 11, 12, 1 (including chemical or organic deposits), 2, 3, 4, 5, 6, 7, 8, 9, 11, 12, 1, 2, 3, 4, 6, 7, 14, 15, 16 19, 20, 24, 25<br />

coverage (see Item 12 in 15, 23 15, 23<br />

Introduction)<br />

13 Wind coverage/exclusions Warranty covers roof damage resulting from wind speeds up <strong>to</strong> 72 Celotex indicates warranty covers damage resulting from winds without Warranty excludes gales, winds<strong>to</strong>rms, hurricanes, and<br />

mph. Warranty excludes gales, hurricanes and <strong>to</strong>rnadoes. stating a speed. Warranty excludes gales, hurricanes and <strong>to</strong>rnadoes. <strong>to</strong>rnadoes. Conklin indicates that warranty covers roof damage<br />

resulting from wind speeds up <strong>to</strong> 43 miles per hour.<br />

744


14 Specific conditions <strong>to</strong> make C<br />

C<br />

Including notice <strong>to</strong> contrac<strong>to</strong>r (R)<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain 10 years: $10.00/square; 15 years: $12.00/square; 20 years: Celo-1<br />

1 <strong>to</strong> 10 years: no charge; 11 <strong>to</strong> 15 years: less than 10,000<br />

$15.00/square<br />

10 years: $ 5.00/square; 15 years: $10.00/square<br />

Built-Up <strong>Roof</strong>ing<br />

square feet, $200; greater than 10,000 square feet, $300<br />

10 years: $ 7.00/square; 10 years MIA: $10.00/square; 15 years: $<br />

9.00/square; 15 years MIA: $11.00/square; 20 years: $14.00/square;<br />

20 years MIA: $13.00/square<br />

Modified Bitumen<br />

12 years: $ 8.00/square; 12 years MIA: $10.00/square; 15 years: $<br />

9.00/square; 15 years MIA: $11.00/square; 20 years: $14.00/square;<br />

20 years MIA: $13.00 /square<br />

16 Minimum charge 10 years: $1,000; 15 years: $1,200; 20 years: $1,500 Celo-1<br />

10 years: $ 500; 15 years: $1,000<br />

Built-up <strong>Roof</strong>ing<br />

10 years: $ 700; 10 years MIA: $1,000; 15 years: $ 900; 15 years<br />

MIA: $1,100; 20 years: $1,400; 20 years MIA: $1,300<br />

Modified Bitumen<br />

None for 1 <strong>to</strong> 10 years; $200 for 11 <strong>to</strong> 15 years<br />

12 years: $ 800; 12 years MIA: $1,000; 15 years: $ 900; 15 years<br />

MIA: $1,100; 20 years: $1,400;<br />

20 years MIA: $1,300<br />

17 Ineligible structure or None<br />

Contact local Celotex sales office for building evaluation.<br />

None<br />

building use<br />

18 Pre-construction notice and Contrac<strong>to</strong>r must fill out Notice of Award; if accepted, notify Celotex of Contrac<strong>to</strong>r must fill out a Notice of Award; if accepted, notify Celotex of Application must be submitted within 30 days of completion of<br />

approval requirements start date and completion. start date and completion. project<br />

19 Approved, authorized, or Yes<br />

Yes<br />

Yes<br />

licensed requirements<br />

20 Job inspection policy Independent inspection service makes on-site inspections prior <strong>to</strong> Independent inspection service makes on-site inspections after No on-site inspections<br />

application and after completion prior <strong>to</strong> issuance of warranty, as well completion prior <strong>to</strong> issuance of warranty, as well as two years after<br />

as two years after issuance of warranty; no charge<br />

issuance of warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> all leaks, any defects and Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> materials and workmanship None; material-only warranty<br />

obligation<br />

workmanship deficiencies for two years.<br />

deficiencies for two years.<br />

22 Backed by named insurance No; Celotex indicates that it does not carry insurance covering its No; Celotex indicates that it does not carry insurance covering its No; Conklin indicates that it does not carry insurance covering<br />

or surety<br />

warranty obligations. warranty obligations. its warranty obligations<br />

23 Issuing entity manufactures Celotex manufactures and sells product.<br />

Celotex manufactures and sells the product<br />

Conklin sells product only<br />

and/or sells products<br />

24 Conditions for renewal or Warranty may be extended for five years at a cost of $500.<br />

No renewal provision. For Celo-1 specifications, "Celo-1 Extended No renewal provision<br />

extension<br />

Coverage <strong>Roof</strong>ing Sheet Only Warranty" for 5 or 10 year additional<br />

material-only warranty coverage<br />

25 Assignability Not assignable; warranty applies <strong>to</strong> the original owner named in the Not assignable; warranty accrues <strong>to</strong> the original owner named in the No restrictions stated<br />

warranty and cannot be transferred <strong>to</strong> or for the benefit of any tenant, warranty and does not accrue <strong>to</strong> the benefit of any tenant, purchaser,<br />

purchaser, successor, or assignee.<br />

successor, or assignee<br />

26 Special features/condition No representative of Celotex has authority <strong>to</strong> make any representation This warranty form is used for built-up roofing, modified bitumen, Celoor<br />

Warranty interpreted and governed by the laws of the state of<br />

promise except as stated in warranty document.<br />

1 EPDM, membrane insulation assembly (M.I.A.), and membrane only. Minnesota<br />

Any inspection conducted by Celotex may require that adequate At time of issuance, warranty type is designated.<br />

samples of the roofing system be taken for testing by Celotex <strong>to</strong> No representative of Celotex has authority <strong>to</strong> make any<br />

evaluate any claim of purported defect or deterioration. Refusal by the representation or promise except as stated in warranty document.<br />

owner <strong>to</strong> permit removal of samples for testing constitutes a waiver of Any inspection conducted by Celotex may require that adequate<br />

the claim<br />

samples of the roofing system be taken for testing by Celotex <strong>to</strong><br />

evaluate any claim or purported defect or deterioration. Refusal by the<br />

owner <strong>to</strong> permit removal of samples for testing constitutes a waiver of<br />

the claim.<br />

27 Executed by owner No<br />

No<br />

Yes<br />

745


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

Identity of issuing entity<br />

1 Conklin Company, Inc. Conklin Company, Inc. Danosa Caribbean, Inc.<br />

2 Title, original publication “Conklin Company Limited Joint Warranty”; Form E; November Conklin Company, Inc. Total <strong>Roof</strong> System Limited Joint Warranty; Damnosa <strong>Roof</strong>ing Membrane System Limited Warranty; 1979<br />

date, and identifying symbol, 1990; 1-00139A; (Code #078269A 07/94 appears on packet Form E; November 1990; 1-000139; (Code #078268B 01/93<br />

if any accompanying warranty documents.) appears on packet accompanying warranty documents.<br />

3 Product, specification, or system Hy-Crown. Warranty is limited exclusively <strong>to</strong> the use of approved Hy-Crown. Warranty is limited exclusively <strong>to</strong> the use of approved Esterdan RM; Glasdan AL-80, Glasdan R-36; Esterdan R-36<br />

covered Conklin Joint Warranty roofing membrane system. substrate materials overlaid with an approved Conklin roof<br />

membrane. The Conklin Total <strong>Roof</strong> System consists of Conklin<br />

roof membrane, Conklin fasteners, plates and approved<br />

boards<strong>to</strong>ck insulation, polyurethane foam, and/or Hy-Crown slip<br />

sheet.<br />

4 Scope of coverage Material and workmanship. Conklin and contrac<strong>to</strong>r jointly warrant Material and workmanship. Conklin and contrac<strong>to</strong>r jointly warrant Material and workmanship; Danosa will pay all authorized costs of repair<br />

that the Conklin membrane/coating will be free from water leaks that the Conklin system will be free from water leaks resulting from <strong>to</strong> <strong>Roof</strong>ing Membrane System necessary <strong>to</strong> s<strong>to</strong>p leaks resulting from<br />

resulting from ordinary wear and tear from the elements or from ordinary wear and tear from the elements or from improper deterioration of Danosa roofing membrane or flashing membrane system<br />

improper application. application. resulting from ordinary wear and tear by elements, improper workmanship<br />

in application, blisters, buckles, ridges, wrinkles attributed <strong>to</strong> roofing<br />

membrane and its workmanship, and splits or cracks not caused by<br />

structural failure or slippage.<br />

5 Length of coverage 1 <strong>to</strong> 10 years 1 <strong>to</strong> 15 years 5, 10, 15 years<br />

6 Nature of remedy Conklin and contrac<strong>to</strong>r, at their own expense, will supply the Conklin and contrac<strong>to</strong>r, at their own expense, will supply the Danosa will pay all authorized costs of repair necessary <strong>to</strong> s<strong>to</strong>p leaks<br />

necessary product and labor <strong>to</strong> correct leakage caused by ordinary necessary product and labor <strong>to</strong> correct leakage caused by ordinary<br />

wear and tear or improper application.<br />

wear and tear or improper application<br />

7 Monetary limitations Conklin's and contrac<strong>to</strong>r's obligation shall in no event exceed Conklin's and contrac<strong>to</strong>r's obligation shall in no event exceed Danosa's <strong>to</strong>tal cumulative liability not <strong>to</strong> exceed a per-square limitation<br />

either that portion of the original amount of the roofing contract either that portion of the original amount of the roofing contract established by Danosa at time of completion of warranty form<br />

that relates <strong>to</strong> the roofing membrane/coating and the labor that relates <strong>to</strong> the Conklin system and the labor required <strong>to</strong> apply<br />

required <strong>to</strong> apply the roofing membrane/coating or $250,000, the Conklin system or $250,000, whichever is lesser.<br />

whichever is lesser<br />

8 Notification requirements Written notification within 30 days following discovery of leak <strong>to</strong> Written notification within 30 days following discovery of leak <strong>to</strong> Written notice within 30 days of discovery of leak<br />

contrac<strong>to</strong>r and Conklin at P. O. Box 155, Shakopee, MN 55379. contrac<strong>to</strong>r and Conklin at P. O. Box 155, Shakopee, MN 55379.<br />

9 Exclusive or additional remedy Owner's sole and exclusive remedy shall be the replacement of Owner's sole and exclusive remedy shall be the replacement of Excludes other guarantees and warranties; excludes UCC warranties<br />

the defective membrane; warranty is given in lieu of any other the defective membrane; warranty is given in lieu of any other<br />

warranty; excludes UCC warranties; warran<strong>to</strong>rs shall not be liable warranty; excludes UCC warranties; warran<strong>to</strong>rs shall not be liable<br />

for any direct, indirect, incidental, consequential, special, or for any direct, indirect, incidental, consequential, special, or<br />

general damages resulting from failure of the Conklin system general damages resulting from failure of the Conklin system<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (no provision) Neutral (no provision) Neutral (no provision)<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 6, 7, 14, 15, 16, 24, 25 1, 2, 3, 4, 6, 7, 14, 15, 16, 24, 25 1, 2, 3, 4, 6, 7, 8, 9, 10, 12, 13, 17, 22. [Danosa indicates that 11, 15, 16,<br />

coverage (see Item 12 in<br />

18, 19, 23, 24, and 25 are also applicable.]<br />

Introduction)<br />

13 Wind coverage/exclusions Warranty excludes winds of peak gust speed of __ mph measured Warranty excludes winds of peak gust speed of __ mph measured Warranty excludes hurricanes. [Danosa indicates that there is no<br />

35 feet above the ground, hurricanes, and <strong>to</strong>rnadoes. Conklin 35 feet above the ground, hurricanes, and <strong>to</strong>rnadoes. Conklin coverage for damage caused by wind.]<br />

indicates that warranty will be issued excluding winds over 43 indicates that warranty will be issued excluding winds over 43<br />

miles per hour. Conklin indicates higher wind speed exclusions miles per hour. Conklin indicates higher wind speed exclusions<br />

can be obtained by submitting a wind speed application<br />

can be obtained by submitting a wind speed application.<br />

14 Specific conditions <strong>to</strong> make the A, B, C, D, E, F, H, J, S. Failure of owner <strong>to</strong> file an accurate, A, B, C, D, E, F, H, J, S. Failure of owner <strong>to</strong> file an accurate, C. [Danosa indicates that F, G, H, I, J, K, L, M, N, O, P, Q, and S are<br />

warranty ineffective or null and complete maintenance/inspection report annually within 30 days completed maintenance/inspection report annually within 30 days also applicable.]<br />

void (see Item 14 in Introduction) prior <strong>to</strong> anniversary of warranty effective date and failure <strong>to</strong> prior <strong>to</strong> anniversary of warranty effective date and failure <strong>to</strong><br />

complete repairs deemed necessary within 60 days of annual complete repairs deemed necessary within 60 days of annual<br />

inspection shall void the warranty. (See Special Features/Con- inspection shall void the warranty. (See Special Features/Conditions.)<br />

ditions.)<br />

15 Cost <strong>to</strong> obtain $5.00/square $8.00/square $6.00 square<br />

746


16 Minimum charge $500 $800 None<br />

17 Ineligible structure or building<br />

use<br />

None None None<br />

18 Pre-construction notice and<br />

approval requirements<br />

Contrac<strong>to</strong>r must complete preapplication forms and submit <strong>to</strong><br />

Conklin prior <strong>to</strong> starting job. Conklin's written approval <strong>to</strong> start the<br />

job is needed before work may begin. Conklin reserves the right <strong>to</strong><br />

preinspect the job, for a fee, prior <strong>to</strong> granting approval<br />

Contrac<strong>to</strong>r must complete preapplication forms and submit them<br />

<strong>to</strong> Conklin prior <strong>to</strong> starting job; manda<strong>to</strong>ry preinspection by Conklin<br />

prior <strong>to</strong> granting approval.<br />

Danosa requires a letter from contrac<strong>to</strong>r indicating date and Danosa<br />

specification number before commencing work<br />

19 Approved, authorized, or licensed<br />

requirements<br />

Yes Yes Yes<br />

20 Job inspection policy Conklin warranty inspec<strong>to</strong>r makes on-site inspection prior <strong>to</strong> Conklin warranty inspec<strong>to</strong>r makes on-site inspection prior <strong>to</strong> and<br />

application sometimes and after application prior <strong>to</strong> issuance of after application prior <strong>to</strong> issuance of warranty; $300 charge per day<br />

warranty; $300 charge per job per day, $100 for each additional for preapplication inspection and $300 charge per day for post--<br />

day. If roof passes first post-application inspection, $300 is applied application inspection; $100 charge for each additional day. If roof<br />

<strong>to</strong>ward cost of warranty. If roof fails the first post-application passes first post-application inspection, $300 is applied <strong>to</strong>ward<br />

inspection, $300 is retained and an additional $300 is due upon cost of warranty. If roof fails the first post-application inspection,<br />

scheduling of second post-application inspection<br />

$300 is retained and an additional $300 is due upon scheduling of<br />

second post-application inspection<br />

21 Contrac<strong>to</strong>r’s post-installation<br />

obligation<br />

22 Backed by named insurance or<br />

surety<br />

Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> all leaks, any defects, and<br />

material and workmanship deficiencies for two years.<br />

No; Conklin indicates that it does not carry insurance covering its<br />

warranty obligations<br />

Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> all leaks, any defects, and<br />

material and workmanship deficiencies for three years<br />

No; Conklin indicates that it does not carry insurance covering its<br />

warranty obligations<br />

Danosa inspec<strong>to</strong>r will inspect prior, during, and after application; will also<br />

inspect every five years; no charge<br />

Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for 10<br />

years<br />

No<br />

23 Issuing entity manufactures<br />

and/or sells products<br />

24 Conditions for renewal or<br />

extension<br />

Conklin sells product only Conklin sells product only Danosa manufactures and sells the product<br />

No renewal provision No renewal provision Five- or ten-year extension available if roof passes inspection and<br />

additional fee is paid<br />

25 Assignability Warranty may be transferred upon giving notification <strong>to</strong> Conklin Warranty may be transferred upon giving notification <strong>to</strong> Conklin<br />

and contrac<strong>to</strong>r in writing within 60 days of transfer and ownership and contrac<strong>to</strong>r in writing within 60 days of transfer and ownership<br />

of structure of the name of new building owner and the intended of structure of the name of new building owner and the intended<br />

use of building. Conklin may inspect roof for a fee and require any use of the building. Conklin may inspect roof for a fee and require<br />

modification it deems necessary <strong>to</strong> protect the membrane. Failure any modification it deems necessary <strong>to</strong> protect the roof system.<br />

<strong>to</strong> notify Conklin in timely manner renders warranty null and void Failure <strong>to</strong> notify Conklin in timely manner renders warranty null<br />

and void.<br />

26 Special features/condition The Conklin Limited Joint Warranty is a joint warranty obligating The Conklin Company, Inc. Total <strong>Roof</strong> System Limited Joint<br />

Conklin Company, Inc. and the contrac<strong>to</strong>r. The building owner Warranty is a joint warranty obligating Conklin Company, Inc. and<br />

must submit <strong>to</strong> Conklin a maintenance/ inspection report<br />

the contrac<strong>to</strong>r. Building owner must submit <strong>to</strong> Conklin a maintecompleted<br />

either by original contrac<strong>to</strong>r or another contrac<strong>to</strong>r nance/ inspection report completed either by original contrac<strong>to</strong>r or<br />

approved by Conklin on forms provided by Conklin. The required another contrac<strong>to</strong>r approved by Conklin on forms provided by<br />

maintenance inspection report must be filed annually not less than Conklin. The required maintenance inspection report must be filed<br />

30 days prior <strong>to</strong> the anniversary of the effective date of the annually not less than 30 days prior <strong>to</strong> the anniversary of the<br />

warranty. Failure <strong>to</strong> submit accurate, complete report voids the effective date of the warranty. Failure <strong>to</strong> submit accurate, complete<br />

warranty. If corrections are needed, roofing repairs not covered by report voids the warranty. If corrections are needed, roofing repairs<br />

the warranty must be completed within 60 days of the annual not covered by the warranty must be completed within 60 days of<br />

inspection, or warranty will be void. Conklin may require an the annual inspection, or warranty will be void. Conklin may<br />

inspection of repairs with inspection costs <strong>to</strong> be charged <strong>to</strong> require an inspection of repairs with inspection costs <strong>to</strong> be<br />

building owner at current inspection fee rates. Owner must give charged <strong>to</strong> building owner at current inspection fee rates. Owner<br />

written notice <strong>to</strong> Conklin and contrac<strong>to</strong>r within 30 days following must give written notice <strong>to</strong> Conklin and contrac<strong>to</strong>r within 30 days<br />

discovery of damage <strong>to</strong> roof not covered by warranty, must allow following discovery of damage <strong>to</strong> roof not covered by warranty,<br />

Conklin <strong>to</strong> inspect for a fee, and must make repairs in order for allow Conklin <strong>to</strong> inspect for a fee, and make repairs in order for<br />

warranty <strong>to</strong> remain in effect. Warranty interpreted and governed by warranty <strong>to</strong> remain in effect. Warranty interpreted and governed by<br />

laws of Minnesota.<br />

laws of Minnesota.<br />

Not assignable<br />

All repairs must be authorized in writing in advance by Danosa and all<br />

repairs must be performed only by a Danosa approved roofing contrac<strong>to</strong>r<br />

27 Executed by owner Yes; warranty also executed by contrac<strong>to</strong>r Yes; warranty also executed by contrac<strong>to</strong>r No<br />

747


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Dermabit Dermabit<br />

Dibiten,<br />

a division of Johns Manville Corporation<br />

2 Title, original publication Derma bit Waterproofing Industries Guarantee Material and Derma bit Waterproofing Industries Material Guarantee; April "15 Year Limited Material Warranty"; March 1997; RS-9012<br />

date, and identifying Labor; April 1988 1988 3-97<br />

symbol, if any<br />

3 Product, specification, or Derma bit APP 4170, 4170S; Elasphalt SBS 4170, 4170S Dermabit APP 4170; Elasphalt 4170, 4170S, SBS Dibiten Poly 5 specifications with roof coating: 501, 502,<br />

system covered<br />

503, 504, R505, R506<br />

4 Scope of coverage Material only; Dermabit guarantees that the membrane/ Material only; Dermabit guarantees that Dermabit membrane Material only; Dibiten warrants its roofing membrane <strong>to</strong> be<br />

flashing will not lose its waterproof quality due <strong>to</strong> natural will not lose its waterproof quality due <strong>to</strong> natural deterioration free of manufacturing defects<br />

deterioration of the membrane, bare spots, ridges, or splits not of the membrane, bare spots, ridges, or splits not caused by<br />

caused by structural failure or movement of or cracks in sub- structural failure or movement of or cracks in substrate or roof<br />

strate, roof base, or insulation<br />

base or insulation.<br />

5 Length of coverage 10 years: Dermabit 4170 APP, 4170 SBS (must be coated); 10 years 15 years<br />

12 years: Dermabit 4170, 4170S APP, SBS 4170, 4170S (all<br />

smooth surfaced specifications must be coated); 20 years;<br />

Dermabit 4170, 4170S APP, SBS 4170, 4170S (must be two<br />

layers and coated)<br />

6 Nature of remedy Dermabit shall replace and/or repair any part of the Dermabit Dermabit, in its sole discretion, will either refund <strong>to</strong> owner a If the Dibiten membrane is proved <strong>to</strong> have manufacturing<br />

membrane/flashing as shall be necessary solely in order <strong>to</strong> prorated portion of the original purchase price of the defective defects that affect the watertight integrity of the membrane,<br />

s<strong>to</strong>p water leaks Dermabit membrane or provide, at no cost <strong>to</strong> owner, a portion Dibiten will pay a share, on a pro-rata basis (1/15 per year)<br />

of the Dermabit membrane required <strong>to</strong> replace defective of all costs including materials and labor, for repair or<br />

membrane.<br />

replacement of the defective Dibiten membrane.<br />

7 Monetary limitations Dermabit's obligation over the life of guarantee is the aggre- Original purchase price reduced in accordance with a prorated Dibiten's liability not <strong>to</strong> exceed the original cost of the<br />

gate amount equal <strong>to</strong> the amount that was paid by owner for schedule ranging from 100 percent of original purchase price membrane<br />

supply and installation of the Dermabit membrane/flashing during the first two years of roof service <strong>to</strong> 10 percent in year<br />

covered by the guarantee. 10.<br />

8 Notification requirements Written notification by certified mail <strong>to</strong> D.W.I., Incorporated, Written notification by certified mail <strong>to</strong> D.W.I., Incorporated, Written notice within 30 days of discovery of water leaks<br />

P.O. Box 1154, McLean, VA 22101, within 10 days after P.O. Box 1154, McLean, VA 22101, within 10 days after through the Dibiten membrane <strong>to</strong> Dibiten, P.O. Box 5108,<br />

discovery of any leak discovery of any leak Denver, Colorado 80217-5108.<br />

9 Exclusive or additional Excludes UCC warranties and any other obligations or liability Dermabit's obligation <strong>to</strong> refund a portion of owner's original Warranty is exclusive warranty from Dibiten and represents<br />

remedy on the part of Dermabit purchase price or <strong>to</strong> provide a portion of new membrane shall the exclusive remedy available <strong>to</strong> any purchaser of the<br />

be the owner's sole and exclusive remedy; excludes UCC membrane materials. Dibiten makes no other<br />

warranties and any other obligations or liability on the part of representation or warranty of any kind. No retailer,<br />

Dermabit<br />

contrac<strong>to</strong>r or distribu<strong>to</strong>r is authorized <strong>to</strong> alter the warranty.<br />

Dibiten shall not be liable for any damages which are based<br />

on negligence, breach of warranty, strict liability or any other<br />

theory other than the limited liability stated in warranty;<br />

excludes UCC warranties<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (no provision) Neutral (no provision) Neutral (no provision)<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 16, 17, 18 (including 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 16, 17, 18 (including 1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 13, 17, 19, 20, 22<br />

coverage (see Item 12 in exposure <strong>to</strong> any chemical or solution, radiation, or exposure <strong>to</strong> any chemical or solution, radiation, or<br />

Introduction) contamination by radioactivity from any nuclear fuel waste), contamination by radioactivity from any nuclear fuel or waste),<br />

22, 23 22, 23. (Also excludes failure of underlying materials or<br />

structures <strong>to</strong> conform <strong>to</strong> manufacturer's specifications as <strong>to</strong><br />

roof slopes or other requirements.<br />

13 Wind coverage/exclusions Warranty excludes winds<strong>to</strong>rms, hurricanes, and <strong>to</strong>rnadoes Warrant excludes winds<strong>to</strong>rms, hurricanes, and Warranty excludes wind and hurricanes. Dibiten indicates<br />

<strong>to</strong>rnadoes y.<br />

that there is no coverage for damage caused by wind.<br />

748


14 Specific conditions <strong>to</strong> B (see Special Features/Conditions), C, H, R. Cancellation of B (see Special Features/Conditions), C, H, R. Cancellation of C, F, H, I, M, R<br />

make the warranty this guarantee will also result if building is damaged by any this guarantee will also result if building is damaged by any<br />

ineffective or null and void cause listed in Specific Exclusions from Coverage so as <strong>to</strong> cause listed under Specific Exclusions from Coverage so as <strong>to</strong><br />

(see Item 14 in affect the waterproof quality of the membrane or water affect waterproof quality of membrane or watertightness of<br />

Introduction) tightness of structure. structure.<br />

15 Cost <strong>to</strong> obtain None None None<br />

16 Minimum charge None None None<br />

17 Ineligible structure or Cold-s<strong>to</strong>rage buildings Cold-s<strong>to</strong>rage buildings Structures used for cool or cold s<strong>to</strong>rage<br />

building use<br />

18 Pre-construction notice None None None<br />

and approval requirements<br />

19 Approved, authorized, or Yes No Yes<br />

licensed requirements<br />

20 Job inspection policy No on-site inspections. Owners signature on a 48-hour No on-site inspections No on-site inspections<br />

Flood test required<br />

21 Contrac<strong>to</strong>r’s post- Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship None None; material-only warranty<br />

installation obligation deficiencies for two years<br />

22 Backed by named No; Dermabit indicates that it carries $1 million product-lia- No; Dermabit indicates that it carries $1 million product- No; Dibiten indicates that it does not carry insurance<br />

insurance or surety bility insurance coverage liability insurance coverage covering its warranty obligations<br />

23 Issuing entity Dermabit manufactures and sells product Dermabit manufactures and sells product Dibiten manufactures and sells product.<br />

manufactures and/or sells<br />

products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision.<br />

extension<br />

25 Assignability Not assignable Not assignable No restrictions stated<br />

26 Special features/condition No action, suit, claim, or other proceeding arising out of or No action, suit, claim, or other proceeding arising out of or In order <strong>to</strong> continue limited warranty coverage, owner must<br />

relating <strong>to</strong> the Dermabit membrane or this guarantee may be relating <strong>to</strong> the Dermabit membrane or this guarantee may be implement a maintenance program prescribed by Dibiten on<br />

filed or commenced later than one year after the expiration of filed or commenced later than one year after the expiration of the reverse side of limited warranty, including repair of any<br />

the term of this guarantee. Owner shall give 30 days' prior the term of this guarantee. Owner shall give 30 days' prior item beyond the scope of the warranty which would affect<br />

written notice <strong>to</strong> Dermabit of owner's intention <strong>to</strong> repair or written notice <strong>to</strong> Dermabit of owner's intention <strong>to</strong> repair or the integrity of the Dibiten membrane and recoating smooth<br />

modify roof or other surface over which membrane is installed, modify roof or other surface over which membrane is installed, surfaced membranes as necessary and: (a) maintaining a<br />

including plans and specifications for the proposed repairs or including plans and specifications for the proposed repairs or file showing proof-of-purchase, all inspections and repairs;<br />

modifications. No Dermabit representative, employee, or modifications. No Dermabit representative, employee, or (b) inspecting roof at least semiannually; (c) removing any<br />

agent or any other person has the authority <strong>to</strong> assume any agent or any other person has authority <strong>to</strong> assume any debris; (d) cleaning gutters, downspouts, drains, and<br />

additional or other liability or responsibility in connection with additional or other liability or responsibility in connection with surrounding areas; (e) repairing damaged masonry, poorly<br />

the membrane installed the membrane installed mounted counterflashing, loose caulking, bad mortar joints,<br />

and any loose s<strong>to</strong>ne or tile coping that abut the roof; (f)<br />

correcting materials at edges of the roof that have been<br />

lifted by wind by an approved contrac<strong>to</strong>r; (g) examining roof<br />

<strong>to</strong>p equipment <strong>to</strong> determine if they move excessively or<br />

leak; (h) checking building exterior for settlement or<br />

movement; and (i) recoating any areas of excessive wear,<br />

flaking, or blistered areas of protective coatings.<br />

Installing roofing contrac<strong>to</strong>r must be licensed by and in<br />

good standing with the licensing authority of the jurisdiction<br />

in which the structure is located.<br />

Region 2 excludes CA, NV, AZ, UT, ID, NM, TX, HI, FL.<br />

27 Executed by owner No No Registration form must be completed and returned <strong>to</strong> Dibiten within 30<br />

days of completion of the Dibiten membrane and a copy of the<br />

contrac<strong>to</strong>r's bill must be attached<br />

749


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity<br />

Dibiten, Dibiten, Dibiten,<br />

a division of Johns Manville Corporation a division of Johns Manville Corporation a division of Johns Manville Corporation<br />

2 Title, original publication “20 Year Limited Material Warranty"; March 1997; RS-9013 3- “10 Year Limited Material Warranty"; March 1997; RS-9010 3- “6 Year Limited Material Warranty"; March 1997; RS-9009<br />

date, and identifying 97 97 3-97<br />

symbol, if any<br />

3 Product, specification, or Dibiten Poly/4 Two Ply Specifications: 401-2, 402-2, 403-2, Dibiten Poly 4 Uncoated Specifications: 401, 402, 403, 404, Dibiten Poly/4 Uncoated Specifications 401, 402, 403, 404,<br />

system covered 404-2 ; Dibiten Poly 4.5 Two Ply Specifications: 451-2, 452-2, 405, 406 in Region 2; Dibiten Poly 4.5 Granular Specifications: 405, 406<br />

453-2, 454-2 451, 452, 453, 454, R455, R456; Dibiten Poly 5 Uncoated<br />

Specifications: 501, 502, 503, 504, R505, R506<br />

4 Scope of coverage Material only; Dibiten warrants its roofing membrane <strong>to</strong> be free Material only; Dibiten warrants its roofing membrane <strong>to</strong> be free Material only; Dibiten warrants its roofing membrane <strong>to</strong> be<br />

of manufacturing defects. of manufacturing defects free of manufacturing defects.<br />

5 Length of coverage 20 years 10 years 6 years<br />

6 Nature of remedy If the Dibiten membrane is proved <strong>to</strong> have manufacturing If the Dibiten membrane is proved <strong>to</strong> have manufacturing If the Dibiten membrane is proved <strong>to</strong> have manufacturing<br />

defects that affect the watertight integrity of the membrane, defects that affect the watertight integrity of the membrane, defects that affect the watertight integrity of the membrane,<br />

Dibiten will pay a share, on a pro-rata basis (1/20 per year) of Dibiten will pay a share, on a pro-rata basis (1/10 per year) of Dibiten will pay a share, on a pro-rata basis (1/6 per year) of<br />

all costs including materials and labor, for repair or all costs including materials and labor, for repair or all costs including materials and labor, for repair or<br />

replacement of the defective Dibiten membrane replacement of the defective Dibiten membrane replacement of the defective Dibiten membrane<br />

7 Monetary limitations Dibiten's liability not <strong>to</strong> exceed the original cost of the Dibiten's liability not <strong>to</strong> exceed the original cost of the Dibiten's liability not <strong>to</strong> exceed the original cost of the<br />

membrane membrane. membrane<br />

8 Notification requirements Written notice within 30 days of discovery of water leaks Written notice within 30 days of discovery of water leaks Written notice within 30 days of discovery of water leaks<br />

through the Dibiten membrane <strong>to</strong> Dibiten, P.O. Box 5108, through the Dibiten membrane <strong>to</strong> Dibiten, P.O. Box 5108, through the Dibiten membrane <strong>to</strong> Dibiten, P.O. Box 5108,<br />

Denver, Colorado 80217-5108. Denver, Colorado 80217-5108. Denver, Colorado 80217-5108.<br />

9 Exclusive or additional Warranty is exclusive warranty from Dibiten and represents Warranty is exclusive warranty from Dibiten and represents Warranty is exclusive warranty from Dibiten and represents<br />

remedy the exclusive remedy available <strong>to</strong> any purchaser of the the exclusive remedy available <strong>to</strong> any purchaser of the the exclusive remedy available <strong>to</strong> any purchaser of the<br />

membrane materials. Dibiten makes no other representation membrane materials. Dibiten makes no other representation membrane materials. Dibiten makes no other<br />

or warranty of any kind. No retailer, contrac<strong>to</strong>r or distribu<strong>to</strong>r is or warranty of any kind. No retailer, contrac<strong>to</strong>r or distribu<strong>to</strong>r is representation or warranty of any kind. No retailer,<br />

authorized <strong>to</strong> alter the warranty. Dibiten shall not be liable for authorized <strong>to</strong> alter the warranty. Dibiten shall not be liable for contrac<strong>to</strong>r or distribu<strong>to</strong>r is authorized <strong>to</strong> alter the warranty.<br />

any damages which are based on negligence, breach of any damages which are based on negligence, breach of Dibiten shall not be liable for any damages which are based<br />

warranty, strict liability or any other theory other than the warranty, strict liability or any other theory other than the on negligence, breach of warranty, strict liability or any other<br />

limited liability stated in warranty; excludes UCC warranties limited liability stated in warranty; excludes UCC warranties. theory other than the limited liability stated in warranty;<br />

excludes UCC warranties<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (no provision) Neutral (no provision) Neutral (no provision)<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 13, 17, 19, 20, 22 1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 13, 17, 19, 20, 22 1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 13, 17, 19, 20, 22<br />

coverage (see Item 12 in<br />

Introduction)<br />

13 Wind coverage/exclusions Warranty excludes wind and hurricanes. Dibiten indicates that Warranty excludes wind and hurricanes. Dibiten indicates that Warranty excludes wind and hurricanes. Dibiten indicates<br />

there is no coverage for damage caused by wind. there is no coverage for damage caused by wind. that there is no coverage for damage caused by wind.<br />

14 Specific conditions <strong>to</strong> C, F, H, I, M, R C, F, H, I, M, R C, F, H, I, M, R<br />

make the warranty<br />

ineffective or null and void<br />

(see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain None None None<br />

16 Minimum charge None None None<br />

750


17 Ineligible structure or<br />

building use<br />

18 Pre-construction notice<br />

and approval requirements<br />

19 Approved, authorized, or<br />

licensed requirements<br />

Structures used for cool or cold s<strong>to</strong>rage Structures used for cool or cold s<strong>to</strong>rage Structures used for cool or cold s<strong>to</strong>rage<br />

None None None<br />

Yes Yes Yes<br />

20 Job inspection policy No on-site inspections No on-site inspections No on-site inspections<br />

21 Contrac<strong>to</strong>r’s postinstallation<br />

obligation<br />

22 Backed by named<br />

insurance or surety<br />

23 Issuing entity<br />

manufactures and/or sells<br />

products<br />

24 Conditions for renewal or<br />

extension<br />

None; material-only warranty None; material-only warranty None; material-only warranty<br />

No; Dibiten indicates that it does not carry insurance covering No; Dibiten indicates that it does not carry insurance covering No; Dibiten indicates that it does not carry insurance<br />

its warranty obligations its warranty obligations covering its warranty obligations.<br />

Dibiten manufactures and sells product. Dibiten manufactures and sells product. Dibiten manufactures and sells product<br />

No renewal provision. No renewal provision. No renewal provision<br />

25 Assignability No restrictions stated. Warranty states that it is made <strong>to</strong> the No restrictions stated No restrictions stated<br />

original owner.<br />

26 Special features/condition In order <strong>to</strong> continue limited warranty coverage, owner must In order <strong>to</strong> continue limited warranty coverage, owner must In order <strong>to</strong> continue limited warranty coverage, owner must<br />

implement a maintenance program prescribed by Dibiten on implement a maintenance program prescribed by Dibiten on implement a maintenance program prescribed by Dibiten on<br />

the reverse side of limited warranty, including repair of any the reverse side of limited warranty, including repair of any the reverse side of limited warranty, including repair of any<br />

item beyond the scope of the warranty which would affect the item beyond the scope of the warranty which would affect the item beyond the scope of the warranty which would affect<br />

integrity of the Dibiten membrane and recoating smooth integrity of the Dibiten membrane and recoating smooth the integrity of the Dibiten membrane and recoating smooth<br />

surfaced membranes as necessary and: (a) maintaining a file surfaced membranes as necessary and: (a) maintaining a file surfaced membranes as necessary and: (a) maintaining a<br />

showing proof-of-purchase, all inspections and repairs; (b) showing proof-of-purchase, all inspections and repairs; (b) file showing proof-of-purchase, all inspections and repairs;<br />

inspecting roof at least semiannually; (c) removing any debris; inspecting roof at least semiannually; (c) removing any debris; (b) inspecting roof at least semiannually; © removing any<br />

(d) cleaning gutters, downspouts, drains, and surrounding (d) cleaning gutters, downspouts, drains, and surrounding debris; (d) cleaning gutters, downspouts, drains, and<br />

areas; (e) repairing damaged masonry, poorly mounted areas; (e) repairing damaged masonry, poorly mounted surrounding areas; (e) repairing damaged masonry, poorly<br />

counterflashing, loose caulking, bad mortar joints, and any counterflashing, loose caulking, bad mortar joints, and any mounted counter-flashing, loose caulking, bad mortar joints,<br />

loose s<strong>to</strong>ne or tile coping that abut the roof; (f) correcting loose s<strong>to</strong>ne or tile coping that abut the roof; (f) correcting and any loose s<strong>to</strong>ne or tile coping that abut the roof; (f)<br />

materials at edges of the roof that have been lifted by wind by materials at edges of the roof that have been lifted by wind by correcting materials at edges of the roof that have been<br />

an approved contrac<strong>to</strong>r; (g) examining roof <strong>to</strong>p equipment <strong>to</strong> an approved contrac<strong>to</strong>r; (g) examining roof <strong>to</strong>p equipment <strong>to</strong> lifted by wind by an approved contrac<strong>to</strong>r; (g) examining roof<br />

determine if they move excessively or leak; (h) checking determine if they move excessively or leak; (h) checking <strong>to</strong>p equipment <strong>to</strong> determine if they move excessively or<br />

building exterior for settlement or movement; and (i) recoating building exterior for settlement or movement; and (i) recoating leak; (h) checking building exterior for settlement or<br />

any areas of excessive wear, flaking, or blistered areas of any areas of excessive wear, flaking, or blistered areas of movement; and (I) recoating any areas of excessive wear,<br />

protective coatings. protective coatings. flaking, or blistered areas of protective coatings.<br />

Installing roofing contrac<strong>to</strong>r must be licensed by and in Installing roofing contrac<strong>to</strong>r must be licensed by and in Installing roofing contrac<strong>to</strong>r must be licensed<br />

good standing with the licensing authority of the jurisdiction in good standing with the licensing authority of the jurisdiction in by and in good standing with the licensing authority of the<br />

which the structure is located. which the structure is located. jurisdiction in which the structure is located.<br />

Region 2 excludes CA, NV, AZ, UT, ID, NM, TX, HI, FL. Region 2 excludes CA, NV, AZ, UT, ID, NM, TX, HI, FL. Region 2 excludes CA, NV, AZ, UT, ID, NM, TX,<br />

HI, FL.<br />

27 Executed by owner Registration form must be completed and returned <strong>to</strong> Dibiten Registration form must be completed and returned <strong>to</strong> Dibiten<br />

within 30 days of completion of the Dibiten membrane and a within 30 days of completion of the Dibiten membrane and a<br />

copy of the contrac<strong>to</strong>r's bill must be attached<br />

copy of the contrac<strong>to</strong>r's bill must be attached<br />

Registration form must be completed and returned <strong>to</strong> Dibiten within 30<br />

days of completion of the Dibiten membrane and a copy of the<br />

contrac<strong>to</strong>r's bill must be attached<br />

751


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

Dibiten,<br />

1 Identity of issuing entity Duro-Last <strong>Roof</strong>ing, Inc. Duro-Last <strong>Roof</strong>ing, Inc.<br />

a division of Johns Manville Corporation<br />

2 Title, original publication "12 Year Limited Material Warranty"; September 1997; RS- “15 Year Residential Material Warranty”; March 1993; DL 15- “15 Year Warranty”; August 1, 1991; DL 15-00 Rev.<br />

date, and identifying 9011 9-97 01 Rev. 3/93<br />

symbol, if any<br />

3 Product, specification, or Dibiten Poly 4 Specifications with roof coating: 401, 402, 404, Duro-Last <strong>Roof</strong>ing System Duro-Last<br />

system covered<br />

R405, R406<br />

4 Scope of coverage Material only; Dibiten warrants its roofing membrane <strong>to</strong> be free Material only; Duro-Last grants a material-only warranty <strong>to</strong> the Material and workmanship; Duro-Last grants a limited<br />

of manufacturing defects owner of a building with a roof on a porch, sun deck, garage, warranty <strong>to</strong> the building owner that it will repair any leak in a<br />

s<strong>to</strong>rage shed, or single-family residence and installed by an Duro-Last roof caused by any defect in Duro-Last<br />

authorized dealer/ contrac<strong>to</strong>r that the Duro-Last membrane membrane materials or accessories or workmanship of the<br />

material and accessories will be free from manufacturing authorized dealer/contrac<strong>to</strong>r. Warranty does not extend <strong>to</strong><br />

defects at the time of delivery and the membrane material and color.<br />

accessories will not become defective within the term of the<br />

warranty. Warranty does not extend <strong>to</strong> color.<br />

5 Length of coverage 12 years 15 year 15 years<br />

6 Nature of remedy If the Dibiten membrane is proved <strong>to</strong> have manufacturing Should a defect occur in the membrane material or Provided that Duro-Last has authorized the repair and an<br />

defects that affect the watertight integrity of the membrane, accessories within the warranty, Duro-Last's liability limited authorized dealer/contrac<strong>to</strong>r makes the repair, Duro-Last's<br />

Dibiten will pay a share, on a pro-rata basis (1/12 per year) of solely <strong>to</strong> provide the materials necessary <strong>to</strong> make the repairs. obligation is <strong>to</strong> repair any covered leak in the roof, including<br />

all costs including materials and labor, for repair or<br />

replacement of the defective Dibiten membrane<br />

repair or replacement of membrane material and<br />

accessories and the cost of or furnishing labor <strong>to</strong> repair roof<br />

at the contrac<strong>to</strong>r list price in effect at the time of repair.<br />

7 Monetary limitations Dibiten's liability not <strong>to</strong> exceed the original cost of the None stated. Duro-Last's liability for cost of labor <strong>to</strong> repair roof is at the<br />

membrane<br />

contrac<strong>to</strong>r's list price in effect at time of repair; otherwise, no<br />

monetary limitations stated<br />

8 Notification requirements Written notice within 30 days of discovery of water leaks Written notification <strong>to</strong> Duro-Last's corporate headquarters, 525 Written notification <strong>to</strong> Duro-Last's corporate headquarters,<br />

through the Dibiten membrane <strong>to</strong> Dibiten, P.O. Box 5108, Morley Drive, Saginaw, MI 48601, within 30 days after 525 Morley Drive, Saginaw, MI 48601, within 30 days after<br />

Denver, Colorado 80217-5108. discovery of any defective material discovery of any leak<br />

9 Exclusive or additional Warranty is exclusive warranty from Dibiten and represents Warranty is owner's sole and exclusive remedies for failure of No warranties, representations, promises, or oral<br />

remedy the exclusive remedy available <strong>to</strong> any purchaser of the the roofing membrane material or accessories; excludes UCC statements have been made by any representative of Duro--<br />

membrane materials. Dibiten makes no other representation warranties. (See Special Features/Conditions.) Last, and owner is not <strong>to</strong> rely on same unless added <strong>to</strong> the<br />

or warranty of any kind. No retailer, contrac<strong>to</strong>r or distribu<strong>to</strong>r is<br />

warranty in writing. (See Special Features / Conditions.)<br />

authorized <strong>to</strong> alter the warranty. Dibiten shall not be liable for<br />

any damages which are based on negligence, breach of<br />

warranty, strict liability or any other theory other than the<br />

limited liability stated in warranty; excludes UCC warranties<br />

10 Inclusion of consequential No No No express exclusion<br />

damages<br />

11 Determination of warranty Neutral (no provision) Neutral (no provision) Neutral (no provision)<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 13, 17, 19, 20, 22 1, 3, 18. Warranty also excludes damages caused by 1, 2, 3, 4, 6, 10, 12, 14, 16, 18, 24. Warranty also excludes<br />

coverage (see Item 12 in chemicals not normally found in nature damages caused by chemicals not normally found in nature.<br />

Introduction)<br />

[Duro-Last indicates warranty covers damage caused by<br />

oils, wax, grease, animal fats, and acids.]<br />

13 Wind coverage/exclusions Warranty excludes wind and hurricanes. Dibiten indicates that Warranty excludes gales, hurricanes, and <strong>to</strong>rnadoes.<br />

there is no coverage for damage caused by wind.<br />

[Duro-Last does not indicate wind speeds covered by<br />

warranty.]<br />

752


14 Specific conditions <strong>to</strong><br />

make the warranty<br />

ineffective or null and void<br />

(see Item 14 in<br />

Introduction)<br />

C, F, H, I, M, R A, C, I A, C, G, I<br />

15 Cost <strong>to</strong> obtain None None None<br />

16 Minimum charge None None None<br />

17 Ineligible structure or<br />

building use<br />

18 Pre-construction notice<br />

and approval requirements<br />

19 Approved, authorized, or<br />

licensed requirements<br />

Structures used for cool or cold s<strong>to</strong>rage None Porch, sun deck, garage, s<strong>to</strong>rage shed, or single-family<br />

residence of less than 1,000 square feet<br />

None None required None<br />

Yes Yes Yes<br />

20 Job inspection policy No on-site inspections No on-site inspections Duro-Last quality assurance specialist makes on-site<br />

inspection after application prior <strong>to</strong> issuance of warranty; no<br />

charge<br />

21 Contrac<strong>to</strong>r’s postinstallation<br />

obligation<br />

22 Backed by named<br />

insurance or surety<br />

23 Issuing entity<br />

manufactures and/or sells<br />

products<br />

24 Conditions for renewal or<br />

extension<br />

None; material-only warranty Although this is a material-only warranty, contrac<strong>to</strong>r obligated Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

<strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for two years deficiencies for two years<br />

No; Dibiten indicates that it does not carry insurance covering No; Duro-Last indicates that it does not carry insurance No; Duro-Last indicates that it carries $12 million liability<br />

its warranty obligations. covering its warranty obligations insurance coverage<br />

Dibiten manufactures and sells product Duro-Last manufactures and sells product Duro-Last fabricates and sells product<br />

No renewal provision No renewal provision No renewal provision<br />

25 Assignability No restrictions stated No restrictions stated Assignable with written permission of Duro-Last, Inc.<br />

26 Special features/condition In order <strong>to</strong> continue limited warranty coverage, owner must implement a<br />

maintenance program prescribed by Dibiten on the reverse side of limited<br />

warranty, including repair of any item beyond the scope of the warranty<br />

which would affect the integrity of the Dibiten membrane and recoating<br />

smooth surfaced membranes as necessary and: (a) maintaining a file<br />

showing proof-of-purchase, all inspections and repairs; (b) inspecting roof at<br />

least semiannually; © removing any debris; (d) cleaning gutters,<br />

downspouts, drains, and surrounding areas; (e) repairing damaged<br />

masonry, poorly mounted counter-flashing, loose caulking, bad mortar<br />

joints, and any loose s<strong>to</strong>ne or tile coping that abut the roof; (f) correcting<br />

materials at edges of the roof that have been lifted by wind by an approved<br />

contrac<strong>to</strong>r; (g) examining roof <strong>to</strong>p equipment <strong>to</strong> determine if they move<br />

excessively or leak; (h) checking building exterior for settlement or<br />

movement; and (I) recoating any areas of excessive wear, flaking, or<br />

blistered areas of protective coatings.<br />

Installing roofing contrac<strong>to</strong>r must be licensed<br />

by and in good standing with the licensing authority of the jurisdiction in<br />

which the structure is located.<br />

Region 2 excludes CA, NV, AZ, UT, ID, NM, TX,<br />

HI, FL<br />

All interpretations of this warranty shall be considered that<br />

their form, execution, and validity thereof shall be controlled by<br />

the laws of the state of Michigan. Oral representations cannot<br />

be relied upon as correctly stating the representations of Duro-<br />

Last <strong>Roof</strong>ing, Inc.<br />

Owner's failure <strong>to</strong> comply with the terms and limitations in<br />

the limited warranty releases Duro-Last from any liability. All<br />

interpretations of this warranty shall be considered that their<br />

form, execution, and validity thereof shall be controlled by<br />

the laws of the state of Michigan. Duro-Last does not waive<br />

any rights under this limited warranty if it does not enforce<br />

the limitations. Oral representations cannot be relied upon<br />

as correctly stating the representations of Duro-Last, Inc.<br />

27 Executed by owner Registration form must be completed and returned <strong>to</strong> Dibiten No Yes<br />

within 30 days of completion of the Dibiten membrane and a<br />

copy of the contrac<strong>to</strong>r's bill must be attached.<br />

753


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Elas<strong>to</strong>meric <strong>Roof</strong>ing Systems, Inc. Elas<strong>to</strong>meric <strong>Roof</strong>ing Systems, Inc. Elas<strong>to</strong>meric <strong>Roof</strong>ing Systems, Inc.<br />

2 Title, original publication “ERSystems _____ Year EPDM <strong>Roof</strong> System Warranty"; "ERSystems ____ Year EPDM Membrane Material Warranty"; "ERSystems ____ Year Permaweld CPA Material<br />

date, and identifying Oc<strong>to</strong>ber 1, 1996; 961001 RSW Oc<strong>to</strong>ber 1, 1996; 961001 MMW<br />

Warranty"; Oc<strong>to</strong>ber 1, 1996; 961001 PMMW<br />

symbol, if any<br />

3 Product, specification, or .045 and .060 black nonreinforced EPDM; .045 and .060 black FR .045 and .060 black nonreinforced EPDM, .045 and .060 black FR Permaweld, Permaweld Fleece Backed, PermaVac systems<br />

system covered EPDM; reinforced 90, plate bond, fully adhered, ballasted, batten EPDM, reinforced 90, Poly-Bond; plate bond, fully adhered,<br />

ballasted, batten and Poly-Bond systems<br />

4 Scope of coverage Material and workmanship; ERSystems warrants <strong>to</strong> repair or Material only; ERSystems warrants that the roofing membrane is Material only; ERSystems warrants that the roofing membrane<br />

cause <strong>to</strong> be repaired any leak in the membrane system caused by free from manufacturing defects at the time the material is is free from manufacturing defects at the time the material is<br />

premature deterioration due <strong>to</strong> weathering or a defect in the delivered and that the product will not prematurely deteriorate <strong>to</strong> delivered and that the product will not prematurely deteriorate <strong>to</strong><br />

ERSystems materials or in the workmanship of installing the the point of failure due <strong>to</strong> weathering if properly installed, the point of failure due <strong>to</strong> weathering if properly installed,<br />

system. The system is defined as the elas<strong>to</strong>meric membrane, maintained, and used for the purpose for which the membrane is maintained, and used for the purpose for which the membrane<br />

adhesives, sealants, flashing membrane, fasteners and insulation intended. Warranty covers the membrane only and does not is intended. Warranty covers the membrane only and does not<br />

supplied by ERSystems. All materials not supplied by ERSystems cover adhesives, sealants, flashings, seams, coatings, cover adhesives, sealants, flashings, seams, coatings,<br />

must be approved in writing by ERSystems. accessories, or workmanship accessories, or workmanship.<br />

5 Length of coverage 5 or 10 years: Poly-Bond; 5, 10, or 15 years: .045 and .060 black 5 or 10 years: Poly-Bond; 5, 10, or 15 years: .045 and .060 black 5, 10, or 15 years<br />

nonreinforced EPDM, .045 and .060 black FR EPDM, reinforced nonreinforced EPDM, .045 and .060 black FR EPDM, reinforced<br />

90 90<br />

6 Nature of remedy The owner's remedies and ERSystems' liability is limited <strong>to</strong> the If the product shows premature deterioration due <strong>to</strong> weathering, If the product shows premature deterioration due <strong>to</strong> weathering,<br />

cost of repair of the leaks in the system. ERSystems liability is limited, at ERSystems option, <strong>to</strong> provide the ERSystems liability is limited, at ERSystems option, <strong>to</strong> provide<br />

repair material for the original product or credit <strong>to</strong>ward the the repair material for the original product or credit <strong>to</strong>ward the<br />

purchase of new membrane <strong>to</strong> repair the leak<br />

purchase of new membrane <strong>to</strong> repair the leak<br />

7 Monetary limitations None stated. The maximum value allowed by ERSystems for the repair or credit The maximum value allowed by ERSystems for the repair or<br />

shall not exceed the original product purchase price<br />

credit shall not exceed the original product purchase price<br />

8 Notification requirements The buyer must notify ERSystems by registered mail, return The buyer must notify ERSystems by registered mail, return The buyer must notify ERSystems by registered mail, return<br />

receipt requested, at 50 Medina Street, Loret<strong>to</strong>, MN 55357-0056, receipt requested, at 50 Medina Street, Loret<strong>to</strong>, MN 55357-0056, receipt requested, at 50 Medina Street, Loret<strong>to</strong>, MN 55357-<br />

within 30 days of discovery of the failure. within 30 days of discovery of the failure 0056, within 30 days of discovery of the failure<br />

9 Exclusive or additional The warranty is exclusive and in lieu of any other warranties; The warranty is exclusive and in lieu of any other warranties; The warranty is exclusive and in lieu of any other warranties;<br />

remedy ERSystems shall have no further obligation or liability of any kind. ERSystems shall have no further obligation or liability of any kind. ERSystems shall have no further obligation or liability of any<br />

ERSystems' sales personnel are not authorized <strong>to</strong> make ERSystems' sales personnel are not authorized <strong>to</strong> make kind. ERSystems' sales personnel are not authorized <strong>to</strong> make<br />

warranties; ERSystems' employees' oral statements do not warranties; ERSystems' employees' oral statements do not warranties; ERSystems' employees' oral statements do not<br />

constitute warranties and shall not be relied upon; excludes UCC constitute warranties and shall not be relied upon; excludes UCC constitute warranties and shall not be relied upon; excludes<br />

warranties. warranties UCC warranties<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty ERSystems' determination ERSystems' determination ERSystems' determination<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 16, 17, 18, 20, 22, 23. Warranty 1, 2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 16, 17, 18, 20, 22, 23. 1, 2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 16, 17, 18, 20, 22, 23. Warranty<br />

coverage (see Item 12 in also specifically excludes damages caused by a<strong>to</strong>mic radiation, Warranty also specifically excludes damages caused by a<strong>to</strong>mic also specifically excludes damages caused by a<strong>to</strong>mic radiation,<br />

Introduction) insects or animals, and specific Condition P. radiation, insects or animals, and Specific Condition P insects or animals, and specific Condition P<br />

13 Wind coverage/exclusions The warranty covers roof damage resulting from wind speeds up The warranty covers roof damage resulting from wind speeds up The warranty covers roof damage resulting from wind speeds up<br />

<strong>to</strong> 55 mph. Warranty excludes gales (exceeding 55 mph) and <strong>to</strong> 55 mph. The warranty excludes gales (exceeding 55 mph) and <strong>to</strong> 55 mph. Warranty excludes gales (exceeding 55 mph) and<br />

<strong>to</strong>rnadoes. <strong>to</strong>rnadoes <strong>to</strong>rnadoes<br />

14 Specific conditions <strong>to</strong> make C, M, S (See Special Features/Conditions.) C, M, S (See Special Features/Conditions.) C, M, S (See Special Features/Conditions.)<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain 5 years: $8.00/square; 10 years: $11.00/square; 15 years: 5 years: $50; 10 years: $75; 15 years: $2.00/square 5 years: $50; 10 years: $75; 15 years: $2.00/square<br />

$15.00 /square<br />

754


16 Minimum charge 5 years: $600; 10 years: $800; 15 years: $1,000 5 years: $50; 10 years: $75; 15 years: $100 5 years: $50; 10 years: $75; 15 years: $100<br />

17 Ineligible structure or Cold-s<strong>to</strong>rage buildings, single-family residences, and special Cold-s<strong>to</strong>rage buildings, single-family residences, and special- Cold-s<strong>to</strong>rage buildings, single-family residences, and special<br />

building use purpose facilities purpose facilities. purpose facilities<br />

18 Pre-construction notice and ERSystems must receive a completed warranty pre-notification ERSystems must receive a completed warranty pre-notification ERSystems must receive a completed warranty pre-notification<br />

approval requirements form prior <strong>to</strong> the start of the project. All warranty requests require form prior <strong>to</strong> the start of the project. All warranty requests require form prior <strong>to</strong> the start of the project. All warranty requests<br />

approval in advance of starting the project. Any deviations from approval in advance of starting the project. Any deviations from require approval in advance of starting the project. Any<br />

ER Systems' published specifications must be approved in writing ER Systems' published specifications must be approved in writing deviations from ER Systems' published specifications must be<br />

prior <strong>to</strong> job start prior <strong>to</strong> job start approved in writing prior <strong>to</strong> job start<br />

19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy ERSystems technical support representative makes inspections ERSystems technical support representative makes inspections<br />

during application depending on size and complexity of job and during application depending on size and complexity of job and<br />

qualifications of contrac<strong>to</strong>r, and after completion prior <strong>to</strong> issuance qualifications of contrac<strong>to</strong>r, and after completion prior <strong>to</strong> issuance<br />

of warranty as well as two years after issuance of warranty; no of warranty as well as two years after issuance of warranty; no<br />

charge for initial warranty; charge for subsequent inspection if job charge for initial warranty; charge for subsequent inspection if job<br />

does not pass inspection. ERSystems reserves the right <strong>to</strong> does not pass inspection. ERSystems reserves the right <strong>to</strong><br />

require a pre-job inspection<br />

require a pre-job inspection.<br />

21 Contrac<strong>to</strong>r’s post-installation The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship None; material-only warranty. None; material-only warranty.<br />

obligation<br />

deficiencies for two years<br />

ERSystems technical support representative makes inspections<br />

during application depending on size and complexity of job and<br />

qualifications of contrac<strong>to</strong>r, and after completion prior <strong>to</strong><br />

issuance of warranty as well as two years after issuance of<br />

warranty; no charge for initial warranty; charge for subsequent<br />

inspection if job does not pass inspection. ERSystems reserves<br />

the right <strong>to</strong> require a pre-job inspection<br />

22 Backed by named insurance No; ERSystems indicates that it carries a $2.5 million product No; ERSystems indicates that it carries a $2.5 million product No; ERSystems indicates that it carries a $2.5 million product<br />

or surety liability insurance covering its warranty obligations liability insurance covering its warranty obligations liability insurance covering its warranty obligations<br />

23 Issuing entity manufactures ERSystems sells product only. ERSystems sells product only ERSystems sells product only<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability The warranty is transferable subject <strong>to</strong> the terms of ERSystems' Warranty is transferable subject <strong>to</strong> the terms of ERSystems' The warranty is transferable subject <strong>to</strong> the terms of ERSystems'<br />

inspection, written approval, and payment of the current transfer inspection, written approval, and payment of the current transfer inspection, written approval, and payment of the current transfer<br />

fee, solely at the discretion of ERSystems. fee, solely at the discretion of ERSystems. fee, solely at the discretion of ERSystems<br />

26 Special features/condition If ERSystems determines the cause of a reported leak <strong>to</strong> be<br />

outside the scope of the warranty, inspection and repair costs shall<br />

be paid by the owner; failure of owner <strong>to</strong> pay for nonwarranted<br />

repairs within 30 days of notification shall render the warranty null<br />

and void.<br />

The warranty shall be governed and construed in accordance<br />

with the laws of the state of Minnesota. The courts of Minnesota<br />

shall have exclusive jurisdiction over all disputes arising out of<br />

warranty.<br />

Any action for breach of the contract or warranty, except for<br />

nonpayment by buyer, must be commenced within one year after<br />

the cause of action occurs, and all actions shall be barred after<br />

such time. Warranty states that it is agreed and unders<strong>to</strong>od that<br />

the price for the system is consideration for the limitation of<br />

ERSystems liability stated in warranty.<br />

If ERSystems determines the cause of a reported leak <strong>to</strong> be outside the<br />

scope of the warranty, inspection and repair costs shall be paid by the<br />

owner; failure of owner <strong>to</strong> pay for non-warranted repairs within 30 days of<br />

notification shall render the warranty null and void.<br />

The warranty shall be governed and construed in accordance with the<br />

laws of the state of Minnesota. The courts of Minnesota shall have<br />

exclusive jurisdiction over all disputes arising out of warranty.<br />

Any action for breach of the contract or warranty, except for nonpayment<br />

by buyer, must be commenced within one year after the cause of action<br />

occurs, and all actions shall be barred after such time. The warranty states<br />

that it is agreed and unders<strong>to</strong>od that the price for the system is<br />

consideration for the limitation of ERSystems liability stated in warranty.<br />

27 Executed by owner Yes Yes Yes<br />

If ERSystems determines the cause of a reported leak <strong>to</strong> be outside the<br />

scope of the warranty, inspection and repair costs shall be paid by the<br />

owner; failure of owner <strong>to</strong> pay for nonwarranted repairs within 30 days of<br />

notification shall render the warranty null and void.<br />

The warranty shall be governed and construed in accordance with the<br />

laws of the state of Minnesota. The courts of Minnesota shall have<br />

exclusive jurisdiction over all disputes arising out of warranty.<br />

Any action for breach of the contract or warranty, except for nonpayment<br />

by buyer, must be commenced within one year after the cause of action<br />

occurs, and all actions shall be barred after such time. Warranty states<br />

that it is agreed and unders<strong>to</strong>od that the price for the system is<br />

consideration for the limitation of ERSystems liability stated in warranty<br />

755


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity<br />

2 Title, original publication<br />

date, and identifying<br />

symbol, if any<br />

3 Product, specification, or<br />

system covered<br />

Fires<strong>to</strong>ne Building Products Company, Fires<strong>to</strong>ne Building Products Company, Fires<strong>to</strong>ne Building Products Company,<br />

division of Bridges<strong>to</strong>ne/Fires<strong>to</strong>ne, Inc. division of Bridges<strong>to</strong>ne/Fires<strong>to</strong>ne, Inc. division of Bridges<strong>to</strong>ne/Fires<strong>to</strong>ne, Inc.<br />

Fires<strong>to</strong>ne “Modified Bitumen Standard <strong>Roof</strong> System Limited Warranty;” Red Shield “<strong>Roof</strong>ing System Limited Warranty;” January, 1999; 1/99 - Item Rubbergard Max “Red Shield <strong>Roof</strong>ing System and Damage Repair<br />

January, 1996; 1/96-Item #558(R)MB (Replaces 7/94)-01 #902R (Replaces 4/96) Limited Warranty;” April, 2000; 4/00 - Item #1028R<br />

Fires<strong>to</strong>ne APP Systems, Fires<strong>to</strong>ne SBS Systems, Fires<strong>to</strong>ne BUR Systems Fires<strong>to</strong>ne APP, SBS, BUR, EPDM, Utraply PVC, Ultraply TPO Fires<strong>to</strong>ne Reinforced Max<br />

4 Scope of coverage Material and workmanship: Fires<strong>to</strong>ne warrants that it will repair any leak in Material and workmanship; Fires<strong>to</strong>ne warrants <strong>to</strong> repair any leak in the Material and Workmanship: Fires<strong>to</strong>ne warrants that it will repair any leak<br />

the Fires<strong>to</strong>ne modified bitumen roofing system that is not excluded by the Fires<strong>to</strong>ne roofing system that is not excluded by the terms of the warranty. in the Fires<strong>to</strong>ne roofing system, including repairing any leaks caused by<br />

terms of the warranty. (See Item 12 below). The Fires<strong>to</strong>ne System is (See Item 12 below). The Fires<strong>to</strong>ne roof system is limited <strong>to</strong> Fires<strong>to</strong>ne- unintentional and occasional damage <strong>to</strong> the membrane as a result of<br />

limited <strong>to</strong> mean Fires<strong>to</strong>ne-brand membranes, Fires<strong>to</strong>ne-brand insulation, brand membranes, Fires<strong>to</strong>ne-brand insulation, and other Fires<strong>to</strong>ne-brand roof-<strong>to</strong>p inspection, maintenance or service that is not excluded by the<br />

and other Fires<strong>to</strong>ne-brand accessories when installed in accordance with accessories when installed in accordance with Fires<strong>to</strong>ne technical terms of the warranty. The Fires<strong>to</strong>ne roofing system is limited <strong>to</strong> mean<br />

