VENTILATION<br />

The mine ventilati<strong>on</strong> is planned to c<strong>on</strong>sist of a fresh air fan atop <strong>the</strong> fresh air intake raise located<br />

to <strong>the</strong> near <strong>the</strong> western part of <strong>the</strong> ore body. The intake system will include <strong>the</strong> mine air fans<br />

and direct fired propane mine air heaters. The intake raise will also serve as a service raise for<br />

power lines and as an emergency escape way. The raise is planned to be driven at 50 degree<br />

dip such that a c<strong>on</strong>tinuous ladder from top to bottom can be installed as an emergency egress.<br />

The mine ventilati<strong>on</strong> air flow has been based up<strong>on</strong> <strong>the</strong> mine equipment fleet with an estimate of<br />

utilizati<strong>on</strong> and an additi<strong>on</strong>al allowance for losses and additi<strong>on</strong>al needs. The basis for <strong>the</strong><br />

estimate of 200,000 cfm (95 m 3 /sec) is summarized in Table 18-8.<br />

The NWT Mine Regulati<strong>on</strong>s (10.62(2)) require <strong>the</strong> provisi<strong>on</strong> of 0.06 m 3 /sec per KW of diesel<br />

powered equipment operating at <strong>the</strong> site. Scott Wils<strong>on</strong> RPA has estimated <strong>the</strong> amount of<br />

operating diesel equipment in its estimate of mine ventilati<strong>on</strong> air flow and based <strong>on</strong> <strong>the</strong>se<br />

estimates <strong>the</strong> 200,000 cfm exceeds <strong>the</strong> minimum requirements of <strong>the</strong> regulati<strong>on</strong>s. There are<br />

additi<strong>on</strong>al regulati<strong>on</strong>s related to <strong>the</strong> levels of carb<strong>on</strong> m<strong>on</strong>oxide and oxides of nitrogen in <strong>the</strong><br />

vicinity of <strong>the</strong> operator and in <strong>the</strong> undiluted equipment exhaust.<br />

Technical Report 43-101 – March 13, 2011 Page 18-22<br />