Chapter 4 Explanation of Functions<br />

4.2.21 Jump frequency function<br />

The jump frequency function allows you to operate the inverter so<br />

that it avoids the resonant frequency of the machine driven by the<br />

same.<br />

Since the inverter avoids the motor operation with a constant output<br />

frequency within the specified range of the frequencies to jump when<br />

the jump frequency function is enabled, you cannot set any inverter<br />

output frequency within the specified range of the frequencies to<br />

jump.<br />

Note that, while the inverter is accelerating or decelerating the motor, the inverter output frequency<br />

changes continuously according to the set acceleration/deceleration time.<br />

You can set up to three frequencies to jump.<br />

Item Function code Range of data Description<br />

Jump (center) frequency A063/A065/<br />

Setting of the center frequency of the<br />

0.00 to 400.0 (Hz) (*1)<br />

settings, 1st/2nd/3rd settings A067<br />

frequency range to be jumped<br />

Jump (hysteresis) frequency<br />

A064/A066/<br />

Setting of the half bandwidth of the<br />

width settings, 1st/2nd/3rd<br />

0.00 to 10.00(Hz)<br />

A068<br />

frequency range to be jumped<br />

settings<br />

*1 Setting of 0 Hz disables the jump frequency function.<br />

Output frequency<br />

Related code<br />

A063: Jump (center) frequency setting 1<br />

A064: Jump (hysteresis) frequency width<br />

setting 1<br />

A065: Jump (center) frequency setting 2<br />

A066: Jump (hysteresis) frequency width<br />

setting 2<br />

A067: Jump (center) frequency setting 3<br />

A068: Jump (hysteresis) frequency width<br />

setting 3<br />

A067<br />

A068<br />

A068<br />

A065<br />

A066<br />

A066<br />

A063<br />

A064<br />

A064<br />

4.2.22 Acceleration stop frequency setting<br />

The acceleration stop frequency setting function allows you to make<br />

the inverter wait, upon starting the motor, until the slipping of the<br />

motor becomes less when the load on the motor causes a large<br />

moment of inertia.<br />

Frequency command<br />

Related code<br />

A069: Acceleration stop frequency setting<br />

A070: Acceleration stop time frequency<br />

setting<br />

Use this function if the inverter has tripped because of overcurrent when starting the motor.<br />

This function can operate with every acceleration pattern, regardless of the setting of the acceleration<br />

curve selection (A097).<br />

Item Function code Range of data Description<br />

Acceleration stop frequency<br />

Setting of the frequency at which to<br />

A069 0.00 to 400.0(Hz)<br />

setting<br />

stop acceleration<br />

Acceleration stop time<br />

Setting of the length of time to stop<br />

A070<br />

0.0 to 60.0(s)<br />

frequency setting<br />

acceleration<br />

Output frequency<br />

A069<br />

A070<br />

Frequency command<br />

4 - 25