Fires<strong>to</strong>ne technical specifications. specifications. the Fires<strong>to</strong>ne-brand reinforced membranes, Fires<strong>to</strong>ne-brand insulations,<br />

and other Fires<strong>to</strong>ne-brand accessories when installed in accordance with<br />

Fires<strong>to</strong>ne technical specifications (See Item 12 below).<br />

5 Length of coverage 5, 10 or 12 years. Duration of warranty depends on the specification and 5, 10, 15 or 20 years. Duration of warranty depends on the specification 5, 10, 15, or 20 years. Duration of warranty depends on the specification<br />

materials used. and materials used. and materials used.<br />

6 Nature of remedy Owner’s sole and exclusive remedy and Fires<strong>to</strong>ne’s liability shall be limited Owner’s sole and exclusive remedy and Fires<strong>to</strong>ne’s liability shall be limited Owner’s sole and exclusive remedy and Fires<strong>to</strong>ne’s liability shall be<br />

<strong>to</strong> the repair of the leak. <strong>to</strong> the repair of the leak. limited <strong>to</strong> the repair of the leak.<br />

7 Monetary limitations Fires<strong>to</strong>ne’s repair obligation over the life of the warranty is limited <strong>to</strong> the None stated None stated<br />

original cost of the system installation.<br />

8 Notification requirements Written notice within 30 days of any occurrence of a leak. Written notice within 30 days of any occurrence of a leak Written notice within 30 days of any occurrence of a leak<br />

9 Exclusive or additional<br />

remedy<br />

10 Inclusion of consequential<br />

damages<br />

11 Determination of warranty<br />

applicability<br />

12 Specific exclusions from<br />

coverage (see Item 12 in<br />

Introduction)<br />

Warranty is owner’s sole and exclusive remedy against Fires<strong>to</strong>ne; warranty Warranty is owner’s sole and exclusive remedy against Fires<strong>to</strong>ne; warranty Warranty is owner’s sole and exclusive remedy against Fires<strong>to</strong>ne;<br />

supersedes and is in lieu of all other warranties or guarantees; excludes supersedes and is in lieu of all other warranties or guarantees; excludes warranty supersedes and is in lieu of all other warranties or guarantees;<br />

UCC warranties. UCC warranties. excludes UCC warranties.<br />

No No No<br />

Fires<strong>to</strong>ne’s determination Fires<strong>to</strong>ne’s determination Fires<strong>to</strong>ne’s determination<br />

1, 2, 3, 6, 7, 8, 10, 11, 12 (see Special Features/Conditions), 13, 17, 18, 22. 1, 2, 3, 6, 7, 8, 10, 12 (see Special Features/Conditions), 13, 17, 18, 22. 1, 2, 3, 6, 7, 8, 10, 12 (see Special Features/Conditions), 13, 17, 18, 22.<br />

Warranty also specifically excludes damages caused by a<strong>to</strong>mic radiation, Warranty also specifically excludes damages caused by a<strong>to</strong>mic radiation, Warranty also specifically excludes damages caused by a<strong>to</strong>mic radiation,<br />

insects, or animals and Specific Condition H. insects, or animals and Specific Condition H. insects, or animals and Specific Condition H.<br />

13 Wind coverage/exclusions Warranty excludes winds, hurricanes, and <strong>to</strong>rnadoes. Fires<strong>to</strong>ne indicates Warranty excludes winds in excess of 55 mph, hurricanes, and <strong>to</strong>rnadoes. Warranty excludes winds in excess of 55 mph, hurricanes and <strong>to</strong>rnadoes.<br />

that there is no coverage for damage caused by wind. Fires<strong>to</strong>ne indicates that warranty covers roof damage resulting from wind Fires<strong>to</strong>ne indicates that the warranty covers roof damage resulting from<br />

speeds up <strong>to</strong> 55 mph.<br />

wind speeds up <strong>to</strong> 55 miles per hour.<br />

14 Specific conditions <strong>to</strong><br />

make the warranty<br />

ineffective or null and void<br />

(see Item 14 Introduction)<br />

C, M, S (See Special Features/Conditions) C, M, S (See Special Features/Conditions) C, M, S (See Special Features/Conditions)<br />

15 Cost <strong>to</strong> obtain 5 years: $3.00/square; 10 years: $5.00/square; 12 years: $6.00/square 10 years: $4.00/square 10 years: $4.00/square<br />

16 Minimum charge 5 years: $300; 10 years: $350; 12 years: $400 5 years: $300; 10 years: $350; 15 years: $400; 20 years: $500 5 years: $300; 10 years: $350; 15 years: $400; 20 years: $500<br />

17 Ineligible structure or<br />

building use<br />

18 Pre-construction notice and<br />

approval requirements<br />

19 Approved, authorized, or<br />

licensed requirements<br />

Single-family residence, patio, plaza deck Single-family residence, patios, plaza decks Single-family residence, patios, plaza decks<br />

Preinstallation notice must be submitted 14 days prior <strong>to</strong> job start and must Preinstallation notice must be submitted 14 days prior <strong>to</strong> job start and must Preinstallation notice must be submitted 14 days prior <strong>to</strong> job start and<br />

be approved by Fires<strong>to</strong>ne technical service. be approved by Fires<strong>to</strong>ne technical service. must be approved by Fires<strong>to</strong>ne technical service.<br />

Yes Yes Yes<br />

756


20 Job inspection policy Fires<strong>to</strong>ne field technical representative makes on-site inspection during Fires<strong>to</strong>ne field technical representative makes on-site inspection during Fires<strong>to</strong>ne field technical representative makes on-site inspection during<br />

application when requested. Fires<strong>to</strong>ne field technical representative makes application when requested. Fires<strong>to</strong>ne field technical representative makes application when requested. Fires<strong>to</strong>ne field technical representative<br />

on-site inspection after job completion prior <strong>to</strong> issuance of warranty; no on-site inspection after job completion prior <strong>to</strong> issuance of warranty; no makes on-site inspection after job completion prior <strong>to</strong> issuance of<br />

charge. charge. warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation<br />

obligation<br />

22 Backed by named insurance<br />

or surety<br />

23 Issuing entity manufactures<br />

and/or sells products<br />

24 Conditions for renewal or<br />

extension<br />

Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for two Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for two Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for<br />

years. years. two years.<br />

No; Fires<strong>to</strong>ne indicates that it is self-insured. No; Fires<strong>to</strong>ne indicates that it is self-insured. No; Fires<strong>to</strong>ne indicates that it is self-insured.<br />

Fires<strong>to</strong>ne manufactures and sells the product. Fires<strong>to</strong>ne manufactures and sells the product. Fires<strong>to</strong>ne manufactures and sells the product.<br />

No renewal provision Warranty can be extended for 5 years at a charge of $10.00/square or Warranty can be extended for 5 years at a charge of $10.00/square or<br />

$2.00/square if coated with Fires<strong>to</strong>ne AcryliTop. Owner pays $750 for $2.00/square if coated with Fires<strong>to</strong>ne AcryliTop.<br />

inspection.<br />

25 Assignability Warranty is transferable subject <strong>to</strong> Fires<strong>to</strong>ne inspection, written approval, Warranty is transferable subject <strong>to</strong> Fires<strong>to</strong>ne inspection, written approval, Warranty is transferable subject <strong>to</strong> Fires<strong>to</strong>ne inspection, written approval,<br />

and payment of current transfer fee. and payment of current transfer fee. and payment of current transfer fee.<br />

26 Special features/condition If Fires<strong>to</strong>ne’s investigation reveals that the cause of a leak is excluded If Fires<strong>to</strong>ne’s investigation reveals that the cause of a leak is excluded If Fires<strong>to</strong>ne’s investigation reveals that the cause of a leak is excluded<br />

under the warranty, investigation costs shall be paid by owner; failure of under the warranty, investigation costs shall be paid by owner; failure of under the warranty, investigation costs shall be paid by owner; failure of<br />

owner <strong>to</strong> pay these costs shall render the warranty null and void. Any owner <strong>to</strong> pay these costs shall render the warranty null and void. Fires<strong>to</strong>ne owner <strong>to</strong> pay these costs shall render the warranty null and void. Any<br />

dispute, controversy or claim between the owner and Fires<strong>to</strong>ne concerning will advise the owner of the type and/or extent of repairs required <strong>to</strong> be dispute, controversy or claim between the owner and Fires<strong>to</strong>ne<br />

the warranty shall be settled by final and binding arbitration in accordance made at the owner’s expense that will permit the warranty <strong>to</strong> remain in effect concerning the warranty shall be settled by mediation. The owner and<br />

with the American Arbitration <strong>Association</strong>’s rules for the construction for the unexpired portion of its term. Failure by the owner <strong>to</strong> properly make Fires<strong>to</strong>ne agree that neither party will commence or prosecute any suit,<br />

industry. Warranty shall be governed and construed in accordance with the these repairs in a reasonable manner using a Fires<strong>to</strong>ne Licensed Applica<strong>to</strong>r proceeding or claim other than in the courts of Hamil<strong>to</strong>n County in the<br />

laws of the state of Indiana without regard <strong>to</strong> conflict of laws. and within a reasonable time shall render the warranty null and void. Any State of Indiana or the United States District Court, Southern District of<br />

Fires<strong>to</strong>ne does not undertake any analysis of the architecture or dispute, controversy or claim between the owner and Fires<strong>to</strong>ne concerning Indiana, Indianapolis Division. Each party irrevocably consents <strong>to</strong> the<br />

engineering required <strong>to</strong> evaluate what type of roof system is appropriate. the warranty shall be settled by final and binding arbitration in accordance jurisdiction and venue of the above-identified courts. Warranty shall be<br />

Warranty cannot be amended, altered, or modified in any way except in with the Canadian Arbitration <strong>Association</strong>’s rules for the construction governed and construed in accordance with the laws of the State of<br />

writing signed by the president of Fires<strong>to</strong>ne or a person <strong>to</strong> whom his industry. Warranty shall be governed and construed in accordance with the Indiana without regard <strong>to</strong> conflict of laws.<br />

authority has been delegated in writing<br />

laws of the State of Indiana without regard <strong>to</strong> conflict of laws. Fires<strong>to</strong>ne does not undertake any analysis of the architecture or<br />

Warranty requires owner’s compliance with Fires<strong>to</strong>ne roofing care and Fires<strong>to</strong>ne does not undertake any analysis of the architecture or engineering required <strong>to</strong> evaluate what type of roof system is appropriate.<br />

maintenance requirements stated on reverse side of warranty document, engineering required <strong>to</strong> evaluate what type of roof system is appropriate. Warranty cannot be amended, altered, or modified in any way except in<br />

including at least twice yearly inspections; ponding water not be allowed; Warranty cannot be amended, altered, or modified in any way except in writing signed by the president of Fires<strong>to</strong>ne or a person <strong>to</strong> whom his<br />

drain areas remain clear; no exposure <strong>to</strong> acids, solvents, greases, oil, fats, writing signed by the president of Fires<strong>to</strong>ne or a person <strong>to</strong> whom his authority has been delegated in writing.<br />

chemicals, and the like; protective walkways for roof traffic; maintenance of authority has been delegated in writing. Warranty requires owner’s compliance with Fires<strong>to</strong>ne roofing care and<br />

counter flashings, metal work, drains, skylights, equipment curbs and<br />

Warranty requires owner’s compliance with Fires<strong>to</strong>ne roofing care and maintenance requirements stated on reverse side of warranty document,<br />

supports, other roof<strong>to</strong>p accessories, and roof coatings and sealants. maintenance requirements stated on reverse side of warranty document, including at least twice yearly inspections; ponding water not be allowed;<br />

In the event roof access is limited due <strong>to</strong> security or other restrictions, including at least twice yearly inspections; ponding water not be allowed; drain areas remain clear; no exposure <strong>to</strong> acids, solvents, greases, oil,<br />

the owner shall reimburse Fires<strong>to</strong>ne for all reasonable costs incurred during drain areas remain clear; no exposure <strong>to</strong> acids, solvents, greases, oil, fats, fats, chemicals, and the like; protective walkways for roof traffic;<br />

inspection and/or repair of the system which are due <strong>to</strong> delays associated chemicals, and the like; protective walkways for roof traffic; maintenance of maintenance of counter flashings, metal work, drains, skylights,<br />

with said restrictions. The owner shall be responsible for the removal and counter flashings, metal work, drains, skylights, equipment curbs and equipment curbs and supports, other roof<strong>to</strong>p accessories.<br />

replacement of any overburdens, superstrata or overlays, either permanent supports, other roof<strong>to</strong>p accessories, and roof coatings and sealants. In the event the roof access is limited due <strong>to</strong> security or other<br />

or temporary, as necessary <strong>to</strong> expose the system for inspection and/or In the event the roof access is limited due <strong>to</strong> security or other restrictions, restrictions, the owner shall reimburse Fires<strong>to</strong>ne for all reasonable costs<br />

repair.<br />

the owner shall reimburse Fires<strong>to</strong>ne for all reasonable costs incurred during incurred during inspection and/or repair of the system which are due <strong>to</strong><br />

inspection and/or repair of the system which are due <strong>to</strong> delays associated delays associated with said restrictions. The owner shall be responsible<br />

with said restrictions. The owner shall be responsible for the removal and for the removal and replacement of any overburdens, superstrata or<br />

replacement of any overburdens, superstrata or overlays, either permanent overlays, either permanent or temporary, as necessary <strong>to</strong> expose the<br />

or temporary, as necessary <strong>to</strong> expose the system for inspection and/or system for inspection and/or repair.<br />

repair. As a special term of this warranty, Fires<strong>to</strong>ne will repair any leaks<br />

caused by unintentional and occasional damage <strong>to</strong> the membrane as a<br />

result of roof-<strong>to</strong>p inspection, maintenance or service.<br />

27 Executed by owner No No No<br />

757


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity<br />

Fires<strong>to</strong>ne Building Products Company,<br />

division of Bridges<strong>to</strong>ne/Fires<strong>to</strong>ne Inc.<br />

2 Title, original publication Fires<strong>to</strong>ne “Modified Bitumen Product Limited Warranty”;<br />

date, and identifying symbol, September 1997; 9/97 Item #913MB (Replaced 2/96)-01<br />

if any<br />

3 Product, specification, or Fires<strong>to</strong>ne APP 160, 170, 180, Fires<strong>to</strong>ne SBS<br />

system covered<br />

4 Scope of coverage Material only; Fires<strong>to</strong>ne warrants that it will provide replacement<br />

membrane material or a prorated credit (based upon the<br />

remaining months of the unexpired warranty) sufficient <strong>to</strong> replace<br />

any area of Fires<strong>to</strong>ne modified bitumen membrane that leaks as a<br />

result of ordinary exposure <strong>to</strong> the elements or any manufacturing<br />

defect in the membrane. Warranty does not cover flashings,<br />

seams, adhesives, sealants, coatings, or workmanship<br />

5 Length of coverage 10 years: Fires<strong>to</strong>ne APP 160 or 170 (smooth surfaced), Fires<strong>to</strong>ne<br />

SBS (granule surfaced); 12 years: Fires<strong>to</strong>ne APP 160 or 170<br />

(smooth surfaced) with approved field-applied roof coating,<br />

Fires<strong>to</strong>ne APP 180 (granule surfaced), Fires<strong>to</strong>ne SBS (granule<br />

surfaced) installed over a hot asphalt attached base sheet<br />

6 Nature of remedy Purchaser's sole and exclusive remedy and Fires<strong>to</strong>ne's liability<br />

shall be limited either <strong>to</strong> the supply of replacement membrane<br />

material sufficient <strong>to</strong> cover or replace the deteriorated membrane<br />

area or a prorated credit (based on the number of remaining<br />

months of the unexpired warranty) <strong>to</strong> be applied <strong>to</strong>wards the<br />

purchase of the new membrane material<br />

7 Monetary limitations Fires<strong>to</strong>ne's replacement obligations over the life of the warranty<br />

are limited <strong>to</strong> the original cost of the membrane.<br />

Fires<strong>to</strong>ne Building Products Company,<br />

division of Bridges<strong>to</strong>ne/Fires<strong>to</strong>ne Inc.<br />

Fires<strong>to</strong>ne Building Products Company,<br />

division of Bridges<strong>to</strong>ne/Fires<strong>to</strong>ne Inc.<br />

Fires<strong>to</strong>ne "Modified Bitumen Membrane Limited Warranty;" November 1997; Fires<strong>to</strong>ne “White AcryliTop PC-100 Surface Reflectance Limited<br />

11/97 Item # 595(R)MB (Replaces 7/94)-01 Warranty;” April, 2000; 4/00 - Item #1027R<br />

Fires<strong>to</strong>ne APP, Fires<strong>to</strong>ne SBS<br />

Material only; Fires<strong>to</strong>ne warrants that it will repair any leak caused by<br />

weathering of the Fires<strong>to</strong>ne modified bitumen roofing membrane as a result<br />

of ordinary exposure <strong>to</strong> the elements or any manufacturing defect in the<br />

membrane. Warranty does not cover flashings, seams, adhesives, sealant,<br />

coatings, or workmanship.<br />

5, 10, or 12 years 5 years<br />

The owner's sole and exclusive remedy and Fires<strong>to</strong>ne's liability shall be<br />

limited <strong>to</strong> the repair of the leak.<br />

Fires<strong>to</strong>ne's repair obligations over the life of the warranty are limited <strong>to</strong> the<br />

original cost of the membrane installation.<br />

Fires<strong>to</strong>ne AcryliTop PC-100 coating applied <strong>to</strong> Fires<strong>to</strong>ne EPDM<br />

Membrane<br />

Material only: Fires<strong>to</strong>ne warrants that the AcryliTop PC-100 white<br />

coating applied <strong>to</strong> the Fires<strong>to</strong>ne RubberGard Membrane will not fall<br />

below a minimum reflectance rating of .50 due <strong>to</strong> ordinary exposure <strong>to</strong> the<br />

elements when tested in accordance with the Environmental Protection<br />

Agency’s “Energy Star” program.<br />

Owner’s sole and exclusive remedy and Fires<strong>to</strong>ne’s liability shall be<br />

limited <strong>to</strong> the supply of replacement AcryliTop PC-100 material sufficient<br />

<strong>to</strong> replace the affected area of coating.<br />

None stated<br />

8 Notification requirements Written notification within 30 days of any occurrence of a leak Written notification within 30 days of any occurrence of a leak Written notice within 30 days of any claim under the warranty<br />

9 Exclusive or additional The warranty is purchaser's sole and exclusive remedy against<br />

remedy<br />

Fires<strong>to</strong>ne; warranty supersedes and is in lieu of all other<br />

warranties or guarantees; excludes UCC warranties.<br />

10 Inclusion of consequential No<br />

damages<br />

11 Determination of warranty Fires<strong>to</strong>ne's determination<br />

applicability<br />

Warranty is owner's sole and exclusive remedy against Fires<strong>to</strong>ne; warranty<br />

supersedes and is in lieu of all other warranties or guarantees; excludes<br />

UCC warranties.<br />

No<br />

Fires<strong>to</strong>ne's determination<br />

Warranty is owner’s sole and exclusive remedy against Fires<strong>to</strong>ne;<br />

warranty supersedes and is in lieu of all other warranties or guarantees;<br />

excludes UCC warranties.<br />

No<br />

Reflectance testing <strong>to</strong> be completed at Owner’s expense by an<br />

independent testing labora<strong>to</strong>ry using equipment specified in warranty;<br />

warranty also states Fires<strong>to</strong>ne determines whether the reflective value is<br />

below .50 as a result of ordinary exposure <strong>to</strong> the elements.<br />

12 Specific exclusions from 1, 2, 3, 6, 7, 8, 10, 11, 12 (see Special Features/Conditions), 13,<br />

coverage (see Item 12 in<br />

Introduction)<br />

17, 18, 22. The warranty also specifically excludes damages<br />

caused by a<strong>to</strong>mic radiation, insects, or animals, and Specific<br />

Condition<br />

13 Wind coverage/exclusions The warranty excludes winds, hurricanes, and <strong>to</strong>rnadoes.<br />

Fires<strong>to</strong>ne indicates that there is no coverage for damage caused<br />

by wind.<br />

14 Specific conditions <strong>to</strong> make M, S (See Special Features/Conditions.)M, S (See Special<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

Features/Conditions.)<br />

1, 2, 3, 6, 7, 8, 10, 12 (see Special Features/Conditions), 13, 17, 18, 22. 1, 2, 3, 8, 11, 12 (see Special Features/Conditions), 13, 17, 18, 19.<br />

Warranty also specifically excludes damages caused by a<strong>to</strong>mic radiation, Warranty also specifically excludes damages caused by a<strong>to</strong>mic radiation,<br />

insects, or animals and Specific Condition H. insects, or animals and Specific Condition H.<br />

Warranty excludes winds in excess of 55 mph, hurricanes, and <strong>to</strong>rnadoes. Warranty excludes winds, hurricanes, and <strong>to</strong>rnadoes. Fires<strong>to</strong>ne indicates<br />

Fires<strong>to</strong>ne indicates that warranty covers roof damage resulting from wind that there is no coverage for damages caused by wind.<br />

speeds up <strong>to</strong> 55 mph<br />

C, M, S (See Special Features Conditions.) C, F, H, J, M, O (See Special Features/Conditions)<br />

758


15 Cost <strong>to</strong> obtain None Fires<strong>to</strong>ne EPDM: 5 years: $3.00/square; 10 years: $5.00/square; 15 years: $8.00/<br />

square; 20 years: $10.00/square; (warranty price is reduced $1.00/square for using<br />

nonreinforced membrane with the exception of 20-year term.)<br />

UltraPly: 5 years: $3.00/square; 10 years: $5.00/square; 15 years: $8.00/square;<br />

Fires<strong>to</strong>ne APP (without roof moni<strong>to</strong>ring): 5 years: $3.00/square; 10 years:<br />

$7.00/square; 12 years: $9.00/square; 15 years: $12.00/square; 20 years:<br />

$17.00/square;<br />

Fires<strong>to</strong>ne SBS (without roof moni<strong>to</strong>ring): 5 years: $3.00/square; 10 years:<br />

$7.00/square; 12 years: $9.00/square; 15 years: $12.00/square; 20<br />

years:$17.00/square;<br />

Fires<strong>to</strong>ne Built-up (without roof moni<strong>to</strong>ring): 5 years: $3.00/square; 10 years:<br />

$7.00/square; 12 years: $9.00/square; 15 years: $12.00/square; 20 years:<br />

$17.00/square; (warranty price for APP, SBS, and built-up systems are reduced<br />

when roof moni<strong>to</strong>ring is employed<br />

$200<br />

16 Minimum charge None Varies from $250 <strong>to</strong> $750 depending on length of coverage $200<br />

17 Ineligible structure or Single-family residence, patio, plaza deck, roofs outside of U.S.<br />

building use<br />

and Canada<br />

18 Pre-construction notice and None required.<br />

approval requirements<br />

19 Approved, authorized, or No<br />

licensed requirements<br />

Single-family residence, patio, plaza deck, roofs outside of U.S. and Canada<br />

Preinstallation notice must be submitted 14 days prior <strong>to</strong> job start and must<br />

be approved by Fires<strong>to</strong>ne technical service<br />

Yes<br />

Single-family residence, patio, plaza deck<br />

Preinstallation notice must be submitted 14 days prior <strong>to</strong> job start and<br />

must be approved by Fires<strong>to</strong>ne technical service.<br />

Yes<br />

20 Job inspection policy No on-site inspections Fires<strong>to</strong>ne field technical representative makes on-site inspection after<br />

completion and prior <strong>to</strong> issuance of warranty; no charge<br />

Fires<strong>to</strong>ne field technical representative makes on-site inspection during<br />

application when requested. Fires<strong>to</strong>ne field technical representative makes onsite<br />

inspection after job completion prior <strong>to</strong> issuance of warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation None required<br />

obligation<br />

22 Backed by named insurance No; Fires<strong>to</strong>ne indicates that it is self-insured<br />

or surety<br />

23 Issuing entity manufactures Fires<strong>to</strong>ne manufactures and sells the product.<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision<br />

extension<br />

25 Assignability Warranty is transferable subject <strong>to</strong> Fires<strong>to</strong>ne inspection, written<br />

approval, and payment of current transfer fee.<br />

Contrac<strong>to</strong>r obligated <strong>to</strong> repair workmanship deficiencies for two years.<br />

No; Fires<strong>to</strong>ne indicates that it is self-insured.<br />

Fires<strong>to</strong>ne manufactures and sells the product.<br />

No renewal provision<br />

Warranty is transferable subject <strong>to</strong> Fires<strong>to</strong>ne inspection, written approval,<br />

and payment of current transfer fee.<br />

Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for<br />

two years<br />

No; Fires<strong>to</strong>ne indicates that it is self-insured.<br />

Fires<strong>to</strong>ne does not indicate whether they manufacture or sell the product.<br />

Warranty can be extended for 5 years for a charge of $2.00/square.<br />

Warranty is transferable subject <strong>to</strong> Fires<strong>to</strong>ne inspection, written approval,<br />

and payment of current transfer fee.<br />

26 Special features/condition If Fires<strong>to</strong>ne's investigation reveals that the cause of a leak is outside the If Fires<strong>to</strong>ne's investigation reveals that the cause of a leak is excluded If Fires<strong>to</strong>ne determines that the reflectance value of coating below .50 is<br />

scope of the warranty, investigation costs shall be paid by purchaser; failure under the warranty, investigation costs shall be paid by owner; failure of caused by something other than ordinary exposure <strong>to</strong> the elements,<br />

of purchaser <strong>to</strong> pay these costs shall render the warranty null and void. Any owner <strong>to</strong> pay these costs shall render the warranty null and void. Any investigation costs must be paid by the owner; failure of owner <strong>to</strong> pay<br />

dispute, controversy, or claim between the purchaser and Fires<strong>to</strong>ne dispute, controversy, or claim between the owner and Fires<strong>to</strong>ne concerning these costs shall render the warranty null and void. Any dispute,<br />

concerning warranty shall be settled by final and binding arbitration in warranty shall be settled by final and binding arbitration in accordance with controversy or claim between the owner and Fires<strong>to</strong>ne concerning<br />

accordance with the American Arbitration <strong>Association</strong>'s rules for the the American Arbitration <strong>Association</strong>'s rules for the construction industry. warranty shall be settled by mediation. The owner and Fires<strong>to</strong>ne agree<br />

construction industry. Warranty shall be governed and construed in Warranty shall be governed and construed in accordance with the laws of that neither party will commence or prosecute any suit, proceeding or<br />

accordance with the laws of the state of Ind. without regard <strong>to</strong> conflict the state of Indiana without regard <strong>to</strong> conflict of laws. claim other than in the courts of Hamil<strong>to</strong>n County in the State of Indiana<br />

and/or repair. of laws. Fires<strong>to</strong>ne does not undertake any analysis of the architecture or or the United States District Court, Southern District of Indiana,<br />

Fires<strong>to</strong>ne does not undertake any analysis of the architecture or engineering required <strong>to</strong> evaluate what type of roof system is appropriate. Indianapolis Division. Each party irrevocably consents <strong>to</strong> the jurisdiction<br />

engineering required <strong>to</strong> evaluate what type of roof system is appropriate. Warranty cannot be amended, altered, or modified in any way except in and venue of the above-identified courts. Warranty shall be governed<br />

Warranty cannot be amended, altered, or modified in any way except in writing signed by the president of Fires<strong>to</strong>ne or a person <strong>to</strong> whom his and construed in accordance with the laws of the State of Indiana without<br />

writing signed by the president of Fires<strong>to</strong>ne or a person <strong>to</strong> whom his authority has been delegated in writing. regard <strong>to</strong> conflict of laws.<br />

authority has been delegated in writing. Warranty requires owner compliance with Fires<strong>to</strong>ne roofing care and Warranty cannot be amended, altered, or modified in any way except<br />

Warranty requires purchaser compliance with Fires<strong>to</strong>ne roofing care and maintenance requirements stated on reverse side of warranty document, in writing signed by the president of Fires<strong>to</strong>ne or a person <strong>to</strong> whom his<br />

maintenance requirements stated on reverse side of warranty document, including at least twice yearly inspections; ponding water not be allowed; authority has been delegated in writing.<br />

including at least twice yearly inspections; ponding water not be allowed; drain areas remain clear; no exposure <strong>to</strong> acids, solvents, greases, oil, fats, Warranty requires owner’s compliance with Fires<strong>to</strong>ne roofing care and<br />

drain areas remain clear; no exposure <strong>to</strong> acids, solvents, greases, oil, fats, chemicals, and the like; protective walkways for roof traffic; maintenance of maintenance requirements stated on reverse side of warranty document,<br />

chemicals, and the like; protective walkways for roof traffic; maintenance of counter flashings, metal work, drains, skylights, equipment curbs and including no exposure <strong>to</strong> acids, solvents, greases, oils, fats, chemicals<br />

counter flashings, metal work, drains, skylights, equipment curbs and supports, other roof<strong>to</strong>p accessories, and roof coatings and sealants. and the like; and verification that the PC-100 coating remains intact<br />

supports, other roof<strong>to</strong>p accessories, and roof coatings and sealants. In the event the roof access is limited due <strong>to</strong> security or other restrictions, where water may pond for more than 48 hours or where there is<br />

In the event the roof access is limited due <strong>to</strong> security or other restrictions, the owner shall reimburse Fires<strong>to</strong>ne for all reasonable costs incurred during occasional traffic on the roof surface. The warranty does not cover the<br />

purchaser shall reimburse Fires<strong>to</strong>ne for all reasonable costs incurred during inspection and/or repair of the system that are due <strong>to</strong> delays associated with coating in areas where there is ponding water or where the coating has<br />

inspection and/or repair of the system which are due <strong>to</strong> delays associated said restrictions. The owner shall be responsible for the removal and been worn away or damaged by traffic.<br />

with said restrictions. Purchaser shall be responsible for the removal and replacement of any overburdens, superstrata or overlays, either permanent In the event that roof access is limited due <strong>to</strong> security or other<br />

replacement of any overburdens, superstrata or overlays, either permanent or temporary, excluding accepted s<strong>to</strong>ne ballast or pavers, as necessary <strong>to</strong> restrictions, owner shall reimburse Fires<strong>to</strong>ne for all reasonable costs<br />

or temporary, as necessary <strong>to</strong> expose the surface of the membrane for expose the system for inspection and/or repair. incurred during inspection and/or repair of the system which are due <strong>to</strong><br />

inspection delays associated with said restrictions. Failure by owner <strong>to</strong> pay these<br />

costs or <strong>to</strong> deny roof access <strong>to</strong> Fires<strong>to</strong>ne shall render the warranty null<br />

and void until such costs are paid in full.<br />

27 Executed by owner No No No<br />

759


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

Fires<strong>to</strong>ne Building Products Company,<br />

Fires<strong>to</strong>ne Building Products Company,<br />

1 Identity of issuing entity Flex Membrane International<br />

division of Bridges<strong>to</strong>ne/Fires<strong>to</strong>ne, Inc.<br />

division of Bridges<strong>to</strong>ne/Fires<strong>to</strong>ne, Inc.<br />

2 Title, original publication "Manufacturer's Insulation Warranty"; 4/96 - Item #953S-01 Fires<strong>to</strong>ne <strong>Roof</strong>ing Membrane Limited Warranty; December “Warranty”; July 1990<br />

date, and identifying 1996; 12/96 Item #812R (Replaces 8/94)-01<br />

symbol, if any<br />

3 Product, specification, or Fires<strong>to</strong>ne ISO 95+ insulation Fires<strong>to</strong>ne Rubbergard EPDM, Fires<strong>to</strong>ne Ultra Ply 78+ Flex FB Elvaloy, Flex MF/R Elvaloy, Flex MF/R 50, Flex<br />

system covered MF/R 60, Flex MF/R 70, Flex MF/R 80, Flex FB 100<br />

4 Scope of coverage Material only; Fires<strong>to</strong>ne warrants that when used under a Material only; Fires<strong>to</strong>ne warrants that it will provide Material and workmanship; Flex warrants against leakage<br />

Fires<strong>to</strong>ne-manufactured roofing membrane, the Fires<strong>to</strong>ne replacement membrane materials sufficient <strong>to</strong> replace any caused by defects in Flex materials or workmanship in the<br />

ISO 95+ will not warp, bow, or destablize <strong>to</strong> the point of area of Fires<strong>to</strong>ne roofing membrane that leaks as a result of application of Flex's material.<br />

causing a roof leak as a result of any manufacturing defect in ordinary exposure <strong>to</strong> the elements or any manufacturing<br />

the ISO 95+. This warranty is only effective when issued with defect in the membrane. Warranty does not cover flashings,<br />

a Fires<strong>to</strong>ne Standard or Red Shield System warranty seams, adhesives, sealants, coatings, or workmanship.<br />

5 Length of coverage 10, 15, or 20 years [Fires<strong>to</strong>ne indicates term of insulation Fires<strong>to</strong>ne Ultra Ply 78+; 20 years: Fires<strong>to</strong>ne EPDM 5, 10, or 15 years<br />

warranty cannot exceed that of the standard or Red Shield Up <strong>to</strong> 20 years: Ultraply TPO<br />

Term.]<br />

6 Nature of remedy Fires<strong>to</strong>ne shall provide the owner with free Fires<strong>to</strong>ne ISO 95+ Fires<strong>to</strong>ne's liability shall be limited <strong>to</strong> providing replacement Flex's sole obligation shall be <strong>to</strong> repair any leaks in the roof<br />

and Fires<strong>to</strong>ne roofing membrane materials and shall repair the membrane material <strong>to</strong> any area that leaks as a result of caused by defects in Flex materials or workmanship of the<br />

affected roof area deterioration. roofing contrac<strong>to</strong>r in the application of Flex's material.<br />

7 Monetary limitations None stated Fires<strong>to</strong>ne's repair obligations over the life of the warranty are None stated<br />

limited <strong>to</strong> the original cost of the membrane installation.<br />

8 Notification requirements Written notification within 30 days of the discovery of any Written notification within 30 days of any occurrence of a leak. Written notification <strong>to</strong> Flex Membrane International,<br />

event leading <strong>to</strong> a claim.<br />

Bethlehem Drive, Morgan<strong>to</strong>wn, PA 19543, by registered<br />

mail within 30 days of discovery of any defect in Flex<br />

material<br />

9 Exclusive or additional The warranty is the owner's sole and exclusive remedy against The warranty is owner's sole and exclusive remedy against Warranty supersedes and is in lieu of any and all other<br />

remedy Fires<strong>to</strong>ne; the warranty supersedes and is in lieu of all other Fires<strong>to</strong>ne; warranty supersedes and is in lieu of all other express warranties that conflict with the terms and<br />

warranties or guarantees; Fires<strong>to</strong>ne shall not be liable for any warranties or guarantees; excludes UCC warranties. conditions stated in the warranty.<br />

damages that are based on negligence, breach of warranty,<br />

strict liability, or any other theory, other than the limited liability<br />

set forth in the warranty; excludes UCC warranties<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Fires<strong>to</strong>ne's determination Fires<strong>to</strong>ne's determination Flex's judgement<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 6, 7, 10, 12, 13, 18, 22. The warranty also specifically 1, 2, 3, 6, 7, 8, 10, 12, 17, 18, 22. The warranty also 1 , 2, 3, 4, 5, 16<br />

coverage (see Item 12 in excludes damages caused by a<strong>to</strong>mic radiation, insects, or specifically excludes damages caused by a<strong>to</strong>mic radiation,<br />

Introduction) animals insects, or animals, and Specific Condition H.<br />

13 Wind coverage/exclusions The warranty excludes winds, hurricanes, and <strong>to</strong>rnadoes. The warranty excludes winds, hurricanes, and <strong>to</strong>rnadoes. Warranty excludes hurricanes and <strong>to</strong>rnadoes. Flex<br />

Fires<strong>to</strong>ne indicates that there is no coverage for damages Fires<strong>to</strong>ne indicates that there is no coverage for damage indicates that warranty covers wind speeds up <strong>to</strong> 60 mph.<br />

caused by wind.<br />

caused by wind.<br />

14 Specific conditions <strong>to</strong> J M, S (See Special Features/Conditions.) B, C, F, G, H<br />

make the warranty<br />

ineffective or null and void<br />

(see Item 14 in<br />

Introduction)<br />

760


15 Cost <strong>to</strong> obtain None $200 5 years: None; 10 years: $5.00/square; 15 years:<br />

8.00/square<br />

16 Minimum charge None $200 5 years: None; 10 years: $375;15 years: $600<br />

17 Ineligible structure or<br />

building use<br />

18 Pre-construction notice<br />

and approval requirements<br />

19 Approved, authorized, or<br />

licensed requirements<br />

Single-family residence, patio, plaza deck, roofs outside of Single-family residence, patio, plaza deck, roofs outside of None<br />

U.S. and Canada<br />

U.S. and Canada.<br />

Preinstallation notice must be submitted 14 days prior <strong>to</strong> job Preinstallation notice must be submitted 14 days prior <strong>to</strong> job The contrac<strong>to</strong>r submits request for guarantee <strong>to</strong> Flex for<br />

start and must be approved by Fires<strong>to</strong>ne technical service. start. approval with roof diagram.<br />

Yes No Yes<br />

20 Job inspection policy Fires<strong>to</strong>ne field technical representative makes on-site No on-site inspections Flex technical representative makes on-site inspections<br />

inspection after job completion prior <strong>to</strong> issuance of warranty;<br />

prior <strong>to</strong>, during application (a minimum of one inspection),<br />

no charge.<br />

and after completion of installation prior <strong>to</strong> issuance of<br />

warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s postinstallation<br />

obligation<br />

22 Backed by named<br />

insurance or surety<br />

23 Issuing entity<br />

manufactures and/or sells<br />

products<br />

24 Conditions for renewal or<br />

extension<br />

Although this is a material-only warranty, the contrac<strong>to</strong>r is Although this is a material-only warranty, the contrac<strong>to</strong>r is The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> all leaks and<br />

obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for two obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for two workmanship deficiencies for two years<br />

years.<br />

years.<br />

No; Fires<strong>to</strong>ne indicates that it is self-insured No; Fires<strong>to</strong>ne indicates that it is self-insured No; Flex indicates that it does not carry insurance covering<br />

its warranty obligations<br />

Fires<strong>to</strong>ne manufactures and sells the product. Fires<strong>to</strong>ne manufactures and sells the product. Flex manufactures and sells the product<br />

No renewal provision No renewal provision No renewal provision in warranty. Flex indicates that it may<br />

issue extensions on an individual project basis.<br />

25 Assignability No restrictions stated. Warranty is transferable subject <strong>to</strong> Fires<strong>to</strong>ne inspection, Warranty may not be transferred without the written consent<br />

written approval, and payment of current transfer fee. of Flex. Flex indicates it permits transfer with written<br />

consent from Flex and payment of transfer fee.<br />

26 Special features/condition Fires<strong>to</strong>ne does not undertake any analysis of the architecture<br />

or engineering required <strong>to</strong> evaluate what type of roof system is<br />

appropriate.<br />

Warranty requires compliance with Fires<strong>to</strong>ne roofing care<br />

and maintenance requirements stated on reverse side of<br />

warranty, including at least twice yearly inspections; ponding<br />

water not allowed; drain areas remain clear; no exposure <strong>to</strong><br />

acids, solvents, greases, oils, fats, chemicals and the like.<br />

Contact Fires<strong>to</strong>ne immediately if the Fires<strong>to</strong>ne <strong>Roof</strong>ing<br />

System comes in<strong>to</strong> contact with any such materials<br />

If Fires<strong>to</strong>ne's investigation reveals that the cause of a leak is outside the<br />

scope of the warranty, investigation costs shall be paid by purchaser; failure<br />

of purchaser <strong>to</strong> pay these costs shall render the warranty null and void. Any<br />

dispute, controversy, or claim between the purchaser and Fires<strong>to</strong>ne<br />

concerning warranty shall be settled by final and binding arbitration in<br />

accordance with the American Arbitration <strong>Association</strong>'s rules for the<br />

construction industry. Warranty shall be governed and construed in<br />

accordance with the laws of the state of Indiana without regard <strong>to</strong> conflict of<br />

laws.<br />

Fires<strong>to</strong>ne does not undertake any analysis of the architecture or<br />

engineering required <strong>to</strong> evaluate what type of roof system is appropriate.<br />

Warranty cannot be amended, altered, or modified in any way except in<br />

writing signed by the president of Fires<strong>to</strong>ne or a person <strong>to</strong> whom his<br />

authority has been delegated in writing.<br />

Warranty requires purchaser compliance with Fires<strong>to</strong>ne roofing care and<br />

maintenance requirements stated on reverse side of warranty document,<br />

including at least twice yearly inspections; ponding water not be allowed;<br />

drain areas remain clear; no exposure <strong>to</strong> acids, solvents, greases, oil, fats,<br />

chemicals, and the like; protective walkways for roof traffic; maintenance of<br />

counter flashings, metal work, drains, skylights, equipment curbs and<br />

supports, other roof<strong>to</strong>p accessories, and roof coatings and sealants.<br />

In the event the roof access is limited due <strong>to</strong> security or other restrictions,<br />

purchaser shall reimburse Fires<strong>to</strong>ne for all reasonable costs incurred during<br />

inspection and/or repair of the system which are due <strong>to</strong> delays associated<br />

with said restrictions. Purchaser shall be responsible for the removal and<br />

replacement of any overburdens, superstrata or overlays, either permanent<br />

or temporary, as necessary <strong>to</strong> expose the surface of the membrane for<br />

inspection and/or repair.<br />

27 Executed by owner No No No<br />

No representative of Flex has authority <strong>to</strong> make any representations or<br />

promises except as stated in warranty.<br />

761


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Flex Membrane International GAF Materials Corporation (GAF) GAF Materials Corporation (GAF)<br />

2 Title, original publication Membrane Material Warranty; July 1990 Limited Warranty on Material GAFGLAS; March 1994, Form "EverGuard Gold Seal Guarantee;" January 1998; Form 10510<br />

date, and identifying symbol, 10450 3/94 1/98<br />

if any<br />

3 Product, specification, or Flex membrane material in all Flex roof systems GAFGLAS Ply 6, GAFGLAS Ply 4 and all GAF BUR specifications EverGuard Single-Ply Membrane Systems<br />

system covered<br />

4 Scope of coverage Material only; Flex warrants that the Flex membrane material will Material only; GAF warrants that the GAFGLAS roof membrane Material and workmanship; GAF guarantees <strong>to</strong> make repairs <strong>to</strong><br />

be free from defects. and GAF base flashing materials will withstand ordinary wear and GAF EverGuard roofing membrane, coated metal roof edges<br />

tear of the elements and will be free of manufacturing defects that and base flashing, membrane base flashing, expansion joint<br />

affect their ability <strong>to</strong> maintain the roof in a watertight condition. covers, and pre-flashed accessories as are necessary <strong>to</strong> correct<br />

Warranty applies only <strong>to</strong> GAFGLAS roofing membrane and GAF leaks resulting solely from natural deterioration of the<br />

base flashings installed in accordance with current specifications. EverGuard roofing materials and from workmanship in applying<br />

the EverGuard roofing materials<br />

5 Length of coverage 5, 10, or 15 years 10 years 10 years: All materials and systems<br />

15 years: Minimum .045" material, all systems<br />

20 years: Minimum .080" material, new/tear-off systems<br />

6 Nature of remedy Flex's sole obligation shall be <strong>to</strong> repair or replace the defective GAF's sole responsibility is the repair or replacement, at GAF's GAF will make repairs <strong>to</strong> GAF EverGuard roofing membrane,<br />

membrane material option, of that portion of GAF materials that contains coated metal roof edges and base flashing, membrane base<br />

manufacturing defects or deterioration caused by ordinary wear flashing, expansion joint covers, and pre-flashed accessories as<br />

and tear by the elements that have resulted in a roof leak. Repair shall be necessary <strong>to</strong> correct covered leaks at no cost <strong>to</strong> owner.<br />

or replacement of the roof deck or of other materials not sold by Warranty excludes repair or replacement of insulation or other<br />

GAF is not included.<br />

materials not sold by GAF.<br />

7 Monetary limitations Flex's liability shall not exceed the original value of the membrane GAF's maximum liability during first year after completion is the None stated<br />

material.<br />

original cost of GAF materials. After the first year, GAF's<br />

maximum liability is the original cost of the GAF materials reduced<br />

by 10 percent of the maximum liability during each year after the<br />

first year, less any costs previously incurred by GAF for repair or<br />

replacement. In no event shall GAF be liable for a sum greater<br />

than the maximum GAF liability stated herein or more than five<br />

times the proportional cost paid <strong>to</strong> GAF for the GAF materials<br />

installed on the affected portion of the roof, whichever is less<br />

8 Notification requirements Written notification <strong>to</strong> Flex Membrane International, Bethlehem Written notification within 30 days <strong>to</strong> GAF Contrac<strong>to</strong>r Services Written notification within 30 days of discovery of leak <strong>to</strong> GAF<br />

Drive, Morgan<strong>to</strong>wn, PA 19543, by registered mail within 30 days department, 1361 Alps road, Bldg. 7-1, Wayne, NJ 07470 of leaks Contrac<strong>to</strong>r Services Department, 1361 Alps Road, Building 7,<br />

of discovery of any defect in Flex material. resulting from manufacturing defect or ordinary war and tear by the Wayne, NJ 07470. Notice <strong>to</strong> roofing contrac<strong>to</strong>r is not notice <strong>to</strong><br />

elements.<br />

GAF.<br />

9 Exclusive or additional Warranty supersedes and is in lieu of any and all other expressed Warranty is expressly in lieu of any other guarantee and/or Guarantee is expressly in lieu of any other guarantees and/or<br />

remedy warranties that are in conflict with the terms and conditions stated warranties and any other obligations or liability on the part of GAF, warranties and any other obligations or liability on the part of<br />

in warranty whether any claim is based upon strict liability, negligence, breach GAF, whether any claim is based upon strict liability, negligence,<br />

of warranty, or any other theory or cause of action; excludes UCC breach of warranty, or any other theory or cause of action;<br />

warranties<br />

excludes UCC warranties. No representative, employee, or<br />

agent of GAF, or any other person, has any authority <strong>to</strong> assume<br />

for GAF any additional or other liability or responsibility<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Flex's judgment Neutral (no provision) Neutral (no provision)<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 16 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 (including aliphatic or aromatic 1, 2, 3, 4, 5, 6, 7 (not applicable <strong>to</strong> GAF insulation or GAF roof<br />

coverage (see Item 12 in solvents, chlorinated hydrocarbons, turpentine, oils, organic or inorganic base), 8, 9, 10, 11, 12, 13, 15, 17, 22<br />

Introduction)<br />

polar materials), 15, 17, 18, 19, 20, 22; also excludes any damage occurring<br />

more than 30 days after discovery of a leak, unless GAF is notified within 30<br />

days of discovery.<br />

762


13 Wind coverage/exclusions Warranty excludes hurricanes and <strong>to</strong>rnadoes. Flex indicates that Warranty excludes winds<strong>to</strong>rms, hurricanes, and <strong>to</strong>rnadoes. GAF GAF indicates warranty covers roof damage resulting from wind<br />

warranty covers wind speeds up <strong>to</strong> 60 mph indicates that there is no coverage for damage caused by wind speeds up <strong>to</strong> 60 mph. Warranty excludes roof damage resulting<br />

from winds<strong>to</strong>rms above 60 mph, hurricanes and <strong>to</strong>rnadoes.<br />

14 Specific conditions <strong>to</strong> make B, C, F, G, H C, H, I. Also, warranty provides that cancellation of this warranty will result C, H, I, S. Also, guarantee states that cancellation of this guarantee will<br />

the warranty ineffective or if the roof is damaged by any cause listed above as a specific exclusion that result if roof is damaged by any cause listed as an exclusion (See Item 12<br />

null and void (see Item 14 in will affect the integrity or water tightness of the roof. above) if the damage affects the integrity or water tightness of the roof<br />

Introduction)<br />

and owner does not promptly make repairs following notification by GAF<br />

15 Cost <strong>to</strong> obtain 5 years: None; 10 years: $1.00/square; 15 years: $2.00/square None 10 years: $6.00/sq 15 years: $9.00 sq. 20 years: $12.00/sq.<br />

16 Minimum charge 5 years: None; 10 years: $50; 15 years: $100 None 10 years: $500 15 years: $750 20 years; $1,000<br />

17 Ineligible structure or None Domed structures, heated tanks, s<strong>to</strong>rage silos, drying kilns, car wash Private residences, walking decks, buildings with high internal humidity,<br />

building use buildings, swimming pools, and other structures with abnormally high- freezer buildings or buildings used for cold s<strong>to</strong>rage unless approved in<br />

humidity conditions, cold-s<strong>to</strong>rage and cooler buildings when the freezer or writing in advance by GAF.<br />

cooler insulation is used as the base <strong>to</strong> receive the roof<br />

18 Pre-construction notice and The contrac<strong>to</strong>r submits request for guarantee <strong>to</strong> Flex for approval None Pre-installation form is submitted by contrac<strong>to</strong>r, reviewed by Contrac<strong>to</strong>r<br />

approval requirements with roof diagram Services department, project acceptance is faxed and/or mailed back <strong>to</strong><br />

contrac<strong>to</strong>r.<br />

19 Approved, authorized, or licensed Yes No Yes<br />

requirements<br />

20 Job inspection policy Flex technical representative makes on-site inspection prior <strong>to</strong>, during No on-site inspections GAF technical field representative makes on-site inspections prior <strong>to</strong> and<br />

application (a minimum of one inspection), and after completion of<br />

during (as required by project size and project specifications) and after<br />

installation prior <strong>to</strong> issuance of warranty; no charge<br />

application, as well as two years after issuance of warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Although this is a material-only warranty, contrac<strong>to</strong>r is obligated <strong>to</strong> make None; material-only warranty Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> all leaks and<br />

obligation repairs <strong>to</strong> workmanship deficiencies for two years workmanship deficiencies for two years.<br />

22 Backed by named insurance No No; GAF indicates that it does not carry insurance covering its No; GAF indicates it does not carry insurance covering its<br />

or surety warranty obligations. guarantee obligations.<br />

23 Issuing entity manufactures Flex manufactures and sells the product. GAF manufactures and sells the product GAF sells products only.<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision in warranty. Flex indicates that it may issue No renewal provision No renewal provision<br />

extension<br />

extension on individual project basis<br />

25 Assignability Warranty may not be transferred without Flex's written consent. Not transferable or assignable in any manner Assignable <strong>to</strong> another owner only if (1) request is made in writing 30 days<br />

Flex indicates that it permits transfer with written consent from<br />

after ownership transfer; (2) membrane is inspected and any required<br />

Flex and payment of transfer fee.<br />

repairs are completed at owner’s expense; (3) proposed assignment is<br />

approved in writing by an authorized GAF technical services manager;<br />

and (4) an assignment fee of $500 is paid <strong>to</strong> GAF. Otherwise guarantee<br />

is not assignable, directly or indirectly.<br />

26 Special features/condition No representative of Flex has authority <strong>to</strong> make any Owner must sign and mail in GAF warranty registration form within Owner shall, at its expense, (a) perform regular inspections and<br />

representations or promises except as stated in warranty. 30 days of roof completion in order for warranty <strong>to</strong> be effective. No maintenance; (b) keep records of all inspections and maintenance<br />

representative, employee, or agent of GAF, or any other person performed; and © perform repairs <strong>to</strong> the roof or other building<br />

has any authority <strong>to</strong> assume for GAF any additional or other components identified during inspections by GAF as being necessary <strong>to</strong><br />

liability or responsibility. GAF shall not be responsible for or liable preserve the integrity of the GAF roofing materials. Failure of owner <strong>to</strong><br />

for any change or amendment <strong>to</strong> the GAF roof specifications in perform work promptly following written notification by GAF may result in<br />

regard <strong>to</strong> the construction of the roof, unless the change or cancellation of guarantee if the owner’s failure results in damage <strong>to</strong> the<br />

amendment <strong>to</strong> the specifications are approved in writing by an GAF roofing materials.<br />

authorized GAF technical service manager. Owner shall, at its expense, remove (and, if desired, subsequently<br />

replace) any materials and equipment that impede inspection and repair<br />

of the GAF roofing materials, such as HVAC units and satellite dishes<br />

mounted so that there is no functional access <strong>to</strong> the roof system, and<br />

precast concrete or rubber pavers, wood decking or steel grating that are<br />

installed over the GAF roofing materials.<br />

GAF shall not be responsible for or liable for any change or<br />

amendment <strong>to</strong> the GAF roof specifications in regard <strong>to</strong> the roof<br />

construction, unless the change or amendment is approved in writing by<br />

an authorized GAF Contrac<strong>to</strong>r Services manager.<br />

In an emergency, the Owner may authorize or perform temporary<br />

repairs <strong>to</strong> minimize damage <strong>to</strong> the building or its contents. Such work will<br />

not result in the cancellation of guarantee provided that the temporary<br />

repairs are reasonable and cus<strong>to</strong>mary, and do not result in permanent<br />

damage <strong>to</strong> the GAF membrane or base flashing. Owner is responsible for<br />

all expenses associated with temporary repairs.<br />

27 Executed by owner No No<br />

763


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity GAF Materials Corporation (GAF) GAF Materials Corporation (GAF) GAF Materials Corporation (GAF)<br />

2 Title, original publication "Liberty Guarantee"; November 1996; Form 10446 11/96 "Commercial <strong>Roof</strong> Guarantee"; November 1996, Form 10442 11/96 “Ruberoid LMG-Labor and Material Guarantee (A limited warranty);” April,<br />

date, and identifying symbol, 2000; COMTS 560 4/00<br />

if any<br />

3 Product, specification, or system Built-Up <strong>Roof</strong>ing and Modified Bitumen Products: Ruberoid Torch FR, All Ruberoid and GAFGLAS Specifications All Ruberoid Specifications<br />

covered<br />

Ruberoid Torch Plus, Ruberoid Torch, Ruberoid Mop, Ruberoid Mop FR,<br />

Ruberoid Mop 170 FR, Ruberoid Mop Plus, Ruberoid 30 FR, Ruberoid 30,<br />

Ruberoid 20, Ruberoid Mop Smooth, Ruberoid Torch 1, Ruberoid 601 Plus,<br />

Ruberoid Modified Base Sheet, GAFGLAS Ply 6, GAFGLAS Ply 4,<br />

GAFGLAS Flex Ply 6, Ultima 80 Base<br />

4 Scope of coverage Material and workmanship; GAF guarantees <strong>to</strong> make repairs <strong>to</strong> GAF roofing Material and workmanship; GAF guarantees <strong>to</strong> make repairs <strong>to</strong> GAF roofing Material only; GAF warrants that the Ruberoid roof membrane and<br />

membrane, GAF base flashing, GAF insulation, GAF expansion joint covers, membrane, GAF base flashing, GAF insulation, GAF expansion joint covers Ruberoid base flashing materials will withstand ordinary wear and tear by<br />

and GAF pre-flashed accessories as are necessary solely <strong>to</strong> correct leaks and GAF pre-flashed accessories as are necessary solely <strong>to</strong> correct leaks the elements and will be free from manufacturing defects which affect<br />

resulting from natural deterioration of GAF materials; blisters; bare spots; resulting from natural deterioration of GAF materials; blisters; bare spots; their ability <strong>to</strong> maintain the roof in watertight condition. Warranty applies<br />

fishmouths; ridges; splits not caused by structural failure or movement of or fishmouths; ridges; splits not caused by structural failure or movement of or only <strong>to</strong> Ruberoid roof membrane and base flashings installed in<br />

cracks in substrate roof base or non-GAF insulation over which GAF cracks in substrate roof base or non-GAF insulation over which GAF accordance with current GAF specifications.<br />

materials are applied; buckles and wrinkles; workmanship in applying the materials are applied; buckles and wrinkles; workmanship in applying the<br />

GAF materials; and slippage of membrane or base flashing.<br />

GAF materials; and slippage of membrane or base flashing.<br />

5 Length of coverage 5, 10 and 12 years: 3- or 4-ply GAFGLAS Ply 4 or Ply 6 Specifications, 5 and 10 years: 3- or 4-ply GAFGLAS Ply 4 or Ply 6 specifications, 10 years: Ruberoid 30, Ruberoid 30 FR, Ruberoid Torch Smooth<br />

Ruberoid, or Plus specifications; 12 years: Ruberoid or Plus specifications; Ruberoid, or Plus specifications; 10 years: Ruberoid or Plus specifications; 12 years: Ruberoid Mop Granule, Ruberoid Mop 170 FR, Ruberoid<br />

15 or 20 years: 4-Ply GAFGLAS Ply 6 Specifications, Ruberoid Plus spe- 12 years: Ruberoid or Plus specifications; 15 years: 4-ply GAFGLAS Ply 6 Torch Granule & Ruberoid Torch Smooth Coated<br />

cifications. Approved coating or asphalt and gravel must be applied as <strong>to</strong>p specifications, Ruberoid Plus specifications; 20 years: 4-ply GAFGLAS Ply 15 years: Ruberoid Mop Plus, Ruberoid Mop Plus FR, Ruberoid Torch<br />

covering for smooth surface Ruberoid membrane <strong>to</strong> obtain 12-year Rube- 6 specifications, Ruberoid Plus specifications. Approved coating or asphalt FR; Ruberoid Torch Plus 15<br />

roid Liberty Guarantee.<br />

and gravel must be applied as <strong>to</strong>p covering for smooth surface Ruberoid<br />

membrane <strong>to</strong> obtain 10, 15, or 20-year guarantee.<br />

6 Nature of remedy GAF will make repairs <strong>to</strong> GAF membrane, base flashing, insulation, GAF will make repairs <strong>to</strong> GAF membrane, base flashing, insulation, GAF’s sole responsibility is <strong>to</strong> repair that portion of the Ruberoid<br />

expansion joint covers, and pre-flashed accessories as shall be necessary expansion joint covers, and pre-flashed accessories as shall be necessary materials that contains manufacturing defects or deterioration caused by<br />

solely in order <strong>to</strong> correct covered leaks at no cost <strong>to</strong> owner. Warranty solely in order <strong>to</strong> correct covered leaks at no cost <strong>to</strong> the owner. Warranty ordinary wear and tear by the elements that have resulted in a roof leak.<br />

excludes repair or replacement of materials not sold by GAF. excludes repair or replacement of materials not sold by GAF. Repair or replacement of the roof deck or <strong>to</strong> the roof components used in<br />

conjunction with the Ruberoid Materials is not included.<br />

7 Monetary limitations None stated. GAF's maximum liability shall not exceed in the aggregate over the life of None stated<br />

the guarantee more than $100 per square.<br />

8 Notification requirements Written notification within 30 days of discovery of leak <strong>to</strong> GAF Contrac<strong>to</strong>r Written notice within 30 days of discovery of leak <strong>to</strong> GAF Contrac<strong>to</strong>r Written notice within 30 days after discovery of the leak <strong>to</strong> GAF<br />

Services department, 1361 Alps Road, Building 7-B, Wayne, NJ 07470 Services department, 1361 Alps Road, Building 7-B, Wayne, NJ 07470 Contrac<strong>to</strong>r Services Department, 1361 Alps Road, Wayne, New Jersey<br />

07470.<br />

9 Exclusive or additional remedy The guarantee is expressly in lieu of any other guarantees and/or warranties The guarantee is expressly in lieu of any other guarantees and/or warranties Warranty is expressly in lieu of any other guarantees or warranties and of<br />

and any other obligations or liability on the part of GAF, whether any claim and any other obligations or liability on the part of GAF whether any claim is any other obligations or liability on the part of GAF, whether any claim is<br />

is based upon strict liability, negligence, breach of warranty, or any other based upon strict liability, negligence, breach of warranty, or any other based upon strict liability, negligence, breach of warranty, or any other<br />

theory or cause of action; excludes UCC warranties. theory or cause of action; excludes UCC warranties. theory or cause of action; excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (no provision) Neutral (no provision) Neutral (no provision)<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 7 (not applicable <strong>to</strong> GAF insulation or GAF roof base), 8, 9, 1, 2, 3, 4, 5, 6, 7 (not applicable <strong>to</strong> GAF insulation or GAF roof base), 8, 9, 1, 2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13 (including aliphatic or aromatic<br />

coverage (see Item 12 in 10, 11, 12, 13, 15, 17, 22, 24. 10, 11, 12, 13, 15, 17, 22, 24. solvents, chlorinated hydrocarbons, turpentine, oils, organic or inorganic<br />

Introduction) polar materials), 15, 18, 19, 20, 22.<br />

13 Wind coverage/exclusions Warranty excludes winds<strong>to</strong>rms, hurricanes, and <strong>to</strong>rnadoes. GAF indicates Warranty excludes winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. GAF indicates Warranty excludes winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. GAF<br />

that there is no coverage for damage caused by wind that there is no coverage for damage caused by wind indicates that there is no coverage for damage caused by wind.<br />

14 Specific conditions <strong>to</strong> make the C, H, I, S. Also, guarantee states that cancellation of this guarantee will C, H, I, S. Also, the guarantee states that cancellation of this guarantee will F, R. Warranty is not effective unless the warranty is properly registered<br />

warranty ineffective or null and result if roof is damaged by any cause listed as an exclusion (See Item 12 result if the roof is damaged by any cause listed as an exclusion (See Item within 120 days of the completion of the roof. Also, warranty states that<br />

void (see Item 14 in Introduction) above) if the damage affects the integrity or water tightness of the roof and 12 above) if the damage affects the integrity or water tightness of the roof cancellation of the warranty will result if the roof is damaged by any<br />

owner does not promptly make repairs following notification by GAF. and owner does not promptly make repairs following notification by GAF. cause listed as an exclusion (See Item 12 above) if the damage affects<br />

the integrity or watertightness of the roof.<br />

15 Cost <strong>to</strong> obtain 5 yrs: $ 5.00/sq; 10 yrs: $ 9.00/sq.; 12 yrs: $10.00/sq; 5 yrs: $ 4.00/sq; 10 yrs: $ 6.00/sq; 12 yrs: $7.00/sq; None<br />

15 yrs: $12.00/sq; 20 yrs: $17.00/sq 15 yrs: $9.00/sq; 20 yrs: $12.00/sq<br />

16 Minimum charge 5 yrs: $350; 10 yrs: $750; 12 yrs: $750; 5 yrs: $350; 10 yrs: $500; 12 yrs: $500; None<br />

15 yrs: $800; 20 yrs: $1,000 15 yrs: $500; 20 yrs: $500<br />

764


17 Ineligible structure or<br />

building use<br />

18 Pre-construction notice and<br />

approval requirements<br />

19 Approved, authorized, or<br />

licensed requirements<br />

High-humidity buildings (i.e., car washes, swimming pools), domed Domed structures, heated tanks, s<strong>to</strong>rage silos, drying kilns, car wash Cannot have high internal humidity, or be used as freezer buildings for<br />

structures, heated tanks, s<strong>to</strong>rage silos, drying kilns, freezer or cooler buildings, swimming pools and other structures with abnormally high cold s<strong>to</strong>rage. GAF indicates that the Ruberoid application and<br />

buildings when the freezer or cooler insulation is also the roof insulation. humidity conditions, cold-s<strong>to</strong>rage and cooler buildings when the freezer or specification manual lists other ineligible structures or building uses.<br />

cooler insulation is used as the base <strong>to</strong> receive the roof.<br />

The contrac<strong>to</strong>r must submit a notice of award of contract at least ten days Contrac<strong>to</strong>r must submit a notice of award of contract prior <strong>to</strong> None<br />

prior <strong>to</strong> commencement, providing job details.<br />

commencement, providing job details.<br />

Yes Yes Yes<br />

20 Job inspection policy GAF terri<strong>to</strong>ry manager makes on-site inspections prior <strong>to</strong> and during GAF terri<strong>to</strong>ry manager makes on-site inspections prior <strong>to</strong> and during No on-site inspections<br />

application. GAF field technical representative makes on-site inspections application. GAF field technical representative makes on-site inspections<br />

after completion prior <strong>to</strong> issuance of warranty, as well as two years after after completion, prior <strong>to</strong> issuance of guarantee, as well as two years after<br />

issuance of warranty; no charge.<br />

issuance of guarantee; no charge<br />

21 Contrac<strong>to</strong>r’s post-installation<br />

obligation<br />

22 Backed by named insurance or<br />

surety<br />

23 Issuing entity manufactures<br />

and/or sells products<br />

24 Conditions for renewal or<br />

extension<br />

The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> all leaks and workmanship Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> all leaks and workmanship None<br />

deficiencies for two years.<br />

deficiencies for two years<br />

No; GAF indicates that it does not carry insurance covering its guarantee No; GAF indicates it does not carry insurance covering its guarantee No; GAF indicates that it does not carry insurance covering its warranty<br />

obligations. obligations. obligations.<br />

GAF manufactures and sells product. GAF manufactures and sells product. GAF manufactures and sells product.<br />

Ruberoid Liberty guarantees may be renewed for five years at a cost of<br />

th<br />

The owner requests during the last 6 months of the 5 year that GAF make No renewal provision<br />

$5.00 per square. Inspection is required and repairs are at owner’s roof inspection free of charge. GAF will advise the owner of any repairs<br />

expense. Application of Matrix modified bitumen coating is required. necessary <strong>to</strong> qualify for additional 5 yrs. The owner must make repairs at<br />

Contact GAF for program details<br />

his sole expense & notify GAF no later than 45 days after the expiration of<br />

the original 5-yr. guarantee. GAF will then reinspect and, if acceptable,<br />

guarantee will be extended for 5 yrs. GAF reserves the right <strong>to</strong> refuse <strong>to</strong><br />

renew the guarantee if GAF determines repairs are needed due <strong>to</strong> specific<br />

exclusions from guarantee coverage.<br />

25 Assignability Assignable <strong>to</strong> another owner only if (1) request is made in writing 30 days Assignable <strong>to</strong> another owner only if (1) request is made in writing within 30 Not transferable or assignable in any manner.<br />

after ownership transfer; (2) membrane is inspected and any required days after ownership transfer, (2) membrane is inspected and any required<br />

repairs are completed at owner's expense; (3) proposed assignment is repairs are completed at owner's expense, (3) proposed assignment is<br />

approved in writing by an authorized GAF Contrac<strong>to</strong>r Services manager; approved in writing by an authorized GAF Contrac<strong>to</strong>r Services manager,<br />

and (4) an assignment fee of $500 is paid <strong>to</strong> GAF. Otherwise, guarantee is and (4) an assignment fee of $500 is paid. Otherwise, guarantee is not<br />

not assignable, directly or indirectly.<br />

assignable, directly or indirectly.<br />

26 Special features/condition Owner shall, at its expense, (a) perform regular inspections and Owner shall, at its expense, (a) perform regular inspections and Owner must sign and mail in GAF warranty registration form within 120<br />

maintenance; (b) keep records of all inspections and maintenance maintenance; (b) keep records of all inspections and maintenance days of roof completion in order for warranty <strong>to</strong> be effective. No<br />

performed; and © perform repairs <strong>to</strong> the roof or other building components performed; and © perform repairs <strong>to</strong> the roof or other building components representative, employee, or agent of GAF, or any other person, has any<br />

identified during inspections by GAF as being necessary <strong>to</strong> preserve the identified during inspections by GAF as being necessary <strong>to</strong> preserve the authority <strong>to</strong> assume for GAF any additional or other liability or<br />

integrity of the GAF roofing materials. Failure of owner <strong>to</strong> perform work integrity of the GAF roofing materials. Failure of owner <strong>to</strong> perform work responsibility. GAF shall not be responsible for any changes <strong>to</strong> the GAF<br />

promptly following written notification by GAF may result in cancellation of promptly following written notification by GAF may result in cancellation of Ruberoid specifications applicable <strong>to</strong> the roof unless the change is<br />

guarantee if the owner's failure results in damage <strong>to</strong> the GAF roofing guarantee if the owner's failure results in damage <strong>to</strong> the GAF roofing approved in writing by an authorized GAF Contrac<strong>to</strong>r Services Manager.<br />

materials.<br />

materials.<br />

Owner shall, at its expense, remove (and, if desired, subsequently replace) Owner shall, at its expense, remove (and, if desired, subsequently replace)<br />

any materials and equipment that impede inspection and repair of the GAF any materials and equipment that impede inspection and repair of the GAF<br />

roofing materials, such as HVAC units and satellite dishes mounted so that roofing materials, such as HVAC units and satellite dishes mounted so that<br />

there is no functional access <strong>to</strong> the roof system, and precast concrete or there is no functional access <strong>to</strong> the roof system, and precast concrete or<br />

rubber pavers, wood decking or steel grating that are installed over the GAF rubber pavers, wood decking and steel grating that are installed over the<br />

roofing materials.<br />

GAF roofing materials.<br />

No representative, employee, or agent of GAF, or any other person, has any No representative, employee, or agent of GAF, or any other person, has any<br />

authority <strong>to</strong> assume for GAF any additional or other liability or responsibility. authority <strong>to</strong> assume for GAF any additional or other liability or responsibility.<br />

GAF shall not be responsible for or liable for any change or amendment <strong>to</strong> GAF shall not be responsible for or liable for any change or amendment <strong>to</strong><br />

the GAF roof specifications, unless the change or amendment <strong>to</strong> the the GAF roof specifications, unless the change or amendment is approved<br />

specifications is approved in writing by an authorized GAF technical service in writing by an authorized GAF Contrac<strong>to</strong>r Services manager. The roofing<br />

manager.<br />

contrac<strong>to</strong>r is not an agent of GAF; notice <strong>to</strong> the roofing contrac<strong>to</strong>r is not<br />

In an emergency, the Owner may authorize or perform temporary repairs <strong>to</strong> notice <strong>to</strong> GAF.<br />

minimize damage <strong>to</strong> the building or its contents. Such work will not result in In an emergency, the owner may authorize or perform temporary repairs <strong>to</strong><br />

the cancellation of guarantee provided that the temporary repairs are minimize damage <strong>to</strong> the building or its contents. Such work will not result in<br />

reasonable and cus<strong>to</strong>mary, and do not result in permanent damage <strong>to</strong> the the cancellation of guarantee provided the temporary repairs are reasonable<br />

GAF membrane or base flashing. Owner is responsible for all expenses and cus<strong>to</strong>mary and do not result in permanent damage <strong>to</strong> the GAF<br />

associated with temporary repairs.<br />

membrane or base flashing. Owner is responsible for all expenses<br />

associated with temporary repairs.<br />

27 Executed by owner No No Yes (See Special Features/Conditions.)<br />

765


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity GAF Materials Corporation (GAF) GAF Materials Corporation (GAF) GAF Materials Corporation (GAF)<br />

2 Title, original publication “Limited Warranty on Material Ruberoid Ten”; March 1994; Form 10301 "Liberty PDR Guarantee"; November 1996; Form 10457 11/96 "Liberty LWIC Single Source Guarantee"; December 1996; Form 10459<br />

date, and identifying symbol, 3/94 12/96<br />

if any<br />

3 Product, specification, or system All Ruberoid specifications Modified Bitumen Specifications: NN-O-2-MS(PD), I-O-2-MS(PD), NN-O-2- GAFGLAS Built-Up <strong>Roof</strong> Specifications: N-B-5-G, N-B-5-C, N-B-5-M, N-B-4-G,<br />

covered TS(PD), I-O-2-TS(PD), NN-O-3-MS(PD), I-O-3-MS(PD), NN-O-3-TS(PD), I- N-B-4-C, N-B-4-M, N-B-5-G/P6, N-B-5-C/P6, N-B-5-M/P6, N-B-4-G/P6, N-B-4-<br />

O-3-TS(PD)<br />

C/P6, N-B-4-M/P6; Ruberoid Modified Bitumen Specifications: N-1-2-20/30, N-1-<br />

2-20/30FR, N-1-1-TS, N-1-1-TG, N-1-1-TSC, N-1-1-MG, N-1-1-MGFR, N-1-1-<br />

MSG, N-2-1-MGP, N-2-1-MGPFR, N-3-1-MGP, N-3-1-MGPFR, N-1-2-20/MG, N-<br />

1-2-20/MGRF, N-1-2-20/MSG, N-1-2-20/MGP, N-1-2-20/MGPFR, N-2-1-TGP, N-<br />

2-1-TGPFR, N-3-1-TGP, N-3-1-TGPFR, N-1-2-TGP, N-1-2-TGPFR, N-1-2-TG<br />

4 Scope of coverage Material only; GAF warrants that the Ruberoid roofing membrane and Material and workmanship; GAF guarantees GAF roofing membrane, GAF base Material and workmanship; GAF guarantees <strong>to</strong> make repairs <strong>to</strong> GAF roofing<br />

Ruberoid base flashing materials will withstand ordinary wear and tear by flashing, GAF underlying insulation, GAF expansion joint covers and GAF pre- membrane, GAF base flashing, GAF expansion joint covers, GAF pre-flashed<br />

the elements and will be free of manufacturing defects that affect their ability flashed accessories installed with an above-grade plaza deck assembly will accessories and GAF lightweight concrete insulation as are necessary solely <strong>to</strong><br />

<strong>to</strong> maintain the roof in a watertight condition. Warranty applies only <strong>to</strong> withstand ordinary wear and tear by the elements and will be free of manufacturing correct leaks resulting from natural deterioration of GAF materials; blisters; bare<br />

Ruberoid roofing membrane and Ruberoid base flashings installed in and installation workmanship defects which affect its ability <strong>to</strong> maintain a watertight spots; fishmouths; ridges; buckles and wrinkles; splits not caused by structural<br />

accordance with current Ruberoid specifications condition. Warranty covers repairs <strong>to</strong> the GAF materials as shall be necessary failure or movement or cracks in substrate or roof base (other than the LWIC<br />

solely <strong>to</strong> correct leaks resulting from natural deterioration of GAF materials; blisters; insulation) over which GAF materials are applied; workmanship in applying the<br />

fishmouths; ridges; splits not caused by structural failure or movement of or cracks GAF materials; and slippage of membrane or base flashing.<br />

in substrate roof base or non-GAF insulation over which GAF materials are applied; GAF also warrants that, as <strong>to</strong> the LWIC insulation, the actual resistance <strong>to</strong><br />

buckles and wrinkles; workmanship in applying the GAF materials; slippage of heat flow through the LWIC insulation will be at least 80% of the design thermal<br />

membrane or base flashing; and normal pedestrian plaza deck usage.<br />

resistance and that the LWIC will not cause the roofing membrane <strong>to</strong> leak as a<br />

Guarantee covers repairs <strong>to</strong> GAF roofing materials and does not include repair or result of the vapor pressure effects (blisters) of moisture retained within the LWIC<br />

replacement of roof deck, insulation, protection boards, drainage boards and traffic or cause structural damage <strong>to</strong> the building as a result of thermal or chemical<br />

surfacing used in conjunction with the plaza deck assembly not sold by GAF. reactions.<br />

5 Length of coverage 10 years; 12 years with GAF weather-coated emulsion or fibered aluminum 10 years: NN-O-2-MS(PD), I-O-2-MS(PD), NN-O-2-TS(PD), I-O-2-TS(PD); 5, 10 and 12 years: 3- or 4-ply GAFGLAS Ply 4 or Ply 6 Specifications,<br />

coating, or granule surface. 15 or 20 years: NN-O-3-MS(PD), I-O-3-MS(PD), NN-O-3-TS(PD), I-O-3- Ruberoid or Plus Specifications; 12 years: Ruberoid or Plus<br />

TS(PD)<br />

Specifications; 15 or 20 years: 4-Ply GAFGLAS Ply 6 Specifications,<br />

Ruberoid Plus Specifications. Approved coating or asphalt and gravel<br />

must be applied as <strong>to</strong>p covering for smooth surface Ruberoid membrane<br />

<strong>to</strong> obtain 12 year guarantee.<br />

6 Nature of remedy GAF's sole responsibility is the repair or replacement, at GAF's option, of GAF will make repairs <strong>to</strong> GAF membrane, base flashing, insulation, GAF will make repairs <strong>to</strong> GAF membrane, base flashing, expansion joint<br />

that portion of Ruberoid materials that contains manufacturing defects or expansion joint covers and pre-flashed accessories as shall be necessary covers, pre-flashed accessories and lightweight concrete insulation as<br />

deterioration caused by ordinary wear and tear by the elements that have solely in order <strong>to</strong> correct covered leaks. Warranty excludes repair or shall be necessary solely in order <strong>to</strong> correct covered leaks at no cost <strong>to</strong><br />

resulted in a roof leak. replacement of materials not sold by GAF. Removal and replacement of owner. Warranty excludes repair or replacement of roof deck or other<br />

plaza deck assembly materials <strong>to</strong> expose the GAF materials shall be made materials not sold by GAF.<br />

at the sole cost of the Owner even if GAF determines the leak is covered by Should the LWIC insulation fail <strong>to</strong> perform, GAF shall, at its own<br />

the GAF guarantee.<br />

expense, (1) make or cause <strong>to</strong> be made repairs or modifications <strong>to</strong> the<br />

LWIC insulation as GAF deems appropriate so that the LWIC insulation<br />

will perform as warranted, and (2) repair or replace the roof membrane <strong>to</strong><br />

the extent that it is damaged as a result of the failure of the LWIC<br />

insulation <strong>to</strong> perform as warranted as a result of repairs or modifications<br />

<strong>to</strong> the LWIC insulation.<br />

7 Monetary limitations GAF's maximum liability during the first year after completion is the original None stated. None stated.<br />

cost of Ruberoid materials. After the first year, GAF's maximum liability is<br />

the original cost of the Ruberoid materials reduced by ten percent of the<br />

maximum liability during each year after the first year, less any costs<br />

previously incurred by GAF for repair or replacement. In no event shall GAF<br />

be liable for a sum greater than maximum liability of warranty or more than<br />

five times the proportional cost paid <strong>to</strong> GAF for the Ruberoid materials<br />

installed on the affected portion of the roof, whichever is less.<br />

8 Notification requirements Written notification within 30 days <strong>to</strong> nearest GAF Contrac<strong>to</strong>r services, 1361 Written notification within 30 days of discovery of leak <strong>to</strong> GAF Contrac<strong>to</strong>r Written notification within 30 days of discovery of leak or a failure of the<br />

Alps Road, Wayne, NJ Bldg 7of leak resulting from manufacturing defect or Services Department, 1361 Alps Road, Building 7-1, Wayne, NJ 07470. LWIC insulation <strong>to</strong> GAF Contrac<strong>to</strong>r Services Department, 1361 Alps<br />

ordinary wear and tear by the elements. Road, Building 7-1, Wayne, NJ 07470.<br />

9 Exclusive or additional remedy Warranty is expressly in lieu of any other guarantee and/or warranties and Guarantee is expressly in lieu of any other guarantees and/or warranties Guarantee is expressly in lieu of any other guarantees and/or warranties<br />

any other obligations or liability on the part of GAF, whether any claim is and any other obligations or liability on the part of GAF, whether any claim and any other obligations or liability on the part of GAF, whether any<br />

based upon strict liability, negligence, breach of warranty, or any other is based upon strict liability, negligence, breach of warranty, or any other claim is based upon strict liability, negligence, breach of warranty or any<br />

theory or cause of action; excludes UCC warranties. theory or cause of action; excludes UCC warranties. other theory or cause of action; excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (no provision) Neutral (no provision) Neutral (no provision)<br />

applicability<br />

766


12 Specific exclusions from 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 (including aliphatic or aromatic 1, 2, 3, 4, 5, 6, 7, 8, 10, 11, 13, 15, 17, 22, 24. Warranty also excludes new 1, 2, 3, 4, 5, 6, 7 (not applicable <strong>to</strong> GAF insulation or GAF roof base), 8,<br />

coverage (see Item 12 in solvents, chlorinated hydrocarbons, turpentine, oils, organic or inorganic penetrations, modifications or additions, damage resulting from removal of 9, 10, 11, 12, 13, 15, 17, 22, 24. Also excludes any damage occurring<br />

Introduction) polar materials), 15, 17, 18, 19, 20, 22. Also excludes any damage plaza decking material applied over the GAF roofing materials, and damage more than 30 days after discovery of a leak unless GAF is notified within<br />

occurring more than 30 days after discovery of a leak, unless GAF is caused by vehicular traffic on the plaza deck. 30 days of discovery, and damage due <strong>to</strong> underlying materials or<br />

notified within 30 days of discovery.<br />

structures having failed or ceased <strong>to</strong> conform <strong>to</strong> GAF's or other<br />

applicable specifications as <strong>to</strong> roof slopes or other requirements.<br />

13 Wind coverage/exclusions Warranty excludes winds<strong>to</strong>rms, hurricanes, and <strong>to</strong>rnadoes. GAF indicates Warranty excludes winds<strong>to</strong>rms, hurricanes, and <strong>to</strong>rnadoes. GAF indicates Warranty excludes winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. GAF<br />

that there is no coverage for damage caused that there is no coverage for damage caused by wind indicates that there is no coverage for damage caused by wind.<br />

by wind<br />

14 Specific conditions <strong>to</strong> make the C, H, I. Also, warranty provides that cancellation of this warranty will result C, H, I, S. Also, guarantee states that cancellation of this guarantee will result if roof C, H, I, S. Also, the guarantee states that cancellation of this guarantee will<br />

warranty ineffective or null and if the roof is damaged by any cause listed above as a specific exclusion that is damaged by any cause listed as an exclusion (See Item 12 above) if the damage result if roof is damaged by any cause listed as an exclusion if the damage affects<br />

void (see Item 14 in Introduction) will affect the integrity or water tightness of the roof. affects the integrity or water tightness of the roof and owner does not promptly make the integrity or water tightness of the roof and the owner does not promptly make<br />

repairs following notification by GAF.<br />

repairs <strong>to</strong> rectify the damage and preserve the integrity of the roof following<br />

notification by GAF.<br />

15 Cost <strong>to</strong> obtain None C, H, I, S. Also, guarantee states that cancellation of this guarantee will result if roof 5 years: $6.00/square; 10 years: $10.00/square; 12 years:<br />

is damaged by any cause listed as an exclusion (See Item 12 above) if the damage $12.00/square; 15 years: $14.00/square; 20 years: $19.00/square<br />

affects the integrity or water tightness of the roof and owner does not promptly make<br />

repairs following notification by GAF.<br />

16 Minimum charge None 10 years: $800; 15 years: $1,000; 20 years: $1,200 5 yrs: $450; 10 yrs: $850; 12 yrs: $900; 15 yrs: $1,000; 20 yrs: $1,200<br />

17 Ineligible structure or building Domed structures, heated tanks, s<strong>to</strong>rage silos, drying kilns, car wash High-humidity buildings (i.e., car washes, swimming pools), domed High-humidity buildings (i.e., car washes, swimming pools), domed<br />

use buildings, swimming pools and other structures with abnormally high- structures, heated tanks, s<strong>to</strong>rage silos, drying kilns, freezer or cooler structures, heated tanks, s<strong>to</strong>rage silos, drying kilns, freezer or cooler<br />

humidity conditions, cold-s<strong>to</strong>rage and cooler buildings when the freezer or buildings when freezer or cooler insulation is also the roof insulation. buildings when the freezer or cooler insulation is also the roof insulation.<br />

cooler insulation is used as the base <strong>to</strong> receive the roof<br />

18 Pre-construction notice and None Contrac<strong>to</strong>r must submit a notice of award of contract at least ten days prior The contrac<strong>to</strong>r must submit a notice of award of contract at least ten days<br />

approval requirements <strong>to</strong> commencement, providing job details. prior <strong>to</strong> commencement, providing job details.<br />

19 Approved, authorized, or licensed None Yes Yes<br />

requirements<br />

20 Job inspection policy No on-site inspections GAF terri<strong>to</strong>ry manager makes on-site inspections prior <strong>to</strong> and during application. GAF terri<strong>to</strong>ry manager makes on-site inspections prior <strong>to</strong> and during application.<br />

GAF field technical representative makes on-site inspections after completion prior GAF field technical representative makes on-site inspections after completion<br />

<strong>to</strong> issuance of guarantee, as well as two years after issuance of guarantee; no prior <strong>to</strong> issuance of warranty, as well as two years after issuance of warranty; no<br />

charge. Flood testing of all plaza deck roofing installations is required.<br />

charge.<br />

21 Contrac<strong>to</strong>r’s post-installation None Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> all leaks and workmanship Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> all leaks and workmanship<br />

obligation deficiencies for two years. deficiencies for two years.<br />

22 Backed by named insurance or No; GAF indicates that it does not carry insurance covering its warranty No; GAF indicates it does not carry insurance covering its guarantee No; GAF indicates it does not carry insurance covering its guarantee<br />

surety obligations. obligations. obligations.<br />

23 Issuing entity manufactures GAF manufactures and sells the product. GAF manufactures and sells the product. GAF manufactures and sells the product.<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability Not transferable or assignable in any manner Assignable <strong>to</strong> another owner only if (1) request is made in writing 30 days after ownership Assignable <strong>to</strong> another owner only if (1) request is made in writing 30 days after ownership<br />

transfer; (2) the visible GAF roofing materials and plaza deck are inspected and any required transfer; (2) membrane is inspected and any required repairs are completed at owner's<br />

repairs are completed at owner's expense; (3) proposed assignment is approved in writing by expense; (3) proposed assignment is approved in writing by an authorized GAF technical<br />

an authorized GAF technical services manager; and (4) an assignment fee of $500 is paid <strong>to</strong> services manager; and (4) an assignment fee of $500 is paid <strong>to</strong> GAF. Otherwise,<br />

GAF. Otherwise, guarantee is not assignable, directly or indirectly.<br />

guarantee is not assignable, directly or indirectly.<br />

26 Special features/condition The owner must sign and mail in GAF warranty registration form within 30 Upon request by GAF, the owner shall remove (and subsequently replace) Owner shall, at its expense, (a) perform regular inspections and maintenance; (b) keep<br />

days of roof completion in order for warranty <strong>to</strong> be effective. No all plaza deck assembly materials <strong>to</strong> expose the GAFMC <strong>Roof</strong>ing Materials records of all inspections and maintenance performed; and © perform repairs <strong>to</strong> the roof<br />

representative, employee, or agent of GAF, or any other person has any <strong>to</strong> allow for inspection and repair of the GAFMC <strong>Roof</strong>ing Materials. or other building components identified during inspections by GAF as being necessary <strong>to</strong><br />

authority <strong>to</strong> assume for GAF any additional or other liability or responsibility. Removal and replacement of the plaza deck assembly materials shall be preserve the integrity of the GAF roofing materials. Failure of owner <strong>to</strong> perform work<br />

GAF shall not be responsible for or liable for any change or amendment <strong>to</strong> made at the sole cost of the owner even if GAF determines that the leak is promptly following written notification by GAF may result in cancellation of guarantee if the<br />

the GAF roof specifications in regard <strong>to</strong> the construction of the roof , unless covered by this guarantee. No representative, employee, or agent of GAF, owner's failure results in damage <strong>to</strong> the GAF roofing materials.<br />

the change or amendment <strong>to</strong> the specifications are approved in writing by or any other person, has any authority <strong>to</strong> assume for GAF any additional or Owner shall, at its expense, remove (and, if desired, subsequently replace) any materials<br />

an authorized GAF technical service manager other liability or responsibility. GAF shall not be responsible for or liable for and equipment that impede inspection and repair of the GAF roofing materials, such as<br />

any change or amendment <strong>to</strong> the GAF roof specifications, unless the<br />

HVAC units and satellite dishes mounted so that there is no functional access <strong>to</strong> the roof<br />

change or amendment <strong>to</strong> the specification is approved in writing by an system, and precast concrete or rubber pavers, wood decking or steel grating that are<br />

authorized GAF technical service manager.<br />

installed over the GAF roofing materials.<br />

No representative, employee, or agent of GAF, or any other person, has any authority <strong>to</strong><br />

assume for GAF any additional or other liability or responsibility. GAF shall not be<br />

responsible for or liable for any change or amendment <strong>to</strong> the GAF roof specifications,<br />

unless the change or amendment <strong>to</strong> the specifications is approved in writing by an<br />

authorized GAF technical service manager.<br />

In an emergency, the Owner may authorize or perform temporary repairs <strong>to</strong> minimize<br />

damage <strong>to</strong> the building or its contents. Such work will not result in the cancellation of<br />

guarantee provided that the temporary repairs are reasonable and cus<strong>to</strong>mary, and do not<br />

result in permanent damage <strong>to</strong> the GAF membrane or base flashing. Owner is<br />

responsible for all expenses associated with temporary repairs.<br />

No claim may be made in respect <strong>to</strong> thermal performance unless based on tests carried<br />

out by a qualified labora<strong>to</strong>ry using tests and procedures satisfac<strong>to</strong>ry <strong>to</strong> GAF. GAF<br />

reserves the right <strong>to</strong> perform thermal testing on the LWIC insulation at its discretion and at<br />

its own cost.<br />

27 Executed by owner Yes (See Special Features/Conditions. No No<br />

767


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity GAF Materials Corporation (GAF) GAF Materials Corporation (GAF) GAF Materials Corporation (GAF)<br />

2 Title, original publication "EverGuard Material Only Guarantee (A Limited Warranty);" "EverGuard Silver Seal Guarantee;" January 1998; Form 10511 “Tri-Ply - Ten Year Limited Warranty on Material;” January 1,<br />

date, and identifying symbol, January 1, 1998; Form 10512 1/98 1/98 2000<br />

if any<br />

3 Product, specification, or All EverGuard Single-Ply Membrane Applications EverGuard Single-Ply Membrane Systems All Tri-Ply modified bitumen specifications<br />

system covered<br />

4 Scope of coverage Material only; GAF warrants that the EverGuard roof membrane Material and workmanship; GAF guarantees <strong>to</strong> make repairs <strong>to</strong> Material only; GAF warrants that the TriPly roof membrane and<br />

and EverGuard coated metal and membrane flashing materials GAF EverGuard roofing membrane, coated metal roof edges and base flashing materials will withstand ordinary wear and tear by<br />

will withstand ordinary wear and tear by the elements and will be base flashing, membrane base flashing, expansion joint covers, the elements and will be free of manufacturing defects which<br />

free of manufacturing defects which affect their ability <strong>to</strong> maintain and pre-flashed accessories as are necessary <strong>to</strong> correct leaks affect their ability <strong>to</strong> maintain the roof in watertight condition.<br />

the roof in watertight condition.<br />

resulting solely from natural deterioration of the EverGuard roofing<br />

materials and from workmanship in applying the EverGuard<br />

roofing materials.<br />

5 Length of coverage 10 years 10 years: All materials and systems 10 years<br />

15 years: Minimum .045" material, all systems<br />

20 years: Minimum .080" material, new/tear-off systems<br />

6 Nature of remedy GAF's sole responsibility is the repair or replacement, at GAF's option, of GAF will make repairs <strong>to</strong> GAF EverGuard roofing membrane, GAF’s sole responsibility is the repair or replacement, at GAF’s<br />

coated metal roof edges and base flashing, membrane base option, of that portion of the Tri-Ply materials that contain<br />

that portion of the EverGuard materials that contains manufacturing defects<br />

or deterioration caused by ordinary wear and tear by the elements that have<br />

resulted in a roof leak. Repair or replacement of the roof deck or other roof<br />

components used with the EverGuard materials is not included. If GAF<br />

determines there are manufacturing defects covered by this warranty, GAF<br />

will repair or replace the EverGuard materials within 90 days after<br />

notification of leaks.<br />

flashing, expansion joint covers, and pre-flashed accessories as<br />

shall be necessary <strong>to</strong> correct covered leaks at no cost <strong>to</strong> owner.<br />

Warranty excludes repair or replacement of insulation or other<br />

materials not sold by GAF<br />

7 Monetary limitations None stated GAF’s maximum liability shall not exceed in the aggregate over<br />

the life of guarantee more than the original cost of the GAF<br />

supplied materials and reasonable and cus<strong>to</strong>mary cost of labor<br />

used <strong>to</strong> install such materials<br />

8 Notification requirements Written notice within 30 days of discovery of leak <strong>to</strong> GAF Written notification within 30 days of discovery of leak <strong>to</strong> GAF<br />

EverGuard Contrac<strong>to</strong>r Services Department, 1361 Alps Road, Contrac<strong>to</strong>r Services Department, 1361 Alps Road, Building 7,<br />

Building 7, Wayne, NJ 07470. Notice <strong>to</strong> the roofing contrac<strong>to</strong>r is Wayne, NJ 07470. Notice <strong>to</strong> roofing contrac<strong>to</strong>r is not notice <strong>to</strong><br />

not notice <strong>to</strong> GAF.<br />

GAF<br />

9 Exclusive or additional<br />

remedy<br />

manufacturing defects or deterioration caused by ordinary wear<br />

and tear by the elements that have resulted in a roof leak.<br />

GAF’s maximum liability for cost of repairs or replacement during the first<br />

year after completion is the original cost of the Tri-Ply materials only.<br />

After the first year, GAF’s maximum liability is the original cost of the Tri-<br />

Ply materials reduced by 10% of the maximum liability during each year<br />

after the first year of the warranty, less any costs previously incurred by<br />

GAF for repair or replacement during previous years.<br />

Written notice within 30 days after discovery of the leak <strong>to</strong> GAF<br />

Contrac<strong>to</strong>r Services Department, 1361 Alps Road, Wayne, New Jersey<br />

07470. Notice <strong>to</strong> the roofing contrac<strong>to</strong>r is not notice <strong>to</strong> GAF. Notice must<br />

include a copy of the warranty or proof of purchase of Tri-Ply materials.<br />

Warranty is expressly in lieu of any other guarantees and/or warranties and Guarantee is expressly in lieu of any other guarantees and/or warranties Warranty is expressly in lieu of any other guarantee and/or warranties<br />

any other obligations or liability on the part of GAF whether any claim is and any other obligations or liability on the part of GAF, whether any claim and any other obligations or liability on the part of GAF whether any claim<br />

based upon strict liability, negligence, breach of warranty, or any other is based upon strict liability, negligence, breach of warranty, or any other is based upon strict liability, negligence, breach of warranty, or any other<br />

theory or cause of action; excludes UCC warranties. No representative, theory or cause of action; excludes UCC warranties. No representative, theory or cause of action; excludes UCC warranties. No representative,<br />

employee, or agent of GAF, or any other person, has any authority <strong>to</strong> employee, or agent of GAF, or any other person, has any authority <strong>to</strong> employee, or agent of GAF, or any other person, has any authority <strong>to</strong><br />

assume for GAF any additional or other liability or responsibility. assume for GAF any additional or other liability or responsibility. assume for GAF any additional or other liability or responsibility..<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty GAF’s determination Neutral (no provision) Neutral (no provision)<br />

applicability<br />

12 Specific exclusions from 1,2,3,4,5,6,7,8,9,10,11 12,13,15,17,19,20,22,24 1, 2, 3, 4, 5, 6, 7 (not applicable <strong>to</strong> GAF insulation or GAF roof 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 (including aliphatic or<br />

coverage (see Item 12 in<br />

base), 8, 9, 10, 11, 12, 13, 15, 17, 22<br />

aromatic solvents, chlorinated hydrocarbons, turpentine, oils,<br />

Introduction)<br />

organic or inorganic polar materials), 15, 17, 19, 22.<br />

13 Wind coverage/exclusions Warranty excludes winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. GAF GAF indicates warranty covers roof damage resulting from wind speeds up The warranty excludes winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes.<br />

indicates that there is no coverage for damage caused by wind <strong>to</strong> 60 mph. Warranty excludes roof damage resulting from winds<strong>to</strong>rms GAF indicates that there is no coverage for damage caused by<br />

above 60 mph, hurricanes and <strong>to</strong>rnadoes.<br />

wind.<br />

768


14 Specific conditions <strong>to</strong> make Warranty states that cancellation of this warranty will result if the C, H, I, S. Also, guarantee states that guarantee will be canceled if Warranty states that cancellation of this warranty will result if the<br />

the warranty ineffective or roof is damaged by any cause listed as an exclusion (See Item 12 roof is damaged by any cause listed as an exclusion (See Item 12 roof is damaged by any cause listed as an exclusion (See Item<br />

null and void (see Item 14 in above) if the damage affects the integrity or water tightness of the above) if the damage affects the integrity or water tightness of the 12 above) if the damage affects the integrity or watertightness of<br />

Introduction)<br />

roof. roof and owner does not promptly make repairs following the roof.<br />

notification by GAF.<br />

15 Cost <strong>to</strong> obtain None 10 yrs: $4.00/sq; 15 yrs: $6.00/sq; 20 yrs: $8.00/sq None<br />

16 Minimum charge None 10 years: $400; 20 years: $900; 15 years: $600 None<br />

17 Ineligible structure or Private residences, walking decks, applications over buildings with Private residences, walking decks, buildings with high internal Warranty states that it does not apply <strong>to</strong> application over cold<br />

building use high internal humidity, freezer buildings or buildings used for cold humidity, freezer buildings or buildings used for cold s<strong>to</strong>rage s<strong>to</strong>rage or freezer buildings or buildings with high humidity<br />

s<strong>to</strong>rage unless approved in writing in advance by GAF unless approved in writing in advance by GAF conditions. GAF indicates that the Tri-Ply application and<br />

specification manual should be consulted.<br />

18 Pre-construction notice and Pre-installation form is submitted by contrac<strong>to</strong>r, reviewed by Pre-installation form is submitted by contrac<strong>to</strong>r, reviewed by None<br />

approval requirements Contrac<strong>to</strong>r Services department, project acceptance is faxed Contrac<strong>to</strong>r Services department, project acceptance is faxed<br />

and/or mailed back <strong>to</strong> contrac<strong>to</strong>r.<br />

and/or mailed back <strong>to</strong> contrac<strong>to</strong>r.<br />

19 Approved, authorized, or Yes Yes No<br />

licensed requirements<br />

20 Job inspection policy No on-site inspections GAF technical field representative makes on-site inspections prior <strong>to</strong> and No on-site inspections<br />

during (as required by project size and project specifications) and after<br />

application, as well as two years after issuance of warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation None; material-only guarantee Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> all leaks and workmanship None; material-only warranty<br />

obligation<br />

deficiencies for two years.<br />

22 Backed by named insurance No; GAF indicates it does not carry insurance covering its No; GAF indicates it does not carry insurance covering its No<br />

or surety guarantee obligations. guarantee obligations.<br />

23 Issuing entity manufactures GAF sells products only. GAF sells products only. GAF manufactures and sells product.<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision. No renewal provision. No renewal provision<br />

extension<br />

25 Assignability Not transferable or assignable in any manner. Assignable <strong>to</strong> another owner only if (1) request is made in writing 30 days<br />

after ownership transfer; (2) membrane is inspected and any required<br />

repairs are completed at owner’s expense; (3) proposed assignment is<br />

approved in writing by an authorized GAF technical services manager; and<br />

(4) an assignment fee of $500 is paid <strong>to</strong> GAF. Otherwise guarantee is not<br />

assignable, directly or indirectly.<br />

Not transferable or assignable in any manner.<br />

26 Special features/condition The owner must initiate and follow a 9-point maintenance program<br />

prescribed by GAF on the reverse side of guarantee including: (1)<br />

maintaining a file showing all inspections, repairs, original<br />

construction drawings and specifications; (2) inspecting roof at<br />

least semiannually; (3) inspecting roof for damage after severe<br />

weather conditions; (4) repairing non-guaranteed conditions<br />

affecting the GAF roof system; (5) removing any debris; (6)<br />

examining/reattaching loose metalwork; (7) repairing loose<br />

masonry/coping s<strong>to</strong>nes; (8) examining roof <strong>to</strong>p equipment <strong>to</strong><br />

determine if they move excessively or leak; and (9) minimize<br />

roof<strong>to</strong>p traffic.<br />

GAF shall not be responsible for or liable for any change or<br />

amendment <strong>to</strong> the GAF specifications, unless the change or<br />

amendment <strong>to</strong> the specifications is approved in writing by an<br />

authorized GAF Contrac<strong>to</strong>r Services manager.<br />

27 Executed by owner Yes; owner must sign and mail in warranty registration form within<br />

30 days of roof completion.<br />

Owner shall, at its expense, (a) perform regular inspections and<br />

Warranty applies only <strong>to</strong> Tri-Ply roofing membranes and base flashings<br />

maintenance; (b) keep records of all inspections and maintenance<br />

installed after January 1, 2000 in accordance with current specifications.<br />

performed; and © perform repairs <strong>to</strong> the roof or other building components GAF shall not be responsible for or liable for any change and/or<br />

identified during inspections by GAF as being necessary <strong>to</strong> preserve the amendment <strong>to</strong> the GAF Tri-Ply <strong>Roof</strong> specifications in regard <strong>to</strong> the<br />

integrity of the GAF roofing materials. Failure of owner <strong>to</strong> perform work construction of the roof, unless the change and/or amendment <strong>to</strong> the<br />

promptly following written notification by GAF may result in cancellation of specifications are approved in writing by an authorized GAF Contrac<strong>to</strong>r<br />

guarantee if the owner’s failure results in damage <strong>to</strong> the GAF roofing Services Manager.<br />

materials.<br />

Owner shall, at its expense, remove (and, if desired, subsequently<br />

replace) any materials and equipment that impede inspection and repair of<br />

the GAF roofing materials, such as HVAC units and satellite dishes mounted<br />

so that there is no functional access <strong>to</strong> the roof system, and precast<br />

concrete or rubber pavers, wood decking or steel grating that are installed<br />

over the GAF roofing materials.<br />

GAF shall not be responsible for or liable for any change or amendment<br />

<strong>to</strong> the GAF roof specifications in regard <strong>to</strong> the roof construction, unless the<br />

change or amendment <strong>to</strong> the specifications is approved in writing by an<br />

authorized GAF Contrac<strong>to</strong>r Services manager.<br />

In an emergency, the Owner may authorize or perform temporary repairs<br />

<strong>to</strong> minimize damage <strong>to</strong> the building or its contents. Such work will not result<br />

in the cancellation of guarantee provided that the temporary repairs are<br />

reasonable and cus<strong>to</strong>mary, and do not result in permanent damage <strong>to</strong> the<br />

GAF membrane or base flashing. Owner is responsible for all expenses<br />

associated with temporary repairs<br />

No<br />

No<br />

769


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Henry Company Henry Company Henry Company<br />

2 Title, original publication Henry Company 'Ten and Ten <strong>Roof</strong>' Membrane Warranty A Henry Company <strong>Roof</strong> Membrane Limited Warranty February 1985 <strong>Roof</strong>ing Systems & Waterproofing Limited Warranty; 09/96<br />

date, and identifying symbol, Twenty Year Full Value Warranty With Maintenance Treatment<br />

if any During Tenth Anniversary Year; February 1985<br />

3 Product, specification, or Built-up roofing specifications H4-NGC-MR, H4-I--IGC-MR, H4- Built-up roofing specifications H3-MGC-MR, H4NGC-MR, H3-IGC- Modified Plus Modified Bitumen roofing products and systems<br />

system covered IGC-GV/GN MR, H4-IGC-MR, H3-IGC-GV/GN, H4-IGC-GV/GN, H3-NPE-MR,<br />

H3-IPE-MR, H3-NPE-GV/GN, H3-IPE-GV/GN, H3-NGC-GV/GN<br />

4 Scope of coverage Material and workmanship: Henry Company warrants the roof Material and workmanship; Henry Company will Material only; Monsey Bakor warrants that it will, at its option,<br />

membrane against leaks and will cause <strong>to</strong> be repaired at no cost cause <strong>to</strong> be repaired at no cost <strong>to</strong> the building owner leaks repair or replace free of charge any Monsey Bakor products that<br />

<strong>to</strong> the building leaks occurring in the roof membrane that are due occurring in the roof membrane that are due <strong>to</strong> ordinary wear of are found <strong>to</strong> be materially defective. The warranty covers only<br />

<strong>to</strong> ordinary wear of the elements. the elements. <strong>Roof</strong> membrane does not include and warranty ex- material defects in Monsey Bakor products that cause water<br />

cludes roof insulation, vapor retarder, roof deck, drains, expansion leakage.<br />

joints, metal or plastic fittings, vents, skylights, and reflective<br />

coating.<br />

5 Length of coverage 20 years, provided owner pays for maintenance, repair, and 10 years 12 years<br />

coating determined by Henry after initial 10 years (See Conditions<br />

for Renewal or Extension.)<br />

6 Nature of remedy Henry will make or cause <strong>to</strong> be made repairs necessary <strong>to</strong> Henry will make or cause <strong>to</strong> be made any repairs necessary <strong>to</strong> Monsey Bakor's liability limited <strong>to</strong> replacement of materials and<br />

maintain the roof membrane in a watertight condition. maintain roof membrane in a watertight condition. the cost of labor necessary <strong>to</strong> maintain or res<strong>to</strong>re the surface <strong>to</strong><br />

which the Monsey Bakor product is applied in a watertight<br />

condition.<br />

7 Monetary limitations None stated Henry Company shall be discharged of all further liability whenever None stated.<br />

the cost <strong>to</strong> Henry of all covered roof membrane repairs equals<br />

warranty amount.<br />

8 Notification requirements Written notice of any material defect of the Monsey Bakor products Written notice of any material defect of the Monsey Bakor products Written notice of any material defect of the Monsey Bakor<br />

within 30 days of the defect Henry Company, 3810 Miller Park within 30 days of the defect Henry Company, 3810 Miller Park products within 30 days of the defect Henry Company, 3810<br />

Drive, Garland, TX 75042. Drive, Garland, TX 75042. Miller Park Drive, Garland, TX 75042.<br />

9 Exclusive or additional Warranty shall be the only obligation of Henry Company, with Warranty shall be the only obligation of Henry Company, with Remedy provided in the warranty is the sole and exclusive<br />

remedy respect <strong>to</strong> the roof membrane; excludes all other warranties; seeks respect <strong>to</strong> the roof membrane; excludes all other warranties; seeks remedy provided by Monsey Bakor <strong>to</strong> the owner for any and all<br />

<strong>to</strong> exclude UCC warranties <strong>to</strong> exclude UCC warranties. claims arising under, in connection with, or in any way related <strong>to</strong><br />

the Monsey Bakor products; excludes all other warranties,<br />

guarantees, conditions, and representations; excludes UCC<br />

warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (no provision) Neutral (no provision) Neutral (no provision)<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 16, 18, 20, 22, 23, 24. (Warranty also 1, 2, 3, 4, 5, 8, 9, 10, 11, 18, 22, 23. Warranty 1, 3, 4, 5, 8, 9, 11, 17, 19; also excludes normal wear and tear<br />

coverage (see Item 12 in excludes construction inside the building, including the removal or also excludes construction inside the building, including the and aesthetic diminution.<br />

Introduction) addition of walls or ceiling structures, that affects the integrity of removal or addition of walls, that influences the integrity of the roof<br />

the roof membrane.)<br />

membrane.<br />

13 Wind coverage/exclusions Warranty covers roof damage resulting from wind speeds up <strong>to</strong> 46 Warranty covers roof damage resulting from wind speeds up <strong>to</strong> 46 Monsey Bakor indicates that the warranty covers winds up <strong>to</strong><br />

miles per hour. miles per hour. fresh gales, which are defined on the Beaufort Scale as winds<br />

ranging from 39 <strong>to</strong> 46 mph. The warranty excludes roof damage<br />

from fresh gale force winds.<br />

14 Specific conditions <strong>to</strong> make B, D, F, H B, H, S B, C, H, I, R<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain $10.00/square $10.00/square None<br />

16 Minimum charge $1,000 $1,000 Minimum roof size of 50 squares<br />

770


17 Ineligible structure or Cold-s<strong>to</strong>rage facilities and most apartment buildings and Cold-s<strong>to</strong>rage and most apartment buildings and condominiums; all None<br />

building use condominiums. All structures and locations subject <strong>to</strong> approval by structures and locations subject <strong>to</strong> approval by Henry Company.<br />

Henry Company.<br />

18 Pre-construction notice and Prior approval issued by execution of warranty application form Prior approval issued by execution of warranty application form None<br />

approval requirements and preconstruction notice 72 hours in advance. and preconstruction notice 72 hours in advance<br />

19 Approved, authorized, or Yes Yes No<br />

licensed requirements<br />

20 Job inspection policy Henry inspec<strong>to</strong>r makes on-site inspections prior <strong>to</strong>, during (daily <strong>to</strong> Henry inspec<strong>to</strong>r makes on-site inspections prior <strong>to</strong> and during No on-site inspections<br />

periodical), and after application, as well as two years after application (daily <strong>to</strong> periodical) and after application, as well as two<br />

issuance of warranty; $1.00/square charge.<br />

years after issuance of warranty; $1.00/square charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workman- None; material-only warranty<br />

obligation for two years. ship deficiencies for two years.<br />

22 Backed by named insurance No; Henry Company indicates that it does not carry insurance No; Henry Company indicates that it does not carry insurance No; Monsey Bakor indicates that it carries umbrella liability<br />

or surety covering its warranty obligations. covering its warranty obligations. insurance covering its warranty obligations in the amount of $10<br />

million.<br />

23 Issuing entity manufactures Henry Company manufactures and sells product. Henry Company manufactures and sells product. Monsey Bakor manufacturers and sells the product<br />

and/or sells products<br />

24 Conditions for renewal or After 10 years, warranty can be extended for additional 10 years. No renewal provision No renewal provision<br />

extension<br />

During tenth year following installation, a Henry representative will<br />

inspect the roof and report any routine maintenance determined by<br />

Henry Company <strong>to</strong> be necessary <strong>to</strong> maintain integrity of the roof<br />

membrane and flashing for the remaining 10-year period of the<br />

warranty term. The cost of such repair and coating will be the<br />

responsibility of the building owner; no additional warranty fee.<br />

25 Assignability Warranty may be transferred <strong>to</strong> a new building owner with prior Transferable <strong>to</strong> new building owner, provided the The warranty is not assignable without Monsey Bakor's prior<br />

written consent of Henry Company, which consent shall not be use <strong>to</strong> which the new owner puts the building is approved by Henry written consent.<br />

unreasonably withheld; consent shall not be determined <strong>to</strong> be un- Company. Building owner shall notify Henry Company prior <strong>to</strong><br />

reasonably withheld if the use of the building by any owner is making any transfer of ownership.<br />

materially different from the use of the prior building owner.<br />

26 Special features/condition In the event an emergency condition exists requiring immediate In the event an emergency condition exists requiring immediate Pursuant <strong>to</strong> the warranty, the owner authorizes Monsey Bakor <strong>to</strong><br />

repair <strong>to</strong> avoid significant damage <strong>to</strong> the building, the building repair <strong>to</strong> avoid significant damage <strong>to</strong> owner, the owner may make investigate or cause <strong>to</strong> be investigated the alleged material<br />

owner may make such temporary repairs as may be necessary <strong>to</strong> temporary repairs as may be essential and such action shall not defect of the Monsey Bakor products on the owner's behalf.<br />

repair such leaks and such action shall not void warranty. In the void warranty Should the alleged material defect or the remedy sought by the<br />

event the building owner fails <strong>to</strong> proceed with maintenance<br />

owner lie outside the scope of the warranty, the owner agrees <strong>to</strong><br />

recommended by Henry Company after 10 years, Henry Company<br />

promptly reimburse Monsey Bakor for the cost of any such<br />

shall be discharged from all further obligation under warranty at<br />

investigation, including repair costs.<br />

the end of the 10th year of warranty. The owner shall bear any expense of removing and replacing<br />

traffic walkways or other structures <strong>to</strong> allow repairs <strong>to</strong> be made<br />

when necessary<br />

27 Executed by owner No No Yes; the warranty does not come in<strong>to</strong> force until receipt of a signed copy<br />

by Monsey Bakor and owner.<br />

771


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Henry Company Henry Company Henry Company<br />

2 Title, original publication Limited <strong>Roof</strong>ing & Waterproofing Product Warranty; 09/96 Limited <strong>Roof</strong>ing & Waterproofing Product Warranty; 09/96 Gold Seal <strong>Roof</strong>ing & Waterproofing Membrane Warranty; 09/96<br />

date, and identifying symbol,<br />

if any<br />

3 Product, specification, or Modified Plus Modified Bitumen roofing products and systems Modified Plus Modified Bitumen roofing products and systems Modified Plus Modified Bitumen roofing products and systems<br />

system covered<br />

4 Scope of coverage Material only; Monsey Bakor warrants that the Monsey Bakor Material only; Monsey Bakor warrants that the Monsey Bakor Material and workmanship; Monsey Bakor warrants that the<br />

product, when prepared and applied in accordance with product, when prepared and applied in accordance with membrane system, including field and flashing membranes, will<br />

specifications and directions and used under normal service specifications and directions and used under normal service remain in a watertight condition. Only water leakage through<br />

conditions, will not break down or disintegrate. conditions, will not break down or disintegrate. the membrane shall be considered a defect covered under the<br />

warranty.<br />

5 Length of coverage 12 years 12 years 12, 15, or 20 years (Monsey Bakor indicates that warranty<br />

coverage depends upon specification and specific product used.<br />

Standard term is 12 years).<br />

6 Nature of remedy Monsey Bakor shall refund <strong>to</strong> the owner all or part of the original Monsey Bakor shall refund <strong>to</strong> the owner all or part of the original Monsey Bakor's liability limited <strong>to</strong> replacement of materials and<br />

cost of the product based upon a prorating schedule. cost of the product based upon a prorating schedule. cost of labor necessary <strong>to</strong> maintain or res<strong>to</strong>re the surface <strong>to</strong><br />

which the membrane is applied in a watertight condition<br />

7 Monetary limitations Refund <strong>to</strong> the owner shall be determined by multiplying the original Refund <strong>to</strong> the owner shall be determined by multiplying the original None stated<br />

cost of the product times (by) the unexpired fraction of the cost of the product times (by) the unexpired fraction of the<br />

warranty period.<br />

warranty period.<br />

8 Notification requirements Written notice of any material defect in the Monsey Bakor products Written notice of any material defect in the Monsey Bakor products Written notice of any material defect in the Monsey Bakor<br />

within 30 days of the defect <strong>to</strong> Henry Company, 3810 Miller Park within 30 days of the defect <strong>to</strong> Henry Company, 3810 Miller Park products within 30 days of the defect <strong>to</strong> Henry Company, 3810<br />

Drive, Garland, TX 75042 Drive, Garland, TX 75042 Miller Park Drive, Garland, TX 75042<br />

9 Exclusive or additional The warranty is in lieu of and excludes all other warranties, The warranty is in lieu of and excludes all other warranties, Remedy provided in the warranty is the sole and exclusive<br />

remedy guarantees, conditions, and representations; excludes UCC guarantees, conditions, and representations; excludes UCC remedy provided by Monsey Bakor <strong>to</strong> the owner for any and all<br />

warranties. warranties. claims arising under, in connection with, or in any way related <strong>to</strong><br />

the membrane or its installation; excludes all other warranties,<br />

guarantees, conditions, and representations; excludes UCC<br />

warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (no provision) Neutral (no provision) Neutral (no provision)<br />

applicability<br />

12 Specific exclusions from 1, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 19, 21; also excludes 1, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 19, 21; also excludes 1, 3, 4, 5, 6, 8, 11, 12, 17; also excludes normal wear and tear<br />

coverage (see Item 12 in deterioration of flashings where water has been allowed <strong>to</strong> enter deterioration of flashings where water has been allowed <strong>to</strong> enter and aesthetic diminution.<br />

Introduction) behind the base flashing from sources other than through the behind the base flashing from sources other than through the<br />

membrane or base flashing.<br />

membrane or base flashing.<br />

13 Wind coverage/exclusions No coverage for damage caused by wind No coverage for damage caused by wind Monsey Bakor indicates that warranty covers roof damage<br />

resulting from wind speeds up <strong>to</strong> 55 mph. The warranty<br />

excludes damage caused by winds exceeding 55 mph as<br />

determined by the U.S. or Canadian Weather Bureau,<br />

depending on project location.<br />

14 Specific conditions <strong>to</strong> make B, C, H, I, R B, C, H, I, R B, C, H, I, R<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain None None 12 yrs: $6.00/sq; 15 yrs: $10.00/sq; 20 yrs: $15.00 sq<br />

16 Minimum charge None None 12 years: $300; 15 years: $500; 20 years: $750<br />

17 Ineligible structure or None None Cold-s<strong>to</strong>rage facilities; all residential buildings other than<br />

building use<br />

multiple dwellings<br />

772


18 Pre-construction notice and None None The contrac<strong>to</strong>r must submit details of project, including deck<br />

approval requirements<br />

construction, vapor retarder, insulation materials, and all<br />

flashing details prior <strong>to</strong> installation and obtain approval.<br />

19 Approved, authorized, or No No Yes<br />

licensed requirements<br />

20 Job inspection policy No on-site inspections No on-site inspections Monsey Bakor personnel make on-site inspections prior <strong>to</strong>,<br />

during (as often as required), and after application, as well as<br />

two years following completion; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation None; material-only warranty None; material-only warranty The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

obligation<br />

deficiencies for two years.<br />

22 Backed by named insurance No; Monsey Bakor indicates that it carries umbrella liability No; Monsey Bakor indicates that it carries umbrella liability No; Monsey Bakor indicates that it carries umbrella liability<br />

or surety insurance covering its warranty obligations in the amount of $10 insurance covering its warranty obligations in the amount of $10 insurance covering its warranty obligations in the amount of $10<br />

million. million. million.<br />

23 Issuing entity manufactures Monsey Bakor manufacturers and sells the product Monsey Bakor manufacturers and sells the product Monsey Bakor manufacturers and sells the product.<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability The warranty is not assignable without Monsey Bakor's prior The warranty is not assignable without Monsey Bakor's prior The warranty is not assignable without Monsey Bakor's prior<br />

written consent. written consent. written consent.<br />

26 Special features/condition Pursuant <strong>to</strong> the warranty, the owner authorizes Monsey Bakor <strong>to</strong> Pursuant <strong>to</strong> the warranty, the owner authorizes Monsey Bakor <strong>to</strong> Pursuant <strong>to</strong> the warranty, the owner authorizes Monsey Bakor <strong>to</strong><br />

investigate or cause <strong>to</strong> be investigated the alleged material defect investigate or cause <strong>to</strong> be investigated the alleged material defect investigate or cause <strong>to</strong> be investigated the alleged material<br />

of the Monsey Bakor products on the owner's behalf. Should the of the Monsey Bakor products on the owner's behalf. Should the defect of the Monsey Bakor products on the owner's behalf.<br />

alleged material defect or the remedy sought by the owner lie alleged material defect or the remedy sought by the owner lie Should the alleged material defect or the remedy sought by the<br />

outside the scope of the warranty, the owner agrees <strong>to</strong> promptly outside the scope of the warranty, the owner agrees <strong>to</strong> promptly owner lie outside the scope of the warranty, the owner agrees <strong>to</strong><br />

reimburse Monsey Bakor for the cost of any such investigation, reimburse Monsey Bakor for the cost of any such investigation, promptly reimburse Monsey Bakor for the cost of any such<br />

including repair costs. including repair costs. investigation, including repair costs.<br />

Monsey Bakor does not authorize any person, including its Monsey Bakor does not authorize any person, including its The owner shall bear any expense of removing and replacing<br />

representatives, <strong>to</strong> make any representation or <strong>to</strong> offer any representatives, <strong>to</strong> make any representation or <strong>to</strong> offer any traffic walkways or other structures <strong>to</strong> allow repairs <strong>to</strong> be made<br />

warranty, condition or guarantee in respect <strong>to</strong> the product other warranty, condition or guarantee in respect <strong>to</strong> the product other when necessary.<br />

than this warranty.<br />

than this warranty.<br />

27 Executed by owner Yes; the warranty does not come in<strong>to</strong> force until receipt of a signed Yes; the warranty does not come in<strong>to</strong> force until receipt of a signed Yes; the warranty does not come in<strong>to</strong> force until receipt of a<br />

copy by Monsey Bakor and owner. copy by Monsey Bakor and owner. signed copy by Monsey Bakor and owner.<br />

773


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Herbert Malarkey <strong>Roof</strong>ing Company Hyload, Inc. Hyload, Inc.<br />

2 Title, original publication date, Malarkey <strong>Roof</strong>ing System Warranty High Performance <strong>Roof</strong> Systems 10 Year Commercial Warranty High Performance <strong>Roof</strong> Systems 15 Year Commercial<br />

and identifying symbol, if any Material and Workmanship; July 1, 1996; HW070196-10LM Warranty, Material and Workmanship; Oc<strong>to</strong>ber 1, 1996;<br />

HW1001-196-15LM<br />

3 Product, specification, or system All eligible built-up roofing specifications with a #502 mineral cap sheet; Hyload 150E, Hyload 250E, Hyload WS, Hyload SAM, ALPROOF, Hyload H150E, Hyload H250E, Hyload WS, ALPROOF,<br />

covered modified bitumen specifications #601 SBS mineral cap sheet, #625 Paragon ALPROOF CP, ALPSAM WS, ASPSAM; minimum of one ply of ALPROOF CP, ALPSAM WS; minimum of two plies of Type IV<br />

SBS mineral cap sheet, #650 Panoply SBS mineral cap sheet, #917 SBS Type IV felt must be installed prior <strong>to</strong> Hyload membrane. felt must be installed prior <strong>to</strong> Hyload membranbe.<br />

mineral cap sheet, #919 SBS smooth cap sheet<br />

4 Scope of coverage Material and workmanship; Malarkey warrants that the roof system will Material and workmanship; Hyload warrants that the Hyload Hyload warrants tha the Hyload roofing membrane will not leak<br />

remain in a watertight condition or Malarkey will initiate repairs at its own roofing membrane will not leak and cuase water infiltration in<strong>to</strong> the and cause water infiltration in<strong>to</strong> the building as a result of nay<br />

expense if required as a result of deterioration of the Malarkey roofing building as a result of any defect int he design or manufacture of defect in the design or manufacture of the membrane, or as a<br />

membrane or base flashing system resulting from ordinary wear and tear of the membrane, or as a result of defective workmanship in the result of defective workmanship inthe applicationof the<br />

the elements; workmanship on the part of the Malarkey approved roofing application of the membrane. membrane.<br />

contrac<strong>to</strong>r in application of the Malarkey roofing membrane or base flashing<br />

system; blisters, bare spots, fishmouths, wrinkles, or ridges in the roof<br />

system; splits in the Malarkey roofing membrane not caused by structural<br />

movement or failure or movement of any material underlying the roofing<br />

membrane or base flashing; or slippage of the roofing membrane or base<br />

flashing<br />

5 Length of coverage 10, 12, 15, or 20 years 10 years 15 years<br />

6 Nature of remedy Malarkey will be liable only for the cost of repair of the existing roof Hyload will, via such methods as Hyload determines fit, effect the Hyload will, via such methods as Hyload determines fit, effect<br />

membrane or installation of a replacement roof membrane; Malarkey's sole repair of leaks as its expense. the repair of leaks as its expense.<br />

liability resulting from any failure of the roof system shall be cost of repair or<br />

replacement.<br />

7 Monetary limitations Warranty includes space for Malarkey's maximum liability <strong>to</strong> be inserted. Hyload’s obligation over the lifetime of the warranty shall not Hyload’s obligation over the lifetime of the warranty shall not<br />

(Malarkey indicates that 10-year warranty can be purchased with a exceed the retail price of Hyloads roofing materials used in the exceed the retail price of Hyloads roofing materials used in the<br />

$35/square or $50/square maximum liability limitation or can be purchased original installation of the roof. original installation of the roof.<br />

without a maximum Malarkey liability limitation and that 12, 15, and 20 year<br />

warranties can be obtained without a maximum Malarkey liability limitation.)<br />

8 Notification requirements Written notification by registered or certified mail within 30 days after the Immediate notification by telephone <strong>to</strong> Hyload upon the discovery Immediate notification by telephone <strong>to</strong> Hyload upon the<br />

leak is discovered or should, by reasonable diligence, have been of any leak in the membrane and written confirmation of the leak discovery of any leak in the membrane and written confirmation<br />

discovered <strong>to</strong> Malarkey <strong>Roof</strong>ing Company, P.O. Box 17217, Portland, OR within 15 days thereafter. of the leak within 15 days thereafter.<br />

97217<br />

9 Exclusive or additional remedy Warranty is in lieu of and excludes all other warranties, guarantees or Remedy in warranty is owner’s sole and exclusive remedy so that Remedy in warranty is owner’s sole and exclusive remedy so<br />

obligations; warranty seeks <strong>to</strong> exclude UCC warranties Hyload’s repair of leaks constitutes fulfillment of all its obligations; that Hyload’s repair of leaks constitutes fulfillment of all its<br />

excludes other guarantees and warranties’ excludes UCC obligations; excludes other guarantees and warranties’ excludes<br />

warranties.<br />

UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (no provision) Hyoad’s determination Hyoad’s determination<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 12, 13, 15, 17, 23 1, 3, 4, 5, 7, 9, 10, 12, 18 1, 3, 4, 5, 7, 9, 10, 12, 18<br />

coverage (see Item 12 in<br />

Introduction)<br />

13 Wind coverage/exclusions Warranty excludes winds<strong>to</strong>rms, hurricanes, and <strong>to</strong>rnadoes. Malarkey Warranty excludes hurricanes, gales and <strong>to</strong>rnadoes. Warranty excludes hurricanes, gales and <strong>to</strong>rnadoes.<br />

indicates that there is no coverage for damage caused by wind.<br />

14 Specific conditions <strong>to</strong> make the C B, C, J, M, R, S. Warranty also becomes null and void if subsequent work is B, C, J, M, R, S. Warranty also becomes null and void if subsequent<br />

warranty ineffective or null and doen at or through the Hyload membrane. work is doen at or through the Hyload membrane.<br />

void (see Item 14 in Introduction)<br />

15 Cost <strong>to</strong> obtain 10 years (with $35/sq monetary limitation): $4.00/sq; $9.00/square $12.00/square<br />

10 years (with $50/sq monetary limitation): $4.50/sq;<br />

10 years (without monetary limitation): $6.00/sq;<br />

12 years: $8.00/sq; 15 years: $10.00/sq; 20 years: $15.00/sq<br />

16 Minimum charge 10 yrs (with $35/sq monetary limitation): $400; $900 $1200<br />

10 yrs (with $50/sq monetary limitation): $450;<br />

10 yrs (without monetary limitation): $600;<br />

12 yrs: $800; 15 yrs: $1,000; 20 yrs: $1,500<br />

774


17 Ineligible structure or building<br />

use<br />

Cold s<strong>to</strong>rage, single family Residential Residential<br />

18 Pre-construction notice and<br />

approval requirements<br />

Warranty application must be filed with and approved by Malarkey prior <strong>to</strong><br />

job start.<br />

Contrac<strong>to</strong>r is required <strong>to</strong> pay warranty fee, complete warranty<br />

request from outlining membrane installation and obtain approval<br />

from Hyload prior <strong>to</strong> beginning installation.<br />

Contrac<strong>to</strong>r is required <strong>to</strong> pay warranty fee, complete warranty<br />

request from outlining membrane installation and obtain<br />

approval from Hyload prior <strong>to</strong> beginning installation.<br />

19 Approved, authorized, or licensed<br />

requirements<br />

Yes Yes Yes<br />

20 Job inspection policy Malarkey representative makes inspections prior, during, and after<br />

application depending upon size; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation<br />

obligation<br />

22 Backed by named insurance or<br />

surety<br />

23 Issuing entity manufactures<br />

and/or sells products<br />

Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> all leaks and any defects for two<br />

years.<br />

No; Malarkey indicates that it does not carry insurance covering its warranty<br />

obligations.<br />

Hyload technical department representative makes on-site<br />

inspections after completion of installation prior <strong>to</strong> issuance of<br />

warranty and two years after issuance of warranty; no charge.<br />

The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> material and<br />

workmanshuip deficiencies for 2 yrs.<br />

No; Hyload indicates it does not carry insurance covering its<br />

warranty obligations.<br />

Hyload technical department representative makes on-site<br />

inspections after completion of installation prior <strong>to</strong> issuance of<br />

warranty and two years after issuance of warranty; no charge.<br />

The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> material and<br />

workmanshuip deficiencies for 2 yrs.<br />

No; Hyload indicates it does not carry insurance covering its<br />

warranty obligations.<br />

Malarkey manufactures and sells product Hyload manufactures and sells the product. Hyload manufactures and sells the product.<br />

24 Conditions for renewal or<br />

extension<br />

The owner has option <strong>to</strong> renew for ___ years by requesting inspection by<br />

Malarkey. Malarkey inspects and advises owner of necessary maintenance<br />

work <strong>to</strong> be performed by approved contrac<strong>to</strong>r at owner's expense. If work<br />

performed within 90 days of expiration and Malarkey, then accepts the roof,<br />

upon payment of charge not <strong>to</strong> exceed the current initial<br />

charge, the warranty will be renewed.<br />

25 Assignability The warranty is transferable provided that Malarkey is notified by the<br />

original owner at least seven days prior <strong>to</strong> transfer. Malarkey schedules a<br />

roof inspection. Any repairs covered under the warranty will be paid for by<br />

Malarkey; the owner pays for maintenance items and/or incidental repairs<br />

found <strong>to</strong> be required. Once maintenance and/or repairs have been<br />

completed by a Malarkey approved roofing contrac<strong>to</strong>r, warranty transfer will<br />

be completed after payment of a $500 transfer fee.<br />

26 Special features/condition Warranty is only valid when Malarkey pre-approved asphalt, base flashing<br />

system, and roof insulation when the roof is insulated are used.<br />

No renewal provision<br />

The warranty is not assignable.<br />

The warranty shall be governed by the laws ofthe state of Ohio,<br />

excluding principles of conflicts of law. All actions arising under<br />

the warranty shall be brought in the court of commono please for<br />

Meidan County, Ohio. If the owner does not make repairs that are<br />

not covered by the warranty within 30 days of notice from Hyload,<br />

warranty shall au<strong>to</strong>matically terminate.<br />

No renewal provision<br />

The warranty is not assignable.<br />

The warranty shall be governed by the laws ofthe state of Ohio,<br />

excluding principles of conflicts of law. All actions arising under<br />

the warranty shall be brought in the court of commono please<br />

for Meidan County, Ohio. If the owner does not make repairs<br />

that are not covered by the warranty within 30 days of notice<br />

from Hyload, warranty shall au<strong>to</strong>matically terminate.<br />

27 Executed by owner No No No<br />

775


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Hyload, Inc. Hyload, Inc. International Diamond <strong>Roof</strong>ing Systems, Inc. (IDS)<br />

2 Title, original publication High Performance <strong>Roof</strong>ing Systems 15 Year Commercial High Performance <strong>Roof</strong>ing Systems 10 Year Commercial Limited Workmanship Warranty; Revised 12/95<br />

date, and identifying symbol, Warranty; July 1, 1996; HW0701-6-15YM<br />

Warranty; July 1, 1996; HW070196-10YM<br />

if any<br />

3 Product, specification, or Hyload H150E, Hyload 250E, Hyload WS, ALPROOF, ALPROF Hyload 150E, Hyload 250E, Hyload WS, Hyload, SAM, Diamond 105, Seal-A-Plate, FM Bar, Ballasted, Bonded Plate,<br />

system covered CP, ASPSAM WS; minimum of two plies of Type IV felts must be ALPROOF, ALPROOF CP, ALPSAM WS, ALPSAM; minimum of 135 Totally Adhered, Reinforced<br />

installed prior <strong>to</strong> Hyload membrane.<br />

one ply of Type IV velt must be installed prior <strong>to</strong> Hyload membrane<br />

4 Scope of coverage Material only; Hyload warrants roofing membrane will not leak and cause Material only; Hyload warrants roofing membrane will not leak and Material and workmanship; IDS warrants that it will repair<br />

cause water infiltration in<strong>to</strong> the building as a result of any defect in improper workmanship of any installed IDS product in the<br />

water infiltration in<strong>to</strong> the building as a result of any defect in the design and<br />

manufacture of the membrane<br />

the design and manufacture of the membrane.<br />

original IDS roofing system. The IDS roofing system is limited<br />

<strong>to</strong> and includes only the IDS EPDM vulcanized roofing<br />

membrane, flashing, adhesives, and other IDS accessories<br />

purchased from IDS or its distribu<strong>to</strong>rs, utilized in the installation<br />

and installed according <strong>to</strong> IDS installation instructions. (See<br />

Special Features/Conditions.)<br />

5 Length of coverage 15 years<br />

10 years 10 years workmanship, 15 years materials<br />

6 Nature of remedy Hyload will, via such methods as Hyload determines fit, effect the Hyload will, via such methods as Hyload determines fit, effect the<br />

repair of leaks at its expense.<br />

repair of leaks at its expense.<br />

IDS will repair improper workmanship of any installed product in the original IDS<br />

roof system. The owner's sole remedy is limited <strong>to</strong> replacement of the defective<br />

IDS product; the method of repair is sole determination of IDS. The owner's sole<br />

remedies and IDS' liabilities and obligations shall be limited <strong>to</strong> re-placement of the<br />

defective IDS product by repair or substitution of new material.<br />

7 Monetary limitations Hyloads obligation over the lifetime of the warranty shall not exceed the Hyloads obligation over the lifetime of the warranty shall not exceed the IDS' obligation <strong>to</strong> remedy defects shall not exceed the original cost of IDS<br />

retail price of the Hyload roofing materials used in the original installation of retail price of the Hyload roofing materials used in the original installation of materials as charged by IDS.<br />

the roof.<br />

the roof.<br />

8 Notification requirements Immediate notification by telephone <strong>to</strong> Hyload upon the discovery of any Immediate notification by telephone <strong>to</strong> Hyload upon the discovery of any Written notification within 30 days of discovery of any defect in the IDS<br />

leak in the membrane and written confirmation of the leak within 15 days leak in the membrane and written confirmation of the leak within 15 days roofing system by certified mail, return receipt requested, <strong>to</strong> IDS at 5110<br />

thereafger. thereafger. Angola Road, Toledo, OH 43615<br />

9 Exclusive or additional remedy Remedy in warranty is owner’s sole and exclusive remedy so that Hyload’s Remedy in warranty is owner’s sole and exclusive remedy so that Hyload’s The warranty replaces and excludes all other warranties; remedy stated<br />

repair of leaks constitutes fulfillment of all its obligations; excludes other repair of leaks constitutes fulfillment of all its obligations; excludes other in warranty is the sole and exclusive remedy; excludes UCC warranties.<br />

guarantees and warranties’ excludes UCC warranties. guarantees and warranties’ excludes UCC warranties. The warranty states: The building owners sole remedy is <strong>to</strong> file a<br />

claim against our product liability or completed operations for any<br />

underlying materials or any other damages whatsoever. The products<br />

must be proven defective scientifically by certified labora<strong>to</strong>ries.<br />

10 Inclusion of consequential<br />

damages<br />

11 Determination of warranty<br />

applicability<br />

12 Specific exclusions from<br />

coverage (see Item 12 in<br />

Introduction)<br />

No No No<br />

Hyoad’s determination Hyoad’s determination IDS’s determination<br />

1, 3, 4, 5, 7, 9, 10, 12, 18, 19, 20 1, 3, 4, 5, 7, 9, 10, 12, 18, 19, 20 1, 2, 3, 4, 5, 6, 7, 10, 11, 12 (including those items contained in IDS <strong>Roof</strong>ing Care<br />

and Maintenance Guide), 13, 16, 17, 18, 19, 24. (The warranty also excludes<br />

damage or loss caused by pests, insect infestation, ice s<strong>to</strong>rm or any winds<strong>to</strong>rm or<br />

occurrence covered by fire and winds<strong>to</strong>rm insurance, including subrogation<br />

claims.)<br />

13 Wind coverage/exclusions Warranty excludes hurricanes, gales and <strong>to</strong>rnadoes. Warranty excludes hurricanes, gales and <strong>to</strong>rnadoes. The warranty excludes winds<strong>to</strong>rms, wind gusts/gales, hurricanes, and <strong>to</strong>rnadoes.<br />

IDS indicates that the warranty covers wind speeds up <strong>to</strong> Beaufort Scale 8, which<br />

starts at 39 mph. The plate bond system is not wind uplift rated. (See Special<br />

Features/Conditions.)<br />

14 Specific conditions <strong>to</strong> make the<br />

warranty ineffective or null and<br />

void (see Item 14 in Introduction)<br />

B, C, J, M, R, S. Warranty also becomes null and void if subsequent work is B, C, J, M, R, S. Warranty also becomes null and void if subsequent work is C, M, N, S<br />

doen at or through the Hyload membrane.<br />

doen at or through the Hyload membrane.<br />

15 Cost <strong>to</strong> obtain $8.00/square $6.00/square $8.00/square<br />

16 Minimum charge $800 $600 10 years: $500, 15 years: $600<br />

17 Ineligible structure or building<br />

use<br />

Residential Residential The warranty states that IDS shall have no obligation if building is used<br />

for noncommercial purposes, such as residential, personal, family, or<br />

household purposes.<br />

776


18 Pre-construction notice and<br />

approval requirements<br />

Contrac<strong>to</strong>r is required <strong>to</strong> pay warranty fee, complete warranty request from Contrac<strong>to</strong>r is required <strong>to</strong> pay warranty fee, complete warranty request from Prior <strong>to</strong> the job commencing, the contrac<strong>to</strong>r submits an application <strong>to</strong><br />

outlining membrane installation and obtain approval from Hyload prior <strong>to</strong> outlining membrane installation and obtain approval from Hyload prior <strong>to</strong> install IDS roofing systems. Upon completion, the contrac<strong>to</strong>r submits<br />

beginning installation. beginning installation. notice of completion and request for warranty<br />

19 Approved, authorized, or licensed<br />

requirements<br />

Yes<br />

Yes<br />

20 Job inspection policy No on-site inspections No on-site inspections The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies<br />

for two years.<br />

21 Contrac<strong>to</strong>r’s post-installation<br />

obligation<br />

22 Backed by named insurance or<br />

surety<br />

23 Issuing entity manufactures<br />

and/or sells products<br />

Although this is a material-only warranty, contrac<strong>to</strong>r is obligated <strong>to</strong> make Although this is a material-only warranty, contrac<strong>to</strong>r is obligated <strong>to</strong> make No; IDS indicates that it does not carry insurance covering its warranty<br />

repairs <strong>to</strong> material and workmanshuip deficiencies for 2 yrs. repairs <strong>to</strong> material and workmanshuip deficiencies for 2 yrs. obligations.<br />

No; Hyload indicates it does not carry insurance covering its warranty No; Hyload indicates it does not carry insurance covering its warranty IDS field technical department will make on-site inspections prior <strong>to</strong> and<br />

obligations. obligations. during application upon request. IDS makes inspection after completion<br />

prior <strong>to</strong> issuance of warranty, as well as two years after issuance of<br />

warranty; no charge. If a second inspection is required, inspection<br />

charge is $350/day plus $0.26 per mile.<br />

Hyload manufactures and sells the product. Hyload manufactures and sells the product. IDS manufactures and sells the product.<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability The warranty is not assignable. The warranty is not assignable. The warranty is not transferable<br />

26 Special features/condition The warranty shall be governed by the laws ofthe state of Ohio, The warranty shall be governed by the laws ofthe state of Ohio,<br />

excluding principles of conflicts of law. All actions arising under excluding principles of conflicts of law. All actions arising under<br />

the warranty shall be brought in the court of commono please for the warranty shall be brought in the court of commono please for<br />

Meidan County, Ohio. If the owner does not make repairs that are Meidan County, Ohio. If the owner does not make repairs that are<br />

not covered by the warranty within 30 days of notice from Hyload, not covered by the warranty within 30 days of notice from Hyload,<br />

warranty shall au<strong>to</strong>matically terminate.<br />

warranty shall au<strong>to</strong>matically terminate.<br />

Although the warranty states that it covers workmanship of any installed<br />

IDS product, the warranty also states: The Owner's roofing applica<strong>to</strong>r is<br />

responsible for workmanship for the first two (2) years of this warranty or<br />

any defective workmanship known or unknown for the life of this warranty.<br />

The buyer agrees <strong>to</strong> indemnify and save IDS harmless against any claims<br />

arising out of the sale or installation of defective workmanship. In the<br />

limitations section, the warranty states: IDS is under no obligation <strong>to</strong><br />

issue a warranty on any job until an affidavit is signed by the building<br />

owner and the roofing contrac<strong>to</strong>r stating that the job was done with IDS<br />

material, specifications, and details. IDS warranty is clearly limited <strong>to</strong> the<br />

repair of IDS material if defective and the repair of the workmanship if it is<br />

made defective by the defective material. Thus, the warranty is<br />

ambiguous as <strong>to</strong> whether it covers both material and workmanship of<br />

contrac<strong>to</strong>r.<br />

All legal actions against IDS must be noticed and venued in Toledo,<br />

Lucas County, Ohio and Ohio law shall apply.<br />

The warranty states: The building owners sole remedies on the<br />

above conditions and limitation of recovery on any and all claims will be<br />

filed against IDS insurance carrier. Any dispute which cannot be settled<br />

within the terms and conditions of this warranty limits the building owners<br />

recovery <strong>to</strong> the realms of our insurance policy and/or our suppliers,<br />

and/or his agents.<br />

If the courts find the warranty legally binding or non-binding between<br />

IDS and the owner, then the UCC statute of limitations applies in lieu of<br />

the warranty in its entirety.<br />

The warranty states: All parties must except [sic] industry standards,<br />

state of the art technology, FM (Fac<strong>to</strong>ry Mutual), UL (Underwriters<br />

Labora<strong>to</strong>ries), and ASTM testing (as published by them) as the standard<br />

that is excepted [sic] by the industry and all parties with no deviations as<br />

tested by IDS.<br />

The official weather report is the nearest airport or the national<br />

weather bureau. If there are damaging winds recorded at the airport and<br />

wind damage is found on the building, the owner's insurance will be<br />

responsible for the repair of the roofing system. If the owner's insurance<br />

denies coverage for the wind damage, the owner will hold IDS harmless,<br />

along with the other terms, conditions, and limitations of warranty. Note:<br />

Ground speed winds must be calculated and multiplied by three in order<br />

<strong>to</strong> determine the effect the wind has on a system.<br />

If a defect is not caused by workmanship, IDS will advise of the type<br />

and/or extent of repairs required <strong>to</strong> be made at owner's expense by a<br />

qualified applica<strong>to</strong>r; all investigation and repair costs are the owner's<br />

responsibility.<br />

27 Executed by owner No No Yes; warranty must be signed, dated, and returned <strong>to</strong> IDS at its<br />

office in Toledo, Ohio not later than 30 days after receipt.<br />

777


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity International Diamond <strong>Roof</strong>ing Systems, Inc. (IDS) Johns Manville International, Inc. (JM) Johns Manville International, Inc. (JM)<br />

2 Title, original publication<br />

date, and identifying symbol,<br />

if any<br />

3 Product, specification, or<br />

system covered<br />

“Limited Ten Year Membrane Only Warranty (Prorated)”; Revised 12/95 "Gold Shield <strong>Roof</strong>ing System Guarantee"; September; JM-645-2 (9/97), RS- "Gold Shield <strong>Roof</strong>ing System Guarantee"; September 1997; JM-645-2<br />

7082 11-97 (9/97), RS-7082 11/97<br />

Diamond 105, Seal-A-Plate, FM Bar, Ballasted, Bonded Plate, 135 Totally APP Modified Bitumen Products: 4S, 4.5S, 4MFR, Bicor S, Bicor MRR, BUR Specifications: 4GIS, 4GIG, 5GIC, 4GNS, 4GNG, with use of<br />

Adhered, Reinforced Tricor S, Tricor MFR, when applied over one or two plies GlasPly Premier Felts; DynaKap Modified Bitumen Specifications: 3CID,<br />

3CIG, 3FID, (See Special Features/Conditions), APP Modified Bitumen<br />

Specifications: 3CIN-W, 3PIN-W.<br />

4 Scope of coverage Material only. IDS warrants that the IDS EPDM vulcanized roofing Material and workmanship; JM guarantees that it will pay for the materials Material and workmanship; JM guarantees that it will pay for the materials<br />

membrane will not deteriorate <strong>to</strong> the point of causing leaks through the and labor required <strong>to</strong> promptly repair the roofing system <strong>to</strong> return it <strong>to</strong> a and labor required <strong>to</strong> promptly repair the roofing system <strong>to</strong> return it <strong>to</strong> a<br />

membrane due <strong>to</strong> normal weathering. Warranty applies only <strong>to</strong> the IDS watertight condition if leaks occur due <strong>to</strong> ordinary wear and tear or watertight condition if leaks occur due <strong>to</strong> ordinary wear and tear or<br />

EPDM vulcanized roofing membrane utilized in the installation and installed deficiencies in any or all of the component materials of the <strong>Roof</strong>ing System deficiencies in any or all of the component materials of the <strong>Roof</strong>ing<br />

according <strong>to</strong> IDS' installation instructions and does not apply <strong>to</strong> labor, or workmanship deficiencies in the application of the <strong>Roof</strong>ing System. System or workmanship deficiencies in the application of the <strong>Roof</strong>ing<br />

materials, or any other item. <strong>Roof</strong>ing System components are JM membrane, flashing, insulation, and System. <strong>Roof</strong>ing System components are JM membrane, flashing,<br />

accessories; all other components of building are excluded.<br />

insulation, and accessories; all other components of building are<br />

excluded.<br />

5 Length of coverage 10 or 15 years 5 years: any APPEX modified bitumen membrane product installed over one 20 years for new construction or tear-off.<br />

ply of felt or any approved substrate; 10 years: any APPEX modified<br />

bitumen membrane product installed over one ply or base sheet over an<br />

approved substrate; 12 years: any APPEX modified bitumen membrane<br />

product installed over one base ply and an approved substrate.<br />

6 Nature of remedy IDS will, at its option, either repair the membrane or issue a prorated credit JM will take prompt appropriate action <strong>to</strong> return the <strong>Roof</strong>ing System <strong>to</strong> a JM will take prompt appropriate action <strong>to</strong> return the <strong>Roof</strong>ing System <strong>to</strong> a<br />

against the purchase of a new roofing membrane from IDS. The owner's watertight condition. Exclusive responsibility and liability of JM under watertight condition. Exclusive responsibility and liability of JM under<br />

sole remedies and IDS' liabilities and obligations shall be limited <strong>to</strong> the guarantee is <strong>to</strong> make repairs that may be necessary <strong>to</strong> maintain the <strong>Roof</strong>ing guarantee is <strong>to</strong> make repairs that may be necessary <strong>to</strong> maintain the<br />

replacement of defective IDS EPDM vulcanized roofing membrane by repair System in a water tight condition. <strong>Roof</strong>ing System in a water tight condition.<br />

or substitution of new material<br />

7 Monetary limitations IDS' obligation <strong>to</strong> remedy defects shall not exceed the original cost of IDS Guarantee includes space for JM's maximum monetary obligation <strong>to</strong> be Guarantee includes space for JM's maximum monetary obligation <strong>to</strong> be<br />

materials as charged by IDS inserted. (JM indicates that for these specifications, JM's maximum liability inserted. (JM indicates that for these specifications, JM's maximum<br />

is the original installed cost of the roof system.)<br />

liability is the original installed cost of the roof system.)<br />

8 Notification requirements Written notification within 30 days of discovery of any defect in the IDS Written notification <strong>to</strong> JM's Guarantee Services Department, 10100 W. Ute Written notification <strong>to</strong> JM's Guarantee Services Department, 10100 W.<br />

roofing system by certified mail, return receipt requested, <strong>to</strong> IDS at 5110 Ave., Little<strong>to</strong>n, CO 80127, immediately upon discovery of leak and in no Ute Ave., Little<strong>to</strong>n, CO 80127, immediately upon discovery of leak and in<br />

Angola Road, Toledo, OH 43615 event later than 30 days after discovery of leak. no event later than 30 days after discovery of leak.<br />

9 Exclusive or additional<br />

remedy<br />

10 Inclusion of consequential<br />

damages<br />

11 Determination of warranty<br />

applicability<br />

12 Specific exclusions from<br />

coverage (see Item 12 in<br />

Introduction)<br />

The warranty replaces and excludes all other warranties; remedy stated in Guarantee states that JM and its affiliates shall not be liable for any Guarantee states that JM and its affiliates shall not be liable for any<br />

warranty is the sole and exclusive remedy; excludes UCC warranties. damages which are based upon negligence, breach of warranty, strict damages which are based upon negligence, breach of warranty, strict<br />

The warranty states: The building owners sole remedy is <strong>to</strong> file a claim liability, or any other theory of liability other than exclusive liability set forth liability, or any other theory of liability other than exclusive liability set<br />

against our product liability or completed operations for any underlying in guarantee; excludes UCC warranties. forth in guarantee; excludes UCC warranties.<br />

materials or any other damages whatsoever. The products must be proven<br />

defective scientifically by certified labora<strong>to</strong>ries.<br />

No No No<br />

Neutral (no provision). Neutral; JM arranges inspection Neutral; JM arranges inspection<br />

1, 2, 3, 4, 5, 6, 7, 10, 11, 12 (including those items contained in IDS <strong>Roof</strong>ing 1, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 15, 18 1, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 15, 18<br />

Care and Maintenance Guide), 13, 16, 17, 18, 19, 24. (Warranty also<br />

excludes damage or loss caused by pests, insect infestation, ice s<strong>to</strong>rm, or<br />

any winds<strong>to</strong>rm or occurrence covered by fire and winds<strong>to</strong>rm insurance,<br />

including subrogation claims.)<br />

13 Wind coverage/exclusions The warranty excludes winds<strong>to</strong>rms, wind gusts/gales, hurricanes, and JM indicates that guarantee covers roof damage resulting from wind speeds JM indicates that guarantee covers roof damage resulting from wind<br />

<strong>to</strong>rnadoes. IDS indicates that warranty covers wind speeds up <strong>to</strong> Beaufort up <strong>to</strong> 63 mph. speeds up <strong>to</strong> 63 mph.<br />

Scale 8, which starts at 39 mph. The plate bond system is not wind uplift<br />

rated.<br />

14 Specific conditions <strong>to</strong> make<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

C, M, N, S C, F, M (See Special Features/Conditions.) C, F, M (See Special Features/Conditions.)<br />

15 Cost <strong>to</strong> obtain None 5 yrs: $5.00/sq; 10 yrs: $6.00/sq; 12 yrs: $8.50/sq $17.00/square<br />

778


16 Minimum charge None 5 years: $500; 10 years: $600; 12 years: $850 $1,700<br />

17 Ineligible structure or<br />

building use<br />

18 Pre-construction notice and<br />

approval requirements<br />

19 Approved, authorized, or<br />

licensed requirements<br />

The warranty states that IDS shall have no obligation if building is used for Cold-s<strong>to</strong>rage buildings, private residences, s<strong>to</strong>rage silos, heated tanks Cold-s<strong>to</strong>rage buildings, private residences, s<strong>to</strong>rage silos, heated tanks<br />

noncommercial purposes, such as residential, personal, family, or<br />

household purposes<br />

Prior <strong>to</strong> the job commencing, the contrac<strong>to</strong>r submits an application <strong>to</strong> install Contrac<strong>to</strong>r is required <strong>to</strong> submit a guarantee application for approval 14 Contrac<strong>to</strong>r is required <strong>to</strong> submit a guarantee application for approval 14<br />

IDS roofing systems. Upon completion, the contrac<strong>to</strong>r submits notice of days prior <strong>to</strong> start of construction. days prior <strong>to</strong> start of construction.<br />

completion and request for warranty.<br />

Yes Yes Yes<br />

20 Job inspection policy IDS field technical department will make on-site inspections prior <strong>to</strong> and Inspections made by local JM field representatives prior, during, and after Inspections made by local JM field representatives prior, during, and after<br />

during application upon request. IDS makes inspection after completion application as well as two years after issuance of guarantee; no charge. application as well as two years after issuance of guarantee; no charge.<br />

prior <strong>to</strong> issuance of warranty, as well as two years after issuance of<br />

warranty; no charge. If a second inspection is required, inspection charge is<br />

$350/day plus $0.26 per mile.<br />

21 Contrac<strong>to</strong>r’s post-installation<br />

obligation<br />

22 Backed by named insurance<br />

or surety<br />

23 Issuing entity manufactures<br />

and/or sells products<br />

24 Conditions for renewal or<br />

extension<br />

The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for two Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for<br />

two years. years. two years.<br />

No; IDS indicates that it does not carry insurance covering its warranty No; JM indicates that it does not carry insurance covering its warranty No; JM indicates that it does not carry insurance covering its warranty<br />

obligations. obligations. obligations<br />

IDS manufactures and sells the product. JM manufactures and sells product. JM manufactures and sells product.<br />

No renewal provision No renewal provision No renewal provision<br />

25 Assignability The warranty is not transferable Guarantee will be transferred by JM, in its sole discretion, only after Guarantee will be transferred by JM, in its sole discretion, only after<br />

receiving satisfac<strong>to</strong>ry information and payment of a transfer fee, which must receiving satisfac<strong>to</strong>ry information and payment of a transfer fee, which<br />

be delivered <strong>to</strong> JM as soon as practical, but no later than 30 days after the must be delivered <strong>to</strong> JM as soon as practical, but no later than 30 days<br />

date of building ownership transfer.<br />

after the date of building ownership transfer.<br />

26 Special features/condition The warranty states: IDS is under no obligation <strong>to</strong> issue a warranty on any In order <strong>to</strong> continue guarantee coverage, owner must implement a To be eligible for this 20 year guarantee, a four-ply specification with<br />

job until an affidavit is signed by the building owner and the roofing maintenance program prescribed by JM on the reverse side of guarantee, GlasPly minimum Premier Felts must be installed over two layers of JM<br />

contrac<strong>to</strong>r stating that the job was done with IDS material, specifications, including: (a) maintaining a file showing all inspections and repairs; (b) insulation with the <strong>to</strong>p layer being JM Fesco Board. In order <strong>to</strong> continue<br />

and details. IDS warranty is clearly limited <strong>to</strong> the repair of IDS material if inspecting roof at least semiannually; © removing any debris; (d) cleaning guarantee coverage, owner must implement a maintenance program<br />

defective and the repair of the workmanship if it is made defective by the gutters, downspouts, drains, and surrounding areas; (e) repairing any prescribed by JM on the reverse side of guarantee, including: (a)<br />

defective material. Thus, the warranty is ambiguous as <strong>to</strong> whether it covers damaged, loose or poorly sealed materials by an approved contrac<strong>to</strong>r; (f) maintaining a file showing all inspections and repairs; (b) inspecting roof<br />

both material and workmanship of contrac<strong>to</strong>r. repairing damaged masonry, poorly mounted counterflashing, loose at least semi-annually; © removing any debris; (d) cleaning gutters,<br />

All legal actions against IDS must be noticed and venued in Toledo, Lucas caulking, bad mortar joints, and any loose s<strong>to</strong>ne or tile coping that abut the downspouts, drains, and surrounding areas; (e) repairing any damaged,<br />

County, Ohio and Ohio law shall apply. roof; (g) correcting materials at edges of the roof that have been lifted by loose or poorly sealed materials by an approved contrac<strong>to</strong>r; (f) repairing<br />

The warranty states: The building owners sole remedies on the above wind by an approved contrac<strong>to</strong>r; (h) examining roof <strong>to</strong>p equipment <strong>to</strong> damaged masonry, poorly mounted counterflashing, loose caulking, bad<br />

conditions and limitation of recovery on any and all claims will be filed determine if they move excessively or leak; (I) checking building exterior for mortar joints, and any loose s<strong>to</strong>ne or tile coping that abut the roof; (g)<br />

against IDS insurance carrier. Any dispute which cannot be settled within settlement or movement; and (j) recoating any cracked, flaking, or blistered correcting materials at edges of the roof that have been lifted by wind by<br />

the terms and conditions of this warranty limits the building owners recovery areas of protective coatings. an approved contrac<strong>to</strong>r; (h) examining roof <strong>to</strong>p equipment <strong>to</strong> determine if<br />

<strong>to</strong> the realms of our insurance policy and/or our suppliers, and/or his agents. In the event of an emergency condition that requires they move excessively or leak; (I) checking building exterior for<br />

If the courts find the warranty legally binding or non-binding between IDS immediate repair <strong>to</strong> avoid substantial damage <strong>to</strong> building or its contents, JM settlement or movement; and (j) recoating any cracked, flaking, or<br />

and the owner, then the UCC statute of limitations applies in lieu of the will reimburse the owner for repair expenses for essential temporary repairs blistered areas of protective coatings.<br />

warranty in its entirety. that would have In the event of an emergency condition that requires immediate repair<br />

The warranty states: All parties must except [sic] industry standards, state of been JM's responsibility. <strong>to</strong> avoid substantial damage <strong>to</strong> building or its contents, JM will reimburse<br />

the art technology, FM (Fac<strong>to</strong>ry Mutual), UL (Underwriters Labora<strong>to</strong>ries), In the event JM pays for repairs, which are required due <strong>to</strong> acts or the owner for repair expenses for essential temporary repairs that would<br />

and ASTM testing (as published by them) as the standard that is excepted omissions of others, JM shall be subrogated <strong>to</strong> all rights of recovery of the have been JM's responsibility.<br />

[sic] by the industry and all parties with no deviations as tested by IDS. building owner <strong>to</strong> the extent of the amount of the repairs. No one is In the event JM pays for repairs, which are required due <strong>to</strong> acts or<br />

The official weather report is the nearest airport or the national weather authorized <strong>to</strong> change, alter, or modify the provisions of the guarantee other omissions of others, JM shall be subrogated <strong>to</strong> all rights of recovery of<br />

bureau. If there are damaging winds recorded at the airport and wind than the Manager, Marketing and Technical Services or authorized the building owner <strong>to</strong> the extent of the amount of the repairs. No one is<br />

damage is found on the building, the owner's insurance will be responsible delegate. All terms and conditions are <strong>to</strong> be construed under internal laws authorized <strong>to</strong> change, alter, or modify the provisions of the guarantee<br />

for the repair of the roofing system. If the owner's insurance denies of Colorado. other than the Manager, Marketing and Technical Services or authorized<br />

coverage for the wind damage, the owner will hold IDS harmless, along with<br />

delegate.<br />

the other terms, conditions, and limitations of warranty. Note: Ground Parties agree that any controversy or claims relating <strong>to</strong> Guarantee shall<br />

speed winds must be calculated and multiplied by three in order <strong>to</strong><br />

be settled exclusively by arbitration in accordance with the Construction<br />

determine the effect the wind has on a system.<br />

Industry Arbitration Rules of the American Arbitration <strong>Association</strong> at the<br />

If a defect is not caused by workmanship, IDS will advise of the type and/or<br />

Denver, Colorado office. All terms and conditions are <strong>to</strong> be construed<br />

extent of repairs required <strong>to</strong> be made at owner's expense by a qualified<br />

under internal law of Colorado.<br />

applica<strong>to</strong>r; all investigation and repair costs are the owner's responsibility Because JM does not practice engineering or architecture, neither the<br />

issuance of the guarantee nor any review of buildings construction or<br />

inspection of roof plans by JM representatives shall constitute any<br />

warranty by JM or in any way constitute an extension of the terms and<br />

conditions of the Guarantee<br />

27 Executed by owner No Yes; Guarantee must be signed, dated, and returned <strong>to</strong> JM at its office in<br />

Little<strong>to</strong>n, CO.<br />

779


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Johns Manville International, Inc. (JM) Johns Manville International, Inc. (JM) Johns Manville International, Inc. (JM)<br />

2 Title, original publication "Gold Shield <strong>Roof</strong>ing System Guarantee"; June 1997; JM-645-2 "Gold Shield <strong>Roof</strong>ing System Guarantee;" September 1997; JM- "Gold Shield <strong>Roof</strong>ing System Guarantee"; September 1997; JMdate,<br />

and identifying symbol, (6/97), RS-7082 11-97 645-2 (9/97), RS-7082 11-97 645-2 (9/97), RS-7002 11-97<br />

if any<br />

3 Product, specification, or BUR Specifications: 4GIS, 3GIS, 4GIG, 3GIG, 4GNS, 3GNS, BUR Specifications: 4GIS, 4GIG, 5GNG, 5GLG, 5GIC,with APP Modified Bitumen Products: Bicor or Tricor when installed<br />

system covered 4GNG, 3GNG, 4GLG, 3GLG, 4GIC, 4GNC, 3GIC, 3GNC, 4GIG- GlasPly Premier Felts, installed over two layers of Fescoboard over two APPEX base sheets, utilizing three plies of material.<br />

CT, 4GNG-CT, 3GIG-CT, 3GNG-CT. Modified Bitumen<br />

Specifications: 2GID, 2GND, 2CID, 2CND, 3CID, 3CND, 3CIG,<br />

3CNG, 2PIN-W, 2PIS-W, 2PFN-W, 3PIN-W<br />

4 Scope of coverage Material and workmanship; JM guarantees that it will pay for the Material and workmanship; JM guarantees that it will pay for the Material and workmanship; JM guarantees that it will pay for the<br />

materials and labor required <strong>to</strong> promptly repair the roofing system materials and labor required <strong>to</strong> promptly repair the roofing system materials and labor required <strong>to</strong> promptly repair the roofing<br />

<strong>to</strong> return it <strong>to</strong> a watertight condition if leaks occur due <strong>to</strong> ordinary <strong>to</strong> return it <strong>to</strong> a watertight condition if leaks occur due <strong>to</strong> ordinary system <strong>to</strong> return it <strong>to</strong> a watertight condition if leaks occur due <strong>to</strong><br />

wear and tear or deficiencies in any or all of the component wear and tear or deficiencies in any or all of the component ordinary wear and tear or deficiencies in any or all of the<br />

materials of the <strong>Roof</strong>ing System or workmanship deficiencies in materials of the <strong>Roof</strong>ing System or workmanship deficiencies in component materials of the <strong>Roof</strong>ing System or workmanship<br />

the application of the <strong>Roof</strong>ing System. <strong>Roof</strong>ing System the application of the <strong>Roof</strong>ing System. <strong>Roof</strong>ing System deficiencies in the application of the <strong>Roof</strong>ing System. <strong>Roof</strong>ing<br />

components are JM membrane, flashing, insulation, and components are JM membrane, flashing, insulation, and System components are JM membrane, flashing, insulation, and<br />

accessories; all other components of building are excluded. accessories; all other components of building are excluded. accessories; all other components of building are excluded<br />

5 Length of coverage 5 or 10 years 20 years for new construction or tear-off 20 years<br />

6 Nature of remedy JM will take prompt appropriate action <strong>to</strong> return the <strong>Roof</strong>ing JM will take prompt appropriate action <strong>to</strong> return the <strong>Roof</strong>ing JM will take prompt appropriate action <strong>to</strong> return the <strong>Roof</strong>ing<br />

System <strong>to</strong> a watertight condition. Exclusive responsibility and System <strong>to</strong> a watertight condition. Exclusive responsibility and System <strong>to</strong> a watertight condition. Exclusive responsibility and<br />

liability of JM under guarantee is <strong>to</strong> make repairs that may be liability of JM under guarantee is <strong>to</strong> make repairs that may be liability of JM under guarantee is <strong>to</strong> make repairs that may be<br />

necessary <strong>to</strong> maintain the <strong>Roof</strong>ing System in a water tight necessary <strong>to</strong> maintain the <strong>Roof</strong>ing System in a water tight necessary <strong>to</strong> maintain the <strong>Roof</strong>ing System in a water tight<br />

condition. condition. condition.<br />

7 Monetary limitations Guarantee includes space for JM's maximum monetary obligation <strong>to</strong> be Guarantee includes space for JM's maximum monetary obligation Guarantee includes space for JM's maximum monetary<br />

inserted. (JM indicates that for these specifications, JM's maximum liability <strong>to</strong> be inserted. (JM indicates that for these specifications, JM's obligation <strong>to</strong> be inserted. (JM indicates that for these<br />

is the original installed cost of the roof system.) maximum liability is$100 per sq.; minimum coverage is $10,000.) specifications, JM's maximum liability is the original installed<br />

cost of the roof system.)<br />

8 Notification requirements Written notification <strong>to</strong> JM's Guarantee Services Department, 10100 W. Ute Written notification <strong>to</strong> JM's Guarantee Services Department, Written notification <strong>to</strong> JM's Guarantee Services Department,<br />

Ave., Little<strong>to</strong>n, CO 80127, immediately upon discovery of leak and in no 10100 W. Ute Ave., Little<strong>to</strong>n, CO 80127, immediately upon 10100 W. Ute Ave., Little<strong>to</strong>n, CO 80127, immediately upon<br />

event later than 30 days after discovery of leak. discovery of leak and in no event later than 30 days after discovery discovery of leak and in no event later than 30 days after<br />

of leak.<br />

discovery of leak.<br />

9 Exclusive or additional Guarantee states that JM and its affiliates shall not be liable for Guarantee states that JM and its affiliates shall not be liable for Guarantee states that JM and its affiliates shall not be liable for<br />

remedy any damages which are based upon negligence, breach of any damages which are based upon negligence, breach of any damages which are based upon negligence, breach of<br />

warranty, strict liability, or any other theory of liability other than warranty, strict liability, or any other theory of liability other than warranty, strict liability, or any other theory of liability other than<br />

exclusive liability set forth in guarantee; excludes UCC warranties exclusive liability set forth in guarantee; excludes UCC warranties exclusive liability set forth in guarantee; excludes UCC<br />

warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral; JM arranges inspection Neutral; JM arranges inspection Neutral; JM arranges inspection<br />

applicability<br />

12 Specific exclusions from 1, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 15, 18 1, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 15, 18 1, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 15, 18<br />

coverage (see Item 12 in<br />

Introduction)<br />

13 Wind coverage/exclusions JM indicates that guarantee covers roof damage resulting from JM indicates that guarantee covers roof damage resulting from JM indicates that guarantee covers roof damage resulting from<br />

wind speeds up <strong>to</strong> 63 mph. wind speeds up <strong>to</strong> 63 mph. wind speeds up <strong>to</strong> 63 mph.<br />

14 Specific conditions <strong>to</strong> make C, F, M (See Special Features/Conditions.) C, F, M (See Special Features/Conditions.) C, F, M (See Special Features/Conditions.)<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain 5 years: $5.00/square; 10 years: $6.00/square $12.00/square $17.00/square<br />

16 Minimum charge 5 years: $500; 10 years: $600 $1,200 $1,700<br />

780


17 Ineligible structure or Cold-s<strong>to</strong>rage buildings, private residences, s<strong>to</strong>rage silos, heated Cold-s<strong>to</strong>rage buildings, private residences, s<strong>to</strong>rage silos, heated Cold-s<strong>to</strong>rage buildings, private residences, s<strong>to</strong>rage silos, heated<br />

building use tanks tanks tanks<br />

18 Pre-construction notice and Contrac<strong>to</strong>r is required <strong>to</strong> submit a guarantee application for Contrac<strong>to</strong>r is required <strong>to</strong> submit a guarantee application for Contrac<strong>to</strong>r is required <strong>to</strong> submit a guarantee application for<br />

approval requirements approval 14 days prior <strong>to</strong> start of construction. approval 14 days prior <strong>to</strong> start of construction. approval 14 days prior <strong>to</strong> start of construction.<br />

19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy Inspections made by local JM field representatives prior, during, Inspections made by local JM field representatives prior, during, Inspections made by local JM field representatives prior, during,<br />

and after application as well as two years after issuance of and after application as well as two years after issuance of and after application as well as two years after issuance of<br />

guarantee; no charge. guarantee; no charge. guarantee; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

obligation deficiencies for two years. deficiencies for two years. deficiencies for two years.<br />

22 Backed by named insurance No; JM indicates that it does not carry insurance covering its No; JM indicates that it does not carry insurance covering its No; JM indicates that it does not carry insurance covering its<br />

or surety warranty obligations warranty obligations warranty obligations.<br />

23 Issuing entity manufactures JM manufactures and sells product. JM manufactures and sells product. JM manufactures and sells product.<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability Guarantee will be transferred by JM, in its sole discretion, only after Guarantee will be transferred by JM, in its sole discretion, only Guarantee will be transferred by JM, in its sole discretion, only<br />

receiving satisfac<strong>to</strong>ry information and payment of a transfer fee, which must after receiving satisfac<strong>to</strong>ry information and payment of a transfer after receiving satisfac<strong>to</strong>ry information and payment of a transfer<br />

be delivered <strong>to</strong> JM as soon as practical, but no later than 30 days after the<br />

fee, which must be delivered <strong>to</strong> JM as soon as practical, but no fee, which must be delivered <strong>to</strong> JM as soon as practical, but no<br />

date of building ownership transfer<br />

later than 30 days after the date of building ownership transfer later than 30 days after the date of building ownership transfer.<br />

26 Special features/condition All listed specifications are eligible for either the 5- or 10-year guarantee. To be eligible for this 20-year guarantee, a four-ply specification with In order <strong>to</strong> continue guarantee coverage, owner must implement<br />

In order <strong>to</strong> continue guarantee coverage, owner must implement a GlasPly Premier Felts must be installed over two layers of either JM Fesco a maintenance program prescribed by JM on the reverse side of<br />

maintenance program prescribed by JM on the reverse side of guarantee, or insulation; the project must be either new<br />

guarantee, including: (a) maintaining a file showing all<br />

including: (a) maintaining a file showing all inspections and repairs; (b) construction or tear-off.<br />

inspecting roof at least semiannually; © removing any debris; (d) cleaning<br />

inspections and repairs; (b) inspecting roof at least<br />

In order <strong>to</strong> continue guarantee coverage, owner must<br />

gutters, downspouts, drains, and surrounding areas; (e) repairing any<br />

semiannually; © removing any debris; (d) cleaning gutters,<br />

implement a maintenance program prescribed by JM on the<br />

damaged, loose, or poorly sealed metal flashing and valleys by an approved<br />

downspouts, drains, and surrounding areas; (e) repairing any<br />

contrac<strong>to</strong>r; (f) repairing damaged masonry, poorly mounted counter-flashing,<br />

reverse side of the guarantee, including (a) maintaining a file<br />

damaged, loose or poorly sealed materials by an approved<br />

loose caulking, bad mortar joints, and any loose s<strong>to</strong>ne or tile coping that showing all inspections and repairs; (b) inspecting roof at least<br />

contrac<strong>to</strong>r; (f) repairing damaged masonry, poorly mounted<br />

abut the roof; (g) correcting materials at edges of the roof that have been semiannually; (c) removing any debris; (d) cleaning gutters,<br />

counterflashing, loose caulking, bad mortar joints, and any loose<br />

lifted by wind by an approved contrac<strong>to</strong>r; (h) examining roof <strong>to</strong>p equipment downspouts, drains, and surrounding areas; (e) repairing any<br />

s<strong>to</strong>ne or tile coping that abut the roof; (g) correcting materials at<br />

<strong>to</strong> determine if they move excessively or leak; (I) checking building exterior damaged, loose, or poorly sealed metal flashing and valleys by an<br />

for settlement or movement; and (j) recoating any cracked, flaking, or<br />

edges of the roof that have been lifted by wind by an approved<br />

approved contrac<strong>to</strong>r; (f) repairing damaged masonry, poorly<br />

blistered areas of protective coatings.<br />

contrac<strong>to</strong>r; (h) examining roof <strong>to</strong>p equipment <strong>to</strong> determine if they<br />

mounted counter-flashing, loose caulking, bad mortar joints, and<br />

In the event of an emergency condition that requires immediate repair <strong>to</strong><br />

move excessively or leak; (I) checking building exterior for<br />

avoid substantial damage <strong>to</strong> building or its contents, JM will reimburse the any loose s<strong>to</strong>ne or tile coping that abut the roof; (g) correcting<br />

settlement or movement; and (j) recoating any cracked, flaking,<br />

owner for repair expenses for essential temporary repairs that would have materials at edges of the roof that have been lifted by wind by an<br />

or blistered areas of protective coatings.<br />

been JM's responsibility.<br />

approved contrac<strong>to</strong>r; (h) examining roof <strong>to</strong>p equipment <strong>to</strong><br />

In the event of an emergency condition that requires immediate<br />

In the event JM pays for repairs, which are required due <strong>to</strong> acts or determine if they move excessively or leak; (i) checking building<br />

repair <strong>to</strong> avoid substantial damage <strong>to</strong> building or its contents,<br />

omissions of others, JM shall be subrogated <strong>to</strong> all rights of recovery of the exterior for settlement or movement; and (j) recoating any cracked,<br />

building owner <strong>to</strong> the extent of the amount of the repairs. No one is<br />

JM will reimburse the owner for repair expenses for essential<br />

flaking, or blistered areas of protective coatings.<br />

authorized <strong>to</strong> change, alter, or modify the provisions of the guarantee other<br />

temporary repairs that would have been JM's responsibility.<br />

In the event of an emergency condition that requires immediate<br />

than the Manager, Marketing and Technical Services or authorized<br />

In the event JM pays for repairs, which are required due <strong>to</strong> acts<br />

delegate.<br />

repair <strong>to</strong> avoid substantial damage <strong>to</strong> building or its contents, JM<br />

or omissions of others, JM shall be subrogated <strong>to</strong> all rights of<br />

Parties agree that any controversy or claims relating <strong>to</strong> Guarantee shall be will reimburse the owner for repair expenses for essential<br />

recovery of the building owner <strong>to</strong> the extent of the amount of the<br />

settled exclusively by arbitration in accordance with the Construction temporary repairs that would have been JM's responsibility.<br />

repairs. No one is authorized <strong>to</strong> change, alter, or modify the<br />

Industry Arbitration Rules of the American Arbitration <strong>Association</strong> at the In the event JM pays for repairs that are required due <strong>to</strong> acts or<br />

Denver, Colorado office. All terms and conditions are <strong>to</strong> be construed under<br />

provisions of the guarantee other than the Manager, Marketing<br />

omissions of others, JM shall be subrogated <strong>to</strong> all rights of<br />

internal law of Colorado.<br />

and Technical Services or authorized delegate. All terms and<br />

recovery of the building owner <strong>to</strong> the extent of the amount of the<br />

Because JM does not practice engineering or architecture, neither the<br />

conditions are <strong>to</strong> be construed under internal laws of Colorado.<br />

issuance of the guarantee nor any review of buildings construction or repairs. No one is authorized <strong>to</strong> change, alter, or modify the<br />

inspection of roof plans by JM representatives shall constitute any warranty provisions of the guarantee other than the Manager, Marketing<br />

by JM or in any way constitute an extension of the terms and conditions of<br />

the Guarantee<br />

and Technical Services or authorized delegate. All terms and<br />

conditions are <strong>to</strong> be construed under internal law of Colorado.<br />

27 Executed by owner Yes; Guarantee must be signed, dated, and returned <strong>to</strong> JM at its office in Yes; Guarantee must be signed, dated, and returned <strong>to</strong> JM at its office in<br />

Little<strong>to</strong>n, CO.<br />

Little<strong>to</strong>n, CO.<br />

No<br />

781


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Johns Manville International, Inc. (JM) Johns Manville International, Inc. (JM) Johns Manville International, Inc. (JM)<br />

2 Title, original publication date, "Gold Shield <strong>Roof</strong>ing System Guarantee"; September 1997; JM-645-2 (9/97) "Gold Shield <strong>Roof</strong>ing System Guarantee"; September 1997; JM-645-2 (9/97) “UltraGard <strong>Roof</strong>ing System Guarantee;” April 1998; RS-8048 (4/98)<br />

and identifying symbol, if any RS-7082 11/97 RS-7082 11-97<br />

3 Product, specification, or BUR Specifications: 4GIS, 4GIG, 3GIS, 3GIG, 4GIC, 4GNC, 4GNS, with use BUR Specifications: 4GIS, 4GIG, 5GIC, 5GNS, 5GNG, with use of GlasPly EPDM: Ballasted, Mechanically Attached, Fully Adhered<br />

system covered of GlasPly Premier Felts; DynaKap Modified Bitumen Specifications: 2CID, Premier Felts and one layer of Fescoboard; DynaKap Modified Bitumen PVC: Mechanically Attached, Fully Adhered<br />

2CIG, 2CND, 2CNG, 3CID, 3CND (See Special Features/Conditions) Specifications: 3CID, 3CIG, 3CND, 3CNG (See Special<br />

Features/Conditions).<br />

4 Scope of coverage Material and workmanship; JM guarantees that it will pay for the materials Material and workmanship; JM guarantees that it will pay for the materials Material and workmanship; JM guarantees that it will pay for the materials<br />

and labor required <strong>to</strong> promptly repair the roofing system <strong>to</strong> return it <strong>to</strong> a and labor required <strong>to</strong> promptly repair the roofing system <strong>to</strong> return it <strong>to</strong> a and labor required <strong>to</strong> promptly repair the roofing system <strong>to</strong> return it <strong>to</strong> a<br />

watertight condition if leaks occur due <strong>to</strong> ordinary wear and tear or watertight condition if leaks occur due <strong>to</strong> ordinary wear and tear or watertight condition if leaks occur due <strong>to</strong> ordinary wear and tear or<br />

deficiencies in any or all of the component materials of the <strong>Roof</strong>ing System deficiencies in any or all of the component materials of the <strong>Roof</strong>ing System deficiencies in any or all of the component materials of the <strong>Roof</strong>ing<br />

or workmanship deficiencies in the application of the <strong>Roof</strong>ing System. or workmanship deficiencies in the application of the <strong>Roof</strong>ing System. System or workmanship deficiencies in the application of the <strong>Roof</strong>ing<br />

<strong>Roof</strong>ing System components are JM membrane, flashing, insulation, and <strong>Roof</strong>ing System components are JM membrane, flashing, insulation, and System. <strong>Roof</strong>ing System components are JM membrane, flashing,<br />

accessories; all other components of building are excluded. accessories; all other components of building are excluded. insulation, and accessories; all other components of building are<br />

excluded<br />

5 Length of coverage 5 years for re-roofing; 10 years for new construction or tear-off. 15 years for new construction or tear-off 5, 10 or 15 years<br />

6 Nature of remedy JM will take prompt appropriate action <strong>to</strong> return the <strong>Roof</strong>ing System <strong>to</strong> a JM will take prompt appropriate action <strong>to</strong> return the <strong>Roof</strong>ing System <strong>to</strong> a JM will take prompt appropriate action <strong>to</strong> return the <strong>Roof</strong>ing System <strong>to</strong> a<br />

watertight condition. Exclusive responsibility and liability of JM under watertight condition. Exclusive responsibility and liability of JM under watertight condition. Exclusive responsibility and liability of JM under<br />

guarantee is <strong>to</strong> make repairs that may be necessary <strong>to</strong> maintain the <strong>Roof</strong>ing guarantee is <strong>to</strong> make repairs that may be necessary <strong>to</strong> maintain the <strong>Roof</strong>ing guarantee is <strong>to</strong> make repairs that may be necessary <strong>to</strong> maintain the<br />

System in a water tight condition. System in a water tight condition. <strong>Roof</strong>ing System in a water tight condition<br />

7 Monetary limitations Guarantee includes space for JM's maximum monetary obligation <strong>to</strong> be Guarantee includes space for JM's maximum monetary obligation <strong>to</strong> be Guarantee includes space for JM's maximum monetary obligation <strong>to</strong> be<br />

inserted. (JM indicates that for these specifications, JM's maximum liability inserted. (JM indicates that for these specifications, JM's maximum liability inserted. (JM indicates that for these specifications, JM's maximum<br />

is the original installed cost of the roof system.) is the original installed cost of the roof system.) liability is the original installed cost of the roof system.)<br />

8 Notification requirements Written notification <strong>to</strong> JM's Guarantee Services Department, 10100 W. Ute Written notification <strong>to</strong> JM's Guarantee Services Department, 10100 W. Ute Written notification <strong>to</strong> JM's Guarantee Services Department, 10100 W.<br />

A e., Little<strong>to</strong>n, CO 80127 immediately upon discovery of leak and in no Ave., Little<strong>to</strong>n, CO 80127, immediately upon discovery of leak and in no Ute Ave., Little<strong>to</strong>n, CO 80127, immediately upon discovery of leak and<br />

event later than 30 days after discovery of leak. event later than 30 days after discovery of leak. in no event later than 30 days after discovery of leak.<br />

9 Exclusive or additional Guarantee states that JM and its affiliates shall not be liable for any Guarantee states that JM and its affiliates shall not be liable for any Guarantee states that JM and its affiliates shall not be liable for any<br />

remedy damages which are based upon negligence, breach of warranty, strict damages which are based upon negligence, breach of warranty, strict damages which are based upon negligence, breach of warranty, strict<br />

liability, or any other theory of liability other than exclusive liability set forth liability, or any other theory of liability other than exclusive liability set forth liability, or any other theory of liability other than exclusive liability set<br />

in guarantee; excludes UCC warranties. in guarantee; excludes UCC warranties. forth in guarantee; excludes UCC warranties<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral; JM arranges inspection Neutral; JM arranges inspection Neutral; JM arranges inspection<br />

applicability<br />

12 Specific exclusions from 1, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 15, 18 1, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 15, 18 1, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 15, 18<br />

coverage (see Item 12 in<br />

Introduction)<br />

13 Wind coverage/exclusions JM indicates that guarantee covers roof damage resulting from wind speeds JM indicates that guarantee covers roof damage resulting from wind speeds JM indicates that guarantee covers roof damage resulting from wind<br />

up <strong>to</strong> 63 mph. up <strong>to</strong> 63 mph. speeds up <strong>to</strong> 54 mph. Warranty excludes wind speeds in excess of a<br />

strong gale which the Baurfort Scale defines as winds between 47-54<br />

mph.<br />

14 Specific conditions <strong>to</strong> make the C, F, M (See Special Features/Conditions.) C, F, M (See Special Features/Conditions.) C, F, M (See Special Features/Conditions.)<br />

warranty ineffective or null and<br />

void (see Item 14 in Introduction)<br />

15 Cost <strong>to</strong> obtain $8.50/square $12.50/square PVC systems: 5 years $ 4,00/sq;<br />

10 years $ 7.00/sq; 15 years $10.00/sq<br />

16 Minimum charge $850 $1,250 EPDM Systems: 5 years $2.00/sq; 10 years $4.00/sq;<br />

15 years $6.00/sq<br />

When liquid adhesive is used, there is an additional $1.00/square<br />

warranty charge.<br />

17 Ineligible structure or Cold-s<strong>to</strong>rage buildings, private residences, s<strong>to</strong>rage silos, heated tanks Cold-s<strong>to</strong>rage buildings, private residences, s<strong>to</strong>rage silos, heated tanks Cold-s<strong>to</strong>rage buildings, private residences, s<strong>to</strong>rage silos, heated tanks<br />

building use<br />

18 Pre-construction notice and Contrac<strong>to</strong>r is required <strong>to</strong> submit a guarantee application for approval 14 Contrac<strong>to</strong>r is required <strong>to</strong> submit a guarantee application for approval 14 Contrac<strong>to</strong>r is required <strong>to</strong> submit a guarantee application for approval 14<br />

approval requirements days prior <strong>to</strong> start of construction. days prior <strong>to</strong> start of construction. days prior <strong>to</strong> start of construction.<br />

782


19 Approved, authorized, or<br />

licensed requirements<br />

Yes Yes Yes<br />

20 Job inspection policy Inspections made by local JM field representatives prior, during, and after Inspections made by local JM field representatives prior, during, and after Inspections made by local JM field representatives prior, during, and after<br />

application as well as two years after issuance of guarantee; no charge. application as well as two years after issuance of guarantee; no charge. application as well as two years after issuance of guarantee; no charge<br />

21 Contrac<strong>to</strong>r’s post-installation<br />

obligation<br />

22 Backed by named insurance<br />

or surety<br />

23 Issuing entity manufactures<br />

and/or sells products<br />

24 Conditions for renewal or<br />

extension<br />

Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for two Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for two Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies for<br />

years. years. two years.<br />

No; JM indicates that it does not carry insurance covering its warranty No; JM indicates that it does not carry insurance covering its warranty No; JM indicates that it does not carry insurance covering its warranty<br />

obligations obligations. obligations.<br />

JM manufactures and sells product. JM manufactures and sells product. JM manufactures and sells product.<br />

No renewal provision No renewal provision No renewal provision<br />

25 Assignability Guarantee will be transferred by JM, in its sole discretion, only after Guarantee will be transferred by JM, in its sole discretion, only after Guarantee will be transferred by JM, in its sole discretion, only after<br />

receiving satisfac<strong>to</strong>ry information and payment of a transfer fee, which must receiving satisfac<strong>to</strong>ry information and payment of a transfer fee, which must receiving satisfac<strong>to</strong>ry information and payment of a transfer fee, which<br />

be delivered <strong>to</strong> JM as soon as practical, but no later than 30 days after the be delivered <strong>to</strong> JM as soon as practical, but no later than 30 days after the must be delivered <strong>to</strong> JM as soon as practical, but no later than 30 days<br />

date of building ownership transfer. date of building ownership transfer. after the date of building ownership transfer.<br />

26 Special features/condition Specifications 4GIC, 4GNC, 4GNS and RGNG are eligible for this Specifications 5GIC, 5GNC, 5GNS and 5GNG are eligible for this guarantee In order <strong>to</strong> continue guarantee coverage, owner must implement a<br />

guarantee in JM’s designated Region 3 only. in JM's designated Region 3 only. maintenance program prescribed by JM on the reverse side of guarantee,<br />

In order <strong>to</strong> continue guarantee coverage, owner must implement a JM's 15-year guarantee is limited <strong>to</strong> four-ply specifications installed over including: (a) maintaining a file showing all inspections and repairs; (b)<br />

maintenance program prescribed by JM on the reverse side of the one layer of FesCore, used in new construction or tear-off projects. inspecting roof at least semiannually; (c) removing any debris; (d)<br />

guarantee, including (a) maintaining a file showing all inspections and In order <strong>to</strong> continue guarantee coverage, owner must implement a cleaning gutters, downspouts, drains, and surrounding areas; (e)<br />

repairs; (b) inspecting roof at least semiannually; © removing any debris; (d) maintenance program prescribed by JM on the reverse side of guarantee, repairing any damaged, loose or poorly sealed materials by an approved<br />

cleaning gutters, downspouts, drains, and surrounding areas; (e) repairing including: (a) maintaining a file showing all inspections and repairs; (b) contrac<strong>to</strong>r; (f) repairing damaged masonry, poorly mounted<br />

any damaged, loose, or poorly sealed metal flashing and valleys by an inspecting roof at least semiannually; © removing any debris; (d) cleaning counterflashing, loose caulking, bad mortar joints, and any loose s<strong>to</strong>ne or<br />

approved contrac<strong>to</strong>r; (f) repairing damaged masonry, poorly mounted gutters, downspouts, drains, and surrounding areas; (e) repairing any tile coping that abut the roof; (g) correcting materials at edges of the roof<br />

counter-flashing, loose caulking, bad mortar joints, and any loose s<strong>to</strong>ne or damaged, loose or poorly sealed materials by an approved contrac<strong>to</strong>r; (f) that have been lifted by wind by an approved contrac<strong>to</strong>r; (h) examining<br />

tile coping that abut the roof; (g) correcting materials at edges of the roof repairing damaged masonry, poorly mounted counterflashing, loose roof <strong>to</strong>p equipment <strong>to</strong> determine if they move excessively or leak; (i)<br />

that have been lifted by wind by an approved contrac<strong>to</strong>r; (h) examining roof caulking, bad mortar joints, and any loose s<strong>to</strong>ne or tile coping that abut the checking building exterior for settlement or movement; and (j) recoating<br />

<strong>to</strong>p equipment <strong>to</strong> determine if they move excessively or leak; (I) checking roof; (g) correcting materials at edges of the roof that have been lifted by any cracked, flaking, or blistered areas of protective coatings.<br />

building exterior for settlement or movement; and (j) recoating any cracked, wind by an approved contrac<strong>to</strong>r; (h) examining roof <strong>to</strong>p equipment <strong>to</strong> In the event of an emergency condition that requires immediate repair <strong>to</strong><br />

flaking, or blistered areas of protective coatings. determine if they move excessively or leak; (I) checking building exterior for avoid substantial damage <strong>to</strong> building or its contents, JM will reimburse<br />

In the event of an emergency condition that requires immediate repair <strong>to</strong> settlement or movement; and (j) recoating any cracked, flaking, or blistered the owner for repair expenses for essential temporary repairs that would<br />

avoid substantial damage <strong>to</strong> building or its contents, JM will reimburse the areas of protective coatings. have been JM's responsibility.<br />

owner for repair expenses for essential temporary repairs that would have In the event of an emergency condition that requires immediate repair <strong>to</strong> In the event JM pays for repairs, which are required due <strong>to</strong> acts or<br />

been JM's responsibility. avoid substantial damage <strong>to</strong> building or its contents, JM will reimburse the omissions of others, JM shall be subrogated <strong>to</strong> all rights of recovery of<br />

In the event JM pays for repairs that are required due <strong>to</strong> acts or omissions of owner for repair expenses for essential temporary repairs that would have the building owner <strong>to</strong> the extent of the amount of the repairs. No one is<br />

others, JM shall be subrogated <strong>to</strong> all rights of recovery of the building owner been JM's responsibility. authorized <strong>to</strong> change, alter, or modify the provisions of the guarantee<br />

<strong>to</strong> the extent of the amount of the repairs. No one is authorized <strong>to</strong> change, In the event JM pays for repairs, which are required due <strong>to</strong> acts or other than the Manager, Marketing and Technical Services or authorized<br />

alter, or modify the provisions of the guarantee other than the Manager, omissions of others, JM shall be subrogated <strong>to</strong> all rights of recovery of the delegate.<br />

Marketing and Technical Services or authorized delegate. building owner <strong>to</strong> the extent of the amount of the repairs. No one is Parties agree that any controversy or claims relating <strong>to</strong> the Guarantee<br />

Parties agree that any controversy or claims relating <strong>to</strong> Guarantee shall be authorized <strong>to</strong> change, alter, or modify the provisions of the guarantee other shall be settled exclusively by arbitration in accordance with the<br />

settled exclusively by arbitration in accordance with the construction than the Manager, Marketing and Technical Services or authorized Construction Industry Arbitration Rules of the American Arbitration<br />

Industry Arbitration Rules of the American Arbitration <strong>Association</strong> at the delegate. All terms and conditions are <strong>to</strong> be construed under internal laws <strong>Association</strong> at the Denver, Colorado office. All terms and conditions are<br />

Denver, Colorado office. All terms and conditions are <strong>to</strong> be construed under of Colorado. <strong>to</strong> be construed under interal laws of Colorado.<br />

internal law of Colorado. Because JM does not practice engineering or architecture, neither the<br />

Because JM does not practice engineering or architecture, neither the<br />

issuance of the guarantee nor any review of buildings construction or<br />

issuance of the guarantee nor any review of buildings construction or<br />

inspection of roof plans by JM representatives shall constitute any<br />

inspection of roof plans by JM representatives shall constitute any warranty<br />

warranty by JM or in any way constitute an extension of the terms and<br />

by JM or in any way constitute an extension of the terms and conditions of<br />

conditions of the Guarantee.<br />

the Guarantee<br />

27 Executed by owner Yes; Guarantee must be signed, dated, and returned <strong>to</strong> JM at its office in No Yes; Guarantee must be signed, dated, and returned <strong>to</strong> JM at its office in<br />

Little<strong>to</strong>n, CO.<br />

Little<strong>to</strong>n, CO.<br />

783


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity JPS Elas<strong>to</strong>merics Corp. JPS Elas<strong>to</strong>merics Corp. JPS Elas<strong>to</strong>merics Corp.<br />

2 Title, original publication “Hi-Tuff Plus Total Systems Limited Warranty for Commercial Limited Material Warranty for Commercial Building; January 1995, Limited Warranty for Commercial Building - NDL; January,<br />

date, and identifying symbol, Building - NDL”; January, 1995; RSD-FM-13A RSD-FM-12 1995, RSD-FM-11<br />

if any<br />

3 Product, specification, or system Hi-Tuff <strong>Roof</strong>ing System Total <strong>Roof</strong> System includes membrane, Hi-Tuff <strong>Roof</strong>ing membrane wearing surface Hi-Tuff <strong>Roof</strong>ing System<br />

covered<br />

Hi-Tuff edge metal system, insulation, adhesives, fasteners,<br />

insulation plates, term bars, and other materials provided by JPS.<br />

4 Scope of coverage Material and workmanship; JPS warrants <strong>to</strong> repair leaks in the Hi- Material only; JPS warrants that the Hi-Tuff roofing membrane Material and workmanship; JPS warrants <strong>to</strong> repair leaks in the<br />

Tuff roofing system caused by material or workmanship of the JPS wearing surface will withstand the effects of the weather due <strong>to</strong> Hi-Tuff roofing system caused by defects in JPS roofing material<br />

authorized roofing applica<strong>to</strong>r. JPS does not warrant the thermal normal wear and tear of the elements when installed and used in or workmanship of the JPS authorized roofing applica<strong>to</strong>r.<br />

resistance of roof insulation. strict compliance with JPS specifications. Warranty does not Warranty does not include insulation.<br />

include the cost of installation of replacement material or removal<br />

of defective material.<br />

5 Length of coverage 10 or 15 years 5 or 10 years 10 years<br />

6 Nature of remedy JPS will repair leaks in the roofing system using methods If the wearing surface fails due <strong>to</strong> the effects of weather and JPS will repair leaks in the roofing system using methods<br />

determined <strong>to</strong> be suitable at JPS's discretion. normal wear and tear of the elements and the material is installed determined <strong>to</strong> be suitable at JPS' discretion.<br />

and used in strict accordance with JPS specifications, JPS will be<br />

liable for the cost of the material at the time of claim, prorated for<br />

service <strong>to</strong> date of claim. JPS will furnish the owner Hi-Tuff roofing<br />

membrane <strong>to</strong> replace the affected area.<br />

7 Monetary limitations None stated. JPS' liability limited <strong>to</strong> the cost of the material at the time of claim, None stated.<br />

prorated for service <strong>to</strong> date of claim.<br />

8 Notification requirements Written notification of leaks must be delivered <strong>to</strong> JPS Warranty Written notification <strong>to</strong> JPS Warranty Services Department, Written notification of leaks must be delivered <strong>to</strong> JPS Warranty<br />

Service Department at Holyoke, MA 01040-2800, within 30 days of Holyoke, MA 01040-2800, within 30 days of the discovery of any Services Department, Holyoke, MA 01040-2800, within 30 days<br />

discovery. wearing surface failure in the membrane of discovery.<br />

9 Exclusive or additional remedy Warranty and remedies are exclusive and in lieu of any other Warranty and remedies are exclusive and in lieu of any other Warranty and remedies are exclusive and in lieu of any other<br />

remedy or warranty whether written, oral, implied or statu<strong>to</strong>ry; remedy or warranty whether written, oral, implied, or statu<strong>to</strong>ry; remedy or warranty whether written, oral, implied or statu<strong>to</strong>ry;<br />

excludes UCC warranties. excludes UCC warranties. excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty JPS' determination; JPS' sole judgment whether specific JPS' determination; JPS' sole judgment whether specific JPS' determination; JPS' sole judgment whether specific<br />

applicability exclusions and conditions that make warranty null and void occur exclusions and conditions that make warranty null and void occur exclusions and conditions that make warranty null and void<br />

occur<br />

12 Specific exclusions from 1, 3, 5, 7, 17. Warranty states that specific Condition M also 1, 2, 3, 16, 23 1, 3, 5, 7, 17. Warranty states that specific Condition M also<br />

coverage (see Item 12 in makes the warranty inapplicable. makes the warranty inapplicable.<br />

Introduction)<br />

13 Wind coverage/exclusions Warranty excludes winds of peak gust speed of ___ mph Warranty excludes gale-force winds Warranty excludes winds of peak gust speed of ___ mph<br />

measured 10 meters above the ground, hurricanes, and<br />

measured 10 meters above the ground, hurricanes, and<br />

<strong>to</strong>rnadoes.<br />

<strong>to</strong>rnadoes.<br />

14 Specific conditions <strong>to</strong> make the B, C, F, G, H, I B, C, F, G, I B, C, F, G, H, I<br />

warranty ineffective or null and<br />

void (see Item 14 in Introduction)<br />

15 Cost <strong>to</strong> obtain 10 years: $7.00 or $9.00/square; 5 years: $50; 10 years: $100 5 years: $4.00/square<br />

15 years: $10.00 or $12.00/square 10 years: $6.00/square<br />

15 years: $9.00/square<br />

16 Minimum charge 10 years: $375; 15 years: $600 5 years: $50; 10 years: $100 10 years: $450<br />

17 Ineligible structure or Residential buildings Residential buildings Residential buildings<br />

building use<br />

18 Pre-construction notice and Contrac<strong>to</strong>r submits request <strong>to</strong> JPS for approval of warranty form, None Contrac<strong>to</strong>r submits request <strong>to</strong> JPS for approval of warranty<br />

approval requirements along with diagram and details. form, along with diagram and details.<br />

784


19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy JPS technical representative makes on-site inspection after JPS technical representative makes on-site inspection after JPS technical representative makes on-site inspection after<br />

application prior <strong>to</strong> issuance of warranty; no charge. application prior <strong>to</strong> issuance of warranty; no charge. application prior <strong>to</strong> issuance of warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r is normally obligated <strong>to</strong> make repairs <strong>to</strong> all leaks, any Contrac<strong>to</strong>r is normally obligated <strong>to</strong> make repairs <strong>to</strong> all leaks, any Contrac<strong>to</strong>r is normally obligated <strong>to</strong> make repairs <strong>to</strong> all leaks, any<br />

obligation defects, and workmanship deficiencies for two years. defects, and workmanship deficiencies for two years. defects, and workmanship deficiencies for two years.<br />

22 Backed by named insurance No No No<br />

or surety<br />

23 Issuing entity manufactures JPS manufactures and sells the product. JPS manufactures and sells the product. JPS manufactures and sells the product.<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability Warranty is transferable; consult JPS for conditions of Warranty is transferable; consult JPS for conditions of Warranty is transferable; consult JPS for conditions of<br />

transferability. Conditions are noted in JPS maintenance transferability. Conditions are noted in JPS maintenance transferability. Conditions are noted in JPS maintenance<br />

instructions. instructions. instructions.<br />

26 Special features/condition Any controversy or claim arising out of or relating <strong>to</strong> warranty shall Any controversy or claim arising out of or relating <strong>to</strong> warranty shall Any controversy or claim arising out of or relating <strong>to</strong> warranty<br />

be settled by arbitration in accordance with the construction be settled by arbitration in accordance with the construction shall be settled by arbitration in accordance with the<br />

industry rules of the American Arbitration <strong>Association</strong> at the industry rules of the American Arbitration <strong>Association</strong> at the construction industry rules of the American Arbitration<br />

Bos<strong>to</strong>n, Mass. regional office, and judgment upon the award Bos<strong>to</strong>n, Mass. regional office, and judgment upon the award <strong>Association</strong> at the Bos<strong>to</strong>n, Mass. regional office, and judgment<br />

rendered by the arbitra<strong>to</strong>rs may be entered in any court having rendered by the arbitra<strong>to</strong>rs may be entered in any court having upon the award rendered by the arbitra<strong>to</strong>rs may be entered in<br />

jurisdiction thereof. No representative of JPS has authority <strong>to</strong> jurisdiction thereof. No representative of JPS has authority <strong>to</strong> any court having jurisdiction thereof. No representative of JPS<br />

make any representations or promises, except as stated in make any representations or promises, except as stated in has authority <strong>to</strong> make any representations or promises, except<br />

warranty. warranty. as stated in warranty.<br />

27 Executed by owner Yes Yes Yes<br />

785


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity JPS Elas<strong>to</strong>merics Corp. JPS Elas<strong>to</strong>merics Corp. Koppers Industries, Inc.<br />

2 Title, original publication Limited Material Warranty for Commercial Building; January 1995, Limited Warranty for Commercial Building - NDL; January, 1995, Koppers IRMA <strong>Roof</strong> Warranty with Styrofoam Brand Insulation;<br />

date, and identifying symbol, RSD-FM-12 RSD-FM-11 June 1991; CRD-05/91 [Specimen copy has designation<br />

if any<br />

CRD-05/91SP.]<br />

3 Product, specification, or Hi-Tuff <strong>Roof</strong>ing membrane wearing surface Hi-Tuff <strong>Roof</strong>ing System IRMA Built-up <strong>Roof</strong>ing specifications: 263, 264, 273, 274, 463,<br />

system covered 464, 473, 474<br />

4 Scope of coverage Material only; JPS warrants that the Hi-Tuff roofing membrane Material and workmanship; JPS warrants <strong>to</strong> repair leaks in the Hi- Material and workmanship; warranty covers roof water leaks<br />

wearing surface will withstand the effects of the weather due <strong>to</strong> Tuff roofing system caused by defects in JPS roofing material or resulting from ordinary wear and tear of the elements; defects in<br />

normal wear and tear of the elements when installed and used in workmanship of the JPS authorized roofing applica<strong>to</strong>r. Warranty Koppers built-up roofing and flashing or Styrofoam Brand<br />

strict compliance with JPS specifications. Warranty does not does not include insulation. <strong>Roof</strong>ing Material Insulation manufactured by Dow Chemical<br />

include the cost of installation of replacement material or removal<br />

of defective material.<br />

Company; retention of at least 90 percent of Styrofoam Brand<br />

Insulation's published thermal resistance; Styrofoam Brand<br />

Insulation blow-off in roof level wind gusts of up <strong>to</strong> 70 miles per<br />

hour; and workmanship of the original roofing contrac<strong>to</strong>r in<br />

installing Koppers built-up roofing, flashing, and Styrofoam<br />

Brand Insulation.<br />

5 Length of coverage 5 or 10 years 10 years 10 years: specifications 263 and 463 on lightweight insulating<br />

concrete or gypsum, 273 and 473 on precast concrete or steel;<br />

15 years: specifications 263 and 463 on wood plank, 264 and<br />

464 on lightweight insulating concrete or gypsum; 20 years:<br />

specifications 264 and 464 on wood plank, 274 and 474 on<br />

poured or precast concrete or steel, 273 and 473 on poured<br />

concrete; 20-year specifications are eligible for 15- and 10-year<br />

warranties; 15-year specifications are eligible for 10-year<br />

warranties.<br />

6 Nature of remedy If the wearing surface fails due <strong>to</strong> the effects of weather and JPS will repair leaks in the roofing system using methods Koppers will undertake repairs as long as the repair is<br />

normal wear and tear of the elements and the material is installed determined <strong>to</strong> be suitable at JPS' discretion. “practicable,” i.e., the cost of the repair is less than the<br />

and used in strict accordance with JPS specifications, JPS will be<br />

"remaining value" of the roof on the date the repair is required.<br />

liable for the cost of the material at the time of claim, prorated for<br />

“Remaining value” is the <strong>to</strong>tal cost of roof installation reduced by<br />

service <strong>to</strong> date of claim. JPS will furnish the owner Hi-Tuff roofing<br />

5 percent for each year or part of a year after the effective date<br />

membrane <strong>to</strong> replace the affected area.<br />

with no deduction for the cost of any previous warranty repair. If<br />

Koppers believes repair is not practicable, payment of remaining<br />

value will be owner's sole and exclusive remedy.<br />

7 Monetary limitations JPS' liability limited <strong>to</strong> the cost of the material at the time of claim, None stated. Koppers is not liable <strong>to</strong> pay for a repair that Koppers believes<br />

prorated for service <strong>to</strong> date of claim.<br />

will cost more than the <strong>to</strong>tal cost of the roof installation (BUR<br />

membrane, flashing, and Styrofoam) reduced by 5 percent for<br />

each year or part thereof.<br />

8 Notification requirements Written notification <strong>to</strong> JPS Warranty Services Department, Written notification of leaks must be delivered <strong>to</strong> JPS Warranty Call Koppers at 1-800-468-9629 within 72 hours of discovery of<br />

Holyoke, MA 01040-2800, within 30 days of the discovery of any Services Department, Holyoke, MA 01040-2800, within 30 days of leak or insulation failure and provide written notice by registered<br />

wearing surface failure in the membrane discovery. mail <strong>to</strong> Koppers Industries, Inc., 436 Seventh Avenue,<br />

Pittsburgh, PA 15219, Attention: <strong>Roof</strong>ing Cus<strong>to</strong>mer Service<br />

Department.<br />

9 Exclusive or additional Warranty and remedies are exclusive and in lieu of any other Warranty and remedies are exclusive and in lieu of any other Remedy provided in warranty is sole and exclusive remedy at<br />

remedy remedy or warranty whether written, oral, implied, or statu<strong>to</strong>ry; remedy or warranty whether written, oral, implied or statu<strong>to</strong>ry; law or in equity for defects in material supplied by Koppers or<br />

excludes UCC warranties. excludes UCC warranties. Dow and workmanship of the contrac<strong>to</strong>r. Koppers not liable for<br />

consequential, incidental, or other damages under any theory of<br />

law; excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty JPS' determination; JPS' sole judgment whether specific JPS' determination; JPS' sole judgment whether specific Koppers determines whether repair is practical. Thermal<br />

applicability exclusions and conditions that make warranty null and void occur exclusions and conditions that make warranty null and void occur resistance of insulation tested according <strong>to</strong> ASTM C518-85.<br />

(See Special Features/Conditions.)<br />

12 Specific exclusions from 1, 2, 3, 16, 23 1, 3, 5, 7, 17. Warranty states that specific Condition M also 1, 2, 3, 4, 5, 7, 8, 9, 10, 12, 15, 16, 17, 18, 22, 23<br />

coverage (see Item 12 in<br />

makes the warranty inapplicable.<br />

Introduction)<br />

786


13 Wind coverage/exclusions Warranty excludes gale-force winds Warranty excludes winds of peak gust speed of ___ mph The warranty covers roof damage resulting from wind speeds up<br />

measured 10 meters above the ground, hurricanes, and<br />

<strong>to</strong> 70 miles per hour.<br />

<strong>to</strong>rnadoes.<br />

14 Specific conditions <strong>to</strong> make B, C, F, G, I B, C, F, G, H, I B (except emergency repairs), G<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain 5 years: $150; 10 years: $300 10 years: $6.00/square 10 yrs: $9.00/sq; 15 yrs: $10.50/sq; 20 yrs: $13.00/sq<br />

16 Minimum charge 5 years: $150; 10 years: $300 10 years: $450 10 yrs: $800; 15 yrs: $900; 20 yrs: $1,000<br />

17 Ineligible structure or Residential buildings Residential buildings Cooler/freezer buildings, private residences<br />

building use<br />

18 Pre-construction notice and None Contrac<strong>to</strong>r submits request <strong>to</strong> JPS for approval of warranty form, The contrac<strong>to</strong>r telephones application <strong>to</strong> Koppers 14 days prior<br />

approval requirements along with diagram and details. <strong>to</strong> job start. If project is approved, contrac<strong>to</strong>r is sent application<br />

for warranty.<br />

19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy JPS technical representative makes on-site inspection after JPS technical representative makes on-site inspection after Koppers technical service personnel or designated<br />

application prior <strong>to</strong> issuance of warranty; no charge. application prior <strong>to</strong> issuance of warranty; no charge. representative may make on-site inspections prior <strong>to</strong> and during<br />

application. Inspection of insulation installation and a final<br />

inspection prior <strong>to</strong> warranty issuance and a two-year inspection<br />

are required; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r is normally obligated <strong>to</strong> make repairs <strong>to</strong> all leaks, any Contrac<strong>to</strong>r is normally obligated <strong>to</strong> make repairs <strong>to</strong> all leaks, any Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workman-ship<br />

obligation defects, and workmanship deficiencies for two years. defects, and workmanship deficiencies for two years. deficiencies for two years.<br />

22 Backed by named insurance No No No; Koppers indicates that it does not carry insurance covering<br />

or surety<br />

its warranty obligations.<br />

23 Issuing entity manufactures JPS manufactures and sells the product. JPS manufactures and sells the product. Koppers manufactures and sells product.<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability Warranty is transferable; consult JPS for conditions of Warranty is transferable; consult JPS for conditions of Warranty states that original named owner is covered and not<br />

transferability. Conditions are noted in JPS maintenance transferability. Conditions are noted in JPS maintenance any tenant, purchaser, or successor without prior written notice<br />

instructions. instructions. <strong>to</strong> and approval from Koppers.<br />

26 Special features/condition Any controversy or claim arising out of or relating <strong>to</strong> warranty shall Any controversy or claim arising out of or relating <strong>to</strong> warranty shall Koppers does not certify that the work is actually free from<br />

be settled by arbitration in accordance with the construction be settled by arbitration in accordance with the construction defect. If Koppers' investigation of a reported problem reveals<br />

industry rules of the American Arbitration <strong>Association</strong> at the industry rules of the American Arbitration <strong>Association</strong> at the the problem <strong>to</strong> be outside the scope<br />

Bos<strong>to</strong>n, Mass. regional office, and judgment upon the award Bos<strong>to</strong>n, Mass. regional office, and judgment upon the award of the warranty, investigation and repair costs shall be paid by<br />

rendered by the arbitra<strong>to</strong>rs may be entered in any court having rendered by the arbitra<strong>to</strong>rs may be entered in any court having the owner. "Thermal resistance" of Styrofoam Brand insulation<br />

jurisdiction thereof. No representative of JPS has authority <strong>to</strong> jurisdiction thereof. No representative of JPS has authority <strong>to</strong> shall be tested, at owner's expense, according <strong>to</strong> ASTM<br />

make any representations or promises, except as stated in make any representations or promises, except as stated in C518-85. Should testing prove insulation <strong>to</strong> have lost greater<br />

warranty. warranty. than 10 percent of thermal resistance, owner will be reimbursed<br />

for testing cost and insulation replacement.<br />

Warranty will be governed by the laws of Pennsylvania. Any<br />

action or breach of this agreement must be commenced within<br />

one year after such breach occurs or is discovered.<br />

27 Executed by owner Yes Yes<br />

787


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Koppers Industries, Inc. Koppers Industries, Inc. Koppers Industries, Inc.<br />

2 Title, original publication “Koppers Classic Warranty;” January 1, 2000; CRD-C-109 “Koppers Standard Warranty;” January 1, 2000; CRD B-109 “Modified Bitumen <strong>Roof</strong> Membrane Warranty;” January 1, 2000;<br />

date, and identifying symbol,<br />

CRD-D-109<br />

if any<br />

3 Product, specification, or Built-up roofing specifications: 200 Series, 400 Series Built-Up roofing specifications: 200 Series and 400 Series Modified Bitumen specifications: 401, 402, 403, 404, 405, 412,<br />

system covered 414, 415, 416, 417.<br />

4 Scope of coverage Materials and workmanship; Koppers agrees <strong>to</strong> provide roofing Materials and workmanship; Koppers agrees <strong>to</strong> provide roofing Materials and workmanship; Koppers agrees <strong>to</strong> provide roofing<br />

repairs <strong>to</strong> correct all roof water leaks that may occur from ordinary repairs <strong>to</strong> correct all roof water leaks that may occur from ordinary repairs <strong>to</strong> correct all roof water leaks that may occur from<br />

wear and tear of the elements, defects in built-up roofing, flashing, wear and tear of the elements, defects in built-up roofing or defects in modified bitumen material supplied by Koppers and<br />

or insulation supplied by Koppers, and workmanship of the original flashing materials supplied by Koppers, and workmanship of the workmanship of the original Koppers eligible roofing contrac<strong>to</strong>r<br />

roofing contrac<strong>to</strong>r in installing Koppers built-up roofing, flashing original roofing contrac<strong>to</strong>r in installing Koppers built-up roofing and in installing Koppers’ modified bitumen products. A roof water<br />

and insulation. A roof water leak is defined as water passing flashing materials. A roof water leak is defined as water passing leak is defined as water passing through the roofing or flashing<br />

through the roofing or flashing membrane and in<strong>to</strong> the interior of through the roofing or flashing membrane and in<strong>to</strong> the interior of membrane and in<strong>to</strong> the interior of the building. Warranty does<br />

the building. Warranty does not cover correction of any condition the building. Warranty does not cover correction of any condition not cover correction of any condition other than roof water leaks,<br />

other than roof water leaks, including blisters, clogged drains, other than roof water leaks, including correction of blisters, including ridging or slippage.<br />

ridging, bitumen drippage or migration.<br />

clogged drains, ridging, bitumen drippage, or migration.<br />

5 Length of coverage 5, 10, 15 or 20 years. Up <strong>to</strong> 20 years for 200 and 400 Series 4-Ply 5, 10, 15 or 20 years. 15 years: 200 and 400 Series 3-ply 5, 10, or 12 years<br />

Systems; Up <strong>to</strong> 15 years for 200 and 400 Series 3-Ply Systems, systems, with the exception of 3-ply systems over nailable decks<br />

with the exception of 3-Ply Systems over nailable decks in which in which case the maximum length of coverage is 10 years. 20<br />

case the maximum length of coverage is 10 years.<br />

years: 200 and 400 Series 4-ply systems<br />

6 Nature of remedy Koppers will undertake repairs so long as the repair is considered Koppers will schedule a roof inspection and arrange for any Koppers will schedule a roof inspection and arrange for any<br />

“prudent” (i.e., Koppers considers that the cost of the repair is less repairs that are covered by the warranty repairs which are covered by warranty.<br />

than the “remaining value” of the roof on the date the repair is<br />

required. “Remaining value” is the <strong>to</strong>tal cost of roof installation,<br />

reduced by 5 percent for each year or part of a year after the<br />

effective date, with no deduction for the cost of any previous<br />

warranty repair). If Koppers believes repair is not prudent,<br />

payment of remaining value will be the owner’s sole and exclusive<br />

remedy and shall relieve Koppers of all further liability under the<br />

warranty.<br />

7 Monetary limitations Koppers is not liable <strong>to</strong> pay for a repair that Koppers believes will Repair limit is stated in the warranty when issued. Repair Limit is stated in the warranty when issued.<br />

cost more than the <strong>to</strong>tal cost of the roof installation (BUR<br />

membrane, flashing, and insulation) reduced by 5 percent for each<br />

year or part thereof.<br />

8 Notification requirements Call Koppers at 800-468-9629 within 72 hours of discovery of leak Call Koppers at 800-468-9629 within 72 hours of the discovery of a Call Koppers at 800-468-9629 within 72 hours of discovery of<br />

and provide written notice within 30 days by registered mail <strong>to</strong> leak and provide written notice within 30 days <strong>to</strong> Koppers leak and provide written notice within 30 days <strong>to</strong> Koppers<br />

Koppers Industries, Inc. 436 Seventh Avenue, Pittsburgh, PA Industries, Inc., 436 Seventh Avenue, Pittsburgh, PA 15219, Industries, Inc. 436 Seventh Avenue, Pittsburgh, PA 15219,<br />

15219, attention: Commercial <strong>Roof</strong>ing Department. Attention: Commercial <strong>Roof</strong>ing Department. attention: Commercial <strong>Roof</strong>ing Department.<br />

9 Exclusive or additional Warranty obligation of Koppers and remedy provided by warranty Warranty obligation of Koppers and remedy provided by warranty Warranty obligation of Koppers and remedy provided by<br />

remedy is sole and exclusive remedy at law or equity for defects in is sole and exclusive remedy at law or equity for defects in warranty is sole and exclusive remedy at law or equity for<br />

material supplied by Koppers and workmanship of the contrac<strong>to</strong>r; material supplied by Koppers and workmanship of the contrac<strong>to</strong>r; defects in material supplied by Koppers and workmanship of the<br />

warranty includes the complete and exclusive agreement with warranty includes the complete and exclusive agreement with contrac<strong>to</strong>r; warranty includes the complete and exclusive<br />

Koppers and supercedes any and all prior oral or written Koppers and supercedes any and all prior oral or written agreement with Koppers and supercedes any and all prior oral<br />

agreements or representations; excludes UCC warranties. agreements or representations; excludes UCC warranties. or written agreements or representations; excludes UCC<br />

warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Koppers’ determination Kopper’s determination Koppers’ determination<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 15, 16, 17, 18, 22, 23 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 15, 16, 17, 18, 22, 23 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 16, 17, 18, 22, 23<br />

coverage (see Item 12 in<br />

Introduction)<br />

788


13 Wind coverage/exclusions Warranty excludes wind damage, hurricanes and <strong>to</strong>rnadoes. Warranty excludes wind damage, hurricanes and <strong>to</strong>rnadoes. Warranty excludes wind damage, hurricanes and <strong>to</strong>rnadoes.<br />

Koppers indicates that there is no coverage for damage caused by Koppers indicates that there is no coverage for damage caused by Koppers indicates that there is no coverage for damage caused<br />

wind. wind. by wind<br />

14 Specific conditions <strong>to</strong> make B, C, F, H, J, M, O B, C, H, J, M, N, O B, C, F, H, J, M, O<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain 20 years: $15.00/square $650 $6.00/square<br />

16 Minimum charge 5 years: $700; 10 years: $800; 20 years: $1,000 5 years: $350; 10 years: $550; 20 years: $650 5 years: $350; 10 years: $550; 12 years: $600<br />

17 Ineligible structure or Residential Residential Residential<br />

building use<br />

18 Pre-construction notice and Warranty application is submitted <strong>to</strong> Koppers for approval and Warranty application is submitted <strong>to</strong> Koppers for approval and Warranty application is submitted <strong>to</strong> Koppers for approval and<br />

approval requirements upon approval by Koppers, the contrac<strong>to</strong>r is notified. This is upon approval by Koppers, the contrac<strong>to</strong>r is notified. This is contrac<strong>to</strong>r is notified upon approval by Koppers. This is<br />

followed by acknowledgment through signed agreements. followed by acknowledgment through signed agreements followed by acknowledgment through signed agreements.<br />

19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy Koppers representatives or authorized inspec<strong>to</strong>rs make on-site Koppers representatives or authorized inspec<strong>to</strong>rs make on-site Koppers representatives or authorized inspec<strong>to</strong>rs make on-site<br />

inspections prior <strong>to</strong> and during application as deemed necessary inspections prior <strong>to</strong> and during application as deemed necessary inspections prior <strong>to</strong> and during application as deemed<br />

by Koppers. Koppers makes inspections after completion, prior <strong>to</strong> by Koppers. Koppers will make on-site inspections after necessary by Koppers. Koppers makes inspections after<br />

issuing warranty, as well as two years after issuance of warranty; completion, prior <strong>to</strong> issuing warranty, as well as two years after completion, prior <strong>to</strong> issuing warranty, as well as two years after<br />

no charge. issuance of warranty; no charge. issuance of warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> all leaks and defects Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> all leaks and defects Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> all leaks and defects<br />

obligation and workmanship deficiencies for two years. and workmanship deficiencies for two years. and workmanship deficiencies for two years.<br />

22 Backed by named insurance No; Koppers indicates it does not carry insurance conveying its No; Koppers indicates it does not carry insurance conveying its No; Koppers indicates it does not carry insurance conveying its<br />

or surety warranty obligations. warranty obligations. warranty obligations.<br />

23 Issuing entity manufactures Koppers manufactures and sells product. Koppers manufactures and sells the product. Koppers manufactures and sells product.<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability Warranty states that original named owner is covered and not any Warranty states that original named owner is covered and not any Warranty states that original named owner is covered and not<br />

tenant, purchaser, or successor without prior written notice <strong>to</strong> and tenant, purchaser, or successor without prior written notice <strong>to</strong> and any tenant, purchaser, or successor without prior written notice<br />

approval from Koppers. Warranty may be assigned or transferred approval from Koppers. Warranty may be assigned or transferred <strong>to</strong> and approval from Koppers. Warranty may be assigned or<br />

<strong>to</strong> such tenant, purchaser, or successor only if: (1) the owner <strong>to</strong> such tenant, purchaser, or successor only if: (1) the owner transferred <strong>to</strong> such tenant, purchaser, or successor only if: (1)<br />

provides written notification of any transfer of ownership <strong>to</strong> provides written notification of any transfer of ownership <strong>to</strong> the owner provides written notification of any transfer of<br />

Koppers within 30 days of such transfer; (2) Koppers is given Koppers within 30 days of such transfer; (2) Koppers is given ownership <strong>to</strong> Koppers within 30 days of such transfer; (2)<br />

opportunity <strong>to</strong> inspect the roof at its discretion; and (3) any repairs opportunity <strong>to</strong> inspect the roof at its discretion; and (3) any repairs Koppers is given opportunity <strong>to</strong> inspect the roof at its discretion;<br />

required by Koppers are made. required by Koppers are made. and (3) any repairs required by Koppers are made<br />

26 Special features/condition Annual roof inspections are the responsibility of the building Annual roof inspections are the responsibility of the building Annual roof inspections are the responsibility of the building<br />

owner. Owner must comply with Koppers care and maintenance owner. Owner must comply with Koppers care and maintenance owner. Owner must comply with Koppers care and<br />

recommendations, including a complete recoating of the flashing recommendations, including a complete recoating of the flashing maintenance recommendations, including a complete recoating<br />

system, using a Koppers aluminum roof coating, every five years system, using a Koppers aluminum roof coating, every five years of the flashing system, using a Koppers aluminum roof coating,<br />

on flashing specifications 168, 172, 180, and as needed on 174 on flashing specifications 168, 172, 180, and as needed on 174 every five years on flashing specifications 168, 172, 180, and as<br />

and 182. and 182.\ needed on 174 and 182.<br />

Warranty will be governed by the laws of the Commonwealth of Warranty will be governed by the laws of the Commonwealth of Warranty will be governed by the laws of the Commonwealth<br />

Pennsylvania. By purchase, acceptance or receipt of Koppers Pennsylvania. By purchase, acceptance or receipt of Koppers of Pennsylvania. By purchase, acceptance or receipt of<br />

products and warranty, the Owner accepts the terms, conditions, products and warranty, the Owner accepts the terms, conditions, Koppers products and warranty, the Owner accepts the terms,<br />

limitations and exclusions contained in the Warranty. Any action limitations and exclusions contained in the Warranty. Any action conditions, limitations and exclusions contained in the Warranty.<br />

for breach of warranty must be commenced within one year after for breach of warranty must be commenced within one year after Any action for breach of warranty must be commenced within<br />

such breach occurs or is discovered. such breach occurs or is discovered. one year after such breach occurs or is discovered.<br />

If Koppers’ investigation of a reported problem reveals the If Koppers’ investigation of a reported problem reveals the If Koppers’ investigation of a reported problem reveals the<br />

problem <strong>to</strong> be outside the scope of the warranty, investigation and problem <strong>to</strong> be outside the scope of the warranty, investigation and problem <strong>to</strong> be outside the scope of the warranty, investigation<br />

repair costs shall be paid by owner. A roof sketch should be repair costs shall be paid by owner. and repair costs shall be paid by owner. A roof sketch should<br />

supplied <strong>to</strong> Koppers identifying exact locationsof all additions,<br />

be supplied <strong>to</strong> Koppers identifying exact locations of all<br />

alterations or repairs.<br />

additions, alterations or repairs.<br />

27 Executed by owner No (See Special Features/Conditions). No (See Special Features/Conditions). No (See Special Features/Conditions).<br />

789


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

Identity of issuing entity<br />

1 Mule-Hide Products Mule-Hide Products Mule-Hide Products<br />

2 Title, original publication “Mule-Hide Products Co., Inc. Standard System Warranty for Mule-Hide Membrane Material Warranty; May 1, 1994 Mule-Hide Products Co., Inc. Premium System Warranty for<br />

date, and identifying symbol, Commercial Buildings”; May 1, 1994 Commercial Buildings; May 1, 1994<br />

if any<br />

3 Product, specification, or EPDM systems: ballasted, mechanically attached, fully adhered; EPDM Membranes, Hypalon Membranes, Thermoplastic (PVC) EPDM systems: ballasted, mechanically attached, fully adhered;<br />

system covered Hypalon systems: ballasted, mechanically attached, fully adhered; Membranes Hypalon systems: ballasted, mechanically attached, fully<br />

Thermoplastic (PVC) systems: mechanically attached, fully<br />

adhered; Thermoplastic (PVC) systems: mechanically attached,<br />

adhered<br />

fully adhered<br />

4 Scope of coverage Material and workmanship; Mule-Hide warrants that it will be Material only; Mule-Hide warrants that the Mule-Hide roofing Material and workmanship; Mule-Hide warrants that it will be<br />

responsible for the repair of leaks in the Mule-Hide Standard membrane is free of manufacturing defects at the time of delivery, responsible for the repair of leaks in the Mule-Hide Standard<br />

System. For purposes of this warranty, System means only the that the membrane will not prematurely deteriorate due <strong>to</strong> System. For purposes of this warranty, System means only the<br />

membrane, other components supplied by Mule-Hide, and will weathering <strong>to</strong> the extent that it becomes incapable of maintaining membrane, other components supplied by Mule-Hide, and will<br />

exclude the roof insulation, deck, support system, and metal a watertight condition as a single-ply roofing membrane, and that exclude the roof insulation, deck, support system, and metal<br />

flashings. the membrane is manufactured in accordance with the flashings.<br />

manufacturer's specifications.<br />

5 Length of coverage 10 or 15 years EPDM Membrane: 5, 10, 15, 20 years (black only); Hypalon 10 or 15 years<br />

membrane: 5, 10, 15 years; PVC Membrane: 5, 10, 15 years<br />

6 Nature of remedy The owner's remedies and Mule-Hide's liability shall be limited <strong>to</strong> If the membrane prematurely fails due <strong>to</strong> weathering or The owner's remedies and Mule-Hide's liability shall be limited<br />

Mule-Hide's repair of the system using methods determined <strong>to</strong> be manufacturing defects, Mule-Hide will be liable for the cost of the <strong>to</strong> Mule-Hide's repair of the system using methods determined<br />

suitable at Mule-Hide's discretion. material affected at the time of the claim, prorated for service <strong>to</strong> <strong>to</strong> be suitable at Mule-Hide's discretion.<br />

date of the claim. Mule-Hide will furnish owner repair material for<br />

the affected area or credit <strong>to</strong> be applied <strong>to</strong>ward the purchase of a<br />

new membrane. Warranty does not cover the cost of installation<br />

of the repair material. Labor and accessories, including but not<br />

limited <strong>to</strong> flashings, adhesives and caulking are not covered.<br />

7 Monetary limitations None stated. The maximum prorated value allowed for repair or credit shall not None stated<br />

exceed the original purchase price of the membrane.<br />

8 Notification requirements Written notice <strong>to</strong> Mule-Hide and contrac<strong>to</strong>r within ten days after Written notification within 30 days of a failure in the membrane or Written notice <strong>to</strong> Mule-Hide and contrac<strong>to</strong>r within ten days after<br />

owner or any of its agents discover or a reasonable person in purported defect by certified mail <strong>to</strong> Mule-Hide Products Co., Inc., owner or any of its agents discover or a reasonable person in<br />

owner's or agent's position would have discovered any leak. P.O. Box 1057, Beloit, WI 53512-1057, Attention: Warranty owner's or agent's position would have discovered any leak.<br />

Department<br />

9 Exclusive or additional Warranty is the owner's sole and exclusive remedy for failure of Warranty and remedies provided are exclusive and in lieu of any Warranty is the owner's sole and exclusive remedy<br />

remedy the Mule-Hide Standard System; warranty supersedes any and all other remedy or warranty, whether written, oral, implied or for failure of the Mule-Hide Standard System; warranty<br />

other express warranties; Mule-Hide shall not be liable under any statu<strong>to</strong>ry; excludes UCC warranties. supersedes any and all other express warranties; Mule-Hide<br />

circumstance or theory of action, including contract, <strong>to</strong>rt, products<br />

shall not be liable under any circumstance or theory of action,<br />

liability, or otherwise for any incidental or consequential damages,<br />

including contract, <strong>to</strong>rt, products liability, or otherwise for any<br />

including loss of profit or damage <strong>to</strong> building, merchandise and<br />

incidental or consequential damages, including loss of profit or<br />

loss or damage caused or contributed <strong>to</strong> by Mule-Hide's approval<br />

damage <strong>to</strong> building, merchandise and loss or damage caused<br />

of the contrac<strong>to</strong>r or inspection of, or omission <strong>to</strong> inspect, the<br />

building roof; excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

or contributed <strong>to</strong> by Mule-Hide's approval of the contrac<strong>to</strong>r or<br />

inspection of, or omission <strong>to</strong> inspect, the building roof; excludes<br />

UCC warranties.<br />

11 Determination of warranty Mule-Hide's determination (See Special Features/ Conditions.) Mule-Hide's determination Mule-Hide's determination (See Special Features/ Conditions.)<br />

applicability<br />

12 Specific exclusions from 1, 3, 4, 5, 7, 10, 11, 13, 16, 22, 23, 24. (Warranty also excludes 1, 2, 3, 12, 16, 23 1, 3, 4, 5, 7, 10, 11, 13, 16, 22, 23, 24. (Warranty also excludes<br />

coverage (see Item 12 in the infestation or presence of insects or an animal.) the infestation or presence of insects or an animal.)<br />

Introduction)<br />

13 Wind coverage/exclusions Warranty excludes wind speeds in excess of 55 mph, hurricanes, Warranty excludes wind, hurricanes, and <strong>to</strong>rnadoes. Mule-Hide Warranty excludes wind speeds in excess of 55 mph,<br />

and <strong>to</strong>rnadoes. Mule-Hide indicates that warranty covers roof indicates that there is no coverage for damage caused by wind. hurricanes, and <strong>to</strong>rnadoes. Mule-Hide indicates that warranty<br />

damage resulting from wind speeds up <strong>to</strong> 55 mph.<br />

covers roof damage resulting from wind speeds up <strong>to</strong> 55 mph.<br />

790


14 Specific conditions <strong>to</strong> make B, C, F (warranty references owner's care and maintenance C B, C, F (warranty references owner's care and maintenance<br />

the warranty ineffective or information), G, K. Warranty also is canceled if there is an internal information), G, K. Warranty also is canceled if there is an<br />

null and void (see Item 14 in positive pressure condition that causes or contributes <strong>to</strong> a partial internal positive pressure condition that causes or contributes <strong>to</strong><br />

Introduction) or <strong>to</strong>tal failure of the roof. a partial or <strong>to</strong>tal failure of the roof.<br />

15 Cost <strong>to</strong> obtain 10 years: $5.00/square for Hypalon, thermoplastics; 10 yrs: $25.00; 20 yrs: $2.00/sq (EPDM black only) 10 yrs: $8.00/sq; 15 yrs: $14.00/sq<br />

$6.00/square for EPDM<br />

16 Minimum charge 10 years: $500; 15 years: $900 10 years: $25.00 10 years: $800; 15 years: $1,250<br />

17 Ineligible structure or Residences None Residences<br />

building use<br />

18 Pre-construction notice and Submit pre-job survey form and warranty application <strong>to</strong> Mule-Hide Submit pre-job survey form and warranty application <strong>to</strong> Mule-Hide Submit pre-job survey form and warranty application <strong>to</strong> Muleapproval<br />

requirements Products Co. for approval prior <strong>to</strong> job commencement. Products Co. prior <strong>to</strong> job commencement. Hide Products Co. for approval prior <strong>to</strong> job commencement.<br />

19 Approved, authorized, or Yes No Yes<br />

licensed requirements<br />

20 Job inspection policy Mule-Hide field representative makes on site inspections prior <strong>to</strong>, No on-site inspections Mule-Hide field representative makes on site inspections prior<br />

during, and after completion and two years after issuance of<br />

<strong>to</strong>, during, and after completion and two years after issuance of<br />

warranty; no charge.<br />

warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship None; material-only warranty Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

obligation deficiencies for two years. deficiencies for two years.<br />

22 Backed by named insurance No; Mule-Hide indicates that it does not carry insurance covering No; Mule-Hide indicates that it does not carry insurance covering No; Mule-Hide indicates that it does not carry insurance<br />

or surety its warranty obligations. its warranty obligations. covering its warranty obligations.<br />

23 Issuing entity manufactures Mule-Hide sells the product only. Mule-Hide sells the product only. Mule-Hide sells the product only<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability Warranty is not assignable by owner; however, Mule-Hide may No restrictions stated. Warranty is not assignable by owner; however, Mule-Hide may<br />

authorize a new warranty if a written request for a new warranty is<br />

authorize a new warranty if a written request for a new warranty<br />

submitted <strong>to</strong> Mule-Hide by the owner and the owner is in good<br />

is submitted <strong>to</strong> Mule-Hide by the owner and the owner is in good<br />

standing under warranty, the roof is inspected by Mule-Hide within<br />

standing un-der warranty, the roof is inspected by Mule-Hide<br />

a 30-day period prior <strong>to</strong> the proposed effective date of the new<br />

within a 30-day period prior <strong>to</strong> the proposed effective date of the<br />

warranty and the condition of the roof is approved by Mule-Hide<br />

new warranty and the condition of the roof is approved by Muleand<br />

an administration and reinspection fee in an amount<br />

Hide and an administration and reinspection fee in an amount<br />

determined by Mule-Hide is paid <strong>to</strong> Mule-Hide. A new warranty<br />

determined by Mule-Hide is paid <strong>to</strong> Mule-Hide. A new warranty<br />

will then be issued <strong>to</strong> and executed by the new owner for the<br />

will then be issued <strong>to</strong> and executed by the new owner for the<br />

remaining term of warranty containing the terms and conditions<br />

remaining term of warranty containing the terms and conditions<br />

required by Mule-Hide.<br />

required by Mule-Hide.<br />

26 Special features/condition Any dispute, controversy, or claim between owner and Mule-Hide No representative has the authority <strong>to</strong> make any representations Any dispute, controversy, or claim between owner and Mulearising<br />

out of or related <strong>to</strong> warranty or the building shall be settled or promises except as stated in warranty. Hide arising out of or related <strong>to</strong> warranty or the building shall be<br />

by final and binding arbitration in accordance with the rules of the<br />

settled by final and binding arbitration in accordance with the<br />

American Arbitration <strong>Association</strong> for the Construction Industry. A<br />

rules of the American Arbitration <strong>Association</strong> for the<br />

reinspection fee (in accordance with Mule-Hide's standard Construction Industry. A reinspection fee (in<br />

charges) shall be paid by Owner <strong>to</strong> Mule-Hide in the event the<br />

accordance with Mule-Hide's standard charges) shall be paid by<br />

cause of the leak is not covered by the warranty.<br />

Owner <strong>to</strong> Mule-Hide in the event the cause of the leak is not<br />

Mule-Hide is not liable for any promise, representation or other<br />

covered by the warranty.<br />

responsibility of the contrac<strong>to</strong>r. Warranty is not binding upon<br />

Mule-Hide is not liable for any promise, representation or other<br />

Mule-Hide unless executed by an executive officer of Mule-Hide.<br />

responsibility of the contrac<strong>to</strong>r. Warranty is not binding upon<br />

No representative or employee of Mule-Hide may vary this<br />

Mule-Hide unless executed by an executive officer of Mule-Hide.<br />

warranty without the prior written consent of the board of direc<strong>to</strong>rs<br />

No representative or employee of Mule-Hide may vary this<br />

of Mule-Hide.<br />

warranty without the prior written consent of the board of<br />

The owner acknowledges that owner had a duty <strong>to</strong> exercise<br />

direc<strong>to</strong>rs of Mule-Hide.<br />

reasonable care in the selection of a contrac<strong>to</strong>r.<br />

The owner acknowledges that owner had a duty <strong>to</strong> exercise<br />

reasonable care in the selection of a contrac<strong>to</strong>r.<br />

27 Executed by owner Yes; owner expressly accepts Mule-Hide's terms, conditions, and No Yes; owner expressly accepts Mule-Hide's terms, conditions,<br />

limitations.<br />

and limitations.<br />

791


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entit Omnova Solutions, Inc. Omnova Solutions, Inc. Omnova Solultions, Inc.<br />

2 Title, original publication GenFlex <strong>Roof</strong>ing Systems “EPDM <strong>Roof</strong>ing System Warranty;” GenFlex <strong>Roof</strong>ing Systems “Limited Membrane Only Warranty;” GenFlex <strong>Roof</strong>ing Systems “Thermoplastic Full <strong>Roof</strong>ing System<br />

date, and identifying symbol, January 1, 2000 January 1, 2000. Warranty;” January 1, 2000<br />

if any<br />

3 Product, specification, or GenFlex EPDM GenFlex RM, GenFlex TPO, GenFlex EPDM GenFlex RM; GenFlex TPO<br />

system covered<br />

4 Scope of coverage Materials and workmanship; Omnova warrants that it will repair Material only; Omnova warrants that the roofing membrane will not Material and workmanship; Omnova warrants that it will repair<br />

any leak in the GenFlex EPDM roofing system caused by a defect deteriorate <strong>to</strong> the point of causing leaks through the membrane any leak in the GenFlex RM or GenFlex TPO <strong>Roof</strong>ing System<br />

in GenFlex brand materials or workmanship of the GenFlex due <strong>to</strong> normal weathering. Warranty applies only <strong>to</strong> the roofing caused by a defect in GenFlex brand materials or workmanship<br />

authorized contrac<strong>to</strong>r. The roofing system consists of GenFlex membrane and does not apply <strong>to</strong> labor, materials, or construction of the GenFlex authorized contrac<strong>to</strong>r. The roofing system<br />

EPDM brand membrane, GenFlex brand insulation, fasteners, details. consists of GenFlex RM or GenFlex TPO brand membrane,<br />

adhesives, sealants, flashings, fastener plates, metal bars and<br />

GenFlex brand insulation, fasteners, adhesives, sealants,<br />

related GenFlex EPDM brand accessory items when used in<br />

flashings, fastener plates, metal bars and related GenFlex brand<br />

accordance with GenFlex’s published written technical<br />

accessory items when used in accordance with GenFlex’s<br />

specifications.<br />

published written technical specifications.<br />

5 Length of coverage 5, 10, 15, or 20 years. In order <strong>to</strong> obtain 20 year coverage, 5, 10, 15 or 20 years. 5, 10, 15, or 20 years. In order <strong>to</strong> obtain 20 year coverage,<br />

thermoplastic membranes must be at least .060 mils.<br />

thermoplastic membranes must be at least .060 mils. GenFlex<br />

RM roof systems are not eligible for 20 year warranty.<br />

6 Nature of remedy If there is a leak caused by a defect in GenFlex brand materials or Omnova will, at its option, either repair the membrane or issue If there is a leak caused by a defect in GenFlex brand materials<br />

workmanship, Omnova will repair the leak. credit against the purchase of a new roofing membrane from or workmanship, Omnova will repair the leak.<br />

Omnova, prorated based on months of service.<br />

7 Monetary limitations None stated Credit issued by Omnova shall be determined by multiplying the None stated.<br />

current price of a replacement membrane by a fraction, the<br />

numera<strong>to</strong>r of which is the remaining months of the warranty and<br />

the denomina<strong>to</strong>r of which is the <strong>to</strong>tal number of months the<br />

warranty is <strong>to</strong> be in effect.<br />

8 Notification requirements Written notice within 30 days of discovery of any leak and any Written notice within 30 days of discovery of any leak and any Written notice within 30 days of discovery of any leak and any<br />

warranty claim by certified mail <strong>to</strong> GenFlex <strong>Roof</strong>ing Systems, 1722 warranty claim by certified mail <strong>to</strong> GenFlex <strong>Roof</strong>ing Systems, 1722 warranty claim by certified mail <strong>to</strong> GenFlex <strong>Roof</strong>ing Systems,<br />

Indian Wood Circle, Suite A, Maumee, Ohio 43537. Indian Wood Circle, Suite A, Maumee, Ohio 43537. 1722 Indian Wood Circle, Suite A, Maumee, Ohio 43537.<br />

9 Exclusive or additional Remedy stated in warranty is sole and exclusive remedy for failure Remedy stated in warranty is the sole and exclusive remedy for Remedy stated in warranty is sole and exclusive remedy for<br />

remedy of the GenFlex EPDM roofing system; no other express failure of the roofing membrane; no other express warranties; failure of the GenFlex RM or TPO roofing system; no other<br />

warranties; excludes UCC warranties. excludes UCC warranties. express warranties; excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Omnova’s determination Omnova’s determination Omnova’s determination<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 7, 9, 10, 11, 12 (see Special Features/Conditions), 1, 2, 3, 4, 5, 6, 7, 9, 10, 11, 12 (see Special Features/Conditions), 1, 2, 3, 4, 5, 6, 7, 9, 10, 11, 12 (see Special<br />

coverage (see Item 12 in 13, 17, 24. Warranty also specifically excludes damages caused 13, 17, 24. Warranty also specifically excludes damages caused Features/Conditions), 13, 17, 24. Warranty also specifically<br />

Introduction) by insects and animals. by insects and animals. excludes damages caused by insects and animals.<br />

13 Wind coverage/exclusions Omnova indicates warranty covers roof damage resulting from Omnova indicates warranty covers roof damage resulting from Omnova indicates warranty covers roof damage resulting from<br />

wind speeds up <strong>to</strong> 54 mph. Warranty excludes roof damage wind speeds up <strong>to</strong> 54 mph. Warranty excludes roof damage wind speeds up <strong>to</strong> 54 mph. Warranty excludes roof damage<br />

resulting from wind gusts in excess of 54 mph and hurricanes. resulting from wind gusts in excess of 54 mph and hurricanes resulting from wind gusts in excess of 54 mph and hurricanes.<br />

14 Specific conditions <strong>to</strong> make B, C (warranty may be suspended if owner fails <strong>to</strong> pay the B, C (warranty may be suspended if owner fails <strong>to</strong> pay the B, C (warranty may be suspended if owner fails <strong>to</strong> pay the<br />

the warranty ineffective or prescribed warranty fee or if owner fails <strong>to</strong> reimburse Omnova for prescribed warranty fee or if owner fails <strong>to</strong> reimburse Omnova for prescribed warranty fee or if owner fails <strong>to</strong> reimburse Omnova<br />

null and void (see Item 14 in claim investigation and repair costs if Omnova’s investigation claim investigation and repair costs if Omnova’s investigation for claim investigation and repair costs if Omnova’s investigation<br />

Introduction) reveals that Omnova is not responsible for owner’s claim), D. reveals that Omnova is not responsible for owner’s claim), D reveals that Omnova is not responsible for owner’s claim), D<br />

15 Cost <strong>to</strong> obtain 5 years: $2.00/square; 10 years: $4.00/square None 5 years: $2.00/square; 10 years: $4.00/square<br />

15 years: $7.00/square; 20 years: $10.00 15 years: $7.00/square; 20 years: $10.00/square<br />

792


16 Minimum charge 5 years: $300; 10 years: $350; 15 years: $400 10 years: $50.00; 15 years: $100.00; 20 years: $200 5 years: $300; 10 years: $350; 15 years: $400<br />

17 Ineligible structure or Private single-family residences, walking decks, patios, plaza Private residences, patios and plaza decks Private single-family residences, walking decks, patios, plaza<br />

building use decks decks<br />

18 Pre-construction notice and Authorized contrac<strong>to</strong>r must submit pre-job survey form <strong>to</strong> GenFlex Authorized contrac<strong>to</strong>r must submit pre-job survey form <strong>to</strong> GenFlex Authorized contrac<strong>to</strong>r must submit pre-job survey form <strong>to</strong><br />

approval requirements <strong>Roof</strong>ing Systems technical department in Maumee, Ohio. <strong>Roof</strong>ing Systems two weeks prior <strong>to</strong> job start. GenFlex <strong>Roof</strong>ing Systems technical department in Maumee,<br />

Ohio.<br />

19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy GenFlex technical representative makes on-site inspection after No on-site inspections GenFlex technical representative makes on-site inspection after<br />

completion prior <strong>to</strong> issuance of warranty; no charge.<br />

completion prior <strong>to</strong> issuance of warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

obligation for two years. for two years. deficiencies for two years.<br />

22 Backed by named insurance No No No<br />

or surety<br />

23 Issuing entity manufactures Omnova sells the product only Omnova manufactures and sells GenFlex PVC and TPO and only Omnova manufactures and sells the product.<br />

and/or sells products<br />

sells GenFlex EPDM<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability Warranty may not be transferred upon change of ownership Warranty may not be transferred upon change of ownership Warranty may not be transferred upon change of ownership<br />

unless the owner (a) notifies Omnova in writing of its proposed unless the owner (a) notifies Omnova in writing of its proposed unless the owner (a) notifies Omnova in writing of its proposed<br />

change at least 45 days prior <strong>to</strong> the change; (b) pays Omnova the change at least 45 days prior <strong>to</strong> the change; (b) pays Omnova the change at least 45 days prior <strong>to</strong> the change; (b) pays Omnova<br />

warranty transfer fee which was in effect on the date the warranty warranty transfer fee which was in effect on the date the warranty the warranty transfer fee which was in effect on the date the<br />

was issued and (c) completes all repairs required by Omnova in was issued and (c) completes all repairs required by Omnova in warranty was issued and (c) completes all repairs required by<br />

order <strong>to</strong> correct failures <strong>to</strong> comply with the owner’s obligations order <strong>to</strong> correct failures <strong>to</strong> comply with the owner’s obligations Omnova in order <strong>to</strong> correct failures <strong>to</strong> comply with the owner’s<br />

under the warranty. under the warranty. obligations under the warranty.<br />

26 Special features/condition While Omnova reserves the right <strong>to</strong> suspend its warranty While Omnova reserves the right <strong>to</strong> suspend its warranty While Omnova reserves the right <strong>to</strong> suspend its warranty<br />

obligations if all bills for installation have not been paid, or the obligations if all bills for installation have not been paid, or the obligations if all bills for installation have not been paid, or the<br />

warranty fee has not been paid or if the owner has not reimbursed warranty fee has not been paid or if the owner has not reimbursed warranty fee has not been paid or if the owner has not<br />

Omnova for claim investigation costs, the sole and exclusive Omnova for claim investigation costs, the sole and exclusive reimbursed Omnova for claim investigation costs, the sole and<br />

remedy provision for failure of the roof membrane and exclusion of remedy provision for failure of the roof membrane and exclusion of exclusive remedy provision for failure of the roof membrane and<br />

other warranties, including UCC warranties, remains in full force other warranties, including UCC warranties, remains in full force exclusion of other warranties, including UCC warranties,<br />

and effect. and effect. remains in full force and effect.<br />

Warranty requires compliance with Omnova maintenance and Warranty requires compliance with Omnova maintenance and Warranty requires compliance with Omnova maintenance<br />

care requirements stated on reverse side of warranty, including at care requirements stated on reverse side of warranty, including at and care requirements stated on reverse side of warranty,<br />

least twice yearly inspections; no s<strong>to</strong>rage of materials allowed; least twice yearly inspections; no s<strong>to</strong>rage of materials allowed; including at least twice yearly inspections; no s<strong>to</strong>rage of<br />

regular cleaning in areas where contaminants (i.e., oil, grease, regular cleaning in areas where contaminants (i.e., oil, grease, materials allowed; regular cleaning in areas where contaminants<br />

freon, acids, solvents) potentially harmful <strong>to</strong> the roof system may freon, acids, solvents) potentially harmful <strong>to</strong> the roof system may (i.e., oil, grease, freon, acids, solvents) potentially harmful <strong>to</strong> the<br />

accumulate; protective walkways for traffic, maintenance of accumulate; protective walkways for traffic, maintenance of roof system may accumulate; protective walkways for traffic,<br />

counterflashing, metal work, equipment curb and supports, pitch counterflashing, metal work, equipment curb and supports, pitch maintenance of counterflashing, metal work, equipment curb<br />

pockets, caulking, walk pads, and any other roof <strong>to</strong>p accessories. pockets, caulking, walk pads, and any other roof <strong>to</strong>p accessories. and supports, pitch pockets, caulking, walk pads, and any other<br />

Any claim or dispute between owner and Omnova arising out of Any claim or dispute between owner and Omnova arising out of roof <strong>to</strong>p accessories.<br />

warranty or relating <strong>to</strong> any material supplied or specifically required warranty or relating <strong>to</strong> any material supplied or specifically required Any claim or dispute between owner and Omnova arising out<br />

by Omnova shall be resolved by final and binding arbitration in by Omnova shall be resolved by final and binding arbitration in of warranty or relating <strong>to</strong> any material supplied or specifically<br />

accordance with the rules of the American Arbitration <strong>Association</strong>. accordance with the rules of the American Arbitration <strong>Association</strong>. required by Omnova shall be resolved by final and binding<br />

arbitration in accordance with the rules of the American<br />

Arbitration <strong>Association</strong>.<br />

27 Executed by owner No No No<br />

793


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Performance <strong>Roof</strong> Systems, Inc. (PRS) Performance <strong>Roof</strong> Systems, Inc. (PRS) Performance <strong>Roof</strong> Systems, Inc. (PRS)<br />

2 Title, original publication “Derbigum <strong>Roof</strong> System Guaranty”; Oc<strong>to</strong>ber 1, 1993 “Derbigum <strong>Roof</strong> Membrane Guaranty”; Oc<strong>to</strong>ber 1, 1993 “Derbigum Ten Year Limited Material Warranty”; Oc<strong>to</strong>ber 1,<br />

date, and identifying symbol, 1993<br />

if any<br />

3 Product, specification, or Derbigum XPS, Derbigum XPS/FR, Derbicolor XPS, Derbicolor Derbigum XPS, Derbigum XPS/FR, Derbicolor XPS, Derbicolor Derbigum XPS, Derbigum XPS/FR, Derbicolor XPS, Derbicolor<br />

system covered XPS/FR, Derbigum GP, Derbicolor GP, Derbigum GP/FR, Derbi- XPS/FR, Derbigum GP, Derbicolor GP, Derbigum GP/FR, Derbi- XPS/FR, Derbigum GP, Derbicolor GP, Derbigum GP/FrR,<br />

color GP/FR, Derbibase color GP/FR, Derbibase Derbicolor GP/FR, Derbibase<br />

4 Scope of coverage Material and workmanship; PRS guarantees that it will undertake Material and workmanship; PRS guarantees that it will undertake Material only; PRS warrants that the roofing material and<br />

all actions necessary <strong>to</strong> keep the PRS roof system in a watertight all actions necessary <strong>to</strong> keep the Derbigum roofing and flashing flashing, if properly handled and installed according <strong>to</strong> current<br />

condition and will promptly repair deficiencies in the system's membrane in a watertight condition and will promptly repair PRS specifications, shall be manufactured <strong>to</strong> meet all published<br />

condition that could endanger the membrane's ability <strong>to</strong> remain deficiencies in the membrane’s condition that could endanger the product specifications and will be free of any defect which would<br />

watertight provided that such actions and repairs are a result of membrane's ability <strong>to</strong> remain watertight provided that such actions inhibit such material's ability <strong>to</strong> properly perform.<br />

improper installation of the system, membrane performance, or and repairs are a result of improper installation of the membrane,<br />

ordinary wear and tear by the elements. The roof system only membrane performance, or ordinary wear and tear by the elecovers<br />

materials PRS sells or approves, other than metal. ments. The roof system only covers materials PRS sells or ap-<br />

Building owner is responsible for any costs <strong>to</strong> repair any building proves, other than metal. Building owner is responsible for any<br />

component other than the system if leaks occur. The system costs <strong>to</strong> repair any building component other than the membrane if<br />

consists of all roof components from the roof membrane <strong>to</strong> the leaks occur.<br />

roof deck, including approved base and ply sheets; all adhesives,<br />

insulations, and fasteners; but excluding roof decks and coatings<br />

or surfacing not fac<strong>to</strong>ry applied.<br />

5 Length of coverage 10 years 10 years 10 years<br />

6 Nature of remedy PRS' exclusive responsibility and liability is <strong>to</strong> make repairs that PRS' exclusive responsibility and liability is <strong>to</strong> make repairs that Should the PRS material not properly perform, PRS shall either<br />

may be necessary <strong>to</strong> maintain the roofing system in a watertight may be necessary <strong>to</strong> maintain the roofing system in a watertight refund the original purchase price of the material or replace the<br />

condition. PRS' liability is limited <strong>to</strong> the repair or replacement of condition. PRS' liability is limited <strong>to</strong> the repair or replacement of material found <strong>to</strong> be defective<br />

any portion of the system damaged by leaks that are a result of any portion of the system damaged by leaks that are a result of<br />

covered<br />

covered<br />

7 Monetary limitations No limit <strong>to</strong> PRS' expenditures for damages covered by this No limit <strong>to</strong> PRS' expenditures for damages covered by this PRS' exclusive responsibility and liability will be <strong>to</strong> replace the<br />

guaranty. guaranty. material or <strong>to</strong> give a full refund for the full amount of the<br />

purchase price.<br />

8 Notification requirements Contact PRS immediately at (800) 727-9872 if roof leaks. Contact PRS immediately at (800) 727-9872 if roof leaks. None stated.<br />

9 Exclusive or additional PRS disclaims any warranty other than what is specifically PRS disclaims any warranty other than what is specifically Warranty is in lieu of all other warranties; PRS not liable for any<br />

remedy described in this guaranty. PRS shall not be liable for dam-ages described in this guaranty. PRS shall not be liable for dam-ages damages based upon negligence, breach of warranty, strict<br />

that are based upon negligence, breach of warranty, strict liability, that are based upon negligence, breach of warranty, strict liability, liability, or any other legal theory of liability other than exclusive<br />

or any other legal theory of liability other than the exclusive liability or any other legal theory of liability other than the exclusive liability liability set forth in warranty; excludes UCC warranties.<br />

set forth in the guaranty; excludes UCC warranties<br />

set forth in the guaranty; excludes UCC warranties<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (See Special Features/Conditions.) Neutral (See Special Features/Conditions.) Neutral (no provision)<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 17, 22, 24; also excludes 1, 2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 17, 22, 24; also excludes None listed; material-only warranty<br />

coverage (see Item 12 in damages resulting from vermin, etc. damages resulting from vermin, etc.<br />

Introduction)<br />

13 Wind coverage/exclusions No coverage for damage caused by wind. No coverage for damage caused by wind. No coverage for damage caused by wind.<br />

14 Specific conditions <strong>to</strong> make B, F, N; warranty indicates that lack of regular and routine B, F, N; warranty indicates that lack of regular and routine None listed.<br />

the warranty ineffective or maintenance may void contract. maintenance may void contract.<br />

null and void (see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain $7.50/square $6.00/square None<br />

794


16 Minimum charge $1,000 $750 None<br />

17 Ineligible structure or Condominiums or residential dwellings without prior PRS Condominiums or residential dwellings without prior PRS None<br />

building use approval; patios, promenades, parking roofs; partial roof approval; patios, promenades, parking roofs; partial roof<br />

applications, phase construction, heated tanks, silo facilities, applications, phase construction, heated tanks, silo facilities,<br />

freezer, and cold-s<strong>to</strong>rage facilities<br />

freezer, and cold-s<strong>to</strong>rage facilities<br />

18 Pre-construction notice and PRS requires a 14-day guaranty application notification in order <strong>to</strong> PRS requires a 14-day guaranty application notification in order <strong>to</strong> None required.<br />

approval requirements verify specifications and <strong>to</strong> assign a roof audi<strong>to</strong>r. verify specifications and <strong>to</strong> assign a roof audi<strong>to</strong>r.<br />

19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy PRS employee or an approved roof audi<strong>to</strong>r performs on-site PRS employee or an approved roof audi<strong>to</strong>r performs on-site No on-site inspections.<br />

inspections during application (depending on job size), after inspections during application (depending on job size), after<br />

completion, prior <strong>to</strong> issuance of guaranty, as well as two years completion, prior <strong>to</strong> issuance of guaranty, as well as two years<br />

after issuance of guaranty; no charge.<br />

after issuance of guaranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies None; material-only warranty<br />

obligation for two years. for two years.<br />

22 Backed by named insurance No; PRS indicates that it does not carry insurance covering its No; PRS indicates that it does not carry insurance covering its No; PRS indicates that it does not carry insurance covering its<br />

or surety warranty obligations. warranty obligations. warranty obligations.<br />

23 Issuing entity manufactures PRS manufactures and sells product PRS manufactures and sells product PRS manufactures and sells product.<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability No restrictions stated. No restrictions stated. No restrictions stated.<br />

26 Special features/condition Owner shall be invoiced for reasonable repair costs for repairs and a<br />

nominal inspection charge if leaks reported <strong>to</strong> PRS are a result of causes<br />

not covered by guaranty.<br />

In the event an emergency situation exists, owner may make necessary<br />

temporary repairs, either directly or by contacting the original roofing<br />

contrac<strong>to</strong>r. Upon investigation by a PRS representative, owner shall be<br />

reimbursed for reasonable emergency repair costs if the leak is the<br />

responsibility of PRS.<br />

In the event PRS must make repairs, owner is responsible for providing a<br />

clean roof surface such that repairs can be made. This shall include, but<br />

not be limited <strong>to</strong>, the removal of water, ice, snow, dirt, and debris, as well as<br />

pavers on inverted roof membrane systems, prior <strong>to</strong> permanent repairs<br />

being made.<br />

PRS' specifications and all details must be properly selected by an<br />

architect or an engineer <strong>to</strong> meet specific needs and the applicable design<br />

loads for each project. The issuance of this guaranty by PRS, the<br />

inspection of the system application (or any other parts of the roofing<br />

assembly), or any review of project specifications or plans, does not extend<br />

the terms and conditions of the guaranty and shall not constitute any<br />

substitution of professional judgment required in connection with the design<br />

of this project by the building owner or its design professional.<br />

Guaranty is not a maintenance agreement or an insurance policy; routine<br />

inspections and maintenance of the system must be completed by the<br />

building owner on a regular basis and is owner's responsibility.<br />

In the event PRS, the roofing contrac<strong>to</strong>r, and the owner cannot agree as<br />

<strong>to</strong> responsibilities under the guaranty, the parties agree <strong>to</strong> submit any such<br />

disagreement <strong>to</strong> arbitration as an exclusive remedy for resolution of such<br />

disagreement. All parties specifically waive any litigation alternative for<br />

resolution of any such dispute. (a) Any arbitration shall proceed in<br />

accordance with the directions of a professional roofing consultant mutually<br />

selected by the parties. In the event the parties cannot agree on an<br />

arbitra<strong>to</strong>r, each shall select an independent professional roofing consultant<br />

as their representative and these consultants shall, in turn, select another,<br />

unaffiliated professional roofing consultant who will serve as the arbitra<strong>to</strong>r.<br />

(b) All costs of any arbitra<strong>to</strong>r(s) shall be included in the final judgment of the<br />

arbitra<strong>to</strong>r. © Once a decision is reached by any arbitra<strong>to</strong>r, the prevailing<br />

party can pursue what-ever judicial action would be appropriate <strong>to</strong> enforce<br />

such decision.<br />

Owner shall be invoiced for reasonable repair costs for repairs and a nominal inspection<br />

charge if leaks reported <strong>to</strong> PRS are a result of causes not covered by guaranty.<br />

In the event an emergency situation exists, owner may<br />

make necessary temporary repairs, either directly or by contacting the original roofing<br />

contrac<strong>to</strong>r. Upon investigation by a PRS representative, owner shall be reimbursed for<br />

reasonable emergency repair costs if the leak is the responsibility of PRS.<br />

In the event PRS must make repairs, owner is responsible<br />

for providing a clean roof surface such that repairs can be made. This shall include, but not<br />

be limited <strong>to</strong>, the removal of water, ice, snow, dirt, and debris, as well as pavers on inverted<br />

roof membrane systems, prior <strong>to</strong> permanent repairs being made.<br />

PRS' specifications and all details must be properly selected by an architect or an engineer<br />

<strong>to</strong> meet specific needs and the applicable design loads for each project. The issuance of this<br />

guaranty by PRS, the inspection of the system application (or any other parts of the roofing<br />

assembly), or any review of project specifications or plans, does not extend the terms and<br />

conditions of the guaranty and shall not constitute any substitution of professional judgment<br />

required in connection with the design of this project by the building owner or its design<br />

professional.<br />

Guaranty is not a maintenance agreement or an insurance policy; routine inspections and<br />

maintenance of the system must be completed by the building owner on a regular basis and<br />

is owner's responsibility.<br />

In the event PRS, the roofing contrac<strong>to</strong>r, and the owner cannot agree as <strong>to</strong> responsibilities<br />

under the guaranty, the parties agree <strong>to</strong> submit any such disagreement <strong>to</strong> arbitration as an<br />

exclusive remedy for resolution of such disagreement. All parties specifically waive any<br />

litigation alternative for resolution of any such dispute. (a) Any arbitration shall proceed in<br />

accordance with the directions of a professional roofing consultant mutually selected by the<br />

parties. In the event the parties can-not agree on an arbitra<strong>to</strong>r, each shall select an<br />

independent professional roofing consultant as their representative and these consultants<br />

shall, in turn, select another, unaffiliated professional roofing consultant who will serve as the<br />

arbitra<strong>to</strong>r. (b) All costs of any arbitra<strong>to</strong>r(s) shall be included in the final judgment of the<br />

arbitra<strong>to</strong>r. © Once a decision is reached by any arbitra<strong>to</strong>r, the prevailing party can pursue<br />

whatever judicial action would be appropriate <strong>to</strong> enforce such decision.<br />

27 Executed by owner Yes; owner and roofing contrac<strong>to</strong>r must acknowledge and accept Yes; owner and roofing contrac<strong>to</strong>r must acknowledge and accept Yes; owner must execute and return <strong>to</strong> PRS the “Ten Year<br />

the guaranty by signing. the guaranty by signing. Limited Material Warranty” notification card.<br />

795


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Performance <strong>Roof</strong> Systems, Inc. (PRS) Protective Coatings, Inc. Republic Powdered Metals, Inc. (RPM)<br />

2 Title, original publication “Derbigum <strong>Roof</strong> Service Contract”; Oc<strong>to</strong>ber 1, 1993 "Protective Coatings, Inc. EPDM <strong>Roof</strong>ing Limited Year Warranty" "Republic Single Ply Systems Warranty"; September 1997;<br />

date, and identifying symbol, W001 9/97<br />

if any<br />

3 Product, specification, or Derbigum XPS, Derbigum XPS/FR, Derbicolor XPS, Derbicolor ProShield-Black, ProShield-White, ProShield-White Fire Geoflex PIB (Polyisobutylene) and Cooley C3 Single Ply<br />

system covered XPS/FR, Derbigum GP, Derbicolor GP, Derbigum GP/FR, Derbi- Retardant, Black Fire Retardant Totally Adhered, Plate Bonded, Systems<br />

color GP/FR, Derbibase<br />

NP Mechanically Attached, Ballasted<br />

4 Scope of coverage Material and workmanship; PRS guarantees that it will under-take Material and Workmanship; Protective Coatings warrants that the Material and workmanship; RPM warrants that the Republic<br />

all actions necessary <strong>to</strong> keep the PRS roof system in a watertight roofing membrane will be free from defects in workmanship and Single Ply System will remain free from leaks resulting from<br />

condition and will promptly repair deficiencies in the system's materials and, when properly installed, will remain watertight. defects in the manufacture of the materials or the improper<br />

condition that could endanger the membrane's ability <strong>to</strong> remain<br />

installation thereof and that, should a leak occur in any area of<br />

watertight provided that such actions and repairs are a result of<br />

the Republic Single Ply System, RPM will promptly correct such<br />

improper installation of the system, membrane performance, or<br />

leak at its own expense. Republic Single Ply System shall<br />

ordinary wear and tear by the elements. The roof system only<br />

mean all integral field sheet and accessory materials<br />

covers materials PRS sells or approves, other than metal.<br />

manufactured and/or supplied by Republic.<br />

Building owner is responsible for any costs <strong>to</strong> repair any building<br />

component other than the system if leaks occur. The system<br />

consists of all roof components from the roof membrane <strong>to</strong> the<br />

roof deck, including approved base and ply sheets; all adhesives,<br />

insulations, and fasteners; but excluding roof decks and coatings<br />

or surfacing not fac<strong>to</strong>ry applied.<br />

5 Length of coverage 10 years 5, 10, 15 or 20 years 10, 15 or 20 years<br />

6 Nature of remedy PRS' exclusive responsibility and liability is <strong>to</strong> make repairs that may be Protective Coatings will supply replacement material at no cost <strong>to</strong> RPM warrants that it will promptly correct leaks in any area of<br />

necessary <strong>to</strong> maintain the roofing system in a watertight condition. PRS' the owner. the Republic Single Ply System at its own expense.<br />

liability is limited <strong>to</strong> the repair or replacement of any portion of the system<br />

damaged by leaks that are a result of covered<br />

7 Monetary limitations No limit <strong>to</strong> PRS' expenditures for damages covered by this None stated None stated.<br />

guaranty.<br />

8 Notification requirements Contact PRS immediately at (800) 727-9872 if roof leaks. Written notice by registered mail <strong>to</strong> Protective Coatings' Fort Building owner must notify RPM immediately upon the discovery<br />

Wayne, IN, office within 30 days of discovery of any defect or leak. of any leaks in the Republic Single Ply System and confirm<br />

notification in writing within seven days after such discovery.<br />

9 Exclusive or additional PRS disclaims any warranty other than what is specifically Owner's sole and exclusive remedy; no other warranties; excludes Remedy in the warranty is the sole and exclusive remedy available <strong>to</strong> the<br />

remedy described in this guaranty. PRS shall not be liable for dam-ages UCC warranties. building owner so that RPM's repair constitutes fulfillment of all<br />

that are based upon negligence, breach of warranty, strict liability,<br />

obligations. Warranty is in lieu of any other guarantees or warranties,<br />

or any other legal theory of liability other than the exclusive liability<br />

express or implied; no representative, employee, or agent of RPM or any<br />

set forth in the guaranty; excludes UCC warranties<br />

other person has any authority <strong>to</strong> modify or enlarge the scope of the<br />

warranty or <strong>to</strong> assume for RPM any additional or other liability in<br />

connection with Republic Single Ply System; excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (See Special Features/Conditions.) Neutral (no provision) Neutral (no provision)<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13, 17, 22, 24; also excludes 1, 2, 3, 4, 5, 6, 9, 10, 12, 13 1, 3, 5, 6, 7, 10, 11, 12, 15, 16, 17, 22, 23<br />

coverage (see Item 12 in damages resulting from vermin, etc.<br />

Introduction)<br />

13 Wind coverage/exclusions No coverage for damage caused by wind. Warranty excludes damage caused by wind. Warranty excludes hurricanes and <strong>to</strong>rnadoes. RPM indicates<br />

that warranty covers roof damage resulting from wind speeds up<br />

<strong>to</strong> 73 mph.<br />

14 Specific conditions <strong>to</strong> make B, F, N; warranty indicates that lack of regular and routine C A, B, C, F, G, H, I, J, L, M (See Special Features/ Conditions)<br />

the warranty ineffective or maintenance may void contract.<br />

null & void (see Item 14<br />

Introduction)<br />

796


15 Cost <strong>to</strong> obtain $12.50/square 5 year: none; 10 year: $3.00/square 10 years: $5.00/sq; 15 years: $10.00/sq; 20 years: $20.00/sq<br />

15 yrs: $5.00/sq 20 yrs: $8.00/sq<br />

16 Minimum charge $1,250 5 year: none; 10 year: $300 10 years: $500; 15 years: $1,000; 20 years: $2,000<br />

15 yrs: $500 20 yrs: $800<br />

17 Ineligible structure or Condominiums or residential dwellings without prior PRS Noncommercial installations None<br />

building use<br />

approval; patios, promenades, parking roofs; partial roof<br />

applications, phase construction, heated tanks, silo facilities,<br />

freezer, and cold-s<strong>to</strong>rage facilities<br />

18 Pre-construction notice and PRS requires a 14-day guaranty application notification in order <strong>to</strong> A pre-installation notice form must be submitted and approved in Notice of award from contrac<strong>to</strong>r detailing job requirements must<br />

approval requirements verify specifications and <strong>to</strong> assign a roof audi<strong>to</strong>r. writing 14 days prior <strong>to</strong> start. be approved by RPM prior <strong>to</strong> construction.<br />

19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy PRS employee or an approved roof audi<strong>to</strong>r performs on-site Protective Coatings' representative makes on-site inspection upon RPM technical service representative makes on-site inspections<br />

inspections during application (depending on job size), after completion of application; no charge. prior <strong>to</strong>, during application and upon completion, prior <strong>to</strong><br />

completion, prior <strong>to</strong> issuance of guaranty, as well as two years<br />

issuance of warranty; no charge.<br />

after issuance of guaranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs due <strong>to</strong> workmanship Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> leaks and workmanship<br />

obligation for two years. deficiencies for two years. deficiencies for two years.<br />

22 Backed by named insurance No; PRS indicates that it does not carry insurance covering its No; Protective Coatings indicates that it carries $500,000 general No; RPM indicates that it does not carry insurance covering its<br />

or surety warranty obligations. liability insurance. warranty obligations.<br />

23 Issuing entity manufactures PRS manufactures and sells product Protective Coatings, Inc. manufactures and sells product. RPM manufactures and sells the materials<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision. No renewal extension.<br />

extension<br />

25 Assignability No restrictions stated. Not assignable, but if the original owner is the developer or builder of the<br />

building, he may, within one year of completion of construction, request<br />

Protective Coatings, Inc. permit an assignment of the warranty <strong>to</strong> the<br />

purchase of the building from owner.<br />

Warranty is non-transferable.<br />

26 Special features/condition Owner shall be invoiced for reasonable repair costs for re-pairs and a nominal inspection No representative has authority <strong>to</strong> make any representations other Owner agrees <strong>to</strong> accept RPM warranty as part of its purchase of<br />

than stated in the warranty.<br />

charge if leaks reported <strong>to</strong> PRS are a result of causes not covered by guaranty.<br />

In the event an emergency situation exists, owner may make necessary temporary repairs,<br />

either directly or by contacting the original roofing contrac<strong>to</strong>r. Upon investigation by a PRS<br />

representative, owner shall be reimbursed for reasonable emergency repair costs if the leak<br />

is the responsibility of PRS.<br />

In the event PRS must make repairs, owner is responsible for providing a clean roof<br />

surface such that repairs can be made. This shall include, but not be limited <strong>to</strong>, the removal<br />

of water, ice, snow, dirt, and debris, as well as pavers on inverted roof membrane systems,<br />

prior <strong>to</strong> permanent repairs being made.<br />

PRS' specifications and all details must be properly selected by an architect or an engineer<br />

<strong>to</strong> meet specific needs and the applicable design loads for each project. The issuance of this<br />

guaranty by PRS, the inspection of the system application (or any other parts of the roofing<br />

assembly), or any review of project specifications or plans, does not extend the terms and<br />

conditions of the guaranty and shall not constitute any substitution of professional judgment<br />

required in connection with the design of this project by the building owner or its design<br />

professional.<br />

Contract is not a maintenance agreement or an insurance policy; routine inspections and<br />

maintenance of the system must be completed by the building owner on a regular basis and<br />

is owner's responsibility.<br />

In the event PRS, the roofing contrac<strong>to</strong>r, and the owner cannot agree as <strong>to</strong> responsibilities<br />

under the guaranty, the parties agree <strong>to</strong> submit any such disagreement <strong>to</strong> arbitration as an<br />

exclusive remedy for resolution of such disagreement. All parties specifically waive any<br />

litigation alternative for resolution of any such dispute. (a) Any arbitration shall proceed in<br />

accordance with the directions of a professional roofing consultant mutually selected by the<br />

parties. In the event the parties cannot agree on an arbitra<strong>to</strong>r, each shall select an<br />

independent professional roofing consultant as their representative and these consultants<br />

shall, in turn, select another, unaffiliated professional roofing consultant who will serve as the<br />

arbitra<strong>to</strong>r. (b) All costs of any arbitra<strong>to</strong>r(s) shall be included in the final judgment of the<br />

arbitra<strong>to</strong>r. © Once a decision is reached by any arbitra<strong>to</strong>r, the prevailing party can pursue<br />

what-ever judicial action would be appropriate <strong>to</strong> enforce such decision.<br />

27 Executed by owner Yes; owner and roofing contrac<strong>to</strong>r must acknowledge and accept Yes See Special Features above.<br />

the guaranty by signing.<br />

the Republic Single Ply System and understands that the liability<br />

of RPM relating <strong>to</strong> the Republic Single Ply System and its<br />

installation is limited <strong>to</strong> the obligation <strong>to</strong> address warranty<br />

concerns.<br />

Owner understands and agrees that the construction and<br />

interpretation of the warranty shall be governed by the laws of<br />

the State of Ohio, excluding principles of conflicts of law.<br />

Owner agrees <strong>to</strong> follow and be bound by all terms and<br />

conditions stated in the Republic Care and Maintenance Guide<br />

which is incorporated in<strong>to</strong> the warranty by reference.<br />

797


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Republic Powdered Metals, Inc. (RPM) <strong>Roof</strong>ing Products International Inc. (RPI) <strong>Roof</strong>ing Products International Inc. (RPI)<br />

2 Title, original publication Manufacturer's Limited Warranty Material Only"; September “Limited Membrane Only Warranty”; RPI-54-692-5C “Limited Warranty Form”; Form RPI-91-31-1M<br />

date, and identifying symbol, 1997; W004 9/97<br />

if any<br />

3 Product, specification, or Geoflex, Cooley C3, RPI EPDM .045 Black, .060 Black, .045 White, .060 White, RPI RPI EPDM .045 Black, .060 Black, .045 White, .060 White, RPI<br />

system covered FR (Fire Retardant) EPDM .045 Black, .060 Black, .045 White, FR (Fire Retardant) EPDM .045 Black, .060 Black, .045 White.<br />

.060 White.<br />

4 Scope of coverage Material only; RPM warrants that the Republic product(s) were Material only; RPI warrants that the non-reinforced rubber Material and workmanship; RPI warrants <strong>to</strong> repair any leaks due<br />

manufactured in accordance with RPM's specifications and, membrane sold as "First Grade" will be free from defects in <strong>to</strong> defects in the RPI <strong>Roof</strong>ing System materials or in<br />

when applied <strong>to</strong> smooth, dry compatible surfaces in material and workmanship at time of installation and will not workmanship of the RPI-registered roofing applica<strong>to</strong>r.<br />

accordance with RPM's application instructions and<br />

prematurely deteriorate <strong>to</strong> the point of failure because of<br />

specifications, will remain free of voids, cracking and/or weathering if properly installed, maintained, and used for purpose<br />

crazing as a result of defects in the material.<br />

seller intended. This warranty refers <strong>to</strong> the membrane material<br />

only. Flashings, adhesives, and other accessories contained in a<br />

membrane system are not covered by warranty.<br />

5 Length of coverage 5, 10 or 15 years (RPM indicates that warranty coverage 10 or 20 years 5, 10, or 15 years<br />

depends upon specification and substrate used.)<br />

6 Nature of remedy Should RPM's product(s) fail <strong>to</strong> conform <strong>to</strong> warranty, RPM If membrane proves <strong>to</strong> be defective in materials or workmanship, RPI will repair leaks in the RPI Rubber <strong>Roof</strong>ing System.<br />

shall, at its option, supply a sufficient quantity of materials seller's liability and buyer's remedies limited <strong>to</strong> repair and<br />

necessary <strong>to</strong> remedy the defects, or the cash equivalent of replacement of the defective membrane at the FOB point in the<br />

same<br />

original contract. If membrane shows premature deterioration<br />

because of weathering, seller's liability and buyer's remedies are<br />

limited, at seller's option, <strong>to</strong> providing repair material for the<br />

original membrane or credit <strong>to</strong> be applied <strong>to</strong>ward purchase of new<br />

membrane.<br />

7 Monetary limitations RPM's <strong>to</strong>tal obligation over the life of the warranty shall not Value of remedy <strong>to</strong> be determined by seller based on number of RPI's obligation <strong>to</strong> remedy defects shall not exceed owner's<br />

exceed the building owner's original cost of the RPM supplied remaining months of the unexpired warranty, prorated at the original cost of materials and labor for installation of the RPI<br />

product(s). current prices for the membrane. Maximum prorated value allowed roofing system.<br />

for repair or credit not <strong>to</strong> exceed original membrane purchase<br />

price.<br />

8 Notification requirements None Notification of breach of warranty within 30 days of discovery of Written notification within 30 days of discovery of any leaks, by<br />

premature deterioration of membrane<br />

certified mail, return receipt requested, <strong>to</strong> RPI at 57460 Dewitt<br />

St., Elkhart, IN 46517-1018, or other such address RPI notifies<br />

owner.<br />

9 Exclusive or additional Remedy in warranty is the sole and exclusive remedy No warranties that extend beyond what is stated on warranty Warranty is in lieu of any and all other express warranties that<br />

remedy available <strong>to</strong> the building owner so that RPM's compliance document; excludes UCC warranties. are in conflict; no warranties that extend beyond what is stated<br />

constitutes fulfillment of all obligations. Warranty is in lieu of<br />

on warranty document.<br />

all other warranties, express or implied. No representative,<br />

employee, or agent of RPM or any other person has any<br />

authority <strong>to</strong> modify or enlarge the scope of the warranty or <strong>to</strong><br />

assume for RPM any additional or other liability in connection<br />

with the product; excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (no provision). Unclear; warranty states, “If upon inspection by the Seller, the Neutral (no provision).<br />

applicability<br />

Membrane proves <strong>to</strong> be defective.....”<br />

12 Specific exclusions from 1, 2, 3, 6, 7, 10, 11, 12, 16, 17, 19, 20, 23 12, 19 1, 3, 4, 6, 7, 11, 12, 16, 17, 18, 22. Warranty also states that<br />

coverage (see Item 12 in<br />

RPI shall have no obligation if leaks or damages are caused by<br />

Introduction)<br />

failure of owner <strong>to</strong> comply with every condition, exclusion, or<br />

limitation in the warranty document.<br />

798


13 Wind coverage/exclusions Warranty excludes gales, hurricanes and <strong>to</strong>rnadoes. RPI indicates that there is no coverage for damage caused by RPI indicates that warranty covers roof damage resulting<br />

wind.<br />

from wind speeds up <strong>to</strong> 39 mph. Warranty excludes gales,<br />

hurricanes, and <strong>to</strong>rnadoes.<br />

14 Specific conditions <strong>to</strong> make<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

C, R None listed C<br />

15 Cost <strong>to</strong> obtain None None Call RPI 800/628-2957<br />

16 Minimum charge None None Call RPI 800/628-2957<br />

17 Ineligible structure or<br />

building use<br />

18 Pre-construction notice and<br />

approval requirements<br />

19 Approved, authorized, or<br />

licensed requirements<br />

None None Buildings not used for commercial purposes, including<br />

buildings used for residential, personal, family or household<br />

purposes; cold-s<strong>to</strong>rage buildings not approved prior <strong>to</strong><br />

application; mechanically attached roofs on buildings more<br />

than four s<strong>to</strong>ries high.<br />

RPM requires a Notice of Award on all projects showing None Submittal of job start notification form, W-3, <strong>to</strong> RPI<br />

pertinent information.<br />

headquarters office for review by technical representative<br />

prior <strong>to</strong> job start.<br />

Yes No Yes<br />

20 Job inspection policy No on-site inspections No on-site inspections RPI technical representative makes on-site inspection after<br />

application, prior <strong>to</strong> issuance of warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation<br />

obligation<br />

22 Backed by named insurance<br />

or surety<br />

23 Issuing entity manufactures<br />

and/or sells products<br />

24 Conditions for renewal or<br />

extension<br />

None; material-only warranty. None; material-only warranty. Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

deficiencies for two years.<br />

No; RPM indicates that it does not carry insurance covering its No; RPI indicates that it does not carry insurance covering its No; RPI does not carry insurance covering its warranty<br />

warranty obligations. warranty obligations. obligations.<br />

RPM manufactures and sells the product RPI sells product only RPI sells product only<br />

No renewal provision. No renewal provision. No renewal provision.<br />

25 Assignability Warranty is non-transferable. No restrictions stated. No restrictions stated.<br />

26 Special features/condition The owner understands and agrees that the construction and Warranty states that no representative of RPI has authority <strong>to</strong> No representative of RPI or any other person or entity has<br />

interpretation of the warranty shall be governed by the laws of make any representations or promises except as stated in the the authority <strong>to</strong> make any representations or promises<br />

the State of Ohio, excluding principles of conflicts of law. warranty document itself. except as stated in warranty document.<br />

27 Executed by owner No No No<br />

799


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Sarnafil, Inc. Sarnafil, Inc. Seaman Corporation<br />

2 Title, original publication “10 Year Standard Warranty - Sarnafil <strong>Roof</strong>ing Warranty for “10 Year System Warranty – Sarnafil <strong>Roof</strong>ing Warranty for “Materials Warranty for FiberTite <strong>Roof</strong>ing Membrane”<br />

date, and identifying symbol, Commercial Building”; March 1995 Commercial Building;” March 1995<br />

if any<br />

3 Product, specification, or Sarnafil G410, S327, G476 Sarnafil G410, S327, G476 FiberTite Single-Ply <strong>Roof</strong><br />

system covered<br />

4 Scope of coverage Material and workmanship; Sarnafil warrants that it will repair Material and workmanship; Sarnafil warrants that it will repair Seaman warrants its FiberTite membrane materials <strong>to</strong> be in<br />

leaks originating from the Sarnafil roofing membrane or Sarnafil leaks originating from the Sarnafil roofing membrane, Sarna- accordance with its published specifications and free from<br />

roofing accessories or a defect in the Sarnafil authorized therm insulation, Sarnafil roofing accessories, or a defect in material defects in components and workmanship that<br />

applica<strong>to</strong>r's workmanship applied <strong>to</strong> the Sarnafil membrane. the Sarnafil authorized applica<strong>to</strong>r's workmanship applied <strong>to</strong> would affect performance.<br />

the Saranfil membrane.<br />

5 Length of coverage 10 years 10 years 10 years<br />

6 Nature of remedy Sarnafil's liability limited <strong>to</strong> Sarnafil's repair of roofing membrane Sarnafil's liability is limited <strong>to</strong> repair of Sarnafil's roofing Seaman's obligation is limited <strong>to</strong>, at its option, allowance for<br />

or accessory. membrane, Sarnatherm insulation, or accessory. credit, repair, or replacement of any material that may prove<br />

defective under normal use and service. Seaman's liability<br />

is prorated such that Seaman's liability ranges from 100<br />

percent if the defect occurs in the first year <strong>to</strong> 8 percent if<br />

the defect occurs in the tenth year.<br />

7 Monetary limitations None stated. None stated. Seaman's prorated liability is based upon the original sales<br />

price.<br />

8 Notification requirements Written notification <strong>to</strong> Sarnafil, Can<strong>to</strong>n Commerce Center, Can<strong>to</strong>n, Written notification <strong>to</strong> Sarnafil, Can<strong>to</strong>n Commerce Center, Written notification within 30 days of discovery of the<br />

MA, within 30 days of discovery of each leak in the roofing system. Can<strong>to</strong>n, MA, within 30 days of discovery of each leak in the alleged defect <strong>to</strong> Seaman Corporation.<br />

roofing system.<br />

9 Exclusive or additional Warranty is given in lieu of all other warranties; remedies stated in Warranty is given in lieu of all other warranties; remedies No other warranties applicable <strong>to</strong> material; corrections <strong>to</strong><br />

remedy warranty are exclusive; seeks <strong>to</strong> exclude UCC stated in warranty are exclusive; seeks <strong>to</strong> exclude UCC non-conformities and defects as provided for in the warranty<br />

warranties.<br />

shall constitute fulfillment of all liabilities of Seaman <strong>to</strong> the<br />

cus<strong>to</strong>mer, whether based on contract, negligence, or<br />

otherwise. Should the fabric prove defective <strong>to</strong> the extent<br />

that it precludes the remedying of warranted defects by<br />

repair or replacement, cus<strong>to</strong>mer's sole and exclusive<br />

remedy shall be the refund of the purchase price of the<br />

fabric or the part thereof that is defective, upon its return <strong>to</strong><br />

Seaman Corporation. No warranties or representations at<br />

any time by any sales representative, dealer, agent, or any<br />

person shall be effective <strong>to</strong> vary or expand the warranty;<br />

excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Sarnafil's determination Sarnafil's determination Seaman's determination.<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 6, 7, 8, 12, 17, 23. <strong>Roof</strong>ing damage by wind-blown objects 1, 2, 3, 6, 7, 8, 12, 17, 23. <strong>Roof</strong>ing damage by wind-blown 1, 3, 13, 16, 18, 20, 21, 23<br />

coverage (see Item 12 in is also specifically excluded. objects is also specifically excluded.<br />

Introduction)<br />

13 Wind coverage/exclusions Sarnafil indicates that warranty covers roof damage resulting from Sarnafil indicates that warranty covers roof damage resulting Warranty excludes hurricanes and <strong>to</strong>rnadoes. Seaman<br />

wind speeds up <strong>to</strong> 60 mph. Warranty excludes winds<strong>to</strong>rms in from wind speeds up <strong>to</strong> 60 mph. Warranty excludes indicates that warranty covers roof damage resulting from<br />

excess of 60 mph, hurricanes, and <strong>to</strong>rnadoes. winds<strong>to</strong>rms in excess of 60 mph, hurricanes, and <strong>to</strong>rnadoes. wind speeds up <strong>to</strong> 73 mph.<br />

800


14 Specific conditions <strong>to</strong> C, G C, G B, C<br />

make the warranty<br />

ineffective or null and void<br />

(see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain $6.00/square $6.00/square $9.00/square<br />

16 Minimum charge $800 $800 $900<br />

17 Ineligible structure or Private residences Private residences <strong>Roof</strong>ing installations for personal, family, or household<br />

building use<br />

purposes.<br />

18 Pre-construction notice Contrac<strong>to</strong>r is <strong>to</strong> submit a Sarnafil “notice of award” form <strong>to</strong> Contrac<strong>to</strong>r is <strong>to</strong> submit a Sarnafil “notice of award” form <strong>to</strong> Contrac<strong>to</strong>r must submit FiberTite “request for warranty<br />

and approval requirements Sarnafil's technical department for review and acceptance prior <strong>to</strong> Sarnafil's technical department for review and acceptance form/roof award information material submittal data” and<br />

shipment of Sarnafil membrane and accessories. prior <strong>to</strong> shipment of Sarnafil membrane and accessories. obtain approval before material can be shipped.<br />

19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy Sarnafil field technical representatives make on-site inspections Sarnafil field technical representatives make on-site Seaman technical service representatives make on-site<br />

during application (determined by field representative schedule) inspections during application (determined by field inspections prior <strong>to</strong>, during (interim inspections coordinated<br />

and after completion, as well as two years after issuance of representative schedule) and after completion, as well as two with representative's travel schedule), and after completion,<br />

warranty; no charge. years after issuance of warranty; no charge. prior <strong>to</strong> issuance of warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post- The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

installation obligation deficiencies for two years. deficiencies for two years. deficiencies for two years.<br />

22 Backed by named No; Sarnafil indicates that it does not carry insurance covering its No; Sarnafil indicates that it does not carry insurance covering No; Seaman indicates that it is self-insured.<br />

insurance or surety warranty obligations. its warranty obligations.<br />

23 Issuing entity Sarnafil manufactures and sells the product. Sarnafil manufactures and sells the product. Seaman manufactures and sells the product.<br />

manufactures and/or sells<br />

products<br />

24 Conditions for renewal or No renewal provision. No renewal provision. No renewal provision.<br />

extension<br />

25 Assignability The warranty is extended solely and exclusively <strong>to</strong> the owner of The warranty is extended solely and exclusively <strong>to</strong> the owner Warranty may be assignable <strong>to</strong> a subsequent owner, only if<br />

the building at the time the roofing membrane is installed and is of the building at the time the roofing membrane is installed the original owner requests in writing that Seaman<br />

not assignable or transferable unless approved in advance and in and is not assignable or transferable unless approved in Corporation consent <strong>to</strong> an assignment <strong>to</strong> the purchaser of<br />

writing by Sarnafil and the costs <strong>to</strong> process the transfer and <strong>to</strong> advance and in writing by Sarnafil and the costs <strong>to</strong> process the the building, which consent will not be unreasonably<br />

inspect and repair the roof, if necessary, are paid for by the transfer and <strong>to</strong> inspect and repair the roof, if necessary, are withheld.<br />

original owner.<br />

paid for by the original owner.<br />

26 Special features/condition Should the roofing membrane be concealed, the cost of exposure Should the roofing membrane be concealed, the cost of The owner will be responsible for the cost of investigation if<br />

of the roofing membrane for purposes of Sarnafil's investigation exposure of the roofing membrane for purposes of Sarnafil's any leak is determined not <strong>to</strong> be covered by warranty<br />

and/or repair, such as removal and replacement of any paving or investigation and/or repair, such as removal and replacement<br />

overburden, shall be the owner's responsibility.<br />

of any paving or overburden, shall be the owner's responsibility.<br />

Any controversy or claim arising out of or relating <strong>to</strong> the warranty<br />

shall be settled by arbitration in Bos<strong>to</strong>n, Mass. by the American Any controversy or claim arising out of or relating <strong>to</strong> the<br />

Arbitration <strong>Association</strong> in accordance with the Construction warranty shall be settled by arbitration in Bos<strong>to</strong>n, Mass. by the<br />

Industry Arbitration Rules, and judgment upon the arbitration American Arbitration <strong>Association</strong> in accordance with the<br />

award may be entered in any court having jurisdiction thereof. No Construction Industry Arbitration Rules, and judgment upon<br />

representative of Sarnafil has authority <strong>to</strong> make any<br />

the arbitration award may be entered in any court having<br />

representations or promises except as stated in the warranty. jurisdiction thereof. No representative of Sarnafil has authority<br />

<strong>to</strong> make any representations or promises except as stated in<br />

the warranty.<br />

27 Executed by owner Yes Yes Yes<br />

801


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Seaman Corporation Seaman Corporation Seaman Corporation<br />

2 Title, original publication “Warranty for Commercial <strong>Roof</strong>ing” “Materials Warranty for FiberTite <strong>Roof</strong>ing Membrane” “Warranty for Commercial <strong>Roof</strong>ing”<br />

date, and identifying symbol,<br />

if any<br />

3 Product, specification, or FiberTite <strong>Roof</strong>ing Systems FiberTite <strong>Roof</strong>ing Systems FiberTite Single-Ply <strong>Roof</strong><br />

system covered<br />

4 Scope of coverage Material and workmanship; Seaman warrants that it will repair Seaman warrants its FiberTite membrane materials <strong>to</strong> be in Material and workmanship; Seaman warrants that it will<br />

leaks in the FiberTite roofing system and/or defective accordance with its published specifications and free from repair leaks in the FiberTite roofing system and/or defective<br />

workmanship provided by Seaman or its authorized FiberTite material defects in components and workmanship that would workmanship provided by Seaman or its authorized<br />

single-ply roof applica<strong>to</strong>r. affect performance. FiberTite single-ply roof applica<strong>to</strong>r.<br />

5 Length of coverage 5 or 10 years 15 years 15 years<br />

6 Nature of remedy Seaman will repair leaks at its expense. Seaman's obligation is limited <strong>to</strong>, at its option, allowance for Seaman will repair leaks at its expense.<br />

credit, repair, or replacement of any material that may prove<br />

defective under normal use and service. Seaman's liability is<br />

prorated such that Seaman's liability ranges from 100 percent<br />

if the defect occurs in the first year <strong>to</strong> 5 percent if the defect<br />

occurs in the fifteenth year.<br />

7 Monetary limitations Seaman's obligation over the lifetime of warranty shall not Seaman's prorated liability is based upon the original sales Seaman's obligation over the lifetime of warranty shall not<br />

exceed the original cost of the installed roof. price. exceed the original cost of the installed roof.<br />

8 Notification requirements Written notice <strong>to</strong> Seaman Corporation, 1000 Venture Blvd., Written notification within 30 days of discovery of the alleged Written notice <strong>to</strong> Seaman Corporation, 1000 Venture Blvd.,<br />

Wooster, OH 44691, within 30 days after discovery of any defect <strong>to</strong> Seaman Corporation. Wooster, OH 44691, within 30 days after discovery of any<br />

leaks in the roofing system.<br />

leaks in the roofing system.<br />

9 Exclusive or additional The owner's sole and exclusive remedy for failure of the No other warranties applicable <strong>to</strong> material; corrections <strong>to</strong> non- The owner's sole and exclusive remedy for failure of the<br />

remedy roofing system; no employee or representative has authority <strong>to</strong> conformities and defects as provided for in the warranty shall roofing system; no employee or representative has authority<br />

make any representations other than those stated in warranty; constitute fulfillment of all liabilities of Seaman <strong>to</strong> the <strong>to</strong> make any representations other than those stated in<br />

excludes UCC warranties. cus<strong>to</strong>mer, whether based on contract, negligence, or warranty; excludes UCC warranties.<br />

otherwise. Should the fabric prove defective <strong>to</strong> the extent that<br />

it precludes the remedying of warranted defects by repair or<br />

replacement, cus<strong>to</strong>mer's sole and exclusive remedy shall be<br />

the refund of the purchase price of the fabric or the part<br />

thereof that is defective, upon its return <strong>to</strong> Seaman<br />

Corporation. No warranties or representations at any time by<br />

any sales representative, dealer, agent, or any person shall be<br />

effective <strong>to</strong> vary or expand the warranty; excludes UCC<br />

warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Seaman's good faith determination. Seaman's determination. Seaman's good faith determination.<br />

applicability<br />

12 Specific exclusions from 1, 3, 4, 5, 6, 7, 9, 10, 12, 18, 22, 24 1, 3, 13, 16, 18, 20, 21, 23 1, 3, 4, 5, 6, 7, 9, 10, 12, 18, 22, 24<br />

coverage (see Item 12 in<br />

Introduction)<br />

13 Wind coverage/exclusions Warranty excludes hurricanes and <strong>to</strong>rnadoes. Seaman Warranty excludes hurricanes and <strong>to</strong>rnadoes. Seaman Warranty excludes hurricanes and <strong>to</strong>rnadoes. Seaman<br />

indicates that warranty covers roof damage resulting from indicates that warranty covers roof damage resulting from indicates that warranty covers roof damage resulting from<br />

wind speeds up <strong>to</strong> 73 mph. wind speeds up <strong>to</strong> 73 mph. wind speeds up <strong>to</strong> 73 mph.<br />

802


14 Specific conditions <strong>to</strong> make<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

B, C, F, G, I, J, M, N; the warranty also states that Seal-Dry A, H. Warranty will also be void if any of the specific A, H. Warranty will also be void if any of the specific<br />

has no obligation under warranty unless Seal-Dry agents or exclusions listed above occur or if material is exposed <strong>to</strong> exclusions listed above occur or if material is exposed <strong>to</strong><br />

authorized installers are allowed access <strong>to</strong> roof <strong>to</strong> make "excessive pressures or sources," external forces, radiation, “excessive pressures or sources,” external forces, radiation,<br />

inspections and repairs during regular working hours. harmful fumes or foreign substances in the atmosphere, or harmful fumes or foreign substances in the atmosphere, or<br />

any use not specifically for roofing application<br />

any use not specifically for roofing application.<br />

15 Cost <strong>to</strong> obtain $6.00/square $2.00/square None<br />

16 Minimum charge $650 $250 None<br />

17 Ineligible structure or<br />

building use<br />

18 Pre-construction notice and<br />

approval requirements<br />

19 Approved, authorized, or<br />

licensed requirements<br />

Residential single-dwelling homes eligible for membrane only <strong>Roof</strong>ing installations for personal, family, or household <strong>Roof</strong>ing installations for personal, family, or household<br />

warranty. purposes. purposes.<br />

The contrac<strong>to</strong>r <strong>to</strong> provide pre-installation notice with building Contrac<strong>to</strong>r must submit FiberTite “request for warranty Contrac<strong>to</strong>r must submit FiberTite “request for warranty<br />

and job requirements and obtain approval prior <strong>to</strong> beginning form/roof award information material submittal data” and form/roof award information material submittal data” and<br />

installation. obtain approval before material can be shipped. obtain approval before material can be shipped.<br />

Yes Yes Yes<br />

20 Job inspection policy Seaman technical service representatives make on-site Seaman technical service representatives make on-site Seaman technical service representatives make on-site<br />

inspections prior <strong>to</strong>, during (interim inspections coordinated inspections prior <strong>to</strong>, during (interim inspections coordinated inspections prior <strong>to</strong>, during (interim inspections coordinated<br />

with representative's travel schedule), and after completion, with representative's travel schedule), and after completion, with representative's travel schedule), and after completion,<br />

prior <strong>to</strong> issuance of warranty; no charge. prior <strong>to</strong> issuance of warranty; no charge. prior <strong>to</strong> issuance of warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation<br />

obligation<br />

22 Backed by named insurance<br />

or surety<br />

23 Issuing entity manufactures<br />

and/or sells products<br />

24 Conditions for renewal or<br />

extension<br />

No Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

deficiencies for two years.<br />

deficiencies for two years.<br />

No; Seaman indicates that it is self-insured No; Seaman indicates that it is self-insured No; Seaman indicates that it is self-insured<br />

Seaman manufactures and sells the product. Seaman manufactures and sells the product. Seaman manufactures and sells the product.<br />

No renewal provision No renewal provision No renewal provision<br />

25 Assignability No restrictions stated. No restrictions stated. No restrictions stated.<br />

26 Special features/condition All purchase orders for FiberTite Membrane will be deemed All purchase orders for FiberTite Membrane will be deemed All purchase orders for FiberTite Membrane will be deemed<br />

submitted subject <strong>to</strong> and in accordance with Seaman submitted subject <strong>to</strong> and in accordance with Seaman submitted subject <strong>to</strong> and in accordance with Seaman<br />

Corporation standard terms and conditions of sale. Corporation standard terms and conditions of sale. Corporation standard terms and conditions of sale.<br />

27 Executed by owner No No No<br />

803


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Seaman Corporation Siplast, Inc. Siplast, Inc.<br />

2 Title, original publication “Warranty for Commercial <strong>Roof</strong>ing” Siplast, Inc. “<strong>Roof</strong> Membrane Limited Warranty”; Oc<strong>to</strong>ber 15, Siplast, Inc. “<strong>Roof</strong> Membrane Guarantee” March 1, 1982<br />

date, and identifying symbol, 1987<br />

if any<br />

3 Product, specification, or FiberTite Single-Ply <strong>Roof</strong> Paratech Paradiene 20/30, Veral, Paradiene 40, Parafor 50 LT<br />

system covered<br />

4 Scope of coverage Material and workmanship; Seaman warrants that it will repair Siplast warrants that the roof membrane shall remain in Siplast guarantees roof membrane shall remain in watertight<br />

leaks in the FiberTite roofing system and/or defective watertight condition if roof membrane is installed according <strong>to</strong> condition if roof membrane is installed according <strong>to</strong> Siplast<br />

workmanship provided by Seaman or its authorized FiberTite Siplast specifications by an approved roofing contrac<strong>to</strong>r and specifications by an approved roofing contrac<strong>to</strong>r and the<br />

single-ply roof applica<strong>to</strong>r. the use of Siplast materials has been approved in advance; use of Siplast materials has been approved in advance;<br />

unclear from the document itself whether warranty covers unclear from the document itself whether guarantee covers<br />

workmanship. Siplast indicates that the workmanship of the workmanship. [Siplast indicates that the workmanship of the<br />

contrac<strong>to</strong>r is covered.<br />

contrac<strong>to</strong>r is covered.]<br />

5 Length of coverage 15 years 5 or 10 years 10 years, with additional 5-year and 10-year extension<br />

options available<br />

6 Nature of remedy Seaman will repair leaks at its expense. Siplast shall repair the roof membrane at its own expense. Siplast shall repair the roof membrane at its own expense.<br />

(See Special Features/Conditions.)<br />

(See Special Features/Conditions.)<br />

7 Monetary limitations None stated. Siplast's liability for the cost of repairs shall not exceed in the None stated.<br />

aggregate over the life of the warranty a sum greater than the<br />

owner's original cost of the Siplast-supplied<br />

materials and the labor used <strong>to</strong> install such materials.<br />

8 Notification requirements Written notice <strong>to</strong> Seaman Corporation, 1000 Venture Blvd., Written notice within 30 days after leak is discovered or should Written notice within 30 days after leak is discovered or<br />

Wooster, OH 44691, within 30 days after discovery of any by reasonable diligence have been discovered. should by reasonable diligence have been discovered.<br />

leaks in the roofing system.<br />

9 Exclusive or additional The owner's sole and exclusive remedy for failure of the Owner's exclusive remedy against Siplast regarding the roof Excludes other warranties; excludes UCC warranties.<br />

remedy roofing system; no employee or representative has authority <strong>to</strong> membrane; excludes all other warranties; excludes UCC<br />

make any representations other than those stated in warranty; warranties.<br />

excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Seaman's good faith determination. Neutral (no provision) Neutral (no provision)<br />

applicability<br />

12 Specific exclusions from 1, 3, 4, 5, 6, 7, 9, 10, 12, 18, 22, 24 1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 12, 15, 23 1, 2, 3, 4, 5, 6, 7, 8, 9, 12, 15, 23<br />

coverage (see Item 12 in<br />

Introduction)<br />

13 Wind coverage/exclusions Warranty excludes hurricanes and <strong>to</strong>rnadoes. Seaman Warranty excludes winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. Warranty excludes winds<strong>to</strong>rms, hurricanes, and <strong>to</strong>rnadoes.<br />

indicates that warranty covers roof damage resulting from<br />

wind speeds up <strong>to</strong> 73 mph.<br />

14 Specific conditions <strong>to</strong> make B, C C, H, R C, H, R<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain $7.00/square 5 years, $4.00/square; 10 years, $5.00/square None, if over 50 squares<br />

16 Minimum charge $750 $300 if less than 50 squares $300 if less than 50 squares<br />

17 Ineligible structure or <strong>Roof</strong>ing installations for personal, family, or household Cold-s<strong>to</strong>rage buildings and buildings with high-interior-- Cold-s<strong>to</strong>rage buildings and buildings with high-intbuilding<br />

use purposes. humidity problems. erior-humidity problems.<br />

804


18 Pre-construction notice and<br />

approval requirements<br />

19 Approved, authorized, or<br />

licensed requirements<br />

Contrac<strong>to</strong>r must submit FiberTite “request for warranty A guarantee application form listing job conditions and A guarantee application form listing job conditions and<br />

form/roof award information material submittal data” and requirements must be submitted and approved by Siplast requirements must be submitted and approved by Siplast<br />

obtain approval before material can be shipped. technical department prior <strong>to</strong> shipment of materials. technical department prior <strong>to</strong> shipment of materials.<br />

Yes Yes Yes<br />

20 Job inspection policy Seaman technical service representatives make on-site Inspections by Siplast field technical staff made prior and Inspections by field technical staff prior <strong>to</strong> and during<br />

inspections prior <strong>to</strong>, during (interim inspections coordinated during application periodically or as needed and after application as needed, after application and two years after<br />

with representative's travel schedule), and after completion, application; no charge. issuance of warranty; no charge.<br />

prior <strong>to</strong> issuance of warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation<br />

obligation<br />

22 Backed by named insurance<br />

or surety<br />

23 Issuing entity manufactures<br />

and/or sells products<br />

24 Conditions for renewal or<br />

extension<br />

Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

deficiencies for two years.<br />

Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

deficiencies for two years.<br />

No; Seaman indicates that it is self-insured. No; Siplast does not carry insurance covering its warranty No; Siplast does not carry insurance covering its warranty<br />

obligations.<br />

obligations.<br />

Seaman manufactures and sells the product. Siplast manufactures and sells product. Siplast manufactures and sells product.<br />

No renewal provision No renewal provision Siplast offers 5-year and 10-year addendum options <strong>to</strong><br />

extend the roof membrane guarantee. In order <strong>to</strong> obtain<br />

either the 5-year or 10-year extension, the owner must<br />

properly execute and return the Siplast Addendum <strong>to</strong> <strong>Roof</strong><br />

Membrane Guarantee <strong>to</strong> Siplast prior <strong>to</strong> issuance of the<br />

original guarantee. In order for the option <strong>to</strong> become<br />

effective, within six months prior <strong>to</strong> expiration of the original<br />

guarantee, the owner shall notify the Siplast technical<br />

department, in writing, <strong>to</strong> arrange for a free job inspection<br />

that will be made within 30 days by Siplast. The owner is <strong>to</strong><br />

have a Siplast-approved contrac<strong>to</strong>r effect properly all<br />

maintenance and non-roof membrane-related repairs deemed<br />

necessary by Siplast in accordance with Siplast's<br />

instructions and is <strong>to</strong> provide written verification that all such<br />

maintenance and repairs have been completed. Siplast will<br />

then invoice the owner for the guarantee extension charge<br />

in effect at time of extension. Current charges <strong>to</strong> extend the<br />

guarantee are $4.00/square for a 5-year extension and<br />

$10.00/square for a 10-year extension. Owner shall<br />

promptly pay <strong>to</strong> Siplast the renewal charges, after inspection<br />

and written verification that all maintenance and repairs<br />

have been completed in accordance with Siplast's<br />

instructions and specifications.<br />

25 Assignability Warranty may be assignable <strong>to</strong> a subsequent owner, only if No restrictions stated. No restrictions stated.<br />

the original owner requests in writing that Seaman Corporation<br />

consent <strong>to</strong> an assignment <strong>to</strong> the purchaser of the building,<br />

which consent will not be unreasonably withheld.<br />

26 Special features/condition The owner will be responsible for the cost of investigation if Warranty provides that the expense of removing and replacing Guarantee provides that the expense of removing and<br />

any leak is determined not <strong>to</strong> be covered by warranty. traffic surfaces built over the roof shall be borne by the owner. replacing traffic surfaces built over the roof shall be borne<br />

by the owner.<br />

27 Executed by owner Yes No No<br />

805


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Siplast, Inc. Soprema, Inc.<br />

2 Title, original publication<br />

date, and identifying symbol,<br />

if any<br />

Southwestern Petroleum Corporation<br />

(SWEPCO)<br />

<strong>Roof</strong> System Guarantee September 1996 Soprema, Inc. “Limited Warranty For <strong>Roof</strong>ing System”; Jan. “SWEPCO Brand <strong>Roof</strong>ing Products Limited Warranty”;<br />

1, 1997 December, 1993; J-7433-1293<br />

3 Product, specification, or Siplast roof membrane, Siplast Zonolite, Insulperm, NVS, Sopralene; 180, Flam 180, 180 Granules, Flam 180 Granules, 250, Flam Uni+Shield Single-Ply <strong>Roof</strong> System 302; Heavy Duty Cold<br />

system covered<br />

Insulcel and Zonocel roof insulation, and Zono-tite and NVS 250, 250 Granules, Flam 250 Granules, 350, 350 Granules, Flam Stick, Process BUR System 301; Uni+Shield II Cold Process BUR<br />

Flam 250 Alu, Flam 250 Copper, Jardin, Flam Antirock, Sopraseal;<br />

fasteners<br />

System 303<br />

Elas<strong>to</strong>phene; Flam, Granules, Flam Granules, PS, 180, 180 PS, Flam<br />

Granules FR, Granules FR, Flam Stick, Colphene Granules; Sopralast;<br />

Aluminum, Copper, Stainless, Mammouth Aluminum.<br />

4 Scope of coverage Material and workmanship; Siplast warrants that the roof system, comprised Material and workmanship; Soprema warrants that the roofing Material only; SWEPCO warrants that it will furnish sufficient<br />

membrane and flashing materials sold by Soprema will remain in a roofing material <strong>to</strong> correct any roof leaks that occur in warranted<br />

solely of the Siplast roof membrane, Siplast roof insulation, and Zono-tite or<br />

NVS fasteners, will remain in a watertight condition. Siplast warrants that<br />

the actual resistance <strong>to</strong> heat flow through the roof insulation will be at least<br />

80% of design thermal resistance provided that the roofing membrane is<br />

maintained free of leaks; if leaks occur, the insulating performance of the<br />

roof insulation will be at least 80% of design thermal resistance within a twoyear<br />

period following repair of the leak; the roof insulation will remain in a<br />

reroofable condition should the roof membrane require replacement.<br />

Damage <strong>to</strong> the roof insulation caused by a fastener pull-out during removal<br />

of the old membrane is excluded; the roof insulation will not cause structural<br />

damage <strong>to</strong> the building as a result of its expansion from thermal or chemical<br />

action. (See Special Features/Conditions.)<br />

5 Length of coverage 10 years: all systems; 10, 15, or 20 years<br />

15 and 20 years available for Paradiene 20/30 and Veral<br />

systems<br />

6 Nature of remedy If the roof systems does not remain in a watertight condition, Siplast will<br />

repair the roof system at its own expense. If the roof insulation fails <strong>to</strong><br />

perform as guaranteed, Siplast shall, at its own expense, make or cause <strong>to</strong><br />

be made repair or modifications <strong>to</strong> the roof insulation as Siplast deems<br />

appropriate so as <strong>to</strong> enable the roof insulation <strong>to</strong> perform as guaranteed.<br />

Siplast will be liable only for the cost of repair of the roof system by a Siplast<br />

approved contrac<strong>to</strong>r. The expense of removing and replacing traffic<br />

surfaces built over the roof shall be borne by owner<br />

watertight condition and that the roofing system is free from<br />

defects in material and installation at the time of application and<br />

that the materials in the roofing system conform <strong>to</strong> Soprema's<br />

specifications.<br />

Soprema will make repairs necessary <strong>to</strong> correct leaks in the<br />

roof membrane and flashing at its own expense, including all<br />

labor and materials, resulting from defects in material and<br />

faulty or improper installation in the roofing system or the<br />

failure of materials <strong>to</strong> meet Soprema specifications.<br />

applications solely as a result of a proven product defect.<br />

Uni+Shield: 5 years without extended-life coating option; Uni+Shield: 12<br />

years with extended-life coating option; #301: 10 years, 12/20 years -<br />

material only; #302: 5 years, 12/20 years -material only; #303: 10 years,<br />

12/20 years - materials only<br />

Replacement material only; SWEPCO will furnish materials<br />

required <strong>to</strong> repair leaks. Value of materials calculated at list<br />

prices current at the time of claim; under no circumstances<br />

are cash payments made.<br />

7 Monetary limitations None stated. None stated. Maximum aggregate value of replacement SWEPCO-brand roofing<br />

products recoverable over the life of the warranty shall not exceed the<br />

original invoiced price for warranted SWEPCO-brand roofing products.<br />

8 Notification requirements Written notice within 30 days after leak is discovered or<br />

should by reasonable diligence have been discovered<br />

Written notification within 30 days after any defect or leak is discovered or in Owner shall notify SWEPCO promptly and provide written confirmation by<br />

the exercise of ordinary care should have been discovered <strong>to</strong> Soprema, Inc. registered mail <strong>to</strong> SWEPCO at P.O. Box 961005, Ft. Worth, TX 761-<br />

at 310 Quadral Drive, Wadsworth, OH 44281.<br />

61-0005, within 14 days of discovery of any leaks.<br />

9 Exclusive or additional The owner's exclusive remedy against Siplast with respect <strong>to</strong> Warranty is sole and exclusive remedy against Soprema; excludes all other Owner accepts warranty as its sole and exclusive remedy;<br />

remedy<br />

the roof system; owner waives any and all other claims, warranties; Soprema not liable for special, incidental or consequential owner expressly waives any and all other claims; excludes UCC<br />

damages of any kind, whether arising from breach of contract, negligence,<br />

actions, and demands relating <strong>to</strong> roof system; excludes all<br />

warranties.<br />

breach of warranty or any other legal theory including loss of use of building<br />

other guarantees; excludes UCC warranties.<br />

or equipment, cost of capital, cost of substitute equipment, facilities or<br />

services, lost profits, downtime costs, or claims of cus<strong>to</strong>mers.<br />

10 Inclusion of consequential<br />

damages<br />

11 Determination of warranty<br />

applicability<br />

No No No<br />

Neutral Neutral (no provision) SWEPCO's determination<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 8, 9, 11, 12, 15, 23. Guarantee also 1, 2, 3, 4, 5, 6, 7, 9, 10, 12, 13 (including exposure <strong>to</strong><br />

1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 12, 13, 15, 16, 17, 19, 20, 22, 23<br />

coverage (see Item 12 in<br />

Introduction)<br />

specifically excludes chemical or organic deposits or other<br />

unusual occurrences.<br />

chloroflurocarbons, solvents, hydrocarbons, gasoline, acids,<br />

corrosives, salts, turpentine, oil, fat, grease, smoke, or fumes), 16,<br />

17, 20, 23. Warranty also excludes damage due <strong>to</strong> insect infestation,<br />

rodents, and vermin.<br />

806


13 Wind coverage/exclusions Siplast indicates guarantee covers roof damage resulting from Warranty excludes winds<strong>to</strong>rms in excess of Beaufort Number 8 of Warranty excludes damage <strong>to</strong> roof as a result of the wind,<br />

winds, but does not indicate covered wind speed. Guarantee the Beaufort Scale, hurricanes, and <strong>to</strong>rnadoes. Warranty covers regardless of its speed.<br />

excludes winds<strong>to</strong>rms, hurricanes, and <strong>to</strong>rnadoes. (Beaufort scale roof damage resulting from wind speeds up <strong>to</strong> 46 mph.<br />

defines s<strong>to</strong>rm as winds between 55 and 63 mph.)<br />

14 Specific conditions <strong>to</strong> make C, H, R A, B, C, F (including keeping all drains unclogged and properly A, B, C, G, H, M. Also failure <strong>to</strong> promptly apply replacement<br />

the warranty ineffective or working at all times, preventing excessive traffic across the roof products provided under warranty or provide written verification<br />

null and void (see Item 14 in and maintaining pitch pans and flashings in a watertight condition), of application will au<strong>to</strong>matically terminate warranty.<br />

Introduction)<br />

H, N, R<br />

15 Cost <strong>to</strong> obtain 10 yrs: no charge; 15 yrs: $7.50/sq; 20 yrs: $12.50/sq 10 yrs: no charge; 15 yrs: $7.50/sq; 20 yrs: $12.50/sq None<br />

16 Minimum charge $300 if less than 50 squares, plus normal per-square charge None None<br />

17 Ineligible structure or Cold-s<strong>to</strong>rage buildings and buildings with high humidity None None<br />

building use<br />

problems<br />

18 Pre-construction notice and A guarantee application form listing job conditions and Soprema requires a pre-bid approval from the specifier and None<br />

approval requirements requirements must be submitted and approved by Siplast contrac<strong>to</strong>r. Once received and approved, the respective parties<br />

technical department prior <strong>to</strong> shipment of materials.<br />

receive approval notification. (All approvals are registered with the<br />

home office).<br />

19 Approved, authorized, or Yes; the roofing contrac<strong>to</strong>r and lightweight concrete applica<strong>to</strong>r Yes No<br />

licensed requirements must be approved and licensed by Siplast.<br />

20 Job inspection policy Siplast field technical staff makes inspections prior <strong>to</strong>, during, and Soprema-authorized representative makes on-site inspections prior, during No on-site inspections<br />

after application prior <strong>to</strong> issuance of guarantee as well as two (depending on the circumstances), and after application prior <strong>to</strong> issuance of<br />

years after issuance of guarantee; no charge.<br />

warranty, as well as two years after issuance of warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship None<br />

obligation deficiencies for two years. deficiencies for two years.<br />

22 Backed by named insurance No; Siplast does not carry insurance covering its warranty No; Soprema indicates that it does not carry insurance No<br />

or surety obligations. covering its warranty obligations.<br />

23 Issuing entity manufactures Siplast manufactures and sells the products. Soprema manufactures and sells product. SWEPCO manufactures and sells PolyShield product;<br />

and/or sells products<br />

SWEPCO sells Uni+Shield product only.<br />

24 Conditions for renewal or Siplast offers 5- and 10-year options <strong>to</strong> extend the roof system guarantee. No renewal provision Warranty may be extended for 8 years. Extension is contingent<br />

extension In order <strong>to</strong> obtain either the 5- or 10-year extension, the owner must upon repairs and recoat at owners expense withing 6 months of<br />

properly execute and return the Siplast addendum <strong>to</strong> roof system guarantee<br />

expiration.<br />

<strong>to</strong> Siplast prior <strong>to</strong> issuance of the original guarantee. In order for the option<br />

<strong>to</strong> become effective, within six months prior <strong>to</strong> expiration of the original<br />

guarantee, the owner shall notify the Siplast technical department, in writing,<br />

<strong>to</strong> arrange for a free job inspection that will be made within 30 days by<br />

Siplast. The owner is <strong>to</strong> have a Siplast-approved contrac<strong>to</strong>r effect properly<br />

all maintenance and non-roof membrane-related repairs deemed necessary<br />

by Siplast in accordance with Siplast's instructions and is <strong>to</strong> provide written<br />

verification that all such maintenance and repairs have been completed.<br />

Siplast will then invoice the owner for the guarantee extension charge in<br />

effect at time of extension. Current charges <strong>to</strong> extend the guarantee are<br />

$4.00/square for a 5-year extension and $10.00/square for a 10-year<br />

extension. The owner shall promptly pay Siplast the renewal charges, after<br />

inspection and written verification that all maintenance and repairs have<br />

been completed in accordance with Siplast's instructions and specifications.<br />

25 Assignability The guarantee is assignable if Siplast is given at least 30 days written Warranty extends only <strong>to</strong> original owner and is not transferable or Any transfer of warranty <strong>to</strong> subsequent owners, purchasers, or<br />

notice prior <strong>to</strong> transfer and the intended building use is stated; an inspection assignable without prior written consent of Soprema. If repairs are required, tenants must be approved in writing by SWEPCO vice president<br />

of the roof/roof insulation system is made by Siplast; any repairs <strong>to</strong> the expense of removing and replacing traffic surfaces or other structures built of cus<strong>to</strong>mer service.<br />

roof/roof insulation system that may be deemed necessary by Siplast are over the roof shall be borne by owner.<br />

made at the owner's expense; and, the inspection and processing fee<br />

($300) is paid <strong>to</strong> Siplast.<br />

26 Special features/condition No claim may be made with respect <strong>to</strong> thermal performance of Siplast roof Any product sold by Soprema and not manufactured by Soprema is sold "as Any replacement products due under warranty will be made<br />

insulation unless based on tests carried out at owner's expense by a is" and without any warranty. Soprema dis-claims any liability or re- FOB SWEPCO's principal place of business or nearest<br />

qualified labora<strong>to</strong>ry using tests and procedures satisfac<strong>to</strong>ry <strong>to</strong> Siplast. sponsibility for specifications, design, warehouse.<br />

Siplast reserves the right <strong>to</strong> perform thermal testing of the roof insulation <strong>to</strong> or construction of any portion of the building, including the roofing system,<br />

be carried out at Siplast's direction and expense.<br />

except as stated in warranty. Warranty shall<br />

be construed according <strong>to</strong> laws of Ohio.<br />

27 Executed by owner No No No; however, SWEPCO’s order form, incorporating the warranty, requires<br />

buyer’s signature.<br />

807


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Tamko <strong>Roof</strong>ing Products, Inc. Tamko <strong>Roof</strong>ing Products, Inc. Tamko <strong>Roof</strong>ing Products, Inc.<br />

2 Title, original publication <strong>Roof</strong>ing System NDL Guarantee (A Limited Warranty); February Tam-Ply IV Guarantee (A Limited Warranty); November, 1999; Versa-Cap FR Labor and Material Guarantee (A Limited<br />

date, and identifying symbol, 1995; JP22254 997228 11/99 997296, JP21925 Warranty);” March 1, 1997; 997297<br />

if any<br />

3 Product, specification, or Built-up roofing specifications: 400 Series, 500 Series, 600 Tam-Ply IV Versa-Cap FR, Specification Series 700<br />

system covered<br />

Series; modified bitumen specifications: 100, 100 FR, 100 HW,<br />

100 C, 200, 200 FR, 200 C, 700 and 1000 Series<br />

4 Scope of coverage Material and workmanship; Tamko agrees <strong>to</strong> provide roof repair Material only; Tamko warrants that the Tam-Ply IV is free from Material only; Tamko warrants that the Versa-Cap FR is free<br />

services for leaks in the roofing system (e.g., membrane exclusive manufacturing defects that result in leaks from manufacturing defects that result in leaks<br />

of metal work and non-Tamko approved flashings) attributable <strong>to</strong><br />

ordinary wear and tear of the roofing system or workmanship<br />

deficiencies in application <strong>to</strong> the extent necessary <strong>to</strong> return the<br />

roofing system <strong>to</strong> a watertight condition.<br />

5 Length of coverage 5, 10, 12, or 15 years 10 years 10 years<br />

6 Nature of remedy Tamko will arrange for repairs <strong>to</strong> the roofing membrane and base If manufacturing defects result in leaks, Tamko shall have 90 days after If manufacturing defects result in leaks, Tamko shall have 90<br />

flashing and shall have no more than 90 days after receipt of receipt of notification <strong>to</strong> make repairs or cause repairs <strong>to</strong> be made <strong>to</strong> the days after receipt of notification <strong>to</strong> make repairs or cause repairs<br />

notification of leaks <strong>to</strong> make or cause <strong>to</strong> be made repairs or product, or will replace the same (exclusive of non-Tamko flashing and or replacement of the Versa-Cap FR <strong>to</strong> be made (exclusive of<br />

replacements unless prevented by acts of God. metal work and material used as a roof base over which the product is non-Tamko flashing and metal work and materials used as a<br />

applied and repairs required by defects therein) as required <strong>to</strong> prevent or roof base over which the Versa-Cap FR is applied and repairs<br />

repair leaks in the roof resulting from such manufacturing defects. required by defects therein) as required <strong>to</strong> prevent leaks in the<br />

Alternatively, at Tamko’s option, Tamko may tender payment <strong>to</strong> owner of the roof resulting from manufacturing defects.<br />

lesser of the reasonable cost of repairs or the prorated portion of Tamko’s<br />

maximum liability.<br />

7 Monetary limitations None stated. Tamko’s maximum liability shall be limited <strong>to</strong> the cost of labor and material Tamko’s maximum liability shall be limited <strong>to</strong> repair and<br />

<strong>to</strong> make repairs <strong>to</strong> the product containing a manufacturing defect which has replacement of Tamko materials up <strong>to</strong> a maximum liability over<br />

resulted in leaks up <strong>to</strong> a maximum liability over the term of the warranty of the term of the warranty of $100 per square for the first five<br />

$60 for each installed roofing square for the first five years; thereafter, years, reduced by 20 percent for each year following the initial<br />

Tamko’s liability shall be reduced by 20% for each year following the initial five years of the warranty of that portion of the Versa-Cap FR<br />

five years of that portion of the Tam-Ply IV containing a manufacturing containing a manufacturing defect which has resulted in leaks.<br />

defect which has resulted in leaks.<br />

8 Notification requirements Written notice <strong>to</strong> Tamko, P.O. Box 1404, Joplin, Missouri, 64802, Written notice by certified mail <strong>to</strong> Tamko at P.O. Box 1404, Joplin, Written notification by certified mail <strong>to</strong> result directly from<br />

no later than 30 days after discovery of a leak from any cause. MO 64802, within 30 days following discovery of any leaks alleged manufacturing Tamko at P.O. Box 1404, Joplin, MO 64802<br />

<strong>to</strong> result directly from manufacturing defects<br />

within 30 days following discovery of any leaks alleged <strong>to</strong><br />

defects<br />

9 Exclusive or additional The obligation contained in guarantee is expressly in lieu of any Guarantee is in lieu of any other obligations, guarantees, Guarantee is in lieu of any other obligations, guarantees,<br />

remedy other guarantees, warranties, obligations, or liability on the part of warranties, or liabilities on the part of Tamko; excludes UCC warranties, or liabilities on the part of Tamko; excludes UCC<br />

Tamko; excludes UCC warranties. warranties. No representative, employee, agent of Tamko, or any warranties.<br />

person other than the President of Tamko, has any authority <strong>to</strong><br />

assume for Tamko any additional or other liability or responsibility.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Solely Tamko will determine the condition of water tightness Tamko’s determination Tamko’s determination<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 6, 7, 8, 11, 12, 13, 15, 23, 24; exposure <strong>to</strong> ionized 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 (including exposure from 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 (including exposure from<br />

coverage (see Item 12 in radiation or contamination by radioactivity from any nuclear aliphatic or aromatic solvents, chlorinated hydrocarbons, aliphatic or aromatic solvents, chlorinated hydrocarbons,<br />

Introduction) source. turpentine, oils, or organic or inorganic polar materials, and turpentine, oils, organic or inorganic polar materials, and<br />

exposure <strong>to</strong> ionized radiation or contamination by radioactivity exposure <strong>to</strong> ionized radiation or contamination by radioactivity<br />

from any nuclear source), 15, 17, 19, 20, 22, 23. from any nuclear source), 15, 19, 20, 22, 23<br />

13 Wind coverage/exclusions The warranty excludes strong gales, winds<strong>to</strong>rms, hurricanes, <strong>to</strong>rnadoes and Tamko indicates warranty covers roof damage resulting from wind speeds Tamko indicates warranty covers roof damage resulting from<br />

violent s<strong>to</strong>rms. (Strong gales are defined on the Beaufort Scale as winds up <strong>to</strong> strong gales. Warranty excludes strong gales, winds<strong>to</strong>rms, violent wind speeds up <strong>to</strong> 54 mph. Warranty excludes strong gales,<br />

between 47 and 54 mph and s<strong>to</strong>rms are defined as winds between 55 and s<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. (Strong gales are defined on the Beufort winds<strong>to</strong>rms, violent s<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes.<br />

63 mph.) Scales as winds between 47 and 54 mph.)<br />

808


14 Specific conditions <strong>to</strong> make A, B, C, F, K, N A, K K<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain 5 yrs: $4.00/sq; 10 yrs: $8.50/sq; None None<br />

12 yrs: $9.00/sq; 15 yrs: $12.50/sq<br />

16 Minimum charge 5 yrs: $400; 10 yrs: $ 850; None None<br />

12 yrs: $850; 15 yrs: $1,000<br />

17 Ineligible structure or Individual residences, condominiums, cooperative apartments, None Cold-s<strong>to</strong>rage facilities, individual residences, condominiums,<br />

building use heated tanks, s<strong>to</strong>rage silos, dry kilns, car wash buildings, cooperative apartments, heated tanks, s<strong>to</strong>rage silos, dry kilns,<br />

swimming pools, and other structures with high-humidity<br />

car wash buildings, swimming pools, other structures with highconditions<br />

humidity conditions.<br />

18 Pre-construction notice and The contrac<strong>to</strong>r is required <strong>to</strong> submit a request for issuance of None None<br />

approval requirements guarantee describing the job at least two weeks prior <strong>to</strong> the<br />

commencement of the job. Job specifications must be in<br />

accordance with Tamko's published specifications and<br />

recommendations unless changes are approved in writing by<br />

Tamko's manager of technical services.<br />

19 Approved, authorized, or Yes No No<br />

licensed requirements<br />

20 Job inspection policy Tamko representative makes inspection after completion, prior <strong>to</strong> No on-site inspections No on-site inspections<br />

issuing warranty and, two years after issuing warranty. Tamko<br />

representative makes on-site inspection during application for<br />

specification 243 only; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship None; material-only warranty None; material-only warranty<br />

obligation<br />

deficiencies for two years.<br />

22 Backed by named insurance No; Tamko indicates that it does not carry insurance covering its No; Tamko indicates that it does not carry insurance covering its No; Tamko indicates that it does not carry insurance covering its<br />

or surety warranty obligations warranty obligations. warranty obligations.<br />

23 Issuing entity manufactures Tamko manufactures and sells the product. Tamko manufactures and sells the products Tamko manufacturers and sells the products<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability The guarantee shall accrue and inure only <strong>to</strong> the benefit of the first Guarantee cannot be assigned, sold or transferred in any manner Not transferable or assignable in any manner; warranty accrues<br />

consumer purchaser or owner of the Tamko product and shall not whatsoever. Warranty inures only <strong>to</strong> the benefit of the owner of and inures only <strong>to</strong> the benefit of the first consumer purchaser or<br />

be assigned, sold or transferred in any manner whatsoever. the building <strong>to</strong> which the product is applied on the date of owner.<br />

application.<br />

26 Special features/condition No action for breach of this limited warranty may be brought later<br />

than one year after any cause of action has accrued.<br />

Nothing contained in the guarantee shall be construed <strong>to</strong> be a<br />

waiver of Tamko's right for contribution or indemnity for any liability<br />

incurred as a result of this guarantee. No representative,<br />

employee, agent of Tamko or any other person has any authority<br />

<strong>to</strong> assume for Tamko any additional or other liability or<br />

responsibility. Tamko shall not be responsible for or liable if there<br />

is any change or amendment <strong>to</strong> the Tamko built-up roof<br />

specification, unless such change or amendment is approved in<br />

writing by Tamko.<br />

Claims under warranty will require documentary proof of purchase.<br />

Tamko is not responsible for any cost related <strong>to</strong> the removal or<br />

Tamko requires that the owner initiate and follow a preventive<br />

abatement of any asbes<strong>to</strong>s present in the existing roof <strong>to</strong> which the<br />

maintenance program substantially in accordance with recommendations Versa-Cap FR is applied. Tamko requires that the owner initiate and<br />

found on the reverse side of warranty. Specific maintenance items listed on follow a preventive maintenance program substantially in accordance<br />

reverse of guarantee must be performed at least semiannually <strong>to</strong> maintain with the preventive recommendations found on the reverse side of<br />

coverage guarantee. Coatings over smooth surfaced products must be warranty. Specific maintenance items listed on reverse of guarantee<br />

maintained <strong>to</strong> provide surface protection. Tamko is not responsible for any must be performed at least semiannually <strong>to</strong> maintain guarantee coverage.<br />

cost related <strong>to</strong> the removal or abatement of any asbes<strong>to</strong>s present in the Coatings over smooth surfaced products must be maintained <strong>to</strong> provide<br />

existing roof <strong>to</strong> which the Tam-Ply IV is applied.<br />

surface protection.<br />

No action for breach of warranty or any other action relating <strong>to</strong> the Warranty may not be modified except in a writing signed by Tamko’s<br />

Tamko product, its purchase or the warranty shall be brought later than one president. No representative, employee, agent of Tamko or any person,<br />

year after any cause of action has accrued in jurisdictions where statu<strong>to</strong>ry other than the president of Tamko, has any authority <strong>to</strong> assume for<br />

claims or implied warranties cannot be excluded.<br />

Tamko any additional or other liability or responsibility.<br />

Warranty is not valid in Hawaii, Alaska, and California. A separate Warranty is not valid in Hawaii, Alaska and California. A separate<br />

limited warranty is available for products used in California. Products are limited warranty is available for products used in California. Products are<br />

sold “AS IS” and “WITH ALL FAULTS” when used outside of the 48 sold “as is” and “with all faults” when used outside of the 48 contiguous<br />

contiguous United States.<br />

United States.<br />

No action for breach of this limited warranty shall be brought later than<br />

one year after any cause of action has accrued.<br />

27 Executed by owner No No No<br />

809


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Tamko <strong>Roof</strong>ing Products, Inc. Tamko <strong>Roof</strong>ing Products, Inc. Tamko <strong>Roof</strong>ing Products, Inc.<br />

2 Title, original publication “Commercial <strong>Roof</strong>ing Guarantee (A Limited Warranty);” Oc<strong>to</strong>ber, “Premium <strong>Roof</strong>ing System NDL Guarantee (A Limited Warranty)”; “<strong>Roof</strong>ing Systems Guarantee (A Limited Warranty)”; February<br />

date, and identifying symbol, 1999; 10/99 997295, JP21926 February 1995; JP22255 997226 1995; 997225<br />

if any<br />

3 Product, specification, or Awaplan Premium FR, Awaplan Premium, Awaplan Heat Welding, BUR specifications 503, 507; modified bitumen specifications 103, BUR specification 500 series, 600 series; modified bitumen<br />

system covered Awaplan 170 FR, Awaplan 170, Awaplan Versa-Smooth, Awaflex 108, 109, 103 HW, 108 HW, 109 HW, 103 FR, 108 FR, 109 FR. specification 100, 100 FR, 100 HW, 100C, 200, 200 FR, 200C,<br />

FR, Awaflex, Awaplan VersaFlex, Tam-Glass Premium, Vapor- Base flashings must use Premium Grade Awaplan. 700 series. This guarantee is intended for recover systems over<br />

Chan, Glass-Base Sheet, Base-N-Ply, Versa-Base<br />

existing roofs and certain other Tamko specifications.<br />

4 Scope of coverage Material only; Tamko warrants that its product is free from Material and workmanship; Tamko agrees <strong>to</strong> provide roof repair services for Material and workmanship; Tamko agrees <strong>to</strong> provide roof repair services<br />

manufacturing defects that result in leaks. leaks in the roofing system (exclusive of metal work and non-Tamko- for leaks in the roof system (exclusive of metal work and non-Tamkoapproved<br />

flashings) attributable <strong>to</strong> ordinary wear and tear of the roofing approved flashings) attributable <strong>to</strong> ordinary wear and tear of the roofing<br />

system or workmanship deficiencies in application <strong>to</strong> the extent necessary system or workmanship deficiencies in application <strong>to</strong> the extent<br />

<strong>to</strong> return the roofing system <strong>to</strong> a watertight condition.<br />

necessary <strong>to</strong> return the roofing system <strong>to</strong> a watertight condition.<br />

5 Length of coverage 5 years: Vapor-Chan, Glass-Base, Base-N-Ply, Versa-Base; 10 20 years 5, 10, 12, or 15 years<br />

years: Awaflex FR, Awaflex, Awaplan Versaflex, Tam-Glass<br />

Premium; 12 years: Awaplan 170 FR, Awaplan 170, Awaplan<br />

Versa-Smooth; 15 years: Awaplan Premium FR, Awaplan<br />

Premium, Awaplan Heat Welding<br />

6 Nature of remedy If manufacturing defects result in leaks, Tamko shall have 90 days after Tamko will arrange for repair <strong>to</strong> the roofing membrane and base Tamko will arrange for repair <strong>to</strong> the roofing membrane and base<br />

receipt of notification <strong>to</strong> make repairs or cause repairs <strong>to</strong> be made <strong>to</strong> the flashing. Tamko shall have no more than 90 days after receipt of flashing. Tamko shall have no more than 90 days after receipt<br />

product, or will replace the same (exclusive of non-Tamko flashing and notification of leaks <strong>to</strong> make or cause <strong>to</strong> be made repairs or of notification of leaks <strong>to</strong> make or cause <strong>to</strong> be made repairs or<br />

metal work and material used as a roof base over which the product is replacement unless otherwise prevented by acts of God. Prior <strong>to</strong> replacement unless otherwise prevented by acts of God. Prior<br />

applied and repairs required by defects therein) as required <strong>to</strong> prevent or the expiration of such 90-day period, Tamko will not be liable for <strong>to</strong> the expiration of such 90-day period, Tamko will not be liable<br />

repair leaks in the roof resulting from such manufacturing defects. any cost of repair or replacement unless Tamko has given its for any cost of repair or replacement unless Tamko has given its<br />

Alternatively, at Tamko’s option, Tamko may tender payment <strong>to</strong> the owner of written approval. written approval.<br />

the cost of labor and materials <strong>to</strong> make repairs <strong>to</strong> the Tamko product.<br />

7 Monetary limitations Tamko’s maximum liability shall be limited <strong>to</strong> the cost of labor and None stated. Tamko inserts maximum <strong>to</strong>tal liability in guarantee form prior <strong>to</strong><br />

material <strong>to</strong> make repairs <strong>to</strong> the product containing a manufacturing<br />

issuance. Tamko indicates $100/square is the usual limitation<br />

defect which has resulted in leaks. The extent of repair or<br />

inserted by Tamko at the time of issuance of guarantee.<br />

replacement is at the sole discretion of Tamko.<br />

8 Notification requirements Written notice by certified mail of any leaks alleged <strong>to</strong> result Written notice <strong>to</strong> Tamko no later than 30 days after discovery of Written notice <strong>to</strong> Tamko no later than 30 days after discovery of<br />

directly from manufacturing defects within 30 days following any leaks. any leaks.<br />

discovery <strong>to</strong> Tamko at P.O. Box 1404, Joplin, MO 64802.<br />

9 Exclusive or additional Guarantee is in lieu of any other obligations, guarantees, warrantees, any The guarantee is in lieu of any other obligations, guarantees, The guarantee is in lieu of any other obligations, guarantees,<br />

remedy other obligations or liability on the part of Tamko; excludes UCC warranties. warranties, or liability on the part of Tamko; excludes UCC warranties, or liability on the part of Tamko; excludes UCC<br />

Warranty may not be modified except in writing signed by Tamko’s warranties. warranties.<br />

President. No representative, employee, agent of Tamko, or any person<br />

other than the President of Tamko, has any authority <strong>to</strong> assume for Tamko<br />

any additional or other liability or responsibility.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Tamko’s determination Tamko will solely determine the condition of water tightness. Tamko will solely determine the condition of water tightness.<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 (including exposure from 1, 2, 3, 4, 6, 7, 8, 11, 12, 13 (including exposure from aliphatic or 1, 2, 3, 4, 6, 7, 8, 11, 12, 13 (including exposure from aliphatic<br />

coverage (see Item 12 in aliphatic or aromatic solvents, chlorinated hydrocarbons, aromatic solvents, chlorinated hydrocarbons, turpentine, oils or or aromatic solvents, chlorinated hydrocarbons, turpentine, oils<br />

Introduction) turpentine, oils, or organic or inorganic polar materials, and organic or inorganic polar materials, and exposure <strong>to</strong> ionized or organic or inorganic polar materials, and exposure <strong>to</strong> ionized<br />

exposure <strong>to</strong> ionized radiation or contamination by radioactivity radiation or contamination by radio-activity from any nuclear radiation or contamination by radio-activity from any nuclear<br />

from any nuclear source), 15, 17, 19, 20, 22, 23. source), 15, 18, 20, 23 source), 15, 18, 20, 23.<br />

13 Wind coverage/exclusions Tamko indicates warranty covers roof damage resulting from wind The warranty excludes strong gales, winds<strong>to</strong>rms, violent s<strong>to</strong>rms, The warranty excludes strong gales, winds<strong>to</strong>rms, violent s<strong>to</strong>rms,<br />

speeds up <strong>to</strong> strong gales. Warranty excludes strong gales, hurricanes, and <strong>to</strong>rnadoes. (Tamko does not indicate what wind hurricanes and <strong>to</strong>rnadoes. Tamko does not indicate wind<br />

winds<strong>to</strong>rms, violent s<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. (Strong speeds are covered by guarantee. Strong gales are defined on speeds covered by guarantee.<br />

gales are defined on the Beufort Scales as winds between 47 and the Beaufort Scale as s<strong>to</strong>rms with winds between 55-63 mph and<br />

54 mph.) s<strong>to</strong>rms as having winds between 47 and 54 mph.)<br />

810


14 Specific conditions <strong>to</strong> make A, K B, C, F, K B (Tamko may, at its option, cancel the guarantee), C<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain None $17.50/square 5 years: $4.00/square; 10 years: $8.50/square;<br />

12 years: $9.00/square; 15 years: $12.50/square<br />

16 Minimum charge None $1,200 5 yrs: $400; 10 yrs: $ 850;<br />

12 yrs: $850; 15 yrs: $1,000<br />

17 Ineligible structure or None Individual residences, condominiums, cooperative apartments, Individual residences, condominiums, cooperative apartments,<br />

building use heated tanks, s<strong>to</strong>rage silos, dry kilns, car wash buildings, heated tanks, s<strong>to</strong>rage silos, dry kilns, car wash buildings,<br />

swimming pools, and other structures with high-humidity<br />

swimming pools, and other structures with high-humidity<br />

conditions.<br />

conditions.<br />

18 Pre-construction notice and No The contrac<strong>to</strong>r is required <strong>to</strong> submit a request for issuance of The contrac<strong>to</strong>r is required <strong>to</strong> submit a request for issuance of<br />

approval requirements guarantee describing the job at least two weeks prior <strong>to</strong> the guarantee describing the job at least two weeks prior <strong>to</strong> the<br />

commencement of the job. Job specifications must be in commencement of the job. Job specifications must be in<br />

accordance with Tamko's published specifications and<br />

accordance with Tamko's published specifications and<br />

recommendations unless changes are approved in writing by recommendations unless changes are approved in writing by<br />

Tamko's manager of technical services.<br />

Tamko's manager of technical services.<br />

19 Approved, authorized, or No Yes Yes<br />

licensed requirements<br />

20 Job inspection policy No on-site inspections Tamko representative makes inspection after completion prior <strong>to</strong> Tamko built-up roofing representative makes inspection after<br />

issuance of guarantee and two years after issuing of guarantee. completion prior <strong>to</strong> issuance of guarantee and two years after<br />

Tamko representative makes on-site inspection during application issuing of guarantee. Tamko representative makes on-site<br />

of specification 243 only; no charge<br />

inspection during application for specification 243 only; no<br />

charge.<br />

21 Contrac<strong>to</strong>r’s post-installation None; material-only warranty The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

obligation deficiencies for two years. deficiencies for two years.<br />

22 Backed by named insurance No; Tamko indicates that it does not carry insurance covering its No; Tamko indicates that it does not carry insurance covering its No; Tamko indicates that it does not carry insurance covering its<br />

or surety warranty obligations warranty obligations warranty obligations<br />

23 Issuing entity manufactures Tamko manufactures and sells the products. Tamko <strong>Roof</strong>ing Products, Inc. manufactures and sells the Tamko <strong>Roof</strong>ing Products, Inc. manufactures and sells the<br />

and/or sells products products. products.<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability Guarantee cannot be assigned, sold or transferred in any manner The guarantee cannot be assigned, sold, or transferred in any Not transferable in any manner.<br />

whatsoever. Warranty inures only <strong>to</strong> the benefit of the owner of manner whatsoever. The warranty inures only <strong>to</strong> the benefit of the<br />

the building <strong>to</strong> which the product is applied on the date of first consumer, purchaser, or owner of the Tamko product.<br />

application.<br />

26 Special features/condition Claims under warranty will require documentary proof of purchase. Tamko is not responsible for cost related <strong>to</strong> the removal or Tamko is not responsible for cost related <strong>to</strong> the removal or<br />

Tamko requires that the owner initiate and follow a preventive abatement of any asbes<strong>to</strong>s present in the existing roof system <strong>to</strong> abatement of any asbes<strong>to</strong>s present in the existing roof system<br />

maintenance program substantially in accordance with the preventive<br />

which Tamko roof system is applied.<br />

<strong>to</strong> which Tamko roof system is applied.<br />

maintenance recommendations found on the reverse side of the warranty.<br />

Specific maintenance items listed on reverse side of guarantee must be<br />

No action for breach of warranty shall be brought later than one No action for breach of warranty shall be brought later than<br />

performed at least semiannually <strong>to</strong> maintain guarantee coverage. Coatings year after any cause of action has occurred. Nothing contained in one year after any cause of action has occurred. Nothing<br />

over smooth-surfaced products must be maintained <strong>to</strong> provide surface the guarantee shall be construed <strong>to</strong> be a waiver of Tamko's right contained in the guarantee shall be construed <strong>to</strong> be a waiver of<br />

protection. Tamko is not responsible for any cost related <strong>to</strong> the removal or for contribution or indemnity.<br />

Tamko's right for contribution or indemnity.<br />

abatement of any asbes<strong>to</strong>s present in the existing roof <strong>to</strong> which the Tamko No representative, employee, agent of Tamko, or any other No representative, employee, agent of Tamko, or any other<br />

product is applied.<br />

person has any authority <strong>to</strong> assume for Tamko any additional or person has any authority <strong>to</strong> assume for Tamko any additional or<br />

No action for breach of warranty or any other action relating <strong>to</strong> the<br />

other liability or responsibility.<br />

other liability or responsibility.<br />

Tamko product, its purchase or the warranty shall be brought later than one<br />

year after any cause of action has accrued in jurisdictions where statu<strong>to</strong>ry<br />

claims or implied warranties cannot be excluded.<br />

Warranty is not valid in Hawaii, Alaska and California. A separate limited<br />

warranty is available for products used in California. Products are sold “AS<br />

IS” and “WITH ALL FAULTS” when used outside of the 48 contiguous<br />

United States<br />

27 Executed by owner No No No<br />

811


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Tamko <strong>Roof</strong>ing Products, Inc. Tamko <strong>Roof</strong>ing Products, Inc. Texas Refinery Corporation (TRC)<br />

2 Title, original publication Total System Coverage Guarantee (A Limited Warranty); February Ten Year Limited Material Warranty (A Limited Warranty) January Texas Refinery Corporation's Limited <strong>Roof</strong> System Warranty;<br />

date, and identifying symbol, 1995; JP22287 997227 1996; JP32996 997574 1988; 2M0488<br />

if any<br />

3 Product, specification, or Built-up roofing specifications: All insulated specifications in 400, Speedweld (Smooth) MightyPlate Single-Ply; MightyPlate Two-Ply System; Mightysystem<br />

covered 500 and 600 series; modified bitumen specifications: All insulated Plate Liquid Type II Glasbase <strong>Roof</strong> System; MightyPlate Liquid<br />

specifications in series 100, 200, 700 and 1000<br />

Poly-Mat <strong>Roof</strong> System; MightyPlate Liquid MightyPly <strong>Roof</strong><br />

System.<br />

4 Scope of coverage Material and workmanship; Tamko agrees <strong>to</strong> provide roof repair services for Material only; Tamko warrants <strong>to</strong> the first consumer purchaser or<br />

leaks in the roofing system (e.g., membrane exclusive of metal work and owner that the Tamko product will, at the time of purchase, be free<br />

non-Tamko approved flashings) attributable <strong>to</strong> ordinary wear and tear of the<br />

from manufacturing defects that result in leaks.<br />

roofing system or workmanship deficiencies in application <strong>to</strong> the extent<br />

necessary <strong>to</strong> return the roofing system <strong>to</strong> a watertight condition.<br />

Material only; TRC agrees <strong>to</strong> furnish sufficient roofing materials <strong>to</strong> repair<br />

leaks through the roofing system caused by natural deterioration resulting<br />

from ordinary wear and tear by the elements; blisters, fishmouths, ridges,<br />

wrinkles, and splits, unless due <strong>to</strong> movement or failure of the substrate<br />

over which the roofing system is installed; and slippage of the roofing<br />

system.<br />

5 Length of coverage 5, 10, 12, 15, or 20 years 10 years 5 years: MightyPlate Modified Bitumen <strong>Roof</strong> Membrane, MightyPly<br />

System, MightyPlate Liquid Type II Glasbase <strong>Roof</strong> System, MightyPlate<br />

Liquid Poly-Mat <strong>Roof</strong> System; 10 years: MightyPlate Modified Bitumen<br />

<strong>Roof</strong> Membrane, MightyPlate Liquid Type II Glasbase <strong>Roof</strong> System,<br />

MightyPlate Liquid Poly-Mat <strong>Roof</strong> System with aluminum roof coating or<br />

Texotropic surfacing; MightyPly System with aluminum roof coating,<br />

texotropic or Ceramic Granules.<br />

6 Nature of remedy Tamko will arrange for repairs <strong>to</strong> the roofing membrane and base If Tamko determines there are manufacturing defects covered by the TRC agrees <strong>to</strong> furnish without charge, F.O.B. closest U.S.A.<br />

flashing and shall have no more than 90 days after receipt of warranty, Tamko shall have 90 days after receipt of notification <strong>to</strong> either (1) warehouse, sufficient TRC roofing patching material <strong>to</strong> s<strong>to</strong>p<br />

notification of leaks <strong>to</strong> make or cause <strong>to</strong> be made repairs or<br />

refund the lesser of: (a) the cost of repairs <strong>to</strong> the roofing membrane <strong>to</strong><br />

leaks.<br />

res<strong>to</strong>re its watertight integrity, or (b) the prorated portion of the purchase<br />

replacements unless prevented by acts of God.<br />

price of the product; or (2) replace a portion of the product, based upon a<br />

prorating schedule ranging from 100% in years one and two <strong>to</strong> 10% in year<br />

ten. Prior <strong>to</strong> the expiration of such 90-day period, Tamko shall not be liable<br />

for any cost of repair or replacement unless Tamko has given its written<br />

approval of the repair or replacement of defective product and the cost<br />

thereof.<br />

7 Monetary limitations None stated. For first and second year, Tamko's liability limited <strong>to</strong> the amount of original TRC's obligation <strong>to</strong> furnish additional material is not <strong>to</strong> exceed<br />

purchase price; 90% in year three; 70% in year four; 60% in year five; 50%<br />

in year six; 40% in year seven; 30% in year eight; 20% in year nine; and<br />

original purchase amount.<br />

10% in year ten.<br />

8 Notification requirements Written notice <strong>to</strong> Tamko, P.O. Box 1404, Joplin, Missouri, 64802, Written notice by certified mail of any leaks alleged <strong>to</strong> result Notification <strong>to</strong> TRC within 30 days of discovery of leak,<br />

no later than 30 days after discovery of a leak from any cause. directly from manufacturing defects within 30 days following confirming oral notice in writing within 10 days<br />

discovery <strong>to</strong> Tamko, P.O. Box 1404, Joplin, MO 64802.<br />

9 Exclusive or additional The obligation contained in guarantee is expressly in lieu of any<br />

remedy<br />

other guarantees, obligations or liability on the part of Tamko;<br />

excludes UCC warranties.<br />

The warranty is expressly in lieu of any and all other obligations, guarantees<br />

and warranties; Tamko's obligation <strong>to</strong> refund the cost of repair, a portion of<br />

the product's original purchase cost or <strong>to</strong> replace a portion of the product, in<br />

accordance with the prorating schedule, shall be the sole and exclusive<br />

remedy against Tamko under the warranty or otherwise; excludes UCC<br />

warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

TRC's exclusive responsibility and liability is <strong>to</strong> furnish sufficient patching<br />

materials <strong>to</strong> maintain the roofing system in a watertight condition; owner<br />

recognizes and agrees that TRC has no liability for any alleged breach of<br />

warranty, negligence, strict liability or any other theory or damage of any<br />

nature whatsoever other than limited and exclusive liability set forth in<br />

warranty document.<br />

11 Determination of warranty Solely Tamko will determine the condition of water tightness Tamko's determination Neutral; TRC arranges for inspection once leak reported.<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 6, 7, 8, 11, 12, 13, 15, 23, 24; exposure <strong>to</strong> ionized 1, 2, 3, 4, 6, 7, 8, 11, 12, 13 (including exposure from aliphatic or aromatic 1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 15, 20, 22, 23 (Also excludes<br />

coverage (see Item 12 in radiation or contamination by radioactivity from any nuclear source solvents, chlorinated hydrocarbons, turpentine, oils, organic or inorganic damages due <strong>to</strong> unauthorized test cuts.)<br />

polar materials, and exposure <strong>to</strong> ionized radiation or contamination by<br />

Introduction)<br />

radioactivity from any nuclear source), 15, 19, 23. The warranty excludes<br />

damage due <strong>to</strong> splitting, cracking, blistering, delamination, or separation<br />

due <strong>to</strong> underlying materials.<br />

13 Wind coverage/exclusions The warranty excludes strong gales, winds<strong>to</strong>rms, hurricanes, <strong>to</strong>rnadoes and The warranty excludes strong gales, winds<strong>to</strong>rms, violent s<strong>to</strong>rms, hurricanes, Warranty excludes winds<strong>to</strong>rms, hurricanes, and <strong>to</strong>rnadoes.<br />

violent s<strong>to</strong>rms. (Strong gales are defined on the Beaufort Scale as s<strong>to</strong>rms and <strong>to</strong>rnadoes. (Tamko does not indicate what wind speeds are covered by [TRC indicates that there is no coverage for damage caused by<br />

with winds between 47 and 54 mph and s<strong>to</strong>rms are defined as winds the warranty; the Beaufort Scale defines a strong gale as winds between 47<br />

wind.]<br />

between 55 and 63 mph.)<br />

and 54 mph.)<br />

812


14 Specific conditions <strong>to</strong> make A, B, C, F, K, N C, G, K, R, (The warranty states that Tamko's obligations under the M (See Special Features/Conditions.)<br />

the warranty ineffective or<br />

warranty shall terminate if (1) Tamko is not reimbursed for all reasonable expenses,<br />

including, but not limited <strong>to</strong>, transportation, meals and lodging,<br />

null and void (see Item 14 in<br />

associated with the inspection of a complaint, within 30 days of receipt of<br />

Introduction)<br />

invoice from Tamko when Tamko has determined that the complaint is<br />

expressly excluded by the terms of the warranty; or (2) the owner fails <strong>to</strong><br />

reimburse Tamko for any additional costs incurred by Tamko attributable <strong>to</strong><br />

the lack of reasonable access <strong>to</strong> the roof within 30 days of receipt of invoice<br />

from Tamko.<br />

15 Cost <strong>to</strong> obtain 5 yrs: $4.00/sq; 10 yrs: $8.50/sq; 12 yrs: $9.00/sq; None None<br />

15 yrs: $12.50/sq; 20 yrs: $17.50/sq<br />

16 Minimum charge 5 yrs: $ 400; 10 yrs: $ 850; 12 yrs: $850; None None<br />

15 yrs: $1,000; 20 yrs: $1,200<br />

17 Ineligible structure or<br />

building use<br />

Individual residences, condominiums, cooperative apartments, heated Individual residences, condominiums, cooperative apartments, heated Cold-s<strong>to</strong>rage buildings; residential<br />

tanks, s<strong>to</strong>rage silos, dry kilns, car wash buildings, swimming pools, and tanks, s<strong>to</strong>rage silos, dry kilns, car wash buildings, swimming pools, and<br />

other structures with high-humidity conditions.<br />

other structures with high-humidity conditions<br />

18 Pre-construction notice and<br />

approval requirements<br />

The contrac<strong>to</strong>r is required <strong>to</strong> submit a request for issuance of guarantee<br />

describing the job at least two weeks prior <strong>to</strong> the commencement of the job.<br />

Job specifications must be in accordance with Tamko's published<br />

specifications and recommendations unless changes are approved in writing<br />

by Tamko's manager of technical services.<br />

None<br />

None required<br />

19 Approved, authorized, or<br />

licensed requirements<br />

Yes No No<br />

20 Job inspection policy Tamko representative makes inspection after completion, prior <strong>to</strong> issuing<br />

warranty and, two years after issuing warranty. Tamko representative<br />

makes on-site inspection during application for specification 243 only; no<br />

charge.<br />

No on-site inspections.<br />

Inspection made by TRC sales consultant prior, at least two times<br />

during, and after completion, as well as two years after issuance of<br />

warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation<br />

obligation<br />

The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

deficiencies for two years.<br />

None; material only warranty<br />

Although this is a material-only warranty, contrac<strong>to</strong>r obligated <strong>to</strong> make<br />

repairs <strong>to</strong> all leaks and any defects, including materials and<br />

workmanship, for two years.<br />

22 Backed by named insurance or<br />

surety<br />

23 Issuing entity manufactures<br />

and/or sells products<br />

24 Conditions for renewal or<br />

extension<br />

No; Tamko indicates that it does not carry insurance covering its No; Tamko indicates that it does not carry insurance covering its No; TRC indicates that it carries insurance covering its warranty<br />

warranty obligations warranty obligations obligations and that TRC home office should be contacted for<br />

details.<br />

Tamko manufactures and sells the product Tamko manufactures and sells the product. TRC manufactures and sells product.<br />

No renewal provision No renewal provision No renewal provision<br />

25 Assignability The guarantee shall accrue and inure only <strong>to</strong> the benefit of the first<br />

consumer purchaser or owner of the Tamko product and shall not be<br />

assigned, sold or transferred in any manner whatsoever<br />

The warranty shall accrue and inure only <strong>to</strong> the benefit of the first consumer<br />

purchaser or owner of the Tamko product and shall not be assigned, sold, or<br />

transferred in any manner whatsoever. Any assignment, sale or transfer of<br />

the warranty or of the building <strong>to</strong> which the product is applied shall void all<br />

warranties.<br />

No restrictions stated.<br />

26 Special features/condition No action for breach of this limited warranty may be brought later Claims under warranty will require proof of purchase by first consumer purchaser or No representative, employee, or agent of TRC or any other<br />

owner. Tamko shall not be responsible for any claims without such proof of<br />

than one year after any cause of action has accrued.<br />

purchase.<br />

person other than the TRC manager of technical services,<br />

Nothing contained in the guarantee shall be construed <strong>to</strong> be a The warranty states that owner acknowledges that it is the owner's sole located in Fort Worth, Texas, has any authority <strong>to</strong> change, alter,<br />

waiver of Tamko's right for contribution or indemnity for any liability responsibility <strong>to</strong> determine that the product has been installed in compliance with (I) or modify the provisions of this warranty. In the event that (a)<br />

any contract specifications provided by the owner <strong>to</strong> the contrac<strong>to</strong>r and (ii) the terms<br />

incurred as a result of this guarantee. No representative,<br />

and conditions of warranty.<br />

owner notifies TRC of the need <strong>to</strong> repair roof leaks, (b) TRC is<br />

employee, agent of Tamko, or any other person has any authority The warranty may not be modified except in a writing signed by Tamko's unable <strong>to</strong> promptly inspect the roof, and © an emergency<br />

<strong>to</strong> assume for Tamko any additional or other liability or<br />

president. No representative, employee, agent of Tamko or any person, other than condition exists that requires immediate repair <strong>to</strong> avoid<br />

the president of Tamko, has any authority <strong>to</strong> assume for Tamko any additional or<br />

responsibility. Tamko shall not be responsible for or liable if there other liability or responsibility.<br />

substantial damage, owner may make immediate repair <strong>to</strong> avoid<br />

is any change or amendment <strong>to</strong> the Tamko built-up roof<br />

Warranty is not valid in Hawaii, Alaska and California. A separate limited substantial damage <strong>to</strong> owner, and owner may make temporary<br />

specification, unless such change or amendment is approved in warranty is available for products used in California. Products are sold "as is" and repairs as may be essential and such action shall not be a<br />

"with all faults" when used outside of the 48 contiguous United States.<br />

writing by Tamko.<br />

No action for breach of this limited warranty shall be brought later than one year breach of warranty.<br />

after any cause of action has accrued.<br />

See item 14 above.<br />

27 Executed by owner No Yes; owner is <strong>to</strong> sign and retain warranty with the contrac<strong>to</strong>r's receipt for<br />

future reference.<br />

No<br />

813


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Tremco, Inc. Tremco, Inc. Trenco, Inc.<br />

2 Title, original publication date, “10 Year QA Plus Warranty For New <strong>Roof</strong>s;” July 17, 2000 “15 Year QA Plus Warranty For New <strong>Roof</strong>s;” July 17, 2000 “5 Year QA Plus Warranty For Res<strong>to</strong>red <strong>Roof</strong>s;” July 17, 2000<br />

and identifying symbol, if any<br />

3 Product, specification, or Therm 100, Therm 200, Burmastic 100, Burmastic 200, BUR Therm 100, Therm 200, Burmastic 100, Burmastic 200, BUR Res<strong>to</strong>ration of built-up roofs and modified bitumen roofs<br />

system covered Combinations; PowerPly MB Systems, HP 4510, TremFast Combinations; PowerPly MB Systems, HP 4510; TremFast<br />

4 Scope of coverage Material and workmanship; Tremco warrants that it will repair Material and workmanship; Tremco warrants that it will repair Material and workmanship; Tremco warrants that it will repair<br />

leaks and provide roof inspections, preventive maintenance, and leaks and provide roof inspections, preventive maintenance, and leaks caused by defects in workmanship or material of the<br />

limited housekeeping services on the Tremco <strong>Roof</strong>ing System limited housekeeping services on the Tremco <strong>Roof</strong>ing System res<strong>to</strong>ration project and provide roof inspections, preventive<br />

(TRS) in years two (2) and five (5). (See Special (TRS) in years two (2), five (5) and ten (10). (See Special maintenance and limited housekeeping services on the<br />

Features/Conditions). TRS shall be defined as the Features/Conditions). TRS shall be defined as the Res<strong>to</strong>red <strong>Roof</strong>ing System (RRS) in year two (2). (See Special<br />

weatherproofing assembly and its components, which include the weatherproofing assembly and its components, which include the Features/Conditions). Warranty does not include recoating of<br />

membrane, insulation, flashings, all sheet metal-related details, membrane, insulation, flashings, all sheet metal-related details, roof membranes. Warranty is intended <strong>to</strong> extend the life of the<br />

and termination details as specified by Tremco. Warranty does and termination details as specified by Tremco. Warranty does existing roof.<br />

not include recoating of roof membranes.<br />

not include recoating of roof membranes.<br />

5 Length of coverage 10 years 15 years 5 years<br />

6 Nature of remedy Tremco will repair leaks in the roofing system and provide the Tremco will repair leaks in the roofing system and provide the Tremco will repair leaks in the res<strong>to</strong>red roofing system and<br />

inspection, preventive maintenance and housekeeping services inspection, preventive maintenance and housekeeping services provide the inspection, preventive maintenance and<br />

prescribed in the warranty in years two and five. Tremco will prescribed in the warranty in years two, five and ten. Tremco will housekeeping services prescribed in the warranty in year two.<br />

provide roof inspection reports. provide roof inspection reports. Tremco will provide roof inspection reports. If complete roof<br />

replacement is required during the warranty period, Tremco will<br />

refund the entire res<strong>to</strong>ration contract amount. Refunded<br />

amount <strong>to</strong> be applied <strong>to</strong>ward a new Tremco roof system.<br />

7 Monetary limitations Total liability of Tremco and any affiliate over the life of the Total liability of Tremco and any affiliate over the life of the Total liability of Tremco and any affiliate over the life of the<br />

warranty shall not exceed in dollar value the installed contract warranty shall not exceed in dollar value the installed contract warranty shall not exceed in dollar value the installed contract<br />

price of the TRS; Tremco’s <strong>to</strong>tal liability shall be pro-rated on a price of the TRS; Tremco’s <strong>to</strong>tal liability shall be pro-rated on a price of the res<strong>to</strong>red roof system; Tremco’s <strong>to</strong>tal liability shall be<br />

straight line basis over the life of the warranty and Tremco’s straight line basis over the life of the warranty and Tremco’s pro-rated on a straight line basis over the life of the warranty<br />

liability shall not exceed such pro-rated amount. liability shall not exceed such pro-rated amount. and Tremco’s liability shall not exceed such pro-rated amount.<br />

8 Notification requirements Owner shall report all leaks by contacting Tremco at 1-800-422- Owner shall report all leaks by contacting Tremco at 1-800-422- Owner shall report all leaks by contacting Tremco at 1-800-422-<br />

1195 or by writing <strong>to</strong> Tremco at 3735 Green Road, Beachwood, 1195 or by writing <strong>to</strong> Tremco at 3735 Green Road, Beachwood, 1195 or by writing <strong>to</strong> Tremco at 3735 Green Road, Beachwood,<br />

Ohio 44122, as soon as possible (however, in no event more than Ohio 44122, as soon as possible (however, in no event more than Ohio 44122, as soon as possible (however, in no event more<br />

thirty (30) days) after leakage is or should have been discovered. thirty (30) days) after leakage is or should have been discovered. than thirty (30) days) after leakage is or should have been<br />

discovered.<br />

9 Exclusive or additional Remedies and obligations stated in warranty are the sole and exclusive Remedies and obligations stated in warranty are the sole and exclusive Remedies and obligations stated in warranty are the sole and exclusive<br />

remedy remedies and obligations <strong>to</strong> the owner for any and all matters arising with remedies and obligations <strong>to</strong> the owner for any and all matters arising with remedies and obligations <strong>to</strong> the owner for any and all matters arising with<br />

respect <strong>to</strong> or in any way connected with the TRS, or its component products, respect <strong>to</strong> or in any way connected with the TRS, or its component products, respect <strong>to</strong> or in any way connected with the roof res<strong>to</strong>ration system, or its<br />

or any goods or services related there<strong>to</strong>. Warranty is in lieu of any and all or any goods or services related there<strong>to</strong>. Warranty is in lieu of any and all component products, or any goods or services related there<strong>to</strong>. Warranty<br />

other warranties, obligations or agreements, and any rights or remedies other warranties, obligations or agreements, and any rights or remedies is in lieu of any and all other warranties, obligations or agreements, and<br />

against any person or entity under the Uniform Commercial Code or against any person or entity under the Uniform Commercial Code or any rights or remedies against any person or entity under the Uniform<br />

otherwise with respect <strong>to</strong> the sale of goods and/or services. Neither Tremco otherwise with respect <strong>to</strong> the sale of goods and/or services. Neither Tremco Commercial Code or otherwise with respect <strong>to</strong> the sale of goods and/or<br />

or any affiliate shall be liable for any damages which are based upon or any affiliate shall be liable for any damages which are based upon services. Neither Tremco or any affiliate shall be liable for any damages<br />

negligence, breach of warranty, strict liability or any other theory of liability negligence, breach of warranty, strict liability or any other theory of liability which are based upon negligence, breach of warranty, strict liability or<br />

other than the exclusive liability set forth in the warranty; excludes UCC other than the exclusive liability set forth in the warranty; excludes UCC any other theory of liability other than the exclusive liability set forth in the<br />

warranties. warranties. warranty; excludes UCC warranties<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral Neutral Tremco’s determination if complete roof replacement is required<br />

applicability<br />

during the warranty period due <strong>to</strong> a cause covered under the<br />

warranty.<br />

12 Specific exclusions from 1, 2, 3, 4, 7, 9, 11, 13, 16, 17, 18, 25 1, 2, 3, 4, 7, 9, 11, 13, 16, 17, 18, 25 1, 2, 3, 4, 7, 9, 11, 13, 16, 17, 18, 25<br />

coverage (see Item 12 in<br />

Introduction)<br />

13 Wind coverage/exclusions Tremco indicates that warranty covers roof damage resulting from Tremco indicates that warranty covers roof damage resulting from Tremco indicates that warranty covers roof damage resulting<br />

wind speeds up <strong>to</strong> 73 miles per hour. Warranty excludes wind speeds up <strong>to</strong> 73 miles per hour. Warranty excludes from wind speeds up <strong>to</strong> 73 miles per hour. Warranty excludes<br />

hurricane force winds (74 mph or greater) and <strong>to</strong>rnadoes. hurricane force winds (74 mph or greater) and <strong>to</strong>rnadoes. hurricane force winds (74 mph or greater) and <strong>to</strong>rnadoes.<br />

814


14 Specific conditions <strong>to</strong> make B, C, F, G, J, M, N, Q. Warranty may be voided by Tremco based B, C, F, G, J, M, N, Q. Warranty may be voided by Tremco based B, C, F, G, J, M, N, Q. Warranty may be voided by Tremco<br />

the warranty ineffective or on any event listed as an exclusion. (See Item 12 above). on any event listed as an exclusion. (See Item 12 above). based on any event listed as an exclusion. (See Item 12<br />

null and void (see Item 14 in<br />

above).<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain $10.00/square $15.00/square $5.00/square<br />

16 Minimum charge $1,000 $1,500 $500<br />

17 Ineligible structure or Single-family residential Single-family residential Single-family residential<br />

building use<br />

18 Pre-construction notice and None None None<br />

approval requirements<br />

19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy Tremco Technical Services makes on-site inspections prior, Tremco Technical Services makes on-site inspections prior, Tremco Technical Services makes on-site inspections prior,<br />

during and after application, as well as two years and five years during and after application, as well as two years and five years during and after application, as well as two years after issuance<br />

after issuance of warranty; no charge. after issuance of warranty; no charge of warranty; no charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

obligation for two years. for two years. deficiencies for two years.<br />

22 Backed by named insurance No; Tremco indicates that it maintains significant levels of product No; Tremco indicates that it maintains significant levels of product No; Tremco indicates that it maintains significant levels of<br />

or surety liability insurance covering its warranty obligations. liability insurance covering its warranty obligations. product liability insurance covering its warranty obligations.<br />

23 Issuing entity manufactures Tremco manufactures and sells the product. Tremco manufactures and sells the product. Tremco manufactures and sells the product.<br />

and/or sells products<br />

24 Conditions for renewal or Warranty can be renewed for five years at a charge of Warranty can be renewed for five years at a charge of No renewal provision<br />

extension $5.00/square, with a $500 minimum charge $5.00/square, with a $500 minimum charge.<br />

25 Assignability Owner’s rights under warranty are not transferable. Owner’s rights under warranty are not transferable. Owner’s rights under warranty are not transferable.<br />

26 Special features/condition Preventive maintenance services are repairing of tears, splits, and Preventive maintenance services are repairing of tears, splits, and Preventive maintenance services are repairing of tears, splits,<br />

breaks in metal edge flashing components, flashing membrane breaks in metal edge flashing components, flashing membrane and breaks in metal edge flashing components, flashing<br />

and roof membrane with appropriate repair mastics and and roof membrane with appropriate repair mastics and membrane and roof membrane with appropriate repair mastics<br />

membranes. Exposed fasteners will be sealed. Termination bar membranes. Exposed fasteners will be sealed. Termination bar and membranes. Exposed fasteners will be sealed.<br />

and counterflashings will be sealed. Splits and blisters which and counterflashings will be sealed. Splits and blisters which Termination bar and counterflashings will be sealed. Splits and<br />

threaten the roof integrity will be cleaned, primed, and repaired threaten the roof integrity will be cleaned, primed, and repaired blisters which threaten the roof integrity will be cleaned, primed,<br />

with appropriate repair mastics and membranes. Metal projections with appropriate repair mastics and membranes. Metal projections and repaired with appropriate repair mastics and membranes.<br />

(hoods and clamps) will be sealed. (hoods and clamps) will be sealed. Metal projections (hoods and clamps) will be sealed.<br />

<strong>Roof</strong> inspection services are visual inspection of the roof <strong>Roof</strong> inspection services are visual inspection of the roof <strong>Roof</strong> inspection services are visual inspection of the roof<br />

membrane, roof surface conditions and the flashing systems membrane, roof surface conditions and the flashing systems membrane, roof surface conditions and the flashing systems<br />

including, but not limited <strong>to</strong>, the metal edge system, base flashings including, but not limited <strong>to</strong>, the metal edge system, base flashings including, but not limited <strong>to</strong>, the metal edge system, base<br />

on equipment and adjoining walls, counterflashings and on equipment and adjoining walls, counterflashings and flashings on equipment and adjoining walls, counterflashings<br />

termination details, soil stacks and vents, and inspection of roof<strong>to</strong>p termination details, soil stacks and vents, and inspection of roof<strong>to</strong>p and termination details, soil stacks and vents, and inspection of<br />

projections, and equipment including, but not limited <strong>to</strong>, pitch projections, and equipment including, but not limited <strong>to</strong>, pitch roof<strong>to</strong>p projections, and equipment including, but not limited <strong>to</strong>,<br />

pans, HVAC equipment, sky lights, and access hatches. pans, HVAC equipment, sky lights, and access hatches. pitch pans, HVAC equipment, sky lights, and access hatches.<br />

General roof<strong>to</strong>p housekeeping services are removal of General roof<strong>to</strong>p housekeeping services are removal of General roof<strong>to</strong>p housekeeping services are removal of<br />

incidental debris and disposal at the Owner’s approved on-site incidental debris and disposal at the Owner’s approved on-site incidental debris and disposal at the Owner’s approved on-site<br />

location. location. location.<br />

Owner is responsible for keeping effluent and debris from the Owner is responsible for keeping effluent and debris from the Owner is responsible for keeping effluent and debris from the<br />

roof surface. Cus<strong>to</strong>mer production-related materials are excluded roof surface. Cus<strong>to</strong>mer production-related materials are excluded roof surface. Cus<strong>to</strong>mer production-related materials are<br />

as part of the housekeeping if Tremco’s standard scheduled as part of the housekeeping if Tremco’s standard scheduled excluded as part of the housekeeping if Tremco’s standard<br />

housekeeping is insufficient <strong>to</strong> maintain the integrity of the roofing housekeeping is insufficient <strong>to</strong> maintain the integrity of the roofing scheduled housekeeping is insufficient <strong>to</strong> maintain the integrity<br />

system. Additionally, if scheduled cleaning is insufficient <strong>to</strong> system. Additionally, if scheduled cleaning is insufficient <strong>to</strong> of the roofing system. Additionally, if scheduled cleaning is<br />

maintain the roof integrity, Owner must pay for additional maintain the roof integrity, Owner must pay for additional insufficient <strong>to</strong> maintain the roof integrity, Owner must pay for<br />

cleaning/inspections or assume responsibility for such cleanings. cleaning/inspections or assume responsibility for such cleanings. additional cleaning/inspections or assume responsibility for such<br />

Owner shall provide waivers of subrogation upon request. Any Owner shall provide waivers of subrogation upon request. Any cleanings.<br />

unresolved issues under the warranty shall be submitted <strong>to</strong> the unresolved issues under the warranty shall be submitted <strong>to</strong> the Owner shall provide waivers of subrogation upon request.<br />

exclusive jurisdiction of the courts of Cuyahoga County, Ohio and exclusive jurisdiction of the courts of Cuyahoga County, Ohio and Any unresolved issues under the warranty shall be submitted <strong>to</strong><br />

governed by Ohio law. governed by Ohio law. the exclusive jurisdiction of the courts of Cuyahoga County,<br />

Ohio and governed by Ohio law.<br />

27 Executed by owner No; warranty states that owner agrees that the warranty, services No; warranty states that owner agrees that the warranty, services No; warranty states that owner agrees that the warranty,<br />

and remedies set forth in the warranty are exclusive. and remedies set forth in the warranty are exclusive. services and remedies set forth in the warranty are exclusive.<br />

815


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity Tremco Incororated U.S Intec U. S. Intec Inc.<br />

2 Title, original publication “10 Year QA Plus Warranty For Res<strong>to</strong>red <strong>Roof</strong>s;” July 17, 2000 “U.S. Intec LMG - Labor and Material Guarantee (A limited “No Dollar Limit (NDL) Guarantee;” February, 1999; USICS100<br />

date, and identifying symbol, warranty);” April, 2000; USICS 104 4/00 2/99<br />

if any<br />

3 Product, specification, or Res<strong>to</strong>ration of built-up roofs and modified bitumen roofs Modified bitumen specifications: Brai Supreme APP Smooth, APP Granule, Modified bitumen specifications: All Brai Supreme APP, Brai<br />

system covered APP Granule FR, SBS Granule, SBS Poly Granule FR, SBS Glass Granule Supreme SBS, and Brai Supreme Plus SBS Products<br />

FR, SBS Poly Smooth, SBS Glass Base, and Brai Supreme Plus SBS Poly<br />

Granule FR<br />

4 Scope of coverage Material and workmanship; Tremco warrants that it will repair leaks caused Material only: U.S. Intec roof membrane and U.S. Intec base Material and workmanship; U.S. Intec guarantees that it will make those<br />

by defects in workmanship or material of the res<strong>to</strong>ration project and provide flashing materials will withstand ordinary wear and tear by the repairs <strong>to</strong> the U.S. Intec roofing membrane, base flashing, insulation,<br />

roof inspections, preventive maintenance and limited housekeeping services elements and will be free from manufacturing defects which affect expansion joint covers and pre-flashed accessories as are necessary <strong>to</strong><br />

on the Res<strong>to</strong>red <strong>Roof</strong>ing System (RRS) in years two (2) and five (5). (See their ability <strong>to</strong> maintain the roof in watertight condition. correct leaks resulting from (1) natural deterioration of the U.S. Intec<br />

Special Features/Conditions). Warranty does not include recoating of roof<br />

roofing materials; (2) blisters; (3) bare spots; (4) fish-mouths; (5) ridges;<br />

membranes. Warranty is intended <strong>to</strong> extend the life of the existing roof.<br />

(6) splits not caused by structural failure or movement of or cracks in the<br />

substrate roof base or non-U.S. Intec insulation over which the U.S. Intec<br />

roofing materials are applied; (7) buckles and wrinkles; (8) workmanship<br />

in applying the U.S. Intec roofing materials; and (9) slippage of<br />

membrane or base flashing.<br />

5 Length of coverage 10 years 12 years 5, 10, 12, 15 or 20 years. Duration of coverage depends on<br />

membrane, system configuration, and contrac<strong>to</strong>r status.<br />

6 Nature of remedy Tremco will repair leaks in the res<strong>to</strong>red roofing system and provide U.S. Intec’s sole responsibility is <strong>to</strong> repair that portion of the U.S. U.S. Intec guarantees that it will make those repairs <strong>to</strong> the U.S.<br />

the inspection, preventive maintenance and housekeeping Intec materials that contains manufacturing defects or Intec roofing membrane, base flashing, insulation, expansion<br />

services prescribed in the warranty in years two and five. Tremco deterioration caused by ordinary wear and tear by the elements joint covers and pre-flashed accessories as are necessary <strong>to</strong><br />

will provide roof inspection reports. If complete roof replacement that have resulted in a roof leak. U.S. Intec shall resolve claims correct leaks.<br />

is required during the first five years, Tremco will refund the entire within 90 days after notification of a leak.<br />

res<strong>to</strong>ration contract amount; after five years, the maximum amount<br />

refunded will be 50% of the res<strong>to</strong>ration contract amount which will<br />

be decreased by 10% per year for the balance of the warranty.<br />

Refunded amounts may only be applied <strong>to</strong>ward a new Tremco roof<br />

system.<br />

7 Monetary limitations Total liability of Tremco and any affiliate over the life of the None stated None stated<br />

warranty shall not exceed in dollar value the installed contract<br />

price of the res<strong>to</strong>red roof system; Tremco’s <strong>to</strong>tal liability shall be<br />

pro-rated on a straight line basis over the life of the warranty and<br />

Tremco’s liability shall not exceed such pro-rated amount.<br />

8 Notification requirements Owner shall report all leaks by contacting Tremco at 1-800-422- Written notice within 30 days after discovery of the leak <strong>to</strong> U.S. Written notice within 30 days after discovery of the leak <strong>to</strong> U.S.<br />

1195 or by writing <strong>to</strong> Tremco at 3735 Green Road, Beachwood, Intec Contrac<strong>to</strong>r Services Department, 1361 Alps Road, Bldg. 7-B, Intec Contrac<strong>to</strong>r Services Department, 1361 Alps Road, Bldg. 7-<br />

Ohio 44122, as soon as possible (however, in no event more than Wayne, New Jersey 07470. Notice <strong>to</strong> the roofing contrac<strong>to</strong>r is not B, Wayne, New Jersey 07470. Notice <strong>to</strong> the roofing contrac<strong>to</strong>r<br />

thirty (30) days) after leakage is or should have been discovered. notice <strong>to</strong> U.S. Intec. Notice must include a copy of the warranty or is not notice <strong>to</strong> U.S. Intec.<br />

proof of purchase of U.S. Intec roof membrane and U.S. Intec<br />

base flashing materials.<br />

9 Exclusive or additional Remedies and obligations stated in warranty are the sole and exclusive Warranty is expressly in lieu of any other guarantees or warranties Guarantee is expressly in lieu of any other guarantees or warranties, and<br />

remedy remedies and obligations <strong>to</strong> the owner for any and all matters arising with and of any other obligations or liability on the part of U.S. Intec, any other obligations or liability on the part of U.S. Intec whether any<br />

respect <strong>to</strong> or in any way connected with the roof res<strong>to</strong>ration system, or its whether any claim is based upon strict liability, negligence, breach claim is based upon strict liability, negligence, breach of warranty or any<br />

component products, or any goods or services related there<strong>to</strong>. Warranty is of warranty, or any other theory or cause of action; excludes UCC other theory or cause of action; excludes UCC warranties.<br />

in lieu of any and all other warranties, obligations or agreements, and any warranties.<br />

rights or remedies against any person or entity under the Uniform<br />

Commercial Code or otherwise with respect <strong>to</strong> the sale of goods and/or<br />

services. Neither Tremco or any affiliate shall be liable for any damages<br />

which are based upon negligence, breach of warranty, strict liability or any<br />

other theory of liability other than the exclusive liability set forth in the<br />

warranty; excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Tremco’s determination if complete replacement is required during Neutral (no provision) Neutral (no provision)<br />

applicability<br />

the warranty period due <strong>to</strong> a cause covered under the warranty.<br />

816


12 Specific exclusions from 1, 2, 3, 4, 7, 9, 11, 13, 16, 17, 18, 25 1, 2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 13 (including aliphatic or aromatic 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15, 17, 22.<br />

coverage (see Item 12 in<br />

solvents, chlorinated hydrocarbons, turpentine, oils, organic or<br />

Introduction) inorganic polar materials), 15, 17, 19, 20, 22.<br />

13 Wind coverage/exclusions Tremco indicates that warranty covers roof damage resulting from Warranty excludes winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. U.S. Warranty excludes winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. U.S.<br />

wind speeds up <strong>to</strong> 73 miles per hour. Warranty excludes Intec indicates that there is no coverage for damage caused by Intec indicates that there is no coverage for damage caused by<br />

hurricane force winds (74 mph or greater) and <strong>to</strong>rnadoes. wind wind<br />

14 Specific conditions <strong>to</strong> make B, C, F, G, J, M, N, Q. Warranty may be voided by Tremco based Warranty states that cancellation of the warranty will result if the C, M. Warranty states that cancellation of this guarantee will result if the<br />

the warranty ineffective or on any event listed as an exclusion. (See Item 12 above). roof is damaged by any cause listed as an exclusion (See Item 12 roof is damaged by any cause listed as an exclusion (See Item 12 above)<br />

null and void (see Item 14 in above) if the damage affects the integrity or watertightness of the if the damage affects the integrity or watertightness of the roof and if the<br />

Introduction) roof. owner does not promptly make repairs following written notification by<br />

U.S. Intec <strong>to</strong> rectify the damage and preserve the integrity of the roof.<br />

15 Cost <strong>to</strong> obtain $10.00/square None 10 years: no charge; 12 years: no charge; 15 years: $10/square<br />

(for Brai Supreme SBS); 20 years: $15/square (for Brai<br />

Supreme SBS)<br />

16 Minimum charge $1,000 None None<br />

17 Ineligible structure or Single-family residential Cannot have high internal humidity, or be used as freezer buildings for cold U.S. Intec states <strong>to</strong> consult the U.S. Intec Application and<br />

building use s<strong>to</strong>rage. U.S. Intec indicates that the U.S. Intec application and Specification Manual<br />

specification manual lists other ineligible structures or building uses.<br />

18 Pre-construction notice and None None Contrac<strong>to</strong>r provides notice <strong>to</strong> U.S. Intec through submittal prior<br />

approval requirements<br />

<strong>to</strong> job start.<br />

19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy Tremco Technical Services makes on-site inspections prior, No on-site inspections U.S. Intec technical field representative makes on-site<br />

during and after application, as well as two years after issuance of<br />

inspection prior <strong>to</strong> application and after completion prior <strong>to</strong><br />

warranty; no charge.<br />

issuance of warranty and two-years after issuing warranty; no<br />

charge.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship deficiencies None; material-only warranty Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> materials and<br />

obligation for two years. workmanship for 2 years after completion of the roof.<br />

22 Backed by named insurance No; Tremco indicates that it maintains significant levels of product No No<br />

or surety<br />

liability insurance covering its warranty obligations.<br />

23 Issuing entity manufactures Tremco manufactures and sells the product. U.S. Intec manufactures and sells product U.S. Intec manufactures and sells product.<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability Owner’s rights under warranty are not transferable. Not transferable or assignable in any manner. Guarantee is assignable <strong>to</strong> another owner of the building for the<br />

remaining term if the following conditions are met: (1) the request is in<br />

writing within 30 days after ownership transfer; (2) the membrane is<br />

inspected and any requested repairs are completed at owner’s expense;<br />

(3) the proposed assignment is approved in writing by an authorized U.S.<br />

Intec Contrac<strong>to</strong>r Services Manager; and (4) an assignment fee of $500 is<br />

paid <strong>to</strong> U.S. Intec. Guarantee is not otherwise assignable, directly or<br />

indirectly.<br />

26 Special features/condition Preventive maintenance services are repairing of tears, splits, and breaks in metal edge Owner must follow a maintenance program in accordance with the Owner must perform regular inspections and maintenance during the guarantee<br />

flashing components, flashing membrane and roof membrane with appropriate repair mastics instructions stated on the reverse side of the warranty, including inspecting and perform repairs identified during inspections by U.S. Intec as necessary <strong>to</strong><br />

and membranes. Exposed fasteners will be sealed. Termination bar and counterflashings the roof at least twice a year, arranging for repairs <strong>to</strong> correct non- preserve the integrity of the U.S. Intec roofing materials.<br />

will be sealed. Splits and blisters which threaten the roof integrity will be cleaned, primed, and guaranteed conditions, re-attaching loose metalwork, replacing sealant and Owner shall, at its expense, remove (and, if desired, subsequently replace)<br />

repaired with appropriate repair mastics and membranes. Metal projections (hoods and re-coating any cracked, flaking, blistered or worm (sic) areas with a any materials and equipment that impede inspection and repair of the U.S. Intec<br />

clamps) will be sealed. compatible U.S. Intec coating. Coatings over smooth-surfaced products roofing material, such as HVAC units and satellite dishes mounted so that there is<br />

<strong>Roof</strong> inspection services are visual inspection of the roof membrane, roof surface must be maintained <strong>to</strong> protect the membrane surface. no functional access <strong>to</strong> the roof system, and precast concrete or rubber pavers,<br />

conditions and the flashing systems including, but not limited <strong>to</strong>, the metal edge system, base Owner must sign and mail <strong>to</strong> U.S. Intec the warranty registration form wood decking and steel grating that are installed over the U.S. Intec roofing<br />

flashings on equipment and adjoining walls, counterflashings and termination details, soil within 120 days of roof completion in order for warranty <strong>to</strong> be effective. No materials.<br />

stacks and vents, and inspection of roof<strong>to</strong>p projections, and equipment including, but not representative, employee, or agent of U.S. Intec, or any other person, has In an emergency, Owner may authorize or perform temporary repairs <strong>to</strong><br />

limited <strong>to</strong>, pitch pans, HVAC equipment, sky lights, and access hatches. any authority <strong>to</strong> assume for U.S. Intec any additional or other liability or minimize damage <strong>to</strong> the building or its contents. Such work will not result in the<br />

General roof<strong>to</strong>p housekeeping services are removal of incidental debris and disposal at responsibility. U.S. Intec shall not be responsible for any changes <strong>to</strong> the cancellation of the guarantee provided that the temporary repairs are reasonable<br />

the Owner’s approved on-site location. U.S. Intec specifications applicable <strong>to</strong> the roof unless the change is and cus<strong>to</strong>mary, and do not result in permanent damage <strong>to</strong> the U.S. Intec roofing<br />

Owner is responsible for keeping effluent and debris from the roof surface. Cus<strong>to</strong>mer approved in writing by an authorized U.S. Intec Contrac<strong>to</strong>r Services materials. Owner is responsible for all expenses associated with temporary<br />

production-related materials are excluded as part of the housekeeping if Tremco’s standard Manager. repairs.<br />

scheduled housekeeping is insufficient <strong>to</strong> maintain the integrity of the roofing system.<br />

In no event shall new penetrations be covered under the terms of the<br />

Additionally, if scheduled cleaning is insufficient <strong>to</strong> maintain the roof integrity, Owner must pay<br />

guarantee.<br />

for additional cleaning/inspections or assume responsibility for such cleanings.<br />

No representative, employee, or agent of U.S. Intec, or any other person, has<br />

Owner shall provide waivers of subrogation upon request. Any unresolved issues under<br />

any authority <strong>to</strong> assume for U.S. Intec any additional or other liability or<br />

the warranty shall be submitted <strong>to</strong> the exclusive jurisdiction of the courts of Cuyahoga County,<br />

responsibility in connection with the roof. U.S. Intec shall not be responsible for<br />

Ohio and governed by Ohio law.<br />

or liable for any change or amendment <strong>to</strong> the U.S. Intec roof specifications in<br />

regard <strong>to</strong> the construction of the roof, unless the change or amendment <strong>to</strong> the<br />

specifications is approved in writing by an authorized U.S. Intec Contrac<strong>to</strong>r<br />

Services Manager<br />

27 Executed by owner No; warranty states that owner agrees that the warranty, services Yes (See Special Features/Conditions). No<br />

and remedies set forth in the warranty are exclusive.<br />

817


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity U.S. Intec, Inc. U.S. Intec, Inc. U.S. Intec, Inc.<br />

2 Title, original publication “Commercial <strong>Roof</strong> Guarantee;” May, 2000; USICS101 5/00 “Ten Year Limited Warranty on Material;” June, 1999; USICS201 U.S. Intec, Inc. <strong>Roof</strong>ing and Waterproofing Products Full Value<br />

date, and identifying symbol,<br />

6/99 Warranty"; 1995.<br />

if any<br />

3 Product, specification, or Modified bitumen specifications: All Brai Supreme APP, Brai Modified bitumen specifications: Brai Supreme APP Smooth, Brai For modified bitumen specifications using SP-4, GBSP-4,<br />

system covered Supreme SBS, and Brai Supreme Plus SBS Products Supreme SBS, Poly Smooth, and Brai Supreme SBS Glass Base GBSP-4FR, GBSP-250FR or Intec Flex membranes, see the<br />

U.S. Intec, Inc. Modified Bitumen <strong>Roof</strong>ing Systems manual for<br />

details.<br />

4 Scope of coverage Material and workmanship; U.S. Intec guarantees that it will make those Material only: U.S. Intec modified bitumen roof membrane and Material and workmanship (See Special Features/Conditions); U.S. Intec<br />

repairs <strong>to</strong> the U.S. Intec roofing membrane, base flashing, insulation, base flashing materials will withstand ordinary wear and tear by guarantees it will repair or replace, at its sole discretion, the Intec roofing<br />

expansion joint covers and pre-flashed accessories as are necessary <strong>to</strong><br />

the elements and will be free of manufacturing defects which affect<br />

membranes and base flashings, as is necessary <strong>to</strong> correct leaks resulting<br />

correct leaks resulting from (1) natural deterioration of the U.S. Intec roofing<br />

from (a) manufacturing defects; (2) deterioration as a result of ordinary<br />

their ability <strong>to</strong> maintain the roof in watertight condition.<br />

materials; (2) blisters; (3) bare spots; (4) fish-mouths; (5) ridges; (6) splits<br />

wear and tear from exposure <strong>to</strong> the elements; (3) splits, fissures, or tears<br />

not caused by structural failure or movement of or cracks in the substrate not caused by structural or roof deck movement or failure; and (4)<br />

roof base or non-U.S. Intec insulation over which the U.S. Intec roofing<br />

workmanship in installing the roofing membrane and base flashing.<br />

materials are applied; (7) buckles and wrinkles; (8) workmanship in applying<br />

the U.S. Intec roofing materials; and (9) slippage of membrane or base<br />

flashing.<br />

5 Length of coverage 5, 10, 12, 15 or 20 years. Duration of coverage depends on 10 years 10, 12, 15 or 20 years (Length of coverage depends on<br />

membrane, system configuration, and contrac<strong>to</strong>r status.<br />

membrane, system configuration and contrac<strong>to</strong>r status).<br />

6 Nature of remedy U.S. Intec guarantees that it will make those repairs <strong>to</strong> the U.S. U.S. Intec’s sole responsibility is the repair or replacement, at U.S.<br />

Intec roofing membrane, base flashing, insulation, expansion joint Intec’s option, of that portion of the U.S. Intec roof membrane and<br />

covers and pre-flashed accessories as are necessary <strong>to</strong> correct base flashing materials that contain manufacturing defects or<br />

leaks<br />

deterioration caused by ordinary wear and tear by the elements<br />

that have resulted in a roof leak.<br />

7 Monetary limitations U.S. Intec inserts a dollar per square maximum liability over the U.S. Intec’s maximum liability for cost of repairs or replacement during the None stated.<br />

life of the guarantee upon issuance of the guarantee.<br />

first year after completion is the original cost of the U.S. Intec roof<br />

membrane and base flashing materials only. After the first year, U.S. Intec’s<br />

maximum liability is the original cost of the U.S. Intec roof membrane and<br />

base flashing materials used on the roof reduced by 10% of the maximum<br />

liability during each year after the first year of the warranty, less any costs<br />

previously incurred by U.S. Intec for repair or replacement during previous<br />

years. In no event shall U.S. Intec be liable for a sum greater than the<br />

maximum liability of the warranty or for more than 5 times the proportional<br />

cost paid <strong>to</strong> the company for the U.S. Intec roof membrane and base<br />

flashing materials installed on the affected portion of the roof, whichever is<br />

less.<br />

U.S. Intec will repair or replace, at its sole discretion, the Intec<br />

roofing membranes, covered roof accessories and base flashings, or<br />

portion thereof, as is necessary <strong>to</strong> correct leaks. During first two<br />

years, Intec shall have no obligation <strong>to</strong> repair any leaks due <strong>to</strong><br />

misapplication.<br />

8 Notification requirements Written notice within 30 days after discovery of the leak <strong>to</strong> U.S. Intec Written notice within 30 days after discovery of the leak <strong>to</strong> the Written notice <strong>to</strong> U.S. Intec within 15 days of discovering<br />

nearest U.S. Intec district office.<br />

Contrac<strong>to</strong>r Services Department, 1361 Alps Road, Bldg. 7-B, Wayne, New<br />

Jersey 07470. Notice <strong>to</strong> the roofing contrac<strong>to</strong>r is not notice <strong>to</strong> U.S. Intec.<br />

conditions which are the basis of a warranty claim against U.S.<br />

Intec.<br />

9 Exclusive or additional Guarantee is expressly in lieu of any other guarantees or warranties, and Warranty is expressly in lieu of any other guarantees or<br />

Remedy set forth in warranty shall be the sole and exclusive remedy<br />

remedy<br />

any other obligation or liability on the part of U.S. Intec whether any claim is warranties, and any other obligations or liability on the part of U.S. available <strong>to</strong> owner. Guarantee is in lieu of any other guarantees or<br />

based upon strict liability, negligence, breach of warranty or any other<br />

Intec whether any claim is based upon strict liability, negligence,<br />

warranties, and any other obligation or liability on the part of U.S. Intec<br />

theory or cause of action; excludes UCC warranties.<br />

whether any claim is based upon strict liability, negligence, breach of<br />

breach of warranty or any other theory or cause of action; excludes<br />

warranty or any other theory or cause of action; excludes UCC<br />

UCC warranties.<br />

warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (no provision) Neutral (no provision) U.S. Intec's determination<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15, 17, 22. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 (including aliphatic or 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 13, 15, 17, 22.<br />

coverage (see Item 12 in<br />

aromatic solvents, chlorinated hydrocarbons, turpentine, oils, Warranty states that Specific Condition H also makes the<br />

Introduction)<br />

organic or inorganic polar materials), 15, 17, 19, 20, 22<br />

warranty inapplicable.<br />

13 Wind coverage/exclusions Warranty excludes winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. U.S. Warranty excludes winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. U.S. Warranty excludes winds<strong>to</strong>rms, hurricanes, and <strong>to</strong>rnadoes.<br />

Intec indicates that there is no coverage for damage caused by Intec indicates that there is no coverage for damage caused by U.S. Intec indicates that there is no coverage for damage<br />

wind. wind. caused by wind.<br />

818


14 Specific conditions <strong>to</strong> make C, M. Warranty states that cancellation of this guarantee will result if the C, H. Warranty states that cancellation of this warranty will result C, G, H, I, L, M<br />

the warranty ineffective or roof is damaged by any cause listed as an exclusion (See Item 12 above) if if the roof is damaged by any cause listed as an exclusion (See<br />

the damage affects the integrity or watertightness of the roof and if the<br />

null and void (see Item 14 in<br />

Item 12 above) so as <strong>to</strong> affect the integrity or watertightness of the<br />

owner does not promptly make repairs following written notification by U.S.<br />

Introduction)<br />

roof.<br />

Intec <strong>to</strong> rectify the damage and preserve the integrity of the roof.<br />

15 Cost <strong>to</strong> obtain 5 years: $4.00/square; 10 years: $6.00/square; None 10 yrs: no charge; 12 yrs: no charge; 15 yrs: $10.00/sq (for<br />

12 years: $7.00/square; 15 years: $9.00/square; Intec Flex); 20 years: $15.00/sq (for Intec Flex)<br />

20 years: $12.00/square<br />

16 Minimum charge 5 years: $350; 10 years: $500; 12 years: $500 None 10 yrs: no charge; 12 yrs: no charge;<br />

15 years: $500; 20 years: $500 15 yrs: $1,000; 20 yrs: $1,500.<br />

17 Ineligible structure or U.S. Intec states <strong>to</strong> consult the U.S. Intec, Inc. Application and Warranty does not apply <strong>to</strong> application over cold s<strong>to</strong>rage or freezer See U.S. Intec's specification manual<br />

building use<br />

Specification Manual<br />

buildings or buildings with high humidity conditions. U.S. Intec indicates<br />

that the U.S. Intec application and specification manual lists other ineligible<br />

structures or building uses.<br />

18 Pre-construction notice and Contrac<strong>to</strong>r provides notice <strong>to</strong> U.S. Intec through submittal prior <strong>to</strong> None Contrac<strong>to</strong>r provides notice <strong>to</strong> U.S. Intec through submittal or<br />

approval requirements job start. prior <strong>to</strong> job start.<br />

19 Approved, authorized, or Yes No Yes<br />

licensed requirements<br />

20 Job inspection policy U.S. Intec technical field representative makes on-site inspection No on-site inspections.<br />

prior <strong>to</strong> application and after completion prior <strong>to</strong> issuance of<br />

warranty and two-years after issuing warranty; no charge.<br />

U.S. Intec technical field representatives may make periodic on-site inspections<br />

prior <strong>to</strong> and during application. Technical field representative performs on-site<br />

inspection after completion prior <strong>to</strong> issuance of warranty; no charge.<br />

U.S. Intec may at its option make an inspection of the roofing system during<br />

the period between 23 and 25 months after validation of the guarantee and<br />

protect the Owner and contrac<strong>to</strong>r with a report detailing any application related<br />

inadequacies or leaks in the membrane or base flashing.<br />

21 Contrac<strong>to</strong>r’s post-installation Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> materials and None; material-only warranty Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> all leaks and<br />

obligation workmanship for 2 years after completion of the roof. workmanship deficiencies for 2 years after the completion of the<br />

roof.<br />

22 Backed by named insurance No No No; U.S. Intec indicates that it carries product liability insurance<br />

or surety<br />

covering its guarantee obligations.<br />

23 Issuing entity manufactures U.S. Intec manufactures and sells product. U.S. Intec manufactures and sells product. U.S. Intec manufactures and sells product.<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability Guarantee is assignable <strong>to</strong> another owner of the building for the remaining<br />

term if the following conditions are met: (1) the request is in writing within 30<br />

days after ownership transfer; (2) the membrane is inspected and any<br />

requested repairs are completed at owner’s expense; (3) the proposed<br />

assignment is approved in writing by an authorized U.S. Intec Contrac<strong>to</strong>r<br />

Services Manager; and (4) an assignment fee of $500 is paid <strong>to</strong> U.S. Intec.<br />

Guarantee is not otherwise assignable, directly or indirectly.<br />

Not transferable or assignable in any manner<br />

Guarantee is assignable <strong>to</strong> another owner of the building if the following<br />

conditions are met: (1) The request is sent by certified mail <strong>to</strong> U.S. Intec, Inc.,<br />

Attn: Contrac<strong>to</strong>rs Services Department, 1361 Alps Rd.., Wayne, NJ 07470 within<br />

30 days after ownership transfer; (2) the membrane is inspected by Intec and any<br />

required repairs are completed at the owner's expense; (3) the proposed<br />

assignment is approved in writing by an authorized Intec Contrac<strong>to</strong>r Services<br />

Manager; and (4) an assignment fee of $750 is paid <strong>to</strong> Intec. Guarantee is not<br />

otherwise transferable or assignable, directly or indirectly.<br />

26 Special features/condition Owner must perform regular inspections and maintenance during the guarantee and perform Owner must sign and mail <strong>to</strong> U.S. Intec the warranty registration<br />

repairs identified during inspections by U.S. Intec as necessary <strong>to</strong> preserve the integrity of the<br />

U.S. Intec roofing materials.<br />

form within 30 days of completion of the roof for the warranty <strong>to</strong> be<br />

Owner shall, at its expense, remove (and, if desired, subsequently replace) any materials effective.<br />

and equipment that impede inspection and repair of the U.S. Intec roofing material, such as<br />

No representative, employee, or agent of U.S. Intec, or any<br />

HVAC units and satellite dishes mounted so that there is no functional access <strong>to</strong> the roof<br />

Warranty states that owner and roofing contrac<strong>to</strong>r expressly agree that if the owner<br />

discovers or should have discovered within the first two years leaks in the membrane or<br />

base flashings due <strong>to</strong> misapplication or <strong>to</strong> the roofer's failure <strong>to</strong> install the membrane and<br />

base flashings in compliance with the Intec specification manual in effect at the time the<br />

roof was installed, it is the roofing contrac<strong>to</strong>r's sole responsibility <strong>to</strong> repair those leaks and<br />

Intec shall have no obligation <strong>to</strong> repair any such leaks.<br />

system, and precast concrete or rubber pavers, wood decking and steel grating that are other person, has any authority <strong>to</strong> assume for the company any If Intec determines after inspection that a complaint is expressly excluded by the terms of<br />

installed over the U.S. Intec roofing materials.<br />

additional or other liability or responsibility. U.S. Intec shall not be<br />

the guarantee, Owner shall be responsible for reimbursing Intec for the reasonable costs<br />

In an emergency, Owner may authorize or perform temporary repairs <strong>to</strong> minimize damage associated with making the inspection. If the Owner fails <strong>to</strong> reimburse U.S. Intec within 30<br />

<strong>to</strong> the building or its contents. Such work will not result in the cancellation of the guarantee responsible for or liable for any change and/or amendment <strong>to</strong> the days of receipt of an invoice, U.S. Intec's guarantee obligations are terminated. If the<br />

provided that the temporary repairs are reasonable and cus<strong>to</strong>mary, and do not result in U.S. Intec roof specifications in regard <strong>to</strong> the construction of the inspection occurs within the first two years after validation of the guarantee, the<br />

permanent damage <strong>to</strong> the U.S. Intec roofing materials. Owner is responsible for all expenses<br />

reimbursable expenses are the just obligation of the Owner and roofing contrac<strong>to</strong>r.<br />

associated with temporary repairs. roof unless the change and/or amendment <strong>to</strong> the specifications I f Intec discovers conditions in the Intec membrane or base<br />

In no event shall new penetrations be covered under the terms of the guarantee. are approved in writing by an authorized U.S. Intec Contrac<strong>to</strong>r Lashing or adjacent <strong>to</strong> the roof system that are not covered by the guarantee but which<br />

No representative, employee, or agent of U.S. Intec, or any other person, has any authority<br />

Services Manager<br />

have effected or may effect the __ integrity of the Intec roofing membrane or base<br />

<strong>to</strong> assume for U.S. Intec any additional or other liability or responsibility in connection with the<br />

flashings,<br />

roof. U.S. Intec shall not be responsible for or liable for any change or amendment <strong>to</strong> the Owner agrees <strong>to</strong> completely remedy the conditions within 30 days after notice from<br />

U.S. Intec roof specifications in regard <strong>to</strong> the construction of the roof, unless the change or<br />

Intec, weather permitting. Owner shall send an inspection report <strong>to</strong> Intec detailing such<br />

amendment <strong>to</strong> the specifications is approved in writing by an authorized U.S. Intec Contrac<strong>to</strong>r<br />

repairs within 15 days of their completion. Owner may make essential emergency<br />

Services Manager.<br />

temporary repairs at Owner's expense. Owner's failure <strong>to</strong> comply with terms and<br />

conditions should immediately terminate Intec's obligations under the guarantee .in full<br />

without further notice.<br />

27 Executed by owner No Yes (See Special Features/Conditions.) No<br />

819


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity U. S. Intec Inc. U. S. Intec Inc. U. S. Intec Inc.<br />

2 Title, original publication “Intec/Permaglass Ten Year Limited Warranty on Material;” June, “U.S. Intec Limited Warranty on Material - Twelve Year;” June, “No Dollar Limit (NDL) Guarantee;” February, 1999; USICS100<br />

date, and identifying symbol, 1999; USICS200 6/99 1999; USICS202 6/99 2/99<br />

if any<br />

3 Product, specification, or All Intec/Permaglass specifications Modified bitumen specifications: Brai Supreme APP Granule, Brai Modified bitumen specifications: All Brai Supreme APP, Brai<br />

system covered Supreme APP Granule FR, SBS Granule, SBS Poly Granule FR, Supreme SBS, and Brai Supreme Plus SBS Products<br />

SBS Glass Granule FR<br />

4 Scope of coverage Material only: Intec/Permaglass fiberglass roof membrane and Material only: U.S. Intec modified bitumen roof membrane and<br />

base flashing materials will withstand ordinary wear and tear by base flashing materials will withstand ordinary wear and tear by<br />

the elements and will be free of manufacturing defects which affect the elements and will be free of manufacturing defects which affect<br />

their ability <strong>to</strong> maintain the roof in watertight condition.<br />

their ability <strong>to</strong> maintain the roof in watertight condition.<br />

Material and workmanship; U.S. Intec guarantees that it will make those<br />

repairs <strong>to</strong> the U.S. Intec roofing membrane, base flashing, insulation,<br />

expansion joint covers and pre-flashed accessories as are necessary <strong>to</strong><br />

correct leaks resulting from (1) natural deterioration of the U.S. Intec<br />

roofing materials; (2) blisters; (3) bare spots; (4) fish-mouths; (5) ridges;<br />

(6) splits not caused by structural failure or movement of or cracks in the<br />

substrate roof base or non-U.S. Intec insulation over which the U.S. Intec<br />

roofing materials are applied; (7) buckles and wrinkles; (8) workmanship<br />

in applying the U.S. Intec roofing materials; and (9) slippage of<br />

membrane or base flashing.<br />

5 Length of coverage 10 years 12 years 5, 10, 12, 15 or 20 years. Duration of coverage depends on<br />

membrane, system configuration, and contrac<strong>to</strong>r status.<br />

6 Nature of remedy U.S. Intec’s sole responsibility is the repair or replacement, at U.S. U.S. Intec’s sole responsibility is the repair or replacement, at U.S. U.S. Intec guarantees that it will make those repairs <strong>to</strong> the U.S.<br />

Intec’s option, of that portion of the U.S. Intec roof membrane and Intec’s option, of that portion of the U.S. Intec roof membrane and Intec roofing membrane, base flashing, insulation, expansion<br />

base flashing materials that contain manufacturing defects or base flashing materials that contain manufacturing defects or joint covers and pre-flashed accessories as are necessary <strong>to</strong><br />

deterioration caused by ordinary wear and tear by the elements deterioration caused by ordinary wear and tear by the elements correct leaks.<br />

that have resulted in a roof leak<br />

that have resulted in a roof leak.<br />

7 Monetary limitations U.S. Intec’s maximum liability for cost of repairs or replacement during the U.S. Intec’s maximum liability for cost of repairs or replacement during the None stated<br />

first year after completion is the original cost of the U.S. Intec roof<br />

first year after completion is the original cost of the U.S. Intec roof<br />

membrane and base flashing materials only. After the first year, U.S. Intec’s membrane and base flashing materials only. After the first year, U.S. Intec’s<br />

maximum liability is the original cost of the U.S. Intec roof membrane and maximum liability is the original cost of the U.S. Intec roof membrane and<br />

base flashing materials used on the roof reduced by 10% of the maximum base flashing materials used on the roof reduced by 8.34% of the maximum<br />

liability during each year after the first year of the warranty, less any costs liability during each year after the first year of the warranty, less any costs<br />

previously incurred by U.S. Intec for repair or replacement during previous previously incurred by U.S. Intec for repair or replacement during previous<br />

years. In no event shall U.S. Intec be liable for a sum greater than the years. In no event shall U.S. Intec be liable for a sum greater than the<br />

maximum liability of the warranty or for more than 5 times the proportional maximum liability of the warranty or for more than 5 times the proportional<br />

cost paid <strong>to</strong> the company for the U.S. Intec roof membrane and base cost paid <strong>to</strong> the company for the U.S. Intec roof membrane and base<br />

flashing materials installed on the affected portion of the roof, whichever is flashing materials installed on the affected portion of the roof, whichever is<br />

less.<br />

less.<br />

8 Notification requirements Written notice within 30 days after discovery of the leak <strong>to</strong> the Written notice within 30 days after discovery of the leak <strong>to</strong> the Written notice within 30 days after discovery of the leak <strong>to</strong> U.S.<br />

nearest U.S. Intec district office. nearest U.S. Intec district office. Intec Contrac<strong>to</strong>r Services Department, 1361 Alps Road, Bldg. 7-<br />

B, Wayne, New Jersey 07470. Notice <strong>to</strong> the roofing contrac<strong>to</strong>r<br />

is not notice <strong>to</strong> U.S. Intec.<br />

9 Exclusive or additional Warranty is expressly in lieu of any other guarantees or<br />

Warranty is expressly in lieu of any other guarantees or warranties, and any<br />

remedy<br />

warranties, and any other obligations or liability on the part of U.S. other obligations or liability on the part of U.S. Intec whether any claim is<br />

Intec whether any claim is based upon strict liability, negligence,<br />

based upon strict liability, negligence, breach of warranty or any other<br />

theory or cause of action; excludes UCC warranties.<br />

breach of warranty or any other theory or cause of action; excludes<br />

UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Neutral (No provision) Neutral (No provision) Neutral (no provision)<br />

applicability<br />

Guarantee is expressly in lieu of any other guarantees or warranties, and<br />

any other obligations or liability on the part of U.S. Intec whether any<br />

claim is based upon strict liability, negligence, breach of warranty or any<br />

other theory or cause of action; excludes UCC warranties.<br />

12 Specific exclusions from 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 (including aliphatic or 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 (including aliphatic or 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15, 17, 22.<br />

coverage (see Item 12 in aromatic solvents, chlorinated hydrocarbons, turpentine, oils, aromatic solvents, chlorinated hydrocarbons, turpentine, oils,<br />

Introduction)<br />

organic or inorganic polar materials), 15, 17, 19, 20, 22. organic or inorganic polar materials), 15, 17, 19, 20, 22.<br />

13 Wind coverage/exclusions Warranty excludes winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. U.S. Warranty excludes winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. U.S. Warranty excludes winds<strong>to</strong>rms, hurricanes and <strong>to</strong>rnadoes. U.S.<br />

Intec indicates that there is no coverage for damage caused by Intec indicates that there is no coverage for damage caused by Intec indicates that there is no coverage for damage caused by<br />

wind. wind. wind<br />

820


14 Specific conditions <strong>to</strong> make C, H. Warranty states that cancellation of this warranty will result C, H. Warranty states that cancellation of this warranty will result C, M. Warranty states that cancellation of this guarantee will<br />

the warranty ineffective or if the roof is damaged by any cause listed as an exclusion (See if the roof is damaged by any cause listed as an exclusion (See result if the roof is damaged by any cause listed as an exclusion<br />

null and void (see Item 14 in Item 12 above) so as <strong>to</strong> affect the integrity or watertightness of the Item 12 above) so as <strong>to</strong> affect the integrity or watertightness of the (See Item 12 above) if the damage affects the integrity or<br />

Introduction) roof. roof. watertightness of the roof and if the owner does not promptly<br />

make repairs following written notification by U.S. Intec <strong>to</strong> rectify<br />

the damage and preserve the integrity of the roof.<br />

15 Cost <strong>to</strong> obtain None None 10 years: no charge; 12 years: no charge; 15 years: $10/square<br />

(for Brai Supreme SBS); 20 years: $15/square (for Brai<br />

Supreme SBS)<br />

16 Minimum charge None None None<br />

17 Ineligible structure or Warranty does not apply <strong>to</strong> application over cold s<strong>to</strong>rage or freezer Warranty does not apply <strong>to</strong> application over cold s<strong>to</strong>rage or freezer U.S. Intec states <strong>to</strong> consult the U.S. Intec Application and<br />

building use buildings or buildings with high humidity conditions. U.S. Intec buildings or buildings with high humidity conditions. U.S. Intec Specification Manual<br />

indicates that the U.S. Intec application and specification manual indicates that the U.S. Intec application and specification manual<br />

lists other ineligible structures or building uses.<br />

lists other ineligible structures or building uses.<br />

18 Pre-construction notice and None None Contrac<strong>to</strong>r provides notice <strong>to</strong> U.S. Intec through submittal prior<br />

approval requirements<br />

<strong>to</strong> job start.<br />

19 Approved, authorized, or No No Yes<br />

licensed requirements<br />

20 Job inspection policy No on-site inspections. No on-site inspections. U.S. Intec technical field representative makes on-site<br />

inspection prior <strong>to</strong> application and after completion prior <strong>to</strong><br />

issuance of warranty and two-years after issuing warranty; no<br />

charge.<br />

21 Contrac<strong>to</strong>r’s post-installation None; material-only warranty None; material-only warranty Contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> materials and<br />

obligation<br />

workmanship for 2 years after completion of the roof.<br />

22 Backed by named insurance No No No<br />

or surety<br />

23 Issuing entity manufactures U.S. Intec manufactures and sells product. U.S. Intec manufactures and sells product. U.S. Intec manufactures and sells product.<br />

and/or sells products<br />

24 Conditions for renewal or No renewal provision No renewal provision No renewal provision<br />

extension<br />

25 Assignability Not transferable or assignable in any manner Not transferable or assignable in any manner. Guarantee is assignable <strong>to</strong> another owner of the building for the<br />

remaining term if the following conditions are met: (1) the<br />

request is in writing within 30 days after ownership transfer; (2)<br />

the membrane is inspected and any requested repairs are<br />

completed at owner’s expense; (3) the proposed assignment is<br />

approved in writing by an authorized U.S. Intec Contrac<strong>to</strong>r<br />

Services Manager; and (4) an assignment fee of $500 is paid <strong>to</strong><br />

U.S. Intec. Guarantee is not otherwise assignable, directly or<br />

indirectly.<br />

26 Special features/condition Owner must sign and mail <strong>to</strong> U.S. Intec the warranty registration Owner must sign and mail <strong>to</strong> U.S. Intec the warranty registration Owner must perform regular inspections and maintenance during the guarantee<br />

form within 30 days of completion of the roof for the warranty <strong>to</strong> be form within 30 days of completion of the roof for the warranty <strong>to</strong> be and perform repairs identified during inspections by U.S. Intec as necessary <strong>to</strong><br />

effective. effective. preserve the integrity of the U.S. Intec roofing materials.<br />

No representative, employee, or agent of U.S. Intec, or any No representative, employee, or agent of U.S. Intec, or any Owner shall, at its expense, remove (and, if desired, subsequently replace)<br />

other person, has any authority <strong>to</strong> assume for the company any other person, has any authority <strong>to</strong> assume for the company any any materials and equipment that impede inspection and repair of the U.S. Intec<br />

additional or other liability or responsibility. U.S. Intec shall not be additional or other liability or responsibility. U.S. Intec shall not be roofing material, such as HVAC units and satellite dishes mounted so that there is<br />

responsible for or liable for any change and/or amendment <strong>to</strong> the responsible for or liable for any change and/or amendment <strong>to</strong> the no functional access <strong>to</strong> the roof system, and precast concrete or rubber pavers,<br />

U.S. Intec roof specifications in regard <strong>to</strong> the construction of the U.S. Intec roof specifications in regard <strong>to</strong> the construction of the wood decking and steel grating that are installed over the U.S. Intec roofing<br />

roof unless the change and/or amendment <strong>to</strong> the specifications roof unless the change and/or amendment <strong>to</strong> the specifications materials.<br />

are approved in writing by an authorized U.S. Intec Contrac<strong>to</strong>r are approved in writing by an authorized U.S. Intec Contrac<strong>to</strong>r In an emergency, Owner may authorize or perform temporary repairs <strong>to</strong><br />

Services Manager. Services Manager. minimize damage <strong>to</strong> the building or its contents. Such work will not result in the<br />

cancellation of the guarantee provided that the temporary repairs are reasonable<br />

and cus<strong>to</strong>mary, and do not result in permanent damage <strong>to</strong> the U.S. Intec roofing<br />

materials. Owner is responsible for all expenses associated with temporary<br />

repairs.<br />

In no event shall new penetrations be covered under the terms of the<br />

guarantee.<br />

No representative, employee, or agent of U.S. Intec, or any other person, has<br />

any authority <strong>to</strong> assume for U.S. Intec any additional or other liability or<br />

responsibility in connection with the roof. U.S. Intec shall not be responsible for<br />

or liable for any change or amendment <strong>to</strong> the U.S. Intec roof specifications in<br />

regard <strong>to</strong> the construction of the roof, unless the change or amendment <strong>to</strong> the<br />

specifications is approved in writing by an authorized U.S. Intec Contrac<strong>to</strong>r<br />

Services Manager<br />

27 Executed by owner Yes (See Special Features/Conditions.) Yes (See Special Features/Conditions.) No<br />

821


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

1 Identity of issuing entity<br />

Versico Incorporated, Versico Incorporated, Versico Incorporated,<br />

a subsidiary of Carlisle Companies a subsidiary of Carlisle Companies a subsidiary of Carlisle Companies<br />

2 Title, original publication Versico <strong>Roof</strong>ing System Warranty (With Extended Membrane “Versico Total <strong>Roof</strong>ing System Warranty”; June 1995 “Versico Total <strong>Roof</strong>ing System Warranty (With Extended<br />

date, and identifying symbol, Material Warranty); June 1995 Membrane Material Warranty)”; June 1995<br />

if any<br />

3 Product, specification, or VersiGard roofing systems, VersiWeld roofing systems VersiGard roofing systems, VersiWeld roofing systems VersiGard roofing systems, VersiWeld roofing systems<br />

system covered<br />

4 Scope of coverage Material and workmanship for initial 5 or 10 years; material-only for Material and workmanship; Versico warrants that it will repair leaks Material and workmanship for initial 10 or 15 years; material-only for as<br />

as long as 20 years. For initial term, Versico warrants it will repair in the Versico <strong>to</strong>tal roofing system caused by defects in the roofing long as 20 years. For initial term, Versico warrants it will repair leaks in<br />

leaks in the Versico roofing systems caused by defects in the system's material or workmanship of the Versico authorized the Versico <strong>to</strong>tal roofing system caused by defects in the roofing system's<br />

roofing system's material or workmanship of the Versico roofing contrac<strong>to</strong>r in installing the same. The Versico <strong>to</strong>tal roofing material or workmanship of the Versico authorized roofing contrac<strong>to</strong>r in<br />

authorized roofing contrac<strong>to</strong>r in installing the same. For the system is defined as the Versico membrane, flashings, adhesives installing the same. For the balance of 20 years, Versico will provide <strong>to</strong><br />

balance of 20 years, Versico will provide <strong>to</strong> the owner a credit <strong>to</strong> and sealants, fastener assemblies, metal edging, any Versico- the owner a credit <strong>to</strong> be applied <strong>to</strong>ward the purchase of new membrane<br />

be applied <strong>to</strong>ward the purchase of new membrane material in the brand products utilized in the installation, and any other products material in the event of premature deterioration of the Versico membrane<br />

event of premature deterioration of the Versico membrane specifically approved by Versico for coverage under warranty. material <strong>to</strong> the point of failure. The Versico <strong>to</strong>tal roofing system is<br />

material <strong>to</strong> the point of failure. The Versico roofing system is<br />

defined as the Versico membrane, flashings, adhesives and sealants, any<br />

defined as the Versico membrane, flashings, adhesives and<br />

other Versico-brand products utilized in the installation, and any other<br />

sealants, and any other Versico brand products utilized in the<br />

products specifically approved by Versico for coverage under the<br />

installation.<br />

warranty.<br />

5 Length of coverage 5 or 10 years material and workmanship; coverage for black 10 or 15 years; white VersiGard limited <strong>to</strong> 10 years 10 or 15 years material and workmanship; coverage for black<br />

VersiGard membrane material only can be extended up <strong>to</strong> 20 VeriGard membrane material only can be extended up <strong>to</strong> 20<br />

years.<br />

years.<br />

6 Nature of remedy For the initial 5- or 10-year term, the owner's remedies and Versi- The owner's remedies and Versico's liability shall be limited <strong>to</strong> For initial 10- or 15-year term, the owner's remedies and<br />

co's liability shall be limited <strong>to</strong> Versico's repair of the leak in the Versico's repair of the leak in the roofing system. Versico's liability shall be limited <strong>to</strong> Versico's repair of the leak in<br />

roofing system. For balance of 20 years, Versico will provide a<br />

the roofing system. For balance of 20 years, Versico will<br />

credit <strong>to</strong> be applied <strong>to</strong>ward the purchase of new membrane<br />

provide a credit <strong>to</strong> be applied <strong>to</strong>ward the purchase of new<br />

material, based on the number of remaining months of warranty<br />

membrane material, based on the number of remaining months<br />

and prorated at current prices.<br />

of warranty and prorated at current prices.<br />

7 Monetary limitations For 5- or 10-year material and workmanship warranty: no None stated. For 10- or 15-year material and workmanship warranty: no<br />

monetary limitation stated; extended warranty on membrane<br />

monetary limitation stated; extended warranty on membrane<br />

material: credit based on the number of remaining months of<br />

material: credit based on the number of remaining months of<br />

warranty and prorated at current prices.<br />

warranty and prorated at current prices.<br />

8 Notification requirements The owner shall provide Versico with written notice <strong>to</strong> Versico at The owner shall provide Versico with written notice <strong>to</strong> Versico at The owner shall provide Versico with written notice <strong>to</strong> Versico at<br />

3485 Fortuna Drive, Akron, OH 44312, within 30 days of the 3485 Fortuna Drive, Akron, OH 44312, within 30 days of the 3485 Fortuna Drive, Akron, OH 44312, within 30 days of the<br />

discovery of any leaks in the roofing system. discovery of any leaks in the roofing system. discovery of any leaks in the roofing system.<br />

9 Exclusive or additional Remedies stated in warranty are the sole and exclusive remedies Remedies stated in warranty are the sole and exclusive remedies Remedies stated in warranty are the sole and exclusive<br />

remedy for failure of the roofing system or its components; excludes UCC for failure of the roofing system or its components; excludes UCC remedies for failure of the roofing system or its components;<br />

warranties. warranties. excludes UCC warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Versico's determination Versico's determination Versico's determination<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4 (including damage by the building structure failing <strong>to</strong> 1, 2, 3, 4 (including damage by the building structure failing <strong>to</strong> 1, 2, 3, 4 (including damage by the building structure failing <strong>to</strong><br />

coverage (see Item 12 in have adequate strength <strong>to</strong> support all live and dead loads, have adequate strength <strong>to</strong> support all live and dead loads, have adequate strength <strong>to</strong> support all live and dead loads,<br />

Introduction) including water and snow loads), 9 (including recreational including water and snow loads), 9 (including recreational including water and snow loads), 9 (including recreational<br />

activities), 10, 11, 13, 16, 22. Warranty excludes damage caused activities), 10, 11, 13, 16, 22. Warranty excludes damage caused activities), 10, 11, 13, 16, 22. Warranty excludes damage<br />

by insects. by insects. caused by insects.<br />

13 Wind coverage/exclusions Versico indicates that warranty covers roof damage resulting from Versico indicates that warranty covers roof damage resulting from Versico indicates that warranty covers roof damage resulting<br />

wind speeds up <strong>to</strong> 55 mph. Warranty excludes winds in excess of wind speeds up <strong>to</strong> 55 mph. Warranty excludes winds in excess of from wind speeds up <strong>to</strong> 55 mph. Warranty excludes winds in<br />

55 mph measured at roof level and <strong>to</strong>rnadoes, without prior 55 mph measured at roof level and <strong>to</strong>rnadoes, without prior excess of 55 mph measured at roof level and <strong>to</strong>rnadoes, without<br />

approval from Versico. approval from Versico. prior approval from Versico.<br />

822


14 Specific conditions <strong>to</strong> make B (including taking of test cuts), C, F (including periodic cleaning B (including taking of test cuts), C, F (including periodic cleaning B (including taking of test cuts), C, F (including periodic cleaning<br />

the warranty ineffective or<br />

null and void (see Item 14 in<br />

Introduction)<br />

of drains and removal of harmful debris from roof), G of drains and removal of harmful debris from roof), G of drains and removal of harmful debris from roof), G<br />

15 Cost <strong>to</strong> obtain Manufacturer charges for this warranty; contact manufacturer Manufacturer charges for this warranty; contact manufacturer Manufacturer charges for this warranty; contact manufacturer<br />

directly for specific pricing information directly for specific pricing information directly for specific pricing information<br />

16 Minimum charge Manufacturer charges for this warranty; contact manufacturer Manufacturer charges for this warranty; contact manufacturer Manufacturer charges for this warranty; contact manufacturer<br />

directly for specific pricing information directly for specific pricing information directly for specific pricing information<br />

17 Ineligible structure or Single-family residences Single-family residences Single-family residences<br />

building use<br />

18 Pre-construction notice and The contrac<strong>to</strong>r is required <strong>to</strong> submit job approval forms before The contrac<strong>to</strong>r is required <strong>to</strong> submit job approval forms before The contrac<strong>to</strong>r is required <strong>to</strong> submit job approval forms before<br />

approval requirements project is authorized for warranty. project is authorized for warranty. project is authorized for warranty.<br />

19 Approved, authorized, or Yes Yes Yes<br />

licensed requirements<br />

20 Job inspection policy Versico inspec<strong>to</strong>r makes on-site inspection after completion, prior Versico inspec<strong>to</strong>r makes on-site inspection after completion, prior Versico inspec<strong>to</strong>r makes on-site inspection after completion,<br />

<strong>to</strong> issuance of warranty. <strong>to</strong> issuance of warranty. prior <strong>to</strong> issuance of warranty.<br />

21 Contrac<strong>to</strong>r’s post-installation The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

obligation deficiencies for two (2) years. deficiencies for two (2) years. deficiencies for two (2) years.<br />

22 Backed by named insurance No; Versico indicates that it does not carry insurance covering its No; Versico indicates that it does not carry insurance covering its No; Versico indicates that it does not carry insurance covering<br />

or surety warranty obligations. warranty obligations. its warranty obligations.<br />

23 Issuing entity manufactures Versico manufactures and sells product Versico manufactures and sells product Versico manufactures and sells product<br />

and/or sells products<br />

24 Conditions for renewal or For Verisgard Black <strong>Roof</strong>ing Systems only: 10 year warranty may For Verisgard Black <strong>Roof</strong>ing Systems only: 10 year warranty may For Verisgard Black <strong>Roof</strong>ing Systems only: 10 year warranty<br />

extension be extended for an additional 5 years. Owner’s must request be extended for an additional 5 years. Owner’s must request may be extended for an additional 5 years. Owner’s must<br />

Versico inspect reoof at the end of the first 10 years <strong>to</strong> determine if Versico inspect reoof at the end of the first 10 years <strong>to</strong> determine if request Versico inspect reoof at the end of the first 10 years <strong>to</strong><br />

any necessary modifications <strong>to</strong> the existing roof are required. The any necessary modifications <strong>to</strong> the existing roof are required. The determine if any necessary modifications <strong>to</strong> the existing roof are<br />

5 year extension will involve additional charges for the inspection 5 year extension will involve additional charges for the inspection required. The 5 year extension will involve additional charges<br />

and the extended warranty. and the extended warranty. for the inspection and the extended warranty.<br />

25 Assignability Warranty states that it is not assignable by operation of law or Warranty states that it is not assignable by operation of law or Warranty states that it is not assignable by operation of law or<br />

otherwise. Application may be made by a new building owner for otherwise. Application may be made by a new building owner for otherwise. Application may be made by a new building owner<br />

reissuance of the warranty during the original warranty period. reissuance of the warranty during the original warranty period. for reissuance of the warranty during the original warranty<br />

Certain procedures, including an inspection of the roofing system Certain procedures, including an inspection of the roofing system period. Certain procedures, including an inspection of the<br />

by Versico representative, and fees will apply <strong>to</strong> any reissuance. by Versico representative, and fees will apply <strong>to</strong> any reissuance. roofing system by Versico representative, and fees will apply <strong>to</strong><br />

Versico reserves the right, in its sole discretion, <strong>to</strong> refuse <strong>to</strong> Versico reserves the right, in its sole discretion, <strong>to</strong> refuse <strong>to</strong> any reissuance. Versico reserves the right, in its sole discretion,<br />

reissue this warranty. reissue this warranty. <strong>to</strong> refuse <strong>to</strong> reissue this warranty.<br />

26 Special features/condition By notifying Versico of a leak, the owner authorizes Versico <strong>to</strong> By notifying Versico of a leak, the owner authorizes Versico <strong>to</strong> By notifying Versico of a leak, the owner authorizes Versico <strong>to</strong><br />

investigate the cause of the leak. Should the investigation reveal investigate the cause of the leak. Should the investigation reveal investigate the cause of the leak. Should the investigation<br />

the cause of the leak <strong>to</strong> be outside the scope of the warranty, the cause of the leak <strong>to</strong> be outside the scope of the warranty, reveal the cause of the leak <strong>to</strong> be outside the scope of the<br />

investigation and repair costs shall be paid by owner investigation and repair costs shall be paid by owner warranty, investigation and repair costs shall be paid by owner<br />

27 Executed by owner No No No<br />

823


<strong>Roof</strong> Membrane Warranties (Built-Up, Modified Bitumen, and Single-Ply)<br />

Versico Incorporated,<br />

1 Identity of issuing entity a subsidiary of Carlisle CompaniesW.P. Hickman Systems, W.P. Hickman Systems, Inc. W.P. Hickman Systems, Inc.<br />

Inc.<br />

2 Title, original publication Versico <strong>Roof</strong>ing System Warranty; June 1995 Hickman <strong>Roof</strong>ing Systems Membrane Assemblies <strong>Roof</strong> Assemblies Guarantee January 1, 1980; GOES 447<br />

date, and identifying symbol, Guarantee; 1985; GOES 447<br />

if any<br />

3 Product, specification, or VersiGard roofing systems, VersiWeld roofing systems Built-up <strong>Roof</strong>ing Specifications; Modified Bitumen Specifisystem<br />

covered<br />

cations; Cold-Process BUR Specifications; Single-Ply<br />

Specifications<br />

4 Scope of coverage Material and workmanship; Versico warrants that it will repair leaks Material and workmanship; Hickman guarantees that it Material and workmanship; Hickman guarantees that it will<br />

in the Versico <strong>to</strong>tal roofing system caused by defects in the roofing will, at its expense, repair or cause <strong>to</strong> be repaired the repair or cause <strong>to</strong> be repaired leaks in the Hickman roof<br />

system's material or workmanship of the Versico authorized roofing system <strong>to</strong> an extent <strong>to</strong> return the system <strong>to</strong> a assembly.<br />

roofing contrac<strong>to</strong>r in installing the same. The Versico <strong>to</strong>tal roofing watertight condition.<br />

system is defined as the Versico membrane, flashings, adhesives<br />

and sealants, fastener assemblies, metal edging, any Versicobrand<br />

products utilized in the installation, and any other products<br />

specifically approved by Versico for coverage under warranty.<br />

5 Length of coverage 10 or 15 years 10 years 10 years<br />

6 Nature of remedy The owner's remedies and Versico's liability shall be limited <strong>to</strong> Hickman will take appropriate action <strong>to</strong> repair leaks that Hickman will inspect the roof and, if leak is covered under the<br />

Versico's repair of the leak in the roofing system. may occur due <strong>to</strong> ordinary wear that may be required guarantee, Hickman with at its own expense make or cause <strong>to</strong><br />

because of deficiencies resulting from workmanship be made all necessary repairs <strong>to</strong> the Hickman <strong>Roof</strong> Assembly <strong>to</strong><br />

during the membrane and flashing installation. Hickman's put it in<strong>to</strong> watertight condition.<br />

sole responsibility is the cost of repairs <strong>to</strong> the membrane<br />

assembly.<br />

7 Monetary limitations None stated. None stated. None stated.<br />

8 Notification requirements The owner shall provide Versico with written notice <strong>to</strong> Versico at Written notification within 10 days after discovery of a leak Written notification within 10 days after discovery of a leak on<br />

3485 Fortuna Drive, Akron, OH 44312, within 30 days of the on the roofing system or flashing assembly the roofing system or flashing assembly<br />

discovery of any leaks in the roofing system.<br />

9 Exclusive or additional Remedies stated in warranty are the sole and exclusive remedies Seeks <strong>to</strong> exclude and limit UCC implied warranties Seeks <strong>to</strong> exclude and limit UCC implied warranties<br />

remedy<br />

for failure of the roofing system or its components; excludes UCC<br />

warranties.<br />

10 Inclusion of consequential No No No<br />

damages<br />

11 Determination of warranty Versico's determination Neutral (no provision) Neutral (Hickman inspects roof)<br />

applicability<br />

12 Specific exclusions from 1, 2, 3, 4 (including damage by the building structure failing <strong>to</strong> 1, 2, 3, 4, 5, 6, 8, 10, 13, 17, 18, 22 1, 2, 3, 4, 5, 6, 8, 10, 13, 17, 18, 22<br />

coverage (see Item 12 in have adequate strength <strong>to</strong> support all live and dead loads,<br />

Introduction)<br />

including water and snow loads), 9 (including recreational<br />

activities), 10, 11, 13, 16, 22. Warranty excludes damage caused<br />

by insects.<br />

13 Wind coverage/exclusions Versico indicates that warranty covers roof damage resulting from Warranty excludes hurricane-related winds. Warranty Warranty excludes hurricane-related winds. Warranty covers<br />

wind speeds up <strong>to</strong> 55 mph. Warranty excludes winds in excess of covers roof damage resulting from wind speeds up <strong>to</strong> 73 roof damage resulting from wind speeds up <strong>to</strong> 73 miles per<br />

55 mph measured at roof level and <strong>to</strong>rnadoes, without prior miles per hour. hour.<br />

approval from Versico.<br />

14 Specific conditions <strong>to</strong> make B (including taking of test cuts), C, F (including periodic cleaning C C<br />

the warranty ineffective or of drains and removal of harmful debris from roof), G<br />

null and void (see Item 14 in<br />

Introduction)<br />

15 Cost <strong>to</strong> obtain Manufacturer charges for this warranty; contact manufacturer Varies based on system, contact manufacturer for pricing Varies based on system, contact manufacturer for pricing<br />

directly for specific pricing information information information<br />

824


16 Minimum charge Manufacturer charges for this warranty; contact manufacturer $500<br />

$500<br />

directly for specific pricing information<br />

17 Ineligible structure or Single-family residences Cold-s<strong>to</strong>rage, freezer, and dry kiln buildings; Hickman Cold-s<strong>to</strong>rage, freezer, and dry kiln buildings; Hickman reviews<br />

building use<br />

reviews all structures <strong>to</strong> determine eligibility.<br />

all structures <strong>to</strong> determine eligibility.<br />

18 Pre-construction notice and The contrac<strong>to</strong>r is required <strong>to</strong> submit job approval forms before Contrac<strong>to</strong>r required <strong>to</strong> give verbal or written notice <strong>to</strong> Contrac<strong>to</strong>r required <strong>to</strong> give verbal or written notice <strong>to</strong> schedule<br />

approval requirements project is authorized for warranty. schedule pre-job conference.<br />

pre-job conference.<br />

19 Approved, authorized, or Yes Yes<br />

Yes<br />

licensed requirements<br />

20 Job inspection policy Versico inspec<strong>to</strong>r makes on-site inspection after completion, prior Hickman field representative makes on-site inspections Hickman field representative makes on-site inspections prior <strong>to</strong>,<br />

<strong>to</strong> issuance of warranty.<br />

prior <strong>to</strong>, during, and after application as well as two years during, and after application as well as two years after<br />

after completion and makes yearly inspections; no completion and makes yearly inspections; no charge.<br />

charge.<br />

21 Contrac<strong>to</strong>r’s post-installation The contrac<strong>to</strong>r is obligated <strong>to</strong> make repairs <strong>to</strong> workmanship Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship Contrac<strong>to</strong>r obligated <strong>to</strong> make repairs <strong>to</strong> workmanship<br />

obligation deficiencies for two (2) years. deficiencies for two years<br />

deficiencies for two years<br />

22 Backed by named insurance No; Versico indicates that it does not carry insurance covering its<br />

or surety<br />

warranty obligations.<br />

No<br />

23 Issuing entity manufactures Versico manufactures and sells product. W.P. Hickmkan Systems, Inc. manufactures and sells the<br />

and/or sells products<br />

product.<br />

24 Conditions for renewal or For Verisgard Black <strong>Roof</strong>ing Systems only: 10 year warranty may Guarantees applicable <strong>to</strong> reroofing, retrofit, and new<br />

extension be extended for an additional 5 years. Owner’s must request construction projects can be renewed for 10 years; guarantees<br />

Versico inspect reoof at the end of the first 10 years <strong>to</strong> determine if<br />

applicable <strong>to</strong> res<strong>to</strong>ration projects can be renewed for five years.<br />

any necessary modifications <strong>to</strong> the existing roof are required. The<br />

Owner must notify Hickman 60 days prior <strong>to</strong> guarantee expira-<br />

5 year extension will involve additional charges for the inspection tion. Hickman representative makes inspection and notifies<br />

and the extended<br />

owner of all repairs required by Hickman. Owner pays for all<br />

repairs, which must be made with Hickman materials by an<br />

approved Hickman contrac<strong>to</strong>r. Upon completion and approval<br />

by Hickman of repairs and payment of guarantee charge,<br />

extended guarantee will be issued. Current cost for 5 or 10 year<br />

extension is $5.00/square.<br />

25 Assignability Warranty states that it is not assignable by operation of law or Transferable by the building owner <strong>to</strong> a subsequent Guarantee may be transferred by the building owner <strong>to</strong> a<br />

otherwise. Application may be made by a new building owner for purchaser of the property by giving not less than 10 days subsequent purchaser of the property by giving not less than ten<br />

reissuance of the warranty during the original warranty period. written notice <strong>to</strong> Hickman of proposed transfer; Hickman days written notice <strong>to</strong> Hickman of proposed transfer; Hickman<br />

Certain procedures, including an inspection of the roofing system<br />

will inspect roof and make written report <strong>to</strong> building owner and<br />

will inspect roofing system and make writ-ten report <strong>to</strong><br />

by Versico representative, and fees will apply <strong>to</strong> any reissuance.<br />

proposed purchaser of findings.<br />

Versico reserves the right, in its sole discretion, <strong>to</strong> refuse <strong>to</strong><br />

building owner and proposed purchaser of findings.<br />

reissue this warranty.<br />

26 Special features/condition By notifying Versico of leak, the owner authorizes Versico <strong>to</strong> To the extent any repairs <strong>to</strong> any part of the building other than<br />

investigate the cause of the leak. Should the investigation reveal<br />

the Hickman <strong>Roof</strong> Assembly are required, or the removal or<br />

the cause of the leak <strong>to</strong> be outside the scope of the warranty,<br />

replacement of any traffic surfaces or other appurtenances built<br />

investigation and repair costs shall be paid by owner.<br />

over the roof are required in order <strong>to</strong> put the Hickman <strong>Roof</strong><br />

Assembly in a watertight condition, the liability for or expense of<br />

any such repair, removal, or replacement shall be assumed and<br />

paid by the owner.<br />

27 Executed by owner No No<br />

No<br />

825


Section 6<br />

Incomplete Data


Index <strong>to</strong> Incomplete Data<br />

Incomplete Data<br />

Incomplete Data<br />

ALCM 833 FIELDS COMPANY, LLC 833<br />

7301 Bessemer Avenue 2240 Taylor Way<br />

Cleveland, OH 44127 Tacoma, WA 98421<br />

800556-8030 253/627-4098<br />

FAX: 216/341-5833 FAX: 253/383-2181<br />

E-mail: sales@alum.com<br />

E-mail:<br />

Web:<br />

Web:<br />

ALCO-NVC, INC. 833 GARDNER ASPHALT CORP/APOC DIV 833<br />

P.O. Box 14001 P.O. Box 5449<br />

Detroit, MI 48214 Tampa, FL 33675-6768<br />

800/323-0029 FAX: 813/248-6768<br />

FAX: 313/331-4726<br />

E-mail: alconvc@aol.com<br />

E-mail:<br />

Web: www.alconvc.com<br />

Web:<br />

BAKOR, Div of Henry Company 833 GARLAND COMPANY, INC. 833<br />

284 Watkline Road 3800 E. 91st Sreet<br />

Mississauga, ON L4Z 1P4 Cleveland, OH 44105<br />

CANADA 216/641-7500<br />

905/890-4800 FAX: 216/641-0633<br />

FAX: 905/890-4886<br />

E-mail:<br />

Web: www.bakor.com<br />

Web:<br />

CARLISLE SYNTEC INCORPORATEED 832 HONEYWELL INTERNATIONAL, INC. 834<br />

1285 Ritner Highway 2000 Regency Parkway, Suite 225<br />

P O Box 7000 Cary, NC 27511-8507<br />

Carlise, PA 17013 800/221-6490<br />

717/245-7000 FAX:<br />

FAX: 717/245-7053<br />

E-mail:<br />

Wev: www.carlislesyntec.com<br />

Web:<br />

CELOTEX CORP. 831 ICA, INC. 834<br />

4010 Boy Scout Blvd. P. O. Box 679<br />

Tampa, FL 33607 Warring<strong>to</strong>n, PA 18976<br />

813/873-1700 800/352-7002<br />

FAX: 813/873-4080 FAX: 215/918-0890<br />

E-mail:<br />

E-mail:<br />

Web:<br />

Web:<br />

CERTAINTEED / <strong>Roof</strong>ing Products 833 IKO INDUSTRIES 834<br />

750 E. Swedesford Road 120 Hay Road<br />

P O Box 860 Wilming<strong>to</strong>n, DE 19809<br />

Valley Forge, PA 19482 302/764-3100<br />

800/359-7298 FAX: 610/341-7055 FAX: 302/764-5852<br />

Web: www.certainteed.com<br />

E-mail:<br />

Web: www.iko.com<br />

ECOLOGY ROOF SYSTEMS 833 KARNAK CORPORATION 834<br />

505 N. Tustin Avenue #188 330 Central Avenue<br />

Santa Ana, CA 92705 Clark, NJ 07066<br />

714/972-1001 732/388-0300 800/526-4236<br />

FAX: 714/972-1079 FAX: 732/388-9422<br />

E-mail:<br />

E-mail:<br />

Web: www.ecologyroofsystem.com<br />

Web:<br />

829


Index <strong>to</strong> Incomplete Data<br />

Incomplete Data<br />

Incomplete Data<br />

MFM BUILDING PRODUCTS CORP. 834 REPUBLIC POWDERED METALS, INC. 833<br />

P.O.Box 340<br />

3735 Green Road<br />

520 Orange Street Beachwood, OH 44122<br />

Coshoc<strong>to</strong>n, OH 43812 800/551-7081<br />

704/622-2645 800/882-7663 FAX: 888/742-1759<br />

E-mail: mfm@coshoc<strong>to</strong>n.com<br />

E-mail:<br />

Web:<br />

Web:<br />

PERFORMANCE ROOF SYSTEMS, INC. 831 TEXSA, S.A. 834<br />

4821 Chelsea Avenue Poligono Can Pelegri<br />

Kansas City, MO 64130<br />

San Andreu de la Barca, Spain<br />

816/921-0221 34-3-6820770<br />

FAX: 816/921-5540 FAX: 34-3-6820752<br />

E-mail: prshunt@aol.com<br />

E-mail:<br />

Web:<br />

Web:<br />

POLYGLASS USA 831<br />

150 Lyon Drive 834<br />

Fernley, NV 89408<br />

702/575-6007<br />

FAX: 702/575-2314<br />

E-mail: cus<strong>to</strong>merservice@polyglass.com<br />

Web: www.polyglass.com<br />

830


Section 6: Incomplete Data<br />

In publishing the Low-Slope <strong>Roof</strong>ing Materials Guide, NRCA maintains a policy of <strong>to</strong>tal objectivity in its reporting of<br />

data. Nothing is required from listing manufacturers other than <strong>to</strong> adhere <strong>to</strong> the prescribed reporting format. Any<br />

manufacturer of a product in the product categories included in the Guide can be listed by submitting their<br />

information in accordance with procedures developed for this purpose.<br />

Product manufacturers included in the Guide are encouraged <strong>to</strong> provide NRCA with listing information for their<br />

products that is as complete as possible for publication in the Guide. Beginning with the 2000 edition of the Guide,<br />

in situations where manufacturers have submitted product information (e.g., test results) that is deemed <strong>to</strong> be<br />

incomplete, these specific products have been omitted from the detailed listing sections of the Guide. Manufacturers<br />

and products with incomplete product listing information are included in this new section of the Guide, entitled<br />

Section 6: Incomplete Data.<br />

NRCA has established this policy regarding manufacturers’ product listings with incomplete data at the request of<br />

users of the Guide, who are clearly seeking detailed and complete product information from the Guide and the<br />

companies listed.<br />

Users of the Guide who are interested in specific product information on a manufacturer’s product that is included in<br />

Section 6: Incomplete Data are encouraged <strong>to</strong> contact the specific product manufacturer directly. Manufacturers’<br />

contact information is provided in the index section of the Guide.<br />

For the 2001 edition of the Guide, incomplete product data was provided by the following manufacturers for the<br />

specific products indicated.<br />

ROOF COVERINGS (Section 1)<br />

Built-Up <strong>Roof</strong>ing<br />

Manufacturer<br />

Products<br />

None<br />

None<br />

Modified Bitumen<br />

Celotex Corporation<br />

Manufacturer<br />

Products<br />

SBS 170 Cap Sheet<br />

SBS 250 Cap Sheet<br />

SBS Dual-Ply FR Base Sheet<br />

SBS Dual-Ply FR Cap Sheet<br />

Performance <strong>Roof</strong> Systems Inc.<br />

Derbibase<br />

Polyglass USA, Inc.<br />

Elas<strong>to</strong>base Poly<br />

Modibase<br />

Polyall/Polyram<br />

Polyglass Base<br />

Polygram<br />

831


PVC<br />

Manufacturer<br />

Products<br />

None<br />

None<br />

EPDM<br />

Manufacturer<br />

Products<br />

None<br />

None<br />

CSPE<br />

Manufacturer<br />

Products<br />

None<br />

None<br />

PIB<br />

Manufacturer<br />

Products<br />

None<br />

None<br />

TPO<br />

Manufacturer<br />

Products<br />

Carlisle Syntec Incorporated<br />

Polyepichlorohydrin<br />

Other Prefabricated Sheet-Applied Membranes<br />

Manufacturer<br />

Products<br />

None<br />

None<br />

Spray Polyurethane Foam-Based Systems<br />

Manufacturer<br />

Products<br />

None<br />

None<br />

832


<strong>Roof</strong> Cements & Adhesives, and Coatings (Section 4)<br />

Manufacturer<br />

Products<br />

ALCM<br />

Asphalt Mastic Brush Grade<br />

Asphalt Mastic Trowel Grade<br />

Asphalt Mastic Brush Grade<br />

Asphalt Mastic Trowel Grade<br />

Asphalt Resaturant<br />

Asphalt <strong>Roof</strong> & Metal Coating – No Fiber<br />

Butyl Lastic<br />

Elasticote<br />

Glas-Mastic<br />

MBA Adhesive Brush Grade<br />

MBA Adhesive Trowel Grade<br />

Neoprene Rubber <strong>Roof</strong> Cement<br />

Pure Neoprene Rubber <strong>Roof</strong> Cement<br />

Seal-N-Save Aluminum Fibered<br />

Snow-Brite White Elas<strong>to</strong>meric<br />

1.2# Aluminum Non-Fibered<br />

1.3# Aluminum Fibered<br />

2.0# Aluminum Non-Fibered<br />

Alco-NVC, Inc.<br />

#218 White Latex Coating<br />

#218 White Elas<strong>to</strong>meric<br />

Gardner /Apoc<br />

APOC 103 Asphalt Primer<br />

APOC Neoprene Flash Cement<br />

Republic Powdered Metals<br />

Permaroof<br />

Southwestern Petroleum Corporation<br />

Flex Shield Patching Compound<br />

<strong>Roof</strong> Membrane Warranties (Section 5)<br />

Manufacturer<br />

Bakor - Division of Henry Company<br />

Certainteed / <strong>Roof</strong>ing Products<br />

Ecology <strong>Roof</strong> Systems<br />

Products<br />

No warranty information was provided for any<br />

product or system<br />

No warranty information was provided for any<br />

product or system<br />

No warranty information was provided for any<br />

product or system<br />

Fields Company, LLC<br />

Garland Company, Inc.<br />

No warranty information was provided for any<br />

product or system<br />

No warranty information was provided for any<br />

product or system<br />

833


<strong>Roof</strong> Membrane Warranties (Section 5)<br />

Manufacturer<br />

Honeywell International<br />

Products<br />

No warranty information was provided for any<br />

product or system<br />

ICA Inc.<br />

No warranty information was provided for any<br />

product or system<br />

IKO Industries<br />

No warranty information was provided for any<br />

product or system<br />

Karnak Corp.<br />

No warranty information was provided for any<br />

product or system<br />

MFM Building Products Corp.<br />

No warranty information was provided for any<br />

product or system<br />

Polyglass USA<br />

No warranty information was provided for any<br />

product or system<br />

Texsa, S.A.<br />

No warranty information was provided for any<br />

product or system<br />

834